WorldWideScience

Sample records for magnetization transfer proportion

  1. Multistate cohort models with proportional transfer rates

    DEFF Research Database (Denmark)

    Schoen, Robert; Canudas-Romo, Vladimir

    2006-01-01

    of transfer rates. The two living state case and hierarchical multistate models with any number of living states are analyzed in detail. Applying our approach to 1997 U.S. fertility data, we find that observed rates of parity progression are roughly proportional over age. Our proportional transfer rate...... approach provides trajectories by parity state and facilitates analyses of the implications of changes in parity rate levels and patterns. More women complete childbearing at parity 2 than at any other parity, and parity 2 would be the modal parity in models with total fertility rates (TFRs) of 1.40 to 2......We present a new, broadly applicable approach to summarizing the behavior of a cohort as it moves through a variety of statuses (or states). The approach is based on the assumption that all rates of transfer maintain a constant ratio to one another over age. We present closed-form expressions...

  2. Which Mixed-Member Proportional Electoral Formula Fits You Best? Assessing the Proportionality Principle of Positive Vote Transfer Systems

    DEFF Research Database (Denmark)

    Bochsler, Daniel

    2014-01-01

    Mixed-member proportional systems (MMP) are a family of electoral systems which combine district-based elections with a proportional seat allocation. Positive vote transfer systems belong to this family. This article explains why they might be better than their siblings, and examines under which ...

  3. Magnetic field transfer device and method

    Science.gov (United States)

    Wipf, S.L.

    1990-02-13

    A magnetic field transfer device includes a pair of oppositely wound inner coils which each include at least one winding around an inner coil axis, and an outer coil which includes at least one winding around an outer coil axis. The windings may be formed of superconductors. The axes of the two inner coils are parallel and laterally spaced from each other so that the inner coils are positioned in side-by-side relation. The outer coil is outwardly positioned from the inner coils and rotatable relative to the inner coils about a rotational axis substantially perpendicular to the inner coil axes to generate a hypothetical surface which substantially encloses the inner coils. The outer coil rotates relative to the inner coils between a first position in which the outer coil axis is substantially parallel to the inner coil axes and the outer coil augments the magnetic field formed in one of the inner coils, and a second position 180[degree] from the first position, in which the augmented magnetic field is transferred into the other inner coil and reoriented 180[degree] from the original magnetic field. The magnetic field transfer device allows a magnetic field to be transferred between volumes with negligible work being required to rotate the outer coil with respect to the inner coils. 16 figs.

  4. Cross-domain transfer of quantitative discriminations: is it all a matter of proportion?

    Science.gov (United States)

    Balci, Fuat; Gallistel, Charles R

    2006-08-01

    Meck and Church (1983) estimated a 5:1 scale factor relating the mental magnitudes representing number to the mental magnitudes representing duration. We repeated their experiment with human subjects. We obtained transfer regardless of the objective scaling between the ranges; a 5:1 scaling for number versus duration (measured in seconds) was not necessary. We obtained transfer even when the proportions between the endpoints of the number range were different. We conclude that, at least in human subjects, transfer from a discrimination based on continuous quantity (duration) to a discrimination based on discrete quantity (number) is mediated by the cross-domain comparability of within-domain proportions. The results of our second and third experiments also suggest that the subjects compare a probe with a criterion determined by the range of stimuli tested rather than by trial-specific referents, in accordance with the pseudologistic model of Killeen, Fetterman, and Bizo (1997).

  5. The magnetic fluid for heat transfer applications

    International Nuclear Information System (INIS)

    Nakatsuka, K.; Jeyadevan, B.; Neveu, S.; Koganezawa, H.

    2002-01-01

    Real-time visual observation of boiling water-based and ionic magnetic fluids (MFs) and heat transfer characteristics in heat pipe using ionic MF stabilized by citrate ions (JC-1) as working liquid are reported. Irrespective of the presence or absence of magnetic field water-based MF degraded during boiling. However, the degradation of JC-1 was avoided by heating the fluid in magnetic field. Furthermore, the heat transfer capacity of JC-1 heat pipe under applied magnetic field was enhanced over the no field case

  6. Energy transfers and magnetic energy growth in small-scale dynamo

    KAUST Repository

    Kumar, Rohit Raj

    2013-12-01

    In this letter we investigate the dynamics of magnetic energy growth in small-scale dynamo by studying energy transfers, mainly energy fluxes and shell-to-shell energy transfers. We perform dynamo simulations for the magnetic Prandtl number Pm = 20 on 10243 grid using the pseudospectral method. We demonstrate that the magnetic energy growth is caused by nonlocal energy transfers from the large-scale or forcing-scale velocity field to small-scale magnetic field. The peak of these energy transfers moves towards lower wave numbers as dynamo evolves, which is the reason why the integral scale of the magnetic field increases with time. The energy transfers U2U (velocity to velocity) and B2B (magnetic to magnetic) are forward and local. Copyright © EPLA, 2013.

  7. Wireless power transfer magnetic couplers

    Science.gov (United States)

    Wu, Hunter; Gilchrist, Aaron; Sealy, Kylee

    2016-01-19

    A magnetic coupler is disclosed for wireless power transfer systems. A ferrimagnetic component is capable of guiding a magnetic field. A wire coil is wrapped around at least a portion of the ferrimagnetic component. A screen is capable of blocking leakage magnetic fields. The screen may be positioned to cover at least one side of the ferrimagnetic component and the coil. A distance across the screen may be at least six times an air gap distance between the ferrimagnetic component and a receiving magnetic coupler.

  8. Mass Transfer Process by Magneto-convection at a Solid-liquid Interface in a Heterogeneous Vertical Magnetic Field

    Science.gov (United States)

    Sugiyama, Atsushi; Morisaki, Shigeyoshi; Aogaki, Ryoichi

    2003-08-01

    When an external magnetic field is vertically imposed on a solid-liquid interface, the mass transfer process of a solute dissolving from or depositing on the interface was theoretically examined. In a heterogeneous vertical magnetic field, a material receives a magnetic force in proportion to the product of the magnetic susceptibility, the magnetic flux density B and its gradient (dB/dz). As the reaction proceeds, a diffusion layer of the solute with changing susceptibility is formed at the interface because of the difference of the the magnetic susceptibility on the concentration of the solute. In the case of an unstable condition where the dimensionless number of magneto-convection S takes a positive value, the magnetic force is applied to the layer and induces numerous minute convection cells. The mass transfer of the solute is thus accelerated, so that it is predicted that the mass flux increases with the 1/3rd order of B(dB/dz) and the 4/3rd order of the concentration. The experiment was then performed by measuring the rate of the dissolution of copper sulfate pentahydrate crystal in water.

  9. Magnetic resonance for wireless power transfer

    OpenAIRE

    Hui, SYR

    2016-01-01

    Magnetic resonance has been a cornerstone of nonradiative wireless power transfer (WPT) since the late 19th century. However, some researchers have the misconception that magnetic resonance for WPT was developed recently. This article traces some early work of Tesla and other researchers related to the use of magnetic resonance in WPT. Included are some examples of magnetic resonance-based WPT projects conducted by researchers in the biomedical and power electronics communities over the last ...

  10. Magnetic nanofluid properties as the heat transfer enhancement agent

    Directory of Open Access Journals (Sweden)

    Roszko Aleksandra

    2016-01-01

    Full Text Available The main purpose of this paper was to investigate an influence of various parameters on the heat transfer processes with strong magnetic field utilization. Two positions of experimental enclosure in magnetic environment, two methods of preparation and three different concentrations of nanoparticles (0.0112, 0.056 and 0.112 vol.% were taken into account together with the magnetic field strength. Analysed nanofluids consisted of distilled water (diamagnetic and Cu/CuO particles (paramagnetic of 40–60 nm size. The nanofluids components had different magnetic properties what caused complex interaction of forces’ system. The heat transfer data and fluid flow structure demonstrated the influence of magnetic field on the convective phenomena. The most visible consequence of magnetic field application was the heat transfer enhancement and flow reorganization under applied conditions.

  11. Pleiotropic functions of magnetic nanoparticles for ex vivo gene transfer.

    Science.gov (United States)

    Kami, Daisuke; Kitani, Tomoya; Kishida, Tsunao; Mazda, Osam; Toyoda, Masashi; Tomitaka, Asahi; Ota, Satoshi; Ishii, Ryuga; Takemura, Yasushi; Watanabe, Masatoshi; Umezawa, Akihiro; Gojo, Satoshi

    2014-08-01

    Gene transfer technique has various applications, ranging from cellular biology to medical treatments for diseases. Although nonviral vectors, such as episomal vectors, have been developed, it is necessary to improve their gene transfer efficacy. Therefore, we attempted to develop a highly efficient gene delivery system combining an episomal vector with magnetic nanoparticles (MNPs). In comparison with the conventional method using transfection reagents, polyethylenimine-coated MNPs introduced episomal vectors more efficiently under a magnetic field and could express the gene in mammalian cells with higher efficiency and for longer periods. This novel in vitro separation method of gene-introduced cells utilizing the magnetic property of MNPs significantly facilitated the separation of cells of interest. Transplanted cells in vivo were detected using magnetic resonance. These results suggest that MNPs play multifunctional roles in ex vivo gene transfer, such as improvement of gene transfer efficacy, separation of cells, and detection of transplanted cells. This study convincingly demonstrates enhanced efficiency of gene transfer via magnetic nanoparticles. The method also enables magnetic sorting of cells positive for the transferred gene, and in vivo monitoring of the process with MRI. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Reduction of magnetic emission by increasing secondary side capacitor for ferrite geometry based series-series topology for wireless power transfer to vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik; Ahn, Seungyoung

    2014-01-01

    Magnetic fields emitted by wireless power transfer to vehicles can potentially affect living organisms. As a result, minimizing the magnetic emissions without compromising with the power transferred is one of the most significant challenges in the success of this technology. Active and passive...... and secondary currents from the standard design. Therefore, a part of the secondary magnetic flux comes in phase opposition with the primary flux and the resultant field is reduced. Operation point is shifted with the new design from the maximum power transfer resonance point and hence the reflected resistance...... is reduced. In order to maintain the same power level, the primary current and voltage have to increased and decreased in the same proportion. Also, the primary capacitor needs to be increased for maintaining unity input power factor in the system. The above statements are provided first with help...

  13. Technology transfer considerations for the collider dipole magnet

    International Nuclear Information System (INIS)

    Goodzeit, C.; Fischer, R.

    1991-03-01

    The R ampersand D program at the national laboratories has resulted in significant advances in design and fabrication methods for the Collider Dipole Magnets. The status of the transfer of the technology developed by the laboratories is reviewed. The continuation of the technology transfer program is discussed with a description of: (1) the relation of technology transfer activities to collider dipole product development; (2) content of the program relating to key magnet performance issues; and (3) methods to implement the program. 5 refs

  14. Energy transfers in dynamos with small magnetic Prandtl numbers

    KAUST Repository

    Kumar, Rohit

    2015-06-25

    We perform numerical simulation of dynamo with magnetic Prandtl number Pm = 0.2 on 10243 grid, and compute the energy fluxes and the shell-to-shell energy transfers. These computations indicate that the magnetic energy growth takes place mainly due to the energy transfers from large-scale velocity field to large-scale magnetic field and that the magnetic energy flux is forward. The steady-state magnetic energy is much smaller than the kinetic energy, rather than equipartition; this is because the magnetic Reynolds number is near the dynamo transition regime. We also contrast our results with those for dynamo with Pm = 20 and decaying dynamo. © 2015 Taylor & Francis.

  15. Heat transfer in a magnet C

    International Nuclear Information System (INIS)

    Sircilli Neto, F.; Passaro, A.; Borges, E.M.

    1991-01-01

    The cooling systems of nuclear reactors for spacial applications include direct current electromagnetic pumps, which are used to circulate the coolant fluid thru the reactor core. In this work, the transfer of the heat generated by the electrical current in a magnet C excitation coils, which is used in a prototype pump, was evaluated. Considering the processes of heat transfer by conduction, natural convection and radiation, the results of simulation with the codes HEATING5 and AUTHEATS indicate the utilization of the 180 sup(0)C thermal class conductor for a working Joule power of 4 10 sup(4) W/m sup(3) in each magnet coil. (author)

  16. Energy transfers and magnetic energy growth in small-scale dynamo

    KAUST Repository

    Kumar, Rohit Raj; Verma, Mahendra K.; Samtaney, Ravi

    2013-01-01

    In this letter we investigate the dynamics of magnetic energy growth in small-scale dynamo by studying energy transfers, mainly energy fluxes and shell-to-shell energy transfers. We perform dynamo simulations for the magnetic Prandtl number Pm = 20

  17. Modulation of spin transfer torque amplitude in double barrier magnetic tunnel junctions

    Science.gov (United States)

    Clément, P.-Y.; Baraduc, C.; Ducruet, C.; Vila, L.; Chshiev, M.; Diény, B.

    2015-09-01

    Magnetization switching induced by spin transfer torque is used to write magnetic memories (Magnetic Random Access Memory, MRAM) but can be detrimental to the reading process. It would be quite convenient therefore to modulate the efficiency of spin transfer torque. A solution is adding an extra degree of freedom by using double barrier magnetic tunnel junctions with two spin-polarizers, with controllable relative magnetic alignment. We demonstrate, for these structures, that the amplitude of in-plane spin transfer torque on the middle free layer can be efficiently tuned via the magnetic configuration of the electrodes. Using the proposed design could thus pave the way towards more reliable read/write schemes for MRAM. Moreover, our results suggest an intriguing effect associated with the out-of-plane (field-like) spin transfer torque, which has to be further investigated.

  18. Modulation of spin transfer torque amplitude in double barrier magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Clément, P.-Y.; Baraduc, C.; Chshiev, M.; Diény, B.; Ducruet, C.; Vila, L.

    2015-01-01

    Magnetization switching induced by spin transfer torque is used to write magnetic memories (Magnetic Random Access Memory, MRAM) but can be detrimental to the reading process. It would be quite convenient therefore to modulate the efficiency of spin transfer torque. A solution is adding an extra degree of freedom by using double barrier magnetic tunnel junctions with two spin-polarizers, with controllable relative magnetic alignment. We demonstrate, for these structures, that the amplitude of in-plane spin transfer torque on the middle free layer can be efficiently tuned via the magnetic configuration of the electrodes. Using the proposed design could thus pave the way towards more reliable read/write schemes for MRAM. Moreover, our results suggest an intriguing effect associated with the out-of-plane (field-like) spin transfer torque, which has to be further investigated

  19. Dynamics of magnetization in ferromagnet with spin-transfer torque

    Science.gov (United States)

    Li, Zai-Dong; He, Peng-Bin; Liu, Wu-Ming

    2014-11-01

    We review our recent works on dynamics of magnetization in ferromagnet with spin-transfer torque. Driven by constant spin-polarized current, the spin-transfer torque counteracts both the precession driven by the effective field and the Gilbert damping term different from the common understanding. When the spin current exceeds the critical value, the conjunctive action of Gilbert damping and spin-transfer torque leads naturally the novel screw-pitch effect characterized by the temporal oscillation of domain wall velocity and width. Driven by space- and time-dependent spin-polarized current and magnetic field, we expatiate the formation of domain wall velocity in ferromagnetic nanowire. We discuss the properties of dynamic magnetic soliton in uniaxial anisotropic ferromagnetic nanowire driven by spin-transfer torque, and analyze the modulation instability and dark soliton on the spin wave background, which shows the characteristic breather behavior of the soliton as it propagates along the ferromagnetic nanowire. With stronger breather character, we get the novel magnetic rogue wave and clarify its formation mechanism. The generation of magnetic rogue wave mainly arises from the accumulation of energy and magnons toward to its central part. We also observe that the spin-polarized current can control the exchange rate of magnons between the envelope soliton and the background, and the critical current condition is obtained analytically. At last, we have theoretically investigated the current-excited and frequency-adjusted ferromagnetic resonance in magnetic trilayers. A particular case of the perpendicular analyzer reveals that the ferromagnetic resonance curves, including the resonant location and the resonant linewidth, can be adjusted by changing the pinned magnetization direction and the direct current. Under the control of the current and external magnetic field, several magnetic states, such as quasi-parallel and quasi-antiparallel stable states, out

  20. Energy transfer from a superconducting magnet to an inductive load

    International Nuclear Information System (INIS)

    Onishi, Toshitada; Miura, Akinori.

    1977-01-01

    Experiments on energy transfer between two superconducting magnets have been carried out using an inductive energy transfer system similar to the flying capacitor system developed at the Karlsruhe Institute. In the present system the capacitor is grounded and diodes are used instead of thyristors, and a fraction of stored energy is transferred to the capacitor only when the relay connected in parallel to the magnet is switched off. The capacitor is expected to have no constraint in size, while in the flying capacitor system the capacitor is required to exceed a threshold size. Consequently it is possible to shorten the transfer time to some extent in comparison with the one in the flying capacitor system. Transfer experiments have been carried out using a storage magnet with inductance of 1.2H and a load of 0.41H. The capacitance is 200μF. It is possible to transfer 80.1% of the stored energy of 221 J into the load in less than about 0.35 seconds. (auth.)

  1. Heat transfer control in a plane magnetic fluid layer with a free surface

    International Nuclear Information System (INIS)

    Bashtovoi, V.G.; Pogirnitskaya, S.G.; Reks, A.G.

    1993-01-01

    The heat transfer mechanisms that are specific to a magnetic liquid have been already investigated extensively. The high sensitivity of the free magnetic liquid surface to the external magnetic field introduces a new feature into the heat transfer process. In the present work, the authors have investigated the possibility of controlling the heat transfer through the phenomenon of magnetic liquid surface instability in a uniform magnetic field. The conditions for heat transfer through a chamber, partially filled with a magnetic liquid, are governed by the characteristics of the free liquid surface and by its stability and development in the supercritical magnetic fields. The authors consider a model two-dimensional problem of heat transfer through a two-layer medium consisting of horizontally situated immiscible layers of magnetic and nonmagnetic liquids with given thermal conductivities. In the absence of an external magnetic field, the interface of the liquids represents a plane surface. In fields which exceed the critical magnitude, the interface is deformed along the wave. As the field intensity is increased, the amplitude of interface distortion becomes larger. The two-dimensional shape of the free magnetic liquid surface may be realized experimentally using two plane layers of magnetic and nonmagnetic liquids in a uniform magnetic field tangent to the interface of the component layers. 7 refs., 9 figs

  2. Testing of Prototype Magnetic Suspension Cryogenic Transfer Line

    Science.gov (United States)

    Fesmire, J. E.; Augustynowicz, S. D.; Nagy, Z. F.; Sojourner, S. J.; Shu, Q. S.; Cheng, G.; Susta, J. T.

    2006-04-01

    A 6-meter prototype cryogenic transfer line with magnetic suspension was tested for its mechanical and thermal performance at the Cryogenics Test Laboratory of NASA Kennedy Space Center (KSC). A test facility with two cryogenic end-boxes was designed and commissioned for the testing. Suspension mechanisms were verified through a series of tests with liquid nitrogen. The thermal performance of the prototype was determined using the new test apparatus. The tested prototype has incorporated temperature and vacuum pressure data acquisition ports, customized interfaces to cryogenic end-boxes, and instrumentation. All tests were conducted under simulated onsite transfer line working conditions. A static (boiloff rate measurement) testing method was employed to demonstrate the gross heat leak in the tested article. The real-time temperature distribution, vacuum level, levitation distance, and mass flow rate were measured. The main purpose of this paper is to summarize the testing facility design and preparation, test procedure, and primary test results. Special arrangements (such as turning on/off mechanical support units, observing levitation gap, and setting up the flowmeter) in testing of such a magnetically levitated transfer line are also discussed. Preliminary results show that the heat leak reduction of approximately one-third to one-half is achievable through such transfer lines with a magnetic suspension system.

  3. Active transfer of poloidal magnetic energy during plasma disruptions in J-TEXT

    International Nuclear Information System (INIS)

    Zhang, Ming; Zhang, Jun; Rao, Bo; Chen, Zhongyong; Li, Xiaolong; Xu, Wendi; Pan, Yuan; Yu, Kexun

    2016-01-01

    Highlights: • An alternative plasma disruption mitigation method by transferring partial poloidal magnetic energy out of the vacuum vessel has been presented in this paper. • This method can reduced the magnetic energy dissipated inside the vacuum vessel during disruption and mitigated the disruption damage. • This method has been experimentally verified in J-TEXT with an experiment system set up. • According to the experimental results, the magnetic energy dissipated inside the vacuum vessel during disruption can be reduced by 20% or more and the loop voltage can be reduced by 58%. - Abstract: The magnitude of the damaging effects of plasma disruptions on vacuum vessel (VV) components increases with the thermal energy and poloidal magnetic energy dissipated inside the VV. This study focuses on an alternative method, by which partial poloidal magnetic energy is transferred out of the VV. The quantity of the poloidal magnetic energy dissipated inside the VV (W_d_i_s) can be reduced with this method, and the damaging effects can be mitigated. Partial magnetic energy is transferred based on magnetic coupling by a group of energy transfer coils (ETCs) that are coupled with the plasma current. This method, which is called magnetic energy transfer (MET), has been experimentally verified in J-TEXT. W_d_i_s can be reduced by approximately 20%, and the loop voltage can be reduced by 58%. MET is established as a novel, promising, and effective plasma disruption mitigation method.

  4. Fundamental study on gene transfer utilizing magnetic force and jet injector

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, T.; Nakagami, H.; Akiyama, Y.; Nishjima, S. [Osaka University, Osaka (Japan)

    2017-03-15

    Recently, DNA vaccination is attracting attentions as a new therapeutic method for lifestyle diseases and autoimmune diseases. However, its clinical applications are limited because a safe and efficient gene transfer method has not been established yet. In this study, a new method of gene transfer was proposed which utilizes the jet injection and the magnetic transfection. The jet injection is a method to inject medical liquid by momentary high pressure without needle. The injected liquid diffuses in the bio tissue and the endocytosis is considered to be improved by the diffusion. The magnetic transfection is a method to deliver the conjugates of plasmid DNA and magnetic particles to the desired site by external magnetic field. It is expected that jet injection of the conjugates causes slight membrane disruptions and the traction of the conjugates by magnetic field induces the efficient gene transfer. In conclusion, the possibility of improvement of the gene expression by the combination of jet injection and magnetic transfection was confirmed.

  5. Fundamental study on gene transfer utilizing magnetic force and jet injector

    International Nuclear Information System (INIS)

    Hasegawa, T.; Nakagami, H.; Akiyama, Y.; Nishjima, S.

    2017-01-01

    Recently, DNA vaccination is attracting attentions as a new therapeutic method for lifestyle diseases and autoimmune diseases. However, its clinical applications are limited because a safe and efficient gene transfer method has not been established yet. In this study, a new method of gene transfer was proposed which utilizes the jet injection and the magnetic transfection. The jet injection is a method to inject medical liquid by momentary high pressure without needle. The injected liquid diffuses in the bio tissue and the endocytosis is considered to be improved by the diffusion. The magnetic transfection is a method to deliver the conjugates of plasmid DNA and magnetic particles to the desired site by external magnetic field. It is expected that jet injection of the conjugates causes slight membrane disruptions and the traction of the conjugates by magnetic field induces the efficient gene transfer. In conclusion, the possibility of improvement of the gene expression by the combination of jet injection and magnetic transfection was confirmed

  6. Analysis of the Ballot Shuffling Attack on Irish ballot counting for Proportional Representation by Single Transferable Vote (PR-STV)

    DEFF Research Database (Denmark)

    Cochran, Dermot Robert

    2015-01-01

    The current Irish legislation for counting of ballots does not fully comply with the true meaning of proportional representation by single transferable vote. This is due to the way in which second and subsequent transfers are handled, the legislative requirement to only count the last set of ball...

  7. Spin-transfer torque induced dynamics of magnetic vortices in nanopillars

    International Nuclear Information System (INIS)

    Sluka, Volker

    2011-01-01

    The subject of this work are lithographically defined cylindrical nanopillars containing a stack of two Iron disks separated by a nonmagnetic spacer. The dimensions of the ferromagnetic disks are chosen such that at low magnetic fields, the so-called magnetic vortex is stabilized. In zero field, the magnetization of these objects is basically parallel to the disk plane and circulates the disk center. In doing so, the build-up of large in-plane stray fields is avoided. At the center of this distribution however, exchange forces turn the magnetization out of the disk plane, resulting in the formation of what is referred to as the vortex core. Magnetic vortices have attracted much attention in recent years. This interest is in large parts due to the highly interesting dynamic properties of these structures. In this work the static and dynamic properties of magnetic vortices and their behavior under the influence of spin-transfer torque are investigated. This is achieved by measuring the static and time dependent magnetoresistance under the influence of external magnetic fields. The samples allow the formation of a large variety of states. First, the focus is set on configurations, where one disk is in a vortex state while the other one is homogeneously magnetized. It is shown that spin-transfer torque excites the vortex gyrotropic mode in this configuration. The dependence of the mode frequency on the magnetic field is analyzed. The measurements show that as the vortex center of gyration shifts through the disk under the action of the magnetic field, the effective potential in which it is moving undergoes a change in shape. This shape change is reflected in a V-shaped field dependence of the gyration frequency. Analytical calculations are performed to investigate the effect of the asymmetry of the spin-transfer torque efficiency function on the vortex dynamics. It is shown that by means of asymmetry, spin-transfer torque can transfer energy to a gyrating vortex even

  8. Magnetic metamaterial superlens for increased range wireless power transfer.

    Science.gov (United States)

    Lipworth, Guy; Ensworth, Joshua; Seetharam, Kushal; Huang, Da; Lee, Jae Seung; Schmalenberg, Paul; Nomura, Tsuyoshi; Reynolds, Matthew S; Smith, David R; Urzhumov, Yaroslav

    2014-01-10

    The ability to wirelessly power electrical devices is becoming of greater urgency as a component of energy conservation and sustainability efforts. Due to health and safety concerns, most wireless power transfer (WPT) schemes utilize very low frequency, quasi-static, magnetic fields; power transfer occurs via magneto-inductive (MI) coupling between conducting loops serving as transmitter and receiver. At the "long range" regime - referring to distances larger than the diameter of the largest loop - WPT efficiency in free space falls off as (1/d)(6); power loss quickly approaches 100% and limits practical implementations of WPT to relatively tight distances between power source and device. A "superlens", however, can concentrate the magnetic near fields of a source. Here, we demonstrate the impact of a magnetic metamaterial (MM) superlens on long-range near-field WPT, quantitatively confirming in simulation and measurement at 13-16 MHz the conditions under which the superlens can enhance power transfer efficiency compared to the lens-less free-space system.

  9. Magnetization transfer MR of cerebrovascular disorders using calculated images

    Energy Technology Data Exchange (ETDEWEB)

    Enomoto, Kyoko; Watabe, Tsuneya; Amanuma, Makoto; Heshiki, Atsuko [Saitama Medical School, Moroyama, Saitama (Japan)

    1997-06-01

    This study applied a magnetization transfer contrast method to patients with cerebrovascular disorders. A 1.5 T superconducting MR unit was used, and magnetization transfer ratio (MTR) images were calculated by evaluating two paired images before and after off-resonance gradient echo pulse sequences. The normal white matter showed the highest MTRs, CSF the lowest, and gray matter, intermediate. Cerebral ischemic patients showed two patterns according to the chronological stage of the affected area. Lesions in the acute and subacute stages revealed higher transfer rates than those in the chronic stage. Patients with cerebral hemorrhage were divided into three groups: the hyperacute group showed a low transfer pattern; the acute group presented inhomogeneous high transfer rates; and the subacute group showed remarkably low transfer rates. In the acute and subacute ischemic stages, increased macromolecules caused higher MTRs than in the chronic stage. In hemorrhagic groups, low MTRs in subacute hemorrhage reflected the transfer of methemoglobin. High MTRs in acute hemorrhage with rich deoxyhemoglobin suggested increased fibrin, plasma, and serum components of macromolecules. The MTC method provided new chronological information on cerebral hemorrhage, adding to that provided by routine MR images. (author)

  10. Energy transfers in dynamos with small magnetic Prandtl numbers

    KAUST Repository

    Kumar, Rohit; Verma, Mahendra K.; Samtaney, Ravi

    2015-01-01

    We perform numerical simulation of dynamo with magnetic Prandtl number Pm = 0.2 on 10243 grid, and compute the energy fluxes and the shell-to-shell energy transfers. These computations indicate that the magnetic energy growth takes place mainly due

  11. Spin–transfer torque oscillator in magnetic tunneling junction with short–wavelength magnon excitation

    Directory of Open Access Journals (Sweden)

    Shizhu Qiao

    2018-05-01

    Full Text Available Bloch–Bloembergen–Slonczewski (BBS equation is established by extending Bloch–Bloembergen equation, and it is used to study magnetization oscillation in the free magnetic layer of a magnetic tunneling junction. Since both short–wavelength magnon excitation and spin–transfer torque are taken into account in the BBS equation, it is distinguished from Landau–Lifshitz–Gilbert–Slonczewski equation. The macro–spin BBS model predicts that the transverse relaxation time in free magnetic layer should be long enough, as compared with the longitudinal relaxation time, to achieve stable magnetization oscillation for spin–transfer torque oscillator application. Moreover, field–like torque favors the tolerance of fast transverse relaxation, which makes magnetic tunneling junction a better choice than spin valve for the spin–transfer torque oscillator application.

  12. A chopper circuit for energy transfer between superconducting magnets

    International Nuclear Information System (INIS)

    Onishi, Toshitada; Tateishi, Hiroshi; Takeda, Masatoshi; Matsuura, Toshiaki; Nakatani, Toshio.

    1986-01-01

    It has been suggested that superconducting magnets could provide a medium for storing energy and supplying the large energy pulses needed by experimental nuclear-fusion equipment and similar loads. Based on this concept, tests on energy transfer between superconducting magnets are currently being conducted at the Agency of Industrial Science and Technology's Electrotechnical Laboratory. Mitsubishi Electric has pioneered the world's first chopper circuit for this application. The circuit has the advantages of being simple and permitting high-speed, bipolar energy transfer. The article describes this circuit and its testing. (author)

  13. Cellular transfer of magnetic nanoparticles via cell microvesicles: impact on cell tracking by magnetic resonance imaging.

    Science.gov (United States)

    Silva, Amanda K Andriola; Wilhelm, Claire; Kolosnjaj-Tabi, Jelena; Luciani, Nathalie; Gazeau, Florence

    2012-05-01

    Cell labeling with magnetic nanoparticles can be used to monitor the fate of transplanted cells in vivo by magnetic resonance imaging. However, nanoparticles initially internalized in administered cells might end up in other cells of the host organism. We investigated a mechanism of intercellular cross-transfer of magnetic nanoparticles to different types of recipient cells via cell microvesicles released under cellular stress. Three cell types (mesenchymal stem cells, endothelial cells and macrophages) were labeled with 8-nm iron oxide nanoparticles. Then cells underwent starvation stress, during which they produced microvesicles that were subsequently transferred to unlabeled recipient cells. The analysis of the magnetophoretic mobility of donor cells indicated that magnetic load was partially lost under cell stress. Microvesicles shed by stressed cells participated in the release of magnetic label. Moreover, such microvesicles were uptaken by naïve cells, resulting in cellular redistribution of nanoparticles. Iron load of recipient cells allowed their detection by MRI. Cell microvesicles released under stress may be disseminated throughout the organism, where they can be uptaken by host cells. The transferred cargo may be sufficient to allow MRI detection of these secondarily labeled cells, leading to misinterpretations of the effectiveness of transplanted cells.

  14. Proportional-Type Performance Recovery DC-Link Voltage Tracking Algorithm for Permanent Magnet Synchronous Generators

    Directory of Open Access Journals (Sweden)

    Seok-Kyoon Kim

    2017-09-01

    Full Text Available This study proposes a disturbance observer-based proportional-type DC-link voltage tracking algorithm for permanent magnet synchronous generators (PMSGs. The proposed technique feedbacks the only proportional term of the tracking errors, and it contains the nominal static and dynamic feed-forward compensators coming from the first-order disturbance observers. It is rigorously proved that the proposed method ensures the performance recovery and offset-free properties without the use of the integrators of the tracking errors. A wind power generation system has been simulated to verify the efficacy of the proposed method using the PSIM (PowerSIM software with the DLL (Dynamic Link Library block.

  15. Quantitative Magnetization Transfer Imaging in Human Brain at 3 T via Selective Inversion Recovery

    OpenAIRE

    Dortch, Richard D.; Li, Ke; Gochberg, Daniel F.; Welch, E. Brian; Dula, Adrienne N.; Tamhane, Ashish A.; Gore, John C.; Smith, Seth A.

    2011-01-01

    Quantitative magnetization transfer imaging yields indices describing the interactions between free water protons and immobile, macromolecular protons—including the macromolecular to free pool size ratio (PSR) and the rate of magnetization transfer between pools kmf. This study describes the first implementation of the selective inversion recovery quantitative magnetization transfer method on a clinical 3.0-T scanner in human brain in vivo. Selective inversion recovery data were acquired at 1...

  16. Bi-directional magnetic resonance based wireless power transfer for electronic devices

    International Nuclear Information System (INIS)

    Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan; Mishra, Debasish

    2015-01-01

    In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency

  17. Bi-directional magnetic resonance based wireless power transfer for electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan; Mishra, Debasish [Department of Electronics and Instrumentation Engineering, Institute of Technical Education and Research, Siksha ‘O’ Anushandhan University, Bhubaneswar 751030 (India)

    2015-09-28

    In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency.

  18. Polarization transfer in relativistic magnetized plasmas

    Science.gov (United States)

    Heyvaerts, Jean; Pichon, Christophe; Prunet, Simon; Thiébaut, Jérôme

    2013-04-01

    The polarization transfer coefficients of a relativistic magnetized plasma are derived. These results apply to any momentum distribution function of the particles, isotropic or anisotropic. Particles interact with the radiation either in a non-resonant mode when the frequency of the radiation exceeds their characteristic synchrotron emission frequency or quasi-resonantly otherwise. These two classes of particles contribute differently to the polarization transfer coefficients. For a given frequency, this dichotomy corresponds to a regime change in the dependence of the transfer coefficients on the parameters of the particle's population, since these parameters control the relative weight of the contribution of each class of particles. Our results apply to either regimes as well as the intermediate one. The derivation of the transfer coefficients involves an exact expression of the conductivity tensor of the relativistic magnetized plasma that has not been used hitherto in this context. Suitable expansions valid at frequencies much larger than the cyclotron frequency allow us to analytically perform the summation over all resonances at high harmonics of the relativistic gyrofrequency. The transfer coefficients are represented in the form of two-variable integrals that can be conveniently computed for any set of parameters by using Olver's expansion of high-order Bessel functions. We particularize our results to a number of distribution functions, isotropic, thermal or power law, with different multipolar anisotropies of low order, or strongly beamed. Specifically, earlier exact results for thermal distributions are recovered. For isotropic distributions, the Faraday coefficients are expressed in the form of a one-variable quadrature over energy, for which we provide the kernels in the high-frequency limit and in the asymptotic low-frequency limit. An interpolation formula extending over the full energy range is proposed for these kernels. A similar reduction to a

  19. On the inverse transfer of (non-)helical magnetic energy in a decaying magnetohydrodynamic turbulence

    Science.gov (United States)

    Park, Kiwan

    2017-12-01

    In our conventional understanding, large-scale magnetic fields are thought to originate from an inverse cascade in the presence of magnetic helicity, differential rotation or a magneto-rotational instability. However, as recent simulations have given strong indications that an inverse cascade (transfer) may occur even in the absence of magnetic helicity, the physical origin of this inverse cascade is still not fully understood. We here present two simulations of freely decaying helical and non-helical magnetohydrodynamic (MHD) turbulence. We verified the inverse transfer of helical and non-helical magnetic fields in both cases, but we found the underlying physical principles to be fundamentally different. In the former case, the helical magnetic component leads to an inverse cascade of magnetic energy. We derived a semi-analytic formula for the evolution of large-scale magnetic field using α coefficient and compared it with the simulation data. But in the latter case, the α effect, including other conventional dynamo theories, is not suitable to describe the inverse transfer of non-helical magnetic energy. To obtain a better understanding of the physics at work here, we introduced a 'field structure model' based on the magnetic induction equation in the presence of inhomogeneities. This model illustrates how the curl of the electromotive force leads to the build up of a large-scale magnetic field without the requirement of magnetic helicity. And we applied a quasi-normal approximation to the inverse transfer of magnetic energy.

  20. Pressure drop and heat transfer of lithium single-phase flow under transverse magnetic field

    International Nuclear Information System (INIS)

    Takahashi, Minoru; Aritomi, Masanori; Inoue, Akira; Matsuzaki, Mitsuo

    1996-01-01

    Pressure drop and heat transfer characteristics of a lithium single-phase flow in a rectangular channel was investigated experimentally in the presence of a magnetic field. Friction loss coefficient under non-magnetic field and skin friction coefficient under magnetic field agreed well with the Blasius formula and a simple analytical expression, respectively. Nusselt number under non-magnetic field was slightly lower than the correlation by Hartnett and Irvine. Heat transfer was enhanced by increasing magnetic field above the Hartmann number of about 200. (author)

  1. Magnetic MIMO Signal Processing and Optimization for Wireless Power Transfer

    Science.gov (United States)

    Yang, Gang; Moghadam, Mohammad R. Vedady; Zhang, Rui

    2017-06-01

    In magnetic resonant coupling (MRC) enabled multiple-input multiple-output (MIMO) wireless power transfer (WPT) systems, multiple transmitters (TXs) each with one single coil are used to enhance the efficiency of simultaneous power transfer to multiple single-coil receivers (RXs) by constructively combining their induced magnetic fields at the RXs, a technique termed "magnetic beamforming". In this paper, we study the optimal magnetic beamforming design in a multi-user MIMO MRC-WPT system. We introduce the multi-user power region that constitutes all the achievable power tuples for all RXs, subject to the given total power constraint over all TXs as well as their individual peak voltage and current constraints. We characterize each boundary point of the power region by maximizing the sum-power deliverable to all RXs subject to their minimum harvested power constraints. For the special case without the TX peak voltage and current constraints, we derive the optimal TX current allocation for the single-RX setup in closed-form as well as that for the multi-RX setup. In general, the problem is a non-convex quadratically constrained quadratic programming (QCQP), which is difficult to solve. For the case of one single RX, we show that the semidefinite relaxation (SDR) of the problem is tight. For the general case with multiple RXs, based on SDR we obtain two approximate solutions by applying time-sharing and randomization, respectively. Moreover, for practical implementation of magnetic beamforming, we propose a novel signal processing method to estimate the magnetic MIMO channel due to the mutual inductances between TXs and RXs. Numerical results show that our proposed magnetic channel estimation and adaptive beamforming schemes are practically effective, and can significantly improve the power transfer efficiency and multi-user performance trade-off in MIMO MRC-WPT systems.

  2. Theory of radiative transfer in a strong magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, S [Ibaraki Univ., Mito (Japan). Dept. of Physics

    1975-07-01

    A theory is presented of the radiative transfer in a magnetized plasma with the opacity determined by the Thomson scattering. The Thomson cross section in the magnetic field is highly anisotropic and polarization-dependent. In order to cope with this situation, it is found useful to deal directly with the scattering amplitude (2x2 matrix in the polarization vector space) rather than the intensity. In this way it is possible to take into account the coherent superposition of the forward multiple-scattering amplitudes as a photon propagates. The equation of transfer is established accordingly and approximate solutions are found in the limits of small and large optical thickness. The latter solution is used to find the intensity and the polarization of thermal X-rays from a magnetic dipole star. The concept of mean free path is discussed and also it is shown that the Faraday rotation naturally comes about as a result of the multiple forward scattering.

  3. Accurate computation of transfer maps from magnetic field data

    International Nuclear Information System (INIS)

    Venturini, Marco; Dragt, Alex J.

    1999-01-01

    Consider an arbitrary beamline magnet. Suppose one component (for example, the radial component) of the magnetic field is known on the surface of some imaginary cylinder coaxial to and contained within the magnet aperture. This information can be obtained either by direct measurement or by computation with the aid of some 3D electromagnetic code. Alternatively, suppose that the field harmonics have been measured by using a spinning coil. We describe how this information can be used to compute the exact transfer map for the beamline element. This transfer map takes into account all effects of real beamline elements including fringe-field, pseudo-multipole, and real multipole error effects. The method we describe automatically takes into account the smoothing properties of the Laplace-Green function. Consequently, it is robust against both measurement and electromagnetic code errors. As an illustration we apply the method to the field analysis of high-gradient interaction region quadrupoles in the Large Hadron Collider (LHC)

  4. Study of magnetic field to promote oxygen transfer and its application in zinc–air fuel cells

    International Nuclear Information System (INIS)

    Shi, Jicheng; Xu, Hongfeng; Lu, Lu; Sun, Xin

    2013-01-01

    Highlights: ► High magnetic strength reduces R ct and increases C d in oxygen reduction reaction. ► Oxygen diffusion and transfer coefficient become large in high magnetic strength. ► The magnetic ZAFC discharge performance is better than the nonmagnetic ZAFC. ► Increased NdFeB/C load density improves the magnetic ZAFC discharge performance. ► Excess NdFeB/C load density decreases the magnetic ZAFC discharge performance. -- Abstract: This study investigates the effects of magnetic field on oxygen transfer and the correlations of electrochemical parameters in different magnetic strengths. The discharge performance of zinc–air fuel cell (ZAFC) was tested under magnetic and nonmagnetic conditions using neodymium–iron–boron/carbon (NdFeB/C) magnetic particles in ZAFC cathode. The results showed that the oxygen diffusion coefficient (D Oi ) and transfer coefficient (α i ) increased by 102.14% and 52.38% when the magnetic strength increased from 0 mT to 5.0 mT, respectively. In addition, the electric double-layer capacitance (C d ) increased from 8.16 to 22.46 μF cm −2 , the charge-transfer resistance (R ct ) decreased from 9.43 Ω cm 2 to 6.02 Ω cm 2 , and the oxygen reduction reaction (ORR) current was improved. With the NdFeB/C load density of 2.4 mg cm −2 in ZAFC cathode, the discharge current of magnetic ZAFC increased by 13.86% compared with the nonmagnetic ZAFC at the 0.80 V discharge voltage. These results indicate that magnetic strength has a positive correlation with D Oi , α i , and the ORR current. Under magnetic attractions, the oxygen transfer process is easier at the Pt/C catalytic surface, and the discharge performance of magnetic ZAFC is superior to the nonmagnetic ZAFC. At lower NdFeB/C load density, increasing the NdFeB/C load density facilitates oxygen transfer and improves the discharge performance of ZAFC. However, the magnetic ZAFC discharge performance decreases at a higher NdFeB/C load density because of the blocked oxygen

  5. Realistic ion optical transfer maps for Super-FRS magnets from numerical field data

    Energy Technology Data Exchange (ETDEWEB)

    Kazantseva, Erika; Boine-Frankenheim, Oliver [Technische Universitaet Darmstadt (Germany)

    2016-07-01

    In large aperture accelerators such as Super-FRS, the non-linearity of the magnetic field in bending elements leads to the non-linear beam dynamics, which cannot be described by means of linear ion optics. Existing non-linear approach is based on the Fourier harmonics formalism and is not working if horizontal aperture is bigger as vertical or vice versa. In Super-FRS dipole the horizontal aperture is much bigger than the vertical. Hence, it is necessary to find a way to create the higher order transfer map for this dipole to accurately predict the particle dynamics in the realistic magnetic fields in the whole aperture. The aim of this work is to generate an accurate high order transfer map of magnetic elements from measured or simulated 3D magnetic field data. Using differential algebraic formalism allows generating transfer maps automatically via numerical integration of ODEs of motion in beam physics coordinates along the reference path. To make the transfer map accurate for all particles in the beam, the magnetic field along the integration path should be represented by analytical function, matching with the real field distribution in the volume of interest. Within this work the steps of high order realistic transfer map production starting from the field values on closed box, covering the volume of interest, will be analyzed in detail.

  6. Interferometric study on the mass transfer in cryogenic distillation under magnetic field

    Science.gov (United States)

    Bao, S. R.; Zhang, R. P.; Y Rong, Y.; Zhi, X. Q.; Qiu, L. M.

    2017-12-01

    Cryogenic distillation has long been used for the mass production of industrial gases because of its features of high efficiency, high purity, and capability to produce noble gases. It is of great theoretical and practical significance to explore methods to improve the mass transfer efficiency in cryogenic distillation. The negative correlation between the susceptibility of paramagnetic oxygen and temperature provides a new possibility of comprehensive utilization of boiling point and susceptibility differences in cryogenic distillation. Starting from this concept, we proposed a novel distillation intensifying method by using gradient magnetic field, in which the magnetic forces enhance the transport of the oxygen molecules to the liquid phase in the distillation. In this study, a cryogenic testbed was designed and fabricated to study the diffusion between oxygen and nitrogen under magnetic field. A Mach-Zehnder interferometer was used to visualize the concentration distribution during the diffusion process. The mass transfer characteristics with and without magnetic field, in the chamber filled with the magnetized medium, were systematically studied. The concentration redistribution of oxygen was observed, and the stable stratified diffusion between liquid oxygen and nitrogen was prolonged by the non-uniform magnetic field. The experimental results show that the magnetic field can efficiently influence the mass transfer in cryogenic distillation, which can provide a new mechanism for the optimization of air separation process.

  7. Effect of an alternating nonuniform magnetic field on ferrofluid flow and heat transfer in a channel

    International Nuclear Information System (INIS)

    Goharkhah, Mohammad; Ashjaee, Mehdi

    2014-01-01

    Forced convective heat transfer of water based Fe 3 O 4 nanofluid (ferrofluid) in the presence of an alternating non-uniform magnetic field is investigated numerically. The geometry is a two-dimensional channel which is subjected to a uniform heat flux at the top and bottom surfaces. Nonuniform magnetic field produced by eight line source dipoles is imposed on several parts of the channel. Also, a rectangular wave function is applied to the dipoles in order to turn them on and off alternatingly. The effects of the alternating magnetic field strength and frequency on the convective heat transfer are investigated for four different Reynolds numbers (Re=100, 600, 1200 and 2000) in the laminar flow regime. Comparing the results with zero magnetic field case, show that the heat transfer enhancement increases with the Reynolds number and reaches a maximum of 13.9% at Re=2000 and f=20 Hz. Moreover, at a constant Reynolds number, it increases with the magnetic field intensity while an optimum value exists for the frequency. Also, the optimum frequency increases with the Reynolds number. On the other hand, the heat transfer enhancement due to the magnetic field is always accompanied by a pressure drop penalty. A maximum pressure drop increase of 6% is observed at Re=2000 and f=5 Hz which shows that the pressure drop increase is not as significant as the heat transfer enhancement. - Highlights: • An alternating magnetic field is imposed on ferrofluid flow in a heated channel. • Heat transfer is enhanced noticeably compared to the case with no magnetic field. • Heat transfer depends on Reynolds number, magnetic field intensity and frequency. • Optimum frequency is independent of intensity but increases with Reynolds number. • Pressure drop increase is not as significant as the heat transfer enhancement

  8. Magnetic nanoparticles stimulation to enhance liquid-liquid two-phase mass transfer under static and rotating magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Azimi, Neda; Rahimi, Masoud, E-mail: masoudrahimi@yahoo.com

    2017-01-15

    Rotating magnetic field (RMF) was applied on a micromixer to break the laminar flow and induce chaotic flow to enhance mass transfer between two-immiscible organic and aqueous phases. The results of RMF were compared to those of static magnetic field (SMF). For this purpose, experiments were carried out in a T-micromixer at equal volumetric flow rates of organic and aqueous phases. Fe{sub 3}O{sub 4} nanoparticles were synthesized by co-precipitation technique and they were dissolved in organic phase. Results obtained from RMF and SMF were compared in terms of overall volumetric mass transfer coefficient (K{sub L}a) and extraction efficiency (E) at various Reynolds numbers. Generally, RMF showed higher effect in mass transfer characteristics enhancement compared with SMF. The influence of rotational speeds of magnets (ω) in RMF was investigated, and measurable enhancements of K{sub L}a and E were observed. In RMF, the effect of magnetic field induction (B) was investigated. The results reveal that at constant concentration of nanoparticles, by increasing of B, mass transfer characteristics will be enhanced. The effect of various nanoparticles concentrations (ϕ) within 0.002–0.01 (w/v) on K{sub L}a and E at maximum induction of RMF (B=76 mT) was evaluated. Maximum values of K{sub L}a (2.1±0.001) and E (0.884±0.001) were achieved for the layout of RMF (B=76 mT), ω=16 rad/s and MNPs concentration of 0.008–0.01 (w/v). - Highlights: • Magnetic nanoparticles used for mixing of two immiscible liquids in a micromixer. • Extraction efficiency of rotating magnetic field (RMF) is compared with static one. • In RMF, the effect of the angular speed on KLa and E enhancement is reported. • In RMF, at a selected magnet distance effect of nanoparticle concentration is reported.

  9. New magnet transport system for the LHC beam transfer lines

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system (pictured here in one of the tunnels) is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. The lead vehicle is powered by an electric rail set into the roof of the tunnel. The system is backed up by electrical batteries that enable it to operate in the absence of an outside power source or in the event of power failure. Last but not least, for the long-distance transport of magnets, it can be optically guided by a line traced on the tunnel floor. The convoy moves through the particularly narr...

  10. The effect of a magnetic field on heat transfer in a slotted channel

    International Nuclear Information System (INIS)

    Evtushenko, I.A.; Hua, T.Q.; Kirillov, I.R.; Reed, Claude B.; Sidorenkov, S.S.

    1995-01-01

    The results of numerical and experimental studies of liquid metal heat transfer in slotted channels in a transverse magnetic field are presented. Test results showed an improvement in heat transfer in a straight channel at low and moderate interaction parameter N. The Nusselt number at small N (around 120) was up to twofold higher than in turbulent flow without a magnetic field, the Peclet number being equal. This effect of heat transfer enhancement is caused by the generation and development of large-scale velocity fluctuations close to the heated wall area. Qualitative and quantitative correlations between heat transfer and velocity fluctuation characteristics are presented. (orig.)

  11. The Quadrupole Magnets for the LHC Injection Transfer Lines

    CERN Document Server

    Chertok, I; Churkin, I N; Giesch, Manfred; Golubenko, O B; Kalbreier, Willi; Kouba, G; Mejidzade, V; Mikhailov, S; Steshov, A; Sukhanov, A; Sukhina, B; Schirm, K M; Weisse, E

    2000-01-01

    Two injection transfer lines, each about 2.8 km long, are being built to transfer protons at 450 GeV from the Super Proton Synchrotron (SPS) to the Large Hadron Collider (LHC). A total of 180 quadrupole magnets are required; they are produced in the framework of the contribution of the Russian Federation to the construction of the LHC. The classical quadrupoles, built from laminated steel cores and copper coils, have a core length of 1.4 m, an inscribed diameter of 32 mm and a strength of 53.5 T/m at a current of 530 A. The total weight of one magnet is 1.1 ton. For obtaining the required field quality at the small inscribed diameter, great care in the stamping of the laminations and the assembly of quadrants is necessary. Special instruments have been developed to measure, with a precision of some mm, the variations of the pole gaps over the full length of the magnet and correlate them to the obtained field distribution. The design has been developed in a collaboration between BINP and CERN. Fabrication and ...

  12. Experimental study on heat transfer augmentation of graphene based ferrofluids in presence of magnetic field

    DEFF Research Database (Denmark)

    Sadeghinezhad, Emad; Mehrali, Mohammad; Akhiani, Amir Reza

    2017-01-01

    The effect of a permanent magnetic field on the heat transfer characteristics of hybrid graphene-magnetite nanofluids (hybrid nanofluid) under forced laminar flow was experimentally investigated. For this purpose, a reduced graphene oxide-Fe3O4 was synthesized by using two-dimensional (2D) graphene...... and it shows that the thermal conductivity increased up to 11%. The hybrid nanofluid behaves as a Newtonian fluid with liquid like behavior with superparamagnetic properties as was evident from its magnetic saturation value at 45.9 emu/g. Moreover, the experimental heat-transfer results indicated that the heat...... transfer enhancement of the hybrid nanofluid compared to the control fluid (distilled water) was negligible when no magnetic field was applied. Additionally, the convective heat transfer was significantly improved under the influence of a magnetic field with a maximum enhancement of 82% in terms...

  13. Neutron scattering investigation of magnetic excitations at high energy transfers

    International Nuclear Information System (INIS)

    Loong, C.K.

    1984-01-01

    With the advance of pulsed spallation neutron sources, neutron scattering investigation of elementary excitations in magnetic materials can now be extended to energies up to several hundreds of MeV. We have measured, using chopper spectrometers and time-of-flight techniques, the magnetic response functions of a series of d and f transition metals and compounds over a wide range of energy and momentum transfer. In PrO 2 , UO 2 , BaPrO 3 and CeB 6 we observed crystal-field transitions between the magnetic ground state and the excited levels in the energy range from 40 to 260 MeV. In materials exhibiting spin-fluctuation or mixed-valent character such as Ce 74 Th 26 , on the other hand, no sharp crystal-field lines but a broadened quasielastic magnetic peak was observed. The line width of the quasielastic component is thought to be connected to the spin-fluctuation energy of the 4f electrons. The significance of the neutron scattering results in relation to the ground state level structure of the magnetic ions and the spin-dynamics of the f electrons is discussed. Recently, in a study of the spin-wave excitations in itinerant magnetic systems, we have extended the spin-wave measurements in ferromagnetic iron up to about 160 MeV. Neutron scattering data at high energy transfers are of particular interest because they provide direct comparison with recent theories of itinerant magnetism. 26 references, 7 figures

  14. Accurate magnetic field calculations for contactless energy transfer coils

    OpenAIRE

    Sonntag, C.L.W.; Spree, M.; Lomonova, E.A.; Duarte, J.L.; Vandenput, A.J.A.

    2007-01-01

    In this paper, a method for estimating the magnetic field intensity from hexagon spiral windings commonly found in contactless energy transfer applications is presented. The hexagonal structures are modeled in a magneto-static environment using Biot-Savart current stick vectors. The accuracy of the models are evaluated by mapping the current sticks and the hexagon spiral winding tracks to a local twodimensional plane, and comparing their two-dimensional magnetic field intensities. The accurac...

  15. Analytical study of synchronization in spin-transfer-driven magnetization dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bonin, Roberto [Politecnico di Torino - sede di Verres, via Luigi Barone 8, I-11029 Verres (Italy); Bertotti, Giorgio; Bortolotti, Paolo [Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, I-10135 Torino (Italy); Serpico, Claudio [Dipartimento di Ingegneria Elettrica, Universita di Napoli ' Federico II' , via Claudio 21, I-80125 Napoli (Italy); D' Aquino, Massimiliano [Dipartimento per le Tecnologie, Universita di Napoli ' Parthenope' , via Medina 40, I-80133 Napoli (Italy); Mayergoyz, Isaak D, E-mail: p.bortolotti@inrim.i [Electrical and Computer Engineering Department and UMIACS, University of Maryland, College Park MD 20742 (United States)

    2010-01-01

    An analytical study of the synchronization effects in spin-transfer-driven nanomagnets subjected to either microwave magnetic fields or microwave electrical currents is discussed. Appropriate stability diagrams are constructed and the conditions under which the current-induced magnetization precession is synchronized by the microwave external excitation are derived and discussed. Analytical predictions are given for the existence of phase-locking effects in current-induced magnetization precessions and for the occurrence of hysteresis in phase-locking as a function of the spin-polarized current.

  16. Magnetically Suspended Linear Pulse Motor for Semiconductor Wafer Transfer in Vacuum Chamber

    Science.gov (United States)

    Moriyama, Shin-Ichi; Hiraki, Naoji; Watanabe, Katsuhide; Kanemitsu, Yoichi

    1996-01-01

    This paper describes a magnetically suspended linear pulse motor for a semiconductor wafer transfer robot in a vacuum chamber. The motor can drive a wafer transfer arm horizontally without mechanical contact. In the construction of the magnetic suspension system, four pairs of linear magnetic bearings for the lift control are used for the guidance control as well. This approach allows us to make the whole motor compact in size and light in weight. The tested motor consists of a double-sided stator and a transfer arm with a width of 50 mm and a total length of 700 mm. The arm, like a ladder in shape, is designed as the floating element with a tooth width of 4 mm (a tooth pitch of 8 mm). The mover mass is limited to about 1.6 kg by adopting such an arm structure, and the ratio of thrust to mover mass reaches to 3.2 N/kg under a broad air gap (1 mm) between the stator teeth and the mover teeth. The performance testing was carried out with a transfer distance less than 450 mm and a transfer speed less than 560 mm/s. The attitude of the arm was well controlled by the linear magnetic bearings with a combined use, and consequently the repeatability on the positioning of the arm reached to about 2 micron. In addition, the positioning accuracy was improved up to about 30 micron through a compensation of the 128-step wave current which was used for the micro-step drive with a step increment of 62.5 micron.

  17. Wireless Energy Transfer Through Magnetic Reluctance Coupling

    International Nuclear Information System (INIS)

    Pillatsch, P

    2014-01-01

    Energy harvesting from human motion for body worn or implanted devices faces the problem of the wearer being still, e.g. while asleep. Especially for medical devices this can become an issue if a patient is bed-bound for prolonged periods of time and the internal battery of a harvesting system is not recharged. This article introduces a mechanism for wireless energy transfer based on a previously presented energy harvesting device. The internal rotor of the energy harvester is made of mild steel and can be actuated through a magnetic reluctance coupling to an external motor. The internal piezoelectric transducer is consequently actuated and generates electricity. This paper successfully demonstrates energy transfer over a distance of 16 mm in air and an achieved power output of 85 μW at 25 Hz. The device functional volume is 1.85 cm 3 . Furthermore, it was demonstrated that increasing the driving frequency beyond 25 Hz did not yield a further increase in power output. Future research will focus on improving the reluctance coupling, e.g. by investigating the use of multiple or stronger magnets, in order to increase transmission distance

  18. Magnetization Transfer Effects on the Efficiency of Flow-driven Adiabatic Fast Passage Inversion of Arterial Blood

    OpenAIRE

    Hernandez-Garcia, Luis; Lewis, David P.; Moffat, Bradford; Branch, Craig A.

    2007-01-01

    Continuous arterial spin labeling experiments typically use flow-driven adiabatic fast passage (AFP) inversion of the arterial blood water protons. In this article, we measure the effect of magnetization transfer in blood and how it affects the inversion label. We use modified Bloch equations to model flow-driven adiabatic inversion in the presence of magnetization transfer in blood flowing at velocities from 1 to 30 cm/s in order to explain our findings. Magnetization transfer results in a r...

  19. Pulsed magnetization transfer imaging with body coil transmission at 3 Tesla: feasibility and application.

    Science.gov (United States)

    Smith, Seth A; Farrell, Jonathan A D; Jones, Craig K; Reich, Daniel S; Calabresi, Peter A; van Zijl, Peter C M

    2006-10-01

    Pulsed magnetization transfer (MT) imaging has been applied to quantitatively assess brain pathology in several diseases, especially multiple sclerosis (MS). To date, however, because of the high power deposition associated with the use of short, rapidly repeating MT prepulses, clinical application has been limited to lower field strengths. The contrast-to-noise ratio (CNR) of MT is limited, and this method would greatly benefit from the use of higher magnetic fields and phased-array coil reception. However, power deposition is proportional to the square of the magnetic field and scales with coil size, and MT experiments are already close to the SAR limit at 1.5T even when smaller transmit coils are used instead of the body coil. Here we show that these seemingly great obstacles can be ameliorated by the increased T(1) of tissue water at higher field, which allows for longer maintenance of sufficiently high saturation levels while using a reduced duty cycle. This enables a fast (5-6 min) high-resolution (1.5 mm isotropic) whole-brain MT acquisition with excellent anatomical visualization of gray matter (GM) and white matter (WM) structures, and even substructures. The method is demonstrated in nine normal volunteers and five patients with relapsing remitting MS (RRMS), and the results show a clear delineation of heterogeneous lesions.

  20. Magnetic torque transferring study for bulk High-Tc superconductors and permanent magnets

    International Nuclear Information System (INIS)

    Wongsatanawarid, A; Suzuki, A; Seki, H; Murakami, M

    2009-01-01

    The torque transferring mechanism taking place in a superconducting mixer design has been studied. Several coupling magnetic arrangements were investigated for more details in the engineering design. A bulk superconductor sample was used to study the torque forces for various cooling gaps, and the twist angle dependence was also monitored for the rotational stiffness in stability. The experimental data with four permanent magnet configurations have been studied in the present work. The maximum torque forces are summarized for usage of engineering design with various gaps. The torque/gap characteristics for four configurations were also measured for the optimisation of the torque at a designed operating gap.

  1. Magnetic resonance imaging findings after rectus femoris transfer surgery

    International Nuclear Information System (INIS)

    Gold, Garry E.; Asakawa, Deanna S.; Blemker, Silvia S.; Delp, Scott L.

    2004-01-01

    We describe the magnetic resonance (MR) imaging appearance of the knee flexor and extensor tendons after bilateral rectus femoris transfer and hamstring lengthening surgery in five patients (10 limbs) with cerebral palsy. Three-dimensional models of the path of the transferred tendon were constructed in all cases. MR images of the transferred and lengthened tendons were examined and compared with images from ten non-surgical subjects. The models showed that the path of the transferred rectus femoris tendon had a marked angular deviation near the transfer site in all cases. MR imaging demonstrated irregular areas of low signal intensity near the transferred rectus femoris and around the hamstrings in all subjects. Eight of the ten post-surgical limbs showed evidence of fluid near or around the transferred or lengthened tendons. This was not observed in the non-surgical subjects. Thus, MR imaging of patients with cerebral palsy after rectus femoris transfer and hamstring-lengthening surgery shows evidence of signal intensity and contour changes, even several years after surgery. (orig.)

  2. Review of heat transfer problems associated with magnetically-confined fusion reactor concepts

    International Nuclear Information System (INIS)

    Hoffman, M.A.; Werner, R.W.; Carlson, G.A.; Cornish, D.N.

    1976-01-01

    Conceptual design studies of possible fusion reactor configurations have revealed a host of interesting and sometimes extremely difficult heat transfer problems. The general requirements imposed on the coolant system for heat removal of the thermonuclear power from the reactor are discussed. In particular, the constraints imposed by the fusion plasma, neutronics, structure and magnetic field environment are described with emphasis on those aspects which are unusual or unique to fusion reactors. Then the particular heat transfer characteristics of various possible coolants including lithium, flibe, boiling alkali metals, and helium are discussed in the context of these general fusion reactor requirements. Some specific areas where further experimental and/or theoretical work is necessary are listed for each coolant along with references to the pertinent research already accomplished. Specialized heat transfer problems of the plasma injection and removal systems are also described. Finally, the challenging heat transfer problems associated with the superconducting magnets are reviewed, and once again some of the key unsolved heat transfer problems are enumerated

  3. Pressure control valve using proportional electro-magnetic solenoid actuator

    International Nuclear Information System (INIS)

    Yun, So Nam; Ham, Young Bog; Park, Pyoung Won

    2006-01-01

    This paper presents an experimental characteristics of electro-hydraulic proportional pressure control valve. In this study, poppet and valve body which are assembled into the proportional solenoid were designed and manufactured. The constant force characteristics of proportional solenoid actuator in the control region should be independent of the plunger position in order to be used to control the valve position in the fluid flow control system. The stroke-force characteristics of the proportional solenoid actuator is determined by the shape (or parameters) of the control cone. In this paper, steady state and transient characteristics of the solenoid actuator for electro-hydraulic proportional valve are analyzed using finite element method and it is confirmed that the proportional solenoid actuator has a constant attraction force in the control region independently on the stroke position. The effects of the parameters such as control cone length, thickness and taper length are also discussed

  4. Evaluation of the transfer of heat from the coil of the LHC dipole magnet to Helium II

    International Nuclear Information System (INIS)

    Richter, D.; Sevred, A.; Fleiter, J.; Baudouy, B.; Devred, A.

    2007-01-01

    During operation of the Large Hadron Collider at CERN, heat will be generated inside the coils of its superconducting magnets as a consequence of ramping of magnetic field, and of the interaction of lost beam particles with the magnet mass. Heat has to be transferred from the conductor into the He II coolant and removed from the magnet environment. During the LHC R and D stage, this transfer has been extensively studied on simulated coil segments at CEA/Saclay, and by analyzing dynamic behavior of short model magnets at CERN. Owing to the importance of efficient cooling for the design of future superconducting accelerator magnets, study of heat transfer has been restored at CERN and in frame of the Next European Dipole Collaboration. The article features two recently performed works: 1) Attempt to analyse archived high ramp rate quench data of 1-m-long LHC model dipole magnets of the 2. generation. 2) Development of a method for direct measurement of heat transfer on segments of production LHC dipole magnet coils. (authors)

  5. Heat transfer enhancement of Fe{sub 3}O{sub 4} ferrofluids in the presence of magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Fadaei, Farzad; Shahrokhi, Mohammad; Molaei Dehkordi, Asghar, E-mail: amolaeid@sharif.edu; Abbasi, Zeinab

    2017-05-01

    In this article, three-dimensional (3D) forced-convection heat transfer of magnetic nanofluids in a pipe subject to constant wall heat flux in the presence of single or double permanent magnet(s) or current-carrying wire has been investigated and compared. In this regard, laminar fluid flow and equilibrium magnetization for the ferrofluid were considered. In addition, variations of magnetic field in different media were taken into account and the assumption of having a linear relationship of magnetization with applied magnetic field intensity was also relaxed. Effects of magnetic field intensity, nanoparticle volume fraction, Reynolds number value, and the type of magnetic field source (i.e., a permanent magnet or current-carrying wire) on the forced-convection heat transfer of magnetic nanofluids were carefully investigated. It was found that by applying the magnetic field, the fluid mixing could be intensified that leads to an increase in the Nusselt number value along the pipe length. Moreover, the obtained simulation results indicate that applying the magnetic field induced by two permanent magnets with a magnetization of 3×10{sup 5} (A/m) (for each one), the fully developed Nusselt number value can be increased by 196%. - Highlights: • 3D forced-convection heat transfer of magnetic nanofluids is investigated. • Effects of single or double permanent magnet on the heat transfer are studied. • Influences of magnetic field induced by a current-carrying wire are studied. • Effects of magnetic field intensity and Reynolds number value are studied. • Variations of magnetic field in different media are taken into account.

