WorldWideScience

Sample records for magnetic resonance diagnostic

  1. Nuclear magnetic resonance diagnostic apparatus

    International Nuclear Information System (INIS)

    Sugimoto, H.

    1985-01-01

    Nuclear magnetic resonance diagnostic apparatus including a coil for generating a gradient field in a plane perpendicular to a static magnetic field, means for controlling the operation of the coil to rotationally shift in angular steps the gradient direction of the gradient field at an angle pitch of some multiple of the unit index angle through a plurality of rotations to assume all the shift positions of the gradient direction, a rough image reconstructor for reconstructing a rough tomographic image on the basis of nuclear magnetic resonance signals acquired during a rotation of the second gradient magnetic field, a rough image display for depicting the rough tomographic image, a final image reconstructor for reconstructing a final tomographic image on the basis of all nuclear magnetic resonance signals corresponding to all of the expected rotation shift positions acquired during a plurality of rotations and a final image display for depicting the final tomographic image

  2. Diagnostic apparatus employing nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Hoshino, K.; Yamada, N.; Yoshitome, E.; Matsuura, H.

    1987-01-01

    An NMR diagnostic apparatus is described comprising means for applying a primary magnetic field to a subject; means for applying RF pulses to the subject to give nuclear magnetic resonance to the nuclei of atoms in the subject; means for applying gradient magnetic fields to project an NMR signal of the nuclei at least in one direction; means for observing the NMR signal projected by the gradient magnetic fields applying means; and arithmetic means for constructing a distribution of information on resonance energy as an image from an output signal from the observing means; wherein the gradient magnetic fields applying means comprises means for applying the gradient magnetic fields at a predetermined time and for not applying the gradient magnetic fields at another predetermined time, during the time period of one view; and wherein the gradient magnetic fields applying means further comprises means for measuring the NMR signal during the predetermined time when the gradient magnetic fields are applied, and means for measuring the intensity of the primary magnetic field during the other predetermined time when no gradient magnetic fields are applied

  3. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    Science.gov (United States)

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  4. 21 CFR 892.1000 - Magnetic resonance diagnostic device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Magnetic resonance diagnostic device. 892.1000 Section 892.1000 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1000 Magnetic resonance diagnostic...

  5. Magnetic resonance spectroscopy as a diagnostic modality for carcinoma thyroid

    International Nuclear Information System (INIS)

    Gupta, Nikhil; Kakar, Arun K.; Chowdhury, Veena; Gulati, Praveen; Shankar, L. Ravi; Vindal, Anubhav

    2007-01-01

    Aim: The aim of this study was to observe the findings of magnetic resonance spectroscopy of solitary thyroid nodules and its correlation with histopathology. Materials and methods: In this study, magnetic resonance spectroscopy was carried out on 26 patients having solitary thyroid nodules. Magnetic resonance spectroscopy (MRS) was performed on a 1.5 T super conductive system with gradient strength of 33 mTs. Fine needle aspiration cytology was done after MRS. All 26 patients underwent surgery either because of cytopathologically proven malignancy or because of cosmetic reasons. Findings of magnetic resonance spectroscopy were compared with histopathology of thyroid specimens. Results and conclusion: It was seen that presence or absence of choline peak correlates very well with presence or absence of malignant foci with in the nodule (sensitivity = 100%; specificity = 88.88%). These results indicate that magnetic resonance spectroscopy may prove to be an useful diagnostic modality for carcinoma thyroid

  6. Magnetic resonance tomography of renal allografts - Diagnostic possibilities

    International Nuclear Information System (INIS)

    Dewey, C.; Luening, M.

    1988-01-01

    It is the aim of the use of magnetic resonance tomography (MRT) to reduce the existing insufficiency in imaging diagnostics of complications after kidney transplantation. The topical status of examination technique is presented and the criteria of normal and pathological MRT findings are described in detail. (author)

  7. Magnetic resonance imaging of the wrist: Diagnostic performance statistics

    International Nuclear Information System (INIS)

    Hobby, Jonathan L.; Tom, Brian D.M.; Bearcroft, Philip W.P.; Dixon, Adrian K.

    2001-01-01

    AIM: To review the published diagnostic performance statistics for magnetic resonance imaging (MRI) of the wrist for tears of the triangular fibrocartilage complex, the intrinsic carpal ligaments, and for osteonecrosis of the carpal bones. MATERIALS AND METHODS: We used Medline and Embase to search the English language literature. Studies evaluating the diagnostic performance of MRI of the wrist in living patients with surgical confirmation of MR findings were identified. RESULTS: We identified 11 studies reporting the diagnostic performance of MRI for tears of the triangular fibrocartilage complex for a total of 410 patients, six studies for the scapho-lunate ligament (159 patients), six studies for the luno-triquetral ligament (142 patients) and four studies (56 patients) for osteonecrosis of the carpal bones. CONCLUSIONS: Magnetic resonance imaging is an accurate means of diagnosing tears of the triangular fibrocartilage and carpal osteonecrosis. Although MRI is highly specific for tears of the intrinsic carpal ligaments, its sensitivity is low. The diagnostic performance of MRI in the wrist is improved by using high-resolution T2* weighted 3D gradient echo sequences. Using current imaging techniques without intra-articular contrast medium, magnetic resonance imaging cannot reliably exclude tears of the intrinsic carpal ligaments. Hobby, J.L. (2001)

  8. Magnetic resonance tomography in oncological diagnostics

    International Nuclear Information System (INIS)

    Lien, Hans Henrik; Taksdal, Ingeborg

    2000-01-01

    MR is well suited for imaging in patients with malignant disease. It is the most sensitive and most specific method in the detection of skeletal metastases. It clearly demonstrates the extent of primary bone tumours and also reveals skip metastases and invasion into neighbouring joints, hence it is an important procedure when surgery of a bone tumour is planned. In case of a soft tissue tumour, MR is the preferable imaging modality because it demonstrates the anatomy and reveals the different tissue constituents. MR is the best method to show tumour manifestations in the central nervous system and it supplements cerebrospinal fluid examination in the detection of meningeal metastasis. MR is the method of choice if there is a cord compression. MR imaging is important in gynaecology and oncology. Cost savings have been reported due to reduced use of other diagnostic tests and expensive surgical procedures. New and faster techniques allow examination of the total body in less than 45 minutes. We expect that MR imaging will be increasingly used in the future in patients with malignant disease

  9. The use of magnetic resonance tomography in gastrointestinal diagnostics

    International Nuclear Information System (INIS)

    Geitung, Jonn Terje

    2000-01-01

    Background: Magnetic resonance imaging (MRI) is a promising method for examination of the gastrointestinal tract. In this article we present the present status and potential of MRI. Material and method: The review is based on personal experience and selected published, international papers. Results: Magnetic resonance cholangio-pancreatography (MRCP) and MRI of the liver are well documented examinations which are widely performed. These examinations partly replace existing modalities such as CT and ERCP and represent additional possibilities for examining this anatomic area. MRI is not as yet accepted as the standard examination of the pancreas, but it is regarded as comparable to CT. The adrenals may be examined even more accurately with MRI than with CT. MRI examinations of the oesophagus and gastric ventricle seem promising, but it should be said that they are in an early and not well document phase. MRI of the small and large bowels is not common. With the exception of preoperative staging of rectal cancers, it is still experimental. MR angiography, functional MRI studies and perfusion studies are not yet common in abdominal diseases. We may, however, believe that they will become important diagnostic tools. Interpretation: MRI is rapidly increasing its share of gastrointestinal imaging examinations. This is mainly due to the increased speed of newer machines. The diagnostic quality has improved and will improve more. It is thus likely that MRI will, in a large amount of abdominal imaging, replace CT and to some extent other diagnostic modalities. It is, however, not possible to replace CT for emergencies and we will probably look forward to more and better imaging with more diagnostic modalities in the future

  10. Basic artefacts of diagnostic imaging by the magnetic resonance method

    International Nuclear Information System (INIS)

    Vitak, T.; Seidl, Z.; Obenberger, J.; Vaneckova, M.; Danes, J.; Krasensky, J.; Peterkova, V

    2000-01-01

    Artefacts in diagnostic imaging are defined as a geometric or anatomic misrepresentation of the reality by the image formed. The article deals with artefacts due to field and frequency shifts, in particular due to the water-fat chemical shift and due to magnetic susceptibility. The physical nature of the artefacts is explained and their diagnostic significance is discussed. (P.A.)

  11. Safety guidelines for magnetic resonance diagnostic facilities (1991)

    International Nuclear Information System (INIS)

    1992-01-01

    These guidelines provide information on levels and health effects of exposure to magnetic and radiofrequency electromagnetic fields associated with magnetic resonance (MR) devices, and on precautions to minimize effects on patients, staff, and the general public. The guidelines are for use by regulatory authorities, MR users and health professionals. 22 refs., 1 tab

  12. Diagnostic imaging of psoriatic arthritis. Part II: magnetic resonance imaging and ultrasonography

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2016-06-01

    Full Text Available Plain radiography reveals specific, yet late changes of advanced psoriatic arthritis. Early inflammatory changes are seen both on magnetic resonance imaging and ultrasound within peripheral joints (arthritis, synovitis, tendons sheaths (tenosynovitis, tendovaginitis and entheses (enthesitis, enthesopathy. In addition, magnetic resonance imaging enables the assessment of inflammatory features in the sacroiliac joints (sacroiliitis, and the spine (spondylitis. In this article, we review current opinions on the diagnostics of some selective, and distinctive features of psoriatic arthritis concerning magnetic resonance imaging and ultrasound and present some hypotheses on psoriatic arthritis etiopathogenesis, which have been studied with the use of magnetic resonance imaging. The following elements of the psoriatic arthritis are discussed: enthesitis, extracapsular inflammation, dactylitis, distal interphalangeal joint and nail disease, and the ability of magnetic resonance imaging to differentiate undifferentiated arthritis, the value of whole-body magnetic resonance imaging and dynamic contrast-enhanced magnetic resonance imaging.

  13. Magnetic resonance imaging in the diagnostics of multiple sclerosis

    International Nuclear Information System (INIS)

    Larsen, J.P.; Tjoerstad, K.; Kaass, B.; Oedegaard, H.

    1987-01-01

    Multiple sclerosis is an important and frequent neurological disease and the diagnosis might be difficult. The clinical criteria of multiple sclerosis and the role of laboratory examinations in the diagnosis of the disease are discussed. In particular the help offered by the magnetic resonance imaging method is the subject of this paper. Three patients are reported and discussed

  14. Design of a Magnetic Resonance-Safe Haptic Wrist Manipulator for Movement Disorder Diagnostics

    NARCIS (Netherlands)

    Bode, Dyon; Mugge, Winfred; Schouten, Alfred C.; van Rootselaar, Anne-Fleur; Bour, Lo J.; van der Helm, Frans C. T.; Lammertse, Piet

    2017-01-01

    Tremor, characterized by involuntary and rhythmical movements, is the most common movement disorder. Tremor can have peripheral and central oscillatory components which properly assessed may improve diagnostics. A magnetic resonance (MR)-safe haptic wrist manipulator enables simultaneous measurement

  15. [Dementias: diagnostic contribution of imaging and proton magnetic resonance spectroscopy].

    Science.gov (United States)

    Arana, E; Martínez-Granados, B; Marti-Bonmati, L; Martínez-Bisbal, M C; Gil, A; Blasco, C; Celda, B

    2007-06-01

    The objective is analyze the complementarity between 1H magnetic resonance spectroscopy (MRS) and magnetic resonance (MR) imaging in the global diagnosis of Alzheimer's disease (AD) or vascular dementia (VD). We studied 168 patients with cognitive impairment from AD, VD, mild cognitive impairment (MCI) and major depression. All patients were evaluated by brain MR imaging and MRS using two sample volumes localized at right medial temporal gyrus and posterior parietal gyrus. Metabolites analyzed were N-acetylaspartate (NAA), myo-Inositol (mI), Choline (Cho) and creatine (Cr), as standard references for obtaining the Co/Cr, mI/Cr and NAA/Cr ratios. Imaging and spectroscopy alterations were graded from 0 to 4 and the average of both was used to draw ROC and SROC curves. Area under ROC curve (Az) was used as a measure of discriminative ability. Combination of MR imaging and MRS significantly improved AD diagnosis (Global Az: 0.722 vs. MR imaging Az: 0.624; p: 0.003). However, the combination of MR imaging and MRS did not improve VD diagnosis. SROC curve obtained for the diagnosis of global dementia was Az: 0.6658 with 0.67 sensitivity and 0.65 specificity. Combination of both MR techniques significantly improved AD diagnosis versus MR imaging alone. More studies are needed to enhance VD classification. Metabolic data found by MRS can be useful to differentiate cognitive impairment

  16. Radiofrequency power deposition during magnetic resonance diagnostic examinations

    International Nuclear Information System (INIS)

    Grandolfo, M.; Vecchia, P.

    1988-01-01

    Magnetic Resonance Imaging and Spectroscopy (MRI, MRS) require that subjects be exposed to radiofrequency field, and the corresponding energy absorption leads to tissue heating. The main question, thus, to be considered in connection to safety and health aspects is related to the specific absorption rate (SAR) in the imaged subject and the exposure durations which might put a practical limit on the pulse sequence which can be used. In this paper some models and experimental results for radiofrequency power deposition in MRI and MRS machines are reviewed. Models show that energy dissipation is a function of the frequency, RF incident power density, exposure duration, coupling between the RF coil and the subject, and several properties of the exposed tissue, including conductivity, dielectric constant, specific gravity, size, and orientation relative to the field polarization. The ability of the body's normal thermoregulatory responses to cope with high levels of RF energy deposition must be also taken into account

  17. The diagnostic accuracy of acetabular labral tears using magnetic resonance imaging and magnetic resonance arthrography: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Toby O. [University of East Anglia, Faculty of Health, Queen' s Building, Norwich (United Kingdom); Hilton, Gemma [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P.; Donell, Simon T. [Norfolk and Norwich University Hospital, University of East Anglia, Norwich (United Kingdom); Hing, Caroline B. [St. George' s Hospital, London (United Kingdom)

    2011-04-15

    Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have been advocated for the diagnosis of acetabular labral tears. The purpose of this study was to determine the sensitivity and specificity of MRI and MRA in diagnosing acetabular labral tears using meta-analysis. Pertinent published and unpublished literature databases were reviewed. A two-by-two table was constructed to calculate the sensitivity and specificity of MRI or MRA investigations against surgical outcomes. Pooled sensitivity and specificity and Receiver Operating Characteristic curve (ROC) evaluations were performed. Methodological quality of each study was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) tool. Nineteen papers assessing 881 hips were reviewed. Conventional MRI was assessed in 13 studies and MRA was assessed in 16 studies. Whilst both MRI (0.5-3T) and MRA (0.5-3T) presented with a moderate sensitivity and specificity (sensitivity 66%, 87%; specificity 79%, 64%), diagnostic accuracy of MRA appeared to be superior to MRI in detecting acetabular labral tears on ROC curve interpretation. The literature poorly described population characteristics, assessor blinding, with limited sample sizes. MRI and MRA may be useful adjuncts in the diagnosis of acetabular labral tears in adults. MRA appears to be superior to conventional MRI. (orig.)

  18. Diagnostic utility of candidate definitions for demonstrating axial spondyloarthritis on magnetic resonance imaging of the spine

    DEFF Research Database (Denmark)

    Weber, Ulrich; Zhao, Zheng; Rufibach, Kaspar

    2015-01-01

    OBJECTIVE: A recent consensus statement has suggested ≥3 corner inflammatory lesions (CILs) or several corner fatty lesions (CFLs) as candidate criteria indicative of axial spondyloarthritis (SpA) on magnetic resonance imaging (MRI) of the spine. The aim of this study was to evaluate the diagnostic...

  19. Functional magnetic resonance imaging of the truncus pulmonalis. Principles of magnetic resonance flux measurements for pulmonal hypertension diagnostics

    International Nuclear Information System (INIS)

    Abolmaali, N.

    2006-01-01

    This book gives a detailed introduction into the use of magnetic resonance flux measurements for the examination of pulmonal circulation. It presents the results of phantom experiments and evaluates and verifies sequence techniques optimised for the examination of the pulmonary circulation. This is followed by a description of an elegant experimental design for the quantification of pulmonal hypertension which is unique in its kind. The model can predict the consequences of acute, resistance-related pulmonal hypertension in a reproducible and reversible manner. It thus provides a means of evaluating pulmonal applications of magnetic resonance imaging. The idea for these studies and its implementation are an outstanding example of teamwork and interdisciplinary cooperation. Applying the results to the patient after the statistical analysis is only a small step. The book presents the results of extensive normal value studies which will make it possible to use the measurement technology in paediatric cardiology. Its range of application also includes congenital heart defects, especially ventricular septal defects and primary as well as secondary forms of pulmonal hypertension. It is not only suitable for primary diagnostics but also for post-treatment follow-up and assessment of patients' progress

  20. Magnetic resonance imaging and spectroscopy- emerging trends in medical diagnostics and therapy

    International Nuclear Information System (INIS)

    Deshmukh, Sudha

    1997-01-01

    A dramatic acceleration in the application of magnetic resonance techniques in the field of medical sciences has been witnessed over the past decade. Magnetic Resonance Imaging (MRI) has been called the most significant development since the discovery of x-rays. As a method of visualizing cross-sectional anatomy, MRI is without peer. MRI images can now provide in-vivo anatomical details that were earlier available only with invasive procedures. Yet, despite its extraordinary potential, MRI has had limited success, if any, in tissue characterization using the three image parameters T 1 , T 2 and proton density ρ. MR spectroscopy has however bridged this gap to a large extent and opened up the possibility of studying in vivo chemistry. In the present article an attempt has been made to give a brief account of the application of magnetic resonance imaging and spectroscopy in medical diagnostics and therapy. The basic principles pertaining to MRI and MRS are also discussed in brief. (author)

  1. Clinical diagnostic criteria of multiple sclerosis: the role of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Belair, M.; Girard, M.

    2004-01-01

    The objective of this article is to summarize the diagnostic criteria recommended by the International Panel on the Diagnosis of Multiple Sclerosis in 2001. The recommendations of another working group, the Consortium of Multiple Sclerosis Centers Consensus Meeting, which met in Vancouver in 2001, concerning the diagnosis and follow-up of patients with multiple sclerosis are also presented in an effort to standardize the protocols for magnetic resonance imaging of these patients. (author)

  2. Magnetic resonance imaging in local staging of endometrial carcinoma: diagnostic performance, pitfalls, and literature review.

    Science.gov (United States)

    Zandrino, Franco; La Paglia, Ernesto; Musante, Francesco

    2010-01-01

    To assess the diagnostic accuracy of magnetic resonance imaging in local staging of endometrial carcinoma, and to review the results and pitfalls described in the literature. Thirty women with a histological diagnosis of endometrial carcinoma underwent magnetic resonance imaging. Unenhanced T2-weighted and dynamic contrast-enhanced Ti-weighted sequences were obtained. Hysterectomy and salpingo-oophorectomy was performed in all patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for the detection of deep myometrial and cervical infiltration. For deep myometrial infiltration T2-weighted sequences reached a sensitivity of 85%, specificity of 76%, PPV of 73%, NVP of 87%, and accuracy of 80%, while contrast-enhanced scans reached a sensitivity of 90%, specificity of 80%, PPV of 82%, NPV of 89%, and accuracy of 85%. For cervical infiltration T2-weighted sequences reached a sensitivity of 75%, specificity of 88%, PPV of 50%, NPV of 96%, and accuracy of 87%, while contrast-enhanced scans reached a sensitivity of 100%, specificity of 94%, PPV of 75%, NPV of 100%, and accuracy of 95%. Unenhanced and dynamic gadolinium-enhanced magnetic resonance allows accurate assessment of myometrial and cervical infiltration. Information provided by magnetic resonance imaging can define prognosis and management.

  3. Fat infiltration on magnetic resonance imaging of the sacroiliac joints has limited diagnostic utility in nonradiographic axial spondyloarthritis

    DEFF Research Database (Denmark)

    Weber, Ulrich; Pedersen, Susanne J; Zubler, Veronika

    2014-01-01

    To explore whether morphological features of fat infiltration (FI) on sacroiliac joint (SIJ) magnetic resonance imaging (MRI) contribute to diagnostic utility in 2 inception cohorts of patients with nonradiographic axial spondyloarthritis (nr-axSpA).......To explore whether morphological features of fat infiltration (FI) on sacroiliac joint (SIJ) magnetic resonance imaging (MRI) contribute to diagnostic utility in 2 inception cohorts of patients with nonradiographic axial spondyloarthritis (nr-axSpA)....

  4. Diagnostic yield of lumbosacral magnetic resonance imaging requested by paediatric urology consultations.

    Science.gov (United States)

    Fernández-Ibieta, M; Rojas Ticona, J; Villamil, V; Guirao Piñera, M J; López García, A; Zambudio Carmona, G

    2017-11-01

    In the historical series, the diagnostic yield of lumbosacral magnetic resonance imaging to rule out occult spinal dysraphism (or occult myelodysplasia), requested by paediatric urology, ranged from 2% to 15%. The aim of this study was to define our cost-effectiveness in children with urinary symptoms and to define endpoints that increase the possibility of finding occult spinal dysraphism. A screening was conducted on patients with urinary dysfunction for whom an magnetic resonance imaging was requested by the paediatric urology clinic, for persistent symptoms after treatment, voiding dysfunction or other clinical or urodynamic findings. We analysed clinical (UTI, daytime leaks, enuresis, voiding dysfunction, urgency, renal ultrasonography, lumbosacral radiography, history of acute urine retention, skin stigma and myalgia) and urodynamic endpoints (hyperactivity or areflexia, voiding dysfunction, interrupted pattern, accommodation value and maximum flow). A univariate analysis was conducted with SPSS 20.0. We analysed 21 patients during the period 2011-2015. The median age was 6 years (3-10). Three patients (14.3%) had occult spinal dysraphism: one spinal lipoma, one filum lipomatosus and one caudal regression syndrome with channel stenosis. The endpoints with statistically significant differences were the myalgias and the history of acute urine retention (66.7% vs. 5.6%, P=.04; OR= 34; 95%CI: 1.5-781 for both endpoints). The diagnostic yield of magnetic resonance imaging requested for children with urinary dysfunctions without skin stigma or neuro-orthopaedic abnormalities is low, although nonnegligible. In this group, the patients with a history of acute urine retention and muscle pain (pain, «cramps») can experience a greater diagnostic yield or positive predictive value. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Magnetic resonance imaging of the shoulder: a review of potential sources of diagnostic errors

    International Nuclear Information System (INIS)

    Carroll, K.W.; Helms, C.A.

    2002-01-01

    Shoulder magnetic resonance (MR) imaging and MR arthrography are frequently utilized in the evaluation of shoulder pain and instability. The clinical scenario and imaging findings may be confusing to clinicians and radiologists and may present diagnostic challenges for those involved in evaluating and treating shoulder pathology. Often rotator cuff and labral abnormalities may be coexistent, clinical manifestations of denervation syndromes may be confusing to clinicians, and normal anatomic variations, imaging pitfalls, and various artifacts may cause dilemmas for the radiologist. This article will review the most frequently encountered mimickers and pitfalls of MR imaging of the shoulder. (orig.)

  6. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  7. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Robertson, Angus

    1990-01-01

    An assessment is made of the clinical benefits of expensive diagnostic technology, such as the magnetic resonance imaging. It is concluded that to most radiologists, magnetic resonance imaging has a definite place in the diagnostic scenario, especially for demonstrating central nervous system lesions in multiple sclerosis. While it is recognized that medical and financial resources are limited, it is emphasised that the cost to society must be balanced against the patient benefit. 17 refs

  8. Magnetic resonance colonography versus colonoscopy as a diagnostic investigation for colorectal cancer: a meta-analysis

    International Nuclear Information System (INIS)

    Purkayastha, S.; Tekkis, P.P.; Athanasiou, T.; Aziz, O.; Negus, R.; Gedroyc, W.; Darzi, A.W.

    2005-01-01

    AIMS: Magnetic resonance colonography (MRC) is emerging as a potential complementary investigation for the diagnosis of colorectal cancer (CRC) and also for benign pathology such as diverticular disease. A meta-analysis reporting the use of MRC is yet to be performed. The aim of this study was to evaluate the diagnostic accuracy of MRC compared with the gold-standard investigation, conventional colonoscopy (CC). METHODS: A literature search was carried out to identify studies containing comparative data between MRC findings and CC findings. Quantitative meta-analysis for diagnostic tests was performed, which included the calculation of independent sensitivities, specificities, diagnostic odds ratios, the construction of summary receiver operating characteristic (SROC) curves, pooled analysis and sensitivity analysis. The study heterogeneity was evaluated by the Q-test using a random-effect model to accommodate the cluster of outcomes between individual studies. RESULTS: In all, 8 comparative studies were identified, involving 563 patients. The calculated pooled sensitivity for all lesions was 75% (95% CI: 47% to 91%), the specificity was 96% (95% CI: 86% to 98%) and the area under the ROC curve was 90% (weighted). On sensitivity analysis, MRC had a better diagnostic accuracy for CRC than for polyps, with a sensitivity of 91% (95% CI: 97% to 91%), a specificity of 98% (95% CI: 66% to 99%) and an area under the ROC curve of 92%. There was no significant heterogeneity between the studies with regard to the diagnostic accuracy of MRC for CRC. CONCLUSION: This meta-analysis suggests that MRC is an imaging technique with high discrimination for cases presenting with colorectal cancer. The exact diagnostic role of MRC needs to be clarified (e.g. suitable for an elderly person with suspected CRC). Further evaluation is necessary to refine its applicability and diagnostic accuracy in comparison with other imaging methods such as computed tomography colonography

  9. Proof-of-the-Concept Study on Mathematically Optimized Magnetic Resonance Spectroscopy for Breast Cancer Diagnostics.

    Science.gov (United States)

    Belkić, Dževad; Belkić, Karen

    2015-06-01

    Magnetic resonance (MR)-based modalities aid breast cancer detection without exposure to ionizing radiation. Magnetic resonance imaging is very sensitive but costly and insufficiently specific. Molecular imaging through magnetic resonance spectroscopy (MRS) can provide information about key metabolites. Here, the measured/encoded time signals cannot be interpreted directly, necessitating mathematics for mapping to the more manageable frequency domain. Conventional applications of MRS are hampered by data analysis via the fast Fourier transform (FFT) and postprocessing by fitting techniques. Most in vivo MRS studies on breast cancer rely upon estimations of total choline (tCHO). These have yielded only incremental improvements in diagnostic accuracy. In vitro studies reveal richer metabolic information for identifying breast cancer, particularly in closely overlapping components of tCHO. Among these are phosphocholine (PC), a marker of malignant transformation of the breast. The FFT cannot assess these congested spectral components. This can be done by the fast Padé transform (FPT), a high-resolution, quantification-equipped method, which we presently apply to noisy MRS time signals consistent with those encoded in breast cancer. The FPT unequivocally and robustly extracted the concentrations of all physical metabolites, including PC. In sharp contrast, the FFT produced a rough envelope spectrum with a few distorted peaks and key metabolites absent altogether. As such, the FFT has poor resolution for these typical MRS time signals from breast cancer. Hence, based on Fourier-estimated envelope spectra, tCHO estimates are unreliable. Using even truncated time signals, the FPT clearly distinguishes noise from true metabolites whose concentrations are accurately extracted. The high resolution of the FPT translates directly into shortened examination time of the patient. These capabilities strongly suggest that by applying the FPT to time signals encoded in vivo from

  10. Assessment of structural lesions in sacroiliac joints enhances diagnostic utility of magnetic resonance imaging in early spondylarthritis

    DEFF Research Database (Denmark)

    Weber, Ulrich; Lambert, Robert G W; Pedersen, Susanne J

    2010-01-01

    To compare the diagnostic utility of T1-weighted and STIR magnetic resonance imaging (MRI) sequences in early spondylarthritis (SpA) using a standardized approach to the evaluation of sacroiliac (SI) joints, and to test whether systematic calibration of readers directed at recognition of abnormal......To compare the diagnostic utility of T1-weighted and STIR magnetic resonance imaging (MRI) sequences in early spondylarthritis (SpA) using a standardized approach to the evaluation of sacroiliac (SI) joints, and to test whether systematic calibration of readers directed at recognition...

  11. Optimized diagnostic performance of brain magnetic resonance imaging in children with idiopathic growth hormone deficiency

    International Nuclear Information System (INIS)

    Rac, M.

    2006-01-01

    Purpose: The aim of this study was to search for correlations between anatomic changes in the pituitary gland and hormonal disturbances in children with short stature. Material and methods: Children with short stature were enrolled when criteria of pituitary growth hormone deficiency were partly or completely met. Magnetic resonance imaging was performed in 87 children and particular attention was given to the pituitary gland. Measurements were compared with pituitary dimensions accepted as normal in the literature. Contrast with GdDTPA was used to visualize the pituitary gland and associated structures (stalk, infundibulum). T1-weighted images in the sagittal and coronal planes were obtained. The results were statistically analyzed with non-parametric tests. Conclusions: 1. Magnetic resonance imaging is a very sensitive method for detecting changes in the pituitary gland and may well be recommended as a method of choice even though the percentage of changes detected with it is rather small. 2. The use of contrast agent may be abandoned to limit costs when searching for cause of growth deficit in children with idiopathic growth hormone deficiency, save for the following cases: hypoplasia or aplasia of the pituitary gland, transection of the stalk, empty sella syndrome or tumor in the central nervous system. 3. Pituitary volume and height appear to be of greatest diagnostic significance, while width (which varies little) can serve as an auxiliary parameter. (author)

  12. Nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Ethier, R.; Melanson, D.; Peters, T.M.

    1983-01-01

    Ten years following computerized tomography, a new technique called nuclear magnetic resonance revolutionizes the field of diagnostic imaging. A major advantage of nuclear magnetic resonance is that the danger of radiation is non-existent as compared to computerized tomography. When parts of the human body are subject to radio-frequencies while in a fixed magnetic field, its most detailed structures are revealed. The quality of images, the applications, as well as the indications are forever increasing. Images obtained at the level of the brain and spinal cord through nuclear magnetic resonance supercede those obtained through computerized tomography. Hence, it is most likely that myelography, along with pneumoencephalography will be eliminated as a diagnostic means. It is without a doubt that nuclear magnetic resonance is tomorrow's computerized tomography [fr

  13. Magnetic resonance imaging-a diagnostic tool for postoperative evaluation of dental implants: a case report.

    Science.gov (United States)

    Wanner, Laura; Ludwig, Ute; Hövener, Jan-Bernd; Nelson, Katja; Flügge, Tabea

    2018-04-01

    Compared with cone beam computed tomography (CBCT), magnetic resonance imaging (MRI) might be superior for the diagnosis of nerve lesions associated with implant placement. A patient presented with unilateral pain associated with dysesthesia in the region of the right lower lip and chin after implant placement. Conventional orthopantomography could not identify an association between the position of the inferior alveolar nerve and the implant. For 3-dimensional display of the implant in relation to the surrounding anatomy, CBCT was compared with MRI. MRI enabled the precise depiction of the implant position and its spatial relation to the inferior alveolar nerve, whereas the nerve position and its exact course within the mandible could not be directly displayed in CBCT. MRI may be a valuable, radiation-free diagnostic tool for the visualization of intraoral hard and soft tissues, offering an objective assessment of nerve injuries by a direct visualization of the inferior alveolar neurovascular bundle. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. How doctors generate diagnostic hypotheses: a study of radiological diagnosis with functional magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Marcio Melo

    Full Text Available In medical practice, diagnostic hypotheses are often made by physicians in the first moments of contact with patients; sometimes even before they report their symptoms. We propose that generation of diagnostic hypotheses in this context is the result of cognitive processes subserved by brain mechanisms that are similar to those involved in naming objects or concepts in everyday life.To test this proposal we developed an experimental paradigm with functional magnetic resonance imaging (fMRI using radiological diagnosis as a model. Twenty-five radiologists diagnosed lesions in chest X-ray images and named non-medical targets (animals embedded in chest X-ray images while being scanned in a fMRI session. Images were presented for 1.5 seconds; response times (RTs and the ensuing cortical activations were assessed. The mean response time for diagnosing lesions was 1.33 (SD ±0.14 seconds and 1.23 (SD ±0.13 seconds for naming animals. 72% of the radiologists reported cogitating differential diagnoses during trials (3.5 seconds. The overall pattern of cortical activations was remarkably similar for both types of targets. However, within the neural systems shared by both stimuli, activation was significantly greater in left inferior frontal sulcus and posterior cingulate cortex for lesions relative to animals.Generation of diagnostic hypotheses and differential diagnoses made through the immediate visual recognition of clinical signs can be a fast and automatic process. The co-localization of significant brain activation for lesions and animals suggests that generating diagnostic hypotheses for lesions and naming animals are served by the same neuronal systems. Nevertheless, diagnosing lesions was cognitively more demanding and associated with more activation in higher order cortical areas. These results support the hypothesis that medical diagnoses based on prompt visual recognition of clinical signs and naming in everyday life are supported by similar

  15. The diagnostic value of three sacroiliac joint pain provocation tests for sacroiliitis identified by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Arnbak, B; Jurik, A G; Jensen, R K

    2017-01-01

    OBJECTIVES: The aim of the current study was to investigate the diagnostic value of three sacroiliac (SI) joint pain provocation tests for sacroiliitis identified by magnetic resonance imaging (MRI) and stratified by gender. METHOD: Patients without clinical signs of nerve root compression were...

  16. Magnetic resonance annual 1986

    International Nuclear Information System (INIS)

    Kressel, H.Y.

    1986-01-01

    This book contains papers written on magnetic resonance during 1986. Topics include: musculosketetal magnetic resonance imaging; imaging of the spine; magnetic resonance chemical shift imaging; magnetic resonance imaging in the central nervous system; comparison to computed tomography; high resolution magnetic resonance imaging using surface coils; magnetic resonance imaging of the chest; magnetic resonance imaging of the breast; magnetic resonance imaging of the liver; magnetic resonance spectroscopy of neoplasms; blood flow effects in magnetic resonance imaging; and current and potential applications of clinical sodium magnetic resonance imaging

  17. Diagnostic accuracy of magnetic resonance imaging versus computed tomography in stress fractures of the lumbar spine

    International Nuclear Information System (INIS)

    Ganiyusufoglu, A.K.; Onat, L.; Karatoprak, O.; Enercan, M.; Hamzaoglu, A.

    2010-01-01

    Aim: To compare the diagnostic accuracy of magnetic resonance imaging (MRI) with computed tomography (CT) in stress fractures of the lumbar spine. Materials and methods: Radiological and clinical data from 57 adolescents and young adults with a diagnosis of stress injury of the lumbar spine were retrospectively reviewed. All cases had undergone both 1.5 T MRI and 16-section CT examinations. All MRI and CT images were retrospectively reviewed and evaluated in separate sessions. The fracture morphology (complete/incomplete, localization) and vertebral levels were noted at both the CT and MRI examinations. Bone marrow/peri-osseous soft-tissue oedema was also determined at MRI. Results: In total, 73 complete and 32 incomplete stress fractures were detected with CT. Sixty-seven complete, 24 incomplete fractures and eight stress reactions were detected using MRI in the same study group. Marrow oedema was also seen in eight of the complete and 20 of the incomplete fractures. The specificity, sensitivity, and accuracy of MRI in detecting fracture lines were 99.6, 86.7, and 97.2%, respectively. MRI was more accurate at the lower lumbar levels in comparison to upper lumbar levels. Conclusion: MRI has a similar diagnostic accuracy to CT in determining complete fractures with or without accompanying marrow oedema and incomplete fractures with accompanying marrow oedema, especially at the lower lumbar levels, which constitutes 94% of all fractures. At upper lumbar levels and in the incomplete fractures of the pars interarticularis with marked surrounding sclerosis, MRI has apparent limitations compared to CT imaging.

  18. Diagnostic accuracy of magnetic resonance imaging versus computed tomography in stress fractures of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Ganiyusufoglu, A.K., E-mail: kursady33@yahoo.co [Department of Radiology, Florence Nightingale Hospital, Istanbul (Turkey); Onat, L. [Department of Radiology, Florence Nightingale Hospital, Istanbul (Turkey); Karatoprak, O.; Enercan, M.; Hamzaoglu, A. [Department of Orthopedics and Traumatology, Florence Nightingale Hospital, Istanbul (Turkey)

    2010-11-15

    Aim: To compare the diagnostic accuracy of magnetic resonance imaging (MRI) with computed tomography (CT) in stress fractures of the lumbar spine. Materials and methods: Radiological and clinical data from 57 adolescents and young adults with a diagnosis of stress injury of the lumbar spine were retrospectively reviewed. All cases had undergone both 1.5 T MRI and 16-section CT examinations. All MRI and CT images were retrospectively reviewed and evaluated in separate sessions. The fracture morphology (complete/incomplete, localization) and vertebral levels were noted at both the CT and MRI examinations. Bone marrow/peri-osseous soft-tissue oedema was also determined at MRI. Results: In total, 73 complete and 32 incomplete stress fractures were detected with CT. Sixty-seven complete, 24 incomplete fractures and eight stress reactions were detected using MRI in the same study group. Marrow oedema was also seen in eight of the complete and 20 of the incomplete fractures. The specificity, sensitivity, and accuracy of MRI in detecting fracture lines were 99.6, 86.7, and 97.2%, respectively. MRI was more accurate at the lower lumbar levels in comparison to upper lumbar levels. Conclusion: MRI has a similar diagnostic accuracy to CT in determining complete fractures with or without accompanying marrow oedema and incomplete fractures with accompanying marrow oedema, especially at the lower lumbar levels, which constitutes 94% of all fractures. At upper lumbar levels and in the incomplete fractures of the pars interarticularis with marked surrounding sclerosis, MRI has apparent limitations compared to CT imaging.

  19. DIAGNOSTIC ACCURACY OF CLINICAL AND MAGNETIC RESONANCE IN KNEE MENISCI AND LIGAMENTOUS INJURIES

    Directory of Open Access Journals (Sweden)

    Nilesh

    2016-03-01

    Full Text Available OBJECTIVE The purpose of this study was to evaluate the reliability of clinical diagnosis compared to MRI findings in ligamentous and meniscal injuries with respect to arthroscopic confirmation as a gold standard. METHODS 485 patients with knee injuries were prospectively assessed by clinical evaluation and magnetic resonance imaging and correlated after therapeutic arthroscopy. The overall accuracy, clinically productive values of sensitivity and specificity was derived. The actual value of the test with respect to positive predictive and negative predictive value was also derived, taking arthroscopic findings as confirmatory. The overall partial and total agreement among the clinical, MRI and arthroscopy was documented. RESULTS The overall accuracy for clinical examination was 85, 92, 100 and 100 and accuracy for MRI was 90, 97, 97 and 97 for detecting medial meniscus, lateral meniscus, ACL and PCL tears respectively. Clinically lateral meniscus tears are difficult to diagnose clinically with negative predictive value (90 whereas ACL injuries do not need MRI for diagnosis as evident by a high negative predictive value (100 of clinical examination. Total agreement with the clinical findings confirmed by arthroscopy was 64.40% which was relatively high as compared to total agreement of MRI findings which was only 31.50%. We found similar total agreement versus total disagreement of both clinical and MRI to be only 2.74% indicating very high accuracy in clinical diagnosis of meniscal and ligamentous injuries combined. CONCLUSION The clinical evaluation alone is sufficient to diagnose meniscal and ACL/PCL pathologies and MRI should be considered only as a powerful negative diagnostic tool. The arthroscopy decision should not be heavily dependent on MRI for ligamentous injuries but reverse is true for meniscal lesions. MR evaluation functions as a powerful negative diagnostic tool to rule out doubtful and complex knee injuries.

  20. DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE ANGIOGRAPHY FOR UNRUPTURED CEREBRAL ANEURYSMS IN CORRELATION WITH DIGITAL SUBTRACTION ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Aleksandra Aracki-Trenkić

    2015-09-01

    Full Text Available Intracranial aneurysm is a focal, abnormal dilation of an artery of the brain. Magnetic resonance angiography (MRA is a non-invasive technique for vascular imaging and is thus widely used for screening for intracranial vascular lesions. The aim of the study was to show the diagnostic accuracy of 3D Time-of-Flight (3D TOF MRA in the detection of unruptured cerebral aneurysms with the use of digital subtraction angiography (DSA as the gold standard. A total of 2.612 consecutive patients underwent 3DTOF MRA. It showed unruptured aneurysms in 94 (3.6% patients. They included 68 women and 26 men ranging in age from 29 to 76 years (mean, 52.5 years. Twenty-six of them, 20 women and 6 men, underwent DSA. The Mann-Whitney U test was used for the correlation of size. Fisher’s test was used for the correlation of location. The statistical level of significance was set at p0.05 of aneurysms between TOF MRA and DSA. MRA is an accurate and non-invasive method for diagnosis of unruptured intracranial aneurysms. The results of study show the compatibility of MRA findings, the location and the size of an aneurysm in comparison with the “gold standard” – cerebral DSA.

  1. Diagnostic assessment of the heart after infarction: what is the role of magnetic resonance imaging?

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Taupitz, M.; Hamm, B.

    1999-01-01

    There have been considerable advances in the diagnostic assessment of the heart by magnetic resonance imaging (MRI) in recent years. Thus, MRI as a one-stop shop modality for the comprehensive noninvasive evaluation of coronary heart disease and myocardial infarction may soon become a reality. This article presents an overview of the present possibilities and future potential of evaluating myocardial anatomy, function, perfusion, and coronary anatomy after myocardial infarction. Cine MRI provides a reliable analysis of regional and global disturbances of cardiac wall motion with a high temporal and spatial resolution. Tagging techniques permit the noninvasive labelling of parts of the myocardium and the identification of three-dimensional patterns of contraction. Myocardial perfusion and disturbed wall motion under pharmacologic stress can be reliably assessed by MRI as well. What is unique is the visualization of myocardial edema, which is made possible by the high soft-tissue contrast resolution. The as yet limited potential to assess coronary arteries and coronary bypasses is likewise discussed. (orig.) [de

  2. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  3. Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Robert H. Morris

    2014-11-01

    Full Text Available Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medical point of care diagnostics. This great diversity is seeing exciting developments in magnetic resonance sensing technology published in application specific journals where they are often not seen by the wider sensor community. It is clear that there is enormous interest in magnetic resonance sensors which represents a significant growth area. The aim of this special edition of Sensors was to address the wide distribution of relevant articles by providing a forum to disseminate cutting edge research in this field in a single open source publication.[...

  4. Nitroxide radicals as contrast substances for magnetic resonance imaging diagnostics. Part 1

    International Nuclear Information System (INIS)

    Zhelev, Z.

    2016-01-01

    In last ten years, there is a significant progress in the selective and localized detection of redox-active compounds in the cells, tissues, and intact organisms. This progress is due to the development of new synthetic and genetically encoded redox-sensitive contrast substances, as well as due to the improvement of the techniques for their imaging: fluorescent, chemiluminescent, magnetic resonance, nuclear, ultrasonic. One of the most attractive redox-sensitive contrast substances are cyclic (stable) nitroxide radicals. They can be visualized and analyzed in vitro and in vivo by a variety of magnetic resonance techniques - electron-paramagnetic resonance imaging (EPRI), magnetic resonance imaging (MRI), Overhauser-enhanced MRI (OMRI). This review describes the merits and demerits of the nitroxide-enhanced EPR and MRI and the perspectives for their application in biomedical studies and clinical practice. The article is intended for a wide range of readers - from students to specialists in the field. Key words: Magnetic Resonance Imaging (MRI). Electron-Paramagnetic Resonance (EPR). Overhauser-Enhanced MRI (O MRI). Nitroxide

  5. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn?s Disease

    OpenAIRE

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-01-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn?s disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were p...

  6. Magnetic resonance imaging and magnetic resonance arthrography of the shoulder: dependence on the level of training of the performing radiologist for diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Theodoropoulos, John S. [University of Toronto, Division of Orthopaedics, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); Andreisek, Gustav [University of Toronto, Department of Medical Imaging, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); University Hospital Zuerich, Institute for Diagnostic Radiology, Zuerich (Switzerland); Harvey, Edward J. [McGill University, Division of Orthopaedics, MUHC - Montreal General Hospital, Montreal, Quebec (Canada); Wolin, Preston [Center for Athletic Medicine, Chicago, IL (United States)

    2010-07-15

    Discrepancies were identified between magnetic resonance (MR) imaging and clinical findings in patients who had MR imaging examinations evaluated by community-based general radiologists. The purpose of this study was to evaluate the diagnostic performance of MR imaging examinations of the shoulder with regard to the training level of the performing radiologist. A review of patient charts identified 238 patients (male/female, 175/63; mean age, 40.4 years) in whom 250 arthroscopies were performed and who underwent MR imaging or direct MR arthrography in either a community-based or hospital-based institution prior to surgery. All MR imaging and surgical reports were reviewed and the diagnostic performance for the detection of labral, rotator cuff, biceps, and Hill-Sachs lesions was determined. Kappa and Student's t test analyses were performed in a subset of cases in which initial community-based MR images were re-evaluated by hospital-based musculoskeletal radiologists, to determine the interobserver agreement and any differences in image interpretation. The diagnostic performance of community-based general radiologists was lower than that of hospital-based sub-specialized musculoskeletal radiologists. A sub-analysis of re-evaluated cases showed that musculoskeletal radiologists performed better. {kappa} values were 0.208, 0.396, 0.376, and 0.788 for labral, rotator cuff, biceps, and Hill-Sachs lesions (t test statistics: p =<0.001, 0.004, 0.019, and 0.235). Our results indicate that the diagnostic performance of MR imaging and MR arthrography of the shoulder depends on the training level of the performing radiologist, with sub-specialized musculoskeletal radiologists having a better diagnostic performance than general radiologists. (orig.)

  7. Diagnostic Accuracy of Dynamic Contrast Enhanced Magnetic Resonance Imaging in Characterizing Lung Masses

    Science.gov (United States)

    Inan, Nagihan; Arslan, Arzu; Donmez, Muhammed; Sarisoy, Hasan Tahsin

    2016-01-01

    Background Imaging plays a critical role not only in the detection, but also in the characterization of lung masses as benign or malignant. Objectives To determine the diagnostic accuracy of dynamic magnetic resonance imaging (MRI) in the differential diagnosis of benign and malignant lung masses. Patients and Methods Ninety-four masses were included in this prospective study. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, followed by a T1-weighted FFE sequence in the late phase (5th minutes). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained and the maximum relative enhancement, wash-in rate, and time-to-peak enhancement of masses in both groups were calculated. Results The early phase contrast enhancement patterns were homogeneous in 78.2% of the benign masses, while heterogeneous in 74.4% of the malignant tumors. On the late phase images, 70.8% of the benign masses showed homogeneous enhancement, while most of the malignant masses showed heterogeneous enhancement (82.4%). During the first pass, the maximum relative enhancement and wash-in rate values of malignant masses were significantly higher than those of the benign masses (P = 0.03 and 0.04, respectively). The cutoff value at 15% yielded a sensitivity of 85.4%, specificity of 61.2%, and positive predictive value of 68.7% for the maximum relative enhancement. Conclusion Contrast enhancement patterns and SI-time curve analysis of MRI are helpful in the differential diagnosis of benign and malignant lung masses. PMID:27703654

  8. Diagnostic Performance of a Rapid Magnetic Resonance Imaging Method of Measuring Hepatic Steatosis

    Science.gov (United States)

    House, Michael J.; Gan, Eng K.; Adams, Leon A.; Ayonrinde, Oyekoya T.; Bangma, Sander J.; Bhathal, Prithi S.; Olynyk, John K.; St. Pierre, Tim G.

    2013-01-01

    Objectives Hepatic steatosis is associated with an increased risk of developing serious liver disease and other clinical sequelae of the metabolic syndrome. However, visual estimates of steatosis from histological sections of biopsy samples are subjective and reliant on an invasive procedure with associated risks. The aim of this study was to test the ability of a rapid, routinely available, magnetic resonance imaging (MRI) method to diagnose clinically relevant grades of hepatic steatosis in a cohort of patients with diverse liver diseases. Materials and Methods Fifty-nine patients with a range of liver diseases underwent liver biopsy and MRI. Hepatic steatosis was quantified firstly using an opposed-phase, in-phase gradient echo, single breath-hold MRI methodology and secondly, using liver biopsy with visual estimation by a histopathologist and by computer-assisted morphometric image analysis. The area under the receiver operating characteristic (ROC) curve was used to assess the diagnostic performance of the MRI method against the biopsy observations. Results The MRI approach had high sensitivity and specificity at all hepatic steatosis thresholds. Areas under ROC curves were 0.962, 0.993, and 0.972 at thresholds of 5%, 33%, and 66% liver fat, respectively. MRI measurements were strongly associated with visual (r2 = 0.83) and computer-assisted morphometric (r2 = 0.84) estimates of hepatic steatosis from histological specimens. Conclusions This MRI approach, using a conventional, rapid, gradient echo method, has high sensitivity and specificity for diagnosing liver fat at all grades of steatosis in a cohort with a range of liver diseases. PMID:23555650

  9. Magnetic resonance in the diagnostic imaging study of mesial temporal sclerosis

    International Nuclear Information System (INIS)

    Pastor, E.; Sanchez, J. C.; Rodriguez, I.; Altuzarra, A.; Machado, F.; Aguilar, D.

    2001-01-01

    Mesial temporal sclerosis (MTS) consists of hippocampal atrophy and gliosis and is the most common cause of temporal lobe epilepsy. The objective of the authors was to establish a magnetic resonance imaging (MRI) protocol for its diagnosis. A prospective study was carried out in 72 patients with drug resistant complex partial seizures (42 women and 30 men ranging in age from 6 to 66 year: mean: 30 years). Using a 1.5-Tesla magnet, paracoronal sections were made in hippocampi for T1-weighted inversion-recovery images and volume measurements, fluid-attenuated inversion-recovery (FLAIR) and T2 relaxometry. A control group of 30 health volunteers was included in the study. MTS was considered to be indicated by the presence of atrophy and hyperintensity in hippocampi on T2-weighted images. There were no differences among the hippocampi of the healthy individuals. The confidence intervals (mean± 1.96 SD) were 4169 mm''3-5911 mm''3 for volume of right side, 4097 mm''3-5940 mm''3 for volume of left side and 98-113 ms for T2 relaxation time. MTS was detected in 40 patients (55.5%): 23 cases involving the left side, 13 involving the right and 4 cases of bilateral asymmetric involvement. The 95% confidence intervals for the diagnostic validity of the results (sensitivity/specificity) were (88.8%-97.2%)/(87.6%-96.4%) for T1 volumetry, (88.8%-97.2%)(95.7%-100.3%) for FLAIR and (85.4%-96.6%)/(85.4%-96.6%) for T2 relaxometry. In 5 cases of MTS, astrophy of other extra hippocampal structures was also observed, and MTS was associated with an extra hippocampal lesion (dual pathology), especially neurona migration disorders, in 8 patients. Seventeen patients (23.5%) presented lesions without MTS (tumors, cortical dysplasias and heterotopias) and there was no MRI evidence of anomalies in 15 (21%). Twenty-five patients underwent surgical treatment: 20 with MTS (19 diagnosed according to MRI and one in whom there had been no abnormal findings), 4 with tumors and 1 with a ballooned cell

  10. Magnetic resonance cholangiopancreaticography as a diagnostic tool for common bile duct stones - A comparison with ERCP and clinical follow-up

    NARCIS (Netherlands)

    Kats, J; Kraai, M; Dijkstra, AJ; Koster, K; ter Borg, F; Hazenberg, HJA; Schattenkerk, ME; des Plantes, BGZ; Eddes, EH

    2003-01-01

    Background/Aims: The diagnostic potential of magnetic resonance cholangiopancreaticography (MRCP) has improved as a result of evolving technique. MRCP has the advantage of negligible morbidity and mortality in contrast to endoscopic retrograde cholangiopancreatography (ERCP). This study was

  11. The diagnostic accuracy of 1.5T magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries.

    Science.gov (United States)

    Wade, Ryckie G; Itte, Vinay; Rankine, James J; Ridgway, John P; Bourke, Grainne

    2018-03-01

    Identification of root avulsions is of critical importance in traumatic brachial plexus injuries because it alters the reconstruction and prognosis. Pre-operative magnetic resonance imaging is gaining popularity, but there is limited and conflicting data on its diagnostic accuracy for root avulsion. This cohort study describes consecutive patients requiring brachial plexus exploration following trauma between 2008 and 2016. The index test was magnetic resonance imaging at 1.5 Tesla and the reference test was operative exploration of the supraclavicular plexus. Complete data from 29 males was available. The diagnostic accuracy of magnetic resonance imaging for root avulsion(s) of C5-T1 was 79%. The diagnostic accuracy of a pseudomeningocoele as a surrogate marker of root avulsion(s) of C5-T1 was 68%. We conclude that pseudomeningocoles were not a reliable sign of root avulsion and magnetic resonance imaging has modest diagnostic accuracy for root avulsions in the context of adult traumatic brachial plexus injuries. III.

