WorldWideScience

Sample records for magnetic recording media

  1. Recording performances in perpendicular magnetic patterned media

    International Nuclear Information System (INIS)

    Asbahi, M; Moritz, J; Dieny, B; Gourgon, C; Perret, C; Van de Veerdonk, R J M

    2010-01-01

    We report on the recording performances and signal-to-noise ratio (SNR) analyses of perpendicular magnetic bit-patterned media. Two different types of magnetic samples are investigated. They differ by the way that they were patterned (nano-imprint versus e-beam lithography) as well as their magnetic properties (Co/Pt multilayers and CoCrPt alloy are the recording layers).Using a contact read/write quasi-static tester, we were able to characterize the write windows, the bit error rates and measure the SNR. The influence of magnetic properties and media microstructure on the writing processes is studied. We show also that the lithographical method used to replicate the media induces more or less noise due to structural distributions.

  2. The investigation of nanostructures of magnetic recording media by TEM

    International Nuclear Information System (INIS)

    Peng Yingguo; Ohkubo, Tadakatsu; Laughlin, David E.

    2003-01-01

    Diverse applications of transmission electron microscopy techniques used in investigating the nanostructures of magnetic recording materials are presented. Specimen preparation methods are discussed for the specific case of magnetic thin film recording media. Investigations of the crystallographic orientation, grain size and distribution, and interfacial nanostructures are presented

  3. Method to manufacture bit patterned magnetic recording media

    Science.gov (United States)

    Raeymaekers, Bart; Sinha, Dipen N

    2014-05-13

    A method to increase the storage density on magnetic recording media by physically separating the individual bits from each other with a non-magnetic medium (so-called bit patterned media). This allows the bits to be closely packed together without creating magnetic "cross-talk" between adjacent bits. In one embodiment, ferromagnetic particles are submerged in a resin solution, contained in a reservoir. The bottom of the reservoir is made of piezoelectric material.

  4. Characteristics of thermally assisted magnetic recording in granular perpendicular media

    International Nuclear Information System (INIS)

    Shiino, Hirotaka; Kawana, Mayumi; Miyashita, Eiichi; Hayashi, Naoto; Watanabe, Sadayuki

    2009-01-01

    The effect of thermally assisted magnetic recording using granular perpendicular media with a single-pole-trimmed head has been investigated. A read/write experiment using a spin stand in which the media were heated by laser irradiation demonstrated that the track average amplitude strongly depends on both the position of the write head relative to the center of the laser spot in the down-track direction and on the laser power. Although the signal-to-noise ratio increased with the coercivity of the media, the increment was small; this is thought to be caused by an increase in the switching field distribution of the media with temperature. Our results suggest that the magnetic constant of the media must be optimized with respect to the temperature of writing in order for high-density thermally assisted magnetic recording to be realized

  5. Simulations of magnetic hysteresis loops for dual layer recording media

    Science.gov (United States)

    Fal, T. J.; Plumer, M. L.; Whitehead, J. P.; Mercer, J. I.; van Ek, J.; Srinivasan, K.

    2013-05-01

    A Kinetic Monte-Carlo algorithm is applied to examine MH loops of dual-layer magnetic recording media at finite temperature and long time scales associated with typical experimental measurements. In contrast with standard micromagnetic simulations, which are limited to the ns-μs time regime, our approach allows for the direct calculation of magnetic configurations over periods from minutes to years. The model is used to fit anisotropy and coupling parameters to experimental data on exchange-coupled composite media which are shown to deviate significantly from standard micromagnetic results. Sensitivities of the loops to anisotropy, inter-layer exchange coupling, temperature, and sweep rate are examined.

  6. Density limits imposed by the microstructure of magnetic recording media

    International Nuclear Information System (INIS)

    Richter, H.J.

    2009-01-01

    The fundamental limit of magnetic recording density on conventional media is set by the grain size. Once this grain size limit is reached, only a reduction of the grain size allows an increased SNR and thus an increased areal density. It is shown that, whilst maintaining thermal stability, scaling demands that the required anisotropy energy density K is proportional to the areal density, or the square of the areal density if the medium thickness reaches the critical thickness 4√(A/K) (A is the exchange stiffness of the material). Recording onto materials with such a high anisotropy requires some form of a write-assist. It is furthermore shown that the grain size limit cannot be obtained with intergranular exchange present, and six different requirements are listed that constitute ideal media. An alternative path for increasing areal density of magnetic recording is to use patterned media, where each bit contains only one grain. In this case, written-in errors dominate system performance and the maximum achievable areal density is estimated to be about 6 Tbit/in 2 . Patterned media need to exhibit narrow distributions of their physical and structural properties with standard deviations of the order of 5% or less

  7. Influence of mechanical scratch on the recorded magnetization stability of perpendicular recording media

    International Nuclear Information System (INIS)

    Nagano, Katsumasa; Sasaki, Syota; Futamoto, Masaaki

    2010-01-01

    Stability of recorded magnetization of hard disk drives (HDDs) is influenced by external environments, such as temperature, magnetic field, etc. Small scratches are frequently formed on HDD medium surface upon contacts with the magnetic head. Influence of temperature and mechanical scratch on the magnetization structure stability of perpendicular recording media was investigated by using a magnetic force microscope. The magnetic bit shape started to change at around 300 0 C for an area with no scratches, whereas for the area near a shallow mechanical scratch it started to change at a lower temperature around 250 0 C. An analysis of magnetization structure under an influence of temperature and mechanical scratch is carried out for the magnetization structure variation and recorded magnetization strength.

  8. Correlations between the orientation of magnetic recording media determined by Moessbauer spectroscopy and magnetic methods

    International Nuclear Information System (INIS)

    Pott, R.A.; Koch, W.; Leitner, L.

    1986-01-01

    The orientation of the easy magnetization axis of magnetic particles is a key parameter of the recording performance of magnetic recording media. Usually the orientation is measured by magnetic methods, but the applicability of the Moessbauer Spectroscopy has also been shown in the past. The authors show and discuss the correlations between the results obtained by magnetic and Moessbauer measurements for the example of several magnetic tapes. They demonstrate that by a combination of both methods one is even able to estimate the mean canting angles distribution width of the easy axis of magnetization. (Auth.)

  9. Magnetic properties of soft layer/FePt-MgO exchange coupled composite Perpendicular recording media

    Institute of Scientific and Technical Information of China (English)

    Yin Jin-Hua; Takao Suzuki; Pan Li-Qing

    2008-01-01

    The magnetic properties of exchange coupled composite(ECC)media that are composed of perpendicular magnetic recording media FePt-MgO and two kinds of soft layers have been studied by using an x-ray diffractometer,a polar Kerr magneto-optical system(PMOKE)and a vibrating sample magnetometer(VSM).The results show that ECC media can reduce the coercivities of perpendicular magnetic recording media FePt-MgO.The ECC media with granular-type soft layers have weaker exchange couplings between magnetic grains and the magnetization process,for ECC media of this kind mainly follow the Stoner-Wohlfarth model.

  10. High resolution magnetic force microscopy: instrumentation and application for recording media

    NARCIS (Netherlands)

    Porthun, Steffen; Porthun, S.

    This thesis describes aspects of the use of magnetic force microscopy for the study of magnetic recording media. The maximum achievable storage density in magnetic recording is limited by the magnetic reversal behaviour of the medium and by the stability of the written information. The shape and

  11. Preparation and recording characteristics of granular-type perpendicular magnetic recording media with thin intermediate layer

    International Nuclear Information System (INIS)

    Shintaku, K.; Kiya, T.

    2008-01-01

    Granular-type media with thin Ru intermediate layer were prepared on a highly oriented high-B s FeCo soft underlayer (SUL). A CoPt-TiO 2 recording layer on a Ru intermediate layer of only 2 nm had high-crystal orientation, high H c of 6.5 kOe, and a high squareness ratio (SQ) of 0.99. The magnetic property of the SUL was also good. The recording performance was measured for the media with different Ru intermediate thicknesses by using a single-pole-type (SPT) head. The media had large reproduced output even for the Ru intermediate layer thickness of 2 nm

  12. Preparation and recording characteristics of granular-type perpendicular magnetic recording media with thin intermediate layer

    Energy Technology Data Exchange (ETDEWEB)

    Shintaku, K. [Akita Research Institute of Advanced Technology, Akita Prefectural R and D Center, 4-21 Sanuki, Araya, Akita 010-1623 (Japan)], E-mail: shintaku@ait.pref.akita.jp; Kiya, T. [Akita Research Institute of Advanced Technology, Akita Prefectural R and D Center, 4-21 Sanuki, Araya, Akita 010-1623 (Japan)

    2008-11-15

    Granular-type media with thin Ru intermediate layer were prepared on a highly oriented high-B{sub s} FeCo soft underlayer (SUL). A CoPt-TiO{sub 2} recording layer on a Ru intermediate layer of only 2 nm had high-crystal orientation, high H{sub c} of 6.5 kOe, and a high squareness ratio (SQ) of 0.99. The magnetic property of the SUL was also good. The recording performance was measured for the media with different Ru intermediate thicknesses by using a single-pole-type (SPT) head. The media had large reproduced output even for the Ru intermediate layer thickness of 2 nm.

  13. Influence of Temperature and Mechanical Scratch on the Recorded Magnetization Stability of Longitudinal and Perpendicular Recording Media

    International Nuclear Information System (INIS)

    Nagano, Katsumasa; Tobari, Kousuke; Futamoto, Masaaki

    2011-01-01

    Stability of recorded magnetization of hard disk drive (HDD) is influenced by external environments, such as temperature and magnetic field. Small scratches are frequently formed on HDD medium surface upon contacts with the magnetic head. The influences of temperature and mechanical scratch on the magnetization structure stability are investigated for longitudinal and perpendicular recording media by using a magnetic force microscope. PMR media remained almost unchanged up to about 300 deg. C for the area with no scratches, whereas the areas near and under mechanical scratches started to change around 250 deg. C. The magnetization structure of LMR media started to change at about 100 degrees lower temperature under mechanical scratches when compared with no scratch areas. A quantitative analysis of magnetization structure variation is carried out by measuring the recorded magnetization strength difference estimated from the MFM images observed for a same sample area before and after exposing the sample to different temperatures.

  14. Thermal effects and in-plane magnetic anisotropy in thin-film recording media

    International Nuclear Information System (INIS)

    Ajan, Antony; Abarra, E.N.; Acharya, B.R.; Inomata, A.; Okamoto, I.; Shinohara, M.

    2003-01-01

    The effect of thermal activation on the in-plane magnetic anisotropy [measured as orientation ratio (OR)] of granular longitudinal magnetic recording media is investigated. Temperature and time dependent studies were made on media with different magnetic layer thicknesses. We find that OR is independent of temperature for a stable medium but shows a large increase with temperature for thermally unstable media. At low temperatures and high field sweep rates, the OR values are found to be the same, independent of the magnetic layer thickness. The unique value when thermal activation is reduced is consistent with the high population of the cobalt c axes along the texturing direction as the origin of anisotropy

  15. Application of magnetic printing method to hard-disk media with double recording layers

    International Nuclear Information System (INIS)

    Ono, Takuya; Kuboki, Yoshiyuki; Ajishi, Yoshifumi; Saito, Akira

    2003-01-01

    The magnetic printing method, which can duplicate soft magnetic patterns containing digital information such as servosignals formed on a master disk onto recording media, enables signals to be written to hard-disk media having high coercivities above 6000 Oe. We propose the application of the magnetic printing method to a hard-disk medium having double recording layers, one layer of which has high coercivity and is to be printed with digital information. This double recording layer medium is a hard-disk medium that has a magnetic read-only-memory (MROM) layer. In this study, we demonstrated a method for printing to this medium, which has MROM, and discussed the magnetic properties and recording performances of this medium

  16. Analysis of microstructures for Co/Pd multilayer perpendicular magnetic recording media with carbon underlayer

    International Nuclear Information System (INIS)

    Asahi, T.; Kuramochi, K.; Kawaji, J.; Onoue, T.; Osaka, T.; Saigo, M.

    2001-01-01

    The effect of amorphous carbon underlayer thickness on the microstructure of the Co/Pd multilayer perpendicular magnetic recording media was investigated. From the magnetic force microscopy observation in the AC-demagnetized state of the Co/Pd multilayer media, the magnetic cluster size was observed to effectively decrease with an increase in carbon underlayer thickness, where the higher coercivity and the higher S/N ratio of the Co/Pd multilayer media were obtained with the thicker underlayer. Furthermore, the distribution of [1 1 1] orientation of FCC-Pd became broader, and the grain size decreased with an increase in the carbon underlayer thickness. These effects caused the magnetic exchange decoupling of Co/Pd multilayer media. We suggested that the change of microstructure was directly related to the surface roughness of the amorphous carbon underlayer

  17. Annealing effect on magnetic property and recording performance of [FePt/MgO]n perpendicular magnetic recording media

    International Nuclear Information System (INIS)

    Suzuki, Takao; Zhang, Zhengang; Singh, Amarendra K.; Yin, Jinhua; Perumal, A.; Osawa, Hiroshi

    2005-01-01

    Granular-type FePt perpendicular magnetic recording media with (001)-texture, obtained by annealing FePt/MgO multilayer films, are fabricated onto 2.5-in glass discs. For the sake of spin-stand testing, the coercivity of FePt films is carefully modulated by controlling the annealing conditions. With annealing, exchange coupling between FePt grains is decreased, indicated by the reductions in α value and activation volume. FePt ordering process is dependent on initial FePt/MgO multilayer structures, which governs the optimum annealing condition regarding coercivities and α(=4π(dM/dH)H=Hc). The SNR ratio exhibits a sensitive dependence on initial FePt/MgO multilayer structures as well as annealing conditions

  18. Magnetic force microscopy of thin film media for high density magnetic recording

    NARCIS (Netherlands)

    Porthun, Steffen; Porthun, S.; Abelmann, Leon; Lodder, J.C.

    1998-01-01

    This paper discusses various aspect of magnetic force microscopy (MFM) for use in the field of high density magnetic recording. After an introduction of the most important magnetic imaging techniques, an overview is given of the operation and theory of MFM. The developments in instrumentation, MFM

  19. A multi-functional testing instrument for heat assisted magnetic recording media

    International Nuclear Information System (INIS)

    Yang, H. Z.; Chen, Y. J.; Leong, S. H.; An, C. W.; Ye, K. D.; Hu, J. F.; Yin, M. J.

    2014-01-01

    With recent developments in heat assisted magnetic recording (HAMR), characterization of HAMR media is becoming very important. We present a multi-functional instrument for testing HAMR media, which integrates HAMR writing, reading, and a micro-magneto-optic Kerr effect (μ-MOKE) testing function. A potential application of the present instrument is to make temperature dependent magnetic property measurement using a pump-probe configuration. In the measurement, the media is heated up by a heating (intense) beam while a testing (weak) beam is overlapped with the heating beam for MOKE measurement. By heating the media with different heating beam power, magnetic measurements by MOKE at different temperatures can be performed. Compared to traditional existing tools such as the vibrating sample magnetometer, the present instrument provides localized and efficient heating at the measurement spot. The integration of HAMR writing and μ-MOKE system can also facilitate a localized full investigation of the magnetic media by potential correlation of HAMR head independent write/read performance to localized magnetic properties

  20. Exchange coupled CoPt/FePtC media for heat assisted magnetic recording

    Science.gov (United States)

    Dutta, Tanmay; Piramanayagam, S. N.; Ru, Tan Hui; Saifullah, M. S. M.; Bhatia, C. S.; Yang, Hyunsoo

    2018-04-01

    L10 FePtC granular media are being studied as potential future magnetic recording media and are set to be used in conjunction with heat assisted magnetic recording (HAMR) to enable recording at write fields within the range of current day recording heads. Media structures based on a FePtC storage layer and a capping layer can alleviate the switching field distribution (SFD) requirements of HAMR and reduce the noise originating from the writing process. However, the current designs suffer from SFD issues due to high temperature writing. To overcome this problem, we study a CoPt/FePtC exchange coupled composite structure, where FePtC serves as the storage layer and CoPt (with higher Curie temperature, Tc) as the capping layer. CoPt remains ferromagnetic at near Tc of FePtC. Consequently, the counter exchange energy from CoPt would reduce the noise resulting from the adjacent grain interactions during the writing process. CoPt/FePtC bilayer samples with different thicknesses of CoPt were investigated. Our studies found that CoPt forms a continuous layer at a thickness of 6 nm and leads to considerable reduction in the saturation field and its distribution.

  1. Scanning laser techniques for dynamic thermo-magnetic recording onto stationary media

    Energy Technology Data Exchange (ETDEWEB)

    Clegg, Warwick; Jenkins, David; Helian, Na; Windmill, James; Windmill, Robert; Atkinson, Ron; Hendren, Bill; Wright, C. David

    2002-09-01

    Scanning laser microscopes (SLMs) have been used to characterise the magnetic properties of materials for some time (J. Magn. Magn. Mater. 95(1) (1991); IEEE Trans. Magn. 31(6 Pt. 1) (1995)). An SLM has been designed to facilitate a number of operating modes: both for writing and reading magneto-optical data. The current SLM is capable of thermo-magnetically recording bits onto magneto-optical thin films. Unlike previous SLMs, the current instrument has been designed to write bits both statically and dynamically onto stationary media. It will be used to write to magneto-optic (MO) disk material thermo-magnetically prior to imaging. Images may be derived from the longitudinal and polar magneto-optic Kerr effects, which are wavelength dependent, using the appropriate laser wavelength. In this paper the two configurations for dynamic recording are described.

  2. Scanning laser techniques for dynamic thermo-magnetic recording onto stationary media

    International Nuclear Information System (INIS)

    Clegg, Warwick; Jenkins, David; Helian, Na; Windmill, James; Windmill, Robert; Atkinson, Ron; Hendren, Bill; Wright, C. David

    2002-01-01

    Scanning laser microscopes (SLMs) have been used to characterise the magnetic properties of materials for some time (J. Magn. Magn. Mater. 95(1) (1991); IEEE Trans. Magn. 31(6 Pt. 1) (1995)). An SLM has been designed to facilitate a number of operating modes: both for writing and reading magneto-optical data. The current SLM is capable of thermo-magnetically recording bits onto magneto-optical thin films. Unlike previous SLMs, the current instrument has been designed to write bits both statically and dynamically onto stationary media. It will be used to write to magneto-optic (MO) disk material thermo-magnetically prior to imaging. Images may be derived from the longitudinal and polar magneto-optic Kerr effects, which are wavelength dependent, using the appropriate laser wavelength. In this paper the two configurations for dynamic recording are described

  3. Laser Texturing of Magnetic Recording Media Final Report CRADA No. TSV-1298-96

    Energy Technology Data Exchange (ETDEWEB)

    Hackel, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Marshall, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-16

    The Commercial Laser Systems Group at LLNL developed a concept for patterning of computer magnetic recording discs. Magnetic recording media require texturing over areas designated for contact in order to minimize friction with data transducing heads. In fabricating a hard disk, an aluminum nickel-phosphorous substrate was polished to a specular finish then a mechanical means was used to roughen an annular area intended to be the head contact band. In a previous patent (US Patent 5,062,021) it was proposed that the focused output of a low power laser with short pulse length could be used to generate the textured pattern. However, the patterned area typically required 75,000 textured spots that needed to be rapidly (less than 10 seconds) printed with good uniformity. A means to achieve the accurate placement and uniform profile, as well as a meaningfully rapid process time, was not discussed in the referenced patent. The LLNL team devised a system that could rapidly and inexpensively accomplish the texturing.

  4. Double-layered perpendicular magnetic recording media of granular-type FePt-MgO films

    International Nuclear Information System (INIS)

    Zhang Zhengang; Singh, Amarendra K.; Yin Jinhua; Perumal, A.; Suzuki, Takao

    2005-01-01

    The recording performance of double-layered granular-type FePt-MgO perpendicular magnetic recording media fabricated onto glass discs by sputtering is investigated. The (0 0 1)-textured FePt granular films are obtained by annealing FePt/MgO multilayers. Three different multilayer structures are compared in their magnetic properties and recording SNR performances. To evaluate thermal stability property of these granular-type FePt disks, the time-dependent magnetic force microscope (MFM) signal from the written bits on one of these disks is recorded in the temperature range 25-200 degree sign C. The signal decay at high observation temperature is interpreted based on the temperature dependence of magnetic anisotropy (K u )

  5. Real time monitoring of superparamagnetic nanoparticle self-assembly on surfaces of magnetic recording media

    International Nuclear Information System (INIS)

    Ye, L.; Pearson, T.; Crawford, T. M.; Qi, B.; Cordeau, Y.; Mefford, O. T.

    2014-01-01

    Nanoparticle self-assembly dynamics are monitored in real-time by detecting optical diffraction from an all-nanoparticle grating as it self-assembles on a grating pattern recorded on a magnetic medium. The diffraction efficiency strongly depends on concentration, pH, and colloidal stability of nanoparticle suspensions, demonstrating the nanoparticle self-assembly process is highly tunable. This metrology could provide an alternative for detecting nanoparticle properties such as colloidal stability

  6. Fabrication and characterization of nano-particulate PtCo media for ultra-high density perpendicular magnetic recording

    International Nuclear Information System (INIS)

    Newman, Dave M; Wears, M Lesley; Jollie, Michael; Choo, Desmond

    2007-01-01

    The year-on-year growth in areal recording density maintained now for half a century by the hard disk industry has required a corresponding reduction in the size of the magnetic grains comprising the storage media employed. Grain dimensions are now such that the performance of materials which thus far have served the industry well can no longer be maintained as further reduction in their volume risks breaching the superparamagnetic limit with the attendant loss of data integrity. The high magnetocrystalline anisotropy of the Ll 0 phase of PtCo allows particles as small as 4 nm diameter to remain magnetically stable in the elevated temperature environment typical of disk drive systems. A non-interacting dispersion of nanomagnetic particles suspended in an inert non-magnetic host such that each has its anisotropy axis directed perpendicular to the surface of the medium now constitutes the new ideal for a recording medium. Fabrication by a novel combination of conventional sputtering and thermal processing technologies of a medium closely approximating this ideal is demonstrated. An optimized two-stage fabrication process produces a near mono-dispersion of particles with magnetic activation volumes centred about 5 x 10 23 and crystallized in the L1 0 phase with an orientated tetragonal structure. The characteristics of this medium are discussed as a function of composition and crystalline structure. In the absence of a thermally assisted recording head, experiments are conducted on a degraded form of the medium that is shown to support perpendicular recording at linear densities in excess of 240 kfci (D50 point)

  7. Thermal transfer recording media

    Science.gov (United States)

    Takei, T.; Taniguchi, M.; Fukushima, H.; Yamaguchi, Y.; Shinozuka, M.; Seikohsha, K. K. Suwa

    1988-08-01

    The recording media consist of more than or one coloring layer and a layer containing a flame retardant to ensure noncombustibility and good thermal transfer. Thus, a PET film was coated on a side with a compound containing Vylon 290 (polyester resin), AFR-1021 (decabromodiphenyl oxide) 8 and Polysafe 60 (Sb oxide), and coated on the other side with a compound containing carnauba wax, HNP-9 (paraffin wax), EV-410 (ethylene-vinyl acetate copolymer), and Cu phthalocyanine to give a thermal transfer recording medium which showed good noncombustibility and antiblocking properties, and provided high quality images.

  8. Head-disk Interface Study for Heat Assisted Magnetic Recording (HAMR) and Plasmonic Nanolithography for Patterned Media

    Science.gov (United States)

    Xiong, Shaomin

    The magnetic storage areal density keeps increasing every year, and magnetic recording-based hard disk drives provide a very cheap and effective solution to the ever increasing demand for data storage. Heat assisted magnetic recording (HAMR) and bit patterned media have been proposed to increase the magnetic storage density beyond 1 Tb/in2. In HAMR systems, high magnetic anisotropy materials are recommended to break the superparamagnetic limit for further scaling down the size of magnetic bits. However, the current magnetic transducers are not able to generate strong enough field to switch the magnetic orientations of the high magnetic anisotropy material so the data writing is not able to be achieved. So thermal heating has to be applied to reduce the coercivity for the magnetic writing. To provide the heating, a laser is focused using a near field transducer (NFT) to locally heat a ~(25 nm)2 spot on the magnetic disk to the Curie temperature, which is ~ 400 C-600°C, to assist in the data writing process. But this high temperature working condition is a great challenge for the traditional head-disk interface (HDI). The disk lubricant can be depleted by evaporation or decomposition. The protective carbon overcoat can be graphitized or oxidized. The surface quality, such as its roughness, can be changed as well. The NFT structure is also vulnerable to degradation under the large number of thermal load cycles. The changes of the HDI under the thermal conditions could significantly reduce the robustness and reliability of the HAMR products. In bit patterned media systems, instead of using the continuous magnetic granular material, physically isolated magnetic islands are used to store data. The size of the magnetic islands should be about or less than 25 nm in order to achieve the storage areal density beyond 1 Tb/in2. However, the manufacture of the patterned media disks is a great challenge for the current optical lithography technology. Alternative lithography

  9. Effects of intermediate layers on magnetic properties and read/write performance in CoCrPt perpendicular recording media with an FeHfN soft magnetic underlayer

    International Nuclear Information System (INIS)

    Hong, D.H.; Shin, J.N.; Lee, T.D.; Hong, S.Y.; Lee, H.J.

    2003-01-01

    In this study, the effects of CoCrPtTa and CoCrPtB magnetic intermediate layers (ILs) on the magnetic properties and read/write performance of CoCrPt/soft magnetic layer perpendicular recording media were investigated. Even though the perpendicular coercivity of the media with these ILs was reduced by 500 Oe, these media still showed a low exchange slope of 1.4 and a large negative nucleation field of about -1000 Oe. Additionally, the reduced grain size of the media with these IL was observed by transmission electron microscopy. From the read/write test, these media with ILs showed improved performance of 3-5 dB higher signal-to-noise ratio and overwrite ratio (OW) compared to the media without ILs. These enhancements could be attributed to the reduction of grain size of the magnetic layer and weakening of the intergranular interaction between grains by insertion of the IL

  10. Improved (0 0 1)-texture of FePt-C for heat-assisted magnetic recording media by insertion of Cr buffer layer

    Energy Technology Data Exchange (ETDEWEB)

    Shiroyama, T.; Wang, J.; Felicia, A.; Takahashi, Y.K.; Hono, K., E-mail: kazuhiro.hono@nims.go.jp

    2017-06-15

    Highlights: • Improvement of (0 0 1)-texture of prototype FePt-C granular films for heat heat assisted magnetic recording media. • Insertion of Cr buffer layer improves the crystallographic textures of the MgO underlayers, thereby reduces in-plane component in the FePt-C recording layer. • The growth in the grain size of the MgO underlayer as well as the (0 0 1)-texture of the MgO underlayer are the key factor in reducing the in-plane component in the FePt-C recording layer. - Abstract: FePt-C granular films deposited on MgO underlayers are the prototype media for heat-assisted magnetic recording. To reduce the in-plane magnetic component in the FePt-C media, we investigated the effect of Cr buffer layers on the crystallographic textures of the MgO underlayers and the resultant magnetic properties of the FePt-C layers. By growing a MgO underlayer on a Cr buffer layer, the (0 0 1) texture of the MgO underlayer is improved, on which the in-plane component of a FePt-C film is substantially reduced. We conclude that the growth in the grain size of the MgO underlayer is the key factor in reducing the in-plane component in the FePt-C recording layer.

  11. Nano-patterning of perpendicular magnetic recording media by low-energy implantation of chemically reactive ions

    International Nuclear Information System (INIS)

    Martin-Gonzalez, M.S.; Briones, F.; Garcia-Martin, J.M.; Montserrat, J.; Vila, L.; Faini, G.; Testa, A.M.; Fiorani, D.; Rohrmann, H.

    2010-01-01

    Magnetic nano-patterning of perpendicular hard disk media with perpendicular anisotropy, but preserving disk surface planarity, is presented here. Reactive ion implantation is used to locally modify the chemical composition (hence the magnetization and magnetic anisotropy) of the Co/Pd multilayer in irradiated areas. The procedure involves low energy, chemically reactive ion irradiation through a resist mask. Among N, P and As ions, P are shown to be most adequate to obtain optimum bit density and topography flatness for industrial Co/Pd multilayer media. The effect of this ion contributes to isolate perpendicular bits by destroying both anisotropy and magnetic exchange in the irradiated areas. Low ion fluences are effective due to the stabilization of atomic displacement levels by the chemical effect of covalent impurities.

  12. Studies in perpendicular magnetic recording

    Science.gov (United States)

    Valcu, Bogdan F.

    of media. Perpendicular media has more non-uniform grains than typical longitudinal media; the difference might appear due to the higher symmetry (related to the crystallographic orientation). The SNR is affected in great measure by the amount of exchange interaction between the grains. The intergranular coupling in CoCr alloys---typical for recording media---is reduced by Cr diffusion at the grain boundary. Micromagnetic modeling with an elementary discrete cell of atomic dimensions is used to calculate the magnetization variations through the grain boundary. An effective exchange interaction parameter is determined in terms of details of the chemical composition.

  13. Mechanism of coercivity enhancement by Ag addition in FePt-C granular films for heat assisted magnetic recording media

    Energy Technology Data Exchange (ETDEWEB)

    Varaprasad, B. S. D. Ch. S.; Takahashi, Y. K., E-mail: takahashi.yukiko@nims.go.jp; Wang, J.; Hono, K. [National Institute for Materials Science (NIMS), 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Ina, T.; Nakamura, T.; Ueno, W.; Nitta, K.; Uruga, T. [Japan Synchrotron Radiation Research Institute (JASRI/SPring-8), 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2014-06-02

    We investigated the Ag distribution in a FePtAg-C granular film that is under consideration for a heat assisted magnetic recording medium by aberration-corrected scanning transmission electron microscope-energy dispersive X-ray spectroscopy and X-ray absorption fine structure. Ag is rejected from the core of FePt grains during the deposition, forming Ag-enriched shell surrounding L1{sub 0}-ordered FePt grains. Since Ag has no solubility in both Fe and Pt, the rejection of Ag induces atomic diffusions thereby enhancing the kinetics of the L1{sub 0}-order in the FePt grains.

  14. Full micromagnetics of recording on patterned media

    International Nuclear Information System (INIS)

    Fidler, J.; Schrefl, T.; Suess, D.; Ertl, O.; Kirschner, M.; Hrkac, G.

    2006-01-01

    Numerical micromagnetics of the bit writing process revealed the theoretical limits for remanence, coercive field, switching behaviour at a short time scale of less than 1 ns for patterned recording media. We discuss our recent results concerning the influence of the granular microstructure on the fast switching processes of typical CoCrPtX, FePt and CoPd thin films used for high density magnetic recording with longitudinal and perpendicular anisotropy. In detail, we will show that the degree of the exchange coupling between neighbouring grains, the grain size and its distribution and the offset between recording head and bit structure finally control the magnetization reversal properties of the individual bits

  15. Magnetic fields in diffuse media

    CERN Document Server

    Pino, Elisabete; Melioli, Claudio

    2015-01-01

    This volume presents the current knowledge of magnetic fields in diffuse astrophysical media. Starting with an overview of 21st century instrumentation to observe astrophysical magnetic fields, the chapters cover observational techniques, origin of magnetic fields, magnetic turbulence, basic processes in magnetized fluids, the role of magnetic fields for cosmic rays, in the interstellar medium and for star formation. Written by a group of leading experts the book represents an excellent overview of the field. Nonspecialists will find sufficient background to enter the field and be able to appreciate the state of the art.

  16. MFM study of magnetic interaction between recording and soft magnetic layers

    International Nuclear Information System (INIS)

    Honda, Yukio; Tanahashi, Kiwamu; Hirayama, Yoshiyuki; Kikukawa, Atsushi; Futamoto, Masaaki

    2001-01-01

    Magnetic force microscopy was used to study the magnetic interaction between the recording and the soft magnetic layers in double-layer perpendicular media by observing the magnetization structure from the soft magnetic layer side. There was a strong magnetic interaction between the recording and the soft magnetic layers. Introducing a thin nonmagnetic intermediate layer between the two layers greatly reduced the magnetic interaction and drastically reduced the medium noise

  17. The foundations of magnetic recording

    CERN Document Server

    Mallinson, John C

    1993-01-01

    This expanded and updated new edition provides a comprehensive overview of the science and technology of magnetic recording. In the six years since the publication of the first edition, the magnetic recording and storage industry has burgeoned with the introduction of a host of new ideas and technologies. His book contains a discussion of almost every technologically important aspect of recording.* Continas complete coverage of the current technology of magnetic recording and storage* Written in a non-mathematical but scientifically accurate style* Permits intelligent evaluat

  18. Surface structure of MgO underlayer with Ti diffusion for (002 oriented L10 FePt-based heat assisted magnetic recording media

    Directory of Open Access Journals (Sweden)

    Sintaro Hinata

    2018-05-01

    Full Text Available Surface morphology of the MgO layer and magnetic properties of FePt-C layer deposited on the MgO were investigated for the FePt-based heat assisted magnetic recording media. Stacking structure of the underlayer for the FePt-C layer was MgO (0-5 nm/Cr80Mn20 (0-30 nm/Cr50Ti50 (0-50 nm/glass sub.. Surface observation result for the MgO film by using an atomic force microscope revealed the existence of nodules with a height of about 2 nm and a network-like convex structure with a height difference of about sub nm (boundary wall, BW on the MgO crystal grain boundary. Density of the nodules largely depends on the surface roughness of the CrTi layer, RaCrTi and it is suppressed from 10 to 2/0.5 μm2 by reducing RaCrTi from 420 to 260 pm. Height of the BW depends on thickness of the MgO layer, tMgO and it can be suppressed by reducing tMgO to less than 4 nm. From the cross-sectional energy dispersive x-ray mapping, it is clarified that the BW is formed by atomic diffusion of Ti atoms from CrTi layer due to the substrate heating process, and a compound consists of Mg, Ti and O atoms. This BW can be used as a template to magnetically isolate the FePt column in the FePt-based granular film, such as FePt-SiO2, if the size of the BW is reduced to less than 10 nm. M-H loop of the FePt-C granular film deposited on the underlayer showed that the nodule and BW induce oxidation of the FePt grains, and reduction of intergranular exchange coupling.

  19. Surface structure of MgO underlayer with Ti diffusion for (002) oriented L10 FePt-based heat assisted magnetic recording media

    Science.gov (United States)

    Hinata, Sintaro; Jo, Shin; Saito, Shin

    2018-05-01

    Surface morphology of the MgO layer and magnetic properties of FePt-C layer deposited on the MgO were investigated for the FePt-based heat assisted magnetic recording media. Stacking structure of the underlayer for the FePt-C layer was MgO (0-5 nm)/Cr80Mn20 (0-30 nm)/Cr50Ti50 (0-50 nm)/glass sub.. Surface observation result for the MgO film by using an atomic force microscope revealed the existence of nodules with a height of about 2 nm and a network-like convex structure with a height difference of about sub nm (boundary wall, BW) on the MgO crystal grain boundary. Density of the nodules largely depends on the surface roughness of the CrTi layer, RaCrTi and it is suppressed from 10 to 2/0.5 μm2 by reducing RaCrTi from 420 to 260 pm. Height of the BW depends on thickness of the MgO layer, tMgO and it can be suppressed by reducing tMgO to less than 4 nm. From the cross-sectional energy dispersive x-ray mapping, it is clarified that the BW is formed by atomic diffusion of Ti atoms from CrTi layer due to the substrate heating process, and a compound consists of Mg, Ti and O atoms. This BW can be used as a template to magnetically isolate the FePt column in the FePt-based granular film, such as FePt-SiO2, if the size of the BW is reduced to less than 10 nm. M-H loop of the FePt-C granular film deposited on the underlayer showed that the nodule and BW induce oxidation of the FePt grains, and reduction of intergranular exchange coupling.

  20. Optimisation of applied field pulses for microwave assisted magnetic recording

    Directory of Open Access Journals (Sweden)

    Simon John Greaves

    2017-05-01

    Full Text Available Grains in a recording medium experience field pulses from a write head during recording. In general, a short head field rise time and a square pulse shape have been viewed as optimal. This work investigates the optimum field pulse shape for microwave assisted magnetic recording on single layer and ECC media. A square pulse was found to give the best recording performance on single layer media, but an initially negative field pulse increasing at a constant rate was more suitable for ECC media.

  1. Oblique evaporation of CO80Ni20 for magnetic recording

    NARCIS (Netherlands)

    Abelmann, Leon

    Tape and disc media have their own specific fields of application in magnetic, magneto-optic and optical recording. Tape media are commonly used where a large storage capacity is needed. To meet the increasing demands for larger storage capacities industry has investigated the possibility to use the

  2. Fundamental Scientific Problems in Magnetic Recording

    Energy Technology Data Exchange (ETDEWEB)

    Schulthess, T.C.; Miller, M.K.

    2007-06-27

    Magnetic data storage technology is presently leading the high tech industry in advancing device integration--doubling the storage density every 12 months. To continue these advancements and to achieve terra bit per inch squared recording densities, new approaches to store and access data will be needed in about 3-5 years. In this project, collaboration between Oak Ridge National Laboratory (ORNL), Center for Materials for Information Technology (MINT) at University of Alabama (UA), Imago Scientific Instruments, and Seagate Technologies, was undertaken to address the fundamental scientific problems confronted by the industry in meeting the upcoming challenges. The areas that were the focus of this study were to: (1) develop atom probe tomography for atomic scale imaging of magnetic heterostructures used in magnetic data storage technology; (2) develop a first principles based tools for the study of exchange bias aimed at finding new anti-ferromagnetic materials to reduce the thickness of the pinning layer in the read head; (3) develop high moment magnetic materials and tools to study magnetic switching in nanostructures aimed at developing improved writers of high anisotropy magnetic storage media.

  3. Discoveries that guided the beginning of perpendicular magnetic recording

    International Nuclear Information System (INIS)

    Iwasaki, S.

    2001-01-01

    The speculations and discoveries that guided the beginning of perpendicular magnetic recording, which have never been systematically discussed before, are described in this paper. Especially, four important discoveries of perpendicular magnetization, Co-Cr film, effect of double layered medium, and complementarity law are described in detail. The studies on thin film media and recording mechanisms at short wavelengths aiming at the advancement of longitudinal magnetic recording in the 1960's lead to the realization of the new perpendicular magnetic recording through these discoveries. None of these works was on any list of research targets in the 1960's. The study of perpendicular magnetic recording has taught us that research should proceed systematically with definite targets and that it is important to have an attitude not to neglect phenomena that are different from the common sense at the time

  4. Nano-structure formation of Fe-Pt perpendicular magnetic recording media co-deposited with MgO, Al2O3 and SiO2 additives

    International Nuclear Information System (INIS)

    Safran, G.; Suzuki, T.; Ouchi, K.; Barna, P.B.; Radnoczi, G.

    2006-01-01

    Perpendicular magnetic recording media samples were prepared by sputter deposition on sapphire with a layer sequence of MgO seed-layer/Cr under-layer/FeSi soft magnetic under-layer/MgO intermediate layer/FePt-oxide recording layer. The effects of MgO, Al 2 O 3 and SiO 2 additives on the morphology and orientation of the FePt layer were investigated by transmission electron microscopy. The samples exhibited (001) orientation of the L1 FePt phase with the mutual orientations of sapphire substrate//MgO(100)[001]//Cr(100)[11-bar0]//FeSi(100)[11-bar0]//MgO(100) [001]//FePt(001)[100]. The morphology of the FePt films varied due to the co-deposited oxides: The FePt layers were continuous and segmented by stacking faults aligned at 54 o to the surface. Films with SiO 2 addition, beside the oriented columnar FePt grains, exhibited a fraction of misoriented crystallites due to random repeated nucleation. Al 2 O 3 addition resulted in a layered structure, i.e. an initial continuous epitaxial FePt layer covered by a secondary layer of FePt-Al 2 O 3 composite. Both components (FePt and MgO) of the MgO-added samples were grown epitaxially on the MgO intermediate layer, so that a nano-composite of intercalated (001) FePt and (001) MgO was formed. The revealed microstructures and formation mechanisms may facilitate the improvement of the structural and magnetic properties of the FePt-oxide composite perpendicular magnetic recording media

  5. Design of highly oriented (HOR) media for extremely high density recording

    International Nuclear Information System (INIS)

    Hee, C.H.; Wang, J.P.; Chong, T.C.; Low, T.S.

    2001-01-01

    The magnetic properties and recording performance of highly oriented (HOR) longitudinal media are systematically studied via micromagnetic simulation. It was found that highly oriented longitudinal media could be achieved by controlling the anisotropy axes distribution. The effect of anisotropy constant, saturated magnetization and exchange coupling constants on the hysteresis loops are presented. It was further found that highly oriented media show an ultra-low transition noise. Another interesting observation made was that increasing M s for the HOR media decreases the coercivity, which suggests practical usage of this media with current head field. A 500 Gbit/in 2 recording media is simulated to support the application of the highly oriented longitudinal media for ultra high density recording

  6. Quantitative transmission electron microscopy analysis of multi-variant grains in present L10-FePt based heat assisted magnetic recording media

    International Nuclear Information System (INIS)

    Ho, Hoan; Zhu, Jingxi; Kulovits, Andreas; Laughlin, David E.; Zhu, Jian-Gang

    2014-01-01

    We present a study on atomic ordering within individual grains in granular L1 0 -FePt thin films using transmission electron microscopy techniques. The film, used as a medium for heat assisted magnetic recording, consists of a single layer of FePt grains separated by non-magnetic grain boundaries and is grown on an MgO underlayer. Using convergent-beam techniques, diffraction patterns of individual grains are obtained for a large number of crystallites. The study found that although the majority of grains are ordered in the perpendicular direction, more than 15% of them are multi-variant, or of in-plane c-axis orientation, or disordered fcc. It was also found that these multi-variant and in-plane grains have always grown across MgO grain boundaries separating two or more MgO grains of the underlayer. The in-plane ordered portion within a multi-variant L1 0 -FePt grain always lacks atomic coherence with the MgO directly underneath it, whereas, the perpendicularly ordered portion is always coherent with the underlying MgO grain. Since the existence of multi-variant and in-plane ordered grains are severely detrimental to high density data storage capability, the understanding of their formation mechanism obtained here should make a significant impact on the future development of hard disk drive technology

  7. EB curable wetting resins for magnetic media coatings

    International Nuclear Information System (INIS)

    Laskin, L.; Ansel, R.E.; Murray, K.P.; Schmid, S.R.

    1984-01-01

    The magnetic media industry is studying means to improve the recording density, durability, product uniformity and production efficiency and to reduce wetting agent migration in the magnetic film. The use of electron beam curable resin binders for magnetic coatings is one of the approaches being studied for this. This paper compares the wetting efficiencies of several electron beam curable systems with a conventional resin and a conventional wetting agent. In this study it has been demonstrated that EB resins can be designed to effect proper magnetic pigment dispersion

  8. Magnetic resonance perfusion imaging without contrast media

    International Nuclear Information System (INIS)

    Martirosian, Petros; Graf, Hansjoerg; Schick, Fritz; Boss, Andreas; Schraml, Christina; Schwenzer, Nina F.; Claussen, Claus D.

    2010-01-01

    Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs. (orig.)

  9. Making magnetic recording commercial: 1920-1955

    Science.gov (United States)

    Clark, Mark H.

    1999-03-01

    Although magnetic recording had been invented in 1898, it was not until the late 1920s that the technology was successfully marketed to the public. Firms in Germany, the United Kingdom, and the United States developed and sold magnetic recorders for specialized markets in broadcasting and telephone systems through the 1930s. The demands of World War II considerably expanded the use of magnetic recording, and with the end of the war, firms in the United States sought to bring magnetic recording to home and professional music recording. Using a combination of captured German technology and American wartime research, American companies such as Ampex, Magnecord, 3M, the Brush Development Company, and others created a vast new industry. By the mid-1950s, magnetic recording was firmly established as a method for recording both sound and data.

  10. 26 CFR 301.6011-3 - Required use of magnetic media for partnership returns.

    Science.gov (United States)

    2010-04-01

    ... prescribed by the Commissioner. (c) Failure to file. If a partnership fails to file a partnership return on... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Required use of magnetic media for partnership... Returns and Records § 301.6011-3 Required use of magnetic media for partnership returns. (a) Partnership...

  11. Magnetic characterisation of longitudinal thin film media

    International Nuclear Information System (INIS)

    Dova, P.

    1998-09-01

    Magnetic characterisation techniques, as applied to longitudinal thin film media, have been investigated. These included the study of the differentials of the remanence curves, the delta-M plot and the examination of the critical volumes. Several thin film structures, which are currently used or are being considered for future media applications, have been examined using these techniques. Most of the films were Co-alloys with the exception of a set of Barium ferrite films. Both monolayer and multilayer structures were studied. It was found that the study of activation volumes provides a better insight into the reversal mechanisms of magnetic media, especially in the case of complex structures such as multilayer films and films with bicrystal microstructure. Furthermore, an evaluation study of different methods of determining critical volumes showed that the method using time dependence measurements and the micromagnetic approach is the most appropriate. The magnetic characteristics of the thin film media under investigation were correlated with their microstructure and, where possible, with their noise performance. Magnetic force microscopy was also used for acquiring quasi-domain images in the ac-demagnetised state. It was found that in all Co-alloy films the dominant intergranular coupling is magnetising in nature, the level of which is governed by the Cr content in the magnetic layer. In the case of laminated media it was found that when non-magnetic spacers are used, the nature of the interlayer coupling depends on the spacer thickness. In double layer structures with no spacer, the top layer replicates the crystallographic texture of the bottom layer, and the overall film properties are a combination of the two layers. In bicrystal films the coupling is determined by the Cr segregation in the grain boundaries. Furthermore, the presence of stacking faults in bicrystal films deteriorates their thermal stability, but can be prevented by improving the epitaxial

  12. Nuclear signals in magnetically ordered media

    International Nuclear Information System (INIS)

    Ignatchenko, V.A.; Tsifrinovich, V.I.

    1993-01-01

    The book contains a review of theoretical and experimental investigations in the field of nuclear magnetism in magnetically ordered media. The semiclassical theory of nuclear spins motion is developed that takes into consideration three main features of magnetically ordered media: Suhl-Nakamura interaction, quadrupole interaction and microscopic inhomogeneity of nuclear frequencies. The detailed classification of nuclear spin echo signals is given for standard conditions of experiments, when the Suhl-Nakamura interaction is small in comparison with the NMR line width. The extremal states of the electron - nuclear magnetic system are described in detail: the coexistence of NMR and FMR, nuclear ferromagnetism and NMR at fast remagnetization of a ferromagnet. 157 refs., 20 figs

  13. Magnetic Force Microscopy Observation of Perpendicular Recording Head Remanence

    Science.gov (United States)

    Dilekrojanavuti, P.; Saengkaew, K.; Cheowanish, I.; Damrongsak, B.