  6. Spin transfer torque generated magnetic droplet solitons (invited)

    International Nuclear Information System (INIS)

    Chung, S.; Mohseni, S. M.; Sani, S. R.; Iacocca, E.; Dumas, R. K.; Pogoryelov, Ye.; Anh Nguyen, T. N.; Muduli, P. K.; Eklund, A.; Hoefer, M.; Åkerman, J.

    2014-01-01

    We present recent experimental and numerical advancements in the understanding of spin transfer torque generated magnetic droplet solitons. The experimental work focuses on nano-contact spin torque oscillators (NC-STOs) based on orthogonal (pseudo) spin valves where the Co fixed layer has an easy-plane anisotropy, and the [Co/Ni] free layer has a strong perpendicular magnetic anisotropy. The NC-STO resistance and microwave signal generation are measured simultaneously as a function of drive current and applied perpendicular magnetic field. Both exhibit dramatic transitions at a certain current dependent critical field value, where the microwave frequency drops 10 GHz, modulation sidebands appear, and the resistance exhibits a jump, while the magnetoresistance changes sign. We interpret these observations as the nucleation of a magnetic droplet soliton with a large fraction of its magnetization processing with an angle greater than 90°, i.e., around a direction opposite that of the applied field. This interpretation is corroborated by numerical simulations. When the field is further increased, we find that the droplet eventually collapses under the pressure from the Zeeman energy

  7. Graphene-ferromagnet interfaces: hybridization, magnetization and charge transfer.

    Science.gov (United States)

    Abtew, Tesfaye; Shih, Bi-Ching; Banerjee, Sarbajit; Zhang, Peihong

    2013-03-07

    Electronic and magnetic properties of graphene-ferromagnet interfaces are investigated using first-principles electronic structure methods in which a single layer graphene is adsorbed on Ni(111) and Co(111) surfaces. Due to the symmetry matching and orbital overlap, the hybridization between graphene pπ and Ni (or Co) d(z(2)) states is very strong. This pd hybridization, which is both spin and k dependent, greatly affects the electronic and magnetic properties of the interface, resulting in a significantly reduced (by about 20% for Ni and 10% for Co) local magnetic moment of the top ferromagnetic layer at the interface and an induced spin polarization on the graphene layer. The calculated induced magnetic moment on the graphene layer agrees well with a recent experiment. In addition, a substantial charge transfer across the graphene-ferromagnet interfaces is observed. We also investigate the effects of thickness of the ferromagnet slab on the calculated electronic and magnetic properties of the interface. The strength of the pd hybridization and the thickness-dependent interfacial properties may be exploited to design structures with desirable magnetic and transport properties for spintronic applications.

  8. Optimal design of implants for magnetically mediated hyperthermia: A wireless power transfer approach

    Science.gov (United States)

    Lang, Hans-Dieter; Sarris, Costas D.

    2017-09-01

    In magnetically mediated hyperthermia (MMH), an externally applied alternating magnetic field interacts with a mediator (such as a magnetic nanoparticle or an implant) inside the body to heat up the tissue in its proximity. Producing heat via induced currents in this manner is strikingly similar to wireless power transfer (WPT) for implants, where power is transferred from a transmitter outside of the body to an implanted receiver, in most cases via magnetic fields as well. Leveraging this analogy, a systematic method to design MMH implants for optimal heating efficiency is introduced, akin to the design of WPT systems for optimal power transfer efficiency. This paper provides analytical formulas for the achievable heating efficiency bounds as well as the optimal operating frequency and the implant material. Multiphysics simulations validate the approach and further demonstrate that optimization with respect to maximum heating efficiency is accompanied by minimizing heat delivery to healthy tissue. This is a property that is highly desirable when considering MMH as a key component or complementary method of cancer treatment and other applications.

  9. The magnetization transfer characteristics of human breast tissues: an in vitro NMR study

    Science.gov (United States)

    Callicott, C.; Thomas, J. M.; Goode, A. W.

    1999-05-01

    A series of freshly excised human breast tissues was analysed using a nuclear magnetic resonance spectrometer and then subjected to routine histopathology examination. Tissues comprised normal parenchymal, adipose, fibrocystic, fibroadenoma and malignant types. An inversion-recovery sequence performed both with and without magnetization transfer allowed T1, T1, and values to be obtained. From this information, the magnetization transfer rate constant, K, was calculated for each tissue sample. These data show that T1 provided greater discrimination between neoplasic and normal tissues than did T1. However, neither T1 nor K values provided a means of discriminating between benign and malignant disease.

  10. Accurate magnetic field calculations for contactless energy transfer coils

    NARCIS (Netherlands)

    Sonntag, C.L.W.; Spree, M.; Lomonova, E.A.; Duarte, J.L.; Vandenput, A.J.A.

    2007-01-01

    In this paper, a method for estimating the magnetic field intensity from hexagon spiral windings commonly found in contactless energy transfer applications is presented. The hexagonal structures are modeled in a magneto-static environment using Biot-Savart current stick vectors. The accuracy of the

  11. A quantitative study of ramped radio frequency, magnetization transfer, and slab thickness in three-dimensional time-of-flight magnetic resonance angiography in a patient population.

    Science.gov (United States)

    Goodrich, K C; Blatter, D D; Parker, D L; Du, Y P; Meyer, K J; Bernstein, M A

    1996-06-01

    The authors compare the effectiveness of various magnetic resonance (MR) angiography acquisition strategies in enhancing the visibility of small intracranial vessels. Blood vessel contrast-to-noise ratio (CNR) in time-of-flight MR angiography was studied as a function of vessel size and several selectable imaging parameters. Contrast-to-noise measurements were made on 257 vessel segments ranging in size from 0.3 mm to 4.2 mm in patients who recently had undergone intraarterial cerebral angiography. Imaging parameters studied included magnetization transfer, spatially variable radio frequency (RF) pulse profile (ramped RF), and imaging slab thickness. The combination of thin slabs (16 slices/slab), ramped RF, and magnetization transfer resulted in the highest CNR for all but the smallest vessel sizes. The smallest vessels (slab (64 slices/slab) with ramped RF and magnetization transfer. Magnetization transfer always improved vessel CNR, but the improvement diminished as the slab thickness was reduced. The CNR increased with a decrease in slab thickness for all but the smallest vessel sizes. Overall, the results provide a quantitative demonstration that inflow enhancement of blood is reduced for small vessels. Thus, whereas magnetization transfer is important at all vessel sizes, it becomes the primary factor in improving the visibility of the smallest vessels.

  12. Position sensitive proportional counters as focal plane detectors

    International Nuclear Information System (INIS)

    Ford, J.L.C. Jr.

    1979-01-01

    The rise time and charge division techniques for position decoding with RC-line proportional counters are reviewed. The advantages that these detectors offer as focal plane counters for nuclear spectroscopy performed with magnetic spectrographs are discussed. The theory of operation of proportional counters as position sensing devices is summarized, as well as practical aspects affecting their application. Factors limiting the position and energy resolutions obtainable with a focal plane proportional counter are evaluated and measured position and energy loss values are presented for comparison. Detector systems capable of the multiparameter measurements required for particle identification, background suppression and ray-tracing are described in order to illustrate the wide applicability of proportional counters within complex focal plane systems. Examples of the use of these counters other than with magnetic spectrographs are given in order to demonstrate their usefulness in not only nuclear physics but also in fields such as solid state physics, biology, and medicine. The influence of the new focal plane detector systems on future magnetic spectrograph designs is discussed. (Auth.)

  13. Layered Black Phosphorus: Strongly Anisotropic Magnetic, Electronic, and Electron-Transfer Properties.

    Science.gov (United States)

    Sofer, Zdeněk; Sedmidubský, David; Huber, Štěpán; Luxa, Jan; Bouša, Daniel; Boothroyd, Chris; Pumera, Martin

    2016-03-01

    Layered elemental materials, such as black phosphorus, exhibit unique properties originating from their highly anisotropic layered structure. The results presented herein demonstrate an anomalous anisotropy for the electrical, magnetic, and electrochemical properties of black phosphorus. It is shown that heterogeneous electron transfer from black phosphorus to outer- and inner-sphere molecular probes is highly anisotropic. The electron-transfer rates differ at the basal and edge planes. These unusual properties were interpreted by means of calculations, manifesting the metallic character of the edge planes as compared to the semiconducting properties of the basal plane. This indicates that black phosphorus belongs to a group of materials known as topological insulators. Consequently, these effects render the magnetic properties highly anisotropic, as both diamagnetic and paramagnetic behavior can be observed depending on the orientation in the magnetic field. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Electronics for proportional drift tubes

    International Nuclear Information System (INIS)

    Fremont, G.; Friend, B.; Mess, K.H.; Schmidt-Parzefall, W.; Tarle, J.C.; Verweij, H.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration); Geske, K.; Riege, H.; Schuett, J.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration); Semenov, Y.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration)

    1980-01-01

    An electronic system for the read-out of a large number of proportional drift tubes (16,000) has been designed. This system measures deposited charge and drift-time of the charge of a particle traversing a proportional drift tube. A second event can be accepted during the read-out of the system. Up to 40 typical events can be collected and buffered before a data transfer to a computer is necessary. (orig.)

  15. Spin-transfer phenomena in layered magnetic structures: Physical phenomena and materials aspects

    International Nuclear Information System (INIS)

    Gruenberg, P.; Buergler, D.E.; Dassow, H.; Rata, A.D.; Schneider, C.M.

    2007-01-01

    During the past 20 years, layered structures consisting of ferromagnetic layers and spacers of various material classes with a thickness of only a few nanometers have revealed a variety of exciting and potentially very useful phenomena not present in bulk material. Representing distinct manifestations of spin-transfer processes, these phenomena may be categorized into interlayer exchange coupling (IEC), giant magnetoresistance (GMR), tunneling magnetoresistance (TMR), and the more recently discovered spin-transfer torque effect leading to current-induced magnetization switching (CIMS) and current-driven magnetization dynamics. These phenomena clearly confer novel material properties on magnetic layered structures with respect to the (magneto-)transport and the magnetostatic as well as magnetodynamic behavior. Here, we will first concentrate on the less well understood aspects of IEC across insulating and semiconducting interlayers and relate the observations to TMR in the corresponding structures. In this context, we will also discuss more recent advances in TMR due to the use of electrodes made from Heusler alloys and the realization of coherent tunneling in epitaxial magnetic tunneling junctions. Finally, we will review our results on CIMS in epitaxial magnetic nanostructures showing that normal and inverse CIMS can occur simultaneously in a single nanopillar device. In all cases discussed, material issues play a major role in the detailed understanding of the spin-transfer effects, in particular in those systems that yield the largest effects and are thus of utmost interest for applications

  16. Regional analysis of the magnetization transfer ratio of the brain in mild Alzheimer disease and amnestic mild cognitive impairment.

    Science.gov (United States)

    Mascalchi, M; Ginestroni, A; Bessi, V; Toschi, N; Padiglioni, S; Ciulli, S; Tessa, C; Giannelli, M; Bracco, L; Diciotti, S

    2013-01-01

    Manually drawn VOI-based analysis shows a decrease in magnetization transfer ratio in the hippocampus of patients with Alzheimer disease. We investigated with whole-brain voxelwise analysis the regional changes of the magnetization transfer ratio in patients with mild Alzheimer disease and patients with amnestic mild cognitive impairment. Twenty patients with mild Alzheimer disease, 27 patients with amnestic mild cognitive impairment, and 30 healthy elderly control subjects were examined with high-resolution T1WI and 3-mm-thick magnetization transfer images. Whole-brain voxelwise analysis of magnetization transfer ratio maps was performed by use of Statistical Parametric Mapping 8 software and was supplemented by the analysis of the magnetization transfer ratio in FreeSurfer parcellation-derived VOIs. Voxelwise analysis showed 2 clusters of significantly decreased magnetization transfer ratio in the left hippocampus and amygdala and in the left posterior mesial temporal cortex (fusiform gyrus) of patients with Alzheimer disease as compared with control subjects but no difference between patients with amnestic mild cognitive impairment and either patients with Alzheimer disease or control subjects. VOI analysis showed that the magnetization transfer ratio in the hippocampus and amygdala was significantly lower (bilaterally) in patients with Alzheimer disease when compared with control subjects (ANOVA with Bonferroni correction, at P ratio values in the hippocampus and amygdala in patients with amnestic mild cognitive impairment were between those of healthy control subjects and those of patients with mild Alzheimer disease. Support vector machine-based classification demonstrated improved classification performance after inclusion of magnetization transfer ratio-related features, especially between patients with Alzheimer disease versus healthy subjects. Bilateral but asymmetric decrease of magnetization transfer ratio reflecting microstructural changes of the

  17. Assisted Writing in Spin Transfer Torque Magnetic Tunnel Junctions

    Science.gov (United States)

    Ganguly, Samiran; Ahmed, Zeeshan; Datta, Supriyo; Marinero, Ernesto E.

    2015-03-01

    Spin transfer torque driven MRAM devices are now in an advanced state of development, and the importance of reducing the current requirement for writing information is well recognized. Different approaches to assist the writing process have been proposed such as spin orbit torque, spin Hall effect, voltage controlled magnetic anisotropy and thermal excitation. In this work,we report on our comparative study using the Spin-Circuit Approach regarding the total energy, the switching speed and energy-delay products for different assisted writing approaches in STT-MTJ devices using PMA magnets.

  18. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Rovira, A.; Alonso, J.; Cucurella, G.; Nos, C.; Tintore, M.; Pedraza, S.; Rio, J.; Montalban, X.

    1997-01-01

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs

  19. The magnetization transfer characteristics of human breast tissues: an in vitro NMR study

    International Nuclear Information System (INIS)

    Callicott, C.; Thomas, J.M.; Goode, A.W.

    1999-01-01

    A series of freshly excised human breast tissues was analysed using a nuclear magnetic resonance spectrometer and then subjected to routine histopathology examination. Tissues comprised normal parenchymal, adipose, fibrocystic, fibroadenoma and malignant types. An inversion-recovery sequence performed both with and without magnetization transfer allowed T1, T1 5 , M o and M 5 values to be obtained. From this information, the magnetization transfer rate constant, K, was calculated for each tissue sample. These data show that T1 5 provided greater discrimination between neoplasic and normal tissues than did T1. However, neither T1 5 nor K values provided a means of discriminating between benign and malignant disease. (author)

  20. Magnetic resonance findings in amyotrophic lateral sclerosis using a spin echo magnetization transfer sequence: preliminary report

    Directory of Open Access Journals (Sweden)

    ROCHA ANTÔNIO JOSÉ DA

    1999-01-01

    Full Text Available We present the magnetic resonance (MR findings of five patients with amyotrophic lateral sclerosis (ALS using a spin-echo sequence with an additional magnetization transfer (MT pulse on T1-weighted images (T1 SE/MT. These findings were absent in the control group and consisted of hyperintensity of the corticospinal tract. Moreover we discuss the principles and the use of this fast but simple MR technique in the diagnosis of ALS

  1. Alignment Compensation for Bending Radius in TI 2 Transfer Line Magnets

    CERN Document Server

    Weterings, W

    2004-01-01

    The optics file for the TI 2 transfer lines specifies the position of the bending magnets assuming that the beam enters and exists at the centre of the vacuum pipe. In order to disbribute the deflected beam evenly inside the vacuum tube, the alignment has to be compensated by moving the magnets half of the beam deflection away from the centre of the bending radius. In this note the saggitas of the various TI 2 magnets are calculated and the alignment displacements tabulated for future reference.

  2. Magnetization transfer on T2-weighted image : magnetization Transfer ratios in normal brain and cerebral lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Myung Kwan; Roh, Hong Gee; Suh, Chang Hae; Cho, Young Kook; Kim, Hyung Jin; Kim, Jin Hee; Kim, Sung Tae; Choi, Sung Kyu [Inha Univ. College of Medicine, Incheon (Korea, Republic of)

    1998-07-01

    To evaluate the magnetization transfer ratio(MTR) of various normal structures and pathologic lesions, as seen on magnetization transfer T2-weighted images (MT+T2WI). Materials and Methods : In ten normal volunteers, T2-weighted images without MT (MT-T2WI) and with MT(MT+T2WI) were obtained. Off-set pulses used in MT+T2WI were 400, 600, 1000, 1500, and 2000Hz. In 60 clinical cases infarction(n=10), brain tumors(n=5), traumatic hematomas(n=5), other hematomas(n=3) vascular malformation(n=2) white matter disease(n=2) normal(n=31) and others(n=2), both MT-T2WI and MT+T2WI images were obtained using an off-set pulse of 600 Hz. In all volunteers and patients, MTR in various normal brain parenchyma and abnormal areas was measured. Results : The MTRs of white and gray matter were 48% and 45% respectively at 400 Hz, 26% and 22% at 600Hz, 12% and 11% of 1000Hz, 10% and 9% 1500HZ, and 9% and 8% at 2000Hz of RF. The MTR of CSF was 43% at 400 Hz of off-resonance RF, while the contrast resolution of T2WI was poor. An off-resonance of 600Hz appeared to be the optimal frequency. In diseased areas,MTRs varied but were usually similar to or lower than those of brain parenchyma. Conclusion : The optimal off-resonance RF on MT+T2WI appears to be 600 Hz for relatively high MTR of brain parenchyma and low MTR of CSF,in which MTRs of white and gray matter were 26% and 22%, respectively, of 600Hz off-set pulse. The MTRs of cerebral lesions varied and further studies of various cerebral lesions are needed.

  3. Spin and energy transfer between magnetic ions and free carriers in diluted-magnetic semiconductor heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Yakovlev, D.R. [Experimental Physics 2, University of Dortmund, 44227 Dortmund (Germany); Ioffe Physico-Technical Institute, Russian Academy of Sciences, 194021 St. Petersburg (Russian Federation); Kneip, M.; Bayer, M. [Experimental Physics 2, University of Dortmund, 44227 Dortmund (Germany); Maksimov, A.A.; Tartakovskii, I.I. [Institute of Solid State Physics, Russian Academy of Sciences, 142432 Chernogolovka (Russian Federation); Keller, D.; Ossau, W.; Molenkamp, L.W. [Physikalisches Institut der Universitaet Wuerzburg, 97074 Wuerzburg (Germany); Scherbakov, A.V.; Akimov, A.V. [Ioffe Physico-Technical Institute, Russian Academy of Sciences, 194021 St. Petersburg (Russian Federation); Waag, A. [Abteilung Halbleiterphysik, Universitaet Ulm, 89081 Ulm (Germany)

    2004-03-01

    In this paper we give a brief overview of our studies on dynamical processes in diluted-magnetic-semiconductor heterostructures based on (Zn,Mn)Se and (Cd,Mn)Te. Presence of free carriers is an important factor which determines the energy- and spin transfer in a coupled systems of magnetic ions, lattice (the phonon system) and carriers. We report also new data on dynamical response of magnetic ions interacting with photogenerated electron-hole plasma. (Zn,Mn)Se/(Zn,Be)Se structures with relatively high Mn content of 11% provide spin-lattice relaxation time of about 20 ns, which is considerably shorter then the characteristic times of nonequilibrium phonons ranging to 1 {mu}s. (copyright 2004 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. Coherent population transfer in multilevel systems with magnetic sublevels. II. Algebraic analysis

    International Nuclear Information System (INIS)

    Martin, J.; Shore, B.W.; Bergmann, K.

    1995-01-01

    We extend previous theoretical work on coherent population transfer by stimulated Raman adiabatic passage for states involving nonzero angular momentum. The pump and Stokes fields are either copropagating or counterpropagating with the corresponding linearly polarized electric-field vectors lying in a common plane with the magnetic-field direction. Zeeman splitting lifts the magnetic sublevel degeneracy. We present an algebraic analysis of dressed-state properties to explain the behavior noted in numerical studies. In particular, we discuss conditions which are likely to lead to a failure of complete population transfer. The applied strategy, based on simple methods of linear algebra, will also be successful for other types of discrete multilevel systems, provided the rotating-wave and adiabatic approximation are valid

  5. Coherent population transfer in multilevel systems with magnetic sublevels. II. Algebraic analysis

    Science.gov (United States)

    Martin, J.; Shore, B. W.; Bergmann, K.

    1995-07-01

    We extend previous theoretical work on coherent population transfer by stimulated Raman adiabatic passage for states involving nonzero angular momentum. The pump and Stokes fields are either copropagating or counterpropagating with the corresponding linearly polarized electric-field vectors lying in a common plane with the magnetic-field direction. Zeeman splitting lifts the magnetic sublevel degeneracy. We present an algebraic analysis of dressed-state properties to explain the behavior noted in numerical studies. In particular, we discuss conditions which are likely to lead to a failure of complete population transfer. The applied strategy, based on simple methods of linear algebra, will also be successful for other types of discrete multilevel systems, provided the rotating-wave and adiabatic approximation are valid.

  6. Magnetic field emission comparison at different quality factors with series-series compensation network for inductive power transfer to vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Inductive power transfer is non-contact transfer of energy by means of magnetic fields. A higher secondary side quality factor at fixed input current ensures a linear increase in power transfer across the air gap. But also at the same time magnetic emissions to the surroundings increase. First...... of all in this paper an analytic expression for comparing the magnetic emissions at different quality factors is introduced. It is shown with help of simulations on Comsol that emissions have a lower increase as compared to linear increase in the power transferred with the quality factor as suggested...

  7. Heat transfer from aluminum to He II: application to superconductive magnetic energy storage

    International Nuclear Information System (INIS)

    Van Sciver, S.W.; Boom, R.W.

    1979-01-01

    Heat transfer problems associated with large scale Superconductive Magnetic Energy Storage (SMES) are unique due to the proposed size of a unit. The Wisconsin design consists of a cryogenically stable magnet cooled with He II at 1.8 K. The special properties of He II (T 2 at 1.91 K and a recovery at 0.7 W/cm 2 . The advantages of operating the magnet under subcooled conditions are exemplified by improved heat transfer. The maximum at 1.89 K and 1.3 atm pressure is 2.3 W/cm 2 with recovery enhanced to 1.9 W/cm 2 . A conservative maximum heat flux of 0.5 W/cm 2 with an associated temperature difference of 0.5 K has been chosen for design. Elements of the experimental study as well as the design will be discussed

  8. Magnetization rotation or generation of incoherent spin waves? Suggestions for a spin-transfer effect experiment

    International Nuclear Information System (INIS)

    Bazaliy, Y. B.; Jones, B. A.

    2002-01-01

    ''Spin-transfer'' torque is created when electric current is passed through metallic ferromagnets and may have interesting applications in spintronics. So far it was experimentally studied in ''collinear'' geometries, where it is difficult to predict whether magnetization will coherently rotate or spin-waves will be generated. Here we propose an easy modification of existing experiment in which the spin-polarization of incoming current will no longer be collinear with magnetization and recalculate the switching behavior of the device. We expect that a better agreement with the magnetization rotation theory will be achieved. That can be an important step in reconciling alternative points of view on the effect of spin-transfer torque

  9. Studies on MHD pressure drop and heat transfer of helium-lithium annular-mist flow in a transverse magnetic field

    International Nuclear Information System (INIS)

    Inoue, Akira; Aritomi, Masanori; Takahashi, Minoru; Matsuzaki, Mitsuo; Narita, Yoshihito; Yano, Toshikazu.

    1987-01-01

    Pressure drop and heat transfer coefficient of helium-lithium annular-mist flow in a rectangular duct were investigated experimentally under a transverse magnetic field at system pressure of 0.2 MPa. A ratio of MHD pressure drop to that of non-magnetic field increases with magnetic flux density and a mass flow rate ratio of lithium to helium in low helium velocity region. However, as increasing the helium velocity, the increment of MHD pressure drop with the magnetic flux density is much reduced and then becomes almost zero. At this condition, the MHD pressure drop of the annular-mist flow becomes much smaller than that of lithium single phase flow with the same lithium mass flow at the high magnetic flux density. Heat transfer coefficient ratio of the helium-lithium annular-mist flow to helium single phase in the non-magnetic field is well correlated by a ratio of the mass flow rate of lithium to helium. The heat transfer coefficient in the magnetic field increases with the magnetic flux density and then terminates at a certain value depending on the mass flow rate ratio and the helium velocity. These characteristics of the MHD pressure drop and the heat transfer in the magnetic field suggest that the helium-lithium annular-mist flow is effectively applicable to cooling of the high heat flux wall in a strong magnetic field like a first wall of a magnetic confinement fusion reactors. (author)

  10. Evaluation of magnetization transfer ratios for breast tissues and breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Fumio; Murai, Hiroshi; Takeuchi, Thouru; Iwase, Takuji; Miura, Shigeto; Mastushima, Shigeru; Oosaki, Hikaru [Aichi Cancer Center, Nagoya (Japan). Hospital; Kinosada, Yasuomi

    1997-03-01

    To determine MTRs for normal structures and benign diseases in the breast two-dimensional magnetization transfer imaging was performed in 62 patients and in 3 young female volunteers. With regard to the MTRs of measurements in the normal breast tissues, fat tissues which is close to simple cysts in MTRs show little transfer of longitudinal magnetization. MTRs of the muscles was 15.15{+-}6.22%, which exceeded those of breast parenchyma. The breast parenchyma didn`t show the change of MTR value due to the difference of patient age and due to variable amount of fat and fibrous tissues. Breast parenchyma in the two young volunteers clearly showed biphasic change of MTR values in accordance with the menstrual cycle; little transfer value was due to hydration in the postovulatory period and high transfer value was due to dehydration in the preovulatory period. In the remaining one volunteer during lactation period, mammary parenchyma shows sever decrease in MTR, because mammary gland is loaded with massive fluid, showing a very high signal intensity on First IR and T2-weighted images. MTR values of benign breast diseases including mastopathy, fibroadenoma and phyllodes tumor had no significant difference from those of the breast parenchyma and muscle. Non-invasive ductal carcinoma was equivalent to breast parenchyma in MTR. (K.H.)

  11. Enhancement in heat transfer of a ferrofluid in a differentially heated square cavity through the use of permanent magnets

    Science.gov (United States)

    Joubert, J. C.; Sharifpur, M.; Solomon, A. Brusly; Meyer, J. P.

    2017-12-01

    The natural convection heat transfer of a magnetic nanofluid in a differentially heated cavity is investigated with and without an applied external magnetic field. The effects of volume fraction, magnetic field configuration, and magnetic field strength are investigated. Spherical Fe2O3 nanoparticles with a diameter of 15-20 nm are used in the nanofluids. Volume fractions ranging between 0.05% and 0.3% are tested for the case with no magnetic field, while only a volume fraction of 0.1% was tested in an externally applied magnetic field. The experiments were conducted for a range of Rayleigh numbers in 1.7 × 108 < Ra < 4.2 × 108. The viscosity of the nanofluid was determined experimentally. An empirical correlation for the viscosity was determined, and the stability of various nanofluids was investigated. Using heat transfer data obtained from the cavity, the average heat transfer coefficient and average Nusselt number for the nanofluids are determined. It was found that a volume fraction of 0.1% showed a maximum increase of 5.63% to the Nu at the maximum Ra. For the magnetic field study, it was found that the best-performing magnetic field enhanced the heat transfer behaviour by an additional 2.81% in Nu at Ra = 3.8 × 108.

  12. Anisotropic temperature relaxation of plasmas in an external magnetic field

    International Nuclear Information System (INIS)

    Hassan, M.H.A.

    1977-01-01

    The magnetized kinetic equation derived in an earlier paper (Hassan and Watson, 1977) is used to study the problem of relaxation of anisotropic electron and ion temperatures in a magnetized plasma. In the case of anisotropic electron temperature relaxation, it is shown that for small anisotropies the exchange of energy within the electrons between the components parallel and perpendicular to the magnetic field direction determine the relaxation rate. For anisotropic ion temperature relaxation it is shown that the essential mechanism for relaxation is provided by energy transfer between ions and electrons, and that the expression for the relaxation rate perpendicular to the magnetic field contains a significant term proportional to ln eta 0 ln (msub(e)/msub(i)) (where eta 0 = Ωsub(e)/ksub(D)Vsub(e perpendicular to)), in addition to the term proportional to the Coulomb logarithm. (author)

  13. Magnetic Field Emissions for Ferrite and Non-Ferrite Geometries for Wireless Power Transfer to Vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Minimizing magnetic field emissions to surroundings is one of the most challenging design criteria for wireless power transfer to vehicles. In this paper, concept of division of the emissions into three zones (primary, secondary, and combined zone) in the vertical direction is introduced. For geo......Minimizing magnetic field emissions to surroundings is one of the most challenging design criteria for wireless power transfer to vehicles. In this paper, concept of division of the emissions into three zones (primary, secondary, and combined zone) in the vertical direction is introduced...... for vertical separation between the coils in range of 100-180 mm. It is observed that lower vertical separation results in higher overlapping of the zones and the coils behave as they are effectively placed close to center of air gap. The analysis in this work provides a better understanding of the space...... profile of magnetic field emissions (with and without ferrite) for wireless power transfer to vehicles....

  14. Magnetic field concentration using ferromagnetic material to propel a wireless power transfer based micro-robot

    Directory of Open Access Journals (Sweden)

    Dongwook Kim

    2018-05-01

    Full Text Available In this paper, we propose a novel coil structure, using a ferromagnetic material which concentrates the magnetic field, as the propulsion system of a wireless power transfer (WPT based micro-robot. This structure uses an incident magnetic field to induce current during wireless power transfer, to generate a Lorentz force. To prevent net cancelation of the Lorentz force in the load coil, ferrite films were applied to one side of the coil segment. The demonstrated simplicity and effectiveness of the proposed micro-robot showed its suitability for applications. Simulation and experimental results confirmed a velocity of 1.02 mm/s with 6 mW power transfer capacity for the 3 mm sized micro-robot.

  15. Magnetic field concentration using ferromagnetic material to propel a wireless power transfer based micro-robot

    Science.gov (United States)

    Kim, Dongwook; Park, Bumjin; Park, Jaehyoung; Park, Hyun Ho; Ahn, Seungyoung

    2018-05-01

    In this paper, we propose a novel coil structure, using a ferromagnetic material which concentrates the magnetic field, as the propulsion system of a wireless power transfer (WPT) based micro-robot. This structure uses an incident magnetic field to induce current during wireless power transfer, to generate a Lorentz force. To prevent net cancelation of the Lorentz force in the load coil, ferrite films were applied to one side of the coil segment. The demonstrated simplicity and effectiveness of the proposed micro-robot showed its suitability for applications. Simulation and experimental results confirmed a velocity of 1.02 mm/s with 6 mW power transfer capacity for the 3 mm sized micro-robot.

  16. The effect of magnetic field on instabilities of heat transfer from an obstacle in a channel

    International Nuclear Information System (INIS)

    Rashidi, S.; Esfahani, J.A.

    2015-01-01

    This paper presents forced convective heat transfer in a channel with a built-in square obstacle. The governing equations with the boundary conditions are solved using a finite volume method. The computations were done for a fixed blockage ratio (S=1/8) at Pr=0.71, and Reynolds (Re) and Stuart (N) numbers ranging from 1 to 250 and 0 to 10, respectively. The results are presented to show the effect of the channel walls and streamwise magnetic field at different Reynolds numbers on forced convection heat transfer from a square cylinder. A correlation is obtained for Nusselt number, in which the effect of a magnetic field is taken into account. The obtained results revealed that the existence of channel walls decreases the effects of magnetic field on Nusselt number. It also showed that by increasing Stuart number the thickness of thermal boundary layer increases and the convective heat transfer decreases. - Highlights: • The magnetic field is used to control the instabilities of heat transfer. • The thickness of thermal boundary layer increases by increasing Stuart number. • Unsteadiness in temperature field increases with increase in Reynolds number. • Time-averaged Nusselt number decreases with increase in Stuart number. • The Lorentz forces are much denser near the surface of the obstacle

  17. State diagram of a perpendicular magnetic tunnel junction driven by spin transfer torque: A power dissipation approach

    Energy Technology Data Exchange (ETDEWEB)

    Lavanant, M. [Institut Jean Lamour, UMR CNRS 7198 – Université de Lorraine, Nancy (France); Department of Physics, New York University, New York, NY 10003 (United States); Petit-Watelot, S. [Institut Jean Lamour, UMR CNRS 7198 – Université de Lorraine, Nancy (France); Kent, A.D. [Department of Physics, New York University, New York, NY 10003 (United States); Mangin, S., E-mail: stephane.mangin@univ-lorraine.fr [Institut Jean Lamour, UMR CNRS 7198 – Université de Lorraine, Nancy (France)

    2017-04-15

    The state diagram of a magnetic tunnel junction with perpendicularly magnetized electrodes in the presence of spin-transfer torques is computed in a macrospin approximation using a power dissipation model. Starting from the macrospin's energy we determine the stability of energy extremum in terms of power received and dissipated, allowing the consideration of non-conservative torques associated with spin transfer and damping. The results are shown to be in agreement with those obtained by direct integration of the Landau-Lifshitz-Gilbert-Slonczewski equation. However, the power dissipation model approach is faster and shows the reason certain magnetic states are stable, such as states that are energy maxima but are stabilized by spin transfer torque. Breaking the axial system, such as by a tilted applied field or tilted anisotropy, is shown to dramatically affect the state diagrams. Finally, the influence of a higher order uniaxial anisotropy that can stabilize a canted magnetization state is considered and the results are compared to experimental data. - Highlights: • Methods to compute state Diagram (Voltage Versus Field) for perpendicular Magnetic Tunnel Junctions. • Comparison between the conventional LLG model and a model based on Power dissipation to study magnetization reversal in magnetic tunnel junction.

  18. Magnetization transfer ratio relates to cognitive impairment in normal elderly

    Directory of Open Access Journals (Sweden)

    Stephan eSeiler

    2014-09-01

    Full Text Available Magnetization transfer imaging (MTI can detect microstructural brain tissue changes and may be helpful in determining age-related cerebral damage. We investigated the association between the magnetization transfer ratio (MTR in gray and white matter and cognitive functioning in 355 participants of the Austrian Stroke Prevention Family Study (ASPS-Fam aged 38 to 86 years. MTR maps were generated for the neocortex, deep gray matter structures, white matter hyperintensities, and normal appearing white matter. Adjusted mixed models determined whole brain and lobar cortical MTR to be directly and significantly related to performance on tests of memory, executive function and motor skills. There existed an almost linear dose-effect relationship. MTR of deep gray matter structures and normal appearing white matter correlated to executive functioning. All associations were independent of demographics, vascular risk factors, focal brain lesions and cortex volume.Further research is needed to understand the basis of this association at the tissue level, and to determine the role of MTR in predicting cognitive decline and dementia.

  19. Blockage effects on viscous fluid flow and heat transfer past a magnetic obstacle in a duct

    International Nuclear Information System (INIS)

    Zhang Xi-Dong; Huang Hu-Lin

    2013-01-01

    The effect of lateral walls on fluid flow and heat transfer is investigated when a fluid passes a magnetic obstacle. The blockage ratio β that represents the ratio between the width of external magnet M y and the spanwise width L y is employed to depict the effect. The finite volume method (FVM) based on the PISO algorithm is applied for the blockage ratios of 0.2, 0.3, and 0.4. The results show that the value of Strouhal number St increases as the blockage ratio β increases, and for small β, the variation of St is very small when the interaction parameter and Reynolds number are increasing. Moreover, the cross-stream mixing induced by the magnetic obstacle can enhance the wall-heat transfer and the maximum value of the overall heat transfer increment is about 50.5%

  20. Technology transfer for industrial production of superconducting magnets for the RHIC project at BNL

    International Nuclear Information System (INIS)

    Wanderer, P.; Anerella, M.D.; Greene, A.F.; Kelly, E.; Willen, E.

    1994-01-01

    Industrial production of superconducting magnets for the Relativistic Heavy Ion Collider (RHIC) has begun. The R ampersand D for the magnets was carried out at BNL. Following the award of built-to-print contracts, staff from the laboratory and the vendors worked toward transferring both design principles and practical details to an industrial framework for cost effective production. All magnets made thus far have been acceptable for use in RHIC

  1. Electric-field control of magnetism via strain transfer across ferromagnetic/ferroelectric interfaces.

    Science.gov (United States)

    Taniyama, Tomoyasu

    2015-12-23

    By taking advantage of the coupling between magnetism and ferroelectricity, ferromagnetic (FM)/ferroelectric (FE) multiferroic interfaces play a pivotal role in manipulating magnetism by electric fields. Integrating the multiferroic heterostructures into spintronic devices significantly reduces energy dissipation from Joule heating because only an electric field is required to switch the magnetic element. New concepts of storage and processing of information thus can be envisioned when the electric-field control of magnetism is a viable alternative to the traditional current based means of controlling magnetism. This article reviews some salient aspects of the electric-field effects on magnetism, providing a short overview of the mechanisms of magneto-electric (ME) coupling at the FM/FE interfaces. A particular emphasis is placed on the ME effect via interfacial magneto-elastic coupling arising from strain transfer from the FE to FM layer. Recent results that demonstrate the electric-field control of magnetic anisotropy, magnetic order, magnetic domain wall motion, and etc are described. Obstacles that need to be overcome are also discussed for making this a reality for future device applications.

  2. Electric-field control of magnetism via strain transfer across ferromagnetic/ferroelectric interfaces

    International Nuclear Information System (INIS)

    Taniyama, Tomoyasu

    2015-01-01

    By taking advantage of the coupling between magnetism and ferroelectricity, ferromagnetic (FM)/ferroelectric (FE) multiferroic interfaces play a pivotal role in manipulating magnetism by electric fields. Integrating the multiferroic heterostructures into spintronic devices significantly reduces energy dissipation from Joule heating because only an electric field is required to switch the magnetic element. New concepts of storage and processing of information thus can be envisioned when the electric-field control of magnetism is a viable alternative to the traditional current based means of controlling magnetism. This article reviews some salient aspects of the electric-field effects on magnetism, providing a short overview of the mechanisms of magneto-electric (ME) coupling at the FM/FE interfaces. A particular emphasis is placed on the ME effect via interfacial magneto-elastic coupling arising from strain transfer from the FE to FM layer. Recent results that demonstrate the electric-field control of magnetic anisotropy, magnetic order, magnetic domain wall motion, and etc are described. Obstacles that need to be overcome are also discussed for making this a reality for future device applications. (topical review)

  3. Experimental study on heat transfer enhancement of laminar ferrofluid flow in horizontal tube partially filled porous media under fixed parallel magnet bars

    Energy Technology Data Exchange (ETDEWEB)

    Sheikhnejad, Yahya; Hosseini, Reza, E-mail: hoseinir@aut.ac.ir; Saffar Avval, Majid

    2017-02-15

    In this study, steady state laminar ferroconvection through circular horizontal tube partially filled with porous media under constant heat flux is experimentally investigated. Transverse magnetic fields were applied on ferrofluid flow by two fixed parallel magnet bar positioned on a certain distance from beginning of the test section. The results show promising notable enhancement in heat transfer as a consequence of partially filled porous media and magnetic field, up to 2.2 and 1.4 fold enhancement were observed in heat transfer coefficient respectively. It was found that presence of both porous media and magnetic field simultaneously can highly improve heat transfer up to 2.4 fold. Porous media of course plays a major role in this configuration. Virtually, application of Magnetic field and porous media also insert higher pressure loss along the pipe which again porous media contribution is higher that magnetic field. - Highlights: • Porous media can improve the coefficient of heat transfer up to 2.2 fold. • Both porous media and Nano particles have undesired pressure drop effect. • Application of both porous media and magnetic field in ferrofluid flow will result in significant enhancement in heat transfer up to 2.4 fold. • Magnet bar effect is mainly restricted to approximately one fourth of the test section. • Diluted Ferrofluids 2%, results in over 1.4 fold enhancement in heat transfer coefficient.

  4. Poynting vector analysis for wireless power transfer between magnetically coupled coils with different loads.

    Science.gov (United States)

    Guo, Yunsheng; Li, Jiansheng; Hou, Xiaojuan; Lv, Xiaolong; Liang, Hao; Zhou, Ji; Wu, Hongya

    2017-04-07

    Wireless power transfer is a nonradiative type of transmission that is performed in the near-field region. In this region, the electromagnetic fields that are produced by both the transmitting and receiving coils are evanescent fields, which should not transmit energy. This then raises the question of how the energy can be transferred. Here we describe a theoretical study of the two evanescent field distributions at different terminal loads. It is shown that the essential principle of wireless energy transfer is the superposition of the two evanescent fields, and the resulting superimposed field is mediated through the terminal load. If the terminal load is either capacitive or inductive, then the superimposed field cannot transfer the energy because its Poynting vector is zero; in contrast, if the load is resistive, energy can then be conveyed from the transmitting coil to the receiving coil. The simulation results for the magnetic field distributions and the time-domain current waveforms agree very well with the results of the theoretical analysis. This work thus provides a comprehensive understanding of the energy transfer mechanism involved in the magnetic resonant coupling system.

  5. Topology of magnetic flux ropes and formation of fossil flux transfer events and boundary layer plasmas

    Science.gov (United States)

    Lee, L. C.; Ma, Z. W.; Fu, Z. F.; Otto, A.

    1993-01-01

    A mechanism for the formation of fossil flux transfer events and the low-level boundary layer within the framework of multiple X-line reconnection is proposed. Attention is given to conditions for which the bulk of magnetic flux in a flux rope of finite extent has a simple magnetic topology, where the four possible connections of magnetic field lines are: IMF to MSP, MSP to IMF, IMF to IMF, and MSP to MSP. For a sufficient relative shift of the X lines, magnetic flux may enter a flux rope from the magnetosphere and exit into the magnetosphere. This process leads to the formation of magnetic flux ropes which contain a considerable amount of magnetosheath plasma on closed magnetospheric field lines. This process is discussed as a possible explanation for the formation of fossil flux transfer events in the magnetosphere and the formation of the low-latitude boundary layer.

  6. Optimal Magnetic Field Shielding Method by Metallic Sheets in Wireless Power Transfer System

    Directory of Open Access Journals (Sweden)

    Feng Wen

    2016-09-01

    Full Text Available To meet the regulations established to limit human exposure to time-varying electromagnetic fields (EMFs such as the International Committee on Non-Ionizing Radiation Protection (ICNIRP guidelines, thin metallic sheets are often used to shield magnetic field leakage in high power applications of wireless power transfer (WPT systems based on magnetic field coupling. However, the metals in the vicinity of the WPT coils cause the decrease of self and mutual inductances and increase of effective series resistance; as such, the electric performance including transmission power and the efficiency of the system is affected. With the research objective of further investigating excellent shielding effectiveness associated with system performance, the utilization of the optimal magnetic field shielding method by metallic sheets in magnetic field coupling WPT is carried out in this paper. The circuit and 3D Finite Element Analysis (FEA models are combined to predict the magnetic field distribution and electrical performance. Simulation and experiment results show that the method is very effective by obtaining the largest possible coupling coefficient of the WPT coils within the allowable range and then reducing the value nearest to and no smaller than the critical coupling coefficient via geometric unbroken metallic sheets. The optimal magnetic field shielding method which considers the system efficiency, transmission power, transmission distance, and system size is also achieved using the analytic hierarchy process (AHP. The results can benefit WPT by helping to achieve efficient energy transfer and safe use in metal shielded equipment.

  7. A Wireless Magnetic Resonance Energy Transfer System for Micro Implantable Medical Sensors

    Directory of Open Access Journals (Sweden)

    Tianyang Yang

    2012-07-01

    Full Text Available Based on the magnetic resonance coupling principle, in this paper a wireless energy transfer system is designed and implemented for the power supply of micro-implantable medical sensors. The entire system is composed of the in vitro part, including the energy transmitting circuit and resonant transmitter coils, and in vivo part, including the micro resonant receiver coils and signal shaping chip which includes the rectifier module and LDO voltage regulator module. Transmitter and receiver coils are wound by Litz wire, and the diameter of the receiver coils is just 1.9 cm. The energy transfer efficiency of the four-coil system is greatly improved compared to the conventional two-coil system. When the distance between the transmitter coils and the receiver coils is 1.5 cm, the transfer efficiency is 85% at the frequency of 742 kHz. The power transfer efficiency can be optimized by adding magnetic enhanced resonators. The receiving voltage signal is converted to a stable output voltage of 3.3 V and a current of 10 mA at the distance of 2 cm. In addition, the output current varies with changes in the distance. The whole implanted part is packaged with PDMS of excellent biocompatibility and the volume of it is about 1 cm3.

  8. Molecular, dynamic, and structural origin of inhomogeneous magnetization transfer in lipid membranes.

    Science.gov (United States)

    Swanson, Scott D; Malyarenko, Dariya I; Fabiilli, Mario L; Welsh, Robert C; Nielsen, Jon-Fredrik; Srinivasan, Ashok

    2017-03-01

    To elucidate the dynamic, structural, and molecular properties that create inhomogeneous magnetization transfer (ihMT) contrast. Amphiphilic lipids, lamellar phospholipids with cholesterol, and bovine spinal cord (BSC) specimens were examined along with nonlipid systems. Magnetization transfer (MT), enhanced MT (eMT, obtained with double-sided radiofrequency saturation), ihMT (MT - eMT), and dipolar relaxation, T 1D , were measured at 2.0 and 11.7 T. The amplitude of ihMT ratio (ihMTR) is positively correlated with T 1D values. Both ihMTR and T 1D increase with increasing temperature in BSC white matter and in phospholipids and decrease with temperature in other lipids. Changes in ihMTR with temperature arise primarily from alterations in MT rather than eMT. Spectral width of MT, eMT, and ihMT increases with increasing carbon chain length. Concerted motions of phospholipids in white matter decrease proton spin diffusion leading to increased proton T 1D times and increased ihMT amplitudes, consistent with decoupling of Zeeman and dipolar spin reservoirs. Molecular specificity and dynamic sensitivity of ihMT contrast make it a suitable candidate for probing myelin membrane disorders. Magn Reson Med 77:1318-1328, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Quantitative Magnetization Transfer in Monitoring Glioblastoma (GBM) Response to Therapy.

    Science.gov (United States)

    Mehrabian, Hatef; Myrehaug, Sten; Soliman, Hany; Sahgal, Arjun; Stanisz, Greg J

    2018-02-06

    Quantitative magnetization transfer (qMT) was used as a biomarker to monitor glioblastoma (GBM) response to chemo-radiation and identify the earliest time-point qMT could differentiate progressors from non-progressors. Nineteen GBM patients were recruited and MRI-scanned before (Day 0 ), two weeks (Day 14 ), and four weeks (Day 28 ) into the treatment, and one month after the end of the treatment (Day 70 ). Comprehensive qMT data was acquired, and a two-pool MT model was fit to the data. Response was determined at 3-8 months following the end of chemo-radiation. The amount of magnetization transfer ([Formula: see text]) was significantly lower in GBM compared to normal appearing white matter (p GBM are more sensitive to treatment effects compared to clinically used metrics. qMT could assess tumor aggressiveness and identify early progressors even before the treatment. Changes in qMT parameters within the first 14 days of the treatment were capable of separating early progressors from non-progressors, making qMT a promising biomarker to guide adaptive radiotherapy for GBM.

  10. Magnetic error analysis of recycler pbar injection transfer line

    Energy Technology Data Exchange (ETDEWEB)

    Yang, M.J.; /Fermilab

    2007-06-01

    Detailed study of Fermilab Recycler Ring anti-proton injection line became feasible with its BPM system upgrade, though the beamline has been in existence and operational since year 2000. Previous attempts were not fruitful due to limitations in the BPM system. Among the objectives are the assessment of beamline optics and the presence of error fields. In particular the field region of the permanent Lambertson magnets at both ends of R22 transfer line will be scrutinized.

  11. Magnetic resonance imaging of flow and mass transfer in electrohydrodynamic liquid bridges

    NARCIS (Netherlands)

    Wexler, Adam D.; Drusová, Sandra; Fuchs, Elmar C.; Woisetschläger, Jakob; Reiter, Gert; Fuchsjäger, Michael; Reiter, Ursula

    2017-01-01

    Abstract: Here, we report on the feasibility and use of magnetic resonance imaging-based methods to the study of electrohydrodynamic (EHD) liquid bridges. High-speed tomographic recordings through the longitudinal axis of water bridges were used to characterize the mass transfer dynamics, mixing,

  12. Effects of magnetic fields on improving mass transfer in flue gas desulfurization using a fluidized bed

    Science.gov (United States)

    Zhang, Qi; Gui, Keting; Wang, Xiaobo

    2016-02-01

    The effects of magnetic fields on improving the mass transfer in flue gas desulfurization using a fluidized bed are investigated in the paper. In this research, the magnetically fluidized bed (MFB) is used as the reactor in which ferromagnetic particles are fluidized with simulated flue gas under the influence of an external magnetic field. Lime slurry is continuously sprayed into the reactor. As a consequence, the desulfurization reaction and the slurry drying process take place simultaneously in the MFB. In this paper, the effects of ferromagnetic particles and external magnetic fields on the desulphurization efficiency are studied and compared with that of quartz particles as the fluidized particles. Experimental results show that the ferromagnetic particles not only act as a platform for lime slurry to precipitate on like quartz particles, but also take part in the desulfurization reaction. The results also show that the specific surface area of ferromagnetic particles after reaction is enlarged as the magnetic intensity increases, and the external magnetic field promotes the oxidation of S(IV), improving the mass transfer between sulphur and its sorbent. Hence, the efficiency of desulphurization under the effects of external magnetic fields is higher than that in general fluidized beds.

  13. Angular dependence of spin transfer torque on magnetic tunnel junctions with synthetic ferrimagnetic free layer

    International Nuclear Information System (INIS)

    Ichimura, M; Hamada, T; Imamura, H; Takahashi, S; Maekawa, S

    2010-01-01

    Based on a spin-polarized free-electron model, spin and charge transports are analyzed in magnetic tunnel junctions with synthetic ferrimagnetic layers in the ballistic regime, and the spin transfer torque is derived. We characterize the synthetic ferrimagnetic free layer by extending an arbitrary direction of magnetizations of the two free layers forming the synthetic ferrimagnetic free layer. The synthetic ferrimagnetic configuration exerts the approximately optimum torque for small magnetization angle of the first layer relative to that of the pinned layer. For approximately anti-parallel magnetization of the first layer to that of the pinned layer, the parallel magnetization of two magnetic layers is favorable for magnetization reversal rather than the synthetic ferrimagnetic configuration.

  14. Bimonthly assessment of magnetization transfer magnetic resonance imaging parameters in multiple sclerosis: a 14-month, multicentre, follow-up study

    NARCIS (Netherlands)

    Mesaros, S.; Rocca, M.A.; Sormani, M.P.; Valsasina, P.; Markowitz, C.; De Stefano, N.; Montalban, X.; Barkhof, F.; Ranjeva, J.P.; Sailer, M.; Kappos, L.; Comi, G.; Filippi, M.

    2010-01-01

    This study was performed to assess the temporal evolution of damage within lesions and the normal-appearing white matter, measured using frequent magnetization transfer (MT) MRI, in relapsing-remitting multiple sclerosis (RRMS). The relationship of MT ratio (MTR) changes with measures of lesion

  15. Investigating spin-transfer torques induced by thermal gradients in magnetic tunnel junctions by using micro-cavity ferromagnetic resonance

    Science.gov (United States)

    Cansever, H.; Narkowicz, R.; Lenz, K.; Fowley, C.; Ramasubramanian, L.; Yildirim, O.; Niesen, A.; Huebner, T.; Reiss, G.; Lindner, J.; Fassbender, J.; Deac, A. M.

    2018-06-01

    Similar to electrical currents flowing through magnetic multilayers, thermal gradients applied across the barrier of a magnetic tunnel junction may induce pure spin-currents and generate ‘thermal’ spin-transfer torques large enough to induce magnetization dynamics in the free layer. In this study, we describe a novel experimental approach to observe spin-transfer torques induced by thermal gradients in magnetic multilayers by studying their ferromagnetic resonance response in microwave cavities. Utilizing this approach allows for measuring the magnetization dynamics on micron/nano-sized samples in open-circuit conditions, i.e. without the need of electrical contacts. We performed first experiments on magnetic tunnel junctions patterned into 6  ×  9 µm2 ellipses from Co2FeAl/MgO/CoFeB stacks. We conducted microresonator ferromagnetic resonance (FMR) under focused laser illumination to induce thermal gradients in the layer stack and compared them to measurements in which the sample was globally heated from the backside of the substrate. Moreover, we carried out broadband FMR measurements under global heating conditions on the same extended films the microstructures were later on prepared from. The results clearly demonstrate the effect of thermal spin-torque on the FMR response and thus show that the microresonator approach is well suited to investigate thermal spin-transfer-driven processes for small temperatures gradients, far below the gradients required for magnetic switching.

  16. Analisa Compact Wireless Power Transfer (CWPT menggunakan Metode Magnetic Resonator Coupling

    Directory of Open Access Journals (Sweden)

    Bambang Sudibya

    2016-12-01

    Full Text Available Magnetic Resonator Coupling banyak dipergunakan untuk berbagai aplikasi Wireless Power Transfer (WPT. Pada penelitian ini berhasil dirancang WPT dengan tegangan sebesar 5 V. Jika Tx dan Rx diposisikan saling berhadapan, tegangan maksimum 4,7 volt pada jarak 1 cm. Sementara itu, jika Tx dan Rx diposisikan berdampingan, tegangan yang dihasilkan dari 3.5V.

  17. Materials and Physics Challenges for Spin Transfer Torque Magnetic Random Access Memories

    Energy Technology Data Exchange (ETDEWEB)

    Heinonen, O.

    2014-10-05

    Magnetic random access memories utilizing the spin transfer torque effect for writing information are a strong contender for non-volatile memories scalable to the 20 nm node, and perhaps beyond. I will here examine how these devices behave as the device size is scaled down from 70 nm size to 20 nm. As device sizes go below ~50 nm, the size becomes comparable to intrinsic magnetic length scales and the device behavior does not simply scale with size. This has implications for the device design and puts additional constraints on the materials in the device.

  18. Comptonization in Ultra-Strong Magnetic Fields: Numerical Solution to the Radiative Transfer Problem

    Science.gov (United States)

    Ceccobello, C.; Farinelli, R.; Titarchuk, L.

    2014-01-01

    We consider the radiative transfer problem in a plane-parallel slab of thermal electrons in the presence of an ultra-strong magnetic field (B approximately greater than B(sub c) approx. = 4.4 x 10(exp 13) G). Under these conditions, the magnetic field behaves like a birefringent medium for the propagating photons, and the electromagnetic radiation is split into two polarization modes, ordinary and extraordinary, that have different cross-sections. When the optical depth of the slab is large, the ordinary-mode photons are strongly Comptonized and the photon field is dominated by an isotropic component. Aims. The radiative transfer problem in strong magnetic fields presents many mathematical issues and analytical or numerical solutions can be obtained only under some given approximations. We investigate this problem both from the analytical and numerical point of view, provide a test of the previous analytical estimates, and extend these results with numerical techniques. Methods. We consider here the case of low temperature black-body photons propagating in a sub-relativistic temperature plasma, which allows us to deal with a semi-Fokker-Planck approximation of the radiative transfer equation. The problem can then be treated with the variable separation method, and we use a numerical technique to find solutions to the eigenvalue problem in the case of a singular kernel of the space operator. The singularity of the space kernel is the result of the strong angular dependence of the electron cross-section in the presence of a strong magnetic field. Results. We provide the numerical solution obtained for eigenvalues and eigenfunctions of the space operator, and the emerging Comptonization spectrum of the ordinary-mode photons for any eigenvalue of the space equation and for energies significantly lesser than the cyclotron energy, which is on the order of MeV for the intensity of the magnetic field here considered. Conclusions. We derived the specific intensity of the

  19. Heat and Mass Transfer on Squeezing Unsteady MHD Nano fluid Flow between Parallel Plates with Slip Velocity Effect

    International Nuclear Information System (INIS)

    Singh, K.; Rawat, S. K.; Kumar, M.

    2016-01-01

    Heat and mass transfer behavior of unsteady flow of squeezing between two parallel plates in the sight of uniform magnetic field with slip velocity effect is investigated. The governing equations representing fluid flow have been transformed into nonlinear ordinary differential equations using similarity transformation. The equations thus obtained have been solved numerically using Runge-Kutta-Fehlberg method with shooting technique. Effects on the behavior of velocity, temperature, and concentration for various values of relevant parameters are illustrated graphically. The skin-friction coefficient and heat and mass transfer rate are also tabulated for various governing parameters. The results indicate that, for nano fluid flow, the rates of heat and mass transfer are inversely proportional to nanoparticle volume fraction and magnetic parameter. The rate of mass transfer increases with increasing values of Schmidt number and squeeze number.

  20. Alignment Compensation for Bending Radius in TT40 and TI 8 Transfer Line Magnets

    CERN Document Server

    Weterings, W

    2003-01-01

    The BEATCH file for the TI 8 transfer lines specifies the position of the bending magnets assuming that the beam enters and exits at the centre of the vacuum pipe. In order to distribute the deflected beam evenly inside the vacuum tube, the alignment has to be compensated by moving the magnets half of the beam deflection away from the centre of the bending radius. In this note the saggitas of the various TT40 and TI 8 magnets are calculated and the alignment displacements tabulated for future reference.

  1. Unsteady Magnetized Flow and Heat Transfer of a Viscoelastic fluid over a Stretching Surface

    Science.gov (United States)

    Ghosh, Sushil Kumar

    2017-12-01

    This paper is to study the flow of heated ferro-fluid over a stretching sheet under the influence of magnetic field. The fluid considered in the present investigation is a mixture of blood as well as fluid-dispersed magnetic nano particles and under this context blood is found to be the appropriate choice of viscoelastic, Walter's B fluid. The objective of the present work is to study the effect of various parameters found in the mathematical analysis. Taking into account the blood has zero electrical conductivity, magnetization effect has been considered in the governing equation of the present study with the use of ferro-fluid dynamics principle. By introducing appropriate non-dimensional variables into the governing equations of unsteady two-dimensional flow of viscoelastic fluid with heat transfer are converted to a set of ordinary differential equations with appropriate boundary conditions. Newton's linearization technique has been employed for the solution of non-linear ordinary differential equations. Important results found in the present investigation are the substantial influence of ferro-magnetic parameter, Prandlt number and the parameter associated with the thermal conductivity on the flow and heat transfer. It is observed that the presence of magnetic dipole essentially reduces the flow velocity in the vertical direction and that helps to damage the cancer cells in the tumor region.

  2. Magnetization transfer and spin lock MR imaging of patellar cartilage degeneration at 0.1 T

    International Nuclear Information System (INIS)

    Koskinen, S.K.; Ylae-Outinen, H.; Komu, M.E.S.; Aho, H.J.

    1997-01-01

    Purpose: To investigate magnetization transfer (MT) parameters and rotating frame relaxation time T1ρ in patellar cartilage at different levels of degeneration. Material and Methods: Thirty cadaveric patellae were examined at 0.1 T using the time-dependent saturation-transfer MT technique and the spin lock (SL) technique. In an SL experiment, nuclear spins are locked with a radiofrequency (RF) field, and the locked nuclear magnetization relaxes along the magnetic component of the locking RF field. The specimens were divided into three groups according to the level of cartilage degeneration. MT parameters and T1ρ were measured. Results: The MT effect was greater in degenerated cartilage than in normal cartilage. T1ρ was longer in advanced cartilage degeneration than in intermediate cartilage degeneration. Conculsion: The results suggest that more studies are needed to fully establish the value of SL imaging in cartilage degeneration. (orig.)

  3. An optimized framework for quantitative magnetization transfer imaging of the cervical spinal cord in vivo.

    Science.gov (United States)

    Battiston, Marco; Grussu, Francesco; Ianus, Andrada; Schneider, Torben; Prados, Ferran; Fairney, James; Ourselin, Sebastien; Alexander, Daniel C; Cercignani, Mara; Gandini Wheeler-Kingshott, Claudia A M; Samson, Rebecca S

    2018-05-01

    To develop a framework to fully characterize quantitative magnetization transfer indices in the human cervical cord in vivo within a clinically feasible time. A dedicated spinal cord imaging protocol for quantitative magnetization transfer was developed using a reduced field-of-view approach with echo planar imaging (EPI) readout. Sequence parameters were optimized based in the Cramer-Rao-lower bound. Quantitative model parameters (i.e., bound pool fraction, free and bound pool transverse relaxation times [ T2F, T2B], and forward exchange rate [k FB ]) were estimated implementing a numerical model capable of dealing with the novelties of the sequence adopted. The framework was tested on five healthy subjects. Cramer-Rao-lower bound minimization produces optimal sampling schemes without requiring the establishment of a steady-state MT effect. The proposed framework allows quantitative voxel-wise estimation of model parameters at the resolution typically used for spinal cord imaging (i.e. 0.75 × 0.75 × 5 mm 3 ), with a protocol duration of ∼35 min. Quantitative magnetization transfer parametric maps agree with literature values. Whole-cord mean values are: bound pool fraction = 0.11(±0.01), T2F = 46.5(±1.6) ms, T2B = 11.0(±0.2) µs, and k FB  = 1.95(±0.06) Hz. Protocol optimization has a beneficial effect on reproducibility, especially for T2B and k FB . The framework developed enables robust characterization of spinal cord microstructure in vivo using qMT. Magn Reson Med 79:2576-2588, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc

  4. Heat and momentum transfer for magnetoconvection in a vertical external magnetic field

    Science.gov (United States)

    Zürner, Till; Liu, Wenjun; Krasnov, Dmitry; Schumacher, Jörg

    2016-11-01

    The scaling theory of Grossmann and Lohse for the turbulent heat and momentum transfer is extended to the magnetoconvection case in the presence of a (strong) vertical magnetic field. The comparison with existing laboratory experiments and direct numerical simulations in the quasistatic limit allows to restrict the parameter space to very low Prandtl and magnetic Prandtl numbers and thus to reduce the number of unknown parameters in the model. Also included is the Chandrasekhar limit for which the outer magnetic induction field B is large enough such that convective motion is suppressed and heat is transported by diffusion. Our theory identifies four distinct regimes of magnetoconvection which are distinguished by the strength of the outer magnetic field and the level of turbulence in the flow, respectively. LIMTECH Research Alliance and Research Training Group GK 1567 on Lorentz Force Velocimetry, funded by the Deutsche Forschungsgemeinschaft.

  5. Falkner-Skan Flow of a Maxwell Fluid with Heat Transfer and Magnetic Field

    Directory of Open Access Journals (Sweden)

    M. Qasim

    2013-01-01

    Full Text Available This investigation deals with the Falkner-Skan flow of a Maxwell fluid in the presence of nonuniform applied magnetic fi…eld with heat transfer. Governing problems of flow and heat transfer are solved analytically by employing the homotopy analysis method (HAM. Effects of the involved parameters, namely, the Deborah number, Hartman number, and the Prandtl number, are examined carefully. A comparative study is made with the known numerical solution in a limiting sense and an excellent agreement is noted.

  6. India's Conditional Cash Transfer Programme (the JSY to Promote Institutional Birth: Is There an Association between Institutional Birth Proportion and Maternal Mortality?

    Directory of Open Access Journals (Sweden)

    Bharat Randive

    Full Text Available India accounts for 19% of global maternal deaths, three-quarters of which come from nine states. In 2005, India launched a conditional cash transfer (CCT programme, Janani Suraksha Yojana (JSY, to reduce maternal mortality ratio (MMR through promotion of institutional births. JSY is the largest CCT in the world. In the nine states with relatively lower socioeconomic levels, JSY provides a cash incentive to all women on birthing in health institution. The cash incentive is intended to reduce financial barriers to accessing institutional care for delivery. Increased institutional births are expected to reduce MMR. Thus, JSY is expected to (a increase institutional births and (b reduce MMR in states with high proportions of institutional births. We examine the association between (a service uptake, i.e., institutional birth proportions and (b health outcome, i.e., MMR.Data from Sample Registration Survey of India were analysed to describe trends in proportion of institutional births before (2005 and during (2006-2010 the implementation of the JSY. Data from Annual Health Survey (2010-2011 for all 284 districts in above- mentioned nine states were analysed to assess relationship between MMR and institutional births.Proportion of institutional births increased from a pre-programme average of 20% to 49% in 5 years (p<0.05. In bivariate analysis, proportion of institutional births had a small negative correlation with district MMR (r = -0.11.The multivariate regression model did not establish significant association between institutional birth proportions and MMR [CI: -0.10, 0.68].Our analysis confirmed that JSY succeeded in raising institutional births significantly. However, we were unable to detect a significant association between institutional birth proportion and MMR. This indicates that high institutional birth proportions that JSY has achieved are of themselves inadequate to reduce MMR. Other factors including improved quality of care at

  7. Energy Transfer and Dual Cascade in Kinetic Magnetized Plasma Turbulence

    International Nuclear Information System (INIS)

    Plunk, G. G.; Tatsuno, T.