  12. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  13. Magnetic resonance metabolomics of intact tissue: a biotechnological tool in cancer diagnostics and treatment evaluation.

    Science.gov (United States)

    Bathen, Tone F; Sitter, Beathe; Sjøbakk, Torill E; Tessem, May-Britt; Gribbestad, Ingrid S

    2010-09-01

    Personalized medicine is increasingly important in cancer treatment for its role in staging and its potential to improve stratification of patients. Different types of molecules, genes, proteins, and metabolites are being extensively explored as potential biomarkers. This review discusses the major findings and potential of tissue metabolites determined by high-resolution magic angle spinning magnetic resonance spectroscopy for cancer detection, characterization, and treatment monitoring.

  14. Additional diagnostic value of systolic dysfunction induced by dipyridamole stress cardiac magnetic resonance used in detecting coronary artery disease.

    Science.gov (United States)

    Husser, Oliver; Bodí, Vicente; Sanchís, Juan; Mainar, Luis; Núñez, Julio; López-Lereu, María P; Monmeneu, José V; Ruiz, Vicente; Rumiz, Eva; Moratal, David; Chorro, Francisco J; Llácer, Angel

    2009-04-01

    Dipyridamole stress perfusion cardiovascular magnetic resonance (CMR) is used to detect coronary artery disease (CAD). However, few data are available on the diagnostic value of the systolic dysfunction induced by dipyridamole. This study investigated whether the induction of systolic dysfunction supplements the diagnostic information provided by perfusion imaging in the detection of CAD. Overall, 166 patients underwent dipyridamole CMR and quantitative coronary angiography, with CAD being defined as a stenosis > or =70%. Systolic dysfunction at rest, systolic dysfunction with dipyridamole, induced systolic dysfunction, and stress first-pass perfussion deficit (PD) and delayed enhancement were quantified. In the multivariate analysis, PD (hazard ratio [HR]=1.6; 95% confidence interval [CI], 1.33-1.91;Pstatistic for predicting CAD (0.81 vs. 0.87; P=.02). Combining induced systolic dysfunction with perfusion imaging increases the diagnostic accuracy of detecting CAD and enables patients with severe ischemia and a high probability of CAD to be identified.

  15. Ultra-Wideband Sensors for Improved Magnetic Resonance Imaging, Cardiovascular Monitoring and Tumour Diagnostics

    Directory of Open Access Journals (Sweden)

    Frank Seifert

    2010-12-01

    Full Text Available The specific advantages of ultra-wideband electromagnetic remote sensing (UWB radar make it a particularly attractive technique for biomedical applications. We partially review our activities in utilizing this novel approach for the benefit of high and ultra-high field magnetic resonance imaging (MRI and other applications, e.g., for intensive care medicine and biomedical research. We could show that our approach is beneficial for applications like motion tracking for high resolution brain imaging due to the non-contact acquisition of involuntary head motions with high spatial resolution, navigation for cardiac MRI due to our interpretation of the detected physiological mechanical contraction of the heart muscle and for MR safety, since we have investigated the influence of high static magnetic fields on myocardial mechanics. From our findings we could conclude, that UWB radar can serve as a navigator technique for high and ultra-high field magnetic resonance imaging and can be beneficial preserving the high resolution capability of this imaging modality. Furthermore it can potentially be used to support standard ECG analysis by complementary information where sole ECG analysis fails. Further analytical investigations have proven the feasibility of this method for intracranial displacements detection and the rendition of a tumour’s contrast agent based perfusion dynamic. Beside these analytical approaches we have carried out FDTD simulations of a complex arrangement mimicking the illumination of a human torso model incorporating the geometry of the antennas applied.

  16. Ultra-wideband sensors for improved magnetic resonance imaging, cardiovascular monitoring and tumour diagnostics.

    Science.gov (United States)

    Thiel, Florian; Kosch, Olaf; Seifert, Frank

    2010-01-01

    The specific advantages of ultra-wideband electromagnetic remote sensing (UWB radar) make it a particularly attractive technique for biomedical applications. We partially review our activities in utilizing this novel approach for the benefit of high and ultra-high field magnetic resonance imaging (MRI) and other applications, e.g., for intensive care medicine and biomedical research. We could show that our approach is beneficial for applications like motion tracking for high resolution brain imaging due to the non-contact acquisition of involuntary head motions with high spatial resolution, navigation for cardiac MRI due to our interpretation of the detected physiological mechanical contraction of the heart muscle and for MR safety, since we have investigated the influence of high static magnetic fields on myocardial mechanics. From our findings we could conclude, that UWB radar can serve as a navigator technique for high and ultra-high field magnetic resonance imaging and can be beneficial preserving the high resolution capability of this imaging modality. Furthermore it can potentially be used to support standard ECG analysis by complementary information where sole ECG analysis fails. Further analytical investigations have proven the feasibility of this method for intracranial displacements detection and the rendition of a tumour's contrast agent based perfusion dynamic. Beside these analytical approaches we have carried out FDTD simulations of a complex arrangement mimicking the illumination of a human torso model incorporating the geometry of the antennas applied.

  17. Prostate cancer in magnetic resonance imaging: diagnostic utilites of spectroscopic sequences

    International Nuclear Information System (INIS)

    Caivano, Rocchina; Cirillo, Patrizia; Lotumolo, Antonella; Fortunato, Giovanna; Zandolino, Alexis; Cammarota, Aldo; Balestra, Antonio; Macarini, Luca; Vita, Giulia

    2012-01-01

    The aim of our work is to determine the efficacy of a combined study 3 Tesla Magnetic Resonance Imaging (3T MRI), with phased-array coil, for the detection of prostate cancer using magnetic resonance spectroscopy (MRS) and diffusion-weighted images (DWI) in identifying doubt nodules. In this study, we prospectively studied 46 patients who consecutively underwent digital-rectal exploration for high doses of prostate specific antigen (PSA), as well as a MRI examination and a subsequent rectal biopsy. The study of magnetic resonance imaging was performed with a Philips Achieva 3T scanner and phased-array coil. The images were obtained with turbo spin-echo sequences T2-weighted images, T1-weighted before and after the administration of contrast medium, DWI sequences and 3D spectroscopic sequences. The ultrasound-guided prostate biopsy was performed approximately 15 days after the MRI. The data obtained from MR images and spectroscopy were correlated with histological data. MRI revealed sensitivity and specificity of 88% and 61% respectively and positive predictive value (PPV) of 73%, negative predicted value (NPV) of 81% and accuracy of 76%. In identifying the location of prostate cancer, the sensitivity of 3T MRS was 92%, with a specificity of 89%, PPV of 87%, NPV of 88% and accuracy of 87%; DWI showed a sensitivity of 88%, specificity of 61%, PPV of 73%, NPV of 81% and accuracy of 76%. The 3T MR study with phased-array coil and the use of DWI and spectroscopic sequences, in addition to T2-weighted sequences, revealed to be accurate in the diagnosis of prostate cancer and in the identification of nodules to be biopsied. It may be indicated as a resolute way before biopsy in patients with elevated PSA value and can be proposed in the staging and follow-up.

  18. Shoulder impingement syndrome: diagnostic accuracy of magnetic resonance imaging and radiographic signs

    International Nuclear Information System (INIS)

    Williamson, M.P.; Chandnani, V.P.; Baird, D.E.; Deberardino, T.M.; Swenson, G.W.; Hansen, M.F.

    1994-01-01

    Shoulder impingement syndrome is commonly encountered in orthopaedics. In a blinded retrospective study, magnetic resonance imaging and roentgenographic signs in 41 patients with clinical signs of impingement syndrome were compared with 40 control patients. Statistically significant differences between the groups included the absence of subacromial fat, as well as the presence of a supraspinatus tear, subacromial osteophytes, and a decreased coracohumeral distance. Other signs reported to occur in patients with impingement syndrome did not vary significantly in the population studied. 20 refs., 12 figs

  19. Magnetic resonance imaging for diagnostic evaluation of hernia of an invertebral disk

    International Nuclear Information System (INIS)

    Beyer, H.K.; Oppel, G.; Bluemm, R.; Uhlenbrock, D.

    1988-01-01

    The article reports experience gained within three years with diagnostic NMR imaging of the lumbar spine. On the basis of results obtained by almost 500 examinations, an optimisation concept with regard to measuring sequences and orientation of sectional cuts is presented. Imaging of the spine in three planes, with sectional layer thickness between 3 and 5 mm, using a 1.5 Tesla system, seems to yield the diagnostic optimum, and in our opinion is superior over invasive myelography and CT scanning. A prospective study we made indicates a hit rate of 97.2%, and of 100% for evaluation of the results obtained with the 1.5 Tesla system together with an evaluation of the paraxial sections. The magnetic field intensity of 1.5 Tesla especially improves the quality of images of paraxial cuts as compared with the 0.5 Tesla field system, due to the better contrast-to-noise ratio, and thinner sections. (orig.) [de

  20. The diagnostic value of dynamic magnetic resonance urography in children with urinary tract infection

    Directory of Open Access Journals (Sweden)

    Zarabi V

    2011-05-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Urinary tract infection 0 in children causes renal scarring and permanent damage to the organ. In this study, we compared the diagnostic value of magnetic resonance urogram for urinary tract anomalies with other conventional imaging methods in children with UTI. "n"nMethods : In this case-control study, 190 children (mean age 3.23±3.59 yrs with UTI were recruited from the Pediatric Ward of Rasul-e-Akram Hospital during 2007-2009. The patients were divided into two groups based on the applied imaging technique: MRU (cases and conventional imaging groups (controls."n"nResults : Abnormal imaging detection rates for Ultrasonography were 32%, X-ray of kidneys, ureters and bladder (KUB 9%, Intravenous Pyelogram (IVP 26%, Voiding Cystoure therogram (VCUG 54%, Dimercaptosuccinic Acid scan (DMSA indicating non-obstructive (reflux uropathy in 76% (mean age 3.5 yrs and MRU 43% (mean age 1.6 yrs, respectively. A meaningful correlation was observed between MRU and DMSA scan with IVP results (Kappa=0.75. KUB and Ultrasonography had similar results in cases with abnormal MRU and DMSA scan (P=0.121. MRU had strong agreement with VCUG and IVP for the detection of obstructive uropathy and scar due to congenital malformation

  1. Magnetic resonance instrumentation

    International Nuclear Information System (INIS)

    Bell, R.A.

    1987-01-01

    Magnetic resonance (MR), while opening new vistas to diagnostic medicine, utilizes equipment that is unfamiliar to most clinicians. Beyond learning to cope with new terms, such as spin-echo, T1, T2, and spin density, health care professionals are faced with the inclusion of magnetic and radiofrequency effects in their facilities produced by a complex array of devices. It is the purpose of this chapter to outline the components of an MR imaging system, to discuss their functions, and to note the variations in equipment commercially available

  2. Positivity of magnetic resonance imaging the GIROIMAG-01: Diagnostic tools in injuries of the central nervous system

    International Nuclear Information System (INIS)

    Noda Guerra, Manuel Ernesto; Corujo Torres, Pedro A.; Gonzalez Ferro, Idalia; Daudinot Gomez, Barbara; Montoya Pedron, Arquimedes

    2001-01-01

    A study was made to compare the positivity of magnetic resonance imaging with that of other imaging and neuropsychological diagnostic tools in injuries of the central nervous system in order to determine the sensitivity, specificity, strength and the test error with the GIROIMAG-01 Cuban tomograph in the diagnostic of these injuries. An intentional sample of 398 patients was selected. Only those patients who had undergone computed axial tomography, electroencephalogram or evoked multimodal potentials or both, whose results were registered in the study requests, could be selected. The most representative injuries among the diagnoses made were the degenerative diseases, the brain and cerebellar tumors, the cerebrovascular accidents, the demyelinizating diseases and hydrocephalous. It was demonstrated that this tomograph has an elevated sensitivity and specificity for the detection of injuries of the central nervous system

  3. Diagnostic Accuracy of Diffusion Weighted Magnetic Resonance Imaging in the Detection of Myometrial Invasion in Endometrial Carcinoma

    International Nuclear Information System (INIS)

    Masroor, I.; Hussain, Z.; Taufiq, M.

    2016-01-01

    Objective: To determine the diagnostic accuracy of Diffusion-Weighted Magnetic Resonance Imaging (DWMRI) in the detection of myometrial invasion in endometrial cancer taking histopathology as gold standard. Study Design: Cross-sectional validation study. Place and Duration of Study: Department of Radiology, The Aga Khan University Hospital, Karachi, from January to December 2012. Methodology: DWMRI (b-value = 50,400 and 800 s/mm2) was performed in 85 patients of biopsy-proven endometrial carcinoma before hysterectomy using body and spine coil at 1.5 Tesla. DWI was evaluated for presence of myometrial invasion by tumor with histopathology as gold standard. Sensitivity, specificity, the negative predictive value and positive predictive value and accuracy of DWI were assessed against the gold standard. Results: On DWI, superficial myometrial invasion was found in 42 patients and deep myometrial invasion in 43. On histopathology, superficial myometrial invasion was found in 53 patients and deep myometrial invasion in 32. Hence sensitivity, specificity, positive predictive value, negative predictive value and accuracy for the assessment of myometrial invasion by endometrial tumor on DW images was 90 percentage, 73 percentage, 67 percentage, 92 percentage and 80 percentage, respectively. Diagnostic accuracy of diffusion-weighted magnetic resonance imaging in detection of myometrial invasion in endometrial cancer was 80 percentage. Conclusion: DWI is highly accurate in assessing myometrial invasion and can be used as an adjunct to routine MRI for pre-operative evaluation of myometrial invasion of endometrial cancer. (author)

  4. Magnetic resonance fingerprinting.

    Science.gov (United States)

    Ma, Dan; Gulani, Vikas; Seiberlich, Nicole; Liu, Kecheng; Sunshine, Jeffrey L; Duerk, Jeffrey L; Griswold, Mark A

    2013-03-14

    Magnetic resonance is an exceptionally powerful and versatile measurement technique. The basic structure of a magnetic resonance experiment has remained largely unchanged for almost 50 years, being mainly restricted to the qualitative probing of only a limited set of the properties that can in principle be accessed by this technique. Here we introduce an approach to data acquisition, post-processing and visualization--which we term 'magnetic resonance fingerprinting' (MRF)--that permits the simultaneous non-invasive quantification of multiple important properties of a material or tissue. MRF thus provides an alternative way to quantitatively detect and analyse complex changes that can represent physical alterations of a substance or early indicators of disease. MRF can also be used to identify the presence of a specific target material or tissue, which will increase the sensitivity, specificity and speed of a magnetic resonance study, and potentially lead to new diagnostic testing methodologies. When paired with an appropriate pattern-recognition algorithm, MRF inherently suppresses measurement errors and can thus improve measurement accuracy.

  5. Diagnostic role of magnetic resonance angiography in Swyer James syndrome: Case series of two cases

    Directory of Open Access Journals (Sweden)

    Parashari Umesh

    2010-01-01

    Full Text Available Swyer James syndrome is a rare syndrome which occurs due to viral illness in early childhood. The post infective obliterative bronchiolitis results in arrest of lung growth and alveolarization with reduced vascularity resulting in classical radiological features. We describe two cases of patients fulfilling all the criteria of the syndrome - 1 Unilateral hyperlucent small lung in chest radiograph with air trapping on expiration, small ipsilateral hila and pulmonary artery. 2 Diffuse decrease in attenuation of lung parenchyma with bronchiectasis and reduction in vascularity. 3 Unilateral pruned tree appearance on angiography (MRA. The clinical presentation was recurrent chest infection in a child and infrequent bouts of hemoptysis in a middle aged female. The study demonstrates the role of magnetic resonance angiography in diagnosing the condition.

  6. Role of 3.0 Tesla magnetic resonance hysterosalpingography in the diagnostic work-up of female infertility.

    Science.gov (United States)

    Cipolla, Valentina; Guerrieri, Daniele; Pietrangeli, Daniela; Santucci, Domiziana; Argirò, Renato; de Felice, Carlo

    2016-09-01

    Imaging evaluation plays a crucial role in the diagnostic work-up of female infertility. In recent years, the possibility to evaluate tubal patency using 1.5 Tesla magnetic resonance (1.5T MR) has been studied. To assess the feasibility of 3.0 Tesla magnetic resonance (3.0T MR) hysterosalpingography and its role in the diagnostic work-up of female infertility and to evaluate if this fast "one-stop-shop" imaging approach should be proposed as a first-line examination. A total of 116 infertile women were enrolled in this prospective study; all underwent 3.0T MR hysterosalpingography. After standard imaging of the pelvis, tubal patency was assessed by acquiring 3D dynamic time-resolved T1-weighted (T1W) sequences during manual injection of 4-5 mL of contrast solution consisting of gadolinium and normal sterile saline. Images were evaluated by two radiologists with different experience in MR imaging (MRI). The examination was successfully completed in 96.5% of cases, failure rate was 3.5%. Dynamic sequences showed bilateral tubal patency in 64.3%, unilateral tubal patency in 25.9%, and bilateral tubal occlusion in 9.8%. Extratubal abnormalities were found in 69.9% of patients. Comprehensive analysis of morphological and dynamic sequences showed extratubal abnormalities in 43.1% of patients with bilateral tubal patency. 3.0T MR hysterosalpingography is a feasible, simple, fast, safe, and well-tolerated examination, which allows evaluation of tubal patency and other pelvic causes of female infertility in a single session, and it may thus represent a "one-stop-shop" solution in female infertility diagnostic work-up. © The Foundation Acta Radiologica 2015.

  7. Diagnostic sensitivity of radiography, ultrasonography, and magnetic resonance imaging for detecting shoulder osteochondrosis/osteochondritis dissecans in dogs.

    Science.gov (United States)

    Wall, Corey R; Cook, Cristi R; Cook, James L

    2015-01-01

    Radiography, magnetic resonance imaging (MRI), and ultrasonography are commonly used for diagnosis of shoulder osteochondrosis and osteochondritis dissecans (OC/OCD) in dogs, however there is a lack of published information on the relative diagnostic sensitivities of these modalities. The purpose of this prospective study was to compare diagnostic sensitivities of these modalities for detecting shoulder OC/OCD in a group of dogs, using arthroscopy as the reference standard. Inclusion criteria were history and clinical findings consistent with osteochondrosis and/or osteochondritis dissecans involving at least one shoulder. With informed client consent, both shoulders for all included dogs were examined using standardized radiography, ultrasonography, MRI, and arthroscopy protocols. One of three veterinary surgeons recorded clinical and arthroscopic findings without knowledge of diagnostic imaging findings. One of two veterinary radiologists recorded diagnostic imaging findings without knowledge of clinical and arthroscopic findings. Eighteen client-owned dogs (n = 36 shoulders) met inclusion criteria. Diagnostic sensitivity, specificity, and accuracy (correct classification rate) values for detecting presence or absence of shoulder osteochondrosis/osteochondritis dissecans were as follows: radiography (88.5%, 90%, 88.9%), ultrasonography (92%, 60%, 82.6%), and MRI (96%, 88.9%, 94.4%). Odds of a correct diagnosis for MRI were 3.2 times more than ultrasonography and two times more than radiography. For MRI detection of lesions, the sagittal T2 or PD-FAT SAT sequences were considered to be most helpful. For radiographic detection of lesions, the additional supinated-mediolateral and pronated-mediolateral projections were considered to be most helpful. Findings from the current study support more evidence-based diagnostic imaging recommendations for dogs with clinically suspected shoulder osteochondrosis or osteochondritis dissecans. © 2014 American College of

  8. Diagnostic evaluation of ischemic heart disease by X-ray computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Masuda, Yoshiaki; Kobayashi, Shiro; Takasu, Junichiro; Sakakibara, Makoto; Imai, Hitoshi; Aoyagi, Yutaka; Morooka, Nobuhiro; Watanabe, Shigeru; Inagaki, Yoshiaki

    1987-01-01

    To assess the usefulness of X-ray computed tomography (CT) and magnetic resonance imaging (MRI) in detecting and evaluating ischemic heart disease, conventional and enhanced CT were performed for 180 patients (150 with transmural infarction, 12 with subendocardial infarction, and 18 with angina pectoris). MRI examinations were performed for 38 patients (31 with transmural infarction, three with subendocardial infarction, and four with angina pectoris). With enhanced CT, two findings in the myocardium were direct evidence of myocardial infarction: 1) filling defects on the early scans, and 2) late enhancement of the myocardium on the delayed scans. The former were observed mainly at the sites of recent anterior myocardial infarction and the latter were seen in about half of the patients with recent and remote anterior myocardial infarctions. However, these findings were inadequately imaged in patients with inferoposterior infarction and subendocardial infarction. Among 137 patients with transmural infarction, enhanced CT revealed left ventricular aneurysms in 51 (37 %) and ventricular thrombi in 26 (19 %). ECG-gated MRI apparatus having a superconducting magnetic operating at 0.25 Tesla was used, and data for this study were collected using the single-slice spin echo technique. In eight of nine patients with acute myocardial infarction, gated MRI demonstrated the infarcted myocardium as regions of high signal intensity relative to that of the adjacent normal myocardium. Such a difference in MRI signal intensity was scarcely recognized in the chronic stage of myocardial infarction, but the indirect findings of infarction, such as regional wall thinning, wall motion disturbances, left ventricular aneurysms, and ventricular thrombi were easily detected using MRI. No characteristic finding was obtained by CT or MRI in patients with angina pectoris. (author)

  9. The Use of Cardiac Magnetic Resonance Imaging in the Diagnostic Workup and Treatment of Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Peter Haemers

    2012-01-01

    Full Text Available Atrial fibrillation (AF is the most common cardiac arrhythmia and imposes a huge clinical and economic burden. AF is correlated with an increased morbidity and mortality, mainly due to stroke and heart failure. Cardiovascular imaging modalities, including echocardiography, computed tomography (CT, and cardiovascular magnetic resonance (CMR, play a central role in the workup and treatment of AF. One of the major advantages of CMR is the high contrast to noise ratio combined with good spatial and temporal resolution, without any radiation burden. This allows a detailed assessment of the structure and function of the left atrium (LA. Of particular interest is the ability to visualize the extent of LA wall injury. We provide a focused review of the value of CMR in identifying the underlying pathophysiological mechanisms of AF, its role in stroke prevention and in the guidance of radiofrequency catheter ablation. CMR is a promising technique that could add valuable information for therapeutic decision making in specific subpopulations with AF.

  10. The diagnostic value of magnetic resonance urography using a balanced turbo field echo sequence

    Energy Technology Data Exchange (ETDEWEB)

    Cifci, Egemen; Coban, Goekcen [Baskent University Faculty of Medicine, Department of Radiology, Konya (Turkey); Cicek, Tufan; Goenuelalan, Umut [Baskent University Faculty of Medicine, Department of Urology, Konya (Turkey)

    2016-12-15

    The aim of the study was to compare the inter-observer variability and the accuracy of magnetic resonance urography (MRU) using a thin sectional balanced-turbo field echo (B-TFE) sequence for detecting ureteral calculi and to determine the effect of additional factors (size, density and location of the calculus) on the sensitivity and specificity of the MRU. MRU and CT images were evaluated independently by two radiologists according to presence, density and localization of calculi. The degrees of inter-rater agreement for categorical items were evaluated by the Kappa coefficient. According to the 1st and 2nd observers, the sensitivity of MRU was 65.9 %, 71.8 % and the specificity of MRU was 95.9 %, 100 %, respectively. Inter-observer agreement was 84.6 % for stone detection. The larger size had a better effect on detectability (p < 0.05). Also, the higher density had a better impact on detectability (p < 0.05). Our study has shown that B-TFE MRU was useful to detect ureteral calculi. However, B-TFE MRU has low sensitivity and high specificity in comparison with CT images. MRU is a reasonable alternative imaging technique for follow-up periods of selective groups like patients with large urinary stones, children or pregnant patients when ionizing radiation is undesirable. (orig.)

  11. Ectopic Molar Pregnancy: Diagnostic Efficacy of Magnetic Resonance Imaging and Review of the Literature.

    Science.gov (United States)

    Yamada, Yasushi; Ohira, Satoshi; Yamazaki, Teruyuki; Shiozawa, Tanri

    2016-01-01

    Ectopic molar pregnancy is extremely rare, and preoperative diagnosis is difficult. Our literature search found only one report of molar pregnancy diagnosed preoperatively. Moreover, there is no English literature depicting magnetic resonance image (MRI) findings of ectopic molar pregnancy. We report a case of ectopic molar pregnancy preoperatively diagnosed using MRI. A literature review of 31 cases of ectopic molar pregnancy demonstrated that lesions have been found in the fallopian tube (19 cases, 61%), ovary (5 cases, 16%), cornu (3 cases, 10%), peritoneum (2 cases, 6%), uterine cervix (1 case, 3%), and cesarean scar (1 case, 3%). Abdominal pain and abnormal vaginal bleeding were reported in 70% and 61% of the patients, respectively. Twenty-one cases (67%) presented with rupture and hemoperitoneum. All patients underwent surgical resection or dilatation and curettage. Methotrexate therapy was performed in one case because residual trophoblastic tissue was suspected. A second operation was performed in one case of ovarian molar pregnancy because serum hCG levels increased again after primary focal ovarian resection. No patients developed metastatic disease or relapsed. These findings suggest the prognosis of ectopic molar pregnancy to be favorable.

  12. Ectopic Molar Pregnancy: Diagnostic Efficacy of Magnetic Resonance Imaging and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Yasushi Yamada

    2016-01-01

    Full Text Available Ectopic molar pregnancy is extremely rare, and preoperative diagnosis is difficult. Our literature search found only one report of molar pregnancy diagnosed preoperatively. Moreover, there is no English literature depicting magnetic resonance image (MRI findings of ectopic molar pregnancy. We report a case of ectopic molar pregnancy preoperatively diagnosed using MRI. A literature review of 31 cases of ectopic molar pregnancy demonstrated that lesions have been found in the fallopian tube (19 cases, 61%, ovary (5 cases, 16%, cornu (3 cases, 10%, peritoneum (2 cases, 6%, uterine cervix (1 case, 3%, and cesarean scar (1 case, 3%. Abdominal pain and abnormal vaginal bleeding were reported in 70% and 61% of the patients, respectively. Twenty-one cases (67% presented with rupture and hemoperitoneum. All patients underwent surgical resection or dilatation and curettage. Methotrexate therapy was performed in one case because residual trophoblastic tissue was suspected. A second operation was performed in one case of ovarian molar pregnancy because serum hCG levels increased again after primary focal ovarian resection. No patients developed metastatic disease or relapsed. These findings suggest the prognosis of ectopic molar pregnancy to be favorable.

  13. Myxofibrosarcoma: prevalence and diagnostic value of the ''tail sign'' on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lefkowitz, Robert A.; Landa, Jonathan; Hwang, Sinchun; Panicek, David M.; Zabor, Emily C.; Moskowitz, Chaya S.; Agaram, Narasimhan P.

    2013-01-01

    Myxofibrosarcoma frequently shows curvilinear extensions of high T2 signal that also enhance on magnetic resonance imaging; these ''tails'' represent fascial extension of tumor at histopathological examination. This study was performed to determine whether the tail sign is helpful in distinguishing myxofibrosarcoma from other myxoid-containing neoplasms. The study group consisted of 44 patients with pathologically proven myxofibrosarcoma; the control group consisted of 52 patients with a variety of other myxoid-predominant tumors. Three musculoskeletal radiologists independently evaluated T2-weighted (and/or short-tau inversion recovery) and post-contrast MR images for the presence of one or more enhancing, high-signal intensity, curvilinear projections from the primary mass. Sensitivity and specificity for the diagnosis of myxofibrosarcoma were calculated for each reader. Interobserver variability was assessed with kappa statistic and percentage agreement. A tail sign was deemed present in 28, 30, and 34 cases of myxofibrosarcoma and in 11, 9, and 5 of the controls for the three readers respectively, yielding a sensitivity of 64-77 % and a specificity of 79-90 %. The interobserver agreement was moderate-to-substantial (kappa = 0.626). The tail sign at MRI is a moderately specific and sensitive sign for the diagnosis of myxofibrosarcoma relative to other myxoid-containing tumors. (orig.)

  14. Pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Cohen, M.D.

    1986-01-01

    This book defines the current clinical potential of magnetic resonance imaging and focuses on direct clinical work with pediatric patients. A section dealing with the physics of magnetic resonance imaging provides an introduction to enable clinicians to utilize the machine and interpret the images. Magnetic resonance imaging is presented as an appropriate imaging modality for pediatric patients utilizing no radiation

  15. Diagnostic confidence analysis in the magnetic resonance imaging of ovarian and deep endometriosis: comparison with surgical results

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Sulcis, Rosa; Ibba, Giannina; Piga, Mario [Azienda Ospedaliero Universitaria, Department of Radiology, Monserrato (Italy); Melis, Gian Benedetto; Guerriero, Stefano [Azienda Ospedaliero Universitaria, Department of Gynecology, Monserrato (Italy); Alcazar, Juan Luis [University of Navarra, Department of Obstetrics and Gynecology, Clinica Universidad de Navarra, Pamplona (Spain)

    2014-02-15

    To assess the diagnostic confidence of multiple readers in the magnetic resonance imaging (MRI) diagnosis of endometriosis. Sixty-five patients (mean age 33; range 19-45 years) who had undergone MRI were retrospectively evaluated. Five regions were analysed and the presence of endometriosis was scored on a five-point scale in order to assess the diagnostic confidence. Statistical analysis included receiver operating characteristic (ROC) curve analysis, the Cohen weighted test and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, positive likelihood ratio (LR+) and negative likelihood ratio (LR-). The areas under the curve (AUC) in the detection of ovarian endometrioma were 0.942, 0.893 and 0.883 for readers 1, 2 and 3, respectively; in the uterosacral ligament (USL) AUCs were 0.907, 0.804 and 0.842; in the vaginal fornix (VF) 0.819, 0.733 and 0.69; in the anterior compartment 0.916, 0.833 and 0.873; and in the rectum/sigma/pouch of Douglas (RSD) 0.936, 0.856 and 0.834. Diagnostic confidence of the observers is different according to the region of the nodules of endometriosis and it can be challenging in the VF and for the less experience readers also in the AC and RSD. Moreover the degree of uncertain diagnosis for the less expert readers may reach up to one third of the examinations. (orig.)

  16. Diagnostic confidence analysis in the magnetic resonance imaging of ovarian and deep endometriosis: comparison with surgical results

    International Nuclear Information System (INIS)

    Saba, Luca; Sulcis, Rosa; Ibba, Giannina; Piga, Mario; Melis, Gian Benedetto; Guerriero, Stefano; Alcazar, Juan Luis

    2014-01-01

    To assess the diagnostic confidence of multiple readers in the magnetic resonance imaging (MRI) diagnosis of endometriosis. Sixty-five patients (mean age 33; range 19-45 years) who had undergone MRI were retrospectively evaluated. Five regions were analysed and the presence of endometriosis was scored on a five-point scale in order to assess the diagnostic confidence. Statistical analysis included receiver operating characteristic (ROC) curve analysis, the Cohen weighted test and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, positive likelihood ratio (LR+) and negative likelihood ratio (LR-). The areas under the curve (AUC) in the detection of ovarian endometrioma were 0.942, 0.893 and 0.883 for readers 1, 2 and 3, respectively; in the uterosacral ligament (USL) AUCs were 0.907, 0.804 and 0.842; in the vaginal fornix (VF) 0.819, 0.733 and 0.69; in the anterior compartment 0.916, 0.833 and 0.873; and in the rectum/sigma/pouch of Douglas (RSD) 0.936, 0.856 and 0.834. Diagnostic confidence of the observers is different according to the region of the nodules of endometriosis and it can be challenging in the VF and for the less experience readers also in the AC and RSD. Moreover the degree of uncertain diagnosis for the less expert readers may reach up to one third of the examinations. (orig.)

  17. Ultrasound versus Magnetic Resonance Arthrography in Acetabular Labral Tear Diagnostics: A Prospective Comparison in 20 Dysplastic Hips

    Energy Technology Data Exchange (ETDEWEB)

    Troelsen, A.; Jacobsen, S.; Bolvig, L.; Gelineck, J.; Roemer, L.; Soeballe, K. [Orthopedic Research Unit and Dept. of Radiology, Univ. Hospital of Aarhus, A arhus (Denmark)

    2007-11-15

    Background: Acetabular labral tears are highly associated with hip dysplasia. Magnetic resonance arthrography (MR arthrography) is the expensive and time-consuming contemporary gold-standard method in the radiological assessment of acetabular labral tears. Purpose: To assess the diagnostic ability of noninvasive ultrasound (US) examination compared to MR arthrography in diagnosing acetabular labral tears in dysplastic hip joints. Material and Methods: The study compared US examination and MR arthrography diagnosis of labral tears in 20 consecutively referred dysplastic hip joints. Results: The ability to diagnose acetabular labral tears upon US examination was calculated: sensitivity 44%, specificity 75%, positive predictive value 88%, and negative predictive value 25%. Conclusion: The ability of US examination in diagnosing acetabular labral tears is not yet good enough. The technique is still to be developed, and more experience, especially with the interpretation of US examinations, is needed.

  18. Dental magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hilgenfeld, Tim; Bendszus, Martin; Haehnel, Stefan

    2016-01-01

    Growing distribution and utilization of digital volume tomography (DVT) extend the spectrum of clinical dental imaging. Additional diagnostic value, however, comes along with an increasing amount of radiation. In contrast, magnetic resonance imaging is a radiation free imaging technique. Furthermore, it offers a high soft tissue contrast. Morphological and numerical dental anomalies, differentiation of periapical lesions and exclusion of complications of dental diseases are field of applications for dental MRI. In addition, detection of caries and periodontal lesions and injury of inferior alveolar nerve are promising application areas in the future.

  19. Magnetic Resonance Neurography in Chronic Lumbosacral and Pelvic Pain: Diagnostic and Management Impact-Institutional Audit.

    Science.gov (United States)

    Dessouky, Riham; Xi, Yin; Scott, Kelly M; Khaleel, Mohammed; Gill, Kevin; Jones, Stephanie; Khalifa, Dalia N; Tantawy, Hazim I; Aidaros, Magdy A; Chhabra, Avneesh

    2018-06-01

    Low back and pelvic pain are among the most prevalent conditions worldwide, with major social and economic costs. The aim of this study was to evaluate the role of magnetic resonance neurography (MRN) of lumbosacral plexus in the management and outcomes of these patients with chronic pain. Consecutive patients with chronic lumbosacral and pelvic pain referred for MRN over a year were included. Preimaging and postimaging clinical diagnosis and treatment, pain levels, and location were recorded. Pain-free survival was compared between treatments using a Cox proportional hazards model. A total of 202 patients with mean age 53.7 ± 14.8 years and a male/female ratio of 1:1.53 were included. Of these patients, 115 presented with radiculopathy (57%), 56 with pelvic pain (28%), and 31 with groin pain (15%). Mean initial pain level was 6.9 ± 1.9. Mean symptom duration was 4.21 ± 5.86 years. Of these patients, 143 (71%) had a change in management because of MRN. After MRN, reduction in pain levels was observed in 21 of 32 patients receiving conservative treatment (66%), 42 of 67 receiving injections (63%), and 27 of 33 receiving surgery (82%). Follow-ups were available in 131 patients. Median pain-free survival was 12 months. Patients treated with surgery had significantly lower pain recurrence than patients receiving other treatments in the same time frame (hazard ratio, 3.6; 95% confidence interval, 1.4-9.2; P = 0.0061). MRN use in chronic lumbosacral and pelvic pain led to a meaningful change in diagnosis and treatment. After MRN, conservative treatment and injections provided pain relief; however, patients benefited more from surgery than from any other treatment. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Efficacy of diagnostic magnetic resonance imaging for articular cartilage lesions of the glenohumeral joint in patients with instability

    International Nuclear Information System (INIS)

    Hayes, Meredith L.; Collins, Mark S.; Wenger, Doris E.; Morgan, Joseph A.; Dahm, Diane L.

    2010-01-01

    The purpose of this study was primarily to assess the diagnostic performance of magnetic resonance imaging (MRI) in detecting articular cartilage injuries in patients with glenohumeral instability. A secondary purpose was to assess the diagnostic performance of MRI for detection of Hill-Sachs and Bankart lesions. A cohort of 87 consecutive patients who underwent diagnostic MRI and shoulder arthroscopy for instability from 1997 to 2006 were identified. Fifty-five patients (63.2%) underwent MRI with intra-articular contrast medium and 32 patients (36.8%) underwent MRI without contrast medium. MR images were reviewed by two radiologists and interpreted by consensus for the presence of articular cartilage lesions (including Hill-Sachs and Bankart lesions), which were then confirmed by reviewing the operative report and images recorded at arthroscopy. Mean patient age was 27.0 ± 10.2 years with a mean clinical and radiographic follow-up of 29 (range 3-72) months. Cartilage injuries were detected arthroscopically in 55 patients (63%). Bankart and Hill-Sachs lesions were identified arthroscopically in 66 patients (75.9%) and 55 patients (63.2%) respectively. The overall sensitivity and specificity for detection of glenohumeral articular cartilage lesions by MRI were 87.2% and 80.6% respectively. The sensitivity and specificity of MRI in detecting Bankart lesions was 98.4% (95% CI 91.9, 99.7) and 95.2% (95% CI 77.3, 99.2) respectively. The sensitivity and specificity of MRI in detecting Hill-Sachs lesions was 96.3% (95% CI 87.6, 98.9%) and 90.6% (95% CI 75.7, 96.9) respectively. No statistically significant difference was found between MRI examinations with and without intra-articular gadolinium (p = 0.89). Magnetic resonance imaging demonstrates high sensitivity and specificity for the diagnosis of articular cartilage injuries in patients with glenohumeral instability. MRI with or without intra-articular contrast medium in this study were equally reliable as a non

  1. Efficacy of diagnostic magnetic resonance imaging for articular cartilage lesions of the glenohumeral joint in patients with instability

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, Meredith L.; Collins, Mark S.; Wenger, Doris E. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Morgan, Joseph A.; Dahm, Diane L. [Mayo Clinic, Department of Orthopaedic Surgery, Rochester, MN (United States)

    2010-12-15

    The purpose of this study was primarily to assess the diagnostic performance of magnetic resonance imaging (MRI) in detecting articular cartilage injuries in patients with glenohumeral instability. A secondary purpose was to assess the diagnostic performance of MRI for detection of Hill-Sachs and Bankart lesions. A cohort of 87 consecutive patients who underwent diagnostic MRI and shoulder arthroscopy for instability from 1997 to 2006 were identified. Fifty-five patients (63.2%) underwent MRI with intra-articular contrast medium and 32 patients (36.8%) underwent MRI without contrast medium. MR images were reviewed by two radiologists and interpreted by consensus for the presence of articular cartilage lesions (including Hill-Sachs and Bankart lesions), which were then confirmed by reviewing the operative report and images recorded at arthroscopy. Mean patient age was 27.0 {+-} 10.2 years with a mean clinical and radiographic follow-up of 29 (range 3-72) months. Cartilage injuries were detected arthroscopically in 55 patients (63%). Bankart and Hill-Sachs lesions were identified arthroscopically in 66 patients (75.9%) and 55 patients (63.2%) respectively. The overall sensitivity and specificity for detection of glenohumeral articular cartilage lesions by MRI were 87.2% and 80.6% respectively. The sensitivity and specificity of MRI in detecting Bankart lesions was 98.4% (95% CI 91.9, 99.7) and 95.2% (95% CI 77.3, 99.2) respectively. The sensitivity and specificity of MRI in detecting Hill-Sachs lesions was 96.3% (95% CI 87.6, 98.9%) and 90.6% (95% CI 75.7, 96.9) respectively. No statistically significant difference was found between MRI examinations with and without intra-articular gadolinium (p = 0.89). Magnetic resonance imaging demonstrates high sensitivity and specificity for the diagnosis of articular cartilage injuries in patients with glenohumeral instability. MRI with or without intra-articular contrast medium in this study were equally reliable as a non

  2. Temporomandibular disorders – validity of clinical diagnostics compared to magnetic resonance imaging

    OpenAIRE

    BADEL, TOMISLAV; MAROTTI, MILJENKO; SAVIĆ PAVIČIN, IVANA; DULČIĆ, NIKŠA; ZADRAVEC, DIJANA; KERN, JOSIPA

    2011-01-01

    Background and Purpose: Orthopedic examination techniques of the musculoskeletal system contribute to the successful diagnostics of temporomandibular disorders (TMD). The purpose of this study is to determine the validity of TMD clinical diagnostics by comparing the findings of manual functional analysis (MFA) and the results of MRI of temporomandibular joint (TMJ). The diagnostic significance of limited mouth opening and pain upon passive mouth opening were taken into consideration. M...

  3. The progress in diagnostic imaging for staging of bladder and prostate cancer. Endorectal magnetic resonance imaging and magnetization transfer contrast

    International Nuclear Information System (INIS)

    Arima, Kiminobu; Hayashi, Norio; Yanagawa, Makoto; Kawamura, Juichi; Kobayashi, Shigeki; Takeda, Kan; Sugimura, Yoshiki

    1999-01-01

    We retrospectively studied the staging accuracy of endorectal magnetic resonance imaging (MRI) in comparison with transrectal ultrasound examination (TRUS) for 71 localized bladder cancers and 19 localized prostate cancers (PC) radically resected. The accuracy of clinical staging for bladder cancer in endorectal MRI and TRUS was 85.9% and 69.2%, respectively. The presence or absence of the continuity of submucosal enhancement on T2-weighted MRI images could be useful for the staging of bladder cancer. The accuracy of the seminal vesicular invasion for prostate cancer in endorectal MRI and TRUS was 95% and 63%, respectively. To determine whether magnetization transfer contrast (MTC) provides additional information in the diagnosis of prostate cancer, the magnetization transfer ratios (MTRs) were calculated in 22 patients with PC, 5 with benign prostatic hyperplasia (BPH) and 4 controls. The mean MTR in the peripheral zone of the normal prostate (8.0%±3.4 [standard deviation]) showed a statistically significant decrease relative to that in the inner zone of the normal prostate (27.4%±3.4, p<0.01), BPH (25.5%±3.7, p<0.01), pre-treatment PC (30.6%±5.9, p<0.01), and PC after hormonal therapy (20.3%±6.3, p<0.01). The mean MTR in pre-treatment PC was significantly higher than that in BPH, or in PC after hormonal therapy (p<0.01). MTC was considered to be useful for conspicuity of prostate cancer lesion. (author)

  4. Diagnostic value of 3D time-of-flight magnetic resonance angiography for detecting intracranial aneurysm: a meta-analysis.

    Science.gov (United States)

    HaiFeng, Liu; YongSheng, Xu; YangQin, Xun; Yu, Dou; ShuaiWen, Wang; XingRu, Lu; JunQiang, Lei

    2017-11-01

    This meta-analysis is to comprehensively evaluate the diagnostic performance of three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) for detecting intracranial aneurysm (IA). PubMed, Embase, Web of Science, and the Cochrane library were systematically searched for retrieving eligible studies. Study inclusion, data extraction, and risk of bias assessment were performed by two researchers independently. Pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated to assess the diagnostic value. In addition, heterogeneity and subgroup analysis were carried out. In total, 18 studies comprising 3463 patients were selected. The results of 3D-TOF-MRA for diagnosing IA were SEN 0.89 (95% CI 0.82-0.94), SPE 0.94 (0.86-0.97), PLR 13.79 (5.92-32.12), NLR 0.11 (0.07-0.19), DOR 121.90 (38.81-382.94), and AUC 0.96 (0.94-0.98), respectively. In the subgroup analysis, studies without subarachnoid hemorrhage (SAH) tend to perform statistical significantly better (P 3D-TOF-MRA had better SEN in aneurysms > 3 mm than the aneurysms ≤ 3 mm in diameter: 0.89 (0.87-0.92) vs. 0.78 (0.71-0.84) with P 3D-TOF-MRA has an excellent diagnostic performance for the overall assessment of IA and may serve as an alternative for further patient management with IA.

  5. Diagnostic yield of combined magnetic resonance spectroscopy and diffusion weighted imaging in intracranial neoplasms

    Directory of Open Access Journals (Sweden)

    Ayat E. El Sherbeny

    2014-09-01

    Conclusion: MRS has a robust diagnostic accuracy in cases of well defined high or low grade brain neoplasms. ADC value had the ability to confirm and differentiate low from high grade tumors in many situations where there were diagnostic confusions with MRS due to borderline values.

  6. Methodological aspects of magnetic resonance tomographic diagnostics of metastatic compressive fractures of the spine

    Directory of Open Access Journals (Sweden)

    Александр Павлович Мягков

    2015-06-01

    Full Text Available Aim of the study – to define an information value of the different pulse patterns for a qualitative estimation of MR-signals in the body of compressed vertebras.Methods: 50 patients with metastatic compressive fractures (MCF were examined using MRT. 30 (60% mans and 20 (40% woman, average age 60,8 +/- 12,5 years. Fractures in the different parts of spine were considered: cervical – 6 (12,0; thoracic – 25 (50,0 %; lumbar – 19 (38 %. Metastasis in the spine are more frequent at a cancer of mammary gland (20,0 %, kidneys (17,5 % and prostate gland (15,0 %, less frequent at a cancer of lungs, thyroid gland and sarcomas (7,5 %.MRT was done for all patients using apparatus with magnetic force 0,2, 1,5 and 0,36Т (AIRIS Mate, ECHELON of "HitachimedicalCorp.", Japan, “I-Open 0, 36” Chinein 3 projections receiving Т1-, Т2- weighted (Т1WI, Т2WI and diffusion-weighted images (DWIand also images with suppression of signals from an adipose tissue (STIR, Fat/sat.Results: the more obvious pulse patterns (PP at MCF of spine are – STIR (97,8 %, Т1WI и DWI (80 %. DWI can be used as a screening and addition for above-listed PP. The more objective criterion for a judgment about MCF is abnormal uptake of CM (60 % on diffuse type.Conclusions: for MRT visualization of MCF the most optimal are the next PP – STIR, Т1WI and DWI, with a sensitivity, respectively – 97,8 %, 80 %, and 80 %. DWI must supplement but not substitute all existing PP. On the post-contrast T1WI an objective criterion for MRT diagnostics of MCF is an abnormal uptake of CM on diffuse type. An alteration of signal characteristics in the body of compressed vertebras is an evidence of an alteration of structure, but for more precise definition of its character it is necessary to study its morphological alterations

  7. Nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Cremin, B.J.

    1981-01-01

    Recent advances in diagnostic imaging, have been the medical application of nuclear magnetic resonance (NMR). It's been used to study the structure of various compounds in chemistry and physics, and in the mid-1970 to produce images of rabbits and eventually of the human hand and head. The images are produced by making use of the nuclear magnetization of the hydrogen ion, or proton, that is present in biological material to record the density distribution of protons in cellular water and lipids. An exploration of the end-results of complicated free induction decay signals, that have been digitized and frequency-analysed by mathematical computerized techniques to produce an image of tissue density, is given. At present NMR produces images comparable to those of early computed tomography

  8. Brain Atlas Fusion from High-Thickness Diagnostic Magnetic Resonance Images by Learning-Based Super-Resolution.

    Science.gov (United States)

    Zhang, Jinpeng; Zhang, Lichi; Xiang, Lei; Shao, Yeqin; Wu, Guorong; Zhou, Xiaodong; Shen, Dinggang; Wang, Qian

    2017-03-01

    It is fundamentally important to fuse the brain atlas from magnetic resonance (MR) images for many imaging-based studies. Most existing works focus on fusing the atlases from high-quality MR images. However, for low-quality diagnostic images (i.e., with high inter-slice thickness), the problem of atlas fusion has not been addressed yet. In this paper, we intend to fuse the brain atlas from the high-thickness diagnostic MR images that are prevalent for clinical routines. The main idea of our works is to extend the conventional groupwise registration by incorporating a novel super-resolution strategy. The contribution of the proposed super-resolution framework is two-fold. First, each high-thickness subject image is reconstructed to be isotropic by the patch-based sparsity learning. Then, the reconstructed isotropic image is enhanced for better quality through the random-forest-based regression model. In this way, the images obtained by the super-resolution strategy can be fused together by applying the groupwise registration method to construct the required atlas. Our experiments have shown that the proposed framework can effectively solve the problem of atlas fusion from the low-quality brain MR images.

  9. Diagnostic accuracy and prognostic impact of restaging by magnetic resonance imaging after preoperative chemoradiotherapy in patients with rectal cancer

    International Nuclear Information System (INIS)

    Huh, Jung Wook; Kim, Hee Cheol; Lee, Soon Jin; Yun, Seong Hyeon; Lee, Woo Yong; Park, Yoon Ah; Cho, Yong Beom; Chun, Ho-Kyung

    2014-01-01

    Background: The prognostic role of restaging rectal magnetic resonance imaging (MRI) in patients with preoperative CRT has not been established. The goal of this study was to evaluate the diagnostic accuracy and prognostic role of radiological staging by rectal MRI after preoperative chemoradiation (CRT) in patients with rectal cancer. Methods: A total of 231 consecutive patients with rectal cancer who underwent preoperative CRT and radical resection from January 2008 to December 2009 were prospectively enrolled. The diagnostic accuracy and prognostic significance of post-CRT radiological staging by MRI was evaluated. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of radiological diagnosis of good responders (ypTNM stage 0–I) were 32%, 90%, 65%, and 69%, respectively. The overall accuracy of MRI restating for good responders was 68%. The 5-year disease-free survival rates of patients with radiological and pathological TNM stage 0, stage I, and stage II–III were 100%, 94%, and 76%, respectively (P = 0.037), and 97%, 87%, and 73%, respectively (P = 0.007). On multivariate analysis, post-CRT radiological staging by MRI was an independent prognostic factor for disease-free survival. Conclusion: Radiological staging by MRI after preoperative CRT may be an independent predictor of survival in patients with rectal cancer

  10. Magnetic resonance imaging apparatus

    International Nuclear Information System (INIS)

    Ehnholm, G.J.