    2017-09-01

    In this work, magnetic force microscopy (MFM) was utilized to observe the magnetic write head remanence, which is the remaining out-of-plane magnetic field on magnetic write heads after a write current is turned off. This remnant field can write unwanted tracks or erase written tracks on a magnetic media. The write head remanence can also occur from device and slider fabrication, either by applying current to the write coil during the inspection or biasing the external magnetic field to magnetic recording heads. This remanence can attract magnetic nanoparticles, which is suspended in cleaning water or surrounding air, and cause device contamination. MFM images were used to examine locations of the remnant field on the surface of magnetic recording heads. Experimental results revealed that the remanence occurred mostly on the shield and is dependent on the initial direction of magnetic moments. In addition, we demonstrated a potential use of MFM imaging to investigate effects of different etching gases on the head remanence.

  14. Effect of soft underlayer magnetic anisotropy on perpendicular recording process

    International Nuclear Information System (INIS)

    Lim, C.K.; Kim, E.S.; Yoon, S.Y.; Kong, S.H.; Lee, H.S.; Oh, H.S.; Kim, Y.S.

    2007-01-01

    The presence of the soft magnetic underlayer (SUL) in perpendicular magnetic recording (PMR) media is essential for the application. It is commonly understood that the SUL provides the return flux path and enhances the writing field by enhancing the recording field from the write pole. However, SUL increases the magnetic noise during the read back process due to magnetic domain walls in the SUL. Hence, it is common to grow SUL with large uniaxial or unidirectional magnetic anisotropy field (H k ) to reduce domain wall noise. In this paper, we explore the effect of increasing SUL H k on the recording process. We studied this effect by using the finite element micromagnetic simulation. Our simulation results show that the contribution of SUL to the writing field amplitude is reduced with increasing H k . This reduction in magnetic field from high H k SUL actually improves the recording performance due to the better field gradient at SUL. The simulation results are qualitatively consistent with the actual experimental data obtained from the Guzik measurement

  15. Investigation of Condensed Media in Weak Fields by the Method of Nuclear Magnetic Resonance

    Science.gov (United States)

    Davydov, V. V.; Myazin, N. S.; Dudkin, V. I.; Velichko, E. N.

    2018-05-01

    A compact design of a rapid-response nuclear magnetic spectrometer for investigation of condensed media in weak fields is reported. As a result of investigation of different condensed media, special features of recording a nuclear magnetic resonance (NMR) signal in a weak magnetic field from a small volume of the medium under study are established. For the first time the NMR absorption spectra of condensed media in a weak field are collected. Based on the results of experimental studies, the potential of using a compact NMR-spectrometer for condensed media monitoring in a rapid response mode is determined.

  16. Perpendicular magnetic recording-Its development and realization

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, Shun-ichi, E-mail: iwasaki@tohtech.ac.jp [Tohoku Institute of Technology, 35-1 Yagiyamakasumi-cho, Taihaku-ku, Sendai 982-8577 (Japan)

    2012-02-15

    Development of perpendicular magnetic recording is summarized along with learning from the research study. The early stage of perpendicular recording was conducted with the research philosophy of complementarity between perpendicular and horizontal recordings. Although present production of the perpendicular recording HDDs exceeds 600 million per year, development of perpendicular recording experienced the valley of death in the 1990s. The difficult period was overcome by the collaboration system of industrial and academic communities. The research on perpendicular recording brought about development of new research model as well as the historical view of the development of technology and innovation. The huge influence of perpendicular recording on society also taught us the relationship between science and technology with culture and civilization. - Research Highlights: > Discovery of circular magnetization led to idea of perpendicular recording. > SPT head and Co-Cr media were realized for practical perpendicular recording. > The complementarity between perpendicular and in-plane recording helped progress. > Death valley of research has been overcome by cooperation with potent companies. > Present mass production of HDDs is making a new civilization of the society.

  17. Magnetization behavior of nanomagnets for patterned media application

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, S.; Kikuchi, N.; Kato, T.; Kitakami, O. [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Mitsuzuka, K.; Shimatsu, T.; Muraoka, H.; Aoi, H. [Research Institute of Electrical Communication, Tohoku University, Sendai 980-8577 (Japan); Lodder, J.C. [Information Storage Group, MESA, University of Twente, Enschede 7500 AE (Netherlands)], E-mail: j.c.lodder@el.utwente.nl

    2008-11-15

    Bit patterned media (BPM) which utilize each magnetic nanostructured dot as one recorded bit has attracted much interest as a promising candidate for future high-density magnetic recording. In this study, the magnetization reversal behaviors of nanostructured L1{sub 0}-FePt, Co/Pt multilayer (ML), and CoPt/Ru dots are investigated. For Co/Pt and CoPt/Ru nanodots, the bi-stable state is maintained in a very wide size range up to several hundred nm, and the magnetization reversal is dominated by the nucleation of a small reversed nucleus with the dimension of domain wall width. On the other hand, the critical size for the bi-stability of L1{sub 0}-FePt is about 60 nm, and its magnetization reversal proceeds via domain wall displacement even for such a small dot size. These reversal behaviors, depending on the magnetic materials, might be attributed to the difference in structural inhomogeneity, such as defects. In addition to the magnetic properties, the structural uniformity of the material could be crucial for the BPM application.

  18. Micromagnetic modeling for heat-assisted magnetic recording

    International Nuclear Information System (INIS)

    Li Zhenghua; Wei Dan; Wei Fulin

    2008-01-01

    Heat-assisted magnetic recording (HAMR) is one of the candidate systems beyond the perpendicular recording technology. Here, a micromagnetic model and a heat transfer model are introduced to study the heating and cooling processes in the HAMR media; then, by integration of the SPT head and the laser heating source, the recording performance is simulated and investigated on a single track at an area density of 1 Tb/in 2 . In the HAMR system, the temperature in the medium under the laser wave guide is increased by heating, and decreased by air bearing and heat conduction when the write process really occurred. The target of this study is to find the proper design of the head-laser assembly for optimum recording. It is found that the proper distance between the laser wave guide and the head's main pole rear/front edge is only 41.4/1.4 nm for optimum recording performance

  19. Recording voiceover the spoken word in media

    CERN Document Server

    Blakemore, Tom

    2015-01-01

    The only book on the market to specifically address its audience, Recording Voiceover is the comprehensive guide for engineers looking to understand the aspects of capturing the spoken word.Discussing all phases of the recording session, Recording Voiceover addresses everything from microphone recommendations for voice recording to pre-production considerations, including setting up the studio, working with and directing the voice talent, and strategies for reducing or eliminating distracting noise elements found in human speech.Recording Voiceover features in-depth, specific recommendations f

  20. Antiferromagnetic iridium-manganese intermediate layers for perpendicular recording media (invited)

    Science.gov (United States)

    Srinivasan, Kumar; Piramanayagam, S. N.; Sbiaa, Rachid; Kay, Yew Seng; Tan, Hang Khume; Wong, Seng Kai

    2009-04-01

    Current generation of cobalt-oxide-based perpendicular magnetic recording media uses single or dual ruthenium intermediate layers in order to grow crystallographically textured, and magnetically isolated granular media. In this work, the potential advantages of an antiferromagnetic iridium-manganese intermediate layer directly under the recording layer are highlighted. Owing to its close lattice matching with hexagonal cobalt, iridium-manganese which has the L12, or AuCu3-type crystal structure, can support the heteroepitaxial growth of the cobalt-based recording layer. In one of the media schemes described here, (111) textured iridium-manganese thin film was grown on 7.5 nm thick ruthenium layer. On the iridium-manganese as segregation layer, the Co-oxide-based magnetic recording layer showed perpendicular texture with Δθ50 below 4°, coercivity of over 4000 Oe alongside magnetic exchange decoupling, average grain sizes of 6 nm with distributions under 14%, and improved thermal stability. Measurements of the anisotropy constant did not show any significant change and even an IrMn capping layer was observed to improve the thermal stability. The possible mechanisms through which the IrMn layer could affect the thermal stability are hypothesized. The initial layers of the magnetic recording layer on IrMn segregation layers also showed exchange-decoupled and segregated grains, which is unlike that observed on Ru segregation layers. In a second media scheme, (111) textured iridium-manganese thin film was grown on a crystalline soft magnetic underlayer belonging on top of amorphous soft underlayers. In this scheme, partial pinning of the soft underlayer due to exchange-bias interaction with the IrMn layer was observed. This scheme offers the possibility to reduce the intermediate layer thickness, thus improve media writability, and with further optimization, could potentially facilitate the approach toward 1 Tbits/in.2.

  1. Effect of recording condition on the diffraction efficiency of magnetic hologram with magnetic garnet films

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Yuichi, E-mail: nakamura@ee.tut.ac.jp; Takagi, Hiroyuki; Lim, Pang Boey; Inoue, Mitsuteru [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, 1-1 Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2014-09-14

    A holographic memory has been attracting attention as recording media with high recording density and high data transfer rate. We have studied the magnetic garnets as a rewritable and long life media for magnetic holography. However, since the signal intensity of reconstructed image was relatively low, the effects of recording conditions on the diffraction efficiency of magnetic hologram were investigated with experiments and the numerical simulation using COMSOL multi-physics. The diffraction efficiency tends to decrease as increasing the spatial frequency, and the use of short pulse laser with the pulse width of 50 ps was found to be effective to achieve high diffraction efficiency. This suggests that the formation of clear magnetic fringe similar to interference pattern can be obtained by the use of short pulse laser since undesirable heat diffusion during radiation does not occur. On the other hand, the diffraction efficiency increased as increasing the film thickness up to 3.1 μm but was saturated in the garnet film thicker than 3.1 μm in the case of spatial frequency of 1500 line pair/mm. The numerical simulation showed that the effective depth of magnetic fringe was limited about 1.8 μm irrespective of the garnet film thickness because the fringes were connected by thermal diffusion near the surface of the film, and the effective depth is limited due to this connection of the magnetic fringe. Avoiding this fringe connection, much higher diffraction efficiency will be achieved.

  2. Influence of inhomogeneous coercivities on media noise in granular perpendicular media investigated by using magnetic force microscopy

    International Nuclear Information System (INIS)

    Bai, J.; Takahoshi, H.; Ito, H.; Rheem, Y.W.; Saito, H.; Ishio, S.

    2004-01-01

    We investigated the influence of the inhomogeneous coercivities on the media noise in a CoPtCr-SiO 2 granular perpendicular magnetic recording medium via ex situ and in situ magnetic force microscopy (MFM) techniques. The ex situ MFM analyses exhibited that transition zigzags contributed to strong magnetic clusters in noise images, and thus resulted in dominant component of the media noise. According to the in situ MFM measurements, it was suggested that an amount of magnetic grains inside a microscopic area reversed like one magnetic ''particle because of strong inter-grain exchange coupling, and that these microscopic areas showed their local magnetic switching behaviors. A mathematic transformation was used to obtain approximately the magnetization distribution in recording layer. And the individual microscopic areas inside recorded bits were compared quasi-quantitatively with those leading large transition zigzags in magnetization switching behaviors. It was indicated that the inhomogeneous coercivities is one of crucial reasons of the medium noise in the perpendicular magnetic recording

  3. Quantum-dot based nanothermometry in optical plasmonic recording media

    International Nuclear Information System (INIS)

    Maestro, Laura Martinez; Zhang, Qiming; Li, Xiangping; Gu, Min; Jaque, Daniel

    2014-01-01

    We report on the direct experimental determination of the temperature increment caused by laser irradiation in a optical recording media constituted by a polymeric film in which gold nanorods have been incorporated. The incorporation of CdSe quantum dots in the recording media allowed for single beam thermal reading of the on-focus temperature from a simple analysis of the two-photon excited fluorescence of quantum dots. Experimental results have been compared with numerical simulations revealing an excellent agreement and opening a promising avenue for further understanding and optimization of optical writing processes and media

  4. Fast optical recording media based on semiconductor nanostructures for image recording and processing

    International Nuclear Information System (INIS)

    Kasherininov, P. G.; Tomasov, A. A.

    2008-01-01

    Fast optical recording media based on semiconductor nanostructures (CdTe, GaAs) for image recording and processing with a speed to 10 6 cycle/s (which exceeds the speed of known recording media based on metal-insulator-semiconductor-(liquid crystal) (MIS-LC) structures by two to three orders of magnitude), a photosensitivity of 10 -2 V/cm 2 , and a spatial resolution of 5-10 (line pairs)/mm are developed. Operating principles of nanostructures as fast optical recording media and methods for reading images recorded in such media are described. Fast optical processors for recording images in incoherent light based on CdTe crystal nanostructures are implemented. The possibility of their application to fabricate image correlators is shown.

  5. Quaternary magnetic excursions recorded in marine sediments.

    Science.gov (United States)

    Channell, J. E. T.

    2017-12-01

    This year is the golden (50th) anniversary of the first documentation of a magnetic excursion, the Laschamp excursion in volcanics from the Chaine des Puys (Bonhommet and Babkine, 1967). The first recording of an excursion in sediments was from the Blake Outer Ridge (Smith and Foster, 1969). Magnetic excursions are directional aberrations of the geomagnetic field apparently involving short-lived reversal of the main dipole field. They have durations of a few kyrs, and are therefore rarely recorded in sediments with mean sedimentation rates Palma), and 670 ka (Osaka Bay), implying at least 11 excursions in the Brunhes Chron. For the Matuyama Chron, excursions have been recorded in marine sediments at 868 ka (Kamikatsura?), 932 ka (Santa Rosa), 1051 ka (Intra-Jaramillo), 1115 ka (Punaruu), 1255 ka (Bjorn), 1476 ka (Gardar), 1580 ka (Gilsa), and 2737 ka (Porcupine). Excursions coincide with minima in relative paleointensity (RPI) records. Ages are from correlation of excursion records to oxygen isotope records in the same cores, and ice-volume calibration of the oxygen isotope template. The marine sediment record of excursions, combined with independent documentation of excursions in lavas with Ar/Ar age control, is progressively strengthening our knowledge of the excursion inventory in the Quaternary, and enhancing the importance of excursions and RPI in Quaternary stratigraphy.

  6. Read/write properties of oriented longitudinal recording media

    International Nuclear Information System (INIS)

    Uesaka, Y.; Nakatani, Y.; Hayashi, N.; Fukushima, H.

    2001-01-01

    The effect of orientation on the maximum recording density including the thermal stability effect was investigated using computer simulation. The necessary head current for a highly oriented medium is at most 10% larger than that for a 2D random medium. A recording density larger than 300 Gb/in 2 can be achieved with highly oriented media with 30 nm flying height

  7. Radiation scanning system for data recording media

    International Nuclear Information System (INIS)

    Gucza, E.

    1975-01-01

    The scanner of an encoded record support operates by the reflection principle. The record support has tracks brocken down into individual fields which are assigned light-dark markers for encoding purposes.The support consists of a light, non-transparent card which can be pulled over a slot by a guide attached to the scanner. The slot is arranged at an oblique angle relative to the card and emits radiation, for instance, light. This radiation is reflected by the tracks, the empty fields reflecting more radiation than the blackend ones, and then after having been transformed into signals, impinges upon phototransistors through openings. The number of openings corresponds to the number of tracks. The light can be made diffuse prior to exposure of the card by means of a red transparent plastic foil. (DG/RF) [de

  8. Physical principles of microwave assisted magnetic recording

    International Nuclear Information System (INIS)

    Rivkin, Kirill; Benakli, Mourad; Yin, Huaqing; Tabat, Ned

    2014-01-01

    While the basic physics of Microwave Assisted Magnetization Reversal (MAMR) phenomenon is well established both theoretically and experimentally, its application in a practical magnetic recording environment was so far studied primarily with the help of micromagnetic recording models. In this work, we instead attempt to use analytical formulation and simple numerical models to understand the main challenges as well as benefits that are associated with such a system. It appears that the main difference between the previously introduced theory [G. Bertotti et al., Phys. Rev. Lett. 86, 724 (2001); K. Rivkin et al., Appl. Phys. Lett. 92, 153104 (2008); S. Okamoto et al., J. Appl. Phys. 107, 123914 (2010).] and recording environment is that both the RF and DC magnetic fields are applied at a substantial angle to the anisotropy axis. While the associated symmetry breaking prevents one from describing the reversal process explicitly, it is possible to approximate the solutions well enough to satisfactorily match numerical models both in the case of wire and Spin Torque Oscillator generated RF fields. This approach allows for physical explanation of various effects associated with MAMR such as high gradient of writeable anisotropy and reduction of track width, and offers a clear guidance regarding future optimization of MAMR recording.

  9. Physical principles of microwave assisted magnetic recording

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, Kirill; Benakli, Mourad; Yin, Huaqing [Seagate Technology, Edina, Minnesota 55435 (United States); Tabat, Ned [Semaphore Scientific Inc., Chanhassen, Minnesota 55317 (United States)

    2014-06-07

    While the basic physics of Microwave Assisted Magnetization Reversal (MAMR) phenomenon is well established both theoretically and experimentally, its application in a practical magnetic recording environment was so far studied primarily with the help of micromagnetic recording models. In this work, we instead attempt to use analytical formulation and simple numerical models to understand the main challenges as well as benefits that are associated with such a system. It appears that the main difference between the previously introduced theory [G. Bertotti et al., Phys. Rev. Lett. 86, 724 (2001); K. Rivkin et al., Appl. Phys. Lett. 92, 153104 (2008); S. Okamoto et al., J. Appl. Phys. 107, 123914 (2010).] and recording environment is that both the RF and DC magnetic fields are applied at a substantial angle to the anisotropy axis. While the associated symmetry breaking prevents one from describing the reversal process explicitly, it is possible to approximate the solutions well enough to satisfactorily match numerical models both in the case of wire and Spin Torque Oscillator generated RF fields. This approach allows for physical explanation of various effects associated with MAMR such as high gradient of writeable anisotropy and reduction of track width, and offers a clear guidance regarding future optimization of MAMR recording.

  10. Thermal fluctuations in perpendicular recording media: New methodology for estimation of activation moment

    International Nuclear Information System (INIS)

    Mamiya, H; Oba, Y; Ohnuma, M; Hagiya, H; Oku, T; Suzuki, J; Yokoyama, M; Nishihara, Y; Katayama, T; Awano, H; Koda, T

    2011-01-01

    In nanoparticulate films with perpendicular magnetic anisotropy, a large demagnetizing field almost compensates for the experimentally designed change in the magnetic field applied parallel to the film normal. We propose a new method based on field-cycling to eliminate the uncertainty in the demagnetizing response from the analysis of the activation volume of the reversal or magnetic activation moment in such films. In this method, the applied field induced variation in the magnetic relaxation rate is measured before the effect of the demagnetizing field becomes dominant. We also discuss an analogical thermal-cycling method to clarify the temperature dependence of the barrier height for magnetization reversal in a magnetic field. We apply these methods to a Co 74 Pt 16 Cr 10 -SiO 2 nanoparticulate film as an example. The results demonstrate that these methods are useful for studying thermal fluctuations in perpendicular recording media.

  11. Magnetic Thin Films for Perpendicular Magnetic Recording Systems

    Science.gov (United States)

    Sugiyama, Atsushi; Hachisu, Takuma; Osaka, Tetsuya

    In the advanced information society of today, information storage technology, which helps to store a mass of electronic data and offers high-speed random access to the data, is indispensable. Against this background, hard disk drives (HDD), which are magnetic recording devices, have gained in importance because of their advantages in capacity, speed, reliability, and production cost. These days, the uses of HDD extend not only to personal computers and network servers but also to consumer electronics products such as personal video recorders, portable music players, car navigation systems, video games, video cameras, and personal digital assistances.

  12. Magnetization process of heat assisted magnetic recording by micro-magnetic simulation

    International Nuclear Information System (INIS)

    Shiiki, Kazuo; Motojima, Hisanori

    2010-01-01

    Magnetization reversal in a uniform magnetic field and one bit recording process by a thin film head in the heat assisted magnetic recording system of TbFeCo medium are studied by using the micro-magnetic simulation and the heat equation. The Landau-Lifsitz-Gilbert equation is solved for magnetic parameters at temperatures as the time goes by. It is found that magnetization proceeds as a progressive wave, although this behaviour may not limit the recording speed. The recording bit is expanded by the thermal fluctuation. The expansion can be suppressed as the medium thickness increases, because the thermal fluctuation is small in the thick medium. So the control of the medium thickness is important very much to achieve a high-density heat-assisted recording.

  13. Measurement of magnetic property of FePt granular media at near Curie temperature

    International Nuclear Information System (INIS)

    Yang, H.Z.; Chen, Y.J.; Leong, S.H.; An, C.W.; Ye, K.D.; Hu, J.F.

    2017-01-01

    The characterization of the magnetic switching behavior of heat assisted magnetic recording (HAMR) media at near Curie temperature (T_c) is important for high density recording. In this study, we measured the magnetic property of FePt granular media (with room temperature coercivity ~25 kOe) at near T_c with a home built HAMR testing instrument. The local area of HAMR media is heated to near T_c by a flat-top optical heating beam. The magnetic property in the heated area was in-situ measured by a magneto-optic Kerr effect (MOKE) testing beam. The switching field distribution (SFD) and coercive field (H_c) of the FePt granular media and their dependence on the optical heating power at near T_c were studied. We measured the DC demagnetization (DCD) signal with pulsed laser heating at different optical powers. We also measured the T_c distribution of the media by measuring the AC magnetic signal as a function of optical heating power. In a summary, we studied the SFD, H_c of the HAMR media at near T_c in a static manner. The present methodology will facilitate the HAMR media testing. - Highlights: • A flat-top optical beam homogeneously heats up HAMR media to near T_c. • When H_c of media drops to 5 kOe with optical heating, SFD is measured to be 0.6. • H_c, SFD, M_s of HAMR media at near T_c are measured with the methodology.

  14. Measurement of magnetic property of FePt granular media at near Curie temperature

    Energy Technology Data Exchange (ETDEWEB)

    Yang, H.Z., E-mail: YANG_Hongzhi@dsi.a-star.edu.sg; Chen, Y.J.; Leong, S.H.; An, C.W.; Ye, K.D.; Hu, J.F.

    2017-02-01

    The characterization of the magnetic switching behavior of heat assisted magnetic recording (HAMR) media at near Curie temperature (T{sub c}) is important for high density recording. In this study, we measured the magnetic property of FePt granular media (with room temperature coercivity ~25 kOe) at near T{sub c} with a home built HAMR testing instrument. The local area of HAMR media is heated to near T{sub c} by a flat-top optical heating beam. The magnetic property in the heated area was in-situ measured by a magneto-optic Kerr effect (MOKE) testing beam. The switching field distribution (SFD) and coercive field (H{sub c}) of the FePt granular media and their dependence on the optical heating power at near T{sub c} were studied. We measured the DC demagnetization (DCD) signal with pulsed laser heating at different optical powers. We also measured the T{sub c} distribution of the media by measuring the AC magnetic signal as a function of optical heating power. In a summary, we studied the SFD, H{sub c} of the HAMR media at near T{sub c} in a static manner. The present methodology will facilitate the HAMR media testing. - Highlights: • A flat-top optical beam homogeneously heats up HAMR media to near T{sub c}. • When H{sub c} of media drops to 5 kOe with optical heating, SFD is measured to be 0.6. • H{sub c}, SFD, M{sub s} of HAMR media at near T{sub c} are measured with the methodology.

  15. Recording-media-related morphology and magnetic properties of crystalline CoPt{sub 3} and CoPt{sub 3}-Au core-shell nanoparticles synthesized via reverse microemulsion

    Energy Technology Data Exchange (ETDEWEB)

    Bahmanrokh, Ghazaleh, E-mail: ghazalehbahmanrokh@yahoo.com; Hashim, Mansor; Matori, Khamirul Amin; Kanagesan, Samikannu; Sabbaghizadeh, Rahim; Ezzad Shafie, Mohd Shamsul [Materials Synthesis and Characterization Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Navasery, Manizheh; Soltani, Nayereh [Department of Physics, Faculty of Science, Universiti Putra Malaysia, 43400 UPM, Serdang, Selangor (Malaysia); Vaziri, Parisa [Department of Medical Physics and Biomedical Engineering, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2014-09-07

    A comparative experimental study of the magnetic properties of CoPt{sub 3} and CoPt{sub 3}/Au nanoparticles as well as a detailed study of the structural properties of the samples by X-ray diffraction, Transmission electron microscopy, and vibrating sample magnetometer is presented in this work. In addition, the effect of particle size on the structure and magnetic properties of nanoparticles prepared by microemulsion is studied. The correlation between particle size, crystallinity, and magnetization was studied as well. CoPt nanoparticles have been studied intensively over the last decade because of their increased magnetic anisotropy in the ordered phase that can be interesting for high density magnetic recording. A significant high coercivity for as-prepared CoPt{sub 3} and CoPt{sub 3}-Au nanoparticles was obtained at room temperature and enhanced after annealing. The focused aim of our study is to obtain high coercivity at room temperature that follows the Curie-Weiss law. This indicates an interacting system in which the nanoparticles behave like single domain ferromagnetic materials in the particle size range of 8 to 35 nm. In addition, the interaction increases by cooling the samples to low temperature around 15 K. Temperature dependence 1/M graph was obtained to investigate the behavior of nanoparticles at low temperature and shows the best fit with Curie-Weis mode.

  16. Detection of extremely high bit density signals with a narrow track width GMR head in double layered perpendicular recording media

    International Nuclear Information System (INIS)

    Kiya, T.; Honda, N.; Ariake, J.; Ouchi, K.; Iwasaki, S.

    2001-01-01

    Recording resolution, medium noise and thermal stability have been investigated for double layered perpendicular magnetic recording media. The recording performance was improved by introducing a stacked intermediate layer between a soft magnetic backlayer and a storage layer due to increased crystal orientation with a small magnetic domain size and suppressed initial growing layer of the storage layer. The reproduced output at an extremely high linear density of 950 kFRPI was detected by using a contact-type CF-SPT head for write and a GMR head with a narrow read track width of 0.4 μm

  17. Intermediate layer thickness dependence on switching field distribution in perpendicular recording media

    International Nuclear Information System (INIS)

    Sbiaa, R.; Gandhi, R.; Srinivasan, K.; Piramanayagam, S.N.; Seoh, R.M.

    2009-01-01

    The effect of intermediate layer (IL) thickness on crystallographic texture and magnetic properties of CoCrPtSiO 2 granular perpendicular recording media was investigated with switching field distribution (SFD) as the focus. Even though the c-axis orientation of the Co-based recording layer (RL) broadens with the reduction of IL thickness, the SFD becomes narrower. This result demonstrates that the intrinsic SFD is not directly dependent on c-axis orientation of the recording layer but instead dependent on the magnitude of exchange coupling. It is thus possible to have a medium with thin IL and narrow SFD. This is desirable for bit-patterned media (BPM), where highly exchange-coupled grains are required.

  18. Perfluorocyclobutane containing aromatic ether polymers as planarization materials for alternative magnetic media substrates

    Science.gov (United States)

    Perettie, Donald J.; Judy, Jack; Chen, Qixu; Keirstead, Rick

    1994-11-01

    Perfluorocyclobutane aromatic ether polymers (PFCB) are being researched as planarization materials for alternative magnetic media substrates allowing smoother surfaces for lower head flying recording. The results of current work reported herein have shown that PFCB can be used to affect surfaces on canasite with R(sub A)'s less than 2 nm. In addition, magnetic media can be produced of a quality comparative to that obtained on standard NiP-coated Al as well as that produced on regular canasite with equivalent coercivities at about 1500-1600 Oe and squarenesses of 0.8 or better. In addition to the above magnetic properties the recording performance was excellent with signal-to-noise ratios of planarized media 3.5 dB higher than that on regular canasite.

  19. Coding and signal processing for magnetic recording systems

    CERN Document Server

    Vasic, Bane

    2004-01-01

    RECORDING SYSTEMSA BriefHistory of Magnetic Storage, Dean PalmerPhysics of Longitudinal and Perpendicular Recording, Hong Zhou, Tom Roscamp, Roy Gustafson, Eric Boernern, and Roy ChantrellThe Physics of Optical Recording, William A. Challener and Terry W. McDanielHead Design Techniques for Recording Devices, Robert E. RottmayerCOMMUNICATION AND INFORMATION THEORY OF MAGNETIC RECORDING CHANNELSModeling the Recording Channel, Jaekyun MoonSignal and Noise Generation for Magnetic Recording Channel Simulations, Xueshi Yang and Erozan M. KurtasStatistical Analysis of Digital Signals and Systems, Dra

  20. Eddy current effect in soft magnetic backlayer for PMR media

    International Nuclear Information System (INIS)

    Tanaka, T.; Yamamoto, S.; Kurisu, H.; Matsuura, M.

    2005-01-01

    Flux density distributions in the recording layer and soft magnetic backlayer of a perpendicular magnetic recording medium were calculated up to 5 GHz using a three-dimensional finite element method electromagnetic field analysis simulator, where eddy current effects in the high-frequency recording process were considered. It is presented that the flux density distribution in a recording layer hardly depends on the eddy current effect, although flux density distribution in a soft magnetic backlayer changes depending on the recording frequency and resistivity of the soft magnetic backlayer

  1. 26 CFR 301.6011-5 - Required use of magnetic media for corporate income tax returns.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Required use of magnetic media for corporate income tax returns. 301.6011-5 Section 301.6011-5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Information and Returns Returns and Records § 301.6011-5...

  2. Lubricant reflow after laser heating in heat assisted magnetic recording

    Science.gov (United States)

    Wu, Haoyu; Mendez, Alejandro Rodriguez; Xiong, Shaomin; Bogy, David B.

    2015-05-01

    In heat assisted magnetic recording (HAMR) technology for hard disk drives, the media will be heated to about 500 °C during the writing process in order to reduce its magnetic coercivity and thus allow data writing with the magnetic head transducers. The traditional lubricants such as Z-dol and Z-tetraol may not be able to perform in such harsh heating conditions due to evaporation, decomposition and thermal depletion. However, some of the lubricant depletion can be recovered due to reflow after a period of time, which can help to reduce the chance of head disk interface failure. In this study, experiments of lubricant thermal depletion and reflow were performed using a HAMR test stage for a Z-tetraol type lubricant. Various lubricant depletion profiles were generated using different laser heating conditions. The lubricant reflow process after thermal depletion was monitored by use of an optical surface analyzer. In addition, a continuum based lubrication model was developed to simulate the lubricant reflow process. Reasonably good agreement between simulations and experiments was achieved.

  3. Ring head recording on perpendicular media: Output spectra for CoCr and CoCr/NiFe media

    Science.gov (United States)

    Stubbs, D. P.; Whisler, J. W.; Moe, C. D.; Skorjanec, J.

    1985-04-01

    The recording density response for sputtered CoCr (thickness=0.5 μm) and CoCr/NiFe (t=0.25 μm/0.5 μm) as well as evaporated CoNi (t=0.12 μm) and Co surface-doped iron oxide particulate media has been measured by reading and writing with Mn-Zn ferrite heads (gap length=0.375 μm, track width=37 μm) in contact with the media. Measurements to 200 kfc/i (thousand flux changes per inch) show a gap null around 115 kfc/i. The data have been normalized by dividing out the head sensitivity to obtain the value of spacing plus transition width (d+a) for the various media. For the CoCr media this value varied from 0.075-0.088 μm; for CoNi, 0.100 μm, and for the particulate medium, 0.163 μm. In addition, testing with a larger gapped Mn-Zn ferrite head (g=2.43 μm) shows that the head fields are distorted by the soft magnetic underlayer in dual layer CoCr/NiFe samples when the gap length is large compared to the distance to the underlayer.

  4. Dynamics of magnetic nanoparticles in viscoelastic media

    Energy Technology Data Exchange (ETDEWEB)

    Remmer, Hilke, E-mail: h.remmer@tu-bs.de [Institute of Electrical Measurement and Fundamental Electrical Engineering, TU Braunschweig, Braunschweig (Germany); Roeben, Eric; Schmidt, Annette M. [Institute of Physical Chemistry, Universität zu Köln, Köln (Germany); Schilling, Meinhard; Ludwig, Frank [Institute of Electrical Measurement and Fundamental Electrical Engineering, TU Braunschweig, Braunschweig (Germany)

    2017-04-01

    We compare different models for the description of the complex susceptibility of magnetic nanoparticles in an aqueous gelatin solution representing a model system for a Voigt-Kelvin scheme. The analysis of susceptibility spectra with the numerical model by Raikher et al. is compared with the analysis applying a phenomenological, modified Debye model. The fit of the models to the measured data allows one to extract the viscoelastic parameter dynamic viscosity η and shear modulus G. The experimental data were recorded on single-core thermally blocked CoFe{sub 2}O{sub 4} nanoparticles in an aqueous solution with 2.5 wt% gelatin. Whereas the dynamic viscosities obtained by fitting the model – extended by distributions of hydrodynamic diameters and viscosities – agree very well, the derived values for the shear modulus show the same temporal behavior during the gelation process, but vary approximately by a factor of two. To verify the values for viscosity and shear modulus obtained from nanorheology, macrorheological measurements are in progress. - Highlights: • Ac susceptibility spectra of CoFe2O4 nanoparticles in aqueous gelatin solution. • Analysis of spectra with different approaches of Voigt-Kelvin model. • Comparison of modified Debye model with numerical model. • Both models provide similar values for viscoelastic parameters.

  5. Patterned magnetic thin films for ultra high density recording

    NARCIS (Netherlands)

    Haast, M.A.M.

    This thesis describes the results of a research project in the field of high bit-density data-storage media. More specifically, the material aspects of the novel recording technique using patterned media have been studied. The aim of the work was the design, realization and characterization of such

  6. Transition analysis of magnetic recording heads using FDTD

    International Nuclear Information System (INIS)

    Tanabe, Shinji

    2001-01-01

    Transition waveforms of a magnetic recording head have been analyzed using finite difference time domain (FDTD). The distributed inductance and capacitance of the head effect the rising time of the magnetic fields in the recording process. FDTD electromagnetic analysis is easy to combine with SPICE circuit analysis. Using this combined program, a transition analysis of the recording process including a write amplifier has become possible

  7. Transition analysis of magnetic recording heads using FDTD

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Shinji E-mail: tanabe@ele.crl.melco.co.jp

    2001-10-01

    Transition waveforms of a magnetic recording head have been analyzed using finite difference time domain (FDTD). The distributed inductance and capacitance of the head effect the rising time of the magnetic fields in the recording process. FDTD electromagnetic analysis is easy to combine with SPICE circuit analysis. Using this combined program, a transition analysis of the recording process including a write amplifier has become possible.

  8. Magnetic Fields Recorded by Chondrules Formed in Nebular Shocks

    Science.gov (United States)

    Mai, Chuhong; Desch, Steven J.; Boley, Aaron C.; Weiss, Benjamin P.

    2018-04-01

    Recent laboratory efforts have constrained the remanent magnetizations of chondrules and the magnetic field strengths to which the chondrules were exposed as they cooled below their Curie points. An outstanding question is whether the inferred paleofields represent the background magnetic field of the solar nebula or were unique to the chondrule-forming environment. We investigate the amplification of the magnetic field above background values for two proposed chondrule formation mechanisms, large-scale nebular shocks and planetary bow shocks. Behind large-scale shocks, the magnetic field parallel to the shock front is amplified by factors of ∼10–30, regardless of the magnetic diffusivity. Therefore, chondrules melted in these shocks probably recorded an amplified magnetic field. Behind planetary bow shocks, the field amplification is sensitive to the magnetic diffusivity. We compute the gas properties behind a bow shock around a 3000 km radius planetary embryo, with and without atmospheres, using hydrodynamics models. We calculate the ionization state of the hot, shocked gas, including thermionic emission from dust, thermal ionization of gas-phase potassium atoms, and the magnetic diffusivity due to Ohmic dissipation and ambipolar diffusion. We find that the diffusivity is sufficiently large that magnetic fields have already relaxed to background values in the shock downstream where chondrules acquire magnetizations, and that these locations are sufficiently far from the planetary embryos that chondrules should not have recorded a significant putative dynamo field generated on these bodies. We conclude that, if melted in planetary bow shocks, chondrules probably recorded the background nebular field.

  9. Radiation curable polymer blends for magnetic media

    International Nuclear Information System (INIS)

    Santosusso, T.M.

    1985-01-01

    Binder resins in magnetic coating formulations must fulfil a diverse set of requirements. These polymers must have the ability to accept high pigment loadings while maintaining good abrasion resistance, substrate adhesion, inherent lubricity and resistance to temperature and humidity effects. In addition, they must act as grinding aids in the dispersion of the magnetic pigment. In the thermally converted coatings now in use, these requirements are usually met by combining several polymers and crosslinking agents into an optimized blend. This approach is also effective in designing radiation curable binder systems. An overview of the methods employed to achieve such optimized blends will be discussed. (author)

  10. Direct Magnetic Relief Recording Using As40S60: Mn-Se Nanocomposite Multilayer Structures.

    Science.gov (United States)

    Stronski, A; Achimova, E; Paiuk, O; Meshalkin, A; Prisacar, A; Triduh, G; Oleksenko, P; Lytvyn, P

    2017-12-01

    Processes of holographic recording of surface relief structures using As 2 S 3 :Mn-Se multilayer nanostructures as registering media were studied in this paper. Optical properties of As 2 S 3 :Mn, Se layers, and As 2 S 3 :Mn-Se multilayer nanostructures were investigated. Values of optical bandgaps were obtained from Tauc dependencies. Surface relief diffraction gratings were recorded. Direct one-stage formation of surface relief using multilayer nanostructures is considered. For the first time, possibility of direct formation of magnetic relief simultaneous with surface relief formation under optical recording using As 2 S 3 :Mn-Se multilayer nanostructures is shown.

  11. The recording characteristics of particulate double layers with hard-magnetic and soft-magnetic underlayers

    NARCIS (Netherlands)

    Lalbahadoersing, S.; Groenland, J.P.J.; Luitjens, S.B.; Lodder, J.C.

    2002-01-01

    Particulate double-layer tape samples with magnetic underlayers have been investigated by performing magnetic recording measurements and by computer simulation.The presence of soft-magnetic underlayers resulted in decreased signal output and better overwrite behavior. Hard-magnetic underlayers

  12. Microwave-assisted shingled magnetic recording simulations on an exchange-coupled composite medium

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T., E-mail: t-tanaka@ed.kyushu-u.ac.jp [Department of Electronics, Graduate School of Information Science and Electrical Engineering, Kyushu University, Motoota 744, Nishi-ku, Fukuoka 819-0395 (Japan); Kashiwagi, S. [Department of Electronics, Graduate School of Information Science and Electrical Engineering, Kyushu University, Motoota 744, Nishi-ku, Fukuoka 819-0395 (Japan); Kanai, Y. [Department of Information and Electronics Engineering, Niigata Institute of Technology, Fujihashi 1719, Kashiwazaki, Niigata 945-1195 (Japan); Matsuyama, K. [Department of Electronics, Graduate School of Information Science and Electrical Engineering, Kyushu University, Motoota 744, Nishi-ku, Fukuoka 819-0395 (Japan)

    2016-10-15

    The potential of microwave-assisted magnetic recording combined with the shingled recording scheme has been studied by simulating read/write processes on exchange-coupled composite media focusing on recording characteristics in the cross-track direction. Microwave fields enhance writability, especially at the track edge, resulting in lower noise and higher signal-to-noise ratio (SNR), which enables higher track density in the shingled recording scheme. Read/write simulations of microwave-assisted shingled recording achieve 1.4 Mtracks/in. while retaining high SNR. Further increases in SNR and track density will require either a narrower reader or track edge noise reduction. - Highlights: • Signal recording of shingled magnetic recording using an asymmetric single pole type head combined with a microwave assistance was numerically demonstrated. • Writability is improved by microwave fields with a moderate frequency at the track edge of the shielded side, resulting in higher signal-to-noise ratio. • 1.41 Mtpi of track density is feasible for the recording scheme of shingled magnetic recording with microwave assistance.

  13. Microwave-assisted shingled magnetic recording simulations on an exchange-coupled composite medium

    International Nuclear Information System (INIS)

    Tanaka, T.; Kashiwagi, S.; Kanai, Y.; Matsuyama, K.

    2016-01-01

    The potential of microwave-assisted magnetic recording combined with the shingled recording scheme has been studied by simulating read/write processes on exchange-coupled composite media focusing on recording characteristics in the cross-track direction. Microwave fields enhance writability, especially at the track edge, resulting in lower noise and higher signal-to-noise ratio (SNR), which enables higher track density in the shingled recording scheme. Read/write simulations of microwave-assisted shingled recording achieve 1.4 Mtracks/in. while retaining high SNR. Further increases in SNR and track density will require either a narrower reader or track edge noise reduction. - Highlights: • Signal recording of shingled magnetic recording using an asymmetric single pole type head combined with a microwave assistance was numerically demonstrated. • Writability is improved by microwave fields with a moderate frequency at the track edge of the shielded side, resulting in higher signal-to-noise ratio. • 1.41 Mtpi of track density is feasible for the recording scheme of shingled magnetic recording with microwave assistance.

  14. Microbially assisted recording of the Earth's magnetic field in sediment.

    Science.gov (United States)

    Zhao, Xiangyu; Egli, Ramon; Gilder, Stuart A; Müller, Sebastian

    2016-02-11

    Sediments continuously record variations of the Earth's magnetic field and thus provide an important archive for studying the geodynamo. The recording process occurs as magnetic grains partially align with the geomagnetic field during and after sediment deposition, generating a depositional remanent magnetization (DRM) or post-DRM (PDRM). (P)DRM acquisition mechanisms have been investigated for over 50 years, yet many aspects remain unclear. A key issue concerns the controversial role of bioturbation, that is, the mechanical disturbance of sediment by benthic organisms, during PDRM acquisition. A recent theory on bioturbation-driven PDRM appears to solve many inconsistencies between laboratory experiments and palaeomagnetic records, yet it lacks experimental proof. Here we fill this gap by documenting the important role of bioturbation-induced rotational diffusion for (P)DRM acquisition, including the control exerted on the recorded inclination and intensity, as determined by the equilibrium between aligning and perturbing torques acting on magnetic particles.

  15. Electron holography of magnetic field generated by a magnetic recording head.

    Science.gov (United States)

    Goto, Takayuki; Jeong, Jong Seok; Xia, Weixing; Akase, Zentaro; Shindo, Daisuke; Hirata, Kei

    2013-06-01

    The magnetic field generated by a magnetic recording head is evaluated using electron holography. A magnetic recording head, which is connected to an electric current source, is set on the specimen holder of a transmission electron microscope. Reconstructed phase images of the region around the magnetic pole show the change in the magnetic field distribution corresponding to the electric current applied to the coil of the head. A simulation of the magnetic field, which is conducted using the finite element method, reveals good agreement with the experimental observations.

  16. Methodology Investigation Automatic Magnetic Recording Borescope.

    Science.gov (United States)

    1986-01-01

    or other brushless signal coupling devices to the extent possible and feasible to reduce or eliminate the need for slip ring and brush type signal...the inspection head, is used to magnetically couple the necessary energy across the rotary interface. Because there is (1) an appreciable air gap in...were written. (2) As required by the contract, the signal conditioners in the MB employ automatic gain control to compensate for the changes in

  17. Perpendicular Magnetic Anisotropy in FePt Patterned Media Employing a CrV Seed Layer

    Directory of Open Access Journals (Sweden)

    Chun Dong

    2011-01-01

    Full Text Available Abstract A thin FePt film was deposited onto a CrV seed layer at 400°C and showed a high coercivity (~3,400 Oe and high magnetization (900–1,000 emu/cm3 characteristic of L10 phase. However, the magnetic properties of patterned media fabricated from the film stack were degraded due to the Ar-ion bombardment. We employed a deposition-last process, in which FePt film deposited at room temperature underwent lift-off and post-annealing processes, to avoid the exposure of FePt to Ar plasma. A patterned medium with 100-nm nano-columns showed an out-of-plane coercivity fivefold larger than its in-plane counterpart and a remanent magnetization comparable to saturation magnetization in the out-of-plane direction, indicating a high perpendicular anisotropy. These results demonstrate the high perpendicular anisotropy in FePt patterned media using a Cr-based compound seed layer for the first time and suggest that ultra-high-density magnetic recording media can be achieved using this optimized top-down approach.

  18. Short-wavelength magnetic recording new methods and analyses

    CERN Document Server

    Ruigrok, JJM

    2013-01-01

    Short-wavelength magnetic recording presents a series of practical solutions to a wide range of problems in the field of magnetic recording. It features many new and original results, all derived from fundamental principles as a result of up-to-date research.A special section is devoted to the playback process, including the calculations of head efficiency and head impedance, derived from new theorems.Features include:A simple and fast method for measuring efficiency; a simple method for the accurate separation of the read and write behaviour of magnetic heads; a new concept - the bandpass hea

  19. NANO-MULTILAYERS WITH HIGH PERPENDICULAR ANISOTROPY FOR MAGNETIC RECORDING

    Institute of Scientific and Technical Information of China (English)

    T. Yang; B.H. Li; K. Kang; T. Suzuki

    2003-01-01

    (FePt/Ag)n nano-multilayers were deposited on MgO (100) single crystal with laser ablation and then subjected to annealing. FePt L1o grains with (001) texture and thus a large perpendicular magnetic anisotropy constant Ku of the order of 106J/m3 were formed. A thick Ag layer is found to be favorable for decreasing the dispersion of the easy axis for magnetization. The measurement of time decay of magnetization gave rise to a small activation volume of the order of 10-25 m3, showing the promising of being the recording medium for future high density perpendicular recording.

  20. Magnetic characterisation of recording materials: design, instrumentation and experimental methods

    NARCIS (Netherlands)

    Samwel, E.O.

    1995-01-01

    The progress being made in the field of magnetic recording is extremely fast. The need to keep this progress going, leads to new types of recording materials which require advanced measurement systems and measurement procedures. Furthermore, the existing measurement methods need to be reviewed as

  1. Fe-N and (Fe, Ni)-N Fine Powders for Magnetic Recording

    International Nuclear Information System (INIS)

    Chen Ziyu; Li Fashen

    1998-01-01

    Combining Moessbauer spectroscopy with magnetic property measurement, we have studied Fe-N and (Fe, Ni)-N powders for magnetic recording. The typical particles of the core (α-Fe)/shell (γ'-Fe 4 N) structure have been successfully prepared. All the products are stabilized in a multi-organic solution. It has been found that the coercivity can be changed from 300 to 800 Oe by adjusting the shape of the particles. The special saturation magnetization of the particles can be adjusted from 120 to 180emu/g and their chemical stability is improved by substituting nickel for iron in γ'-Fe 4 N. Following experiments for corrosion resistance, it is expected that (Fe, Ni)-N and the core/shell particles will be applied as recording media in the near future

  2. Fe-N and (Fe, Ni)-N Fine Powders for Magnetic Recording

    Energy Technology Data Exchange (ETDEWEB)

    Chen Ziyu; Li Fashen [Lanzhou University, Department of Physics (China)

    1998-12-15

    Combining Moessbauer spectroscopy with magnetic property measurement, we have studied Fe-N and (Fe, Ni)-N powders for magnetic recording. The typical particles of the core ({alpha}-Fe)/shell ({gamma}'-Fe{sub 4}N) structure have been successfully prepared. All the products are stabilized in a multi-organic solution. It has been found that the coercivity can be changed from 300 to 800 Oe by adjusting the shape of the particles. The special saturation magnetization of the particles can be adjusted from 120 to 180emu/g and their chemical stability is improved by substituting nickel for iron in {gamma}'-Fe{sub 4}N. Following experiments for corrosion resistance, it is expected that (Fe, Ni)-N and the core/shell particles will be applied as recording media in the near future.