    2011-01-01

    The question of how nonlinear interactions redistribute the energy of fluctuations across available degrees of freedom is of fundamental importance in the study of turbulence and transport in magnetized weakly collisional plasmas, ranging from space settings to fusion devices. In this Letter, we present a theory for the dual cascade found in such plasmas, which predicts a range of new behavior that distinguishes this cascade from that of neutral fluid turbulence. These phenomena are explained in terms of the constrained nature of spectral transfer in nonlinear gyrokinetics. Accompanying this theory are the first observations of these phenomena, obtained via direct numerical simulations using the gyrokinetic code AstroGK. The basic mechanisms that are found provide a framework for understanding the turbulent energy transfer that couples scales both locally and nonlocally.

  8. Energy Transfer and Dual Cascade in Kinetic Magnetized Plasma Turbulence

    Science.gov (United States)

    Plunk, G. G.; Tatsuno, T.

    2011-04-01

    The question of how nonlinear interactions redistribute the energy of fluctuations across available degrees of freedom is of fundamental importance in the study of turbulence and transport in magnetized weakly collisional plasmas, ranging from space settings to fusion devices. In this Letter, we present a theory for the dual cascade found in such plasmas, which predicts a range of new behavior that distinguishes this cascade from that of neutral fluid turbulence. These phenomena are explained in terms of the constrained nature of spectral transfer in nonlinear gyrokinetics. Accompanying this theory are the first observations of these phenomena, obtained via direct numerical simulations using the gyrokinetic code AstroGK. The basic mechanisms that are found provide a framework for understanding the turbulent energy transfer that couples scales both locally and nonlocally.

  9. Analysis of thermally induced magnetization dynamics in spin-transfer nano-oscillators

    Energy Technology Data Exchange (ETDEWEB)

    D' Aquino, M., E-mail: daquino@uniparthenope.it [Department of Technology, University of Naples ' Parthenope' , 80143 Naples (Italy); Serpico, C. [Department of Engineering, University of Naples Federico II, 80125 Naples (Italy); Bertotti, G. [Istituto Nazionale di Ricerca Metrologica 10135 Torino (Italy); Bonin, R. [Politecnico di Torino - Sede di Verres, 11029 Verres (Aosta) (Italy); Mayergoyz, I.D. [ECE Department and UMIACS, University of Maryland, College Park, MD 20742 (United States)

    2012-05-01

    The thermally induced magnetization dynamics in the presence of spin-polarized currents injected into a spin-valve-like structure used as microwave spin-transfer nano-oscillator (STNO) is considered. Magnetization dynamics is described by the stochastic Landau-Lifshitz-Slonczewski (LLS) equation. First, it is shown that, in the presence of thermal fluctuations, the spectrum of the output signal of the STNO exhibits multiple peaks at low and high frequencies. This circumstance is associated with the occurrence of thermally induced transitions between stationary states and magnetization self-oscillations. Then, a theoretical approach based on the separation of time-scales is developed to obtain a stochastic dynamics only in the slow state variable, namely the energy. The stationary distribution of the energy and the aforementioned transition rates are analytically computed and compared with the results of direct integration of the LLS dynamics, showing very good agreement.

  10. Pulse electromagnetic fields enhance extracellular electron transfer in magnetic bioelectrochemical systems.

    Science.gov (United States)

    Zhou, Huihui; Liu, Bingfeng; Wang, Qisong; Sun, Jianmin; Xie, Guojun; Ren, Nanqi; Ren, Zhiyong Jason; Xing, Defeng

    2017-01-01

    Microbial extracellular electron transfer (EET) is essential in driving the microbial interspecies interaction and redox reactions in bioelectrochemical systems (BESs). Magnetite (Fe 3 O 4 ) and magnetic fields (MFs) were recently reported to promote microbial EET, but the mechanisms of MFs stimulation of EET and current generation in BESs are not known. This study investigates the behavior of current generation and EET in a state-of-the-art pulse electromagnetic field (PEMF)-assisted magnetic BES (PEMF-MBES), which was equipped with magnetic carbon particle (Fe 3 O 4 @N-mC)-coated electrodes. Illumina Miseq sequencing of 16S rRNA gene amplicons was also conducted to reveal the changes of microbial communities and interactions on the anode in response to magnetic field. PEMF had significant influences on current generation. When reactors were operated in microbial fuel cell (MFC) mode with pulse electromagnetic field (PEMF-MMFCs), power densities increased by 25.3-36.0% compared with no PEMF control MFCs (PEMF-OFF-MMFCs). More interestingly, when PEMF was removed, the power density dropped by 25.7%, while when PEMF was reintroduced, the value was restored to the previous level. Illumina sequencing of 16S rRNA gene amplicon and principal component analysis (PCA) based on operational taxonomic units (OTUs) indicate that PEMFs led to the shifts in microbial community and changes in species evenness that decreased biofilm microbial diversity. Geobacter spp. were found dominant in all anode biofilms, but the relative abundance in PEMF-MMFCs (86.1-90.0%) was higher than in PEMF-OFF-MMFCs (82.5-82.7%), indicating that the magnetic field enriched Geobacter on the anode. The current generation of Geobacter -inoculated microbial electrolysis cells (MECs) presented the same change regularity, the accordingly increase or decrease corresponding with switch of PEMF, which confirmed the reversible stimulation of PEMFs on microbial electron transfer. The pulse electromagnetic

  11. Magnetic field effect on nanoparticles migration and heat transfer of water/alumina nanofluid in a channel

    Energy Technology Data Exchange (ETDEWEB)

    Malvandi, A., E-mail: amirmalvandi@aut.ac.ir [Department of Mechanical Engineering, Amirkabir University of Technology (Tehran Polytechnic), 424 Hafez Avenue, Tehran (Iran, Islamic Republic of); Ganji, D.D., E-mail: ddg_davood@yahoo.com [Mechanical Engineering Department, Babol Noshirvani University of Technology, Babol (Iran, Islamic Republic of)

    2014-08-01

    The present study is a theoretical investigation of the laminar flow and convective heat transfer of water/alumina nanofluid inside a parallel-plate channel in the presence of a uniform magnetic field. A modified two-component, four-equation, nonhomogeneous equilibrium model was employed for the alumina/water nanofluid, which fully accounted for the effect of the nanoparticle volume fraction distribution. The no-slip condition of the fluid–solid interface is abandoned in favor of a slip condition which appropriately represents the non-equilibrium region near the interface at micro/nano channels. The results obtained indicated that nanoparticles move from the heated walls (nanoparticles depletion) toward the core region of the channel (nanoparticles accumulation) and construct a non-uniform nanoparticles distribution. Moreover, in the presence of the magnetic field, the near wall velocity gradients increase, enhancing the slip velocity and thus the heat transfer rate and pressure drop increase. - Highlights: • Force convection of alumina/water nanofluid inside a parallel-plate channel. • Magnetic field effects on nanoparticles' migration. • Effects of Brownian motion and thermophoresis diffusivities on nanoparticle migration. • Different mechanisms of heat transfer rate based on nanoparticles' diameter.

  12. Numerical investigation of the heat transfer of a ferrofluid inside a tube in the presence of a non-uniform magnetic field

    Science.gov (United States)

    Hariri, Saman; Mokhtari, Mojtaba; Gerdroodbary, M. Barzegar; Fallah, Keivan

    2017-02-01

    In this article, a three-dimensional numerical investigation is performed to study the effect of a magnetic field on a ferrofluid inside a tube. This study comprehensively analyzes the influence of a non-uniform magnetic field in the heat transfer of a tube while a ferrofluid (water with 0.86 vol% nanoparticles (Fe3O4) is let flow. The SIMPLEC algorithm is used for obtaining the flow and heat transfer inside the tube. The influence of various parameters, such as concentration of nanoparticles, intensity of the magnetic field, wire distance and Reynolds number, on the heat transfer is investigated. According to the obtained results, the presence of a non-uniform magnetic field significantly increases the Nusselt number (more than 300%) inside the tube. Also, the magnetic field induced by the parallel wire affects the average velocity of the ferrofluid and forms two strong eddies in the tube. Our findings show that the diffusion also raises as the concentration of the nanoparticle is increased.

  13. Experimental investigation of MHD heat transfer in a vertical round tube affected by transverse magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Melnikov, I.A., E-mail: corpuskula@gmail.com; Sviridov, E.V.; Sviridov, V.G.; Razuvanov, N.G.

    2016-11-15

    Highlights: • Local and averaged heat transfer coefficient are measured. • Free convection influence on MHD-flow is investigated. • The region with the free convection effect of MHD-heat transfer is found. • Temperature low-frequency fluctuations of abnormally high amplitude are detected. • Analysis of the MHD-heat transfer experimental data is performed. - Abstract: The article is devoted to the results of experimental investigation of heat transfer for a downward mercury flow in a vertical round tube in the presence of a transverse magnetic with non-uniform heat flux along the tube circumference.

  14. Magnetic forces and localized resonances in electron transfer through quantum rings.

    Science.gov (United States)

    Poniedziałek, M R; Szafran, B

    2010-11-24

    We study the current flow through semiconductor quantum rings. In high magnetic fields the current is usually injected into the arm of the ring preferred by classical magnetic forces. However, for narrow magnetic field intervals that appear periodically on the magnetic field scale the current is injected into the other arm of the ring. We indicate that the appearance of the anomalous-non-classical-current circulation results from Fano interference involving localized resonant states. The identification of the Fano interference is based on the comparison of the solution of the scattering problem with the results of the stabilization method. The latter employs the bound-state type calculations and allows us to extract both the energy of metastable states localized within the ring and the width of resonances by analysis of the energy spectrum of a finite size system as a function of its length. The Fano resonances involving states of anomalous current circulation become extremely narrow on both the magnetic field and energy scales. This is consistent with the orientation of the Lorentz force that tends to keep the electron within the ring and thus increases the lifetime of the electron localization within the ring. Absence of periodic Fano resonances in electron transfer probability through a quantum ring containing an elastic scatterer is also explained.

  15. India's Conditional Cash Transfer Programme (the JSY) to Promote Institutional Birth: Is There an Association between Institutional Birth Proportion and Maternal Mortality?

    Science.gov (United States)

    Randive, Bharat; Diwan, Vishal; De Costa, Ayesha

    2013-01-01

    India accounts for 19% of global maternal deaths, three-quarters of which come from nine states. In 2005, India launched a conditional cash transfer (CCT) programme, Janani Suraksha Yojana (JSY), to reduce maternal mortality ratio (MMR) through promotion of institutional births. JSY is the largest CCT in the world. In the nine states with relatively lower socioeconomic levels, JSY provides a cash incentive to all women on birthing in health institution. The cash incentive is intended to reduce financial barriers to accessing institutional care for delivery. Increased institutional births are expected to reduce MMR. Thus, JSY is expected to (a) increase institutional births and (b) reduce MMR in states with high proportions of institutional births. We examine the association between (a) service uptake, i.e., institutional birth proportions and (b) health outcome, i.e., MMR. Data from Sample Registration Survey of India were analysed to describe trends in proportion of institutional births before (2005) and during (2006-2010) the implementation of the JSY. Data from Annual Health Survey (2010-2011) for all 284 districts in above- mentioned nine states were analysed to assess relationship between MMR and institutional births. Proportion of institutional births increased from a pre-programme average of 20% to 49% in 5 years (phigh institutional birth proportions that JSY has achieved are of themselves inadequate to reduce MMR. Other factors including improved quality of care at institutions are required for intended effect.

  16. Study of stream wise transverse magnetic fluid flow with heat transfer around an obstacle embedded in a porous medium

    Energy Technology Data Exchange (ETDEWEB)

    Rashidi, S. [Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad 91775-1111 (Iran, Islamic Republic of); Dehghan, M. [Department of Mechanical Engineering, Semnan University, P.O. Box: 35196-45399, Semnan (Iran, Islamic Republic of); Ellahi, R., E-mail: rellahi@engr.ucr.edu [Department of Mathematics and Statistics, FBAS, IIUI, 44000 Islamabad (Pakistan); Department of Mechanical Engineering, Bourns Hall, University of California, Riverside, CA 92521 (United States); Riaz, M. [Department of QEC, National Defense University, E-9 Sector, 44000 Islamabad (Pakistan); Jamal-Abad, M.T. [Department of Mechanical Engineering, Semnan University, P.O. Box: 35196-45399, Semnan (Iran, Islamic Republic of)

    2015-03-15

    A mathematical model for two-dimensional fluid flow under the influence of stream wise transverse magnetic fields in laminar regime is simulated in this study. Heat transfer past a square diamond shaped porous obstacle is also taken into account. The attention is focused to investigate the effects of intensity and direction of magnetic field, Darcy and Reynolds numbers on the mechanism of convective heat transfer and flow structures. The Darcy–Brinkman–Forchheimer model along with the Maxwell equations is used. The nonlinear coupled equations using a finite volume approach (FVA) are solved numerically. The calculations are performed for different governing parameters such as Reynolds number, Nusselt number, Stuart number and Prandtl Number. The physical interpretation of velocity and isothermal contours is assigned through graphs. It is shown that the effects of a transverse magnetic field on flow behavior and heat transfer mechanism are more than that of the stream wise magnetic field. The configuration of streamlines and vorticity contours phenomena are also presented for porous diamond obstacle. Comparison of the numerical solutions with existing literature is also made. - Highlights: • This paper analyses two-dimensional fluid flow under the influence of stream wise transverse magnetic field. • Heat transfer past a square diamond shaped porous obstacle is taken into account. • The Darcy–Brinkman–Forchheimer model is used. • Finite volume approach is used to find numerical solutions. • The configuration of streamlines and vorticity contours phenomena are presented through graphs.

  17. Zero-field spin transfer oscillators based on magnetic tunnel junction having perpendicular polarizer and planar free layer

    Directory of Open Access Journals (Sweden)

    Bin Fang

    2016-12-01

    Full Text Available We experimentally studied spin-transfer-torque induced magnetization oscillations in an asymmetric MgO-based magnetic tunnel junction device consisting of an in-plane magnetized free layer and an out-of-plane magnetized polarizer. A steady auto-oscillation was achieved at zero magnetic field and room temperature, with an oscillation frequency that was strongly dependent on bias currents, with a large frequency tunability of 1.39 GHz/mA. Our results suggest that this new structure has a high potential for new microwave device designs.

  18. Electro-mechanical energy conversion system having a permanent magnet machine with stator, resonant transfer link and energy converter controls

    Science.gov (United States)

    Skeist, S. Merrill; Baker, Richard H.

    2006-01-10

    An electro-mechanical energy conversion system coupled between an energy source and an energy load comprising an energy converter device including a permanent magnet induction machine coupled between the energy source and the energy load to convert the energy from the energy source and to transfer the converted energy to the energy load and an energy transfer multiplexer to control the flow of power or energy through the permanent magnetic induction machine.

  19. Reduction of momentum transfer rates by parallel electric fields: A two-fluid demonstration

    International Nuclear Information System (INIS)

    Delamere, P.A.; Stenbaek-Nielsen, H.C.; Otto, A.

    2002-01-01

    Momentum transfer between an ionized gas cloud moving relative to an ambient magnetized plasma is a general problem in space plasma physics. Obvious examples include the Io-Jupiter interaction, comets, and coronal mass ejections. Active plasma experiments have demonstrated that momentum transfer rates associated with Alfven wave propagation are poorly understood. Barium injection experiments from the Combined Release and Radiation Effects Satellite (CRRES) have shown that dense ionized clouds are capable of ExB drifting over large distances perpendicular to the magnetic field. The CRRES 'skidding' distances were much larger than predicted by magnetohydrodynamic theory and it has been proposed that parallel electric fields were a key component in the skidding phenomenon. A two-fluid code was used to demonstrate the role of parallel electric fields in reducing momentum transfer between two distinct plasma populations. In this study, a dense plasma was initialized moving relative to an ambient plasma and perpendicular to B. Parallel electric fields were introduced via a friction term in the electron momentum equation and the collision frequency was scaled in proportion to the field-aligned current density. The simulation results showed that parallel electric fields decreased the decelerating magnetic tension force on the plasma cloud through a magnetic diffusion/reconnection process

  20. Anomalous Tunnel Magnetoresistance and Spin Transfer Torque in Magnetic Tunnel Junctions with Embedded Nanoparticles

    Science.gov (United States)

    Useinov, Arthur; Ye, Lin-Xiu; Useinov, Niazbeck; Wu, Te-Ho; Lai, Chih-Huang

    2015-01-01

    The tunnel magnetoresistance (TMR) in the magnetic tunnel junction (MTJ) with embedded nanoparticles (NPs) was calculated in range of the quantum-ballistic model. The simulation was performed for electron tunneling through the insulating layer with embedded magnetic and non-magnetic NPs within the approach of the double barrier subsystem connected in parallel to the single barrier one. This model can be applied for both MTJs with in-plane magnetization and perpendicular one. We also calculated the in-plane component of the spin transfer torque (STT) versus the applied voltage in MTJs with magnetic NPs and determined that its value can be much larger than in single barrier system (SBS) for the same tunneling thickness. The reported simulation reproduces experimental data of the TMR suppression and peak-like TMR anomalies at low voltages available in leterature. PMID:26681336

  1. Passive Shielding Effect on Space Profile of Magnetic Field Emissions for Wireless Power Transfer to Vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2015-01-01

    Magnetic fields emitted by wireless power transfer systems are of high importance with respect to human safety and health. Aluminum and ferrite are used in the system to reduce the fields and are termed as passive shielding. In this paper, the influence of these materials on the space profile has...... fields for wireless power transfer for vehicle applications....

  2. Augmenting effectiveness of control loops of a PMSG (permanent magnet synchronous generator) based wind energy conversion system by a virtually adaptive PI (proportional integral) controller

    International Nuclear Information System (INIS)

    Alizadeh, Mojtaba; Kojori, Shokrollah Shokri

    2015-01-01

    Offering substantial features, PMSG (permanent magnet synchronous generator) based WECS (wind energy conversion system) is definitely one of the most reliable and efficient ways of extracting electrical power from the wind. Like other WECSs, PMSG-based WECS (PMSG WECS) encompasses two main control loops, each equipped with PI (proportional integral) controller, to control speed and currents of the system. This work develops a virtually adaptive PI controller to enhance the performance of both main control loops of a PMSG WECS. A WNN (wavelet neural network) is proposed to be added to each closed control loop in series with PI controller. Due to having a cascade connection, the transfer function of the WNN, which is a pure gain in each time step, is multiplied by PI gains. Therefore, the value of transfer function of the WNN, and consequently, both parameters of PI controller can be changed in each time step by online training of the WNN, resulting in a virtually adaptive PI controller. The performance of the proposed controller in improving efficacy of both current and speed control loops is evaluated by simulation studies and is also compared to that of PI controller, WNNC (wavelet neural network controller), and QNNC (quantum neural network controller). - Highlights: • To propose a virtually adaptive PI controller to be used in a PMSG WECS. • Both parameters of PI controller can be changed in each time step. • The proposed controller can be used as both current or speed controller. • The plant data is not required for offline training of proposed current controller.

  3. A Critical Review of Wireless Power Transfer via Strongly Coupled Magnetic Resonances

    Directory of Open Access Journals (Sweden)

    Xuezhe Wei

    2014-07-01

    Full Text Available Strongly coupled magnetic resonance (SCMR, proposed by researchers at MIT in 2007, attracted the world’s attention by virtue of its mid-range, non-radiative and high-efficiency power transfer. In this paper, current developments and research progress in the SCMR area are presented. Advantages of SCMR are analyzed by comparing it with the other wireless power transfer (WPT technologies, and different analytic principles of SCMR are elaborated in depth and further compared. The hot research spots, including system architectures, frequency splitting phenomena, impedance matching and optimization designs are classified and elaborated. Finally, current research directions and development trends of SCMR are discussed.

  4. Modulation of the wall-heat transfer in turbulent thermomagnetic convection by magnetic field gradients

    NARCIS (Netherlands)

    Kenjeres, S.; Zinsmeester, R.; Pyrda, L.; Fornalik-Wajs, E.; Szmyd, J.

    2015-01-01

    We present combined experimental and numerical studies of the heat transfer of paramagnetic or diamagnetic fluid inside a differentially heated cubical enclosure subjected to the magnetic field gradients of different strength and orientation. In contrast to the previously reported studies in

  5. Enhanced robust fractional order proportional-plus-integral controller based on neural network for velocity control of permanent magnet synchronous motor.

    Science.gov (United States)

    Zhang, Bitao; Pi, YouGuo

    2013-07-01

    The traditional integer order proportional-integral-differential (IO-PID) controller is sensitive to the parameter variation or/and external load disturbance of permanent magnet synchronous motor (PMSM). And the fractional order proportional-integral-differential (FO-PID) control scheme based on robustness tuning method is proposed to enhance the robustness. But the robustness focuses on the open-loop gain variation of controlled plant. In this paper, an enhanced robust fractional order proportional-plus-integral (ERFOPI) controller based on neural network is proposed. The control law of the ERFOPI controller is acted on a fractional order implement function (FOIF) of tracking error but not tracking error directly, which, according to theory analysis, can enhance the robust performance of system. Tuning rules and approaches, based on phase margin, crossover frequency specification and robustness rejecting gain variation, are introduced to obtain the parameters of ERFOPI controller. And the neural network algorithm is used to adjust the parameter of FOIF. Simulation and experimental results show that the method proposed in this paper not only achieve favorable tracking performance, but also is robust with regard to external load disturbance and parameter variation. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  6. Evaluation of magnetization transfer ratio in ascites and pelvic cystic masses

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Susumu [Nippon Medical School, Inba, Chiba (Japan). Chiba-Hokuso Hospital; Kato, Tomoyasu; Yamashita, Takashi [and others

    1997-12-01

    To investigate the feasibility of magnetization transfer contrast (MTC) in characterization of pelvic cystic masses and ascites, in vitro studies were performed. Cystic fluids were taken from operative specimens of ten ovarian cystic masses (five mucinous cystadenomas, one cystadenocarcinoma, two serous cystadenocarcinomas, two clear cell carcinomas) and three non-ovarian pelvic cysts (one paraovarian cyst, one pseudomyxoma peritonei, one pelvic abscess). Samples of ascitic flied were drawn by peritoneal puncture in twenty patients (thirteen with peritonitis carcinomatosa, five with liver dysfunction, two with renal dysfunction). Total protein content in ascitic fluids was measured. Magnetization transfer ratio (MTR) was calculated by the signal intensities under the gradient echo sequence with and without the application of off-resonance pulses. The relative signal intensities (RSI) relative to water in T{sub 1} and T{sub 2} weighted images were obtained using spin echo sequence. There was no correlation between histological type of pelvic mass and MTR and RSI. Good correlation (R{sup 2}=0.761) was obtained between MTR and protein content in ascitic fluids, whereas no correlation was noted between RSI and protein content in ascitic fluids. These results suggest that MTC is not useful in the characterization of pelvic masses but is applicable in the differentiation between exudative ascites and transudative ascites. (author)

  7. Spin transfer torque with spin diffusion in magnetic tunnel junctions

    KAUST Repository

    Manchon, Aurelien

    2012-08-09

    Spin transport in magnetic tunnel junctions in the presence of spin diffusion is considered theoretically. Combining ballistic tunneling across the barrier and diffusive transport in the electrodes, we solve the spin dynamics equation in the metallic layers. We show that spin diffusion mixes the transverse spin current components and dramatically modifies the bias dependence of the effective spin transfer torque. This leads to a significant linear bias dependence of the out-of-plane torque, as well as a nonconventional thickness dependence of both spin torque components.

  8. Passive shielding effect on space profile of magnetic field emissions for wireless power transfer to vehicles

    International Nuclear Information System (INIS)

    Batra, T.; Schaltz, E.

    2015-01-01

    Magnetic fields emitted by wireless power transfer systems are of high importance with respect to human safety and health. Aluminum and ferrite are used in the system to reduce the fields and are termed as passive shielding. In this paper, the influence of these materials on the space profile has been investigated with the help of simulations on Comsol for the four possible geometries—no shielding, ferrite, aluminum, and full shielding. As the reflected impedance varies for the four geometries, the primary current is varied accordingly to maintain constant power transfer to the secondary side. Surrounding magnetic field plots in the vertical direction show that maxima's of the two coils for the no shielding geometry are centered at the respective coils and for the remaining three are displaced closer to each other. This closeness would lead to more effective addition of the two coil fields and an increase in the resultant field from space point of view. This closeness varies with distance in the horizontal direction and vertical gap between the coils and is explained in the paper. This paper provides a better understanding of effect of the passive shielding materials on the space nature of magnetic fields for wireless power transfer for vehicle applications

  9. Passive shielding effect on space profile of magnetic field emissions for wireless power transfer to vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Batra, T., E-mail: tba@et.aau.dk; Schaltz, E. [Department of Energy Technology, Aalborg University, Aalborg 9220 (Denmark)

    2015-05-07

    Magnetic fields emitted by wireless power transfer systems are of high importance with respect to human safety and health. Aluminum and ferrite are used in the system to reduce the fields and are termed as passive shielding. In this paper, the influence of these materials on the space profile has been investigated with the help of simulations on Comsol for the four possible geometries—no shielding, ferrite, aluminum, and full shielding. As the reflected impedance varies for the four geometries, the primary current is varied accordingly to maintain constant power transfer to the secondary side. Surrounding magnetic field plots in the vertical direction show that maxima's of the two coils for the no shielding geometry are centered at the respective coils and for the remaining three are displaced closer to each other. This closeness would lead to more effective addition of the two coil fields and an increase in the resultant field from space point of view. This closeness varies with distance in the horizontal direction and vertical gap between the coils and is explained in the paper. This paper provides a better understanding of effect of the passive shielding materials on the space nature of magnetic fields for wireless power transfer for vehicle applications.

  10. On Electromagnetic Modulation of Flow Instabilities, Mixing and Heat Transfer in Conducting and Magnetized Fluids

    Science.gov (United States)

    Kenjeres, S.

    2016-09-01

    In the present paper we give a concise review of some recent highlights of our research dealing with electromagnetic control of flow, mixing and heat transfer of electrically conductive or magnetized fluids. We apply a combination of state-of-art numerical (DNS and LES) and experimental (PIV and LIF) techniques to provide fundamental insights into the complex phenomena of interactions between imposed (or induced) electromagnetic fields and underlying fluid flow. Our analysis covers an extensive range of working fluids, i.e. weakly- and highly-electrically-conductive, as well as magnetized fluids. These interactions are defined through the presence of different types of body forces acting per volume of fluid. A fully closed system of governing equations containing an extended set of the Navier-Stokes and a simplified set of the Maxwell equations is presented. The four characteristic examples are selected: the electromagnetic control of self-sustained jet oscillations, the electromagnetic enhancement of heat transfer in thermal convection, the wake interactions behind magnetic obstacles and finally, the thermo-magnetic convection in differentially heated cubical enclosure. The comparative assessment between experimental and numerical results is presented. It is concluded that generally good agreement between simulations and experiments is obtained for all cases considered, proving the concept of electromagnetic modulation, which can be used in numerous technological applications.

  11. Magnetism of DyMn2 and HoMn2 - 57Fe and 119Sn Moessbauer studies

    International Nuclear Information System (INIS)

    Krop, K.; Haeufler, T.; Hilscher, G.; Steiner, W.

    1995-01-01

    Moessbauer spectra were measured for two Laves phase compounds DyMn 2 and HoMn 2 in which manganese was substituted to 0.5% with 57 Fe and to 0.2% with 119 Sn. At 4.2 K the 57 Fe and 119 Sn spectra of the Dy compound were unambiguously fitted each with two Zeeman patterns (with relative contributions to the spectra 3:1) corresponding to two different Mn sites - magnetic and nonmagnetic. Transferred hyperfine fields at 119 Sn were found to be proportional to the magnetic moment of Dy and its ferromagnetic component, corroborating the magnetic structure found in neutron diffraction (ND) experiment. The same procedure was carried on with the spectra measured for the Ho compound, but the above mentioned proportionality was not found. ((orig.))

  12. Self-consistent treatment of spin and magnetization dynamic effect in spin transfer switching

    International Nuclear Information System (INIS)

    Guo Jie; Tan, Seng Ghee; Jalil, Mansoor Bin Abdul; Koh, Dax Enshan; Han, Guchang; Meng, Hao

    2011-01-01

    The effect of itinerant spin moment (m) dynamic in spin transfer switching has been ignored in most previous theoretical studies of the magnetization (M) dynamics. Thus in this paper, we proposed a more refined micromagnetic model of spin transfer switching that takes into account in a self-consistent manner of the coupled m and M dynamics. The numerical results obtained from this model further shed insight on the switching profiles of m and M, both of which show particular sensitivity to parameters such as the anisotropy field, the spin torque field, and the initial deviation between m and M.

  13. CWRU multiwire proportional counter readout system

    International Nuclear Information System (INIS)

    Bevington, P.R.; Leskovec, R.A.

    1977-01-01

    An electronic system is described which translates pulses from individual wires of multiwire proportional counters into binary addresses indicating the location of the wires in the chambers. The system combines a fast (<100 ns) serial scan of an event buffer with parallel encoding to provide fast transfer of addresses (250 ns per hit). The buffer has provision for disabling the input less than 40 ns after detection of an event to suppress recording of multiple hits caused by individual events. The encoder can digitize the address of every hit encountered or just the first addresses of contiguous hits. The system includes a coincidence trigger for determining whether timing criteria have been satisfied between chambers and with external devices. Events which do not meet the coincidence criteria are typically reset within 400 ns. The addresses are transferred to a computer interface through CAMAC modules. Multiple buffering permits further data acquisition during CAMAC transfer cycles. (Auth.)

  14. SPICE modelling of magnetic tunnel junctions written by spin-transfer torque

    Energy Technology Data Exchange (ETDEWEB)

    Guo, W; Prenat, G; De Mestier, N; Baraduc, C; Dieny, B [SPINTEC, UMR(8191), INAC, CEA/CNRS/UJF, 17 Av. des Martyrs, 38054 Grenoble Cedex 9 (France); Javerliac, V; El Baraji, M, E-mail: guillaume.prenat@cea.f [CROCUS Technology, 5 Place Robert Schuman, 38025 Grenoble (France)

    2010-06-02

    Spintronics aims at extending the possibility of conventional electronics by using not only the charge of the electron but also its spin. The resulting spintronic devices, combining the front-end complementary metal oxide semiconductor technology of electronics with a magnetic back-end technology, employ magnetic tunnel junctions (MTJs) as core elements. With the intent of simulating a circuit without fabricating it first, a reliable MTJ electrical model which is applicable to the standard SPICE (Simulation Program with Integrated Circuit Emphasis) simulator is required. Since such a model was lacking so far, we present a MTJ SPICE model whose magnetic state is written by using the spin-transfer torque effect. This model has been developed in the C language and validated on the Cadence Virtuoso Platform with a Spectre simulator. Its operation is similar to that of the standard BSIM (Berkeley Short-channel IGFET Model) SPICE model of the MOS transistor and fully compatible with the SPICE electrical simulator. The simulation results obtained using this model have been found in good accord with those theoretical macrospin calculations and results.

  15. Natural convection and boiling heat transfer of a liquid metal in a magnetic field

    International Nuclear Information System (INIS)

    Seki, Masahiro; Kawamura, Hiroshi

    1983-02-01

    A liquid metal is often assumed as a coolant and a breeding material of a Tokamak fusion reactor. However, many problems on the thermo-hydraulics of a liquid metal in a magnetic field are still remained to be studied. In the present report, natural convection and boiling of a liquid metal in a strong magnetic field are studied to examine a fundamental feasibility of a fusion reactor cooled by a liquid metal. In the experimental study of the natural convection, the circulation of a liquid metal was found to be surpressed even by a magnetic field parallel to the gravity. A numerical study has confirmed the conclusion drawn by the experiment. In the study of boiling heat transfer, stable boiling of a liquid metal has been found also in a strong magnetic field. The burnout heat flux hardly affected by the magnetic field. These indicate a fundamental feasibility of the liquid-metal cooling for a Tokamak fusion reactor. (author)

  16. Effects of Anisotropic Thermal Conductivity and Lorentz Force on the Flow and Heat Transfer of a Ferro-Nanofluid in a Magnetic Field

    Directory of Open Access Journals (Sweden)

    Yubai Li

    2017-07-01

    Full Text Available In this paper, we study the effects of the Lorentz force and the induced anisotropic thermal conductivity due to a magnetic field on the flow and the heat transfer of a ferro-nanofluid. The ferro-nanofluid is modeled as a single-phase fluid, where the viscosity depends on the concentration of nanoparticles; the thermal conductivity shows anisotropy due to the presence of the nanoparticles and the external magnetic field. The anisotropic thermal conductivity tensor, which depends on the angle of the applied magnetic field, is suggested considering the principle of material frame indifference according to Continuum Mechanics. We study two benchmark problems: the heat conduction between two concentric cylinders as well as the unsteady flow and heat transfer in a rectangular channel with three heated inner cylinders. The governing equations are made dimensionless, and the flow and the heat transfer characteristics of the ferro-nanofluid with different angles of the magnetic field, Hartmann number, Reynolds number and nanoparticles concentration are investigated systematically. The results indicate that the temperature field is strongly influenced by the anisotropic behavior of the nanofluids. In addition, the magnetic field may enhance or deteriorate the heat transfer performance (i.e., the time-spatially averaged Nusselt number in the rectangular channel depending on the situations.

  17. Survey of studies on the flow and heat transfer of two-component, two-phase flow of liquid metal in magnetic field

    International Nuclear Information System (INIS)

    Kumamaru, Hiroshige

    1980-01-01

    Brief review of the studies on the flow and heat transfer of two-component, two-phase flow of liquid metal in magnetic field is presented. R.J. Thome measured the distribution of void rate, slip ratio and pressure loss for the two-phase flow of NaK-N 2 under vertical magnetic field. The void rate distribution became even and the slip ratio increased with the increasing magnetic field. The experimental results of pressure loss was compared with the calculation by an equation derived from the homogeneous flow model. R.G. Owen et al. made the analytical studies of the MHD friction loss of two phase flow. Michiyoshi et al. made experimental studies on the hydrodynamic local properties of Hg-Ar two-phase flow of slug region in a vertically ascending tube under magnetic field, and Kimi et al. also made studies on the heat transfer of Hg-Ar flow under magnetic field. Saito et al. measured the slip ratio and pressure loss of NaK-N 2 flow. As a whole, it can be said that the average void rate decreases, and its distribution becomes even under magnetic field. The slip ratio increases, and the friction loss factor becomes nearly one. It was hard to make clear the heat transfer characteristics. (Kato, T.)

  18. Pulsatile flow of blood and heat transfer with variable viscosity under magnetic and vibration environment

    International Nuclear Information System (INIS)

    Shit, G.C.; Majee, Sreeparna

    2015-01-01

    Unsteady flow of blood and heat transfer characteristics in the neighborhood of an overlapping constricted artery have been investigated in the presence of magnetic field and whole body vibration. The laminar flow of blood is taken to be incompressible and Newtonian fluid with variable viscosity depending upon temperature with an aim to provide resemblance to the real situation in the physiological system. The unsteady flow mechanism in the constricted artery is subjected to a pulsatile pressure gradient arising from systematic functioning of the heart and from the periodic body acceleration. The numerical computation has been performed using finite difference method by developing Crank–Nicolson scheme. The results show that the volumetric flow rate, skin-friction and the rate of heat transfer at the wall are significantly altered in the downstream of the constricted region. The axial velocity profile, temperature and flow rate increases with increase in temperature dependent viscosity, while the opposite trend is observed in the case of skin-friction and flow impedance. - Highlights: • We have investigated the pulsatile MHD flow of blood and heat transfer in arteries. • The influence of periodic body acceleration has been taken into account. • The temperature dependent viscosity of blood is considered. • The variable viscosity has an increasing effect on blood flow and heat transfer. • The overall temperature distribution enhances in the presence of magnetic field

  19. Pulsatile flow of blood and heat transfer with variable viscosity under magnetic and vibration environment

    Energy Technology Data Exchange (ETDEWEB)

    Shit, G.C., E-mail: gopal_iitkgp@yahoo.co.in; Majee, Sreeparna

    2015-08-15

    Unsteady flow of blood and heat transfer characteristics in the neighborhood of an overlapping constricted artery have been investigated in the presence of magnetic field and whole body vibration. The laminar flow of blood is taken to be incompressible and Newtonian fluid with variable viscosity depending upon temperature with an aim to provide resemblance to the real situation in the physiological system. The unsteady flow mechanism in the constricted artery is subjected to a pulsatile pressure gradient arising from systematic functioning of the heart and from the periodic body acceleration. The numerical computation has been performed using finite difference method by developing Crank–Nicolson scheme. The results show that the volumetric flow rate, skin-friction and the rate of heat transfer at the wall are significantly altered in the downstream of the constricted region. The axial velocity profile, temperature and flow rate increases with increase in temperature dependent viscosity, while the opposite trend is observed in the case of skin-friction and flow impedance. - Highlights: • We have investigated the pulsatile MHD flow of blood and heat transfer in arteries. • The influence of periodic body acceleration has been taken into account. • The temperature dependent viscosity of blood is considered. • The variable viscosity has an increasing effect on blood flow and heat transfer. • The overall temperature distribution enhances in the presence of magnetic field.

  20. Improved power transfer to wearable systems through stretchable magnetic composites

    Science.gov (United States)

    Lazarus, N.; Bedair, S. S.

    2016-05-01

    The use of wireless power transfer is common in stretchable electronics since physical wiring can be easily destroyed as the system is stretched. This work presents the first demonstration of improved inductive power coupling to a stretchable system through the addition of a thin layer of ferroelastomeric material. A ferroelastomer, an elastomeric polymer loaded with magnetic particulates, has a permeability greater than one while retaining the ability to survive significant mechanical strains. A recently developed ferroelastomer composite based on sendust platelets within a soft silicone elastomer was incorporated into liquid metal stretchable inductors based on the liquid metal galinstan in fluidic channels. For a single-turn inductor, the maximum power transfer efficiency rises from 71 % with no backplane, to 81 % for a rigid ferrite backplane on the transmitter side alone, to 86 % with a ferroelastomer backplane on the receiver side as well. The coupling between a commercial wireless power transmitter coil with ferrite backplane to a five-turn liquid metal inductor was also investigated, finding an improvement in power transfer efficiency from 81 % with only a rigid backplane to 90 % with the addition of the ferroelastomer backplane. Both the single and multi-turn inductors were demonstrated surviving up to 50 % uniaxial applied strain.

  1. A novel macro-model for spin-transfer-torque based magnetic-tunnel-junction elements

    Science.gov (United States)

    Lee, Seungyeon; Lee, Hyunjoo; Kim, Sojeong; Lee, Seungjun; Shin, Hyungsoon

    2010-04-01

    Spin-transfer-torque (STT) switching in magnetic-tunnel-junction (MTJ) has important merits over the conventional field induced magnetic switching (FIMS) MRAM in avoiding half-select problem, and improving scalability and selectivity. Design of MRAM circuitry using STT-based MTJ elements requires an accurate circuit model which exactly emulates the characteristics of an MTJ in a circuit simulator such as HSPICE. This work presents a novel macro-model that fully emulates the important characteristics of STT-based MTJ. The macro-model is realized as a three terminal sub-circuit that reproduces asymmetric resistance versus current (R-I) characteristics and temperature dependence of R-I hysteresis of STT-based MTJ element.

  2. Dependences of the Tunnel Magnetoresistance and Spin Transfer Torque on the Sizes and Concentration of Nanoparticles in Magnetic Tunnel Junctions

    Science.gov (United States)

    Esmaeili, A. M.; Useinov, A. N.; Useinov, N. Kh.

    2018-01-01

    Dependences of the tunnel magnetoresistance and in-plane component of the spin transfer torque on the applied voltage in a magnetic tunnel junction have been calculated in the approximation of ballistic transport of conduction electrons through an insulating layer with embedded magnetic or nonmagnetic nanoparticles. A single-barrier magnetic tunnel junction with a nanoparticle embedded in an insulator forms a double-barrier magnetic tunnel junction. It has been shown that the in-plane component of the spin transfer torque in the double-barrier magnetic tunnel junction can be higher than that in the single-barrier one at the same thickness of the insulating layer. The calculations show that nanoparticles embedded in the tunnel junction increase the probability of tunneling of electrons, create resonance conditions, and ensure the quantization of the conductance in contrast to the tunnel junction without nanoparticles. The calculated dependences of the tunnel magnetoresistance correspond to experimental data demonstrating peak anomalies and suppression of the maximum magnetoresistances at low voltages.

  3. Magnetically Recoverable Supported Ruthenium Catalyst for Hydrogenation of Alkynes and Transfer Hydrogenation of Carbonyl Compounds

    Science.gov (United States)

    A ruthenium (Ru) catalyst supported on magnetic nanoparticles (NiFe2O4) has been successfully synthesized and used for hydrogenation of alkynes at room temperature as well as transfer hydrogenation of a number of carbonyl compounds under microwave irradiation conditions. The cata...

  4. The progress in diagnostic imaging for staging of bladder and prostate cancer. Endorectal magnetic resonance imaging and magnetization transfer contrast

    International Nuclear Information System (INIS)

    Arima, Kiminobu; Hayashi, Norio; Yanagawa, Makoto; Kawamura, Juichi; Kobayashi, Shigeki; Takeda, Kan; Sugimura, Yoshiki

    1999-01-01

    We retrospectively studied the staging accuracy of endorectal magnetic resonance imaging (MRI) in comparison with transrectal ultrasound examination (TRUS) for 71 localized bladder cancers and 19 localized prostate cancers (PC) radically resected. The accuracy of clinical staging for bladder cancer in endorectal MRI and TRUS was 85.9% and 69.2%, respectively. The presence or absence of the continuity of submucosal enhancement on T2-weighted MRI images could be useful for the staging of bladder cancer. The accuracy of the seminal vesicular invasion for prostate cancer in endorectal MRI and TRUS was 95% and 63%, respectively. To determine whether magnetization transfer contrast (MTC) provides additional information in the diagnosis of prostate cancer, the magnetization transfer ratios (MTRs) were calculated in 22 patients with PC, 5 with benign prostatic hyperplasia (BPH) and 4 controls. The mean MTR in the peripheral zone of the normal prostate (8.0%±3.4 [standard deviation]) showed a statistically significant decrease relative to that in the inner zone of the normal prostate (27.4%±3.4, p<0.01), BPH (25.5%±3.7, p<0.01), pre-treatment PC (30.6%±5.9, p<0.01), and PC after hormonal therapy (20.3%±6.3, p<0.01). The mean MTR in pre-treatment PC was significantly higher than that in BPH, or in PC after hormonal therapy (p<0.01). MTC was considered to be useful for conspicuity of prostate cancer lesion. (author)

  5. The magnetization transfer effect in brain studies by 1.5 T magnetic resonance system. When the radiographer should apply it?

    International Nuclear Information System (INIS)

    Ribeiro, M. Margarida; Farinha, Sara; Costa, Joana; Mauricio, J. Cruz; O' Neill, J. Goyri

    2011-01-01

    Purpose: The Magnetization Transfer (MT) obtained by applying a pre-saturation pulse is, in Magnetic Resonance Imaging (MRI), a technique that allows for additional enhancement of lesions on conventional T1 images after contrast administration. This study aims to assess the effectiveness of the technique measuring how MT could improve image quality and diagnostic values through the enhancement of lesions. Methods: Thirteen T1-weighted spin-echo (SE) sequences, obtained by the 1.5 T system after contrast media injection, were analyzed with and without MT. The contrast-to-noise ratio (CNR), as well as the signal-to-noise ratio (SNR) variables were compared in all sequences, according to the reference structures: lateral ventricles, white matter, gray matter, caudate nucleus and internal capsule. The MT ratio average was calculated using the ANOVA scale in order to assess the CNR and the magnetization transfer effect (MTE) for the different lesions and for both sequences (with and without MT). For the assessment of the flow artifact, clinical experts applied a Likert scale with 5 points. Results: For CNR values, the differences between conventional and MT-pulsed images were significant (Student t testp 0,05). Conclusion: In identical conditions of acquisition, the MT does not produce significant differences in the enhancement of lesions, however, it allows a greater capacity to detect the multiple sclerosis plaques, comparing structures around basal nucleus versus gray and white matter.

  6. Identification of compounds with binding affinity to proteins via magnetization transfer from bulk water

    International Nuclear Information System (INIS)

    Dalvit, Claudio; Pevarello, Paolo; Tato, Marco; Veronesi, Marina; Vulpetti, Anna; Sundstroem, Michael

    2000-01-01

    A powerful screening by NMR methodology (WaterLOGSY), based on transfer of magnetization from bulk water, for the identification of compounds that interact with target biomolecules (proteins, RNA and DNA fragments) is described. The method exploits efficiently the large reservoir of H 2 O magnetization. The high sensitivity of the technique reduces the amount of biomolecule and ligands needed for the screening, which constitutes an important requirement for high throughput screening by NMR of large libraries of compounds. Application of the method to a compound mixture against the cyclin-dependent kinase 2 (cdk2) protein is presented

  7. In vitro evaluation of genotoxic effects under magnetic resonant coupling wireless power transfer.

    Science.gov (United States)

    Mizuno, Kohei; Shinohara, Naoki; Miyakoshi, Junji

    2015-04-07

    Wireless power transfer (WPT) technology using the resonant coupling phenomenon has been widely studied, but there are very few studies concerning the possible relationship between WPT exposure and human health. In this study, we investigated whether exposure to magnetic resonant coupling WPT has genotoxic effects on WI38VA13 subcloned 2RA human fibroblast cells. WPT exposure was performed using a helical coil-based exposure system designed to transfer power with 85.4% efficiency at a 12.5-MHz resonant frequency. The magnetic field at the positions of the cell culture dishes is approximately twice the reference level for occupational exposure as stated in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. The specific absorption rate at the positions of the cell culture dishes matches the respective reference levels stated in the ICNIRP guidelines. For assessment of genotoxicity, we studied cell growth, cell cycle distribution, DNA strand breaks using the comet assay, micronucleus formation, and hypoxanthine-guanine phosphoribosyltransferase (HPRT) gene mutation, and did not detect any significant effects between the WPT-exposed cells and control cells. Our results suggest that WPT exposure under the conditions of the ICNIRP guidelines does not cause detectable cellular genotoxicity.

  8. Properties of the transfer matrices of deflecting magnet systems for free electron laser

    International Nuclear Information System (INIS)

    Takao, Masaru

    1993-01-01

    The oscillation of the free electron laser (FEL) requires the high current and low emittance electron beam. The beam transport system should be achromatic and isochronous to preserve the brightness and the emittance of the electron beam. In this paper we clarify the algebraic properties of the transfer matrices of the magnetic deflection system, which is a key component in the beam transport line. (author)

  9. Longitudinal assessment of mouse renal injury using high-resolution anatomic and magnetization transfer MR imaging.

    Science.gov (United States)

    Wang, Feng; Jiang, Rosie; Takahashi, Keiko; Gore, John; Harris, Raymond C; Takahashi, Takamune; Quarles, C Chad

    2014-11-01

    The purpose of this study is to evaluate the utility of high-resolution non-invasive endogenous high-field MRI methods for the longitudinal structural and quantitative assessments of mouse kidney disease using the model of unilateral ureter obstruction (UUO). T1-weighted, T2-weighted and magnetization transfer (MT) imaging protocols were optimized to improve the regional contrast in mouse kidney. Conventional T1 and T2 weighted images were collected in UUO mice on day 0 (~3h), day 1, day 3 and day 6 after injury, on a 7 T small animal MRI system. Cortical and medullary thickness, corticomedullary contrast and Magnetization Transfer Ratio (MTR) were assessed longitudinally. Masson trichrome staining was used to histologically assess changes in tissue microstructure. Over the course of UUO progression there were significant (prenal cortical and medullary atrophy, cortical-medullary differentiation and MTR changes provide an endogenous, non-invasive and quantitative evaluation of renal morphology and tissue composition during UUO progression. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Pathological Assessment of Brain White Matter in Relapsing-Remitting MS Patients using Quantitative Magnetization Transfer Imaging

    Directory of Open Access Journals (Sweden)

    Khodarahm Pahlevan

    2011-09-01

    Full Text Available Introduction: Multiple sclerosis (MS is characterized by lesions in the white matter (WM of the central nervous system. Magnetic resonance imaging is the most specific and sensitive method for diagnosis of multiple sclerosis. However, the ability of conventional MRI to show histopathologic heterogeneity of MS lesions is insufficient. Quantitative magnetization transfer imaging (qMTI is a relatively new method to investigate pathologic processes of the brain tissue occurring in MS patients. Material and Methods: Voxel-based analyses allow regional comparisons between groups to be made for the whole brain in a single analysis. This is done by coregistering data from all individual subjects to a reference brain, generally referred to as the "standard space", and then comparing them on a voxel-by-voxel basis. This study aimed to analyze whole-brain quantitative T1 maps, not to find global changes or changes in selected regions, but specifically to investigate the spatial distribution throughout the brain of T1 increases in MS WM with respect to control WM. In this study, 11 healthy controls, 10 relapsing-remitting (RR MS patients and 13 CIS patients were studied using MT-MRI imaging. MT parameters, including magnetization transfer ratio (MTR, magnetization transfer rate between free protons and restricted macromolecular protons, Ksat and longitudinal relaxation times (with and without MT saturation pulse, T1sat and T1free values were evaluated. Results: The results showed that, at a group level, there is widespread involvement of WM throughout the brain in CIS MS and especially in RRMS, where a significant T1 increase was found in 15.58% of WM voxels (normals < RR. Discussion and Conclusion: This study demonstrates that WM in large parts of the brain is susceptible to disease processes in RR and CIS MS

  11. B1 -sensitivity analysis of quantitative magnetization transfer imaging.

    Science.gov (United States)

    Boudreau, Mathieu; Stikov, Nikola; Pike, G Bruce

    2018-01-01

    To evaluate the sensitivity of quantitative magnetization transfer (qMT) fitted parameters to B 1 inaccuracies, focusing on the difference between two categories of T 1 mapping techniques: B 1 -independent and B 1 -dependent. The B 1 -sensitivity of qMT was investigated and compared using two T 1 measurement methods: inversion recovery (IR) (B 1 -independent) and variable flip angle (VFA), B 1 -dependent). The study was separated into four stages: 1) numerical simulations, 2) sensitivity analysis of the Z-spectra, 3) healthy subjects at 3T, and 4) comparison using three different B 1 imaging techniques. For typical B 1 variations in the brain at 3T (±30%), the simulations resulted in errors of the pool-size ratio (F) ranging from -3% to 7% for VFA, and -40% to > 100% for IR, agreeing with the Z-spectra sensitivity analysis. In healthy subjects, pooled whole-brain Pearson correlation coefficients for F (comparing measured double angle and nominal flip angle B 1 maps) were ρ = 0.97/0.81 for VFA/IR. This work describes the B 1 -sensitivity characteristics of qMT, demonstrating that it varies substantially on the B 1 -dependency of the T 1 mapping method. Particularly, the pool-size ratio is more robust against B 1 inaccuracies if VFA T 1 mapping is used, so much so that B 1 mapping could be omitted without substantially biasing F. Magn Reson Med 79:276-285, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Chiral battery, scaling laws and magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Anand, Sampurn; Bhatt, Jitesh R.; Pandey, Arun Kumar, E-mail: sampurn@prl.res.in, E-mail: jeet@prl.res.in, E-mail: arunp@prl.res.in [Physical Research Laboratory, Ahmedabad, 380009 (India)

    2017-07-01

    We study the generation and evolution of magnetic field in the presence of chiral imbalance and gravitational anomaly which gives an additional contribution to the vortical current. The contribution due to gravitational anomaly is proportional to T {sup 2} which can generate seed magnetic field irrespective of plasma being chirally charged or neutral. We estimate the order of magnitude of the magnetic field to be 10{sup 30} G at T ∼ 10{sup 9} GeV, with a typical length scale of the order of 10{sup −18} cm, which is much smaller than the Hubble radius at that temperature (10{sup −8} cm). Moreover, such a system possess scaling symmetry. We show that the T {sup 2} term in the vorticity current along with scaling symmetry leads to more power transfer from lower to higher length scale as compared to only chiral anomaly without scaling symmetry.

  13. Dissociating proportion congruent and conflict adaptation effects in a Simon-Stroop procedure.

    Science.gov (United States)

    Torres-Quesada, Maryem; Funes, Maria Jesús; Lupiáñez, Juan

    2013-02-01

    Proportion congruent and conflict adaptation are two well known effects associated with cognitive control. A critical open question is whether they reflect the same or separate cognitive control mechanisms. In this experiment, in a training phase we introduced a proportion congruency manipulation for one conflict type (i.e. Simon), whereas in pre-training and post-training phases two conflict types (e.g. Simon and Spatial Stroop) were displayed with the same incongruent-to-congruent ratio. The results supported the sustained nature of the proportion congruent effect, as it transferred from the training to the post-training phase. Furthermore, this transfer generalized to both conflict types. By contrast, the conflict adaptation effect was specific to conflict type, as it was only observed when the same conflict type (either Simon or Stroop) was presented on two consecutive trials (no effect was observed on conflict type alternation trials). Results are interpreted as supporting the reactive and proactive control mechanisms distinction. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Magnetism of DyMn{sub 2} and HoMn{sub 2} - {sup 57}Fe and {sup 119}Sn Moessbauer studies

    Energy Technology Data Exchange (ETDEWEB)

    Krop, K. [University of Min. and Metall., Krakow (Poland). Dept. of Solid State Phys.; Zukrowski, J. [University of Min. and Metall., Krakow (Poland). Dept. of Solid State Phys.; Przewoznik, J. [University of Min. and Metall., Krakow (Poland). Dept. of Solid State Phys.; Marzec, J. [University of Min. and Metall., Krakow (Poland). Dept. of Solid State Phys.; Wiesinger, G. [Institute for Experimental Physics, Technical University, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Haeufler, T. [Institute for Experimental Physics, Technical University, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Hilscher, G. [Institute for Experimental Physics, Technical University, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Steiner, W. [Institute for Applied and Technical Physics, Technical University, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria)

    1995-05-01

    Moessbauer spectra were measured for two Laves phase compounds DyMn{sub 2} and HoMn{sub 2} in which manganese was substituted to 0.5% with {sup 57}Fe and to 0.2% with {sup 119}Sn. At 4.2 K the {sup 57}Fe and {sup 119}Sn spectra of the Dy compound were unambiguously fitted each with two Zeeman patterns (with relative contributions to the spectra 3:1) corresponding to two different Mn sites - magnetic and nonmagnetic. Transferred hyperfine fields at {sup 119}Sn were found to be proportional to the magnetic moment of Dy and its ferromagnetic component, corroborating the magnetic structure found in neutron diffraction (ND) experiment. The same procedure was carried on with the spectra measured for the Ho compound, but the above mentioned proportionality was not found. ((orig.)).

  15. On Electromagnetic Modulation of Flow Instabilities, Mixing and Heat Transfer in Conducting and Magnetized Fluids

    NARCIS (Netherlands)

    Kenjeres, S.

    2016-01-01

    In the present paper we give a concise review of some recent highlights of our research dealing with electromagnetic control of flow, mixing and heat transfer of electrically conductive or magnetized fluids. We apply a combination of state-of-art numerical (DNS and LES) and experimental (PIV and

  16. A 99%-efficiency GaN converter for 6.78 MHz magnetic resonant wireless power transfer system

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Akuzawa

    2014-10-01

    Full Text Available The authors developed a high-efficiency gallium-nitride (GaN Class-E converter for a 6.78 MHz magnetic resonant wireless power transfer system. A negative-bias gate driver circuit made it possible to use a depletion mode GaN high-electron-mobility transistor (HEMT, and simplified the converter circuit. As the depletion mode GaN HEMT with very small gate–source capacitance provided almost ideal zero-voltage switching, the authors attained a drain efficiency of 98.8% and a total efficiency of 97.7%, including power consumption of a gate driver circuit, at a power output of 33 W. In addition, the authors demonstrated a 6.78 MHz magnetic resonant wireless power transfer system that consisted of the GaN Class-E converter, a pair of magnetic resonant coils 150 mm in diameter with an air-gap distance of 40 mm, and a full-bridge rectifier using Si Schottky barrier diodes. The system achieved a dc–dc efficiency of 82.8% at a power output of 25 W. The efficiencies of coil coupling and the rectifier were estimated to be ∼ 94 and 90%, respectively.

  17. Current induced multi-mode propagating spin waves in a spin transfer torque nano-contact with strong perpendicular magnetic anisotropy

    Science.gov (United States)

    Mohseni, S. Morteza; Yazdi, H. F.; Hamdi, M.; Brächer, T.; Mohseni, S. Majid

    2018-03-01

    Current induced spin wave excitations in spin transfer torque nano-contacts are known as a promising way to generate exchange-dominated spin waves at the nano-scale. It has been shown that when these systems are magnetized in the film plane, broken spatial symmetry of the field around the nano-contact induced by the Oersted field opens the possibility for spin wave mode co-existence including a non-linear self-localized spin-wave bullet and a propagating mode. By means of micromagnetic simulations, here we show that in systems with strong perpendicular magnetic anisotropy (PMA) in the free layer, two propagating spin wave modes with different frequency and spatial distribution can be excited simultaneously. Our results indicate that in-plane magnetized spin transfer nano-contacts in PMA materials do not host a solitonic self-localized spin-wave bullet, which is different from previous studies for systems with in plane magnetic anisotropy. This feature renders them interesting for nano-scale magnonic waveguides and crystals since magnon transport can be configured by tuning the applied current.

  18. Aligned Magnetic Field Effects on Flow and Heat Transfer of the Upper-Convected Maxwell Fluid over a Stretching/Shrinking Sheet

    Directory of Open Access Journals (Sweden)

    Waini Iskandar

    2017-01-01

    Full Text Available In this paper, the effect of aligned magnetic field towards the flow and heat transfer of the upper-convected Maxwell (UCM fluid over a stretching/shrinking sheet is numerically studied. The governing partial differential equations are reduced into a system of ordinary differential equations using a similarity transformation, which are then solved numerically using the shooting method. The skin friction and heat transfer coefficients, the velocity, as well as the temperature profiles of the fluid are presented and discussed. Results indicate that an increase in the aligned angle strengthens the applied magnetic field which decrease the velocity and increase the temperature profiles of the fluid. This implies that an increase in the aligned angle increases the skin friction coefficient and decreases the heat transfer coefficients.

  19. A Computational Study on the Magnetic Resonance Coupling Technique for Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Zakaria N.A.

    2017-01-01

    Full Text Available Non-radiative wireless power transfer (WPT system using magnetic resonance coupling (MRC technique has recently been a topic of discussion among researchers. This technique discussed more scenarios in mid-range field of wireless power transmission reflected to the distance and efficiency. The WPT system efficiency varies when the coupling distance between two coils involved changes. This could lead to a decisive issue of high efficient power transfer. This paper presents case studies on the relationship of operating range with the efficiency of the MRC technique. Demonstrative WPT system operates at two different frequencies are projected in order to verify performance. The resonance frequencies used are less than 100MHz within range of 10cm to 20cm.

  20. Charge transfer of He2+ with H in a strong magnetic field

    International Nuclear Information System (INIS)

    Liu Chun-Lei; Zou Shi-Yang; He Bin; Wang Jian-Guo

    2015-01-01

    By solving a time-dependent Schrödinger equation (TDSE), we studied the electron capture process in the He 2+ +H collision system under a strong magnetic field in a wide projectile energy range. The strong enhancement of the total charge transfer cross section is observed for the projectile energy below 2.0 keV/u. With the projectile energy increasing, the cross sections will reduce a little and then increase again, compared with those in the field-free case. The cross sections to the states with different magnetic quantum numbers are presented and analyzed where the influence due to Zeeman splitting is obviously found, especially in the low projectile energy region. The comparison with other models is made and the tendency of the cross section varying with the projectile energy is found closer to that from other close coupling models. (paper)

  1. In Vitro Evaluation of Genotoxic Effects under Magnetic Resonant Coupling Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Kohei Mizuno

    2015-04-01

    Full Text Available Wireless power transfer (WPT technology using the resonant coupling phenomenon has been widely studied, but there are very few studies concerning the possible relationship between WPT exposure and human health. In this study, we investigated whether exposure to magnetic resonant coupling WPT has genotoxic effects on WI38VA13 subcloned 2RA human fibroblast cells. WPT exposure was performed using a helical coil-based exposure system designed to transfer power with 85.4% efficiency at a 12.5-MHz resonant frequency. The magnetic field at the positions of the cell culture dishes is approximately twice the reference level for occupational exposure as stated in the International Commission on Non-Ionizing Radiation Protection (ICNIRP guidelines. The specific absorption rate at the positions of the cell culture dishes matches the respective reference levels stated in the ICNIRP guidelines. For assessment of genotoxicity, we studied cell growth, cell cycle distribution, DNA strand breaks using the comet assay, micronucleus formation, and hypoxanthine-guanine phosphoribosyltransferase (HPRT gene mutation, and did not detect any significant effects between the WPT-exposed cells and control cells. Our results suggest that WPT exposure under the conditions of the ICNIRP guidelines does not cause detectable cellular genotoxicity.

  2. Enhanced saturation magnetization of Fe3Si nanodot-embedded Fe80Si17Nb3 flexible film for efficient wireless power transfer

    International Nuclear Information System (INIS)

    Pai, Yi-Hao; Yan, Zih-Yu; Fu, Ping-Hao

    2013-01-01

    An efficient magnetically coupled resonance response is performed using an iron silicide-based nanostructured magnetoelectric material with high saturation magnetization for the wireless charging of battery-powered consumer electronics. With 500 °C annealing, the self-assembled Fe 3 Si nanodots buried in the Fe 80 Si 17 Nb 3 host matrix with (220) lattice spacing of 1.99 Å corresponding to a volume density of 8.96 × 10 16 cm 3 , can be obtained and a maximum saturation magnetization of 244 emu g −1 achieved. The return loss of the antenna will be tuned to match the designed frequency with greater attenuated intensity (−0.39 dB) and a relatively narrow bandwidth (6 kHz) when the Fe 3 Si nanodot-embedded Fe 80 Si 17 Nb 3 sample is placed in a WiTricity system. An efficient wireless power transfer can be created and improved from 47.5% to 97.3%. The associated coil and loop antenna resonators are significantly readjusted to match the power transfer by putting this nanostructured magnetoelectric material in a WiTricity system. - Highlights: • The saturation magnetization is effective enhancement in the presence of Fe 3 Si nanodot buried in the Fe 80 Si 17 Nb 3 . • A saturation magnetization of 244 emu g −1 is proposed for high-efficiency wireless power transfer. • The return loss of the antenna will be tuned to match the designed frequency. • Such a wireless power transfer can be enhanced efficiency up to 97.3%

  3. Graphene Derivative in Magnetically Recoverable Catalyst Determines Catalytic Properties in Transfer Hydrogenation of Nitroarenes to Anilines with 2-Propanol.

    Science.gov (United States)

    Das, Vijay Kumar; Mazhar, Sumaira; Gregor, Lennon; Stein, Barry D; Morgan, David Gene; Maciulis, Nicholas A; Pink, Maren; Losovyj, Yaroslav; Bronstein, Lyudmila M

    2018-06-14

    Here, we report transfer hydrogenation of nitroarenes to aminoarenes using 2-propanol as a hydrogen source and Ag-containing magnetically recoverable catalysts based on partially reduced graphene oxide (pRGO) sheets. X-ray diffraction and X-ray photoelectron spectroscopy data demonstrated that, during the one-pot catalyst synthesis, formation of magnetite nanoparticles (NPs) is accompanied by the reduction of graphene oxide (GO) to pRGO. The formation of Ag 0 NPs on top of magnetite nanoparticles does not change the pRGO structure. At the same time, the catalyst structure is further modified during the transfer hydrogenation, leading to a noticeable increase of sp 2 carbons. These carbons are responsible for the adsorption of substrate and intermediates, facilitating a hydrogen transfer from Ag NPs and creating synergy between the components of the catalyst. The nitroarenes with electron withdrawing and electron donating substituents allow for excellent yields of aniline derivatives with high regio and chemoselectivity, indicating that the reaction is not disfavored by these functionalities. The versatility of the catalyst synthetic protocol was demonstrated by a synthesis of an Ru-containing graphene derivative based catalyst, also allowing for efficient transfer hydrogenation. Easy magnetic separation and stable catalyst performance in the transfer hydrogenation make this catalyst promising for future applications.

  4. Magnetic nickel ferrite nanoparticles as highly durable catalysts for catalytic transfer hydrogenation of bio-based aldehydes

    DEFF Research Database (Denmark)

    He, Jian; Yang, Song; Riisager, Anders

    2018-01-01

    Magnetic nickel ferrite (NiFe2O4) nanoparticles were exploited as stable and easily separable heterogeneous catalysts for catalytic transfer hydrogenation (CTH) of furfural to furfuryl alcohol with 2-propanol as both the hydrogen source and the solvent providing 94% product yield at 180 degrees C...