    1991-01-01

    This patent describes an electron spin resonance enhanced magnetic resonance (MR) imaging (ESREMRI) apparatus able to generate a primary magnetic field during periods of nuclear spin transition excitation and magnetic resonance signal detection. This allows the generation of ESREMRI images of a subject. A primary magnetic field of a second and higher value generated during periods of nuclear spin transition excitation and magnetic resonance signal detection can be used to generate conventional MR images of a subject. The ESREMRI and native MR images so generated may be combined, (or superimposed). (author)

  11. Diagnostic accuracy of magnetic resonance, computed tomography and contrast enhanced ultrasound in radiological multimodality assessment of peribiliary liver metastases.

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    Full Text Available We compared diagnostic performance of Magnetic Resonance (MR, Computed Tomography (CT and Ultrasound (US with (CEUS and without contrast medium to identify peribiliary metastasis.We identified 35 subjects with histological proven peribiliary metastases who underwent CEUS, CT and MR study. Four radiologists evaluated the presence of peribiliary lesions, using a 4-point confidence scale. Echogenicity, density and T1-Weigthed (T1-W, T2-W and Diffusion Weighted Imaging (DWI signal intensity as well as the enhancement pattern during contrast studies on CEUS, CT and MR so as hepatobiliary-phase on MRI was assessed.All lesions were detected by MR. CT detected 8 lesions, while US/CEUS detected one lesion. According to the site of the lesion, respect to the bile duct and hepatic parenchyma: 19 (54.3% were periductal, 15 (42.8% were intra-periductal and 1 (2.8% was periductal-intrahepatic. According to the confidence scale MRI had the best diagnostic performance to assess the lesion. CT obtained lower diagnostic performance. There was no significant difference in MR signal intensity and contrast enhancement among all metastases (p>0.05. There was no significant difference in CT density and contrast enhancement among all metastases (p>0.05.MRI is the method of choice for biliary tract tumors but it does not allow a correct differential diagnosis among different histological types of metastasis. The presence of biliary tree dilatation without hepatic lesions on CT and US/CEUS study may be an indirect sign of peribiliary metastases and for this reason the patient should be evaluated by MRI.

  12. Clinical diagnostic study by means of magnetic resonance imaging for lesions of the major salivary gland region

    International Nuclear Information System (INIS)

    Iihama, Tsuyoshi; Mataga, Izumi; Kato, Joji

    1994-01-01

    The diagnostic value of magnetic resonance imaging (MRI) for lesions situated in the major salivary glands was clinically discussed in this study. A total of 46 patients with salivary gland disorders treated in our department over the past five years were assessed by mean of MRI, and in 11 patients the findings were compared with the histopathological features of lesions sectioned at the same level postoperatively. In addition, preliminary investigations to introduce a new qualitative diagnostic procedure for estimation of salivary gland function in geriatric patients were attempted. In this investigation, T 1 and T 2 values, and signal intensity ratios of the submandibular gland were measured in elderly patients complaining of dry mouth and in healthy controls. Likewise, salivary gland function was examined by taste stimulation induced by applying citric acid to the tongue surface just before starting MRI. MRI clearly demonstrated lesions in the salivary glands. The histopathological diagnosis could not be accurately predicted by signal intensity. However, benign tumors showed higher intensity signals than did malignant tumors on T 2 -weighted images. Cystic lesions could be differentiated from tumors by signal intensity. Histopathological features of salivary gland tumors corresponded to the MRI signal intensity. Relaxation times of T 1 and T 2 values and signal intensity in each major salivary gland were diminished in elderly patients in a resting condition. Only T 1 values in healthy subjects remarkably responded to taste stimulation. These results suggest that MRI is useful and beneficial not only in the qualitative diagnosis of tumors arising from salivary glands but also in the estimation of salivary gland function. MRI should therefore be included in routine diagnostic examinations for salivary gland disorders. (author)

  13. Possibilities of computer and magnetic-resonance tomography in liver neoplasm diagnostics

    International Nuclear Information System (INIS)

    Momot, N.V.; Shpak, S.A.

    2003-01-01

    With the purpose of comparison of CT and MRI possibilities in diagnostics of focal liver lesions 238 patients were studied by CT and 38 - by MRI. Results of investigation were verified by surgery, needle-fine biopsy, dynamic observation. CT is a method of a choice in diagnostics of focal liver lesions. MRI has some advantages in revealing of small metastases and neoplasms located on diaphragmal surface of the liver, in evaluation of hepatic portal structures and tumor relation with surrounding tissues and vessels

  14. Diagnostic value of 3D time-of-flight magnetic resonance angiography for detecting intracranial aneurysm: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Liu, HaiFeng; Xu, YongSheng [First Hospital of LanZhou University, Department of Radiology, Lanzhou, Gansu (China); First Clinical Medical College of LanZhou University, Lanzhou, Gansu (China); Xun, YangQin [Lanzhou University, Evidence-based Medicine Center, Lanzhou (China); Dou, Yu; Wang, ShuaiWen; Lu, XingRu; Lei, JunQiang [First Hospital of LanZhou University, Department of Radiology, Lanzhou, Gansu (China)

    2017-11-15

    This meta-analysis is to comprehensively evaluate the diagnostic performance of three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) for detecting intracranial aneurysm (IA). PubMed, Embase, Web of Science, and the Cochrane library were systematically searched for retrieving eligible studies. Study inclusion, data extraction, and risk of bias assessment were performed by two researchers independently. Pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated to assess the diagnostic value. In addition, heterogeneity and subgroup analysis were carried out. In total, 18 studies comprising 3463 patients were selected. The results of 3D-TOF-MRA for diagnosing IA were SEN 0.89 (95% CI 0.82-0.94), SPE 0.94 (0.86-0.97), PLR 13.79 (5.92-32.12), NLR 0.11 (0.07-0.19), DOR 121.90 (38.81-382.94), and AUC 0.96 (0.94-0.98), respectively. In the subgroup analysis, studies without subarachnoid hemorrhage (SAH) tend to perform statistical significantly better (P < 0.05) in detecting IAs than studies with SAH 0.99 (0.98-1.00) vs. 0.89 (0.86-0.91). The diagnostic value of studies with a two-image reconstruction method was higher than studies with only one image reconstruction method: 0.99 (0.98-1.00) vs. 0.91 (0.89-0.94) with P < 0.05. The 3D-TOF-MRA had better SEN in aneurysms > 3 mm than the aneurysms ≤ 3 mm in diameter: 0.89 (0.87-0.92) vs. 0.78 (0.71-0.84) with P < 0.05. This study demonstrated that 3D-TOF-MRA has an excellent diagnostic performance for the overall assessment of IA and may serve as an alternative for further patient management with IA. (orig.)

  15. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  16. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, Farshid [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom); North Cumbria University Hospitals, Department of Radiology, Carlisle (United Kingdom); Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom)

    2013-09-15

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  17. Diagnostic value and prognostic implications of early cardiac magnetic resonance in survivors of out-of-hospital cardiac arrest.

    Science.gov (United States)

    Zorzi, Alessandro; Susana, Angela; De Lazzari, Manuel; Migliore, Federico; Vescovo, Giovanni; Scarpa, Daniele; Baritussio, Anna; Tarantini, Giuseppe; Cacciavillani, Luisa; Giorgi, Benedetta; Basso, Cristina; Iliceto, Sabino; Bucciarelli Ducci, Chiara; Corrado, Domenico; Marra, Martina Perazzolo

    2018-03-15

    In patients who survived out-of-hospital cardiac arrest (OHCA), it is crucial to establish the underlying cause and its potential reversibility. The purpose of this study was to assess the incremental diagnostic and prognostic role of early cardiac magnetic resonance (CMR) in survivors of OHCA. Among 139 consecutive OHCA patients, the study enrolled 44 patients (median age 43 years; 84% male) who underwent coronary angiography and CMR ≤7 days after admission. The CMR protocol included T2-weighted sequences for myocardial edema and late gadolinium enhancement (LGE) sequences for myocardial fibrosis. Coronary angiography identified obstructive coronary artery disease in 18 of 44 patients in whom CMR confirmed the diagnosis of ischemic heart disease by demonstrating subendocardial or transmural LGE. The presence of myocardial edema allowed differentiation between acute myocardial ischemia (n = 12) and postinfarction myocardial scar (n = 6). Among the remaining 26 patients without obstructive coronary artery disease, CMR in 19 (73%) showed dilated cardiomyopathy in 5, myocarditis in 4, mitral valve prolapse associated with LGE in 3, ischemic scar in 2, idiopathic nonischemic scar in 2, arrhythmogenic cardiomyopathy in 1, hypertrophic cardiomyopathy in 1, and takotsubo cardiomyopathy in 1. In this subgroup of 26 patients, 6 (23%) had myocardial edema. During mean follow-up of 36 ± 17 months, all 18 patients with myocardial edema had an uneventful outcome, whereas 9 of 26 (35%) without myocardial edema experienced sudden arrhythmic death (n = 1), appropriate defibrillator interventions (n = 5), and nonarrhythmic death (n = 3; P = .006). In survivors of OHCA, early CMR with a comprehensive tissue characterization protocol provided additional diagnostic and prognostic value. The identification of myocardial edema was associated with a favorable long-term outcome. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    International Nuclear Information System (INIS)

    Fallahi, Farshid; Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon

    2013-01-01

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  19. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn's Disease.

    Science.gov (United States)

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-04-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn's disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-valuewomen with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease.

  20. Determination of hemispheric language dominance in the surgical epilepsy patient: diagnostic properties of functional magnetic resonance imaging.

    Science.gov (United States)

    Spritzer, Scott D; Hoerth, Matthew T; Zimmerman, Richard S; Shmookler, Aaron; Hoffman-Snyder, Charlene R; Wellik, Kay E; Demaerschalk, Bart M; Wingerchuk, Dean M

    2012-09-01

    Presurgical evaluation for refractory epilepsy typically includes assessment of cognitive and language functions. The reference standard for determination of hemispheric language dominance has been the intracarotid amobarbital test (IAT) but functional magnetic resonance imaging (fMRI) is increasingly used. To critically assess current evidence regarding the diagnostic properties of fMRI in comparison with the IAT for determination of hemispheric language dominance. The objective was addressed through the development of a structured critically appraised topic. This included a clinical scenario, structured question, literature search strategy, critical appraisal, results, evidence summary, commentary, and bottom-line conclusions. Participants included consultant and resident neurologists, a medical librarian, clinical epidemiologists, and content experts in the fields of epilepsy and neurosurgery. A systematic review and meta-analysis that compared the sensitivity and specificity of fMRI to IAT-determined language lateralization was selected for critical appraisal. The review included data from 23 articles (n=442); study methodology varied widely. fMRI was 83.5% sensitive and 88.1% specific for detection of hemispheric language dominance. There are insufficient data to support routine use of fMRI for the purpose of determining hemispheric language dominance in patients with intractable epilepsy. Larger, well-designed studies of fMRI for language and other cognitive outcomes as part of the presurgical and postsurgical evaluation of epilepsy patients are necessary.

  1. [Magnetic resonance semiotics of prostate cancer according to the PI-RADS classification. The clinical diagnostic algorithm of a study].

    Science.gov (United States)

    Korobkin, A S; Shariya, M A; Chaban, A S; Voskanvan, G A; Vinarov, A Z

    2015-01-01

    to elaborate the magnetic resonance imaging (MRI) signs of prostate cancer (PC) in accordance with the PI-RADS classification during multiparametric MRI (mpMRI). A total of 89 men aged 20 to 82 years were examined. A control group consisted of 8 (9%) healthy volunteers younger than 30 years of age with no urological history to obtain control images and MRI plots and 20 (22.5%) men aged 26-76 years, whose morphological changes were inflammatory and hyperplastic. The second age-matched group included 61 (68.5%) patients diagnosed with prostate cancer at morphological examination. A set of studies included digital rectal examination, serum prostate-specific antigen, and transrectal ultrasound-guided prostate biopsy. All the patients underwent prostate mpMRI applying a 3.0 T Achieva MRI scanner (Philips, the Netherlands). The patients have been found to have mpMRI signs that were typical of PC; its MRI semiotics according to the PI-RADS classification is presented. Each mpMRI procedure has been determined to be of importance and informative value in detecting PC. The comprehensive mpMRI approach to diagnosing PC improves the quality and diagnostic value of prostate MRI.

  2. Magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Meyerhoff, D.J.; Weiner, M.W.

    1989-01-01

    A major function of the liver is regulation of carbohydrate, lipid, and nitrogen metabolism. Food is absorbed by the intestines and transported to the liver by the portal circulation. Substrates are metabolized and stored in the liver to maintain optimal blood concentrations of glucose and lipids. Ammonia generated in the gastrointestinal tract is converted to urea in the liver by the urea cycle. Various forms of liver disease are associated with disorders of carbohydrate, fat, and nitrogen metabolism. Therefore the ability to characterize liver metabolism noninvasively is of potential diagnostic value. Magnetic resonance spectroscopy (MRS) provides information about tissue metabolism by measuring concentrations of metabolites. However, to determine the anatomic location from which spectroscopic signals are derived, MRS could be performed in conjunction with MRI. This paper summarizes the current experience with spectroscopy ion animal models of human disease and reviews the clinical experience with hepatic MRS to date

  3. Magnetic resonance imaging and biomarkers of serum and urine wile diagnostics of kidney cancer

    Directory of Open Access Journals (Sweden)

    Nickolsky Yu.Ye.

    2016-03-01

    Full Text Available Purpose: improvement of differential diagnostics of benign and malignant renal tumors basing on complex estimation of the results of MRTand the level of such biomarkers as vascular endothelial growth factor, monocyte chemotactic protein-1 and matrix metalloproteinase-9 in blood serum and urine. Material and Methods. A total of 106 patients including the main group of 60 patients with renal cancer (RC, the group of comparison of 16 patients with benign renal tumors and the control group of 30 practically healthy persons were examined. ELISA was employed for detection of the biomarkers in blood serum and urine. The tumors were diagnosed by MRT Results. The increase of the level of the biomarkers in blood serum and urine was registered independently of the character of neoplastic process; more significant increase was observed in patients with RC, especially at the early stages of the disease. Some peculiarities of changing of the level of the biomarkers depending on the dimensions of malignant tumors were found. Conclusion. At the early stages of RC complex detection of the abovementioned biomarkers in blood serum and urine can serve an additional clinical diagnostic and prognostic criterion.

  4. The diagnostic value of diffusion-weighted magnetic resonance imaging in soft tissue abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Unal, Ozkan; Koparan, Halil Ibrahim [Yuezuencue Yil University, Department of Radiology, Van (Turkey); Avcu, Serhat, E-mail: serhatavcu@hotmail.com [Yuezuencue Yil University, Department of Radiology, Van (Turkey); Kalender, Ali Murat [Yuezuencue Yil University, Department of Orthopaedics, General Surgery, Van (Turkey); Kisli, Erol [Yuezuencue Yil University, Department of General Surgery, Van (Turkey)

    2011-03-15

    Purpose: To study the diagnostic value of diffusion-weighted imaging (DWI) in soft tissue abscesses. Materials and methods: Fifty patients were included in this study who were thought to have soft tissue abscess or cystic lesion as a result of clinical and radiological examinations. Localisations of the lesions were: 1 periorbital, 3 breast, 14 intraabdominal, and 32 intramuscular lesions. After other radiological examinations, DWI was performed. The signal intensity values of the lesions were evaluated qualitatively according to the hyperintensity on b-1000 DWI, using 1.5 T MR system. All of the lesions were aspirated after DWI, and detection of pus in the aspiration material was accepted as gold standard for the diagnosis of abscess. Results: In 38 of the 50 patients, hyperintensity was obtained on diffusion-weighted images. False-positive results were maintained in 2 of these patients, and true-positive results were maintained in 36 of them. In 11 of the 50 patients, hypointensity was visualised on diffusion-weighted images. False-negative results were maintained in 3 of these patients, and true-negative results were maintained in 8 of them. An abscess which was seen on post-contrast conventional MRI could not be seen on DWI, and this was regarded as false-negative. Conclusion: The sensitivity and specificity of diffusion-weighted images for detecting soft tissue abscesses were found to be 92% and 80%, respectively. DWI has a high diagnostic value in soft tissue abscesses, and is an important imaging modality that may be used for the differentiation of cysts and abscesses.

  5. The diagnostic value of diffusion-weighted magnetic resonance imaging in soft tissue abscesses

    International Nuclear Information System (INIS)

    Unal, Ozkan; Koparan, Halil Ibrahim; Avcu, Serhat; Kalender, Ali Murat; Kisli, Erol

    2011-01-01

    Purpose: To study the diagnostic value of diffusion-weighted imaging (DWI) in soft tissue abscesses. Materials and methods: Fifty patients were included in this study who were thought to have soft tissue abscess or cystic lesion as a result of clinical and radiological examinations. Localisations of the lesions were: 1 periorbital, 3 breast, 14 intraabdominal, and 32 intramuscular lesions. After other radiological examinations, DWI was performed. The signal intensity values of the lesions were evaluated qualitatively according to the hyperintensity on b-1000 DWI, using 1.5 T MR system. All of the lesions were aspirated after DWI, and detection of pus in the aspiration material was accepted as gold standard for the diagnosis of abscess. Results: In 38 of the 50 patients, hyperintensity was obtained on diffusion-weighted images. False-positive results were maintained in 2 of these patients, and true-positive results were maintained in 36 of them. In 11 of the 50 patients, hypointensity was visualised on diffusion-weighted images. False-negative results were maintained in 3 of these patients, and true-negative results were maintained in 8 of them. An abscess which was seen on post-contrast conventional MRI could not be seen on DWI, and this was regarded as false-negative. Conclusion: The sensitivity and specificity of diffusion-weighted images for detecting soft tissue abscesses were found to be 92% and 80%, respectively. DWI has a high diagnostic value in soft tissue abscesses, and is an important imaging modality that may be used for the differentiation of cysts and abscesses.

  6. Crohn's Disease Evaluated with Magnetic Resonance Enteroclysis: Diagnostic Performance of Experienced and Inexperienced Readers before and after Training

    International Nuclear Information System (INIS)

    Negaard, A.; Mulahasanovic, A.; Reisaeter, L.A.; Aasekjaer, K.; Sandvik, L.; Klow, N.E.

    2008-01-01

    Background: Magnetic resonance enteroclysis (MRE) is suggested to become the preferred radiological method in small-bowel Crohn's disease (CD). However, the performance of inexperienced readers may influence the diagnostic value of the method and has not been previously investigated. Purpose: To compare readings of MRE in small-bowel CD performed by experienced and inexperienced readers before and after training.Material and Methods: One experienced radiologist (observer 1) and two trainees (observers 2 and 3) reviewed 60 MRE examinations. A second reading was performed after training. Bowel wall thickness (BWT), ulcers (BWU), stenosis (BWS), fistulas (FIS), and abscesses (ABS) were evaluated. A reference standard based on clinical records was established. Results: BWT in the terminal ileum was evaluated with high diagnostic performance (sensitivity: observer 1, 83%; observer 2, 72%; observer 3, 78%). Only BWU was diagnosed with a higher sensitivity by observer 1 (78% vs. 33% and 39%, respectively; P=0.02). False-positive findings for BWT in the jejunum (observer 2: 7; observer 3: 4) and fistulas and abscesses (observer 2: 11/5; observer 3: 5/4) were made by the trainees. Interobserver agreement in the jejunum was poor (observer 1/observer 2: κ=0.23; observer 1/observer 3: κ=-0.03) and in the ileum good (observer 1/observer 2: κ=0.78; observer 1/observer 3: κ=0.73). After training, evaluation of BWU (observer 2: 56%, P=0.22; observer 3: 44%, P=0.03), BWT (observer 2: 2; observer 3: 2), and interobserver agreement in the jejunum improved (observer 1/observer 2: κ=0.66; observer 1/observer 3: κ=0.66). However, the number of diagnosed fistulas and abscesses remained high. Conclusion: Before training, most findings of Crohn's disease in the terminal ileum were evaluated with high diagnostic performance by all readers. However, the inexperienced readers evaluated BWU with a low sensitivity and overestimated the number of FIS, number of ABS, and increased BWT in

  7. T1 mapping cardiovascular magnetic resonance imaging to detect myocarditis—Impact of slice orientation on the diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Bohnen, Sebastian, E-mail: s.bohnen@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Radunski, Ulf K., E-mail: u.radunski@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Lund, Gunnar K., E-mail: glund@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Tahir, Enver, E-mail: e.tahir@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Avanesov, Maxim, E-mail: m.avanesov@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Stehning, Christian, E-mail: christian.stehning@philips.com [Philips Research, Hamburg (Germany); Schnackenburg, Bernhard, E-mail: bernhard.schnackenburg@philips.com [Philips Healthcare Germany, Hamburg (Germany); Adam, Gerhard, E-mail: g.adam@uke.de [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Blankenberg, Stefan, E-mail: s.blankenberg@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany); Muellerleile, Kai, E-mail: kamuellerleile@uke.de [University Medical Center Hamburg-Eppendorf, University Heart Center, General and Interventional Cardiology, Hamburg (Germany)

    2017-01-15

    Background: T1 mapping is a promising diagnostic tool to improve the diagnostic accuracy of cardiovascular magnetic resonance (CMR) in patients with suspected myocarditis. However, there are currently no data on the potential influence of slice orientation on the diagnostic performance of CMR. Thus, we compared the diagnostic performance of global myocardial T1 and extracellular volume (ECV) values to differentiate patients with myocarditis from healthy individuals between different slice orientations. Methods: This study included 48 patients with clinically defined myocarditis and 13 healthy controls who underwent CMR at 1.5 T. A modified Look-Locker inversion-recovery (MOLLI) sequence was used for T1 mapping before and 15 min after administration of 0.075 mmol/kg Gadolinium-BOPTA. T1 mapping was performed on three short and on three long axes slices, respectively. Native T1, post-contrast T1 and extracellular volume (ECV) −BOPTA maps were calculated using a dedicated plug-in written for the OsiriX software and compared between the mean value of three short-axes slices (3SAX), the central short-axis (1SAX), the mean value of three long-axes slices (3LAX), the four-chamber view (4CH), the three-chamber view (3CH) and the two-chamber view (2CH). Results: There were significantly lower native T1 values on 3LAX (1081 ms (1037–1131 ms)) compared to 3SAX (1107 ms (1069–1143 ms), p = 0.0022) in patients with myocarditis, but not in controls (1026 ms (1009–1059 ms) vs. 1039 ms (1023–1055 ms), p = 0.2719). The areas under the curve (AUC) to discriminate between myocarditis and healthy controls by native myocardial T1 were 0.85 (p < 0.0001) on 3SAX, 0.85 (p < 0.0001) on 1SAX, 0.76 (p = 0.0002) on 3LAX, 0.70 (p = 0.0075) on 4CH, 0.72 (p = 0.0020) on 3CH and 0.75 (p = 0.0003) on 2CH. The AUCs for ECV-BOPTA were 0.83 (p < 0.0001) on 3 SAX, 0.82 (p < 0.0001) on 1SAX, 0.77 (p = 0.0005) on 3LAX, 0.71 (p = 0.0079) on 4CH, 0.69 (p = 0.0371) on 3CH and 0.75 (p = 0.0006) on

  8. T1 mapping cardiovascular magnetic resonance imaging to detect myocarditis—Impact of slice orientation on the diagnostic performance

    International Nuclear Information System (INIS)

    Bohnen, Sebastian; Radunski, Ulf K.; Lund, Gunnar K.; Tahir, Enver; Avanesov, Maxim; Stehning, Christian; Schnackenburg, Bernhard; Adam, Gerhard; Blankenberg, Stefan; Muellerleile, Kai

    2017-01-01

    Background: T1 mapping is a promising diagnostic tool to improve the diagnostic accuracy of cardiovascular magnetic resonance (CMR) in patients with suspected myocarditis. However, there are currently no data on the potential influence of slice orientation on the diagnostic performance of CMR. Thus, we compared the diagnostic performance of global myocardial T1 and extracellular volume (ECV) values to differentiate patients with myocarditis from healthy individuals between different slice orientations. Methods: This study included 48 patients with clinically defined myocarditis and 13 healthy controls who underwent CMR at 1.5 T. A modified Look-Locker inversion-recovery (MOLLI) sequence was used for T1 mapping before and 15 min after administration of 0.075 mmol/kg Gadolinium-BOPTA. T1 mapping was performed on three short and on three long axes slices, respectively. Native T1, post-contrast T1 and extracellular volume (ECV) −BOPTA maps were calculated using a dedicated plug-in written for the OsiriX software and compared between the mean value of three short-axes slices (3SAX), the central short-axis (1SAX), the mean value of three long-axes slices (3LAX), the four-chamber view (4CH), the three-chamber view (3CH) and the two-chamber view (2CH). Results: There were significantly lower native T1 values on 3LAX (1081 ms (1037–1131 ms)) compared to 3SAX (1107 ms (1069–1143 ms), p = 0.0022) in patients with myocarditis, but not in controls (1026 ms (1009–1059 ms) vs. 1039 ms (1023–1055 ms), p = 0.2719). The areas under the curve (AUC) to discriminate between myocarditis and healthy controls by native myocardial T1 were 0.85 (p < 0.0001) on 3SAX, 0.85 (p < 0.0001) on 1SAX, 0.76 (p = 0.0002) on 3LAX, 0.70 (p = 0.0075) on 4CH, 0.72 (p = 0.0020) on 3CH and 0.75 (p = 0.0003) on 2CH. The AUCs for ECV-BOPTA were 0.83 (p < 0.0001) on 3 SAX, 0.82 (p < 0.0001) on 1SAX, 0.77 (p = 0.0005) on 3LAX, 0.71 (p = 0.0079) on 4CH, 0.69 (p = 0.0371) on 3CH and 0.75 (p = 0.0006) on

  9. Diagnostic performance of radiographers as compared to radiologists in magnetic resonance colonography

    International Nuclear Information System (INIS)

    Zijta, F.M.; Florie, J.; Jensch, S.; Bipat, S.; Nievelstein, R.A.J.; Poulus, M.; Thomassen-de Graaf, M.A.; Montauban van Swijndregt, A.D.; Stoker, J.

    2010-01-01

    Purpose: To evaluate the diagnostic performance of radiographers compared to radiologists in the detection of colorectal lesions in MR colonography. Material and methods: 159 patients at increased risk of colorectal cancer were included. Four different experienced observers, one MR radiologist, one radiologist in training and two radiographers evaluated all MR colonography examinations. The protocol included T1-weighted and T2-weighted sequences in prone and supine position. Colonoscopy was used as reference standard. Mean sensitivity rates with 95% confidence intervals (CIs) were determined on a per-patient and per-polyp basis, segmented by size (≥6 mm and ≥10 mm). Specificity was calculated on a per-patient basis. The McNemar and chi-square (χ 2 ) test was used to determine significant differences. Results: At colonoscopy 74 patients (47%) had normal findings; 23 patients had 40 polyps with a size ≥6 mm. In 10 patients at least 1 polyp ≥10 mm was found (20 polyps in total). Similar sensitivities for patients with lesions ≥10 mm were found for radiologists and radiographers (65% (95%CI: 44-86%) vs. 50% (95%CI: 28-72%)) (p = n.s.). For lesions ≥10 mm combined per-patient specificity for radiologists and radiographers was 96% (95%CI: 94-98%) and 73% (95%CI: 68-79%) (p < 0.0001). Combined per-patient sensitivity for lesions ≥6 mm differed significantly between both groups of observers (57% (95%CI: 42-71%) vs. 33% (95%CI: 19-46%)) (p = 0.03). Conclusion: Radiographers have comparable sensitivity but lower specificity relative to radiologists in the detection of colorectal lesions ≥10 mm at MR colonography. Adequate training in evaluating MR colonography is necessary, especially for readers with no prior experience with colonography.

  10. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  11. Single voxel magnetic resonance spectroscopy in distinguishing ...

    African Journals Online (AJOL)

    Objective: Assess diagnostic utility of combined magnetic resonance imaging and magnetic resonance spectroscopy (MRI, MRS) in differentiating focal neoplastic lesions from focal non- neoplastic (infective or degenerative) brain lesions. Design: Descriptive, analytical - prospective study. Setting: The Aga Khan University ...

  12. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  13. Troponin-positive chest pain with unobstructed coronary arteries: incremental diagnostic value of cardiovascular magnetic resonance imaging.

    Science.gov (United States)

    Pathik, Bhupesh; Raman, Betty; Mohd Amin, Nor Hanim; Mahadavan, Devan; Rajendran, Sharmalar; McGavigan, Andrew D; Grover, Suchi; Smith, Emma; Mazhar, Jawad; Bridgman, Cameron; Ganesan, Anand N; Selvanayagam, Joseph B

    2016-10-01

    Troponin-positive chest pain patients with unobstructed coronaries represent a clinical dilemma. Cardiovascular magnetic resonance (CMR) imaging has an increasingly prominent role in the assessment of these patients; however, its utility in addition to expert clinical judgement is unclear. We sought to determine the incremental diagnostic value of CMR and the heterogeneity in diagnoses by experienced cardiologists when presented with blinded clinical and investigative data in this population. A total of 125 consecutive patients presenting to a tertiary centre between 2010 and 2014 with cardiac chest pain, elevated troponin (>29 ng/L), and unobstructed coronaries were enrolled and underwent CMR. A panel of three experienced cardiologists unaware of the CMR diagnosis and blinded to each other's assessment provided a diagnosis based on clinical and investigative findings. A consensus panel diagnosis was defined as two or more cardiologists sharing the same clinical diagnosis. Findings were classified into acute myocarditis, Takotsubo cardiomyopathy, acute myocardial infarction (AMI), or indeterminate. CMR provided a diagnosis in 87% of patients. Consensus panel diagnosis and CMR were concordant in 65/125 (52%) patients. There was an only moderate level of agreement between the three cardiologists (k = 0.47, P < 0.05) and a poor level of agreement between the consensus panel and CMR (k = 0.38, P < 0.05) with the most disagreement seen in patients with AMI diagnosed on CMR. The clinical diagnosis of patients with non-obstructive coronaries and positive troponin remains a challenge. The concordance between CMR and clinical diagnosis is poor. CMR provides a diagnosis in majority of these patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  14. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn’s Disease

    Science.gov (United States)

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-01-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn’s disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-value<0.05 was considered as statistically significant. RESULTS Of the 30 patients with active CD, 11(36.7%) were men and 19 (63.3%) were women with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease. PMID:27252815

  15. Diagnostic contribution of cardiac magnetic resonance in patients with acute coronary syndrome and culprit-free angiograms.

    Science.gov (United States)

    Kawecki, Damian; Morawiec, Beata; Monney, Pierre; Pellaton, Cyril; Wojciechowska, Celina; Jojko, Joanna; Basiak, Marcin; Przywara-Chowaniec, Brygida; Fournier, Stephane; Nowalany-Kozielska, Ewa; Schwitter, Juerg; Muller, Olivier

    2015-01-14

    In spite of robust knowledge about underlying ischemic myocardial damage, acute coronary syndromes (ACS) with culprit-free angiograms raise diagnostic concerns. The present study aimed to evaluate the additional value of cardiac magnetic resonance (CMR) over commonly available non-CMR standard tests, for the differentiation of myocardial injury in patients with ACS and non-obstructed coronary arteries. Patients with ACS, elevated hs-TnT, and a culprit-free angiogram were prospectively enrolled into the study between January 2009 and July 2013. After initial evaluation with standard tests (ECG, echocardiography, hs-TnT) and provisional exclusion of acute myocardial infarction (AMI) in coronary angiogram, patients were referred for CMR with the suspicion of myocarditis or Takotsubo cardiomyopathy (TTC). According to the result of CMR, patients were reclassified as having myocarditis, AMI, TTC, or non-injured myocardium as assessed by late gadolinium enhancement. Out of 5110 patients admitted with ACS, 75 had normal coronary angiograms and entered the study; 69 of them (92%) were suspected for myocarditis and 6 (8%) for TTC. After CMR, 49 patients were finally diagnosed with myocarditis (65%), 3 with TTC (4%), 7 with AMI (9%), and 16 (21%) with non-injured myocardium. The provisional diagnosis was changed or excluded in 23 patients (31%), with a 9% rate of unrecognized AMI. The study results suggest that the evaluation of patients with ACS and culprit-free angiogram should be complemented by a CMR examination, if available, because the initial work-up with non-CMR tests leads to a significant proportion of misdiagnosed AMI.

  16. Magnetic Resonance (MR) Defecography

    Science.gov (United States)

    ... to a CD or uploaded to a digital cloud server. Magnetic resonance (MR) defecography is a special ... with you. top of page What are the benefits vs. risks? Benefits MR defecography helps assess pelvic ...

  17. Magnetic Resonance Cholangiopancreatography (MRCP)

    Science.gov (United States)

    ... radio waves and a computer to evaluate the liver, gallbladder, bile ducts, pancreas and pancreatic duct for disease. It is ... of the hepatobiliary and pancreatic systems, including the liver, gallbladder, bile ducts, pancreas and pancreatic duct . Magnetic resonance imaging (MRI) ...

  18. Magnetic resonance angiography

    Science.gov (United States)

    ... Saunders; 2015:chap 17. Litt H, Carpenter JP. Magnetic resonance imaging. In: Cronenwett JL, Johnston KW, eds. Rutherford's Vascular Surgery . 8th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap ...

  19. Nuclear magnetic resonance gyroscope

    International Nuclear Information System (INIS)

    Grover, B.C.

    1984-01-01

    A nuclear magnetic resonance gyro using two nuclear magnetic resonance gases, preferably xenon 129 and xenon 131, together with two alkaline metal vapors, preferably rubidium, potassium or cesium, one of the two alkaline metal vapors being pumped by light which has the wavelength of that alkaline metal vapor, and the other alkaline vapor being illuminated by light which has the wavelength of that other alkaline vapor

  20. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    In a method of imaging a body in which nuclear magnetic resonance is excited in a region including part of the body, and the free induction decay signal is measured, a known quantity of a material of known nuclear magnetic resonance properties, for example a bag of water, is included in the region so as to enhance the measured free induction decay signal. This then reduces the generation of noise during subsequent processing of the signal. (author)

  1. Laser magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Ferrari, C.A.

    1985-01-01

    The technique of laser resonance magnetic resonance allows one to study the high-resolution spectroscopy of transient paramagnetic species, viz, atoms, radicals, and molecular ions. This article is a brief exposition of the method, describing the principles, instrumentation and applicability of the IR and FIR-LMR and shows results of HF + . (Author) [pt

  2. Nuclear Magnetic Resonance Spectroscopy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 1. Nuclear Magnetic Resonance Spectroscopy. Susanta Das. General Article Volume 9 Issue 1 January 2004 pp 34-49. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/009/01/0034-0049. Keywords.

  3. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Magnetic resonance imaging (MRI) is a new and innovative technique that affords anatomic images in multiple planes and that may provide information about tissue characterization. The magnetic resonance images are obtained by placing the patient or the area of interest within a powerful, highly uniform, static magnetic field. Magnetized protons (hydrogen nuclei) within the patient align like small magnets in this field. Radiofrequency pulses are then used to create an oscillating magnetic field perpendicular to the main field. Magnetic resonance images differ from those produced by x-rays: the latter are associated with absorption of x-ray energy while magnetic resonance images are based on proton density and proton relaxation dynamics. Proton characteristics vary according to the tissue under examination and reflect its physical and chemical properties. To resolve issues regarding safety and efficacy, the Warren Grant Magnuson Clinical Center and the Office of Medical Applications of Research of the National Institutes of Health (NIH) convened a consensus conference about MRI Oct 26 through 28, 1987. At the NIH, the Consensus Development Conference brings together investigators in the biomedical sciences, clinical investigators, practicing physicians, and consumer and special interest groups to make a scientific assessment of technologies, including drugs, devices, and procedures, and to seek agreement on their safety and effectiveness

  4. Nuclear magnetic resonance apparatus

    International Nuclear Information System (INIS)

    Lambert, R.

    1991-01-01

    In order to include the effect of a magnetic object in a subject under investigation, Nuclear Magnetic Resonance (NMR) apparatus is operable at more than one radio frequency (RF) frequency. The apparatus allows normal practice as far as obtaining an NMR response or image from a given nuclear species is concerned, but, in addition, interrogates the nuclear spin system at a frequency which is different from the resonance frequency normally used for the given nuclear species, as determined from the applied magnetic field. The magnetic field close to a magnetised or magnetisable object is modified and the given nuclear species gives a response at the different frequency. Thus detection of a signal at the frequency indicates the presence of the chosen nuclei close to the magnetised or magnetisable object. Applications include validation of an object detection or automatic shape inspection system in the presence of magnetic impurities, and the detection of magnetic particles which affect measurement of liquid flow in a pipe. (author)

  5. Diagnostic significance of gadolinium-DTPA (diethylenetriamine penta-acetic acid) enhanced magnetic resonance imaging in thrombolytic treatment for acute myocardial infarction: its potential in assessing reperfusion.

    Science.gov (United States)

    van der Wall, E E; van Dijkman, P R; de Roos, A; Doornbos, J; van der Laarse, A; Manger Cats, V; van Voorthuisen, A E; Matheijssen, N A; Bruschke, A V

    1990-01-01

    The diagnostic value of gadolinium-DTPA (diethylenetriamine penta-acetic acid) enhanced magnetic resonance imaging in patients treated by thrombolysis for acute myocardial infarction was assessed in 27 consecutive patients who had a first acute myocardial infarction (14 anterior, 13 inferior) and who underwent thrombolytic treatment and coronary arteriography within 4 hours of the onset of symptoms. Magnetic resonance imaging was performed 93 hours (range 15-241) after the onset of symptoms. A Philips Gyroscan (0.5 T) was used, and spin echo measurements (echo time 30 ms) were made before and 20 minutes after intravenous injection of 0.1 mmol/kg gadolinium-DTPA. In all patients contrast enhancement of the infarcted areas was seen after Gd-DTPA. The signal intensities of the infarcted and normal values were used to calculate the intensity ratios. Mean (SD) intensity ratios after Gd-DTPA were significantly increased (1.15 (0.17) v 1.52 (0.29). Intensity ratios were higher in the 17 patients who underwent magnetic resonance imaging more than 72 hours after the onset of symptoms than in the 10 who underwent magnetic resonance imaging earlier, the difference being significantly greater after administration of Gd-DTPA (1.38 (0.12) v 1.61 (0.34). When patients were classified according to the site and size of the infarcted areas, or to reperfusion (n = 19) versus non-reperfusion (n = 8), the intensity ratios both before and after Gd-DTPA did not show significant differences. Magnetic resonance imaging with Gd-DTPA improved the identification of acutely infarcted areas, but with current techniques did not identify patients in whom thrombolytic treatment was successful. Images PMID:2310640

  6. Nuclear magnetic resonance scattering

    International Nuclear Information System (INIS)

    Young, I.R.

    1985-01-01

    A nuclear magnetic resonance apparatus is described including a magnet system which is capable of providing a steady magnetic field along an axis, and is constructed so as to define a plurality of regions along the axis in each of which the field is substantially homogeneous so that in each region an imaging operation may be separately carried out. Iron shields increase the field homogeneity. In use, each patient lies on a wheeled trolley which is provided with magnetic field gradient coils and an RF coil system, some of the coils being movable to facilitate positioning of the patient, and there are terminals for connection to a common computing and control facility. (author)

  7. Magnetic resonance annual, 1988

    International Nuclear Information System (INIS)

    Kressel, H.Y.

    1987-01-01

    This book features reviews of high-resolution MRI of the knee, MRI of the normal and ischmeic hip, MRI of the heart, and temporomandibular joint imaging, as well as thorough discussion on artifacts in magnetic resonance imaging. Contributors consider the clinical applications of gadolinium-DTPA in magnetic resonance imaging and the clinical use of partial saturation and saturation recovery sequences. Timely reports assess the current status of rapid MRI and describe a new rapid gated cine MRI technique. Also included is an analysis of cerebrospinal fluid flow effects during MRI of the central nervous system

  8. Advances in magnetic resonance 10

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 10, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters that examine superoperators in magnetic resonance; ultrasonically modulated paramagnetic resonance; and the utility of electron paramagnetic resonance (EPR) and electron-nuclear double-resonance (ENDOR) techniques for studying low-frequency modes of atomic fluctuations and their significance for understanding the mechanism of structural phase transitions in solids.

  9. Diagnostic usefulness of endorectal magnetic resonance imaging with dynamic contrast-enhancement in patients with localized prostate cancer. Mapping studies with biopsy specimens

    International Nuclear Information System (INIS)

    Tanaka, Nobumichi; Samma, Shoji; Joko, Masanori; Akiyama, Tatsuya; Takewa, Megumi; Kitano, Satoru; Okajima, Eigoro

    1999-01-01

    New diagnostic criteria for dynamic magnetic resonance (MR) imaging in prostate cancer are presented. The diagnostic usefulness of endorectal MR imaging with dynamic contrast-enhancement in localized prostate cancer and the validity of these criteria were evaluated. Eighteen untreated patients who were suspected of localized prostate cancer were included in the study. They received endorectal dynamic MR imaging before systematic sextant needle biopsy. First, a mapping study with the findings of MR images and histopathology of biopsy specimens was performed in eight patients out of 18 to compare the difference in T2-weighted images with the endorectal coil and the body coil in the same individuals. Second, another mapping study was performed in all 18 patients by analyzing the findings of endorectal dynamic MR images. For the diagnosis of prostate cancer in MR imaging, we offered diagnostic criteria from our experience in addition to those in plain T2-weighted images from the literature. The overall diagnostic rates of endorectal dynamic MR imaging were 88.9% in accuracy, 100% in sensitivity, and 81.8% in specificity. In the comparison of the endorectal and body coils in T2-weighted images in eight patients, there was no difference in the diagnostic rates except for one more histopathologic false positive portion in endorectal MR imaging. In the second mapping study in 18 patients, the diagnostic rates were 92.6% in accuracy, 88.9% in sensitivity and 93.3% in specificity. Endorectal dynamic imaging raised the diagnostic sensitivity from 77.8 to 88.9%. The data demonstrated the validity of this diagnostic criteria and the diagnostic usefulness of endorectal dynamic MR imaging in localized prostate cancer. (author)

  10. Imaging by magnetic resonance

    International Nuclear Information System (INIS)

    Duroure, J.F.; Serpolay, H.; Vallens, D.

    1995-01-01

    Here are described the advanced technology for nuclear magnetic resonance imaging: reduction of acquisition times, and rebuilding times, images quality improvement. The tendency is to open the machines at low and middle field, on a market being at 10% of NMR I sales, with economical, scientifical and ergonomic reasons broadly developed by constructors

  11. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  12. Nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Rueterjans, H.

    1987-01-01

    Contributions by various authors who are working in the field of NMR imaging present the current status and the perspectives of in-vivo nuclear magnetic resonance spectroscopy, explaining not only the scientific and medical aspects, but also technical and physical principles as well as questions concerning practical organisation and training, and points of main interest for further research activities. (orig./TRV) [de

  13. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    1983-06-01

    This report summarises the aspects of nuclear magnetic resonance imaging (NMRI) considered by the National Health Technology Advisory Panel and makes recommendations on its introduction in Australia with particular regard to the need for thorough evaluation of its cost effectiveness. Topics covered are: principles of the technique, equipment required, installation, costs, reliability, performance parameters, clinical indications, training and staff requirements, and safety considerations

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  15. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining ...

  16. Magnetic Resonance Imaging of Stroke

    NARCIS (Netherlands)

    Bouts, Mark. J. R. J.; Wu, O.; Dijkhuizen, R. M.

    2017-01-01

    Magnetic resonance imaging (MRI) provides a powerful (neuro)imaging modality for the diagnosis and outcome prediction after (acute) stroke. Since MRI allows noninvasive, longitudinal, and three-dimensional assessment of vessel occlusion (with magnetic resonance angiography (MRA)), tissue injury

  17. Magnetic resonance of phase transitions

    CERN Document Server

    Owens, Frank J; Farach, Horacio A

    1979-01-01

    Magnetic Resonance of Phase Transitions shows how the effects of phase transitions are manifested in the magnetic resonance data. The book discusses the basic concepts of structural phase and magnetic resonance; various types of magnetic resonances and their underlying principles; and the radiofrequency methods of nuclear magnetic resonance. The text also describes quadrupole methods; the microwave technique of electron spin resonance; and the Mössbauer effect. Phase transitions in various systems such as fluids, liquid crystals, and crystals, including paramagnets and ferroelectrics, are also

  18. MAST magnetic diagnostics

    Science.gov (United States)

    Edlington, T.; Martin, R.; Pinfold, T.

    2001-01-01

    The mega-ampere spherical tokamak (MAST) experiment is a new, large, low aspect ratio device (R=0.7-0.8 m, a=0.5-0.65 m, maximum BT˜0.63 T at R=0.7 m) operating its first experimental physics campaign. Designed to study a wide variety of plasma shapes with up to 2 MA of plasma current with an aspect ratio down to 1.3, the poloidal field (PF) coils used for plasma formation, equilibrium and shaping are inside the main vacuum vessel. For plasma control and to investigate a wide range of plasma phenomena, an extensive set of magnetic diagnostics have been installed inside the vacuum vessel. More than 600 vacuum compatible, bakeable diagnostic coils are configured in a number of discrete arrays close to the plasma edge with about half the coils installed behind the graphite armour tiles covering the center column. The coil arrays measure the toroidal and poloidal variation in the equilibrium field and its high frequency fluctuating components. Internal coils also measure currents in the PF coils, plasma current, stored energy and induced currents in the mechanical support structures of the coils and graphite armour tiles. The latter measurements are particularly important when halo currents are induced following a plasma termination, for example, when the plasma becomes vertically unstable. The article describes the MAST magnetic diagnostic coil set and their calibration. The way in which coil signals are used to control the plasma equilibrium is described and data from the first MAST experimental campaign presented. These coil data are used as input to the code EFIT [L. Lao et al., Nucl. Fusion 25, 1611 (1985)], for measurement of halo currents in the vacuum vessel structure and for measurements of the structure of magnetic field fluctuations near the plasma edge.

  19. Low field-low cost: Can low-field magnetic resonance systems replace high-field magnetic resonance systems in the diagnostic assessment of multiple sclerosis patients?

    International Nuclear Information System (INIS)

    Ertl-Wagner, B.B.; Reith, W.; Sartor, K.

    2001-01-01

    As low-field MR imaging is becoming a widely used imaging technique, we aimed at a prospective assessment of differences in imaging quality between low- and high-field MR imaging in multiple sclerosis patients possibly interfering with diagnostic or therapeutic decision making. Twenty patients with clinically proven multiple sclerosis were examined with optimized imaging protocols in a 1.5- and a 0.23-T MR scanner within 48 h. Images were assessed independently by two neuroradiologists. No statistically significant interrater discrepancies were observed. A significantly lower number of white matter lesions could be identified in low-field MR imaging both on T1- and on T2-weighted images (T2: high field 700, low field 481; T1: high field 253, low field 177). A total of 114 enhancing lesions were discerned in the high-field MR imaging as opposed to 45 enhancing lesions in low-field MR imaging. Blood-brain barrier disruption was identified in 11 of 20 patients in the high-field MR imaging, but only in 4 of 20 patients in low-field MR imaging. Since a significantly lower lesion load is identified in low-field MR imaging than in high-field MR imaging, and blood-brain barrier disruption is frequently missed, caution must be exercised in interpreting a normal low-field MR imaging scan in a patient with clinical signs of multiple sclerosis and in interpreting a scan without enhancing lesions in a patient with known multiple sclerosis and clinical signs of exacerbation. (orig.)

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging ( ... the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  5. Magnetic resonance imaging in psychiatry

    International Nuclear Information System (INIS)

    Mann, K.

    1993-01-01

    Diagnosis and research in psychiatry are increasingly availing themselves of magnetic resonance imaging (MRI). In comparison to computed tomography (CT), this offers the combined benefits of no exposure to radiation, high resolution, artefact-free display of structures near bone, and a sharp contrast between the grey and white brain matter, with freedom to select the section. With the exception of very anxious patients, MRI will gradually replace CT scans for a wide range of differential diagnostic investigations. Its superiority in systematic studies of psychiatric patients with discrete cerebral parenchyma lesions is already considered proven. This is illustrated on the basis of research into schizophrenia and alcoholism. (orig.) [de

  6. Musculoskeletal applications of magnetic resonance imaging: Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Harms, S.E.; Fisher, C.F.; Fulmer, J.M.

    1989-01-01

    Magnetic resonance imaging provides superior contrast, resolution, and multiplanar imaging capability, allowing excellent definition of soft-tissue and bone marrow abnormalities. For these reasons, magnetic resonance imaging has become a major diagnostic imaging method for the evaluation of many musculoskeletal disorders. The applications of magnetic resonance imaging for musculoskeletal diagnosis are summarized and examples of common clinical situations are given. General guidelines are suggested for the musculoskeletal applications of magnetic resonance imaging

  7. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sigal, R.

    1988-01-01

    This book is an introduction to magnetic resonance imaging (MRI). The basic principles for the interpretation of MR images are developed. The book is divided into five chapters: introduction, tissue, parameters, acquisition parameters, contribution to diagnosis, and practical management of an MR examination. Eight exercises allow the reader to test the knowledge he has acquired. Signal localization and MR artefacts are reviewed in an appendix

  8. Magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Takavar A

    1993-04-01

    Full Text Available Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I, a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D. factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  9. Magnetic resonance imaging (MRI)

    OpenAIRE

    Takavar A

    1993-01-01

    Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I), a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D.) factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  10. The diagnostic performance of magnetic resonance spectroscopy in differentiating high-from low-grade gliomas: A systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Wang, Qun; Zhang, JiaShu; Wu, Chen; Li, FangYe; Chen, XiaoLei; Xu, BaiNan; Zhang, Hui; Zhu, WeiJie

    2016-01-01

    Magnetic resonance spectroscopy (MRS) is a powerful tool for preoperative grading of gliomas. We performed a meta-analysis to evaluate the diagnostic performance of MRS in differentiating high-grade gliomas (HGGs) from low-grade gliomas (LGGs). PubMed and Embase databases were systematically searched for relevant studies of glioma grading assessed by MRS through 27 March 2015. Based on the data from eligible studies, pooled sensitivity, specificity, diagnostic odds ratio and areas under summary receiver operating characteristic curve (SROC) of different metabolite ratios were obtained. Thirty articles comprising a total sample size of 1228 patients were included in our meta-analysis. Quantitative synthesis of studies showed that the pooled sensitivity/specificity of Cho/Cr, Cho/NAA and NAA/Cr ratios was 0.75/0.60, 0.80/0.76 and 0.71/0.70, respectively. The area under the curve (AUC) of the SROC was 0.83, 0.87 and 0.78, respectively. MRS demonstrated moderate diagnostic performance in distinguishing HGGs from LGGs using tumoural metabolite ratios including Cho/Cr, Cho/NAA and NAA/Cr. Although there was no significant difference in AUC between Cho/Cr and Cho/NAA groups, Cho/NAA ratio showed higher sensitivity and specificity than Cho/Cr ratio and NAA/Cr ratio. We suggest that MRS should combine other advanced imaging techniques to improve diagnostic accuracy in differentiating HGGs from LGGs. (orig.)

  11. Non-invasive diagnostic workup of patients with suspected stable angina by combined computed tomography coronary angiography and magnetic resonance perfusion imaging

    International Nuclear Information System (INIS)

    Kirschbaum, S.W.; Nieman, K.; Springeling, T.