  3. Methods for characterizing magnetic footprints of perpendicular magnetic recording writer heads

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shaoping, E-mail: shaoping.li@wdc.com; Lin, Ed; George, Zach; Terrill, Dave; Mendez, H.; Santucci, J.; Yie, Derek [Western Digital Corp., 44100 Osgood Road, Fremont, California 94539 (United States)

    2014-05-07

    In this work, the magnetic footprints, along with some of its dynamic features in recording process, of perpendicular magnetic recording writer heads have been characterized by using three different techniques. Those techniques are the spin-stand stationary footprint technique, the spin-stand dynamic footprint technique, and the coherent writing technique combined with magnetic force microscope imaging method. The characteristics of those techniques have been compared to one another. It was found experimentally that the spin-stand stationary method could not precisely catch some peculiar recording dynamics of the write heads in certain conditions. The advantages and disadvantages among all those techniques are also examined and discussed in detail.

  4. Methods for characterizing magnetic footprints of perpendicular magnetic recording writer heads

    International Nuclear Information System (INIS)

    Li, Shaoping; Lin, Ed; George, Zach; Terrill, Dave; Mendez, H.; Santucci, J.; Yie, Derek

    2014-01-01

    In this work, the magnetic footprints, along with some of its dynamic features in recording process, of perpendicular magnetic recording writer heads have been characterized by using three different techniques. Those techniques are the spin-stand stationary footprint technique, the spin-stand dynamic footprint technique, and the coherent writing technique combined with magnetic force microscope imaging method. The characteristics of those techniques have been compared to one another. It was found experimentally that the spin-stand stationary method could not precisely catch some peculiar recording dynamics of the write heads in certain conditions. The advantages and disadvantages among all those techniques are also examined and discussed in detail

  5. Methods for characterizing magnetic footprints of perpendicular magnetic recording writer heads

    Science.gov (United States)

    Li, Shaoping; Lin, Ed; George, Zach; Terrill, Dave; Mendez, H.; Santucci, J.; Yie, Derek

    2014-01-01

    In this work, the magnetic footprints, along with some of its dynamic features in recording process, of perpendicular magnetic recording writer heads have been characterized by using three different techniques. Those techniques are the spin-stand stationary footprint technique, the spin-stand dynamic footprint technique, and the coherent writing technique combined with magnetic force microscope imaging method. The characteristics of those techniques have been compared to one another. It was found experimentally that the spin-stand stationary method could not precisely catch some peculiar recording dynamics of the write heads in certain conditions. The advantages and disadvantages among all those techniques are also examined and discussed in detail. PMID:24753633

  6. Impact of radius and skew angle on areal density in heat assisted magnetic recording hard disk drives

    Science.gov (United States)

    Cordle, Michael; Rea, Chris; Jury, Jason; Rausch, Tim; Hardie, Cal; Gage, Edward; Victora, R. H.

    2018-05-01

    This study aims to investigate the impact that factors such as skew, radius, and transition curvature have on areal density capability in heat-assisted magnetic recording hard disk drives. We explore a "ballistic seek" approach for capturing in-situ scan line images of the magnetization footprint on the recording media, and extract parametric results of recording characteristics such as transition curvature. We take full advantage of the significantly improved cycle time to apply a statistical treatment to relatively large samples of experimental curvature data to evaluate measurement capability. Quantitative analysis of factors that impact transition curvature reveals an asymmetry in the curvature profile that is strongly correlated to skew angle. Another less obvious skew-related effect is an overall decrease in curvature as skew angle increases. Using conventional perpendicular magnetic recording as the reference case, we characterize areal density capability as a function of recording position.

  7. Spinstand demonstration of areal density enhancement using two-dimensional magnetic recording (invited)

    Science.gov (United States)

    Lippman, Thomas; Brockie, Richard; Coker, Jon; Contreras, John; Galbraith, Rick; Garzon, Samir; Hanson, Weldon; Leong, Tom; Marley, Arley; Wood, Roger; Zakai, Rehan; Zolla, Howard; Duquette, Paul; Petrizzi, Joe

    2015-05-01

    Exponential growth of the areal density has driven the magnetic recording industry for almost sixty years. But now areal density growth is slowing down, suggesting that current technologies are reaching their fundamental limit. The next generation of recording technologies, namely, energy-assisted writing and bit-patterned media, remains just over the horizon. Two-Dimensional Magnetic Recording (TDMR) is a promising new approach, enabling continued areal density growth with only modest changes to the heads and recording electronics. We demonstrate a first generation implementation of TDMR by using a dual-element read sensor to improve the recovery of data encoded by a conventional low-density parity-check (LDPC) channel. The signals are combined with a 2D equalizer into a single modified waveform that is decoded by a standard LDPC channel. Our detection hardware can perform simultaneous measurement of the pre- and post-combined error rate information, allowing one set of measurements to assess the absolute areal density capability of the TDMR system as well as the gain over a conventional shingled magnetic recording system with identical components. We discuss areal density measurements using this hardware and demonstrate gains exceeding five percent based on experimental dual reader components.

  8. Spinstand demonstration of areal density enhancement using two-dimensional magnetic recording (invited)

    International Nuclear Information System (INIS)

    Lippman, Thomas; Brockie, Richard; Contreras, John; Garzon, Samir; Leong, Tom; Marley, Arley; Wood, Roger; Zakai, Rehan; Zolla, Howard; Coker, Jon; Galbraith, Rick; Hanson, Weldon; Duquette, Paul; Petrizzi, Joe

    2015-01-01

    Exponential growth of the areal density has driven the magnetic recording industry for almost sixty years. But now areal density growth is slowing down, suggesting that current technologies are reaching their fundamental limit. The next generation of recording technologies, namely, energy-assisted writing and bit-patterned media, remains just over the horizon. Two-Dimensional Magnetic Recording (TDMR) is a promising new approach, enabling continued areal density growth with only modest changes to the heads and recording electronics. We demonstrate a first generation implementation of TDMR by using a dual-element read sensor to improve the recovery of data encoded by a conventional low-density parity-check (LDPC) channel. The signals are combined with a 2D equalizer into a single modified waveform that is decoded by a standard LDPC channel. Our detection hardware can perform simultaneous measurement of the pre- and post-combined error rate information, allowing one set of measurements to assess the absolute areal density capability of the TDMR system as well as the gain over a conventional shingled magnetic recording system with identical components. We discuss areal density measurements using this hardware and demonstrate gains exceeding five percent based on experimental dual reader components

  9. Spinstand demonstration of areal density enhancement using two-dimensional magnetic recording (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Lippman, Thomas, E-mail: Thomas.Lippman@hgst.com; Brockie, Richard; Contreras, John; Garzon, Samir; Leong, Tom; Marley, Arley; Wood, Roger; Zakai, Rehan; Zolla, Howard [HGST, a Western Digital Company, San Jose, California 95119 (United States); Coker, Jon; Galbraith, Rick; Hanson, Weldon [HGST, a Western Digital Company, Rochester, Minnesota 55901 (United States); Duquette, Paul; Petrizzi, Joe [Avago Technologies, San Jose, California 95131 (United States)

    2015-05-07

    Exponential growth of the areal density has driven the magnetic recording industry for almost sixty years. But now areal density growth is slowing down, suggesting that current technologies are reaching their fundamental limit. The next generation of recording technologies, namely, energy-assisted writing and bit-patterned media, remains just over the horizon. Two-Dimensional Magnetic Recording (TDMR) is a promising new approach, enabling continued areal density growth with only modest changes to the heads and recording electronics. We demonstrate a first generation implementation of TDMR by using a dual-element read sensor to improve the recovery of data encoded by a conventional low-density parity-check (LDPC) channel. The signals are combined with a 2D equalizer into a single modified waveform that is decoded by a standard LDPC channel. Our detection hardware can perform simultaneous measurement of the pre- and post-combined error rate information, allowing one set of measurements to assess the absolute areal density capability of the TDMR system as well as the gain over a conventional shingled magnetic recording system with identical components. We discuss areal density measurements using this hardware and demonstrate gains exceeding five percent based on experimental dual reader components.

  10. Lubricant depletion under various laser heating conditions in Heat Assisted Magnetic Recording (HAMR)

    Science.gov (United States)

    Xiong, Shaomin; Wu, Haoyu; Bogy, David

    2014-09-01

    Heat assisted magnetic recording (HAMR) is expected to increase the storage areal density to more than 1 Tb/in2 in hard disk drives (HDDs). In this technology, a laser is used to heat the magnetic media to the Curie point (~400-600 °C) during the writing process. The lubricant on the top of a magnetic disk could evaporate and be depleted under the laser heating. The change of the lubricant can lead to instability of the flying slider and failure of the head-disk interface (HDI). In this study, a HAMR test stage is developed to study the lubricant thermal behavior. Various heating conditions are controlled for the study of the lubricant thermal depletion. The effects of laser heating repetitions and power levels on the lubricant depletion are investigated experimentally. The lubricant reflow behavior is discussed as well.

  11. A method of producing small grain Ru intermediate layers for perpendicular magnetic media

    International Nuclear Information System (INIS)

    Yuan Hua; Qin Yueling; Laughlin, David E.

    2008-01-01

    NiAl + SiO 2 thin films were used as a grain size reducing seedlayer for cobalt alloy granular perpendicular magnetic recording media. The effect of this NiAl + SiO 2 seedlayer on the microstructure and crystalline orientation of Ru intermediate layer has been investigated. By co-sputtering the composite NiAl + SiO 2 seedlayer, the smallest average grain diameter of NiAl was significantly reduced to about 2.5 nm. The grain size of the subsequent Ru intermediate layer was reduced to about 4 nm. X-ray diffraction results indicate an epitaxial orientation relationship of NiAl (110) // Ru (0002) between the two layers. Moreover, significant improvement of this epitaxial relationship was developed, which produced narrow c-axis distribution of the Ru intermediate layer with small grain size. The addition of the NiAl + SiO 2 seedlayer is a very promising approach to reduce the Ru intermediate layer grain size and eventually the magnetic layer grain size for perpendicular magnetic recording media without deterioration of other properties of thin films

  12. Channel modeling, signal processing and coding for perpendicular magnetic recording

    Science.gov (United States)

    Wu, Zheng

    With the increasing areal density in magnetic recording systems, perpendicular recording has replaced longitudinal recording to overcome the superparamagnetic limit. Studies on perpendicular recording channels including aspects of channel modeling, signal processing and coding techniques are presented in this dissertation. To optimize a high density perpendicular magnetic recording system, one needs to know the tradeoffs between various components of the system including the read/write transducers, the magnetic medium, and the read channel. We extend the work by Chaichanavong on the parameter optimization for systems via design curves. Different signal processing and coding techniques are studied. Information-theoretic tools are utilized to determine the acceptable region for the channel parameters when optimal detection and linear coding techniques are used. Our results show that a considerable gain can be achieved by the optimal detection and coding techniques. The read-write process in perpendicular magnetic recording channels includes a number of nonlinear effects. Nonlinear transition shift (NLTS) is one of them. The signal distortion induced by NLTS can be reduced by write precompensation during data recording. We numerically evaluate the effect of NLTS on the read-back signal and examine the effectiveness of several write precompensation schemes in combating NLTS in a channel characterized by both transition jitter noise and additive white Gaussian electronics noise. We also present an analytical method to estimate the bit-error-rate and use it to help determine the optimal write precompensation values in multi-level precompensation schemes. We propose a mean-adjusted pattern-dependent noise predictive (PDNP) detection algorithm for use on the channel with NLTS. We show that this detector can offer significant improvements in bit-error-rate (BER) compared to conventional Viterbi and PDNP detectors. Moreover, the system performance can be further improved by

  13. Effects of Cr-N-ZrO 2 seed layer formed on glass substrates for longitudinal recording media

    Science.gov (United States)

    Suzuki, Hiroyuki; Djayaprawira, David D.; Takahashi, Yoshio; Ishikawa, Akira; Ono, Toshinori; Yahisa, Yotsuo

    1999-03-01

    Effects of Cr-N-ZrO 2 seed layer deposited on glass substrates before the deposition of C/Co-Cr-Pt/Cr-Ti layers for longitudinal recording media have been investigated. The product of v and Is, the activation volume and the saturation magnetization per unit volume, media noise Nd and S0/ Nd, which is the half value of peak-to-peak output voltage of an isolated pulse over Nd at 11.8 kFC/mm, are evaluated. We find that vIs is decreased by adding N and ZrO 2 to Cr seed layer. Nd is reduced as vIs decreases by adding nitrogen to the Cr seed layer. This is mainly due to the decreased grain sizes of both Cr-Ti underlayer and Co-Cr-Pt magnetic layer. The Nd is further reduced by the addition of ZrO 2 to the Cr-N seed layer. Highest S0/ Nd is achieved for the media with Cr-N-ZrO 2 seed layer. On the other hand, the media with Cr-ZrO 2 seed layer deposited without nitrogen show the higher Nd. Therefore the decrease of the grain size by addition of nitrogen into Ar is essential to reduce Nd, and the ZrO 2 addition to the Cr-N seed layer seems to enhance the effect of grain size reduction by nitrogen addition.

  14. Destabilizing effect of time-dependent oblique magnetic field on magnetic fluids streaming in porous media.

    Science.gov (United States)

    El-Dib, Yusry O; Ghaly, Ahmed Y

    2004-01-01

    The present work studies Kelvin-Helmholtz waves propagating between two magnetic fluids. The system is composed of two semi-infinite magnetic fluids streaming throughout porous media. The system is influenced by an oblique magnetic field. The solution of the linearized equations of motion under the boundary conditions leads to deriving the Mathieu equation governing the interfacial displacement and having complex coefficients. The stability criteria are discussed theoretically and numerically, from which stability diagrams are obtained. Regions of stability and instability are identified for the magnetic fields versus the wavenumber. It is found that the increase of the fluid density ratio, the fluid velocity ratio, the upper viscosity, and the lower porous permeability play a stabilizing role in the stability behavior in the presence of an oscillating vertical magnetic field or in the presence of an oscillating tangential magnetic field. The increase of the fluid viscosity plays a stabilizing role and can be used to retard the destabilizing influence for the vertical magnetic field. Dual roles are observed for the fluid velocity in the stability criteria. It is found that the field frequency plays against the constant part for the magnetic field.

  15. High-coercive garnet films for thermo-magnetic recording

    International Nuclear Information System (INIS)

    Berzhansky, V N; Danishevskaya, Y V; Nedviga, A S; Milyukova, H T

    2016-01-01

    The possibility of using high-coercive of garnet films for thermo-magnetic recording is related with the presence of the metastable domain structure, which arises due to a significant mismatch of the lattice parameters of the film and the substrate. In the work the connection between facet crystal structure of elastically strained ferrite garnets films and the domain structure in them is established by methods of phase contrast and polarization microscopy. (paper)

  16. 7 CFR 1767.70 - Record storage media.

    Science.gov (United States)

    2010-01-01

    ... Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF... retention period provided for in the master index of records, unless there is a quality transfer from one... for accuracy and documented. (b) Each borrower shall implement internal control procedures that assure...

  17. 7 CFR 1770.4 - Record storage media.

    Science.gov (United States)

    2010-01-01

    ... Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF... the applicable retention period provided for in the master index of records, unless there is quality... must be verified for accuracy and documented. (b) Each borrower is required to implement internal...

  18. Magnetic resonance of porous media (MRPM): a perspective.

    Science.gov (United States)

    Song, Yi-Qiao

    2013-04-01

    Porous media are ubiquitous in our environment and their application is extremely broad. The common connection between these diverse materials is the importance of the microstructure (μm to mm scale) in determining the physical, chemical and biological functions and properties. Magnetic resonance and its imaging modality have been essential for noninvasive characterization of these materials, in the development of catalysts, understanding cement hydration, fluid transport in rocks and soil, geological prospecting, and characterization of tissue properties for medical diagnosis. The past two decades have witnessed significant development of MRPM that couples advances in physics, chemistry and engineering with a broad range of applications. This article will summarize key advances in basic physics and methodology, examine their limitations and envision future R&D directions. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. 26 CFR 1.6011-5 - Required use of magnetic media for corporate income tax returns.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Required use of magnetic media for corporate income tax returns. 1.6011-5 Section 1.6011-5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Tax Returns Or Statements § 1.6011-5 Required use of magnetic media for corporate incom...

  20. Improvement of the crystallographic orientation of double-layered perpendicular recording media by using CoCr (Mo)/Cu intermediate layers

    International Nuclear Information System (INIS)

    Tamai, Ichiro; Yamamoto, T.; Kikukawa, A.; Tanahashi, K.; Ishikawa, A.; Futamoto, M.

    2001-01-01

    We have introduced intermediate layers of CoCr/Cu and CoCrMo/Cu between a CoCrPtB recording layer and a soft-magnetic CoTaZr underlayer. The combination of the FCC-Cu first-intermediate layer and the HCP-CoCrMo second-intermediate layer was found to enhance the c-axis vertical orientation of the CoCrPtB recording layer. In media with intermediate layers of CoCrMo/Cu, the thickness of the intermediate layers can be reduced without sacrificing good magnetic properties, and this leads to high resolutions

  1. Temporal stability of superposed magnetic fluids in porous media

    International Nuclear Information System (INIS)

    Zakaria, Kadry; Sirwah, Magdy A; Alkharashi, Sameh

    2008-01-01

    The present work deals with the stability properties of time periodically streaming superposed magnetic fluids through porous media under the influence of an oblique alternating magnetic field. The system is composed of a middle fluid sheet of finite thickness embedded between two other bounded layers. The fluids are assumed to be incompressible and there are no volume charges in the layers of the fluids. Such configurations are of relevance in a variety of astrophysical and space configurations. The solutions of the linearized equations of motion and boundary conditions lead to deriving two more general simultaneous Mathieu equations of damping terms with complex coefficients. The method of multiple time scales is used to obtain approximate solutions and analyze the stability criteria for both the non-resonant and resonant cases and hence transition curves are obtained for such cases. The stability criteria are examined theoretically and numerically from which stability diagrams are obtained. It is found that the fluid sheet thickness plays a destabilizing role in the presence of a constant field and velocity, while the damping role is observed for the resonant cases. Dual roles are observed for the fluid velocity and the porosity in the stability criteria

  2. Reactively sputtered TeOx optical recording media

    International Nuclear Information System (INIS)

    Di Giulio, M.; Manno, D.; Micocci, G.; Rella, R.; Rizzo, A.; Tepore, A.

    1987-01-01

    Telluriom suboxide (TeO x ) thin films have been obtained by R.F. reactive sputtering deposition by using a Te target and an Ar-O 2 gas mixture. This technique of preparation has been shown to be a valid method because it is possible to easily obtain films with desired characteristics by an appropriate selection of the deposition conditions. Different samples were prepared by changing both the R.F. power (80-300 Watt) and the oxygen concentration in the sputtering gas. The films were analyzed in order to study their optical characteristics and the morphology before and after heat treatment. In particular, transmissivity and reflectivity have been found to change markedly by thermal treatment and critical temperatures in the range 120-150 grades centigrade. This property makes these films suitable for optical recording with a low output power laser diode

  3. Innovative uses of electronic health records and social media for public health surveillance.

    Science.gov (United States)

    Eggleston, Emma M; Weitzman, Elissa R

    2014-03-01

    Electronic health records (EHRs) and social media have the potential to enrich public health surveillance of diabetes. Clinical and patient-facing data sources for diabetes surveillance are needed given its profound public health impact, opportunity for primary and secondary prevention, persistent disparities, and requirement for self-management. Initiatives to employ data from EHRs and social media for diabetes surveillance are in their infancy. With their transformative potential come practical limitations and ethical considerations. We explore applications of EHR and social media for diabetes surveillance, limitations to approaches, and steps for moving forward in this partnership between patients, health systems, and public health.

  4. Femtosecond recording of holograms and hologram-like structures in volume recording media

    International Nuclear Information System (INIS)

    Dement'ev, D A; Kompanets, V O; Matveets, Yu A; Serov, O B; Chekalin, Sergei V; Smolovich, A M

    2001-01-01

    Reflection holograms in thick layers of bichromated gelatin are recorded by using 50-fs pulses of the second harmonic of a Ti:sapphire laser. (laser applications and other topics in quantum electronics)

  5. Noise Reduction Based on an Fe -Rh Interlayer in Exchange-Coupled Heat-Assisted Recording Media

    Science.gov (United States)

    Vogler, Christoph; Abert, Claas; Bruckner, Florian; Suess, Dieter

    2017-11-01

    High storage density and high data rate are two of the most desired properties of modern hard disk drives. Heat-assisted magnetic recording (HAMR) is believed to achieve both. Recording media, consisting of exchange-coupled grains with a high and a low TC part, were shown to have low dc noise—but increased ac noise—compared to hard magnetic single-phase grains like FePt. We extensively investigate the influence of an Fe -Rh interlayer on the magnetic noise in exchange-coupled grains. We find an optimal grain design that reduces the jitter in the down-track direction by up to 30% and in the off-track direction by up to 50%, depending on the head velocity, compared to the same structures without FeRh. Furthermore, the mechanisms causing this jitter reduction are demonstrated. Additionally, we show that, for short heat pulses and low write temperatures, the switching-time distribution of the analyzed grain structure is reduced by a factor of 4 compared to the same structure without an Fe -Rh layer. This feature could be interesting for HAMR use with a pulsed laser spot and could encourage discussion of this HAMR technique.

  6. Branched flow and caustics in random media with magnetic fields

    Science.gov (United States)

    Metzger, Jakob; Fleischmann, Ragnar; Geisel, Theo

    2009-03-01

    Classical particles as well as quantum mechanical waves exhibit complex behaviour when propagating through random media. One of the dominant features of the dynamics in correlated, weak disorder potentials is the branching of the flow. This can be observed in several physical systems, most notably in the electron flow in two-dimensional electron gases [1], and has also been used to describe the formation of freak waves [2]. We present advances in the theoretical understanding and numerical simulation of classical branched flows in magnetic fields. In particular, we study branching statistics and branch density profiles. Our results have direct consequences for experiments which measure transport properties in electronic systems [3].[1] e.g. M. A. Topinka et al., Nature 410, 183 (2001), M. P. Jura et al., Nature Physics 3, 841 (2007)[2] E. J. Heller, L. Kaplan and A. Dahlen, J. Geophys. Res., 113, C09023 (2008)[3] J. J. Metzger, R. Fleischmann and T. Geisel, in preparation

  7. The study and development of magnetic recording heads. A thin film integrated magnetic head

    International Nuclear Information System (INIS)

    Lazzari, Jean-Pierre

    1970-01-01

    A new integrated magnetic head is described. The head was made by vacuum deposition using a mask. A magnetically coupled multilayer construction led to high performance. The results obtained indicate that the device functions equally well, for reading and writing. A set of calculations was developed which could simulate and optimize the behavior of the recording head. The results obtained with the writing were in good agreement with those obtained from experiments and quite different from results which have been several times previously published. In addition a new method was developed for measuring high fields in confined spaces; a 1000 A diameter probe was used in conjunction with a low angle diffraction procedure. The measurements give results which are very different from those obtained by current theories based on the magnetic potentials at the surface. (author) [fr

  8. Coupled granular/continuous medium for thermally stable perpendicular magnetic recording

    International Nuclear Information System (INIS)

    Sonobe, Y.; Weller, D.; Ikeda, Y.; Takano, K.; Schabes, M.E.; Zeltzer, G.; Do, H.; Yen, B.K.; Best, M.E.

    2001-01-01

    We studied coupled granular/continuous (CGC) perpendicular media consisting of a continuous multilayer structure and a granular layer. The addition of Co/Pt multilayers decreased the nucleation field from 200 to -1800 Oe and increased the squareness from 0.9 to 1.0. The moment decay at room temperature was significantly reduced from -4.8% to -0.05% per decade. At elevated temperatures, strong exchange coupling between a granular layer and a continuous layer is needed for thermal stability. The exchange-coupled continuous layer reduces thermal demagnetization as it effectively increases the grain size, tightens the grain distribution, and prevents the reversal of individual grains. Magnetic Force Microscope image showed a larger magnetic cluster size for the CGC structure. Compared to the CoCr 18 Pt 12 medium, the CGC medium had 2.3 dB higher output. However, the noise for the CGC medium increased with the recording density, while the noise for the CoCr 18 Pt 12 medium remained constant from 4 to 15 kfc/mm. Further optimization and noise reduction are still required for future high density recording

  9. Coupled granular/continuous medium for thermally stable perpendicular magnetic recording

    Science.gov (United States)

    Sonobe, Y.; Weller, D.; Ikeda, Y.; Takano, K.; Schabes, M. E.; Zeltzer, G.; Do, H.; Yen, B. K.; Best, M. E.

    2001-10-01

    We studied coupled granular/continuous (CGC) perpendicular media consisting of a continuous multilayer structure and a granular layer. The addition of Co/Pt multilayers decreased the nucleation field from 200 to -1800 Oe and increased the squareness from 0.9 to 1.0. The moment decay at room temperature was significantly reduced from -4.8% to -0.05% per decade. At elevated temperatures, strong exchange coupling between a granular layer and a continuous layer is needed for thermal stability. The exchange-coupled continuous layer reduces thermal demagnetization as it effectively increases the grain size, tightens the grain distribution, and prevents the reversal of individual grains. Magnetic Force Microscope image showed a larger magnetic cluster size for the CGC structure. Compared to the CoCr 18Pt 12 medium, the CGC medium had 2.3 dB higher output. However, the noise for the CGC medium increased with the recording density, while the noise for the CoCr 18Pt 12 medium remained constant from 4 to 15 kfc/mm. Further optimization and noise reduction are still required for future high density recording.

  10. Rotational magnetization of anisotropic media: Lag angle, ellipticity and accommodation

    International Nuclear Information System (INIS)

    Kahler, G.R.; Della Torre, E.

    2006-01-01

    This paper discusses the change in the ellipticity of two-dimensional magnetization trajectories as the applied field rotates from the easy axis to the hard axis of a material. Furthermore, the impact that the reversible magnetization has on the ellipticity is discussed, including the relationship between the magnetization squareness and the reversible component of the magnetization

  11. Architecture of portable electronic medical records system integrated with streaming media.

    Science.gov (United States)

    Chen, Wei; Shih, Chien-Chou

    2012-02-01

    Due to increasing occurrence of accidents and illness during business trips, travel, or overseas studies, the requirement for portable EMR (Electronic Medical Records) has increased. This study proposes integrating streaming media technology into the EMR system to facilitate referrals, contracted laboratories, and disease notification among hospitals. The current study encoded static and dynamic medical images of patients into a streaming video format and stored them in a Flash Media Server (FMS). Based on the Taiwan Electronic Medical Record Template (TMT) standard, EMR records can be converted into XML documents and used to integrate description fields with embedded streaming videos. This investigation implemented a web-based portable EMR interchanging system using streaming media techniques to expedite exchanging medical image information among hospitals. The proposed architecture of the portable EMR retrieval system not only provides local hospital users the ability to acquire EMR text files from a previous hospital, but also helps access static and dynamic medical images as reference for clinical diagnosis and treatment. The proposed method protects property rights of medical images through information security mechanisms of the Medical Record Interchange Service Center and Health Certificate Authorization to facilitate proper, efficient, and continuous treatment of patients.

  12. Decoding of digital magnetic recording with longitudinal magnetization of a tape from a magneto-optical image of stray fields

    Science.gov (United States)

    Lisovskii, F. V.; Mansvetova, E. G.

    2017-05-01

    For digital magnetic recording of encoded information with longitudinal magnetization of the tape, the connection between the domain structure of a storage medium and magneto-optical image of its stray fields obtained using a magnetic film with a perpendicular anisotropy and a large Faraday rotation has been studied. For two-frequency binary code without returning to zero, an algorithm is developed, that allows uniquely decoding of the information recorded on the tape based on analysis of an image of stray fields.

  13. Modeling of the write and read back performances of hexagonal Ba-ferrite particulate media for high density tape recording

    International Nuclear Information System (INIS)

    Lee, Jehyun; Fuger, Markus; Fidler, Josef; Suess, Dieter; Schrefl, Thomas; Shimizu, Osamu

    2010-01-01

    In this study, the signal-to-noise ratio (SNR) performances of longitudinally, randomly, and perpendicularly oriented particles, based on hexagonal barium ferrite (h-BaFe) platelets with an average volume of 2400 nm 3 have been studied as a function of the recording head to media distance by numerical micromagnetic simulations. The distances from the write head to media and from the read head to media were varied independently. For a fixed read distance and varied writing distances, the SNR was decreasing in larger write distance. An optimum write distance of 40 and 50 nm was found for the longitudinally oriented media and the perpendicularly oriented media, respectively. The optimum write distance for longitudinally oriented media, 40 nm, resulted in the local minimum SNR for the perpendicularly oriented media. In most write distances the perpendicularly oriented media show the outstanding best performance, but near the write distance of 40 nm the longitudinally oriented media work as good as the perpendicularly oriented media. In a fixed write distance with various read distances, the SNR was almost constant in each media whereas the average signal amplitude was exponentially decayed in larger read head to media distance. The best SNR was found in the perpendicularly oriented media at write head to media distance d write =20 nm and read head to media distance d read =40 nm. The best SNR value is 11.9 and 24.4 dB in time domain and frequency domain, respectively.

  14. Use of bias sputtering to enhance decoupling in oxide composite perpendicular recording media

    International Nuclear Information System (INIS)

    Lee, Hwan-Soo; Bain, James A.; Laughlin, David E.

    2007-01-01

    The effects of substrate bias on two types of oxide composite perpendicular recording media CoCrPt-SiO 2 and FePt-MgO were investigated. The use of substrate bias greatly modified the thin film microstructure and resulted in the enhanced grain decoupling in the films. The growth characteristics due to preferential resputtering were interpreted to arise mainly from weak surface bonding to the growing films for nontextured growth, combined with strong cohesion for the textured growth

  15. Structural stability of hydrogenated amorphous carbon overcoats used in heat-assisted magnetic recording investigated by rapid thermal annealing

    KAUST Repository

    Wang, N.; Komvopoulos, K.; Rose, F.; Marchon, B.

    2013-01-01

    Ultrathin amorphous carbon (a-C) films are extensively used as protective overcoats of magnetic recording media. Increasing demands for even higher storage densities have necessitated the development of new storage technologies, such as heat-assisted magnetic recording (HAMR), which uses laser-assisted heating to record data on high-stability media that can store single bits in extremely small areas (∼1 Tbit/in.2). Because HAMR relies on locally changing the coercivity of the magnetic medium by raising the temperature above the Curie temperature for data to be stored by the magnetic write field, it raises a concern about the structural stability of the ultrathin a-C film. In this study, rapid thermal annealing (RTA) experiments were performed to examine the thermal stability of ultrathin hydrogenated amorphous carbon (a-C:H) films deposited by plasma-enhanced chemical vapor deposition. Structural changes in the a-C:H films caused by RTA were investigated by x-ray photoelectron spectroscopy, Raman spectroscopy, x-ray reflectivity, and conductive atomic force microscopy. The results show that the films exhibit thermal stability up to a maximum temperature in the range of 400-450 °C. Heating above this critical temperature leads to hydrogen depletion and sp 2 clustering. The critical temperature determined by the results of this study represents an upper bound of the temperature rise due to laser heating in HAMR hard-disk drives and the Curie temperature of magnetic materials used in HAMR hard disks. © 2013 American Institute of Physics.

  16. Mineral magnetic environmental record in clastic cave deposits

    Czech Academy of Sciences Publication Activity Database

    Šlechta, Stanislav; Kadlec, Jaroslav

    2008-01-01

    Roč. 38, special issue (2008), s. 134-134 ISSN 1335-2806. [Paleo, Rock and Environmental Magnetism. Castle Meeting /11./. 22.06.2008-28.06.2008, Bojnice] Institutional research plan: CEZ:AV0Z30130516 Keywords : mineral magnetic environmental reconstruction * cave sediments * Moravian Karst Subject RIV: DE - Earth Magnetism, Geodesy, Geography

  17. Influence of writing and reading intertrack interferences in terms of bit aspect ratio in shingled magnetic recording

    Science.gov (United States)

    Nobuhara, Hirofumi; Okamoto, Yoshihiro; Yamashita, Masato; Nakamura, Yasuaki; Osawa, Hisashi; Muraoka, Hiroaki

    2014-05-01

    In this paper, we investigate the influence of the writing and reading intertrack interferences (ITIs) in terms of bit aspect ratio (BAR) in shingled magnetic recording by computer simulation using a read/write model which consists of a writing process based on Stoner-Wohlfarth switching asteroid by a one-side shielded isosceles triangular write head and a reading process by an around shielded read head for a discrete Voronoi medium model. The results show that BAR should be 3 to reduce the influence of writing and reading ITIs, media noise, and additive white Gaussian noise in an assumed areal density of 4.61Tbpsi.

  18. Thermal modeling of head disk interface system in heat assisted magnetic recording

    Energy Technology Data Exchange (ETDEWEB)

    Vemuri, Sesha Hari; Seung Chung, Pil; Jhon, Myung S., E-mail: mj3a@andrew.cmu.edu [Department of Chemical Engineering and Data Storage Systems Center, Carnegie Mellon University, 5000 Forbes Ave., Pittsburgh, Pennsylvania 15213 (United States); Min Kim, Hyung [Department of Mechanical System Engineering, Kyonggi University, Suwon, Gyeonggi-do 440-746 (Korea, Republic of)

    2014-05-07

    A thorough understanding of the temperature profiles introduced by the heat assisted magnetic recording is required to maintain the hotspot at the desired location on the disk with minimal heat damage to other components. Here, we implement a transient mesoscale modeling methodology termed lattice Boltzmann method (LBM) for phonons (which are primary carriers of energy) in the thermal modeling of the head disk interface (HDI) components, namely, carbon overcoat (COC). The LBM can provide more accurate results compared to conventional Fourier methodology by capturing the nanoscale phenomena due to ballistic heat transfer. We examine the in-plane and out-of-plane heat transfer in the COC via analyzing the temperature profiles with a continuously focused and pulsed laser beam on a moving disk. Larger in-plane hotspot widening is observed in continuously focused laser beam compared to a pulsed laser. A pulsed laser surface develops steeper temperature gradients compared to continuous hotspot. Furthermore, out-of-plane heat transfer from the COC to the media is enhanced with a continuous laser beam then a pulsed laser, while the temperature takes around 140 fs to reach the bottom surface of the COC. Our study can lead to a realistic thermal model describing novel HDI material design criteria for the next generation of hard disk drives with ultra high recording densities.

  19. High-density near-field optical disc recording using phase change media and polycarbonate substrate

    Science.gov (United States)

    Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu

    2004-09-01

    We developed a high density near field optical recording disc system with a solid immersion lens and two laser sources. In order to realize the near field optical recording, we used a phase change recording media and a molded polycarbonate substrate. The near field optical pick-up consists of a solid immersion lens with numerical aperture of 1.84. The clear eye pattern of 90.2 GB capacity (160nm track pitch and 62 nm per bit) was observed. The jitter using a limit equalizer was 10.0 % without cross-talk. The bit error rate using an adaptive PRML with 8 taps was 3.7e-6 without cross-talk. We confirmed that the near field optical disc system is a promising technology for a next generation high density optical disc system.

  20. Automation of Presentation Record Production Based on Rich-Media Technology Using SNT Petri Nets Theory

    Directory of Open Access Journals (Sweden)

    Ivo Martiník

    2015-01-01

    Full Text Available Rich-media describes a broad range of digital interactive media that is increasingly used in the Internet and also in the support of education. Last year, a special pilot audiovisual lecture room was built as a part of the MERLINGO (MEdia-rich Repository of LearnING Objects project solution. It contains all the elements of the modern lecture room determined for the implementation of presentation recordings based on the rich-media technologies and their publication online or on-demand featuring the access of all its elements in the automated mode including automatic editing. Property-preserving Petri net process algebras (PPPA were designed for the specification and verification of the Petri net processes. PPPA does not need to verify the composition of the Petri net processes because all their algebraic operators preserve the specified set of the properties. These original PPPA are significantly generalized for the newly introduced class of the SNT Petri process and agent nets in this paper. The PLACE-SUBST and ASYNC-PROC algebraic operators are defined for this class of Petri nets and their chosen properties are proved. The SNT Petri process and agent nets theory were significantly applied at the design, verification, and implementation of the programming system ensuring the pilot audiovisual lecture room functionality.

  1. Flat super-oscillatory lens for heat-assisted magnetic recording with sub-50 nm resolution.

    Science.gov (United States)

    Yuan, Guanghui; Rogers, Edward T F; Roy, Tapashree; Shen, Zexiang; Zheludev, Nikolay I

    2014-03-24

    Heat-assisted magnetic recording (HAMR) is a future roadmap technology to overcome the superparamagnetic limit in high density magnetic recording. Existing HAMR schemes depend on a simultaneous magnetic stimulation and light-induced local heating of the information carrier. To achieve high-density recorded data, near-field plasmonic transducers have been proposed as light concentrators. Here we suggest and investigate in detail an alternative approach exploiting a far-field focusing device that can focus light into sub-50 nm hot-spots in the magnetic recording layer using a laser source operating at 473 nm. It is based on a recently introduced super-oscillatory flat lens improved with the use of solid immersion, giving an effective numerical aperture as high as 4.17. The proposed solution is robust and easy to integrate with the magnetic recording head thus offering a competitive advantage over plasmonic technology.

  2. Propagation of electromagnetic waves in stratified media with nonlinearity in both dielectric and magnetic responses.

    Science.gov (United States)

    Kim, Kihong; Phung, D K; Rotermund, F; Lim, H

    2008-01-21

    We develop a generalized version of the invariant imbedding method, which allows us to solve the electromagnetic wave equations in arbitrarily inhomogeneous stratified media where both the dielectric permittivity and magnetic permeability depend on the strengths of the electric and magnetic fields, in a numerically accurate and efficient manner. We apply our method to a uniform nonlinear slab and find that in the presence of strong external radiation, an initially uniform medium of positive refractive index can spontaneously change into a highly inhomogeneous medium where regions of positive or negative refractive index as well as metallic regions appear. We also study the wave transmission properties of periodic nonlinear media and the influence of nonlinearity on the mode conversion phenomena in inhomogeneous plasmas. We argue that our theory is very useful in the study of the optical properties of a variety of nonlinear media including nonlinear negative index media fabricated using wires and split-ring resonators.

  3. Efficiently reducing transition curvature in heat-assisted magnetic recording with state-of-the-art write heads

    Science.gov (United States)

    Vogler, Christoph; Abert, Claas; Bruckner, Florian; Suess, Dieter

    2017-05-01

    Curvatures of bit transitions on granular media are a serious problem for the read-back process. We address this fundamental issue and propose a possibility to efficiently reduce transition curvatures with state-of-the-art heat-assisted magnetic recording heads. We compare footprints of conventional with those of the proposed head design on different media, consisting of exchange coupled and single phase grains. Additionally, we investigate the impact of various recording parameters, such as the full width at half maximum (FWHM) of the applied heat pulse and the coercivity gradient near the write temperature of the recording grains. The footprints are calculated with a coarse grained model, based on the Landau-Lifshitz-Bloch equation. The presented simulations show a transition curvature reduction of up to 40%, in the case of a medium with exchange coupled grains and a heat pulse with a FWHM of 40 nm. We further give the reason for the straightening of the bit transitions, by means of basic considerations with regard to the effective recording time window of the write process. Besides the transition curvature reduction, the proposed head design yields an improvement of the transition jitter in both down-track and off-track directions.

  4. Origin of magnetic switching field distribution in bit patterned media based on pre-patterned substrates

    OpenAIRE

    Pfau , B; Günther , C.M.; Guehrs , E; Hauet , Thomas; Yang , H; Vinh , L.; Xu , X; Yaney , D; Rick , R; Eisebitt , S; Hellwig , O

    2011-01-01

    International audience; Using a combination of synchrotron radiation based magnetic imaging and high-resolution transmission electron microscopy we reveal systematic correlations between the magnetic switching field and the internal nanoscale structure of individual islands in bit patterned media fabricated by Co/Pd-multilayer deposition onto pre-patterned substrates. We find that misaligned grains at the island periphery are a common feature independent of the island switching field, while i...

  5. The Relationship Between Magnet Designation, Electronic Health Record Adoption, and Medicare Meaningful Use Payments.

    Science.gov (United States)

    Lippincott, Christine; Foronda, Cynthia; Zdanowicz, Martin; McCabe, Brian E; Ambrosia, Todd

    2017-08-01

    The objective of this study was to examine the relationship between nursing excellence and electronic health record adoption. Of 6582 US hospitals, 4939 were eligible for the Medicare Electronic Health Record Incentive Program, and 6419 were eligible for evaluation on the HIMSS Analytics Electronic Medical Record Adoption Model. Of 399 Magnet hospitals, 330 were eligible for the Medicare Electronic Health Record Incentive Program, and 393 were eligible for evaluation in the HIMSS Analytics Electronic Medical Record Adoption Model. Meaningful use attestation was defined as receipt of a Medicare Electronic Health Record Incentive Program payment. The adoption electronic health record was defined as Level 6 and/or 7 on the HIMSS Analytics Electronic Medical Record Adoption Model. Logistic regression showed that Magnet-designated hospitals were more likely attest to Meaningful Use than non-Magnet hospitals (odds ratio = 3.58, P electronic health records than non-Magnet hospitals (Level 6 only: odds ratio = 3.68, P electronic health record use, which involves earning financial incentives for successful adoption. Continued investigation is needed to examine the relationships between the quality of nursing care, electronic health record usage, financial implications, and patient outcomes.

  6. Ferromagnetic resonance and transverse susceptibility measurements on particulate recording media (abstract)

    Science.gov (United States)

    Orth, Th.; Pelzl, J.; Chantrell, R. W.; Veitch, R.; Jakusch, H.

    1993-05-01

    The FMR absorption of different particulate recording tapes was investigated at microwave frequencies in the X band and Q band using temperatures from 70 to 400 K. The FMR spectra as a function of the external magnetic field were recorded for four different orientations of the static and high frequency magnetic fields with respect to the tape. Particular interest of the experimental and theoretical study was devoted to the interaction fields between the particles, texture effects within the tape sample and the effective anisotropy fields. Tape samples with different particle materials, varying packing densities and orientation ratios were prepared. The shape and line position of the FMR spectra obtained are strongly dependent on the pigment material and the tape parameters mentioned above. The experimental data are compared with theoretical calculations, based on a phenomenological model and a computer simulation. This comparison gives information on the orientational distribution of the particles, which is the most important source for inhomogeneous line broadening, the mean interaction, and anisotropy fields which govern the line position, the effective magnetization of the tape, and the relaxation time. The influence of the crystalline anisotropy can be investigated via temperature dependent measurements. The results are proved by additional transverse susceptibility measurements.

  7. Paleomagnetism. Solar nebula magnetic fields recorded in the Semarkona meteorite.

    Science.gov (United States)

    Fu, Roger R; Weiss, Benjamin P; Lima, Eduardo A; Harrison, Richard J; Bai, Xue-Ning; Desch, Steven J; Ebel, Denton S; Suavet, Clément; Wang, Huapei; Glenn, David; Le Sage, David; Kasama, Takeshi; Walsworth, Ronald L; Kuan, Aaron T

    2014-11-28

    Magnetic fields are proposed to have played a critical role in some of the most enigmatic processes of planetary formation by mediating the rapid accretion of disk material onto the central star and the formation of the first solids. However, there have been no experimental constraints on the intensity of these fields. Here we show that dusty olivine-bearing chondrules from the Semarkona meteorite were magnetized in a nebular field of 54 ± 21 microteslas. This intensity supports chondrule formation by nebular shocks or planetesimal collisions rather than by electric currents, the x-wind, or other mechanisms near the Sun. This implies that background magnetic fields in the terrestrial planet-forming region were likely 5 to 54 microteslas, which is sufficient to account for measured rates of mass and angular momentum transport in protoplanetary disks. Copyright © 2014, American Association for the Advancement of Science.

  8. Solar nebula magnetic fields recorded in the Semarkona meteorite

    DEFF Research Database (Denmark)

    Fu, Roger R.; Weiss, Benjamin P.; Lima, Eduardo A.

    2014-01-01

    on the intensity of these fields. Here we show that dusty olivine-bearing chondrules from the Semarkona meteorite were magnetized in a nebular field of 54 ± 21 microteslas. This intensity supports chondrule formation by nebular shocks or planetesimal collisions rather than by electric currents, the x......-wind, or other mechanisms near the Sun. This implies that background magnetic fields in the terrestrial planet-forming region were likely 5 to 54 microteslas, which is sufficient to account for measured rates of mass and angular momentum transport in protoplanetary disks....

  9. Field dependence of magnetic viscosity of CoCrTa in-plane media

    NARCIS (Netherlands)

    Phan le kim, P.L.K.; Lodder, J.C.; Popma, T.J.A.

    1999-01-01

    In this paper we will present a study of magnetic viscosity as a function of applied field of CoCrTa/Cr in-plane media. The viscosity versus applied field curves (viscosity curves) of the samples exhibit a sharp peak at remanence coercivity (Hcr). Their activation volume was found to be close to the

  10. Tumor microvascular changes in antiangiogenic treatment : Assessment by magnetic resonance contrast media of different molecular weights

    NARCIS (Netherlands)

    Turetschek, K; Preda, A; Novikov, [No Value; Brasch, RC; Weinmann, HJ; Wunderbaldinger, P; Roberts, TPL

    Purpose: To test magnetic resonance (MR) contrast media of different molecular weights (MWs) for their potential to characterize noninvasively microvascular changes in an experimental tumor treatment model. Materials and Methods: MD-MBA-435, a poorly differentiated human breast cancer cell line, was

  11. Magnetic record associated with tree ring density: Possible climate proxy

    Czech Academy of Sciences Publication Activity Database

    Kletetschka, Günther; Pruner, Petr; Venhodová, Daniela; Kadlec, Jaroslav

    2007-01-01

    Roč. 8, - (2007), s. 1-11 ISSN 1467-4866 Institutional research plan: CEZ:AV0Z3013912 Keywords : palaeo-climatic indicator * sequoia tree * magnetic properties Subject RIV: DB - Geology ; Mineralogy Impact factor: 1.842, year: 2007

  12. 75 FR 70705 - Records Schedules; Availability and Request for Comments

    Science.gov (United States)

    2010-11-18

    ... Federal agencies create billions of records on paper, film, magnetic tape, and other media. To control... information system containing lessons learned from transport airplane accidents. Proposed for permanent...