  5. Whole brain magnetization transfer histogram analysis of pediatric acute lymphoblastic leukemia patients receiving intrathecal methotrexate therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Akira [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto-shi Kyoto 606-8507 (Japan)]. E-mail: yakira@kuhp.kyoto-u.ac.jp; Miki, Yukio [Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto-shi Kyoto 606-8507 (Japan)]. E-mail: mikiy@kuhp.kyoto-u.ac.jp; Adachi, Souichi [Department of Pediatrics, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto-shi Kyoto 606-8507 (Japan)]. E-mail: sadachi@kuhp.kyoto-u.ac.jp (and others)

    2006-03-15

    Background and purpose: The purpose of this prospective study was to evaluate the hypothesis that magnetization transfer ratio (MTR) histogram analysis of the whole brain could detect early and subtle brain changes nonapparent on conventional magnetic resonance imaging (MRI) in children with acute lymphoblastic leukemia (ALL) receiving methotrexate (MTX) therapy. Materials and methods: Subjects in this prospective study comprised 10 children with ALL (mean age, 6 years; range, 0-16 years). In addition to conventional MRI, magnetization transfer images were obtained before and after intrathecal and intravenous MTX therapy. MTR values were calculated and plotted as a histogram, and peak height and location were calculated. Differences in peak height and location between pre- and post-MTX therapy scans were statistically analyzed. Conventional MRI was evaluated for abnormal signal area in white matter. Results: MTR peak height was significantly lower on post-MTX therapy scans than on pre-MTX therapy scans (p = 0.002). No significant differences in peak location were identified between pre- and post-chemotherapy imaging. No abnormal signals were noted in white matter on either pre- or post-MTX therapy conventional MRI. Conclusions: This study demonstrates that MTR histogram analysis allows better detection of early and subtle brain changes in ALL patients who receive MTX therapy than conventional MRI.

  6. Heat transfer and flow analysis of nanofluid flow between parallel plates in presence of variable magnetic field using HPM

    Energy Technology Data Exchange (ETDEWEB)

    Hatami, M., E-mail: m.hatami@tue.nl [Esfarayen University of Technology, Mechanical Engineering Department, Esfarayen, North Khorasan (Iran, Islamic Republic of); Jing, Dengwei; Song, Dongxing [International Research Center for Renewable Energy, State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi' an 710049 (China); Sheikholeslami, M.; Ganji, D.D. [Department of Mechanical Engineering, Babol University of Technology, Babol (Iran, Islamic Republic of)

    2015-12-15

    In this study, effect of variable magnetic field on nanofluid flow and heat transfer analysis between two parallel disks is investigated. By using the appropriate transformation for the velocity, temperature and concentration, the basic equations governing the flow, heat and mass transfer were reduced to a set of ordinary differential equations. These equations subjected to the associated boundary conditions were solved analytically using Homotopy perturbation method. The analytical investigation is carried out for different governing parameters namely: squeeze number, suction parameter, Hartmann number, Brownian motion parameter, thermophrotic parameter and Lewis number. Results show that Nusselt number has direct relationship with Brownian motion parameter and thermophrotic parameter but it is a decreasing function of squeeze number, suction parameter, Hartmann number and Lewis number. - Highlights: • Heat and mass transfer of nanofluids between parallel plates investigated. • A variable magnetic field is applied on the plates. • Governing equations are solved analytically. • Effects of physical parameters are discussed on the Nusselt number.

  7. Heat transfer and flow analysis of nanofluid flow between parallel plates in presence of variable magnetic field using HPM

    International Nuclear Information System (INIS)

    Hatami, M.; Jing, Dengwei; Song, Dongxing; Sheikholeslami, M.; Ganji, D.D.

    2015-01-01

    In this study, effect of variable magnetic field on nanofluid flow and heat transfer analysis between two parallel disks is investigated. By using the appropriate transformation for the velocity, temperature and concentration, the basic equations governing the flow, heat and mass transfer were reduced to a set of ordinary differential equations. These equations subjected to the associated boundary conditions were solved analytically using Homotopy perturbation method. The analytical investigation is carried out for different governing parameters namely: squeeze number, suction parameter, Hartmann number, Brownian motion parameter, thermophrotic parameter and Lewis number. Results show that Nusselt number has direct relationship with Brownian motion parameter and thermophrotic parameter but it is a decreasing function of squeeze number, suction parameter, Hartmann number and Lewis number. - Highlights: • Heat and mass transfer of nanofluids between parallel plates investigated. • A variable magnetic field is applied on the plates. • Governing equations are solved analytically. • Effects of physical parameters are discussed on the Nusselt number

  8. Performance analysis and experimental verification of mid-range wireless energy transfer through non-resonant magnetic coupling

    DEFF Research Database (Denmark)

    Peng, Liang; Wang, Jingyu; Zhejiang University, Hangzhou, China, L.

    2011-01-01

    In this paper, the efficiency analysis of a mid-range wireless energy transfer system is performed through non-resonant magnetic coupling. It is shown that the self-resistance of the coils and the mutual inductance are critical in achieving a high efficiency, which is indicated by our theoretical...

  9. Energy transfers in large-scale and small-scale dynamos

    Science.gov (United States)

    Samtaney, Ravi; Kumar, Rohit; Verma, Mahendra

    2015-11-01

    We present the energy transfers, mainly energy fluxes and shell-to-shell energy transfers in small-scale dynamo (SSD) and large-scale dynamo (LSD) using numerical simulations of MHD turbulence for Pm = 20 (SSD) and for Pm = 0.2 on 10243 grid. For SSD, we demonstrate that the magnetic energy growth is caused by nonlocal energy transfers from the large-scale or forcing-scale velocity field to small-scale magnetic field. The peak of these energy transfers move towards lower wavenumbers as dynamo evolves, which is the reason for the growth of the magnetic fields at the large scales. The energy transfers U2U (velocity to velocity) and B2B (magnetic to magnetic) are forward and local. For LSD, we show that the magnetic energy growth takes place via energy transfers from large-scale velocity field to large-scale magnetic field. We observe forward U2U and B2B energy flux, similar to SSD.

  10. Design of Novel FBG-Based Sensor of Differential Pressure with Magnetic Transfer

    Directory of Open Access Journals (Sweden)

    Guohui Lyu

    2017-02-01

    Full Text Available In this paper, a differential pressure sensor with magnetic transfer is proposed, in which the non-electric measurement based on the fiber Bragg grating (FBG with the position limiting mechanism is implemented without the direct contact of the sensing unit with the measuring fluid. The test shows that the designed sensor is effective for measuring differential pressure in the range of 0~10 kPa with a sensitivity of 0.0112 nm/kPa, which can be used in environments with high temperature, strong corrosion and high overload measurements.

  11. Design of Novel FBG-Based Sensor of Differential Pressure with Magnetic Transfer.

    Science.gov (United States)

    Lyu, Guohui; Che, Guohang; Li, Junqing; Jiang, Xu; Wang, Keda; Han, Yueqiang; Gao, Laixu

    2017-02-15

    In this paper, a differential pressure sensor with magnetic transfer is proposed, in which the non-electric measurement based on the fiber Bragg grating (FBG) with the position limiting mechanism is implemented without the direct contact of the sensing unit with the measuring fluid. The test shows that the designed sensor is effective for measuring differential pressure in the range of 0~10 kPa with a sensitivity of 0.0112 nm/kPa, which can be used in environments with high temperature, strong corrosion and high overload measurements.

  12. Amide Proton Transfer (APT) MR imaging and Magnetization Transfer (MT) MR imaging of pediatric brain development

    International Nuclear Information System (INIS)

    Zhang, Hong; Kang, Huiying; Peng, Yun; Zhao, Xuna; Jiang, Shanshan; Zhang, Yi; Zhou, Jinyuan

    2016-01-01

    To quantify the brain maturation process during childhood using combined amide proton transfer (APT) and conventional magnetization transfer (MT) imaging at 3 Tesla. Eighty-two neurodevelopmentally normal children (44 males and 38 females; age range, 2-190 months) were imaged using an APT/MT imaging protocol with multiple saturation frequency offsets. The APT-weighted (APTW) and MT ratio (MTR) signals were quantitatively analyzed in multiple brain areas. Age-related changes in MTR and APTW were evaluated with a non-linear regression analysis. The APTW signals followed a decreasing exponential curve with age in all brain regions measured (R"2 = 0.7-0.8 for the corpus callosum, frontal and occipital white matter, and centrum semiovale). The most significant changes appeared within the first year. At maturation, larger decreases in APTW and lower APTW values were found in the white matter. On the contrary, the MTR signals followed an increasing exponential curve with age in the same brain regions measured, with the most significant changes appearing within the initial 2 years. There was an inverse correlation between the MTR and APTW signal intensities during brain maturation. Together with MT imaging, protein-based APT imaging can provide additional information in assessing brain myelination in the paediatric population. (orig.)

  13. Amide Proton Transfer (APT) MR imaging and Magnetization Transfer (MT) MR imaging of pediatric brain development

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hong; Kang, Huiying; Peng, Yun [Beijing Children' s Hospital, Capital Medical University, Imaging Center, Department of Radiology, Beijing (China); Zhao, Xuna [Philips Healthcare, Beijing (China); Jiang, Shanshan; Zhang, Yi; Zhou, Jinyuan [Johns Hopkins University, Division of MR Research, Department of Radiology, Baltimore, MD (United States)

    2016-10-15

    To quantify the brain maturation process during childhood using combined amide proton transfer (APT) and conventional magnetization transfer (MT) imaging at 3 Tesla. Eighty-two neurodevelopmentally normal children (44 males and 38 females; age range, 2-190 months) were imaged using an APT/MT imaging protocol with multiple saturation frequency offsets. The APT-weighted (APTW) and MT ratio (MTR) signals were quantitatively analyzed in multiple brain areas. Age-related changes in MTR and APTW were evaluated with a non-linear regression analysis. The APTW signals followed a decreasing exponential curve with age in all brain regions measured (R{sup 2} = 0.7-0.8 for the corpus callosum, frontal and occipital white matter, and centrum semiovale). The most significant changes appeared within the first year. At maturation, larger decreases in APTW and lower APTW values were found in the white matter. On the contrary, the MTR signals followed an increasing exponential curve with age in the same brain regions measured, with the most significant changes appearing within the initial 2 years. There was an inverse correlation between the MTR and APTW signal intensities during brain maturation. Together with MT imaging, protein-based APT imaging can provide additional information in assessing brain myelination in the paediatric population. (orig.)

  14. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST).

    Science.gov (United States)

    Friedman, Joshua I; Xia, Ding; Regatte, Ravinder R; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates⩾30s(-1)) while simultaneously eliminating signals originating from slower (∼5s(-1)) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST)

    Science.gov (United States)

    Friedman, Joshua I.; Xia, Ding; Regatte, Ravinder R.; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates ⩾ 30 s-1) while simultaneously eliminating signals originating from slower (∼5 s-1) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast.

  16. Radiative transfer in a strongly magnetized plasma. I. Effects of Anisotropy

    International Nuclear Information System (INIS)

    Nagel, W.

    1981-01-01

    We present results of radiative transfer calculations for radiating slabs and columns of strongly magnetized plasma. The angular dependence of the escaping radiation was found numerically by Feautrier's method, using the differential scattering cross sections derived by Ventura. We also give an approximate analytical expression for the anisotropy of the outgoing radiation, based on a system of two coupled diffusion equations for ordinary and extraordinary photons. Giving the polarization dependence of the beaming pattern of radiating slabs as well as columns, we generalize previous results of Basko and Kanno. Some implications for models of the pulsating X-ray source Her X-1 are discussed

  17. Effect of collagen on magnetization transfer contrast assessed in cultured cartilage

    International Nuclear Information System (INIS)

    Aoki, Jun; Seo, Gwy-Suk; Karakida, Osamu; Ueda, Hitoshi; Sone, Shusuke; Hiraki, Yuji; Shukunami, Chisa; Moriya, Hiroto.

    1996-01-01

    We investigated the effect of collagen on magnetization transfer contrast (MTC) in cultured cartilage. In our culture system, only collagen synthesis was increased by the addition of vitamin C, while proteoglycan synthesis and the number of chondrocytes were unaffected. The MTC effect was assessed by using an off-resonance RF pulse (0.3 KHz off-resonance, sinc wave of 18 msec, maximum amplitude 4.61 x 10 -4 T) on a GRASS sequence. The cartilage cultured with vitamin C showed a higher MTC effect than that cultured without vitamin C. The major role of collagen on MTC was confirmed in living cartilage tissue. (author)

  18. Momentum transfer theory of non-conservative charged particle transport in crossed electric and magnetic fields

    International Nuclear Information System (INIS)

    Vrhovac, S.B.; Petrovic, Z.Lj.

    1995-01-01

    Momentum - transfer approximation is applied to momentum and energy balance equations describing reacting particle swarms in gases in crossed electric and magnetic fields. Transport coefficients of charged particles undergoing both inelastic and reactive, non-particle-conserving collisions with a gas of neutral molecules are calculated. Momentum - transfer theory (MTT) has been developed mainly by Robson and collaborators. It has been applied to a single reactive gas and mixtures of reactive gases in electric field only. MTT has also been applied in crossed electric and magnetic fields recently and independently of our work but the reactive collisions were not considered. Consider a swarm of electrons of charge e and mass m moving with velocity rvec v through a neutral gas under the influence of an applied electric rvec E and magnetic rvec B field. The collision processes which we shall investigate are limited to elastic, inelastic and reactive collisions of electrons with gas molecules. Here we interpret reactive collisions as collisions which produce change in number of the swarm particles. Reactive collisions involve creation (ionization by electron impact) or loss (electron attachment) of swarm particles. We consider only single ionization in approximation of the mass ratio m/m 0 0 are masses of electrons and neutral particles, respectively. We assume that the stage of evolution of the swarm is the hydrodynamic limit (HDL). In HDL, the space - time dependence of all properties is carried by the number density n of swarm particles

  19. Magnetization transfer contrast (MTC) and MTC-subtraction: enhancement of cartilage lesions and intracartilaginous degeneration in vitro

    International Nuclear Information System (INIS)

    Vahlensieck, M.; Dombrowski, F.; Leutner, C.; Wagner, U.; Reiser, M.

    1994-01-01

    Human articular cartilage from 16 cadaveric or amputated knees was studied using standard magnetic resonance imaging (MRI), on-resonance magnetization transfer contrast (MTC) and MTC-subtraction MRI. Results were compared with subsequent macroscopic and histopathological findings. MTC-subtraction and T2-weighted spin-echo images visualized cartilaginous surface defects with high sensitivity and specificity. MTC and T2-weighted spin-echo images revealed intra-cartilaginous signal loss without surface defects in 80% of the cases, corresponding to an increased collagen concentration. It is concluded that MTC is sensitive to early cartilage degeneration and MTC-subtraction can be helpful in detecting cartilage defects. (orig.)

  20. Momentum transfer to rotating magnetized plasma from gun plasma injection

    International Nuclear Information System (INIS)

    Shamim, Imran; Hassam, A. B.; Ellis, R. F.; Witherspoon, F. D.; Phillips, M. W.

    2006-01-01

    Numerical simulations are carried out to investigate the penetration and momentum coupling of a gun-injected plasma slug into a rotating magnetized plasma. An experiment along these lines is envisioned for the Maryland Centrifugal Experiment (MCX) [R. F. Ellis et al., Phys. Plasmas 8, 2057 (2001)] using a coaxial plasma accelerator gun developed by HyperV Technologies Corp. [F. D. Witherspoon et al., Bull. Am. Phys. Soc. 50, LP1 87 (2005)]. The plasma gun would be located in the axial midplane and fired off-axis into the rotating MCX plasma annulus. The numerical simulation is set up so that the initial momentum in the injected plasma slug is of the order of the initial momentum of the target plasma. Several numerical firings are done into the cylindrical rotating plasma. Axial symmetry is assumed. The slug is seen to penetrate readily and deform into a mushroom, characteristic of interchange deformations. It is found that up to 25% of the momentum in the slug can be transferred to the background plasma in one pass across a cylindrical chord. For the same initial momentum, a high-speed low density slug gives more momentum transfer than a low-speed high density slug. Details of the numerical simulations and a scaling study are presented

  1. Is white matter affected in adolescents with anorexia nervosa? A study using magnetization transfer imaging.

    Science.gov (United States)

    Akgül, Sinem; Öz, Ayşegül; Karlı-Oğuz, Kader; Kanbur, Nuray; Derman, Orhan

    2016-01-01

    The aim of the study was to assess potential changes in structural integrity of the brain in adolescent patients with Anorexia Nervosa (AN) using the magnetization transfer imaging technique and re-evaluating after nutritional rehabilitation was accomplished. Magnetization transfer ratio (MTR) was used for the detection and quantification of histological changes to the white matter of 9 adolescents diagnosed with AN at diagnosis and after weight gain. Using the MTR technique 6 regions were measured: the pons, left cerebellar hemisphere, amygdala, thalamus, corona radiata and white matter adjacent to the left dorsolateral prefrontal cortex. Scans from the patients with AN were also compared with scans from an age-matched subset of 9 healthy controls. Compared with control subjects, the MTR of participants with AN was no different either at the early stages of diagnosis (p=0.62) or after weight recovery (p=0.81). Similarly, comparison of MTR between patients with AN at diagnoses compared with MTR after weight recovery yielded no statistically significant difference (P=0.33). We conclude that MTR was not able to detect any neuropathological alterations in adolescent patients with AN at either diagnosis or after nutritional recovery and the achievement of weight gain.

  2. Study of the effect of distance and misalignment between magnetically coupled coils for wireless power transfer in intraocular pressure measurement.

    Science.gov (United States)

    Rendon-Nava, Adrian E; Díaz-Méndez, J Alejandro; Nino-de-Rivera, Luis; Calleja-Arriaga, Wilfrido; Gil-Carrasco, Felix; Díaz-Alonso, Daniela

    2014-01-01

    An analysis of the effect of distance and alignment between two magnetically coupled coils for wireless power transfer in intraocular pressure measurement is presented. For measurement purposes, a system was fabricated consisting of an external device, which is a Maxwell-Wien bridge circuit variation, in charge of transferring energy to a biomedical implant and reading data from it. The biomedical implant is an RLC tank circuit, encapsulated by a polyimide coating. Power transfer was done by magnetic induction coupling method, by placing one of the inductors of the Maxwell-Wien bridge circuit and the inductor of the implant in close proximity. The Maxwell-Wien bridge circuit was biased with a 10 MHz sinusoidal signal. The analysis presented in this paper proves that wireless transmission of power for intraocular pressure measurement is feasible with the measurement system proposed. In order to have a proper inductive coupling link, special care must be taken when placing the two coils in proximity to avoid misalignment between them.

  3. Study of the Effect of Distance and Misalignment between Magnetically Coupled Coils for Wireless Power Transfer in Intraocular Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Adrian E. Rendon-Nava

    2014-01-01

    Full Text Available An analysis of the effect of distance and alignment between two magnetically coupled coils for wireless power transfer in intraocular pressure measurement is presented. For measurement purposes, a system was fabricated consisting of an external device, which is a Maxwell-Wien bridge circuit variation, in charge of transferring energy to a biomedical implant and reading data from it. The biomedical implant is an RLC tank circuit, encapsulated by a polyimide coating. Power transfer was done by magnetic induction coupling method, by placing one of the inductors of the Maxwell-Wien bridge circuit and the inductor of the implant in close proximity. The Maxwell-Wien bridge circuit was biased with a 10 MHz sinusoidal signal. The analysis presented in this paper proves that wireless transmission of power for intraocular pressure measurement is feasible with the measurement system proposed. In order to have a proper inductive coupling link, special care must be taken when placing the two coils in proximity to avoid misalignment between them.

  4. Direct characterization of spin-transfer switching of nano-scale magnetic tunnel junctions using a conductive atomic force microscope

    International Nuclear Information System (INIS)

    Lee, Jia-Mou; Yang, Dong-Chin; Lee, Ching-Ming; Ye, Lin-Xiu; Chang, Yao-Jen; Wu, Te-ho; Lee, Yen-Chi; Wu, Jong-Ching

    2013-01-01

    We present an alternative method of spin-transfer-induced magnetization switching for magnetic tunnel junctions (MTJs) using a conductive atomic force microscope (CAFM) with pulsed current. The nominal MTJ cells' dimensions were 200 × 400 nm 2 . The AFM probes were coated with a Pt layer via sputtering to withstand up to several milliamperes. The pulsed current measurements, with pulse duration varying from 5 to 300 ms, revealed a magnetoresistance ratio of up to 120%, and an estimated intrinsic switching current density, based on the thermal activation model, of 3.94 MA cm −2 . This method demonstrates the potential skill to characterize nanometre-scale magnetic devices. (paper)

  5. Laboratory experiments on the magnetic field and neutral density limits on CIV interaction

    International Nuclear Information System (INIS)

    Axnaes, I.; Brenning, N.

    1990-03-01

    Laboratory experiments are reported which determine the magnetic field and neutral density limit for Critical Ionization Velocity (CIV) interaction in the impact configuration. A combination of microwave interferometry and spectroscopy has been used to measure how the electron energy distribution varies with the neutral density and the magnetic field strength. The efficiency of the CIV process is evaluated in terms of the efficiency factor η of energy transfer to the electron. This efficiency is studied as function of the ratio V A /V 0 between the Alfven velocity and the plasma stream velocity and the ratio ν i /ω gi between the ionization frequency and the ion gyro frequency. With other parameters kept constant, V A /V 0 is proportional to the square root of the magnetic field, while ν i /ω gi is proportional to the neutral density. We have found that these two dimensionless parameters are coupled in such a fashion that a stronger magnetic field can compensate for a lower neutral density. For our strongest magnetic field, corresponding to V A /V 0 = 4, CIV interaction is found to occur for a comparatively low value ν i /ω gi ∼ 0.1. For V A /V 0 = 1, we found a clear absence of CIV interaction even for ν i /ω gi approaching unity. (authors)

  6. Transient heat transfer analysis of superconducting magnetic levitating flywheel rotor operating in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Mochida, A.; Kudo, K.; Higasa, H.

    1999-07-01

    In the present study, transient temperature rise is analyzed in a flywheel type power storage system operated in vacuum environment. The flywheel rotor is levitated by high-temperature-superconducting magnetic bearing to reduce the bearing loss. Though the superconductor is cooled by liquid nitrogen, the temperature of the whole system rises due to Joule heating in the coils of the bearings and the motor during the operation. If the temperature should reach the critical temperature of the permanent magnet used for the magnetic bearings after long time operation, the magnetic bearings lose their effect. The heat generated in the levitated rotor diffuses within it by heat conduction and finally emitted to its surrounding solid materials by thermal radiation from the rotor surfaces across vacuum layer. Numerical simulation is carried out calculating the transient radiative-conductive heat transfer and time-dependent profiles of temperature within the rotor are obtained. The results are compared with the experimentally obtained temperatures by measured a test model of 1kWh power storage and the measured profiles of the temperature rise of the rotor fit very well with the calculated ones. Using this simulation tool, the effects of the surface emissivity of the materials of the rotor and the stator, the temperature of the surrounding casings and the thermal conductivity of the materials on the temperature profiles in the system are estimated.

  7. Magnet power supply control of the NSLS VUV and x-ray storage rings transfer lines

    International Nuclear Information System (INIS)

    Klein, J.D.; Ramamoorthy, S.; Singh, O.; Smith, J.D.

    1985-01-01

    The transfer lines for NSLS VUV and x-ray storage rings have been split. New power supplies have been incorporated with existing ones. The existing microprocessor system has been upgraded in order to control the additional functions. This system expands the input/output port of the microprocessor to an addressable serial/parallel link to each magnet power supply. The implementation of this system will be discussed

  8. Using Garlic As A Far-Transfer Problem of Proportional And Probabilistic Reasoning

    OpenAIRE

    Moore, N. T.; Deming, J. C.

    2008-01-01

    The work describes a general problem, which emphasizes proportional reasoning and probabilistic reasoning skills in the context of planting garlic in a backyard garden. Along with practicing these reasoning skills in a context far-removed from the standard high school or college curriculum, our solution involves the development of a few relatively sophisticated statistical concepts, specifically histograms and confidence intervals.

  9. Enhancement of magnetic coupling between permanent magnets and bulk superconductors through iron embedding

    International Nuclear Information System (INIS)

    Seki, H.; Kurabayashi, H.; Suzuki, A.; Ikeda, M.; Akiyama, S.; Murakami, M.

    2009-01-01

    Magnetic torque can be transferred without contact through the coupling of permanent magnets (PM) and bulk superconductors (BSC). For this purpose, permanent magnets should have multiple pole configuration like NSNS. The magnitude of the transferable torque depends on the field strength and the gap between PM and BSC. It was found that the torque decays quickly with the gap. In order to enhance the strength of transferable magnetic torque, we prepared bulk Y-Ba-Cu-O superconductors for which Fe bars are embedded. Holes about 1 mm in diameter were mechanically drilled into bulk Y-Ba-Cu-O, and Fe bars about 0.9 mm in diameter were inserted followed by impregnation of Bi-Pb-Sn alloys with low melting points. The composite of Y-Ba-Cu-O and Fe bars attract magnetic fields generated from permanent magnet before cooling, and thereby magnetic coupling will be improved. We have found that the magnetic torque force can be greatly enhanced through iron embedding.

  10. Magnetization transfer changes of grey and white matter in Parkinson's disease

    International Nuclear Information System (INIS)

    Tambasco, N.; Mancini, M.L.; Paciaroni, M.; Gallai, V.; Pelliccioli, G.P.; Chiarini, P.; Leone, F.; Montanari, G.E.

    2003-01-01

    Since the attempt to evidence structural brain damage in Parkinson's disease (PD) by conventional magnetic resonance imaging (MRI) is usually disappointing, we have investigated whether the magnetization transfer ratio (MTR) can reflect changes in grey and white matter of PD patients. MTR was quantified in 44 regions of interest (ROIs) in both grey and white matter of 11 non-demented PD patients, ranging from 2 to 4 on the Hoehn and Yahr Scale, and eight age-matched healthy subjects. MTR differences between patients and controls were found in the supratentorial white matter and in the brainstem. In particular, lower MTR values were found in the paraventricular white matter of PD patients (p < 0.05) while no differences were observed in corpus callosum, frontal, parietal, occipital lobes or centrum semiovalis. Lower MTR values were found in substantia nigra (p < 0.001), red nucleus (p < 0.05) and pons (p < 0.05) of the patient group. No differences were discovered in basal ganglia and thalamus. These findings suggest that MTR measurements in the paraventricular white matter and brainstem may help to recognize a marker for probable PD. (orig.)

  11. Alfvén wave dynamics at the neighborhood of a 2.5D magnetic null-point

    Science.gov (United States)

    Sabri, S.; Vasheghani Farahani, S.; Ebadi, H.; Hosseinpour, M.; Fazel, Z.

    2018-05-01

    The aim of the present study is to highlight the energy transfer via the interaction of magnetohydrodynamic waves with a 2.5D magnetic null-point in a finite plasma-β regime of the solar corona. An initially symmetric Alfvén pulse at a specific distance from a magnetic null-point is kicked towards the isothermal null-point. A shock-capturing Godunov-type PLUTO code is used to solve the ideal magnetohydrodynamic set equations in the context of wave-plasma energy transfer. As the Alfvén wave propagates towards the magnetic null-point it experiences speed lowering which ends up in releasing energy along the separatrices. In this line owing to the Alfvén wave, a series of events take place that contribute towards coronal heating. Nonlinear induced waves are by products of the torsional Alfvén interaction with magnetic null-points. The energy of these induced waves which are fast magnetoacoustic (transverse) and slow magnetoacoustic (longitudinal) waves are supplied by the Alfvén wave. The nonlinearly induced density perturbations are proportional to the Alfvén wave energy loss. This supplies energy for the propagation of fast and slow magnetoacoustic waves, where in contrast to the fast wave the slow wave experiences a continuous energy increase. As such, the slow wave may transfer its energy to the medium at later times, maintaining a continuous heating mechanism at the neighborhood of a magnetic null-point.

  12. 3D magneto-convective heat transfer in CNT-nanofluid filled cavity under partially active magnetic field

    Science.gov (United States)

    Al-Rashed, Abdullah A. A. A.; Kolsi, Lioua; Oztop, Hakan F.; Aydi, Abdelkarim; Malekshah, Emad Hasani; Abu-Hamdeh, Nidal; Borjini, Mohamed Naceur

    2018-05-01

    A computational study has been performed to investigate the effects of partially active magnetic field on natural convection heat transfer in CNT-nanofluid filled and three-dimensional differentially heated closed space. Two cases are considered to see this effect as magnetic field is applied to upper half (Case I) and lower half (Case II) while remaining walls are insulated. The finite volume method is used to solve governing equations and results are obtained for different governing parameters as Hartmann number (0 ≤ Ha ≤ 100), nanoparticle volume fraction (0 ≤ φ ≤ 0.05) and height of the active zone (0 ≤ LB ≤ 1). It is found that location of magnetic field plays an important role even at the same Hartmann number. Thus, it can be a good parameter to control heat and fluid flow inside the closed space.

  13. Atrophy and magnetization transfer ratio of the corpus callosum in patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Imon, Yukari; Hanyu, Haruo; Iwamoto, Toshihiko; Takasaki, Masaru; Abe, Kimihiko

    1998-01-01

    We compared atrophy and magnetization transfer ratio (MTR) in the corpus callosum in patients with Alzheimer's disease and age-matched normal subjects. Fifteen patients with Alzheimer's disease and fourteen normal subjects received MRI. The corpus callosum was divided into three parts (anterior, middle, and posterior portions) on midsagittal slice, and their areas on T2-weighted reversed images and MTR on magnetization transfer contrast images in each portion were measured. The area and MTR decreased significantly in the posterior portion in patients with Alzheimer's disease. In the anterior portion, MTR decreased significantly, but although the area showed no significant change. In the middle portion, the area and MTR showed no significant change. MTR and the area was correlated in each portion in patients with Alzheimer's disease. The score of Hasegawa dementia scale-revised (HDS-R) and the area of the middle, posterior and total of corpus callosum were significantly related. The score of HDS-R and MTR in the anterior portion of corpus callosum were significantly related. The present study revealed decreases in MTR in the anterior portion of the corpus callosum of patients with Alzheimer's disease although the area showed no significant change, and this change suggests the increase in free water and/or the decrease in bound water in tissues, probably due to demyelination and axonal degeneration. (author)

  14. Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance fingerprinting (MRF).

    Science.gov (United States)

    Cohen, Ouri; Huang, Shuning; McMahon, Michael T; Rosen, Matthew S; Farrar, Christian T

    2018-05-13

    To develop a fast magnetic resonance fingerprinting (MRF) method for quantitative chemical exchange saturation transfer (CEST) imaging. We implemented a CEST-MRF method to quantify the chemical exchange rate and volume fraction of the N α -amine protons of L-arginine (L-Arg) phantoms and the amide and semi-solid exchangeable protons of in vivo rat brain tissue. L-Arg phantoms were made with different concentrations (25-100 mM) and pH (pH 4-6). The MRF acquisition schedule varied the saturation power randomly for 30 iterations (phantom: 0-6 μT; in vivo: 0-4 μT) with a total acquisition time of ≤2 min. The signal trajectories were pattern-matched to a large dictionary of signal trajectories simulated using the Bloch-McConnell equations for different combinations of exchange rate, exchangeable proton volume fraction, and water T 1 and T 2 relaxation times. The chemical exchange rates of the N α -amine protons of L-Arg were significantly (P exchange using saturation power method. Similarly, the L-Arg concentrations determined using MRF were significantly (P exchange rate was well fit (R 2  = 0.9186) by a base catalyzed exchange model. The amide proton exchange rate measured in rat brain cortex (34.8 ± 11.7 Hz) was in good agreement with that measured previously with the water exchange spectroscopy method (28.6 ± 7.4 Hz). The semi-solid proton volume fraction was elevated in white (12.2 ± 1.7%) compared to gray (8.1 ± 1.1%) matter brain regions in agreement with previous magnetization transfer studies. CEST-MRF provides a method for fast, quantitative CEST imaging. © 2018 International Society for Magnetic Resonance in Medicine.

  15. Magnetic design considerations for the SSC vertical bending (BV1C) magnet

    International Nuclear Information System (INIS)

    Venkatraman, V.; Goodzeit, C.; Jayakumar, R.; Nobrega, F.; Snitchler, G.

    1994-01-01

    The BV1C magnet is a large aperture, vertical bending magnet to be used to bend proton beams in the interaction region. An aperture larger than 80 mm is required. The central field has to be a minimum of 6T with a 10% margin. The lattice requirements for field quality are stringent because two counter beams traverse this magnet off the center axis. This magnet's transfer function sag is specified to match closely the transfer function sag of the low beta quadrupoles. With these specifications in mind, suitable designs for the 2-D magnetic cross-sections have been analyzed

  16. Proportionality lost - proportionality regained?

    DEFF Research Database (Denmark)

    Werlauff, Erik

    2010-01-01

    In recent years, the European Court of Justice (the ECJ) seems to have accepted restrictions on the freedom of establishment and other basic freedoms, despite the fact that a more thorough proportionality test would have revealed that the restriction in question did not pass the 'rule of reason' ...

  17. Experimental Evidence on Transfer Pricing

    Directory of Open Access Journals (Sweden)

    Tran Quoc H.

    2016-06-01

    Full Text Available We use incentivized economics experiments to test both the point predictions and comparative static predictions of optimal transfer pricing models, comparing behavior under varying conditions, including wholly versus partially-owned subsidiaries and different tariff and tax rates. As predicted, we find that transfer prices are responsive to relative tax and tariff rates as well as ownership proportions. Additionally, we examine convergence and learning in this setting. While individuals do not choose optimal transfer prices, their choices converge to optimal levels with experience. This paper thus makes two important contributions. First, by comparing behavior with theoretical predictions it provides evidence of whether (and when individuals set transfer prices optimally. Second, by comparing behavior under conditions of full and partial ownership it provides evidence on the impact of policy interventions (like regulating ownership proportions by MNEs on tax revenues.

  18. High-time resolution measurements of upstream magnetic field and plasma conditions during flux transfer events at the Earth's dayside magnetopause

    International Nuclear Information System (INIS)

    Jacob, J.D.; Cattell, C.

    1993-01-01

    This paper presents preliminary analysis of six flux transfer events which were observed simultaneously by IRM and CCE. IRM was able to measure magnetic fields and pressures far from the earth, while CCE made observations at the earth's magnetopause. The objective is to better understand the coupling of energy and momentum into the earth's magnetosphere, by in this case trying to better understand the processes active in flux transfer events. For three of the events the observations were made on common field lines, and IRM observed fluctuations in B z large enough to cause a south to north swing in the interplanetary magnetic field (IMF). Pressure pulses were observed during two of these events. For the other three events there was no such consistent behavior of IMF direction or pressure pulses

  19. A New Scale Factor Adjustment Method for Magnetic Force Feedback Accelerometer

    Directory of Open Access Journals (Sweden)

    Xiangqing Huang

    2017-10-01

    Full Text Available A new and simple method to adjust the scale factor of a magnetic force feedback accelerometer is presented, which could be used in developing a rotating accelerometer gravity gradient instrument (GGI. Adjusting and matching the acceleration-to-current transfer function of the four accelerometers automatically is one of the basic and necessary technologies for rejecting the common mode accelerations in the development of GGI. In order to adjust the scale factor of the magnetic force rebalance accelerometer, an external current is injected and combined with the normal feedback current; they are then applied together to the torque coil of the magnetic actuator. The injected current could be varied proportionally according to the external adjustment needs, and the change in the acceleration-to-current transfer function then realized dynamically. The new adjustment method has the advantages of no extra assembly and ease of operation. Changes in the scale factors range from 33% smaller to 100% larger are verified experimentally by adjusting the different external coefficients. The static noise of the used accelerometer is compared under conditions with and without the injecting current, and the experimental results find no change at the current noise level, which further confirms the validity of the presented method.

  20. A New Scale Factor Adjustment Method for Magnetic Force Feedback Accelerometer.

    Science.gov (United States)

    Huang, Xiangqing; Deng, Zhongguang; Xie, Yafei; Li, Zhu; Fan, Ji; Tu, Liangcheng

    2017-10-27

    A new and simple method to adjust the scale factor of a magnetic force feedback accelerometer is presented, which could be used in developing a rotating accelerometer gravity gradient instrument (GGI). Adjusting and matching the acceleration-to-current transfer function of the four accelerometers automatically is one of the basic and necessary technologies for rejecting the common mode accelerations in the development of GGI. In order to adjust the scale factor of the magnetic force rebalance accelerometer, an external current is injected and combined with the normal feedback current; they are then applied together to the torque coil of the magnetic actuator. The injected current could be varied proportionally according to the external adjustment needs, and the change in the acceleration-to-current transfer function then realized dynamically. The new adjustment method has the advantages of no extra assembly and ease of operation. Changes in the scale factors range from 33% smaller to 100% larger are verified experimentally by adjusting the different external coefficients. The static noise of the used accelerometer is compared under conditions with and without the injecting current, and the experimental results find no change at the current noise level, which further confirms the validity of the presented method.

  1. Heat transfer effects on a viscous dissipative fluid flow past a vertical plate in the presence of induced magnetic field

    Directory of Open Access Journals (Sweden)

    M.C. Raju

    2015-03-01

    Full Text Available A theoretical analysis is performed to study induced magnetic field effects on free convection flow past a vertical plate. The x¯-axis is taken vertically upwards along the plate, y¯-axis normal to the plate into the fluid region. It is assumed that the plate is electrically non-conducting and the applied magnetic field is of uniform strength (H0 and perpendicular to the plate. The magnetic Reynolds number of the flow is not taken to be small enough so that the induced magnetic field is taken into account. The coupled nonlinear partial differential equations are solved by Perturbation technique and the effects of various physical parameters on velocity, temperature, and induced magnetic fields are studied through graphs and tables. Variations in Skin friction and rate of heat transfer are also studied. It is observed that an increase in magnetic parameter decreases the velocity for both water and air. It is also seen that there is a fall in induced magnetic field as magnetic Prandtl number, and magnetic field parameter increase.

  2. A chiral-based magnetic memory device without a permanent magnet.

    Science.gov (United States)

    Ben Dor, Oren; Yochelis, Shira; Mathew, Shinto P; Naaman, Ron; Paltiel, Yossi

    2013-01-01

    Several technologies are currently in use for computer memory devices. However, there is a need for a universal memory device that has high density, high speed and low power requirements. To this end, various types of magnetic-based technologies with a permanent magnet have been proposed. Recent charge-transfer studies indicate that chiral molecules act as an efficient spin filter. Here we utilize this effect to achieve a proof of concept for a new type of chiral-based magnetic-based Si-compatible universal memory device without a permanent magnet. More specifically, we use spin-selective charge transfer through a self-assembled monolayer of polyalanine to magnetize a Ni layer. This magnitude of magnetization corresponds to applying an external magnetic field of 0.4 T to the Ni layer. The readout is achieved using low currents. The presented technology has the potential to overcome the limitations of other magnetic-based memory technologies to allow fabricating inexpensive, high-density universal memory-on-chip devices.

  3. Effects of heat and mass transfer on peristaltic flow of a Bingham fluid in the presence of inclined magnetic field and channel with different wave forms

    International Nuclear Information System (INIS)

    Akram, Safia; Nadeem, S.; Hussain, Anwar

    2014-01-01

    In the present analysis we discussed the influence of heat and mass transfer on the peristaltic flow of a Bingham in an inclined magnetic field and channel with different wave forms. The governing two dimensional equations of momentum, heat and mass transfer are simplified under the assumptions of long wavelength and low Reynolds number approximation. The exact solutions of momentum, heat and mass transfer are calculated. Finally, graphical behaviors of various physical parameters are also discussed through the graphical behavior of pressure rise, pressure gradient, temperature concentration and stream functions. - Highlights: • Combine effects of heat and mass transfer on peristaltic flow problem is discussed. • Effects of inclined magnetic field and channel on new fluid model are discussed. • Effects of different wave forms are also discussed in the present flow problem

  4. Tritium assay in hydrogen gas by proportional counter with magnetic tape recording

    International Nuclear Information System (INIS)

    Grabczak, J.

    1982-03-01

    Analytical procedure is discussed concerning routine tritium activity determination in water samples based on hydrogen production from the water sample and radioactivity measurement by gas proportional counting. The method was found to be fully comparable to the widely adopted technique of liquid scintillation counting with electrolytic enrichment

  5. Installation of the LHC transfer lines begins

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. The first installation phase will continue until mid-April. In addition to the magnets, a beam dump facility also has to be installed. The second installation phase will take place later this year and should be completed in 2004, when the TI 8 transfer line is due to be tested. The second transfer line, in tunnel TI 2, should be ready in April 2007, once the LHC magnets have been transported through the downstream section of this tunnel.Pho...

  6. Installation of the LHC transfer lines begins

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. In this way the magnet is delivered directly to its installation point, but beneath the beamline. It is then raised into its final position in the beamline using air cushions, which form an integrated part of the transport system.Photo 01: Pictured with the newly installed magnet and transport system in the transfer line tunnel are (left to right) Volker Mertens, responsible for the LHC injection and transfer lines; personnel involved in tr...

  7. Installation of the LHC transfer lines begins

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. The first installation phase will continue until mid-April. In addition to the magnets, a beam dump facility also has to be installed. The second installation phase will take place later this year and should be completed in 2004, when the TI 8 transfer line is due to be tested. The second transfer line, in tunnel TI 2, should be ready in April 2007, once the LHC magnets have been transported through the downstream section of this tunnel. Th...

  8. Installation of the LHC transfer lines begins

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. The first installation phase will continue until mid-April. In addition to the magnets, a beam dump facility also has to be installed. The second installation phase will take place later this year and should be completed in 2004, when the TI 8 transfer line is due to be tested. The second transfer line, in tunnel TI 2, should be ready in April 2007, once the LHC magnets have been transported through the downstream section of this tunnel. We...

  9. Numerical study of MHD nanofluid flow and heat transfer past a bidirectional exponentially stretching sheet

    International Nuclear Information System (INIS)

    Ahmad, Rida; Mustafa, M.; Hayat, T.; Alsaedi, A.

    2016-01-01

    Recent advancements in nanotechnology have led to the discovery of new generation coolants known as nanofluids. Nanofluids possess novel and unique characteristics which are fruitful in numerous cooling applications. Current work is undertaken to address the heat transfer in MHD three-dimensional flow of magnetic nanofluid (ferrofluid) over a bidirectional exponentially stretching sheet. The base fluid is considered as water which consists of magnetite–Fe 3 O 4 nanoparticles. Exponentially varying surface temperature distribution is accounted. Problem formulation is presented through the Maxwell models for effective electrical conductivity and effective thermal conductivity of nanofluid. Similarity transformations give rise to a coupled non-linear differential system which is solved numerically. Appreciable growth in the convective heat transfer coefficient is observed when nanoparticle volume fraction is augmented. Temperature exponent parameter serves to enhance the heat transfer from the surface. Moreover the skin friction coefficient is directly proportional to both magnetic field strength and nanoparticle volume fraction. - Highlights: • Nanofluid flow due to exponentially stretching sheet. • Exponentially varying surface temperature distribution is accounted. • Sparrow–Gregg type Hills (SGH) for temperature distribution exist. • Numerical values of local Nusselt number are presented. • Cooling performance of ferrofluid is superior to pure water.

  10. Bias-voltage dependence of perpendicular spin-transfer torque in asymmetric MgO-based magnetic tunnel junctions

    KAUST Repository

    Oh, Se Chung

    2009-10-25

    Spin-transfer torque (STT) allows the electrical control of magnetic states in nanostructures. The STT in magnetic tunnel junctions (MTJs) is of particular importance owing to its potential for device applications. It has been demonstrated that the MTJ has a sizable perpendicular STT (, field-like torque), which substantially affects STT-driven magnetization dynamics. In contrast to symmetric MTJs where the bias dependence of is quadratic, it is theoretically predicted that the symmetry breaking of the system causes an extra linear bias dependence. Here, we report experimental results that are consistent with the predicted linear bias dependence in asymmetric MTJs. The linear contribution is quite significant and its sign changes from positive to negative as the asymmetry is modified. This result opens a way to design the bias dependence of the field-like term, which is useful for device applications by allowing, in particular, the suppression of the abnormal switching-back phenomena. © 2009 Macmillan Publishers Limited. All rights reserved.

  11. Multiscale modeling of current-induced switching in magnetic tunnel junctions using ab initio spin-transfer torques

    Science.gov (United States)

    Ellis, Matthew O. A.; Stamenova, Maria; Sanvito, Stefano

    2017-12-01

    There exists a significant challenge in developing efficient magnetic tunnel junctions with low write currents for nonvolatile memory devices. With the aim of analyzing potential materials for efficient current-operated magnetic junctions, we have developed a multi-scale methodology combining ab initio calculations of spin-transfer torque with large-scale time-dependent simulations using atomistic spin dynamics. In this work we introduce our multiscale approach, including a discussion on a number of possible schemes for mapping the ab initio spin torques into the spin dynamics. We demonstrate this methodology on a prototype Co/MgO/Co/Cu tunnel junction showing that the spin torques are primarily acting at the interface between the Co free layer and MgO. Using spin dynamics we then calculate the reversal switching times for the free layer and the critical voltages and currents required for such switching. Our work provides an efficient, accurate, and versatile framework for designing novel current-operated magnetic devices, where all the materials details are taken into account.

  12. Bias-voltage dependence of perpendicular spin-transfer torque in asymmetric MgO-based magnetic tunnel junctions

    KAUST Repository

    Oh, Se Chung; Park, Seung Young; Manchon, Aurelien; Chshiev, Mairbek; Han, Jae Ho; Lee, Hyun Woo; Lee, Jang Eun; Nam, Kyung Tae; Jo, Younghun; Kong, Yo Chan; Dieny, Bernard; Lee, Kyung Jin

    2009-01-01

    Spin-transfer torque (STT) allows the electrical control of magnetic states in nanostructures. The STT in magnetic tunnel junctions (MTJs) is of particular importance owing to its potential for device applications. It has been demonstrated that the MTJ has a sizable perpendicular STT (, field-like torque), which substantially affects STT-driven magnetization dynamics. In contrast to symmetric MTJs where the bias dependence of is quadratic, it is theoretically predicted that the symmetry breaking of the system causes an extra linear bias dependence. Here, we report experimental results that are consistent with the predicted linear bias dependence in asymmetric MTJs. The linear contribution is quite significant and its sign changes from positive to negative as the asymmetry is modified. This result opens a way to design the bias dependence of the field-like term, which is useful for device applications by allowing, in particular, the suppression of the abnormal switching-back phenomena. © 2009 Macmillan Publishers Limited. All rights reserved.

  13. Reconnection at the earth's magnetopause - Magnetic field observations and flux transfer events

    Science.gov (United States)

    Russell, C. T.

    1984-01-01

    Theoretical models of plasma acceleration by magnetic-field-line reconnection at the earth magnetopause and the high-resolution three-dimensional plasma measurements obtained with the ISEE satellites are compared and illustrated with diagrams, graphs, drawings, and histograms. The history of reconnection theory and the results of early satellite observations are summarized; the thickness of the magnetopause current layer is discussed; problems in analyzing the polarization of current-layer rotation are considered; and the flux-transfer events responsible for periods of patchy reconnection are characterized in detail. The need for further observations and refinements of the theory to explain the initiation of reconnection and identify the mechanism determining whether it is patchy or steady-state is indicated.

  14. Ruthenium supported on magnetic nanoparticles: An efficient and recoverable catalyst for hydrogenation of alkynes and transfer hydrogenation of carbonyl compounds

    Science.gov (United States)

    Ruthenium supported on surface modified magnetic nanoparticles (NiFe2O4) has been successfully synthesized and applied for hydrogenation of alkynes at room temperature as well as transfer hydrogenation of a number of carbonyl compounds under microwave irradiation conditions. The ...

  15. Active Magnetic Regenerative Liquefier

    Energy Technology Data Exchange (ETDEWEB)

    Barclay, John A. [Heracles Energy Corporation d.b.a. Prometheus Energy, Washington, DC (United States); Oseen-Send, Kathryn [Heracles Energy Corporation d.b.a. Prometheus Energy, Washington, DC (United States); Ferguson, Luke [Heracles Energy Corporation d.b.a. Prometheus Energy, Washington, DC (United States); Pouresfandiary, Jamshid [Heracles Energy Corporation d.b.a. Prometheus Energy, Washington, DC (United States); Cousins, Anand [Heracles Energy Corporation d.b.a. Prometheus Energy, Washington, DC (United States); Ralph, Heather [Heracles Energy Corporation d.b.a. Prometheus Energy, Washington, DC (United States); Hampto, Tom [Heracles Energy Corporation d.b.a. Prometheus Energy, Washington, DC (United States)

    2016-01-12

    This final report for the DOE Project entitled Active Magnetic Regenerative Liquefier (AMRL) funded under Grant DE-FG36-08GO18064 to Heracles Energy Corporation d.b.a. Prometheus Energy (Heracles/Prometheus) describes an active magnetic regenerative refrigerator (AMRR) prototype designed and built during the period from July 2008 through May 2011. The primary goal of this project was to make significant technical advances toward highly efficient liquefaction of hydrogen. Conventional hydrogen liquefiers at any scale have a maximum FOM of ~0.35 due primarily to the intrinsic difficulty of rapid, efficient compression of either hydrogen or helium working gases. Numerical simulation modeling of high performance AMRL designs indicates certain designs have promise to increase thermodynamic efficiency from a FOM of ~0.35 toward ~0.5 to ~0.6. The technical approach was the use of solid magnetic working refrigerants cycled in and out of high magnetic fields to build an efficient active regenerative magnetic refrigeration module providing cooling power for AMRL. A single-stage reciprocating AMRR with a design temperature span from ~290 K to ~120 K was built and tested with dual magnetic regenerators moving in and out of the conductively-cooled superconducting magnet subsystem. The heat transfer fluid (helium) was coupled to the process stream (refrigeration/liquefaction load) via high performance heat exchangers. In order to maximize AMRR efficiency a helium bypass loop with adjustable flow was incorporated in the design because the thermal mass of magnetic refrigerants is higher in low magnetic field than in high magnetic field. Heracles/Prometheus designed experiments to measure AMRR performance under a variety of different operational parameters such as cycle frequency, magnetic field strength, heat transfer fluid flow rate, amount of bypass flow of the heat transfer fluid while measuring work input, temperature span, cooling capability as a function of cold temperature

  16. Proportional reasoning

    DEFF Research Database (Denmark)

    Dole, Shelley; Hilton, Annette; Hilton, Geoff

    2015-01-01

    Proportional reasoning is widely acknowledged as a key to success in school mathematics, yet students’ continual difficulties with proportion-related tasks are well documented. This paper draws on a large research study that aimed to support 4th to 9th grade teachers to design and implement tasks...

  17. Magnetic design of a FFAG superconducting magnet

    International Nuclear Information System (INIS)

    Obana, T.; Ogitsu, T.; Nakamoto, T.; Sasaki, K.; Yamamoto, A.; Yoshimoto, M.; Mori, Y.; Orikasa, T.

    2005-01-01

    A superconducting magnet for a Fixed Field Alternating Gradient (FFAG) accelerator has been proposed. The required magnetic field is static and proportional to the k-th power of the orbit radius where k is the geometrical field index of the accelerator. In 2D, the required magnetic field can be generated with the optimized cross section of the coil. The cross section of the coils is a left-right asymmetry to simplify the cross section and ellipse to downsize the magnet. Local and integral 3D fields along the beam trajectory are evaluated with using new type of 3D coil configuration

  18. Small polaron hopping in magnetic semiconductors

    International Nuclear Information System (INIS)

    Emin, D.; Liu, N.L.H.

    1978-01-01

    In a number of magnetic insulators it has been hypothesized that the charge carriers form small polarons. The transfer of an electron between magnetic sites and how the magnetic nature of the material affects the rate which characterizes small-polaron hops between magnetic sites were studied. The basic transfer processes are addressed from a many-electron point in which the itinerant electron is treated as indistinguishable from those which contribute unpaired spins at the magnetic sites

  19. Wireless energy transfer through non-resonant magnetic coupling

    DEFF Research Database (Denmark)

    Peng, Liang; Breinbjerg, Olav; Mortensen, Asger

    2010-01-01

    could be properly designed to minimize undesired energy dissipation in the source coil when the power receiver is out of the range. Our basic observation paves the way for more flexible design and fabrication of non-resonant mid-range wireless energy transfer systems, thus potentially impacting......We demonstrate by theoretical analysis and experimental verification that mid-range wireless energy transfer systems may take advantage of de-tuned coupling devices, without jeopardizing the energy transfer efficiency. Allowing for a modest de-tuning of the source coil, energy transfer systems...... practical implementations of wireless energy transfer....

  20. Three-dimensional numerical modelling of a magnetically deflected dc transferred arc in argon

    CERN Document Server

    Blais, A; Boulos, M I

    2003-01-01

    The aim of this work is to develop a numerical model for the deflection of dc transferred arcs using an external magnetic field as a first step into the modelling of industrial arc furnaces. The arc is deflected by the use of a conductor aligned parallel to the arc axis through which flows an electric current. The model is validated by comparing the results of axisymmetric calculations to modelling results from the scientific literature. The present model is found to be a good representation of the electric dc arc as differences with the literature are easily explained by model parameters such as the critical boundary conditions at the electrodes. Transferred arc cases exhibit the expected behaviour as the temperature T, the velocity v-vector and the electrical potential drop DELTA phi all increase with the arc current I and the argon flow rate Q. Three-dimensional geometry is implemented, enabling one to numerically deflect the arc. For the deflected arc cases, the deflection increases with the arc current I...

  1. Heat transfer to liquid sodium in a straight duct in the presence of a transverse magnetic field and a gravity field

    International Nuclear Information System (INIS)

    Majid, A.

    1998-01-01

    Heat transfer to liquid sodium in the presence of a transverse magnetic field and gravity field was analyzed in a square cross section straight duct. The duct had conducting vanadium walls. Magnetohydrodynamic equations in three dimensions and energy equation in three dimensions in cartesian coordinate system were solved. Firstly Nusselt number was calculated with no magnetic field and gravity field. Secondly the Nusselt number was calculated for the case of transverse magnetic field acting on the fluid. Thirdly Nusselt number was calculated for the case of transverse magnetic field and gravity field acting on the fluid. Only one face of the channel was heated. It was found that Nusselt number is not sensitive to application of gravity field and is slightly sensitive to application of transverse magnetic field. The sensitivity of Nusselt number to magnetic field intensity becomes almost negligible after increasing the strength of magnetic field to 0.1 Tesla. (author)

  2. Enhanced saturation magnetization of Fe{sub 3}Si nanodot-embedded Fe{sub 80}Si{sub 17}Nb{sub 3} flexible film for efficient wireless power transfer

    Energy Technology Data Exchange (ETDEWEB)

    Pai, Yi-Hao, E-mail: paiyihao@mail.ndhu.edu.tw; Yan, Zih-Yu; Fu, Ping-Hao

    2013-07-15

    An efficient magnetically coupled resonance response is performed using an iron silicide-based nanostructured magnetoelectric material with high saturation magnetization for the wireless charging of battery-powered consumer electronics. With 500 °C annealing, the self-assembled Fe{sub 3}Si nanodots buried in the Fe{sub 80}Si{sub 17}Nb{sub 3} host matrix with (220) lattice spacing of 1.99 Å corresponding to a volume density of 8.96 × 10{sup 16} cm{sup 3}, can be obtained and a maximum saturation magnetization of 244 emu g{sup −1} achieved. The return loss of the antenna will be tuned to match the designed frequency with greater attenuated intensity (−0.39 dB) and a relatively narrow bandwidth (6 kHz) when the Fe{sub 3}Si nanodot-embedded Fe{sub 80}Si{sub 17}Nb{sub 3} sample is placed in a WiTricity system. An efficient wireless power transfer can be created and improved from 47.5% to 97.3%. The associated coil and loop antenna resonators are significantly readjusted to match the power transfer by putting this nanostructured magnetoelectric material in a WiTricity system. - Highlights: • The saturation magnetization is effective enhancement in the presence of Fe{sub 3}Si nanodot buried in the Fe{sub 80}Si{sub 17}Nb{sub 3}. • A saturation magnetization of 244 emu g{sup −1} is proposed for high-efficiency wireless power transfer. • The return loss of the antenna will be tuned to match the designed frequency. • Such a wireless power transfer can be enhanced efficiency up to 97.3%.

  3. Theoretical predictions for spatially-focused heating of magnetic nanoparticles guided by magnetic particle imaging field gradients

    Energy Technology Data Exchange (ETDEWEB)

    Dhavalikar, Rohan [Department of Chemical Engineering, University of Florida, 1030 Center Drive, Gainesville, FL 32611 (United States); Rinaldi, Carlos, E-mail: carlos.rinaldi@bme.ufl.edu [Department of Chemical Engineering, University of Florida, 1030 Center Drive, Gainesville, FL 32611 (United States); J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, 1275 Center Drive, Gainesville, FL 32611 (United States)

    2016-12-01

    Magnetic nanoparticles in alternating magnetic fields (AMFs) transfer some of the field's energy to their surroundings in the form of heat, a property that has attracted significant attention for use in cancer treatment through hyperthermia and in developing magnetic drug carriers that can be actuated to release their cargo externally using magnetic fields. To date, most work in this field has focused on the use of AMFs that actuate heat release by nanoparticles over large regions, without the ability to select specific nanoparticle-loaded regions for heating while leaving other nanoparticle-loaded regions unaffected. In parallel, magnetic particle imaging (MPI) has emerged as a promising approach to image the distribution of magnetic nanoparticle tracers in vivo, with sub-millimeter spatial resolution. The underlying principle in MPI is the application of a selection magnetic field gradient, which defines a small region of low bias field, superimposed with an AMF (of lower frequency and amplitude than those normally used to actuate heating by the nanoparticles) to obtain a signal which is proportional to the concentration of particles in the region of low bias field. Here we extend previous models for estimating the energy dissipation rates of magnetic nanoparticles in uniform AMFs to provide theoretical predictions of how the selection magnetic field gradient used in MPI can be used to selectively actuate heating by magnetic nanoparticles in the low bias field region of the selection magnetic field gradient. Theoretical predictions are given for the spatial decay in energy dissipation rate under magnetic field gradients representative of those that can be achieved with current MPI technology. These results underscore the potential of combining MPI and higher amplitude/frequency actuation AMFs to achieve selective magnetic fluid hyperthermia (MFH) guided by MPI. - Highlights: • SAR predictions based on a field-dependent magnetization relaxation model.

  4. Spin transfer driven resonant expulsion of a magnetic vortex core for efficient rf detector

    Directory of Open Access Journals (Sweden)

    S. Menshawy

    2017-05-01

    Full Text Available Spin transfer magnetization dynamics have led to considerable advances in Spintronics, including opportunities for new nanoscale radiofrequency devices. Among the new functionalities is the radiofrequency (rf detection using the spin diode rectification effect in spin torque nano-oscillators (STNOs. In this study, we focus on a new phenomenon, the resonant expulsion of a magnetic vortex in STNOs. This effect is observed when the excitation vortex radius, due to spin torques associated to rf currents, becomes larger than the actual radius of the STNO. This vortex expulsion is leading to a sharp variation of the voltage at the resonant frequency. Here we show that the detected frequency can be tuned by different parameters; furthermore, a simultaneous detection of different rf signals can be achieved by real time measurements with several STNOs having different diameters. This result constitutes a first proof-of-principle towards the development of a new kind of nanoscale rf threshold detector.

  5. Dependence of the amount of open magnetic flux on the direction of the interplanetary magnetic field

    International Nuclear Information System (INIS)

    Akasofu, S.I.; Ahn, B.H.

    1980-01-01

    The power generated by the solar wind-magnetosphere dynamo is proportional to the amount of the open magnetic flux phi. It is difficult to use this fact in determining observationally the dependence of phi on the orientation of the interplanetary magnetic field vector. It is shown that, for a simple vacuum superposition of the earth's dipole field and a uniform magnetic field, PHI is very closely proportional to sin(theta/2) for a wide range of the intensity of the uniform field, where theta denotes the polar angle of the interplanetary magnetic field vector in the Y-Z plane of solar-magnetospheric coordinates. (author)

  6. Current transfer in dc non-transferred arc plasma torches

    International Nuclear Information System (INIS)

    Ghorui, S; Sahasrabudhe, S N; Das, A K

    2010-01-01

    Fundamentals of current transfer to the anodes in dc non-transferred arc plasma torches are investigated. Specially designed anodes made of three mutually isolated sections and external dc axial magnetic fields of various strengths are utilized to explore the conditions for different diffused and constricted attachments of the arc with the anode. A number of new facts are revealed in the exercise. Under constricted attachment, formation of arc root takes place. Spontaneous and magnetically induced movements of the arc root, their dependence on the arc current and the strength of the external magnetic field, most probable arc root velocity, variation of the root velocity with strength of the applied magnetic field, the effect of swirl on the rotational speed of the arc root are some of the important features investigated. Two new techniques are introduced: one for measurement of the arc root diameter and the other for determination of the negative electric field in the boundary layer over the anode. While the first one exploits the rigid column behaviour of the arcs, the second one utilizes the shooting back of the residual electrons over an arc spot. Sample calculations are provided.

  7. Numerical Investigation of Fluid Flow and Heat Transfer Inside a 2D Enclosure with Three Hot Obstacles on the Ramp under the Influence of a Magnetic Field

    Directory of Open Access Journals (Sweden)

    M. M. Keshtkar

    2017-06-01

    Full Text Available This paper focuses on solving the fluid flow and heat transfer equations inside a two-dimensional square enclosure containing three hot obstacles affected by gravity and magnetic force placed on a ramp using Boltzmann method (LBM applying multiple relaxation times (MRT. Although, the Lattice Boltzmann with MRT is a complex technique, it is a relatively new, stable, fast and high-accurate one. The main objective of this research was to numerically model the fluid flow and ultimately obtaining the velocity field, flow and temperature contour lines inside a two-dimensional enclosure. The results and their comparisons for different types of heat transfer revealed that free or forced heat transfer has a considerable impact on the heat transfer and stream lines. This can be controlled by modifying the Richardson number. It is revealed that changing the intensity of the magnetic field (Hartman number has an appreciable effect on the heat transfer.

  8. Installation of the LHC transfer lines begins

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. In this way the magnet is delivered directly to its installation point, but beneath the beamline. It is then raised into its final position in the beamline using air cushions, which form an integrated part of the transport system. Here we see the transport vehicle alongside the magnet supports. Visible in the background is the first magnet in place.

  9. Assessment of the patellofemoral cartilage: Correlation of knee pain score with magnetic resonance cartilage grading and magnetization transfer ratio asymmetry of glycosaminoglycan chemical exchange saturation transfer.

    Science.gov (United States)

    Lee, Young Han; Yang, Jaemoon; Jeong, Ha-Kyu; Suh, Jin-Suck

    2017-01-01

    Biochemical imaging of glycosaminoglycan chemical exchange saturation transfer (gagCEST) could predict the depletion of glycosaminoglycans (GAG) in early osteoarthritis. The purpose of this study was to evaluate the relationship between the magnetization transfer ratio asymmetry (MTR asym ) of gagCEST images and visual analog scale (VAS) pain scores in the knee joint. This retrospective study was approved by the institutional review board. A phantom study was performed using hyaluronic acid to validate the MTR asym values of gagCEST images. Knee magnetic resonance (MR) images of 22 patients (male, 9; female, 13; mean age, 50.3years; age range; 25-79years) with knee pain were included in this study. The MR imaging (MRI) protocol involved standard knee MRI as well as gagCEST imaging, which allowed region-of-interest analyses of the patellar facet and femoral trochlea. The MTR asym at 1.0ppm was calculated at each region. The cartilages of the patellar facets and femoral trochlea were graded according to the Outerbridge classification system. Data regarding the VAS scores of knee pain were collected from the electronic medical records of the patients. Statistical analysis was performed using Spearman's correlation. The results of the phantom study revealed excellent correlation between the MTR asym values and the concentration of GAGs (r=0.961; p=0.003). The cartilage grades on the MR images showed significant negative correlation with the MTR asym values in the patellar facet and femoral trochlea (r=-0.460; p=0.031 and r=-0.543; p=0.009, respectively). The VAS pain scores showed significant negative correlation with the MTR asym values in the patellar facet and femoral trochlea (r=-0.435; p=0.043 and r=-0.671; p=0.001, respectively). The pain scores were associated with the morphological and biochemical changes in articular cartilages visualized on knee MR images. The biochemical changes, visualized in terms of the MTR asym values of the gagCEST images, exhibited

  10. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J. [Department of Radiology, ' ' Aretaieion' ' Hospital,University of Athens Medical School, Athens (Greece); Voumvourakis, C.; Sfagos, C. [Department of Neurology, ' ' Eginiteion' ' Hospital, University of Athens Medical School, Athens (Greece)

    2004-03-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  11. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    International Nuclear Information System (INIS)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J.; Voumvourakis, C.; Sfagos, C.

    2004-01-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  12. Magnetic resonant wireless power transfer for propulsion of implantable micro-robot

    Science.gov (United States)

    Kim, D.; Kim, M.; Yoo, J.; Park, H.-H.; Ahn, S.

    2015-05-01

    Recently, various types of mobile micro-robots have been proposed for medical and industrial applications. Especially in medical applications, a motor system for propulsion cannot easily be used in a micro-robot due to their small size. Therefore, micro-robots are usually actuated by controlling the magnitude and direction of an external magnetic field. However, for micro-robots, these methods in general are only applicable for moving and drilling operations, but not for the undertaking of various missions. In this paper, we propose a new micro-robot concept, which uses wireless power transfer to deliver the propulsion force and electric power simultaneously. The mechanism of Lorentz force generation and the coil design methodologies are explained, and validation of the proposed propulsion system for a micro-robot is discussed thorough a simulation and with actual measurements with up-scaled test vehicles.