    2011-01-01

    The background of this study was to evaluate additional adenosine magnetic resonance perfusion (MRP) imaging in the diagnostic workup of patients with suspected stable angina with computed tomography coronary angiography (CTCA) as first-line diagnostic modality. Two hundred and thirty symptomatic patients (male, 52%; age, 56 year) with suspected stable angina underwent CTCA. In patients with a stenosis of >50% as visually assessed, MRP was performed and the quantitative myocardial perfusion reserve index (MPRI) was calculated. Coronary flow reserve (CFR) using invasive coronary flow measurements served as the standard of reference. CTCA showed non-significant coronary artery disease (CAD) in 151/230 (66%) patients and significant CAD in 79/230 patients (34%), of whom 50 subsequently underwent MRP and CFR. MRP showed reduced perfusion in 32 patients (64%), which was confirmed by CFR in 27 (84%). All 18 cases of normal MRP (36%) were confirmed by CFR. The positive likelihood ratio of MRP for the presence of functional significant disease in patients with a lesion on CTCA was 4.49 (95% confidence interval [CI] 2.12-9.99). The negative likelihood ratio was 0.05 (95% CI 0.01-0.34). CTCA as first-line diagnostic modality excluded coronary artery disease in a high percentage of patients referred for diagnostic workup of suspected stable angina. MRP made a significant contribution to the detection of functional significant lesions in patients with a positive CTCA. (author)

  12. Comparison of the diagnostic performance of digital breast tomosynthesis and magnetic resonance imaging added to digital mammography in women with known breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Hwa; Chang, Jung Min; Moon, Woo Kyung [Seoul National University Hospital, Department of Radiology, 101 Daehangno, Jongno-gu, Seoul (Korea, Republic of); Moon, Hyeong-Gon [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of); Yi, Ann [Seoul National University Hospital, Department of Radiology, Gangnan Healthcare Center, Seoul (Korea, Republic of); Koo, Hye Ryoung [Hanyang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Gweon, Hye Mi [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2016-06-15

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to mammography in women with known breast cancers. Three radiologists independently reviewed image sets of 172 patients with 184 cancers; mammography alone, DBT plus mammography and MRI plus mammography, and scored for cancer probability using the Breast Imaging Reporting and Data System (BI-RADS). Jack-knife alternative free-response receiver-operating characteristic (JAFROC), which allows diagnostic performance estimation using single lesion as a statistical unit in a cancer-only population, was used. Sensitivity and positive predictive value (PPV) were compared using the McNemar and Fisher-exact tests. The JAFROC figures of merit (FOMs) was lower in DBT plus mammography (0.937) than MRI plus mammography (0.978, P = 0.0006) but higher than mammography alone (0.900, P = 0.0013). The sensitivity was lower in DBT plus mammography (88.2 %) than MRI plus mammography (97.8 %) but higher than mammography alone (78.3 %, both P < 0.0001). The PPV was significantly higher in DBT plus mammography (93.3 %) than MRI plus mammography (89.6 %, P = 0.0282). DBT provided lower diagnostic performance than MRI as an adjunctive imaging to mammography. However, DBT had higher diagnostic performance than mammography and higher PPV than MRI. (orig.)

  13. Comparison of the diagnostic performance of digital breast tomosynthesis and magnetic resonance imaging added to digital mammography in women with known breast cancers

    International Nuclear Information System (INIS)

    Kim, Won Hwa; Chang, Jung Min; Moon, Woo Kyung; Moon, Hyeong-Gon; Yi, Ann; Koo, Hye Ryoung; Gweon, Hye Mi

    2016-01-01

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to mammography in women with known breast cancers. Three radiologists independently reviewed image sets of 172 patients with 184 cancers; mammography alone, DBT plus mammography and MRI plus mammography, and scored for cancer probability using the Breast Imaging Reporting and Data System (BI-RADS). Jack-knife alternative free-response receiver-operating characteristic (JAFROC), which allows diagnostic performance estimation using single lesion as a statistical unit in a cancer-only population, was used. Sensitivity and positive predictive value (PPV) were compared using the McNemar and Fisher-exact tests. The JAFROC figures of merit (FOMs) was lower in DBT plus mammography (0.937) than MRI plus mammography (0.978, P = 0.0006) but higher than mammography alone (0.900, P = 0.0013). The sensitivity was lower in DBT plus mammography (88.2 %) than MRI plus mammography (97.8 %) but higher than mammography alone (78.3 %, both P < 0.0001). The PPV was significantly higher in DBT plus mammography (93.3 %) than MRI plus mammography (89.6 %, P = 0.0282). DBT provided lower diagnostic performance than MRI as an adjunctive imaging to mammography. However, DBT had higher diagnostic performance than mammography and higher PPV than MRI. (orig.)

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed ... problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it may cause some ...

  15. Diagnostic accuracy of computer tomography angiography and magnetic resonance angiography in the stenosis detection of autologuous hemodialysis access: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Bin Li

    Full Text Available PURPOSE: To compare the diagnostic performances of computer tomography angiography (CTA and magnetic resonance angiography (MRA for detection and assessment of stenosis in patients with autologuous hemodialysis access. MATERIALS AND METHODS: Search of PubMed, MEDLINE, EMBASE and Cochrane Library database from January 1984 to May 2013 for studies comparing CTA or MRA with DSA or surgery for autologuous hemodialysis access. Eligible studies were in English language, aimed to detect more than 50% stenosis or occlusion of autologuous vascular access in hemodialysis patients with CTA and MRA technology and provided sufficient data about diagnosis performance. Methodological quality was assessed by the Quality Assessment of Diagnostic Studies (QUADAS instrument. Sensitivities (SEN, specificities (SPE, positive likelihood ratio (PLR, negative likelihood values (NLR, diagnostic odds ratio (DOR and areas under the receiver operator characteristic curve (AUC were pooled statistically. Potential threshold effect, heterogeneity and publication bias was evaluated. The clinical utility of CTA and MRA in detection of stenosis was also investigated. RESULT: Sixteen eligible studies were included, with a total of 500 patients. Both CTA and MRA were accurate modality (sensitivity, 96.2% and 95.4%, respectively; specificity, 97.1 and 96.1%, respectively; DOR [diagnostic odds ratio], 393.69 and 211.47, respectively for hemodialysis vascular access. No significant difference was detected between the diagnostic performance of CTA (AUC, 0.988 and MRA (AUC, 0.982. Meta-regression analyses and subgroup analyses revealed no statistical difference. The Deek's funnel plots suggested a publication bias. CONCLUSION: Diagnostic performance of CTA and MRA for detecting stenosis of hemodialysis vascular access had no statistical difference. Both techniques may function as an alternative or an important complement to conventional digital subtraction angiography (DSA and may be

  16. Introduction lecture to magnetic resonance

    International Nuclear Information System (INIS)

    Conard, J.

    1980-01-01

    This lecture deals with all that is common either to electron paramagnetic resonance (E.P.R.) or to nuclear magnetic resonance (N.M.R.). It will present, in an as elementary form as possible, the main concepts used in magnetic resonance emphasizing some aspects, specific for interface science. (orig./BHO)

  17. Magnetic resonance imaging as a diagnostic tool in case of ovarian masses in girls and young women.

    Science.gov (United States)

    Bekiesińska-Figatowska, Monika; Jurkiewicz, Elzbieta; Iwanowska, Beata; Uliasz, Maria; Romaniuk-Doroszewska, Anna; Bragoszewska, Hanna; Ceran, Alicja; Olszewski, Andrzej

    2007-05-01

    Gynecological examination and transvaginal ultrasound are difficult or impossible in girls and young women who have not started their sexual life. CT is not a method of choice in this age group because of the ionizing radiation and iodine-containing contrast media. MRI is chosen then. Pelvic MRI was performed in 15 patients aged 9-19 years with suspected ovarian mass after they had had unclear gynecological and sonographic examinations. 1.5 T MRI systems were used. SE,T(F)SE and SPIR sequences were applied in T1- and T2-weighted images in three planes. Contrast media were administered in 7 patients. In a group of 3 girls with acute abdominal pain, polycystic ovaries, ovarian hemorrhagic cyst, and fibroma of the ovary were diagnosed. In a group of 11 patients with chronic abdominal pain, dermoid cysts of the ovaries were found in 7 cases, in one bilateral and accompanied by ectopic kidney. In 2 patients, serous cysts were diagnosed. In 2 cases an ovarian origin of the mass was excluded: multilocular cystic lesion in the presacral region and a hydatid mole were revealed. A neoplastic ovarian mass was diagnosed in a girl with increasing circumference of the abdomen. The accuracy of MRI in localizing lesions was 100%. Its accuracy in precisely characterizing lesions was 83.3%. Magnetic resonance imaging, with its noninvasiveness, high spatial resolution, and tissue specificity, is a method of choice in the diagnosis or exclusion of ovarian pathology in children and adolescents.

  18. Myxofibrosarcoma: prevalence and diagnostic value of the ''tail sign'' on magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lefkowitz, Robert A.; Landa, Jonathan; Hwang, Sinchun; Panicek, David M. [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Medical College of Cornell University, New York, NY (United States); Zabor, Emily C.; Moskowitz, Chaya S. [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Agaram, Narasimhan P. [Memorial Sloan-Kettering Cancer Center, Department of Pathology, New York, NY (United States)

    2013-06-15

    Myxofibrosarcoma frequently shows curvilinear extensions of high T2 signal that also enhance on magnetic resonance imaging; these ''tails'' represent fascial extension of tumor at histopathological examination. This study was performed to determine whether the tail sign is helpful in distinguishing myxofibrosarcoma from other myxoid-containing neoplasms. The study group consisted of 44 patients with pathologically proven myxofibrosarcoma; the control group consisted of 52 patients with a variety of other myxoid-predominant tumors. Three musculoskeletal radiologists independently evaluated T2-weighted (and/or short-tau inversion recovery) and post-contrast MR images for the presence of one or more enhancing, high-signal intensity, curvilinear projections from the primary mass. Sensitivity and specificity for the diagnosis of myxofibrosarcoma were calculated for each reader. Interobserver variability was assessed with kappa statistic and percentage agreement. A tail sign was deemed present in 28, 30, and 34 cases of myxofibrosarcoma and in 11, 9, and 5 of the controls for the three readers respectively, yielding a sensitivity of 64-77 % and a specificity of 79-90 %. The interobserver agreement was moderate-to-substantial (kappa = 0.626). The tail sign at MRI is a moderately specific and sensitive sign for the diagnosis of myxofibrosarcoma relative to other myxoid-containing tumors. (orig.)

  19. Clinical features of congenital cystic disease of the mediastinum. Diagnostic usefulness of computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bando, Masashi; Ishii, Yoshiki; Sugiyama, Yukihiko; Furuse, Makoto; Murayama, Fumio; Sohara, Yasunori

    2000-01-01

    We describe 18 cases of congenital mediastinal cysts, including 4 bronchogenic cysts, 5 pericardial cysts, and 9 thymic cysts. Fifteen of the 18 patients (62.5%) were asymptomatic, and the cysts were found incidentally on a chest radiograph conducted as a part of a physical screening. In 2 of the 4 cases of bronchogenic cysts, the cystic lesions were located in the posterior mediastinum and in the cephalad recess of the azgos vein (CRAzV). In 3 of the 5 cases of pericardial cysts, the lesions were located in the right cardio-phrenic region. In the remaining 2 cases, the cysts were located in the CRAzV and in the posterior mediastinum. Seventeen patients who had histologically proven mediastinal cysts were investigated by magnetic resonance (MR) imaging. In all 3 cases of bronchogenic cysts, MR signals of the cysts were of higher intensity than those of muscle on T1-weighted images. Neither the pericardial cysts nor the thymic cysts showed high signal intensity on T1-weighted images. Macroscopically, the intracystic fluids in all of the bronchogenic cysts contained viscid mucus that probably caused high signal intensities on the T1-weighted images. MR imaging is not only useful in revealing the location of mediastinal cysts, but also in the differential diagnosis of congenital mediastinal cysts. (author)

  20. Diagnostic value of combined magnetic resonance imaging examination of brachial plexus and electrophysiological studies in multifocal motor neuropathy

    Directory of Open Access Journals (Sweden)

    Basta Ivana

    2014-01-01

    Full Text Available Background/Aim. Multifocal motor neuropathy (MMN is an immune-mediated disorder characterized by slowly progressive asymetrical weakness of limbs without sensory loss. The objective of this study was to investigate the involvement of brachial plexus using combined cervical magnetic stimulation and magnetic resonance imaging (MRI of plexus brachialis in patients with MMN. We payed special attention to the nerve roots forming nerves inervating weak muscles, but without detectable conduction block (CB using conventional nerve conduction studies. Methods. Nine patients with proven MMN were included in the study. In all of them MRI of the cervical spine and brachial plexus was performed using a Siemens Avanto 1.5 T unit, applying T1 and turbo spinecho T1 sequence, axial turbo spin-echo T2 sequence and a coronal fat-saturated turbo spin-echo T2 sequence. Results. In all the patients severe asymmetric distal weakness of muscles inervated by radial, ulnar, median and peroneal nerves was observed and the most striking presentation was bilateral wrist and finger drop. Three of them had additional proximal weakness of muscles inervated by axillar and femoral nerves. The majority of the patients had slightly increased cerebrospinal fluid (CSF protein content. Six of the patients had positive serum polyclonal IgM anti-GM1 antibodies. Electromyoneurography (EMG showed neurogenic changes, the most severe in distal muscles inervated by radial nerves. All the patients had persistent partial CBs outside the usual sites of nerve compression in radial, ulnar, median and peroneal nerves. In three of the patients cervical magnetic stimulation suggested proximal CBs between cervical root emergence and Erb’s point (prolonged motor root conduction time. In all the patients T2-weighted MRI revealed increased signal intensity in at least one cervical root, truncus or fasciculus of brachial plexus. Conclusion. We found clinical correlation between muscle weakness

  1. Magnetic resonance imaging-detected extramural venous invasion in rectal cancer before and after preoperative chemoradiotherapy. Diagnostic performance and prognostic significance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun [Chung-Ang University Hospital, Department of Radiology, Seoul (Korea, Republic of); Chung-Ang University, College of Medicine and Graduate School of Medicine, Seoul (Korea, Republic of); National Cancer Centre, Department of Radiology, Goyang-si, Gyeonggi-do (Korea, Republic of); Kim, Min Ju; Hur, Bo Yun [National Cancer Centre, Department of Radiology, Goyang-si, Gyeonggi-do (Korea, Republic of); Park, Sung Chan; Hyun, Jong Hee; Chang, Hee Jin; Baek, Ji Yeon; Kim, Dae Yong; Oh, Jae Hwan [National Cancer Centre, Centre for Colorectal Cancer, Goyang, Gyeonggi-do (Korea, Republic of); Kim, Sun Young [National Cancer Centre, Centre for Colorectal Cancer, Goyang, Gyeonggi-do (Korea, Republic of); University of Ulsan College of Medicine, Department of Oncology, Asan Medical Centre, Seoul (Korea, Republic of)

    2018-02-15

    We evaluated the diagnostic performance of magnetic resonance imaging (MRI) in terms of identifying extramural venous invasion (EMVI) in rectal cancer patients with preoperative chemoradiotherapy (CRT) and its prognostic significance. During 2008-2010, 200 patients underwent surgery following preoperative CRT for rectal cancer. Two radiologists independently reviewed all pre- and post-CRT MRI retrospectively. We investigated diagnostic performance of pre-CRT MR-EMVI (MR-EMVI) and post-CRT MR-EMVI (yMR-EMVI), based on pathological EMVI as the standard of reference. We assessed correlation between MRI findings and patients' prognosis, such as disease-free survival (DFS) and overall survival (OS). Additionally, subgroup analysis in MR- or yMR-EMVI-positive patients was performed to confirm the significance of the severity of EMVI in MRI on patient's prognosis. The sensitivity and specificity of yMR-EMVI were 76.19% and 79.75% (area under the curve: 0.830), respectively. In univariate analysis, yMR-EMVI was the only significant MRI factor in DFS (P = 0.027). The mean DFS for yMR-EMVI (+) patients was significantly less than for yMR-EMVI (-) patients: 57.56 months versus 72.46 months. yMR-EMVI demonstrated good diagnostic performance. yMR-EMVI was the only significant EMVI-related MRI factor that correlated with patients' DFS in univariate analysis; however, it was not significant in multivariate analysis. (orig.)

  2. Cardiac magnetic resonance imaging after ventricular tachyarrhythmias increases diagnostic precision and reduces the need for family screening for inherited cardiac disease

    DEFF Research Database (Denmark)

    Marstrand, Peter; Axelsson, Anna; Thune, Jens Jakob

    2016-01-01

    -CAG) (81%), exercise stress test (47%), late potentials (54%), electrophysiological study (44%), pharmacological provocation (44%), and/or myocardial biopsy (16%). Family screening was indicated for 53 probands (67%) prior to CMR. After full workup, only 43 cases (54%) warranted evaluation of relatives (19......AIMS: Guidelines recommend evaluation of family members of sudden cardiac death victims. However, initiation of cascade screening in families with uncertain diagnoses is not cost-effective and may cause unnecessary concern. For these reasons, we set out to assess to what extent cardiac magnetic...... resonance imaging (CMR) would increase the diagnostic precision and thereby possibly change the indication for family screening in patients with ventricular tachyarrhythmias. METHODS AND RESULTS: We retrospectively collected data from 79 patients hospitalized with aborted cardiac arrest (resuscitated from...

  3. Diagnostic accuracy of cardiovascular magnetic resonance imaging of right ventricular morphology and function in the assessment of suspected pulmonary hypertension results from the ASPIRE registry

    Directory of Open Access Journals (Sweden)

    Swift Andrew J

    2012-06-01

    Full Text Available Abstract Background Cardiovascular Magnetic Resonance (CMR imaging is accurate and reproducible for the assessment of right ventricular (RV morphology and function. However, the diagnostic accuracy of CMR derived RV measurements for the detection of pulmonary hypertension (PH in the assessment of patients with suspected PH in the clinic setting is not well described. Methods We retrospectively studied 233 consecutive treatment naïve patients with suspected PH including 39 patients with no PH who underwent CMR and right heart catheterisation (RHC within 48hours. The diagnostic accuracy of multiple CMR measurements for the detection of mPAP ≥ 25 mmHg was assessed using Fisher’s exact test and receiver operating characteristic (ROC analysis. Results Ventricular mass index (VMI was the CMR measurement with the strongest correlation with mPAP (r = 0.78 and the highest diagnostic accuracy for the detection of PH (area under the ROC curve of 0.91 compared to an ROC of 0.88 for echocardiography calculated mPAP. Late gadolinium enhancement, VMI ≥ 0.4, retrograde flow ≥ 0.3 L/min/m2 and PA relative area change ≤ 15% predicted the presence of PH with a high degree of diagnostic certainty with a positive predictive value of 98%, 97%, 95% and 94% respectively. No single CMR parameter could confidently exclude the presence of PH. Conclusion CMR is a useful alternative to echocardiography in the evaluation of suspected PH. This study supports a role for the routine measurement of ventricular mass index, late gadolinium enhancement and the use of phase contrast imaging in addition to right heart functional indices in patients undergoing diagnostic CMR evaluation for suspected pulmonary hypertension.

  4. Breast-specific gamma camera imaging with 99mTc-MIBI has better diagnostic performance than magnetic resonance imaging in breast cancer patients: A meta-analysis.

    Science.gov (United States)

    Zhang, Aimi; Li, Panli; Liu, Qiufang; Song, Shaoli

    2017-01-01

    This study aimed to evaluate the diagnostic role of breast-specific gamma camera imaging (BSGI) with technetium-99m-methoxy isobutyl isonitrile ( 99m Tc-MIBI) and magnetic resonance imaging (MRI) in patients with breast cancer through a meta-analysis. Three reviewers searched articles published in medical journals before June 2016 in MEDLINE, EMBASE and Springer Databases; the references listed in original articles were also retrieved. We used the quality assessment of diagnostic accuracy studies (QUADAS) tool to assess the quality of the included studies. Heterogeneity, pooled sensitivity and specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC) curves were calculated by Meta-DiSc software to estimate the diagnostic performance of BSGI and MRI. Ten studies with 517 patients were included after meeting the inclusion criteria. We did a subgroup analysis of the same data type. The pooled sensitivities of BSGI and MRI were: 0.84 (95% CI, 0.79-0.88) and 0.89 (95% CI, 0.84-0.92) respectively, and the pooled specificities of BSGI and MRI were: 0.82 (95% CI, 0.74-0.88) and 0.39 (95% CI, 0.30-0.49) respectively. The areas under the SROC curve of BSGI and MRI were 0.93 and 0.72 respectively. The results of our meta-analysis indicated that compared with MRI, BSGI has similar sensitivity, higher specificity, better diagnostic performance, and can be widely used in clinical practice.

  5. Advanced Nuclear Magnetic Resonance

    OpenAIRE

    Alonso, Diego A.

    2014-01-01

    Transparencias en inglés de la asignatura "Resonancia Magnética Nuclear Avanzada" (Advanced Nuclear Magnetic Resonance) (36643) que se imparte en el Máster de Química Médica como asignatura optativa de 3 créditos ECTS. En esta asignatura se completa el estudio iniciado en la asignatura de quinto curso de la licenciatura en Química "Determinación estructural" (7448) y en la del Grado de Química de tercer curso "Determinación estructural de los compuestos orgánicos" (26030) en lo referente a té...

  6. Cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Elster, A.D.

    1988-01-01

    Cranial Magnetic Resonance Imaging is comprehensive, well structured, and well written. The material is current and well referenced. The illustrations are good and complement the text well. The overall quality of publication is above average. The greatest attribute of the book is its readability. The author demonstrates ample skill in making complex subjects, such as MR physics and imaging of cerebral hemorrhage, easy to understand. The book closes with a detailed atlas on the anatomic appearance of the brain on MR images in the axial, coronal, and sagittal planes

  7. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  8. [Magnetic resonance imaging as a prenatal diagnostic tool supplementary to ultrasound in diagnosing fetal and gestational abnormalities].

    Science.gov (United States)

    Porat, Shay; Agid, Ronit; Elchalal, Uriel; Ezra, Yossi; Gomori, J Moshe; Nadjari, Michelle

    2002-04-01

    The use of Magnetic Resonance Imaging (MRI) as a prenatal and gestational imaging modality supplementary to ultrasound has become widespread with the advent of rapid MR sequences in the last few years. These sequences allow acquisition of high-resolution images of the fetus in a single breath-holding period of the mother, with minimal fetal motion artifacts. We describe our experience with this modality in the diagnosis of prenatal and gestational abnormalities. The study population consisted of 39 pregnant women who had a total of 40 MRI examinations from 7/1998 to 7/2000. The indication for all examinations was a suspected fetal or gestational abnormality as suggested by ultrasound scan, laboratory tests or by family history. In 31 cases (77.5%) a correlation was found between the ultrasound findings and the MR imaging, of which in 6 cases (15%) the MRI added new valuable information. In 9 cases (22.5%) the MRI ruled out findings suspected by ultrasound. The prenatal findings were compared with postnatal clinical follow-up, imaging or pathology report in 26 cases (66.6%). In two cases the clinical outcome and postnatal imaging were discordant with the prenatal imaging findings in ultrasound and MRI. Although not proven, MRI is considered safe during pregnancy because it does not use ionizing radiation. It depicts fetal anatomy and pathology well. Also uterine, placental and other maternal structures are well demonstrated. This tool is useful in cases in which there is a suspicion of a malformed fetus or abnormal placenta by an ultrasound examination or in cases in which an ultrasound examination is limited by technical factors. MRI was found to help parents and doctors decide about the fate of a suspected abnormal pregnancy by adding valuable information supplemental to ultrasound examination.

  9. Imaging diagnostics in ovarian cancer: magnetic resonance imaging and a scoring system guiding choice of primary treatment.

    Science.gov (United States)

    Kasper, Sigrid M; Dueholm, Margit; Marinovskij, Edvard; Blaakær, Jan

    2017-03-01

    To analyze the ability of magnetic resonance imaging (MRI) and systematic evaluation at surgery to predict optimal cytoreduction in primary advanced ovarian cancer and to develop a preoperative scoring system for cancer staging. Preoperative MRI and standard laparotomy were performed in 99 women with either ovarian or primary peritoneal cancer. Using univariate and multivariate logistic regression analysis of a systematic description of the tumor in nine abdominal compartments obtained by MRI and during surgery plus clinical parameters, a scoring system was designed that predicted non-optimal cytoreduction. Non-optimal cytoreduction at operation was predicted by the following: (A) presence of comorbidities group 3 or 4 (ASA); (B) tumor presence in multiple numbers of different compartments, and (C) numbers of specified sites of organ involvement. The score includes: number of compartments involved (1-9 points), >1 subdiaphragmal location with presence of tumor (1 point); deep organ involvement of liver (1 point), porta hepatis (1 point), spleen (1 point), mesentery/vessel (1 point), cecum/ileocecal (1 point), rectum/vessels (1 point): ASA groups 3 and 4 (2 points). Use of the scoring system based on operative findings gave an area under the curve (AUC) of 91% (85-98%) for patients in whom optimal cytoreduction could not be achieved. The score AUC obtained by MRI was 84% (76-92%), and 43% of non-optimal cytoreduction patients were identified, with only 8% of potentially operable patients being falsely evaluated as suitable for non-optimal cytoreduction at the most optimal cut-off value. Tumor in individual locations did not predict operability. This systematic scoring system based on operative findings and MRI may predict non-optimal cytoreduction. MRI is able to assess ovarian cancer with peritoneal carcinomatosis with satisfactory concordance with laparotomic findings. This scoring system could be useful as a clinical guideline and should be evaluated and

  10. Advances in magnetic resonance 11

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 11, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters and begins with a discussion of the principles and applications of dynamic nuclear polarization, with emphasis on molecular motions and collisions, intermolecular couplings, and chemical interactions. Subsequent chapters focus on the assessment of a proposed broadband decoupling method and studies of time-domain (or Fourier transform) multiple-quantum nuclear magnetic resonance.

  11. Magnetic resonance imaging in cardiovascular disease

    International Nuclear Information System (INIS)

    Eckel, C.G.; Mettler, F.A. Jr.; Wicks, J.D.; Stevens, G.F.

    1986-01-01

    How does magnetic resonance imaging (MRI) currently contribute in the evaluation of patients with suspected heart disease? What role will MRI play in the future in evaluation of cardiovascular disease? To understand better where MRI fits into the diagnostic algorithm of cardiovascular disease the authors first consider the characteristics that they would like to see in the ideal diagnostic test and then survey the available cardiac diagnostic tests to note the characteristics that limit or recommend a test. In the final analysis, the justification for expensive diagnostic tests such as MRI must be an overall improvement in survival or quality of life in those patients treated after diagnosis

  12. Nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Rabenstein, D.L.; Guo, W.

    1988-01-01

    Nuclear magnetic resonance (NMR) spectroscopy is one of the most widely used instrumental methods, with applications ranging from the characterization of pure compounds by high-resolution NMR to the diagnosis of disease by magnetic resonance imaging (MRI). To give some idea of the wide-spread use of NMR, a computer search for the period 1985-1987 turned up over 500 books and review articles and over 7000 literature citations, not including papers in which NMR was used together with other spectroscopic methods for the routine identification of organic compounds. Consequently, they have by necessity been somewhat selective in the topics they have chosen to cover and in the articles they have cited. In this review, which covers the published literature for the approximate period Sept 1985-Aug 1987, they have focused on new developments and applications of interest to the chemist. First they review recent developments in instrumentation and techniques. Although there have not been any major break-throughs in NMR instrumentation during the past two years, significant refinements have been reported which optimize instrumentation for the demanding multiple pulse experiments in routine use today. Next they review new developments in methods for processing NMR data, followed by reviews of one-dimensional and two-dimensional NMR experiments

  13. Advances in magnetic resonance 6

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 6 focuses on the theoretical and practical aspects of applying magnetic resonance methods to various problems in physical chemistry, emphasizing the different aspects of the exegesis of these problems. This book discusses the gas phase magnetic resonance of electronically excited molecules; techniques for observing excited electronic states; NMR studies in liquids at high pressure; and effect of pressure on self-diffusion in liquids. The nuclear magnetic resonance investigations of organic free radicals; measurement of proton coupling constants by NMR; an

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... immediately after the exam. A few patients experience side effects from the contrast material, including nausea and local ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  17. Diagnostic Value of Multislice Computed Tomography and Magnetic Resonance Imaging in the Diagnosis of Retroperitoneal Spread of Testicular Cancer: A Literature Review

    International Nuclear Information System (INIS)

    Hansen, J.; Jurik, A.G.

    2009-01-01

    Testicular cancer is the most frequent malignant disorder in men aged 15-35 years. Generally, diagnosing and follow-up include computer tomography (CT) examinations to detect possible retroperitoneal spread (abdomen and pelvis), resulting in at least eight CT examinations. This patient group is thereby exposed to a non-neglectable radiation dose, increasing the risk of future radiation-induced secondary cancer. This is especially problematic in potentially surgically cured patients with stage 1 testicular cancer. Thus, it can be beneficial to substitute CT with magnetic resonance imaging (MRI), provided there is valid evidence that the diagnostic value of MRI is at least comparable to current multislice CT (MSCT). The purpose of this study was to analyze whether there is evidence to recommend a substitution of MSCT with MRI in the diagnosis of retroperitoneal spread of testicular cancer. A literature search on the diagnostic accuracy, specificity, and sensitivity of MSCT and MRI in the diagnosis of retroperitoneal spread of testicular cancer was performed in the following databases: PubMed, EmBase, and ISI Web of Science. The search was limited to include the period from 2000 to September 2008, and to human and English-language publications. Forty-four publications were obtained for formal review (27 from PubMed, 15 from EmBase, two from ISI Web of Science). None of the publications reviewed encompassed diagnostic specificity and sensitivity of MSCT, and they lacked systematic comparison of MSCT and MRI. Only one study included sensitivity and specificity of MRI compared to single-slice CT. Both methods had a sensitivity and a specificity of approximately 70%. The literature review did not reveal valid data regarding diagnostic accuracy of MRI compared with MSCT for diagnosing retroperitoneal spread of testicular cancer. A prospective blinded comparative study is needed to provide valid evidence

  18. Diagnostic Value of Multislice Computed Tomography and Magnetic Resonance Imaging in the Diagnosis of Retroperitoneal Spread of Testicular Cancer: A Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, J. (Dept. of Medical Physics, Aarhus Univ. Hospital, Aarhus Sygehus, Aarhus (Denmark)); Jurik, A.G. (Dept. of Radiology, Aarhus Univ. Hospital, Aarhus Sygehus, Aarhus (Denmark))

    2009-11-15

    Testicular cancer is the most frequent malignant disorder in men aged 15-35 years. Generally, diagnosing and follow-up include computer tomography (CT) examinations to detect possible retroperitoneal spread (abdomen and pelvis), resulting in at least eight CT examinations. This patient group is thereby exposed to a non-neglectable radiation dose, increasing the risk of future radiation-induced secondary cancer. This is especially problematic in potentially surgically cured patients with stage 1 testicular cancer. Thus, it can be beneficial to substitute CT with magnetic resonance imaging (MRI), provided there is valid evidence that the diagnostic value of MRI is at least comparable to current multislice CT (MSCT). The purpose of this study was to analyze whether there is evidence to recommend a substitution of MSCT with MRI in the diagnosis of retroperitoneal spread of testicular cancer. A literature search on the diagnostic accuracy, specificity, and sensitivity of MSCT and MRI in the diagnosis of retroperitoneal spread of testicular cancer was performed in the following databases: PubMed, EmBase, and ISI Web of Science. The search was limited to include the period from 2000 to September 2008, and to human and English-language publications. Forty-four publications were obtained for formal review (27 from PubMed, 15 from EmBase, two from ISI Web of Science). None of the publications reviewed encompassed diagnostic specificity and sensitivity of MSCT, and they lacked systematic comparison of MSCT and MRI. Only one study included sensitivity and specificity of MRI compared to single-slice CT. Both methods had a sensitivity and a specificity of approximately 70%. The literature review did not reveal valid data regarding diagnostic accuracy of MRI compared with MSCT for diagnosing retroperitoneal spread of testicular cancer. A prospective blinded comparative study is needed to provide valid evidence

  19. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Mukai, Eiichiro; Makino, Naoki; Fujishiro, Kenichiro.

    1989-01-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author)

  20. Magnetic resonance imaging of Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Eiichiro [National Hospital of Nagoya (Japan); Makino, Naoki; Fujishiro, Kenichiro

    1989-06-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author).

  1. Diagnostic accuracy of 3-T magnetic resonance imaging with 3D T1 VIBE versus computer tomography in pars stress fracture of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Ang, E.C.; Robertson, A.F.; Malara, F.A.; O' Shea, T.; Roebert, J.K.; Rotstein, A.H. [Victoria House Medical Imaging, Prahran, Victoria (Australia); Schneider, M.E. [Monash University, Monash Biomedicine Discovery Institute, Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Clayton, Victoria (Australia)

    2016-11-15

    To compare the diagnostic accuracy of 3-T magnetic resonance imaging (MRI) with thin-slice 3D T1 VIBE sequence to 128-slice computer tomography (CT) in pars stress fractures of the lumbar spine. 3-T MRI and CT of 24 patients involving 70 pars interarticularis were retrospectively reviewed by four blinded radiologists. The fracture morphology (complete, incomplete, or normal) was assessed on MRI and CT at different time points. Pars interarticularis bone marrow edema (present or absent) was also evaluated on MRI. In total, 14 complete fractures, 31 incomplete fractures and 25 normal pars were detected by CT. Bone marrow edema was seen in seven of the complete and 25 of the incomplete fractures. The overall sensitivity, specificity and accuracy of MRI in detecting fractures (complete and incomplete) were 97.7, 92.3, and 95.7 %, respectively. MRI was 100 % accurate in detecting complete fractures. For incomplete fractures, the sensitivity, specificity, and accuracy of MRI were 96.7, 92.0, and 94.6 %, respectively. 3-T MRI with thin-slice 3D T1 VIBE is 100 % accurate in diagnosing complete pars fractures and has excellent diagnostic ability in the detection and characterization of incomplete pars stress fractures compared to CT. MRI has the added advantages of detecting bone marrow edema and does not employ ionizing radiation. (orig.)

  2. Diagnostic accuracy of 3-T magnetic resonance imaging with 3D T1 VIBE versus computer tomography in pars stress fracture of the lumbar spine

    International Nuclear Information System (INIS)

    Ang, E.C.; Robertson, A.F.; Malara, F.A.; O'Shea, T.; Roebert, J.K.; Rotstein, A.H.; Schneider, M.E.

    2016-01-01

    To compare the diagnostic accuracy of 3-T magnetic resonance imaging (MRI) with thin-slice 3D T1 VIBE sequence to 128-slice computer tomography (CT) in pars stress fractures of the lumbar spine. 3-T MRI and CT of 24 patients involving 70 pars interarticularis were retrospectively reviewed by four blinded radiologists. The fracture morphology (complete, incomplete, or normal) was assessed on MRI and CT at different time points. Pars interarticularis bone marrow edema (present or absent) was also evaluated on MRI. In total, 14 complete fractures, 31 incomplete fractures and 25 normal pars were detected by CT. Bone marrow edema was seen in seven of the complete and 25 of the incomplete fractures. The overall sensitivity, specificity and accuracy of MRI in detecting fractures (complete and incomplete) were 97.7, 92.3, and 95.7 %, respectively. MRI was 100 % accurate in detecting complete fractures. For incomplete fractures, the sensitivity, specificity, and accuracy of MRI were 96.7, 92.0, and 94.6 %, respectively. 3-T MRI with thin-slice 3D T1 VIBE is 100 % accurate in diagnosing complete pars fractures and has excellent diagnostic ability in the detection and characterization of incomplete pars stress fractures compared to CT. MRI has the added advantages of detecting bone marrow edema and does not employ ionizing radiation. (orig.)

  3. Thyroid perfusion imaging as a diagnostic tool in Graves' disease. Arterial spin labeling magnetic resonance imaging vs. colour-coded Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Muessig, K. [University Hospital of Duesseldorf (Germany). Dept. of Metabolic Diseases; Leibniz Center for Diabetes Research, Duesseldorf (Germany). Inst. for Clinical Diabetology; University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Schraml, C.; Schwenzer, N.F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology; Rietig, R.; Balletshofer, B. [University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Martirosian, P.; Haering, H.U.; Schick, F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; Claussen, C.D. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology

    2012-12-15

    Purpose: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. Materials and Methods: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. Results: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p = 0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. Conclusion: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value. (orig.)

  4. Diagnostic value of the flow profile in the distal descending aorta by phase-contrast magnetic resonance for predicting severe coarctation of the aorta.

    Science.gov (United States)

    Muzzarelli, Stefano; Ordovas, Karen Gomes; Hope, Michael D; Meadows, Jeffery J; Higgins, Charles B; Meadows, Alison Knauth

    2011-06-01

    To compare aortic flow profiles at the level of the proximal descending (PDAo) and distal descending aorta (DDAo) in patients investigated for coarctation of the aorta (CoA), and compare their respective diagnostic value for predicting severe CoA. Diastolic flow decay in the PDAo predicts severe CoA, but flow measurements at this level are limited by flow turbulence, aliasing, and stent-related artifacts. We studied 49 patients evaluated for CoA with phase contrast magnetic resonance imaging (PC-MRI). Parameters of diastolic flow decay in the PDAo and DDAo were compared. Their respective diagnostic value was compared with the standard reference of transcatheter peak gradient ≥20 mmHg. Flow measurement in the PDAo required repeated acquisition with adjustment of encoding velocity or location of the imaging plane in 69% of patients; measurement in the DDAo was achieved in single acquisition in all cases. Parameters of diastolic flow decay in the PDAo and DDAo, including rate-corrected (RC) deceleration time and RC flow deceleration yielded a good correlation (r = 0.78; P RC deceleration time at DDAo (sensitivity 85%, specificity 85%). Characterization of aortic flow profiles at the DDAo offers a quick and reliable noninvasive means of assessing hemodynamically significant CoA. Copyright © 2011 Wiley-Liss, Inc.

  5. Diagnostic efficacy of standard knee magnetic resonance imaging and radiography in evaluating integrity of anterior cruciate ligament before unicompartmental knee arthroplasty.

    Science.gov (United States)

    Altınel, Levent; Er, Mehmet Serhan; Kaçar, Emre; Erten, Recep Abdullah

    2015-01-01

    The purpose of this study was to investigate the diagnostic efficacy of standard magnetic resonance imaging (MRI) and plain radiographs in determining the status of anterior cruciate ligament (ACL) for surgical decision-making processes in cases of medial unicompartmental knee arthroplasty (UKA). A total of 59 knees of 36 consecutive patients who underwent knee replacement surgery were analyzed retrospectively. MRI scans were assessed independently by 3 observers (radiologists), while the plain radiographs were evaluated by an independent radiologist. Results were compared with the intraoperative ACL status. Cross tabulation was used for descriptive statistics to analyze sensitivity, specificity, and accuracy of MRI and plain radiographs. When the same observer assessed and classified the MRI twice, the reproducibility of the classification system varied from moderate to excellent. However, the interobserver concordance was moderate. The sensitivity of MRI was 73% and the specificity was 81%, while the sensitivity and specificity of plain radiographs was 36% and 79%, respectively. The accuracy of MRI was 80%, while that of the radiographs was 71%. Detection of intact ACL may be possible on available plain radiographs without necessity for additional means such as MRI, which may cause increase costs and loss of time. In cases where there is uncertainty regarding ACL integrity in degenerative knees, although standard MRI provides additional information on ACL status, it is not of sufficient diagnostic value.

  6. Magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries: protocol for a systematic review of diagnostic accuracy.

    Science.gov (United States)

    Wade, Ryckie G; Takwoingi, Yemisi; Wormald, Justin C R; Ridgway, John P; Tanner, Steven; Rankine, James J; Bourke, Grainne

    2018-05-19

    Adult brachial plexus injuries (BPI) are becoming more common. The reconstruction and prognosis of pre-ganglionic injuries (root avulsions) are different to other types of BPI injury. Preoperative magnetic resonance imaging (MRI) is being used to identify root avulsions, but the evidence from studies of its diagnostic accuracy are conflicting. Therefore, a systematic review is needed to address uncertainty about the accuracy of MRI and to guide future research. We will conduct a systematic search of electronic databases alongside reference tracking. We will include studies of adults with traumatic BPI which report the accuracy of preoperative MRI (index test) against surgical exploration of the roots of the brachial plexus (reference standard) for detecting either of the two target conditions (any root avulsion or any pseudomeningocoele as a surrogate marker of root avulsion). We will exclude case reports, articles considering bilateral injuries and studies where the number of true positives, false positives, false negatives and true negatives cannot be derived. The methodological quality of the included studies will be assessed using a tailored version of the QUADAS-2 tool. Where possible, a bivariate model will be used for meta-analysis to obtain summary sensitivities and specificities for both target conditions. We will investigate heterogeneity in the performance of MRI according to field strength and the risk of bias if data permits. This review will summarise the current diagnostic accuracy of MRI for adult BPI, identify shortcomings and gaps in the literature and so help to guide future research. PROSPERO CRD42016049702 .

  7. Magnetic resonance in neuroborreliosis

    International Nuclear Information System (INIS)

    Ustymowicz, A.; Zajkowska, J.

    2003-01-01

    Magnetic resonance (MR) is commonly used in diagnosing infections of the central nervous system. The aim of the study is to evaluate central nervous system changes in neuroborreliosis patients. MR examinations were performed in 44 patients with clinical symptoms, epidemiology and laboratory tests results of neuroborreliosis. Abnormalities were detected in 22 patients. Most of them presented cortico-subcortical atrophy (86%). In 9 cases foci of increased signal in T2-weighted and FLAIR images were observed in white matter. They were single or multiple, located subcorticaly and paraventriculary. In 2 subjects areas of increased signal were found in the brain stem. Central nervous system abnormalities detected with MR are not specific for Lyme disease. They can suggest demyelinating lesions and/or gliosis observed in many nervous system disorders (SM, ADEM, lacunar infarcts). (author)

  8. Cine magnetic resonance

    International Nuclear Information System (INIS)

    Higgins, C.B.; Sechtem, U.P.; Pflugfelder, P.

    1987-01-01

    Cine magnetic resonance (MR) is a fast MR imaging process with referencing of the imaging data to the electrocardiogram (ECG) so that images corresponding to 21-msec segments of the cardiac cycle are acquired. A series of such images, each corresponding to a 21-msec segment of the cardiac cycle, can be laced together for viewing in the cine format at a framing rate of 20 to 40 frames per second. Since cine angiograms of the heart are usually done at 30 frames per second, this technique achieves a temporal resolution adequate for the evluation of central cardiovascular function. The major application of this technique is to depict central cardiovascular function and blood flow

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful ... for an MRI exam contains a metal called gadolinium . Gadolinium can be used in patients with iodine ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... work? Unlike conventional x-ray examinations and computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, ... Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses ... identify and accurately characterize diseases than other imaging methods. This detail makes MRI an invaluable tool in ...

  12. Magnetic resonance of low dimensional magnetic solids

    Energy Technology Data Exchange (ETDEWEB)

    Gatteschi, D.; Ferraro, F.; Sessoli, R. (Florence Univ. (Italy))

    1994-06-01

    The utility of EPR and NMR in the study of low-dimensional magnetic solids is shown. A short summary of the basis of magnetic resonance in these systems is reported, and the importance of spin-diffusion and magnetic anisotropy evidenced. Some results from experiments on metal-radical chains and clusters are presented. (authors). 37 refs., 7 figs.

  13. Magnetic resonance of low dimensional magnetic solids

    International Nuclear Information System (INIS)

    Gatteschi, D.; Ferraro, F.; Sessoli, R.

    1994-01-01

    The utility of EPR and NMR in the study of low-dimensional magnetic solids is shown. A short summary of the basis of magnetic resonance in these systems is reported, and the importance of spin-diffusion and magnetic anisotropy evidenced. Some results from experiments on metal-radical chains and clusters are presented. (authors). 37 refs., 7 figs

  14. Advances in magnetic resonance 12

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 12, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains six chapters and begins with a discussion of diffusion and self-diffusion measurements by nuclear magnetic resonance. This is followed by separate chapters on spin-lattice relaxation time in hydrogen isotope mixtures; the principles of optical detection of nuclear spin alignment and nuclear quadropole resonance; and the spin-1 behavior, including the relaxation of the quasi-invariants of the motion of a system of pairs of dipolar coupled spin-1/2 nu

  15. Magnetic resonance imaging methodology

    International Nuclear Information System (INIS)

    Moser, Ewald; Stadlbauer, Andreas; Windischberger, Christian; Quick, Harald H.; Ladd, Mark E.

    2009-01-01

    Magnetic resonance (MR) methods are non-invasive techniques to provide detailed, multi-parametric information on human anatomy, function and metabolism. Sensitivity, specificity, spatial and temporal resolution may, however, vary depending on hardware (e.g., field strength, gradient strength and speed) and software (optimised measurement protocols and parameters for the various techniques). Furthermore, multi-modality imaging may enhance specificity to better characterise complex disease patterns. Positron emission tomography (PET) is an interesting, largely complementary modality, which might be combined with MR. Despite obvious advantages, combining these rather different physical methods may also pose challenging problems. At this early stage, it seems that PET quality may be preserved in the magnetic field and, if an adequate detector material is used for the PET, MR sensitivity should not be significantly degraded. Again, this may vary for the different MR techniques, whereby functional and metabolic MR is more susceptible than standard anatomical imaging. Here we provide a short introduction to MR basics and MR techniques, also discussing advantages, artefacts and problems when MR hardware and PET detectors are combined. In addition to references for more detailed descriptions of MR fundamentals and applications, we provide an early outlook on this novel and exciting multi-modality approach to PET/MR. (orig.)

  16. Diagnostic utility of magnetic resonance imaging and radiography in juvenile spondyloarthritis: evaluation of the sacroiliac joints in controls and affected subjects.

    Science.gov (United States)

    Jaremko, Jacob L; Liu, Lei; Winn, Naomi J; Ellsworth, Janet E; Lambert, Robert G W

    2014-05-01

    To compare the utility of radiography and magnetic resonance imaging (MRI) for the diagnosis of juvenile-onset spondyloarthritis in pediatric patients presenting with low back and/or sacroiliac (SI) pain of potentially inflammatory etiology. Radiographs and MRI studies of the SI joints in 26 patients with juvenile spondyloarthritis (JSpA) and 35 controls were assessed independently by 2 radiologists, with discrepancies arbitrated by a third. Radiographs and MRI were blinded and read in separate batches in random order. Erosion was common and was the most useful diagnostic feature on radiography [positive likelihood ratio (LR) = 3.5] and was especially diagnostic of SpA on MRI (LR = 6.7). Subchondral sclerosis was common but was the least specific feature for both modalities. Joint space narrowing had some utility on radiography (LR = 2.0) and MRI (LR = 2.7) but was uncommon and had poor reader reliability. Bone marrow edema (LR = 3.1) and subarticular fat infiltration (LR = 4.5), detectable only on MRI, were both useful features. Global diagnostic impression of MRI (LR = 9.4) had very high utility for the diagnosis of JSpA, exceeding radiography (LR = 4.4) because of superior specificity. In addition, global diagnosis of SpA is much more reliably made on MRI (κ = 0.80) compared to radiography (κ = 0.30). Specificity and reliability of MRI of the SI joints are superior to radiography for the diagnosis of juvenile-onset SpA and, where available, MRI should replace radiography as the first line of investigation.

  17. Magnetic resonance imaging of the central nervous system

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Norman, D.

    1987-01-01

    This book presents the papers on technological advancement and diagnostic uses g magnetic resonance imaging. A comparative evaluation with computerized tomography is presented. Topics covered are imaging principles g magnetic resonance;instrumentation of magnetic resonance (MR);pathophysiology;quality and limitations g images;NMR imaging of brain and spinal cord;MR spectroscopy and its applications;neuroanatomy;Congenital malformations of brain and MR imaging;planning g MR imaging of spine and head and neck imaging

  18. Diagnostic value of whole-body diffusion-weighted magnetic resonance imaging for detection of primary and metastatic malignancies: A meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, Bin, E-mail: lllb146@163.com [Department of Radiology, Shanghai Changzheng Hospital, Second Military Medical University, Shanghai 200003 (China); Li, Qiong [Department of Radiology, Shanghai Changzheng Hospital, Second Military Medical University, Shanghai 200003 (China); Nie, Wei [Department of Respiratory Disease, Shanghai Changzheng Hospital, Second Military Medical University, Shanghai 200003 (China); Liu, Shiyuan, E-mail: lsy20112077@163.com [Department of Radiology, Shanghai Changzheng Hospital, Second Military Medical University, Shanghai 200003 (China)

    2014-02-15

    Purpose: To perform a meta-analysis to evaluate the diagnostic performance of whole-body diffusion-weighted magnetic resonance imaging (WB-DWI) technique in detection of primary and metastatic malignancies compared with that of whole-body positron emission tomography/computed tomography (WB-PET/CT). Materials and methods: Search Pubmed, MEDLINE, EMBASE and Cochrane Library database from January 1984 to July 2013 for studies comparing WB-DWI with WB-PET/CT for detection of primary and metastatic malignancies. Methodological quality was assessed by the quality assessment of diagnostic studies (QUADAS) instrument. Sensitivities, specificities, predictive values, diagnostic odds ratio (DOR) and areas under the summary receiver operator characteristic curve (AUC) were calculated. Potential threshold effect, heterogeneity and publication bias were investigated. Result: Thirteen eligible studies were included, with a total of 1067 patients. There was no significant threshold effect. WB-DWI had a similar AUC (0.966 (95% CI, 0.940–0.992) versus 0.984 (95% CI, 0.965–0.999)) with WB-PET/CT. No significant difference was detected between AUC of WB-DWI and WB-PET/CT. WB-DWI had a pooled sensitivity of 0.897 (95% CI, 0.876–0.916) and a pooled specificity of 0.954 (95% CI, 0.944–0.962). WB-PET/CT had a pooled sensitivity of 0.895 (95% CI, 0.865–0.920) and a pooled specificity of 0.975 (95% CI, 0.966–0.981). Heterogeneity was found to stem primarily from data type (per lesion versus per patient), MR sequence (DWIBS only and DWIBS with other sequence), and primary lesion type (single type and multiple type). The Deeks's funnel plots suggested the absence of publication bias. Conclusion: WB-DWI has similar, good diagnostic performance for the detection of primary and metastatic malignancies compared with WB-PET/CT. DWIBS with other MR sequences could further improve the diagnostic performance. More high-quality studies regarding comparison of WB-DWI and WB

  19. Low field magnetic resonance imaging

    Science.gov (United States)

    Pines, Alexander; Sakellariou, Dimitrios; Meriles, Carlos A.; Trabesinger, Andreas H.

    2010-07-13

    A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

  20. Presurgical functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Stippich, C.

    2010-01-01

    Functional magnetic resonance imaging (fMRI) is an important and novel neuroimaging modality for patients with brain tumors. By non-invasive measurement, localization and lateralization of brain activiation, most importantly of motor and speech function, fMRI facilitates the selection of the most appropriate and sparing treatment and function-preserving surgery. Prerequisites for the diagnostic use of fMRI are the application of dedicated clinical imaging protocols and standardization of the respective imaging procedures. The combination with diffusion tensor imaging (DTI) also enables tracking and visualization of important fiber bundles such as the pyramidal tract and the arcuate fascicle. These multimodal MR data can be implemented in computer systems for functional neuronavigation or radiation treatment. The practicability, accuracy and reliability of presurgical fMRI have been validated by large numbers of published data. However, fMRI cannot be considered as a fully established modality of diagnostic neuroimaging due to the lack of guidelines of the responsible medical associations as well as the lack of medical certification of important hardware and software components. This article reviews the current research in the field and provides practical information relevant for presurgical fMRI. (orig.) [de

  1. Magnetic resonance in multiple sclerosis

    International Nuclear Information System (INIS)

    Scotti, G.; Caputo, D.; Cazzullo, C.L.