  13. Linear response theory for magnetic Schrodinger operators in disordered media

    CERN Document Server

    Bouclet, J M; Klein, A; Schenker, J

    2004-01-01

    We justify the linear response theory for an ergodic Schrodinger operator with magnetic field within the non-interacting particle approximation, and derive a Kubo formula for the electric conductivity tensor. To achieve that, we construct suitable normed spaces of measurable covariant operators where the Liouville equation can be solved uniquely. If the Fermi level falls into a region of localization, we recover the well-known Kubo-Streda formula for the quantum Hall conductivity at zero temperature.

  14. The role of MFM signal in mark size measurement in probe-based magnetic recording on CoNi/Pt multilayers

    International Nuclear Information System (INIS)

    Zhang Li; Bain, James A.; Zhu Jiangang; Abelmann, Leon; Onoue, Takahiro

    2007-01-01

    A method of heat-assisted magnetic recording (HAMR) potentially suitable for probe-based storage systems is characterized. Magnetic marks were formed by a scanning tunneling microscopy (STM)-based thermal magnetic mechanism on a perpendicular CoNi/Pt multilayered film. Magnetic force microscopy (MFM) was applied to display those marks. The MFM signal is dependent of the lift-height during MFM scanning: smaller lift-height leads to higher resolution of the MFM image and a double-peak signal line, while higher lift-height leads to lower resolution and a single-peak signal line. Theoretical calculation of the magnetic field from the mark was executed. It agrees well with experiments, and demonstrates the method of mark size measurement in perpendicular media: full-width half-maximum (FWHM) of the measured MFM signal

  15. Oblique sputtered and evaporated magnetic thin films for tape recording

    NARCIS (Netherlands)

    Bijker, M.D.

    1998-01-01

    After having introduced some aspects of tape recording in chapter one, chapter two deals with the magnetron sputtering process itself. The kinetic energy of the electrons which are bound to the groove region by the combined action of the B and E field, was calculated. It was found that for a

  16. Cover-layer with High Refractive Index for Near-Field Recording Media

    Science.gov (United States)

    Kim, Jin-Hong; Lee, Jun-Seok

    2007-06-01

    TiO2 nanoparticles are added into UV-curable resin to increase the refractive index of the cover-layer laminated for cover-layer incident near-field recording media. A high refractive index is required for the cover-layer operating with an optical head with a high numerical aperture. The eye pattern from a cover-layer coated 20 GB read-only memory disc in which the refractive index of the cover-layer is 1.75 is achieved, but the gap servo is unstable owing to the rough surface of the cover-layer. Even though the light loss due to the nanoparticles is negligible, a rough microstructure is developed by adding the nanoparticles into an organic binder material. To achieve a smooth surface for a stable gap servo, the solubility of the nanoparticles should be enhanced by the optimization of the surface of the nanoparticles.

  17. Integrated optical isolators using magnetic surface plasmon (Presentation Recording)

    Science.gov (United States)

    Shimizu, Hiromasa; Kaihara, Terunori; Umetsu, Saori; Hosoda, Masashi

    2015-09-01

    Optical isolators are one of the essential components to protect semiconductor laser diodes (LDs) from backward reflected light in integrated optics. In order to realize optical isolators, nonreciprocal propagation of light is necessary, which can be realized by magnetic materials. Semiconductor optical isolators have been strongly desired on Si and III/V waveguides. We have developed semiconductor optical isolators based on nonreciprocal loss owing to transverse magneto-optic Kerr effect, where the ferromagnetic metals are deposited on semiconductor optical waveguides1). Use of surface plasmon polariton at the interface of ferromagnetic metal and insulator leads to stronger optical confinement and magneto-optic effect. It is possible to modulate the optical confinement by changing the magnetic field direction, thus optical isolator operation is proposed2, 3). We have investigated surface plasmons at the interfaces between ferrimagnetic garnet/gold film, and applications to waveguide optical isolators. We assumed waveguides composed of Au/Si(38.63nm)/Ce:YIG(1700nm)/Si(220nm)/Si , and calculated the coupling lengths between Au/Si(38.63nm)/Ce:YIG plasmonic waveguide and Ce:YIG/Si(220nm)/Si waveguide for transversely magnetized Ce:YIG with forward and backward directions. The coupling length was calculated to 232.1um for backward propagating light. On the other hand, the coupling was not complete, and the length was calculated to 175.5um. The optical isolation by using the nonreciprocal coupling and propagation loss was calculated to be 43.7dB when the length of plasmonic waveguide is 700um. 1) H. Shimizu et al., J. Lightwave Technol. 24, 38 (2006). 2) V. Zayets et al., Materials, 5, 857-871 (2012). 3) J. Montoya, et al, J. Appl. Phys. 106, 023108, (2009).

  18. Magnetic paleointensities recorded in fault pseudotachylytes and implications for earthquake lightnings

    Science.gov (United States)

    Leibovitz, Natalie; Ferré, Eric; Geissman, John; Gattacceca, Jérôme

    2015-04-01

    Fault pseudotachylytes commonly form by frictional melting due to seismic slip. These fine-grained clastic rocks result from melt quenching and may show a high concentration of fine ferromagnetic grains. These grains are potentially excellent recorders of the rock natural remanent magnetization (NRM). The magnetization processes of fault pseudotachylytes are complex and may include the following: i) near coseismic thermal remanent magnetization (TRM) acquired upon cooling of the melt; ii) coseismic lightning induced remanent magnetization (LIRM) caused by earthquake lightnings (EQL); iii) post seismic chemical remanent magnetization (CRM) related to both devitrification and alteration. Deciphering these magnetization components is crucial to the interpretation of microstructures and the timing of microstructural development. Hence the paleomagnetic record of fault pseudotachylytes provides an independent set of new constraints on coseismic and post-seismic deformation. Fault pseudotachylytes from the Santa Rosa Mountains, California host a magnetic assemblage dominated by stoichiometric magnetite, formed from the breakdown of ferromagnesian silicates and melt oxidation at high temperature. Magnetite grain size in these pseudotachylytes compares to that of magnetites formed in friction experiments. Paleomagnetic data on these 59 Ma-old fault rocks reveal not only anomalous magnetization directions, inconsistent with the coseismic geomagnetic field, but also anomalously high magnetization intensities. Here we discuss preliminary results of paleointensity experiments designed to quantify the intensity of coseismic magnetizing fields. The REM' paleointensity method is particularly well suited to investigate NRMs resulting from non-conventional and multiple magnetization processes. The anomalously high NRM recorded in a few, but not all, specimens points to LIRM as the dominant origin of magnetization.

  19. Indication-related dosing for magnetic resonance contrast media

    International Nuclear Information System (INIS)

    Yuh, W.T.C.; Parker, J.R.; Carvlin, M.J.

    1997-01-01

    This presentation reviews the issue of contrast media dosing and imaging protocols for the optimal MR imaging detection and characterization of pathology. The cumulative clinical experience gained in performing contrast-enhanced MR examinations with gadolinium chelates indicates that a dose of 0.1 mmol/kg body weight provides safe and effective enhancement of most CNS pathology. Doses lower than 0.1 mmol/kg have been shown to be inadequate for delineating all but selected types of CNS pathology, such as masses with a high lesion to background ratio on post-contrast images (acoustic neuromas) or lesions located in areas in which the normal tissue very rapidly takes up contrast agent (e. g. microadenomas in the pituitary gland). Recent clinical studies have suggested a role for high dose gadolinium administration (up to 0.3 mmol/kg) for the optimal detection and delineation of cerebral metastases or other small or poorly enhancing lesions. Differences in the histopathologic characteristics (capillary permeability, vascularity, location, size) of specific diseased tissues may require varying doses or even a different contrast agent to be used for optimal imaging results. As new MR contrast agents and new scanning techniques are introduced, the specific diagnostic question posed will likely determine the choice of pulse sequence, contrast agent and dose used. (orig.)

  20. Perfusion imaging with magnetic-susceptibility contrast media

    International Nuclear Information System (INIS)

    Rosen, B.R.; Belliveau, J.W.; Betteridge, D.; Cohen, M.S.; Weisskoff, R.M.; Vevea, J.M.; Rzedzian, R.P.; Brady, T.J.

    1989-01-01

    In animal models, transient signal los on T2-weighted images has been well documented following intravenous injection of high-magnetic-susceptibility contrast agents that are compartmentalized within the brain intravascular space. These signal changes have been correlated with physiologic parameters, such as blood flow and volume. The advent of whole-body single-shot imaging capability, coupled with the approval of paramagnetic contrasts agents for human use, has enabled the authors to demonstrate susceptibility contrast in the human brain, allowing for generation of functional images. With use of a 1.5-T imaging system gradient-echo images (TE = 60 msec) were acquired in 75 msec. Sequential single-sections images were sampled every 1 second following bolus administration of 0.1 mmol/kg of Gd-DTPA

  1. Mechanism of nuclear cross-relaxation in magnetically ordered media

    Energy Technology Data Exchange (ETDEWEB)

    Buishvili, L L; Volzhan, E B; Giorgadze, N P [AN Gruzinskoj SSR, Tbilisi. Inst. Fiziki

    1975-09-01

    A mechanism of two-step nuclear relaxation in magnetic ordered dielectrics is proposed. The case is considered where the energy conservation in the cross relaxation (CR) process is ensured by the lattice itself without spin-spin interactions. Expressions have been obtained describing the temperature dependence of the CR rate. For a nonuniform broadened NMR line it has been shown that the spin-lattice relaxation time for a spin packet taken out from the equilibrium may be determined by the CR time owing to the mechanism suggested. When the quantization axes for electron and nuclear spins coincide, the spin-lattice relaxation is due to the three-magnon mechanism. The cross-relaxation stage has been shown to play a significant role in the range of low temperatures (T<10 deg K) and to become negligible with a temperature increase.

  2. Fast optical detecting media based on semiconductor nanostructures for recording images obtained using charges of free photocarriers

    International Nuclear Information System (INIS)

    Kasherininov, P. G.; Tomasov, A. A.; Beregulin, E. V.

    2011-01-01

    Available published data on the properties of optical recording media based on semiconductor structures are reviewed. The principles of operation, structure, parameters, and the range of application for optical recording media based on MIS structures formed of photorefractive crystals with a thick layer of insulator and MIS structures with a liquid crystal as the insulator (the MIS LC modulators), as well as the effect of optical bistability in semiconductor structures (semiconductor MIS structures with nanodimensionally thin insulator (TI) layer, M(TI)S nanostructures). Special attention is paid to recording media based on the M(TI)S nanostructures promising for fast processing of highly informative images and to fabrication of optoelectronic correlators of images for noncoherent light.

  3. The oldest magnetic record in our solar system identified using nanometric imaging and numerical modeling.

    Science.gov (United States)

    Shah, Jay; Williams, Wyn; Almeida, Trevor P; Nagy, Lesleis; Muxworthy, Adrian R; Kovács, András; Valdez-Grijalva, Miguel A; Fabian, Karl; Russell, Sara S; Genge, Matthew J; Dunin-Borkowski, Rafal E

    2018-03-21

    Recordings of magnetic fields, thought to be crucial to our solar system's rapid accretion, are potentially retained in unaltered nanometric low-Ni kamacite (~ metallic Fe) grains encased within dusty olivine crystals, found in the chondrules of unequilibrated chondrites. However, most of these kamacite grains are magnetically non-uniform, so their ability to retain four-billion-year-old magnetic recordings cannot be estimated by previous theories, which assume only uniform magnetization. Here, we demonstrate that non-uniformly magnetized nanometric kamacite grains are stable over solar system timescales and likely the primary carrier of remanence in dusty olivine. By performing in-situ temperature-dependent nanometric magnetic measurements using off-axis electron holography, we demonstrate the thermal stability of multi-vortex kamacite grains from the chondritic Bishunpur meteorite. Combined with numerical micromagnetic modeling, we determine the stability of the magnetization of these grains. Our study shows that dusty olivine kamacite grains are capable of retaining magnetic recordings from the accreting solar system.

  4. Characterisation of human embryonic stem cells conditioning media by 1H-nuclear magnetic resonance spectroscopy.

    Directory of Open Access Journals (Sweden)

    David A MacIntyre

    Full Text Available BACKGROUND: Cell culture media conditioned by human foreskin fibroblasts (HFFs provide a complex supplement of protein and metabolic factors that support in vitro proliferation of human embryonic stem cells (hESCs. However, the conditioning process is variable with different media batches often exhibiting differing capacities to maintain hESCs in culture. While recent studies have examined the protein complement of conditioned culture media, detailed information regarding the metabolic component of this media is lacking. METHODOLOGY/PRINCIPAL FINDINGS: Using a (1H-Nuclear Magnetic Resonance ((1H-NMR metabonomics approach, 32 metabolites and small compounds were identified and quantified in media conditioned by passage 11 HFFs (CMp11. A number of metabolites were secreted by HFFs with significantly higher concentration of lactate, alanine, and formate detected in CMp11 compared to non-conditioned media. In contrast, levels of tryptophan, folate and niacinamide were depleted in CMp11 indicating the utilisation of these metabolites by HFFs. Multivariate statistical analysis of the (1H-NMR data revealed marked age-related differences in the metabolic profile of CMp11 collected from HFFs every 24 h over 72 h. Additionally, the metabolic profile of CMp11 was altered following freezing at -20°C for 2 weeks. CM derived from passage 18 HFFs (CMp18 was found to be ineffective at supporting hESCs in an undifferentiated state beyond 5 days culture. Multivariate statistical comparison of CMp11 and CMp18 metabolic profiles enabled rapid and clear discrimination between the two media with CMp18 containing lower concentrations of lactate and alanine as well as higher concentrations of glucose and glutamine. CONCLUSIONS/SIGNIFICANCE: (1H-NMR-based metabonomics offers a rapid and accurate method of characterising hESC conditioning media and is a valuable tool for monitoring, controlling and optimising hESC culture media preparation.

  5. Tribochemistry of Ionic Liquid Lubricant on Magnetic Media

    Directory of Open Access Journals (Sweden)

    Hirofumi Kondo

    2012-01-01

    Full Text Available The newly synthesized perfluoropolyether (PFPE ionic liquid whose terminal group is an ammonium salt with a carboxylic acid has better frictional properties when compared to the conventional PFPEs. Stick-slip motion was not observed even for the smooth surface for the modified PFPE tape. The friction is almost independent of the PFPE structure, but depends on the amine structures. The ammonium salt being tightly anchored to the rubbing surface covers uniformly, which leads to better lubricity. The higher dispersive interaction of the hydrophobic group of the amine is endowed with a compensating friction reduction. Steric hindrance of the hydrophilic group causes a high friction. Based on these findings, a saturated long chain ammonium salt is the best selection. Moreover, the modified PFPEs are dissolved in alcohol and hexane, which makes practical use convenient without any environmental problems. These ionic lubricants invented around 1987 have been used for magnetic tapes for about a quarter century because of their good lubricity and are reviewed in this paper.

  6. Band gaps in periodically magnetized homogeneous anisotropic media

    Science.gov (United States)

    Merzlikin, A. M.; Levy, M.; Vinogradov, A. P.; Wu, Z.; Jalali, A. A.

    2010-11-01

    In [A. M. Merzlikin, A. P. Vinogradov, A. V. Dorofeenko, M. Inoue, M. Levy, A. B. Granovsky, Physica B 394 (2007) 277] it is shown that in anisotropic magnetophotonic crystal made of anisotropic dielectric layers and isotropic magneto-optical layers the magnetization leads to formation of additional band gaps (BG) inside the Brillouin zones. Due to the weakness of the magneto-optical effects the width of these BG is much smaller than that of usual BG forming on the boundaries of Brillouin zones. In the present communication we show that though the anisotropy suppresses magneto-optical effects. An anisotropic magnetophotonic crystal made of anisotropic dielectric layers and anisotropic magneto-optical; the width of additional BG may be much greater than the width of the usual Brillouin BG. Anisotropy tends to suppress Brillouin zone boundary band gap formation because the anisotropy suppresses magneto-optical properties, while degenerate band gap formation occurs around points of effective isotropy and is not suppressed.

  7. Changing atmospheric fallout of magnetic particles recorded in recent ombrotrophic peat sections.

    Science.gov (United States)

    Oldfield, F; Thompson, R; Barber, K E

    1978-02-10

    Magnetic measurements of ombrotrophic peat allow a reconstruction of changes in the past fallout of magnetic particles through the atmosphere. In recent peat profiles from three sites in Britain and Northern Ireland, a marked increase in saturated isothermal remanent magnetization of the peat is recorded in levels which can be shown to postdate the onset of the Industrial Revolution. Furthermore the spatial variation in contemporary isothermal remanent magnetization values is consistent with a recent industrial and urban origin for the bulk of the magnetic minerals present. Pre-Industrial Revolution values are between two and three orders of magnitude lower, suggesting that the natural cosmic and terrestrial sources previously cited for such material have been dominated in recent times by the products of human activity. Magnetic measurements provide a simple, rapid, and nondestructive method of monitoring and differentiating various types of particulate atmospheric fallout for both recent and preindustrial times.

  8. Artificial magnetism and left-handed media from dielectric rings and rods

    International Nuclear Information System (INIS)

    Jelinek, L; Marques, R

    2010-01-01

    It is shown that artificial magnetism with relatively large frequency bandwidth can be obtained from periodic arrangements of dielectric rings. Combined with dielectric rods, dielectric rings can provide 3D isotropic left-handed metamaterials which are an advantageous alternative to metallic split ring resonators (SRRs) and/or metallic wires when undetectability by low frequency external magnetic fields is desired. Furthermore it is shown that, unlike conventional SRRs, dielectric rings can also be combined with natural plasma-like media to obtain a left-handed metamaterial.

  9. Artificial magnetism and left-handed media from dielectric rings and rods

    Energy Technology Data Exchange (ETDEWEB)

    Jelinek, L [Department of Electromagnetic Field, Czech Technical University in Prague, 166 27-Prague (Czech Republic); Marques, R, E-mail: l_jelinek@us.e [Departamento de Electronica y Electromagnetismo, Universidad de Sevilla, 41012-Sevilla (Spain)

    2010-01-20

    It is shown that artificial magnetism with relatively large frequency bandwidth can be obtained from periodic arrangements of dielectric rings. Combined with dielectric rods, dielectric rings can provide 3D isotropic left-handed metamaterials which are an advantageous alternative to metallic split ring resonators (SRRs) and/or metallic wires when undetectability by low frequency external magnetic fields is desired. Furthermore it is shown that, unlike conventional SRRs, dielectric rings can also be combined with natural plasma-like media to obtain a left-handed metamaterial.

  10. Probing the energy barriers and magnetization reversal processes of nanoperforated membrane based percolated media

    International Nuclear Information System (INIS)

    Neu, V; Schultz, L; Schulze, C; Makarov, D; Albrecht, M; Faustini, M; Grosso, D; Lee, J; Kim, S-K; Suess, D

    2013-01-01

    Magnetization reversal processes in Co/Pt multilayers prepared on nanoperforated templates are probed by magnetization relaxation measurements. The signature of pinning controlled domain wall movement as expected for percolated media is identified. This contrasts with the nucleation-type reversal mechanism of a Co/Pt reference film prepared on a smooth substrate. A zero field energy barrier of 93k B T is determined by fluctuation field measurements and is elucidated by micromagnetic calculations using the nudged elastic band method. This value is sufficiently large to qualify the material as a promising percolated medium. (paper)

  11. On the hystheresis and the recording process in magneticmedia

    NARCIS (Netherlands)

    Cramer, H.A.J.

    1993-01-01

    The information densities in magnetic recording systems have been in- creased considerably over the last few decades. Much af the gain in the in- formation density can be ascribed ta the improvement af the magnetic prop- erties af the recording media. However, recording on a magnetic medium is a

  12. A study on utility of magnetic resonance imaging for female pelvic cavity using enteral MRI contrast media

    International Nuclear Information System (INIS)

    Kim, Ham Gyum

    1997-01-01

    For radiological test in soft tissue or neighboring part with same signal intensity, proper test method and equipment shall be selected as needed. In case of female pelvic cavity, ultrasonography or computed tomography alternatively used, but MRI can be more usefully applied to design treatment method or operation plan by improving the diagnostic accuracy and careful observation of lesion characteristics. Magnetic Resonance Imaging using recently developed Enteral MRI contrast media can acquire more diagnostic information than using only intravenous contrast media. Thus this study attempted to examine the utility of anatomic structure and diagnostic acquisition by imaging the female pelvic cavity using Enteral MRI contrast media. As a result of analyzing magnetic resonance imaging after administering Enteral MRI contrast media to pelvic cavity suspect patients, more diagnostic information media could be acquired than only using intravenous contrast. Especially, in the diagnosis of lesion position, shape, distinction from neighboring tissues it is thought that external Enteral MRI contrast media should be used

  13. Inter-track interference mitigation with two-dimensional variable equalizer for bit patterned media recording

    Directory of Open Access Journals (Sweden)

    Yao Wang

    2017-05-01

    Full Text Available The increased track density in bit patterned media recording (BPMR causes increased inter-track interference (ITI, which degrades the bit error rate (BER performance. In order to mitigate the effect of the ITI, signals from multiple tracks can be equalized by a 2D equalizer with 1D target. Usually, the 2D fixed equalizer coefficients are obtained by using a pseudo-random bit sequence (PRBS for training. In this study, a 2D variable equalizer is proposed, where various sets of 2D equalizer coefficients are predetermined and stored for different ITI patterns besides the usual PRBS training. For data detection, as the ITI patterns are unknown in the first global iteration, the main and adjacent tracks are equalized with the conventional 2D fixed equalizer, detected with Bahl-Cocke-Jelinek-Raviv (BCJR detector and decoded with low-density parity-check (LDPC decoder. Then using the estimated bit information from main and adjacent tracks, the ITI pattern for each island of the main track can be estimated and the corresponding 2D variable equalizers are used to better equalize the bits on the main track. This process is executed iteratively by feeding back the main track information. Simulation results indicate that for both single-track and two-track detection, the proposed 2D variable equalizer can achieve better BER and frame error rate (FER compared to that with the 2D fixed equalizer.

  14. Using Technology to Improve Cancer Care: Social Media, Wearables, and Electronic Health Records.

    Science.gov (United States)

    Fisch, Michael J; Chung, Arlene E; Accordino, Melissa K

    2016-01-01

    Digital engagement has become pervasive in the delivery of cancer care. Internet- and cellular phone-based tools and systems are allowing large groups of people to engage with each other and share information. Health systems and individual health professionals are adapting to this revolution in consumer and patient behavior by developing ways to incorporate the benefits of technology for the purpose of improving the quality of medical care. One example is the use of social media platforms by oncologists to foster interaction with each other and to participate with the lay public in dialogue about science, medicine, and cancer care. In addition, consumer devices and sensors (wearables) have provided a new, growing dimension of digital engagement and another layer of patient-generated health data to foster better care and research. Finally, electronic health records have become the new standard for oncology care delivery, bringing new opportunities to measure quality in real time and follow practice patterns, as well as new challenges as providers and patients seek ways to integrate this technology along with other forms of digital engagement to produce more satisfaction in the process of care along with measurably better outcomes.

  15. FY1995 study to create the high density magnetic recording devices by using an ultra clean sputtering process; 1995 nendo choseijo sputter process ni yoru chokomitsudo jiki kiroku device no sosei

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    It is important to control microstructure of thin film magnetic devices such as recording heads and media, in order to induce excellent magnetic properties. Since the impurities in the sputtering atmosphere is easily thought to affect strongly on the initial film growth, we will develop the highly purified sputtering atmosphere to establish a fabrication technology of ultra thin metallic films with desirable microstructure. A specialized multi-sputtering system which has extremely clean atmosphere (impurity level: 1/10000 compared to conventional systems) were realized by (a) decreasing out-gassing rate from vacuum chamber, pumping system, cathode, robot, etc. and (b) using ultra-clean processing gas. The base pressure was 8 x 10{sup -12} Torr (XHV) and the build-up rate was less than 1 x 10{sup -8} Torrl/sec. From the correlation between the microstructure and magnetic properties of a part of spin-valve GMR films, the guiding principle for the microstructural design were clarified to induce the exchange coupling effectively at the ferro/antiferromagnetic interface and to enhance the GMR effect at the magnetic/non-magnetic interface. The mechanism of' Cr segregation on the grain boundaries was clarified, in thin film media deposited under ultra clean sputtering process. The material specification of the magnetic ultra thin film media for high density recording with low media noise were designed from view of the thermal agitation. (NEDO)

  16. Simultaneous transcranial magnetic stimulation and single neuron recording in alert non-human primates

    OpenAIRE

    Mueller, Jerel K.; Grigsby, Erinn M.; Prevosto, Vincent; Petraglia, Frank W.; Rao, Hrishikesh; Deng, Zhi-De; Peterchev, Angel V.; Sommer, Marc A.; Egner, Tobias; Platt, Michael L.; Grill, Warren M.

    2014-01-01

    Transcranial magnetic stimulation (TMS) is a widely used, noninvasive method for stimulating nervous tissue, yet its mechanisms of effect are poorly understood. Here we report novel methods for studying the influence of TMS on single neurons in the brain of alert non-human primates. We designed a TMS coil that focuses its effect near the tip of a recording electrode and recording electronics that enable direct acquisition of neuronal signals at the site of peak stimulus strength minimally per...

  17. NUCLEAR-MAGNETIC MINI-RELAXOMETER FOR LIQUID AND VISCOUS MEDIA CONTROL

    Directory of Open Access Journals (Sweden)

    V. V. Davydov

    2015-01-01

    Full Text Available The paper deals with a new method for registration of nuclear magnetic resonance signal of small volume liquid and viscous media being studied (0.5 ml in a weak magnetic field (0.06 –0.08 T, and measuring of longitudinal T1 and transverse T2 relaxation constants. A new construction of NMR mini-relaxometer magnetic system is developed for registration of NMR signal. The nonuniformity of a magnetic field in a pole where registration coil is located is 0,410–3 sm–1 (the induction is В0 = 0.079 T. An electrical circuit of autodyne receiver (weak fluctuations generator has been developed with usage of low noise differential amplifier and NMR signal operating and control scheme (based on microcontroller STM32 for measuring of relaxation constants of liquid and viscous media in automatic operating mode. New technical decisions made it possible to improve relaxometer response time and dynamic range of measurements for relaxation constants T1 and T2 in comparison with small sized nuclear-magnetic spectrometer developed by the authors earlier (with accuracy characteristics conservation. The developed schemes for self-tuning of registration frequency, generating amplitude of magnetic field H1 in registration coil, and amplitude and frequency of modulating field provide measuring of T1 and T2 with error less than 0.5 % and signal to noise ratio about 1.2 in temperature range from 3 to 400 C. A new construction of mini-relaxometer reduced the weight of the device to 4 kg (with independent supply unit and increased transportability and operating convenience.

  18. Measurement of radiation induced transients in hybrid microcircuits by magnetic thin film sensor/recorders

    International Nuclear Information System (INIS)

    Hsieh, E.J.; Vindelov, K.E.; Brown, T.G.; Miller, D.E.

    1976-01-01

    Magnetic thin film transient current sensor/recorders were modified to make two types of nuclear test measurements, transient currents in hybrid microcircuits and internal electromagnetic pulse (IEMP) fields. The measurements were made possible by the invention of split-domain sensor/recorders which can measure bilateral currents and can be reset and readout on location. The sensor/recorders were used in two underground nuclear tests and numerous calibration tests in radiation-simulation machines. The data showed that the nuclear environment had negligible effect on the sensor/recorder's operation and the recorded informations on the sensor/recorders were the signals intended to be monitored. Also, the experimental data agreed with the theoretical analysis in controlled experiments. The data were examined first by on location readout with a magnetic tape viewer and later by Kerr magneto-optic readout in the laboratory. To translate the data into current readings, we reconstructed facsimile data (on each of the sensor/recorders) in the laboratory by current pulses with the same pulse width as the radiation event. An additional check on the accuracy of the data was made by using both the sensor/recorder and the conventional pickup-oscilloscope-camera technique to monitor the same current lead in a simulated radiation environment. Over five runs were made, and the agreement among the two measurement methods was within 25%. The data collectively implied that the measurements were reliable and dependable

  19. Electromagnetic momentum in magnetic media and the Abraham-Minkowski controversy

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, J L [Departamento de Fisica, Division de Ciencias Basicas e Ingenieria, Universidad Autonoma Metropolitana, Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, Apartado Postal 21-463, Mexico DF, 04000 (Mexico); Campos, I [Departamento de Fisica, Facultad de Ciencias, Universidad Nacional Autonoma de Mexico, Apartado Postal 21-463, Mexico DF, 04000 (Mexico); Lopez-Marino, M A, E-mail: jlj@xanum.uam.mx, E-mail: iecampos@prodigy.net.mx, E-mail: malm@itesm.mx [Departamento de Ingenieria, Tecnologico de Monterrey, Campus Central de Veracruz, Av. E. Garza Sada 1, Apartado Postal 314, Cordoba, Veracruz, 94500 (Mexico)

    2011-05-15

    We explore the consequences of a force density, - (1)/c ({partial_derivative}M)/{partial_derivative}t x E, studied by some authors, for the device designed by Lai (1980 Am. J. Phys. 48 658) to analyse which definition of electromagnetic momentum density, either Minkowski's or Abraham's, is consistent with mechanical torques that arise from the change in time of a magnetic field, which produces an induced electric field that acts on free and polarization charges. It is found that Minkowski's definition is consistent with the mechanical torques associated with free charges, while Abraham's is consistent with mechanical torques associated with both free and polarization charges. We show that with this new force density Lai's work (1980 Am. J. Phys. 48 658) can be extended to include magnetic media. The results are consistent with Abraham's definition of electromagnetic momentum density, extending in this way its usefulness to magnetic media.

  20. Small-scale instrumentation for nuclear magnetic resonance of porous media

    International Nuclear Information System (INIS)

    Bluemich, Bernhard; Casanova, Federico; Dabrowski, Martin; Danieli, Ernesto; Haber, Agnes; Van Landeghem, Maxime; Haber-Pohlmeier, Sabina; Olaru, Alexandra; Perlo, Juan; Sucre, Oscar; Evertz, Loribeth

    2011-01-01

    The investigation of fluids confined to porous media is the oldest topic of investigation with small-scale nuclear magnetic resonance (NMR) instruments, as such instruments are mobile and can be moved to the site of the object, such as the borehole of an oil well. While the analysis was originally restricted by the inferior homogeneity of the employed magnets to relaxation measurements, today, portable magnets are available for all types of NMR measurements concerning relaxometry, imaging and spectroscopy in two types of geometries. These geometries refer to closed magnets that surround the sample and open magnets, which are brought close to the object for measurement. The current state of the art of portable, small-scale NMR instruments is reviewed and recent applications of such instruments are featured. These include the porosity analysis and description of diesel particulate filters, the determination of the moisture content in walls from gray concrete, new approaches to analyze the pore space and moisture migration in soil, and the constitutional analysis of the mortar base of ancient wall paintings.

  1. Observed periodicities and the spectrum of field variations in Holocene magnetic records

    DEFF Research Database (Denmark)

    Panovska, S.; Finlay, Chris; Hirt, A.M.

    2013-01-01

    , globally observed, periods. Rather we find a continuous broadband spectrum, with a slope corresponding to a power law with exponent of -2.3 ± 0.6 for the period range between 300 and 4000 yr. This is consistent with the hypothesis that chaotic convection in the outer core drives the majority of secular......In order to understand mechanisms that maintain and drive the evolution of the Earth's magnetic field, a characterization of its behavior on time scales of centuries to millennia is required. We have conducted a search for periodicities in Holocene sediment magnetic records, by applying three...

  2. Feature extraction for magnetic domain images of magneto-optical recording films using gradient feature segmentation

    International Nuclear Information System (INIS)

    Quanqing, Zhu.; Xinsai, Wang; Xuecheng, Zou; Haihua, Li; Xiaofei, Yang

    2002-01-01

    In this paper, we present a method to realize feature extraction on low contrast magnetic domain images of magneto-optical recording films. The method is based on the following three steps: first, Lee-filtering method is adopted to realize pre-filtering and noise reduction; this is followed by gradient feature segmentation, which separates the object area from the background area; finally the common linking method is adopted and the characteristic parameters of magnetic domain are calculated. We describe these steps with particular emphasis on the gradient feature segmentation. The results show that this method has advantages over other traditional ones for feature extraction of low contrast images

  3. LDPC code decoding adapted to the precoded partial response magnetic recording channels

    International Nuclear Information System (INIS)

    Lee, Jun; Kim, Kyuyong; Lee, Jaejin; Yang, Gijoo

    2004-01-01

    We propose a signal processing technique using LDPC (low-density parity-check) code instead of PRML (partial response maximum likelihood) system for the longitudinal magnetic recording channel. The scheme is designed by the precoder admitting level detection at the receiver-end and modifying the likelihood function for LDPC code decoding. The scheme can be collaborated with other decoder for turbo-like systems. The proposed algorithm can contribute to improve the performance of the conventional turbo-like systems

  4. LDPC code decoding adapted to the precoded partial response magnetic recording channels

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun E-mail: leejun28@sait.samsung.co.kr; Kim, Kyuyong; Lee, Jaejin; Yang, Gijoo

    2004-05-01

    We propose a signal processing technique using LDPC (low-density parity-check) code instead of PRML (partial response maximum likelihood) system for the longitudinal magnetic recording channel. The scheme is designed by the precoder admitting level detection at the receiver-end and modifying the likelihood function for LDPC code decoding. The scheme can be collaborated with other decoder for turbo-like systems. The proposed algorithm can contribute to improve the performance of the conventional turbo-like systems.

  5. Extracting Visual Evoked Potentials from EEG Data Recorded During fMRI-guided Transcranial Magnetic Stimulation

    OpenAIRE

    Sadeh, Boaz; Yovel, Galit

    2014-01-01

    Transcranial Magnetic Stimulation (TMS) is an effective method for establishing a causal link between a cortical area and cognitive/neurophysiological effects. Specifically, by creating a transient interference with the normal activity of a target region and measuring changes in an electrophysiological signal, we can establish a causal link between the stimulated brain area or network and the electrophysiological signal that we record. If target brain areas are functionally defined with prior...

  6. Experimental study on heat transfer enhancement of laminar ferrofluid flow in horizontal tube partially filled porous media under fixed parallel magnet bars

    Energy Technology Data Exchange (ETDEWEB)

    Sheikhnejad, Yahya; Hosseini, Reza, E-mail: hoseinir@aut.ac.ir; Saffar Avval, Majid

    2017-02-15

    In this study, steady state laminar ferroconvection through circular horizontal tube partially filled with porous media under constant heat flux is experimentally investigated. Transverse magnetic fields were applied on ferrofluid flow by two fixed parallel magnet bar positioned on a certain distance from beginning of the test section. The results show promising notable enhancement in heat transfer as a consequence of partially filled porous media and magnetic field, up to 2.2 and 1.4 fold enhancement were observed in heat transfer coefficient respectively. It was found that presence of both porous media and magnetic field simultaneously can highly improve heat transfer up to 2.4 fold. Porous media of course plays a major role in this configuration. Virtually, application of Magnetic field and porous media also insert higher pressure loss along the pipe which again porous media contribution is higher that magnetic field. - Highlights: • Porous media can improve the coefficient of heat transfer up to 2.2 fold. • Both porous media and Nano particles have undesired pressure drop effect. • Application of both porous media and magnetic field in ferrofluid flow will result in significant enhancement in heat transfer up to 2.4 fold. • Magnet bar effect is mainly restricted to approximately one fourth of the test section. • Diluted Ferrofluids 2%, results in over 1.4 fold enhancement in heat transfer coefficient.

  7. Treatment of Cerenkov radiation from electric and magnetic charges in dispersive and dissipative media

    International Nuclear Information System (INIS)

    Saffouri, M.H.

    1982-07-01

    A rigorous treatment of the problem of Cerenkov radiation from fast moving electric and magnetic charges is presented. This is based on the rigorous solution of Maxwell's equations in a general dispersive medium possessing dielectric and magnetic properties and with, and without, dissipation. It is shown that the fields are completely determined by one scalar function. Expressions for the exact fields are obtained. From the asymptotic fields all the relevant properties of Cerenkov radiation are reproduced. In particular, it is shown that in the absence of dissipation the energy in each mode travels with the phase velocity of that mode. For a dissipative medium the electric field develops a longitudinal component and the energy propagates at an angle to the phase velocity. Application to the case of a Tachyon shows that it must emit Cerenkov radiation in vacuum. An estimate is given for the resulting linear density of emitted radiation. Finally, two suggestions are made for the experimental detection of magnetic charges and electric dipole moments of elementary particles based upon the Cerenkov radiation which they would emit in dispersive media. (author)

  8. Cross-validation of independent ultra-low-frequency magnetic recording systems for active fault studies

    Science.gov (United States)

    Wang, Can; Bin, Chen; Christman, Lilianna E.; Glen, Jonathan M. G.; Klemperer, Simon L.; McPhee, Darcy K.; Kappler, Karl N.; Bleier, Tom E.; Dunson, J. Clark

    2018-04-01

    When working with ultra-low-frequency (ULF) magnetic datasets, as with most geophysical time-series data, it is important to be able to distinguish between cultural signals, internal instrument noise, and natural external signals with their induced telluric fields. This distinction is commonly attempted using simultaneously recorded data from a spatially remote reference site. Here, instead, we compared data recorded by two systems with different instrumental characteristics at the same location over the same time period. We collocated two independent ULF magnetic systems, one from the QuakeFinder network and the other from the United States Geological Survey (USGS)-Stanford network, in order to cross-compare their data, characterize data reproducibility, and characterize signal origin. In addition, we used simultaneous measurements at a remote geomagnetic observatory to distinguish global atmospheric signals from local cultural signals. We demonstrated that the QuakeFinder and USGS-Stanford systems have excellent coherence, despite their different sensors and digitizers. Rare instances of isolated signals recorded by only one system or only one sensor indicate that caution is needed when attributing specific recorded signal features to specific origins.[Figure not available: see fulltext.

  9. Use of contrast media in computed tomography and magnetic resonance imaging in horses: Techniques, adverse events and opportunities.

    Science.gov (United States)

    Nelson, B B; Goodrich, L R; Barrett, M F; Grinstaff, M W; Kawcak, C E

    2017-07-01

    The use of contrast media in computed tomography (CT) and magnetic resonance imaging (MRI) is increasing in horses. These contrast-enhanced imaging techniques provide improved tissue delineation and evaluation, thereby expanding diagnostic capabilities. While generally considered safe, not all contrast media exhibit the same safety profiles. The safety of contrast media use and descriptions of adverse events occurring in horses are sparsely reported. This review summarises the reported evidence of contrast media use and adverse events that occur in horses, with added contribution from other veterinary species and studies in man for comparison. This comprehensive data set empowers equine clinicians to develop use and monitoring strategies when working with contrast media. Finally, it summarises the current state-of-the-art and highlights the potential applications of contrast-enhanced CT and MRI for assessment of diseased or injured equine tissues, as well as (patho)physiological processes. © 2017 EVJ Ltd.

  10. Influence of Terrestrial Weathering on the Magnetic Record of a LL Chondrite

    Science.gov (United States)

    Kohout, T.; Kletetschka, G.; Wasilewski, P.

    2001-12-01

    The origin of our solar system may have been accompanied by transient energetic events capable of magnetizing the materials from which the solid bodies in the solar system formed. The magnetic field associated with some of some of these events should have been recorded by the magnetic mineralogy contained within meteorites. To extract this information from meteorites many noise components must be carefully eliminated. The fusion crust has long been established as restricted to a thin layer on the surface of meteorite. Magnetic screening of the fusion crust that relates to Murchison meteorite indicates that during the entry and landing at least 6 mm thick layer is affected by terrestrial TRM acquisition. Many of the meteorite finds have long term residence in the terrestrial oxidized environment. This weathering is the subject of this study. The meteorite in question landed in the Libya stony desert and has obvious surface weathering that can be referred to as desert varnish. The consequent iron oxide mineralization introduced very stable origin of very stable chemical remanent magnetization. The magnetic remanence in fragments without the desert varnish is between 20 - 50 % of the oxidized ones. The orientation of this CRM appears to be random indicating that the sample may have rotated during the long period of aeolian transport and varnish formation. Magnetization of the white matrix samples (20 - 50 % of weathered ones) is thermally more stable and also randomly oriented. The range of NRM/SIRM values for both mineralogies varies between 10-2 and 10-3. Acknowledgements: This work would not be possible without help of following people: Jakub Haloda, Petr Jakes, Marcela Bukovanska, Petr Pruner, Vladimir Kohout, Libuse Kohoutova, Vladimir Kohout, Olga Kohoutova.

  11. Simultaneous transcranial magnetic stimulation and single-neuron recording in alert non-human primates.

    Science.gov (United States)

    Mueller, Jerel K; Grigsby, Erinn M; Prevosto, Vincent; Petraglia, Frank W; Rao, Hrishikesh; Deng, Zhi-De; Peterchev, Angel V; Sommer, Marc A; Egner, Tobias; Platt, Michael L; Grill, Warren M

    2014-08-01

    Transcranial magnetic stimulation (TMS) is a widely used, noninvasive method for stimulating nervous tissue, yet its mechanisms of effect are poorly understood. Here we report new methods for studying the influence of TMS on single neurons in the brain of alert non-human primates. We designed a TMS coil that focuses its effect near the tip of a recording electrode and recording electronics that enable direct acquisition of neuronal signals at the site of peak stimulus strength minimally perturbed by stimulation artifact in awake monkeys (Macaca mulatta). We recorded action potentials within ∼1 ms after 0.4-ms TMS pulses and observed changes in activity that differed significantly for active stimulation as compared with sham stimulation. This methodology is compatible with standard equipment in primate laboratories, allowing easy implementation. Application of these tools will facilitate the refinement of next generation TMS devices, experiments and treatment protocols.

  12. Simultaneous transcranial magnetic stimulation and single neuron recording in alert non-human primates

    Science.gov (United States)

    Mueller, Jerel K.; Grigsby, Erinn M.; Prevosto, Vincent; Petraglia, Frank W.; Rao, Hrishikesh; Deng, Zhi-De; Peterchev, Angel V.; Sommer, Marc A.; Egner, Tobias; Platt, Michael L.; Grill, Warren M.

    2014-01-01

    Transcranial magnetic stimulation (TMS) is a widely used, noninvasive method for stimulating nervous tissue, yet its mechanisms of effect are poorly understood. Here we report novel methods for studying the influence of TMS on single neurons in the brain of alert non-human primates. We designed a TMS coil that focuses its effect near the tip of a recording electrode and recording electronics that enable direct acquisition of neuronal signals at the site of peak stimulus strength minimally perturbed by stimulation artifact in intact, awake monkeys (Macaca mulatta). We recorded action potentials within ~1 ms after 0.4 ms TMS pulses and observed changes in activity that differed significantly for active stimulation as compared to sham stimulation. The methodology is compatible with standard equipment in primate laboratories, allowing for easy implementation. Application of these new tools will facilitate the refinement of next generation TMS devices, experiments, and treatment protocols. PMID:24974797

  13. Recent advances in recording electrophysiological data simultaneously with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Laufs, H. [Univ Frankfurt, Zentrum Neurol and Neurochirurg, Neurol Klin, D-60590 Frankfurt (Germany); Laufs, H. [Univ Frankfurt, Dept Neurol, D-60590 Frankfurt (Germany); Laufs, H. [Univ Frankfurt, Brain Imaging Ctr, D-60590 Frankfurt (Germany); Laufs, H.; Carmichael, D.W. [UCL, Inst Neurol, Dept Clin and Expt Epilepsy, London (United Kingdom); Daunizeau, J. [Wellcome Trust Ctr Neuroimaging, London (United Kingdom); Kleinschmidt, A. [INSERM, Unite 562, F-91191 Gif SurYvette (France); Kleinschmidt, A. [CEA, DSV, I2BM, NeuroSpin, F-91191 Gif Sur Yvette (France); Kleinschmidt, A. [Univ Paris 11, F-91405 Orsay (France)

    2008-07-01

    Simultaneous recording of brain activity by different neuro-physiological modalities can yield insights that reach beyond those obtained by each technique individually, even when compared to those from the post-hoc integration of results from each technique recorded sequentially. Success in the endeavour of real-time multimodal experiments requires special hardware and software as well as purpose-tailored experimental design and analysis strategies. Here,we review the key methodological issues in recording electrophysiological data in humans simultaneously with magnetic resonance imaging (MRI), focusing on recent technical and analytical advances in the field. Examples are derived from simultaneous electro-encephalography (EEG) and electromyography (EMG) during functional MRI in cognitive and systems neuroscience as well as in clinical neurology, in particular in epilepsy and movement disorders. We conclude with an outlook on current and future efforts to achieve true integration of electrical and haemodynamic measures of neuronal activity using data fusion models. (authors)

  14. Variational principles for the static electric and magnetic polarizabilities of anisotropic media with perfect electric conductor inclusions

    International Nuclear Information System (INIS)

    Sjoeberg, Daniel

    2009-01-01

    We present four variational principles for the electric and magnetic polarizabilities for a structure consisting of anisotropic media with perfect electric conductor (PEC) inclusions. From these principles, we derive monotonicity results and upper and lower bounds on the electric and magnetic polarizabilities. When computing the polarizabilities numerically, the bounds can be used as error bounds. The variational principles demonstrate important differences between electrostatics and magnetostatics when PEC bodies are present.

  15. Self-Tracking, Social Media and Personal Health Records for Patient Empowered Self-Care. Contribution of the IMIA Social Media Working Group.

    Science.gov (United States)

    Paton, C; Hansen, M; Fernandez-Luque, L; Lau, A Y S

    2012-01-01

    This paper explores the range of self-tracking devices and social media platforms used by the self-tracking community, and examines the implications of widespread adoption of these tools for scientific progress in health informatics. A literature review was performed to investigate the use of social media and self-tracking technologies in the health sector. An environmental scan identified a range of products and services which were used to exemplify three levels of self-tracking: self-experimentation, social sharing of data and patient controlled electronic health records. There appears to be an increase in the use of self-tracking tools, particularly in the health and fitness sector, but also used in the management of chronic diseases. Evidence of efficacy and effectiveness is limited to date, primarily due to the health and fitness focus of current solutions as opposed to their use in disease management. Several key technologies are converging to produce a trend of increased personal health surveillance and monitoring, social connectedness and sharing, and integration of regional and national health information systems. These trends are enabling new applications of scientific techniques, from personal experimentation to e-epidemiology, as data gathered by individuals are aggregated and shared across increasingly connected healthcare networks. These trends also raise significant new ethical and scientific issues that will need to be addressed, both by health informatics researchers and the communities of self-trackers themselves.