  13. Thermomagnetic convection of a magnetic nanofluid influenced by a magnetic field

    Directory of Open Access Journals (Sweden)

    Bouhrour Ali

    2017-01-01

    Full Text Available We present a numerical study of thermomagnetic convection in a differentially heated cavity. The magnetic nanofluid (ferrofluid is subjected to a uniform magnetic gradient oriented at an angle, φ, with respect to the thermal gradient. The motivation for this work stems largely from a desire to extent preexisting works focused on horizontal and vertical orientations φ = 0°, 90°, 180°, and 270°. Our main goal is to get data on the flow and heat transfer for any orientation in the entire range 0-360°. The generalized problem lends itself to the investigation of orientations that give maximum heat transfer. It is found that, (1 at a given magneto- gravitational coupling number, N, orientations 0°, 90°, and 270°, for which magnetization gradient is unstable, are not the optimum ones, (2 for 0 1, a second maximum occur between 0° and 90° owing to reverse flow phenomenon, (4 at strong magnetic gradients, the two heat transfer peaks take the same value, and (5 optimization parameter, ω, reflecting the strongest magnetic effect, grows with N. Unlike the gravity, magnetic gradient may supply various strengths and spatial configurations, which makes thermomagnetic convection more controllable. Also, the magnetic mechanism is a viable alternative for the gravity one in microgravity, where thermo-gravitational convection ceases to be efficient..

  14. Heat transfer enhancement

    International Nuclear Information System (INIS)

    Hasatani, Masanobu; Itaya, Yoshinori

    1985-01-01

    In order to develop energy-saving techniques and new energy techniques, and also most advanced techniques by making industrial equipment with high performance, heat transfer performance frequently becomes an important problem. In addition, the improvement of conventional heat transfer techniques and the device of new heat transfer techniques are often required. It is most proper that chemical engineers engage in the research and development for enhancing heat transfer. The research and development for enhancing heat transfer are important to heighten heat exchange efficiency or to cool equipment for preventing overheat in high temperature heat transfer system. In this paper, the techniques of enhancing radiative heat transfer and the improvement of radiative heat transfer characteristics are reported. Radiative heat transfer is proportional to fourth power of absolute temperature, and it does not require any heat transfer medium, but efficient heat-radiation converters are necessary. As the techniques of enhancing radiative heat transfer, the increase of emission and absorption areas, the installation of emissive structures and the improvement of radiative characteristics are discussed. (Kako, I.)

  15. Delineation of cortical pathology in multiple sclerosis using multi-surface magnetization transfer ratio imaging

    Directory of Open Access Journals (Sweden)

    David A. Rudko

    2016-01-01

    Full Text Available The purpose of our study was to evaluate the utility of measurements of cortical surface magnetization transfer ratio (csMTR on the inner, mid and outer cortical boundaries as clinically accessible biomarkers of cortical gray matter pathology in multiple sclerosis (MS. Twenty-five MS patients and 12 matched controls were recruited from the MS Clinic of the Montreal Neurological Institute. Anatomical and magnetization transfer ratio (MTR images were acquired using 3 Tesla MRI at baseline and two-year time-points. MTR maps were smoothed along meshes representing the inner, mid and outer neocortical boundaries. To evaluate csMTR reductions suggestive of sub-pial demyelination in MS patients, a mixed model analysis was carried out at both the individual vertex level and in anatomically parcellated brain regions. Our results demonstrate that focal areas of csMTR reduction are most prevalent along the outer cortical surface in the superior temporal and posterior cingulate cortices, as well as in the cuneus and precentral gyrus. Additionally, age regression analysis identified that reductions of csMTR in MS patients increase with age but appear to hit a plateau in the outer caudal anterior cingulate, as well as in the precentral and postcentral cortex. After correction for the naturally occurring gradient in cortical MTR, the difference in csMTR between the inner and outer cortex in focal areas in the brains of MS patients correlated with clinical disability. Overall, our findings support multi-surface analysis of csMTR as a sensitive marker of cortical sub-pial abnormality indicative of demyelination in MS patients.

  16. Cu-water nanofluid flow induced by a vertical stretching sheet in presence of a magnetic field with convective heat transfer

    Directory of Open Access Journals (Sweden)

    Kalidas Das

    2017-09-01

    Full Text Available The convective heat transfer performance of nanofluid over a permeable stretching sheet with thermal convective boundary condition in presence of magnetic field and slip velocity is studied in the present paper. Cu-water nanofluid is used to investigate the effect of nanoparticles on the flow and heat transfer characteristic. The numerical results are compared with published results and are found in an excellent agreement. The influences of various relevant parameters on the velocity and temperature as well as the rate of shear stress and the rate of heat transfer are elucidated through graphs and tables. It is observed that nanoparticles volume fraction and surface convection parameter both increase the thickness of thermal boundary layer.

  17. Installation of the LHC transfer lines begins

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. In this way the magnet is delivered directly to its installation point, but beneath the beamline. It is then raised into its final position in the beamline using air cushions, which form an integrated part of the transport system.Photos 01, 02: Pictured with the newly installed magnet and transport system in the transfer line tunnel are LHC project leader Lyn Evans (second left, white helmet); Volker Mertens, responsible for the LHC injecti...

  18. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis; Resonancia magnetica con contraste y transferencia de magnetizacion en el estudio seriado de pacientes con esclerosis multiple

    Energy Technology Data Exchange (ETDEWEB)

    Rovira, A; Alonso, J; Cucurella, G; Nos, C; Tintore, M; Pedraza, S; Rio, J; Montalban, X [Hospital General i Universitari Vall d` Hebron. Barcelona (Spain)

    1998-12-31

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs.

  19. Pulsed laser induced heat transfer from a phthalocyanine-based thin film to a Bi, Al-substituted DyIG substrate: photothermal demagnetization observed by magnetic circular dichroism and numerical analysis.

    Science.gov (United States)

    Karasawa, Masanobu; Ishii, Kazuyuki

    2018-05-03

    We have investigated the demagnetization of a ferrimagnetic substrate, Bi, Al-substituted dysprosium iron garnet (Bi0.8Dy2.2Fe4.3Al0.7O12), based on selective pulsed laser irradiation of a molecular thin film consisting of μ-oxo-bis[hydroxyl{2,9(or 10),16(or 17),23(or 24)-tetra-tert-butylphthalocyanato}silicon] ((SiPc)2) and poly(vinylidene fluoride), and succeeded in reproducing photothermal energy transfer from a molecular thin film to an inorganic magnetic substrate in a submicrometer-order and a submicrosecond time scale using numerical analysis. After the instant temperature rise due to nanosecond pulsed laser irradiation of the (SiPc)2-based film, followed by heat transfer from the film to the neighboring magnetic substrate, demagnetization of the magnetic substrate was spectroscopically monitored by the decrease in its magnetic circular dichroism (MCD) intensity. The MCD intensity decreased with increasing pulsed laser energy, which reflects the fact that the submicrometer-order region of the substrate was demagnetized as a result of temperature rise reaching high Curie temperature. This heat transfer phenomenon resulting in the demagnetization of the magnetic substrate was numerically analyzed in a submicrometer-order and a submicrosecond time scale using the finite difference method: the demagnetized regions were calculated to be the same order of magnitude as those experimentally evaluated. These results would provide a more detailed understanding of photothermal energy transfer in organic-inorganic hybrid materials, which would be useful for developing photofunctional materials.

  20. Expression of Heat Shock Proteins in Human Fibroblast Cells under Magnetic Resonant Coupling Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Kohei Mizuno

    2015-10-01

    Full Text Available Since 2007, resonant coupling wireless power transfer (WPT technology has been attracting attention and has been widely researched for practical use. Moreover, dosimetric evaluation has also been discussed to evaluate the potential health risks of the electromagnetic field from this WPT technology based on the International Commission on Non-Ionizing Radiation Protection (ICNIRP guidelines. However, there has not been much experimental evaluation of the potential health risks of this WPT technology. In this study, to evaluate whether magnetic resonant coupling WPT induces cellular stress, we focused on heat shock proteins (Hsps and determined the expression level of Hsps 27, 70 and 90 in WI38VA13 subcloned 2RA human fibroblast cells using a western blotting method. The expression level of Hsps under conditions of magnetic resonant coupling WPT for 24 h was not significantly different compared with control cells, although the expression level of Hsps for cells exposed to heat stress conditions was significantly increased. These results suggested that exposure to magnetic resonant coupling WPT did not cause detectable cell stress.

  1. Spin Transfer Torque in Graphene

    Science.gov (United States)

    Lin, Chia-Ching; Chen, Zhihong

    2014-03-01

    Graphene is an idea channel material for spin transport due to its long spin diffusion length. To develop graphene based spin logic, it is important to demonstrate spin transfer torque in graphene. Here, we report the experimental measurement of spin transfer torque in graphene nonlocal spin valve devices. Assisted by a small external in-plane magnetic field, the magnetization reversal of the receiving magnet is induced by pure spin diffusion currents from the injector magnet. The magnetization switching is reversible between parallel and antiparallel configurations by controlling the polarity of the applied charged currents. Current induced heating and Oersted field from the nonlocal charge flow have also been excluded in this study. Next, we further enhance the spin angular momentum absorption at the interface of the receiving magnet and graphene channel by removing the tunneling barrier in the receiving magnet. The device with a tunneling barrier only at the injector magnet shows a comparable nonlocal spin valve signal but lower electrical noise. Moreover, in the same preset condition, the critical charge current density for spin torque in the single tunneling barrier device shows a substantial reduction if compared to the double tunneling barrier device.

  2. Oscillatory magneto-convection under magnetic field modulation

    Directory of Open Access Journals (Sweden)

    Palle Kiran

    2018-03-01

    Full Text Available In this paper we investigate an oscillatory mode of nonlinear magneto-convection under time dependant magnetic field. The time dependant magnetic field consists steady and oscillatory parts. The oscillatory part of the imposed magnetic field is assumed to be of third order. An externally imposed vertical magnetic field in an electrically conducting horizontal fluid layer is considered. The finite amplitude analysis is discussed while perturbing the system. The complex Ginzburg-Landau model is used to derive an amplitude of oscillatory convection for weakly nonlinear mode. Heat transfer is quantified in terms of the Nusselt number, which is governed by the Landau equation. The variation of the modulation excitation of the magnetic field alternates heat transfer in the layer. The modulation excitation of the magnetic field is used either to enhance or diminish the heat transfer in the system. Further, it is found that, oscillatory mode of convection enhances the heat transfer and than stationary convection. The results have possible technological applications in magnetic fluid based systems involving energy transmission. Keywords: Weakly nonlinear theory, Oscillatory convection, Complex Ginzburg Landau model, Magnetic modulation

  3. Pressure drop and heat transfer of a mercury single-phase flow and an air-mercury two-phase flow in a helical tube under a strong magnetic field

    International Nuclear Information System (INIS)

    Takahashi, Minoru; Momozaki, Yoichi

    2000-01-01

    For the reduction of a large magneto-hydrodynamic (MHD) pressure drop of a liquid metal single-phase flow, a liquid metal two-phase flow cooling system has been proposed. As a fundamental study, MHD pressure drops and heat transfer characteristics of a mercury single-phase flow and an air-mercury two-phase flow were experimentally investigated. A strong transverse magnetic field relevant to the fusion reactor conditions was applied to the mercury single-phase flow and the air-mercury two-phase flow in a helically coiled tube that was inserted in the vertical bore of a solenoidal superconducting magnet. It was found that MHD pressure drops of a mercury single-phase flow in the helically coiled tube were nearly equal to those in a straight tube. The Nusselt number at an outside wall was higher than that at an inside wall both in the mercury single-phase flow in the absence and presence of a magnetic field. The Nusselt number of the mercury single-phase flow decreased, increased and again decreased with an increase in the magnetic flux density. MHD pressure drops did not decrease appreciably by injecting air into a mercury flow and changing the mercury flow into the air-mercury two-phase flow. Remarkable heat transfer enhancement did not appear by the air injection. The injection of air into the mercury flow enhanced heat transfer in the ranges of high mercury flow rate and low magnetic flux density, possibly due to the agitation effect of air bubbles. The air injection deteriorated heat transfer in the range of low mercury flow rates possibly because of the occupation of air near heating wall

  4. Correlation between charge transfer and exchange coupling in carbon-based magnetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Anh Tuan, E-mail: tuanna@hus.edu.vn [Faculty of Physics, VNU University of Science, 334 Nguyen Trai, Thanh Xuan, Ha Noi (Viet Nam); Science and Technology Department, Vietnam National University, Hanoi, 144 Xuan Thuy, Cau Giay, Hanoi (Viet Nam); Japan Advanced Institute of Science and Technology, 1-1, Asahidai, Nomi, Ishikawa, 923-1292 Japan (Japan); Nguyen, Van Thanh; Nguyen, Huy Sinh [Faculty of Physics, VNU University of Science, 334 Nguyen Trai, Thanh Xuan, Ha Noi (Viet Nam); Pham, Thi Tuan Anh [Faculty of Physics, VNU University of Science, 334 Nguyen Trai, Thanh Xuan, Ha Noi (Viet Nam); Faculty of Science, College of Hai Duong, Nguyen Thi Due, Hai Duong (Viet Nam); Do, Viet Thang [Faculty of Physics, VNU University of Science, 334 Nguyen Trai, Thanh Xuan, Ha Noi (Viet Nam); Faculty of Science, Haiphong University, 171 Phan Dang Luu, Kien An, Hai Phong (Viet Nam); Dam, Hieu Chi [Japan Advanced Institute of Science and Technology, 1-1, Asahidai, Nomi, Ishikawa, 923-1292 Japan (Japan)

    2015-10-15

    Several forms of carbon-based magnetic materials, i.e. single radicals, radical dimers, and alternating stacks of radicals and diamagnetic molecules, have been investigated using density-functional theory with dispersion correction and full geometry optimization. Our calculated results demonstrate that the C{sub 31}H{sub 15} (R{sub 4}) radical has a spin of ½. However, in its [R{sub 4}]{sub 2} dimer structure, the net spin becomes zero due to antiferromagnetic spin-exchange between radicals. To avoid antiferromagnetic spin-exchange of identical face-to-face radicals, eight alternating stacks, R{sub 4}/D{sub 2m}/R{sub 4} (with m = 3-10), were designed. Our calculated results show that charge transfer (Δn) between R{sub 4} radicals and the diamagnetic molecule D{sub 2m} occurs with a mechanism of spin exchange (J) in stacks. The more electrons that transfer from R{sub 4} to D{sub 2m}, the stronger the ferromagnetic spin-exchange in stacks. In addition, our calculated results show that Δn can be tailored by adjusting the electron affinity (E{sub a}) of D{sub 2m}. The correlation between Δn, E{sub a}, m, and J is discussed. These results give some hints for the design of new ferromagnetic carbon-based materials.

  5. Kalman Filtered Bio Heat Transfer Model Based Self-adaptive Hybrid Magnetic Resonance Thermometry.

    Science.gov (United States)

    Zhang, Yuxin; Chen, Shuo; Deng, Kexin; Chen, Bingyao; Wei, Xing; Yang, Jiafei; Wang, Shi; Ying, Kui

    2017-01-01

    To develop a self-adaptive and fast thermometry method by combining the original hybrid magnetic resonance thermometry method and the bio heat transfer equation (BHTE) model. The proposed Kalman filtered Bio Heat Transfer Model Based Self-adaptive Hybrid Magnetic Resonance Thermometry, abbreviated as KalBHT hybrid method, introduced the BHTE model to synthesize a window on the regularization term of the hybrid algorithm, which leads to a self-adaptive regularization both spatially and temporally with change of temperature. Further, to decrease the sensitivity to accuracy of the BHTE model, Kalman filter is utilized to update the window at each iteration time. To investigate the effect of the proposed model, computer heating simulation, phantom microwave heating experiment and dynamic in-vivo model validation of liver and thoracic tumor were conducted in this study. The heating simulation indicates that the KalBHT hybrid algorithm achieves more accurate results without adjusting λ to a proper value in comparison to the hybrid algorithm. The results of the phantom heating experiment illustrate that the proposed model is able to follow temperature changes in the presence of motion and the temperature estimated also shows less noise in the background and surrounding the hot spot. The dynamic in-vivo model validation with heating simulation demonstrates that the proposed model has a higher convergence rate, more robustness to susceptibility problem surrounding the hot spot and more accuracy of temperature estimation. In the healthy liver experiment with heating simulation, the RMSE of the hot spot of the proposed model is reduced to about 50% compared to the RMSE of the original hybrid model and the convergence time becomes only about one fifth of the hybrid model. The proposed model is able to improve the accuracy of the original hybrid algorithm and accelerate the convergence rate of MR temperature estimation.

  6. On the Origin of Sub-subgiant Stars. II. Binary Mass Transfer, Envelope Stripping, and Magnetic Activity

    Energy Technology Data Exchange (ETDEWEB)

    Leiner, Emily; Mathieu, Robert D. [Department of Astronomy, University of Wisconsin-Madison, 475 North Charter Street, Madison, WI 53706 (United States); Geller, Aaron M., E-mail: leiner@astro.wisc.edu [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA) and Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208 (United States)

    2017-05-10

    Sub-subgiant stars (SSGs) lie to the red of the main sequence and fainter than the red giant branch in cluster color–magnitude diagrams (CMDs), a region not easily populated by standard stellar evolution pathways. While there has been speculation on what mechanisms may create these unusual stars, no well-developed theory exists to explain their origins. Here we discuss three hypotheses of SSG formation: (1) mass transfer in a binary system, (2) stripping of a subgiant’s envelope, perhaps during a dynamical encounter, and (3) reduced luminosity due to magnetic fields that lower convective efficiency and produce large starspots. Using the stellar evolution code MESA, we develop evolutionary tracks for each of these hypotheses, and compare the expected stellar and orbital properties of these models with six known SSGs in the two open clusters M67 and NGC 6791. All three of these mechanisms can create stars or binary systems in the SSG CMD domain. We also calculate the frequency with which each of these mechanisms may create SSG systems, and find that the magnetic field hypothesis is expected to create SSGs with the highest frequency in open clusters. Mass transfer and envelope stripping have lower expected formation frequencies, but may nevertheless create occasional SSGs in open clusters. They may also be important mechanisms to create SSGs in higher mass globular clusters.

  7. Molecular orbital (SCF-X-α-SW) theory of Fe2+-Mn3+, Fe3+-Mn2+, and Fe3+-Mn3+ charge transfer and magnetic exchange in oxides and silicates

    Science.gov (United States)

    Sherman, David M.

    1990-01-01

    Metal-metal charge-transfer and magnetic exchange interactions have important effects on the optical spectra, crystal chemistry, and physics of minerals. Previous molecular orbital calculations have provided insight on the nature of Fe2+-Fe3+ and Fe2+-Ti4+ charge-transfer transitions in oxides and silicates. In this work, spin-unrestricted molecular orbital calculations on (FeMnO10) clusters are used to study the nature of magnetic exchange and electron delocalization (charge transfer) associated with Fe3+-Mn2+, Fe3+-Mn3+, and Fe2+-Mn3+ interactions in oxides and silicates. 

  8. Magnetic Emissions Reduction by Varying Secondary Side Capacitor for Ferrite Geometry based Series-Parallel Topology Wireless Power Transfer to Vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Magnetic fields in surroundings of wireless power transfer system depends upon the two coil currents, distance from the coils and space angle between the two coil fields in steady state conditions. Increase in value of the secondary capacitor leads to a phase shift between the two currents and as...

  9. Magnetic-flux pump

    Science.gov (United States)

    Hildebrandt, A. F.; Elleman, D. D.; Whitmore, F. C. (Inventor)

    1966-01-01

    A magnetic flux pump is described for increasing the intensity of a magnetic field by transferring flux from one location to the magnetic field. The device includes a pair of communicating cavities formed in a block of superconducting material, and a piston for displacing the trapped magnetic flux into the secondary cavity producing a field having an intense flux density.

  10. Dielectrophoresis-magnetophoresis force driven magnetic nanoparticle movement in transformer oil based magnetic fluids.

    Science.gov (United States)

    Lee, Jong-Chul; Lee, Sangyoup

    2013-09-01

    Magnetic fluid is a stable colloidal mixture contained magnetic nanoparticles coated with a surfactant. Recently, it was found that the fluid has properties to increase heat transfer and dielectric characteristics due to the added magnetic nanoparticles in transformer oils. The magnetic nanoparticles in the fluid experience an electrical force directed toward the place of maximum electric field strength when the electric field is applied. And when the external magnetic field is applied, the magnetic nanoparticles form long chains oriented along the direction of the field. The behaviors of magnetic nanoparticles in both the fields must play an important role in changing the heat transfer and dielectric characteristics of the fluids. In this study, we visualized the movement of magnetic nanoparticles influenced by both the fields applied in-situ. It was found that the magnetic nanoparticles travel in the region near the electrode by the electric field and form long chains along the field direction by the magnetic field. It can be inferred that the movement of magnetic nanoparticles appears by both the fields, and the breakdown voltage of transformer oil based magnetic fluids might be influenced according to the dispersion of magnetic nanoparticles.

  11. Phosphorus-31 NMR magnetization transfer measurements of metabolic reaction rates in the rat heart and kidney in vivo

    International Nuclear Information System (INIS)

    Koretsky, A.P.

    1984-01-01

    31 P NMR is a unique tool to study bioenergetics in living cells. The application of magnetization transfer techniques to the measurement of steady-state enzyme reaction rates provides a new approach to understanding the regulation of high energy phosphate metabolism. This dissertation is concerned with the measurement of the rates of ATP synthesis in the rat kidney and of the creatine kinase catalyzed reaction in the rat heart in situ. The theoretical considerations of applying magnetization transfer techniques to intact organs are discussed with emphasis on the problems associated with multiple exchange reactions and compartmentation of reactants. Experimental measurements of the ATP synthesis rate were compared to whole kidney oxygen consumption and Na + reabsorption rates to derive ATP/O values. The problems associated with ATP synthesis rate measurements in kidney, e.g. the heterogeneity of the inorganic phosphate resonance, are discussed and experiments to overcome these problems proposed. In heart, the forward rate through creatine kinase was measured to be larger than the reverse rate. To account for the difference in forward and reverse rates a model is proposed based on the compartmentation of a small pool of ATP

  12. Three-dimensional numerical modelling of a magnetically deflected dc transferred arc in argon

    International Nuclear Information System (INIS)

    Blais, A; Proulx, P; Boulos, M I

    2003-01-01

    The aim of this work is to develop a numerical model for the deflection of dc transferred arcs using an external magnetic field as a first step into the modelling of industrial arc furnaces. The arc is deflected by the use of a conductor aligned parallel to the arc axis through which flows an electric current. The model is validated by comparing the results of axisymmetric calculations to modelling results from the scientific literature. The present model is found to be a good representation of the electric dc arc as differences with the literature are easily explained by model parameters such as the critical boundary conditions at the electrodes. Transferred arc cases exhibit the expected behaviour as the temperature T, the velocity v-vector and the electrical potential drop Δφ all increase with the arc current I and the argon flow rate Q. Three-dimensional geometry is implemented, enabling one to numerically deflect the arc. For the deflected arc cases, the deflection increases with the arc current I and conductor current I conductor and decreases with the flow rate Q and x 0 , the arc-conductor distance. These deflection behaviours are explained using physical arguments

  13. Multiferroicity in an organic charge-transfer salt that is suggestive of electric-dipole-driven magnetism

    Science.gov (United States)

    Lunkenheimer, Peter; Müller, Jens; Krohns, Stephan; Schrettle, Florian; Loidl, Alois; Hartmann, Benedikt; Rommel, Robert; de Souza, Mariano; Hotta, Chisa; Schlueter, John A.; Lang, Michael

    2012-09-01

    Multiferroics, showing simultaneous ordering of electrical and magnetic degrees of freedom, are remarkable materials as seen from both the academic and technological points of view. A prominent mechanism of multiferroicity is the spin-driven ferroelectricity, often found in frustrated antiferromagnets with helical spin order. There, as for conventional ferroelectrics, the electrical dipoles arise from an off-centre displacement of ions. However, recently a different mechanism, namely purely electronic ferroelectricity, where charge order breaks inversion symmetry, has attracted considerable interest. Here we provide evidence for ferroelectricity, accompanied by antiferromagnetic spin order, in a two-dimensional organic charge-transfer salt, thus representing a new class of multiferroics. We propose a charge-order-driven mechanism leading to electronic ferroelectricity in this material. Quite unexpectedly for electronic ferroelectrics, dipolar and spin order arise nearly simultaneously. This can be ascribed to the loss of spin frustration induced by the ferroelectric ordering. Hence, here the spin order is driven by the ferroelectricity, in marked contrast to the spin-driven ferroelectricity in helical magnets.

  14. Magnetic resonance elastometry using a single-sided permanent magnet

    International Nuclear Information System (INIS)

    Tan, Carl S; Marble, Andrew E; Ono, Yuu

    2012-01-01

    In this paper, we describe a magnetic resonance method of measuring material elasticity using a single-sided magnet with a permanent static field gradient. This method encodes sample velocity in a reciprocal space using Hahn spin-echoes with variable timing. The experimental results show a strong correlation between magnetic resonance signal attenuation and elasticity when an oscillating force is applied on the sample. This relationship in turn provides us with information about the displacement velocity experienced by the sample, which is inversely proportional to Young's modulus. The proposed method shows promise in offering a portable and cost-effective magnetic resonance elastography system. (paper)

  15. Control of the proportion of inner cells by asymmetric divisions and the ensuing resilience of cloned rabbit embryos

    Science.gov (United States)

    Duranthon, Véronique

    2018-01-01

    ABSTRACT Mammalian embryo cloning by nuclear transfer has a low success rate. This is hypothesized to correlate with a high variability of early developmental steps that segregate outer cells, which are fated to extra-embryonic tissues, from inner cells, which give rise to the embryo proper. Exploring the cell lineage of wild-type embryos and clones, imaged in toto until hatching, highlights the respective contributions of cell proliferation, death and asymmetric divisions to phenotypic variability. Preferential cell death of inner cells in clones, probably pertaining to the epigenetic plasticity of the transferred nucleus, is identified as a major difference with effects on the proportion of inner cell. In wild type and clones, similar patterns of outer cell asymmetric divisions are shown to be essential to the robust proportion of inner cells observed in wild type. Asymmetric inner cell division, which is not described in mice, is identified as a regulator of the proportion of inner cells and likely gives rise to resilient clones. PMID:29567671

  16. Group Analysis of Free Convection Flow of a Magnetic Nanofluid with Chemical Reaction

    Directory of Open Access Journals (Sweden)

    Md. Jashim Uddin

    2015-01-01

    Full Text Available A theoretical study of two-dimensional magnetohydrodynamics viscous incompressible free convective boundary layer flow of an electrically conducting, chemically reacting nanofluid from a convectively heated permeable vertical surface is presented. Scaling group of transformations is used in the governing equations and the boundary conditions to determine absolute invariants. A third-order ordinary differential equation which corresponds to momentum conservation and two second-order ordinary differential equations which correspond to energy and nanoparticle volume fraction (species conservation are derived. Our (group analysis indicates that, for the similarity solution, the convective heat transfer coefficient and mass transfer velocity are proportional to x-1/4 whilst the reaction rate is proportional to x-1/2, where x is the axial distance from the leading edge of the plate. The effects of the relevant controlling parameters on the dimensionless velocity, temperature, and nanoparticle volume fraction are examined. The accuracy of the technique we have used was tested by performing comparisons with the results of published work and the results were found to be in good agreement. The present computations indicate that the flow is accelerated and temperature enhanced whereas nanoparticle volume fractions are decreased with increasing order of chemical reaction. Furthermore the flow is strongly decelerated, whereas the nanoparticle volume fraction and temperature are enhanced with increasing magnetic field parameter. Increasing convection-conduction parameter increases velocity and temperatures but has a weak influence on nanoparticle volume fraction distribution. The present study demonstrates the thermal enhancement achieved with nanofluids and also magnetic fields and is of relevance to nanomaterials processing.

  17. Contributions to the methodology of multiwire proportional chambers

    International Nuclear Information System (INIS)

    Petrascu, H.

    1993-01-01

    The Ph.D. thesis presents first the realization, testing, optimization, and use of detection equipment based on position sensitive multiwire proportional chambers (MWPC), high resolution proportional counters, and of ΔE,E ionization chambers. In the second chapter it is presented the realization MWPC, in which the coordinate information is obtained by means of LC-delay lines, containing many original constructive elements. By using a system of three MWPC in coincidence, an experimental testing of the theoretically predicted pion generation in the 235 U fission process, was performed. An upper limit of 10 -11 for this process was found. In the 3-rd chapter there are presented the developments of high resolution proportional counters for X-ray spectrometry. Various penning mixtures of high purity gases were studied. The purity of gases was assured by a technology described in a Romanian patents. These counters are currently use in various applications as a rapid analysis of steel marks and in the mining industry. the 4-th chapter is dedicated to the construction and using of ΔE,E closed, high resolution ionization chambers. With these chambers the multinucleon transfer in the 27 Al( 14 M, X) reaction at 116 MeV bombarding energy was investigated. Also this type of chambers was used for the elaboration of an absolute method for analysis and profiling of impurities in silicon wafers. This method is described in the last part of the chapter. (Author) 117 Figs., 8 Tabs., 55 Refs

  18. Numerical analysis of the shifting slabs applied in a wireless power transfer system to enhance magnetic coupling

    Science.gov (United States)

    Dong, Yayun; Yang, Xijun; Jin, Nan; Li, Wenwen; Yao, Chen; Tang, Houjun

    2017-05-01

    Shifting medium is a kind of metamaterial, which can optically shift a space or an object a certain distance away from its original position. Based on the shifting medium, we propose a concise pair of shifting slabs covering the transmitting or receiving coil in a two-coil wireless power transfer system to decrease the equivalent distance between the coils. The electromagnetic parameters of the shifting slabs are calculated by transformation optics. Numerical simulations validate that the shifting slabs can approximately shift the electromagnetic fields generated by the covered coil; thus, the magnetic coupling and the efficiency of the system are enhanced while remaining the physical transmission distance unchanged. We also verify the advantages of the shifting slabs over the magnetic superlens. Finally, we provide two methods to fabricate shifting slabs based on split-ring resonators.

  19. Analysis of self-heating of thermally assisted spin-transfer torque magnetic random access memory

    Directory of Open Access Journals (Sweden)

    Austin Deschenes

    2016-11-01

    Full Text Available Thermal assistance has been shown to significantly reduce the required operation power for spin torque transfer magnetic random access memory (STT-MRAM. Proposed heating methods include modified material stack compositions that result in increased self-heating or external heat sources. In this work we analyze the self-heating process of a standard perpendicular magnetic anisotropy STT-MRAM device through numerical simulations in order to understand the relative contributions of Joule, thermoelectric Peltier and Thomson, and tunneling junction heating. A 2D rotationally symmetric numerical model is used to solve the coupled electro-thermal equations including thermoelectric effects and heat absorbed or released at the tunneling junction. We compare self-heating for different common passivation materials, positive and negative electrical current polarity, and different device thermal anchoring and boundaries resistance configurations. The variations considered are found to result in significant differences in maximum temperatures reached. Average increases of 3 K, 10 K, and 100 K for different passivation materials, positive and negative polarity, and different thermal anchoring configurations, respectively, are observed. The highest temperatures, up to 424 K, are obtained for silicon dioxide as the passivation material, positive polarity, and low thermal anchoring with thermal boundary resistance configurations. Interestingly it is also found that due to the tunneling heat, Peltier effect, device geometry, and numerous interfacial layers around the magnetic tunnel junction (MTJ, most of the heat is dissipated on the lower potential side of the magnetic junction. This asymmetry in heating, which has also been observed experimentally, is important as thermally assisted switching requires heating of the free layer specifically and this will be significantly different for the two polarity operations, set and reset.

  20. Nuclear magnetic resonance study of charge transfer complex formation between Silver Nitrate and Benzylcyanide in Solvent Ethylene Glycol

    CERN Document Server

    Modarress, H

    2003-01-01

    The formation constant for charge transfer complexes between electron acceptor (AgNo sub 3) and electron donor benzylcyanide (C sub 6 H sub 5 -CH sub 2 -C ident to N) in solvent ethyleneglycol [(CH sub 2 OH) sub 2] has been evaluated by using the nuclear magnetic resonance chemical shifts of aromatic group of benzylcyanide measured against external references, tetramethylsilane, hexamethyldisilane and cyclohexane at 20 sup d ig sup C. The external referencing procedure eliminated the interference of internal reference in the course of complexation. The necessary bulk magnetic susceptibility corrections on the measured chemical shifts have been made. The solution nationalised and their effects on the formation constant have been considered and a new equation has been suggested to obtain the main ionic activity coefficient of AgNO sub 3 from nuclear magnetic resonance results. The mean ionic activity coefficient has been taken into account in the formation constant calculations. The results indicated that the a...

  1. Design and control strategy applying the novel highly effective magnetic flux coupling (HEMFC) scheme for a non-contact power transfer system

    International Nuclear Information System (INIS)

    Chen, W.-P.; Huang, W.-N.; Chen, P.-S.; Fan, T.-Y.; Chen, M.-P.; Teng, C.-C.

    2006-01-01

    In this paper, the novel design concept for highly effective magnetic flux coupling (HEMFC) schemes, based on enhancement of path guiding effect for leakage flux transmitting, is proposed for a non-contact power transfer system. Two implementation techniques are presented herein utilizing simple structure opinions of specific slant air gap as well as adding of metal bushing components. Both simulation and experimental results demonstrate that the improvement of magnetic coupling ratio and overall system efficiency are achieved by applying the two HEMFC schemes as the power transmitting devices

  2. Accelerating two-dimensional nuclear magnetic resonance correlation spectroscopy via selective coherence transfer

    Science.gov (United States)

    Ye, Qimiao; Chen, Lin; Qiu, Wenqi; Lin, Liangjie; Sun, Huijun; Cai, Shuhui; Wei, Zhiliang; Chen, Zhong

    2017-01-01

    Nuclear magnetic resonance (NMR) spectroscopy serves as an important tool for both qualitative and quantitative analyses of various systems in chemistry, biology, and medicine. However, applications of one-dimensional 1H NMR are often restrained by the presence of severe overlap among different resonances. The advent of two-dimensional (2D) 1H NMR constitutes a promising alternative by extending the crowded resonances into a plane and thereby alleviating the spectral congestions. However, the enhanced ability in discriminating resonances is achieved at the cost of extended experimental duration due to necessity of various scans with progressive delays to construct the indirect dimension. Therefore, in this study, we propose a selective coherence transfer (SECOT) method to accelerate acquisitions of 2D correlation spectroscopy by converting chemical shifts into spatial positions within the effective sample length and then performing an echo planar spectroscopic imaging module to record the spatial and spectral information, which generates 2D correlation spectrum after 2D Fourier transformation. The feasibility and effectiveness of SECOT have been verified by a set of experiments under both homogeneous and inhomogeneous magnetic fields. Moreover, evaluations of SECOT for quantitative analyses are carried out on samples with a series of different concentrations. Based on these experimental results, the SECOT may open important perspectives for fast, accurate, and stable investigations of various chemical systems both qualitatively and quantitatively.

  3. The Study of Fuzzy Proportional Integral Controllers Based on Improved Particle Swarm Optimization for Permanent Magnet Direct Drive Wind Turbine Converters

    Directory of Open Access Journals (Sweden)

    Yancai Xiao

    2016-05-01

    Full Text Available In order to meet the requirements of high precision and fast response of permanent magnet direct drive (PMDD wind turbines, this paper proposes a fuzzy proportional integral (PI controller associated with a new control strategy for wind turbine converters. The purpose of the control strategy is to achieve the global optimization for the quantization factors, ke and kec, and scale factors, kup and kui, of the fuzzy PI controller by an improved particle swarm optimization (PSO method. Thus the advantages of the rapidity of the improved PSO and the robustness of the fuzzy controller can be fully applied in the control process. By conducting simulations for 2 MW PMDD wind turbines with Matlab/Simulink, the performance of the fuzzy PI controller based on the improved PSO is demonstrated to be obviously better than that of the PI controller or the fuzzy PI controller without using the improved PSO under the situation when the wind speed changes suddenly.

  4. Efficient energy transfer and increase of energy density of magnetically charged flywheels

    International Nuclear Information System (INIS)

    Hinterdorfer, T.

    2014-01-01

    Flywheel Energy Storage Systems represent an ecologically and economically sustainable technology for decentralized energy storage. Compared to other storage technologies such as e.g. chemical accumulators, they offer longer life cycles without performance degradation over time and usage and need almost no systematic maintenance. Further, they are made of environmentally friendly materials. By means of the driving torque of an electric motor, the flywheel is accelerated and thus electrical energy is transformed to kinetic energy. The stored energy can be transfered back by the load torque of a generator when needed. Modern flywheel energy storage applications use magnetic bearings to minimize selfdischarge. To avoid bearing forces due to rotor eccentricity an unbalance control strategy is used. However, this leads to an off-centered run of the electric machines rotor which in turn generates undesirable forces. A force-compensating operation of the electric machine will minimize the influence on the magnetic bearings in the planned control scheme, thus increasing their efficiency. Different concepts will be developed and compared to each other by means of simulations. Validation of the simulation models is carried out on a specially constructed test setup under defined conditions. In addition, the electrical machine will be integrated into the concept of redundancy of the flywheel. A bearingless operation increases the reliability and enables a safe shutdown of the application in case of malfunction of the magnetic bearings. High strength composite materials are used to achieve high speeds. Based on existing results from past research activities, a disc-shaped rotor is optimized first. To increase material utilization and to maximize energy density a topology optimization is performed. Evolutionary and gradient based optimization algorithms are used. Thereby the unused strength potential of the material is exploited in order to increase the economic efficiency of

  5. Design of the LINAC4 Transfer Line Quadrupole Electromagnets

    CERN Document Server

    Vanherpe, L

    2013-01-01

    Beam focusing in the various segments of the Linac4 Transfer Line is provided by quadrupole electromagnets. In total seventeen pulsed, air-cooled quadrupole electromagnets are required. They are made of laminated electrical steel yokes and coils wound from solid copper wire. All magnets have an aperture radius of 50 mm and are required to provide an integrated field gradient of 1.8 T over a magnetic length of 300 mm. This design report summarizes the main magnetic, electrical and mechanical design parameters of the Linac4 Transfer Line Quadrupole Magnets. The effect of the vacuum chamber on the magnetic field quality and the field delay is studied.

  6. Measurements of the deuteron and proton magnetic form factors at large momentum transfers

    International Nuclear Information System (INIS)

    Bosted, P.E.; Katramatou, A.T.; Arnold, R.G.; Benton, D.; Clogher, L.; DeChambrier, G.; Lambert, J.; Lung, A.; Petratos, G.G.; Rahbar, A.; Rock, S.E.; Szalata, Z.M.; Debebe, B.; Frodyma, M.; Hicks, R.S.; Hotta, A.; Peterson, G.A.; Gearhart, R.A.; Alster, J.; Lichtenstadt, J.; Dietrich, F.; van Bibber, K.

    1990-01-01

    Measurements of the deuteron elastic magnetic structure function B(Q 2 ) are reported at squared four-momentum transfer values 1.20≤Q 2 ≤2.77 (GeV/c) 2 . Also reported are values for the proton magnetic form factor G Mp (Q 2 ) at 11 Q 2 values between 0.49 and 1.75 (GeV/c) 2 . The data were obtained using an electron beam of 0.5 to 1.3 GeV. Electrons backscattered near 180 degree were detected in coincidence with deuterons or protons recoiling near 0 degree in a large solid-angle double-arm spectrometer system. The data for B(Q 2 ) are found to decrease rapidly from Q 2 =1.2 to 2 (GeV/c) 2 , and then rise to a secondary maximum around Q 2 =2.5 (GeV/c) 2 . Reasonable agreement is found with several different models, including those in the relativistic impulse approximation, nonrelativistic calculations that include meson-exchange currents, isobar configurations, and six-quark configurations, and one calculation based on the Skyrme model. All calculations are very sensitive to the choice of deuteron wave function and nucleon form factor parametrization. The data for G Mp (Q 2 ) are in good agreement with the empirical dipole fit

  7. Symplectic tracking using point magnets in the presence of a longitudinal magnetic field

    International Nuclear Information System (INIS)

    Parzen, G.

    1993-09-01

    In the absence of a longitudinal magnetic field, symplectic tracking can be achieved by replacing the magnets by a series of point magnets and drift spaces. To treat the case when a longitudinal magnetic field is also present, this procedure is modified in this paper by replacing the drift space by a solenoidal drift, which is defined as the motion of a particle in a uniform longitudinal magnetic field. A symplectic integrator can be obtained by subdividing each magnet into pieces and replacing each magnet piece by point magnets, with only transverse fields, and solenoidal drift spaces. The reference orbit used here is made up of arcs of circles and straight lines which join smoothly with each other. For this choice of reference orbit, the required results are obtained to track particles, which are the transfer functions, and the transfer time for the different elements. It is shown that these results provide a symplectic integrator, and they are exact in the sense that as the number of magnet pieces is increased, the particle motion will converge to the particle motion of the exact equations of motion

  8. Magnetization transfer analysis of cartilage repair tissue: a preliminary study

    International Nuclear Information System (INIS)

    Palmieri, F.; Keyzer, F. de; Maes, F.; Breuseghem, I. van

    2006-01-01

    To evaluate the magnetization transfer ratio (MTR) after two different cartilage repair procedures, and to compare these data with the MTR of normal cartilage. Twenty-seven patients with a proven cartilage defect were recruited: 13 were treated with autologous chondrocyte implantation (ACI) and 14 were treated with the microfracture technique (MFR). All patients underwent MRI examinations with MT-sequences before the surgical treatment, after 12 months (26 patients) and after 24 months (11 patients). Eleven patients received a complete follow-up study at all three time points (five of the ACI group and six of the MFR group). All images were transferred to a workstation to calculate MTR images. For every MT image set, different ROIs were delineated by two radiologists. Means were calculated per ROI type in the different time frames and in both groups of cartilage repair. The data were analyzed with unpaired t- and ANOVA tests, and by calculating Pearson's correlation coefficient. No significant differences were found in the MTR of fatty bone marrow, muscle and normal cartilage in the different time frames. There was a significant but small difference between the MTR of normal cartilage and the cartilage repair area after 12 months for both procedures. After 24 months, the MTR of ACI repaired cartilage (0.31±0.07) was not significantly different from normal cartilage MTR (0.34±0.05). The MTR of MFR repaired cartilage (0.28±0.02), still showed a significant difference from normal cartilage. The differences between damaged and repaired cartilage MTR are too small to enable MT-imaging to be a useful tool for postoperative follow-up of cartilage repair procedures. There is, however, an evolution towards normal MTR-values in the cartilage repair tissue (especially after ACI repair). (orig.)

  9. Strong Magnetic Field Characterisation

    Science.gov (United States)

    2012-04-01

    an advertised surface field of approximately 0.5 T were used to supply the static magnetic field source. The disc magnet had a diameter of 50 mm and... colour bar indicates the magnetic field strength set to an arbitrary 0.25 T. The white area has a field >0.25 T. The size of the arrow is proportional...9 shows the magnetic field strength along a slice in the XZ plane. The colours represent the total UNCLASSIFIED 10 UNCLASSIFIED DSTO-TR-2699

  10. Numerical simulation of magnetic convection ferrofluid flow in a permanent magnet-inserted cavity

    Science.gov (United States)

    Ashouri, Majid; Behshad Shafii, Mohammad

    2017-11-01

    The magnetic convection heat transfer in an obstructed two-dimensional square cavity is investigated numerically. The walls of the cavity are heated with different constant temperatures at two sides, and isolated at two other sides. The cavity is filled with a high Prandtl number ferrofluid. The convective force is induced by a magnetic field gradient of a thermally insulated square permanent magnet located at the center of the cavity. The results are presented in the forms of streamlines, isotherms, and Nusselt number for various values of magnetic Rayleigh numbers and permanent magnet size. Two major circulations are generated in the cavity, clockwise flow in the upper half and counterclockwise in the lower half. In addition, strong circulations are observed around the edges of the permanent magnet surface. The strength of the circulations increase monotonically with the magnetic Rayleigh number. The circulations also increase with the permanent magnet size, but eventually, are suppressed for larger sizes. It is found that there is an optimum size for the permanent magnet due to the contrary effects of the increase in magnetic force and the increase in flow resistance by increasing the size. By increasing the magnetic Rayleigh number or isothermal walls temperature ratio, the heat transfer rate increases.

  11. Numerical analysis of the shifting slabs applied in a wireless power transfer system to enhance magnetic coupling

    Directory of Open Access Journals (Sweden)

    Yayun Dong

    2017-05-01

    Full Text Available Shifting medium is a kind of metamaterial, which can optically shift a space or an object a certain distance away from its original position. Based on the shifting medium, we propose a concise pair of shifting slabs covering the transmitting or receiving coil in a two-coil wireless power transfer system to decrease the equivalent distance between the coils. The electromagnetic parameters of the shifting slabs are calculated by transformation optics. Numerical simulations validate that the shifting slabs can approximately shift the electromagnetic fields generated by the covered coil; thus, the magnetic coupling and the efficiency of the system are enhanced while remaining the physical transmission distance unchanged. We also verify the advantages of the shifting slabs over the magnetic superlens. Finally, we provide two methods to fabricate shifting slabs based on split-ring resonators.

  12. Probing the Magnetic Field Structure in Sgr A* on Black Hole Horizon Scales with Polarized Radiative Transfer Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Gold, Roman; McKinney, Jonathan C. [Department of Physics and Joint Space-Science Institute, University of Maryland, College Park, MD 20742 (United States); Johnson, Michael D.; Doeleman, Sheperd S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2017-03-10

    Magnetic fields are believed to drive accretion and relativistic jets in black hole accretion systems, but the magnetic field structure that controls these phenomena remains uncertain. We perform general relativistic (GR) polarized radiative transfer of time-dependent three-dimensional GR magnetohydrodynamical simulations to model thermal synchrotron emission from the Galactic Center source Sagittarius A* (Sgr A*). We compare our results to new polarimetry measurements by the Event Horizon Telescope (EHT) and show how polarization in the visibility (Fourier) domain distinguishes and constrains accretion flow models with different magnetic field structures. These include models with small-scale fields in disks driven by the magnetorotational instability as well as models with large-scale ordered fields in magnetically arrested disks. We also consider different electron temperature and jet mass-loading prescriptions that control the brightness of the disk, funnel-wall jet, and Blandford–Znajek-driven funnel jet. Our comparisons between the simulations and observations favor models with ordered magnetic fields near the black hole event horizon in Sgr A*, though both disk- and jet-dominated emission can satisfactorily explain most of the current EHT data. We also discuss how the black hole shadow can be filled-in by jet emission or mimicked by the absence of funnel jet emission. We show that stronger model constraints should be possible with upcoming circular polarization and higher frequency (349 GHz) measurements.

  13. Isotopic effect on the quantum tunneling of the magnetization of molecular nanomagnets

    International Nuclear Information System (INIS)

    Sessoli, Roberta; Caneschi, Andrea; Gatteschi, Dante; Sorace, Lorenzo; Cornia, Andrea; Wernsdorfer, Wolfgang

    2001-01-01

    The molecular cluster [Fe 8 (tacn) 6 O 2 (OH) 12 ]Br 8 ·9H 2 O, Fe 8 , characterized by S=10, with biaxial magnetic anisotropy is an ideal system to investigate quantum effects in the dynamics of the magnetization. Resonant quantum tunneling gives rise to stepped hysteresis cycles and below 0.35 K pure quantum tunneling of the magnetization has been observed. The role of hyperfine fields in promoting the tunneling as a source of dynamic broadening of the states involved in the tunnel transition is investigated by preparing and characterizing two isotopically enriched samples using 57 Fe and 2 H. The relaxation rate in the tunneling regime is proportional to the hyperfine field generated by the nuclei. Also, the intrinsic linewidth of the tunneling resonance scales with the hyperfine field as confirmed by calculations of the super (or transfer) and direct hyperfine interactions. Preliminary results on a novel cluster of formula [Fe 4 (OCH 3 ) 6 (dpm) 6 ], Fe 4 , suited for a more dramatic isotope effect on the tunneling rate are also reported

  14. A magnetic tunnel to shelter hyperpolarized fluids

    International Nuclear Information System (INIS)

    Milani, Jonas; Vuichoud, Basile; Bornet, Aurélien; Miéville, Pascal; Mottier, Roger; Jannin, Sami; Bodenhausen, Geoffrey

    2015-01-01

    To shield solutions carrying hyperpolarized nuclear magnetization from rapid relaxation during transfer through low fields, the transfer duct can be threaded through an array of permanent magnets. The advantages are illustrated for solutions containing hyperpolarized 1 H and 13 C nuclei in a variety of molecules

  15. Insights into Dynamic Tuning of Magnetic-Resonant Wireless Power Transfer Receivers Based on Switch-Mode Gyrators

    Directory of Open Access Journals (Sweden)

    Mohamed Saad

    2018-02-01

    Full Text Available Magnetic-resonant wireless power transfer (WPT has become a reliable contactless source of power for a wide range of applications. WPT spans different power levels ranging from low-power implantable devices up to high-power electric vehicles (EV battery charging. The transmission range and efficiency of WPT have been reasonably enhanced by resonating the transmitter and receiver coils at a common frequency. Nevertheless, matching between resonance in the transmitter and receiver is quite cumbersome, particularly in single-transmitter multi-receiver systems. The resonance frequency in transmitter and receiver tank circuits has to be perfectly matched, otherwise power transfer capability is greatly degraded. This paper discusses the mistuning effect of parallel-compensated receivers, and thereof a novel dynamic frequency tuning method and related circuit topology and control is proposed and characterized in the system application. The proposed method is based on the concept of switch-mode gyrator emulating variable lossless inductors oriented to enable self-tunability in WPT receivers.

  16. Lattice Boltzmann simulation of natural convection heat transfer in an open enclosure filled with Cu–water nanofluid in a presence of magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Ahmed Kadhim, E-mail: ahmedkadhim7474@gmail.com [Department of Mechanical Engineering, College of Engineering, Babylon University, Babylon City (Iraq); Ashorynejad, Hamid Reza; Shikholeslami, Mohsen [Faculty of Mechanical Engineering, Babol University of Technology, Babol, Mazandaran, Islamic Republic of Iran (Iran, Islamic Republic of); Sivasankaran, S. [Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur 50603 (Malaysia)

    2014-03-15

    Highlights: • Convection very strong when Ra is high and Ha = 0. • Isotherms smooth when Ra is low and Ha is high. • Maximum stream function increases by adding nano-particle. • Flow circulation decreases when magnetic orientation angle increases. • Nusselt number ratio increases when Ra increases. - Abstract: In this paper magneto hydrodynamic (MHD) natural convection flow of Cu–water nanofluid in an open enclosure is investigated numerically using lattice Boltzmann method (LBM) scheme. The effective thermal conductivity and viscosity of nanofluid are calculated by the Maxwell–Garnetts (MG) and Brinkman models, respectively. In addition, the MDF model was used for simulating the effect of uniform magnetic field. The influence of pertinent parameters such as Hartmann number, nanoparticle volume fraction, Rayleigh number and the inclination of magnetic field on the flow and heat transfer characteristics have been examined. The results indicate that the absolute values of stream function decline significantly by increasing Hartmann numbers while these values rise by increasing Rayleigh numbers. Moreover, the results show that the solid volume fraction has a significant influence on stream function and heat transfer, depending on the value of Hartmann and Rayleigh numbers.

  17. Deterministic Generation of Quantum State Transfer Between Spatially Separated Single Molecule Magnets

    International Nuclear Information System (INIS)

    Song Peijun; Lue Xinyou; Huang Pei; Hao Xiangying; Yang Xiaoxue

    2010-01-01

    We propose a new scheme for realizing deterministic quantum state transfer (QST) between two spatially separated single molecule magnets (SMMs) with the framework of cavity quantum electrodynamics (QED). In the present scheme, two SMMs are trapped in two spatially separated optical cavities coupled by an optical fiber. Through strictly numerically simulating, we demonstrate that our scheme is robust with respect to the SMMs' spontaneous decay and fiber loss under the conditions of dispersive SMMs-field interaction and strong coupling of cavity fiber. In addition, we also discuss the influence of photon leakage out of cavities and show that our proposal is good enough to demonstrate the generation of QST with high fidelity utilizing the current experimental technology. The present investigation provides research opportunities for realizing QST between solid-state qubits and may result in a substantial impact on the progress of solid-state-based quantum communications network. (general)

  18. Magnetization transfer contrast on gradient echo MR imaging of the temporomandibular joint

    International Nuclear Information System (INIS)

    Niitsu, M.; Hirohata, H.; Yoshioka, H.; Anno, I.; Campeau, N.G.; Itai, Y.

    1995-01-01

    Thirty-nine temporomandibular joints (TMJ) from 20 patients with suspected internal derangements were imaged by a 1.5 T MR imager. The on-resonance binomial magnetization transfer contrast (MTC) pulse was applied to gradient echo images with a dual receiver coil (9 s/section). With the use of an opening device, a series of sequential images were obtained at increments of mouth opening and closing. The tissue signal intensities with (Ms) and without (Mo) MTC were measured and subjective image analysis was performed. Compared with the standard images, MTC technique provided selective signal suppression of disks. The average of Ms/Mo ratio of the disks (0.56) was lower than that of the retrodiskal pad (0.79) and of the effusion (0.89). With MTC technique, fluid conspicuity was superior to standard image. However, no significant superiority was found in disk definition subjectively. (orig.)

  19. Magnetoresistance and magnetic breakdown phenomenon in amorphous magnetic alloys

    International Nuclear Information System (INIS)

    Chen Hui-yu; Gong Xiao-yu

    1988-01-01

    Transverse magnetoresistance in amorphous magnetic alloys (Fe/sub 1-//sub x/CO/sub x/) 82 Cu/sub 0.4/Si/sub 4.4/B/sub 13.2/ were measured at room temperature and in the magnetic field range 0--15 kOe. For large magnetic field, three different functional dependences of magnetoresistance on magnetic field strength have been found as follows: (1) Δrho/rho approaches saturation. (2) Δrho/rho increases proportionally to H 2 . (3) For x = 0.15, a sharp Δrho/rho peak appears at a certain magnetic field strength in spatial angular orientation of both magnetic field and electric currents. Case (3) is a magnetic breakdown phenomenon. Magnetic breakdown occurs at the gap between the spin-up and spin-down sheets of the Fermi surface. This gap is the spin-orbit gap and its magnitude is a sensitive function of magnetization. Hence the magnitude and width of the magnetoresistance peak and the magnetic field strength at the peak point are functions of angular orientation of both magnetic field and electric current

  20. Numerical transfer-matrix study of a model with competing metastable states

    DEFF Research Database (Denmark)

    Fiig, T.; Gorman, B.M.; Rikvold, P.A.

    1994-01-01

    transition. A recently developed transfer-matrix formalism is applied to the model to obtain complex-valued ''constrained'' free-energy densities f(alpha). For particular eigenvectors of the transfer matrix, the f(alpha) exhibit finite-rangescaling behavior in agreement with the analytically continued...... 'metastable free-energy density This transfer-matrix approach gives a free-energy cost of nucleation that supports the proportionality relation for the decay rate of the metastable phase T proportional to\\Imf alpha\\, even in cases where two metastable states compete. The picture that emerges from this study...

  1. A magnetic tunnel to shelter hyperpolarized fluids

    Energy Technology Data Exchange (ETDEWEB)

    Milani, Jonas, E-mail: jonas.milani@epfl.ch; Vuichoud, Basile; Bornet, Aurélien; Miéville, Pascal; Mottier, Roger [Institut des Sciences et Ingénierie Chimiques, Ecole Polytechnique Fédérale de Lausanne (EPFL), Batochime, CH-1015 Lausanne (Switzerland); Jannin, Sami [Institut des Sciences et Ingénierie Chimiques, Ecole Polytechnique Fédérale de Lausanne (EPFL), Batochime, CH-1015 Lausanne (Switzerland); Bruker BioSpin AG, Industriestrasse 26, CH-8117 Fällanden (Switzerland); Bodenhausen, Geoffrey [Institut des Sciences et Ingénierie Chimiques, Ecole Polytechnique Fédérale de Lausanne (EPFL), Batochime, CH-1015 Lausanne (Switzerland); Département de Chimie, École Normale Supérieure-PSL Research University, 24 rue Lhomond, F-75005 Paris (France); Sorbonne Universités, UPMC Univ Paris 06, LBM, 4 place Jussieu, F-75005 Paris (France); CNRS, UMR 7203 LBM, F-75005 Paris (France)

    2015-02-15

    To shield solutions carrying hyperpolarized nuclear magnetization from rapid relaxation during transfer through low fields, the transfer duct can be threaded through an array of permanent magnets. The advantages are illustrated for solutions containing hyperpolarized {sup 1}H and {sup 13}C nuclei in a variety of molecules.

  2. Characteristics simulation of wireless power transfer system considering shielding distance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu Kyeong; Choi, Hyo Sang; Jung, Byung Ik; Jeong, In Sung [Chosun University, Gwangju (Korea, Republic of)

    2015-03-15

    Wireless power transfer technology is using the magnetic resonance recently drawing increased attention. It uses the resonance between transmitter and receiver coils to transfer power. Thus, it can improve the transfer distance and efficiency compared with the existing magnetic induction technique. The authors found from the previous study that the application of the superconductor coil to the magnetic resonance wireless power transfer system improved its efficiency. Its application to real life, however, requires the additional study on the effects of adjacent materials. In this study, the two resonance coils made by superconductor coils were used to aluminum and plastic shielding materials was placed between the coils. S-parameters were analyzed according to the position of the shielding material between the transmitter and receiver coils. As a result, the plastic of shielding material had no effect, but the aluminum of shielding material affected the wireless power transfer due to the shielding effectiveness.

  3. Characteristics simulation of wireless power transfer system considering shielding distance

    International Nuclear Information System (INIS)

    Lee, Yu Kyeong; Choi, Hyo Sang; Jung, Byung Ik; Jeong, In Sung

    2015-01-01

    Wireless power transfer technology is using the magnetic resonance recently drawing increased attention. It uses the resonance between transmitter and receiver coils to transfer power. Thus, it can improve the transfer distance and efficiency compared with the existing magnetic induction technique. The authors found from the previous study that the application of the superconductor coil to the magnetic resonance wireless power transfer system improved its efficiency. Its application to real life, however, requires the additional study on the effects of adjacent materials. In this study, the two resonance coils made by superconductor coils were used to aluminum and plastic shielding materials was placed between the coils. S-parameters were analyzed according to the position of the shielding material between the transmitter and receiver coils. As a result, the plastic of shielding material had no effect, but the aluminum of shielding material affected the wireless power transfer due to the shielding effectiveness

  4. Design and characterization of a device to quantify the magnetic drug targeting efficiency of magnetic nanoparticles in a tube flow phantom by magnetic particle spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Radon, Patricia, E-mail: patricia.radon@ptb.de; Löwa, Norbert; Gutkelch, Dirk; Wiekhorst, Frank

    2017-04-01

    The aim of magnetic drug targeting (MDT) is to transfer a therapeutic drug coupled to magnetic nanoparticles (MNP) to desired disease locations (e.g. tumor region) with the help of magnetic field gradients. To transfer the MDT approach into clinical practice a number of important issues remain to be solved. We developed and characterized an in-vitro flow phantom to provide a defined and reproducible MDT environment. The tube system of the flow phantom is directed through the detection coil of a magnetic particle spectroscopy (MPS) device to determine the targeting efficiency. MPS offers an excellent temporal resolution of seconds and an outstanding specific sensitivity of some nanograms of iron. In the flow phantom different MNP types, magnet geometries and tube materials can be employed to vary physical parameters like diameter, flow rate, magnetic targeting gradient, and MNP properties. - Highlights: • Flow phantom for magnetic targeting. • MPS for quantitative MNP detection. • ng detection limit for MNP.

  5. Excavating a transfer tunnel

    CERN Multimedia

    Laurent Guiraud

    2000-01-01

    The transfer tunnel being dug here will take the 450 GeV beam from the SPS and inject it into the LHC where the beam energies will be increased to 7 TeV. In order to transfer this beam from the SPS to the LHC, two transfer tunnels are used to circulate the beams in opposite directions. When excavated, the accelerator components, including magnets, beam pipes and cryogenics will be installed and connected to both the SPS and LHC ready for operation to begin in 2008.

  6. Interface-Induced Phenomena in Magnetism.

    Science.gov (United States)

    Hellman, Frances; Hoffmann, Axel; Tserkovnyak, Yaroslav; Beach, Geoffrey S D; Fullerton, Eric E; Leighton, Chris; MacDonald, Allan H; Ralph, Daniel C; Arena, Dario A; Dürr, Hermann A; Fischer, Peter; Grollier, Julie; Heremans, Joseph P; Jungwirth, Tomas; Kimel, Alexey V; Koopmans, Bert; Krivorotov, Ilya N; May, Steven J; Petford-Long, Amanda K; Rondinelli, James M; Samarth, Nitin; Schuller, Ivan K; Slavin, Andrei N; Stiles, Mark D; Tchernyshyov, Oleg; Thiaville, André; Zink, Barry L

    2017-01-01

    This article reviews static and dynamic interfacial effects in magnetism, focusing on interfacially-driven magnetic effects and phenomena associated with spin-orbit coupling and intrinsic symmetry breaking at interfaces. It provides a historical background and literature survey, but focuses on recent progress, identifying the most exciting new scientific results and pointing to promising future research directions. It starts with an introduction and overview of how basic magnetic properties are affected by interfaces, then turns to a discussion of charge and spin transport through and near interfaces and how these can be used to control the properties of the magnetic layer. Important concepts include spin accumulation, spin currents, spin transfer torque, and spin pumping. An overview is provided to the current state of knowledge and existing review literature on interfacial effects such as exchange bias, exchange spring magnets, spin Hall effect, oxide heterostructures, and topological insulators. The article highlights recent discoveries of interface-induced magnetism and non-collinear spin textures, non-linear dynamics including spin torque transfer and magnetization reversal induced by interfaces, and interfacial effects in ultrafast magnetization processes.

  7. Design, fabrication, and calibration of curved integral coils for measuring transfer function, uniformity, and effective length of LBL ALS [Lawrence Berkeley Laboratory Advanced Light Source] Booster Dipole Magnets

    International Nuclear Information System (INIS)

    Green, M.I.; Nelson, D.; Marks, S.; Gee, B.; Wong, W.; Meneghetti, J.

    1989-03-01

    A matched pair of curved integral coils has been designed, fabricated and calibrated at Lawrence Berkeley Laboratory for measuring Advanced Light Source (ALS) Booster Dipole Magnets. Distinctive fabrication and calibration techniques are described. The use of multifilar magnet wire in fabrication integral search coils is described. Procedures used and results of AC and DC measurements of transfer function, effective length and uniformity of the prototype booster dipole magnet are presented in companion papers. 8 refs

  8. Analysis and optimization of coupled windings in magnetic resonant wireless power transfer systems with orthogonal experiment method

    DEFF Research Database (Denmark)

    Yudi, Xiao; Xingkui, Mao; Mao, Lin

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual...... inductance model. Then the design method with orthogonal experiments and finite element method simulation is proposed to maximize the kQ due to low precise analytical model of AC resistance and inductance for PCB windings at high- frequency. The method can reduce the design iterations and thereby can get...... more optimal design results. The experiments verified the design objective of kQ as well as the design method effectively. In the optimal PCB windings prototype at operating frequency of 4 MHz, the kQ and the maximum efficiency are increased by about 12% and 4% respectively....

  9. Analysis and optimisation of coupled winding in magnetic resonant wireless power transfer systems with orthogonal experiment results

    DEFF Research Database (Denmark)

    Yudi, Xiao; Xingkui, Mao; Mao, Lin

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual...... inductance model. Then the design method with orthogonal experiments and finite element method simulation is proposed to maximize the kQ due to low precise analytical model of AC resistance and inductance for PCB windings at high- frequency. The method can reduce the design iterations and thereby can get...... more optimal design results. The experiments verified the design objective of kQ as well as the design method effectively. In the optimal PCB windings prototype at operating frequency of 4 MHz, the kQ and the maximum efficiency are increased by about 12% and 4% respectively....

  10. Heat transfer and entropy generation analysis of hybrid graphene/Fe3O4 ferro-nanofluid flow under the influence of a magnetic field

    DEFF Research Database (Denmark)

    Mehrali, Mohammad; Sadeghinezhad, Emad; Akhiani, Amir Reza

    2017-01-01

    oxide, iron salts and tannic acid as the reductant and stabilizer. The thermophysical and magnetic properties of the hybrid nanofluid have been widely characterized and thermal conductivity has shown an enhancement of 11%. The experimental results indicated that the heat transfer enhancement of hybrid...

  11. Quantitative magnetization transfer imaging of rodent glioma using selective inversion recovery.

    Science.gov (United States)

    Xu, Junzhong; Li, Ke; Zu, Zhongliang; Li, Xia; Gochberg, Daniel F; Gore, John C

    2014-03-01

    Magnetization transfer (MT) provides an indirect means to detect noninvasively variations in macromolecular contents in biological tissues, but, so far, there have been only a few quantitative MT (qMT) studies reported in cancer, all of which used off-resonance pulsed saturation methods. This article describes the first implementation of a different qMT approach, selective inversion recovery (SIR), for the characterization of tumor in vivo using a rodent glioma model. The SIR method is an on-resonance method capable of fitting qMT parameters and T1 relaxation time simultaneously without mapping B0 and B1 , which is very suitable for high-field qMT measurements because of the lower saturation absorption rate. The results show that the average pool size ratio (PSR, the macromolecular pool versus the free water pool) in rat 9 L glioma (5.7%) is significantly lower than that in normal rat gray matter (9.2%) and white matter (17.4%), which suggests that PSR is potentially a sensitive imaging biomarker for the assessment of brain tumor. Despite being less robust, the estimated MT exchange rates also show clear differences from normal tissues (19.7 Hz for tumors versus 14.8 and 10.2 Hz for gray and white mater, respectively). In addition, the influence of confounding effects, e.g. B1 inhomogeneity, on qMT parameter estimates is investigated with numerical simulations. These findings not only help to better understand the changes in the macromolecular contents of tumors, but are also important for the interpretation of other imaging contrasts, such as chemical exchange saturation transfer of tumors. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Transfer to hospital in planned home births

    DEFF Research Database (Denmark)

    Blix, Ellen; Kumle, Merethe; Kjærgaard, Hanne

    2014-01-01

    was chosen. RESULTS: Fifteen studies were eligible for inclusion, containing data from 215,257 women. The total proportion of transfer from home to hospital varied from 9.9% to 31.9% across the studies. The most common indication for transfer was labour dystocia, occurring in 5.1% to 9.8% of all women...