    1986-01-01

    Magnetic Resonance Imaging was performed in more than 200 patients with clinical suspicion or knowledge of Multiple Sclerosis. One hundred and forty-seven (60 males and 87 females) had MR evidence of multiple sclerosis lesions. The MR signal of demyelinating plaques characteristically has prolonged T1 and T2 relaxation times and the T2-weighted spin-echo sequences are generally superior to the T1-weighted images because the lesions are better visualized as areas of increased signal intensity. MR is also able to detect plaques in the brainstem, cerebellum and within the cervical spinal cord. MR appears to be an important, non-invasive method for the diagnosis of Multiple Sclerosis and has proven to be diagnostically superior to CT, evoked potentials (EP) and CSF examination. In a selected group of 30 patients, with the whole battery of the relevant MS studies, MR was positive in 100%, CT in 33,3%, EP in 56% and CSF examination in 60%. In patients clinically presenting only with signs of spinal cord involvement or optic neuritis or when the clinical presentation is uncertain MR has proven to be a very useful diagnostic tool for diagnosis of MS by demonstrating unsuspected lesions in the cerebral hemispheres. (orig.)

  2. Parallel magnetic resonance imaging

    International Nuclear Information System (INIS)

    Larkman, David J; Nunes, Rita G

    2007-01-01

    Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial encoding in MRI is followed by an introduction to the problem parallel imaging is designed to solve. There are a large number of parallel reconstruction algorithms; this article reviews a cross-section, SENSE, SMASH, g-SMASH and GRAPPA, selected to demonstrate the different approaches. Theoretical (the g-factor) and practical (coil design) limits to acquisition speed are reviewed. The practical implementation of parallel imaging is also discussed, in particular coil calibration. How to recognize potential failure modes and their associated artefacts are shown. Well-established applications including angiography, cardiac imaging and applications using echo planar imaging are reviewed and we discuss what makes a good application for parallel imaging. Finally, active research areas where parallel imaging is being used to improve data quality by repairing artefacted images are also reviewed. (invited topical review)

  3. Noncontrast Magnetic Resonance Lymphography.

    Science.gov (United States)

    Arrivé, Lionel; Derhy, Sarah; El Mouhadi, Sanaâ; Monnier-Cholley, Laurence; Menu, Yves; Becker, Corinne

    2016-01-01

    Different imaging techniques have been used for the investigation of the lymphatic channels and lymph glands. Noncontrast magnetic resonance (MR) lymphography has significant advantages in comparison with other imaging modalities. Noncontrast MR lymphography uses very heavily T2-weighted fast spin echo sequences which obtain a nearly complete signal loss in tissue background and specific display of lymphatic vessels with a long T2 relaxation time. The raw data can be processed with different algorithms such as maximum intensity projection algorithm to obtain an anatomic representation. Standard T2-weighted MR images easily demonstrate the location of edema. It appears as subcutaneous infiltration of soft tissue with a classical honeycomb pattern. True collection around the muscular area may be demonstrated in case of severe lymphedema. Lymph nodes may be normal in size, number, and signal intensity; in other cases, lymph nodes may be smaller in size or number of lymph nodes may be restricted. MR lymphography allows a classification of lymphedema in aplasia (no collecting vessels demonstrated); hypoplasia (a small number of lymphatic vessels), and numerical hyperplasia or hyperplasia (with an increased number of lymphatic vessels of greater and abnormal diameter). Noncontrast MR lymphography is a unique noninvasive imaging modality for the diagnosis of lymphedema. It can be used for positive diagnosis, differential diagnosis, and specific evaluation of lymphedema severity. It may also be used for follow-up evaluation after treatment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Magnetic resonance imaging. 1

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Roos, A.A. de; Doornbos, J.; Dijkman, P.R.M. van; Matheijssen, N.A.A.; Laarse, A. van der; Krauss, X.H.; Blokland, J.A.k.; Manger Cats, V.; Voorthuisen, A.E. van; Bruschke, A.V.G.

    1991-01-01

    The cardiovascular applications of MRI in coronary artery disease have considerably increased in recent years. Although many applications overlap those of other more cost-effective techniques, such as echocardiography, radionuclide angiography, and CT, MRI offers unique features not shared by the conventional techniques. Technical advantages are the excellent spatial resolution, the characterization of myocardial tissue, and the potential for three-dimensional imaging. This allows the accurate assessment of left ventricular mass and volume, the differentiation of infarcted tissue from normal myocardial tissue, and the determination of systolic wall thickening and regional wall motion abnormalities. Also inducible myocardial ischemia using pharmacological stress (dipyramidole or dobutamine) may be assessed by magnetic resonance imaging. Future technical developments include real-time imaging and noninvasive visualization of the coronary arteries. These advantages will have a major impact on the application of MRI in coronary artery disease, potentially unsurpassed by other techniques and certainly justifying the expenses. Consequently, the clinical use of MRI for the detection of coronary artery disease largely depends on the progress of technical developments. (author). 134 refs.; 10 figs.; 2 tabs

  5. Advances in magnetic resonance 9

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 9 describes the magnetic resonance in split constants and dipolar relaxation. This book discusses the temperature-dependent splitting constants in the ESR spectra of organic free radicals; temperature-dependent splittings in ion pairs; and magnetic resonance induced by electrons. The electron impact excitation of atoms and molecules; intramolecular dipolar relaxation in multi-spin systems; and dipolar cross-correlation problem are also elaborated. This text likewise covers the NMR studies of molecules oriented in thermotropic liquid crystals and diffusion

  6. Advances in magnetic resonance 1

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 1, discusses developments in various areas of magnetic resonance. The subject matter ranges from original theoretical contributions through syntheses of points of view toward series of phenomena to critical and painstaking tabulations of experimental data. The book contains six chapters and begins with a discussion of the theory of relaxation processes. This is followed by separate chapters on the development of magnetic resonance techniques for studying rate processes in chemistry and the application of these techniques to various problems; the geometri

  7. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    Science.gov (United States)

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally

  8. Diagnostic value of the evaluation of the glycogen content in muscle diseases by carbon 13 nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Jehenson, P.; Syrota, A.; Labrune, P.; Odievre, M.; Fardeau, M.

    1995-01-01

    We have developed a method for the evaluation of the muscle glycogen content by natural abundance C13 NMR and we here evaluate its diagnostic value on a large number of muscle diseases (20 glycogenoses and 42 other myopathies) and 8 normal subjects. The results show high values of the glycogen/creatine ratio in muscle glycogenoses, with no overlap with other diseased or normal subjects. This evaluation of the muscle glycogen content, which is performed at rest and thus easily applicable, in particular for children, is thus very sensitive and specific for the diagnosis of muscle glycogenosis. (authors). 9 refs

  9. Diagnostic Magnetic Resonance Imaging of Atherosclerosis in Apolipoprotein E Knockout Mouse Model Using Macrophage-Targeted Gadolinium-Containing Synthetic Lipopeptide Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Zu T Shen

    Full Text Available Cardiovascular disease is the leading cause of death in Western cultures. The vast majority of cardiovascular events, including stroke and myocardial infarction, result from the rupture of vulnerable atherosclerotic plaques, which are characterized by high and active macrophage content. Current imaging modalities including magnetic resonance imaging (MRI aim to characterize anatomic and structural features of plaques rather than their content. Previously, we reported that macrophage-targeted delivery of gadolinium (Gd-based contrast agent (GBCA-HDL using high density lipoproteins (HDL-like particles significantly enhances the detection of plaques in an apolipoprotein (apo E knockout (KO mouse model, with an atherosclerotic wall/muscle normalized enhancement ratio (NER of 120% achieved. These particles are comprised of lipids and synthetic peptide fragments of the major protein of HDL, apo A-I, that contain a naturally occurring modification which targets the particles to macrophages. Targeted delivery minimizes the Gd dose and thus reduces the adverse effects of Gd. The aims of the current study were to test whether varying the GBCA-HDL particle shape and composition can further enhance atherosclerotic plaque MRI and control organ clearance of these agents. We show that the optimized GBCA-HDL particles are efficiently delivered intracellularly to and uptaken by both J774 macrophages in vitro and more importantly, by intraplaque macrophages in vivo, as evidenced by NER up to 160% and higher. This suggests high diagnostic power of our GBCA-HDL particles in the detection of vulnerable atherosclerotic plaques. Further, in contrast to discoidal, spherical GBCA-HDL exhibit hepatic clearance, which could further diminish adverse renal effects of Gd. Finally, activated macrophages are reliable indicators of any inflamed tissues and are implicated in other areas of unmet clinical need such as rheumatoid arthritis, sepsis and cancer, suggesting the

  10. The diagnostic accuracy of magnetic resonance venography in the detection of deep venous thrombosis: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Abdalla, G.; Fawzi Matuk, R.; Venugopal, V.; Verde, F.; Magnuson, T.H.; Schweitzer, M.A.; Steele, K.E.

    2015-01-01

    Aim: To search the literature for further evidence for the use of magnetic resonance venography (MRV) in the detection of suspected DVT and to re-evaluate the accuracy of MRV in the detection of suspected deep vein thrombosis (DVT). Materials and methods: PubMed, EMBASE, Scopus, Cochrane, and Web of Science were searched. Study quality and the risk of bias were evaluated using the QUADAS 2. A random effects meta-analysis including subgroup and sensitivity analyses were performed. Results: The search resulted in 23 observational studies all from academic centres. Sixteen articles were included in the meta-analysis. The summary estimates for MRV as a diagnostic non-invasive tool revealed a sensitivity of 93% (95% confidence interval [CI]: 89% to 95%) and specificity of 96% (95% CI: 94% to 97%). The heterogeneity of the studies was high. Inconsistency (I2) for sensitivity and specificity was 80.7% and 77.9%, respectively. Conclusion: Further studies investigating the use of MRV in the detection of suspected DVT did not offer further evidence to support the replacement of ultrasound with MRV as the first-line investigation. However, MRV may offer an alternative tool in the detection/diagnosis of DVT for whom ultrasound is inadequate or not feasible (such as in the obese patient). -- Highlights: •We aimed to search the literature for evidence for the use of MRV in the detection of suspected DVT. •We questioned the use of MRV in special populations like the obese where contrast venography may not be feasible or safe. •MRV may not replace ultrasound as the first-line modality for DVT detection. •Consider MRV use in special populations like the obese where other diagnostic tools are not feasible. •Studies to compare MRV vs. ultrasound as a screening tool for DVT in the obese should be considered

  11. Diagnostic Accuracy and Inter-Observer Agreement of Shoulder Magnetic Resonance Arthrography in the Detection of Labral Lesion and Assessment of Lesion Location

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Song, Sook Yun; Choi, Jin Ha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic accuracy and inter-observer agreement of magnetic resonance (MR) arthrography in the detection of labral lesions by location and to describe useful MR imaging findings of labral tears. Sixty-eight patients who underwent both pre-operative MR arthrography and arthroscopy were included. The location of the labrum was classified into anterior (2-6 o'clock), superior (12-2 o'clock), and posterior (6-12 o'clock). Sensitivity, specificity, accuracy, and inter-observer agreement of MR arthrography for the diagnosis of labral lesions by location were calculated. Frequency of MR imaging findings such as detachment, high signal intensity cleft, contour change, absence, and signal change of the labrum by location were analyzed. 35 anterior, 44 superior and 15 posterior labral lesions were detected by arthroscopy. The corresponding sensitivities were 91.4%, 79.5%, and 40.0%, specificities were 90.9%, 20.8%, and 86.8%, accuracies were 91.2%, 58.8%, and 76.5%, and kappa values were 0.823, 0.252, and 0.394, for anterior, superior, posterior lesions, respectively. The most common MR imaging findings were detachment in 60.0% of anterior labrums, high signal intensity cleft in 52.3% of superior labrums, and normal in 60.0% of posterior labrums. Diagnostic accuracy and inter-observer agreement of MR arthrography in the diagnosis of labral lesions are high in anterior labrums and low in superior or posterior labrums. The useful MR imaging findings of labral tears were different according to labral location.

  12. The Effects of Voxel Localization and Time of Echo on the Diagnostic Accuracy of Cystic Brain Tumors in 3 Tesla Magnetic Resonance Spectroscopy

    International Nuclear Information System (INIS)

    Rezvanizadeh, Alireza; Firouznia, Kavous; Salehi-Sadaghiani, Mohammad; Mohseni, Meisam; Gharaei, Dona; Ghanaati, Hossein; Saligheh Rad, Hamidreza; Masoudnia, Majid

    2012-01-01

    Although magnetic resonance spectroscopy (MRS) has been shown as an effective diagnostic tool in distinguishing inflammation from neoplasm in cystic brain lesions, the optimum approach in selecting the portions of lesions in MRS and the possible effects of different times of echoes (TEs) remains unknown. To determine the most effective TE in diagnosing neoplastic lesions based on detecting choline (Cho), N acetyl aspartate (NAA) and creatinine (Cr). Moreover, the role of voxel localization on the diagnosis of the neoplastic nature of the lesions is assessed through comparing the abovementioned metabolite ratios in the rim and center of each lesion with the same TE. In 16 patients with brain cystic tumors, MRS was performed at TEs of 30, 135 and 270 ms for detection of Cho, NAA and Cr metabolites using a 3 tesla MRI unit. The percentage of analyzed ratios greater than a cut-off point of 1.3 for Cho/Cr and 1.6 for Cho/NAA were calculated. Cho/Cr and Cho/NAA ratio means at all TEs were more at the central area in comparison with the periphery, although none of the differences were statistically significant. There was no statistically significant difference among the compared TEs. The percentages of ratios above the cut-off point at all TEs were more in the rim compared to the center and in the union of both compared to the rim or center. All the patients had at least one voxel with a Cho/Cr ratio of more than 1.3 when the voxel was chosen according to the hotspots shown in the chemical shift imaging map, regardless of their location at all examined TEs. Selection of voxels with the guide of chemical shift imaging map yields to 100% diagnostic sensitivity. If not accessible, the use of the union of peripheral and central voxels enhances the sensitivity when compared to usage of peripheral or central voxels solely

  13. Diagnostic performance of magnetic resonance imaging in the assessment of periosteal reactions in bone sarcomas using conventional radiography as the reference

    Science.gov (United States)

    de Sá Neto, José Luiz; Simão, Marcelo Novelino; Crema, Michel Daoud; Engel, Edgard Eduard; Nogueira-Barbosa, Marcello Henrique

    2017-01-01

    Objective: To evaluate the performance of magnetic resonance imaging (MRI) in detecting periosteal reactions and to compare MRI and conventional radiography (CR) in terms of the classification of periosteal reactions. Materials and Methods: Retrospective study of 42 consecutive patients (mean age, 22 years; 20 men) with a confirmed diagnosis of osteosarcoma or Ewing's sarcoma, MRI and CR images having been acquired pretreatment. Three blinded radiologists detected periosteal reactions and evaluated each periosteal reaction subtype in CR and MRI images: Codman's triangle; laminated; and spiculated. The CR was used as a benchmark to calculate the diagnostic performance. We used the kappa coefficient to assess interobserver reproducibility. A two-tailed Fisher's exact test was used in order to assess contingency between CR and MRI classifications. Results: In the detection of periosteal reactions, MRI showed high specificity, a high negative predictive value, and low-to-moderate sensitivity. For CR and for MRI, the interobserver agreement for periosteal reaction was almost perfect, whereas, for the classification of different subtypes of periosteal reaction, it was higher for the Codman's triangle subtype and lower for the spiculated subtype. There was no significant difference between MRI and CR in terms of the classifications (p < 0.05). Conclusion: We found no difference between MRI and CR in terms of their ability to classify periosteal reactions. MRI showed high specificity and almost perfect interobserver agreement for the detection of periosteal reactions. The interobserver agreement was variable for the different subtypes of periosteal reaction. PMID:28670029

  14. Diagnostic performance of magnetic resonance imaging in the assessment of periosteal reactions in bone sarcomas using conventional radiography as the reference

    Directory of Open Access Journals (Sweden)

    José Luiz de Sá Neto

    Full Text Available Abstract Objective: To evaluate the performance of magnetic resonance imaging (MRI in detecting periosteal reactions and to compare MRI and conventional radiography (CR in terms of the classification of periosteal reactions. Materials and Methods: Retrospective study of 42 consecutive patients (mean age, 22 years; 20 men with a confirmed diagnosis of osteosarcoma or Ewing's sarcoma, MRI and CR images having been acquired pretreatment. Three blinded radiologists detected periosteal reactions and evaluated each periosteal reaction subtype in CR and MRI images: Codman's triangle; laminated; and spiculated. The CR was used as a benchmark to calculate the diagnostic performance. We used the kappa coefficient to assess interobserver reproducibility. A two-tailed Fisher's exact test was used in order to assess contingency between CR and MRI classifications. Results: In the detection of periosteal reactions, MRI showed high specificity, a high negative predictive value, and low-to-moderate sensitivity. For CR and for MRI, the interobserver agreement for periosteal reaction was almost perfect, whereas, for the classification of different subtypes of periosteal reaction, it was higher for the Codman's triangle subtype and lower for the spiculated subtype. There was no significant difference between MRI and CR in terms of the classifications (p < 0.05. Conclusion: We found no difference between MRI and CR in terms of their ability to classify periosteal reactions. MRI showed high specificity and almost perfect interobserver agreement for the detection of periosteal reactions. The interobserver agreement was variable for the different subtypes of periosteal reaction.

  15. Diagnostic accuracy of magnetic resonance angiography for detection of coronary artery disease: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Di Leo, Giovanni [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Fisci, Erica [Universita degli Studi di Genova, Scuola di Specializzazione in Radiodiagnostica, Genova (Italy); Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Universita degli Studi di Milano, PhD Course in Integrative Biomedical Research, Milan (Italy); Ali, Marco [Universita degli Studi di Milano, PhD Course in Integrative Biomedical Research, Milan (Italy); Ambrogi, Federico [Universita degli Studi di Milano, Department of Clinical Sciences and Community Health, Milan (Italy); Sconfienza, Luca Maria; Sardanelli, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy)

    2016-10-15

    To review the diagnostic performance of MR coronary angiography (MRCA) for coronary artery disease (CAD). Two independent reviewers searched on MEDLINE/EMBASE with the following inclusion criteria: 01/01/2000-03/23/2015 publication date; per-patient sensitivity/specificity for >50 % stenosis confirmed by conventional coronary angiography with raw data provided or retrievable; sample size >10. Quality was appraised using QUADAS2. Nine hundred eighteen studies were retrieved, 24 of them, including 1,638 patients, were selected. Using a bivariate model, the pooled sensitivity was 89 % (95 % confidence interval 86-92 %), the pooled specificity 72 % (63-79 %). Meta-regression did not show a significant impact on sensitivity/specificity for both year of publication and disease prevalence (p ≥ 0.114). Sensitivity of contrast-enhanced examinations (95 %, 90-97 %) was higher (p = 0.005) than that of unenhanced examinations (87 %, 83-90 %). Specificity of whole-heart acquisition mode (78 %, 72-84 %) was higher (p = 0.006) than that of targeted mode (57 %, 45-69 %). Specificity at 3 T (83 %, 69-92 %) was higher (p = 0.067) than that at 1.5 T (68 %, 60-76 %). Risk of bias and concerns regarding applicability were low. Sensitivity and specificity of MRCA for CAD were 89 % and 72 %, respectively. A specificity higher than 80 % may be obtained at 3 T. Whole-heart contrast-enhanced protocols should be preferred for a higher diagnostic performance. (orig.)

  16. Diagnostic accuracy of magnetic resonance angiography for detection of coronary artery disease: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Di Leo, Giovanni; Fisci, Erica; Secchi, Francesco; Ali, Marco; Ambrogi, Federico; Sconfienza, Luca Maria; Sardanelli, Francesco

    2016-01-01

    To review the diagnostic performance of MR coronary angiography (MRCA) for coronary artery disease (CAD). Two independent reviewers searched on MEDLINE/EMBASE with the following inclusion criteria: 01/01/2000-03/23/2015 publication date; per-patient sensitivity/specificity for >50 % stenosis confirmed by conventional coronary angiography with raw data provided or retrievable; sample size >10. Quality was appraised using QUADAS2. Nine hundred eighteen studies were retrieved, 24 of them, including 1,638 patients, were selected. Using a bivariate model, the pooled sensitivity was 89 % (95 % confidence interval 86-92 %), the pooled specificity 72 % (63-79 %). Meta-regression did not show a significant impact on sensitivity/specificity for both year of publication and disease prevalence (p ≥ 0.114). Sensitivity of contrast-enhanced examinations (95 %, 90-97 %) was higher (p = 0.005) than that of unenhanced examinations (87 %, 83-90 %). Specificity of whole-heart acquisition mode (78 %, 72-84 %) was higher (p = 0.006) than that of targeted mode (57 %, 45-69 %). Specificity at 3 T (83 %, 69-92 %) was higher (p = 0.067) than that at 1.5 T (68 %, 60-76 %). Risk of bias and concerns regarding applicability were low. Sensitivity and specificity of MRCA for CAD were 89 % and 72 %, respectively. A specificity higher than 80 % may be obtained at 3 T. Whole-heart contrast-enhanced protocols should be preferred for a higher diagnostic performance. (orig.)

  17. A comparison of early diagnostic utility of Alzheimer disease biomarkers in brain magnetic resonance and cerebrospinal fluid.

    Science.gov (United States)

    Monge Argilés, J A; Blanco Cantó, M A; Leiva Salinas, C; Flors, L; Muñoz Ruiz, C; Sánchez Payá, J; Gasparini Berenguer, R; Leiva Santana, C

    2014-09-01

    The goals of this study were to compare the early diagnostic utility of Alzheimer disease biomarkers in the CSF with those in brain MRI in conditions found in our clinical practice, and to ascertain the diagnostic accuracy of both techniques used together. Between 2008 and 2009, we included 30 patients with mild cognitive impairment (MCI) who were examined using 1.5 Tesla brain MRI and AD biomarker analysis in CSF. MRI studies were evaluated by 2 radiologists according to the Korf́s visual scale. CSF biomarkers were analysed using INNOTEST reagents for Aβ1-42, total-tau and phospho-tau181p. We evaluated clinical changes 2 years after inclusion. By 2 years after inclusion, 15 of the original 30 patients (50%) had developed AD (NINCDS-ADRA criteria). The predictive utility of AD biomarkers in CSF (RR 2.7; 95% CI, 1.1-6.7; Pde Neurología. Published by Elsevier Espana. All rights reserved.

  18. Magnetic resonance imaging of hypophysis

    International Nuclear Information System (INIS)

    Malla Huesh, I. V.

    2016-01-01

    nuclei and sulci. FLAIR - sequences with its advantage in suppressing the signal from the cerebrospinal fluid is useful in case of meningeal involvement in hypophysitis. DWI is essential in case of ischemia, apoplexy and associated necrotic changes. Contrast medium application is not compulsory, but it increases the sensitivity of the method, especially in young patients. The contrast used is Gadolinium, applied according to the body weight. After contrast application the gland enhances homogeneously. MR-methods made are responsible for throwing light upon the normal images of the pituitary gland from the neonatal patients to adults, explaining the malformative and rare conditions, leading to disturbances in the hypothalamic-pituitary axis. The most common reason for pathologic conditions in the hypothalamic-pituitary axis remain the adenomas. MR-imaging is the method of choice to rule out a suspected formation in the sellar area. Small adenomas with size around 3mm are now detectable with the use of equipment with high strength of magnetic field. Authors agree on the fact the secreting and nonsecreting adenomas need a thorough MR-follow up in time, especially the nonsecreting ones that are usually detected accidentally. In the era before the multislice diagnostic imaging the pathologies in the hypothalamic-pituitary axis were difficult to assess. The introduction of the new methods of investigation made the diagnosis of such conditions achievable. Magnetic resonance imaging is convenient, informative and clinically applicable for detecting hypothalamic-pituitary axis. However there is no agreement how the MR-protocol should be carried out. MR with high magnetic field is an essential tool in obtaining images with better quality, higher diagnostic value and the opportunity for performing sequences in thin slices and reconstructions in different planes. Key words: Magnetic Resonance Imaging. Hypophysis. 3TESLA

  19. The possibilities of magnetic resonance imaging in the diagnostics of complications after metal-on-metal hip arthroplasty

    Directory of Open Access Journals (Sweden)

    A. A. Vergay

    2013-01-01

    Full Text Available Objective: to find adverse periprosthetic local tissue reactions after metal-on-metal hip arthroplasty with ASR XL heads. Material and methods: 119 patients with 134 ASR XL head - Corail prostheses were treated in 2007-2009. The results were studied in 94 cases (105 prostheses - 84%. Average follow-up time consisted 62 ± 3 months. MRI was performed in 12 patients (13 hips who had clinical nonsatisfaction. Obtained data were compared with 21 MRI (24 hips of controlled group with good and perfect clinical results. Results. We found variations of normal periprosthetic tissue condition. Adverse reactions were identified in 10 cases. To improve the quality of pictures we developed special MRI adjustments and regimes of work. Conclusion: MRI diagnostics is indicated for the patients with metal-on-metal total hip arthroplasty in order to identify adverse local tissue reactions. The improvement of picture quality needs special adjustment of MRI equipment.

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Radiologist prepping patient for magnetic resonance ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or thyroid problems. Any of these conditions may influence the decision on whether contrast material will be ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the technologist or scheduler before the exam. ... patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... Image Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... necessary in trauma situations. Although there is no reason to believe that magnetic resonance imaging harms the ...

  11. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  12. Diagnostic equivalence of conventional and fast spin echo magnetic resonance imaging of the anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Munk, P.L.; Hilborn, M.D.; Vellet, A.D.; University of Calgary, Calgary, Alberta,; Romano, C.C.; University of Calgary, Calgary, Alberta,

    1997-01-01

    Many techniques and pulse sequences have been devised for the assessment of the anterior cruciate ligament. The present study compares fast spin echo (FSE) imaging to conventional spin echo imaging at a field strength of 1.5 T in an effort to determine if these sequences are diagnostically equivalent. Where available, arthroscopy was also done. A total of 52 patients were imaged using both FSE and conventional spin echo sequences. Eight volunteers were used as controls. Arthroscopy was performed on 10 patients. The anterior cruciate ligament was assessed in a blinded fashion by three radiologists. The Kappa statistic was then used to determine the percentage agreement between FSE and conventional spin echo imaging. Fast spin echo sequencing demonstrated a sensitivity of 100%, a specificity of 94.8% and an accuracy of 96.3% when compared to arthroscopy. Conventional spin echo imaging and arthroscopy had a sensitivity of 100%, specificity of 84.6% and an accuracy of 88.9%. The remaining 34 patients who did not undergo arthroscopy were followed clinically because clinical and imaging findings were not suggestive of ACL tears. These demonstrated 72% agreement between FSE and conventional spin echo imaging using the Kappa statistic, with regards to calling ACL normal or having only a low-grade partial tear. Fast spin echo imaging produces images of the anterior cruciate ligament that have similar diagnostic accuracy to conventional spin echo images (P<0.05) within a much shorter scan time. These results however, require further validation in a larger group, preferably with arthroscopic correlation. (author)

  13. Magnetic Resonance Imaging. Chapter 15

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M. O. [The Institute of Cancer Research and The Royal Marsden Hospital, London (United Kingdom)

    2014-09-15

    In Chapter 14, the principles of nuclear magnetic resonance were presented, along with an introduction to image forming processes. In this chapter, magnetic resonance imaging (MRI) will be reviewed, beginning with the hardware needed and its impact on image quality. The acquisition processes and image reconstruction will be discussed, as well as the artefacts that are possible, with discussion of the important area of safety and bioeffects completing the chapter.

  14. The nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Goyer, Ph.

    1997-01-01

    The spectroscopy of nuclear magnetic resonance constitutes a major analytical technique in biological and organic analysis. This technique appears now in the programme of preparatory classes and its teaching is developed in the second year of DEUG. The following article reviews on the nuclear magnetic resonance and on the possibilities it offers to bring to the fore the physico-chemical properties of molecules. (N.C.)

  15. Advances in magnetic resonance 2

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 2, features a mixture of experimental and theoretical contributions. The book contains four chapters and begins with an ambitious and general treatment of the problem of signal-to-noise ratio in magnetic resonance. This is followed by separate chapters on the interpretation of nuclear relaxation in fluids, with special reference to hydrogen; and various aspects of molecular theory of importance in NMR.

  16. Magnetic resonance imaging by using nano-magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Shokrollahi, H., E-mail: Shokrollahi@sutech.ac.ir [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Khorramdin, A. [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Isapour, Gh. [Department of Materials and Engineering, Hakim Sabzevari University (Iran, Islamic Republic of)

    2014-11-15

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants. - Highlights: • This paper studies the physics of MRI as a powerful diagnostic technique. • MRI uses the differentiation between healthy and pathological tissues. • The relaxation times can be shortened by the use of a magnetic contrast agent. • The magnetic nanoparticles act as contrast agents, helping to increase the resolution. • Different synthesis methods can influence the magnetic resonance behavior.

  17. A novel diagnostic parameter, foraminal stenotic ratio using three-dimensional magnetic resonance imaging, as a discriminator for surgery in symptomatic lumbar foraminal stenosis.

    Science.gov (United States)

    Yamada, Kentaro; Abe, Yuichiro; Satoh, Shigenobu; Yanagibashi, Yasushi; Hyakumachi, Takahiko; Masuda, Takeshi

    2017-08-01

    No previous studies have reported the radiological features of patients requiring surgery in symptomatic lumbar foraminal stenosis (LFS). This study aims to investigate the diagnostic accuracy of a novel technique, foraminal stenotic ratio (FSR), using three-dimensional magnetic resonance imaging for LFS at L5-S by comparing patients requiring surgery, patients with successful conservative treatment, and asymptomatic patients. This is a retrospective radiological comparative study. We assessed the magnetic resonance imaging (MRI) results of 84 patients (168 L5-S foramina) aged ≥40 years without L4-L5 lumbar spinal stenosis. The foramina were divided into three groups following standardized treatment: stenosis requiring surgery (20 foramina), stenosis with successful conservative treatment (26 foramina), and asymptomatic stenotic foramen (122 foramina). Foraminal stenotic ratio was defined as the ratio of the length of the stenosis to the length of the foramen on the reconstructed oblique coronal image, referring to perineural fat obliterations in whole oblique sagittal images. We also evaluated the foraminal nerve angle and the minimum nerve diameter on reconstructed images, and the Lee classification on conventional T1 images. The differences in each MRI parameter between the groups were investigated. To predict which patients require surgery, receiver operating characteristic (ROC) curves were plotted after calculating the area under the ROC curve. The FSR showed a stepwise increase when comparing asymptomatic, conservative, and surgical groups (mean, 8.6%, 38.5%, 54.9%, respectively). Only FSR was significantly different between the surgical and conservative groups (p=.002), whereas all parameters were significantly different comparing the symptomatic and asymptomatic groups. The ROC curve showed that the area under the curve for FSR was 0.742, and the optimal cutoff value for FSR for predicting a surgical requirement in symptomatic patients was 50

  18. Nuclear magnetic resonance and earth magnetic field

    International Nuclear Information System (INIS)

    Anon.

    1998-01-01

    Nuclear magnetic resonance concerns nuclei whose spin is different from 0. These nuclei exposed to a magnetic field is comparable to a peg top spinning around its axis while being moved by a precession movement called Larmor precession. This article presents an experiment whose aim is to reveal nuclear magnetism of nuclei by observing Larmor precession phenomena due to the earth magnetic field. The earth magnetic field being too weak, it is necessary to increase the magnetization of the sample during a polarization phase. First the sample is submitted to a magnetic field B perpendicular to the earth magnetic field B 0 , then B is cut off and the nuclei move back to their equilibrium position by executing a precession movement due to B 0 field. (A.C.)

  19. Diagnostic accuracy of post-mortem magnetic resonance imaging in fetuses, children and adults: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Thayyil, Sudhin, E-mail: s.thayyil@ucl.ac.u [Centre for Cardiovascular Imaging, UCL Institute of Child Health, London (United Kingdom); UCL Institute for Women' s Health, London (United Kingdom); Chandrasekaran, Manigandan [UCL Institute for Women' s Health, London (United Kingdom); Chitty, Lyn S. [UCL Institute for Women' s Health, London (United Kingdom); Clinical Molecular Genetics Unit, UCL Institute of Child Health, London (United Kingdom); Wade, Angie [Medical Statistics, UCL Institute of Child Health (United Kingdom); Skordis-Worrall, Jolene [Centre for International Health and Development, UCL Institute of Child Health (United Kingdom); Bennett-Britton, Ian [Centre for International Health and Development, UCL Institute of Child Health (United Kingdom); Health Economics and Financing Program, London School of Hygiene and Tropical Medicine, London (United Kingdom); Cohen, Marta [Department of Histopathology, Sheffield Children' s Hospital, Sheffield (United Kingdom); Withby, Elspeth [Department of Academic Radiology, Sheffield Children' s Hospital, Sheffield (United Kingdom); Sebire, Neil J. [Department of Histopathology, UCL Institute of Child Health and Great Ormond Street Hospital for Children, London (United Kingdom); Robertson, Nicola J. [UCL Institute for Women' s Health, London (United Kingdom); Taylor, Andrew M. [Centre for Cardiovascular Imaging, UCL Institute of Child Health, London (United Kingdom)

    2010-07-15

    To determine, in a systematic review, the diagnostic accuracy, acceptability and cost-effectiveness of less invasive autopsy by post-mortem MR imaging, in fetuses, children and adults. We searched Medline, Embase, the Cochrane library and reference lists to identify all studies comparing post-mortem MR imaging with conventional autopsy, published between January 1990 and March 2009. 539 abstracts were identified; 15 papers met the inclusion criteria; data from 9 studies were extracted (total: 146 fetuses, 11 children and 24 adults). In accurately identifying the final cause of death or most clinically significant abnormality, post-mortem MR imaging had a sensitivity and specificity of 69% (95% CI-56%, 80%) and 95% (95% CI-88%, 98%) in fetuses, and 28% (95% CI-13%, 47%) and 64% (95% CI-23%, 94%) in children and adults, respectively; however the published data is limited to small, heterogenous and poorly designed studies. Insufficient data is available on acceptability and economic evaluation of post-mortem MR imaging. Well designed, large, prospective studies are required to evaluate the accuracy of post-mortem MR imaging, before it can be offered as a clinical tool.

  20. Diagnostic accuracy of post-mortem magnetic resonance imaging in fetuses, children and adults: A systematic review

    International Nuclear Information System (INIS)

    Thayyil, Sudhin; Chandrasekaran, Manigandan; Chitty, Lyn S.; Wade, Angie; Skordis-Worrall, Jolene; Bennett-Britton, Ian; Cohen, Marta; Withby, Elspeth; Sebire, Neil J.; Robertson, Nicola J.; Taylor, Andrew M.

    2010-01-01

    To determine, in a systematic review, the diagnostic accuracy, acceptability and cost-effectiveness of less invasive autopsy by post-mortem MR imaging, in fetuses, children and adults. We searched Medline, Embase, the Cochrane library and reference lists to identify all studies comparing post-mortem MR imaging with conventional autopsy, published between January 1990 and March 2009. 539 abstracts were identified; 15 papers met the inclusion criteria; data from 9 studies were extracted (total: 146 fetuses, 11 children and 24 adults). In accurately identifying the final cause of death or most clinically significant abnormality, post-mortem MR imaging had a sensitivity and specificity of 69% (95% CI-56%, 80%) and 95% (95% CI-88%, 98%) in fetuses, and 28% (95% CI-13%, 47%) and 64% (95% CI-23%, 94%) in children and adults, respectively; however the published data is limited to small, heterogenous and poorly designed studies. Insufficient data is available on acceptability and economic evaluation of post-mortem MR imaging. Well designed, large, prospective studies are required to evaluate the accuracy of post-mortem MR imaging, before it can be offered as a clinical tool.

  1. The diagnostic value of axially loaded magnetic resonance imaging in patients with degenerative disorders of lumbar spine

    International Nuclear Information System (INIS)

    Liu Qingyu; Chen Jianyu; Shen Jun; Zhang Xiaoya; Liang Biling

    2008-01-01

    Objective: To evaluate the diagnostic value of axially loaded MR imaging with supine position in patients with degenerative disorders of lumbar spine. Methods Thirty asymptomatic volunteers and 89 patients were examined in psoas-relaxed position (PRP) and axially compressed supine position (ACE) of the lumbar spine. Sixty-one patients with low back pain, 19 with sciatica and 9 with neurogenic claudication were included in the symptomatic study group. The disc levels from L3 to S1 were examined. Results: In 30 asymptomatic volunteers, a significant decrease in dural sac cross-sectional area (DSCA) was found at 14 disc levels (15.6%)in 10 individuals(33.3% ) during ACE ( >15 mm 2 ). In 89 patients, a significant decrease in DSCA was found at 55 disc levels (20.6%) in 38 patients (42.7%) during ACE ( >15 mm 2 ), and the mean decrease was 28 mm 2 . During ACE, 32 disc levels with an increasing severity of disc herniation were noted in 26 patients, 16 disc levels with neural foramen stenosis were found in 12 patients, 11 disc levels with ligamentum flavum thickening were observed in 10 patients, 3 cases facet dislocation and 3 cases lumbar spondylolisthesis were also seen. In 22 of the 89 patients (24.7%), additional valuable information (AVI) was found during ACE, including 7 patients (7/9) with neurogenic claudication, 8 patients (8/19)with sciatica, and 11.5% (7/61) of the patients with low back pain. Conclusion: As compared with conventional imaging methods, axially loaded imaging provides AVI, and more occult lesions can be found during ACE. ACE MRI is a valuable tool in diagnosing degenerative disorders of lumbar spine. (authors)

  2. Magnetic Resonance Imaging

    Science.gov (United States)

    ... Permanent cosmetics or tattoos Dentures/teeth with magnetic keepers Other implants that involve magnets Medication patch (i. ... or longer. You’ll be told ahead of time just how long your scan is expected to ...

  3. Noble gas magnetic resonator

    Science.gov (United States)

    Walker, Thad Gilbert; Lancor, Brian Robert; Wyllie, Robert

    2014-04-15

    Precise measurements of a precessional rate of noble gas in a magnetic field is obtained by constraining the time averaged direction of the spins of a stimulating alkali gas to lie in a plane transverse to the magnetic field. In this way, the magnetic field of the alkali gas does not provide a net contribution to the precessional rate of the noble gas.

  4. Diagnostic performance of fluorodeoxyglucose positron emission tomography/magnetic resonance imaging fusion images of gynecological malignant tumors. Comparison with positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Nakajo, Kazuya; Tatsumi, Mitsuaki; Inoue, Atsuo

    2010-01-01

    We compared the diagnostic accuracy of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and PET/magnetic resonance imaging (MRI) fusion images for gynecological malignancies. A total of 31 patients with gynecological malignancies were enrolled. FDG-PET images were fused to CT, T1- and T2-weighted images (T1WI, T2WI). PET-MRI fusion was performed semiautomatically. We performed three types of evaluation to demonstrate the usefulness of PET/MRI fusion images in comparison with that of inline PET/CT as follows: depiction of the uterus and the ovarian lesions on CT or MRI mapping images (first evaluation); additional information for lesion localization with PET and mapping images (second evaluation); and the image quality of fusion on interpretation (third evaluation). For the first evaluation, the score for T2WI (4.68±0.65) was significantly higher than that for CT (3.54±1.02) or T1WI (3.71±0.97) (P<0.01). For the second evaluation, the scores for the localization of FDG accumulation showing that T2WI (2.74±0.57) provided significantly more additional information for the identification of anatomical sites of FDG accumulation than did CT (2.06±0.68) or T1WI (2.23±0.61) (P<0.01). For the third evaluation, the three-point rating scale for the patient group as a whole demonstrated that PET/T2WI (2.72±0.54) localized the lesion significantly more convincingly than PET/CT (2.23±0.50) or PET/T1WI (2.29±0.53) (P<0.01). PET/T2WI fusion images are superior for the detection and localization of gynecological malignancies. (author)

  5. Injury of the posterior ligamentous complex of the thoracolumbar spine: a prospective evaluation of the diagnostic accuracy of magnetic resonance imaging.

    Science.gov (United States)

    Vaccaro, Alexander R; Rihn, Jeffrey A; Saravanja, Davor; Anderson, David G; Hilibrand, Alan S; Albert, Todd J; Fehlings, Michael G; Morrison, William; Flanders, Adam E; France, John C; Arnold, Paul; Anderson, Paul A; Friel, Brian; Malfair, David; Street, John; Kwon, Brian; Paquette, Scott; Boyd, Michael; Dvorak, Marcel F S; Fisher, Charles

    2009-11-01

    Prospective diagnostic imaging study. To determine the accuracy of magnetic resonance imaging (MRI) in diagnosing injury of the posterior ligamentous complex (PLC) in patients with thoracolumbar trauma. Treatment decisions in thoracolumbar injury patients are currently based on the status of the PLC. It is, therefore, important to understand the accuracy of MRI in diagnosing varying degrees of PLC injury. Prior studies report that MRI is up to 100% sensitive for diagnosing PCL injury. Patients with an acute injury from T1 to L3 who required posterior surgery were prospectively studied. A musculoskeletal radiologist, based on the preoperative MRI findings, characterized each of the 6 components of the PLC as intact, incompletely disrupted, or disrupted. During the surgical procedure, the surgeon identified each component of the PLC as intact, incompletely disrupted, or disrupted. The radiologist's interpretation and surgical findings were compared. Forty-two patients with 62 levels of injury were studied. There were 33 males (78.6%) and 9 females (21.4%), and the average age was 35.7 years. According to the kappa score, there was a moderate level of agreement between the radiologist's interpretation and the intraoperative findings for all PLC components except the thoracolumbar fascia, for which there was slight agreement. The sensitivity for the various PLC components ranged from 79% (left facet capsule) to 90% (interspinous ligament). The specificity ranged from 53% (thoracolumbar fascia) to 65% (ligamentum flavum). There was less agreement between the radiologist and surgeon for the patients with less severe neurologic compromise, i.e., those patients with an AIS grade of either D or E. The sensitivity and specificity of MRI for diagnosing injury of the PLC are lower than previously reported in the literature. The integrity of the PLC as determined by MRI should not be used in isolation to determine treatment.

  6. Diagnostic and prognostic value of right ventricular strain in patients with pulmonary arterial hypertension and relatively preserved functional capacity studied with echocardiography and magnetic resonance.

    Science.gov (United States)

    da Costa Junior, Augusto Alberto; Ota-Arakaki, Jaquelina Sonoe; Ramos, Roberta Pulcheri; Uellendahl, Marly; Mancuso, Frederico José Neves; Gil, Manuel Adan; Fischer, Cláudio Henrique; Moises, Valdir Ambrosio; de Camargo Carvalho, Antonio Carlos; Campos, Orlando

    2017-01-01

    Right ventricular (RV) dysfunction harbingers adverse prognosis in pulmonary arterial hypertension (PAH). Although conventional two-dimensional echocardiography (2DE) is limited for RV systolic function quantitation, RV strain can be a useful tool. The diagnostic and prognostic impact of 2DE speckle-tracking RV longitudinal strain was evaluated, including other 2DE systolic indexes, in a group of PAH patients without severe impairment of functional capacity, chronic pulmonary thromboembolism or left ventricular dysfunction. Sixty-six group I PAH patients, 67 % NYHA functional class I or II (none in IV) were studied by 2DE to obtain: RV fractional area change, tricuspid annular plane systolic excursion, RV myocardial performance index, tissue Doppler tricuspid annulus systolic velocity. Global, free wall (RVFreeWSt) and septal RV longitudinal systolic strain were obtained. RV ejection fraction by cardiac magnetic resonance (CMR-RVEF) was also assessed. All patients were followed up to 3.9 years (mean 3.3 years). Combined endpoints were hospitalization for worsening PAH or cardiovascular death. Among all the 2DE indexes of RV systolic function, RVFreeWSt exhibited the best correlation with CMR-RVEF (r = 0.83; p < 0.005). Combined endpoints occurred in 15 (22.7 %) patients (6 hospitalizations and 9 deaths). Multivariate analysis identified RVFreeWSt ≤-14 % as the only 2DE independent variable associated with combined endpoints [HR 4.66 (1.25-17.37); p < 0.05]. We conclude that RVFreeWSt may be a suitable non-geometric 2DE surrogate of CMR-RVEF in PAH patients, constituting a powerful independent predictor of long-term outcome in this cohort with relatively preserved functional capacity.

  7. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    International Nuclear Information System (INIS)

    Amin, Mohammed Farghally; Youssef, Ahmed Omar

    2012-01-01

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy

  8. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Mohammed Farghally, E-mail: Mohammed_amin37@yahoo.com [Department of Radiodiagnosis ElMinya University, ElMinya High Road, ElMinya (Egypt); Youssef, Ahmed Omar [Department of Orthropedic Surgery El Minya University, ElMinya (Egypt)

    2012-09-15

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy.

  9. Diagnostic value of the nerve root sedimentation sign, a radiological sign using magnetic resonance imaging, for detecting lumbar spinal stenosis: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Liangming; Chen, Ruiqiang; Xie, Peigen; Zhang, Wei; Yang, Yang; Rong, Limin [Sun Yat-Sen University, Department of Spine Surgery, the Third Affiliated Hospital, Guangzhou (China)

    2014-11-28

    This study aimed to determine the diagnostic value of the nerve root sedimentation sign, a relatively new radiological sign using magnetic resonance imaging, for diagnosing lumbar spinal stenosis. The literature search was based on PUBMED, EMBASE, Cochrane Library, Google Scholar, and the Chinese Biomedical Literature Database up to March 2014. A total of 120 articles were identified. Seven studies involving 1,182 patients were included. The quality of the methodology of the seven studies was good. Overall, the pooled weighted value showed that the sedimentation sign had moderate sensitivity of 0.80 [95 % confidence interval (CI) 0.77-0.83] and high specificity of 0.96 (95 % CI 0.94-0.98). The area under the curve was 0.76. Subgroup analysis showed that the degree of morphological spinal stenosis was responsible for the heterogeneity. In the patients with severe morphological lumbar spinal stenosis, the sedimentation sign had even higher sensitivity and specificity: 0.899 (95 % CI 0.87-0.92) and 0.99 (95 % CI 0.98-1.00), respectively. The area under the curve was 0.96. In the patients with lumbar spinal stenosis without definition of morphological stenosis, there was a notable threshold effect and significant heterogeneity. The area under the curve was 0.63. Current evidence suggests that the sedimentation sign has high sensitivity and specificity for diagnosing severe lumbar spinal stenosis. Its performance in diagnosing moderate and mild spinal stenosis, however, has yet to be corroborated in properly designed studies. (orig.)

  10. Fourier transform nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Geick, R.

    1981-01-01

    This review starts with the basic principles of resonance phenomena in physical systems. Especially, the connection is shown between the properties of these systems and Fourier transforms. Next, we discuss the principles of nuclear magnetic resonance. Starting from the general properties of physical systems showing resonance phenomena and from the special properties of nuclear spin systems, the main part of this paper reviews pulse and Fourier methods in nuclear magnetic resonance. Among pulse methods, an introduction will be given to spin echoes, and, apart from the principle of Fourier transform nuclear magnetic resonance, an introduction to the technical problems of this method, e.g. resolution in the frequency domain, aliasing, phase and intensity errors, stationary state of the spin systems for repetitive measurements, proton decoupling, and application of Fourier methods to systems in a nonequilibrium state. The last section is devoted to special applications of Fourier methods and recent developments, e.g. measurement of relaxation times, solvent peak suppression, 'rapid scan'-method, methods for suppressing the effects of dipolar coupling in solids, two-dimensional Fourier transform nuclear magnetic resonance, and spin mapping or zeugmatography. (author)

  11. Magnetic resonance and porous materials

    International Nuclear Information System (INIS)

    McDonald, P.; Strange, J.

    1998-01-01

    Mention the words magnetic resonance to your medical advisor and he or she will immediately think of a multi-million pound scanner that peers deep into the brain. A chemist, on the other hand, will imagine a machine that costs several hundred thousand pounds and produces high-resolution spectra for chemical analysis. Food technologists will probably think of a bench-top instrument for determining moisture content, while an oil prospector will envisage a device that can be operated several kilometres down an oil well. To a physicist the term is more likely to conjure up a mental picture of nuclear spins precessing in a magnetic field. These examples illustrate the diverse aspects of a phenomenon discovered by physicists over 50 years ago. Electron spin resonance was first discovered by Russian scientists, and nuclear magnetic resonance was discovered in the US shortly afterwards by Ed Purcell at Harvard University and Felix Bloch at Stanford University. Today, nuclear magnetic resonance (NMR) is the most widely used technique. Modern NMR machines are making it possible to probe microstructure and molecular movement in materials as diverse as polymers, cements, rocks, soil and foods. NMR allows the distribution of different components in a material to be determined with a resolution approaching 1μm, although the signal can be sensitive to even smaller lengthscales. In this article the authors describe how physicists are still developing magnetic resonance to exploit a range of new applications. (UK)

  12. GHz nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Cross, T.A.; Drobny, G.; Trewhella, J.

    1994-12-01

    For the past dozen years, 500- and 600-MHz spectrometers have become available in many laboratories. The first 600-MHz NMR spectrometer (at Carnegie Mellon University) was commissioned more than 15 years ago and, until 1994, represented the highest field available for high-resolution NMR. This year, we have witnessed unprecedented progress in the development of very high field magnets for NMR spectroscopy, including the delivery of the first commercial 750-MHz NMR spectrometers. In addition, NMR signals have been obtained from 20-Tesla magnets (850 MHz for {sup 1}H`s) at both Los Alamos National Laboratory and Florida State University in the NHMFL (National High Magnetic Field Laboratory). These preliminary experiments have been performed in magnets with 100-ppm homogeneity, but a 20-Tesla magnet developed for the NHMFL will be brought to field this year with a projected homogeneity of 0.1 ppm over a 1-cm-diam spherical volume.