  16. Thermal effects on transducer material for heat assisted magnetic recording application

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Rong, E-mail: Ji-Rong@dsi.a-star.edu.sg; Xu, Baoxi; Cen, Zhanhong; Ying, Ji Feng; Toh, Yeow Teck [Data Storage Institute, Agency for Science, Technology and Research (A-STAR), 5 Engineering Drive 1, Singapore 117608 (Singapore)

    2015-05-07

    Heat Assisted Magnetic Recording (HAMR) is a promising technology for next generation hard disk drives with significantly increased data recording capacities. In HAMR, an optical near-field transducer (NFT) is used to concentrate laser energy on a magnetic recording medium to fulfill the heat assist function. The key components of a NFT are transducer material, cladding material, and adhesion material between the cladding and the transducer materials. Since transducer materials and cladding materials have been widely reported, this paper focuses on the adhesion materials between the Au transducer and the Al{sub 2}O{sub 3} cladding material. A comparative study for two kinds of adhesion material, Ta and Cr, has been conducted. We found that Ta provides better thermal stability to the whole transducer than Cr. This is because after thermal annealing, chromium forms oxide material at interfaces and chromium atoms diffuse remarkably into the Au layer and react with Au to form Au alloy. This study also provides insights on the selection of adhesion material for HAMR transducer.

  17. Investigation of electromagnetic interference effects by ESD simulator on test parameters of tunneling magnetic recording heads

    Energy Technology Data Exchange (ETDEWEB)

    Kruesubthaworn, A., E-mail: anankr@kku.ac.th [KKU-Seagate Cooperation Research Laboratory, Department of Electrical Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Khunkitti, P.; Siritaratiwat, A.; Kaewrawang, A. [KKU-Seagate Cooperation Research Laboratory, Department of Electrical Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Mewes, T.; Mewes, C.K.A. [Department of Physics and Astronomy, MINT Center, University of Alabama, Tuscaloosa, AL 35487 (United States)

    2017-01-01

    Electrostatic discharge (ESD) has been an important issue in the manufacturing processes of hard disk drive. It can also generate electromagnetic interference (EMI) which could possibly damage magnetic recording heads. The aims of this work are to measure the EMI from ESD events and to examine the effects of EMI on the heads. The discharge current and the EMI generated by an ESD simulator were experimentally measured. Also, the EMI was applied to the heads to determine if this can cause changes of head parameters. Our results show that the discharge current waveform is consistent with the theoretical waveform of the IEC ESD standard. Additionally, we found that the EMI applied due to ESD at distances greater than 2 cm does not have any significant effect on the head parameters. Hence, further detailed experiments are proposed to evaluate the EMI effects on recording head parameters in order to improve the measurement methodologies to prevent the degradation of the heads performance and to increase the robustness of the heads. - Highlights: • The electrostatic discharge (ESD) has been an important issue for the hard disk drive. • The electromagnetic interference (EMI) radiated by ESD IEC 61000-4-2 was focused. • Effects of the EMI on the magnetic recording head were examined. • The change of parameters of the writer and reader due to the EMI was measured. • The EMI could not cause any significant affectation on the writer and reader.

  18. A two-stage heating scheme for heat assisted magnetic recording

    Science.gov (United States)

    Xiong, Shaomin; Kim, Jeongmin; Wang, Yuan; Zhang, Xiang; Bogy, David

    2014-05-01

    Heat Assisted Magnetic Recording (HAMR) has been proposed to extend the storage areal density beyond 1 Tb/in.2 for the next generation magnetic storage. A near field transducer (NFT) is widely used in HAMR systems to locally heat the magnetic disk during the writing process. However, much of the laser power is absorbed around the NFT, which causes overheating of the NFT and reduces its reliability. In this work, a two-stage heating scheme is proposed to reduce the thermal load by separating the NFT heating process into two individual heating stages from an optical waveguide and a NFT, respectively. As the first stage, the optical waveguide is placed in front of the NFT and delivers part of laser energy directly onto the disk surface to heat it up to a peak temperature somewhat lower than the Curie temperature of the magnetic material. Then, the NFT works as the second heating stage to heat a smaller area inside the waveguide heated area further to reach the Curie point. The energy applied to the NFT in the second heating stage is reduced compared with a typical single stage NFT heating system. With this reduced thermal load to the NFT by the two-stage heating scheme, the lifetime of the NFT can be extended orders longer under the cyclic load condition.

  19. Tunable magnetization of infrared epsilon-near-zero media via field-effect modulation

    Science.gov (United States)

    Salary, Mohammad Mahdi; Mosallaei, Hossein

    2018-04-01

    In this letter, we demonstrate that field effect modulation enables electrical tuning of the effective permeability of epsilon-near-zero (ENZ) media at infrared frequencies. In particular, hexagonal silicon carbide (6H-SiC) is incorporated as an epsilon-near-zero host in a gated 6H-SiC/SiO2/Si heterostructure. The change in the applied voltage leads to a change in the carrier concentration of the accumulation layer formed at the interface of 6H-SiC and SiO2 which can alter the effective permeability of the heterostructure by virtue of the photonic doping effect. We will rigorously model and analyze the structure by linking charge transport and electromagnetic models. The presented mechanism allows for tuning the impedance and magnetization of ENZ materials in real-time while capturing extreme cases of epsilon-and-mu-near-zero and magnetic conductor. As such, it can be used for various applications such as real-time engineering of thermal emission, dynamic switching, reconfigurable tunneling, and holography.

  20. Ultra-low power transmitter for encoding non-MR signals in Magnetic Resonance (MR) recordings

    DEFF Research Database (Denmark)

    Petersen, Jan Raagaard; Pedersen, Jan Ole; Zhurbenko, Vitaliy

    collection of data from non-MRI sensors. The transmitter consumes only 1.3mW while transmitting 2.7µW at 120MHz with high frequency stability. The presented design is useful in low power applications requiring high frequency stability and is intended for wireless transmission of non-MR signal recordings......Advancing Magnetic Resonance Imaging (MRI) technology requires integration of the MRI scanners with sensors and systems for monitoring various non-MRI signals. In this paper, we present design and integration of a low power AM radio transmitter into a 3T MRI scanner, which can be used for efficient...

  1. Small angle neutron scattering measurements of magnetic cluster sizes in magnetic recorging disks

    CERN Document Server

    Toney, M

    2003-01-01

    We describe Small Angle Neutron Scattering measurements of the magnetic cluster size distributions for several longitudinal magnetic recording media. We find that the average magnetic cluster size is slightly larger than the average physical grain size, that there is a broad distribution of cluster sizes, and that the cluster size is inversely correlated to the media signal-to-noise ratio. These results show that intergranular magnetic coupling in these media is small and they provide empirical data for the cluster-size distribution that can be incorporated into models of magnetic recording.

  2. Consumable Process Development for Chemical Mechanical Planarization of Bit Patterned Media for Magnetic Storage Fabrication

    Science.gov (United States)

    Bonivel, Joseph T., Jr.

    2010-09-01

    As the superparamagnetic limit is reached, the magnetic storage industry looks to circumvent the barrier by implementing patterned media (PM) as a viable means to store and access data. Chemical mechanical polishing (CMP) is a semiconductor fabrication technique used to planarize surfaces and is investigated as a method to ensure that the PM is polished to surface roughness parameters that allow the magnetic read/write head to move seamlessly across the PM. Results from this research have implications in feasibility studies of utilizing CMP as the main planarization technique for PM fabrication. Benchmark data on the output parameters of the CMP process, for bit patterned media (BPM), based on the machine process parameters, pad properties, and slurry characteristics are optimized. The research was conducted in a systematic manner in which the optimized parameters for each phase are utilized in future phases. The optimum results from each of the phases provide an overall optimum characterization for BPM CMP. Results on the CMP machine input parameters indicate that for optimal surface roughness and material removal, low polish pressures and high velocities should be used on the BPM. Pad characteristics were monitored by non destructive technique and results indicate much faster deterioration of all padcharacteristics versus polish time of BPM when compared to IC CMP. The optimum pad for PM polishing was the IC 1400 dual layer Suba V pad with a shore hardness of 57, and a k-groove pattern. The final phase of polishing evaluated the slurry polishing properties and novel nanodiamond (ND) slurry was created and benchmarked on BPM. The resulting CMP output parameters were monitored and neither the ND slurry nor the thermally responsive polymer slurry performed better than the commercially available Cabot iCue slurry for MRR or surface roughness. Research results indicate CMP is a feasible planarization technique for PM fabrication, but successful implementation of CMP

  3. Extracting Visual Evoked Potentials from EEG Data Recorded During fMRI-guided Transcranial Magnetic Stimulation

    Science.gov (United States)

    Sadeh, Boaz; Yovel, Galit

    2014-01-01

    Transcranial Magnetic Stimulation (TMS) is an effective method for establishing a causal link between a cortical area and cognitive/neurophysiological effects. Specifically, by creating a transient interference with the normal activity of a target region and measuring changes in an electrophysiological signal, we can establish a causal link between the stimulated brain area or network and the electrophysiological signal that we record. If target brain areas are functionally defined with prior fMRI scan, TMS could be used to link the fMRI activations with evoked potentials recorded. However, conducting such experiments presents significant technical challenges given the high amplitude artifacts introduced into the EEG signal by the magnetic pulse, and the difficulty to successfully target areas that were functionally defined by fMRI. Here we describe a methodology for combining these three common tools: TMS, EEG, and fMRI. We explain how to guide the stimulator's coil to the desired target area using anatomical or functional MRI data, how to record EEG during concurrent TMS, how to design an ERP study suitable for EEG-TMS combination and how to extract reliable ERP from the recorded data. We will provide representative results from a previously published study, in which fMRI-guided TMS was used concurrently with EEG to show that the face-selective N1 and the body-selective N1 component of the ERP are associated with distinct neural networks in extrastriate cortex. This method allows us to combine the high spatial resolution of fMRI with the high temporal resolution of TMS and EEG and therefore obtain a comprehensive understanding of the neural basis of various cognitive processes. PMID:24893706

  4. Extracting visual evoked potentials from EEG data recorded during fMRI-guided transcranial magnetic stimulation.

    Science.gov (United States)

    Sadeh, Boaz; Yovel, Galit

    2014-05-12

    Transcranial Magnetic Stimulation (TMS) is an effective method for establishing a causal link between a cortical area and cognitive/neurophysiological effects. Specifically, by creating a transient interference with the normal activity of a target region and measuring changes in an electrophysiological signal, we can establish a causal link between the stimulated brain area or network and the electrophysiological signal that we record. If target brain areas are functionally defined with prior fMRI scan, TMS could be used to link the fMRI activations with evoked potentials recorded. However, conducting such experiments presents significant technical challenges given the high amplitude artifacts introduced into the EEG signal by the magnetic pulse, and the difficulty to successfully target areas that were functionally defined by fMRI. Here we describe a methodology for combining these three common tools: TMS, EEG, and fMRI. We explain how to guide the stimulator's coil to the desired target area using anatomical or functional MRI data, how to record EEG during concurrent TMS, how to design an ERP study suitable for EEG-TMS combination and how to extract reliable ERP from the recorded data. We will provide representative results from a previously published study, in which fMRI-guided TMS was used concurrently with EEG to show that the face-selective N1 and the body-selective N1 component of the ERP are associated with distinct neural networks in extrastriate cortex. This method allows us to combine the high spatial resolution of fMRI with the high temporal resolution of TMS and EEG and therefore obtain a comprehensive understanding of the neural basis of various cognitive processes.

  5. In Situ TEM Scratch Testing of Perpendicular Magnetic Recording Multilayers with a Novel MEMS Tribometer

    Science.gov (United States)

    Hintsala, Eric D.; Stauffer, Douglas D.; Oh, Yunje; Asif, S. A. Syed

    2017-01-01

    Utilizing a newly developed two-dimensional (2D) transducer designed for in situ transmission electron microscope (TEM) nanotribology, deformation mechanisms of a perpendicular magnetic recording film stack under scratch loading conditions were evaluated. These types of films are widely utilized in storage devices, and loss of data by grain reorientation in the recording layers is of interest. The observed deformation was characterized by a stick-slip mechanism, which was induced by a critical ratio of lateral to normal force regardless of normal force. At low applied normal forces, the diamond-like carbon (DLC) coating and asperities in the recording layer were removed during scratching, while, at higher applied forces, grain reorientation and debonding of the recording layer was observed. As the normal force and displacement were increased, work for stick-slip deformation and contact stress were found to increase based upon an Archard's Law analysis. These experiments also served as an initial case study demonstrating the capabilities of this new transducer.

  6. Recording visual evoked potentials and auditory evoked P300 at 9.4T static magnetic field.

    Science.gov (United States)

    Arrubla, Jorge; Neuner, Irene; Hahn, David; Boers, Frank; Shah, N Jon

    2013-01-01

    Simultaneous recording of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) has shown a number of advantages that make this multimodal technique superior to fMRI alone. The feasibility of recording EEG at ultra-high static magnetic field up to 9.4 T was recently demonstrated and promises to be implemented soon in fMRI studies at ultra high magnetic fields. Recording visual evoked potentials are expected to be amongst the most simple for simultaneous EEG/fMRI at ultra-high magnetic field due to the easy assessment of the visual cortex. Auditory evoked P300 measurements are of interest since it is believed that they represent the earliest stage of cognitive processing. In this study, we investigate the feasibility of recording visual evoked potentials and auditory evoked P300 in a 9.4 T static magnetic field. For this purpose, EEG data were recorded from 26 healthy volunteers inside a 9.4 T MR scanner using a 32-channel MR compatible EEG system. Visual stimulation and auditory oddball paradigm were presented in order to elicit evoked related potentials (ERP). Recordings made outside the scanner were performed using the same stimuli and EEG system for comparison purposes. We were able to retrieve visual P100 and auditory P300 evoked potentials at 9.4 T static magnetic field after correction of the ballistocardiogram artefact using independent component analysis. The latencies of the ERPs recorded at 9.4 T were not different from those recorded at 0 T. The amplitudes of ERPs were higher at 9.4 T when compared to recordings at 0 T. Nevertheless, it seems that the increased amplitudes of the ERPs are due to the effect of the ultra-high field on the EEG recording system rather than alteration in the intrinsic processes that generate the electrophysiological responses.

  7. 37 CFR 201.28 - Statements of Account for digital audio recording devices or media.

    Science.gov (United States)

    2010-07-01

    ... conjunction with an annual audit of the manufacturing or importing party's financial statements. (ii) The CPA... Certified Public Accountants. (5) Manufacturing or importing party refers to any person or entity that... general class of products made up of functionally equivalent digital audio recording products with...

  8. 76 FR 71079 - Records Schedules; Availability and Request for Comments

    Science.gov (United States)

    2011-11-16

    ... including documentation on ethics training and guidance received by staff. 25. Social Security... year Federal agencies create billions of records on paper, film, magnetic tape, and other media. To... include records proposed as permanent. The schedules listed in this notice are media neutral unless...

  9. The Forbidden World of Off the Record Negotiating for Successful Air Force Media Engagements

    Science.gov (United States)

    2012-02-15

    OTR conversations seem common, is neglecting to train PAOs on OTR techniques akin to asking them to join in a high-stakes poker game after only...Report Submitted to the Faculty Air War College In Partial Fulfillment of the Graduation Requirements 15 February 2012...information into news stories with the proper context—that sometimes is impossible under on-the-record constraints. Few public affairs professionals or

  10. Understanding generalized inversions of nuclear magnetic resonance transverse relaxation time in porous media

    Science.gov (United States)

    Mitchell, J.; Chandrasekera, T. C.

    2014-12-01

    The nuclear magnetic resonance transverse relaxation time T2, measured using the Carr-Purcell-Meiboom-Gill (CPMG) experiment, is a powerful method for obtaining unique information on liquids confined in porous media. Furthermore, T2 provides structural information on the porous material itself and has many applications in petrophysics, biophysics, and chemical engineering. Robust interpretation of T2 distributions demands appropriate processing of the measured data since T2 is influenced by diffusion through magnetic field inhomogeneities occurring at the pore scale, caused by the liquid/solid susceptibility contrast. Previously, we introduced a generic model for the diffusion exponent of the form -ant_e^k (where n is the number and te the temporal separation of spin echoes, and a is a composite diffusion parameter) in order to distinguish the influence of relaxation and diffusion in CPMG data. Here, we improve the analysis by introducing an automatic search for the optimum power k that best describes the diffusion behavior. This automated method is more efficient than the manual trial-and-error grid search adopted previously, and avoids variability through subjective judgments of experimentalists. Although our method does not avoid the inherent assumption that the diffusion exponent depends on a single k value, we show through simulation and experiment that it is robust in measurements of heterogeneous systems that violate this assumption. In this way, we obtain quantitative T2 distributions from complicated porous structures and demonstrate the analysis with examples of ceramics used for filtration and catalysis, and limestone of relevance to the construction and petroleum industries.

  11. A Stable Pentagonal Bipyramidal Dy(III) Single-Ion Magnet with a Record Magnetization Reversal Barrier over 1000 K.

    Science.gov (United States)

    Liu, Jiang; Chen, Yan-Cong; Liu, Jun-Liang; Vieru, Veacheslav; Ungur, Liviu; Jia, Jian-Hua; Chibotaru, Liviu F; Lan, Yanhua; Wernsdorfer, Wolfgang; Gao, Song; Chen, Xiao-Ming; Tong, Ming-Liang

    2016-04-27

    Single-molecule magnets (SMMs) with a large spin reversal barrier have been recognized to exhibit slow magnetic relaxation that can lead to a magnetic hysteresis loop. Synthesis of highly stable SMMs with both large energy barriers and significantly slow relaxation times is challenging. Here, we report two highly stable and neutral Dy(III) classical coordination compounds with pentagonal bipyramidal local geometry that exhibit SMM behavior. Weak intermolecular interactions in the undiluted single crystals are first observed for mononuclear lanthanide SMMs by micro-SQUID measurements. The investigation of magnetic relaxation reveals the thermally activated quantum tunneling of magnetization through the third excited Kramers doublet, owing to the increased axial magnetic anisotropy and weaker transverse magnetic anisotropy. As a result, pronounced magnetic hysteresis loops up to 14 K are observed, and the effective energy barrier (Ueff = 1025 K) for relaxation of magnetization reached a breakthrough among the SMMs.

  12. Modeling and Analysis of Magnetic Nanoparticles Injection in Water-Oil Two-Phase Flow in Porous Media under Magnetic Field Effect

    KAUST Repository

    El-Amin, Mohamed; Saad, Adel; Salama, Amgad; Sun, Shuyu

    2017-01-01

    In this paper, the magnetic nanoparticles are injected into a water-oil, two-phase system under the influence of an external permanent magnetic field. We lay down the mathematical model and provide a set of numerical exercises of hypothetical cases to show how an external magnetic field can influence the transport of nanoparticles in the proposed two-phase system in porous media. We treat the water-nanoparticles suspension as a miscible mixture, whereas it is immiscible with the oil phase. The magnetization properties, the density, and the viscosity of the ferrofluids are obtained based on mixture theory relationships. In the mathematical model, the phase pressure contains additional term to account for the extra pressures due to fluid magnetization effect and the magnetostrictive effect. As a proof of concept, the proposed model is applied on a countercurrent imbibition flow system in which both the displacing and the displaced fluids move in opposite directions. Physical variables, including waternanoparticles suspension saturation, nanoparticles concentration, and pore wall/throat concentrations of deposited nanoparticles, are investigated under the influence of the magnetic field. Two different locations of the magnet are studied numerically, and variations in permeability and porosity are considered.

  13. Modeling and Analysis of Magnetic Nanoparticles Injection in Water-Oil Two-Phase Flow in Porous Media under Magnetic Field Effect

    KAUST Repository

    El-Amin, Mohamed

    2017-08-28

    In this paper, the magnetic nanoparticles are injected into a water-oil, two-phase system under the influence of an external permanent magnetic field. We lay down the mathematical model and provide a set of numerical exercises of hypothetical cases to show how an external magnetic field can influence the transport of nanoparticles in the proposed two-phase system in porous media. We treat the water-nanoparticles suspension as a miscible mixture, whereas it is immiscible with the oil phase. The magnetization properties, the density, and the viscosity of the ferrofluids are obtained based on mixture theory relationships. In the mathematical model, the phase pressure contains additional term to account for the extra pressures due to fluid magnetization effect and the magnetostrictive effect. As a proof of concept, the proposed model is applied on a countercurrent imbibition flow system in which both the displacing and the displaced fluids move in opposite directions. Physical variables, including waternanoparticles suspension saturation, nanoparticles concentration, and pore wall/throat concentrations of deposited nanoparticles, are investigated under the influence of the magnetic field. Two different locations of the magnet are studied numerically, and variations in permeability and porosity are considered.

  14. Measuring adsorption, diffusion and flow in chemical engineering: applications of magnetic resonance to porous media

    International Nuclear Information System (INIS)

    Gladden, Lynn F; Mitchell, Jonathan

    2011-01-01

    Magnetic resonance (MR) techniques are increasingly used to improve our understanding of the multi-component, multi-phase processes encountered in chemical engineering. This review brings together many of the MR techniques used, and often developed specifically, to study chemical engineering systems and, in particular, processes occurring within porous media. Pulse sequences for relaxometry, pulsed field gradient measurements of diffusion, imaging and velocimetry measurements are described. Recent applications of these MR pulse sequences to microporous, mesoporous and macroporous structures are then reviewed. Considering the microporous and mesoporous systems, we focus attention on studies of rock cores, manufactured materials such as cement and gypsum plaster, and catalysts. When considering macroporous structures, the transport through packed beds of particles typical of fixed-bed catalytic reactors is reviewed; a brief overview of the increasing research interest in gas-solid fluidized beds is also presented. We highlight the field of sparse k-space sampling as an area that is in its infancy and suggest that, combined with Bayesian methods, it will offer new opportunities in both extending the application of high-field MR techniques to chemical engineering and increasing the range of measurements that can be carried out using low-field hardware.

  15. 75 FR 35853 - Privacy Act of 1974: Systems of Records

    Science.gov (United States)

    2010-06-23

    ... practices or possible regulatory compliance issues. 3. To conduct lawful relational searches or analysis or... stored in computerized databases. Records stored on other electronic media (e.g., magnetic disk, tape...

  16. Magnetic record of Mio-Pliocene red clay and Quaternary loess-paleosol sequence in the Chinese Loess Plateau

    Directory of Open Access Journals (Sweden)

    Yougui Song

    2018-02-01

    Full Text Available This article presents magnetic data of a 300-m-thick Mio-Pliocene red clay and Quaternary loess-paleosol sequence near Chaona town in the Central Chinese Loess Plateau. Detailed magnetostratigraphy shows that the aeolian red clay began to accumulate at ca. 8.1 Ma. Here, we presented a high-resolution rock magnetic data at 20–40 cm intervals within 4.5–8 ka span per sample of this section, which has been published in Song et al. (2014 [1] and (2017 [2]. The dataset including the following magnetic parameters: mass magnetic susceptibility (χ, frequency-dependent susceptibility (χfd, saturation magnetization (Ms, saturation remanent magnetization (Mrs, coercive force (Bc, remanent coercivity (Bcr, saturation isothermal remanent magnetization (SIRM and S-ratio. Magnetic susceptibility and hysteresis parameters were measured at Lanzhou University and Kyoto University, respectively. This data provides a high-resolution rock magnetic evidences for understanding East Asia Monsoon change, Asian interior aridification and tectonic effect of the uplift of the Tibetan Plateau since middle Miocene period. Keywords: Rock magnetic record, Late Miocene and Pliocene red clay, Quaternary loess-paleosol sequence, Chinese Loess Plateau

  17. Magnetism and rotation effect on surface waves in fibre-reinforced anisotropic general viscoelastic media of higher order

    Energy Technology Data Exchange (ETDEWEB)

    Abo-Dahab, S. M. [Taif University, Taif (Saudi Arabia); Abd-Alla, A. M. [SVU, Qena (Egypt); Khan, Aftab [Sohag University, Sohag (Egypt)

    2015-08-15

    The aim of this paper is to study the propagation of surface waves in a rotating fibre-reinforced viscoelastic media of higher order under the influence of magnetic field. The general surface wave speeds derived to study the effects of rotation and magnetic field on surface waves. Particular cases for Stoneley, Love and Rayleigh waves are also discussed and dispersion relation for the waves has been deduced. The results obtained in this investigation are more general in the sense that some earlier published results are obtained from our result as special cases. For order zero our results are well agreement to fibre-reinforced materials. Also by neglecting the reinforced elastic parameters, the results reduce to well known isotropic medium. It is observed that in a rotating medium the surface waves are dispersive. Also magnetic effects play a significant roll. It is observed that Love wave remain unaffected in a rotating medium but remain under the influence of magnetic field. Rayleigh waves are affected by rotation and magnetic field whereas Stoneley waves are independent of Maxwell stresses. It is also observed that, surface waves cannot propagate in a fast rotating medium or in the presence of magnetic field of high intensity. Numerical results for particular materials are given and illustrated graphically. The results indicate that the effect of rotation and magnetic field are very pronounced.

  18. Magnetism and rotation effect on surface waves in fibre-reinforced anisotropic general viscoelastic media of higher order

    International Nuclear Information System (INIS)

    Abo-Dahab, S. M.; Abd-Alla, A. M.; Khan, Aftab

    2015-01-01

    The aim of this paper is to study the propagation of surface waves in a rotating fibre-reinforced viscoelastic media of higher order under the influence of magnetic field. The general surface wave speeds derived to study the effects of rotation and magnetic field on surface waves. Particular cases for Stoneley, Love and Rayleigh waves are also discussed and dispersion relation for the waves has been deduced. The results obtained in this investigation are more general in the sense that some earlier published results are obtained from our result as special cases. For order zero our results are well agreement to fibre-reinforced materials. Also by neglecting the reinforced elastic parameters, the results reduce to well known isotropic medium. It is observed that in a rotating medium the surface waves are dispersive. Also magnetic effects play a significant roll. It is observed that Love wave remain unaffected in a rotating medium but remain under the influence of magnetic field. Rayleigh waves are affected by rotation and magnetic field whereas Stoneley waves are independent of Maxwell stresses. It is also observed that, surface waves cannot propagate in a fast rotating medium or in the presence of magnetic field of high intensity. Numerical results for particular materials are given and illustrated graphically. The results indicate that the effect of rotation and magnetic field are very pronounced.

  19. Hybrid Adaptive Filter development for the minimisation of transient fluctuations superimposed on electrotelluric field recordings mainly by magnetic storms

    Directory of Open Access Journals (Sweden)

    A. Konstantaras

    2006-01-01

    Full Text Available The method of Hybrid Adaptive Filtering (HAF aims to recover the recorded electric field signals from anomalies of magnetotelluric origin induced mainly by magnetic storms. An adaptive filter incorporating neuro-fuzzy technology has been developed to remove any significant distortions from the equivalent magnetic field signal, as retrieved from the original electric field signal by reversing the magnetotelluric method. Testing with further unseen data verifies the reliability of the model and demonstrates the effectiveness of the HAF method.

  20. The role of MFM signal in mark size measurement in probe-based magnetic recording on CoNi/Pt multilayers

    NARCIS (Netherlands)

    Zhang, Li; Bain, James A.; Zhu, Jian-Gang; Abelmann, Leon; Onoue, T.

    2007-01-01

    A method of heat-assisted magnetic recording (HAMR) potentially suitable for probe-based storage systems is characterized. Magnetic marks were formed by a scanning tunneling microscopy (STM)-based thermal magnetic mechanism on a perpendicular CoNi/Pt multilayered film. Magnetic force microscopy

  1. Heat-Assisted Magnetic Recording: Fundamental Limits to Inverse Electromagnetic Design

    Science.gov (United States)

    Bhargava, Samarth

    In this dissertation, we address the burgeoning fields of diffractive optics, metals-optics and plasmonics, and computational inverse problems in the engineering design of electromagnetic structures. We focus on the application of the optical nano-focusing system that will enable Heat-Assisted Magnetic Recording (HAMR), a higher density magnetic recording technology that will fulfill the exploding worldwide demand of digital data storage. The heart of HAMR is a system that focuses light to a nano- sub-diffraction-limit spot with an extremely high power density via an optical antenna. We approach this engineering problem by first discussing the fundamental limits of nano-focusing and the material limits for metal-optics and plasmonics. Then, we use efficient gradient-based optimization algorithms to computationally design shapes of 3D nanostructures that outperform human designs on the basis of mass-market product requirements. In 2014, the world manufactured ˜1 zettabyte (ZB), ie. 1 Billion terabytes (TBs), of data storage devices, including ˜560 million magnetic hard disk drives (HDDs). Global demand of storage will likely increase by 10x in the next 5-10 years, and manufacturing capacity cannot keep up with demand alone. We discuss the state-of-art HDD and why industry invented Heat-Assisted Magnetic Recording (HAMR) to overcome the data density limitations. HAMR leverages the temperature sensitivity of magnets, in which the coercivity suddenly and non-linearly falls at the Curie temperature. Data recording to high-density hard disks can be achieved by locally heating one bit of information while co-applying a magnetic field. The heating can be achieved by focusing 100 microW of light to a 30nm diameter spot on the hard disk. This is an enormous light intensity, roughly ˜100,000,000x the intensity of sunlight on the earth's surface! This power density is ˜1,000x the output of gold-coated tapered optical fibers used in Near-field Scanning Optical Microscopes

  2. Induced Electromagnetic Field by Seismic Waves in Stratified Media in Earth's Magnetic Field

    Science.gov (United States)

    Yamazaki, K.

    2017-12-01

    Seismic waves accompany electromagnetic (EM) variations because Earth's crust involves a variety of EM properties such as finite electrical conductivity and ion contents. If we can catch the EM variations just after the earthquake rupture, we will know the occurrence of earthquake before the arrival of seismic waves at observation point. However, quantitative aspects of EM variations arising from seismic waves have not sufficiently understood. Together with observational works, theoretical works have been made to simulate EM variations arising from seismic waves. The generation mechanisms of EM variations include electrokinetic effect (Pride, 1994), motional induction (Gao et al., 2014), piezo-electric effect (Ogawa and Utada, 2000), piezo-magnetic effect (Yamazaki, 2016), etc. It is widely accepted that the electrokinetic effect is the dominant mechanism. Theoretical calculation of EM variations assuming the electrokinetic effect roughly explains the observed EM variations accompanying with earthquake ground motions (e.g. Gao et al. 2016). However, there are a significant disagreement between observed and predicted EM variations. In the present study, I focus on the motional induction mechanism that possibly explain some parts of EM variations accompanying with seismic waves. A theoretical work on EM variations arising from the motional induction has been presented by Gao et al. (2014), but their work assumed uniform full-space medium. In contrast, the present work assumes stratified media which correctly incorporate the effect of the ground surface. I apply a calculating method developed in seismology (e.g. Kennett, 2013) and in EM studies (Haartsen and Pride, 1997), and derive a set of expressions describing the spatial-temporal variations of the EM field after the onset of rupture. The derived formula is used to calculate EM variations for actual earthquakes to compare the theoretical prediction to observed EM variations.

  3. 75 FR 9233 - Privacy Act of 1974; U.S. Immigration and Customs Enforcement-006 Intelligence Records System of...

    Science.gov (United States)

    2010-03-01

    ..., citizenship/immigration status, passport information, addresses, phone numbers, etc.); (2) Records of... magnetic disc, tape, digital media, and CD-ROM. RETRIEVABILITY: Records may be retrieved by personal...

  4. A minimum operating system based on the SM5300.01 magnetic tape recorder for the Micro-8 computer

    International Nuclear Information System (INIS)

    Kartashov, S.V.

    1987-01-01

    An operating system (OS) for microcomputers based on INTEL-8080, 8085 microprocessors oriented to use a magnetic tape recorder is described. This system comprises a tape-recorder manager and a file structure organization system (nucleus of OS), a symbol text editor, a macroassembler, an interactive disasembler and a program of communication with an EC-computer. The OS makes it possible to develop, debug, store and exploit the program written in INTEL-8085 assembly language

  5. Contrast Media for X-ray and Magnetic Resonance Imaging: Development, Current Status and Future Perspectives.

    Science.gov (United States)

    Frenzel, Thomas; Lawaczeck, Rüdiger; Taupitz, Matthias; Jost, Gregor; Lohrke, Jessica; Sieber, Martin A; Pietsch, Hubertus

    2015-09-01

    Over the last 120 years, the extensive advances in medical imaging allowed enhanced diagnosis and therapy of many diseases and thereby improved the quality of life of many patient generations. From the beginning, all technical solutions and imaging procedures were combined with dedicated pharmaceutical developments of contrast media, to further enhance the visualization of morphology and physiology. This symbiosis of imaging hardware and contrast media development was of high importance for the development of modern clinical radiology. Today, all available clinically approved contrast media fulfill the highest requirements for clinical safety and efficacy. All new concepts to increase the efficacy of contrast media have also to consider the high clinical safety standards and cost of goods of current marketed contrast media. Nevertheless, diagnostic imaging will contribute significantly to the progresses in medicine, and new contrast media developments are mandatory to address the medical needs of the future.

  6. MR-eyetracker: a new method for eye movement recording in functional magnetic resonance imaging.

    Science.gov (United States)

    Kimmig, H; Greenlee, M W; Huethe, F; Mergner, T

    1999-06-01

    We present a method for recording saccadic and pursuit eye movements in the magnetic resonance tomograph designed for visual functional magnetic resonance imaging (fMRI) experiments. To reliably classify brain areas as pursuit or saccade related it is important to carefully measure the actual eye movements. For this purpose, infrared light, created outside the scanner by light-emitting diodes (LEDs), is guided via optic fibers into the head coil and onto the eye of the subject. Two additional fiber optical cables pick up the light reflected by the iris. The illuminating and detecting cables are mounted in a plastic eyepiece that is manually lowered to the level of the eye. By means of differential amplification, we obtain a signal that covaries with the horizontal position of the eye. Calibration of eye position within the scanner yields an estimate of eye position with a resolution of 0.2 degrees at a sampling rate of 1000 Hz. Experiments are presented that employ echoplanar imaging with 12 image planes through visual, parietal and frontal cortex while subjects performed saccadic and pursuit eye movements. The distribution of BOLD (blood oxygen level dependent) responses is shown to depend on the type of eye movement performed. Our method yields high temporal and spatial resolution of the horizontal component of eye movements during fMRI scanning. Since the signal is purely optical, there is no interaction between the eye movement signals and the echoplanar images. This reasonably priced eye tracker can be used to control eye position and monitor eye movements during fMRI.

  7. Direct measurement of the field from a magnetic recording head using an InAs Hall sensor on a contact write/read tester

    International Nuclear Information System (INIS)

    Gokemeijer, N.J.; Clinton, T.W.; Crawford, T.M.; Johnson, Mark

    2005-01-01

    At 1 Tbit/in 2 areal density magnetic recording dimensions, reliable magnetic field metrology does not exist. One technique to map the spatial profile of the magnetic field of a write head is to use a contact read/write tester. A magnetic recording head is brought into contact with a Hall sensor, and is subsequently scanned with nm resolution. For a 300 nm track width longitudinal recording head, the magnetic field of the head was mapped. Measurements include the down track field gradient and cross-track field profile and the current-field transfer curve. These results suggest this technique offers a viable write field metrology

  8. Time-Resolved Records of Magnetic Activity on the Pallasite Parent Body and Psyche

    Science.gov (United States)

    Bryson, J. F. J.; Nichols, C. I. O.; Herrero-Albillos, J.; Kronast, F.; Kasama, T.; Alimadadi, H.; van der Laan, G.; Nimmo, F.; Harrison, R. J.

    2014-12-01

    Although many small bodies apparently generated dynamo fields in the early solar system, the nature and temporal evolution of these fields has remained enigmatic. Time-resolved records of the Earth's planetary field have been essential in understanding the dynamic history of our planet, and equivalent information from asteroids could provide a unique insight into the development of the solar system. Here we present time-resolved records of magnetic activity on the main-group pallasite parent body and (16) Psyche, obtained using newly-developed nanomagnetic imaging techniques. For the pallasite parent body, the inferred field direction remained relatively constant and the intensity was initially stable at ~100 μT before it decreased in two discrete steps down to 0 μT. We interpret this behaviour as due to vigorous dynamo activity driven by compositional convection in the core, ultimately transitioning from a dipolar to multipolar field as the inner core grew from the bottom-up. For Psyche (measured from IVA iron meteorites), the inferred field direction reversed, while the intensity remained stable at >50 μT. Psyche cooled rapidly as an unmantled core, although the resulting thermal convection alone cannot explain these observations. Instead, this behaviour required top-down core solidification, and is attributed either to compositional convection (if the core also solidified from the bottom-up) or convection generated directly by top-down solidification (e.g. Fe-snow). The mechanism governing convection in small body cores is an open question (due partly to uncertainties in the direction of core solidification), and these observations suggest that unconventional (i.e. not thermal) mechanisms acted in the early solar system. These mechanisms are very efficient at generating convection, implying a long-lasting and widespread epoch of dynamo activity among small bodies in the early solar system.

  9. High-resolution records of non-dipole variations in the intensity of the Earth's magnetic field

    NARCIS (Netherlands)

    de Groot, L.V.

    2013-01-01

    Our understanding of the short-term behavior of the Earth’s magnetic field is currently mainly hampered by a lack of high-resolution records of geomagnetic intensity variations that are well distributed over the globe and cover the same timespan. Over the past decades many efforts have been made to

  10. Patch-clamp recordings of rat neurons from acute brain slices of the somatosensory cortex during magnetic stimulation.

    Science.gov (United States)

    Pashut, Tamar; Magidov, Dafna; Ben-Porat, Hana; Wolfus, Shuki; Friedman, Alex; Perel, Eli; Lavidor, Michal; Bar-Gad, Izhar; Yeshurun, Yosef; Korngreen, Alon

    2014-01-01

    Although transcranial magnetic stimulation (TMS) is a popular tool for both basic research and clinical applications, its actions on nerve cells are only partially understood. We have previously predicted, using compartmental modeling, that magnetic stimulation of central nervous system neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. The simulations also predict that neurons with low current threshold are more susceptible to magnetic stimulation. Here we tested these theoretical predictions by combining in vitro patch-clamp recordings from rat brain slices with magnetic stimulation and compartmental modeling. In agreement with the modeling, our recordings demonstrate the dependence of magnetic stimulation-triggered action potentials on the type and state of the neuron and its orientation within the magnetic field. Our results suggest that the observed effects of TMS are deeply rooted in the biophysical properties of single neurons in the central nervous system and provide a framework both for interpreting existing TMS data and developing new simulation-based tools and therapies.

  11. Patch-clamp recordings of rat neurons from acute brain slices of the somatosensory cortex during magnetic stimulation

    Directory of Open Access Journals (Sweden)

    Tamar ePashut

    2014-06-01

    Full Text Available Although transcranial magnetic stimulation (TMS is a popular tool for both basic research and clinical applications, its actions on nerve cells are only partially understood. We have previously predicted, using compartmental modeling, that magnetic stimulation of central nervous system neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. The simulations also predict that neurons with low current threshold are more susceptible to magnetic stimulation. Here we tested these theoretical predictions by combining in vitro patch-clamp recordings from rat brain slices with magnetic stimulation and compartmental modeling. In agreement with the modeling, our recordings demonstrate the dependence of magnetic stimulation-triggered action potentials on the type and state of the neuron and its orientation within the magnetic field. Our results suggest that the observed effects of TMS are deeply rooted in the biophysical properties of single neurons in the central nervous system and provide a framework both for interpreting existing TMS data and developing new simulation-based tools and therapies.

  12. Asymmetry of magnetic motor evoked potentials recorded in calf muscles of the dominant and non-dominant lower extremity.

    Science.gov (United States)

    Olex-Zarychta, Dorota; Koprowski, Robert; Sobota, Grzegorz; Wróbel, Zygmunt

    2009-08-07

    The aim of the study was to determine the applicability of magnetic stimulation and magnetic motor evoked potentials (MEPs) in motor asymmetry studies by obtaining quantitative and qualitative measures of efferent activity during low intensity magnetic stimulation of the dominant and non-dominant lower extremities. Magnetic stimulation of the tibial nerve in the popliteal fossa was performed in 10 healthy male right-handed and right-footed young adults. Responses were recorded from the lateral head of the gastrocnemius muscles of the right and left lower extremities. Response characteristics (duration, onset latency, amplitude) were analyzed in relation to the functional dominance of the limbs and in relation to the direction of the current in the magnetic coil by use of the Wilcoxon pair sequence test. The CCW direction of coil current was related to reduced amplitudes of recorded MEPs. Greater amplitudes of evoked potentials were recorded in the non-dominant extremity, both in the CW and CCW coil current directions, with the statistical significance of this effect (p=0.005). No differences in duration of response were found in the CW current direction, while in CCW the time of the left-side response was prolonged (p=0.01). In the non-dominant extremity longer onset latencies were recorded in both current directions, but only for the CW direction the side asymmetries showed a statistical significance of p=0.005. In the dominant extremity the stimulation correlated with stronger paresthesias, especially using the CCW direction of coil current. The results indicate that low intensity magnetic stimulation may be useful in quantitative and qualitative research into the motor asymmetry.

  13. Diffusion processes in unsaturated porous media studied with nuclear magnetic resonance techniques

    International Nuclear Information System (INIS)

    Farrher, German David

    2006-01-01

    Unsaturated porous media form two-phase systems consisting of the liquid and its vapor. Molecular exchange between the two phases defines an effective diffusion coefficient which substantially deviates from the bulk value of the liquid. The objective of the present thesis is to study self-diffusion under such conditions by varying both the filling degree of the porous medium and the diffusion time. The main experimental tool was a combination of two different NMR field gradient diffusometry techniques. For comparison, diffusion in a porous medium was modeled with the aid of Monte Carlo simulations. The NMR diffusometry techniques under consideration were the pulsed gradient stimulated echo (PGStE) method, the fringe field stimulated echo (FFStE) method, and the magnetization grid rotating frame imaging (MAGROFI) method. As liquids, water and cyclohexane were chosen as representatives of polar and nonpolar species. The porous glasses examined were Vycor with a mean pore size of 4 nm and VitraPor 5, with a pore size ranging from 1 to 1.6 μm. Using a combination of the FFStE and the MAGROFI technique permits one to cover four decades of the diffusion time from 100 μs to 1 s. The time dependences acquired in this way were compared with Monte Carlo simulations of a model structure in a time window of eight decades, from 125 ps up to 12.5 ms. NMR microscopy of VitraPor5 partially filled with water or cyclohexane reveals heterogeneous distributions of the liquid on a length scale much longer than the pore dimension. As a consequence of the inhomogeneous filling degree, the effective transverse relaxation time varies, which in turn leads to NMR imaging contrasts. The NMR methods employed, that is, a combination of FFStE and MAGROFI diffusometry, provide effective diffusion coefficients not affected by spatial variations of the transverse relaxation time, in contrast to the PGStE method: The FFStE and MAGROFI techniques render the effective diffusion coefficient averaged

  14. Electron holography study of magnetization behavior in the writer pole of a perpendicular magnetic recording head by a 1 MV transmission electron microscope.

    Science.gov (United States)

    Hirata, Kei; Ishida, Yoichi; Akashi, Tetsuya; Shindo, Daisuke; Tonomura, Akira

    2012-01-01

    The magnetic domain structure of the writer poles of perpendicular magnetic recording heads was studied using electron holography. Although the domain structure of a 100-nm-thick writer pole could be observed with a 300 kV transmission electron microscope, that of the 250-nm-thick writer pole could not be analyzed due to the limited transmission capability of the instrument. On the other hand, the detailed domain structure of the 250-nm-thick writer pole was successfully analyzed by a 1 MV electron microscope using its high transmission capability. The thickness and material dependency of the domain structure of a writer pole were discussed.

  15. Magnetic record of extreme marine inundation events at Las Salinas site, Jalisco, Mexican Pacific coast

    Czech Academy of Sciences Publication Activity Database

    Černý, Jan; Ramírez-Herrera, M.-T.; Bógalo, M.-F.; Goguitchaichvili, A.; Castillo-Aja, R.; Morales, J.; Sanchez-Cabeza, J. A.; Ruiz-Fernandez, A. C.

    2016-01-01

    Roč. 58, č. 3 (2016), s. 342-357 ISSN 0020-6814 Institutional support: RVO:67985831 Keywords : anisotropy of magnetic susceptibility (AMS) * rock magnetic properties * tsunami * thermomagnetic curves * Mexican Pacific coast * variability Subject RIV: DE - Earth Magnetism, Geodesy, Geography Impact factor: 2.262, year: 2016

  16. Comparison of alignment tensors generated for native tRNAVal using magnetic fields and liquid crystalline media

    International Nuclear Information System (INIS)

    Latham, Michael P.; Hanson, Paul; Brown, Darin J.; Pardi, Arthur

    2008-01-01

    Residual dipolar couplings (RDCs) complement standard NOE distance and J-coupling torsion angle data to improve the local and global structure of biomolecules in solution. One powerful application of RDCs is for domain orientation studies, which are especially valuable for structural studies of nucleic acids, where the local structure of a double helix is readily modeled and the orientations of the helical domains can then be determined from RDC data. However, RDCs obtained from only one alignment media generally result in degenerate solutions for the orientation of multiple domains. In protein systems, different alignment media are typically used to eliminate this orientational degeneracy, where the combination of RDCs from two (or more) independent alignment tensors can be used to overcome this degeneracy. It is demonstrated here for native E. coli tRNA Val that many of the commonly used liquid crystalline alignment media result in very similar alignment tensors, which do not eliminate the 4-fold degeneracy for orienting the two helical domains in tRNA. The intrinsic magnetic susceptibility anisotropy (MSA) of the nucleobases in tRNA Val was also used to obtain RDCs for magnetic alignment at 800 and 900 MHz. While these RDCs yield a different alignment tensor, the specific orientation of this tensor combined with the high rhombicity for the tensors in the liquid crystalline media only eliminates two of the four degenerate orientations for tRNA Val . Simulations are used to show that, in optimal cases, the combination of RDCs obtained from liquid crystalline medium and MSA-induced alignment can be used to obtain a unique orientation for the two helical domains in tRNA Val

  17. Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method

    Directory of Open Access Journals (Sweden)

    Keyun Chen

    2016-09-01

    Full Text Available Micro-needle electrodes (MEs have attracted more and more attention for monitoring physiological electrical signals, including electrode-skin interface impedance (EII, electromyography (EMG and electrocardiography (ECG recording. A magnetization-induced self-assembling method (MSM was developed to fabricate a microneedle array (MA. A MA coated with Ti/Au film was assembled as a ME. The fracture and insertion properties of ME were tested by experiments. The bio-signal recording performance of the ME was measured and compared with a typical commercial wet electrode (Ag/AgCl electrode. The results show that the MA self-assembled from the magnetic droplet array under the sum of gravitational surface tension and magnetic potential energies. The ME had good toughness and could easily pierce rabbit skin without being broken or buckling. When the compression force applied on the ME was larger than 2 N, ME could stably record EII, which was a lower value than that measured by Ag/AgCl electrodes. EMG signals collected by ME varied along with the contraction of biceps brachii muscle. ME could record static ECG signals with a larger amplitude and dynamic ECG signals with more distinguishable features in comparison with a Ag/AgCl electrode, therefore, ME is an alternative electrode for bio-signal monitoring in some specific situations.