  13. Application of Laplace transform for the exact effect of a magnetic field on heat transfer of carbon nanotubes-suspended nanofluids

    Energy Technology Data Exchange (ETDEWEB)

    Ebaid, Abdelhalim; Al Sharif, Mohammed A. [Tabuk Univ. (Saudi Arabia). Faculty of Science

    2015-10-01

    Since the discovery of the carbon nanotubes (CNTs), there is an increasing interest in their applications in industry and medical fields. Attempts of using such CNTs as drug carriers and in cancer therapy in the presence of a magnetic field are now undertaken because of their direct impacts on increasing the thermal conductivity of base fluids. Two types of CNTs are well known for the researchers, the single-walled CNT (SWCNTs) and the multi-walled CNTs (MWCNTs); however, the subject of which one is more effective in treatment of cancer deserves more investigations. The present article discusses the effect of such types of CNTs on the flow and heat transfer of nanofluids in the presence of a magnetic field. Exact analytical solution for the heat equation has been obtained by using the Laplace transform, where the solution is expressed in terms of a new special function, the generalised incomplete gamma function. The effects of various parameters on the fluid velocity, temperature distribution, and heat transfer rates have been introduced. Details of possible applications of the current results in the treatment of cancer have been also discussed.

  14. Application of Laplace transform for the exact effect of a magnetic field on heat transfer of carbon nanotubes-suspended nanofluids

    International Nuclear Information System (INIS)

    Ebaid, Abdelhalim; Al Sharif, Mohammed A.

    2015-01-01

    Since the discovery of the carbon nanotubes (CNTs), there is an increasing interest in their applications in industry and medical fields. Attempts of using such CNTs as drug carriers and in cancer therapy in the presence of a magnetic field are now undertaken because of their direct impacts on increasing the thermal conductivity of base fluids. Two types of CNTs are well known for the researchers, the single-walled CNT (SWCNTs) and the multi-walled CNTs (MWCNTs); however, the subject of which one is more effective in treatment of cancer deserves more investigations. The present article discusses the effect of such types of CNTs on the flow and heat transfer of nanofluids in the presence of a magnetic field. Exact analytical solution for the heat equation has been obtained by using the Laplace transform, where the solution is expressed in terms of a new special function, the generalised incomplete gamma function. The effects of various parameters on the fluid velocity, temperature distribution, and heat transfer rates have been introduced. Details of possible applications of the current results in the treatment of cancer have been also discussed.

  15. Numerical analysis of thermally actuated magnets for magnetization of superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Li Quan; Yan Yu; Rawlings, Colin; Coombs, Tim, E-mail: ql229@cam.ac.u [EPEC Superconductivity Group, Engineering Department, University of Cambridge, Trumpington Street. Cambridge, CB2 1PZ (United Kingdom)

    2010-06-01

    Superconductors, such as YBCO bulks, have extremely high potential magnetic flux densities, comparing to rare earth magnets. Therefore, the magnetization of superconductors has attracted broad attention and contribution from both academic research and industry. In this paper, a novel technique is proposed to magnetize superconductors. Unusually, instead of using high magnetic fields and pulses, repeatedly magnetic waves with strength of as low as rare earth magnets are applied. These magnetic waves, generated by thermally controlling a Gadolinium (Gd) bulk with a rare earth magnet underneath, travel over the flat surface of a YBCO bulk and get trapped little by little. Thus, a very small magnetic field can be used to build up a very large magnetic field. In this paper, the modelling results of thermally actuated magnetic waves are presented showing how to transfer sequentially applied thermal pulses into magnetic waves. The experiment results of the magnetization of YBCO bulk are also presented to demonstrate how superconductors are progressively magnetized by small magnetic field

  16. Numerical analysis of thermally actuated magnets for magnetization of superconductors

    International Nuclear Information System (INIS)

    Li Quan; Yan Yu; Rawlings, Colin; Coombs, Tim

    2010-01-01

    Superconductors, such as YBCO bulks, have extremely high potential magnetic flux densities, comparing to rare earth magnets. Therefore, the magnetization of superconductors has attracted broad attention and contribution from both academic research and industry. In this paper, a novel technique is proposed to magnetize superconductors. Unusually, instead of using high magnetic fields and pulses, repeatedly magnetic waves with strength of as low as rare earth magnets are applied. These magnetic waves, generated by thermally controlling a Gadolinium (Gd) bulk with a rare earth magnet underneath, travel over the flat surface of a YBCO bulk and get trapped little by little. Thus, a very small magnetic field can be used to build up a very large magnetic field. In this paper, the modelling results of thermally actuated magnetic waves are presented showing how to transfer sequentially applied thermal pulses into magnetic waves. The experiment results of the magnetization of YBCO bulk are also presented to demonstrate how superconductors are progressively magnetized by small magnetic field

  17. Magnetic flux conversion and relaxation toward a minimum-energy state in S-1 spheromak plasmas

    International Nuclear Information System (INIS)

    Janos, A.

    1985-09-01

    S-1 Spheromak currents and magnetic fluxes have been measured with Rogowski coils and flux loops external to the plasma. Toroidal plasma currents up to 350 kA and spheromak configuration lifetimes over 1.0 msec have been achieved at moderate power levels. The plasma formation in the S-1 Spheromak device is based on an inductive transfer of poloidal and toroidal magnetic flux from a toroidal ''flux core'' to the plasma. Formation is programmed to guide the configuration into a force-free, minimum-energy Taylor state. Properly detailed programming of the formation process is found not to be essential since plasmas adjust themselves during formation to a final equilibrium near the Taylor state. After formation, if the plasma evolves away from the stable state, then distinct relaxation oscillation events occur which restore the configuration to that stable state. The relaxation process involves reconnection of magnetic field lines, and conversion of poloidal to toroidal magnetic flux (and vice versa) has been observed and documented. The scaling of toroidal plasma current and toroidal magnetic flux in the plasma with externally applied currents is consistent with the establishment of a Taylor state after formation. In addition, the magnetic helicity is proportional to that injected from the flux core, independent of how that helicity is generated

  18. Magnetic flux concentration methods for magnetic energy harvesting module

    Directory of Open Access Journals (Sweden)

    Wakiwaka Hiroyuki

    2013-01-01

    Full Text Available This paper presents magnetic flux concentration methods for magnetic energy harvesting module. The purpose of this study is to harvest 1 mW energy with a Brooks coil 2 cm in diameter from environmental magnetic field at 60 Hz. Because the harvesting power is proportional to the square of the magnetic flux density, we consider the use of a magnetic flux concentration coil and a magnetic core. The magnetic flux concentration coil consists of an air­core Brooks coil and a resonant capacitor. When a uniform magnetic field crossed the coil, the magnetic flux distribution around the coil was changed. It is found that the magnetic field in an area is concentrated larger than 20 times compared with the uniform magnetic field. Compared with the air­core coil, our designed magnetic core makes the harvested energy ten­fold. According to ICNIRP2010 guideline, the acceptable level of magnetic field is 0.2 mT in the frequency range between 25 Hz and 400 Hz. Without the two magnetic flux concentration methods, the corresponding energy is limited to 1 µW. In contrast, our experimental results successfully demonstrate energy harvesting of 1 mW from a magnetic field of 0.03 mT at 60 Hz.

  19. Proportionality for Military Leaders

    National Research Council Canada - National Science Library

    Brown, Gary D

    2000-01-01

    .... Especially lacking is a realization that there are four distinct types of proportionality. In determining whether a particular resort to war is just, national leaders must consider the proportionality of the conflict (i.e...

  20. Investigating the efficacy of magnetic nanofluid as a coolant in double-pipe heat exchanger in the presence of magnetic field

    International Nuclear Information System (INIS)

    Bahiraei, Mehdi; Hangi, Morteza

    2013-01-01

    Highlights: • Efficacy of magnetic nanofluid as coolant was studied in double-pipe heat exchanger. • Effect of applying quadrupole magnetic field with different magnitudes was analyzed. • Magnetic force makes the concentration distribution more uniform in tube side. • Applying magnetic field enhances both pressure drop and heat transfer. • Optimization was performed to reach maximum heat transfer and minimum pressure drop. - Abstract: The current study attempts to investigate the performance of water based Mn–Zn ferrite magnetic nanofluid in a counter-flow double-pipe heat exchanger under quadrupole magnetic field using the two-phase Euler–Lagrange method. The nanofluid flows in the tube side as coolant, while the hot water flows in the annulus side. The effects of different parameters including concentration, size of the particles, magnitude of the magnetic field and Reynolds number are examined. Distribution of the particles is non-uniform at the cross section of the tube such that the concentration is higher at central regions of the tube. Application of the magnetic field makes the distribution of particles more uniform and this uniformity increases by increasing the distance from the tube inlet. Increasing each of the parameters of concentration, particle size and magnitude of the magnetic field will lead to a greater pressure drop and also higher heat transfer improvement. At higher Reynolds numbers, the effect of magnetic force is diminished. Optimization was performed using genetic algorithm coupled with compromise programming technique in order to reach the maximum overall heat transfer coefficient along with the minimum pressure drop. For this purpose, the models of objective functions of overall heat transfer coefficient and pressure drop of the nanofluid were first extracted in terms of the effective parameters using neural network. The neural network model predicts the output variables with a very good accuracy. The optimal values were

  1. Interfacing a gas proportional counter with a mass spectrometer: Simultaneous display of GC/MS and radiocarbon data

    International Nuclear Information System (INIS)

    Peterson, G.S.; Laemmerhirt, D.F.; Weaver, A.

    1985-01-01

    To facilitate the location of pesticides and monitor their metabolism in environmental and biological systems, carbon-14 labelling of the parent compound is used. Detection of the radiolabel is achieved using a gas proportional counter, while identification of the labelled components is most easily accomplished with mass spectrometry. However, when these two operations are performed separately, correlation of the information is awkward, at best. Since each is a destructive detector, simultaneous monitoring of the outposts requires an effluent splitter. The complete system consists of a variable splitter, which allows control of the ratio of the GC effluent to the two instruments, and signal processing circuitry for simultaneous recording and storage of radiocarbon and mass spectral data. Modifications to a Finnigan GC/MS and Gas Proportional Counter included a high temperature GC effluent splitter with glass-lined connecting tubing, and a data interface, including analog to digital and serial to parallel conversions with optical isolation between the gas proportional counter and the computer. The splitter restricted the flow to the mass spectrometer, preventing flow completely in the closed position. The split was adjusted to maximize flow to the mass spectrometer using the vacuum as a rough guide (1.0 x 10 -5 torr in EI, 7.5 x 10 -5 torr in CI). A heated transfer line between the transfer oven and gas proportional counter prevented condensation of eluting components prior to radiocarbon detection

  2. Transfer to hospital in planned home births: a systematic review.

    Science.gov (United States)

    Blix, Ellen; Kumle, Merethe; Kjærgaard, Hanne; Øian, Pål; Lindgren, Helena E

    2014-05-29

    There is concern about the safety of homebirths, especially in women transferred to hospital during or after labour. The scope of transfer in planned home births has not been assessed in a systematic review. This review aimed to describe the proportions and indications for transfer from home to hospital during or after labour in planned home births. The databases Pubmed, Embase, Cinahl, Svemed+, and the Cochrane Library were searched using the MeSH term "home childbirth". Inclusion criteria were as follows: the study population was women who chose planned home birth at the onset of labour; the studies were from Western countries; the birth attendant was an authorised midwife or medical doctor; the studies were published in 1985 or later, with data not older than from 1980; and data on transfer from home to hospital were described. Of the 3366 titles identified, 83 full text articles were screened, and 15 met the inclusion criteria. Two of the authors independently extracted the data. Because of the heterogeneity and lack of robustness across the studies, there were considerable risks for bias if performing meta-analyses. A descriptive presentation of the findings was chosen. Fifteen studies were eligible for inclusion, containing data from 215,257 women. The total proportion of transfer from home to hospital varied from 9.9% to 31.9% across the studies. The most common indication for transfer was labour dystocia, occurring in 5.1% to 9.8% of all women planning for home births. Transfer for indication for foetal distress varied from 1.0% to 3.6%, postpartum haemorrhage from 0% to 0.2% and respiratory problems in the infant from 0.3% to 1.4%. The proportion of emergency transfers varied from 0% to 5.4%. Future studies should report indications for transfer from home to hospital and provide clear definitions of emergency transfers.

  3. Super-paramagnetic core-shell material with tunable magnetic behavior by regulating electron transfer efficiency and structure stability of the shell

    Directory of Open Access Journals (Sweden)

    Wenyan Zhang

    Full Text Available In this work, a spherical nano core-shell material was constructed by encapsulating Fe3O4 microsphere into conductive polymer-metal composite shell. The Fe3O4 microspheres were fabricated by assembling large amounts of Fe3O4 nano-crystals, which endowed the microspheres with super-paramagnetic property and high saturation magnetization. The polymer-metal composite shell was constructed by inserting Pt nano-particles (NPs into the conductive polymer polypyrrole (PPy. As size and dispersion of the Pt NPs has an important influence on their surface area and surface energy, it was effective to enlarge the interface area between PPy and Pt NPs, enhance the electron transfer efficiency of PPy/Pt composite shell, and reinforced the shell’s structural stability just by tuning the size and dispersion of Pt NPs. Moreover, core-shell structure of the materials made it convenient to investigate the PPy/Pt shell’s shielding effect on the Fe3O4 core’s magnetic response to external magnetic fields. It was found that the saturation magnetization of Fe3O4/PPy/Pt core-shell material could be reduced by 20.5% by regulating the conductivity of the PPy/Pt shell. Keywords: Super-paramagnetic, Conductivity, Magnetic shielding, Structural stability

  4. Analysis of magnetic field measurement results for the AGS Booster magnets

    International Nuclear Information System (INIS)

    Bleser, E.; Thern, R.

    1991-01-01

    Magnetic field measurements have been made on nearly 200 conventional magnets that have been installed in the AGS Booster and its associated transfer lines. The measurements were intended to monitor the quality of the magnets being produced and to check the performance of each magnet before installation. The magnetic measurements effort led to certain improvements in the manufacturing process, which ten subsequently produced very good, very uniform magnets. The integrated dipole fields of the 36 booster dipoles are uniform to 1.5 parts in ten thousand. The magnetic measurements indicate that the quadrupoles were manufactured to an accuracy of 3 ten thousandths of an inch, which is better than we can physically measure. 3 refs., 2 figs., 4 tabs

  5. Magnetic field driven domain-wall propagation in magnetic nanowires

    International Nuclear Information System (INIS)

    Wang, X.R.; Yan, P.; Lu, J.; He, C.

    2009-01-01

    The mechanism of magnetic field induced magnetic domain-wall (DW) propagation in a nanowire is revealed: A static DW cannot exist in a homogeneous magnetic nanowire when an external magnetic field is applied. Thus, a DW must vary with time under a static magnetic field. A moving DW must dissipate energy due to the Gilbert damping. As a result, the wire has to release its Zeeman energy through the DW propagation along the field direction. The DW propagation speed is proportional to the energy dissipation rate that is determined by the DW structure. The negative differential mobility in the intermediate field is due to the transition from high energy dissipation at low field to low energy dissipation at high field. For the field larger than the so-called Walker breakdown field, DW plane precesses around the wire, leading to the propagation speed oscillation.

  6. Design of a variable-phase contactless energy transfer platform using air-cored planar inductor technology

    NARCIS (Netherlands)

    Sonntag, C.L.W.

    2010-01-01

    Contactless Energy Transfer (CET) describes the process in which electrical energy is transferred among two or more galvanically isolated electrical circuits or devices by means of magnetic induction (magnetic energy). The potential applications can range from the transfer of energy between low

  7. A magnetization transfer imaging study of bilateral optic radiation and visual cortex in patients with primary glaucoma

    International Nuclear Information System (INIS)

    Liang Wenwen; Zhang Xuelin; Jiang Xiaoyong; Xu Yongming; Yang Zhihui; Zhang Yan; Chang Renmin; Wang Jianping; Wu Guijun

    2012-01-01

    Objective: To analyse the changes in bilateral optic radiation and visual cortex in patients with primary glaucoma detected by magnetization transfer imaging (MTI), and try to explore the influence of the disease on posterior visual pathway. Methods: MTI was performed in 20 patients with primary glaucoma with normal signal on conventional magnetic resonance imaging (MRI). The same scanning was performed in 31 matched healthy controls. MTI was obtained using spoiled gradient recalled acquisition sequence (SPGR). Magnetization transfer ratio (MTR) of bilateral optic radiation and visual cortex was measured after post-processing. The MTR value differences of the same area between two groups were compared by independent-sample t test or Satterthwaite t test if variances were not equality. Result: The MTR value in the left and right optic radiation were (32.8 ± 2.2)% and (32.7 ± 2.0)% in the glaucoma group, (34.6 ± 1.4 )% and (34.8 ± 1.3)% in the control group. There was a statistically significant difference between the two groups (left t=3.284, right t=4.040; P<0.01). The MTR value of the left and right visual cortex were (30.1± 2.0)% and (30.8 ± 1.8)% in the glaucoma group, and (32.3 ± 1.2 )% and (32.4 ± 1.2)% in the control group. Statistically significant difference was found between the two groups (left t=4.319, right t=3.445; P<0.01). Conclusions: Potential neuropathology changes occurring in the posterior visual pathway of patients with glaucoma indicate that the whole visual pathway may be involved by glaucoma.The micro physiological changes can be detected by MTI which can not be found by conventional MRI. It is a useful method of studying trans-synaptic damage of visual pathway n vivo glaucoma which provides more information for guiding the clinic diagnosis, cure and prognosis of glaucoma. (authors)

  8. Nuclear magnetic resonance study of charge transfer complex formation between Silver Nitrate and Benzylcyanide in Solvent Ethylene Glycol

    International Nuclear Information System (INIS)

    Modarress, H.; Shekaari, H.

    2003-01-01

    The formation constant for charge transfer complexes between electron acceptor (AgNo 3 ) and electron donor benzylcyanide (C 6 H 5 -CH 2 -C≡N) in solvent ethyleneglycol [(CH 2 OH) 2 ] has been evaluated by using the nuclear magnetic resonance chemical shifts of aromatic group of benzylcyanide measured against external references, tetramethylsilane, hexamethyldisilane and cyclohexane at 20 d ig C . The external referencing procedure eliminated the interference of internal reference in the course of complexation. The necessary bulk magnetic susceptibility corrections on the measured chemical shifts have been made. The solution nationalised and their effects on the formation constant have been considered and a new equation has been suggested to obtain the main ionic activity coefficient of AgNO 3 from nuclear magnetic resonance results. The mean ionic activity coefficient has been taken into account in the formation constant calculations. The results indicated that the appropriate formation constant should be expressed in terms of activities. Also an equation have been derived to eliminate the undesirable effects on the nuclear magnetic resonance measured chemical shifts in calculating the constant. The selection of concentration domains and its effect on the calculated formation constant has been discussed and the new equation is modified to be independent of the concentration domains. In this equation the solution nationalised, by considering coefficients, have been taken in to account

  9. Magnetic induced heating of nanoparticle solutions

    Energy Technology Data Exchange (ETDEWEB)

    Murph, S. Hunyadi [Savannah River Site (SRS), Aiken, SC (United States); Univ. of Georgia, Athens, GA (United States); Brown, M. [Savannah River Site (SRS), Aiken, SC (United States); Coopersmith, K. [Savannah River Site (SRS), Aiken, SC (United States); Fulmer, S. [Savannah River Site (SRS), Aiken, SC (United States); Sessions, H. [Savannah River Site (SRS), Aiken, SC (United States); Ali, M. [Univ. of South Carolina, Columbia, SC (United States)

    2016-12-02

    Magnetic induced heating of nanoparticles (NP) provides a useful advantage for many energy transfer applications. This study aims to gain an understanding of the key parameters responsible for maximizing the energy transfer leading to nanoparticle heating through the use of simulations and experimental results. It was found that magnetic field strength, NP concentration, NP composition, and coil size can be controlled to generate accurate temperature profiles in NP aqueous solutions.

  10. The Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI

    Directory of Open Access Journals (Sweden)

    Masoomeh Fooladi

    2007-12-01

    Full Text Available Introduction: Multiple sclerosis (MS is a demyelinating disease of the central nervous system (CNS, affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathological heterogeneities that occur in MS lesions and brain tissue.Quantitative magnetization transfer imaging (qMTI is a relatively new MRI technique which can be used to examine the pathological processes of the brain parenchyma which occur in MS patients.This quantitative MRI technique can provide more complete information about the extent and nature of the brain tissue destruction in multiple sclerosis, which cannot be detected by conventional MRI. Material and Methods: In this study, twelve patients with relapsing-remitting MS and twelve healthy control subjects underwent conventional MR imaging including: T2-FSE, T1-SE and FLAIR sequences as well as quantitative magnetization transfer imaging. All the focal lesions were identified on T2-weighted images and were classified according to their signal hypointensity on T1-weighted scans. The white matter and MS lesions were segmented using a semi-automated system. MT ratio (MTR histogram analysis was performed for the brain white matter and the average MTR value was calculated for the classified MS lesions. Results: A significant reduction was found in MTR value of the normal appearing white matter (NAWM in patients with relapsing-remitting MS, suggesting that MS is a more diffuse disease, affecting the whole brain tissue. A wide range changes in MTR values can be observed in MS lesions. MTR reduction is correlated with the degree of lesion hypointensity on T1-weighted scans. The lower MTR values of lesions that appear progressively more hypointense on T1-weigted images reflect varying degrees of demyelination and

  11. Shot noise of spin current and spin transfer torque

    Science.gov (United States)

    Yu, Yunjin; Zhan, Hongxin; Wan, Langhui; Wang, Bin; Wei, Yadong; Sun, Qingfeng; Wang, Jian

    2013-04-01

    We report the theoretical investigation of the shot noise of the spin current (Sσ) and the spin transfer torque (Sτ) for non-collinear spin polarized transport in a spin-valve device which consists of a normal scattering region connected by two ferromagnetic electrodes (MNM system). Our theory was developed using the non-equilibrium Green’s function method, and general nonlinear Sσ - V and Sτ - V relations were derived as a function of the angle θ between the magnetizations of two leads. We have applied our theory to a quantum dot system with a resonant level coupled with two ferromagnetic electrodes. It was found that, for the MNM system, the auto-correlation of the spin current is enough to characterize the fluctuation of the spin current. For a system with three ferromagnetic layers, however, both auto-correlation and cross-correlation of the spin current are needed to characterize the noise of the spin current. For a quantum dot with a resonant level, the derivative of spin torque with respect to bias voltage is proportional to sinθ when the system is far away from resonance. When the system is near resonance, the spin transfer torque becomes a non-sinusoidal function of θ. The derivative of the noise of the spin transfer torque with respect to the bias voltage Nτ behaves differently when the system is near or far away from resonance. Specifically, the differential shot noise of the spin transfer torque Nτ is a concave function of θ near resonance while it becomes a convex function of θ far away from resonance. For certain bias voltages, the period Nτ(θ) becomes π instead of 2π. For small θ, it was found that the differential shot noise of the spin transfer torque is very sensitive to the bias voltage and the other system parameters.

  12. Transfer Efficiency Analysis of Wireless Power Transfer System under Frequency Drift

    DEFF Research Database (Denmark)

    Huang, Shoudao; Li, Zhongqi; Lu, Kaiyuan

    2015-01-01

    Magnetic resonant wireless power transfer (WPT) is an emerging technology that may create new applications for wireless power charging. However, low efficiency resulting from resonant frequency drift is a main obstructing factor for promoting this technology. In this paper, the system efficiency...

  13. Bond-order potential for magnetic body-centered-cubic iron and its transferability

    Science.gov (United States)

    Lin, Yi-Shen; Mrovec, M.; Vitek, V.

    2016-06-01

    We derived and thoroughly tested a bond-order potential (BOP) for body-centered-cubic (bcc) magnetic iron that can be employed in atomistic calculations of a broad variety of crystal defects that control structural, mechanical, and thermodynamic properties of this technologically important metal. The constructed BOP reflects correctly the mixed nearly free electron and covalent bonding arising from the partially filled d band as well as the ferromagnetism that is actually responsible for the stability of the bcc structure of iron at low temperatures. The covalent part of the cohesive energy is determined within the tight-binding bond model with the Green's function of the Schrödinger equation determined using the method of continued fractions terminated at a sufficient level of the moments of the density of states. This makes the BOP an O (N ) method usable for very large numbers of particles. Only d d bonds are included explicitly, but the effect of s electrons on the covalent energy is included via their screening of the corresponding d d bonds. The magnetic part of the cohesive energy is included using the Stoner model of itinerant magnetism. The repulsive part of the cohesive energy is represented, as in any tight-binding scheme, by an empirical formula. Its functional form is physically justified by studies of the repulsion in face-centered-cubic (fcc) solid argon under very high pressure where the repulsion originates from overlapping s and p closed-shell electrons just as it does from closed-shell s electrons in transition metals squeezed into the ion core under the influence of the large covalent d bonding. Testing of the transferability of the developed BOP to environments significantly different from those of the ideal bcc lattice was carried out by studying crystal structures and magnetic states alternative to the ferromagnetic bcc lattice, vacancies, divacancies, self-interstitial atoms (SIAs), paths continuously transforming the bcc structure to

  14. Energy transport in cooling device by magnetic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Hiroshi, E-mail: hyamaguc@mail.doshisha.ac.jp [Department of Mechanical Engineering, Doshisha University, Kyo-tanabe, Kyoto 610-0321 (Japan); Iwamoto, Yuhiro [Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya, Aichi 466-8555 (Japan)

    2017-06-01

    Temperature sensitive magnetic fluid has a great potential with high performance heat transport ability as well as long distance energy (heat) transporting. In the present study experimental set-up was newly designed and constructed in order to measure basic heat transport characteristics under various magnetic field conditions. Angular dependence for the device (heat transfer section) was also taken into consideration for a sake of practical applications. The energy transfer characteristic (heat transport capability) in the magnetically-driven heat transport (cooling) device using the binary TSMF was fully investigated with the set-up. The obtained results indicate that boiling of the organic mixture (before the magnetic fluid itself reaching boiling point) effectively enhances the heat transfer as well as boosting the flow to circulate in the closed loop by itself. A long-distance heat transport of 5 m is experimentally confirmed, transferring the thermal energy of 35.8 W, even when the device (circulation loop) is horizontally placed. The highlighted results reveal that the proposed cooling device is innovative in a sense of transporting substantial amount of thermal energy (heat) as well as a long distance heat transport. The development of the magnetically-driven heat transport device has a great potential to be replaced for the conventional heat pipe in application of thermal engineering. - Highlights: • Temperature-sensitive magnetic fluid (TSMF) has a great heat transport ability. • Magnetically-driven heat transport device using binary TSMF is proposed. • The basic heat transport characteristics are investigated. • Boiling of the organic mixture effectively enhances the heat transfer. • A long-distance heat transport of 5 m is experimentally confirmed.

  15. Energy transport in cooling device by magnetic fluid

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Iwamoto, Yuhiro

    2017-01-01

    Temperature sensitive magnetic fluid has a great potential with high performance heat transport ability as well as long distance energy (heat) transporting. In the present study experimental set-up was newly designed and constructed in order to measure basic heat transport characteristics under various magnetic field conditions. Angular dependence for the device (heat transfer section) was also taken into consideration for a sake of practical applications. The energy transfer characteristic (heat transport capability) in the magnetically-driven heat transport (cooling) device using the binary TSMF was fully investigated with the set-up. The obtained results indicate that boiling of the organic mixture (before the magnetic fluid itself reaching boiling point) effectively enhances the heat transfer as well as boosting the flow to circulate in the closed loop by itself. A long-distance heat transport of 5 m is experimentally confirmed, transferring the thermal energy of 35.8 W, even when the device (circulation loop) is horizontally placed. The highlighted results reveal that the proposed cooling device is innovative in a sense of transporting substantial amount of thermal energy (heat) as well as a long distance heat transport. The development of the magnetically-driven heat transport device has a great potential to be replaced for the conventional heat pipe in application of thermal engineering. - Highlights: • Temperature-sensitive magnetic fluid (TSMF) has a great heat transport ability. • Magnetically-driven heat transport device using binary TSMF is proposed. • The basic heat transport characteristics are investigated. • Boiling of the organic mixture effectively enhances the heat transfer. • A long-distance heat transport of 5 m is experimentally confirmed.

  16. Electromechanical capacitor for energy transfer

    International Nuclear Information System (INIS)

    Carroll, T.A.; Chowdhuri, P.; Marshall, J.

    1983-01-01

    Inductive energy transfer between two magnets can be achieved with almost 100% efficiency with a transfer capacitor. However, the bulk and cost will be high, and reliability low if conventional capacitors are used. A homopolar machine, used as a capacitor, will be compact and economical. A homopolar machine was designed with counter-rotating copper disks completely immersed in a liquid metal (NaK-78) to work as a pulse capacitor. Absence of solid-brush collectors minimized wear and frictional losses. Wetting of the copper disks throughout the periphery by the liquid metal minimized the resistive losses at the collector interface. A liquid-metal collector would, however, introduce hydrodynamic and magnetohydrodynamic losses. The selected liquid metal, e.g., NaK-78 will produce the lowest of such losses among the available liquid metals. An electromechanical capacitor of this design was tested at various dc magnetic fields. Its measured capacitance was about 100 farads at a dc magnetic field of 1.15 tesla

  17. Correction magnets for the Fermilab Recycler Ring

    International Nuclear Information System (INIS)

    James T Volk et al.

    2003-01-01

    In the commissioning of the Fermilab Recycler ring the need for higher order corrector magnets in the regions near beam transfers was discovered. Three types of permanent magnet skew quadrupoles, and two types of permanent magnet sextupoles were designed and built. This paper describes the need for these magnets, the design, assembly, and magnetic measurements

  18. Isotopic effect on the quantum tunneling of the magnetization of molecular nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Sessoli, Roberta E-mail: sessoli@chim1.unifi.it; Caneschi, Andrea; Gatteschi, Dante; Sorace, Lorenzo; Cornia, Andrea; Wernsdorfer, Wolfgang

    2001-05-01

    The molecular cluster [Fe{sub 8}(tacn){sub 6}O{sub 2}(OH){sub 12}]Br{sub 8}{center_dot}9H{sub 2}O, Fe{sub 8}, characterized by S=10, with biaxial magnetic anisotropy is an ideal system to investigate quantum effects in the dynamics of the magnetization. Resonant quantum tunneling gives rise to stepped hysteresis cycles and below 0.35 K pure quantum tunneling of the magnetization has been observed. The role of hyperfine fields in promoting the tunneling as a source of dynamic broadening of the states involved in the tunnel transition is investigated by preparing and characterizing two isotopically enriched samples using {sup 57}Fe and {sup 2}H. The relaxation rate in the tunneling regime is proportional to the hyperfine field generated by the nuclei. Also, the intrinsic linewidth of the tunneling resonance scales with the hyperfine field as confirmed by calculations of the super (or transfer) and direct hyperfine interactions. Preliminary results on a novel cluster of formula [Fe{sub 4}(OCH{sub 3}){sub 6}(dpm){sub 6}], Fe{sub 4}, suited for a more dramatic isotope effect on the tunneling rate are also reported.

  19. Static magnetic field reduced exogenous oligonucleotide uptake by spermatozoa using magnetic nanoparticle gene delivery system

    Science.gov (United States)

    Katebi, Samira; Esmaeili, Abolghasem; Ghaedi, Kamran

    2016-03-01

    Spermatozoa could introduce exogenous oligonucleotides of interest to the oocyte. The most important reason of low efficiency of sperm mediated gene transfer (SMGT) is low uptake of exogenous DNA by spermatozoa. The aim of this study was to evaluate the effects of static magnetic field on exogenous oligonucleotide uptake of spermatozoa using magnetofection method. Magnetic nanoparticles (MNPs) associated with the labeled oligonucleotides were used to increase the efficiency of exogenous oligonucleotide uptake by rooster spermatozoa. We used high-field/high-gradient magnet (NdFeB) to enhance and accelerate exogenous DNA sedimentation at the spermatozoa surface. Flow cytometry analysis was performed to measure viability and percentage of exogenous oligonucleotide uptake by sperm. Flow cytometry analysis showed a significant increase in exogenous oligonucleotide uptake by rooster spermatozoa (Prooster spermatozoa; however unlike others studies, static magnetic field, was not only ineffective to enhance exogenous oligonucleotide uptake by rooster spermatozoa but also led to reduction in efficiency of magnetic nanoparticles in gene transfer.

  20. Quantum tunneling of magnetization in single molecular magnets coupled to ferromagnetic reservoirs

    Science.gov (United States)

    Misiorny, M.; Barnas, J.

    2007-04-01

    The role of spin polarized reservoirs in quantum tunneling of magnetization and relaxation processes in a single molecular magnet (SMM) is investigated theoretically. The SMM is exchange-coupled to the reservoirs and also subjected to a magnetic field varying in time, which enables the quantum tunneling of magnetization. The spin relaxation times are calculated from the Fermi golden rule. The exchange interaction of SMM and electrons in the leads is shown to affect the spin reversal due to quantum tunneling of magnetization. It is shown that the switching is associated with transfer of a certain charge between the leads.

  1. EVOLUTION OF INTERMEDIATE-MASS X-RAY BINARIES DRIVEN BY THE MAGNETIC BRAKING OF AP/BP STARS. I. ULTRACOMPACT X-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Wen-Cong [School of Physics and Electrical Information, Shangqiu Normal University, Shangqiu 476000 (China); Podsiadlowski, Philipp, E-mail: chenwc@pku.edu.cn [Department of Physics, University of Oxford, Oxford OX1 3RH (United Kingdom)

    2016-10-20

    It is generally believed that ultracompact X-ray binaries (UCXBs) evolved from binaries consisting of a neutron star accreting from a low-mass white dwarf (WD) or helium star where mass transfer is driven by gravitational radiation. However, the standard WD evolutionary channel cannot produce the relatively long-period (40–60 minutes) UCXBs with a high time-averaged mass-transfer rate. In this work, we explore an alternative evolutionary route toward UCXBs, where the companions evolve from intermediate-mass Ap/Bp stars with an anomalously strong magnetic field (100–10,000 G). Including the magnetic braking caused by the coupling between the magnetic field and an irradiation-driven wind induced by the X-ray flux from the accreting component, we show that intermediate-mass X-ray binaries (IMXBs) can evolve into UCXBs. Using the MESA code, we have calculated evolutionary sequences for a large number of IMXBs. The simulated results indicate that, for a small wind-driving efficiency f = 10{sup −5}, the anomalous magnetic braking can drive IMXBs to an ultra-short period of 11 minutes. Comparing our simulated results with the observed parameters of 15 identified UCXBs, the anomalous magnetic braking evolutionary channel can account for the formation of seven and eight sources with f = 10{sup −3}, and 10{sup −5}, respectively. In particular, a relatively large value of f can fit three of the long-period, persistent sources with a high mass-transfer rate. Though the proportion of Ap/Bp stars in intermediate-mass stars is only 5%, the lifetime of the UCXB phase is ≳2 Gyr, producing a relatively high number of observable systems, making this an alternative evolutionary channel for the formation of UCXBs.

  2. Amperometric carbohydrate antigen 19-9 immunosensor based on three dimensional ordered macroporous magnetic Au film coupling direct electrochemistry of horseradish peroxidase

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qi [College of Sciences, Nanjing Tech University, Nanjing 211816 (China); Chen, Xiaojun, E-mail: chenxj_njut@126.com [College of Sciences, Nanjing Tech University, Nanjing 211816 (China); State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing 210009 (China); Tang, Yin [Zhangjiagang Hospital of Traditional Chinese Medicine, Zhangjiagang 215600 (China); Ge, Lingna; Guo, Buhua [College of Sciences, Nanjing Tech University, Nanjing 211816 (China); Yao, Cheng, E-mail: yaochengnjut@163.com [College of Sciences, Nanjing Tech University, Nanjing 211816 (China)

    2014-03-01

    Highlights: • Three dimensional ordered macroporous magnetic electrode was newly used in electrochemical immunosensor. • The large surface area of macroporous magnetic electrode could improve the immobilized amount of antibody. • Au nanoparticles functionalized SBA-15 was used to immobilize enzyme labeled Ab₂ and enzyme. • Macroporous magnetic electrode and Au nanoparticles composite facilitated the direct electron transfer of enzyme. • The immunoassay avoided adding electron transfer mediator, simplifying the procedure. Abstract: A sandwich-type electrochemical immunosensor for the detection of carbohydrate antigen 19-9 (CA 19-9) antigen based on the immobilization of primary antibody (Ab₁) on three dimensional ordered macroporous magnetic (3DOMM) electrode, and the direct electrochemistry of horseradish peroxidase (HRP) that was used as both the label of secondary antibody (Ab₂) and the blocking reagent. The 3DOMM electrode was fabricated by introducing core–shell Au–SiO₂@Fe₃O₄ nanospheres onto the surface of three dimensional ordered macroporous (3DOM) Au electrode via the application of an external magnet. Au nanoparticles functionalized SBA-15 (Au@SBA-15) was conjugated to the HRP labeled secondary antibody (HRP-Ab₂) through the Au–SH or Au–NH₃⁺ interaction, and HRP was also used as the block reagent. The formation of antigen–antibody complex made the combination of Au@SBA-15 and 3DOMM exhibit remarkable synergistic effects for accelerating direct electron transfer (DET) between HRP and the electrode. Under the optimal conditions, the DET current signal increased proportionally to CA 19-9 concentration in the range of 0.05 to 15.65 U mL⁻¹ with a detection limit of 0.01 U mL⁻¹. Moreover, the immunosensor showed high selectivity, good stability, satisfactory reproducibility and regeneration. Importantly, the developed method was used to assay clinical serum specimens, achieving a good relation with those obtained from

  3. Cost effective electronics for proportional and drift chambers of 'EPECUR' experiment

    International Nuclear Information System (INIS)

    Alekseev, I.G.; Andreev, V.A.; Budkovsky, P.E.; Filimonov, E.A.; Golubev, V.V.; Kanavets, V.P.; Kats, M.M.; Koroleva, L.I.; Kovalev, A.I.; Kozlenko, N.G.; Kozlov, V.S.; Krivshich, A.G.; Kulikov, V.V.; Morozov, B.V.; Nesterov, V.M.; Novinsky, D.V.; Ryltsov, V.V.; Sadler, M.E.; Sakharov, V.A.; Soboyede, D.; Sulimov, A.D.; Sumachev, V.V.; Svirida, D.N.; Trautman, V.Yu.; Walker, E.; Watson, S.

    2007-01-01

    The 'EPECUR' experimental setup is under construction at beam line 322 of the ITEP proton synchrotron. The experiment requires several large area drift chambers to provide reasonable acceptance and fine-pitch proportional chambers for beam particle tracking. The total number of electronic channels is about 7000. A new compact and cost effective readout system for these gaseous detectors was designed, prototyped and tested in the last two years. It is based on modern technologies in analog and digital electronics and data transfer protocols. This paper presents the functional description of the whole DAQ system, including test results as an illustration of its performance

  4. Failure Analysis in Magnetic Tunnel Junction Nanopillar with Interfacial Perpendicular Magnetic Anisotropy

    Directory of Open Access Journals (Sweden)

    Weisheng Zhao

    2016-01-01

    Full Text Available Magnetic tunnel junction nanopillar with interfacial perpendicular magnetic anisotropy (PMA-MTJ becomes a promising candidate to build up spin transfer torque magnetic random access memory (STT-MRAM for the next generation of non-volatile memory as it features low spin transfer switching current, fast speed, high scalability, and easy integration into conventional complementary metal oxide semiconductor (CMOS circuits. However, this device suffers from a number of failure issues, such as large process variation and tunneling barrier breakdown. The large process variation is an intrinsic issue for PMA-MTJ as it is based on the interfacial effects between ultra-thin films with few layers of atoms; the tunneling barrier breakdown is due to the requirement of an ultra-thin tunneling barrier (e.g., <1 nm to reduce the resistance area for the spin transfer torque switching in the nanopillar. These failure issues limit the research and development of STT-MRAM to widely achieve commercial products. In this paper, we give a full analysis of failure mechanisms for PMA-MTJ and present some eventual solutions from device fabrication to system level integration to optimize the failure issues.

  5. Analogical proportions: another logical view

    Science.gov (United States)

    Prade, Henri; Richard, Gilles

    This paper investigates the logical formalization of a restricted form of analogical reasoning based on analogical proportions, i.e. statements of the form a is to b as c is to d. Starting from a naive set theoretic interpretation, we highlight the existence of two noticeable companion proportions: one states that a is to b the converse of what c is to d (reverse analogy), while the other called paralogical proportion expresses that what a and b have in common, c and d have it also. We identify the characteristic postulates of the three types of proportions and examine their consequences from an abstract viewpoint. We further study the properties of the set theoretic interpretation and of the Boolean logic interpretation, and we provide another light on the understanding of the role of permutations in the modeling of the three types of proportions. Finally, we address the use of these proportions as a basis for inference in a propositional setting, and relate it to more general schemes of analogical reasoning. The differences between analogy, reverse-analogy, and paralogy is still emphasized in a three-valued setting, which is also briefly presented.

  6. Factors in the development of proportional reasoning strategies by concrete operational college students

    Science.gov (United States)

    Roth, Wolff-Michael; Milkent, Marlene M.

    This study was designed as a test for two neo-Piagetian theories. More specifically, this research examined the relationships between the development of proportional reasoning strategies and three cognitive variables from Pascual-Leone's and Case's neo-Piagetian theories. A priori hypotheses linked the number of problems students worked until they induced a proportional reasoning strategy to the variables of M-space, degree of field dependence, and short-term storage space. The subjects consisted of students enrolled in Physical Science I, a science course for nonscience majors at the University of Southern Mississippi. Of the 34 subjects in the study, 23 were classified as concrete operational on the basis of eight ratio tasks. Problems corresponding to five developmental levels of proportional reasoning (according to Piagetian and neo-Piagetian theory), were presented by a microcomputer to the 23 subjects who had been classified as concrete operational. After a maximum of 6 hours of treatment, 17 of the 23 subjects had induced ratio schemata at the upper formal level (IIIB), while the remaining subjects used lower formal level (IIIA) schemata. The data analyses showed that neither M-space and degree of field-dependence, either alone or in combination, nor short-term storage predicted the number of problems students need to do until they induce an appropriate problem-solving strategy. However, there were significant differences in the short-term storage space of those subjects who mastered ratio problems at the highest level and those who did not. Also, the subjects' degree of field-dependence was not a predictor of either the ability to transfer problem-solving strategies to a new setting or the reuse of inappropriate strategies. The results of this study also suggest that short-term storage space is a variable with high correlations to a number of aspects of learning such as transfer and choice of strategy after feedback.

  7. Theoretical analysis of magnetic sensor output voltage

    International Nuclear Information System (INIS)

    Liu Haishun; Dun Chaochao; Dou Linming; Yang Weiming

    2011-01-01

    The output voltage is an important parameter to determine the stress state in magnetic stress measurement, the relationship between the output voltage and the difference in the principal stresses was investigated by a comprehensive application of magnetic circuit theory, magnetization theory, stress analysis as well as the law of electromagnetic induction, and a corresponding quantitative equation was derived. It is drawn that the output voltage is proportional to the difference in the principal stresses, and related to the angle between the principal stress and the direction of the sensor. This investigation provides a theoretical basis for the principle stresses measurement by output voltage. - Research highlights: → A comprehensive investigation of magnetic stress signal. → Derived a quantitative equation about output voltage and the principal stresses. → The output voltage is proportional to the difference of the principal stresses. → Provide a theoretical basis for the principle stresses measurement.

  8. Energy transport in cooling device by magnetic fluid

    Science.gov (United States)

    Yamaguchi, Hiroshi; Iwamoto, Yuhiro

    2017-06-01

    Temperature sensitive magnetic fluid has a great potential with high performance heat transport ability as well as long distance energy (heat) transporting. In the present study experimental set-up was newly designed and constructed in order to measure basic heat transport characteristics under various magnetic field conditions. Angular dependence for the device (heat transfer section) was also taken into consideration for a sake of practical applications. The energy transfer characteristic (heat transport capability) in the magnetically-driven heat transport (cooling) device using the binary TSMF was fully investigated with the set-up. The obtained results indicate that boiling of the organic mixture (before the magnetic fluid itself reaching boiling point) effectively enhances the heat transfer as well as boosting the flow to circulate in the closed loop by itself. A long-distance heat transport of 5 m is experimentally confirmed, transferring the thermal energy of 35.8 W, even when the device (circulation loop) is horizontally placed. The highlighted results reveal that the proposed cooling device is innovative in a sense of transporting substantial amount of thermal energy (heat) as well as a long distance heat transport. The development of the magnetically-driven heat transport device has a great potential to be replaced for the conventional heat pipe in application of thermal engineering.

  9. Thin Co/Ni-based bottom pinned spin-transfer torque magnetic random access memory stacks with high annealing tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Tomczak, Y., E-mail: Yoann.Tomczak@imec.be [IMEC Kapeldreef 75, B-3001 Leuven (Belgium); Department of Chemistry, KU Leuven (University of Leuven), Celestijnenlaan 200F, B-3001 Leuven (Belgium); Swerts, J.; Mertens, S.; Lin, T.; Couet, S.; Sankaran, K.; Pourtois, G.; Kim, W.; Souriau, L.; Van Elshocht, S.; Kar, G.; Furnemont, A. [IMEC Kapeldreef 75, B-3001 Leuven (Belgium); Liu, E. [Department of Chemistry, KU Leuven (University of Leuven), Celestijnenlaan 200F, B-3001 Leuven (Belgium)

    2016-01-25

    Spin-transfer torque magnetic random access memory (STT-MRAM) is considered as a replacement for next generation embedded and stand-alone memory applications. One of the main challenges in the STT-MRAM stack development is the compatibility of the stack with CMOS process flows in which thermal budgets up to 400 °C are applied. In this letter, we report on a perpendicularly magnetized MgO-based tunnel junction (p-MTJ) on a thin Co/Ni perpendicular synthetic antiferromagnetic layer with high annealing tolerance. Tunnel magneto resistance (TMR) loss after annealing occurs when the reference layer loses its perpendicular magnetic anisotropy due to reduction of the CoFeB/MgO interfacial anisotropy. A stable Co/Ni based p-MTJ stack with TMR values of 130% at resistance-area products of 9 Ω μm{sup 2} after 400 °C anneal is achieved via moment control of the Co/Ta/CoFeB reference layer. Thinning of the CoFeB polarizing layer down to 0.8 nm is the key enabler to achieve 400 °C compatibility with limited TMR loss. Thinning the Co below 0.6 nm leads to a loss of the antiferromagnetic interlayer exchange coupling strength through Ru. Insight into the thickness and moment engineering of the reference layer is displayed to obtain the best magnetic properties and high thermal stability for thin Co/Ni SAF-based STT-MRAM stacks.

  10. A phenomenological SMA model for combined axial–torsional proportional/non-proportional loading conditions

    International Nuclear Information System (INIS)

    Bodaghi, M.; Damanpack, A.R.; Aghdam, M.M.; Shakeri, M.

    2013-01-01

    In this paper, a simple and robust phenomenological model for shape memory alloys (SMAs) is proposed to simulate main features of SMAs under uniaxial as well as biaxial combined axial–torsional proportional/non-proportional loadings. The constitutive model for polycrystalline SMAs is developed within the framework of continuum thermodynamics of irreversible processes. The model nominates the volume fractions of self-accommodated and oriented martensite as scalar internal variables and the preferred direction of oriented martensitic variants as directional internal variable. An algorithm is introduced to develop explicit relationships for the thermo-mechanical behavior of SMAs under uniaxial and biaxial combined axial–torsional proportional/non-proportional loading conditions and also thermal loading. It is shown that the model is able to simulate main aspects of SMAs including self-accommodation, martensitic transformation, orientation and reorientation of martensite, shape memory effect, ferro-elasticity and pseudo-elasticity. A description of the time-discrete counterpart of the proposed SMA model is presented. Experimental results of uniaxial tension and biaxial combined tension–torsion non-proportional tests are simulated and a good qualitative correlation between numerical and experimental responses is achieved. Due to simplicity and accuracy, the model is expected to be used in the future studies dealing with the analysis of SMA devices in which two stress components including one normal and one shear stress are dominant

  11. Performance evaluation of citric ion-stabilized magnetic fluid heat pipe

    Energy Technology Data Exchange (ETDEWEB)

    Jeyadevan, B. [Graduate School of Environmental Studies, Department of Geoscience and Technology, Tohoku University, Aramaki, Aoba 01, Aoba-ku, Sendai 980-7589 (Japan)]. E-mail: jeya@mail.kankyo.tohoku.ac.jp; Koganezawa, H. [Graduate School of Environmental Studies, Department of Geoscience and Technology, Tohoku University, Aramaki, Aoba 01, Aoba-ku, Sendai 980-7589 (Japan); Nakatsuka, K. [Graduate School of Environmental Studies, Department of Geoscience and Technology, Tohoku University, Aramaki, Aoba 01, Aoba-ku, Sendai 980-7589 (Japan)

    2005-03-15

    The performance of heat pipe (HP) using citric ion-stabilized magnetic fluid (CMF) as working fluid (WF) was evaluated. The heat transferred was influenced by the application of magnetic field and was enhanced by a maximum of 30% compared to the field-free case. Furthermore, under the optimum magnetic field configuration, the heat transferred by CMF HP was 10% higher than that with water as WF.

  12. Installation of the LHC transfer lines begins

    CERN Multimedia

    2003-01-01

    On 19 February, the very first magnet was installed in one of the two tunnels that will house the transfer lines leading to the LHC. This magnet, recycled from a previous facility, was transported and positioned using a novel system designed for conveying large objects through narrow tunnels.

  13. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  14. Composite magnetic particles

    International Nuclear Information System (INIS)

    Davies, G.E.; Janata, J.

    1981-01-01

    This patent claim on behalf of I.C.I. Ltd., relates to the preparation and use of composite magnetic particles, comprising a low density core, and having a magnetic coating over at least a proportion of the surface. The density of such particles can be chosen to suit a range of applications, e.g. in affinity chromatography, in radioimmunoassay, in the transport of the associated component, such as a drug or enzyme, to a specific site in a living organism. (U.K.)

  15. MESSENGER observations of magnetic reconnection in Mercury's magnetosphere.

    Science.gov (United States)

    Slavin, James A; Acuña, Mario H; Anderson, Brian J; Baker, Daniel N; Benna, Mehdi; Boardsen, Scott A; Gloeckler, George; Gold, Robert E; Ho, George C; Korth, Haje; Krimigis, Stamatios M; McNutt, Ralph L; Raines, Jim M; Sarantos, Menelaos; Schriver, David; Solomon, Sean C; Trávnícek, Pavel; Zurbuchen, Thomas H

    2009-05-01

    Solar wind energy transfer to planetary magnetospheres and ionospheres is controlled by magnetic reconnection, a process that determines the degree of connectivity between the interplanetary magnetic field (IMF) and a planet's magnetic field. During MESSENGER's second flyby of Mercury, a steady southward IMF was observed and the magnetopause was threaded by a strong magnetic field, indicating a reconnection rate ~10 times that typical at Earth. Moreover, a large flux transfer event was observed in the magnetosheath, and a plasmoid and multiple traveling compression regions were observed in Mercury's magnetotail, all products of reconnection. These observations indicate that Mercury's magnetosphere is much more responsive to IMF direction and dominated by the effects of reconnection than that of Earth or the other magnetized planets.

  16. Effect of liquid inertia on bubble growth in the presence of a magnetic field

    International Nuclear Information System (INIS)

    Wagner, L.Y.; Lykoudis, P.S.

    1977-01-01

    Liquid metal bubble growth in the presence of a magnetic field has previously been examined by Lykoudis under the assumption that the process is heat transfer controlled. In the present work, the growth of a bubble under the influence of a magnetic field is considered when the effect of the liquid inertia is included. This yields a better description of the phenomena for liquid metals, due to the greater portion of the growth cycle that is dominated by the liquid inertia forces. The results indicate that liquid inertia can significantly affect the growth of a liquid metal bubble when compared with the heat transfer-controlled case. The overall effect of the magnetic field forces the heat transfer-controlled growth to occur earlier in the life of the bubble. Hence, heat transfer effects dominate the growth stage more as the magnetic field is increased. The inertia effects are damped and, in the limit of high magnetic fields, growth is only heat transfer controlled. The heat transfer estimates made in the fashion of Forster and Zuber indicate that the magnetic field reduces the energy transport in nucleate boiling. 5 figures

  17. Imaging in Vivo Extracellular pH with a Single Paramagnetic Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agent

    Directory of Open Access Journals (Sweden)

    Guanshu Liu

    2012-01-01

    Full Text Available The measurement of extracellular pH (pHe has potential utility for cancer diagnoses and for assessing the therapeutic effects of pH-dependent therapies. A single magnetic resonance imaging (MRI contrast agent that is detected through paramagnetic chemical exchange saturation transfer (PARACEST was designed to measure tumor pHe throughout the range of physiologic pH and with magnetic resonance saturation powers that are not harmful to a mouse model of cancer. The chemical characterization and modeling of the contrast agent Yb3+-1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid, 10-o-aminoanilide (Yb-DO3A-oAA suggested that the aryl amine of the agent forms an intramolecular hydrogen bond with a proximal carboxylate ligand, which was essential for generating a practical chemical exchange saturation transfer (CEST effect from an amine. A ratio of CEST effects from the aryl amine and amide was linearly correlated with pH throughout the physiologic pH range. The pH calibration was used to produce a parametric pH map of a subcutaneous flank tumor on a mouse model of MCF-7 mammary carcinoma. Although refinements in the in vivo CEST MRI methodology may improve the accuracy of pHe measurements, this study demonstrated that the PARACEST contrast agent can be used to generate parametric pH maps of in vivo tumors with saturation power levels that are not harmful to a mouse model of cancer.

  18. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  19. MFTF magnet cryostability

    International Nuclear Information System (INIS)

    VanSant, J.H.

    1979-01-01

    A pair of large superconducting magnets will be installed in the Mirror Fusion Test Facility (MFTF), which is to begin operation in 1981. To ensure a stable superconducting state for the niobium-titanium (Nb-Ti) conductor, special consideration has been given to certain aspects of the magnet system design. These include the conductor, joints, coil assembly, vapor plenums, liquid-helium (LHe) supply system, and current leads. Heat transfer is the main consideration; i.e., the helium quality and temperature are limited so that the superconductor will perform satisfactorily in the magnet environment

  20. Research on Wireless Power Transfer System via Magnetically Coupled Resonance

    Directory of Open Access Journals (Sweden)

    ZHU Meng

    2017-04-01

    Full Text Available In order to extend the transmission distance and improve the transmission efficiency of the traditional wireless power transmission(WPTsystem composed with the transmitting and receiving coil resonators based on magnetic resonance coupling,we proposed an effective method to add a magnetic core between repeating coil and receiving coil based on the single repeating three coils mode. This paper deduced a mathematical expression of the transmission efficiency,and built a model by the circuit theory,and also simulated the transmission system added with the magnetic core between repeating and receiving coil. Then we selected the flat magnetic core for test. At last,we verified the feasibility of the proposal by actual experiment.

  1. Magnetic Field Emission Comparison for Series-Parallel and Series-Series Wireless Power Transfer to Vehicles – PART 2/2

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Series-series and series-parallel topologies are the most favored topologies for design of wireless power transfer system for vehicle applications. The series-series topology has the advantage of reflecting only the resistive part on the primary side. On the other hand, the current source output...... characteristics of the series-parallel topology are more suited for the battery of the vehicle. This paper compares the two topologies in terms of magnetic emissions to the surroundings for the same input power, primary current, quality factor and inductors. Theoretical and simulation results show that the series...

  2. Magnetic Field Emission Comparison for Series-Parallel and Series-Series Wireless Power Transfer to Vehicles – PART 1/2

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Resonant circuits of wireless power transfer system can be designed in four possible ways by placing the primary and secondary capacitor in a series or parallel order with respect to the corresponding inductor. The two topologies series-parallel and series-series under investigation have been...... already compared in terms of their output behavior (current or voltage source) and reflection of the secondary impedance on the primary side. In this paper it is shown that for the same power rating series-parallel topology emits lesser magnetic fields to the surroundings than its series...

  3. Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

    Science.gov (United States)

    Chou, I-Jun; Lim, Su-Yin; Tanasescu, Radu; Al-Radaideh, Ali; Mougin, Olivier E; Tench, Christopher R; Whitehouse, William P; Gowland, Penny A; Constantinescu, Cris S

    2018-03-01

    Fluid-attenuated inversion recovery (FLAIR) imaging at 3 Tesla (T) field strength is the most sensitive modality for detecting white matter lesions in multiple sclerosis. While 7T FLAIR is effective in detecting cortical lesions, it has not been fully optimized for visualization of white matter lesions and thus has not been used for delineating lesions in quantitative magnetic resonance imaging (MRI) studies of the normal appearing white matter in multiple sclerosis. Therefore, we aimed to evaluate the sensitivity of 7T magnetization-transfer-weighted (MT w ) images in the detection of white matter lesions compared with 3T-FLAIR. Fifteen patients with clinically isolated syndrome, 6 with multiple sclerosis, and 10 healthy participants were scanned with 7T 3-dimensional (D) MT w and 3T-2D-FLAIR sequences on the same day. White matter lesions visible on either sequence were delineated. Of 662 lesions identified on 3T-2D-FLAIR images, 652 were detected on 7T-3D-MT w images (sensitivity, 98%; 95% confidence interval, 97% to 99%). The Spearman correlation coefficient between lesion loads estimated by the two sequences was .910. The intrarater and interrater reliability for 7T-3D-MT w images was good with an intraclass correlation coefficient (ICC) of 98.4% and 81.8%, which is similar to that for 3T-2D-FLAIR images (ICC 96.1% and 96.7%). Seven-Tesla MT w sequences detected most of the white matter lesions identified by FLAIR at 3T. This suggests that 7T-MT w imaging is a robust alternative for detecting demyelinating lesions in addition to 3T-FLAIR. Future studies need to compare the roles of optimized 7T-FLAIR and of 7T-MT w imaging. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  4. Delayed demagnetization jumps in (NdDy)(FeCo)B magnets in a steady-state magnetic field

    Science.gov (United States)

    L'vova, G. L.; Kirman, M. V.; Koplak, O. V.; Kucheryaev, V. V.; Valeev, R. A.; Piskorskii, V. P.; Morgunov, R. B.

    2017-11-01

    Spontaneous demagnetization jumps are observed in sintered magnets (Nd0.6Dy0.4)16(Fe0.77Co0.23)78B6 in a constant magnetic field after a sharp decrease in an external magnetic field from the value corresponding to the saturation to a value close to the coercive force. It is shown that the number of the magnetization jumps is proportional to their amplitudes. A low value of the autocorrelation coefficient between the jump amplitude and the time of its appearance ( R white magnetic noise is observed. The distribution of the magnetic field gradient has been obtained near the sample surface that makes it possible to distinguish domains and the grain magnetization in the dependence on the direction of the texturing of the sintered magnet.

  5. The Principle of Proportionality

    DEFF Research Database (Denmark)

    Bennedsen, Morten; Meisner Nielsen, Kasper

    2005-01-01

    Recent policy initiatives within the harmonization of European company laws have promoted a so-called "principle of proportionality" through proposals that regulate mechanisms opposing a proportional distribution of ownership and control. We scrutinize the foundation for these initiatives...... in relationship to the process of harmonization of the European capital markets.JEL classifications: G30, G32, G34 and G38Keywords: Ownership Structure, Dual Class Shares, Pyramids, EU companylaws....

  6. Wireless digital information transfer : Modelling, prediction and assessment

    NARCIS (Netherlands)

    Lager, I.E.; De Hoop, A.T.; Kikkawa, T.

    2013-01-01

    The loop-to-loop pulsed electromagnetic field wireless signal transfer is investigated with a view on its application in wireless digital information transfer. Closed-form expressions are derived for the emitted magnetic field and for the open-circuit voltage of the receiving loop in dependence on

  7. Magnetization transfer imaging of normal and abnormal testis: preliminary results

    International Nuclear Information System (INIS)

    Tsili, Athina C.; Ntorkou, Alexandra; Maliakas, Vasilios; Argyropoulou, Maria I.; Baltogiannis, Dimitrios; Sylakos, Anastasios; Sofikitis, Nikolaos; Stavrou, Sotirios; Astrakas, Loukas G.

    2016-01-01

    The aim was to determine the magnetization transfer ratio (MTR) of normal testes, possible variations with age and to assess the feasibility of MTR in characterizing various testicular lesions. Eighty-six men were included. A three-dimensional gradient-echo MT sequence was performed, with/without an on-resonance binomial prepulse. MTR was calculated as: (SIo-SIm)/(SIo) x 100 %, where SIm and SIo refers to signal intensities with and without the saturation pulse, respectively. Subjects were classified as: group 1, 20-39 years; group 2, 40-65 years; and group 3, older than 65 years of age. Analysis of variance (ANOVA) followed by the least significant difference test was used to assess variations of MTR with age. Comparison between the MTR of normal testis, malignant and benign testicular lesions was performed using independent-samples t testing. ANOVA revealed differences of MTR between age groups (F = 7.51, P = 0.001). Significant differences between groups 1, 2 (P = 0.011) and 1, 3 (P < 0.001) were found, but not between 2, 3 (P = 0.082). The MTR (in percent) of testicular carcinomas was 55.0 ± 3.2, significantly higher than that of benign lesions (50.3 ± 4.0, P = 0.02) and of normal testes (47.4 ± 2.2, P < 0.001). MTR of normal testes decreases with age. MTR might be helpful in the diagnostic work-up of testicular lesions. (orig.)

  8. Giant Spin Hall Effect and Switching Induced by Spin-Transfer Torque in a W /Co40Fe40B20/MgO Structure with Perpendicular Magnetic Anisotropy

    Science.gov (United States)

    Hao, Qiang; Xiao, Gang

    2015-03-01

    We obtain robust perpendicular magnetic anisotropy in a β -W /Co40Fe40B20/MgO structure without the need of any insertion layer between W and Co40Fe40B20 . This is achieved within a broad range of W thicknesses (3.0-9.0 nm), using a simple fabrication technique. We determine the spin Hall angle (0.40) and spin-diffusion length for the bulk β form of tungsten with a large spin-orbit coupling. As a result of the giant spin Hall effect in β -W and careful magnetic annealing, we significantly reduce the critical current density for the spin-transfer-torque-induced magnetic switching in Co40Fe40B20 . The elemental β -W is a superior candidate for magnetic memory and spin-logic applications.

  9. Pulsed magnetization transfer contrast MRI by a sequence with water selective excitation

    Energy Technology Data Exchange (ETDEWEB)

    Schick, F. [Univ. of Tuebingen (Germany)

    1996-01-01

    A water selective SE imaging sequence was developed providing suitable properties for the assessment of magnetization transfer (MT) effects in tissues with considerable amounts of fat. The sequence with water selective excitation and slice selective refocusing combines the following features: The RIF exposure on the macromolecular protons is relatively low for single slice imaging without MT prepulses, since no additional pulses for fat saturation are necessary. Water selection by frequency selective excitation diminishes faults in the subtraction of images recorded with and without MT prepulses (which might arise from movements). High differences in the signal amplitudes from hyaline cartilage and muscle tissue were obtained comparing images recorded with irradiation of the series of prepulses for MT and those lacking MT prepulses. Utilizations of the described water selective approach for the assessment of MT effects in lesions of cartilage and bone are demonstrated. MT saturation was also examined in muscles with fatty degeneration of patients suffering from progressive muscular dystrophy. The described technique allows determination of MT effects with good precision in a single slice, especially in regions with dominating fat signals. 22 refs., 5 figs.

  10. On the topology of flux transfer events

    Science.gov (United States)

    Hesse, Michael; Birn, Joachim; Schindler, Karl

    1990-01-01

    A topological analysis is made of a simple model magnetic field of a perturbation at the magnetopause that shares magnetic properties with flux transfer events. The aim is to clarify a number of topological aspects that arise in the case of fully three-dimensional magnetic fields. It is shown that a localized perturbation at the magnetopause can in principle open a closed magnetosphere by establishing magnetic connections across the magnetopause by the formation of a ropelike magnetic field structure. For this purpose a global topological model of a closed magnetosphere is considered as the unperturbed state. The topological substructure of the model flux rope is discussed in detail.

  11. Amplification of large-scale magnetic field in nonhelical magnetohydrodynamics

    KAUST Repository

    Kumar, Rohit

    2017-08-11

    It is typically assumed that the kinetic and magnetic helicities play a crucial role in the growth of large-scale dynamo. In this paper, we demonstrate that helicity is not essential for the amplification of large-scale magnetic field. For this purpose, we perform nonhelical magnetohydrodynamic (MHD) simulation, and show that the large-scale magnetic field can grow in nonhelical MHD when random external forcing is employed at scale 1/10 the box size. The energy fluxes and shell-to-shell transfer rates computed using the numerical data show that the large-scale magnetic energy grows due to the energy transfers from the velocity field at the forcing scales.