  13. Principles of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mlynarik, V.; Tkac, I.; Srbecky, M.

    1995-01-01

    The aim of this review is to describe and explain the basic principles of magnetic resonance imaging. The first part of the text is devoted to the phenomenon of magnetic resonance (the interaction of RF magnetic field with the set of magnetic moments in the homogeneous magnetic field) and to relaxation processes. Then, the creation of MR image is described (slice selection, phase and frequency encoding of spatial information). The basic and the most frequently used techniques are explained (spin echo, gradient echo). The way the repetition and echo times influence the image quality and contrast (T1 or T2 weighing) is described. The part with the technical description of the MR equipment is included in the review. The MR imagination examination are compared with X-ray computer tomography technique

  14. Diagnostic accuracy of computed tomography and magnetic resonance imaging obtained after neoadjuvant chemoradiotherapy in predicting the local tumor stage and circumferential resection margin status of rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Hoon; Kim, Young Hoon; Lee, Yoon Jin; Lee, Kyoung Ho; Kang, Sung Bum; Kim, Duck Woo; Kim, Jae Hyun; Kim, Jae Sung; Lee, Hye Seung [Dept. of Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); Lee, Sang Min [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2014-02-15

    To measure the diagnostic accuracy of computed tomography (CT) and magnetic resonance imaging (MRI) obtained after neoadjuvant chemoradiotherapy (CRT) in patients with rectal cancer for a prediction of the local tumor stage and circumferential resection margin (CRM). Two independent radiologists reviewed CT and MRI obtained after neoadjuvant CRT. The accuracy of the local tumor staging and the diagnostic performance for the prediction of CRM involvement were calculated. The agreement between the measurements of the distance to potential CRM on both imaging modalities and the histopathology findings was assessed using Bland-Altman plots. 57 patients (mean age, 59.2 years; 24 females) were included. The accuracy of T and N staging were 43.9% (95% confidence interval, 30.8-57.7%) and 77.2% (64.2-87.3%) on CT and 63.2% (49.4-75.6%) and 77.2% (64.2-87.3%) on MRI for Observer 1. The accuracy of T and N staging were 54.4% (40.7-67.7%) and 77.2% (64.2-87.3%) on CT and 68.4% (54.7-80.1%) and 80.7% (68.1-90.0%) on MRI for Observer 2. Sensitivity and specificity on CRM involvement were 83.3% (43.7-97.0%) and 88.2% (76.6-94.5%) on CT and 100% (61.0-100%) and 90.2% (79.0-95.7%) on MRI for Observer 1. Sensitivity and specificity on CRM involvement were 66.7% (30.0-90.3%) and 88.2% (76.7-94.5%) on CT and 100% (61.0-100%) and 90.2% (79.0-95.7%) on MRI for Observer 2. Bland-Altman plots showed wide discrepancies between measurements of the distance to CRM on each CT and MRI and those on histopathology findings. CT and MRI showed limited performance in predicting the local tumor staging and CRM involvement in patients with neoadjuvant CRT although MRI tended to show a better performance than CT.

  15. Diagnostic accuracy of computed tomography and magnetic resonance imaging obtained after neoadjuvant chemoradiotherapy in predicting the local tumor stage and circumferential resection margin status of rectal cancer

    International Nuclear Information System (INIS)

    Park, Jin Hoon; Kim, Young Hoon; Lee, Yoon Jin; Lee, Kyoung Ho; Kang, Sung Bum; Kim, Duck Woo; Kim, Jae Hyun; Kim, Jae Sung; Lee, Hye Seung; Lee, Sang Min

    2014-01-01

    To measure the diagnostic accuracy of computed tomography (CT) and magnetic resonance imaging (MRI) obtained after neoadjuvant chemoradiotherapy (CRT) in patients with rectal cancer for a prediction of the local tumor stage and circumferential resection margin (CRM). Two independent radiologists reviewed CT and MRI obtained after neoadjuvant CRT. The accuracy of the local tumor staging and the diagnostic performance for the prediction of CRM involvement were calculated. The agreement between the measurements of the distance to potential CRM on both imaging modalities and the histopathology findings was assessed using Bland-Altman plots. 57 patients (mean age, 59.2 years; 24 females) were included. The accuracy of T and N staging were 43.9% (95% confidence interval, 30.8-57.7%) and 77.2% (64.2-87.3%) on CT and 63.2% (49.4-75.6%) and 77.2% (64.2-87.3%) on MRI for Observer 1. The accuracy of T and N staging were 54.4% (40.7-67.7%) and 77.2% (64.2-87.3%) on CT and 68.4% (54.7-80.1%) and 80.7% (68.1-90.0%) on MRI for Observer 2. Sensitivity and specificity on CRM involvement were 83.3% (43.7-97.0%) and 88.2% (76.6-94.5%) on CT and 100% (61.0-100%) and 90.2% (79.0-95.7%) on MRI for Observer 1. Sensitivity and specificity on CRM involvement were 66.7% (30.0-90.3%) and 88.2% (76.7-94.5%) on CT and 100% (61.0-100%) and 90.2% (79.0-95.7%) on MRI for Observer 2. Bland-Altman plots showed wide discrepancies between measurements of the distance to CRM on each CT and MRI and those on histopathology findings. CT and MRI showed limited performance in predicting the local tumor staging and CRM involvement in patients with neoadjuvant CRT although MRI tended to show a better performance than CT

  16. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    Energy Technology Data Exchange (ETDEWEB)

    Vasilevskaya, Tatiana M., E-mail: t_vasilevs@mail.ru [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation); Sementsov, Dmitriy I.; Shutyi, Anatoliy M. [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation)

    2012-09-15

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: Black-Right-Pointing-Pointer An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. Black-Right-Pointing-Pointer Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. Black-Right-Pointing-Pointer Both regular and chaotic precession modes are realized within bifurcation resonance range. Black-Right-Pointing-Pointer Appearance of dynamic bistability is typical for bifurcation resonance.

  17. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    International Nuclear Information System (INIS)

    Vasilevskaya, Tatiana M.; Sementsov, Dmitriy I.; Shutyi, Anatoliy M.

    2012-01-01

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: ► An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. ► Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. ► Both regular and chaotic precession modes are realized within bifurcation resonance range. ► Appearance of dynamic bistability is typical for bifurcation resonance.

  18. Magnetic resonance in the diagnostic imaging study of mesial temporal sclerosis; Diagnostico por imagen con resonancia magnetica de la esclerosis temporal mesial

    Energy Technology Data Exchange (ETDEWEB)

    Pastor, E; Sanchez, J C; Rodriguez, I; Altuzarra, A; Machado, F [Hospital Universitario Virgen de las Nieves. Granada (Spain); Aguilar, D [Hospital Clinico Universitario San Cecilio. Granada (Spain)

    2001-07-01

    Mesial temporal sclerosis (MTS) consists of hippocampal atrophy and gliosis and is the most common cause of temporal lobe epilepsy. The objective of the authors was to establish a magnetic resonance imaging (MRI) protocol for its diagnosis. A prospective study was carried out in 72 patients with drug resistant complex partial seizures (42 women and 30 men ranging in age from 6 to 66 year: mean: 30 years). Using a 1.5-Tesla magnet, paracoronal sections were made in hippocampi for T1-weighted inversion-recovery images and volume measurements, fluid-attenuated inversion-recovery (FLAIR) and T2 relaxometry. A control group of 30 health volunteers was included in the study. MTS was considered to be indicated by the presence of atrophy and hyperintensity in hippocampi on T2-weighted images. There were no differences among the hippocampi of the healthy individuals. The confidence intervals (mean{+-} 1.96 SD) were 4169 mm''3-5911 mm''3 for volume of right side, 4097 mm''3-5940 mm''3 for volume of left side and 98-113 ms for T2 relaxation time. MTS was detected in 40 patients (55.5%): 23 cases involving the left side, 13 involving the right and 4 cases of bilateral asymmetric involvement. The 95% confidence intervals for the diagnostic validity of the results (sensitivity/specificity) were (88.8%-97.2%)/(87.6%-96.4%) for T1 volumetry, (88.8%-97.2%)(95.7%-100.3%) for FLAIR and (85.4%-96.6%)/(85.4%-96.6%) for T2 relaxometry. In 5 cases of MTS, astrophy of other extra hippocampal structures was also observed, and MTS was associated with an extra hippocampal lesion (dual pathology), especially neurona migration disorders, in 8 patients. Seventeen patients (23.5%) presented lesions without MTS (tumors, cortical dysplasias and heterotopias) and there was no MRI evidence of anomalies in 15 (21%). Twenty-five patients underwent surgical treatment: 20 with MTS (19 diagnosed according to MRI and one in whom there had been no abnormal findings), 4 with tumors and 1 with a ballooned

  19. Magnetic resonance in the diagnostic imaging study of mesial temporal sclerosis; Diagnostico por imagen con resonancia magnetica de la esclerosis temporal mesial

    Energy Technology Data Exchange (ETDEWEB)

    Pastor, E.; Sanchez, J. C.; Rodriguez, I.; Altuzarra, A.; Machado, F. [Hospital Universitario Virgen de las Nieves. Granada (Spain); Aguilar, D. [Hospital Clinico Universitario San Cecilio. Granada (Spain)

    2001-07-01

    Mesial temporal sclerosis (MTS) consists of hippocampal atrophy and gliosis and is the most common cause of temporal lobe epilepsy. The objective of the authors was to establish a magnetic resonance imaging (MRI) protocol for its diagnosis. A prospective study was carried out in 72 patients with drug resistant complex partial seizures (42 women and 30 men ranging in age from 6 to 66 year: mean: 30 years). Using a 1.5-Tesla magnet, paracoronal sections were made in hippocampi for T1-weighted inversion-recovery images and volume measurements, fluid-attenuated inversion-recovery (FLAIR) and T2 relaxometry. A control group of 30 health volunteers was included in the study. MTS was considered to be indicated by the presence of atrophy and hyperintensity in hippocampi on T2-weighted images. There were no differences among the hippocampi of the healthy individuals. The confidence intervals (mean{+-} 1.96 SD) were 4169 mm''3-5911 mm''3 for volume of right side, 4097 mm''3-5940 mm''3 for volume of left side and 98-113 ms for T2 relaxation time. MTS was detected in 40 patients (55.5%): 23 cases involving the left side, 13 involving the right and 4 cases of bilateral asymmetric involvement. The 95% confidence intervals for the diagnostic validity of the results (sensitivity/specificity) were (88.8%-97.2%)/(87.6%-96.4%) for T1 volumetry, (88.8%-97.2%)(95.7%-100.3%) for FLAIR and (85.4%-96.6%)/(85.4%-96.6%) for T2 relaxometry. In 5 cases of MTS, astrophy of other extra hippocampal structures was also observed, and MTS was associated with an extra hippocampal lesion (dual pathology), especially neurona migration disorders, in 8 patients. Seventeen patients (23.5%) presented lesions without MTS (tumors, cortical dysplasias and heterotopias) and there was no MRI evidence of anomalies in 15 (21%). Twenty-five patients underwent surgical treatment: 20 with MTS (19 diagnosed according to MRI and one in whom there had been no abnormal findings

  20. Recommendations concerning magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    1986-01-01

    In medicine the technique of nuclear magnetic resonance (NMR) is applied in the form of in vivo nuclear magnetic resonance spectroscopy (MRS). In vivo MRS can be carried out non-invasively. The committee of the Dutch Health Council briefly discusses the qualities and potentialities of the nuclei that will probably be used in future clinical spectroscopy: 31 P, 13 C, 1 H (and possibly 19 F and 23 Na). The committee discusses several possibilities of combining imaging and spectroscopy. The imaging of nuclei other than protons is also possible with MRS. Potential applications are considered in oncology, cardiology, neurology and hepatology. (Auth.)

  1. Migraine and magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Younis, Samaira; Hougaard, Anders; Vestergaard, Mark B.

    2017-01-01

    Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation in the meth......Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation...

  2. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Beer, A.; Bielke, G.; Bockenheimer, S.; Brenner, G.; Dieringer, H.; Esswein, H.; Hopf, H.; Koch, H.; Meves, M.; Nagel, F.; Oberstein, A.; Ostheimer, E.; Pfaff, M.; Schlaps, D.; Schopka, H.J.; Seiderer, M.

    1990-01-01

    The study investigates three points of main interest: (1) The clinical efficacy of MR imaging as a routine method, if possible to be assessed in comparison to comparable imaging methods, and referring to a broad spectrum of available types of equipment and modes of operation, to be expressed in terms of diagnostic value and indication of therapy. (2) Specific economic aspects, considering different sites of operation and application conditions. (3) Results of clinical application with regard to individual cases (patient careers), in order to establish a nationwide basis for economic cost-benefit assessment of this diagnostic tool. Another aspect taken into account whenever available data allow so, is substitutional or additional application of MR imaging. The survey is performed on the basis of data accumulated by more than 21.000 MR examinations, and of data describing the application environment, furnished by 25 users from university hospitals, general hospitals, or private practice. (orig./HP) [de

  3. Use of computerized tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tjoerstad, K.

    1992-01-01

    This is a neurologist's opinion on how computerized tomography and magnetic resonance imaging have improved the doctor's diagnostic possibilities, changed patient/doctor relationship and increased the patients' expectations from diagnostic tests. How should the often conflicting interests of patients, society and doctors be handled? 15 refs., 1 fig., 1 tab

  4. The application of magnetic resonance imaging in temporomandibular joint pathology

    International Nuclear Information System (INIS)

    Ehmedov, E.T.; Qahramanov, E.T.

    2007-01-01

    The diseases and damages of temporomandibular joint have compleceted diagnostic unlike other bone-joint pathologies. In 2005 for the first time in history it was implemented the magnetic resonance imaging in diagnostics of patients with with temporomandibular joints pathology. The current researches are in place till today. Being the golden standart the application of magnetic resonance tomography has a great role in differential diagnostics of the chronic arthritis, sclerosanse, deformanse arthrosis and arthrosis with internal derancement. This method guaranteed the correct valuation of the bone, disc and muscle structures of the joint and therefore brought full clearance into the problem

  5. The Standardized Histogram Shift of T2 Magnetic Resonance Image (MRI) Signal Intensities of Nephroblastoma Does Not Predict Histopathological Diagnostic Information

    OpenAIRE

    M?ller, Sabine; David, Ruslan; Marias, Kostas; Graf, Norbert

    2015-01-01

    The objective of this study is to assess standardized histograms of signal intensities of T2-weighted magnetic resonance image (MRI) modality before and after preoperative chemotherapy for nephroblastoma (Wilms? tumor). All analyzed patients are enrolled in the International Society of Paediatric Oncology (SIOP) 2001/GPOH trial.1 The question to be answered is whether the comparison of the histograms can add new knowledge by comparing them with the histology of the tumor after preoperative ch...

  6. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance Imaging Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... about radiology? Share your patient story here Images ... Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  14. An introduction to magnetic resonance in medicine. 2. rev. ed.

    International Nuclear Information System (INIS)

    Rinck, P.A.; Muller, R.N.; Petersen, S.B.

    1990-01-01

    The second edition of this introduction to magnetic resonance in medicine is published five years after the first. During these years, magnetic resonance has established itself as a leading diagnostic modality in medicine. With the introduction of fast imaging methods and contrast agents, magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) have become even more complicated and complex than before. The purpose of this introduction to biomedical MRI and MRS is to give the readers a basic knowledge that will make it possible for them to pursue studies of their own and to cope with some of the most common problems such as image artifacts or patient questions concerning possible hazards of magnetic resonance. (orig./MG) With 99 figs., 11 tabs

  15. Diagnostics of vector magnetic fields

    Science.gov (United States)

    Stenflo, J. O.

    1985-01-01

    It is shown that the vector magnetic fields derived from observations with a filter magnetograph will be severely distorted if the spatially unresolved magnetic structure is not properly accounted for. Thus the apparent vector field will appear much more horizontal than it really is, but this distortion is strongly dependent on the area factor and the temperature line weakenings. As the available fluxtube models are not sufficiently well determined, it is not possible to correct the filter magnetograph observations for these effects in a reliable way, although a crude correction is of course much better than no correction at all. The solution to this diagnostic problem is to observe simultaneously in suitable combinations of spectral lines, and/or use Stokes line profiles recorded with very high spectral resolution. The diagnostic power of using a Fourier transform spectrometer for polarimetry is shown and some results from I and V spectra are illustrated. The line asymmetries caused by mass motions inside the fluxtubes adds an extra complication to the diagnostic problem, in particular as there are indications that the motions are nonstationary in nature. The temperature structure appears to be a function of fluxtube diameter, as a clear difference between plage and network fluxtubes was revealed. The divergence of the magnetic field with height plays an essential role in the explanation of the Stokes V asymmetries (in combination with the mass motions). A self consistent treatment of the subarcsec field geometry may be required to allow an accurate derivation of the spatially averaged vector magnetic field from spectrally resolved data.

  16. Nuclear magnetic resonance (NMR) tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.

    1984-01-01

    A brief survey of the working principle of the NMR technique in diagnostical medicine is given. Its clinical usefulness for locating tumors, diagnosing various other diseases, such as some mental illnesses and multiple sclerosis, and its possibilities for studying biochemical processes in vivo are mentioned. The price of NMR image scanners and the problems of the strong magnetic field around the machines are mentioned

  17. Magnetic Resonance Imaging (MRI): Brain (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Brain KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Brain What's in this article? What ...

  18. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    1997-01-01

    Since 1965, Advances in Magnetic and Optical Resonance has provided researchers with timely expositions of fundamental new developments in the theory of, experimentation with, and application of magnetic and optical resonance.

  19. Magnetic resonance angiography

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Gamroth, A.H.; Schad, L.R.; Semmler, W.; Kaick, G. van; Tuengerthal, S.J.; Hausmann, R.

    1992-01-01

    MR angiography (MRA) proved to be promising combined to MR-Imaging (MRI) in the assessment of intrathoracic masses. Sequential FLASH 2D-angiograms were acquired in breathhold technique using the following parameters: TR=30 ms, TE=10 ms, FA=30deg. Section thickness was 5 mm with 1 mm overlap between sequential sections. Individual conditions of the examination were achieved by an automatised control procedure. Targeted MIP-postprocessing resulted in 3D-reconstructions illustrating vascular anatomy and avoiding superimposition. Presentation should be done by cine-mode for better spatial impression. This method was evaluated in a prospective study of 21 patients with malignant pulmonary and mediastinal masses in addition to spin-echo imaging. The diagnostic contribution concerning the relationship between the mass and the vasculature like displacement, stenosis, and poststenotic perfusion defect were assessed. (orig.) [de

  20. Magnetic resonance for wireless power transfer

    OpenAIRE

    Hui, SYR

    2016-01-01

    Magnetic resonance has been a cornerstone of nonradiative wireless power transfer (WPT) since the late 19th century. However, some researchers have the misconception that magnetic resonance for WPT was developed recently. This article traces some early work of Tesla and other researchers related to the use of magnetic resonance in WPT. Included are some examples of magnetic resonance-based WPT projects conducted by researchers in the biomedical and power electronics communities over the last ...

  1. Lymphoma of uterine cervix: magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kanaan, Daniel; Constantino, Carolina Pesce Lamas; Souza, Rodrigo Canellas de, E-mail: daniel.kanaan@hotmail.com [Department of Radiology, Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Parente, Daniella Braz [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2012-05-15

    Lymphoma of the cervix is a rare disease. About 1.0% to 1.5% of extranodal lymphomas originates in the female genital tract. The clinical presentation of this condition is nonspecific and magnetic resonance imaging is important for diagnostic elucidation. The present report describes the case of a 80-year-old patient with lumbar pain, whose magnetic resonance imaging showed a large uterine mass. The final diagnosis was lymphoma. (author)

  2. Magnetic resonance vs. computerized tomography, ultrasonic examinations and nuclear medicine

    International Nuclear Information System (INIS)

    Bruna, J.

    1985-01-01

    A symposium on magnetic resonance in nuclear medicine was held from 23rd to 27th January, 1985 in Munich and Garmisch-Partenkirchen. Discussed were suitable methods, the use of contrast media, the evaluation of results, the application of nuclear magnetic resonance in examining various body organs, and the latest apparatus. NMR achievements in medicine were compared to those by other diagnostic methods. (M.D.)

  3. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  4. Nanoplatforms for magnetic resonance imaging of cancer

    International Nuclear Information System (INIS)

    Cywinska, M. A.; Grudzinski, I. P.; Cieszanowski, A.; Bystrzejewski, M.; Poplawska, M.

    2011-01-01

    The application of biomedical nanotechnology in magnetic resonance imaging (MRI) is expect to have a major impact leading to the development of new contrast drug candidates on the nanoscale (1 - 100 nm) that are able to react with specific biological targets at a molecular level. One of the major challenges in this regard is the construction of nanomaterials, especially used in molecular MRI diagnostics of cancer in vivo, specialized antitumor drug delivery or real-time evaluation of the efficacy of the implemented cancer treatment. In this paper, we tried to gain further insights into current trends of nanomedicine, with special focus on preclinical MRI studies in translation cancer research. (authors)

  5. Magnetic resonance tomography in syringomyelia

    International Nuclear Information System (INIS)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.; Staedtisches Rudolf-Virchow Krankenhaus, Berlin

    1985-01-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness. (orig.) [de

  6. Limits to magnetic resonance microscopy

    International Nuclear Information System (INIS)

    Glover, Paul; Mansfield, Peter

    2002-01-01

    The last quarter of the twentieth century saw the development of magnetic resonance imaging (MRI) grow from a laboratory demonstration to a multi-billion dollar worldwide industry. There is a clinical body scanner in almost every hospital of the developed nations. The field of magnetic resonance microscopy (MRM), after mostly being abandoned by researchers in the first decade of MRI, has become an established branch of the science. This paper reviews the development of MRM over the last decade with an emphasis on the current state of the art. The fundamental principles of imaging and signal detection are examined to determine the physical principles which limit the available resolution. The limits are discussed with reference to liquid, solid and gas phase microscopy. In each area, the novel approaches employed by researchers to push back the limits of resolution are discussed. Although the limits to resolution are well known, the developments and applications of MRM have not reached their limit. (author)

  7. Magnetic resonance and its applications

    CERN Document Server

    Chizhik, Vladimir I; Donets, Alexey V; Frolov, Vyacheslav V; Komolkin, Andrei V; Shelyapina, Marina G

    2014-01-01

    The book provides a basic understanding of the underlying theory, fundamentals and applications of magnetic resonance The book implies a few levels of the consideration (from simple to complex) of phenomena, that can be useful for different groups of readers The introductory chapter provides the necessary underpinning knowledge for newcomers to the methods The exposition of theoretical materials goes from initial to final formulas through detailed intermediate expressions.

  8. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  9. Magnetic resonance tomography and ultrasound in rheumatology

    International Nuclear Information System (INIS)

    Kainberger, F.; Czerny, C.; Trattnig, S.; Lack, W.; Machold, K.; Graninger, W.

    1996-01-01

    Technical innovations and software improvements in magnetic resonance imaging (MRI) and high-resolution sonography (US) have definitely influenced the diagnostic imaging of rheumatic diseases. For MRI, improvements in surface coils, dedicated low-field systems (0.2 T), and software improvements (shorter acquisition times and refinements of fat suppressing techniques) must be mentioned. For sonography, the main innovations concern the development of higher transducer frequencies (7-15 Mhz) and power Doppler imaging. Clinical evaluations have shown that MRI and US are most useful in cases of suspected rheumatic disease with negative plain film radiographs and for documenting the course of the disease, diagnosing of early rheumatoid arthritis, making a differential diagnosis in clinically unclear rheumatic diseases, investigating vascularization, and quantifying pannus formation. In order to improve diagnostic efficacy the role of MRI and US in the management of patients with rheumatic disease should be reconsidered. (orig.) [de

  10. Shimadzu magnetic resonance imaging system, SMT-50

    International Nuclear Information System (INIS)

    Oikawa, Shiro; Nishida, Takayuki; Fujio, Yasuo

    1986-01-01

    The magnetic resonance imaging (MRI) system, as a new modality of medical imaging, has already been put to practical applications on many clinical sites, through which a lot of clinical data has been accumulated. It can offer a powerful new probe of internal anatomy of the human body and its functions. Now that the MRI has established its effectiveness in diagnosis, a really practical MRI system which features high efficiency and economical design with high patient throughput is strongly called for. Introduced in this article is a superconductive magnet MRI system, SMT-50, operating at 5000 Gauss. It has realized an excellent diagnostic capability with such functions as multi-slice multi-echo imaging, high sensitive, surface coil technique and so on. High resolution image display (1024 x 1024 pixcel) unit and separate console system (viewing console and scanning console) will assist high patient throughput. The outline of the SMT-50 and its clinical data are reported here. (author)

  11. The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement

    Energy Technology Data Exchange (ETDEWEB)

    Crespo-Rodríguez, Ana M., E-mail: anacresporodriguez@gmail.com [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); De Lucas-Villarrubia, Jose C., E-mail: jclucasv@hotmail.com [Department of Orthopaedics and Traumatology at the Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Pastrana-Ledesma, Miguel, E-mail: m.pastrana@telefonica.net [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Hualde-Juvera, Ana, E-mail: ana.hualdej@salud.madrid.org [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Méndez-Alonso, Santiago, E-mail: smendez.sma@gmail.com [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Padron, Mario, E-mail: mario.padron@clinicacemtro.com [Department of Radiology, Clínica Cemtro, Avda Ventisquero de la Condesa 42 Madrid 28035, Madrid (Spain)

    2017-03-15

    Highlights: • High resolution sequences at 3-T MRI extend accuracy in hip assessment without any need for intra-articular injection of contrast media. • As compared to 1.5-T MRA, 3-T non-contrast MRI of the hip improves the patient experience and avoids the potential risks of an invasive procedure and contrast media. • Avoiding the need for arthrographic procedures in the Radiology Department improves patient throughput and reduces costs. - Abstract: Objective: The aim of this study was to evaluate the diagnostic accuracy of 3-T non-contrast MRI versus 1.5-T MRA for assessing labrum and articular cartilage lesions in patients with clinical suspicion of femoro-acetabular impingement (FAI). Subjects and methods: Fifty patients (thirty men and twenty women, mean age 42.5 years) underwent 1.5-T MRA, 3-T MRI and arthroscopy on the same hip. An optimized high-resolution proton density spin echo pulse sequence was included in the 3-T non-contrast MRI protocol. Results: The 3-T non-contrast MRI identified forty-two of the forty-three arthroscopically proven tears at the labral-chondral transitional zone (sensitivity, 97.7%; specificity, 100%; positive predictive value (PPV), 100%; negative predictive value (NPV), 87.5%; accuracy 98%). With 1.5-T MRA, forty-four tears were diagnosed. However, there was one false positive (sensitivity, 100%; specificity, 85.7%; PPV, 97.7%; NPV, 100%; accuracy 98%). Agreement between arthroscopy and MRI, whether 3-T non-contrast MRI or 1.5-T MRA, as to the degree of chondral lesion in the acetabulum was reached in half of the patients and in the femur in 76% of patients. Conclusion: Non-invasive assessment of the hip is possible with 3-T MR magnet. 3-T non-contrast MRI could replace MRA as the workhorse technique for assessing hip internal damage. MRA would then be reserved for young adults with a strong clinical suspicion of FAI but normal findings on 3-T non-contrast MRI. When compared with 1.5-T MRA, optimized sequences with 3-T non

  12. The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement

    International Nuclear Information System (INIS)

    Crespo-Rodríguez, Ana M.; De Lucas-Villarrubia, Jose C.; Pastrana-Ledesma, Miguel; Hualde-Juvera, Ana; Méndez-Alonso, Santiago; Padron, Mario

    2017-01-01

    Highlights: • High resolution sequences at 3-T MRI extend accuracy in hip assessment without any need for intra-articular injection of contrast media. • As compared to 1.5-T MRA, 3-T non-contrast MRI of the hip improves the patient experience and avoids the potential risks of an invasive procedure and contrast media. • Avoiding the need for arthrographic procedures in the Radiology Department improves patient throughput and reduces costs. - Abstract: Objective: The aim of this study was to evaluate the diagnostic accuracy of 3-T non-contrast MRI versus 1.5-T MRA for assessing labrum and articular cartilage lesions in patients with clinical suspicion of femoro-acetabular impingement (FAI). Subjects and methods: Fifty patients (thirty men and twenty women, mean age 42.5 years) underwent 1.5-T MRA, 3-T MRI and arthroscopy on the same hip. An optimized high-resolution proton density spin echo pulse sequence was included in the 3-T non-contrast MRI protocol. Results: The 3-T non-contrast MRI identified forty-two of the forty-three arthroscopically proven tears at the labral-chondral transitional zone (sensitivity, 97.7%; specificity, 100%; positive predictive value (PPV), 100%; negative predictive value (NPV), 87.5%; accuracy 98%). With 1.5-T MRA, forty-four tears were diagnosed. However, there was one false positive (sensitivity, 100%; specificity, 85.7%; PPV, 97.7%; NPV, 100%; accuracy 98%). Agreement between arthroscopy and MRI, whether 3-T non-contrast MRI or 1.5-T MRA, as to the degree of chondral lesion in the acetabulum was reached in half of the patients and in the femur in 76% of patients. Conclusion: Non-invasive assessment of the hip is possible with 3-T MR magnet. 3-T non-contrast MRI could replace MRA as the workhorse technique for assessing hip internal damage. MRA would then be reserved for young adults with a strong clinical suspicion of FAI but normal findings on 3-T non-contrast MRI. When compared with 1.5-T MRA, optimized sequences with 3-T non

  13. The nuclear magnetic resonance well logging

    International Nuclear Information System (INIS)

    Zhang Yumin; Shen Huitang

    2003-01-01

    In this paper, the characteristic of the nuclear magnetic resonance logging is described at first. Then its development and its principle is presented. Compared with the nuclear magnetic resonance spectrometer, the magnet techniques is the first question that we must solve in the manufacture of the NMR well logging

  14. Magnetic resonance imaging as a diagnostic method for assessing function. New procedures for the non-invasive quantification of cerebral blood volume and blood flow

    International Nuclear Information System (INIS)

    Gueckel, F.; Rempp, K.; Becker, G.; Koepke, J.; Loose, R.; Brix, G.

    1994-01-01

    This paper presents a brief introduction to the current status of cerebral blood volume and blood flow imaging with magnetic resonance imaging (MRI) techniques. A new method for the quantitative assessment of regional cerebral blood volume (rCBV) and regional cerebral blood flow (rCBF) on the basis of the indicator dilution theory is described and preliminary quantitative results from healthy volunteers are presented. The mean values for the rCBV are 8,27±1,85 ml/100 g for grey matter and 3,78±1,34 ml/100 g for white matter. The mean values for the rCBF are 44,8±11,29 ml/min/100 g for the grey matter and 20,88±8,42 ml/min/100 g for the white matter. These results are in good agreement with PET results from the literature. (orig.) [de

  15. Magnetic resonance imaging at Rikshospitalet

    International Nuclear Information System (INIS)

    Smith, H.J.

    1990-01-01

    During the first 18 months of operations of the nuclear magnetic resonance (NMR) unit at Rikshospitalet, 1453 NMR examinations have been performed on 1431 patients. 64% of the time has been devoted to examinations of the central nervous system and spine in children and adults, 9% of the time has been used on non-neuroradiology pediatric patients, while the rest of the time has been spent equally on ear, nose and throat, thoracic (including cardiac) and abdominal examinations in adult patients. The indications for doing NMR at Rikshospitalet are listed and discussed, and it is concluded that NMR has proved to be useful at several conditions in most organ systems. 15 refs

  16. Advances in magnetic resonance 3

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 3, describes a number of important developments which are finding increasing application by chemists. The book contains five chapters and begins with a discussion of how the properties of random molecular rotations reflect themselves in NMR and how they show up, often differently, in other kinds of experiments. This is followed by separate chapters on the Kubo method, showing its equivalence to the Redfield approach in the cases of most general interest; the current state of dynamic nuclear polarization measurements in solutions and what they tell us abou

  17. Resonant and nonresonant magnetic scattering (invited)

    International Nuclear Information System (INIS)

    McWhan, D.B.; Hastings, J.B.; Kao, C.; Siddons, D.P.

    1992-01-01

    The tunability and the polarization of synchrotron radiation open up new possibilities for the study of magnetism. Studies on magnetic materials performed at the National Synchrotron Light Source are reviewed, and they fall into four areas: structure, evolution of magnetic order, separation of L and S, and resonance effects. In the vicinity of atomic absorption edges, the Faraday effect, magnetic circular dichroism, and resonant magnetic scattering are all related resonance effects which measure the spin-polarized density of states. The production and analysis of polarized beams are discussed in the context of the study of magnetism with synchrotron radiation

  18. Magnetic resonance imaging in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.; Paprzycki, W.

    1993-01-01

    In the paper authors describe fundamental physical properties of a phenomenon of the radio-frequency excitation and relaxation of nuclei ordered in a strong magnetic field and the usefulness of MRI in medical diagnostic procedures. Basic interpretations principles of MR imaging due to signal intensity differences between organs and tissues in T 1 - and T 2 - weighted sequences and proton density are presented. Both, literature review and experience of authors suggest application of MRI in otolaryngology, it is illustrated by a lot of examples. The MR imaging studies were compared with results obtained from CT in otolaryngology field. (author)

  19. Tunable Magnetic Resonance in Microwave Spintronics Devices

    Science.gov (United States)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  20. Migraine and magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Younis, Samaira; Hougaard, Anders; Vestergaard, Mark B.

    2017-01-01

    Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation in the meth......Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation...... in the methodology and quality of the MRS migraine studies over time, some results were consistent and reproducible. 31P-MRS studies suggested reduced availability of neuronal energy and implied a mitochondrial dysfunction in the migraine brain. 1H-MRS studies reported interictal abnormalities in the excitatory...... and inhibitory neurotransmitters, glutamate and g-aminobutyric acid (GABA), suggesting persistent altered excitability in migraine patients. N-Acetylaspartate levels were decreased in migraine, probably due to a mitochondrial dysfunction and abnormal energy metabolism. The reported abnormalities may increase...

  1. Magnetic resonance imaging of chemistry.

    Science.gov (United States)

    Britton, Melanie M

    2010-11-01

    Magnetic resonance imaging (MRI) has long been recognized as one of the most important tools in medical diagnosis and research. However, MRI is also well placed to image chemical reactions and processes, determine the concentration of chemical species, and look at how chemistry couples with environmental factors, such as flow and heterogeneous media. This tutorial review will explain how magnetic resonance imaging works, reviewing its application in chemistry and its ability to directly visualise chemical processes. It will give information on what resolution and contrast are possible, and what chemical and physical parameters can be measured. It will provide examples of the use of MRI to study chemical systems, its application in chemical engineering and the identification of contrast agents for non-clinical applications. A number of studies are presented including investigation of chemical conversion and selectivity in fixed-bed reactors, temperature probes for catalyst pellets, ion mobility during tablet dissolution, solvent dynamics and ion transport in Nafion polymers and the formation of chemical waves and patterns.

  2. Impact of magnetic resonance urography and ultrasonography on ...

    African Journals Online (AJOL)

    Background: (1) To evaluate the diagnostic value of magnetic resonance urography (MRU) in comparison with ultrasonography (US) to determine the extent of upper urinary tract dilation and (2) to evaluate the impact of MRU on therapy management. Materials and Methods: From January 2005 to December 2010, ...

  3. Advances in mechanical detection of magnetic resonance

    International Nuclear Information System (INIS)

    Kuehn, Seppe; Hickman, Steven A.; Marohn, John A.

    2008-01-01

    The invention and initial demonstration of magnetic resonance force microscopy (MRFM) in the early 1990s launched a renaissance of mechanical approaches to detecting magnetic resonance. This article reviews progress made in MRFM in the last decade, including the demonstration of scanned probe detection of magnetic resonance (electron spin resonance, ferromagnetic resonance, and nuclear magnetic resonance) and the mechanical detection of electron spin resonance from a single spin. Force and force-gradient approaches to mechanical detection are reviewed and recent related work using attonewton sensitivity cantilevers to probe minute fluctuating electric fields near surfaces is discussed. Given recent progress, pushing MRFM to single proton sensitivity remains an exciting possibility. We will survey some practical and fundamental issues that must be resolved to meet this challenge.

  4. Magnetic resonance imaging: hazard, risk and safety

    International Nuclear Information System (INIS)

    Narayan, Pradeep; Suri, S.; Singh, P.

    2001-01-01

    The hazard and risk associated with magnetic resonance imaging is a matter of concern. In 1982, the Food and Drug Administration (FDA), USA issued guidelines to Hospital's Investigational Review Board (IRBs) in 'Guidelines for Evaluating Electromagnetic Exposure Risks for Trials of Clinical Nuclear Magnetic Resonance (NMR)'. In 1997, the Berufsgenossenschaft (BG), professional association for precision engineering and electronics of Germany, in their preliminary proposal for safety limits extended their concerns on static magnetic field. Owing to both time varying and static magnetic fields applied in Magnetic Resonance Imaging (MRI) this became of immediate concern to user community to assess the potential hazard and risk associated with the NMR system

  5. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Nakamura, Yusaku; Takahashi, Mitsuo; Kitaguchi, Masataka; Akaneya, Yukio; Mitui, Yoshiyuki; Tanaka, Hisashi

    1991-01-01

    We studied eighteen patients affected by Parkinsonism with symptoms of tremor, bradykinesia, or rigidity using magnetic resonance imaging (MRI). Patients ranged in age from 34 to 80 years (mean 62.8±11.6 years), and the duration of their disease had been 3.8±3.2 years. MRI examinations were performed with Shimazu and Siemens superconducting magnets, operating at 0.5 and 1.5 T magnetic fields, respectively. Both T 1 - and T 2 -weighted spin echo (SE) pulse sequences were used. In eight patients (44.4%), MRI demonstrated bilateral multiple lacunar infarction of the basal ganglia. The most common abnormality identified was multiple, bilateral lacunar infarcts in the lateral portion of the putamen. The average size of the lacunar infarction of the putamen was less than half that of the entire putamen. Patients with multiple lacunar infarction were significantly older than the other patients and had lower Yahr's scores. The clinical symptoms of patients with bilateral multiple lacunar infarction of the basal ganglia were compatible with the diagnosis of arteriosclerotic Parkinsonism of akinetic rigid type. It has been suggested that multiple lacunar infarction of the basal ganglia may have led to Parkinsonism in these patients. (author)

  6. Nuclear magnetic resonance imaging method

    International Nuclear Information System (INIS)

    Johnson, G.; MacDonald, J.; Hutchison, S.; Eastwood, L.M.; Redpath, T.W.T.; Mallard, J.R.

    1984-01-01

    A method of deriving three dimensional image information from an object using nuclear magnetic resonance signals comprises subjecting the object to a continuous, static magnetic field and carrying out the following set of sequential steps: 1) exciting nuclear spins in a selected volume (90deg pulse); 2) applying non-aligned first, second and third gradients of the magnetic field; 3) causing the spins to rephase periodically by reversal of the first gradient to produce spin echoes, and applying pulses of the second gradient prior to every read-out of an echo signal from the object, to differently encode the spin in the second gradient direction for each read-out signal. The above steps 1-3 are then successively repeated with different values of gradient of the third gradient, there being a recovery interval between the repetition of successive sets of steps. Alternate echoes only are read out, the other echoes being time-reversed and ignored for convenience. The resulting signals are appropriately sampled, set out in an array and subjected to three dimensional Fourier transformation. (author)

  7. Nuclear magnetic resonance in cardiology: cardiac MRI

    International Nuclear Information System (INIS)

    Fernandez, Claudio C.

    2003-01-01

    As a new gold standard for mass, volume and flow, the magnetic resonance imaging (MRI) is probably the most rapidly evolving technique in the cardiovascular diagnosis. An integrated cardiac MRI examination allows the evaluation of morphology, global and regional function, coronary anatomy, perfusion, viability and myocardial metabolism, all of them in only one diagnostic test and in a totally noninvasive manner. The surgeons can obtain relevant information on all aspects of diseases of the heart and great vessels, which include anatomical details and relationships with the greatest field of view, and may help to reduce the number of invasive procedures required in pre and postoperative evaluation. However, despite these excellent advantages the present clinical utilization of MRI is still too often restricted to few pathologies or case studies in which other techniques fail to identify the cardiac or cardiovascular abnormalities. If magnetic resonance is an excellent method for diagnosing so many different cardiac conditions, why is so little it used in routine cardiac practice? Cardiologists are still not very familiar with the huge possibilities or cardiovascular MRI utilities. Our intention is to give a comprehensive survey of many of the clinical applications of this challenger technique in the study of the heart and great vessels. Those who continue to ignore this important and mature imaging technique will rightly fail to benefit. (author) [es

  8. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    International Nuclear Information System (INIS)

    Braggion-Santos, Maria Fernanda; Koenigkam-Santos, Marcel; Teixeira, Sara Reis; Volpe, Gustavo Jardim; Trad, Henrique Simão; Schmidt, André

    2013-01-01

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility

  9. Magnetic resonance, a phenomenon with a great potential in medicine, but with a complex physical background – Part 2: The basics of magnetic resonance

    Directory of Open Access Journals (Sweden)

    Bojan Božič

    2014-01-01

    Full Text Available Magnetic resonance imaging is a very complex diagnostic technique. Therefore, both practical experiences and theoretical understanding is needed for effective diagnostics. It is therefore important that physicians are sufficiently familiar with the basic physical principles of magnetic resonance. In the interpretation of physical concepts, we will rely both on the classical as well as on the quantum-mechanical view of the signal formation in magnetic resonance, which are to some extent complementary. The signal appearance in magnetic resonance imaging will be discussed. A special emphasis will be put on the role of the resonance frequency and the pulse sequences. Furthermore, the spin echo as one of the most used classical signal sequences in diagnostic investigations will be described.

  10. Magnetic resonance angiography in suspected cerebral vasculitis

    International Nuclear Information System (INIS)

    Demaerel, Philippe; De Ruyter, Nele; Wilms, Guido; Maes, Frederik; Velghe, Beatrijs

    2004-01-01

    The purpose of this study was to determine the technical capacity and diagnostic accuracy of 3D time-of-flight magnetic resonance angiography (MRA) in suspected cerebral vasculitis in a retrospective analysis of MRA and digital subtraction angiography (DSA) in 14 young patients with clinical and/or radiological suspicion of cerebral vasculitis. A total of nine arteries were evaluated in each patient. Consensus review of DSA by three observers was the reference standard. The sensitivity for detecting a stenosis varied from 62 to 79% for MRA and from 76 to 94% for DSA, depending on the observer. The specificity for detecting a stenosis varied from 83 to 87% for MRA and from 83 to 97% for DSA. Using the criterion ''more than two stenoses in at least two separate vascular distributions'' to consider the examination as being true positive, the false-positive rates for MRA and DSA were comparable. MRA plays a role as the first angiographical examination in the diagnostic work-up of suspected cerebral vasculitis. When more than two stenoses in at least two separate vascular distributions are depicted on MRA, DSA is not expected to add a significant diagnostic contribution in a patient with suspected cerebral vasculitis. DSA remains necessary when MRA is normal or when less than three stenoses are seen. (orig.)

  11. Magnetic resonance angiography in suspected cerebral vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Demaerel, Philippe; De Ruyter, Nele; Wilms, Guido [Department of Radiology, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Maes, Frederik [Department of Medical Imaging Computing, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Velghe, Beatrijs [Department of Radiology, Ziekenhuis Oost-Limburg, Schiepse Bos 6, 3600, Genk (Belgium)

    2004-06-01

    The purpose of this study was to determine the technical capacity and diagnostic accuracy of 3D time-of-flight magnetic resonance angiography (MRA) in suspected cerebral vasculitis in a retrospective analysis of MRA and digital subtraction angiography (DSA) in 14 young patients with clinical and/or radiological suspicion of cerebral vasculitis. A total of nine arteries were evaluated in each patient. Consensus review of DSA by three observers was the reference standard. The sensitivity for detecting a stenosis varied from 62 to 79% for MRA and from 76 to 94% for DSA, depending on the observer. The specificity for detecting a stenosis varied from 83 to 87% for MRA and from 83 to 97% for DSA. Using the criterion ''more than two stenoses in at least two separate vascular distributions'' to consider the examination as being true positive, the false-positive rates for MRA and DSA were comparable. MRA plays a role as the first angiographical examination in the diagnostic work-up of suspected cerebral vasculitis. When more than two stenoses in at least two separate vascular distributions are depicted on MRA, DSA is not expected to add a significant diagnostic contribution in a patient with suspected cerebral vasculitis. DSA remains necessary when MRA is normal or when less than three stenoses are seen. (orig.)

  12. Magnetic resonance arthrography in chronic wrist pain

    International Nuclear Information System (INIS)

    Valeri, G.; Ferrara, C.; Carloni, S.

    1999-01-01

    The purpose of this paper is to investigate the clinical role of Magnetic Resonance Arthrography (MRA) of the wrist in subjects with chronic pain. Thirty-five patients complaining of wrist pain for more than 6 months were submitted to MRI an MRA. All patients received and intra-articular injection of 2-10 mL of a 10 mmol saline solution of Gd-DPTA. The overall diagnostic accuracy rates of MRI and MRA were 40% and 81% respectively, with sensitivity and specificity of 63% and 39% (MRI) and of 82% and 79% (MRA). The conclusion is that compared with MRI, MRA can be considered a useful tool for the visualization of interosseus carpal ligaments and of the triangular fibrocartilage complex. MRA also helps detect injuries in these structures [it

  13. Cardiovascular magnetic resonance in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Shiozaki, Afonso Akio; Parga, Jose Rodrigues; Arteaga, Edmundo; Rochitte, Carlos Eduardo; Tassi, Eduardo Marinho

    2007-01-01

    Hypertrophic cardiomyopathy (HCM) is the most frequent genetic cardiac disease that causes sudden death in young people, with an incidence of 1:500 adults. The routinely used criteria for worst prognosis have limited sensitivity and specificity. Thus, the estimated risk of evolving to dilated cardiomyopathy or sudden death is somewhat inaccurate, leading to management uncertainty of HCM patients. Therefore, an accurate noninvasive method for the diagnosis of HCM with prognostic value is of great importance. In the last years, Cardiovascular Magnetic Resonance (CMR) emerged not only as a diagnostic tool, but also as a study with prognostic values, by characterizing myocardial fibrosis with great accuracy in HCM patients. Additionally, CMR identifies the types of hypertrophy, analyses the ventricular function, estimates the intraventricular gradient and allows the determination of differential diagnosis. Moreover, CMR can uniquely access myocardial fibrosis in HCM. (author)

  14. Magnetic resonance imaging in pediatric neurological disease

    International Nuclear Information System (INIS)

    Tsukiyama, Takashi; Nishimoto, Hiroshi; Fujioka, Mutsuhisa; Aihara, Toshinori; Tanaka, Osamu.

    1986-01-01

    In this paper, we summarize our initial experience with Magnetic Resonance Imaging(MRI) in the evaluation of pediatric neurological disease. 17 children between the ages of 2 month and 8.5 year have been examined with MRI. All subjects tolerated the MRI procedure well, although sedation was necessary for young children. Result as follows : (1) MRI does not utilize ionising radiation to produce an image. (2) MRI images more clearly demonstrate cerebral gray and white matter than X-ray CT. (3) Compared with X-ray CT, MRI proved to be advantageous in detection and characterization of the pathology, especially when the abnormality was located along the posterior fossa and spinal canal. It is suggested that these nature of MRI makes it the ideal diagnostic method for children. (author)

  15. Chest magnetic resonance imaging: a protocol suggestion

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-12-01

    Full Text Available Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.

  16. Magnetic resonance imaging of hypothalamic hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Kanazawa, Junichi; Uozumi, Tohru; Sakoda, Katsuaki; Yamanaka, Masami; Kihara, Mikio; Nishi, Yoshikazu; Kagawa, Yoshihiro; Kajima, Toshio.

    1988-05-01

    Magnetic resonance (MR) findings of two patients with a hypothalamic hamartoma are discussed. The two girls showed clinical symptoms and endocrinological signs of precocious puberty. MR imaging was of diagnostic value superior to that of CT in the demonstration of the characteristic location of this tumor and relationships to the neighboring structures because of its multi-dimensional utility. Although it has been reported that CT showed this lesion as isodense to the grey matter with and without injection of contrast medium, MR imaging depicted the lesion as a high signal intensity area on T2-weighted images in both patients. MR imaging is a useful method for the evaluation of the hypothalamic hamartoma.

  17. Diagnostic performance of susceptibility-weighted magnetic resonance imaging for the assessment of sub-coracoacromial spurs causing subacromial impingement syndrome.

    Science.gov (United States)

    Nörenberg, Dominik; Armbruster, Marco; Bender, Yi-Na; Walter, Thula; Ebersberger, Hans U; Diederichs, Gerd; Hamm, Bernd; Ockert, Ben; Makowski, Marcus R

    2017-03-01

    To evaluate the potential of susceptibility-weighted-magnetic-resonance-imaging (SWMR) for the detection of sub-coracoacromial spurs in patients with clinically suspected subacromial impingement syndrome (SAIS), compared to standard MR-sequences and radiographs. Forty-four patients with suspected SAIS were included. All patients underwent radiography, standard MRI of the shoulder and SWMR. Radiograph-based identification of sub-coracoacromial spurs served as goldstandard. Radiographs identified twenty-three spurs in twenty-three patients. Twenty-one patients without spur formation served as reference group. Detection rate, sensitivity/specificity and interobserver-agreements were calculated. Linear regression was applied to determine the relationship between size measurements on radiographs and MRI. Detection rates for spurs on standard MRI and SWMR were 47.8 % and 91.3 % compared to radiography (pformation in patients with SAIS and is superior to standard MR-sequences using radiography as goldstandard. • SWMR has the potential to reliably identify sub-coracoacromial spurs without radiation exposure. • SWMR provides comparable detection rates to conventional radiography for sub-coracoacromial spur formation. • SWMR yields higher detection rates compared to standard-MR regarding sub-coracoacromial spur formation. • SWMR can be implemented in routine shoulder MRI protocols.

  18. Transition metal nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Pregosin, P.S.

    1991-01-01

    Transition metal NMR spectroscopy has progressed enormously in recent years. New methods, and specifically solid-state methods and new pulse sequences, have allowed access to data from nuclei with relatively low receptivities with the result that chemists have begun to consider old and new problems, previously unapproachable. Moreover, theory, computational science in particular, now permits the calculation of not just 13 C, 15 N and other light nuclei chemical shifts, but heavy main-group element and transition metals as well. These two points, combined with increasing access to high field pulsed spectrometer has produced a wealth of new data on the NMR transition metals. A new series of articles concerned with measuring, understanding and using the nuclear magnetic resonance spectra of the metals of Group 3-12 is presented. (author)

  19. Gaucher's disease: Magnetic resonance findings

    International Nuclear Information System (INIS)

    Roca, M.; Gomez-Pereda, R.; Blasco, A.; Ros, L.

    1996-01-01

    The objective is to assess the role of magnetic resonance (MR) in determining the initial extension of Gaucher's disease and its complications. A retrospective study of eight patients diagnosed as having Gaucher's disease was carried out using MR. The study focused on pelvis, hip, femur, spine, liver parenchyma and splenic parenchyma. Infiltration of the cancellous portion of the vertebral bodies was observed in all but one of the patients. Three patients presented small hemangiomas in dorsal and lumbar vertebral bodies. Pelvic bone involvement was homogeneous in four cases and spotty in two, while the pelvic marrow was normal in the two patients with no vertebral infiltration. A vascular necrosis of the femoral head was detected in two cases. MR is very useful in determining the initial extension, in the early diagnosis of complications and in managing the posttreatment marrow response to assess the therapeutic efficacy. 16 refs

  20. Fetal abdominal magnetic resonance imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Prayer, Daniela

    2006-01-01

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages

  1. Fetal abdominal magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages.

  2. Magnetic resonance imaging in neuroradiology

    International Nuclear Information System (INIS)

    Voigt, K.; Lotx, J.W.

    1990-01-01

    Magnetic resonance imaging (MRI) is now accepted as an effective method of investigating a wide range of disorders, especially of the brain and spine. A short introduction on image contrast in MRI is given and the advantages and disadvantages for the different diseases of the brain is discussed. Excellent soft-tissue contrast, multiplanar imaging capabilities and lack of ionising radiation are conspicuous advantages, and it is now established as the investigation of choice in a large number of clinical conditions, especially when the central nervous system is involved. However, it remains only one of a series of imaging modalities. A confident provisional clinical diagnosis is essential for establishing an imaging protocol and the intention should always be to reach a definitive diagnosis in the least invasive and most cost-effective way. 7 figs., 19 refs

  3. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  4. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  5. Magnetic resonance imaging of radiation optic neuropathy

    International Nuclear Information System (INIS)

    Zimmerman, C.F.; Schatz, N.J.; Glaser, J.S.