  18. Sputtering gases and pressure effects on the microstructure, magnetic properties and recording performance of TbFeCo films

    International Nuclear Information System (INIS)

    Murakami, Motoyoshi; Birukawa, Masahiro

    2008-01-01

    The MsHc value is considered to be a key factor in high-density recording, and controlling the microstructure on the magnetic underlayer was found to be an effective way of increasing the MsHc of the amorphous TbFeCo magneto-optical (MO) medium. In this paper, we investigate the TbFeCo film's magnetic properties and the effects on the microcolumnar structure, which depends on the sputtering conditions of using various sputtering gases including Ar, Kr, and Xe, and the recording characteristics of TbFeCo memory layers. With heavy sputtering gases such as Kr or Xe, the columnar structure can be prepared in a TbFeCo film at a pressure lower than 1.0 Pa. The columnar structure of a recording layer can be effectively formed thanks to the effects of the magnetic underlayer, which has a fine surface even in the sputtering process in which Xe gas is used. The above applies to the sputtering process in which Ar gas is used. Also, when Xe gas is used in the sputtering process, coercivity Hc is increased through the formation of a well-segregated microcolumnar structure built on domain wall pinning sites, and we obtain a large MsHc and a high squareness ratio of the Kerr-hysteresis loop. Our results indicate that processing a TbFeCo film with heavy sputtering gases is suitable for tiny mark stability because the temperature gradient of Hc is increased. The objective of the low-pressure sputtering process using Xe gas to produce the columnar structure is to achieve ultra-high-density recording with tiny mark stability in the TbFeCo medium. This has been confirmed with magnetic force microscope (MFM) images of stable tiny marks recorded on TbFeCo film

  19. CoPt/TiN films nanopatterned by RF plasma etching towards dot-patterned magnetic media

    Science.gov (United States)

    Szívós, János; Pothorszky, Szilárd; Soltys, Jan; Serényi, Miklós; An, Hongyu; Gao, Tenghua; Deák, András; Shi, Ji; Sáfrán, György

    2018-03-01

    CoPt thin films as possible candidates for Bit Patterned magnetic Media (BPM) were prepared and investigated by electron microscopy techniques and magnetic measurements. The structure and morphology of the Direct Current (DC) sputtered films with N incorporation were revealed in both as-prepared and annealed state. Nanopatterning of the samples was carried out by means of Radio Frequency (RF) plasma etching through a Langmuir-Blodgett film of silica nanospheres that is a fast and high throughput technique. As a result, the samples with hexagonally arranged 100 nm size separated dots of fct-phase CoPt were obtained. The influence of the order of nanopatterning and anneling on the nanostructure formation was revealed. The magnetic properties of the nanopatterned fct CoPt films were investigated by Vibrating Sample Magnetometer (VSM) and Magnetic Force Microscopy (MFM). The results show that CoPt thin film nanopatterned by means of the RF plasma etching technique is promising candidate to a possible realization of BPM. Furthermore, this technique is versatile and suitable for scaling up to technological and industrial applications.

  20. Effects of sub-domain structure on initial magnetization curve and domain size distribution of stacked media

    International Nuclear Information System (INIS)

    Sato, S.; Kumagai, S.; Sugita, R.

    2015-01-01

    In this paper, in order to confirm the sub-domain structure in stacked media demagnetized with in-plane field, initial magnetization curves and magnetic domain size distribution were investigated. Both experimental and simulation results showed that an initial magnetization curve for the medium demagnetized with in-plane field (MDI) initially rose faster than that for the medium demagnetized with perpendicular field (MDP). It is inferred that this is because the MDI has a larger number of domain walls than the MDP due to the existence of the sub-domains, resulting in an increase in the probability of domain wall motion. Dispersion of domain size for the MDI was larger than that for the MDP. This is because sub-domains are formed not only inside the domain but also at the domain boundary region, and they change the position of the domain boundary to affect the domain size. - Highlights: • An initial magnetization curve for MDI initially rose faster than that for MDP. • Dispersion of domain size for the MDI was larger than that for the MDP. • Experimental and simulation results can be explained by existence of sub-domains

  1. Visualized effect of oxidation on magnetic recording fidelity in pseudo-single-domain magnetite particles

    DEFF Research Database (Denmark)

    Almeida, Trevor P.; Kasama, Takeshi; Muxworthy, Adrian R.

    2014-01-01

    fidelity of Fe3O4 particles is greatly diminished over time by progressive oxidation to less magnetic iron oxides, such as maghemite (γ-Fe2O3), with consequent alteration of remanent magnetization potentially having important geological significance. Here we use the complementary techniques...... of environmental transmission electron microscopy and off-axis electron holography to induce and visualize the effects of oxidation on the magnetization of individual nanoscale Fe3O4 particles as they transform towards γ-Fe2O3. Magnetic induction maps demonstrate a change in both strength and direction of remanent...... magnetization within Fe3O4 particles in the size range dominant in rocks, confirming that oxidation can modify the original stored magnetic information....

  2. 75 FR 41899 - Records Schedules; Availability and Request for Comments

    Science.gov (United States)

    2010-07-19

    ... to site selection. 33. Federal Communications Commission, Media Bureau (N1-173-10-3, 2 items, 2..., Office of Public Affairs (N1-60-10-2, 3 items, 2 temporary items). Content posted to social media for... create billions of records on paper, film, magnetic tape, [[Page 41900

  3. Grain size dependent magnetic discrimination of Iceland and South Greenland terrestrial sediments in the northern North Atlantic sediment record

    Science.gov (United States)

    Hatfield, Robert G.; Stoner, Joseph S.; Reilly, Brendan T.; Tepley, Frank J.; Wheeler, Benjamin H.; Housen, Bernard A.

    2017-09-01

    We use isothermal and temperature dependent in-field and magnetic remanence methods together with electron microscopy to characterize different sieved size fractions from terrestrial sediments collected in Iceland and southern Greenland. The magnetic fraction of Greenland silts (3-63 μm) and sands (>63 μm) is primarily composed of near-stoichiometric magnetite that may be oxidized in the finer clay (samples, in contrast to coarser PSD and multi-domain (MD) discrete magnetites from southern Greenland. We demonstrate the potential of using magnetic properties of the silt fraction for source unmixing by creating known endmember mixtures and by using naturally mixed marine sediments from the Eirik Ridge south of Greenland. We develop a novel approach to ferrimagnetic source unmixing by using low temperature magnetic susceptibility curves that are sensitive to the different crystallinity and cation substitution characteristics of the different source regions. Covariation of these properties with hysteresis parameters suggests sediment source changes have driven the magnetic mineral variations observed in Eirik Ridge sediments since the last glacial maximum. These observations assist the development of a routine method and interpretative framework to quantitatively determine provenance in a geologically realistic and meaningful way and assess how different processes combine to drive magnetic variation in the North Atlantic sediment record.

  4. Changes in collection efficiency in nylon net filter media through magnetic alignment of elongated aerosol particles.

    Science.gov (United States)

    Lam, Christopher O; Finlay, W H

    2009-10-01

    Fiber aerosols tend to align parallel to surrounding fluid streamlines in shear flows, making their filtration more difficult. However, previous research indicates that composite particles made from cromoglycic acid fibers coated with small nanoscaled magnetite particles can align with an applied magnetic field. The present research explored the effect of magnetically aligning these fibers to increase their filtration. Nylon net filters were challenged with the aerosol fibers, and efficiency tests were performed with and without a magnetic field applied perpendicular to the flow direction. We investigated the effects of varying face velocities, the amount of magnetite material on the aerosol particles, and magnetic field strengths. Findings from the experiments, matched by supporting single-fiber theories, showed significant efficiency increases at the low face velocity of 1.5 cm s(-1) at all magnetite compositions, with efficiencies more than doubling due to magnetic field alignment in certain cases. At a higher face velocity of 5.12 cm s(-1), filtration efficiencies were less affected by the magnetic field alignment being, at most, 43% higher for magnetite weight compositions up to 30%, while at a face velocity of 10.23 cm s(-1) alignment effects were insignificant. In most cases, efficiencies became independent of magnetic field strength above 50 mT, suggesting full alignment of the fibers. The present data suggest that fiber alignment in a magnetic field may warrant applications in the filtration and detection of fibers, such as asbestos.

  5. Magma flow recorded by magmatic and magnetic fabrics in a shallow granitic pluton: La Gloria Pluton, central Chile

    Science.gov (United States)

    Payacán, I. J.; Gutiérrez, F. J.; Gelman, S. E.; Bachmann, O.; Parada, M. A.

    2013-12-01

    To better understand the dynamics of a small, shallow, silicic magma reservoir, magmatic and magnetic (AMS) fabrics are compared in samples obtained from La Gloria Pluton (LGP), a 10 Ma granitic intrusion located in southern Andes. The magnetic fabric of LGP, mainly given by magnetite, is characterized by oblate shapes. Magnetic lineations have a NW trend with subhorizontal dip, following the main pluton elongation, while magnetic foliation planes have dips varying gradually from vertical at the walls to subhorizontal toward the center and the roof of the pluton. On the basis of numerical simulations, magnetic fabric was interpreted to represent the shear record induced by magmatic convection along solidification fronts as the reservoir reached its rheological locking point. Magmatic fabric (mineral orientation) was determined on 12 samples along the pluton. Three mutually orthogonal thin sections were produced for each sample, perpendicular to the AMS tensor axes. Size and orientation of individual crystals were obtained by image analysis. A 2-D tensor for two mineral groups (plagioclase and amphibole+biotitie) was defined in each mineral plane projecting the crystal lengths on the main crystal orientation (given by Bingham statistics). A 3-D magmatic fabric tensor was obtained. In order to compare the magmatic and magnetic fabrics, magmatic anisotropy parameters were defined similar to the AMS tensors. Magmatic fabric and anisotropy parameter values vary depending on the location inside the pluton: (1) Samples located at the borders exhibit vertical foliations and lineations with a NW trend, similar to the magnetic fabric tensors and higher anisotropy values for plagioclase than amphibole+biotite,; (2) samples located at the center of the LGP commonly present subvertical foliations/lineations, which differ from the magnetic fabric, and higher magmatic anisotropy degree values for amphibole+biotite than plagioclase. Based on numerical simulations of the fluid

  6. A media maniac's guide to removable mass storage media

    Science.gov (United States)

    Kempster, Linda S.

    1996-01-01

    This paper addresses at a high level, the many individual technologies available today in the removable storage arena including removable magnetic tapes, magnetic floppies, optical disks and optical tape. Tape recorders represented below discuss logitudinal, serpantine, logitudinal serpantine,and helical scan technologies. The magnetic floppies discussed will be used for personal electronic in-box applications.Optical disks still fill the role for dense long-term storage. The media capacities quoted are for native data. In some cases, 2 KB ASC2 pages or 50 KB document images will be referenced.

  7. Annual Conference on Magnetism and Magnetic Materials, 29th, Pittsburgh, PA, November 8-11, 1983, Proceedings

    International Nuclear Information System (INIS)

    Hasegawa, R.; Koon, N.C.; Cooper, B.R.

    1984-01-01

    Various topics on magnetism and magnetic materials are addressed. The subjects considered include: spin glasses, amorphous magnetism, actinide and rare earth intermetallics, magnetic excitation, itinerant magnetism and magnetic structure, valence instabilities, Kondo effect, transport and Hall effects, mixed valence and Kondo compounds, superconductivity and magnetism, d and f electron magnetism and superconductivity, Fe-based microcrystalline and permanent magnetic alloys, hard and soft magnetic materials, and magnetooptics. Also discussed are: numerical methods for magnetic field computation, recording theory and experiments, recording heads and media, magnetic studies via hyperfine interactions, magnetic semiconductors, magnet insulators, transition metal systems, random fields, critical phenomena and magnetoelastic effects and resonance, surfaces and interfaces, magnetostatic waves and resonance, bubble materials and implantation, bubble devices and physics, magnetic separation, ferrofluids, magnetochemistry, new techniques and materials, and new applications

  8. Unravelling the magnetic record in marine and continental sediments : climatic versus geomagnetic signals

    NARCIS (Netherlands)

    Kruiver, Pauline Pascal

    2001-01-01

    Magnetic iron oxides and iron sulfides are present as trace constituents in sediments. These magnetic particles can carry a natural remanent magnetisation (NRM). When the sediment consolidates and lithifies after deposition, the direction of the then ambient field is preserved. The amount of

  9. Electron beam curable branched chain polyurethane acrylates for magnetic media coatings

    International Nuclear Information System (INIS)

    Ukachi, Takashi; Haga, Kei-ichi; Matsumura, Yoshio

    1989-01-01

    Electron beam curable binder resins have been studied to realize the high quality magnetic coatings. It was supposed that resins with a higher crosslink density could lead to magnetic coatings with higher abrasion resistance. Branched chain polyurethane acrylates show a higher degree of cure by irradiation with an electron beam in comparison with linear polyurethane acrylates. This paper describes the potential wear resistance between properties of magnetic coatings and the physical properties of the cured unpigmented branched chain polyurethane acrylates that were used as the binder resins. (author)

  10. Silicon nitride gradient film as the underlayer of ultra-thin tetrahedral amorphous carbon overcoat for magnetic recording slider

    Energy Technology Data Exchange (ETDEWEB)

    Wang Guigen, E-mail: wanggghit@yahoo.com [Shenzhen Graduate School, Harbin Institute of Technology, Shenzhen 518055 (China); Kuang Xuping; Zhang Huayu; Zhu Can [Shenzhen Graduate School, Harbin Institute of Technology, Shenzhen 518055 (China); Han Jiecai [Shenzhen Graduate School, Harbin Institute of Technology, Shenzhen 518055 (China); Center for Composite Materials, Harbin Institute of Technology, Harbin 150080 (China); Zuo Hongbo [Center for Composite Materials, Harbin Institute of Technology, Harbin 150080 (China); Ma Hongtao [SAE Technologies Development (Dongguan) Co., Ltd., Dongguan 523087 (China)

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer The ultra-thin carbon films with different silicon nitride (Si-N) film underlayers were prepared. Black-Right-Pointing-Pointer It highlighted the influences of Si-N underlayers. Black-Right-Pointing-Pointer The carbon films with Si-N underlayers obtained by nitriding especially at the substrate bias of -150 V, can exhibit better corrosion protection properties - Abstract: There are higher technical requirements for protection overcoat of magnetic recording slider used in high-density storage fields for the future. In this study, silicon nitride (Si-N) composition-gradient films were firstly prepared by nitriding of silicon thin films pre-sputtered on silicon wafers and magnetic recording sliders, using microwave electron cyclotron resonance plasma source. The ultra-thin tetrahedral amorphous carbon films were then deposited on the Si-N films by filtered cathodic vacuum arc method. Compared with amorphous carbon overcoats with conventional silicon underlayers, the overcoats with Si-N underlayers obtained by plasma nitriding especially at the substrate bias of -150 V, can provide better corrosion protection for high-density magnetic recording sliders.

  11. Silicon nitride gradient film as the underlayer of ultra-thin tetrahedral amorphous carbon overcoat for magnetic recording slider

    International Nuclear Information System (INIS)

    Wang Guigen; Kuang Xuping; Zhang Huayu; Zhu Can; Han Jiecai; Zuo Hongbo; Ma Hongtao

    2011-01-01

    Highlights: ► The ultra-thin carbon films with different silicon nitride (Si-N) film underlayers were prepared. ► It highlighted the influences of Si-N underlayers. ► The carbon films with Si-N underlayers obtained by nitriding especially at the substrate bias of −150 V, can exhibit better corrosion protection properties - Abstract: There are higher technical requirements for protection overcoat of magnetic recording slider used in high-density storage fields for the future. In this study, silicon nitride (Si-N) composition-gradient films were firstly prepared by nitriding of silicon thin films pre-sputtered on silicon wafers and magnetic recording sliders, using microwave electron cyclotron resonance plasma source. The ultra-thin tetrahedral amorphous carbon films were then deposited on the Si-N films by filtered cathodic vacuum arc method. Compared with amorphous carbon overcoats with conventional silicon underlayers, the overcoats with Si-N underlayers obtained by plasma nitriding especially at the substrate bias of −150 V, can provide better corrosion protection for high-density magnetic recording sliders.

  12. Single-sided Nuclear Magnetic Resonance for condition monitoring of cross-linked polyethylene exposed to aggressive media

    Energy Technology Data Exchange (ETDEWEB)

    Adams, A., E-mail: Alina.Adams@itmc.rwth-aachen.de [Institut für Technische und Makromolekulare Chemie, RWTH Aachen University, Templergraben 55, 52056 Aachen (Germany); Piechatzek, A.; Schmitt, G. [Institut für Instandhaltung und Korrosionsschutztechnik gGmbH, Kalkofen 4, 58638 Iserlohn (Germany); Siegmund, G. [ExxonMobil Production Germany, Riethorst 12, 30659 Hannover (Germany)

    2015-08-05

    The potential of single-sided Nuclear Magnetic Resonance (NMR) to monitor truly non-invasive changes in polymer materials during aging under aggressive media is for the first time evaluated. For this, the NMR method is used in combination with other condition monitoring methods including mechanical measurements, mass uptake, and differential scanning calorimetry. It is validated by studying for the first time the aging kinetics of silane cross-linked polyethylene (PEX) exposed to media used in oil and gas production and transportation, including aliphatic and aromatic hydrocarbons, sulphur solvents, and corrosion inhibitors in combination with CO{sub 2} and H{sub 2}S. All investigated parameters changed, with the strongest effects detected for the NMR chain mobility and in the presence of hydrocarbons. Furthermore, a universal linear correlation curve could be established between the depression of the tensile strength and the chain mobility. This result represents a fundamental step towards establishing single-sided NMR as a new analytical tool for in situ condition monitoring of polyethylene working under sour conditions. The proposed approach can be easily extended to other polymer materials. - Highlights: • The changes in PEX exposed to sour media were quantified for the first time. • The strongest morphological changes in PEX were detected under exposure to hydrocarbon media. • The chain mobility measured truly non-destructively by single-sided NMR showed the highest sensitivity to the aging process. • A universal linear correlation curve was found between the chain mobility and the tensile strength. • Single-sided NMR was validated as a condition monitoring tool.

  13. Verification of novel magnetic nanoparticles as a contrast media for MRI-CT/SPECT imaging

    Czech Academy of Sciences Publication Activity Database

    Kostiv, Uliana; Laudová, B.; Lobaz, Volodymyr; Kučka, Jan; Franová, P.; Hrubý, Martin; Horák, Daniel; Šefc, L.

    2017-01-01

    Roč. 13, č. 1 (2017), s. 156 ISSN 1336-7242. [Zjazd chemikov /69./. 11.09.2017-15.09.2017, Horný Smokovec] Institutional support: RVO:61389013 Keywords : magnetic nanoparticles * diagnostics Subject RIV: CD - Macromolecular Chemistry

  14. Values of the Earth's Magnetic Field Components X, Y, and Z Recorded in Finland

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set was generated by the Finish Academy of Science from magnetic data collected during the International Magnetospheric Study, 1976-1978. The data were...

  15. A magnetic record of heavy metal pollution in the Yangtze River subaqueous delta

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Chenyin [State Key Laboratory of Estuarine and Coastal Research, East China Normal University, Shanghai 200062 (China); Zhang, Weiguo, E-mail: wgzhang@sklec.ecnu.edu.cn [State Key Laboratory of Estuarine and Coastal Research, East China Normal University, Shanghai 200062 (China); Ma, Honglei [State Key Laboratory of Estuarine and Coastal Research, East China Normal University, Shanghai 200062 (China); Feng, Huan [Department of Earth and Environmental Studies, Montclair State University, NJ 07043 (United States); Lu, Honghua [Department of Geography, College of Resources and Environmental Science, East China Normal University, Shanghai 200241 (China); Dong, Yan [State Key Laboratory of Estuarine and Coastal Research, East China Normal University, Shanghai 200062 (China); Institute of Geographic Engineering Technology, School of Geographical Science, Nantong University, Nantong 226007 (China); Yu, Lizhong [State Key Laboratory of Estuarine and Coastal Research, East China Normal University, Shanghai 200062 (China)

    2014-04-01

    The rapid industrial development in the Yangtze River watershed over the last several decades has drawn great attention with respect to heavy metal pollution to the Yangtze River estuary and nearby coastal areas. In this study, a 236 cm long sediment core was retrieved from the Yangtze River subaqueous delta (122°36′ E, 31°00′ N) in 2008 and analyzed for magnetic properties and geochemical compositions to investigate heavy metal pollution history. The activity of {sup 137}Cs peaked at depth 140 cm, with a broad plateau between 120 cm and 140 cm, suggesting an average sedimentation rate of 3.11 cm yr{sup −1} for the upper 140 cm layer. Magnetic susceptibility (χ), saturation isothermal remanent magnetization (SIRM), anhysteretic remanent magnetization (χ{sub ARM}) and heavy metal enrichment factors (EF) all showed an upward increase trend above depth 140 cm, suggesting that increased ferrimagnetic mineral concentration was accompanied by heavy metal enrichment in the sediment. Geochemical and granolumetric analyses showed that sediment sources and particle sizes played minor roles in the variations of magnetic properties. The effect of diagenesis, which can lead to the selective removal of magnetic minerals, was noticeable in the lower part of the core (140–236 cm). Co-variation between magnetic properties (χ, SIRM and χ{sub ARM}) and EF of Cu and Pb suggests that the elevated ferrimagnetic mineral concentration can be used as an indicator of heavy metal pollution in the reconstruction of environmental changes in estuarine and coastal settings. - Highlights: • Magnetic parameters can be used as heavy metal pollution proxy. • Heavy metal contents in the Yangtze River estuary increase since the 1960s. • Heavy metal pollution is largely driven by population growth in the catchment.

  16. Ordering and thermal excitations in dipolar coupled single domain magnet arrays (Presentation Recording)

    Science.gov (United States)

    Östman, Erik; Arnalds, Unnar; Kapaklis, Vassilios; Hjörvarsson, Björgvin

    2015-09-01

    For a small island of a magnetic material the magnetic state of the island is mainly determined by the exchange interaction and the shape anisotropy. Two or more islands placed in close proximity will interact through dipolar interactions. The state of a large system will thus be dictated by interactions at both these length scales. Enabling internal thermal fluctuations, e.g. by the choice of material, of the individual islands allows for the study of thermal ordering in extended nano-patterned magnetic arrays [1,2]. As a result nano-magnetic arrays represent an ideal playground for the study of physical model systems. Here we present three different studies all having used magneto-optical imaging techniques to observe, in real space, the order of the systems. The first study is done on a square lattice of circular islands. The remanent magnetic state of each island is a magnetic vortex structure and we can study the temperature dependence of the vortex nucleation and annihilation fields [3]. The second are long chains of dipolar coupled elongated islands where the magnetization direction in each island only can point in one of two possible directions. This creates a system which in many ways mimics the Ising model [4] and we can relate the correlation length to the temperature. The third one is a spin ice system where elongated islands are placed in a square lattice. Thermal excitations in such systems resemble magnetic monopoles [2] and we can investigate their properties as a function of temperature and lattice parameters. [1] V. Kapaklis et al., New J. Phys. 14, 035009 (2012) [2] V. Kapaklis et al., Nature Nanotech 9, 514(2014) [3] E. Östman et al.,New J. Phys. 16, 053002 (2014) [4] E. Östman et al.,Thermal ordering in mesoscopic Ising chains, In manuscript.

  17. A magnetic record of heavy metal pollution in the Yangtze River subaqueous delta

    International Nuclear Information System (INIS)

    Dong, Chenyin; Zhang, Weiguo; Ma, Honglei; Feng, Huan; Lu, Honghua; Dong, Yan; Yu, Lizhong

    2014-01-01

    The rapid industrial development in the Yangtze River watershed over the last several decades has drawn great attention with respect to heavy metal pollution to the Yangtze River estuary and nearby coastal areas. In this study, a 236 cm long sediment core was retrieved from the Yangtze River subaqueous delta (122°36′ E, 31°00′ N) in 2008 and analyzed for magnetic properties and geochemical compositions to investigate heavy metal pollution history. The activity of 137 Cs peaked at depth 140 cm, with a broad plateau between 120 cm and 140 cm, suggesting an average sedimentation rate of 3.11 cm yr −1 for the upper 140 cm layer. Magnetic susceptibility (χ), saturation isothermal remanent magnetization (SIRM), anhysteretic remanent magnetization (χ ARM ) and heavy metal enrichment factors (EF) all showed an upward increase trend above depth 140 cm, suggesting that increased ferrimagnetic mineral concentration was accompanied by heavy metal enrichment in the sediment. Geochemical and granolumetric analyses showed that sediment sources and particle sizes played minor roles in the variations of magnetic properties. The effect of diagenesis, which can lead to the selective removal of magnetic minerals, was noticeable in the lower part of the core (140–236 cm). Co-variation between magnetic properties (χ, SIRM and χ ARM ) and EF of Cu and Pb suggests that the elevated ferrimagnetic mineral concentration can be used as an indicator of heavy metal pollution in the reconstruction of environmental changes in estuarine and coastal settings. - Highlights: • Magnetic parameters can be used as heavy metal pollution proxy. • Heavy metal contents in the Yangtze River estuary increase since the 1960s. • Heavy metal pollution is largely driven by population growth in the catchment

  18. 106 17 Telemetry Standards Annex A.2 Magnetic Tape Recorder and Reproducer Information and Use Criteria

    Science.gov (United States)

    2017-07-31

    from the average line defining the azimuth. Since both components affect data simultaneity from record to reproduce, the gap scatter measurement is...pulse at the reproduce amplifier output, still leaves two interdependent parameters unspecified. These parameters are (1) polarity inversion or non... inversion in record and playback amplifiers and (2) record or playback head winding sense. For the purpose of head replacement, it is necessary that

  19. Some problems associated with the inversion of polar magnetic substorm data recorded at the Earth's surface

    International Nuclear Information System (INIS)

    Mareschal, M.

    1975-01-01

    The major thrust of this dissertation was to test an original method for resolving the current system associated with polar magnetic substorms from ground based magnetic observations. This method is based on a general technique of inversion reviewed by Wiggins in 1972 and appears to give quite satisfactory results, at least, when the current system considered is simulated by a three-dimensional current system consisting of field-aligned currents flowing down to the ionosphere, westward in the ionosphere, and back up again to the magnetosphere. Conclusions suggest that, for the purpose of inverting polar magnetic substorm data with the use of the three-dimensional model of current, the Earth's induction effects can be simulated by introducing a perfectly conducting layer inside the Earth. However, the depth of this equivalent conductor should be allowed to vary with the source frequency as the substorm develops with time. To determine how satisfactorily each model parameter could be expected to be resolved during the process of inversion, a study of the magnetic disturbance variations under specific parameter variations was then performed. The results of that study were encouraging enough to foster the inversion of an actual polar magnetic substorm data, the event of June 15, 1970. Despite the success of the enterprise, it seems reasonable to suggest that the technique of inversion should be further tested before being systematically used to resolve polar magnetic substorms

  20. Molecular dynamics in porous media studied by nuclear magnetic resonance techniques

    International Nuclear Information System (INIS)

    Mattea, C.

    2006-01-01

    Field cycling NMR relaxometry was used to study dynamics of fluids under confinement in different scenarios: fluids flowing through porous media, fluids partially filling porous media and polymer melts in nanoscopic pores. Diffusion in partially filled porous media was also studied with the aid of an NMR diffusometry technique. It is shown that hydrodynamic flow influences the spin-lattice relaxation rate of water confined in mesoscopic porous media under certain conditions. The effect is predicted by an analytical theory and Monte Carlo simulations, and confirmed experimentally by field-cycling NMR relaxometry. Field-cycling NMR relaxometry has been applied to polar and non polar adsorbates in partially filled silica porous glasses. The dependence of the spin-lattice relaxation rate on the filling degree shows that limits for slow and fast exchange between different phases can be distinguished and identified depending on the pore size and polarity of the solvents. Diffusion in the same unsaturated systems was studied with the aid of NMR diffusometry technique. The effective diffusion coefficient of solvents with different polarities displays opposite tendencies as a function of the liquid content. A two-phase fast exchange model including Knudsen and ordinary diffusion and different effective tortuosities is presented accounting for these phenomena. In the case of polymer melts confined in narrow artificial tubes of a porous solid matrix with variable diameter (9 to 57 nm), the characteristics of reptation were experimentally verified using proton field cycling NMR relaxometry technique. This observation is independent of the molecular mass and pore size. In bulk, the same polymer melts show either Rouse or renormalized Rouse dynamics, depending on the molecular mass. The polymers under confinement show features specific for reptation even with a pore diameter 15 times larger than the Flory radius while bulk melts of the same polymers do not. (orig.)

  1. A magnetic record of heavy metal pollution in the Yangtze River subaqueous delta.

    Science.gov (United States)

    Dong, Chenyin; Zhang, Weiguo; Ma, Honglei; Feng, Huan; Lu, Honghua; Dong, Yan; Yu, Lizhong

    2014-04-01

    The rapid industrial development in the Yangtze River watershed over the last several decades has drawn great attention with respect to heavy metal pollution to the Yangtze River estuary and nearby coastal areas. In this study, a 236 cm long sediment core was retrieved from the Yangtze River subaqueous delta (122°36' E, 31°00' N) in 2008 and analyzed for magnetic properties and geochemical compositions to investigate heavy metal pollution history. The activity of (137)Cs peaked at depth 140 cm, with a broad plateau between 120 cm and 140 cm, suggesting an average sedimentation rate of 3.11 cm yr(-1) for the upper 140 cm layer. Magnetic susceptibility (χ), saturation isothermal remanent magnetization (SIRM), anhysteretic remanent magnetization (χARM) and heavy metal enrichment factors (EF) all showed an upward increase trend above depth 140 cm, suggesting that increased ferrimagnetic mineral concentration was accompanied by heavy metal enrichment in the sediment. Geochemical and granolumetric analyses showed that sediment sources and particle sizes played minor roles in the variations of magnetic properties. The effect of diagenesis, which can lead to the selective removal of magnetic minerals, was noticeable in the lower part of the core (140-236 cm). Co-variation between magnetic properties (χ, SIRM and χARM) and EF of Cu and Pb suggests that the elevated ferrimagnetic mineral concentration can be used as an indicator of heavy metal pollution in the reconstruction of environmental changes in estuarine and coastal settings. Copyright © 2014. Published by Elsevier B.V.

  2. Chiral heat wave and mixing of magnetic, vortical and heat waves in chiral media

    International Nuclear Information System (INIS)

    Chernodub, M.N.

    2016-01-01

    We show that a hot rotating fluid of relativistic chiral fermions possesses a new gapless collective mode associated with coherent propagation of energy density and chiral density waves along the axis of rotation. This mode, which we call the Chiral Heat Wave, emerges due to a mixed gauge-gravitational anomaly. At finite density the Chiral Heat Wave couples to the Chiral Vortical Wave while in the presence of an external magnetic field it mixes with the Chiral Magnetic Wave. The coupling of the Chiral Magnetic and Chiral Vortical Waves is also demonstrated. We find that the coupled waves — which are coherent fluctuations of the vector, axial and energy currents — have generally different velocities compared to the velocities of the individual waves.

  3. The influence of oxygen and nitrogen doping on GeSbTe phase-change optical recording media properties

    Energy Technology Data Exchange (ETDEWEB)

    Dimitrov, D.; Shieh, H.-P.D

    2004-03-15

    Nitrogen and oxygen doped and co-doped GeSbTe (GST) films for phase-change optical recording are investigated. It is found that the crystallization temperature increased as well as the crystalline microstructure refined by doping. The carrier-to-noise ratio (CNR) and erasability of phase-change optical disks are improved being up to 52 and 35 dB, respectively, by using an appropriate nitrogen doping or co-doping concentration in the recording layer. Optical disks with co-doped recording layer are found to be superior in the recording characteristics then the single doped recording layer disks.

  4. FAST MAGNETIC FIELD AMPLIFICATION IN THE EARLY UNIVERSE: GROWTH OF COLLISIONLESS PLASMA INSTABILITIES IN TURBULENT MEDIA

    Energy Technology Data Exchange (ETDEWEB)

    Falceta-Gonçalves, D. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Kowal, G. [Escola de Artes, Ciências e Humanidades, Universidade de São Paulo, Rua Arlindo Bettio, 1000, São Paulo, SP 03828-000 (Brazil)

    2015-07-20

    In this work we report on a numerical study of the cosmic magnetic field amplification due to collisionless plasma instabilities. The collisionless magnetohydrodynamic equations derived account for the pressure anisotropy that leads, in specific conditions, to the firehose and mirror instabilities. We study the time evolution of seed fields in turbulence under the influence of such instabilities. An approximate analytical time evolution of the magnetic field is provided. The numerical simulations and the analytical predictions are compared. We found that (i) amplification of the magnetic field was efficient in firehose-unstable turbulent regimes, but not in the mirror-unstable models; (ii) the growth rate of the magnetic energy density is much faster than the turbulent dynamo; and (iii) the efficient amplification occurs at small scales. The analytical prediction for the correlation between the growth timescales and pressure anisotropy is confirmed by the numerical simulations. These results reinforce the idea that pressure anisotropies—driven naturally in a turbulent collisionless medium, e.g., the intergalactic medium, could efficiently amplify the magnetic field in the early universe (post-recombination era), previous to the collapse of the first large-scale gravitational structures. This mechanism, though fast for the small-scale fields (∼kpc scales), is unable to provide relatively strong magnetic fields at large scales. Other mechanisms that were not accounted for here (e.g., collisional turbulence once instabilities are quenched, velocity shear, or gravitationally induced inflows of gas into galaxies and clusters) could operate afterward to build up large-scale coherent field structures in the long time evolution.

  5. Recognition of primary and diagenetic magnetizations to determine the magnetic polarity record and timing of deposition of the moat-fill rocks of the Oligocene Creede Caldera, Colorado

    Science.gov (United States)

    Reynolds, Richard L.; Rosenbaum, Joseph G.; Sweetkind, Donald S.; Lanphere, Marvin A.; Robert, Andrew P.; Verosub, Kenneth L.

    2000-01-01

    Sedimentary and volcaniclastic rocks of the Oligocene Creede Formation fill the moat of the Creede caldera, which formed at about 26.9 Ma during the eruption of the Snowshoe Mountain Tuff. Paleomagnetic and rock magnetic studies of two cores (418 and 703 m long) that penetrated the lower half of the Creede Formation, in addition to paleomagnetic and isotopic dating studies of stratigraphically bracketing volcanic units, provide information on the age and the time span of sedimentation of the caldera fill. Normal polarity magnetization are found in Snowshoe Mountain Tuff beneath the moat sediments; in detrital-magnetite-bearing graded tuffs near the bottom of the moat fill; in an ash-fall deposit about 200 m stratigraphically about the top of core 2; and in postcaldera lava flows of the Fisher Dacite that overlie the Creede Formation. Normal polarity also characterizes detrital-magnetite-bearing tuff and sandstone unites within the caldera moat rocks that did not undergo severe sulfidic alteration. The combination of initially low magnitude of remanent magnetization and the destructive effects of subsequent diagenetic sulfidization on detrital iron oxides results in a poor paleomagnetic record for the fine-grained sedimentary rocks of the Creede Formation. these fine-grained rocks have either normal or revered polarity magnetizations that are carried by magnetite and/or maghemite. Many more apparent reversals are found that can be accommodated by any geomagnetic polarity time scale over the interval spanned by the ages of the bracketing extrusive rocks. Moreover, opposite polarity magnetization are found in specimens separated by only a few centimeters, without intervening hiatuses, and by specimens in several tuff beds, each of which represents a single depositional event. These polarity changes cannot, therefore, be attributed to detrital remanent magnetization. Many polarity changes are apparently related to chemical remanent magnetizations carried by

  6. CoCr double-layered media with NiFe and CoZrNb soft-magnetic layers (invited)

    International Nuclear Information System (INIS)

    Bernards, J.P.C.; Schrauwen, C.P.G.; Zieren, V.; Luitjens, S.B.

    1988-01-01

    The magnetic, structural, and recording properties of CoCr double-layered media are investigated. The underlayer materials NiFe (crystalline) and CoZrNb (amorphous) were combined with two different kinds of intermediate layers: Ti (crystalline) and Ge (amorphous). Applying a bias voltage during sputtering of NiFe results in a low coercivity of the NiFe layer and in a high coercivity of the CoCr layer. The structure of the NiFe layer influences the structure of the CoCr layer. A Ti layer between the NiFe and CoCr layers decreases the in-plane remanence of the CoCr layer. The coercivity of all CoZrNb layers is low, independent of the application of a bias voltage. The orientation and structure of CoCr on CoZrNb can be improved by using a Ge intermediate layer, which results in a low coercivity of the CoCr. A Ti intermediate layer increases the coercivity. Ring heads show a dependence of spike noise on the underlayer coercivity and on the applied normal force. A probe-type head shows a dependence of its output on the CoCr coercivity, which may be understood in terms of demagnetization and writing depth

  7. Investigation of Fe-Si-N films as magnetic overcoat for high density recording disk drives

    International Nuclear Information System (INIS)

    Gauvin, M.; Talke, F. E.; Fullerton, E. E.

    2010-01-01

    A 50-nm-thick Fe-Si-N films were deposited via reactive magnetron cosputtering of independent Fe and Si targets, in Ar/N 2 gas mixture, under different dc Fe target power conditions. Magnetic properties, mechanical hardness and tribological properties were characterized as a function of the Fe target power by magnetometry, nanoindentation, and nanoscratch testing, respectively. Deposited samples were found to be ferromagnetic with a coercivity of approximately 20 Oe and a saturation magnetization increasing from 200 to 1100 emu/cm 3 as a function of Fe sputter power, i.e., values typical of soft magnetic materials. The mechanical hardness was found to be between 50% and 70% of the hardness of a pure SiN x film. Nanotribological properties of films deposited with a Fe target power ≥80 W degraded rapidly.

  8. Electromagnetic Momentum in Magnetic Media and the Abraham-Minkowski Controversy

    Science.gov (United States)

    Jimenez, J. L.; Campos, I.; Lopez-Marino, M. A.

    2011-01-01

    We explore the consequences of a force density, [image omitted], studied by some authors, for the device designed by Lai (1980 "Am. J. Phys. 48" 658) to analyse which definition of electromagnetic momentum density, either Minkowski's or Abraham's, is consistent with mechanical torques that arise from the change in time of a magnetic field, which…

  9. Computed tomography and magnetic resonance imaging contrast media injectors: technical feature review – what is really needed?

    Directory of Open Access Journals (Sweden)

    Friebe M

    2016-07-01

    Full Text Available Michael Friebe Institute of Medical Engineering, Otto-von-Guericke-University, Magdeburg, Germany Abstract: There has been little technical innovation over the last few years for contrast media (CM injectors that are used for diagnostic imaging (computed tomography [CT], magnetic resonance imaging [MRI], and hybrid imaging systems, such as positron emission tomography–CT or magnetic resonance–positron emission tomography examinations. The medical need of CM for the enhancement of diagnostic images has been around for a long time, but the application of the CM into the blood stream comes with potential medical complications for the patient and requires a lot of operator experience and training. Most power injector systems that are currently used can do significantly more than what is typically required; this complexity however, adds error potential and cost. This paper focuses on the main features that CM injector systems should have and highlights the technical developments that are useful to have but which add complexity and cost, increase setup time, and require intensive training for safe use. CM injection protocols are very different between CT and MRI, with CT requiring many more variances, has a need for multiphase protocols, and requires a higher timing accuracy. A CM injector used in the MRI suite, on the other-hand, could only need a relatively time insensitive injection with a standard injection flow rate and a volume that is dependent on the patients’ weight. This would make easy and lightweight systems possible, which are able to safely and accurately perform the injection task, while allowing full MRI compatibility with relatively low cost investment and consumable costs. Keywords: power injector, contrast media injection, injection protocols, MRI compatibility

  10. A preliminary report on the use of functional magnetic resonance imaging with simultaneous urodynamics to record brain activity during micturition.

    Science.gov (United States)

    Krhut, Jan; Tintera, Jaroslav; Holý, Petr; Zachoval, Roman; Zvara, Peter

    2012-08-01

    We mapped brain activity during micturition using functional magnetic resonance imaging with simultaneous recording of urodynamic properties during slow bladder filling and micturition. We evaluated 12 healthy female volunteers 20 to 68 years old. Eight subjects could urinate while supine. Meaningful data were obtained on 6 of these subjects. Brain activity was recorded continuously during bladder filling and micturition. Functional magnetic resonance imaging measurements made during the micturition phase were used for the final analysis. Using group statistics we identified clusters of brain activity in the parahippocampal gyrus, anterior cingulate gyrus, inferior temporal gyrus and inferior frontal gyrus during micturition. At the individual level we also observed activation in the upper pontine region, thalamus and posterior cingulum. In subjects unable to void brain activation was documented in the frontal lobe and posterior cingulate gyrus but not in the pons, thalamus or anterior cingulate gyrus. In 5 subjects we identified a relevant pattern of brain activity during the terminal portion of the filling phase when the patient reported a strong desire to urinate. This new protocol allows for the localization of brain structures that are active during micturition. Data suggest that additional validation studies are needed. Future studies will test modifications that include more detailed monitoring of bladder sensation, stratifying subjects based on age and gender, and increasing the number of data points by adding subjects and the number of micturitions recorded in a single subject. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. A new manganese-based single-molecule magnet with a record-high antiferromagnetic phase transition temperature

    International Nuclear Information System (INIS)

    Cui Yan; Li Yan-Rong; Li Rui-Yuan; Wang Yun-Ping

    2014-01-01

    We perform both dc and ac magnetic measurements on the single crystal of Mn 3 O(Et-sao) 3 (ClO 4 )(MeOH) 3 single-molecule magnet (SMM) when the sample is preserved in air for different durations. We find that, during the oxidation process, the sample develops into another SMM with a smaller anisotropy energy barrier and a stronger antiferromagnetic intermolecular exchange interaction. The antiferromagnetic transition temperature observed at 6.65 K in the new SMM is record-high for the antiferromagnetic phase transition in all the known SMMs. Compared to the original SMM, the only apparent change for the new SMM is that each molecule has lost three methyl groups as revealed by four-circle x-ray diffraction (XRD), which is thought to be the origin of the stronger antiferromagnetic intermolecular exchange interaction

  12. Sensitivity of sediment magnetic records to climate change during Holocene for the northern South China Sea

    Science.gov (United States)

    Ouyang, Tingping; Li, Mingkun; Zhao, Xiang; Zhu, Zhaoyu; Tian, Chengjing; Qiu, Yan; Peng, Xuechao; Hu, Qiao

    2016-05-01

    Magnetic property has been proved to be a sensitive proxy to climate change for both terrestrial and marine sediments. Based on the schedule frame established by AMS 14C dating of foraminifera, detail magnetic analyses were performed for core PC24 sediments at sampling intervals of 2 cm to discuss magnetic sensitivity of marine sediment to climate during Holocene for the northern South China Sea. The results indicated that: 1) Concentration dependent magnetic parameters are positive corresponding to variation of temperature. The frequency dependent susceptibility coefficient basically reflected the variation in humidity; 2) XARM/SIRM was more sensitive to detrital magnetite particles and SIRM/X was more effective to biogenic magnetite particles. Variations of XARM/SIRM and SIRM/X are corresponding to precipitation and temperature, respectively; 3) the Holocene Megathermal in the study area was identified as 7.5-3.4 cal. ka BP. The warmest stage of Holocene for the study area should be during 6.1 to 3.9 cal. ka BP; 4) The 8 ka cold event was characterized as cold and dry during 8.55 to 8.25 cal. ka BP; 5) During early and middle Holocene, the climate combinations were warm dry and cold wet. It turned to warm and wet after 2.7 cal. ka BP.

  13. Sensitivity of sediment magnetic records to climate change during Holocene for the northern South China Sea

    Directory of Open Access Journals (Sweden)

    Tingping eOuyang

    2016-05-01

    Full Text Available Magnetic property has been proved to be a sensitive proxy to climate change for both terrestrial and marine sediments. Based on the schedule frame established by AMS 14C dating of foraminifera, detail magnetic analyses were performed for core PC24 sediments at sampling intervals of 2 cm to discuss magnetic sensitivity of marine sediment to climate during Holocene for the northern South China Sea. The results indicated that: 1 Concentration dependent magnetic parameters are positive corresponding to variation of temperature. The frequency dependent susceptibility coefficient basically reflected the variation in humidity; 2 XARM/SIRM was more sensitive to detrital magnetite particles and SIRM/X was more effective to biogenic magnetite particles. Variations of XARM/SIRM and SIRM/X are corresponding to precipitation and temperature, respectively; 3 the Holocene Megathermal in the study area was identified as 7.5-3.4 cal. ka BP. The warmest stage of Holocene for the study area should be during 6.1 to 3.9 cal. ka BP; 4 The 8 ka cold event was characterized as cold and dry during 8.55 to 8.25 cal. ka BP; 5 During early and middle Holocene, the climate combinations were warm dry and cold wet. It turned to warm and wet after 2.7 cal. ka BP.

  14. Direct observation of the thermal demagnetization of magnetic vortex structures in nonideal magnetite recorders

    DEFF Research Database (Denmark)

    Almeida, Trevor P.; Muxworthy, Adrian R.; Kovács, András

    2016-01-01

    The thermal demagnetization of pseudo-single-domain (PSD) magnetite (Fe3O4) particles, which govern the magnetic signal in many igneous rocks, is examined using off-axis electron holography. Visualization of a vortex structure held by an individual Fe3O4 particle (~250nm in diameter) during in situ...