  12. Magnetization Transfer Magnetic Resonance Imaging Noninvasively Detects Renal Fibrosis in Swine Atherosclerotic Renal Artery Stenosis at 3.0 T.

    Science.gov (United States)

    Jiang, Kai; Ferguson, Christopher M; Woollard, John R; Zhu, Xiangyang; Lerman, Lilach O

    2017-11-01

    Renal fibrosis is a useful biomarker for diagnosis and evaluation of therapeutic interventions of renal diseases but often requires invasive testing. Magnetization transfer magnetic resonance imaging (MT-MRI), which evaluates the presence of macromolecules, offers a noninvasive tool to probe renal fibrosis in murine renal artery stenosis (RAS) at 16.4 T. In this study, we aimed to identify appropriate imaging parameters for collagen detection at 3.0 T MRI and to test the utility of MT-MRI in measuring renal fibrosis in a swine model of atherosclerotic RAS (ARAS). To select the appropriate offset frequency, an MT-MRI study was performed on a phantom containing 0% to 40% collagen I and III with offset frequencies from -1600 to +1600 Hz and other MT parameters empirically set as pulse width at 16 milliseconds and flip angle at 800 degrees. Then selected MT parameters were used in vivo on pigs 12 weeks after sham (n = 8) or RAS (n = 10) surgeries. The ARAS pigs were fed with high-cholesterol diet to induce atherosclerosis. The MT ratio (MTR) was compared with ex vivo renal fibrosis measured using Sirius-red staining. Offset frequencies at 600 and 1000 Hz were selected for collagen detection without direct saturation of free water signal, and subsequently applied in vivo. The ARAS kidneys showed mild cortical and medullary fibrosis by Sirius-red staining. The cortical and medullary MTRs at 600 and 1000 Hz were both increased. Renal fibrosis measured ex vivo showed good linear correlations with MTR at 600 (cortex: Pearson correlation coefficient r = 0.87, P 3.0 T. Therefore, MT-MRI may potentially be clinically applicable and useful for detection and monitoring of renal pathology in subjects with RAS.

  13. On Thermodynamic Interpretation of Transfer Entropy

    Directory of Open Access Journals (Sweden)

    Don C. Price

    2013-02-01

    Full Text Available We propose a thermodynamic interpretation of transfer entropy near equilibrium, using a specialised Boltzmann’s principle. The approach relates conditional probabilities to the probabilities of the corresponding state transitions. This in turn characterises transfer entropy as a difference of two entropy rates: the rate for a resultant transition and another rate for a possibly irreversible transition within the system affected by an additional source. We then show that this difference, the local transfer entropy, is proportional to the external entropy production, possibly due to irreversibility. Near equilibrium, transfer entropy is also interpreted as the difference in equilibrium stabilities with respect to two scenarios: a default case and the case with an additional source. Finally, we demonstrated that such a thermodynamic treatment is not applicable to information flow, a measure of causal effect.

  14. Evaluating Middle Years Students' Proportional Reasoning

    Science.gov (United States)

    Hilton, Annette; Dole, Shelley; Hilton, Geoff; Goos, Merrilyn; O'Brien, Mia

    2012-01-01

    Proportional reasoning is a key aspect of numeracy that is not always developed naturally by students. Understanding the types of proportional reasoning that students apply to different problem types is a useful first step to identifying ways to support teachers and students to develop proportional reasoning in the classroom. This paper describes…

  15. Magnetic electron scattering

    International Nuclear Information System (INIS)

    Peterson, G.A.

    1989-01-01

    We briefly review some of the motivations, early results, and techniques of magnetic elastic and inelastic electron-nucleus scattering. We then discuss recent results, especially those acquired at high momentum transfers. 50 refs., 19 figs

  16. Magnetization switching driven by spin-transfer-torque in high-TMR magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Aurelio, D.; Torres, L.; Finocchio, G.

    2009-01-01

    This paper presents a numerical study of magnetization switching driven by spin-polarized current in high-TMR magnetic tunnel junctions (TMR>100%). The current density distribution throughout the free-layer is computed dynamically, by modeling the ferromagnet/insulator/ferromagnet trilayer as a series of parallel resistances. The validity of the main hypothesis, which states that the current flows perpendicular to the sample plane, has been verified by numerically solving the Poisson equation. Our results show that the nonuniform current density distribution is a source of asymmetry to the switching process. Furthermore, we observe that the reversal mechanisms are characterized by well-defined localized pre-switching oscillation modes.

  17. New ALPHA-2 magnet

    CERN Multimedia

    Anaïs Schaeffer

    2012-01-01

    On 21 June, members of the ALPHA collaboration celebrated the handover of the first solenoid designed for the ALPHA-2 experiment. The magnet has since been successfully installed and is working well.   Khalid Mansoor, Sumera Yamin and Jeffrey Hangst in front of the new ALPHA-2 solenoid. “This was the first of three identical solenoids that will be installed between now and September, as the rest of the ALPHA-2 device is installed and commissioned,” explains ALPHA spokesperson Jeffrey Hangst. “These magnets are designed to allow us to transfer particles - antiprotons, electrons and positrons - between various parts of the new ALPHA-2 device by controlling the transverse size of the particle bunch that is being transferred.” Sumera Yamin and Khalid Mansoor, two Pakistani scientists from the National Centre for Physics in Islamabad, came to CERN in February specifically to design and manufacture these magnets. “We had the chance to work on act...

  18. 31P magnetization transfer measurements of Pi→ATP flux in exercising human muscle.

    Science.gov (United States)

    Sleigh, Alison; Savage, David B; Williams, Guy B; Porter, David; Carpenter, T Adrian; Brindle, Kevin M; Kemp, Graham J

    2016-03-15

    Fundamental criticisms have been made over the use of (31)P magnetic resonance spectroscopy (MRS) magnetization transfer estimates of inorganic phosphate (Pi)→ATP flux (VPi-ATP) in human resting skeletal muscle for assessing mitochondrial function. Although the discrepancy in the magnitude of VPi-ATP is now acknowledged, little is known about its metabolic determinants. Here we use a novel protocol to measure VPi-ATP in human exercising muscle for the first time. Steady-state VPi-ATP was measured at rest and over a range of exercise intensities and compared with suprabasal oxidative ATP synthesis rates estimated from the initial rates of postexercise phosphocreatine resynthesis (VATP). We define a surplus Pi→ATP flux as the difference between VPi-ATP and VATP. The coupled reactions catalyzed by the glycolytic enzymes GAPDH and phosphoglycerate kinase (PGK) have been shown to catalyze measurable exchange between ATP and Pi in some systems and have been suggested to be responsible for this surplus flux. Surplus VPi-ATP did not change between rest and exercise, even though the concentrations of Pi and ADP, which are substrates for GAPDH and PGK, respectively, increased as expected. However, involvement of these enzymes is suggested by correlations between absolute and surplus Pi→ATP flux, both at rest and during exercise, and the intensity of the phosphomonoester peak in the (31)P NMR spectrum. This peak includes contributions from sugar phosphates in the glycolytic pathway, and changes in its intensity may indicate changes in downstream glycolytic intermediates, including 3-phosphoglycerate, which has been shown to influence the exchange between ATP and Pi catalyzed by GAPDH and PGK. Copyright © 2016 the American Physiological Society.

  19. Influence of cooling rate in planar thermally assisted magnetic random access memory: Improved writeability due to spin-transfer-torque influence

    International Nuclear Information System (INIS)

    Chavent, A.; Ducruet, C.; Portemont, C.; Creuzet, C.; Alvarez-Hérault, J.; Vila, L.; Sousa, R. C.; Prejbeanu, I. L.; Dieny, B.

    2015-01-01

    This paper investigates the effect of a controlled cooling rate on magnetic field reversal assisted by spin transfer torque (STT) in thermally assisted magnetic random access memory. By using a gradual linear decrease of the voltage at the end of the write pulse, the STT decays more slowly or at least at the same rate as the temperature. This condition is necessary to make sure that the storage layer magnetization remains in the desired written direction during cooling of the cell. The influence of the write current pulse decay rate was investigated on two exchange biased synthetic ferrimagnet (SyF) electrodes. For a NiFe based electrode, a significant improvement in writing reproducibility was observed using a gradual linear voltage transition. The write error rate decreases by a factor of 10 when increasing the write pulse fall-time from ∼3 ns to 70 ns. For comparison, a second CoFe/NiFe based electrode was also reversed by magnetic field assisted by STT. In this case, no difference between sharp and linear write pulse fall shape was observed. We attribute this observation to the higher thermal stability of the CoFe/NiFe electrode during cooling. In real-time measurements of the magnetization reversal, it was found that Ruderman-Kittel-Kasuya-Yosida (RKKY) coupling in the SyF electrode vanishes for the highest pulse voltages that were used due to the high temperature reached during write. As a result, during the cooling phase, the final state is reached through a spin-flop transition of the SyF storage layer

  20. Optical fusions and proportional syntheses

    Science.gov (United States)

    Albert-Vanel, Michel

    2002-06-01

    A tragic error is being made in the literature concerning matters of color when dealing with optical fusions. They are still considered to be of additive nature, whereas experience shows us somewhat different results. The goal of this presentation is to show that fusions are, in fact, of 'proportional' nature, tending to be additive or subtractive, depending on each individual case. Using the pointillist paintings done in the manner of Seurat, or the spinning discs experiment could highlight this intermediate sector of the proportional. So, let us try to examine more closely what occurs in fact, by reviewing additive, subtractive and proportional syntheses.

  1. Shot noise of spin current and spin transfer torque

    International Nuclear Information System (INIS)

    Yu Yunjin; Zhan Hongxin; Wan Langhui; Wang Bin; Wei Yadong; Sun Qingfeng; Wang Jian

    2013-01-01

    We report the theoretical investigation of the shot noise of the spin current (S σ ) and the spin transfer torque (S τ ) for non-collinear spin polarized transport in a spin-valve device which consists of a normal scattering region connected by two ferromagnetic electrodes (MNM system). Our theory was developed using the non-equilibrium Green’s function method, and general nonlinear S σ − V and S τ − V relations were derived as a function of the angle θ between the magnetizations of two leads. We have applied our theory to a quantum dot system with a resonant level coupled with two ferromagnetic electrodes. It was found that, for the MNM system, the auto-correlation of the spin current is enough to characterize the fluctuation of the spin current. For a system with three ferromagnetic layers, however, both auto-correlation and cross-correlation of the spin current are needed to characterize the noise of the spin current. For a quantum dot with a resonant level, the derivative of spin torque with respect to bias voltage is proportional to sinθ when the system is far away from resonance. When the system is near resonance, the spin transfer torque becomes a non-sinusoidal function of θ. The derivative of the noise of the spin transfer torque with respect to the bias voltage N τ behaves differently when the system is near or far away from resonance. Specifically, the differential shot noise of the spin transfer torque N τ is a concave function of θ near resonance while it becomes a convex function of θ far away from resonance. For certain bias voltages, the period N τ (θ) becomes π instead of 2π. For small θ, it was found that the differential shot noise of the spin transfer torque is very sensitive to the bias voltage and the other system parameters. (paper)

  2. Weak nonlinear analysis of magneto–convection under magnetic field modulation

    International Nuclear Information System (INIS)

    Bhadauria, B S; Kiran, Palle

    2014-01-01

    An analytic study of heat transport in an electrically conducting fluid layer is performed under a non-uniform time-dependent magnetic field. The applied vertical magnetic field consists of two parts: a constant part and a time-dependent periodic part, which varies sinusoidally with time. A weakly nonlinear theory has been considered to investigate heat transfer in the fluid layer. The heat transfer coefficient is obtained by deriving the non-autonomous Ginzburg–Landau equation for an amplitude of convection. This amplitude of convection is derived by using NDSolve Mathematica 8, and the results are verified using Runge–Kutta–Fehlberg method. The Nusselt number is obtained in terms of various system parameters and the effect of each parameter on heat transport is reported in detail. The effect of magnetic Prandtl number Pm, amplitude of modulation δ is to enhance the heat transfer. The Chandrasekhar number Q, modulation frequency ω is to stabilize the system. Further, it is found that magnetic modulation can be used effectively in either enhancing the heat transfer or diminishing it. (paper)

  3. Magnetization transfer ratio in the brain of preterm subjects: age-related changes during the first 2 years of life

    Energy Technology Data Exchange (ETDEWEB)

    Xydis, Vassilios; Astrakas, Loukas; Zikou, Anastasia; Argyropoulou, Maria I. [University of Ioannina, Department of Radiology, Medical School, Ioannina (Greece); Pantou, Kostandina; Andronikou, Styliani [Medical School University of Ioannina, Neonatology Clinic, Child Health Department, Ioannina (Greece)

    2006-01-01

    To study the progress of myelination in preterm-born subjects by measuring the MT ratio (MTR) from birth, up to 24 months of corrected age.One hundred twenty-five preterm subjects (64 males and 61 females of gestational age 33{+-}2.4 weeks with chronologic and corrected age of 9.3{+-}5.1 and 7.7{+-}5.1 months, respectively) with normal brain MR using classic sequences were further evaluated for MTR by using a three-dimensional gradient-echo sequence (TR=32/TE=8/flip angle=6 4 mm/2 mm overlapping sections) with and without magnetization transfer prepulse. The magnetization transfer ratio was calculated as: MTR=(SIo-SIm)/SIo x 100%, where SIm refers to signal intensity from an image acquired with a MT prepulse and SIo the signal intensity from the image acquired without a MT prepulse. MTR increased asymptotically in the genu (R{sup 2}=0.85) and splenium (R{sup 2}=0.85) of the corpus callosum, the white matter of the frontal lobe (R{sup 2}=0.91) and occipital lobe (R{sup 2}=0.82), thalamus (R{sup 2}=0.86), caudate nucleus (R{sup 2}=0.67) and putamen (R{sup 2}=0.71), reaching the 95% of the final value at the corrected age 18.7, 17.7, 15.6, 12.9, 10.4, 9.2 and 6.4 months, respectively. This study shows age-related changes of the brain MTR and provides data that may be useful to assess disturbances in the progress of myelination. (orig.)

  4. Zero sound and quasiwave: separation in the magnetic field

    International Nuclear Information System (INIS)

    Bezuglyj, E.V.; Bojchuk, A.V.; Burma, N.G.; Fil', V.D.

    1995-01-01

    Theoretical and experimental results on the behavior of the longitudinal and transverse electron sound in a weak magnetic field are presented. It is shown theoretically that the effects of the magnetic field on zero sound velocity and ballistic transfer are opposite in sign and have sufficiently different dependences on the sample width, excitation frequency and relaxation time. This permits us to separate experimentally the Fermi-liquid and ballistic contributions in the electron sound signals. For the first time the ballistic transfer of the acoustic excitation by the quasiwave has been observed in zero magnetic field

  5. Quantum state transfer via a two-qubit Heisenberg XXZ spin model

    Energy Technology Data Exchange (ETDEWEB)

    Liu Jia; Zhang Guofeng [Department of Physics, Beijing University of Aeronautics and Astronautics, Beijing 100083 (China); Chen Ziyu [Department of Physics, Beijing University of Aeronautics and Astronautics, Beijing 100083 (China)], E-mail: chenzy@buaa.edu.cn

    2008-04-14

    Transfer of quantum states through a two-qubit Heisenberg XXZ spin model with a nonuniform magnetic field b is investigated by means of quantum theory. The influences of b, the spin exchange coupling J and the effective transfer time T=Jt on the fidelity have been studied for some different initial states. Results show that fidelity of the transferred state is determined not only by J, T and b but also by the initial state of this quantum system. Ideal information transfer can be realized for some kinds of initial states. We also found that the interactions of the z-component J{sub z} and uniform magnetic field B do not have any contribution to the fidelity. These results may be useful for quantum information processing.

  6. Quantum state transfer via a two-qubit Heisenberg XXZ spin model

    International Nuclear Information System (INIS)

    Liu Jia; Zhang Guofeng; Chen Ziyu

    2008-01-01

    Transfer of quantum states through a two-qubit Heisenberg XXZ spin model with a nonuniform magnetic field b is investigated by means of quantum theory. The influences of b, the spin exchange coupling J and the effective transfer time T=Jt on the fidelity have been studied for some different initial states. Results show that fidelity of the transferred state is determined not only by J, T and b but also by the initial state of this quantum system. Ideal information transfer can be realized for some kinds of initial states. We also found that the interactions of the z-component J z and uniform magnetic field B do not have any contribution to the fidelity. These results may be useful for quantum information processing

  7. Advanced Macro-Model with Pulse-Width Dependent Switching Characteristic for Spin Transfer Torque Based Magnetic-Tunnel-Junction Elements

    Science.gov (United States)

    Sojeong Kim,; Seungjun Lee,; Hyungsoon Shin,

    2010-04-01

    In spin transfer torque (STT)-based magnetic tunnel junction (MTJ), the switching depends on the current pulse-width as well as the magnitude of the switching current. We present an advanced macro-model of an STT-MTJ for a circuit simulator such as HSPICE. The macro-model can simulate the dependence of switching behavior on current pulse-width in an STT-MTJ. An imaginary resistor-capacitor (RC) circuit is adopted to emulate complex timing behavior which cannot be described nicely by existing functions in HSPICE. Simulation results show the resistance-current (R-I) curve and timing behavior is in good agreement with the experimental data.

  8. Magnetic monopole and vector field of the spin 0

    International Nuclear Information System (INIS)

    Pantyushin, A.A.

    2001-01-01

    The motion of electrically charged particles in uniform magnetic field by time is considered. It is found out that additional force acting on eclectically charged particle from the spin 0 vector field side is proportional to the magnetic field. Proportion coefficient is equal to eg/4π (g - unknown parameter, determining of the rate and character of source non-preservation) - the analogue of constant thin structure α=e 2 /4π. Obtained results give evidence to suppose that for explanation of indicated experiments the monopole introduction is not essential

  9. Use and Misuse of Material Transfer Agreements: Lessons in Proportionality from Research, Repositories, and Litigation

    OpenAIRE

    Bubela, Tania; Guebert, Jenilee; Mishra, Amrita

    2015-01-01

    Material transfer agreements exist to facilitate the exchange of materials and associated data between researchers as well as to protect the interests of the researchers and their institutions. But this dual mandate can be a source of frustration for researchers, creating administrative burdens and slowing down collaborations. We argue here that in most cases in pre-competitive research, a simple agreement would suffice; the more complex agreements and mechanisms for their negotiation should ...

  10. Dispersion relation for localized magnetic polaritons propagating at ...

    Indian Academy of Sciences (India)

    Abstract. Localized magnetic polaritons are investigated in the systems consisting of two magnetic superlattices, coupled by a ferromagnetic contact layer. The general dis- persion relation for localized magnetic polaritons are derived in the framework of the electromagnetic wave theory in the Voigt geometry by the 'transfer' ...

  11. Transfers to hospital in planned home birth in four Nordic countries

    DEFF Research Database (Denmark)

    Blix, Ellen; Kumle, Merethe H; Ingversen, Karen

    2016-01-01

    INTRODUCTION: Women planning a home birth are transferred to hospital in case of complications or elevated risk for adverse outcomes. The aim of the present study was to describe the indications for transfer to hospital in planned home births, and the proportion of cases in which this occurs....../572) of the nulliparas were transferred to hospital, 137 (24.0%) during labor and 49 (8.6%) after the birth. Of the multiparas, 195/2446 (8.0%) were transferred, 118 (4.8%) during labor and 77 (3.2%) after birth. The most common indication for transfers during labor was slow progress. In transfers after birth...

  12. Proportioning of U3O8 powder

    International Nuclear Information System (INIS)

    Cermak, V.; Markvart, M.; Novy, P.; Vanka, M.

    1989-01-01

    The tests are briefly described or proportioning U 3 O 8 powder of a granulometric grain size range of 0-160 μm using a vertical screw, a horizontal dual screw and a vibration dispenser with a view to proportioning very fine U 3 O 8 powder fractions produced in the oxidation of UO 2 fuel pellets. In the tests, the evenness of proportioning was assessed by the percentage value of the proportioning rate spread measured at one-minute intervals at a proportioning rate of 1-3 kg/h. In feeding the U 3 O 3 in a flame fluorator, it is advantageous to monitor the continuity of the powder column being proportioned and to assess it radiometrically by the value of the proportioning rate spread at very short intervals (0.1 s). (author). 10 figs., 1 tab., 12 refs

  13. A time-varying magnetic flux concentrator

    International Nuclear Information System (INIS)

    Kibret, B; Premaratne, M; Lewis, P M; Thomson, R; Fitzgerald, P B

    2016-01-01

    It is known that diverse technological applications require the use of focused magnetic fields. This has driven the quest for controlling the magnetic field. Recently, the principles in transformation optics and metamaterials have allowed the realization of practical static magnetic flux concentrators. Extending such progress, here, we propose a time-varying magnetic flux concentrator cylindrical shell that uses electric conductors and ferromagnetic materials to guide magnetic flux to its center. Its performance is discussed based on finite-element simulation results. Our proposed design has potential applications in magnetic sensors, medical devices, wireless power transfer, and near-field wireless communications. (paper)

  14. Simulation Research of Magnetically-coupled Resonant Wireless Power Transfer System with Single Intermediate Coil Resonator Based on S Parameters Using ANSYS

    Directory of Open Access Journals (Sweden)

    Liu Cheng

    2016-01-01

    Full Text Available ANSYS can be a powerful tool to simulate the process of energy exchange in magnetically-coupled resonant wireless power transfer system. In this work, the MCR-WPT system with single intermediate coil resonator is simulated and researched based on scattering parameters using ANSYS Electromagnetics. The change rule of power transfer efficiency is reflected intuitively through the scattering parameters. A new method of calculating the coupling coefficient is proposed. A cascaded 2-port network model using scattering parameters is adopted to research the efficiency of transmission. By changing the relative position and the number of turns of the intermediate coil, we find some factors affecting the efficiency of transmission. Methods and principles of designing the MCR-WPT system with single intermediate coil resonator are obtained. And these methods have practical value with design and optimization of system efficiency.

  15. An analytical solution to the heat transfer problem in thick-walled hunt flow

    International Nuclear Information System (INIS)

    Bluck, Michael J; Wolfendale, Michael J

    2017-01-01

    Highlights: • Convective heat transfer in Hunt type flow of a liquid metal in a rectangular duct. • Analytical solution to the H1 constant peripheral temperature in a rectangular duct. • New H1 result demonstrating the enhancement of heat transfer due to flow distortion by the applied magnetic field. • Analytical solution to the H2 constant peripheral heat flux in a rectangular duct. • New H2 result demonstrating the reduction of heat transfer due to flow distortion by the applied magnetic field. • Results are important for validation of CFD in magnetohydrodynamics and for implementation of systems code approaches. - Abstract: The flow of a liquid metal in a rectangular duct, subject to a strong transverse magnetic field is of interest in a number of applications. An important application of such flows is in the context of coolants in fusion reactors, where heat is transferred to a lead-lithium eutectic. It is vital, therefore, that the heat transfer mechanisms are understood. Forced convection heat transfer is strongly dependent on the flow profile. In the hydrodynamic case, Nusselt numbers and the like, have long been well characterised in duct geometries. In the case of liquid metals in strong magnetic fields (magnetohydrodynamics), the flow profiles are very different and one can expect a concomitant effect on convective heat transfer. For fully developed laminar flows, the magnetohydrodynamic problem can be characterised in terms of two coupled partial differential equations. The problem of heat transfer for perfectly electrically insulating boundaries (Shercliff case) has been studied previously (Bluck et al., 2015). In this paper, we demonstrate corresponding analytical solutions for the case of conducting hartmann walls of arbitrary thickness. The flow is very different from the Shercliff case, exhibiting jets near the side walls and core flow suppression which have profound effects on heat transfer.

  16. Proportional Symbol Mapping in R

    Directory of Open Access Journals (Sweden)

    Susumu Tanimura

    2006-01-01

    Full Text Available Visualization of spatial data on a map aids not only in data exploration but also in communication to impart spatial conception or ideas to others. Although recent carto-graphic functions in R are rapidly becoming richer, proportional symbol mapping, which is one of the common mapping approaches, has not been packaged thus far. Based on the theories of proportional symbol mapping developed in cartography, the authors developed some functions for proportional symbol mapping using R, including mathematical and perceptual scaling. An example of these functions demonstrated the new expressive power and options available in R, particularly for the visualization of conceptual point data.

  17. Helium II heat transfer in LHC magnets : polyimide cable insulation

    NARCIS (Netherlands)

    Winkler, Tiemo

    2017-01-01

    Today’s large particle accelerators like the LHC at CERN are using superconducting materials as a construction material for magnets. These magnets need to be cooled constantly to temperatures below the critical surface of the superconducting material. In the LHC this is achieved by using liquid

  18. Design of integral magnetic field sensor

    International Nuclear Information System (INIS)

    Ma Liang; Cheng Yinhui; Wu Wei; Li Baozhong; Zhou Hui; Li Jinxi; Zhu Meng

    2010-01-01

    Magnetic field is one of the important physical parameters in the measuring process of pulsed EMP. We researched on anti-interference and high-sensitivity measurement technique of magnetic field in this report. Semi rigid cables were to bent into ringed antenna so that the antenna was shielded from electric-field interference and had little inductance; In order to have high sensitivity, operational transconductance amplifier was used to produce an active integrator; We designed an optical-electronic transferring module to upgrade anti-interference capability of the magnetic-field measurement system. A measurement system of magnetic field was accomplished. The measurement system was composed of antenna, integrator, and optical-electric transferring module and so on. We calibrated the measurement system in coaxial TEM cell. It indicates that, the measurement system's respondence of rise time is up to 2.5 ns, and output width at 90%-maximum of the pulse is wider than 200 ns. (authors)

  19. Strain-assisted current-induced magnetization reversal in magnetic tunnel junctions: A micromagnetic study with phase-field microelasticity

    International Nuclear Information System (INIS)

    Huang, H. B.; Hu, J. M.; Yang, T. N.; Chen, L. Q.; Ma, X. Q.

    2014-01-01

    Effect of substrate misfit strain on current-induced in-plane magnetization reversal in CoFeB-MgO based magnetic tunnel junctions is investigated by combining micromagnetic simulations with phase-field microelasticity theory. It is found that the critical current density for in-plane magnetization reversal decreases dramatically with an increasing substrate strain, since the effective elastic field can drag the magnetization to one of the four in-plane diagonal directions. A potential strain-assisted multilevel bit spin transfer magnetization switching device using substrate misfit strain is also proposed.

  20. Precise ion optical description of strip-line pulsed magnetic lenses

    International Nuclear Information System (INIS)

    Varentsov, D.; Spiller, P.; Eickhoff, H.; Hoffmann, D.H.H.

    2002-01-01

    A specific computer code has been developed to investigate ion optical properties of a new generation of pulsed strip-line high current magnets. The code is based on a modern 'Differential Algebra' computational technique and it is able to calculate transfer matrices of pulsed strip-line magnets up to arbitrary order. The realistic three-dimensional distribution of the magnetic field in pulsed lenses as well as all the fringing field effects are taken into account in the simulations. We have demonstrated, that for precise description of such magnets one cannot use the existing ion optical codes where ideal multipole field distributions and fringing fields, typical for conventional iron-dominated magnets are assumed. The transfer matrix elements of pulsed strip-line lenses differ significantly from those of conventional magnets, especially in higher orders

  1. Impossibility Theorem in Proportional Representation Problem

    International Nuclear Information System (INIS)

    Karpov, Alexander

    2010-01-01

    The study examines general axiomatics of Balinski and Young and analyzes existed proportional representation methods using this approach. The second part of the paper provides new axiomatics based on rational choice models. New system of axioms is applied to study known proportional representation systems. It is shown that there is no proportional representation method satisfying a minimal set of the axioms (monotonicity and neutrality).

  2. Line formation in microturbulent magnetic fields

    International Nuclear Information System (INIS)

    Domke, H.; Pavlov, G.G.

    1979-01-01

    The formation of Zeeman lines in Gaussian microturbulent magnetic fields is considered assuming LTE. General formulae are derived for the local mean values of the transfer matrix elements. The cases of one-dimensional (longitudinal), isotropic, and two-dimensional (transversal) magnetic microturbulence are studied in some detail. Asymptotic formulae are given for small mean as well as for small microturbulent magnetic fields. Characteristic effects of magnetic microturbulence on the transfer coefficients are: (i) the broadening of the frequency contours, although only for the case of longitudinal Zeeman effect and longitudinal magnetic microturbulence this effect can be described analogous to Doppler broadening, (ii) the appearance of a pseudo-Zeeman structure for nonlongitudinal magnetic microturbulence, (iii) the reduction of maximal values of circular polarization, and (iv) the appearance of characteristic linear polarization effects due to the anisotropy of the magnetic microturbulence. Line contours and polarization of Zeeman triplets are computed for Milne-Eddington atmospheres. It is shown that magnetic intensification due to microturbulent magnetic fields may be much more efficient than that due to regular fields. The gravity center of a Zeeman line observed in circularly polarized light remains a reasonable measure of the line of sight component of the mean magnetic field for a line strength eta 0 < approx. 2. For saturated lines, the gravity center distance depends significantly on the magnetic microturbulence and its anisotropy. The influence of magnetic microturbulence on the ratio of longitudinal field magnetographic signals shows that unique conclusions about the magnetic microstructure can be drawn from the line ratio measurements only in combination with further spectroscopic data or physical reasoning. (orig.)

  3. Optimization of output power and transmission efficiency of magnetically coupled resonance wireless power transfer system

    Science.gov (United States)

    Yan, Rongge; Guo, Xiaoting; Cao, Shaoqing; Zhang, Changgeng

    2018-05-01

    Magnetically coupled resonance (MCR) wireless power transfer (WPT) system is a promising technology in electric energy transmission. But, if its system parameters are designed unreasonably, output power and transmission efficiency will be low. Therefore, optimized parameters design of MCR WPT has important research value. In the MCR WPT system with designated coil structure, the main parameters affecting output power and transmission efficiency are the distance between the coils, the resonance frequency and the resistance of the load. Based on the established mathematical model and the differential evolution algorithm, the change of output power and transmission efficiency with parameters can be simulated. From the simulation results, it can be seen that output power and transmission efficiency of the two-coil MCR WPT system and four-coil one with designated coil structure are improved. The simulation results confirm the validity of the optimization method for MCR WPT system with designated coil structure.

  4. Increasing transfers-out from an antiretroviral treatment service in South Africa: patient characteristics and rates of virological non-suppression.

    Directory of Open Access Journals (Sweden)

    Mweete D Nglazi

    Full Text Available To determine the proportion, characteristics and outcomes of patients who transfer-out from an antiretroviral therapy (ART service in a South African township.This retrospective cohort study included all patients aged ≥15 years who enrolled between September 2002 and December 2009. Follow-up data were censored in December 2010. Kaplan-Meier survival analysis was used to describe time to transfer-out and cox proportional hazard analysis was used to determine associated risk factors.4511 patients (4003 ART-naïve and 508 non-naïve at baseline received ART during the study period. Overall, 597 (13.2% transferred out. The probability of transferring out by one year of ART steadily increased from 1.4% in 2002/2004 cohort to 8.9% for the 2009 cohort. Independent risk factors for transfer-out were more recent calendar year of enrolment, younger age (≤25 years and being ART non-naïve at baseline (i.e., having previously transferred into this clinic from another facility. The proportions of patients transferred out who had a CD4 cell count 1000 copies/mL around the time of transfer, suggesting the need for careful adherence counseling and assessment of medication supplies among those planning transfer.

  5. Surface molecular imprinting onto fluorescein-coated magnetic nanoparticlesvia reversible addition fragmentation chain transfer polymerization: A facile three-in-one system for recognition and separation of endocrine disrupting chemicals

    Science.gov (United States)

    Li, Ying; Dong, Cunku; Chu, Jia; Qi, Jingyao; Li, Xin

    2011-01-01

    In this study, we present a general protocol for the making of surface-imprinted magnetic fluorescence beads viareversible addition-fragmentation chain transfer polymerization. The resulting composites were characterized by X-ray diffraction analysis, transmission electron microscopy, scanning electron microscopy, fluorescence spectroscopy, Fourier transform infrared spectroscopy, and energy dispersive spectroscopy. The as-synthesized beads exhibited homogeneous polymer films (thickness of about 5.7 nm), spherical shape, high fluorescence intensity and magnetic property (Magnetization (Ms) = 3.67 emu g-1). The hybrids bind the original template 17β-estradiol with an appreciable selectivity over structurally related compounds. In addition, the resulting hybrids performed without obvious deterioration after five repeated cycles. This study therefore demonstrates the potential of molecularly imprinted polymers for the recognition and separation of endocrine disrupting chemicals.In this study, we present a general protocol for the making of surface-imprinted magnetic fluorescence beads viareversible addition-fragmentation chain transfer polymerization. The resulting composites were characterized by X-ray diffraction analysis, transmission electron microscopy, scanning electron microscopy, fluorescence spectroscopy, Fourier transform infrared spectroscopy, and energy dispersive spectroscopy. The as-synthesized beads exhibited homogeneous polymer films (thickness of about 5.7 nm), spherical shape, high fluorescence intensity and magnetic property (Magnetization (Ms) = 3.67 emu g-1). The hybrids bind the original template 17β-estradiol with an appreciable selectivity over structurally related compounds. In addition, the resulting hybrids performed without obvious deterioration after five repeated cycles. This study therefore demonstrates the potential of molecularly imprinted polymers for the recognition and separation of endocrine disrupting chemicals. Electronic

  6. Magnet costs for the Advanced Light Source

    International Nuclear Information System (INIS)

    Tanabe, J.; Krupnick, J.; Hoyer, E.; Paterson, A.

    1993-05-01

    The Advanced Light Source (ALS) accelerator is now completed. The numerous conventional magnets required for the booster ring, the storage ring and the low and high energy transfer lines were installed during the last two years. This paper summarizes the various costs associated with the quantity fabrication of selected magnet families. These costs include the costs of prototypes, tooling, coil and core fabrication, assembly and magnetic measurements. Brief descriptions of the magnets and specialized requirements for magnetic measurements are included in order to associate the costs with the relative complexities of the various magnet systems

  7. The characteristic of evaporative cooling magnet for ECRIS

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, B., E-mail: xiongbin@mail.iee.ac.cn [Institute of Electrical Engineering, CAS, Beijing 100190 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Ruan, L.; Gu, G. B. [Institute of Electrical Engineering, CAS, Beijing 100190 (China); Lu, W.; Zhang, X. Z.; Zhan, W. L. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 73000 (China)

    2016-02-15

    Compared with traditional de-ionized pressurized-water cooled magnet of ECRIS, evaporative cooling magnet has some special characteristics, such as high cooling efficiency, simple maintenance, and operation. The analysis is carried out according to the design and operation of LECR4 (Lanzhou Electron Cyclotron Resonance ion source No. 4, since July 2013), whose magnet is cooled by evaporative cooling technology. The insulation coolant replaces the de-ionized pressurized-water to absorb the heat of coils, and the physical and chemical properties of coolant remain stable for a long time with no need for purification or filtration. The coils of magnet are immersed in the liquid coolant. For the higher cooling efficiency of coolant, the current density of coils can be greatly improved. The heat transfer process executes under atmospheric pressure, and the temperature of coils is lower than 70 °C when the current density of coils is 12 A/mm{sup 2}. On the other hand, the heat transfer temperature of coolant is about 50 °C, and the heat can be transferred to fresh air which can save cost of water cooling system. Two years of LECR4 stable operation show that evaporative cooling technology can be used on magnet of ECRIS, and the application advantages are very obvious.

  8. The characteristic of evaporative cooling magnet for ECRIS

    Science.gov (United States)

    Xiong, B.; Ruan, L.; Gu, G. B.; Lu, W.; Zhang, X. Z.; Zhan, W. L.

    2016-02-01

    Compared with traditional de-ionized pressurized-water cooled magnet of ECRIS, evaporative cooling magnet has some special characteristics, such as high cooling efficiency, simple maintenance, and operation. The analysis is carried out according to the design and operation of LECR4 (Lanzhou Electron Cyclotron Resonance ion source No. 4, since July 2013), whose magnet is cooled by evaporative cooling technology. The insulation coolant replaces the de-ionized pressurized-water to absorb the heat of coils, and the physical and chemical properties of coolant remain stable for a long time with no need for purification or filtration. The coils of magnet are immersed in the liquid coolant. For the higher cooling efficiency of coolant, the current density of coils can be greatly improved. The heat transfer process executes under atmospheric pressure, and the temperature of coils is lower than 70 °C when the current density of coils is 12 A/mm2. On the other hand, the heat transfer temperature of coolant is about 50 °C, and the heat can be transferred to fresh air which can save cost of water cooling system. Two years of LECR4 stable operation show that evaporative cooling technology can be used on magnet of ECRIS, and the application advantages are very obvious.

  9. United States Superconducting MHD Magnet Technology Development Program

    International Nuclear Information System (INIS)

    Dawson, A.M.; Marston, P.G.; Thome, R.J.; Iwasa, Y.; Tarrh, J.M.

    1981-01-01

    A three-faceted program supported by the U.S. Dep of Energy is described. These facets include basic technology development, technology transfer and construction by industry of magnets for the national MHD program. The program includes the maintenance of a large component test facility; investigation of superconductor stability and structural behavior; measurements of materials' properties at low temperatures; structural design optimization; analytical code development; cryogenic systems and power supply design. The technology transfer program is designed to bring results of technology development and design and construction effort to the entire superconducting magnet community. The magnet procurement program is responsible for developing conceptual designs of magnets needed for the national MHD program, for issuing requests for quotation, selecting vendors and supervising design, construction, installation and test of these systems. 9 refs

  10. Proportioning of light weight concrete

    DEFF Research Database (Denmark)

    Palmus, Lars

    1996-01-01

    Development of a method to determine the proportions of the raw materials in light weight concrete made with leight expanded clay aggregate. The method is based on composite theory......Development of a method to determine the proportions of the raw materials in light weight concrete made with leight expanded clay aggregate. The method is based on composite theory...

  11. Analysis and design of permanent magnet biased magnetic bearing based on hybrid factor

    Directory of Open Access Journals (Sweden)

    Jinji Sun

    2016-03-01

    Full Text Available In this article, hybrid factor is proposed for hybrid magnetic bearing. The hybrid factor is defined as the ratio of the force produced by the permanent magnet and the forces produced by the permanent magnet and current in hybrid magnetic bearing. It is deduced from a certain radial hybrid magnetic bearing using its important parameters such as the current stiffness and displacement stiffness at first and then the dynamic model of magnetically suspended rotor system is established. The relationship between structural parameters and control system parameters is analyzed based on the hybrid factor. Some influencing factors of hybrid factor in hybrid magnetic bearing, such as the size of the permanent magnet, length of air gap, and area of the stator poles, are analyzed in this article. It can be concluded that larger hybrid factor can be caused by the smaller power loss according to the definition of hybrid factor mentioned above. Meanwhile, the hybrid factor has a maximum value, which is related to control system parameters such as proportional factor expect for structural parameters. Finally, the design steps of parameters of hybrid magnetic bearing can be concluded.

  12. Advanced Active-Magnetic-Bearing Thrust-Measurement System

    Science.gov (United States)

    Imlach, Joseph; Kasarda, Mary; Blumber, Eric

    2008-01-01

    An advanced thrust-measurement system utilizes active magnetic bearings to both (1) levitate a floating frame in all six degrees of freedom and (2) measure the levitation forces between the floating frame and a grounded frame. This system was developed for original use in measuring the thrust exerted by a rocket engine mounted on the floating frame, but can just as well be used in other force-measurement applications. This system offers several advantages over prior thrust-measurement systems based on mechanical support by flexures and/or load cells: The system includes multiple active magnetic bearings for each degree of freedom, so that by selective use of one, some, or all of these bearings, it is possible to test a given article over a wide force range in the same fixture, eliminating the need to transfer the article to different test fixtures to obtain the benefit of full-scale accuracy of different force-measurement devices for different force ranges. Like other active magnetic bearings, the active magnetic bearings of this system include closed-loop control subsystems, through which the stiffness and damping characteristics of the magnetic bearings can be modified electronically. The design of the system minimizes or eliminates cross-axis force-measurement errors. The active magnetic bearings are configured to provide support against movement along all three orthogonal Cartesian axes, and such that the support along a given axis does not produce force along any other axis. Moreover, by eliminating the need for such mechanical connections as flexures used in prior thrust-measurement systems, magnetic levitation of the floating frame eliminates what would otherwise be major sources of cross-axis forces and the associated measurement errors. Overall, relative to prior mechanical-support thrust-measurement systems, this system offers greater versatility for adaptation to a variety of test conditions and requirements. The basic idea of most prior active-magnetic

  13. Deep gray matter demyelination detected by magnetization transfer ratio in the cuprizone model.

    Directory of Open Access Journals (Sweden)

    Sveinung Fjær

    Full Text Available In multiple sclerosis (MS, the correlation between lesion load on conventional magnetic resonance imaging (MRI and clinical disability is weak. This clinico-radiological paradox might partly be due to the low sensitivity of conventional MRI to detect gray matter demyelination. Magnetization transfer ratio (MTR has previously been shown to detect white matter demyelination in mice. In this study, we investigated whether MTR can detect gray matter demyelination in cuprizone exposed mice. A total of 54 female C57BL/6 mice were split into one control group ( and eight cuprizone exposed groups ([Formula: see text]. The mice were exposed to [Formula: see text] (w/w cuprizone for up to six weeks. MTR images were obtained at a 7 Tesla Bruker MR-scanner before cuprizone exposure, weekly for six weeks during cuprizone exposure, and once two weeks after termination of cuprizone exposure. Immunohistochemistry staining for myelin (anti-Proteolopid Protein and oligodendrocytes (anti-Neurite Outgrowth Inhibitor Protein A was obtained after each weekly scanning. Rates of MTR change and correlations between MTR values and histological findings were calculated in five brain regions. In the corpus callosum and the deep gray matter a significant rate of MTR value decrease was found, [Formula: see text] per week ([Formula: see text] and [Formula: see text] per week ([Formula: see text] respectively. The MTR values correlated to myelin loss as evaluated by immunohistochemistry (Corpus callosum: [Formula: see text]. Deep gray matter: [Formula: see text], but did not correlate to oligodendrocyte density. Significant results were not found in the cerebellum, the olfactory bulb or the cerebral cortex. This study shows that MTR can be used to detect demyelination in the deep gray matter, which is of particular interest for imaging of patients with MS, as deep gray matter demyelination is common in MS, and is not easily detected on conventional clinical MRI.

  14. Investigations on magnetic field induced optical transparency in magnetic nanofluids

    Science.gov (United States)

    Mohapatra, Dillip Kumar; Philip, John

    2018-02-01

    We study the magnetic field induced optical transparency and its origin in magnetic nanoemulsion of droplets of average size ∼200 nm containing superparamagnetic iron oxide nanoparticles. Beyond a certain volume fraction (Φ > 0.0021) of magnetic nanoemulsion and a critical magnetic field (Hc1), the transmitted light intensity increases drastically and reaches a maximum at another critical magnetic field (Hc2), beyond which the transmitted light intensity decreases and reaches a plateau. Interestingly, the transmitted light intensity at Hc2 is found to increase linearly with Φ and the critical magnetic fields Hc1 and Hc2 follow power law decay with Φ (i.e. Hc ∼ Φ-x), with exponents 0.48 and 0.27, respectively. The light intensity recovers to its initial value when the magnetic field is switched off, indicating the perfect reversibility of the field induced transparency process. The observed straight line scattered patterns above Hc2, on a screen placed perpendicular to the incident beam, confirms the formation of rod like anisotropic nanostructures perpendicular to the direction of light propagation. The magneto-optical measurements in the emulsion confirm that the observed field induced transparency in magnetic emulsions for Φ > 0.0021 is due to the optical birefringence caused by the rod like nanostructures. The reduced birefringence is found to be proportional to the square of the applied magnetic field. This finding offers several possibilities in using magnetic nanofluids in tunable optical devices.

  15. Magnetic forces and magnetized biomaterials provide dynamic flux information during bone regeneration.

    Science.gov (United States)

    Russo, Alessandro; Bianchi, Michele; Sartori, Maria; Parrilli, Annapaola; Panseri, Silvia; Ortolani, Alessandro; Sandri, Monica; Boi, Marco; Salter, Donald M; Maltarello, Maria Cristina; Giavaresi, Gianluca; Fini, Milena; Dediu, Valentin; Tampieri, Anna; Marcacci, Maurilio

    2016-03-01

    The fascinating prospect to direct tissue regeneration by magnetic activation has been recently explored. In this study we investigate the possibility to boost bone regeneration in an experimental defect in rabbit femoral condyle by combining static magnetic fields and magnetic biomaterials. NdFeB permanent magnets are implanted close to biomimetic collagen/hydroxyapatite resorbable scaffolds magnetized according to two different protocols . Permanent magnet only or non-magnetic scaffolds are used as controls. Bone tissue regeneration is evaluated at 12 weeks from surgery from a histological, histomorphometric and biomechanical point of view. The reorganization of the magnetized collagen fibers under the effect of the static magnetic field generated by the permanent magnet produces a highly-peculiar bone pattern, with highly-interconnected trabeculae orthogonally oriented with respect to the magnetic field lines. In contrast, only partial defect healing is achieved within the control groups. We ascribe the peculiar bone regeneration to the transfer of micro-environmental information, mediated by collagen fibrils magnetized by magnetic nanoparticles, under the effect of the static magnetic field. These results open new perspectives on the possibility to improve implant fixation and control the morphology and maturity of regenerated bone providing "in site" forces by synergically combining static magnetic fields and biomaterials.

  16. Static magnetic field reduced exogenous oligonucleotide uptake by spermatozoa using magnetic nanoparticle gene delivery system

    International Nuclear Information System (INIS)

    Katebi, Samira; Esmaeili, Abolghasem; Ghaedi, Kamran

    2016-01-01

    Spermatozoa could introduce exogenous oligonucleotides of interest to the oocyte. The most important reason of low efficiency of sperm mediated gene transfer (SMGT) is low uptake of exogenous DNA by spermatozoa. The aim of this study was to evaluate the effects of static magnetic field on exogenous oligonucleotide uptake of spermatozoa using magnetofection method. Magnetic nanoparticles (MNPs) associated with the labeled oligonucleotides were used to increase the efficiency of exogenous oligonucleotide uptake by rooster spermatozoa. We used high-field/high-gradient magnet (NdFeB) to enhance and accelerate exogenous DNA sedimentation at the spermatozoa surface. Flow cytometry analysis was performed to measure viability and percentage of exogenous oligonucleotide uptake by sperm. Flow cytometry analysis showed a significant increase in exogenous oligonucleotide uptake by rooster spermatozoa (P<0.001) when spermatozoa were incubated in exogenous oligonucleotide solution and MNPs. However, by applying static magnetic field during magnetofection method, a significant decrease in exogenous oligonucleotide uptake was observed (P<0.05). Findings of this study showed that MNPs were effective to increase exogenous oligonucleotide uptake by rooster spermatozoa; however unlike others studies, static magnetic field, was not only ineffective to enhance exogenous oligonucleotide uptake by rooster spermatozoa but also led to reduction in efficiency of magnetic nanoparticles in gene transfer. - Highlights: • Core/shell type Iron oxide nanoparticles were used as a novel and efficient method. • This method increases exogenous DNA uptake by rooster spermatozoa. • Static magnetic field decreased DNA uptake by rooster spermatozoa.

  17. Static magnetic field reduced exogenous oligonucleotide uptake by spermatozoa using magnetic nanoparticle gene delivery system

    Energy Technology Data Exchange (ETDEWEB)

    Katebi, Samira; Esmaeili, Abolghasem, E-mail: aesmaeili@sci.ui.ac.ir; Ghaedi, Kamran

    2016-03-15

    Spermatozoa could introduce exogenous oligonucleotides of interest to the oocyte. The most important reason of low efficiency of sperm mediated gene transfer (SMGT) is low uptake of exogenous DNA by spermatozoa. The aim of this study was to evaluate the effects of static magnetic field on exogenous oligonucleotide uptake of spermatozoa using magnetofection method. Magnetic nanoparticles (MNPs) associated with the labeled oligonucleotides were used to increase the efficiency of exogenous oligonucleotide uptake by rooster spermatozoa. We used high-field/high-gradient magnet (NdFeB) to enhance and accelerate exogenous DNA sedimentation at the spermatozoa surface. Flow cytometry analysis was performed to measure viability and percentage of exogenous oligonucleotide uptake by sperm. Flow cytometry analysis showed a significant increase in exogenous oligonucleotide uptake by rooster spermatozoa (P<0.001) when spermatozoa were incubated in exogenous oligonucleotide solution and MNPs. However, by applying static magnetic field during magnetofection method, a significant decrease in exogenous oligonucleotide uptake was observed (P<0.05). Findings of this study showed that MNPs were effective to increase exogenous oligonucleotide uptake by rooster spermatozoa; however unlike others studies, static magnetic field, was not only ineffective to enhance exogenous oligonucleotide uptake by rooster spermatozoa but also led to reduction in efficiency of magnetic nanoparticles in gene transfer. - Highlights: • Core/shell type Iron oxide nanoparticles were used as a novel and efficient method. • This method increases exogenous DNA uptake by rooster spermatozoa. • Static magnetic field decreased DNA uptake by rooster spermatozoa.

  18. The swimming polarity of multicellular magnetotactic prokaryotes can change during an isolation process employing magnets: evidence of a relation between swimming polarity and magnetic moment intensity.

    Science.gov (United States)

    de Melo, Roger Duarte; Acosta-Avalos, Daniel

    2017-09-01

    Magnetotactic microorganisms are characterized by swimming in the direction of an applied magnetic field. In nature, two types of swimming polarity have been observed: north-seeking microorganisms that swim in the same direction as the magnetic field, and south-seeking microorganisms that swim in the opposite direction. The present work studies the reversal in the swimming polarity of the multicellular magnetotactic prokaryote Candidatus Magnetoglobus multicellularis following an isolation process using high magnetic fields from magnets. The proportion of north- and south-seeking organisms was counted as a function of the magnetic field intensity used during the isolation of the organisms from sediment. It was observed that the proportion of north-seeking organisms increased when the magnetic field was increased. The magnetic moment for north- and south-seeking populations was estimated using the U-turn method. The average magnetic moment was higher for north- than south-seeking organisms. The results suggest that the reversal of swimming polarity must occur during the isolation process in the presence of high magnetic fields and magnetic field gradients. It is shown for the first time that the swimming polarity reversal depends on the magnetic moment intensity of multicellular magnetotactic prokaryotes, and new studies must be undertaken to understand the role of magnetic moment polarity and oxygen gradients in determination of swimming polarity.

  19. ULF-NMR system using HTS-SQUID and permanent magnet

    Energy Technology Data Exchange (ETDEWEB)

    Fukumoto, Shohei, E-mail: hatukade@ens.tut.ac.jp [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan); Tsunaki, Shingo; Chigasaki, Takumi; Hatsukade, Yoshimi; Tanaka, Saburo [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2013-01-15

    Highlights: ► A permanent magnet was introduced into a ULF SQUID-NMR system for polarization. ► An instrument to transfer a sample in the magnet to under a SQUID was implemented. ► An AC pulse coil was also introduced to apply a π/2 pulse to obtain an NMR signal. ► A {sup 1}H NMR signal was measured while applying a static field of 45 μT. ► The signal to noise ratio of the {sup 1}H NMR signal was about 100. -- Abstract: We have constructed an ultra-low field (ULF) nuclear magnetic resonance (NMR)/magnetic resonance imaging (MRI) system using an HTS-rf-SQUID and room-temperature electromagnets in a magnetically shielded room (MSR). In this study, in order to improve the signal to noise ratio (S/N) of the system, we introduced a permanent magnet instead of the electromagnet for pre-polarizing the sample to enhance the pre-polarizing field (B{sub p}). The cylindrical permanent magnet of 270 mT was used to magnetize a water sample for several seconds outside the MSR and about 1.5 m away from the SQUID. We constructed an instrument to transfer the magnetized sample from the permanent magnet to under the SQUID in 0.5 s. Since the non-adiabatic condition cannot be kept in such sample transfer scheme, an AC pulse coil to apply an AC pulse field B{sub AC} to rotate the magnetization moments for π/2 was introduced to measure a free induction decay (FID) signal from the sample. By this system, we obtained an NMR signal from the water sample of 10 ml while applying a static field of 45 μT and π/2 pulse after the transfer. The S/N of the NMR spectrum was about 100 by a single shot, which was 10 times larger than that obtained with the electromagnet of 32 mT. In addition, we demonstrated the measurements of the longitudinal relaxation time (T{sub 1}) and the spin echo signal of the water sample by the system.

  20. Quantum size effects on spin-transfer torque in a double barrier magnetic tunnel junction with a nonmagnetic-metal (semiconductor) spacer

    International Nuclear Information System (INIS)

    Daqiq, Reza; Ghobadi, Nader

    2016-01-01

    We study the quantum size effects of an MgO-based double barrier magnetic tunnel junction with a nonmagnetic-metal (DBMTJ-NM) (semiconductor (DBMTJ-SC)) spacer on the charge current and the spin-transfer torque (STT) components using non-equilibrium Green's function (NEGF) formalism. The results show oscillatory behavior due to the resonant tunneling effect depending on the structure parameters. We find that the charge current and the STT components in the DBMTJ-SC demonstrate the magnitude enhancement in comparison with the DBMTJ-NM. The bias dependence of the STT components in a DBMTJ-NM shows different behavior in comparison with spin valves and conventional MTJs. Therefore, by choosing a specific SC spacer with suitable thickness in a DBMTJ the charge current and the STT components significantly increase so that one can design a device with high STT and faster magnetization switching. - Highlights: • The quantum size effects are studied in double barrier magnetic tunnel junctions. • Spin torque (ST) components oscillate for increasing of middle spacer thicknesses. • Due to the resonant tunneling in the quantum well, oscillations have appeared. • By replacement a metal spacer with a semiconductor (ZnO) ST has increased. • The ST components vs. bias show gradually decreasing unlike spin valves or MTJs.

  1. Quantum size effects on spin-transfer torque in a double barrier magnetic tunnel junction with a nonmagnetic-metal (semiconductor) spacer

    Energy Technology Data Exchange (ETDEWEB)

    Daqiq, Reza; Ghobadi, Nader

    2016-07-15

    We study the quantum size effects of an MgO-based double barrier magnetic tunnel junction with a nonmagnetic-metal (DBMTJ-NM) (semiconductor (DBMTJ-SC)) spacer on the charge current and the spin-transfer torque (STT) components using non-equilibrium Green's function (NEGF) formalism. The results show oscillatory behavior due to the resonant tunneling effect depending on the structure parameters. We find that the charge current and the STT components in the DBMTJ-SC demonstrate the magnitude enhancement in comparison with the DBMTJ-NM. The bias dependence of the STT components in a DBMTJ-NM shows different behavior in comparison with spin valves and conventional MTJs. Therefore, by choosing a specific SC spacer with suitable thickness in a DBMTJ the charge current and the STT components significantly increase so that one can design a device with high STT and faster magnetization switching. - Highlights: • The quantum size effects are studied in double barrier magnetic tunnel junctions. • Spin torque (ST) components oscillate for increasing of middle spacer thicknesses. • Due to the resonant tunneling in the quantum well, oscillations have appeared. • By replacement a metal spacer with a semiconductor (ZnO) ST has increased. • The ST components vs. bias show gradually decreasing unlike spin valves or MTJs.

  2. Cash social transfers, direct taxes, and income distribution in late socialism

    OpenAIRE

    Milanovic, Branko

    1993-01-01

    The author analyzes the impact of direct taxes and cash social transfers on income distribution in Bulgaria, Czechoslovakia, Hungary, Poland and Yugoslavia in the years before the collapse of communism. He contrasts the results for socialist and market economies. Cash social transfers accounted for about a fifth of gross income, a proportion comparable with that in developed welfare economies. Generally, cash transfers were unrelated to income in socialist countries, in marked contrast with m...

  3. Development of multiwire proportional chambers

    CERN Multimedia

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  4. Elaboration And Study Of Transfer Alanine/ESR Dosemeters

    International Nuclear Information System (INIS)

    Torres G, Luz A.

    1996-01-01

    The dosimetry is the dose measure imparted by the energy from the ionizing radiation to the matter. The dosemeters is the means used for the determination of such a dose. Diverse dosimetric classes exist, this classification depends in essence of the energy involved in the irradiation process and of its application necessity. It is as well as in radiological protection movie dosemeter is used, and TLD, in the calibration of units, as those of cobalt, the ionization cameras are used, in the detection of superficial contamination the accountants Geiger Muller and proportional etc. The transfer dosimeter Alanine/ESR is used, object of the present work, is characterized because after reading the registered dose, the information is conserved and it can be transferred and read in any team of ESR. Likewise the following dose that is imparted will be added to the previous one registered, this indicates that the dosemeters is of integral character. In the spectra taken ESR, it is determined that the integral double or area under the curve of the spectrum ESR is proportional to the concentration of free radicals generated by the radiation ionization and in turn this concentration is proportional to the dose received by the pills; in last, these proportionality relationships take to that the area under the curve of the spectrum main ESR is proportional to the radiation dose received by the alanine dosemeters. This dosemeter seeks to be an economic alternative that it will lend the calibration service that today offers the ionization Cameras or the acrylic red industrial dosemeters

  5. A Three-Component Model for Magnetization Transfer. Solution by Projection-Operator Technique, and Application to Cartilage

    Science.gov (United States)

    Adler, Ronald S.; Swanson, Scott D.; Yeung, Hong N.

    1996-01-01

    A projection-operator technique is applied to a general three-component model for magnetization transfer, extending our previous two-component model [R. S. Adler and H. N. Yeung,J. Magn. Reson. A104,321 (1993), and H. N. Yeung, R. S. Adler, and S. D. Swanson,J. Magn. Reson. A106,37 (1994)]. The PO technique provides an elegant means of deriving a simple, effective rate equation in which there is natural separation of relaxation and source terms and allows incorporation of Redfield-Provotorov theory without any additional assumptions or restrictive conditions. The PO technique is extended to incorporate more general, multicomponent models. The three-component model is used to fit experimental data from samples of human hyaline cartilage and fibrocartilage. The fits of the three-component model are compared to the fits of the two-component model.

  6. Optimization of transfer of laser-cooled atom cloud to a quadrupole ...

    Indian Academy of Sciences (India)

    2014-02-08

    Feb 8, 2014 ... We present here our experimental results on transfer of laser-cooled atom cloud to a quadrupole magnetic trap. We show that by choosing appropriately the ratio of potential energy in magnetic trap to kinetic energy of cloud in molasses, we can obtain the maximum phase-space density in the magnetic trap.

  7. Transferability of habitat suitability criteria for fishes in warmwater streams

    Science.gov (United States)

    Freeman, Mary C.; Bowen, Z.H.; Crance, J.H.

    1997-01-01

    We developed habitat suitability criteria and tested their transferability for nine fishes inhabiting unregulated Piedmont and Coastal Plain streams in Alabama. Cr iteria for optimal habitat were defined as ranges of depth, velocity, substrate type and cover type for which a species' suitability index (proportional abundance divided by proportional habitat availability, scaled from 0 to 1) equalled or exceeded 0.4. We evaluated the transferability of criteria between study sites by testing the null hypothesis that species occurrence in a sample was independent of whether or not the sample was taken in optimal habitat. We also tested criteria transference to a large, flow-regulated river sampled during low flow periods. Depth, velocity and most substrate criteria developed for the bronze darter Percina palmaris successfully transferred between unregulated streams and to the flow-regulated river samples. All criteria developed for a pair of closely related, allopatric darter species, Etheostoma chuckwachattee and E. jordani, transferred sucessfully when applied between species (in the unregulated sites) and to the regulated river samples. In contrast, criteria for the Alabama shiner Cyprinella callistia failed nearly all tests of transferability. Criteria for E. stigmaeum, P. nigrofasciata, an undescribed Percina species, and a pair of related, allopatric Cyprinella species transferred inconsistently. The species with good criteria transference had high suitability indices for shallow depths, fast current velocities and coarse substrates, characteristic of riffle species. We suggest that microhabitat criteria for riffle fishes are more likely to provide a transferable measure of habitat quality than criteria for fishes that, although restricted to fluvial habitats, commonly occupy a variety of pool and riffle habitats.

  8. Use and misuse of material transfer agreements: lessons in proportionality from research, repositories, and litigation.

    Science.gov (United States)

    Bubela, Tania; Guebert, Jenilee; Mishra, Amrita

    2015-02-01

    Material transfer agreements exist to facilitate the exchange of materials and associated data between researchers as well as to protect the interests of the researchers and their institutions. But this dual mandate can be a source of frustration for researchers, creating administrative burdens and slowing down collaborations. We argue here that in most cases in pre-competitive research, a simple agreement would suffice; the more complex agreements and mechanisms for their negotiation should be reserved for cases where the risks posed to the institution and the potential commercial value of the research reagents is high.

  9. Core/Shell Structured Magnetic Nanoparticles for Biological Applications

    International Nuclear Information System (INIS)

    Park, Jeong Chan; Jung, Myung Hwan

    2013-01-01

    Magnetic nanoparticles have been widely used for biomedical applications, such as magnetic resonance imaging (MRI), hyperthermia, drug delivery and cell signaling. The surface modification of the nanomaterials is required for biomedical use to give physiogical stability, surface reactivity and targeting properties. Among many approaches for the surface modification with materials, such as polymers, organic ligands and metals, one of the most attractive ways is using metals. The fabrication of metal-based, monolayer-coated magnetic nanoparticles has been intensively studied. However, the synthesis of metal-capped magnetic nanoparticles with monodispersities and controllable sizes is still challenged. Recently, gold-capped magnetic nanoparticles have been reported to increase stability and to provide biocompatibility. Magnetic nanoparticle with gold coating is an attractive system, which can be stabilized in biological conditions and readily functionalized in biological conditions and readily functionalized through well-established surface modification (Au-S) chemistry. The Au coating offers plasmonic properties to magnetic nanoparticles. This makes the magnetic/Au core/shell combinations interesting for magnetic and optical applications. Herein, the synthesis and characterization of gold capped-magnetic core structured nanomaterials with different gold sources, such as gold acetate and chloroauric acid have been reported. The core/shell nanoparticles were transferred from organic to aqueous solutions for biomedical applications. Magnetic core/shell structured nanoparticles have been prepared and transferred from organic phase to aqueous solutions. The resulting Au-coated magnetic core nanoparticles might be an attractive system for biomedical applications, which are needed both magnetic resonance imaging and optical imaging

  10. Small-polaron formation and motion in magnetic semiconductors

    International Nuclear Information System (INIS)

    Emin, D.

    1979-01-01

    The fundamental physical processes associated with small-polaron formation are described with various magnetic semi-conductors being cited as examples. Attention is then directed toward the mechanisms of charge transfer and small-polaron hopping motion in magnetic semiconductors

  11. Coherent and semi-coherent neutron transfer reactions

    International Nuclear Information System (INIS)

    Hagelstein, P.L.

    1992-01-01

    Neutron transfer reactions are proposed to account for anomalies reported in Pons-Fleischmann experiments. The prototypical reaction involves the transfer of a neutron (mediated by low frequency electric or magnetic fields) from a donor nucleus to virtual continuum states, followed by the capture of the virtual neutron by an acceptor nucleus. In this work we summarize basic principles, recent results and the ultimate goals of the theoretical effort

  12. Coherent and semi-coherent neutron transfer reactions

    International Nuclear Information System (INIS)

    Hagelstein, P.L.

    1993-01-01

    Neutron transfer reactions are proposed to account for anomalies reported in Pons-Fleischmann experiments. The prototypical reaction involves the transfer of a neutron (mediated by low frequency electric or magnetic fields) from a donor nucleus to virtual continuum states, followed by the capture of the virtual neutron by an acceptor nucleus. In this work we summarize basic principles, recent results and the ultimate goals of the theoretical effort. (author)

  13. Out-of-plane spin-transfer torques: First-principles study

    Czech Academy of Sciences Publication Activity Database

    Carva, K.; Turek, Ilja

    2010-01-01

    Roč. 322, 9-12 (2010), s. 1085-1087 ISSN 0304-8853. [Joint European Magnetic Symposia /4./. Dublin, 14.09.2008-19.09.2008] Institutional research plan: CEZ:AV0Z20410507 Keywords : spin-transfer torque * spin-mixing conductance Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.689, year: 2010

  14. Splitter magnets for DAΦNE project

    International Nuclear Information System (INIS)

    Sanelli, C.; Hsieh, H.

    1992-01-01

    A 510 MeV electron positron colliding beam facility is under design and construction. The project consists of two storage rings, accumulator, electron/positron linac and transfer lines. The design of the splitter magnets which separate the circulating beams immediately after passing through the DAΦNE interaction point is presented. The results of 2-D and 3-D magnetic calculations is presented, and the electrical and mechanical design of the magnet are described. A 1/3 length prototype of this magnet is under construction. (R.P.) 2 refs.; 8 figs.; 2 tabs

  15. Controllable manipulation of superconductivity using magnetic vortices

    International Nuclear Information System (INIS)

    Villegas, J E; Schuller, Ivan K

    2011-01-01

    The magneto-transport of a superconducting/ferromagnetic hybrid structure, consisting of a superconducting thin film in contact with an array of magnetic nanodots in the so-called 'magnetic vortex state', exhibits interesting properties. For certain magnetic states, the stray magnetic field from the vortex array is intense enough to drive the superconducting film into the normal state. In this fashion, the normal-to-superconducting phase transition can be controlled by the magnetic history. The strong coupling between superconducting and magnetic subsystems allows characteristically ferromagnetic properties, such as hysteresis and remanence, to be dramatically transferred into the transport properties of the superconductor.