    1990-01-01

    Three patients with delayed radiation optic neuropathy after radiation therapy for parasellar neoplasms underwent magnetic resonance imaging. The affected optic nerves and chiasms showed enlargement and focal gadopentetate dimeglumine enhancement. The magnetic resonance imaging technique effectively detected and defined anterior visual pathway changes of radionecrosis and excluded the clinical possibility of visual loss because of tumor recurrence

  6. Magnetic resonance: discovery, investigations, and applications

    International Nuclear Information System (INIS)

    Kessenikh, Aleksandr V

    2009-01-01

    The history of the development of the theoretical ideas and experimental methods of magnetic resonance, as well as the applications of these methods in modern natural science, technology, and medicine, are outlined, with allowance for the contribution of Russian researchers. An assessment of some promising trends of studies and applications of magnetic resonance is given. (from the history of physics)

  7. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  8. Multidimensionally encoded magnetic resonance imaging.

    Science.gov (United States)

    Lin, Fa-Hsuan

    2013-07-01

    Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled. Copyright © 2012 Wiley Periodicals, Inc.

  9. Diagnostic performance of susceptibility-weighted magnetic resonance imaging for the assessment of sub-coracoacromial spurs causing subacromial impingement syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Noerenberg, Dominik; Armbruster, Marco [Munich University Hospitals Campus Grosshadern, Department of Clinical Radiology, Munich (Germany); Bender, Yi-Na; Walter, Thula; Diederichs, Gerd; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Ebersberger, Hans U. [Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Ockert, Ben [Munich University Hospitals Campus Grosshadern, Department of Trauma and Orthopedic Surgery, Shoulder and Elbow Service, Munich (Germany); Makowski, Marcus R. [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2017-03-15

    To evaluate the potential of susceptibility-weighted-magnetic-resonance-imaging (SWMR) for the detection of sub-coracoacromial spurs in patients with clinically suspected subacromial impingement syndrome (SAIS), compared to standard MR-sequences and radiographs. Forty-four patients with suspected SAIS were included. All patients underwent radiography, standard MRI of the shoulder and SWMR. Radiograph-based identification of sub-coracoacromial spurs served as goldstandard. Radiographs identified twenty-three spurs in twenty-three patients. Twenty-one patients without spur formation served as reference group. Detection rate, sensitivity/specificity and interobserver-agreements were calculated. Linear regression was applied to determine the relationship between size measurements on radiographs and MRI. Detection rates for spurs on standard MRI and SWMR were 47.8 % and 91.3 % compared to radiography (p<0.001). SWMR demonstrated a sensitivity of 97.7 % (CI=0.92-1) and a specificity of 91.3 % (CI=0.788-1) for the identification of spurs. Standard MR-sequences achieved a sensitivity of 47.8 % (CI=0.185-0.775) and a specificity of 80.8 % (CI=0.642-0.978). Size measurements between SWMR and radiography showed a good correlation (R{sup 2}=0.75;p<0.0001), while overestimating lesion size (5.7±1.2 mm; 4.3±1.3 mm;p<0.0001). Interobserver-agreement for spurs was high on SWMR (R{sup 2}=0.74;p<0.0001), but low on standard MRI (R{sup 2}=0.24;p<0.0001). SWMR allows a reliable detection of sub-coracoacromial spur formation in patients with SAIS and is superior to standard MR-sequences using radiography as goldstandard. (orig.)

  10. Diagnostic performance of susceptibility-weighted magnetic resonance imaging for the assessment of sub-coracoacromial spurs causing subacromial impingement syndrome

    International Nuclear Information System (INIS)

    Noerenberg, Dominik; Armbruster, Marco; Bender, Yi-Na; Walter, Thula; Diederichs, Gerd; Hamm, Bernd; Ebersberger, Hans U.; Ockert, Ben; Makowski, Marcus R.

    2017-01-01

    To evaluate the potential of susceptibility-weighted-magnetic-resonance-imaging (SWMR) for the detection of sub-coracoacromial spurs in patients with clinically suspected subacromial impingement syndrome (SAIS), compared to standard MR-sequences and radiographs. Forty-four patients with suspected SAIS were included. All patients underwent radiography, standard MRI of the shoulder and SWMR. Radiograph-based identification of sub-coracoacromial spurs served as goldstandard. Radiographs identified twenty-three spurs in twenty-three patients. Twenty-one patients without spur formation served as reference group. Detection rate, sensitivity/specificity and interobserver-agreements were calculated. Linear regression was applied to determine the relationship between size measurements on radiographs and MRI. Detection rates for spurs on standard MRI and SWMR were 47.8 % and 91.3 % compared to radiography (p<0.001). SWMR demonstrated a sensitivity of 97.7 % (CI=0.92-1) and a specificity of 91.3 % (CI=0.788-1) for the identification of spurs. Standard MR-sequences achieved a sensitivity of 47.8 % (CI=0.185-0.775) and a specificity of 80.8 % (CI=0.642-0.978). Size measurements between SWMR and radiography showed a good correlation (R 2 =0.75;p<0.0001), while overestimating lesion size (5.7±1.2 mm; 4.3±1.3 mm;p<0.0001). Interobserver-agreement for spurs was high on SWMR (R 2 =0.74;p<0.0001), but low on standard MRI (R 2 =0.24;p<0.0001). SWMR allows a reliable detection of sub-coracoacromial spur formation in patients with SAIS and is superior to standard MR-sequences using radiography as goldstandard. (orig.)

  11. Magnetic resonance imaging in the cranio-cervical region

    International Nuclear Information System (INIS)

    Koschorek, F.; Jensen, H.P.; Terwey, B.

    1987-01-01

    Since the introduction of nuclear magnetic resonance imaging (NMR) in the neurosurgical and neurological diagnostic this new imaging modality has shown to be of high diagnostic value - especially in disease process of the cranio-vertebral junction. Other imaging moralities such as x-ray CT and myelography are of inferior quality as the images are degraded by bone artifacts and superposition of other structures. NMR can reveal many aspects of the cranio-vertebral region in a single examination without artifacts from surrounding structures. A further improvement of NMR is the introduction of para-magnetic agents, such as gadolinium-DTPA, as it increases the specifity by dynamic magnetic resonance imaging. The authors present a review of their clinical experience

  12. Force detection of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Rugar, D.; Zueger, O.; Hoen, S.; Yannoni, C.S.; Vieth, H.M.; Kendrick, R.D.

    1994-01-01

    Micromechanical sensing of magnetic force was used to detect nuclear magnetic resonance with exceptional sensitivity and spatial resolution. With a 900 angstrom thick silicon nitride cantilever capable of detecting subfemtonewton forces, a single shot sensitivity of 1.6 x 10 13 protons was achieved for an ammonium nitrate sample mounted on the cantilever. A nearby millimeter-size iron particle produced a 600 tesla per meter magnetic field gradient, resulting in a spatial resolution of 2.6 micrometers in one dimension. These results suggest that magnetic force sensing is a viable approach for enhancing the sensitivity and spatial resolution of nuclear magnetic resonance microimaging

  13. Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Chopra, A. [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Grainger, A.J.; Robinson, Philip [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Dube, B.; Evans, R.; Hodgson, R. [Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Conroy, J. [Harrogate and District NHS Trust, Trauma and Orthopaedics Department, Harrogate (United Kingdom); Macdonald, D. [Chapel Allerton Hospital, Trauma and Orthopaedics Department, Leeds Teaching Hospitals, Leeds (United Kingdom)

    2018-03-15

    To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI. circle Conventional 3T MRI is equivalent to 1.5T MRA for diagnosing labral tears. (orig.)

  14. Magnetic resonance elastometry using a single-sided permanent magnet

    International Nuclear Information System (INIS)

    Tan, Carl S; Marble, Andrew E; Ono, Yuu

    2012-01-01

    In this paper, we describe a magnetic resonance method of measuring material elasticity using a single-sided magnet with a permanent static field gradient. This method encodes sample velocity in a reciprocal space using Hahn spin-echoes with variable timing. The experimental results show a strong correlation between magnetic resonance signal attenuation and elasticity when an oscillating force is applied on the sample. This relationship in turn provides us with information about the displacement velocity experienced by the sample, which is inversely proportional to Young's modulus. The proposed method shows promise in offering a portable and cost-effective magnetic resonance elastography system. (paper)

  15. Artifacts in Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Krupa, Katarzyna; Bekiesińska-Figatowska, Monika

    2015-01-01

    Artifacts in magnetic resonance imaging and foreign bodies within the patient’s body may be confused with a pathology or may reduce the quality of examinations. Radiologists are frequently not informed about the medical history of patients and face postoperative/other images they are not familiar with. A gallery of such images was presented in this manuscript. A truncation artifact in the spinal cord could be misinterpreted as a syrinx. Motion artifacts caused by breathing, cardiac movement, CSF pulsation/blood flow create a ghost artifact which can be reduced by patient immobilization, or cardiac/respiratory gating. Aliasing artifacts can be eliminated by increasing the field of view. An artificially hyperintense signal on FLAIR images can result from magnetic susceptibility artifacts, CSF/vascular pulsation, motion, but can also be found in patients undergoing MRI examinations while receiving supplemental oxygen. Metallic and other foreign bodies which may be found on and in patients’ bodies are the main group of artifacts and these are the focus of this study: e.g. make-up, tattoos, hairbands, clothes, endovascular embolization, prostheses, surgical clips, intraorbital and other medical implants, etc. Knowledge of different types of artifacts and their origin, and of possible foreign bodies is necessary to eliminate them or to reduce their negative influence on MR images by adjusting acquisition parameters. It is also necessary to take them into consideration when interpreting the images. Some proposals of reducing artifacts have been mentioned. Describing in detail the procedures to avoid or limit the artifacts would go beyond the scope of this paper but technical ways to reduce them can be found in the cited literature

  16. Magnetic resonance imaging of generalised musculo-skeletal diseases

    International Nuclear Information System (INIS)

    Kaiser, W.A.; Schalke, B.C.G.

    1989-01-01

    The results presented are drawn from 320 examinations by NMR imaging of patients with various systemic muscle diseases (dystrophies, myositides, metabolic disorders), and are interpreted so as to explain the relevant characteristic distribution patterns of the degenerative processes in the femoral musculature as shown by the NMR images. Four basic patterns are presented according to the criteria homogeneous-heterogeneous and symmetric-asymmetric, and the diseases identified by the differential diagnostic evaluation are discussed. The optimum measuring conditions for magnetic resonance imaging of the musculature are given, and the specific magnetic resonance criteria of myositides, neurogenic myopathies, myofonous dystrophies, c.n. polio, morbus Pompe, familial hypokalemic paralysis, centronuclear mypathy, morbus Duchenne are explained. The significance of NMR imaging with regard to biopsy or therapy planning is discussed, and magnetic resonance examination is recommended to be applied prior to biopsy. (orig.) [de

  17. Magnetic resonance neurography for the identification of pudendal neuralgia

    Directory of Open Access Journals (Sweden)

    Claudia P. Cejas

    2017-06-01

    Full Text Available The pudendal nerve entrapment is an entity understudied by diagnosis imaging. Various causes are recognized in relation to difficult labors, rectal, perineal, urological and gynecological surgery, pelvic trauma fracture, bones tumors and compression by tumors or pelvic pseudotumors. Pudendal neuropathy should be clinically suspected, and confirmed by different methods such as electrofisiological testing: evoked potentials, terminal motor latency test and electromyogram, neuronal block and magnetic resonance imaging. The radiologist should be acquainted with the complex anatomy of the pelvic floor, particularly on the path of pudendal nerve studied by magnetic resonance imaging. High resolution magnetic resonance neurography should be used as a complementary diagnostic study along with clinical and electrophysiological examinations in patients with suspected pudendal nerve neuralgia.

  18. The introduction of clinical magnetic resonance imaging in Australia

    International Nuclear Information System (INIS)

    Sorby, W.; Baddeley, H.

    1986-01-01

    Magnetic resonance imaging is a new, but expensive, modality that is being introduced into clinical use in Australia. While it promises increased safety and accuracy in many situations, its precise role when compared with computed tomography and other modalities is not fully established. Therefore, a Government financed evaluation of costs and efficacy of magnetic resonance imaging units in five teaching hospitals is to be conducted over two years (1986-1988). Experience with the introduction of computed tomography to Australia and other nations has revealed difficulties in the evaluation by conventional methods of a diagnostic technology that is improving rapidly; it is to be hoped that a systematic evaluation of the clinical applications of magnetic resonance imaging will be more achievable and useful

  19. Magnetic resonance of seminal vesicles: a noninvasive study of seminal way

    International Nuclear Information System (INIS)

    Ocantos, J.A.; Rey Valzacchi, G.; Sinclair, M.E.; Loor Guadamud, G.

    2010-01-01

    The magnetic resonance without endorectal coil is an excellent diagnostic tool for studying the entire route of seminal non-invasive way in a single step diagnosis. We call magnetic resonance of seminal vesicles, but includes both the study of the seminal vesicles as the channels of the seminal way. [es

  20. ABC of the cardiac magnetic resonance. Part 1: perfusion, viability and coronary anatomy

    International Nuclear Information System (INIS)

    Loureiro, Ricardo; Rached, Heron; Castro, Claudio C.; Cerri, Giovanni G.; Favaro, Daniele; Baptista, Luciana; Andrade, Joalbo; Rochitte, Carlos E.; Parga Filho, Jose; Avila, Luiz F.; Piva, Rosa M.V.

    2003-01-01

    The objective of this work is to demonstrate the fundamental concepts, the basic sequences and the clinical and potential applications of cardiac magnetic resonance as a diagnostic technique in updated radiology and cardiology practices. In this second part, we present basic aspects of the cardiac magnetic resonance application in the coronary anatomy and myocardial perfusion and viability. (author)

  1. Cardiovascular magnetic resonance in pericardial diseases

    Directory of Open Access Journals (Sweden)

    Francone Marco

    2009-05-01

    Full Text Available Abstract The pericardium and pericardial diseases in particular have received, in contrast to other topics in the field of cardiology, relatively limited interest. Today, despite improved knowledge of pathophysiology of pericardial diseases and the availability of a wide spectrum of diagnostic tools, the diagnostic challenge remains. Not only the clinical presentation may be atypical, mimicking other cardiac, pulmonary or pleural diseases; in developed countries a shift for instance in the epidemiology of constrictive pericarditis has been noted. Accurate decision making is crucial taking into account the significant morbidity and mortality caused by complicated pericardial diseases, and the potential benefit of therapeutic interventions. Imaging herein has an important role, and cardiovascular magnetic resonance (CMR is definitely one of the most versatile modalities to study the pericardium. It fuses excellent anatomic detail and tissue characterization with accurate evaluation of cardiac function and assessment of the haemodynamic consequences of pericardial constraint on cardiac filling. This review focuses on the current state of knowledge how CMR can be used to study the most common pericardial diseases.

  2. Magnetic resonance tomography of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Puig, Stefan; Kuruvilla, Yojena Chittazhathu Kurian; Ebner, Lukas [University Hospital, University of Berne, Department of Interventional, Pediatric and Diagnostic Radiology Inselspital, Berne (Switzerland); Endel, Gottfried [Main Association of Austrian Social Insurance Institutions, Vienna (Austria)

    2015-10-15

    To compare the diagnostic performance of magnetic resonance imaging (MRI) in terms of sensitivity and specificity using a field strength of <1.0 T (T) versus ≥1.5 T for diagnosing or ruling out knee injuries or knee pathologies. The systematic literature research revealed more than 10,000 references, of which 1598 abstracts were reviewed and 87 full-text articles were retrieved. The further selection process resulted in the inclusion of four systematic reviews and six primary studies. No differences could be identified in the diagnostic performance of low- versus high-field MRI for the detection or exclusion of meniscal or cruciate ligament tears. Regarding the detection or grading of cartilage defects and osteoarthritis of the knee, the existing evidence suggests that high-field MRI is tolerably specific but not very sensitive, while there is literally no evidence for low-field MRI because only a few studies with small sample sizes and equivocal findings have been performed. We can recommend the use of low-field strength MRI systems in suspected meniscal or cruciate ligament injuries. This does, however, not apply to the diagnosis and grading of knee cartilage defects and osteoarthritis because of insufficient evidence. (orig.)

  3. Magnetic resonance tomography of the knee joint

    International Nuclear Information System (INIS)

    Puig, Stefan; Kuruvilla, Yojena Chittazhathu Kurian; Ebner, Lukas; Endel, Gottfried

    2015-01-01

    To compare the diagnostic performance of magnetic resonance imaging (MRI) in terms of sensitivity and specificity using a field strength of <1.0 T (T) versus ≥1.5 T for diagnosing or ruling out knee injuries or knee pathologies. The systematic literature research revealed more than 10,000 references, of which 1598 abstracts were reviewed and 87 full-text articles were retrieved. The further selection process resulted in the inclusion of four systematic reviews and six primary studies. No differences could be identified in the diagnostic performance of low- versus high-field MRI for the detection or exclusion of meniscal or cruciate ligament tears. Regarding the detection or grading of cartilage defects and osteoarthritis of the knee, the existing evidence suggests that high-field MRI is tolerably specific but not very sensitive, while there is literally no evidence for low-field MRI because only a few studies with small sample sizes and equivocal findings have been performed. We can recommend the use of low-field strength MRI systems in suspected meniscal or cruciate ligament injuries. This does, however, not apply to the diagnosis and grading of knee cartilage defects and osteoarthritis because of insufficient evidence. (orig.)

  4. Magnetic Resonance Imaging (MRI) with retrograde intralumen contrast enhancement of the rectum in diagnostics of rectovaginal fistulas after combination therapy of rectal cancer. Experience of application

    Science.gov (United States)

    Usova, A.; Frolova, I.; Afanasev, S.; Tarasova, A.; Molchanov, S.

    2016-02-01

    Experiment of use of MRI in diagnostics of rectovaginal fistulas after combination therapy of rectal cancer is shown on clinical examples. We used retrograde contrasting of a rectum with 150ml ultrasonic gel to make MRI more informative in case of low diagnostic efficiency of ultrasound, colonoscopy and gynecological examination.

  5. Magnetic resonance in obstructive jaundice

    International Nuclear Information System (INIS)

    Gupta, R.K.; Jena, A.; Khushu, S.; Kakar, A.K.; Mishra, P.K.

    1989-01-01

    Twelve cases of obstructive jaundice in whom ultrasound failed to demonstrate the site and/or the cause of obstruction of the biliary tract were examined with magnetic resonance imaging (MRI), correctly diagnosing the site and cause of obstruction in 10 of 12 surgically proven cases. In one case of cholangiocarcinoma, the site of obstruction was well shown on MR but a definite cause could not be ascertained. In another patient who developed intermittent jaundice following surgery for choledochal cyst, MR demonstrated a solitary stone in the common hepatic duct. Surgical confirmation could not be achieved as the patient was lost to follow up. There were 6 cases of choledocholithiasis, 3 cases of gall bladder carcinoma and one case each of pancreatic adenocarcinoma and cholangiocarcinoma. It is believed that MRI will provide obstructive jaundice and will be able to minimize the use of percutaneous transhepatic cholangiography (PTC) and endoscopic retrograde cholangiopancreatography (ERCP) in view of its ability to perform multiplanar imaging in multiple sequences. 11 refs., figs., 1 tab

  6. Low rank magnetic resonance fingerprinting.

    Science.gov (United States)

    Mazor, Gal; Weizman, Lior; Tal, Assaf; Eldar, Yonina C

    2016-08-01

    Magnetic Resonance Fingerprinting (MRF) is a relatively new approach that provides quantitative MRI using randomized acquisition. Extraction of physical quantitative tissue values is preformed off-line, based on acquisition with varying parameters and a dictionary generated according to the Bloch equations. MRF uses hundreds of radio frequency (RF) excitation pulses for acquisition, and therefore high under-sampling ratio in the sampling domain (k-space) is required. This under-sampling causes spatial artifacts that hamper the ability to accurately estimate the quantitative tissue values. In this work, we introduce a new approach for quantitative MRI using MRF, called Low Rank MRF. We exploit the low rank property of the temporal domain, on top of the well-known sparsity of the MRF signal in the generated dictionary domain. We present an iterative scheme that consists of a gradient step followed by a low rank projection using the singular value decomposition. Experiments on real MRI data demonstrate superior results compared to conventional implementation of compressed sensing for MRF at 15% sampling ratio.

  7. Endometrial cancer: magnetic resonance imaging.

    Science.gov (United States)

    Manfredi, R; Gui, B; Maresca, G; Fanfani, F; Bonomo, L

    2005-01-01

    Carcinoma of the endometrium is the most common invasive gynecologic malignancy of the female genital tract. Clinically, patients with endometrial carcinoma present with abnormal uterine bleeding. The role of magnetic resonance imaging (MRI) in endometrial carcinoma is disease staging and treatment planning. MRI has been shown to be the most valuable imaging mod-ality in this task, compared with endovaginal ultrasound and computed tomography, because of its intrinsic contrast resolution and multiplanar capability. MRI protocol includes axial T1-weighted images; axial, sagittal, and coronal T2-weighted images; and dynamic gadolinium-enhanced T1-weighted imaging. MR examination is usually performed in the supine position with a phased array multicoil using a four-coil configuration. Endometrial carcinoma is isointense with the normal endometrium and myometrium on noncontrast T1-weighted images and has a variable appearance on T2-weighted images demonstrating heterogeneous signal intensity. The appearance of noninvasive endometrial carcinoma on MRI is characterized by a normal or thickened endometrium, with an intact junctional zone and a sharp tumor-myometrium interface. Invasive endometrial carcinoma is characterized disruption or irregularity of the junctional zone by intermediate signal intensity mass on T2-weighted images. Invasion of the cervical stroma is diagnosed when the low signal intensity cervical stroma is disrupted by the higher signal intensity endometrial carcinoma. MRI in endometrial carcinoma performs better than other imaging modalities in disease staging and treatment planning. Further, the accuracy and the cost of MRI are equivalent to those of surgical staging.

  8. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  9. Magnetic resonance imaging and neurolupus

    International Nuclear Information System (INIS)

    Schott, A.M.; Colson, F.; Tebib, J.; Noel, E.; Bouvier, M.

    1990-01-01

    Magnetic resonance imaging (MRI) was assessed in the management of neuropsychiatric manifestations occurring in 6 SLE patients. The MRI scans were normal in 3 cases and was associated with remission of the symptoms except for a patient who experienced a chorea at the time of the examination. Abnormal MRI scans always revealed more lesions than CT scan. 2 different patterns of abnormalities seem to correspond to 2 specific disorders. In 2 patients with clinical presentation suggesting a cortical ischemia by vascular thrombosis, both MRI scans showed areas of abnormal high signal intensities located in the subcortical white matter. In one last patient, MRI scan revealed multiple focal areas of high signal intensities (on T 1 weighter scans) disseminated not only in the deep white matter but also in the gray one. These lesions could be depend upon demyelinisation which may occur by a local vascular process. This serie confirms the interest of MRI in the management of SLE brain involvement as well as it points out some problem of interpretation. This suggest further comparative studies especially at the real onset and during the course of neuro-psychiatric manifestations. At last, the coronal sections may be more informative for the diagnosis and patholophysiology than the horizontal ones [fr

  10. Myositis ossificans: magnetic resonance images

    International Nuclear Information System (INIS)

    Dosda, R.; Marti-Bonmati, L.; Concepcion, L.; Galant, J.

    1999-01-01

    Myositis ossificans is characterized by a benign, self-limiting, ossifying mass of the white tissue. In the present report, we describe the magnetic resonance (MR) images in three cases of myositis ossificans in pediatric patients, correlating the MR findings with those obtained with other radiological studies. The lesions were detected in three patients, two boys and one girl, ranging in age between 10 and 14 years. The nature of the lesion was confirmed histologically in all three cases. The MR images were obtained using superconductive units at 0.5 Teslas, with T1 and T2-weighted spin-echo and STIR sequences. In two patients, gadolinium-enhanced T1-weighted images were also obtained. As in any process of maturation, the proliferation/maturation ratio depends on the moment in the course of the lesion, which affects its MR features,. In acute phases, the soft tissue mass with an intraosseous, perilesional adematous reaction predominates, while annular calcification and lesser edema are characteristic of subacute episode. Myositis ossificans is very rare in children. The inflammatory response may present a radiological pattern difficult to distinguish from that of aggressive tumor or infection, especially in the acute phase. (Author) 7 refs

  11. Cardiovascular magnetic resonance in congenital heart disease

    International Nuclear Information System (INIS)

    Cazacu, A.; Ciubotaru, A.

    2010-01-01

    The increasing prevalence of congenital heart disease can be attributed to major improvements in diagnosis and treatment. Cardiovascular magnetic resonance imaging plays an important role in the clinical management strategy of patients with congenital heart disease. The development of new cardiovascular magnetic resonance (CMR) techniques allows comprehensive assessment of complex cardiac anatomy and function and provides information about the long-term residual post-operative lesions and complications of surgery. It overcomes many of the limitations of echocardiography and cardiac catheterization. This review evaluates the role of cardiovascular magnetic resonance imaging modality in the management of subject with congenital heart disease (CHD). (authors)

  12. Functional magnetic resonance imaging by visual stimulation

    International Nuclear Information System (INIS)

    Nishimura, Yukiko; Negoro, Kiyoshi; Morimatsu, Mitsunori; Hashida, Masahiro

    1996-01-01

    We evaluated functional magnetic resonance images obtained in 8 healthy subjects in response to visual stimulation using a conventional clinical magnetic resonance imaging system with multi-slice spin-echo echo planar imaging. Activation in the visual cortex was clearly demonstrated by the multi-slice experiment with a task-related change in signal intensity. In addition to the primary visual cortex, other areas were also activated by a complicated visual task. Multi-slice spin-echo echo planar imaging offers high temporal resolution and allows the three-dimensional analysis of brain function. Functional magnetic resonance imaging provides a useful noninvasive method of mapping brain function. (author)

  13. NMR magnetic field controller for pulsed nuclear magnetic resonance experiments

    International Nuclear Information System (INIS)

    Scheler, G.; Anacker, M.

    1975-01-01

    A nuclear magnetic resonance controller for magnetic fields, which can also be used for pulsed NMR investigations, is described. A longtime stability of 10 -7 is achieved. The control signal is generated by a modified time sharing circuit with resonance at the first side band of the 2 H signal. An exact calibration of the magnetic field is achieved by the variation of the H 1 - or of the time-sharing frequency. (author)

  14. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  15. [Diagnostic efficiency of decline rate of signal intensity and apparent diffusion coefficient with different b values for differentiating benign and malignant breast lesions on diffusion-weighted 3.0T magnetic resonance imaging].

    Science.gov (United States)

    Jiang, Jing; Liu, Wanhua; Ye, Yuanyuan; Wang, Rui; Li, Fengfang; Peng, Chengyu

    2014-06-17

    To investigate the diagnostic efficiency of decline rate of signal intensity and apparent diffusion coefficient with different b values for differentiating benign and malignant breast lesions on diffusion-weighted 3.0 T magnetic resonance imaging. A total of 152 patients with 162 confirmed histopathologically breast lesions (85 malignant and 77 benign) underwent 3.0 T diffusion-weighted magnetic resonance imaging. Four b values (0, 400, 800 and 1 000 s/mm²) were used. The signal intensity and ADC values of breast lesions were measured respectively. The signal intensity decline rate (SIDR) and apparent diffusion coefficient decline rate (ADCDR) were calculated respectively. SIDR = (signal intensity of lesions with low b value-signal intensity of lesions with high b value)/signal intensity of lesions with low b value, ADCDR = (ADC value of lesions with low b value-ADC value of lesions with high b value) /ADC value of lesions with low b value. The independent sample t-test was employed for statistical analyses and the receiver operating characteristic (ROC) curve for evaluating the diagnosis efficiency of SIDR and ADCDR values. Significant differences were observed in SIDR between benign and malignant breast lesions with b values of 0-400, 400-800 and 800-1 000 s/mm². The sensitivities of SIDR for differentiating benign and malignant breast lesions were 61.2%, 68.2% and 67.1%, the specificities 74.0%, 85.7% and 67.5%, the diagnosis accordance rates 67.3%, 76.5% and 67.3%, the positive predictive values 72.2%, 84.1% and 69.5% and the negative predictive values 63.3%, 71.0% and 65.0% respectively. Significant differences were observed in ADCDR between benign and malignant breast lesions with b values of 400-800 s/mm² and 800-1 000 s/mm². The sensitivities of SDR for differentiating benign and malignant breast lesions were 80.0% and 65.9%, the specificities 72.7% and 65.0%, the diagnostic accordance rates 76.5% and 65.4%, the positive predictive values 76.4% and 67

  16. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  17. 1H magnetic resonance spectroscopy of the brain in paediatrics: The diagnosis of creatine deficiencies

    NARCIS (Netherlands)

    Sijens, P.E.; Oudkerk, M.

    2005-01-01

    The diagnosis of creatine deficiencies, a paediatric application of magnetic resonance spectroscopy that has already become a diagnostic tool in clinical practice, is reviewed and illustrated with results from recent examinations

  18. Pocket atlas of cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Haughton, V.M.; Daniels, D.L.

    1986-01-01

    This atlas illustrates normal cerebral anatomy in magnetic resonance images. From their studies in cerebral anatomy utilizing cryomicrotome and other techniques, the authors selected more than 100 high-resolution images that represent the most clinically useful scans

  19. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  20. Fifty years of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Martinez Valderrama, Juan Crisostomo

    1997-01-01

    Short information about the main developments of nuclear magnetic resonance during their fifty existence years is presented. Beside two examples of application (HETCOR and INADEQUATE) to the structural determination of organic compounds are described

  1. Principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Pykett, I.L.; Newhouse, J.H.; Buonanno, F.S.; Brady, T.J.; Goldman, M.R.; Kistler, J.P.; Pohost, G.M.

    1982-01-01

    The physical principles which underlie the phenomenon of nuclear magnetic resonance (NMR) are presented in this primer. The major scanning methods are reviewed, and the principles of technique are discussed. A glossary of NMR terms is included

  2. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  3. The role of magnetic resonance cholangiopancreatography and ...

    African Journals Online (AJOL)

    ) is accepted as the gold standard, there is a place for magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted imaging (DWI) in the diagnosis of obstructive biliary disorders. Aim: To compare the findings of MRCP with ...

  4. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  5. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  6. Chronic liver disease: evaluation by magnetic resonance

    International Nuclear Information System (INIS)

    Stark, D.D.; Goldberg, H.I.; Moss, A.A.; Bass, N.M.

    1984-01-01

    Magnetic resonance (MR) imaging distinguished hepatitis from fatty liver and cirrhosis in a woman with a history of alcohol abuse. Anatomic and physiologic manifestations of portal hypertension were also demonstrated by MR

  7. Nuclear Magnetic Resonance Trackbed Moisture Sensor System

    Science.gov (United States)

    2018-02-01

    In this initial phase, conducted from March 2015 through December 2016, Vista Clara and its subcontractor Zetica Rail successfully developed and tested a man-portable, non-invasive spot-check nuclear magnetic resonance (NMR) moisture sensor that dire...

  8. Magnetic diagnostics for the proto-eta Tokamak

    International Nuclear Information System (INIS)

    Ferreira, J.L.; Aso, Y.; Ueda, M.; Ferreira, J.G.

    1991-04-01

    This work gives a general view of the magnetic diagnostics rat will be used in the Proto-Eta Tokamak. These diagnostics will be useful tools to measure currents, electric and magnetic fields involved in the plasma magnetic confinement. (author)

  9. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  10. Nuclear magnetic resonance spectroscopy and imaging

    International Nuclear Information System (INIS)

    Jiang Weiping; Wang Qi; Zhou Xin

    2013-01-01

    This paper briefly introduces the basic principle of nuclear magnetic resonance (NMR). Protein's structures and functions and dynamics studied by liquid NMR are elaborated; methods for enhancing the resolution of solid state NMR and its applications are discussed; the principle of magnetic resonance imaging (MRI) is interpreted, and applications in different aspects are reviewed. Finally, the progress of NMR is commented. (authors)

  11. Concepts and indications of abdominal magnetic resonance

    International Nuclear Information System (INIS)

    Murillo Viera, Wendy

    2012-01-01

    A literature review and conceptualization was performed of the main indications of magnetic resonance studies of the abdomen and the characteristic findings for each sequence, according to organ and pathology. The radiologist has had in mind main indications for magnetic resonance studies of the abdomen, with the purpose to guide the clinician in the choice of imaging modality that works best for the patient at diagnosis [es

  12. Magnetic resonance imaging of muscle tears

    International Nuclear Information System (INIS)

    De Smet, A.A.; Fisher, D.R.; Heiner, J.P.; Keene, J.S.

    1990-01-01

    Magnetic resonance scans were obtained on 17 patients with acute, subacute, or chronic muscle tears. These patients presented with complaints of persistent pain or a palpable mass. Magnetic resonance findings were characterized according to alterations in muscle shape and the presence of abnormal high signal within the injured muscle. These areas of high signal were noted on both T1-weighted and T2-weighted scans and were presumed to represent areas of intramuscular hemorrhage. (orig.)

  13. Clinical magnetic resonance: imaging and spectroscopy

    International Nuclear Information System (INIS)

    Andrew, E.R.; Bydder, Graeme; Griffiths, John; Iles, Richard; Styles, Peter

    1990-01-01

    This book begins with a readable, comprehensive but non-mathematical introduction to the basic underlying principles of magnetic resonance. Further chapters include information on the theory and principles of MRI and MRS, the interpretation of MR images, the clinical applications and scope of MRI and MRS, practical aspects of spectroscopy and magnetic resonance, and also the practical problems associated with the siting, safety and operation of large MRI and MRS equipment. (author)

  14. Nuclear magnetic resonance method and apparatus

    International Nuclear Information System (INIS)

    Burl, M.; Young, I.R.

    1984-01-01

    A method and apparatus for determining the rate of flow of a liquid in a selected region of a body by nuclear magnetic resonance techniques are described. The method includes a sequence of applying a first magnetic pulse effective to excite nuclear magnetic resonance of a chosen nucleus within the liquid preferentially in a slice of the body which includes the selected region. A period of time (tsub(D)) is waited and then a second magnetic pulse is applied which is effective to excite nuclear magnetic resonance of the nuclei preferentially in the slice, and the free induction decay signal is measured. The whole sequence is repeated for different values of the period of time (tsub(D)). The variation in the value of the measured signal with tsub(D) is then related to the rate of flow of the liquid through the slice. (author)

  15. The origins and future of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wehrli, F.W.

    1992-01-01

    What began as a curiosity of physics has become the preeminent method of diagnostic medical imaging and may displace x-ray-based techniques in the 21st century. During the past two decades nuclear magnetic resonance has revolutionized chemistry, biochemistry, biology and, more recently, diagnostic medicine. Nuclear magnetic resonance imaging, (MRI) as it is commonly called, is fundamentally different from x-ray-based techniques in terms of the principles of spatial encoding and mechanisms of signal and contrast generation involved. MRI has a far richer ultimate potential than any other imaging technique known today, and its technology and applications are still far from maturation, which may not occur until early in the 21st century. 23 refs., 6 figs

  16. Magnetic resonance imaging in neurologic diseases

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Han, Man Chung; Wan, Chu Wan; Myung, Ho Jin; Choi, Kil Soo; Ahn, Chang Beom; Oh, Chang Hyun; Cho, Zang Hee

    1985-01-01

    Magnetic resonance (MR) imaging with 0.15 Tesla resistive magnet developed by Korea Advanced Institute of Science were performed in 27 patients with various neurologic diseases and compared with x-ray computed tomography (CT). The purpose of the paper is to evaluate the image quality, the diagnostic value and limitation, and the optimal pulse sequence of MR imagings with a resistive magnet. The MR images were obtained by using a variety of pulse sequence with spin echo technique including saturation recovery. T2-weighted spin echo, and/or inversion recovery with various pulse repetition (TR) and echo delay (TE) times. The MR imaging demonstrated the capability of detecting the lesions shown on CT in al cases and also detected an additional finding in one case (multiple sclerosis) which was not seen on CT. The MR imaging appeared to be more useful than CT in the evaluation of syringomyelia of spinal cord and white matter disease, while it failed to demonstrated small calcific lesion or inflammatory nodule (less than 1 cm) shown on CT and has shown somewhat poor contrast resolution in the case of meingloma. The spatial resolution of saturation recovery images was similar or superior to CT, whereas the contrast resolution of saturation recovery was inferior to CT. While the saturation recovery images have shown false negative findings in 5 patients (19%), the inversion recovery and T2-weighted spin echo have shown consistently positive findings. The inversive recovery and T2-weighted spin echo images demonstrated better contrast discrimination between normal and pathologic conditions than the saturation recovery images, but somewhat poorer spatial resolution. Authors suggest that the MR images of both the saturation recovery with 300/30 and T2-weighted spin echo with 1000/90 be used as a routine procedure and additional inversion recovery of 1300/300/30 sequence as a option if white matter disease is suspected

  17. Functional Magnetic Resonance in the Evaluation of Oesophageal Motility Disorders

    OpenAIRE

    Covotta, Francesco; Piretta, Luca; Badiali, Danilo; Laghi, Andrea; Biondi, Tommaso; Corazziari, Enrico S.; Panebianco, Valeria

    2011-01-01

    Functional magnetic resonance imaging (fMRI) has been recently proposed for the evaluation of the esophagus. Our aim is to assess the role of fMRI as a technique to assess morphological and functional parameters of the esophagus in patients with esophageal motor disorders and in healthy controls. Subsequently, we assessed the diagnostic efficiency of fMRI in comparison to videofluoroscopic and manometric findings in the investigation of patients with esophageal motor disorders. Considering...

  18. Indications and technique of fetal magnetic resonance imaging

    International Nuclear Information System (INIS)

    Asenbaum, U.; Woitek, R.; Furtner, J.; Prayer, D.; Brugger, P.C.

    2013-01-01

    Evaluation and confirmation of fetal pathologies previously suspected or diagnosed with ultrasound. Ultrasound and magnetic resonance imaging (MRI). Technique for prenatal fetal examination. Fetal MRI is an established supplementary technique to prenatal ultrasound. Fetal MRI should only be used as an additional method in prenatal diagnostics and not for routine screening. Fetal MRI should only be performed in perinatal medicine centers after a previous level III ultrasound examination. (orig.) [de

  19. Resonance double magnetic bremsstrahlung in a strong magnetic field

    International Nuclear Information System (INIS)

    Fomin, P.I.; Kholodov, R.I.

    2003-01-01

    The possibility of resonance double magnetic bremsstrahlung in the approximation of weakly excited electron states in a strong external magnetic field is analyzed. The differential probability of this process in the Breit-Wigner form is obtained. The probability of double magnetic bremsstrahlung (second-order process of perturbation theory) is compared with the probability of magnetic bremsstrahlung (first-order process of perturbation theory)

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. Your child will lie on a moveable examination ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  6. A Novel Diagnostic Aid for Detection of Intra-Abdominal Adhesions to the Anterior Abdominal Wall Using Dynamic Magnetic Resonance Imaging

    NARCIS (Netherlands)

    Randall, D.; Fenner, J.; Gillott, R.; Broek, R.P.G ten; Strik, C.; Spencer, P.; Bardhan, K.D.

    2016-01-01

    Introduction. Abdominal adhesions can cause serious morbidity and complicate subsequent operations. Their diagnosis is often one of exclusion due to a lack of a reliable, non-invasive diagnostic technique. Development and testing of a candidate technique are described below. Method. During

  7. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis

    NARCIS (Netherlands)

    van der Hoorn, Anouk; van Laar, Peter Jan; Holtman, Gea A.; Westerlaan, Henriette E.

    2017-01-01

    Background Novel advanced MRI techniques are investigated in patients treated for head and neck tumors as conventional anatomical MRI is unreliable to differentiate tumor from treatment related imaging changes. Purpose As the diagnostic accuracy of MRI techniques to detect tumor residual or

  8. Magnetic islands created by resonant helical windings

    International Nuclear Information System (INIS)

    Fernandes, A.S.; Heller, M.V.; Caldas, I.L.

    1986-01-01

    The triggering of disruptive instabilities by resonant helical windings in large aspect-ratio tokamaks is associated to destruction of magnetic surfaces. The Chirikov condition is applied to estimate analytically the helical winding current thresholds for ergodization of the magnetic field lines. (Autor) [pt

  9. Topical questions in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Andrew, E.R.; Florida Univ., Gainesville, FL; Florida Univ., Gainesville, FL

    1989-01-01

    This paper examines a number of practical questions concerning magnetic resonance imaging. These include the choice of operating magnetic field strength, the problem of siting and screening, a procedure for securing precise slice selection and the use of paramagnetic contrast agents. (author). 5 refs

  10. Particle diagnostics for magnetic fusion experiments

    International Nuclear Information System (INIS)

    Post, D.E.

    1983-01-01

    This chapter summarizes the subset of diagnostics that relies primarily on the use of particles, and attempts to show how atomic and molecular data play a role in these diagnostics. Discusses passive charge-exchange ion temperature measurements; hydrogen beams for density, ion temperature, q and ZEFF measurements; impurity diagnostics using charge-exchange recombination; plasma electric and magnetic measurements using beams heavier than hydrogen; and alpha particle diagnostics. Points out that as fusion experiments become larger and hotter, most traditional particle diagnostics become difficult because large plasmas are difficult for neutral atoms to penetrate and the gyro-orbits of charged particles need to be larger than typically obtained with present beams to be comparable with the plasma size. Concludes that not only does the current profile affect the plasma stability, but there is a growing opinion that any serious fusion reactor will have to be steady state

  11. Brain Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy Findings of Children with Kernicterus

    International Nuclear Information System (INIS)

    Sarı, Sahabettin; Yavuz, Alpaslan; Batur, Aabdussamet; Bora, Aydın; Caksen, Huseyin

    2015-01-01

    The term kernicterus, or bilirubin encephalopathy, is used to describe pathological bilirubin staining of the basal ganglia, brain stem, and cerebellum, and is associated with hyperbilirubinemia. Kernicterus generally occurs in untreated hyperbilirubinemia or cases where treatment is delayed. Magnetic resonance imaging (MRI)-based studies have shown characteristic findings in kernicterus. The objective of our study was to describe the role of 1 H magnetic resonance spectroscopy (MRS) in demonstrating these metabolic changes and to review conventional MRI findings of kernicterus. Forty-eight pediatric cases with kernicterus were included in this study. MRI and MRS examinations were performed on variable dates (10–29 days after birth). NAA, Cr, Cho, NAA/Cr, NAA/Cho, and Cho/Cr values were evaluated visually and by computer analysis. There was no statistically significant difference between the NAA and Cho levels in the acute kernicterus patients and the control group (healthy patients), whereas both were significantly elevated in the chronic kernicterus patients. Both the mean NAA/Cr and Cho/Cr ratio values were significantly higher in the acute and chronic cases compared to the control group. The NAA/Cho ratio value was statistically lower in the acute cases than in the control group while it was similar in the chronic cases. Conventional MR imaging and 1 H-MRS are important complementary tools in the diagnostics of neonatal bilirubin encephalopathy. This study provided important information for applying these MR modalities in the evaluation of neonates with bilirubin encephalopathy

  12. Basis of the nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Bahceli, S.

    1996-08-01

    The aim of this book which is translated from English language is to explain the physical and mathematical basis of nuclear magnetic resonance (NMR). There are nine chapters covering different aspects of NMR. In the firs chapter fundamental concepts of quantum mechanics are given at a level suitable for readers to understand NMR fully. The remaining chapters discuss the magnetic properties of nucleus, the interactions between atoms and molecules, continuous wave NMR, pulsed NMR, nuclear magnetic relaxation and NMR of liquids

  13. Fetal magnetic resonance imaging of thoracic and abdominal malformations

    International Nuclear Information System (INIS)

    Woitek, R.; Asenbaum, U.; Furtner, J.; Prayer, D.; Brugger, P.C.

    2013-01-01

    Diagnosis and differential diagnosis of fetal thoracic and abdominal malformations. Ultrasound and magnetic resonance imaging (MRI). In cases of suspected pathologies based on fetal ultrasound MRI can be used for more detailed examinations and can be of assistance in the differential diagnostic process. Improved imaging of anatomical structures and of the composition of different tissues by the use of different MRI sequences. Fetal MRI has become a part of clinical routine in thoracic and abdominal malformations and is the basis for scientific research in this field. In cases of thoracic or abdominal malformations fetal MRI provides important information additional to ultrasound to improve diagnostic accuracy, prognostic evaluation and surgical planning. (orig.) [de

  14. Magnetic resonance tomography in comprehensive examination of epileptic children

    International Nuclear Information System (INIS)

    Akberov, R.F.; Mikhajlov, I.M.; Chernova, G.G.

    1995-01-01

    The paper presets the results of examining 100 children suffering from various epilepsies by magnetic resonance tomography, which determined a morphological substrate of the disease in 26%. The findings were compared with the clinical picture and the results of routine study tools (skull X-ray, EEC). The diagnostic value of the techniques applied was defined. Jt is concluded that a set of diagnostic tools rather than individual techniques should be applied to reveal etiological and pathogenetic factors of the disease. 5 refs., 6 figs

  15. Spontaneous intracranial hypotension syndrome: magnetic resonance findings in two patients

    International Nuclear Information System (INIS)

    Ortega, R.; Pastor, J.; Escamilla, F.; Romero, M. I.

    1999-01-01

    The postural headache syndrome associated with a decrease in the cerebrospinal fluid (CSF) pressure is generally secondary to the CSF leakage that usually occurs after diagnostic lumbar puncture. Spontaneous intracranial hypotension can not be attributed to any known cause or previous diagnostic or therapeutic intervention. The syndrome is characterized by severe headache that is relieved by lying supine. During lumbar puncture, the CSF pressure is normally low. We present two patients in whom gadolinium-enhanced magnetic resonance imaging showed widespread thickening and enhancement of the dura mater and subdural fluid collections. (Author) 13 refs

  16. Molecular diagnostics using magnetic nanobeads

    International Nuclear Information System (INIS)

    Zardan Gomez de la Torre, Teresa; Stroemberg, Mattias; Goeransson, Jenny; Stroemme, Maria; Gunnarsson, Klas; Svedlindh, Peter; Nilsson, Mats

    2010-01-01

    In this paper, we investigate the volume-amplified magnetic nanobead detection assay with respect to bead size, bead concentration and bead oligonucleotide surface coverage in order to improve the understanding of the underlying microscopic mechanisms. It has been shown that: (i) the immobilization efficiency of the beads depends on the surface coverage of oligonucleotides, (ii) by using lower amounts of probe-tagged beads, detection sensitivity can be improved and (iii) using small enough beads enables both turn-off and turn-on detection. Finally, biplex detection was demonstrated.

  17. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  18. Magnetic resonance imaging: effects of magnetic field strength

    International Nuclear Information System (INIS)

    Crooks, L.E.; Arakawa, M.; Hoenninger, J.; McCarten, B.; Watts, J.; Kaufman, L.

    1984-01-01

    Magnetic resonance images of the head, abdomen, and pelvis of normal adult men were obtained using varying magnetic field strength, and measurements of T1 and T2 relaxations and of signal-to-noise (SN) ratios were determined. For any one spin echo sequence, gray/white matter contrast decreases and muscle/fat contrast increases with field. SN levels rise rapidly up to 3.0 kgauss and then change more slowly, actually dropping for muscle. The optimum field for magnetic resonance imaging depends on tissue type, body part, and imaging sequence, so that it does not have a unique value. Magnetic resonance systems that operate in the 3.0-5.0 kgauss range achieve most or all of the gains that can be achieved by higher magnetic fields

  19. Accuracy of magnetic resonance in identifying traumatic intraarticular knee lesions

    International Nuclear Information System (INIS)

    Vaz, Carlos Eduardo Sanches; Camargo, Olavo Pires de; Santana, Paulo Jose de; Valezi, Antonio Carlos

    2005-01-01

    Purpose: To evaluate the diagnostic accuracy of magnetic resonance imaging of the knee in identifying traumatic intraarticular knee lesions. Method: 300 patients with a clinical diagnosis of traumatic intraarticular knee lesions underwent prearthoscopic magnetic resonance imaging. The sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratio for a positive test, likelihood ratio for a negative test, and accuracy of magnetic resonance imaging were calculated relative to the findings during arthroscopy in the studied structures of the knee (medial meniscus, lateral meniscus, anterior cruciate ligament, posterior cruciate ligament, and articular cartilage). Results: Magnetic resonance imaging produced the following results regarding detection of lesions: medial meniscus: sensitivity 97.5%, specificity 92.9%, positive predictive value 93.9%, positive negative value 97%, likelihood positive ratio 13.7, likelihood negative ratio 0.02, and accuracy 95.3%; lateral meniscus: sensitivity 91.9%, specificity 93.6%, positive predictive value 92.7%, positive negative value 92.9%, likelihood positive ratio 14.3, likelihood negative ratio 0.08, and accuracy 93.6%; anterior cruciate ligament: sensitivity 99.0%, specificity 95.9%, positive predictive value 91.9%, positive negative value 99.5%, likelihood positive ratio 21.5, likelihood negative ratio 0.01, and accuracy 96.6%; posterior cruciate ligament: sensitivity 100%, specificity 99%, positive predictive value 80.0%, positive negative value 100%, likelihood positive ratio 100, likelihood negative ratio 0.01, and accuracy 99.6%; articular cartilage: sensitivity 76.1%, specificity 94.9%, positive predictive value 94.7%, positive negative value 76.9%, likelihood positive ratio 14.9, likelihood negative ratio 0.25, and accuracy 84.6%. Conclusion: Magnetic resonance imaging is a satisfactory diagnostic tool for evaluating meniscal and ligamentous lesions of the knee, but it is unable to clearly

  20. Accuracy of magnetic resonance in identifying traumatic intraarticular knee lesions

    Directory of Open Access Journals (Sweden)

    Vaz Carlos Eduardo Sanches

    2005-01-01

    Full Text Available PURPOSE: To evaluate the diagnostic accuracy of magnetic resonance imaging of the knee in identifying traumatic intraarticular knee lesions. METHOD: 300 patients with a clinical diagnosis of traumatic intraarticular knee lesions underwent prearthoscopic magnetic resonance imaging. The sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratio for a positive test, likelihood ratio for a negative test, and accuracy of magnetic resonance imaging were calculated relative to the findings during arthroscopy in the studied structures of the knee (medial meniscus, lateral meniscus, anterior cruciate ligament, posterior cruciate ligament, and articular cartilage. RESULTS: Magnetic resonance imaging produced the following results regarding detection of lesions: medial meniscus: sensitivity 97.5%, specificity 92.9%, positive predictive value 93.9%, positive negative value 97%, likelihood positive ratio 13.7, likelihood negative ratio 0.02, and accuracy 95.3%; lateral meniscus: sensitivity 91.9%, specificity 93.6%, positive predictive value 92.7%, positive negative value 92.9%, likelihood positive ratio 14.3, likelihood negative ratio 0.08, and accuracy 93.6%; anterior cruciate ligament: sensitivity 99.0%, specificity 95.9%, positive predictive value 91.9%, positive negative value 99.5%, likelihood positive ratio 21.5, likelihood negative ratio 0.01, and accuracy 96.6%; posterior cruciate ligament: sensitivity 100%, specificity 99%, positive predictive value 80.0%, positive negative value 100%, likelihood positive ratio 100, likelihood negative ratio 0.01, and accuracy 99.6%; articular cartilage: sensitivity 76.1%, specificity 94.9%, positive predictive value 94.7%, positive negative value 76.9%, likelihood positive ratio 14.9, likelihood negative ratio 0.25, and accuracy 84.6%. CONCLUSION: Magnetic resonance imaging is a satisfactory diagnostic tool for evaluating meniscal and ligamentous lesions of the knee, but it is

  1. Magnetic resonance imaging in central nervous system tuberculosis

    International Nuclear Information System (INIS)

    Trivedi, Richa; Saksena, Sona; Gupta, Rakesh K

    2009-01-01

    Tuberculosis (TB) in any form is a devastating disease, which in its most severe form involves the central nervous system (CNS), with a high mortality and morbidity. Early diagnosis of CNS TB is necessary for appropriate treatment to reduce this morbidity and mortality. Routine diagnostic techniques involve culture and immunological tests of the tissue and biofluids, which are time-consuming and may delay definitive management. Noninvasive imaging modalities such as computed tomography (CT) scan and magnetic resonance imaging (MRI) are routinely used in the diagnosis of neurotuberculosis, with MRI offering greater inherent sensitivity and specificity than CT scan. In addition to conventional MRI imaging, magnetization transfer imaging, diffusion imaging, and proton magnetic resonance spectroscopy techniques are also being evaluated for better tissue characterization in CNS TB. The current article reviews the role of various MRI techniques in the diagnosis and management of CNS TB

  2. Magnetic resonance imaging in multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Hirayama, Keizo

    1989-01-01

    Magnetic resonance imaging (MRI) of the brain was performed in a total of 45 patients with multiple sclerosis (MS), comprising 27 with brain symptoms and 18 without it. The results were compared with X-ray computed tomography (CT). Some of the 45 MS patients were also examined by neurophysiological studies for comparison. MRI showed demyelinating plaques of the brain in a total of 31 patients (69%) - 20 symptomatic and 11 asymptomatic patients. For symptomatic patients, MRI was capable of detecting brain lesions in 6 (86%) of 7 acute stage patients and 14 (70%) of 20 non-acute stage patients. It was also capable of detecting brain lesions in 21 (70%) of 30 clinically definite MR patients and 10 (67%) of 15 clinically probable MS patients. Concurrently available X-ray CT revealed brain lesions in 9 symptomatic patients (33%) and one asymptomatic patient (6%). Visual evoked potentials examined in 31 patients showed abnormality in one (11%) of 9 patients without symptoms of optic neuritis and all (100%) of the other 22 patients with symptoms. In 19 evaluable patients, auditory brainstem responses were abnormal in one (11%) of 9 patients without brainstem symptoms and 3 (30%) of 10 patients with symptoms. MRI of the brain was far superior to X-ray CT, visual evoked potentials and auditory brainstem responses in detecting clinically unsuspected lesions. We proposed new diagnostic criteria including MRI findings of the brain in the Japanese MS diagnostic criteria. MRI of the spinal cord was performed in 12 MS patients with spinal cord symptoms by sagittal and coronal images. It demonstrated demyelinating lesions within the cervical and superior thoracic cord in 8 MS acute stage patients. Spinal cord lesions were longitudinally continuous as long as many spinal segments, with swelling in 6 patients and atrophy in 2 patients. MRI of spinal cord was useful in deciding superior and inferior limits of cord lesions and in visualizing cord swelling or atrophy. (Namekawa, K)

  3. Magnetic resonance imaging of the shoulder

    International Nuclear Information System (INIS)

    Ilieva, E.