  15. Tailor-made nano-structured materials for perpendicular recording media and head-precise control of direct/indirect exchange coupling

    International Nuclear Information System (INIS)

    Takahashi, Migaku; Tsunoda, Masakiyo; Saito, Shin

    2009-01-01

    Tailor-made nano-structured spin materials obtained by precisely controlled nano-scale fabrication technologies for use in ultra-high density hard disk drives (HDDs), as well as an understanding of their nanomagnetics, are essential from the view point of materials, processes, and physics. Artificial control of the exchange coupling among ferromagnetic layers through the RKKY interaction (indirect) and direct exchange coupling represented as the exchange bias at the ferromagnetic (FM)/antiferromagnetic (AFM) interface are of great interest and have received significant attention to induce new modulated spin structures in conventional simple FM materials. In particular, soft magnetic under layer (SUL) with strong synthetic antiferromagnetic (SAF) coupling between two adjacent soft magnetic layers, exchange coupled stacked media introducing exchange coupling between FM layers and giant exchange anisotropy at the FM/AFM interface have attracted significant attention from the view point of applications. Within the framework of the present paper, we discuss future technical trends for SUL, granular media and the spin-valve head from the viewpoint of direct and/or indirect exchange coupling based on our recent results

  16. Assessing the wettability of unconsolidated porous media using low-field nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Manalo, Florence Pabalan

    2002-01-01

    Methods such as the molarity of ethanol droplet (MED) test and water drop penetration test (WDPT) are commonly used to measure soil wettability because these tests are quick and easy to perform. However, they are not without limitations. This thesis proposes using a low-field NMR relaxometer as an alternative method of assessing soil wettability. This instrument is able to discriminate surface bound fluid from bulk fluid Fluid bound to the surface relaxes quickly and produces signal amplitude peaks at low transverse relaxation time (T 2 ) values. Bulk fluid , on the other hand, relaxes much more slowly and signal amplitude peaks consequently appear at higher T 2 values. An extensive experimental program was designed to test the above hypothesis. Hundreds of NMR measurements were performed on clays, humic acids, fulvic acids, clean sands, sands coated with organic matter, wettable soils and water-repellent soils exposed to distilled water and kerosene. The results confirm the hypothesis and show clearly that NMR does detect preferentially water-wet and water-repellent samples. The differences in the solid-fluid interactions between water and unconsolidated porous media with varying wetting preferences also allow for the use of low-field NMR to detect wettability alteration and to monitor fluid uptake in unconsolidated porous media. The advantages of using this tool include obtaining reproducible results quickly, using only small amounts of sample for analysis, and calculating the mass of water without performing a mass balance calculation. (author)

  17. Visualization and simulation of density driven convection in porous media using magnetic resonance imaging

    Science.gov (United States)

    Montague, James A.; Pinder, George F.; Gonyea, Jay V.; Hipko, Scott; Watts, Richard

    2018-05-01

    Magnetic resonance imaging is used to observe solute transport in a 40 cm long, 26 cm diameter sand column that contained a central core of low permeability silica surrounded by higher permeability well-sorted sand. Low concentrations (2.9 g/L) of Magnevist, a gadolinium based contrast agent, produce density driven convection within the column when it starts in an unstable state. The unstable state, for this experiment, exists when higher density contrast agent is present above the lower density water. We implement a numerical model in OpenFOAM to reproduce the observed fluid flow and transport from a density difference of 0.3%. The experimental results demonstrate the usefulness of magnetic resonance imaging in observing three-dimensional gravity-driven convective-dispersive transport behaviors in medium scale experiments.

  18. Bimetallic magnetic PtPd-nanoparticles as efficient catalyst for PAH removal from liquid media

    Science.gov (United States)

    Zanato, A. F. S.; Silva, V. C.; Lima, D. A.; Jacinto, M. J.

    2017-11-01

    Monometallic Pd- and bimetallic PtPd-nanoparticles supported on a mesoporous magnetic magnetite@silica matrix resembling a core-shell structure (Fe3O4@mSiO2) have been fabricated. The material was characterized by transmission electron microscope (TEM), high-angle annular dark field-scanning transmission electron microscopy (HAADF-STEM), X-ray photoelectron spectra (XPS), energy dispersive spectroscopy (EDS) and inductively coupled plasma mass spectrometry (ICP-MS). The catalysts were applied in the removal of anthracene from liquid phase via catalytic hydrogenation. It was found that anthracene as a model compound could be completely converted into the partially hydrogenated species by the monometallic and bimetallic solids. However, during the recycling study the bimetallic material (Fe3O4@mSiO2PtPd-) showed an enhanced activity towards anthracene removal compared with the monometallic materials. A single portion of the PtPd-based catalyst can be used up to 11 times in the hydrogenation of anthracene under mild conditions (6 atm of H2, 75 °C, 20 min). Thanks to the presence of a dense magnetic core, the catalysts were capable of responding to an applied external magnetic field and once the reaction was completed, catalyst/product separation was straightforward.

  19. Paramagnetic contrast media for magnetic resonance imaging of the central nervous system

    International Nuclear Information System (INIS)

    McNamara, M.T.

    1987-01-01

    Presently, a variety of radiofrequency (RF) and magnetic field gradient pulse sequences is used to manipulate magnetic resonance (MR) image contrast. Such manipulation may be performed by altering the RF pulse sequence repetition time (TR), the spin-echo delay time (TE), the inversion-delay time (TI), and the flip angle. The detection and characterization of a lesion or structure may thus be optimized. Although such contrast manipulation is noninvasive, magnetic resonance imaging (MRI) still suffers somewhat from lack of specificity. Also, the use of multiple imaging sequences to locate and characterize a lesion may prolong the imaging time and, thus, might place an economic burden on the system. Paramagnetic pharmaceuticals offer promise in this regard. They shorten tissue relaxation times, thus permitting the use of shorter imaging parameters, and in some circumstances, may obviate additional and more time-consuming pulse sequences. Paramagnetics could expand the sensitivity and specificity of MRI and provide functional information with regard to tissue perfusion, tissue viability, and blood-brain barrier integrity

  20. Nuclear magnetic resonance characterization of the stationary dynamics of partially saturated media during steady-state infiltration flow

    Science.gov (United States)

    Rassi, Erik M.; Codd, Sarah L.; Seymour, Joseph D.

    2011-01-01

    Flow in porous media and the resultant hydrodynamics are important in fields including but not limited to the hydrology, chemical, medical and petroleum industries. The observation and understanding of the hydrodynamics in porous media are critical to the design and optimal utilization of porous media, such as those seen in trickle-bed reactors, medical filters, subsurface flows and carbon sequestration. Magnetic resonance (MR) provides for a non-invasive technique that can probe the hydrodynamics on pore and bulk scale lengths; many previous works have characterized fully saturated porous media, while rapid MR imaging (MRI) methods in particular have previously been applied to partially saturated flows. We present time- and ensemble-averaged MR measurements to observe the effects on a bead pack partially saturated with air under flowing water conditions. The 10 mm internal diameter bead pack was filled with 100 μm borosilicate glass beads. Air was injected into the bead pack as water flowed simultaneously through the sample at 25 ml h-1. The initial partially saturated state was characterized with MRI density maps, free induction decay (FID) experiments, propagators and velocity maps before the water flow rate was increased incrementally from 25 to 500 ml h-1. After the maximum flow rate of 500 ml h-1, the MRI density maps, FID experiments, propagators and velocity maps were repeated and compared to the data taken before the maximum flow rate. This work shows that a partially saturated single-phase flow has global flow dynamics that return to characteristic flow statistics once a steady-state high flow rate has been reached. This high flow rate pushed out a significant amount of the air in the bead pack and caused the return of a preferential flow pattern. Velocity maps indicated that local flow statistics were not the same for the before and after blow out conditions. It has been suggested and shown previously that a flow pattern can return to

  1. Nuclear magnetic resonance characterization of the stationary dynamics of partially saturated media during steady-state infiltration flow

    International Nuclear Information System (INIS)

    Rassi, Erik M; Codd, Sarah L; Seymour, Joseph D

    2011-01-01

    Flow in porous media and the resultant hydrodynamics are important in fields including but not limited to the hydrology, chemical, medical and petroleum industries. The observation and understanding of the hydrodynamics in porous media are critical to the design and optimal utilization of porous media, such as those seen in trickle-bed reactors, medical filters, subsurface flows and carbon sequestration. Magnetic resonance (MR) provides for a non-invasive technique that can probe the hydrodynamics on pore and bulk scale lengths; many previous works have characterized fully saturated porous media, while rapid MR imaging (MRI) methods in particular have previously been applied to partially saturated flows. We present time- and ensemble-averaged MR measurements to observe the effects on a bead pack partially saturated with air under flowing water conditions. The 10 mm internal diameter bead pack was filled with 100 μm borosilicate glass beads. Air was injected into the bead pack as water flowed simultaneously through the sample at 25 ml h -1 . The initial partially saturated state was characterized with MRI density maps, free induction decay (FID) experiments, propagators and velocity maps before the water flow rate was increased incrementally from 25 to 500 ml h -1 . After the maximum flow rate of 500 ml h -1 , the MRI density maps, FID experiments, propagators and velocity maps were repeated and compared to the data taken before the maximum flow rate. This work shows that a partially saturated single-phase flow has global flow dynamics that return to characteristic flow statistics once a steady-state high flow rate has been reached. This high flow rate pushed out a significant amount of the air in the bead pack and caused the return of a preferential flow pattern. Velocity maps indicated that local flow statistics were not the same for the before and after blow out conditions. It has been suggested and shown previously that a flow pattern can return to similar

  2. The Private Communications of Magnetic Recording under Socialism (Retrospective Disco Analysis

    Directory of Open Access Journals (Sweden)

    Oleg Vladimir Sineokij

    2013-07-01

    Full Text Available The article analyzes the formation and development of a general model of rare sound records in the structure of institutions of a social communication. The author considers psychocomminicative features of the filophone communication as a special type of interaction in the field of entertainment. The author studied the causes and conditions of a tape subculture in the USSR. It is observed the dynamics of the disco-communication in limited information conditions from socialism till modern high-tech conditions.At the end of the article the author argues based achievements in the field of advanced technology systems, innovation revival in the industry of music-record. Hence, using innovative approaches in the study, the author sets out the basic concept of recording popular music as a special information and legal institution, in retrospect, the theory and practice of the future needs in the information society.

  3. Contribution to the study of nuclear resonance in magnetic media (1963)

    International Nuclear Information System (INIS)

    Hartmann-Boutron, F.

    1963-06-01

    An attempt is made to interpret the results of nuclear magnetic resonance experiments made by various workers on ferro and ferrimagnetic compounds of the iron group. The problems encountered are the following: effects of the dipolar fields and the hyperfine structure anisotropy; signal intensity; frequency pulling due to the Suhl-Nakamura interaction between nuclear spins ; nuclear relaxation and ferrimagnetic resonance in single domain samples of impure YIG; nuclear relaxation in the Bloch walls of insulators. The results of our calculations are generally in good agreement with experiment. (author) [fr

  4. A detailed paleomagnetic and rock-magnetic investigation of the Matuyama-Bruhnes geomagnetic reversal recorded in tephra-paleosol sequence of Tlaxcala(Central Mexico

    Directory of Open Access Journals (Sweden)

    Ana Maria Soler-Arechalde

    2015-04-01

    Full Text Available Geomagnetic reversals are global phenomena, for about 50 years the paleomagnetists attempted to acquire as many detailed records as possible using the magnetic memory of sediments and lava flows. Yet, transitional field behavior remains poorly characterized largely because of sporadic aspect of volcanic eruptions. In some specific cases, paleosols such as those developed from alluvial or aeolian sediments, may also record the variations of the Geomagnetic Field across the polarity changes. Here, we report a detailed paleomagnetic and rock-magnetic investigation on some radiometrically dated chromic luvisols located in Central Mexico carrying detrital or chemical remanent magnetization. The research was developed in order i to demonstrate the primary origin of the magnetic remanence and ii to show that paleosoils are good candidates to provide a high resolution record of the behavior of geomagnetic field during reversals. The lower part of the paleosoil sequence shows a clearly defined reverse polarity magnetization followed by geomagnetically unstable transitional field and ended by normal polarity remanence. Our AMS and rock magnetic data suggest that magnetization is acquired during the initial stage of soil formation in context of active volcanic activity since magnetic fabric is essentially sedimentary and reverse and normal polarity paleodirections are almost antipodal. Titanomagnetites are identified as main magnetic carriers of rock-magnetic measurements including thermomagnetics and hysteresis cycles. We propose that the transition recorded in this study correspond to the B-M boundary, considering the K-Ar datings available at the sequence bottom and that the chromic luvisols are potentially good recorders of the paleosecular variation. The identification of the B-M boundary within the studied sequence has fundamental significance for improving the chronological scale of Tlaxcala paleosol-sedimentary sequence and its correlation with the

  5. An integrated natural remanent magnetization acquisition model for the Matuyama-Brunhes reversal recorded by the Chinese loess

    Science.gov (United States)

    Jin, Chunsheng; Liu, Qingsong; Hu, Pengxiang; Jiang, Zhaoxia; Li, Cange; Han, Peng; Yang, Huihui; Liang, Wentian

    2016-08-01

    Geomagnetic polarity reversal boundaries are key isochronous chronological controls for the long Chinese loess sequences, and further facilitate paleoclimatic correlation between Chinese loess and marine sediments. However, owing to complexity of postdepositional remanent magnetization (pDRM) acquisition processes related to variable dust sedimentary environments on the Chinese Loess Plateau (CLP), there is a long-standing dispute concerning the downward shift of the pDRM recorded in Chinese loess. In this study, after careful stratigraphic correlation of representative climatic tie points and the Matuyama-Brunhes boundaries (MBB) in the Xifeng, Luochuan, and Mangshan loess sections with different pedogenic environments, the downward shift of the pDRM is semiquantitatively estimated and the acquisition model for the loess natural remanent magnetization (NRM) is discussed. The measured MB transition zone has been affected by the surficial mixing layer (SML) and remagnetization. Paleoprecipitation is suggested to be the dominant factor controlling the pDRM acquisition processes. Rainfall-controlled leaching would restrict the efficiency of the characterized remanent magnetization carriers aligning along the ancient geomagnetic field. We conclude that the MBB in the central CLP with moderate paleoprecipitation could be considered as an isochronous chronological control after moderate upward adjustment. A convincing case can then be made to correlate L8/S8 to MIS 18/19.

  6. Evidence for cosmic ray modulation in temperature records from the South Atlantic Magnetic Anomaly region

    Energy Technology Data Exchange (ETDEWEB)

    Frigo, E. [Sao Paulo Univ. (Brazil). Dept. de Geofisica; Federal do Pampa Univ., Cacapava do Sul (Brazil); Pacca, I.G. [Sao Paulo Univ. (Brazil). Dept. de Geofisica; Pereira-Filho, A.J. [Sao Paulo Univ. (Brazil). Dept. de Ciencias Atmosfericas; Rampelloto, P.H. [Federal do Pampa Univ., Sao Gabriel (Brazil); Rigozo, N.R. [Instituto Nacional de Pesquisas Espaciais, Sao Jose dos Campos (Brazil). Div. de Geofisica Espacial

    2013-11-01

    Possible direct or indirect climatic effects related to solar variability and El Nino-Southern Oscillation (ENSO) were investigated in the southern Brazil region by means of the annual mean temperatures from four weather stations 2 degrees of latitude apart over the South Atlantic Magnetic Anomaly (SAMA) region. Four maximum temperature peaks are evident at all stations in 1940, 1958, 1977 and 2002. A spectral analysis indicates the occurrence of periodicities between 2 and 7 yr, most likely associated with ENSO, and periodicities of approximately 11 and 22 yr, normally associated with solar variability. Cross-wavelet analysis indicated that the signal associated with the 22 yr solar magnetic cycle was more persistent in the last decades, while the 11 yr sunspot cycle and ENSO periodicities were intermittent. Phase-angle analysis revealed that temperature variations and the 22 yr solar cycle were in anti-phase near the SAMA center. Results show an indirect indication of possible relationships between the variability of galactic cosmic rays and climate change on a regional scale.

  7. Multiscale Pore Throat Network Reconstruction of Tight Porous Media Constrained by Mercury Intrusion Capillary Pressure and Nuclear Magnetic Resonance Measurements

    Science.gov (United States)

    Xu, R.; Prodanovic, M.

    2017-12-01

    Due to the low porosity and permeability of tight porous media, hydrocarbon productivity strongly depends on the pore structure. Effective characterization of pore/throat sizes and reconstruction of their connectivity in tight porous media remains challenging. Having a representative pore throat network, however, is valuable for calculation of other petrophysical properties such as permeability, which is time-consuming and costly to obtain by experimental measurements. Due to a wide range of length scales encountered, a combination of experimental methods is usually required to obtain a comprehensive picture of the pore-body and pore-throat size distributions. In this work, we combine mercury intrusion capillary pressure (MICP) and nuclear magnetic resonance (NMR) measurements by percolation theory to derive pore-body size distribution, following the work by Daigle et al. (2015). However, in their work, the actual pore-throat sizes and the distribution of coordination numbers are not well-defined. To compensate for that, we build a 3D unstructured two-scale pore throat network model initialized by the measured porosity and the calculated pore-body size distributions, with a tunable pore-throat size and coordination number distribution, which we further determine by matching the capillary pressure vs. saturation curve from MICP measurement, based on the fact that the mercury intrusion process is controlled by both the pore/throat size distributions and the connectivity of the pore system. We validate our model by characterizing several core samples from tight Middle East carbonate, and use the network model to predict the apparent permeability of the samples under single phase fluid flow condition. Results show that the permeability we get is in reasonable agreement with the Coreval experimental measurements. The pore throat network we get can be used to further calculate relative permeability curves and simulate multiphase flow behavior, which will provide valuable

  8. A Nanoscale Plasma Etching Process for Pole Tip Recession of Perpendicular Recording Magnetic Head

    OpenAIRE

    LIU, Shoubin; HE, Dayao

    2017-01-01

    The pole tip of perpendicular recording head is constructed in a stacked structure with materials of NiCoFe, NiFe, Al2O3 and AlTiC. The surfaces of different materials are set at different heights below the air-bearing surface of slider. This paper presented a plasma dry etching process for Pole Tip Recession (PTR) based on an ion beam etching system. Ar and O2 mixed plasma at small incident angles have a high removal rate to the nonmagnetic material. It was utilised to etch the reference sur...

  9. Absolute paleointensities during a mid Miocene reversal of the Earth's magnetic field recorded on Gran Canaria (Canary Islands)

    Science.gov (United States)

    Leonhardt, R.; Soffel, H. C.

    2001-12-01

    An extensive paleointensity study was carried out on an approximately 14.1 Myr old reverse to normal transition of the geomagnetic field. One hundred eighty-eight samples from a mid Miocene volcanic sequence on Gran Canaria (Canary Islands) were subjected to Thellier-type paleointensity determinations. Samples for paleointensity experiments were selected on the basis of high Curie temperatures, low viscosity indexes, and limited variations of the remanence-carrying magnetic content during thermal treatment. A modified Thellier technique, which facilitates the recognition of MD tails and the formation of new magnetic remanences with higher blocking temperatures than the actual heating step, was used on the majority of the samples. The application of this technique proved to be very successful and we obtained reliable paleointensity results for 35% of the 87 sampled lava flows. In general, the intensity of the reversed and normal magnetized parts of the sequence, before and after the transition, is lower than the field intensity expected for the mid Miocene. This observation is very likely related to a long term reduction of the field close to transitions. The mean field intensity after the reversal ( ~ 17 μ T) is about twice the value of that recorded in the rocks prior to the reversal. This observation points at a fast recovery of the dipolar structure of the field after this reversal. Very low paleointensities with values < 5 μ T were obtained during an excursion, preceding the actual transition, and also close to significant changes of the local field directions during the reversal. This is interpreted as non-dipolar components becoming dominant for short periods and provoking a rapid change of local field directions. During the transition 15 successive lava flows recorded similar local field directions corresponding to a cluster of virtual geomagnetic poles close to South America. Chronologically, within this cluster the paleointensity increases from about 9

  10. Oral contrast media for the magnetic resonance tomography of the abdomen. Pt. 3

    International Nuclear Information System (INIS)

    Claussen, C.; Kornmesser, W.; Laniado, M.; Kaminsky, S.; Hamm, B.; Felix, R.; Klinikum Steglitz, Berlin

    1988-01-01

    32 patients with abdominal tumours or inflammatory abdominal diseases were examined by MRI (0.5 T) prior to and after oral administration of gadolinium-DTPA (Gd-DTPA). T 1 - and T 2 -weighted sequences were employed. 10 ml/kg body weight of a Gd-DTPA formulation were administered (1.0 mmol/l, 1.5 g mannitol/l). Gd-DTPA provided markedly hyperintensive opacification of the gastro-intestinal tract. In 19 of 32 studies Gd-DTPA-enhanced scans showed improved delineation of abdominal pathologies. In most cases Gd-DTPA-enhanced T 1 -weighted multi-slice gradient echo images provided the most useful diagnostic result. Meteorism and diarrhoe were recorded in 13 patients. (orig.) [de

  11. Cine Magnetic Resonance Imaging of the Small Bowel: Comparison of Different Oral Contrast Media

    International Nuclear Information System (INIS)

    Asbach, P.; Breitwieser, C.; Diederichs, G.; Eisele, S.; Kivelitz, D.; Taupitz, M.; Zeitz, M.; Hamm, B.; Klessen, C.

    2006-01-01

    Purpose: To evaluate several substances regarding small bowel distension and contrast on balanced steady-state free precession (bSSFP) cine magnetic resonance (MR) images. Material and Methods: Luminal contrast was evaluated in 24 volunteers after oral application of two different contrast agent groups leading to either bright lumen (pineapple, blueberry juice) or dark lumen (tap water, orange juice) on T1-weighted images. Bowel distension was evaluated in 30 patients ingesting either methylcellulose or mannitol solution for limiting intestinal absorption. Fifteen patients with duodeno-jejunal intubation served as the control. Quantitative evaluation included measurement of luminal signal intensities and diameters of four bowel segments, qualitative evaluation assessed luminal contrast and distension on a five-point scale. Results: Quantitative and qualitative evaluation of the four contrast agents revealed no significant differences regarding luminal contrast on bSSFP images. Quantitative evaluation revealed significantly lower (P<0.05) small bowel distension for three out of four segments (qualitative evaluation: two out of four segments) for methylcellulose in comparison to the control. Mannitol was found to be equal to the control. Conclusion: Oral ingestion of tap water or orange juice in combination with mannitol is recommended for cine MR imaging of the small bowel regarding luminal contrast and small bowel distension on bSSFP sequences

  12. Interactive neonatal gastrointestinal magnetic resonance imaging using fruit juice as an oral contrast media

    International Nuclear Information System (INIS)

    Arthurs, Owen J; Graves, Martin J; Edwards, Andrea D; Joubert, Ilse; Set, Pat AK; Lomas, David J

    2014-01-01

    The objective was to evaluate the use of fruit juice with an interactive inversion recovery (IR) MR pulse sequence to visualise the gastrointestinal tract. We investigated the relaxation properties of 12 different natural fruit juices in vitro, to identify which could be used as oral contrast. We then describe our initial experience using an interactive MR pulse sequence to allow optimal visualisation after administering pineapple juice orally, and suppressing pre-existing bowel fluid contents, with variable TI in three adult and one child volunteer. Pineapple juice (PJ) had both the shortest T 1 (243 ms) and shortest T 2 (48 ms) of the fruit juices tested. Optimal signal differentiation between pre-existing bowel contents and oral PJ administration was obtained with TIs of between 900 and 1100 ms. The use of an inversion recovery preparation allowed long T 1 pre-existing bowel contents to be suppressed whilst the short T 1 of fruit juice acts as a positive contrast medium. Pineapple juice could be used as oral contrast agent for neonatal gastrointestinal magnetic resonance imaging

  13. Cine Magnetic Resonance Imaging of the Small Bowel: Comparison of Different Oral Contrast Media

    Energy Technology Data Exchange (ETDEWEB)

    Asbach, P.; Breitwieser, C.; Diederichs, G.; Eisele, S.; Kivelitz, D.; Taupitz, M.; Zeitz, M.; Hamm, B.; Klessen, C. [Charite - Universitatsmedizin Berlin, Charite Campus Mitte, Berlin (Germany). Dept. of Radiology

    2006-11-15

    Purpose: To evaluate several substances regarding small bowel distension and contrast on balanced steady-state free precession (bSSFP) cine magnetic resonance (MR) images. Material and Methods: Luminal contrast was evaluated in 24 volunteers after oral application of two different contrast agent groups leading to either bright lumen (pineapple, blueberry juice) or dark lumen (tap water, orange juice) on T1-weighted images. Bowel distension was evaluated in 30 patients ingesting either methylcellulose or mannitol solution for limiting intestinal absorption. Fifteen patients with duodeno-jejunal intubation served as the control. Quantitative evaluation included measurement of luminal signal intensities and diameters of four bowel segments, qualitative evaluation assessed luminal contrast and distension on a five-point scale. Results: Quantitative and qualitative evaluation of the four contrast agents revealed no significant differences regarding luminal contrast on bSSFP images. Quantitative evaluation revealed significantly lower (P<0.05) small bowel distension for three out of four segments (qualitative evaluation: two out of four segments) for methylcellulose in comparison to the control. Mannitol was found to be equal to the control. Conclusion: Oral ingestion of tap water or orange juice in combination with mannitol is recommended for cine MR imaging of the small bowel regarding luminal contrast and small bowel distension on bSSFP sequences.

  14. Magnetic properties of Co/Pt-Pd multilayer thin film media

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, N.; Igarashi, S.; Fujita, F.; Koike, K.; Kato, H. [Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Kirino, F. [National University of Fine Arts and Music, Taitou-ku, Tokyo 110-8714 (Japan)

    2007-12-15

    We investigated the dependence of magnetic properties for Co/Pt{sub 100-x}Pd{sub x} multilayer thin films on the concentration in the Pt-Pd alloy layers. Perpendicular magneto anisotropy constant K {sub p} increases with increasing Pt concentration in the Pt-Pd layer, since the interface anisotropy between the Co and the Pt-Pd layers is enhanced by the increase of the Pt concentration. The Curie temperature and the temperature dependence of K{sub p} for the specimens increase with increasing the amount of Pt in the Pt-Pd layer. These results may indicate that the lattice distortion of the Co layer caused by the interface from the Pt-Pd layer becomes larger and the increase of the distortion enhances the interface anisotropy, since the lattice misfit between the Pt-Pd and the Co increases with increasing the Pt concentration. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Magnetic nanoparticle assemblies

    CERN Document Server

    Trohidou, Kalliopi N

    2014-01-01

    Magnetic nanoparticles with diameters in the range of a few nanometers are today at the cutting edge of modern technology and innovation because of their use in numerous applications ranging from engineering to biomedicine. A great deal of scientific interest has been focused on the functionalization of magnetic nanoparticle assemblies. The understanding of interparticle interactions is necessary to clarify the physics of these assemblies and their use in the development of high-performance magnetic materials. This book reviews prominent research studies on the static and dynamic magnetic properties of nanoparticle assemblies, gathering together experimental and computational techniques in an effort to reveal their optimized magnetic properties for biomedical use and as ultra-high magnetic recording media.

  16. The magnetic structure and palaeomagnetic recording fidelity of sub-micron greigite (Fe3S4)

    Science.gov (United States)

    Valdez-Grijalva, Miguel A.; Nagy, Lesleis; Muxworthy, Adrian R.; Williams, Wyn; Fabian, Karl

    2018-02-01

    We present the results of a finite-element micromagnetic model of 30nm to 300nm greigite (Fe3S4) grains with a variety of equant morphologies. This grain size range covers the magnetic single-domain (SD) to pseudo single-domain (PSD) transition, and possibly also the PSD to multi-domain (MD) transition. The SD-PSD threshold d0 is determined to be 50nm ≤d0 ≤ 56nm depending on grain shape. The nudged elastic-band method was used to determine the room temperature energy barriers between stable states and thus the blocking volumes. It is found that, in the absence of interparticle magnetostatic interactions, the magnetisation of equant SD greigite is not stable on a geological scale and only PSD grains ≥ 70nm can be expected to carry a stable magnetisation over billion-year timescales, i.e., all non-interacting SD particles are essentially superparamagnetic. We further identify a mechanism for the PSD to multi-domain (MD) transition, which is of a continuous nature from PSD nucleation up to 300nm, when structures typical of MD behaviour like closure domains begin to form.

  17. The transition from longitudinal to perpendicular recording

    International Nuclear Information System (INIS)

    Richter, H J

    2007-01-01

    After more than 30 years of research, hard disk drives using perpendicular recording are finally commercially available. This review is a follow-up of a review written in 1999 and addresses the basic physics of perpendicular recording with special emphasis on the read and the write process and the magnetic aspects of the recording media. The paper also surveys various technical difficulties which prevented an earlier implementation of perpendicular recording. The paper closes with a short overview of alternative technologies that allow even higher storage densities. (topical review)

  18. Read/write performance of perpendicular double-layered cylindrical media

    International Nuclear Information System (INIS)

    Yamada, H.; Shimatsu, T.; Watanabe, I.; Tsuchiyama, R.; Aoi, H.; Muraoka, H.; Nakamura, Y.

    2005-01-01

    A cylindrical magnetic storage system using perpendicular double-layered media has been developed. CoCrTa/CoZrNb deposited on a rotating cylindrical substrate shows perpendicular anisotropy and magnetic properties, which have almost the same characteristics as conventional disk-media. The fundamental read/write characteristics of perpendicular double-layered cylindrical media were measured using a single-pole-type (SPT) writer with a sliding-contact-type slider and a merged giant magneto-resistive (GMR) reader with a one-pad-type slider designed for use with cylindrical media. Preliminary studies for improving the characteristics of the recording layer are also described

  19. Observation of spatial splitting of a polarized neutron beam as it is refracted on the interface of two magnetically non-collinear media

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Kozhevnikov, S.V.; Nikitenko, Yu.V.; Fredrikze, H.; Rekveldt, M.Th.; Schreiber, J.

    1998-01-01

    In the conducted experimental investigation of neutron refraction on the interface of two magnetically non-collinear media spatial splitting of a polarized neutron beam was observed. The beam of neutrons initially in the spin state '+' or '-' splits into two beams of neutrons in the states '+' and '-'. All four split beams have different spatial positions. The reported phenomenon has been observed for the first time

  20. Rock Magnetic Properties, Paleosecular Variation Record and Relative Paleointensity Stack between 11 and 21 14C kyr B.P. From Sediment Cores, Lake Moreno (Argentina)

    Science.gov (United States)

    Gogorza, C. S.; Irurzun, M. A.; Lirio, J. M.; Nunez, H.; Chaparro, M. A.; Sinito, A. M.

    2008-05-01

    We conducted a detailed study of natural remanence and rock magnetic properties on sediments cores from lake Moreno (South-Western Argentina). Based on these measurements, we constructed a paleosecular variation (PSV) record (Irurzun et al., 2008) and a relative paleointensity stack for the period 11-21 14C. The Declination and Inclination logs of the characteristic remanent magnetization for the cores as function of shortened depth are obtained. The data from all cores were combined to obtain a composite record using the Fisher method. Comparison between stacked inclination and declination records of lake Moreno and results obtained in previous works, lake Escondido (Gogorza et al., 1999; Gogorza et al., 2002) and lake El Trébol (Irurzun et al., 2008), shows good agreement. This agreement made possible to transform the stacked curves into time series that spans the interval 11 and 21 14C kyr B.P. Rock magnetic properties of the sediments cores showed uniform magnetic mineralogy and grain size, suggesting that they were suitable for relative paleointensity studies. The remanent magnetization at 20mT (NRM20mT) was normalized using the anhysteric remanent magnetization at 20mT (ARM20mT), the saturation of the isothermal remanent magnetization at 20mT (SIRM20mT) and the low field magnetic susceptibility {k}. Coherence analysis showed that the normalized records were not affected by local environmental conditions. The recorded pseudo-Thellier paleointensity was compared with records obtained from conventional normalizing methods. Comparing the paleointensity curves with others obtained previously in other lakes in the area has allowed us to reach reliable conclusions about centennial-scale features. References: Gogorza, C.S.G., Sinito, A.M., Di Tommaso, I., Vilas, J.F., Creer, K., Núnez, H. Holocene Geomagnetic Secular Variations Recorded by Sediments from Escondido lake (South Argentina). Earth, Planets and Space, V51(2), 93- 106. 1999. Gogorza, C.S.G., Sinito, A

  1. Safety and reliability of the insertable Reveal XT recorder in patients undergoing 3 Tesla brain magnetic resonance imaging.

    Science.gov (United States)

    Haeusler, Karl Georg; Koch, Lydia; Ueberreiter, Juliane; Coban, Nalan; Safak, Erdal; Kunze, Claudia; Villringer, Kersten; Endres, Matthias; Schultheiss, Heinz-Peter; Fiebach, Jochen B; Schirdewan, Alexander

    2011-03-01

    Up to now there is little evidence about the safety and reliability of insertable cardiac monitors (ICMs) in patients undergoing magnetic resonance imaging (MRI). The purpose of this prospective single-center study (MACPAF; clinicaltrials.govNCT01061931), which we are currently performing, was to evaluate these issues for the ICM Reveal XT at a 3 Tesla MRI scanner in patients undergoing serial brain MRI. We present an interim analysis including 62 brain MRI examinations in 24 patients with paroxysmal atrial fibrillation bearing the Reveal XT. All patients were interviewed for potential ICM-associated clinical symptoms during and after MRI examination. According to the study protocol, data from the Reveal XT were transmitted before and after the MRI examination. All patients were clinically asymptomatic during the MRI procedure. Moreover, the reliability (ability to detect signals, battery status) of the Reveal XT was unaffected, except for one MRI-induced artifact that was recorded by the ICM, mimicking a narrow complex tachycardia, as similarly recorded in a further study patient bearing the forerunner ICM Reveal DX. No loss of ICM data was observed after the MRI examination. The 3 Tesla brain MRI scanning is safe for patients bearing the ICM Reveal XT and does not alloy reliability of the Reveal XT itself. MRI-induced artifacts occur rarely but have to be taken into account. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  2. Removal of CdTe in acidic media by magnetic ion-exchange resin: A potential recycling methodology for cadmium telluride photovoltaic waste

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Teng, E-mail: zhangteng@mail.iee.ac.cn; Dong, Zebin; Qu, Fei; Ding, Fazhu; Peng, Xingyu; Wang, Hongyan; Gu, Hongwei

    2014-08-30

    Highlights: • Sulfonated magnetic microsphere was prepared as one strong acid cation-exchange resin. • Cd and Te can be removed directly from the highly acidic leaching solution of CdTe. • Good chemical stability, fast adsorbing rate and quick magnetic separation in strong acidic media. • A potential path for recycling CdTe photovoltaic waste. - Abstract: Sulfonated magnetic microspheres (PSt-DVB-SNa MPs) have been successfully prepared as adsorbents via an aqueous suspension polymerization of styrene-divinylbenzene and a sulfonation reaction successively. The resulting adsorbents were confirmed by means of Fourier transform infrared spectra (FT-IR), X-ray diffraction (XRD), transmission electron microscope (TEM), scanning electron microscope equipped with an energy dispersive spectrometer (SEM-EDS) and vibrating sample magnetometer (VSM). The leaching process of CdTe was optimized, and the removal efficiency of Cd and Te from the leaching solution was investigated. The adsorbents could directly remove all cations of Cd and Te from a highly acidic leaching solution of CdTe. The adsorption process for Cd and Te reached equilibrium in a few minutes and this process highly depended on the dosage of adsorbents and the affinity of sulfonate groups with cations. Because of its good adsorption capacity in strong acidic media, high adsorbing rate, and efficient magnetic separation from the solution, PSt-DVB-SNa MPs is expected to be an ideal material for the recycling of CdTe photovoltaic waste.

  3. Anomalous solute transport in saturated porous media: Relating transport model parameters to electrical and nuclear magnetic resonance properties

    Science.gov (United States)

    Swanson, Ryan D; Binley, Andrew; Keating, Kristina; France, Samantha; Osterman, Gordon; Day-Lewis, Frederick D.; Singha, Kamini

    2015-01-01

    The advection-dispersion equation (ADE) fails to describe commonly observed non-Fickian solute transport in saturated porous media, necessitating the use of other models such as the dual-domain mass-transfer (DDMT) model. DDMT model parameters are commonly calibrated via curve fitting, providing little insight into the relation between effective parameters and physical properties of the medium. There is a clear need for material characterization techniques that can provide insight into the geometry and connectedness of pore spaces related to transport model parameters. Here, we consider proton nuclear magnetic resonance (NMR), direct-current (DC) resistivity, and complex conductivity (CC) measurements for this purpose, and assess these methods using glass beads as a control and two different samples of the zeolite clinoptilolite, a material that demonstrates non-Fickian transport due to intragranular porosity. We estimate DDMT parameters via calibration of a transport model to column-scale solute tracer tests, and compare NMR, DC resistivity, CC results, which reveal that grain size alone does not control transport properties and measured geophysical parameters; rather, volume and arrangement of the pore space play important roles. NMR cannot provide estimates of more-mobile and less-mobile pore volumes in the absence of tracer tests because these estimates depend critically on the selection of a material-dependent and flow-dependent cutoff time. Increased electrical connectedness from DC resistivity measurements are associated with greater mobile pore space determined from transport model calibration. CC was hypothesized to be related to length scales of mass transfer, but the CC response is unrelated to DDMT.

  4. Magnets

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    A magnet pole piece for an NMR imaging magnet is made of a plurality of magnetic wires with one end of each wire held in a non-magnetic spacer, the other ends of the wires being brought to a pinch, and connected to a magnetic core. The wires may be embedded in a synthetic resin and the magnetisation and uniformity thereof can be varied by adjusting the density of the wires at the spacer which forms the pole piece. (author)

  5. Time-Transgressive Nature of the Magnetic Susceptibility Record across the Chinese Loess Plateau at the Pleistocene/Holocene Transition

    Science.gov (United States)

    Dong, Yajie; Wu, Naiqin; Li, Fengjiang; Huang, Linpei; Wen, Wenwen

    2015-01-01

    The loess stratigraphic boundary at the Pleistocene/Holocene transition defined by the magnetic susceptibility (MS) has previously been assumed to be synchronous with the Marine Isotope Stage (MIS) 2/1 boundary, and approximately time-synchronous at different sections across the Chinese Loess Plateau (CLP). However, although this assumption has been used as a basis for proxy-age model of Chinese loess deposits, it has rarely been tested by using absolute dating methods. In this study, we applied a single-aliquot regenerative-dose (SAR) protocol to the 45–63 μm quartz grain-size fraction to derive luminescence ages for the last glacial and Holocene sections of three loess sections on a transect from southeast to northwest across the CLP. Based on the 33 closely spaced optically stimulated luminescence (OSL) samples from the three sections, OSL chronologies were established using a polynomial curve fit at each section. Based on the OSL chronology, the timing of the Pleistocene/Holocene boundary, as defined by rapid changes in MS values, is dated at ~10.5 ka, 8.5 ka and 7.5 ka in the Yaoxian section, Jingchuan and Huanxian sections respectively. These results are clearly inconsistent with the MIS 2/1 boundary age of 12.05 ka, and therefore we conclude that the automatic correlation of the Pleistocene/Holocene transition, as inferred from the MS record, with the MIS 2/1 boundary is incorrect. The results clearly demonstrate that the marked changes in MS along the southeast to northwest transect are time-transgressive among the different sites, with the timing of significant paleosol development as indicated by the MS record being delayed by 3–4 ka in the northwest compared to the southeast. Our results suggest that this asynchronous paleosol development during the last deglacial was caused by the delayed arrival of the summer monsoon in the northwest CLP compared to the southeast. PMID:26186443

  6. Time-Transgressive Nature of the Magnetic Susceptibility Record across the Chinese Loess Plateau at the Pleistocene/Holocene Transition.

    Directory of Open Access Journals (Sweden)

    Yajie Dong

    Full Text Available The loess stratigraphic boundary at the Pleistocene/Holocene transition defined by the magnetic susceptibility (MS has previously been assumed to be synchronous with the Marine Isotope Stage (MIS 2/1 boundary, and approximately time-synchronous at different sections across the Chinese Loess Plateau (CLP. However, although this assumption has been used as a basis for proxy-age model of Chinese loess deposits, it has rarely been tested by using absolute dating methods. In this study, we applied a single-aliquot regenerative-dose (SAR protocol to the 45-63 μm quartz grain-size fraction to derive luminescence ages for the last glacial and Holocene sections of three loess sections on a transect from southeast to northwest across the CLP. Based on the 33 closely spaced optically stimulated luminescence (OSL samples from the three sections, OSL chronologies were established using a polynomial curve fit at each section. Based on the OSL chronology, the timing of the Pleistocene/Holocene boundary, as defined by rapid changes in MS values, is dated at ~10.5 ka, 8.5 ka and 7.5 ka in the Yaoxian section, Jingchuan and Huanxian sections respectively. These results are clearly inconsistent with the MIS 2/1 boundary age of 12.05 ka, and therefore we conclude that the automatic correlation of the Pleistocene/Holocene transition, as inferred from the MS record, with the MIS 2/1 boundary is incorrect. The results clearly demonstrate that the marked changes in MS along the southeast to northwest transect are time-transgressive among the different sites, with the timing of significant paleosol development as indicated by the MS record being delayed by 3-4 ka in the northwest compared to the southeast. Our results suggest that this asynchronous paleosol development during the last deglacial was caused by the delayed arrival of the summer monsoon in the northwest CLP compared to the southeast.

  7. Magnetic Media Lab

    Data.gov (United States)

    Federal Laboratory Consortium — This lab specializes in tape certification and performance characterization of high density digital tape and isprepared to support the certification of standard size...

  8. The Melbourne East Monash General Practice Database (MAGNET: Using data from computerised medical records to create a platform for primary care and health services research

    Directory of Open Access Journals (Sweden)

    Danielle Mazza

    2016-07-01

    Full Text Available The Melbourne East MonAsh GeNeral PracticE DaTabase (MAGNET research platform was launched in 2013 to provide a unique data source for primary care and health services research in Australia.  MAGNET contains information from the computerised records of 50 participating general practices and includes data from the computerised medical records of more than 1,100,000 patients.  The data extracted is patient-level episodic information and includes a variety of fields related to patient demographics and historical clinical information, along with the characteristics of the participating general practices.  While there are limitations to the data that is currently available, the MAGNET research platform continues to investigate other avenues for improving the breadth and quality of data, with the aim of providing a more comprehensive picture of primary care in Australia

  9. The Melbourne East Monash General Practice Database (MAGNET): Using data from computerised medical records to create a platform for primary care and health services research.

    Science.gov (United States)

    Mazza, Danielle; Pearce, Christopher; Turner, Lyle Robert; De Leon-Santiago, Maria; McLeod, Adam; Ferriggi, Jason; Shearer, Marianne

    2016-07-04

    The Melbourne East MonAsh GeNeral PracticE DaTabase (MAGNET) research platform was launched in 2013 to provide a unique data source for primary care and health services research in Australia.  MAGNET contains information from the computerised records of 50 participating general practices and includes data from the computerised medical records of more than 1,100,000 patients.  The data extracted is patient-level episodic information and includes a variety of fields related to patient demographics and historical clinical information, along with the characteristics of the participating general practices.  While there are limitations to the data that is currently available, the MAGNET research platform continues to investigate other avenues for improving the breadth and quality of data, with the aim of providing a more comprehensive picture of primary care in Australia.

  10. Detailed Jaramillo field reversals recorded in lake sediments from Armenia - Lower mantle influence on the magnetic field revisited

    Science.gov (United States)

    Kirscher, U.; Winklhofer, M.; Hackl, M.; Bachtadse, V.

    2018-02-01

    While it is well established that the Earth's magnetic field is generated by a self sustaining dynamo that reversed its polarity at irregular intervals in the geological past, the very mechanisms causing field reversals remain obscure. Paleomagnetic reconstructions of polarity transitions have been essential for physically constraining the underlying mechanisms in terms of time scale, but thus far remain ambiguous with regard to the transitional field geometry. Here we present new paleomagnetic records from a rapidly deposited lacustrine sediment sequence with extraordinarily stable paleomagnetic signals, which has captured in unprecedented detail the bottom (reverse to normal: R-N) and top (normal to reverse: N-R) transitions of the Jaramillo subchron (at 1.072 Ma and at 0.988 Ma). The obtained virtual geomagnetic pole (VGP) path indicates an oscillatory transitional field behavior with four abrupt transequatorial precursory jumps across the Pacific. The distribution of VGP positions indicates regions of preferred occurrence. Our results are in agreement with previously proposed bands of transitional VGP occurrence over the Americas and Australia/northwest Pacific. Additionally, our VGP positions seem to avoid large low shear velocity provinces (LLSVPs) above the core mantle boundary (CMB). Thus, our data supports the idea that the transitional field geometry is controlled by heat flux heterogeneities at the CMB linked to LLSVPs.

  11. Secondary Use of Recorded or Self-expressed Personal Data: Consumer Health Informatics and Education in the Era of Social Media and Health Apps.

    Science.gov (United States)

    Staccini, P; Fernandez-Luque, L

    2017-08-01

    Objective: To summarize the state of the art during the year 2016 in the areas related to consumer health informatics and education with a special emphasis in secondary use of patient data. Methods: We conducted a systematic review of articles published in 2016, using PubMed with a predefined set of queries. We identified over 320 potential articles for review. Papers were considered according to their relevance for the topic of the section. Using consensus, we selected the 15 most representative papers, which were submitted to external reviewers for full review and scoring. Based on the scoring and quality criteria, five papers were finally selected as best papers Results: The five best papers can be grouped in two major areas: 1) methods and tools to identify and collect formal requirements for secondary use of data, and 2) innovative topics highlighting the interest of carrying on "secondary" studies on patient data, more specifically on the data self-expressed by patients through social media tools. Regarding the formal requirements about informed consent, the selected papers report a comparison of legal aspects in European countries to find a common and unified grammar around the concept of "data donation". Regarding innovative approaches to value patient data, the selected papers report machine learning algorithms to extract knowledge from patient experience and satisfaction with health care delivery, drug and medication use, treatment compliance and barriers during cancer disease, or acceptation of public health actions such as vaccination. Conclusions: Secondary use of patient data (apart from personal health care record data) can be expressed according to many ways. Requirements to allow this secondary use have to be harmonized between countries, and social media platforms can be efficiently used to explore and create knowledge on patient experience with health problems or activities. Machine learning algorithms can explore those massive amounts of data to

  12. Novel aluminum near field transducer and highly integrated micro-nano-optics design for heat-assisted ultra-high-density magnetic recording

    International Nuclear Information System (INIS)

    Miao, Lingyun; Hsiang, Thomas Y; Stoddart, Paul R

    2014-01-01

    Heat-assisted magnetic recording (HAMR) has attracted increasing attention as one of the most promising future techniques for ultra-high-density magnetic recording beyond the current limit of 1 Tb in −2 . Localized surface plasmon resonance plays an important role in HAMR by providing a highly focused optical spot for heating the recording medium within a small volume. In this work, we report an aluminum near-field transducer (NFT) based on a novel bow-tie design. At an operating wavelength of 450 nm, the proposed transducer can generate a 35 nm spot size inside the magnetic recording medium, corresponding to a recording density of up to 2 Tb in −2 . A highly integrated micro-nano-optics design is also proposed to ensure process compatibility and corrosion-resistance of the aluminum NFT. Our work has demonstrated the feasibility of using aluminum as a plasmonic material for HAMR, with advantages of reduced cost and improved efficiency compared to traditional noble metals. (paper)

  13. Onset of industrial pollution recorded in Mumbai mudflat sediments, using integrated magnetic, Chemical, sup(210) Pb dating, and microscopic methods

    Digital Repository Service at National Institute of Oceanography (India)

    Blaha, U.; Basavaiah, N.; Deenadayalan, K.; Borole, D.V.; Mohite, R.D.