  16. Conjugate Image Theory Applied on Capacitive Wireless Power Transfer

    OpenAIRE

    Ben Minnaert; Nobby Stevens

    2017-01-01

    Wireless power transfer using a magnetic field through inductive coupling is steadily entering the market in a broad range of applications. However, for certain applications, capacitive wireless power transfer using electric coupling might be preferable. In order to obtain a maximum power transfer efficiency, an optimal compensation network must be designed at the input and output ports of the capacitive wireless link. In this work, the conjugate image theory is applied to determine this opti...

  17. The magnetic-nanofluid heat pipe with superior thermal properties through magnetic enhancement

    Science.gov (United States)

    2012-01-01

    This study developed a magnetic-nanofluid (MNF) heat pipe (MNFHP) with magnetically enhanced thermal properties. Its main characteristic was additional porous iron nozzle in the evaporator and the condenser to form a unique flowing pattern of MNF slug and vapor, and to magnetically shield the magnet attraction on MNF flowing. The results showed that an optimal thermal conductivity exists in the applied field of 200 Oe. Furthermore, the minor thermal performance of MNF at the condenser limited the thermal conductivity of the entire MNFHP, which was 1.6 times greater than that filled with water for the input power of 60 W. The feasibilities of an MNFHP with the magnetically enhanced heat transfer and the ability of vertical operation were proved for both a promising heat-dissipation device and the energy architecture integrated with an additional energy system. PMID:22716909

  18. The evolution of helical cosmic magnetic fields as predicted by MHD closure theory

    Energy Technology Data Exchange (ETDEWEB)

    Saveliev, Andrey; Sigl, Guenter [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Jedamzik, Kartsen [Univ. Montpellier-2. (France). Laboratoire Univers et Particules de Montpellier

    2013-04-15

    We extend our recent derivation of the time evolution equations for the energy content of magnetic fields and turbulent motions for incompressible, homogeneous, and isotropic turbulence to include the case of non-vanishing helicity. These equations are subsequently numerically integrated in order to predict the present day primordial magnetic field strength and correlation length, depending on its initial helicity and magnetic energy density. We find that all prior analytic predictions for helical magnetic fields, such as the epoch when they become maximally helical and their subsequent growth of correlation length L {proportional_to} a{sup 1/3} and decrease of magnetic field strength B {proportional_to} a{sup -1/3} with scale factor a are well confirmed by the simulations. An initially fully helical primordial magnetic field is a factor 4 x 10{sup 4} stronger at the present epoch then its non-helical counterpart when generated during the electroweak epoch.

  19. Transfer of Chemically Modified Graphene with Retention of Functionality for Surface Engineering.

    Science.gov (United States)

    Whitener, Keith E; Lee, Woo-Kyung; Bassim, Nabil D; Stroud, Rhonda M; Robinson, Jeremy T; Sheehan, Paul E

    2016-02-10

    Single-layer graphene chemically reduced by the Birch process delaminates from a Si/SiOx substrate when exposed to an ethanol/water mixture, enabling transfer of chemically functionalized graphene to arbitrary substrates such as metals, dielectrics, and polymers. Unlike in previous reports, the graphene retains hydrogen, methyl, and aryl functional groups during the transfer process. This enables one to functionalize the receiving substrate with the properties of the chemically modified graphene (CMG). For instance, magnetic force microscopy shows that the previously reported magnetic properties of partially hydrogenated graphene remain after transfer. We also transfer hydrogenated graphene from its copper growth substrate to a Si/SiOx wafer and thermally dehydrogenate it to demonstrate a polymer- and etchant-free graphene transfer for potential use in transmission electron microscopy. Finally, we show that the Birch reduction facilitates delamination of CMG by weakening van der Waals forces between graphene and its substrate.

  20. Nanoscale control of stripe-ordered magnetic domain walls by vertical spin transfer torque in La0.67Sr0.33MnO3 film

    Science.gov (United States)

    Wang, Jing; Wu, Shizhe; Ma, Ji; Xie, Lishan; Wang, Chuanshou; Malik, Iftikhar Ahmed; Zhang, Yuelin; Xia, Ke; Nan, Ce-Wen; Zhang, Jinxing

    2018-02-01

    Stripe-ordered domains with perpendicular magnetic anisotropy have been intensively investigated due to their potential applications in high-density magnetic data-storage devices. However, the conventional control methods (e.g., epitaxial strain, local heating, magnetic field, and magnetoelectric effect) of the stripe-ordered domain walls either cannot meet the demands for miniaturization and low power consumption of spintronic devices or require high strength of the electric field due to the small value of the magnetoelectric effect at room temperature. Here, a domain-wall resistive effect of 0.1% was clarified in La0.67Sr0.33MnO3 thin films between the configurations of current in the plane and perpendicular to the plane of walls. Furthermore, a reversible nanoscale control of the domain-wall re-orientation by vertical spin transfer torque across the probe/film interface was achieved, where a probe voltage of 0.1 V was applied on a manganite-based capacitor. We also demonstrated that the stripe-ordered magnetic domain-wall re-orientation strongly depends on the AC frequency of the scanning probe voltage which was applied on the capacitor.

  1. Optimization of magnetoresistive sensor current for on-chip magnetic bead detection using the sensor self-field

    DEFF Research Database (Denmark)

    Henriksen, Anders Dahl; Rizzi, Giovanni; Østerberg, Frederik Westergaard

    2015-01-01

    We investigate the self-heating of magnetoresistive sensors used for measurements on magnetic beads in magnetic biosensors. The signal from magnetic beads magnetized by the field due to the sensor bias current is proportional to the bias current squared. Therefore, we aim to maximize the bias...... current while limiting the sensor self-heating. We systematically characterize and model the Joule heating of magnetoresistive sensors with different sensor geometries and stack compositions. The sensor heating is determined using the increase of the sensor resistance as function of the bias current......, thus the heat conductance is proportional to the sensor area and inversely proportional to the oxide thickness. This simple heat conductance determines the relationship between bias current and sensor temperature, and we show that View the MathML source25μm wide sensor on a View the MathML source1μm...

  2. Pair transfer processes probed at deep sub barrier energies

    International Nuclear Information System (INIS)

    Corradi, L.; Mason, P.; Fioretto, E.; Michelagnoli, C.; Stefanini, A.M.; Valiente-Dobon, J.J.; Szinler, S.; Jelavic-Malenica, D.; Soic, N.; Pollarolo, G.; Farnea, E.; Montagnoli, G.; Montanari, D.; Scarlassara, F.; Ur, C.A.; Gadea, A.; Haas, F.; Marginean, N.

    2011-01-01

    Multinucleon transfer cross sections in the system 40 Ca+ 96 Zr have been measured at bombarding energies ranging from the Coulomb barrier to ∼ 25% below. Target-like (lighter) recoils in inverse kinematics have been completely identified in A,Z and Q-value with the large solid angle magnetic spectrometer PRISMA. The experimental slopes of the neutron transfer probabilities at large internuclear separation are consistent with the values derived from the binding energies. A phenomenological interpretation of the transfer probabilities indicates the presence of enhanced values for the even number of neutron transfers. (authors)

  3. AC magnetic measurements of the ALS Booster Synchrotron Dipole Magnet engineering model

    International Nuclear Information System (INIS)

    Green, M.I.; Hoyer, E.; Keller, R.; Nelson, D.H.

    1988-09-01

    We made a minimal set of AC magnetic measurements of the engineering model of the ALS Booster Dipole Magnet as part of the process of qualifying its design for production. Magnetic induction integrals over paths approximating electron-beam trajectories were measured with long curved coils connected to an electronic integrator. Magnetic induction was measured with point coils and an integrator and independently with a Hall-effect Gaussmeter. These quantities, and magnet current, were displayed on a commercial digital storage oscilloscope as parametric functions of time. The displayed waveforms were stored, processed and redisplayed as representations of selected magnet parameters. A waveform representing the magnet's effective-length was created by dividing the integral waveform by the magnetic induction waveform. Waveforms of the transfer functions were produced by dividing both the integral waveform and the magnetic induction waveform by the current waveform. Pairs of matched coils, connected in series opposition, provided differential measurements of field uniformity. Quadrupole and sextupole coefficients were derived from the uniformity data. These magnet parameters were measured at 2 and 10 Hz frequencies. Together with measurements of the magnetic field at selected dc levels, the ac measurements demonstrated that the magnet design met specifications and qualified it for production. 7 refs., 7 figs., 3 tabs

  4. Preparation, characteristics, convection and applications of magnetic nanofluids: A review

    Science.gov (United States)

    Kumar, Aditya; Subudhi, Sudhakar

    2018-02-01

    Magnetic nanofluids (MNfs), the colloidal suspension of ferromagnetic nanomaterial, have been taken into research fascinatingly. After contemplating its distinctive interesting properties and unique eximious features it offers innumerous application not only in heat transfer field but also immensely prevalent in medical, biological, aerospace, electronics and solar sciences. This review paper epitomizes and perusing the research work done on heat transfer application of MNfs and encapsulate it for the future research support. Moreover, numerical and experimental, both the approaches has been included for the insightful analysis of phenomenon to apprehend augmentation in heat transfer by MNfs. This article first underlines the importance of appropriate methods of preparation of MNfs as well as its effects on the thermophysical properties of MNfs. Subsequently, the paper comprehended the descriptive analysis of augmentation of convection heat transfer and the effect of magnetic field on the behavior MNfs. Additionally, the effect of magnetic field intensity has been taken as a pertinent parameter and correlations have been developed for thermal conductivity, viscosity and heat transfer coefficient based on the reviewed data. The paper concluded with the tremendous applications of the MNfs and the futuristic plan to support the potential areas for future research.

  5. Batch extracting process using magnetic particle held solvents

    Science.gov (United States)

    Nunez, L.; Vandergrift, G.F.

    1995-11-21

    A process is described for selectively removing metal values which may include catalytic values from a mixture containing same, wherein a magnetic particle is contacted with a liquid solvent which selectively dissolves the metal values to absorb the liquid solvent onto the magnetic particle. Thereafter the solvent-containing magnetic particles are contacted with a mixture containing the heavy metal values to transfer metal values into the solvent carried by the magnetic particles, and then magnetically separating the magnetic particles. Ion exchange resins may be used for selective solvents. 5 figs.

  6. Adaptive bayesian analysis for binomial proportions

    CSIR Research Space (South Africa)

    Das, Sonali

    2008-10-01

    Full Text Available of testing the proportion of some trait. For example, say, we are interested to infer about the effectiveness of a certain intervention teaching strategy, by comparing proportion of ‘proficient’ teachers, before and after an intervention. The number...

  7. Beam transfer line for food irradiation microtron at CAT

    International Nuclear Information System (INIS)

    Kant, Pradeep; Singh, Gurnam

    2003-01-01

    A 10 MeV microtron is being developed at CAT for irradiation of food products. A beam transfer line comprising a 90 deg bending magnet, a quadrupole doublet and a rectangular scanning magnet has been designed to irradiate food products from the upper side. The bending magnet has an edge angle of 22.5 deg. The length of the beam transfer line has been minimized to keep the whole unit as compact as possible. The beam optics has been optimized keeping in view the requirement of a small beam pipe aperture (25mm radius) and a large range of circular as well as elliptical beam sizes on the food product. The speed of the conveyor belt has been assumed to be very small. The results of the beam optics chosen and the variation of the linear charge density on a food product during the scanning are presented in this paper. The effects of path length variation within the scanning magnet and beam size variation during a scanning are also discussed

  8. Thermal conductance of heat transfer interfaces for conductively cooled superconducting magnets

    International Nuclear Information System (INIS)

    Cooper, T.L.; Walters, J.D.; Fikse, T.H.

    1996-01-01

    Minimizing thermal resistances across interfaces is critical for efficient thermal performance of conductively cooled superconducting magnet systems. Thermal conductance measurements have been made for a flexible thermal coupling, designed to accommodate magnet-to-cryocooler and cryocooler-to-shield relative motion, and an interface incorporating Multilam designed as a sliding thermal connector for cryocoolers. Temperature changes were measured across each interface as a function of heat input. Thermal conductances have been calculated for each interface, and the impact of each interface on conductively cooled magnet systems will be discussed

  9. Icon arrays help younger children's proportional reasoning.

    Science.gov (United States)

    Ruggeri, Azzurra; Vagharchakian, Laurianne; Xu, Fei

    2018-06-01

    We investigated the effects of two context variables, presentation format (icon arrays or numerical frequencies) and time limitation (limited or unlimited time), on the proportional reasoning abilities of children aged 7 and 10 years, as well as adults. Participants had to select, between two sets of tokens, the one that offered the highest likelihood of drawing a gold token, that is, the set of elements with the greater proportion of gold tokens. Results show that participants performed better in the unlimited time condition. Moreover, besides a general developmental improvement in accuracy, our results show that younger children performed better when proportions were presented as icon arrays, whereas older children and adults were similarly accurate in the two presentation format conditions. Statement of contribution What is already known on this subject? There is a developmental improvement in proportional reasoning accuracy. Icon arrays facilitate reasoning in adults with low numeracy. What does this study add? Participants were more accurate when they were given more time to make the proportional judgement. Younger children's proportional reasoning was more accurate when they were presented with icon arrays. Proportional reasoning abilities correlate with working memory, approximate number system, and subitizing skills. © 2018 The British Psychological Society.

  10. Use and misuse of material transfer agreements: lessons in proportionality from research, repositories, and litigation.

    Directory of Open Access Journals (Sweden)

    Tania Bubela

    2015-02-01

    Full Text Available Material transfer agreements exist to facilitate the exchange of materials and associated data between researchers as well as to protect the interests of the researchers and their institutions. But this dual mandate can be a source of frustration for researchers, creating administrative burdens and slowing down collaborations. We argue here that in most cases in pre-competitive research, a simple agreement would suffice; the more complex agreements and mechanisms for their negotiation should be reserved for cases where the risks posed to the institution and the potential commercial value of the research reagents is high.

  11. Apparatus and method for continuous separation of magnetic particles from non-magnetic fluids

    Science.gov (United States)

    Oder, Robin R.; Jamison, Russell E.

    2010-02-09

    A magnetic separator vessel (1) for separating magnetic particles from non-magnetic fluid includes a separation chamber having an interior and exterior wall, a top and bottom portion; a magnet (3) having first and second poles (2) positioned adjacent to the exterior wall, wherein the first pole is substantially diametrically opposed to the second pole; a inlet port (5) is directed into the top portion of the separation chamber, wherein the inlet port (5) is positioned adjacent to one of the first and second poles (2), wherein the inlet port (5) is adapted to transfer a mixture into the separation chamber; an underflow port (6) in communication with the bottom portion, wherein the underflow port (6) is adapted to receive the magnetic particles; and an overflow port (9) in communication with the separation chamber, wherein the overflow port (9) is adapted to receive the non-magnetic fluid.

  12. Heat Flux of a Transferred Arc Driven by a Transverse Magnetic Field

    Directory of Open Access Journals (Sweden)

    Naomi Matsumoto

    2009-01-01

    Full Text Available Theoretical consideration of a magnetically driven arc was performed to elucidate the variation of heat flux with an imposed DC magnetic field. Experiments were conducted to confirm the validity of the theoretical model. The heat flux decreased concomitantly with increased imposed magnetic flux density. Theoretical predictions agreed with experimental results.

  13. Superconducting magnetic energy storage

    International Nuclear Information System (INIS)

    Rogers, J.D.; Boenig, H.J.

    1978-01-01

    Superconducting inductors provide a compact and efficient means of storing electrical energy without an intermediate conversion process. Energy storage inductors are under development for diurnal load leveling and transmission line stabilization in electric utility systems and for driving magnetic confinement and plasma heating coils in fusion energy systems. Fluctuating electric power demands force the electric utility industry to have more installed generating capacity than the average load requires. Energy storage can increase the utilization of base-load fossil and nuclear power plants for electric utilities. Superconducting magnetic energy storage (SMES) systems, which will store and deliver electrical energy for load leveling, peak shaving, and the stabilization of electric utility networks are being developed. In the fusion area, inductive energy transfer and storage is also being developed by LASL. Both 1-ms fast-discharge theta-pinch and 1-to-2-s slow tokamak energy transfer systems have been demonstrated. The major components and the method of operation of an SMES unit are described, and potential applications of different size SMES systems in electric power grids are presented. Results are given for a 1-GWh reference design load-leveling unit, for a 30-MJ coil proposed stabilization unit, and for tests with a small-scale, 100-kJ magnetic energy storage system. The results of the fusion energy storage and transfer tests are also presented. The common technology base for the systems is discussed

  14. Cognitive and Metacognitive Aspects of Proportional Reasoning

    Science.gov (United States)

    Modestou, Modestina; Gagatsis, Athanasios

    2010-01-01

    In this study we attempt to propose a new model of proportional reasoning based both on bibliographical and research data. This is impelled with the help of three written tests involving analogical, proportional, and non-proportional situations that were administered to pupils from grade 7 to 9. The results suggest the existence of a…

  15. Temperature dependence of microwave oscillations in magnetic tunnel junctions with a perpendicularly magnetized free layer

    International Nuclear Information System (INIS)

    Guo, Peng; Feng, Jiafeng; Wei, Hongxiang; Han, Xiufeng; Fang, Bin; Zhang, Baoshun; Zeng, Zhongming

    2015-01-01

    We experimentally study the temperature dependence of the spin-transfer-torque-induced microwave oscillations in MgO-based magnetic tunnel junction nanopillars with a perpendicularly magnetized free layer. We demonstrate that the oscillation frequency increases rapidly with decreasing temperature, which is mainly ascribed to the temperature dependence of both the saturation magnetization and the perpendicular magnetic anisotropy. We also find that a strong temperature dependence of the output power while a nonmonotonic temperature dependence of spectral linewidth are maintained for a constant dc bias in measured temperature range. Possible mechanisms leading to the different dependences of oscillation frequency, output power, and linewidth are discussed

  16. Gravitational collapse of a magnetized fermion gas with finite temperature

    Energy Technology Data Exchange (ETDEWEB)

    Delgado Gaspar, I. [Instituto de Geofisica y Astronomia (IGA), La Habana (Cuba); Perez Martinez, A. [Instituto de Cibernetica, Matematica y Fisica (ICIMAF), La Habana (Cuba); Sussman, Roberto A. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico (ICN-UNAM), Mexico (Mexico); Ulacia Rey, A. [Instituto de Cibernetica, Matematica y Fisica (ICIMAF), La Habana (Cuba); Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico (ICN-UNAM), Mexico (Mexico)

    2013-07-15

    We examine the dynamics of a self-gravitating magnetized fermion gas at finite temperature near the collapsing singularity of a Bianchi-I spacetime. Considering a general set of appropriate and physically motivated initial conditions, we transform Einstein-Maxwell field equations into a complete and self-consistent dynamical system amenable for numerical work. The resulting numerical solutions reveal the gas collapsing into both, isotropic (''point-like'') and anisotropic (''cigar-like''), singularities, depending on the initial intensity of the magnetic field. We provide a thorough study of the near collapse behavior and interplay of all relevant state and kinematic variables: temperature, expansion scalar, shear scalar, magnetic field, magnetization, and energy density. A significant qualitative difference in the behavior of the gas emerges in the temperature range T/m{sub f} {proportional_to} 10{sup -6} and T/m{sub f} {proportional_to} 10{sup -3}. (orig.)

  17. Enhancement of turbulent flow heat transfer in a tube with modified twisted tapes

    Energy Technology Data Exchange (ETDEWEB)

    Lei, Y.G.; Zhao, C.H.; Song, C.F. [College of Environmental Science and Engineering, Taiyuan University of Technology, Taiyuan (China)

    2012-12-15

    Numerical simulations were performed to study the fluid flow and heat transfer in a tube with staggered twisted tapes with central holes. In the range of Reynolds numbers between 6000 and 28 000, the modified twisted tapes increased the Nusselt number by 76.2 {proportional_to} 149.7 % and the friction factor by 380.2 {proportional_to} 443.8 % compared to the smooth tube. Compared to the typical twisted tapes, the modified twisted tapes produced an acceleration flow through the triangle regions leading to the enhancement of heat transfer, and the holes in the modified tapes reduced the severe pressure loss. It was found that the modified twisted tapes decreased the friction factor by 8.0 {proportional_to} 16.1 % and enhanced the heat transfer by 34.1 {proportional_to} 46.8 % in comparison with the typical tapes. These results indicated that the performance ratio values of the tube with modified twisted tapes were higher than 1.0 in the range of Reynolds numbers studied. The computed performance ratios of the tube with modified twisted tapes were much higher than those of the tube with typical twisted tapes. This means that the integrated performance of the tube with staggered twisted tapes with central holes is superior to that of the tube with typical twisted tapes. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Symmetric and Asymmetric Magnetic Tunnel Junctions with Embedded Nanoparticles: Effects of Size Distribution and Temperature on Tunneling Magnetoresistance and Spin Transfer Torque.

    Science.gov (United States)

    Useinov, Arthur; Lin, Hsiu-Hau; Lai, Chih-Huang

    2017-08-21

    The problem of the ballistic electron tunneling is considered in magnetic tunnel junction with embedded non-magnetic nanoparticles (NP-MTJ), which creates additional conducting middle layer. The strong temperature impact was found in the system with averaged NP diameter d av  tunneling magnetoresistance (TMR) voltage behaviors. The low temperature approach also predicts step-like TMR and quantized in-plane spin transfer torque (STT) effects. The robust asymmetric STT respond is found due to voltage sign inversion in NP-MTJs with barrier asymmetry. Furthermore, it is shown how size distribution of NPs as well as quantization rules modify the spin-current filtering properties of the nanoparticles in ballistic regime. Different quantization rules for the transverse component of the wave vector are considered to overpass the dimensional threshold (d av  ≈ 1.8 nm) between quantum well and bulk-assisted states of the middle layer.

  19. Relating arithmetical techniques of proportion to geometry

    DEFF Research Database (Denmark)

    Wijayanti, Dyana

    2015-01-01

    The purpose of this study is to investigate how textbooks introduce and treat the theme of proportion in geometry (similarity) and arithmetic (ratio and proportion), and how these themes are linked to each other in the books. To pursue this aim, we use the anthropological theory of the didactic....... Considering 6 common Indonesian textbooks in use, we describe how proportion is explained and appears in examples and exercises, using an explicit reference model of the mathematical organizations of both themes. We also identify how the proportion themes of the geometry and arithmetic domains are linked. Our...

  20. Maternal transfer of contaminants in birds: Mercury and selenium concentrations in parents and their eggs

    International Nuclear Information System (INIS)

    Ackerman, Joshua T.; Eagles-Smith, Collin A.; Herzog, Mark P.; Hartman, C. Alex

    2016-01-01

    We conducted a detailed assessment of the maternal transfer of mercury and selenium to eggs in three bird species (n = 107 parents and n = 339 eggs), and developed predictive equations linking contaminant concentrations in eggs to those in six tissues of the mother (blood, muscle, liver, kidney, breast feathers, and head feathers). Mercury concentrations in eggs were positively correlated with mercury concentrations in each of the mother's internal tissues (R"2 ≥ 0.95), but generally not with feathers. For each species, the proportion of mercury transferred to eggs decreased as mercury concentrations in the mother increased. At the same maternal mercury concentration, the proportion of mercury transferred to eggs differed among species, such that Forster's tern (Sterna forsteri) and black-necked stilt (Himantopus mexicanus) females transferred more methylmercury to their eggs than American avocet (Recurvirostra americana) females. Selenium concentrations in eggs also were correlated with selenium concentrations in the mother's liver (R"2 = 0.87). Furthermore, mercury and selenium concentrations in tern eggs were positively correlated with those in the father (R"2 = 0.84). Incubating male terns had 21% higher mercury concentrations in blood compared to incubating females at the same egg mercury concentration. We provide equations to predict contaminant concentrations in eggs from each of the commonly sampled bird tissues. - Highlights: • We developed predictive equations linking contaminant concentrations in eggs to those in the mother. • Mercury concentrations in eggs were positively correlated with those in the mother. • The proportion of mercury transferred to eggs decreased as mercury in the mother increased. • The proportion of mercury transferred to eggs differed among species. • Selenium concentrations in eggs also were correlated with those in the mother's liver. - We examined the maternal transfer of mercury and selenium to eggs in

  1. RADIALLY MAGNETIZED PROTOPLANETARY DISK: VERTICAL PROFILE

    International Nuclear Information System (INIS)

    Russo, Matthew; Thompson, Christopher

    2015-01-01

    This paper studies the response of a thin accretion disk to an external radial magnetic field. Our focus is on protoplanetary disks (PPDs), which are exposed during their later evolution to an intense, magnetized wind from the central star. A radial magnetic field is mixed into a thin surface layer, wound up by the disk shear, and pushed downward by a combination of turbulent mixing and ambipolar and ohmic drift. The toroidal field reaches much greater strengths than the seed vertical field that is usually invoked in PPD models, even becoming superthermal. Linear stability analysis indicates that the disk experiences the magnetorotational instability (MRI) at a higher magnetization than a vertically magnetized disk when both the effects of ambipolar and Hall drift are taken into account. Steady vertical profiles of density and magnetic field are obtained at several radii between 0.06 and 1 AU in response to a wind magnetic field B r ∼ (10 −4 –10 −2 )(r/ AU) −2 G. Careful attention is given to the radial and vertical ionization structure resulting from irradiation by stellar X-rays. The disk is more strongly magnetized closer to the star, where it can support a higher rate of mass transfer. As a result, the inner ∼1 AU of a PPD is found to evolve toward lower surface density. Mass transfer rates around 10 −8 M ⊙ yr −1 are obtained under conservative assumptions about the MRI-generated stress. The evolution of the disk and the implications for planet migration are investigated in the accompanying paper

  2. Split-Field Magnet facility upgraded

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    The Split Field Magnet (SFM) was the largest spectrometer for particles from beam-beam collisions in the ISR. It could determine particle momenta in a large solid angle, but was designed mainly for the analysis of forward travelling particles.As the magnet was working on the ISR circulating beams, its magnetic field had to be such as to restore the correct proton orbit.The SFM, therefore, produced zero field at the crossing point and fields of opposite signs upstream and downstream of it and was completed by 2 large and 2 small compensator magnets. The gradient effects were corrected by magnetic channels equipped with movable flaps. The useful magnetic field volume was 28 m3, the induction in the median plane 1.14 T, the gap heigth 1.1 m, the length 10.5 m, the weight about 1000 ton. Concerning the detectors, the SFM was the first massive application of multiwire proportional chambers (about 70000 wires) which filled the main and the large compensator magnets. In 1976 an improved programme was started with tw...

  3. Chaotic approach to evaluation of disturbed magnetic surfaces

    International Nuclear Information System (INIS)

    Kogoshi, Sumio; Mishimagi, Sigehiro; Yoshii, Keiichi; Maeda, Joji

    1998-01-01

    A circle mapping can approximately reproduce the cross section of magnetic surfaces and the value of the periodic driving force (K) at a magnetic island varies with the width of the magnetic island, which suggests the value of K is one of measures for the degradation of magnetic surfaces. The profile of a rotational transform has flat regions at the magnetic islands. The width of the flat region is proportional to the width of the magnetic island. Therefore it may be another measure of the degradation of magnetic surfaces. This method requires less data for the estimation than the usual method of calculating the width of magnetic islands. For collapsed magnetic surfaces that are produced by overlapping of two magnetic islands, the fractal dimension can effectively estimate the degradation of them. The fractal dimensions of cross sections of regular magnetic surfaces and clear magnetic islands are nearly 1, while that of a collapsed magnetic surface is about 1.2 in the present study. (author)

  4. Magnetic field influence on the selfquenching streamer discharge

    International Nuclear Information System (INIS)

    Alekseev, G.D.; Korytov, A.V.

    1987-01-01

    The influence of the magnetic field on the selfquenching streamer discharge characteristics is investigated. In the field about 10 kGs streamer charge is decreased several per cent (change of charge is due to amplitude decreasing of signal). In the transition region from limited-proportional to streamer mode magnetic field results in increasing of probability of avalanche developing into a streamer

  5. Proportional Reasoning and the Visually Impaired

    Science.gov (United States)

    Hilton, Geoff; Hilton, Annette; Dole, Shelley L.; Goos, Merrilyn; O'Brien, Mia

    2012-01-01

    Proportional reasoning is an important aspect of formal thinking that is acquired during the developmental years that approximate the middle years of schooling. Students who fail to acquire sound proportional reasoning often experience difficulties in subjects that require quantitative thinking, such as science, technology, engineering, and…

  6. Interaction mechanisms and biological effects of static magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Tenforde, T.S.

    1994-06-01

    Mechanisms through which static magnetic fields interact with living systems are described and illustrated by selected experimental observations. These mechanisms include electrodynamic interactions with moving, ionic charges (blood flow and nerve impulse conduction), magnetomechanical interactions (orientation and translation of molecules structures and magnetic particles), and interactions with electronic spin states in charge transfer reactions (photo-induced electron transfer in photosynthesis). A general summary is also presented of the biological effects of static magnetic fields. There is convincing experimental evidence for magnetoreception mechanisms in several classes of lower organisms, including bacteria and marine organisms. However, in more highly evolved species of animals, there is no evidence that the interactions of static magnetic fields with flux densities up to 2 Tesla (1 Tesla [T] = 10{sup 4} Gauss) produce either behavioral or physiolocical alterations. These results, based on controlled studies with laboratory animals, are consistent with the outcome of recent epidemiological surveys on human populations exposed occupationally to static magnetic fields.

  7. Workshop on accelerator magnet superconductors. Proceedings

    International Nuclear Information System (INIS)

    2004-01-01

    The workshop on accelerator magnet superconductors has gathered 102 registered participants from research laboratories, universities and industry. 8 European companies, active in superconducting materials and cables were present. This workshop has been organized to deal with the status of the world research and development on superconducting materials and cables for high field magnets (B > 10 T). The workshop has also reviewed the status of high temperature superconductors and transmission line cables for potential use in low field superconducting magnets for injectors and beam transfer lines, as well as cables for pulsed magnets that might be used in future hadron colliders or injectors

  8. Workshop on accelerator magnet superconductors. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    The workshop on accelerator magnet superconductors has gathered 102 registered participants from research laboratories, universities and industry. 8 European companies, active in superconducting materials and cables were present. This workshop has been organized to deal with the status of the world research and development on superconducting materials and cables for high field magnets (B > 10 T). The workshop has also reviewed the status of high temperature superconductors and transmission line cables for potential use in low field superconducting magnets for injectors and beam transfer lines, as well as cables for pulsed magnets that might be used in future hadron colliders or injectors.

  9. Transient heat transfer in liquid helium

    International Nuclear Information System (INIS)

    Shiotsu, Masahiro

    1991-01-01

    Detailed knowledge on the steady-state and transient heat transfer from solid surfaces in He I and He II is important as a database for the analysis of the influence of local thermal disturbances on the stability of He I or He II cooled large superconducting magnets. In this paper, an overview of the transient heat transfer characteristics on solid surfaces in He I and He II caused by various large stepwise heat inputs, such as the quasi-steady nucleate boiling with a certain lifetime in He I and the quasi-steady Kapitza conductance heat flux with a certain lifetime in He II, are presented in comparison with their steady-state heat transfer characteristics. (author)

  10. A fundamental study of a regenerator for an Ericsson magnetic refrigerator

    International Nuclear Information System (INIS)

    Matsumoto, K.; Ito, T.; Numazawa, T.; Hashimoto, T.; Kuriyama, T.; Nakagome, H.

    1986-01-01

    The authors studied an Ericsson magnetic refrigerator above 20 K. The magnetic working material passes through the regenerator during internal heat transfer processes. In the temperature range above 20 K, a solid is indispensable for a regenerator in need of the large volumetric heat capacity. Therefore lead is used for the testing regenerator. As thermal conduction of gaseous helium is expected to be useful for the heat transfer between the regenerator and the working material, the authors have made the gap between them small in order to achieve good heat transfer. They investigated the heat transfer process between working material and regenerator experimentally in the temperature from 25 K to 55 K

  11. Magnetic field enhancement of organic photovoltaic cells performance.

    Science.gov (United States)

    Oviedo-Casado, S; Urbina, A; Prior, J

    2017-06-27

    Charge separation is a critical process for achieving high efficiencies in organic photovoltaic cells. The initial tightly bound excitonic electron-hole pair has to dissociate fast enough in order to avoid photocurrent generation and thus power conversion efficiency loss via geminate recombination. Such process takes place assisted by transitional states that lie between the initial exciton and the free charge state. Due to spin conservation rules these intermediate charge transfer states typically have singlet character. Here we propose a donor-acceptor model for a generic organic photovoltaic cell in which the process of charge separation is modulated by a magnetic field which tunes the energy levels. The impact of a magnetic field is to intensify the generation of charge transfer states with triplet character via inter-system crossing. As the ground state of the system has singlet character, triplet states are recombination-protected, thus leading to a higher probability of successful charge separation. Using the open quantum systems formalism we demonstrate that the population of triplet charge transfer states grows in the presence of a magnetic field, and discuss the impact on carrier population and hence photocurrent, highlighting its potential as a tool for research on charge transfer kinetics in this complex systems.

  12. Proportional gas scintillation detectors and their applications

    International Nuclear Information System (INIS)

    Petr, I.

    1978-01-01

    The principle is described of a gas proportional scintillation detector and its function. Dependence of Si(Li) and xenon proportional detectors energy resolution on the input window size is given. A typical design is shown of a xenon detector used for X-ray spetrometry at an energy of 277 eV to 5.898 keV and at a gas pressure of 98 to 270 kPa. Gas proportional scintillation detectors show considerable better energy resolution than common proportional counters and even better resolution than semiconductor Si(Li) detectors for low X radiation energies. For detection areas smaller than 25 mm 2 Si(Li) detectors show better resolution, especially for higher X radiation energies. For window areas 25 to 190 mm 2 both types of detectors are equal, for a window area exceeding 190 mm 2 the proportional scintillation detector has higher energy resolution. (B.S.)

  13. What Caused the Lead burn-out in Spectrometer Magnet 2B

    International Nuclear Information System (INIS)

    Green, Michael A.

    2010-01-01

    The spectrometer solenoids are supposed to be the first magnets installed in the MICE Cooling Channel. The results of the test of Spectrometer Magnet 2B are reported in a previous MICE Note. Magnet 2B was tested with all five coils connected in series. The magnet failed because a lead to coil M2 failed before it could be trained to its full design current of 275 A. First, this report describes the condition of the magnet when the lead failure occurred. The lead that failed was between the cold mass feed-through and the heavy lead that connected to coil M2 and the quench protection diodes. It is believed that the lead failed because the minimum propagation zone (MPZ) length was too short. The quench was probably triggered by lead motion in the field external to the magnet center coil. The effect of heat transfer on quench propagation and MPZ length is discussed. The MPZ length is compared for a number of cases that apply to the spectrometer solenoid 2B as built and as it has been repaired. The required heat transfer coefficient for cryogenic stability and the quench propagation velocity along the leads are compared for various parts of the Magnet leads inside the cold mass cryostat. The effect of the insulation on leads on heat transfer is and stability is discussed.

  14. Effect of polarized radiative transfer on the Hanle magnetic field determination in prominences: Analysis of hydrogen H alpha line observations at Pic-du-Midi

    Science.gov (United States)

    Bommier, V.; Deglinnocenti, E. L.; Leroy, J. L.; Sahal-Brechot, S.

    1985-01-01

    The linear polarization of the Hydrogen H alpha line of prominences has been computed, taking into account the effect of a magnetic field (Hanle effect), of the radiative transfer in the prominence, and of the depolarization due to collisions with the surrounding electrons and protons. The corresponding formalisms are developed in a forthcoming series of papers. In this paper, the main features of the computation method are summarized. The results of computation have been used for interpretation in terms of magnetic field vector measurements from H alpha polarimetric observations in prominences performed at Pic-du-Midi coronagraph-polarimeter. Simultaneous observations in one optically thin line (He I D(3)) and one optically thick line (H alpha) give an opportunity for solving the ambiguity on the field vector determination.

  15. Emergent magnetism at transition-metal-nanocarbon interfaces.

    Science.gov (United States)

    Al Ma'Mari, Fatma; Rogers, Matthew; Alghamdi, Shoug; Moorsom, Timothy; Lee, Stephen; Prokscha, Thomas; Luetkens, Hubertus; Valvidares, Manuel; Teobaldi, Gilberto; Flokstra, Machiel; Stewart, Rhea; Gargiani, Pierluigi; Ali, Mannan; Burnell, Gavin; Hickey, B J; Cespedes, Oscar

    2017-05-30

    Charge transfer at metallo-molecular interfaces may be used to design multifunctional hybrids with an emergent magnetization that may offer an eco-friendly and tunable alternative to conventional magnets and devices. Here, we investigate the origin of the magnetism arising at these interfaces by using different techniques to probe 3d and 5d metal films such as Sc, Mn, Cu, and Pt in contact with fullerenes and rf-sputtered carbon layers. These systems exhibit small anisotropy and coercivity together with a high Curie point. Low-energy muon spin spectroscopy in Cu and Sc-C 60 multilayers show a quick spin depolarization and oscillations attributed to nonuniform local magnetic fields close to the metallo-carbon interface. The hybridization state of the carbon layers plays a crucial role, and we observe an increased magnetization as sp 3 orbitals are annealed into sp 2 -π graphitic states in sputtered carbon/copper multilayers. X-ray magnetic circular dichroism (XMCD) measurements at the carbon K edge of C 60 layers in contact with Sc films show spin polarization in the lowest unoccupied molecular orbital (LUMO) and higher π*-molecular levels, whereas the dichroism in the σ*-resonances is small or nonexistent. These results support the idea of an interaction mediated via charge transfer from the metal and dz -π hybridization. Thin-film carbon-based magnets may allow for the manipulation of spin ordering at metallic surfaces using electrooptical signals, with potential applications in computing, sensors, and other multifunctional magnetic devices.

  16. Lattice Boltzmann simulation for temperature-sensitive magnetic fluids in a porous square cavity

    International Nuclear Information System (INIS)

    Jin Licong; Zhang Xinrong; Niu Xiaodong

    2012-01-01

    A lattice Boltzmann method is developed to simulate temperature-sensitive magnetic fluids in a porous cavity. In the simulation, the magnetic force, efficient gravity, viscous loss term and geometric loss term in porous medium are imported to the momentum equation. To test the reliability of the method, a validation with water in porous cavity is carried out. Good agreements with the previous results verify that the present lattice Boltzmann method is promising for simulation of magnetic fluids in porous medium. In this study, we investigate the change of magnetization with external magnetic field, and we present numerical results for the streamlines, isotherms, and magnetization at vertical or horizontal mid-profiles for different values of Ram. In addition, Nusselt numbers changing with magnetic Rayleigh numbers are also investigated. - Highlights: → Developed a lattice Boltzmann method for magnetic nano-fluids in porous cavity. → Clarified flow and heat transfer for different values of (magnetic) Rayleigh numbers. → Heat transfer enhancement for magnetic fluid in porous cavity.

  17. Bayesian inference on proportional elections.

    Directory of Open Access Journals (Sweden)

    Gabriel Hideki Vatanabe Brunello

    Full Text Available Polls for majoritarian voting systems usually show estimates of the percentage of votes for each candidate. However, proportional vote systems do not necessarily guarantee the candidate with the most percentage of votes will be elected. Thus, traditional methods used in majoritarian elections cannot be applied on proportional elections. In this context, the purpose of this paper was to perform a Bayesian inference on proportional elections considering the Brazilian system of seats distribution. More specifically, a methodology to answer the probability that a given party will have representation on the chamber of deputies was developed. Inferences were made on a Bayesian scenario using the Monte Carlo simulation technique, and the developed methodology was applied on data from the Brazilian elections for Members of the Legislative Assembly and Federal Chamber of Deputies in 2010. A performance rate was also presented to evaluate the efficiency of the methodology. Calculations and simulations were carried out using the free R statistical software.

  18. PROPORTIONS AND HUMAN SCALE IN DAMASCENE COURTYARD HOUSES

    Directory of Open Access Journals (Sweden)

    M. Salim Ferwati

    2008-03-01

    Full Text Available Interior designers, architects, landscape architects, and even urban designers, agree that environment, as a form of non-verbal communication means, has a symbolic dimension to it. As for its aesthetic dimension, it seems that beauty is related to a certain proportion, partially and as a whole. Suitable proportion leaves a good impression upon the beholders, especially when it matches human proportion. That in fact was the underlining belief of LeCorbusier, according to which he developed his Modular concept. The study searches for a modular, or proportion, system that governs the design of Damascene traditional house. By geometrical and mathematical examinations of 28 traditional houses, it was found that a certain proportional relationship existed; however, these proportional relationships were not fixed ones. The study relied on analyzing the Iwan elevation as well as the inner courtyard proportion in relation to the building area. Charts, diagrams and tables were produced to summarize the results.

  19. Momentum transfer resolved memory in a magnetic system with perpendicular anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Seu, Keoki; Roy, Sujoy; Su, Run; Parks, Daniel; Shipton, Erik; Fullerton, Eric; Kevan, Stephen

    2011-01-28

    We have used resonant, coherent soft x-ray scattering to measure wave vector re- solved magnetic domain memory in Co/Pd multilayers. The technique uses angular cross correlation functions and can be applied to any system with circular annuli of constant values of scattering wave vector q. In our Co/Pd film, the memory exhibits a maximum at q = 0.0384 nm-1 near initial reversal that decreases in magnitude as the magnetization is further reversed. The peak is attributed to bubble domains that nucleate reproducibly near initial reversal and which grow into a labyrinth domain structure that is not reproduced from one magnetization cycle to the next.

  20. Study of heat transfer and flow of nanofluid in permeable channel in the presence of magnetic field

    Directory of Open Access Journals (Sweden)

    M. Fakour

    2015-03-01

    Full Text Available In this paper, laminar fluid flow and heat transfer in channel with permeable walls in the presence of a transverse magnetic field is investigated. Least square method (LSM for computing approximate solutions of nonlinear differential equations governing the problem. We have tried to show reliability and performance of the present method compared with the numerical method (Runge-Kutta fourth-rate to solve this problem. The influence of the four dimensionless numbers: the Hartmann number, Reynolds number, Prandtl number and Eckert number on non-dimensional velocity and temperature profiles are considered. The results show analytical present method is very close to numerically method. In general, increasing the Reynolds and Hartman number is reduces the nanofluid flow velocity in the channel and the maximum amount of temperature increase and increasing the Prandtl and Eckert number will increase the maximum amount of theta.

  1. Optimization of transfer of laser-cooled atom cloud to a quadrupole ...

    Indian Academy of Sciences (India)

    2014-02-08

    Feb 8, 2014 ... Laser Physics Applications Section, Raja Ramanna Centre for Advanced Technology,. Indore 452 013 ... Laser cooling; optical molasses; double-MOT; magnetic trapping; phase-space density. PACS Nos 52.55. ... this method, the transfer of laser-cooled atom cloud to magnetic trap is an important step,.

  2. Review of magnetic refrigeration system as alternative to conventional refrigeration system

    Science.gov (United States)

    Mezaal, N. A.; Osintsev, K. V.; Zhirgalova, T. B.

    2017-10-01

    The refrigeration system is one of the most important systems in industry. Developers are constantly seeking for how to avoid the damage to the environment. Magnetic refrigeration is an emerging, environment-friendly technology based on a magnetic solid that acts as a refrigerant by magneto-caloric effect (MCE). In the case of ferromagnetic materials, MCE warms as the magnetic moments of the atom are aligned by the application of a magnetic field. There are two types of magnetic phase changes that may occur at the Curie point: first order magnetic transition (FOMT) and second order magnetic transition (SOMT). The reference cycle for magnetic refrigeration is AMR (Active Magnetic Regenerative cycle), where the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. Regeneration can be accomplished by blowing a heat transfer fluid in a reciprocating fashion through the regenerator made of magnetocaloric material that is alternately magnetized and demagnetized. Many magnetic refrigeration prototypes with different designs and software models have been built in different parts of the world. In this paper, the authors try to shed light on the magnetic refrigeration and show its effectiveness compared with conventional refrigeration methods.

  3. Voltage induced magnetostrictive switching of nanomagnets: Strain assisted strain transfer torque random access memory

    International Nuclear Information System (INIS)

    Khan, Asif; Nikonov, Dmitri E.; Manipatruni, Sasikanth; Ghani, Tahir; Young, Ian A.

    2014-01-01

    A spintronic device, called the “strain assisted spin transfer torque (STT) random access memory (RAM),” is proposed by combining the magnetostriction effect and the spin transfer torque effect which can result in a dramatic improvement in the energy dissipation relative to a conventional STT-RAM. Magnetization switching in the device which is a piezoelectric-ferromagnetic heterostructure via the combined magnetostriction and STT effect is simulated by solving the Landau-Lifshitz-Gilbert equation incorporating the influence of thermal noise. The simulations show that, in such a device, each of these two mechanisms (magnetostriction and spin transfer torque) provides in a 90° rotation of the magnetization leading a deterministic 180° switching with a critical current significantly smaller than that required for spin torque alone. Such a scheme is an attractive option for writing magnetic RAM cells.

  4. Voltage induced magnetostrictive switching of nanomagnets: Strain assisted strain transfer torque random access memory

    Science.gov (United States)

    Khan, Asif; Nikonov, Dmitri E.; Manipatruni, Sasikanth; Ghani, Tahir; Young, Ian A.

    2014-06-01

    A spintronic device, called the "strain assisted spin transfer torque (STT) random access memory (RAM)," is proposed by combining the magnetostriction effect and the spin transfer torque effect which can result in a dramatic improvement in the energy dissipation relative to a conventional STT-RAM. Magnetization switching in the device which is a piezoelectric-ferromagnetic heterostructure via the combined magnetostriction and STT effect is simulated by solving the Landau-Lifshitz-Gilbert equation incorporating the influence of thermal noise. The simulations show that, in such a device, each of these two mechanisms (magnetostriction and spin transfer torque) provides in a 90° rotation of the magnetization leading a deterministic 180° switching with a critical current significantly smaller than that required for spin torque alone. Such a scheme is an attractive option for writing magnetic RAM cells.

  5. Biological interactions and human health effects of static magnetic fields

    International Nuclear Information System (INIS)

    Tenforde, T.S.

    1994-09-01

    Mechanisms through which static magnetic fields interact with living systems will be described and illustrated by selected experimental observations. These mechanisms include electrodynamic interactions with moving ionic charges (blood flow and nerve impulse conduction), magnetomechanical interactions (orientation and translation of molecular structures and magnetic particles), and interactions with electronic spin states in charge transfer reactions (photo-induced electron transfer in photosynthesis). A general summary will also be presented of the biological effects of static magnetic fields studied in the laboratory and in natural settings. One aspect of magnetic field effects that merits special concern is their influence on implanted medical electronic devices such as cardiac pacemakers. Several extensive studies have demonstrated closure of the reed switch in pacemakers exposed to relatively weak static magnetic fields, thereby causing them to revert to an asynchronous mode of operation that is potentially hazardous. Recommendations for human exposure limits are provided

  6. Current-induced magnetization dynamics in nanomagnets

    International Nuclear Information System (INIS)

    Bertotti, G.; Serpico, C.; Mayergoyz, I.D.; Bonin, R.; D'Aquino, M.

    2007-01-01

    An overview is given of the various approaches that have been proposed for the interpretation of spin-transfer-driven magnetization dynamics. Models of critical currents and critical fields for switching as well as for the onset of magnetization oscillations are discussed, together with methods for the construction of field-current stability diagrams. Finally, the role of thermal fluctuations is analyzed. Particular emphasis is given to the study of uniformly magnetized nanomagnets, which represents an essential step before moving to the numerical computation of more complex micromagnetic configurations

  7. Current-induced magnetization dynamics in nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Bertotti, G. [INRIM-Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, 10135 Turin (Italy)]. E-mail: g.bertotti@inrim.it; Serpico, C. [Department of Electrical Engineering, Universita degli Studi Federico II, Via Claudio 21, 80125 Naples (Italy); Mayergoyz, I.D. [Department of Electrical and Computer Engineering, University of Maryland, College Park, MD 20742 (United States); Bonin, R. [INRIM-Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, 10135 Turin (Italy); D' Aquino, M. [Department of Electrical Engineering, Universita degli Studi Federico II, Via Claudio 21, 80125 Naples (Italy)

    2007-09-15

    An overview is given of the various approaches that have been proposed for the interpretation of spin-transfer-driven magnetization dynamics. Models of critical currents and critical fields for switching as well as for the onset of magnetization oscillations are discussed, together with methods for the construction of field-current stability diagrams. Finally, the role of thermal fluctuations is analyzed. Particular emphasis is given to the study of uniformly magnetized nanomagnets, which represents an essential step before moving to the numerical computation of more complex micromagnetic configurations.

  8. Strain-controlled nonvolatile magnetization switching

    Science.gov (United States)

    Geprägs, S.; Brandlmaier, A.; Brandt, M. S.; Gross, R.; Goennenwein, S. T. B.

    2014-11-01

    We investigate different approaches towards a nonvolatile switching of the remanent magnetization in single-crystalline ferromagnets at room temperature via elastic strain using ferromagnetic thin film/piezoelectric actuator hybrids. The piezoelectric actuator induces a voltage-controllable strain along different crystalline directions of the ferromagnetic thin film, resulting in modifications of its magnetization by converse magnetoelastic effects. We quantify the magnetization changes in the hybrids via ferromagnetic resonance spectroscopy and superconducting quantum interference device magnetometry. These measurements demonstrate a significant strain-induced change of the magnetization, limited by an inefficient strain transfer and domain formation in the particular system studied. To overcome these obstacles, we address practicable engineering concepts and use a model to demonstrate that a strain-controlled, nonvolatile magnetization switching should be possible in appropriately engineered ferromagnetic/piezoelectric actuator hybrids.

  9. Deformation of ferrofluid marbles in the presence of a permanent magnet.

    Science.gov (United States)

    Nguyen, Nam-Trung

    2013-11-12

    This paper investigates the deformation of ferrofluid marbles in the presence of a permanent magnet. Ferrofluid marbles are formed using a water-based ferrofluid and 1 μm hydrophobic polytetrafluoride particles. A marble placed on a Teflon coated glass plate deforms under gravity. In the presence of a permanent magnet, the marble is further deformed with a larger contact area. The geometric parameters are normalized by the radius of an undistorted spherical marble. The paper first discusses a scaling relationship between the dimensionless radius of the contact area as well as the dimensionless height and the magnetic Bond number. The dimensionless contact radius is proportional to the fourth root of the magnetic bond number. The dimensionless height scales with the inverse square root of the magnetic Bond number. In the case of a moving marble dragged by a permanent magnet, the deformation is evaluated as the difference between advancing and receding curvatures of the top view. The dimensionless height and the contact diameter of the marble do not significantly depend on the speed or the capillary number. The scaling analysis and experimental data show that the deformation is proportional to the capillary number.

  10. Spin Orbit Interaction Engineering for beyond Spin Transfer Torque memory

    Science.gov (United States)

    Wang, Kang L.

    Spin transfer torque memory uses electron current to transfer the spin torque of electrons to switch a magnetic free layer. This talk will address an alternative approach to energy efficient non-volatile spintronics through engineering of spin orbit interaction (SOC) and the use of spin orbit torque (SOT) by the use of electric field to improve further the energy efficiency of switching. I will first discuss the engineering of interface SOC, which results in the electric field control of magnetic moment or magneto-electric (ME) effect. Magnetic memory bits based on this ME effect, referred to as magnetoelectric RAM (MeRAM), is shown to have orders of magnitude lower energy dissipation compared with spin transfer torque memory (STTRAM). Likewise, interests in spin Hall as a result of SOC have led to many advances. Recent demonstrations of magnetization switching induced by in-plane current in heavy metal/ferromagnetic heterostructures have been shown to arise from the large SOC. The large SOC is also shown to give rise to the large SOT. Due to the presence of an intrinsic extraordinarily strong SOC and spin-momentum lock, topological insulators (TIs) are expected to be promising candidates for exploring spin-orbit torque (SOT)-related physics. In particular, we will show the magnetization switching in a chromium-doped magnetic TI bilayer heterostructure by charge current. A giant SOT of more than three orders of magnitude larger than those reported in heavy metals is also obtained. This large SOT is shown to come from the spin-momentum locked surface states of TI, which may further lead to innovative low power applications. I will also describe other related physics of SOC at the interface of anti-ferromagnetism/ferromagnetic structure and show the control exchange bias by electric field for high speed memory switching. The work was in part supported by ERFC-SHINES, NSF, ARO, TANMS, and FAME.

  11. Radiative Heat Transfer with Nanowire/Nanohole Metamaterials for Thermal Energy Harvesting Applications

    Science.gov (United States)

    Chang, Jui-Yung

    Recently, nanostructured metamaterials have attracted lots of attentions due to its tunable artificial properties. In particular, nanowire/nanohole based metamaterials which are known of the capability of large area fabrication were intensively studied. Most of the studies are only based on the electrical responses of the metamaterials; however, magnetic response, is usually neglected since magnetic material does not exist naturally within the visible or infrared range. For the past few years, artificial magnetic response from nanostructure based metamaterials has been proposed. This reveals the possibility of exciting resonance modes based on magnetic responses in nanowire/nanohole metamaterials which can potentially provide additional enhancement on radiative transport. On the other hand, beyond classical far-field radiative heat transfer, near-field radiation which is known of exceeding the Planck's blackbody limit has also become a hot topic in the field. This PhD dissertation aims to obtain a deep fundamental understanding of nanowire/nanohole based metamaterials in both far-field and near-field in terms of both electrical and magnetic responses. The underlying mechanisms that can be excited by nanowire/nanohole metamaterials such as electrical surface plasmon polariton, magnetic hyperbolic mode, magnetic polariton, etc., will be theoretically studied in both far-field and near-field. Furthermore, other than conventional effective medium theory which only considers the electrical response of metamaterials, the artificial magnetic response of metamaterials will also be studied through parameter retrieval of far-field optical and radiative properties for studying near-field radiative transport. Moreover, a custom-made AFM tip based metrology will be employed to experimentally study near-field radiative transfer between a plate and a sphere separated by nanometer vacuum gaps in vacuum. This transformative research will break new ground in nanoscale radiative heat

  12. [Multiple coil pulsed magnetic resonance method to measure the SSC bending magnet multipole moments

    International Nuclear Information System (INIS)

    Clark, W.G.

    1990-01-01

    The main emphasis has been to continue development of the high frequency (to 300 MHz) instrumentation, to test the system on a prototype bending magnet, construct the high frequency 32-channel electronics and probes, to seek industrial partners for technology transfer and commercial exploitation, and to do computer simulations for optimizing design parameters. Experience gained from tests made on a dipole magnet at Lawrence Berkeley Laboratory was extremely valuable and has resulted in substantial modifications to the original design

  13. Effects of magnetic, radiation and chemical reaction on unsteady heat and mass transfer flow of an oscillating cylinder

    Science.gov (United States)

    Ahmed, Rubel; Rana, B. M. Jewel; Ahmmed, S. F.

    2017-06-01

    The effects of magnetic, radiation and chemical reaction parameters on the unsteady heat and mass transfer boundary layer flow past an oscillating cylinder is considered. The dimensionless momentum, energy and concentration equations are solved numerically by using explicit finite difference method with the help of a computer programming language Compaq visual FORTRAN 6.6a. The obtained results of this study have been discussed for different values of well-known parameters with different time steps. The effect of these parameters on the velocity field, temperature field and concentration field, skin-friction, Nusselt number, streamlines and isotherms has been studied and results are presented by graphically represented by the tabular form quantitatively. The stability and convergence analysis of the solution parameters that have been used in the mathematical model have been tested.

  14. Ultra-fast magnetization reversal in magnetic nano-pillars by spin-polarized current

    Energy Technology Data Exchange (ETDEWEB)

    Devolder, T. [Institut d' Electronique Fondamentale, UMR 8622 CNRS, Universite Paris Sud, Ba-circumflex timent 220, 91405 Orsay (France)]. E-mail: thibaut.devolder@ief.u-psud.fr; Tulapurkar, A. [NanoElectronics Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba 305-8568 (Japan); CREST, Japan Science and Technology Corporation, 4-1-8 Honcho, Kawaguchi 332-0012 (Japan); Yagami, K. [SSNC, Semiconductor Technology Development Group, SONY Corporation, Atsugi, Kanagawa 243-0014 (Japan); Crozat, P. [Institut d' Electronique Fondamentale, UMR 8622 CNRS, Universite Paris Sud, Ba-circumflex timent 220, 91405 Orsay (France); Chappert, C. [Institut d' Electronique Fondamentale, UMR 8622 CNRS, Universite Paris Sud, Ba-circumflex timent 220, 91405 Orsay (France); Fukushima, A. [NanoElectronics Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba 305-8568 (Japan); CREST, Japan Science and Technology Corporation, 4-1-8 Honcho, Kawaguchi 332-0012 (Japan); Suzuki, Y. [NanoElectronics Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba 305-8568 (Japan); CREST, Japan Science and Technology Corporation, 4-1-8 Honcho, Kawaguchi 332-0012 (Japan)

    2005-02-01

    We study the speed limitations of the magnetization switching resulting from spin transfer in pillar-shaped CoFe/Cu/CoFe spin valves. The quasi-static critical currents are Ic-=-2mA for the antiparallel (AP) to parallel (P) configuration and Ic+=+4.6mA for the P to AP transition. Current pulses of duration down to 100ps and amplitude of 4I{sub c} trigger switching at 300K. The switching is probabilistic for lower current pulses. The P to AP transition speed is not much temperature dependant from 50 to 300K. In contrast, the AP to P transition is thermally inhibited and is much faster at 150K than at 300K. This thermal inhibition highlights the importance of the macrospin coherency and of the thermally excited spin waves with finite wave vector parallel to the magnetization. Our results validate spin-transfer switching for fast memory applications.

  15. Ultra-fast magnetization reversal in magnetic nano-pillars by spin-polarized current

    International Nuclear Information System (INIS)

    Devolder, T.; Tulapurkar, A.; Yagami, K.; Crozat, P.; Chappert, C.; Fukushima, A.; Suzuki, Y.

    2005-01-01

    We study the speed limitations of the magnetization switching resulting from spin transfer in pillar-shaped CoFe/Cu/CoFe spin valves. The quasi-static critical currents are Ic-=-2mA for the antiparallel (AP) to parallel (P) configuration and Ic+=+4.6mA for the P to AP transition. Current pulses of duration down to 100ps and amplitude of 4I c trigger switching at 300K. The switching is probabilistic for lower current pulses. The P to AP transition speed is not much temperature dependant from 50 to 300K. In contrast, the AP to P transition is thermally inhibited and is much faster at 150K than at 300K. This thermal inhibition highlights the importance of the macrospin coherency and of the thermally excited spin waves with finite wave vector parallel to the magnetization. Our results validate spin-transfer switching for fast memory applications

  16. RADIALLY MAGNETIZED PROTOPLANETARY DISK: VERTICAL PROFILE

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Matthew [Department of Physics, University of Toronto, 60 St. George St., Toronto, ON M5S 1A7 (Canada); Thompson, Christopher [Canadian Institute for Theoretical Astrophysics, 60 St. George St., Toronto, ON M5S 3H8 (Canada)

    2015-11-10

    This paper studies the response of a thin accretion disk to an external radial magnetic field. Our focus is on protoplanetary disks (PPDs), which are exposed during their later evolution to an intense, magnetized wind from the central star. A radial magnetic field is mixed into a thin surface layer, wound up by the disk shear, and pushed downward by a combination of turbulent mixing and ambipolar and ohmic drift. The toroidal field reaches much greater strengths than the seed vertical field that is usually invoked in PPD models, even becoming superthermal. Linear stability analysis indicates that the disk experiences the magnetorotational instability (MRI) at a higher magnetization than a vertically magnetized disk when both the effects of ambipolar and Hall drift are taken into account. Steady vertical profiles of density and magnetic field are obtained at several radii between 0.06 and 1 AU in response to a wind magnetic field B{sub r} ∼ (10{sup −4}–10{sup −2})(r/ AU){sup −2} G. Careful attention is given to the radial and vertical ionization structure resulting from irradiation by stellar X-rays. The disk is more strongly magnetized closer to the star, where it can support a higher rate of mass transfer. As a result, the inner ∼1 AU of a PPD is found to evolve toward lower surface density. Mass transfer rates around 10{sup −8} M{sub ⊙} yr{sup −1} are obtained under conservative assumptions about the MRI-generated stress. The evolution of the disk and the implications for planet migration are investigated in the accompanying paper.

  17. Mix Proportion Design of Asphalt Concrete

    Science.gov (United States)

    Wu, Xianhu; Gao, Lingling; Du, Shoujun

    2017-12-01

    Based on the gradation of AC and SMA, this paper designs a new type of anti slide mixture with two types of advantages. Chapter introduces the material selection, ratio of ore mixture ratio design calculation, and determine the optimal asphalt content test and proportioning design of asphalt concrete mix. This paper introduces the new technology of mix proportion.

  18. Parameters of glucose metabolism and the aging brain: a magnetization transfer imaging study of brain macro- and micro-structure in older adults without diabetes.

    Science.gov (United States)

    Akintola, Abimbola A; van den Berg, Annette; Altmann-Schneider, Irmhild; Jansen, Steffy W; van Buchem, Mark A; Slagboom, P Eline; Westendorp, Rudi G; van Heemst, Diana; van der Grond, Jeroen

    2015-08-01

    Given the concurrent, escalating epidemic of diabetes mellitus and neurodegenerative diseases, two age-related disorders, we aimed to understand the relation between parameters of glucose metabolism and indices of pathology in the aging brain. From the Leiden Longevity Study, 132 participants (mean age 66 years) underwent a 2-h oral glucose tolerance test to assess glucose tolerance (fasted and area under the curve (AUC) glucose), insulin sensitivity (fasted and AUC insulin and homeostatic model assessment of insulin sensitivity (HOMA-IS)) and insulin secretion (insulinogenic index). 3-T brain MRI was used to detect macro-structural damage (atrophy, white matter hyper-intensities, infarcts and/or micro-bleeds) and magnetization transfer imaging (MTI) to detect loss of micro-structural homogeneity that remains otherwise invisible on conventional MRI. Macro-structurally, higher fasted glucose was significantly associated with white matter atrophy (P = 0.028). Micro-structurally, decreased magnetization transfer ratio (MTR) peak height in gray matter was associated with higher fasted insulin (P = 0.010), AUCinsulin (P = 0.001), insulinogenic index (P = 0.008) and lower HOMA-IS index (P glucose was associated with macro-structural damage, impaired insulin action was associated more strongly with reduced micro-structural brain parenchymal homogeneity. These findings offer some insight into the association between different parameters of glucose metabolism (impairment of which is characteristic of diabetes mellitus) and brain aging.

  19. Transfer of patients--from the spoke to the hub.

    LENUS (Irish Health Repository)

    Deasy, C

    2012-02-03

    We describe the nature, frequency, and characteristics of transfers to a regional centre. This was a three month prospective descriptive study of all transfers into the hospital through the ED and a further sample survey of 100 patients received into the resuscitation room over a 2 year period. 105 patient transfers were surveyed over the three month period. A significant number (43 patients) arrived at the ED without prior notification being received by ED staff, a proportion (7 patients) warranting resuscitation room assessment. The rate of Doctor Transfer was 22%. Of the 23 patients that warranted assessment in the resuscitation room 10 were unaccompanied by a Doctor and 5 were unaccompanied by either a Doctor or a Nurse. 11% of transfers had no transfer letter or radiographs. Only 51% of transferred patients had an IV line in situ. 4 out of the 8 transfers into the resuscitation room performed by interns were associated with adverse events. There continues to be problems with the quality of care that these patients receive. Clinicians must be actively involved in the development of regional transfer protocols and interfacility agreements to ensure the safe transfer of patients to definitive care.

  20. Measurement of magnetization of Ga1−xMnxAs by ferromagnetic resonance

    International Nuclear Information System (INIS)

    Hagmann, J.A.; Traudt, K.; Zhou, Y.Y.; Liu, X.; Dobrowolska, M.; Furdyna, J.K.

    2014-01-01

    In this paper, we extend ferromagnetic resonance (FMR) studies of thin layers of the ferromagnetic semiconductor Ga 1−x Mn x As to the analysis of the integrated intensity of the resonance in order to obtain information on the total spin in the sample directly involved in ferromagnetically-ordered magnetization. A theoretical model is proposed for the dependences of the FMR integrated intensity and linewidth on the orientation of the applied magnetic field as the field direction is varied from in-plane to normal-to-the-plane of the Ga 1−x Mn x As layer. The strain-induced magnetic anisotropy of Ga 1−x Mn x As presents a significant challenge to conventional FMR linewidth and integrated intensity models. The new model predicts that the integrated FMR intensity is proportional to the saturation magnetization M S of the sample, with the constant of proportionality varying as a function of the polar and azimuthal angles of the applied magnetic field. The angular and temperature behaviors of the integrated intensity and linewidth of the FMR predicted by the proposed model are in good qualitative agreement with measurements. - Highlights: • We extend ferromagnetic resonance to the analysis of total magnetization of thin film Ga 1−x Mn x As. • We formulate a theoretical model for FMR integrated intensity and linewidth. • The model predicts that integrated FMR intensity is proportional to magnetization. • Predictions made by the model are in good qualitative agreement with measurements