    2015-01-01

    Full text: Magnetic resonance imaging (MRI) is an excellent non-invasive imaging tool that can complement the physical examination in the evaluation of traumatic and non-traumatic injuries of the shoulder. The superb soft tissue contrast and multiplanar capabilities of MRI make it a preferred modality to provide a global assessment of the soft tissue and osseous structures of the shoulder. Learning objectives: to review briefly the anatomy of the shoulder and the specificity of sequences and planes for MRI; to demonstrate the characteristic MR findings of some of the most common shoulder disorders; to indicate how MR arthrography (MRA) of the shoulder can add extra value to the diagnostic process; to outline a systematic approach to the interpretation of the shoulder MR examination. Choosing the most suitable sequences and planes as well as the thorough knowledge of the anatomic structures assist the correct diagnosis of the pathologic disorders of the shoulder which is of great importance for the precise treatment management, surgical versus conservative, as well as for the appropriate surgical approach, open versus arthroscopic

  4. Magnetic resonance imaging of the larynx

    International Nuclear Information System (INIS)

    Oleaga, L.

    2001-01-01

    Larynx and hypopharynx represent difficult anatomical structures to evaluate by imaging. Pathological processes inflammatory conditions and neoplasms are frequently found specially neoplasms. The most common tumor originating in this region is squamous cell carcinoma that represents 90%, of malignancies, magnetic Resonance Imaging (MRI) is used for staging of those tumors. In our study we evaluate the technique used for MRI studies as well as the anatomy of the larynx, hypopharynx and nodes and the different classification system used for neck nodes. We also analyze the different types of neoplasm that can be found being and malignant and the use of MRI for staging neoplasms. Clinical and laryngoscope staging of laryngeal tumors is not accurate if fails to demonstrate deep submucosal and laryngeal spaces invasion (pre-epi glottic. para laryngeal, para glottic, anterior commissures posterior commissure and sub glottis) as well as cartilage infiltration and extra laryngeal extension. We need accurate imaging diagnostic methods like MRI to evaluate the extension of tumors. (Author) 38 refs

  5. Gadolinium-DTPA in magnetic resonance tomography

    International Nuclear Information System (INIS)

    Prayer, L.; Imhof, H.; Stiglbauer, R.; Kramer, J.; Wimberger, D.

    1989-01-01

    Magnetic resonance tomography was performed on 158 patients with different indications before and after the administration of contrast medium. The MR examination included various plain T 1 and T 2 weighted spin echo sequences as well as T 1 weighted examinations after intravenous application of gadolinium-DTPA ('Magnevist', Schering AG) in a dosage of 0.1 mmol/kg body weight. The following conclusions were drawn: The sensitivity of MR in detecting brain tumors, acoustic neuromas and pituitary adenomas was improved considerably after the administration of 'Magnevist'. To diagnose the type of tumor, the criteria which apply to Gd-DPTA are similar to those used for iodine-containing contrast medium in CT. In about 2/3 rds of the cases, delineation of pathological tissues from surrounding edema and normal structures was better than in plain films. Hence, accurate, pretherapeutic staging of bronchial carcinomas and an exact definition of the expansion of the malignancies in the muscle-skeleton system were possible. In respect of tumors in the region of the base of the skull, we could omit T 2 -weighted sequences without noticeable loss of diagnostically relevant information; the examination time could thus be shortened by about 12 minutes. (orig.) [de

  6. Magnetic resonance diagnosis of aortic dissection

    International Nuclear Information System (INIS)

    Mukohara, Nobuhiko; Yoshida, Yutaka; Nakamura, Kazuo

    1986-01-01

    Magnetic resonance imaging (MRI) was performed in thirty-one patients with aortic dissection to evaluate its usefulness in diagnosing the site of communicating orifice between the true and false lumens and the presence of retrograde dissection. 1. MRI revealed the site of the entry as a defect in the intimal flap in the images of 12 of 15 patients (80 %). 2. The site of the communicating orifice between the true and false lumens in the abdominal aorta could be determined in six of eight patients (75 %). 3. MRI diagnosis of retrograde dissection was successful in three patients. 4. Cross-sectional analysis of the abdominal aorta based on the location of the true lumen revealed that the celiac and superior mesenteric arteries tended to arise from the true lumen when the latter was situated in the anterior part of the abdominal aorta. The right and left renal arteries arose from the true lumen when it was positioned anterolaterally. In conclusion, MRI was a useful diagnostic method for aortic dissection, especially for determining the site of entry in the thoracic aorta. The changes in signal intensity in the false lumen provided useful information for locating the communicating orifice between the true and false lumens and for diagnosis of retrograde dissection. Cross-sectional analysis of dissection in the abdominal aorta was useful for predicting the branching of the main arteries from the true or false lumen. (author)

  7. The diabetic foot: Magnetic resonance imaging evaluation

    International Nuclear Information System (INIS)

    Beltran, J.; Campanini, D.S.; Knight, C.; McCalla, M.

    1990-01-01

    Fourteen diabetic patients with suspected foot infection and/or neuropathic joint (Charcot Joint) were evaluated with magnetic resonance imaging (MRI) in an attempt to assess the extent of the infection and also to distinguish infection from the changes seen with neuroarthropathy. The majority of patients with infection had more than one site of involvement and the following diagnoses were made by MRI evaluation: Osteomyelitis (n=8), abscess (n=7), neuropathic joint (n=5), septic arthritis (n=4), and tenosynovitis (n=4). Clinical or surgical/pathological confirmation of the MRI diagnoses was obtained in all but nine sites of infection or cases of neuropathic joint. If the two diagnostic categories of septic arthritis and tenosynovitis are excluded, all but four of the MRI diagnoses were confirmed. A distinctive pattern for neuroarthropathy was identified in five cases, consisting of low signal intensity on T1- and T2-weighted images within the bone marrow space adjacent to the involved joint. We conclude that MRI is a valuable adjunct in the evaluation of the diabetic foot, and that it provides accurate information regarding the presence and extent of infection in this subset of patients. MRI has proven particularly helpful in differentiating neuroarthropathy from osteomyelitis. (orig.)

  8. Diagnostic accuracy of the Thessaly test, standardised clinical history and other clinical examination tests (Apley's, McMurray's and joint line tenderness) for meniscal tears in comparison with magnetic resonance imaging diagnosis.

    Science.gov (United States)

    Blyth, Mark; Anthony, Iain; Francq, Bernard; Brooksbank, Katriona; Downie, Paul; Powell, Andrew; Jones, Bryn; MacLean, Angus; McConnachie, Alex; Norrie, John

    2015-08-01

    Reliable non-invasive diagnosis of meniscal tears is difficult. Magnetic resonance imaging (MRI) is often used but is expensive and incidental findings are problematic. There are a number of physical examination tests for the diagnosis of meniscal tears that are simple, cheap and non-invasive. To determine the diagnostic accuracy of the Thessaly test and to determine if the Thessaly test (alone or in combination with other physical tests) can obviate the need for further investigation by MRI or arthroscopy for patients with a suspected meniscal tear. Single-centre prospective diagnostic accuracy study. Although the study was performed in a secondary care setting, it was designed to replicate the results that would have been achieved in a primary care setting. Two cohorts of patients were recruited: patients with knee pathology (n = 292) and a control cohort with no knee pathology (n = 75). Sensitivity, specificity and diagnostic accuracy of the Thessaly test in determining the presence of meniscal tears. Participants were assessed by both a primary care clinician and a musculoskeletal clinician. Both clinicians performed the Thessaly test, McMurray's test, Apley's test, joint line tenderness test and took a standardised clinical history from the patient. The Thessaly test had a sensitivity of 0.66, a specificity of 0.39 and a diagnostic accuracy of 54% when utilised by primary care clinicians. This compared with a sensitivity of 0.62, a specificity of 0.55 and diagnostic accuracy of 59% when used by musculoskeletal clinicians. The diagnostics accuracy of the other tests when used by primary care clinicians was 54% for McMurray's test, 53% for Apley's test, 54% for the joint line tenderness test and 55% for clinical history. For primary care clinicians, age and past history of osteoarthritis were both significant predictors of MRI diagnosis of meniscal tears. For musculoskeletal clinicians age and a positive diagnosis of meniscal tears on clinical history

  9. Magnetic Resonance Parkinsonism Index: diagnostic accuracy of a fully automated algorithm in comparison with the manual measurement in a large Italian multicentre study in patients with progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Nigro, Salvatore; Arabia, Gennarina; Antonini, Angelo; Weis, Luca; Marcante, Andrea; Tessitore, Alessandro; Cirillo, Mario; Tedeschi, Gioacchino; Zanigni, Stefano; Tonon, Caterina; Calandra-Buonaura, Giovanna; Pezzoli, Gianni; Cilia, Roberto; Zappia, Mario; Nicoletti, Alessandra; Cicero, Calogero Edoardo; Tinazzi, Michele; Tocco, Pierluigi; Cardobi, Nicolo; Quattrone, Aldo

    2017-01-01

    To investigate the reliability of a new in-house automatic algorithm for calculating the Magnetic Resonance Parkinsonism Index (MRPI), in a large multicentre study population of patients affected by progressive supranuclear palsy (PSP) or Parkinson's disease (PD), and healthy controls (HC), and to compare the diagnostic accuracy of the automatic and manual MRPI values. The study included 88 PSP patients, 234 PD patients and 117 controls. MRI was performed using both 3T and 1.5T scanners. Automatic and manual MRPI values were evaluated, and accuracy of both methods in distinguishing PSP from PD and controls was calculated. No statistical differences were found between automated and manual MRPI values in all groups. The automatic MRPI values differentiated PSP from PD with an accuracy of 95 % (manual MRPI accuracy 96 %) and 97 % (manual MRPI accuracy 100 %) for 1.5T and 3T scanners, respectively. Our study showed that the new in-house automated method for MRPI calculation was highly accurate in distinguishing PSP from PD. Our automatic approach allows a widespread use of MRPI in clinical practice and in longitudinal research studies. (orig.)

  10. Magnetic Resonance Parkinsonism Index: diagnostic accuracy of a fully automated algorithm in comparison with the manual measurement in a large Italian multicentre study in patients with progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Nigro, Salvatore [National Research Council, Institute of Bioimaging and Molecular Physiology, Catanzaro (Italy); Arabia, Gennarina [University ' ' Magna Graecia' ' , Institute of Neurology, Department of Medical and Surgical Sciences, Catanzaro (Italy); Antonini, Angelo; Weis, Luca; Marcante, Andrea [' ' Fondazione Ospedale San Camillo' ' - I.R.C.C.S, Parkinson' s Disease and Movement Disorders Unit, Venice-Lido (Italy); Tessitore, Alessandro; Cirillo, Mario; Tedeschi, Gioacchino [Second University of Naples, Department of Medical, Surgical, Neurological, Metabolic and Aging Sciences, Naples (Italy); Second University of Naples, MRI Research Center SUN-FISM, Naples (Italy); Zanigni, Stefano; Tonon, Caterina [Policlinico S. Orsola - Malpighi, Functional MR Unit, Bologna (Italy); University of Bologna, Department of Biomedical and Neuromotor Sciences, Bologna (Italy); Calandra-Buonaura, Giovanna [University of Bologna, Department of Biomedical and Neuromotor Sciences, Bologna (Italy); IRCCS Istituto delle Scienze Neurologiche di Bologna, Bologna (Italy); Pezzoli, Gianni; Cilia, Roberto [ASST G.Pini - CTO, ex ICP, Parkinson Institute, Milano (Italy); Zappia, Mario; Nicoletti, Alessandra; Cicero, Calogero Edoardo [University of Catania, Department ' ' G.F. Ingrassia' ' , Section of Neurosciences, Catania (Italy); Tinazzi, Michele; Tocco, Pierluigi [University Hospital of Verona, Department of Neurological and Movement Sciences, Verona (Italy); Cardobi, Nicolo [University Hospital of Verona, Institute of Radiology, Verona (Italy); Quattrone, Aldo [National Research Council, Institute of Bioimaging and Molecular Physiology, Catanzaro (Italy); University ' ' Magna Graecia' ' , Institute of Neurology, Department of Medical and Surgical Sciences, Catanzaro (Italy)

    2017-06-15

    To investigate the reliability of a new in-house automatic algorithm for calculating the Magnetic Resonance Parkinsonism Index (MRPI), in a large multicentre study population of patients affected by progressive supranuclear palsy (PSP) or Parkinson's disease (PD), and healthy controls (HC), and to compare the diagnostic accuracy of the automatic and manual MRPI values. The study included 88 PSP patients, 234 PD patients and 117 controls. MRI was performed using both 3T and 1.5T scanners. Automatic and manual MRPI values were evaluated, and accuracy of both methods in distinguishing PSP from PD and controls was calculated. No statistical differences were found between automated and manual MRPI values in all groups. The automatic MRPI values differentiated PSP from PD with an accuracy of 95 % (manual MRPI accuracy 96 %) and 97 % (manual MRPI accuracy 100 %) for 1.5T and 3T scanners, respectively. Our study showed that the new in-house automated method for MRPI calculation was highly accurate in distinguishing PSP from PD. Our automatic approach allows a widespread use of MRPI in clinical practice and in longitudinal research studies. (orig.)

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... vision or seizures help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... moveable examination table that slides into the center of the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  12. Embroidered Coils for Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Michael I. Newton

    2013-04-01

    Full Text Available Magnetic resonance imaging is a widely used technique for medical and materials imaging. Even though the objects being imaged are often irregularly shaped, suitable coils permitting the measurement of the radio-frequency signal in these systems are usually made of solid copper. One problem often encountered is how to ensure the coils are both in close proximity and conformal to the object being imaged. Whilst embroidered conductive threads have previously been used as antennae in mobile telecommunications applications, they have not previously been reported for use within magnetic resonance. In this paper we show that an embroidered single loop coil can be used in a commercial unilateral nuclear magnetic resonance system as an alternative to a solid copper. Data is presented showing the determination of both longitudinal (T1 and effective transverse (T2eff relaxation times for a flat fabric coil and the same coil conformed to an 8 cm diameter cylinder. We thereby demonstrate the principles required for the wider use of fabric based conformal coils within nuclear magnetic resonance and magnetic resonance imaging.

  13. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with high-grade glioma, a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dijken, Bart R.J. van [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); Laar, Peter Jan van; Hoorn, Anouk van der [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Holtman, Gea A. [University of Groningen, University Medical Center Groningen, Department of General Practice, Groningen (Netherlands)

    2017-10-15

    Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. (orig.)

  14. Diagnostic Performance of Breast Magnetic Resonance Imaging in Non-Calcified Equivocal Breast Findings: Results from a Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Barbara Bennani-Baiti

    Full Text Available To evaluate the performance of MRI for diagnosis of breast cancer in non-calcified equivocal breast findings.We performed a systematic review and meta-analysis of peer-reviewed studies in PubMed from 01/01/1986 until 06/15/2015. Eligible were studies applying dynamic contrast-enhanced breast MRI as an adjunct to conventional imaging (mammography, ultrasound to clarify equivocal findings without microcalcifications. Reference standard for MRI findings had to be established by histopathological sampling or imaging follow-up of at least 12 months. Number of true or false positives and negatives and other characteristics were extracted, and possible bias was determined using the QUADAS-2 applet. Statistical analyses included data pooling and heterogeneity testing.Fourteen out of 514 studies comprising 2,316 lesions met our inclusion criteria. Pooled diagnostic parameters were: sensitivity (99%, 95%-CI: 93-100%, specificity (89%, 95%-CI: 85-92%, PPV (56%, 95%-CI: 42-70% and NPV (100%, 95%-CI: 99-100%. These estimates displayed significant heterogeneity (P<0.001.Breast MRI demonstrates an excellent diagnostic performance in case of non-calcified equivocal breast findings detected in conventional imaging. However, considering the substantial heterogeneity with regard to prevalence of malignancy, problem solving criteria need to be better defined.

  15. Magnetic resonance angiography vs. angiography in tetralogy of Fallot.

    Science.gov (United States)

    Rao, Uppalapati Venkateswara; Vanajakshamma, Velam; Rajasekhar, Durgaprasad; Lakshmi, Amancharla Yadagiri; Reddy, Reddivari Niranjan

    2013-08-01

    : To determine whether gadolinium-enhanced three-dimensional magnetic resonance angiography can provide a noninvasive alternative to diagnostic catheterization for evaluation of pulmonary artery anatomy in tetralogy of Fallot. Thirty-five consecutive patients with tetralogy of Fallot, who attended the cardiology outpatient department between January 2008 and December 2009, were included in the study. There were 21 males and 14 females, with a mean age of 9 ± 4.15 years (range, 3-21 years). Thirty-two patients had tetralogy of Fallot with varying severities of valvular and infundibular stenosis. Three patients had tetralogy of Fallot with pulmonary atresia. All patients underwent both cardiac catheterization with X-ray angiography and 3-dimensional magnetic resonance angiography within one month. Measurements of right and left pulmonary arteries and aortopulmonary collaterals were equal by both methods. There was a good correlation between magnetic resonance angiography and catheterization measurements of branch pulmonary arteries. Gadolinium-enhanced three-dimensional magnetic resonance angiography can be used as a reliable noninvasive alternative to X-ray cineangiography for delineation of pulmonary arterial anatomy in sick infants and young children, obviating the need for catheterization.

  16. Evaluation of magnetic resonance velocimetry for steady flow.

    Science.gov (United States)

    Ku, D N; Biancheri, C L; Pettigrew, R I; Peifer, J W; Markou, C P; Engels, H

    1990-11-01

    Whole body magnetic resonance (MR) imaging has recently become an important diagnostic tool for cardiovascular diseases. The technique of magnetic resonance phase velocity encoding allows the quantitative measurement of velocity for an arbitrary component direction. A study was initiated to determine the ability and accuracy of MR velocimetry to measure a wide range of flow conditions including flow separation, three-dimensional secondary flow, high velocity gradients, and turbulence. A steady flow system pumped water doped with manganese chloride through a variety of test sections. Images were produced using gradient echo sequences on test sections including a straight tube, a curved tube, a smoothly converging-diverging nozzle, and an orifice. Magnetic resonance measurements of laminar and turbulent flows were depicted as cross-sectional velocity profiles. MR velocity measurements revealed such flow behavior as spatially varying velocity, recirculation and secondary flows over a wide range of conditions. Comparisons made with published experimental laser Doppler anemometry measurements and theoretical calculations for similar flow conditions revealed excellent accuracy and precision levels. The successful measurement of velocity profiles for a variety of flow conditions and geometries indicate that magnetic resonance imaging is an accurate, non-contacting velocimeter.

  17. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn; Creber, Sarah A.; Vrouwenvelder, Johannes S.; Johns, Michael L.

    2015-01-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system.

  18. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth\\'s magnetic field system.

  19. Generation of nuclear magnetic resonance images

    International Nuclear Information System (INIS)

    Beckmann, N.X.

    1986-01-01

    Two generation techniques of nuclear magnetic resonance images, the retro-projection and the direct transformation method are studied these techniques are based on the acquisition of NMR signals which phases and frequency components are codified in space by application of magnetic field gradients. The construction of magnet coils is discussed, in particular a suitable magnet geometry with polar pieces and air gap. The obtention of image contrast by T1 and T2 relaxation times reconstructed from generated signals using sequences such as spin-echo, inversion-recovery and stimulated echo, is discussed. The mathematical formalism of matrix solution for Bloch equations is also presented. (M.C.K.)

  20. Susceptibility effects in nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ziener, Christian Herbert

    2008-01-01

    The properties of dephasing and the resulting relaxation of the magnetization are the basic principle on which all magnetic resonance imaging methods are based. The signal obtained from the gyrating spins is essentially determined by the properties of the considered tissue. Especially the susceptibility differences caused by magnetized materials (for example, deoxygenated blood, BOLD-effect) or magnetic nanoparticles are becoming more important for biomedical imaging. In the present work, the influence of such field inhomogeneities on the NMR-signal is analyzed. (orig.)

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic ... the radiologist if your child has any serious health problems or has recently had surgery. Some conditions, ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, ... to the heart muscle evaluate findings following cardiovascular surgery In the abdominal and pelvic region, MRI is ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... material called gadolinium, which is less likely to cause an allergic reaction than iodinated contrast material. Tell ... magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so you should let the radiologist know about them. ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so the radiologist should be aware of them. Parents ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if your child has asthma. The contrast ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... the MRI equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... does the equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... an MRI scan, but this is rare. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so you should let the ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... lodged in the eyes are particularly important. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so the radiologist should be ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. You will lie ... your skin at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. Your child will ... skin irritation at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... regular daily routine and have him/her take food and medications as usual. Some MRI examinations may ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... if your child has any implanted medical or electronic devices. Inform your doctor and the technologist prior ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... cord is needed, MRI is useful because of its ability to see through the skull and the ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography ( ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... allergies and whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it ... if there is any possibility that they are pregnant. MRI has been used for scanning patients since ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... fluid spaces within the brain (ventricles) causes of epilepsy (seizure) hemorrhage in selected trauma patients certain chronic ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... two-way intercom. Many MRI centers allow a parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it ... the exam if your child has a known allergy to contrast material. Your child should wear loose, ...

  14. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  15. Magnetic resonance enterography in pediatric celiac disease.

    Science.gov (United States)

    Koc, Gonca; Doganay, Selim; Sevinc, Eylem; Deniz, Kemal; Chavhan, Govind; Gorkem, Sureyya B; Karacabey, Neslihan; Dogan, Mehmet S; Coskun, Abdulhakim; Aslan, Duran

    To assess if magnetic resonance enterography is capable of showing evidence/extent of disease in pediatric patients with biopsy-proven celiac disease by comparing with a control group, and to correlate the magnetic resonance enterography findings with anti-endomysial antibody level, which is an indicator of gluten-free dietary compliance. Thirty-one pediatric patients (mean age 11.7±3.1 years) with biopsy-proven celiac disease and 40 pediatric patients as a control group were recruited in the study. The magnetic resonance enterography images of both patients with celiac disease and those of the control group were evaluated by two pediatric radiologists in a blinded manner for the mucosal pattern, presence of wall thickening, luminal distention of the small bowel, and extra-intestinal findings. Patient charts were reviewed to note clinical features and laboratory findings. The histopathologic review of the duodenal biopsies was re-conducted. The mean duration of the disease was 5.6±1.8 years (range: 3-7.2 years). In 24 (77%) of the patients, anti-endomysial antibody levels were elevated (mean 119.2±66.6RU/mL). Magnetic resonance enterography revealed normal fold pattern in all the patients. Ten (32%) patients had enlarged mesenteric lymph nodes. Although a majority of the patients had elevated anti-endomysial antibody levels indicating poor dietary compliance, magnetic resonance enterography did not show any mucosal abnormality associated with the inability of magnetic resonance enterography to detect mild/early changes of celiac disease in children. Therefore, it may not be useful for the follow-up of pediatric celiac disease. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  16. Development of automatic extraction of the corpus callosum from magnetic resonance imaging of the head and examination of the early dementia objective diagnostic technique in feature analysis

    International Nuclear Information System (INIS)

    Kodama, Naoki; Kaneko, Tomoyuki

    2005-01-01

    We examined the objective diagnosis of dementia based on changes in the corpus callosum. We examined midsagittal head MR images of 17 early dementia patients (2 men and 15 women; mean age, 77.2±3.3 years) and 18 healthy elderly controls (2 men and 16 women; mean age, 73.8±6.5 years), 35 subjects altogether. First, the corpus callosum was automatically extracted from the MR images. Next, early dementia was compared with the healthy elderly individuals using 5 features of the straight-line methods, 5 features of the Run-Length Matrix, and 6 features of the Co-occurrence Matrix from the corpus callosum. Automatic extraction of the corpus callosum showed an accuracy rate of 84.1±3.7%. A statistically significant difference was found in 6 of the 16 features between early dementia patients and healthy elderly controls. Discriminant analysis using the 6 features demonstrated a sensitivity of 88.2% and specificity of 77.8%, with an overall accuracy of 82.9%. These results indicate that feature analysis based on changes in the corpus callosum can be used as an objective diagnostic technique for early dementia. (author)

  17. A Novel Diagnostic Aid for Detection of Intra-Abdominal Adhesions to the Anterior Abdominal Wall Using Dynamic Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    David Randall

    2016-01-01

    Full Text Available Introduction. Abdominal adhesions can cause serious morbidity and complicate subsequent operations. Their diagnosis is often one of exclusion due to a lack of a reliable, non-invasive diagnostic technique. Development and testing of a candidate technique are described below. Method. During respiration, smooth visceral sliding motion occurs between the abdominal contents and the walls of the abdominal cavity. We describe a technique involving image segmentation and registration to calculate shear as an analogue for visceral slide based on the tracking of structures throughout the respiratory cycle. The presence of an adhesion is attributed to a resistance to visceral slide resulting in a discernible reduction in shear. The abdominal movement due to respiration is captured in sagittal dynamic MR images. Results. Clinical images were selected for analysis, including a patient with a surgically confirmed adhesion. Discernible reduction in shear was observed at the location of the adhesion while a consistent, gradually changing shear was observed in the healthy volunteers. Conclusion. The technique and its validation show encouraging results for adhesion detection but a larger study is now required to confirm its potential.

  18. A Novel Diagnostic Aid for Detection of Intra-Abdominal Adhesions to the Anterior Abdominal Wall Using Dynamic Magnetic Resonance Imaging.

    Science.gov (United States)

    Randall, David; Fenner, John; Gillott, Richard; Ten Broek, Richard; Strik, Chema; Spencer, Paul; Bardhan, Karna Dev

    2016-01-01

    Introduction. Abdominal adhesions can cause serious morbidity and complicate subsequent operations. Their diagnosis is often one of exclusion due to a lack of a reliable, non-invasive diagnostic technique. Development and testing of a candidate technique are described below. Method. During respiration, smooth visceral sliding motion occurs between the abdominal contents and the walls of the abdominal cavity. We describe a technique involving image segmentation and registration to calculate shear as an analogue for visceral slide based on the tracking of structures throughout the respiratory cycle. The presence of an adhesion is attributed to a resistance to visceral slide resulting in a discernible reduction in shear. The abdominal movement due to respiration is captured in sagittal dynamic MR images. Results. Clinical images were selected for analysis, including a patient with a surgically confirmed adhesion. Discernible reduction in shear was observed at the location of the adhesion while a consistent, gradually changing shear was observed in the healthy volunteers. Conclusion. The technique and its validation show encouraging results for adhesion detection but a larger study is now required to confirm its potential.

  19. A Novel Diagnostic Aid for Detection of Intra-Abdominal Adhesions to the Anterior Abdominal Wall Using Dynamic Magnetic Resonance Imaging

    Science.gov (United States)

    Randall, David; Fenner, John; Gillott, Richard; ten Broek, Richard; Strik, Chema; Spencer, Paul; Bardhan, Karna Dev

    2016-01-01

    Introduction. Abdominal adhesions can cause serious morbidity and complicate subsequent operations. Their diagnosis is often one of exclusion due to a lack of a reliable, non-invasive diagnostic technique. Development and testing of a candidate technique are described below. Method. During respiration, smooth visceral sliding motion occurs between the abdominal contents and the walls of the abdominal cavity. We describe a technique involving image segmentation and registration to calculate shear as an analogue for visceral slide based on the tracking of structures throughout the respiratory cycle. The presence of an adhesion is attributed to a resistance to visceral slide resulting in a discernible reduction in shear. The abdominal movement due to respiration is captured in sagittal dynamic MR images. Results. Clinical images were selected for analysis, including a patient with a surgically confirmed adhesion. Discernible reduction in shear was observed at the location of the adhesion while a consistent, gradually changing shear was observed in the healthy volunteers. Conclusion. The technique and its validation show encouraging results for adhesion detection but a larger study is now required to confirm its potential. PMID:26880884

  20. Magnetic resonance imaging of popliteal artery pathologies

    International Nuclear Information System (INIS)

    Holden, Andrew; Merrilees, Stephen; Mitchell, Nicola; Hill, Andrew

    2008-01-01

    This paper illustrates examples of popliteal artery pathologies imaged with contrast enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI) at a single tertiary referral centre. Popliteal artery pathologies were identified in 1710 patients referred over a 6-year period with symptoms suggesting lower limb arterial occlusive disease. Common pathologies such as atherosclerotic occlusive disease, thromboemboli and aneurysm disease are discussed as well as unusual pathologies such as cystic adventitial disease, mycotic aneurysm and arterial entrapment. The combination of CE-MRA and the excellent soft tissue resolution of MRI allow detailed evaluation of arterial and peri-arterial pathologies, and facilitate appropriate management decisions

  1. Magnetic resonance imaging of popliteal artery pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Holden, Andrew [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: andrewh@adhb.govt.nz; Merrilees, Stephen [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: smerrilees@adhb.govt.nz; Mitchell, Nicola [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: nmit010@ec.auckland.ac.nz; Hill, Andrew [Department of Vascular Surgery, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: ahill@adhb.govt.nz

    2008-07-15

    This paper illustrates examples of popliteal artery pathologies imaged with contrast enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI) at a single tertiary referral centre. Popliteal artery pathologies were identified in 1710 patients referred over a 6-year period with symptoms suggesting lower limb arterial occlusive disease. Common pathologies such as atherosclerotic occlusive disease, thromboemboli and aneurysm disease are discussed as well as unusual pathologies such as cystic adventitial disease, mycotic aneurysm and arterial entrapment. The combination of CE-MRA and the excellent soft tissue resolution of MRI allow detailed evaluation of arterial and peri-arterial pathologies, and facilitate appropriate management decisions.

  2. Magnetic elliptical polarization of Schumann resonances

    International Nuclear Information System (INIS)

    Sentman, D.D.

    1987-01-01

    Measurements of orthogonal, horizontal components of the magnetic field in the ELF range obtained during September 1985 show that the Schumann resonance eigenfrequencies determined separately for the north-south and east-west magnetic components differ by as much as 0.5 Hz, suggesting that the underlying magnetic signal is not linearly polarized at such times. The high degree of magnetic ellipticity found suggests that the side multiplets of the Schumann resonances corresponding to azimuthally inhomogeneous normal modes are strongly excited in the highly asymmetric earth-ionosphere cavity. The dominant sense of polarization over the measurement passband is found to be right-handed during local daylight hours, and to be left-handed during local nighttime hours. 16 references

  3. Features of laser spectroscopy and diagnostics of plasma ions in high magnetic fields

    International Nuclear Information System (INIS)

    Semerok, A F; Fomichev, S V

    2003-01-01

    Laser induced fluorescence and laser absorption spectroscopies of plasma ions in high magnetic fields have been investigated. Both the high degree of Zeeman splitting of the resonant transitions and the ion rotational movement drastically change the properties of the resonance interaction of the continuous wave laser radiation with ions in highly magnetized plasma. Numerical solution of the density matrix equation for a dissipative two-level system with time-dependent detuning from resonance was used to analyse this interaction. A theoretical simulation was performed and compared with the experimental results obtained from the laser spectroscopy diagnostics of barium plasma ions in high magnetic fields in the several tesla range

  4. Proton magnetic resonance spectroscopy and perfusion magnetic resonance imaging in the evaluation of musculoskeletal tumors

    International Nuclear Information System (INIS)

    Costa, Flavia Martins; Setti, Marcela; Vianna, Evandro Miguelote; Domingues, Romulo Cortes; Meohas, Walter; Rezende, Jose Francisco; Gasparetto, Emerson Leandro

    2009-01-01

    Objective: To assess the role of proton magnetic resonance spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in the differentiation between malignant and benign musculoskeletal tumors. Materials And Methods: Fifty-five patients with musculoskeletal tumors (27 malignant and 28 benign) were studied. The examinations were performed in a 1.5 T magnetic resonance scanner with standard protocol, and single voxel proton magnetic resonance spectroscopy with 135 msec echo time. The dynamic contrast study was performed using T1-weighted gradient-echo sequence after intravenous gadolinium injection. Time signal intensity curves and slope values were calculated. The statistical analysis was performed with the Levene's test, followed by a Student's t-test, besides the Pearson's chi-squared and Fischer's exact tests. Results: Proton magnetic resonance spectroscopy sensitivity, specificity and accuracy were, respectively, 87.5%, 92.3% and 90.9% (p < 0.0001). Statistically significant difference was observed in the slope (%/min) between benign (mean, 27.5%/min) and malignant (mean, 110.9%/min) lesions (p < 0.0001). Conclusion: The time-intensity curve and slope values using dynamic-enhanced perfusion magnetic resonance imaging in association with the presence of choline peak demonstrated by single voxel magnetic resonance spectroscopy study are useful in the differentiation between malignant and benign musculoskeletal tumors. (author)

  5. Magnetic resonance appearance of monoclonal gammopathies of unknown significance and multiple myeloma. The GRI Study Group.

    Science.gov (United States)

    Bellaïche, L; Laredo, J D; Lioté, F; Koeger, A C; Hamze, B; Ziza, J M; Pertuiset, E; Bardin, T; Tubiana, J M

    1997-11-01

    A prospective multicenter study. To evaluate the use of magnetic resonance imaging, in the differentiation between monoclonal gammopathies of unknown significance and multiple myeloma. Although multiple myeloma has been studied extensively with magnetic resonance imaging, to the authors' knowledge, no study has evaluated the clinical interest of magnetic resonance imaging in the differentiation between monoclonal gammopathies of unknown significance and multiple myeloma. The magnetic resonance examinations of the thoracolumbar spine in 24 patients with newly diagnosed monoclonal gammopathies of unknown significance were compared with those performed in 44 patients with newly diagnosed nontreated multiple myeloma. All findings on magnetic resonance examination performed in patients with monoclonal gammopathies of unknown significance were normal, whereas findings on 38 (86%) of the 44 magnetic resonance examinations performed in patients with multiple myeloma were abnormal. Magnetic resonance imaging can be considered as an additional diagnostic tool in differentiating between monoclonal gammopathies of unknown significance and multiple myeloma, which may be helpful when routine criteria are not sufficient. An abnormal finding on magnetic resonance examination in a patient with monoclonal gammopathies of unknown significance should suggest the diagnosis of multiple myeloma after other causes of marrow signal abnormalities are excluded. Magnetic resonance imaging also may be proposed in the long-term follow-up of monoclonal gammopathies of unknown significance when a new biologic or clinical event suggests the diagnosis of malignant monoclonal gammopathy.

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... ill effects on pregnant women or their unborn babies. However, because the unborn baby will be in a strong magnetic field, pregnant ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... epilepsy (seizure) hemorrhage in selected trauma patients certain chronic conditions, such as multiple sclerosis disorders of the ... a very small chance of irritation of your skin at the site of the IV tube insertion. Some ... Images related to Magnetic ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic ... patient to have an allergy to a gadolinium-based contrast agent used for MRI than the iodine- ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... which they come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... which they come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... MRI equipment look like? How does the procedure work? How is the ... use to diagnose medical conditions. MRI uses a powerful magnetic field, radio frequency ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... use to diagnose medical conditions. MRI uses a powerful magnetic field, radio frequency ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... to see, hear and speak with your child at all times using a two-way intercom. Many MRI centers allow a parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... able to see, hear and speak with you at all times using a two-way intercom. Many MRI centers allow a friend or parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and other cranial structures that are clearer and more detailed than other imaging methods. This exam does not use ionizing radiation and may require an injection of a ...

  17. Low-Field Magnetic Resonance Imaging of Canine Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Z. Adamiak* and M. Jaskólska and A. Pomianowski1

    2012-01-01

    Full Text Available The aim of presented study was to evaluate selected surface spine coil, and low-field magnetic resonance (MR selected sequences in diagnosing hydrocephalus in dogs. This paper discusses 19 dogs (14 canine patients with hydrocephalus and 5 healthy dogs, of five breeds, subjected to low-field magnetic resonance imaging (MRI of hydrocephalus. Area of the lateral ventricles and brain were examined in dogs with hydrocephalus using low-field MRI (at 0.25 Tesla. The MRI of FSE REL, SE, FLAIR, STIR, 3D HYCE, T3DT1, GE STIR 3D and 3D SHARC sequences with an indication of the most effective sequences are described. Additionally, coils for MR were compared, and models for infusion anesthesia were described. As a result of performed study all estimated sequences were diagnostically useful. However, spinal coil No. 2 (ESAOTE was the most optimal for examining and positioning the cranium.

  18. Magnetic resonance cholangiopancreatography. The fine art of bilio-pancreatic imaging.

    Science.gov (United States)

    Adamek, H E; Breer, H; Layer, G; Riemann, J F

    2002-01-01

    With the introduction of endoscopic retrograde cholangio-pancreatography in the early 1970s, gastroenterologists have a lot of diagnostic options in the biliopancreatic system to their disposal. Meanwhile, magnetic resonance cholangiopancreatography (MRCP) has become a competitive replacement for diagnostic ERCP with the advantage of avoiding complications related to endoscopic techniques. Mounting evidence suggests that both MRCP and MRI (magnetic resonance imaging) have a profound influence of diagnostic algorithms in a variety of hepatobiliary and pancreatic diseases. Copyright 2002 S. Karger AG, Basel and IAP

  19. Complications after liver transplantation: evaluation with magnetic resonance imaging, magnetic resonance cholangiography, and 3-dimensional contrast-enhanced magnetic resonance angiography in a single session

    International Nuclear Information System (INIS)

    Boraschi, P.; Donati, F.; Gigoni, R.; Salemi, S.; Urbani, L.; Filipponi, F.; Falaschi, F.; Bartolozzi, C.

    2008-01-01

    To evaluate a comprehensive magnetic resonance imaging (MRI) protocol as noninvasive diagnostic modality for simultaneous detection of parenchymal, biliary, and vascular complications after liver transplantation. Fifty-two liver transplant recipients suspected to have parenchymal, biliary, and (or) vascular complications underwent our MRI protocol at 1.5T unit using a phased array coil. After preliminary acquisition of axial T 1 w and T 2 w sequences, magnetic resonance cholangiography (MRC) was performed through a breath-hold, thin- and thick-slab, single-shot T 2 w sequence in the coronal plane. Contrast-enhanced magnetic resonance angiography (CEMRA) was obtained using a 3-dimensional coronal spoiled gradient-echo sequence, which enabled acquisition of 32 partitions 2.0 mm thick. A fixed dose of 20 ml gadobenate dimeglumine was administered at 2 mL/s. A post-contrast T 1 w sequence was also performed. Two observers in conference reviewed source images and 3-dimensional reconstructions to determine the presence of parenchymal, biliary, and vascular complications. MRI findings were correlated with surgery, endoscopic retrograde cholangiography (ERC), biopsy, digital subtraction angiography (DSA), and imaging follow-up. MRI revealed abnormal findings in 32 out of 52 patients (61%), including biliary complications (anastomotic and nonanastomotic strictures, and lithiasis) in 31, vascular disease (hepatic artery stenosis and thrombosis) in 9, and evidence of hepatic abscess and hematoma in 2. ERC confirmed findings of MRC in 30 cases, but suggested disease underestimation in 2. DSA confirmed 7 magnetic resonance angiogram (MRA) findings, but suggested disease overestimation in 2. MRI combined with MRC and CEMRA can provide a comprehensive assessment of parenchymal, biliary, and vascular complications in most recipients of liver transplantation. (author)

  20. Magnetic resonance investigation of magnetic-labeled baker's yeast cells

    International Nuclear Information System (INIS)

    Godoy Morais, J.P.M.; Azevedo, R.B.; Silva, L.P.; Lacava, Z.G.M.; Bao, S.N.; Silva, O.; Pelegrini, F.; Gansau, C.; Buske, N.; Safarik, I.; Safarikova, M.; Morais, P.C.

    2004-01-01

    In this study, the interaction of DMSA-coated magnetite nanoparticles (5 and 10 nm core-size) with Saccharomyces cerevisae was investigated using magnetic resonance (MR) and transmission electron microscopy (TEM). The TEM micrographs revealed magnetite nanoparticles attached externally to the cell wall. The MR data support the strong interaction among the nanoparticles supported by the cells. A remarkable shift in the resonance field was used as signature of particle attachment to the cell wall

  1. resonant inverter supplied interior permanent magnet (ipm)

    African Journals Online (AJOL)

    user

    [5] Zhenyue Hong, “DC-voltage link resonant inverters”, Department of Electrical and. Electronic Engineering University of. Canterbury, New Zealand. [6] Kalyan Kumar Halder, Naruttam Kumar Roy and B.C. Ghosh, “Position Sensorless. Control for an Interior Permanent Magnet. Synchronous Motor SVM Drive with ANN.

  2. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    1996-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing

  3. Pharyngeal branchial cyst: magnetic resonance findings

    Energy Technology Data Exchange (ETDEWEB)

    Cerezal, L.; Canga, A. [Department of Radiology of the ' Santa Cruz' Hospital Liencres, Cantabria (Spain); Morales, C. [Department of Otorhinolaryngology of the ' Sierrallana' Hospital Torrelavega, Cantabria (Spain); Abascal, F.; Usamentiaga, E.; Bustamante, M. [Department of Radiology of the University Hospital ' Marques de Valdecilla' , Av. de Valdecilla s/n Santander 39008 (Spain); Olcinas, O. [Department of Pathology of the University Hospital ' Marques de Valdecilla' , Av. de Valdecilla s/n Santander 39008 (Spain)

    1998-11-01

    An unusual case of pharyngeal cyst in a 25-year-old man studied by Magnetic Resonance (MR) is described. Anatomic location and pathological findings indicated the second branchial pouch origin. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  4. Pharyngeal branchial cyst: magnetic resonance findings

    International Nuclear Information System (INIS)

    Cerezal, L.; Canga, A.; Morales, C.; Abascal, F.; Usamentiaga, E.; Bustamante, M.; Olcinas, O.

    1998-01-01

    An unusual case of pharyngeal cyst in a 25-year-old man studied by Magnetic Resonance (MR) is described. Anatomic location and pathological findings indicated the second branchial pouch origin. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  5. Numerical methods in electron magnetic resonance

    International Nuclear Information System (INIS)

    Soernes, A.R.

    1998-01-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system

  6. Numerical methods in electron magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Soernes, A.R

    1998-07-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system.

  7. Magnetic resonance angiography in meningovascular syphilis

    Energy Technology Data Exchange (ETDEWEB)

    Gallego, J [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Soriano, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Zubieta, J L [Servicio de Neuroradiologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Delgado, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Villanueva, J A [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain)

    1994-04-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  8. Cryogenic Preamplifiers for Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Johansen, Daniel H.; Sanchez-Heredia, Juan D.; Petersen, Jan R.

    2018-01-01

    Pursuing the ultimate limit of detection in magnetic resonance imaging (MRI) requires cryogenics to decrease the thermal noise of the electronic circuits. As cryogenic coils for MRI are slowly emerging cryogenic preamplifiers are required to fully exploit their potential. A cryogenic preamplifier...

  9. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  10. Magnetic resonance imaging of xanthomatous meningioma

    International Nuclear Information System (INIS)

    Katayama, Y.; Tsubokawa, T.; Tanaka, A.; Koshinaga, M.; Nemoto, N.

    1993-01-01

    A case of meningioma with extensive xanthomatous metaplasia occurring in the left frontal convexity of a 37-year-old woman is reported. The tumour was demonstrated as a hypodense mass with minimal enhancement on CT. Our findings suggest that magnetic resonance imaging may provide a clue to the diagnosis of meningiomas with extensive xanthomatous metaplasia when CT is less specific. (orig.)

  11. Evaluation of nuclear magnetic resonance spectroscopy variability

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe Rodrigues; Salmon, Carlos Ernesto Garrido, E-mail: garrido@ffclrp.usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filisofia, Ciencias e Letras; Otaduy, Maria Concepcion Garcia [Universidade de Sao Paulo (FAMUS/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Departamento de Radiologia

    2014-11-01

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  12. Vascular anatomy in angiography for magnetic resonance

    International Nuclear Information System (INIS)

    Charry Lopez, Marco Luciano; Rivera Gomez, Juan Enrique

    1998-01-01

    A review of basic anatomical concepts and main variants, as well as some anatomical anomalies of the central nervous system vascularity, these concepts are considered essential for the interpretation of magnetic resonance angiography with time-of-flight (TOF) and phase-contrast (PC) methods

  13. Magnetic resonance imaging in obstetric diagnosis.

    Science.gov (United States)

    Weinreb, J C; Lowe, T W; Santos-Ramos, R; Cunningham, F G; Parkey, R

    1985-01-01

    Five patients with abnormal pregnancies were examined with ultrasound (US) and magnetic resonance imaging (MR). Three had a malformed fetus, 1 had a molar pregnancy, and 1 had an ovarian mass. Both maternal and fetal structures were clearly shown, although fetal motion may have resulted in image degradation in some cases. The authors suggest that MR may be useful in obstetric diagnosis.

  14. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive ... possibility that you’re pregnant tell your doctor as well. On the day of your exam, it’s ...

  15. Magnetic resonance imaging in sudden deafness

    International Nuclear Information System (INIS)

    Ramos, Hugo Valter Lisboa; Barros, Flavia Alencar; Penido, Norma de Oliveira; Souza, Ana Claudia Valerio de; Yamaoka, Wellington Yugo; Yamashita, Helio

    2005-01-01

    The etiology of sudden deafness can remain undetermined despite extensive investigation. This study addresses the value of magnetic resonance imaging in the analysis of sudden deafness patients.Study Design: transversal cohort.Material And Method: In a prospective study, 49 patients attended at otolaryngology emergency room of Federal University of Sao Paulo - Escola Paulista de Medicina, from April 2001 to May 2003, were submitted to magnetic resonance imaging.Results: Magnetic Resonance abnormalities were seen in 23 (46.9%) patients and revealed two tumors suggestive of meningioma, three vestibular schwannomas, thirteen microangiopathic changes of the brain and five (21.7%) pathological conditions of the labyrinth.Conclusion: Sudden deafness should be approached as a symptom common to different diseases. The presence of cerebellopontine angle tumors in 10.2% of our cases, among other treatable causes, justifies the recommendation of gadolinium-enhanced magnetic resonance use, not only to study the auditory peripheral pathway, but to study the whole auditory pathway including the brain. (author)

  16. Magnetic resonance studies of solid polymers

    International Nuclear Information System (INIS)

    Lenk, R.

    1969-01-01

    This paper is a review of the application of nuclear magnetic resonance (NMR) to solid polymers. In the first, theoretical part, the elements of the theory of NMR, which are necessary for the study of the properties of solid polymers are discussed: the moments method, nuclear relaxation and the distribution of correlation times. In the second part the experimental results are presented. (author) [fr

  17. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  18. Magnetic resonance imaging of the knee

    International Nuclear Information System (INIS)

    Nederveen, D.; Bakker, C.J.G.; Scholten, F.G.; Feldberg, N.A.M.; Postma, J.H.; Vis, H. van der

    1989-01-01

    Sixteen patients suspected of having meniscal lesions, were examined bt magnetic resonance (MR) and arthroscopy, MR and arthroscopy corelate well for meniscal and cruciate ligament lesions. Damage of the articular cartilage was, however, not detected by MR (author). 15 refs.; 4 figs.; 1 tab

  19. Intralabyrinthine schwannoma shown by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Saeed, S.R.; Birzgalis, A.R.; Ramsden, R.T.

    1994-01-01

    Intralabyrinthine schwannomas are rare benign tumours which present with progressive or fluctuant audiovestibular symptoms and may mimic Menieres disease. The size and position of these lesions make preoperative diagnosis unusual and most are discovered incidentally at labyrinthectomy. A case is reported which was diagnosed on magnetic resonance imaging and confirmed at surgery. (orig.)

  20. Magnetic resonance imaging of semicircular canals.

    Science.gov (United States)

    Sbarbati, A; Leclercq, F; Zancanaro, C; Antonakis, K

    1992-01-01

    The present paper reports the results of the first investigation of the semicircular canals in a living, small animal by means of high spatial resolution magnetic resonance imaging. This procedure is noninvasive and allows identification of the endolymphatic and perilymphatic spaces yielding a morphology quite consistent with direct anatomical examination. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:1506290