    , and S-ratio) reveals a significant contribution of ferri(o)magnetic phases in the upper zone. Based on the magnetic classification sampling intervals for cost-intensive PAH and metal analyses were determined. Steadily increasing contents of PAH...

  14. 76 FR 61679 - Privacy Act of 1974; Systems of Records

    Science.gov (United States)

    2011-10-05

    ... destruction of magnetic media. * * * * * GNSA 27 System name: Information Assurance Scholarship Program...). Categories of records in the system: Individual information to include: Title, full name, Social Security... information necessary to establish the identity of the individual, including name, address, and taxpayer...

  15. 76 FR 58857 - Privacy Act of 1974: System of Records

    Science.gov (United States)

    2011-09-22

    ...] Attachment type text. [cir] Binary image. [cir] Capture date. [cir] Description text. [cir] Format type text..., adjudicative or administrative body, when it is necessary to the litigation and one of the following is a party... electronically. The records are stored on magnetic disc, tape, digital media, and CD-ROM. RETRIEVABILITY: Much of...

  16. 77 FR 4371 - Records Schedules; Availability and Request for Comments

    Science.gov (United States)

    2012-01-27

    ... year Federal agencies create billions of records on paper, film, magnetic tape, and other media. To... distribute copies of press releases, speeches, and policy statements to foreign audiences. 14. Office of... Congress. 17. U.S. Commission on International Religious Freedom, Agency-wide (N1-220-12-1, 4 items, 2...

  17. Characterization of natural porous media by NMR and MRI techniques. High and low magnetic field studies for estimation of hydraulic properties

    Energy Technology Data Exchange (ETDEWEB)

    Stingaciu, Laura-Roxana

    2010-07-01

    The aim of this thesis is to apply different NMR techniques for: i) understanding the relaxometric properties of unsaturated natural porous media and ii) for a reliable quantification of water content and its spatial and temporal change in model porous media and soil cores. For that purpose, porous media with increasing complexity and heterogeneity were used (coarse and fine sand and different mixture of sand/clay) to determine the relaxation parameters in order to adapt optimal sequence and parameters for water imaging. Conventional imaging is mostly performed with superconducting high field scanners but low field scanners promise longer relaxation times and therefore smaller loss of signal from water in small and partially filled pores. By this reason high and low field NMR experiments were conducted on these porous media to characterize the dependence on the magnetic field strength. Correlations of the NMR experiments with classical soil physics method like mercury intrusion porosimetry; water retention curves (pF) and multi-step-outflow (MSO) were performed for the characterization of the hydraulic properties of the materials. Due to the extensive research the experiments have been structured in three major parts as follows. In the first part a comparison study between relaxation experiments in high and low magnetic field was performed in order to observe the influence of the magnetic field on the relaxation properties. Due to these results, in the second part of the study only low field relaxation experiments were used in the attempt of correlations with classical soil physics methods (mercury intrusion porosimetry and water retention curves) for characterizing the hydraulic behavior of the samples. Further, the aim was to combine also MRI experiments (2D and 3D NMR) with classical soil physics methods (multi-step-outflow, MSO) for the same purpose of investigating the hydraulic properties. Because low field MRI systems are still under developing for the

  18. Characterization of natural porous media by NMR and MRI techniques. High and low magnetic field studies for estimation of hydraulic properties

    International Nuclear Information System (INIS)

    Stingaciu, Laura-Roxana

    2010-01-01

    The aim of this thesis is to apply different NMR techniques for: i) understanding the relaxometric properties of unsaturated natural porous media and ii) for a reliable quantification of water content and its spatial and temporal change in model porous media and soil cores. For that purpose, porous media with increasing complexity and heterogeneity were used (coarse and fine sand and different mixture of sand/clay) to determine the relaxation parameters in order to adapt optimal sequence and parameters for water imaging. Conventional imaging is mostly performed with superconducting high field scanners but low field scanners promise longer relaxation times and therefore smaller loss of signal from water in small and partially filled pores. By this reason high and low field NMR experiments were conducted on these porous media to characterize the dependence on the magnetic field strength. Correlations of the NMR experiments with classical soil physics method like mercury intrusion porosimetry; water retention curves (pF) and multi-step-outflow (MSO) were performed for the characterization of the hydraulic properties of the materials. Due to the extensive research the experiments have been structured in three major parts as follows. In the first part a comparison study between relaxation experiments in high and low magnetic field was performed in order to observe the influence of the magnetic field on the relaxation properties. Due to these results, in the second part of the study only low field relaxation experiments were used in the attempt of correlations with classical soil physics methods (mercury intrusion porosimetry and water retention curves) for characterizing the hydraulic behavior of the samples. Further, the aim was to combine also MRI experiments (2D and 3D NMR) with classical soil physics methods (multi-step-outflow, MSO) for the same purpose of investigating the hydraulic properties. Because low field MRI systems are still under developing for the

  19. Finite element and network electrical simulation of rotating magnetofluid flow in nonlinear porous media with inclined magnetic field and hall currents

    Directory of Open Access Journals (Sweden)

    Bég Anwar O.

    2014-01-01

    Full Text Available A mathematical model is presented for viscous hydromagnetic flow through a hybrid non-Darcy porous media rotating generator. The system is simulated as steady, incompressible flow through a nonlinear porous regime intercalated between parallel plates of the generator in a rotating frame of reference in the presence of a strong, inclined magnetic field A pressure gradient term is included which is a function of the longitudinal coordinate. The general equations for rotating viscous magnetohydrodynamic flow are presented and neglecting convective acceleration effects, the two-dimensional viscous flow equations are derived incorporating current density components, porous media drag effects, Lorentz drag force components and Hall current effects. Using an appropriate group of dimensionless variables, the momentum equations for primary and secondary flow are rendered nondimensional and shown to be controlled by six physical parameters-Hartmann number (Ha, Hall current parameter (Nh, Darcy number (Da, Forchheimer number (Fs, Ekman number (Ek and dimensionless pressure gradient parameter (Np, in addition to one geometric parameter-the orientation of the applied magnetic field (θ . Several special cases are extracted from the general model, including the non-porous case studied earlier by Ghosh and Pop (2006. A numerical solution is presented to the nonlinear coupled ordinary differential equations using both the Network Simulation Method and Finite Element Method, achieving excellent agreement. Additionally very good agreement is also obtained with the earlier analytical solutions of Ghosh and Pop (2006. for selected Ha, Ek and Nh values. We examine in detail the effects of magnetic field, rotation, Hall current, bulk porous matrix drag, second order porous impedance, pressure gradient and magnetic field inclination on primary and secondary velocity distributions and also frictional shear stresses at the plates. Primary velocity is seen to decrease

  20. Perpendicular recording: the promise and the problems

    International Nuclear Information System (INIS)

    Wood, Roger; Sonobe, Yoshiaki; Jin Zhen; Wilson, Bruce

    2001-01-01

    Perpendicular recording has long been advocated as a means of achieving the highest areal densities. In particular, in the context of the 'superparamagnetic limit', perpendicular recording with a soft underlayer promises several key advantages. These advantages include a higher coercivity, thicker media that should permit smaller diameter grains and higher signal-to-noise ratio. Also, the sharper edge-writing will facilitate recording at very high track densities (lower bit aspect ratio). Recent demonstrations of the technology have shown densities comparable with the highest densities reported for longitudinal recording. This paper further examines the promise that perpendicular recording will deliver an increase in areal density two to eight times higher than that achievable with longitudinal recording. There are a number of outstanding issues but the key challenge is to create a low-noise medium with a coercivity that is high and is much larger than the remanent magnetization

  1. MAGNET

    CERN Multimedia

    by B. Curé

    2011-01-01

    The magnet operation was very satisfactory till the technical stop at the end of the year 2010. The field was ramped down on 5th December 2010, following the successful regeneration test of the turbine filters at full field on 3rd December 2010. This will limit in the future the quantity of magnet cycles, as it is no longer necessary to ramp down the magnet for this type of intervention. This is made possible by the use of the spare liquid Helium volume to cool the magnet while turbines 1 and 2 are stopped, leaving only the third turbine in operation. This obviously requires full availability of the operators to supervise the operation, as it is not automated. The cryogenics was stopped on 6th December 2010 and the magnet was left without cooling until 18th January 2011, when the cryoplant operation resumed. The magnet temperature reached 93 K. The maintenance of the vacuum pumping was done immediately after the magnet stop, when the magnet was still at very low temperature. Only the vacuum pumping of the ma...

  2. Environmental magnetic and petroleum hydrocarbons records in sediment cores from the north east coast of Tamilnadu, Bay of Bengal, India.

    Science.gov (United States)

    Venkatachalapathy, R; Veerasingam, S; Basavaiah, N; Ramkumar, T; Deenadayalan, K

    2011-04-01

    In this study, mineral magnetic properties and petroleum hydrocarbons were statistically analysed in four sediment cores (C1, A1, T1 and K1) from the north east coast of Tamilnadu, India to examine the feasibility of PHC concentrations assessment using magnetic susceptibility. The C1 and A1 cores reveal a clear horizon of increase in PHC above 35 and 50 cm respectively suggesting the excess anthropogenic loading occurred in the recent past. Magnetic properties which were enhanced in the upper part of the sediment cores were the result of ferrimagnetic minerals from anthropogenic sources. Factor analysis confirmed that the input of magnetic minerals and petroleum hydrocarbons in Chennai coastal sediments are derived from the same sources. The present study shows that instead of expensive and destructive PHC chemical methods, magnetic susceptibility is found to be a suitable, cheap and rapid method for detailed study of petroleum hydrocarbon contamination in marine sediments. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Multiple scattering of electromagnetic waves in disordered magnetic media localization parameter, energy transport velocity and diffusion constant

    CERN Document Server

    Pinheiro, F A; Martínez, A S

    2001-01-01

    We review some of our recent results concerning the single and multiple electromagnetic scattering by magnetic spherical particles. For a single electromagnetic scattering we show that the magnetic contribution alters, when compared to nonmagnetic scattering, the behavior of the cross sections and mean cosine of the scattering angle (cos omega). For ferromagnetic particles, resonances may occur even in the small-particle limit when the particle radius is much smaller than the wavelength. The resonances increase the cross sections while (cos omega) is diminished , and even may become negative. Several quantities such the Ioffe-Regel parameter for localization are calculated for the multiple scattering regime. We show that magnetic scattering favors the observation of localization of electromagnetic waves in three dimensions. Further, this is also verified for dynamical experiments, where we show that the diffusion constant can be very small. Since the magnetic permeability of the scatterers can vary significan...

  4. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    Operation of the magnet has gone quite smoothly during the first half of this year. The magnet has been at 4.5K for the full period since January. There was an unplanned short stop due to the CERN-wide power outage on May 28th, which caused a slow dump of the magnet. Since this occurred just before a planned technical stop of the LHC, during which access in the experimental cavern was authorized, it was decided to leave the magnet OFF until 2nd June, when magnet was ramped up again to 3.8T. The magnet system experienced a fault also resulting in a slow dump on April 14th. This was triggered by a thermostat on a filter choke in the 20kA DC power converter. The threshold of this thermostat is 65°C. However, no variation in the water-cooling flow rate or temperature was observed. Vibration may have been the root cause of the fault. All the thermostats have been checked, together with the cables, connectors and the read out card. The tightening of the inductance fixations has also been checked. More tem...

  5. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet was energised at the beginning of March 2012 at a low current to check all the MSS safety chains. Then the magnet was ramped up to 3.8 T on 6 March 2012. Unfortunately two days later an unintentional switch OFF of the power converter caused a slow dump. This was due to a misunderstanding of the CCC (CERN Control Centre) concerning the procedure to apply for the CMS converter control according to the beam-mode status at that time. Following this event, the third one since 2009, a discussion was initiated to define possible improvement, not only on software and procedures in the CCC, but also to evaluate the possibility to upgrade the CMS hardware to prevent such discharge from occurring because of incorrect procedure implementations. The magnet operation itself was smooth, and no power cuts took place. As a result, the number of magnetic cycles was reduced to the minimum, with only two full magnetic cycles from 0 T to 3.8 T. Nevertheless the magnet suffered four stops of the cryogeni...

  6. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  7. Electron Pitch Angle Variations Recorded at the High Magnetic Latitude Boundary Layer by the NUADU Instrument on the TC-2 Spacecraft

    Science.gov (United States)

    Lu, L.; McKenna-Lawlor, S.; Barabash, S.; Liu, Z.; Balaz, J.; Brinkfeldt, K.; Strhansky, I.; Shen, C.; Shi, J.; Cao, J.; Pu, Z.; Fu, S.; Gunell, H.; Kudela, K.; Roelof, E. C.; Brandt, P. C.; Dandouras, I.; Zhang, T.; Carr, C.; Fazakerley, A.

    2005-12-01

    During the first on orbit commission, with the deflection high voltage zero, the NUADU (NeUtral Atom Detector Unit) instrument aboard TC-2, with its high temporal-spatial resolution recorded 4d solid angle images of energetic particles spiraling around the geomagnetic field lines with different configuration at high northern magnetic latitude L>10. The ambient magnetic field and particles in different energy spectrum were simultaneously measured by the magnetometer experiment (FGM), the plasma electron and current experiment (PEACE), the low energy ion detector (LEID), and the high energy electron detector (HEED). The up-flowing electron beams made the pitch angle distribution (PAD) ring like configuration, and even concentrated toward the field lines to form a dumbbell-type PAD. In integration of the variations of ambient magnetic field and particles in different energy spectrums, a temporal string magnetic bottle model was proposed which might be formed by the disturbance of the magnetic pulse. Changes in the particle pitch angle diffusion may be associated with electron acceleration along the geomagnetic field lines.

  8. Electron pitch angle variations recorded at the high magnetic latitude boundary layer by the NUADU instrument on the TC-2 spacecraft

    Directory of Open Access Journals (Sweden)

    L. Lu

    2005-11-01

    Full Text Available The NUADU (NeUtral Atom Detector Unit experiment aboard TC-2 recorded, with high temporal and spatial resolution, 4π solid angle images of electrons (~50-125 keV spiraling around geomagnetic field lines at high northern magnetic latitudes (L>10, during its in-orbit commissioning phase (September 2004. The ambient magnetic field, as well as electrons in other energy ranges, were simultaneously measured by the TC-2 magnetometer (FGM, the plasma electron and current experiment (PEACE, the low energy ion detector (LEID and the high energy electron detector (HEED. The NUADU data showed that up-flowing electron beams could form "ring-like" and "dumbbell-type" pitch angle distributions (PADs in the region sampled. Changes in these pitch angle distributions due to transient magnetic variations are suggested to have been associated with electron acceleration along the geomagnetic field lines. A nested magnetic bottle configuration that formed due to the propagation towards the Earth of a magnetic pulse, is proposed to have been associated with this process.

  9. The design and optimization of disk structures for MAMMOS/MSR magneto-optic recording

    International Nuclear Information System (INIS)

    Hendren, W R; Atkinson, R; Pollard, R J; Salter, I W; Wright, C D; Clegg, W W; Jenkins, D F L

    2005-01-01

    Existing quadrilayer and trilayer techniques for optimizing the magneto-optical effects from magnetic materials have been applied to new generation recording media to investigate the possibility of maximizing the signal-to-noise readout performance. Various methods are reviewed and the designs they produce are compared with each other and with the working media found in the literature. In order to address a number of inadequacies, a new numerical approach to the optimization of a quadrilayer structure is used to find further solutions that are considered more suitable for the practical recording media. The effects on design and performance of medium of incidence, type of storage layer and wavelength are all considered

  10. The design and optimization of disk structures for MAMMOS/MSR magneto-optic recording

    Energy Technology Data Exchange (ETDEWEB)

    Hendren, W R [School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Atkinson, R [School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Pollard, R J [School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Salter, I W [School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Wright, C D [School of Engineering and Computer Science, University of Exeter, Exeter EX4 4QF (United Kingdom); Clegg, W W [Centre for Research in Information Storage Technology, University of Plymouth, Plymouth PL4 8AA (United Kingdom); Jenkins, D F L [Centre for Research in Information Storage Technology, University of Plymouth, Plymouth PL4 8AA (United Kingdom)

    2005-07-21

    Existing quadrilayer and trilayer techniques for optimizing the magneto-optical effects from magnetic materials have been applied to new generation recording media to investigate the possibility of maximizing the signal-to-noise readout performance. Various methods are reviewed and the designs they produce are compared with each other and with the working media found in the literature. In order to address a number of inadequacies, a new numerical approach to the optimization of a quadrilayer structure is used to find further solutions that are considered more suitable for the practical recording media. The effects on design and performance of medium of incidence, type of storage layer and wavelength are all considered.

  11. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet and its sub-systems were stopped at the beginning of the winter shutdown on 8th December 2011. The magnet was left without cooling during the cryogenics maintenance until 17th January 2012, when the cryoplant operation resumed. The magnet temperature reached 93 K. The vacuum pumping was maintained during this period. During this shutdown, the yearly maintenance was performed on the cryogenics, the vacuum pumps, the magnet control and safety systems, and the power converter and discharge lines. Several preventive actions led to the replacement of the electrovalve command coils, and the 20A DC power supplies of the magnet control system. The filters were cleaned on the demineralised water circuits. The oil of the diffusion pumps was changed. On the cryogenics, warm nitrogen at 343 K was circulated in the cold box to regenerate the filters and the heat exchangers. The coalescing filters have been replaced at the inlet of both the turbines and the lubricant trapping unit. The active cha...

  12. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

      The magnet was operated without any problem until the end of the LHC run in February 2013, apart from a CERN-wide power glitch on 10 January 2013 that affected the CMS refrigerator, causing a ramp down to 2 T in order to reconnect the coldbox. Another CERN-wide power glitch on 15 January 2013 didn’t affect the magnet subsystems, the cryoplant or the power converter. At the end of the magnet run, the reconnection of the coldbox at 2.5 T was tested. The process will be updated, in particular the parameters of some PID valve controllers. The helium flow of the current leads was reduced but only for a few seconds. The exercise will be repeated with the revised parameters to validate the automatic reconnection process of the coldbox. During LS1, the water-cooling services will be reduced and many interventions are planned on the electrical services. Therefore, the magnet cryogenics and subsystems will be stopped for several months, and the magnet cannot be kept cold. In order to avoid unc...

  13. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet was successfully operated at the end of the year 2009 despite some technical problems on the cryogenics. The magnet was ramped up to 3.8 T at the end of November until December 16th when the shutdown started. The magnet operation met a few unexpected stops. The field was reduced to 3.5 T for about 5 hours on December 3rd due to a faulty pressure sensor on the helium compressor. The following day the CERN CCC stopped unintentionally the power converters of the LHC and the experiments, triggering a ramp down that was stopped at 2.7 T. The magnet was back at 3.8 T about 6 hours after CCC sent the CERN-wide command. Three days later, a slow dump was triggered due to a stop of the pump feeding the power converter water-cooling circuit, during an intervention on the water-cooling plant done after several disturbances on the electrical distribution network. The magnet was back at 3.8 T in the evening the same day. On December 10th a break occurred in one turbine of the cold box producing the liquid ...

  14. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The CMS magnet has been running steadily and smoothly since the summer, with no detected flaw. The magnet instrumentation is entirely operational and all the parameters are at their nominal values. Three power cuts on the electrical network affected the magnet run in the past five months, with no impact on the data-taking as the accelerator was also affected at the same time. On 22nd June, a thunderstorm caused a power glitch on the service electrical network. The primary water cooling at Point 5 was stopped. Despite a quick restart of the water cooling, the inlet temperature of the demineralised water on the busbar cooling circuit increased by 5 °C, up to 23.3 °C. It was kept below the threshold of 27 °C by switching off other cooling circuits to avoid the trigger of a slow dump of the magnet. The cold box of the cryogenics also stopped. Part of the spare liquid helium volume was used to maintain the cooling of the magnet at 4.5 K. The operators of the cryogenics quickly restarted ...

  15. Magnetic force microscopy: advanced technique for the observation of magnetic domains

    International Nuclear Information System (INIS)

    Asenjo, A.; Garcia, J. M.; Vazquez, M.

    2001-01-01

    An overview on the Magnetic Force Microscopy, MFM, as an advanced technique to observe magnetic domains and walls is displayed. Basic concepts are first introduced on the domain structure formation as well as on other techniques to observe magnetic domains. Afterwards, the MFM instrumentation is described making also an emphasis in micro magnetic consideration to interpret the images. Finally, a set of selected advanced magnetic materials with different domain structures is chosen to show the wide possibilities of this techniques to characterise the surface magnetic behaviour. The domain structure of materials as commercial magnetic recording media, thin films and multilayers, amorphous micro tubes, nanocrystalline ribbons, perovskites or magnetic nano wires is shown. (Author) 16 refs

  16. Contrast media and the brain - the basis of computed tomography and magnetic resonance imaging enhancement: a review

    International Nuclear Information System (INIS)

    Sage, M.R.; Wilson, A.J.; Scroop, R.

    2000-01-01

    The blood, cerebrospinal fluid (CSF), and extracellular fluid of the parenchyma form the fluid compartments of the brain with three interfaces between, namely the blood-brain interface (BBB), the CSF-brain interface, and the blood-CSF interface. When either water-soluble iodinated contrast media (CM) or water-soluble paramagnetic CM are injected intravenously, they are rapidly brought into contact with both the BBB and the blood-CSF interface. It is the behaviour of the water-soluble CM at these two interfaces that determines the normal and abnormal enhancement patterns demonstrated by either CT or MRI. Unlike lipophilic solutes, current iodinated and MRI contrast media all have high affinities for plasma water, low affinities for plasma proteins and, in particular, extremely low partition coefficients. Therefore they do not penetrate the normal BBB. On the other hand, radiopharmaceuticals used in positron emission tomography (PET) and single photon emission computed tomography (SPECT) to demonstrate regional cerebral blood flow are highly lipophilic and readily cross the intact BBB completely during the first pass through the cerebral vasculature. It is the inability of the current iodinated and MRI contrast media to cross the normal intact BBB that is the basis of their use in CT and MRI studies of the brain. Copyright (1999) Blackwell Science Pty Ltd

  17. Self-organisation, orientation and magnetic properties of FePt nanoparticle arrays

    International Nuclear Information System (INIS)

    Verdes, C.; Chantrell, R.W.; Satoh, A.; Harrell, J.W.; Nikles, D.

    2006-01-01

    Self-organised magnetic arrays (SOMA) of high anisotropy particles are a promising candidate for ultra-high-density recording media. In principle SOMA media have the capability of storing 1 bit per particle, leading to possible reecording densities in excess of 10 Tbit/sq in. In this paper we consider two major aspects of SOMA media, namely the self-organisation process itself and the physics of the particle orientation process

  18. Interactions between 9,10-anthraquinone and aromatic amines in homogeneous and micellar media: A laser flash photolysis and magnetic field effect study

    International Nuclear Information System (INIS)

    Chowdhury, Adity; Basu, Samita

    2006-01-01

    The interactions between 9,10-anthraquinone (AQ) and different aromatic amines, N,N-dimethylaniline and 4,4'-bis (dimethylamino) diphenylmethane (DMDPM), have been studied using absorption, steady-state fluorescence, and laser flash photolysis techniques in organic homogeneous and heterogeneous micellar media. In polar organic homogeneous medium, electron transfer (ET) occurs from amines to excited AQ. In micellar medium, similar intermolecular ET is observed. However, in latter medium, ET predominates over hydrogen abstraction from micelles by excited AQ itself. The occurrence of ET has been further supported by the application of an external magnetic field during laser flash photolysis experiments, which modulates the yield of radical ion pairs formed through ET. Another novel feature, which has also been discussed here, is the abnormal behavior of DMDPM in micellar medium pertaining to energy transfer

  19. Magnetic Polarity Stratigraphy and Rock Magnetic Data From the Continuous Cored Record of Triassic Continental Environmental Change, the Colorado Plateau Coring Project

    Science.gov (United States)

    Geissman, J. W.; McIntosh, J.; Buhedma, H. M. A.

    2017-12-01

    Despite the fact that the Triassic Period (ca. 251.9-201.3 Ma) is bound by two of Earth's largest mass extinctions, experienced giant bolide impacts and eruption of three large igneous provinces, and witnessed evolution of the main components of modern tetrapod communities, the time interval has sparse geochronologic calibration. The US NSF- and ICDP-funded coring of Phase 1 of the CPCP was completed in 2013, with the recovery of two major cores (6.35 cm diameter: 1A, 518m length and 2B, 253m; 31km apart) from the Petrified Forest National Park spanning the Chinle and Moenkopi fms. Core 1A has been fully sampled, with specimens obtained either by drilling or by extraction of core fragments and packing in ceramic boxes. Specimens are subjected to progressive thermal demagnetization or a combination of alternating field (AF) followed by thermal treatment. In several cases, specimens were extracted from each core segment to test for internal consistency. Chinle hematitic mudstones and siltstones have NRM intensities between 130 to 0.5 mA/m, with bulk susceptibilities from 2 x 10-2 to 5 x 10-5 SI units. More indurated hematitic siltstones/ medium sandstones of the Moenkopi Fm have NRM intensities and bulk susceptibilities that are far less variable (NRM: 9.0 to 1.2 mA/m, MS: 3.0 X 10-4 and 0.5 x 10-5 SI vol). Thermal demagnetization typically isolates magnetizations of N declination and shallow inclination (interpreted as normal polarity) and antipodes (reverse) (image), a polarity stratigraphy is being compiled for much of the section. Response is typically more interpretable for very hematitic Chinle mudstone sections and most Moenkopi rocks. Coarser grained, less hematitic Chinle strata rarely yield interpretable results, likely due to coarse-grained detrital magnetite, and it is likely that these intervals will not yield robust polarity information. Some core segments yield well-resolved magnetizations that are inconsistent with a Triassic field and we suspect

  20. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  1. Magnetic Properties of the Rivers Feeding the South China Sea: a Critical Step for Understanding the Paleo-Marine Records.

    Science.gov (United States)

    Kissel, C.; Liu, Z.; Wandres, C.

    2014-12-01

    In order to use the magnetic properties of marine sediments as a tracer for past changes in the precipitation rate on land and in oceanic water masses transport and exchanges in the South China Sea, we identify and characterize the different sources of the detrital fraction among which the magnetic particles. This work is presently conducted in the framework of the Franco-Chinese LIA-MONOCL Thanks to the Westpac project, we had access to sediments collected in the deltas of the main rivers feeding the South China Sea from about 25°N to the equator. This is represented on the Asian continent by the Pearl river, the Red River, the Mekong river, by Malaysia, Sumatra and Borneo regions with minor rivers but also contributing to the South China Sea, and finally by Luzon and Taiwan. The geological formations contributing to the river sediment discharges are different from one catchment basin to another as well as the present climatic conditions. The magnetic analyses consist in the analysis of low-field magnetic susceptibility, ARM acquisition and decay, IRM acquisition and decay, back-field acquisition, thermal demagnetization of 3-axes IRM, hysteresis parameters, and FORC diagrams. The obtained parameters all together allow us to define the nature of the magnetic grains and their grain size distribution when magnetite is dominant. Some degree of variability is observed at the river mouths, illustrating different geological sources at the local/regional scale. As an average, it appears that the Southern basin of the South China Sea is surrounded by regions richer in high coercivity magnetic minerals than the northern basin. This mineral is identified as hematite while magnetites (and sulfides) are more abundant in the north. These results are complementary to the clay mineral assemblages previously determined on the same samples. The first steps of a similar study conducted on marine core-tops well distributed in the South China Sea will also be illustrated.

  2. Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact

    DEFF Research Database (Denmark)

    Tomasevic, Leo; Takemi, Mitsuaki; Siebner, Hartwig Roman

    2017-01-01

    delivered monophasic and biphasic TMS to a melon as head phantom and to four healthy participants and recorded the pulse artefact at 5 kHz with a TMS-compatible EEG system. Pulse delivery was either synchronized or non-synchronized to the clock of the EEG recording system. The effects of synchronization...... were tested at 10 and 20 kHz using the head phantom. We also tested the effect of a soft sheet placed between the stimulation coil and recording electrodes in both human and melon. RESULTS & CONCLUSION: Synchronizing TMS and data acquisition markedly reduced trial-to-trial variability of the pulse...

  3. Record of the Cretaceous magnetic quiet zone: A precursor to the understanding of evolutionary history of the Bay of Bengal

    Digital Repository Service at National Institute of Oceanography (India)

    Ramana, M.V; Subrahmanyam, V; Sarma, K.V; Desa, M.; Rao, M.M.M.; Subrahmanyam, C.

    Magnetic study along a transect joining the sites of Ocean Drilling Programme (OPD) keg 116 (1 degrees S, 81 degrees 24'E) and the vicinity of Deep Sea Drilling Project (DSDP) site 218 (7 degrees N, 87 degrees 30'E) revealed the presence of a wide...

  4. 36 CFR 1235.46 - What electronic media may be used for transferring records to the National Archives of the United...

    Science.gov (United States)

    2010-07-01

    ... Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION RECORDS MANAGEMENT... contain only permanent records. Agencies must indicate at the time of transfer if a CD-ROM or DVD contains... Division (NWCS), 8601 Adelphi Road, College Park, MD 20740, phone number (301) 837-2903, or the National...

  5. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet worked very well at 3.8 T as expected, despite a technical issue that manifested twice in the cryogenics since June. All the other magnet sub-systems worked without flaw. The issue in the cryogenics was with the cold box: it could be observed that the cold box was getting progressively blocked, due to some residual humidity and air accumulating in the first thermal exchanger and in the adsorber at 65 K. This was later confirmed by the analysis during the regeneration phases. An increase in the temperature difference between the helium inlet and outlet across the heat exchanger and a pressure drop increase on the filter of the adsorber were observed. The consequence was a reduction of the helium flow, first compensated by the automatic opening of the regulation valves. But once they were fully opened, the flow and refrigeration power reduced as a consequence. In such a situation, the liquid helium level in the helium Dewar decreased, eventually causing a ramp down of the magnet current and a field...

  6. MAGNET

    CERN Multimedia

    B. Curé

    MAGNET During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bough...

  7. MAGNET

    CERN Multimedia

    Benoit Curé.

    The magnet operation restarted end of June this year. Quick routine checks of the magnet sub-systems were performed at low current before starting the ramps up to higher field. It appeared clearly that the end of the field ramp down to zero was too long to be compatible with the detector commissioning and operations plans. It was decided to perform an upgrade to keep the ramp down from 3.8T to zero within 4 hours. On July 10th, when a field of 1.5T was reached, small movements were observed in the forward region support table and it was decided to fix this problem before going to higher field. At the end of July the ramps could be resumed. On July 28th, the field was at 3.8T and the summer CRAFT exercise could start. This run in August went smoothly until a general CERN wide power cut took place on August 3rd, due to an insulation fault on the high voltage network outside point 5. It affected the magnet powering electrical circuit, as it caused the opening of the main circuit breakers, resulting in a fast du...

  8. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

    The magnet is fully stopped and at room temperature. The maintenance works and consolidation activities on the magnet sub-systems are progressing. To consolidate the cryogenic installation, two redundant helium compressors will be installed as ‘hot spares’, to avoid the risk of a magnet downtime in case of a major failure of a compressor unit during operation. The screw compressors, their motors, the mechanical couplings and the concrete blocks are already available and stored at P5. The metallic structure used to access the existing compressors in SH5 will be modified to allow the installation of the two redundant ones. The plan is to finish the installation and commissioning of the hot spare compressors before the summer 2014. In the meantime, a bypass on the high-pressure helium piping will be installed for the connection of a helium drier unit later during the Long Shutdown 1, keeping this installation out of the schedule critical path. A proposal is now being prepared for the con...

  9. Effect of carbon embedding on the tribological properties of magnetic media surface with and without a perfluoropolyether (PFPE) layer

    International Nuclear Information System (INIS)

    Samad, M Abdul; Yang, H; Bhatia, C S; Sinha, S K

    2011-01-01

    Carbon embedding (≤1 nm) in the top surface of cobalt (∼100 nm) sputtered on a silicon surface is used as a surface modification technique to evaluate the tribological properties with or without an ultra-thin layer of perfluoropolyether (PFPE) lubricant. The carbon embedding is achieved using the filtered cathodic vacuum arc technique at an ion energy of 90 eV. Transport of ions in matter simulations, time-of-flight secondary ion spectroscopy, transmission electron microscopy and x-ray photoelectron spectroscopy (XPS) are used to study the carbon embedding profiles and surface chemical composition. The XPS results show that carbon embedding using the ion energy of 90 eV results in the formation of about 58 ± 6% of tetrahedral (sp 3 ) carbon hybridization. Furthermore, the XPS results also show that the carbon embedding is effective in improving the anti-oxidation resistance of cobalt. Ball-on-disk tribological tests are conducted at a contact pressure of 0.26 GPa on the modified cobalt surface with or without the PFPE layer. It is observed that the average coefficient of friction is reduced considerably from a value of approximately 0.7 to 0.42 after the surface modification. The coefficient of friction is further reduced to ∼0.26 after the deposition of an ultra-thin layer of PFPE over the modified surface, which is lower than a friction coefficient of 0.4 from commercial media. The modified cobalt surface also shows much better wear life than the present day commercial media.

  10. Drive-based recording analyses at >800 Gfc/in2 using shingled recording

    International Nuclear Information System (INIS)

    William Cross, R.; Montemorra, Michael

    2012-01-01

    Since the introduction of perpendicular recording, conventional perpendicular scaling has enabled the hard disk drive industry to deliver products ranging from ∼130 to well over 500 Gb/in 2 in a little over 4 years. The incredible areal density growth spurt enabled by perpendicular recording is now endangered by an inability to effectively balance writeability with erasure effects at the system level. Shingled magnetic recording (SMR) offers an effective means to continue perpendicular areal density growth using conventional heads and tuned media designs. The use of specially designed edge-write head structures (also known as 'corner writers') should further increase the AD gain potential for shingled recording. In this paper, we will demonstrate the drive-based recording performance characteristics of a shingled recording system at areal densities in excess of 800 Gb/in 2 using a conventional head. Using a production drive base, developmental heads/media and a number of sophisticated analytical routines, we have studied the recording performance of a shingled magnetic recording subsystem. Our observations confirm excellent writeability in excess of 400 ktpi and a perpendicular system with acceptable noise balance, especially at extreme ID and OD skews where the benefits of SMR are quite pronounced. We believe that this demonstration illustrates that SMR is not only capable of productization, but is likely the path of least resistance toward production drive areal density closer to 1 Tb/in 2 and beyond. - Research highlights: → Drive-based recording demonstrations at 805 Gf/in 2 has been demonstrated using both 95 and 65 mm drive platforms at roughly 430 ktpi and 1.87 Mfci. → Limiting factors for shingled recording include side reading, which is dominated by the reader crosstrack skirt profile, MT10 being a representative metric. → Media jitter and associated DC media SNR further limit areal density, dominated by crosstrack transition curvature, downtrack

  11. MAGNET

    CERN Multimedia

    Benoit Curé

    The magnet subsystems resumed operation early this spring. The vacuum pumping was restarted mid March, and the cryogenic power plant was restarted on March 30th. Three and a half weeks later, the magnet was at 4.5 K. The vacuum pumping system is performing well. One of the newly installed vacuum gauges had to be replaced at the end of the cool-down phase, as the values indicated were not coherent with the other pressure measurements. The correction had to be implemented quickly to be sure no helium leak could be at the origin of this anomaly. The pressure measurements have been stable and coherent since the change. The cryogenics worked well, and the cool-down went quite smoothly, without any particular difficulty. The automated start of the turbines had to be fine-tuned to get a smooth transition, as it was observed that the cooling power delivered by the turbines was slightly higher than needed, causing the cold box to stop automatically. This had no consequence as the cold box safety system acts to keep ...

  12. MAGNET

    CERN Multimedia

    B. Curé

    During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bought. Th...

  13. Greigite (Fe3S4) as an indicator of drought - The 1912-1994 sediment magnetic record from White Rock Lake, Dallas, Texas, USA

    Science.gov (United States)

    Reynolds, R.L.; Rosenbaum, J.G.; Van Metre, P.; Tuttle, M.; Callender, E.; Goldin, A.

    1999-01-01

    Combined magnetic and geochemical studies were conducted on sediments from White Rock Lake, a reservoir in suburban Dallas (USA), to investigate how land use has affected sediment and water quality since the reservoir was filled in 1912. The chronology of a 167-cm-long core is constrained by the recognition of the pre-reservoir surface and by 137Cs results. In the reservoir sediments, magnetic susceptibility (MS) and isothermal remanent magnetization (IRM) are largely carried by detrital titanomagnetite that originally formed in igneous rocks. Titanomagnetite and associated hematite are the dominant iron oxides in a sample from the surficial deposit in the watershed but are absent in the underlying Austin Chalk. Therefore, these minerals were transported by wind into the watershed. After about 1960, systematic decreases in Ti, Fe, and Al suggest diminished input of detrital Fe-Ti oxides from the surficial deposits. MS and IRM remain constant over this interval, however, implying compensation by an increase in strongly magnetic material derived from human activity. Anthropogenic magnetite in rust and ferrite spherules (from fly ash?) are more common in sediment deposited after about 1970 than before and may account for the constant magnetization despite the implied decrease in detrital Fe-Ti oxides. An unexpected finding is the presence of authigenic greigite (Fe3S4), the abundance of which is at least partly controlled by climate. Greigite is common in sediments that predate about 1975, with zones of concentration indicated by relatively high IRM/MS. High greigite contents in sediment deposited during the early to mid-1950s and during the mid-1930s correspond to several-year periods of below-average precipitation and drought from historical records. Relatively long water-residence times in the reservoir during these periods may have led to elevated levels of sulfate available for bacterial sulfate reduction. The sulfate was probably derived via the oxidation of

  14. Review of past, present, and future of recording technology

    Science.gov (United States)

    Al-Jibouri, Abdul-Rahman

    2003-03-01

    The revolution of information storage and recording has been advanced significantly over the past two decades. Since the development of computers in early 1950s by IBM, the data (information) was stored on magnetic disc by inducing magnetic flux to define the pit direction. The first disc was developed by IBM with diameter of 25inch to store around 10 kByte. After four decades, the disc drive has become more advanced by reducing the drive size, increasing ariel density and cost reduction. The introduction of new computer operating systems and the Internet resulted in the need to develop high ariel density in the 1990s. Therefore, the disc drive manufacturers were pushed harder to develop new technologies at low cost to survive the competitive market. The disc drives, which are based on media (where the data/information is stored) and the head (which will write and read data/information). The head and disc are separated and with the current technology the spacing between the disc and head is about 40nm. A new technology based on magnetic recording was developed to serve the audio market. This technology is called magnetic type, it is similar to the disc drive, but the media is based on tape rather than rigid disc. Another difference being the head and media are in direct contact. Magnetic tape was developed for audio application and a few years later this technology was extended to allow and accept another technology, called video. This allows consumers to record and view movies in their home. The magnetic tape also used the computer industries for back up data. Magnetic tape is still used in computers and has advanced further over the past decade, companies like Quantum Corp has developed digital linear tape.

  15. SOCIAL MEDIA

    Science.gov (United States)

    RESPONSIBILITY CENTCOM COALITION MEDIA SOCIAL MEDIA NEWS ARTICLES PRESS RELEASES IMAGERY VIDEOS TRANSCRIPTS VISITORS AND PERSONNEL FAMILY CENTER FAMILY READINESS CENTCOM WEBMAIL SOCIAL MEDIA SECURITY ACCOUNTABILITY HomeMEDIASOCIAL MEDIA Social Media CENTCOM'S ENGLISH SOCIAL MEDIA ACCOUNTS There are many U.S. military commands

  16. Magnetic and Geochemical Records of Glacial Terminations, Weathering and Carbon Burial in the Southeastern South China Sea for the Last 800 kyr

    Science.gov (United States)

    Kandasamy, S.; Kao, S.; Hsu, S.; Lee, T.; Velasco, V. M.; Soon, W.; Chen, M.

    2013-12-01

    Rebuilding of past climate and oceanographic records from monsoon dominated Asia is of vital importance for understanding the causes and mechanisms of global and regional climate changes at orbital-millennial timescales. South China Sea (SCS) provides the best marine platform to investigate a number of paleoclimate and paleoceanographic problems on different timescales mainly because of high sedimentation rates, good preservation of microfossils and the location of SCS as a connector between the Western Pacific Warm Pool and the SE Asian monsoon. Here we investigate magnetic, geochemical and isotopic records from a piston core MD97-2142 rose from the southeastern SCS to understand the past glacial terminations, chemical weathering and carbon burial on orbital to millennial timescales for the last 800 kyr. Terrigenous content and Al/Ti ratio reveal higher terrigenous input during glacial periods and vice versa during interglacials. Proxies of chemical weathering reveal larger fluctuations between 150 and 500 kyr than that of the last 150 kyr. Records of C/N ratio and carbon isotope of total organic carbon (δ13CTOC) mimic each other with higher marine productivity during marine isotope stages (MIS) 8, 10 and 12. Enrichment factors of Mn and Mo (EF Mn and EF Mo) show roughly an opposite pattern with 1 in most odd MIS, whereas <~1 EF Mn was evident in even MIS, suggesting that the former condition was likely attributed to bottom water ventilation associated with high sea levels during interglacials. We found through two endmember mixing model of δ13CTOC that lower burial of terrigenous fraction of TOC (OCTERR) during glacial intervals (MIS 6, 8, 10 and 12), but vice versa during interglacial (MIS 7, 9 and 11) periods. Our bulk magnetic susceptibility (MS) time series documents the last seven glacial terminations (T1-T7) with distinctive behaviors of T4 and T6. Wavelet analysis of MS record exhibits statistically significant periodicity at 239 kyr, 142 kyr, 85 kyr, 45

  17. Layer-resolved readout of magnetic signals using ferromagnetic resonance effect

    International Nuclear Information System (INIS)

    Yang, T.; Suto, H.; Nagasawa, T.; Kudo, K.; Mizushima, K.; Sato, R.

    2013-01-01

    We introduce a method to read the data stored in a three-dimensional (3D) magnetic recording medium comprising plural storage layers. The readout is realized by selecting the storage layer with the ferromagnetic resonance frequency, and detecting the magnetization orientation with the ferromagnetic resonance absorption. This concept is experimentally confirmed with magnetic media comprising NiFe and CoFe layers. The feasibility of applying this method to a realistic 3D magnetic recording medium is discussed by calculating the absorption spectra of several storage layers with different perpendicular magnetic anisotropy constants. - Highlights: ► A method is introduced to read data in the 3-dimensional magnetic recording medium. ► The storage layer to read is selected according to its particular FMR frequency. ► The magnetization of the selected storage layer is detected with the FMR absorption

  18. (0 0 1) textured CoPt-Ag nanocomposite films for high-density perpendicular magnetic recording

    International Nuclear Information System (INIS)

    Xue, S.X.; Wang, H.; Wang, H.B.; Yang, F.J.; Wang, J.A.; Cao, X.; Gao, Y.; Huang, Z.B.; Li, Z.Y.; Li, Q.; Wong, S.P.

    2006-01-01

    CoPt/Ag nanocomposite films were prepared by magnetron sputtering. The dependence of texture and magnetic properties on film thickness, Ag atomic fraction and annealing conditions is investigated. Films with a thickness about 20 nm are easy to form with (0 0 1) orientation. The existence of the Ag in the film plays a dominant role in inducing the (0 0 1) texture of the film and suppressing the growth of the CoPt grains during annealing. The Co 35 Pt 38 Ag 27 film after annealing at 600 deg. C exhibits a large perpendicular coercivity of 5.6 kOe and a squareness of 0.90 with a small average grains size of 12.5 nm

  19. Magnetic

    Science.gov (United States)

    Aboud, Essam; El-Masry, Nabil; Qaddah, Atef; Alqahtani, Faisal; Moufti, Mohammed R. H.

    2015-06-01

    The Rahat volcanic field represents one of the widely distributed Cenozoic volcanic fields across the western regions of the Arabian Peninsula. Its human significance stems from the fact that its northern fringes, where the historical eruption of 1256 A.D. took place, are very close to the holy city of Al-Madinah Al-Monawarah. In the present work, we analyzed aeromagnetic data from the northern part of Rahat volcanic field as well as carried out a ground gravity survey. A joint interpretation and inversion of gravity and magnetic data were used to estimate the thickness of the lava flows, delineate the subsurface structures of the study area, and estimate the depth to basement using various geophysical methods, such as Tilt Derivative, Euler Deconvolution and 2D modeling inversion. Results indicated that the thickness of the lava flows in the study area ranges between 100 m (above Sea Level) at the eastern and western boundaries of Rahat Volcanic field and getting deeper at the middle as 300-500 m. It also showed that, major structural trend is in the NW direction (Red Sea trend) with some minor trends in EW direction.

  20. MAGNET

    CERN Multimedia

    Benoit Curé

    The cooling down to the nominal temperature of 4.5 K was achieved at the beginning of August, in conjunction with the completion of the installation work of the connection between the power lines and the coil current leads. The temperature gradient on the first exchanger of the cold box is now kept within the nominal range. A leak of lubricant on a gasket of the helium compressor station installed at the surface was observed and several corrective actions were necessary to bring the situation back to normal. The compressor had to be refilled with lubricant and a regeneration of the filters and adsorbers was necessary. The coil cool down was resumed successfully, and the cryogenics is running since then with all parameters being nominal. Preliminary tests of the 20kA coil power supply were done earlier at full current through the discharge lines into the dump resistors, and with the powering busbars from USC5 to UXC5 without the magnet connected. On Monday evening August 25th, at 8pm, the final commissionin...

  1. MAGNET

    CERN Document Server

    B. Curé

    The first phase of the commissioning ended in August by a triggered fast dump at 3T. All parameters were nominal, and the temperature recovery down to 4.5K was carried out in two days by the cryogenics. In September, series of ramps were achieved up to 3 and finally 3.8T, while checking thoroughly the detectors in the forward region, measuring any movement of and around the HF. After the incident of the LHC accelerator on September 19th, corrective actions could be undertaken in the forward region. When all these displacements were fully characterized and repetitive, with no sign of increments in displacement at each field ramp, it was possible to start the CRAFT, Cosmic Run at Four Tesla (which was in fact at 3.8T). The magnet was ramped up to 18.16kA and the 3 week run went smoothly, with only 4 interruptions: due to the VIP visits on 21st October during the LHC inauguration day; a water leak on the cooling demineralized water circuit, about 1 l/min, that triggered a stop of the cooling pumps, and resulte...

  2. MAGNET

    CERN Multimedia

    Benoit Curé

    2013-01-01

    Maintenance work and consolidation activities on the magnet cryogenics and its power distribution are progressing according to the schedules. The manufacturing of the two new helium compressor frame units has started. The frame units support the valves, all the sensors and the compressors with their motors. This activity is subcontracted. The final installation and the commissioning at CERN are scheduled for March–April 2014. The overhauls of existing cryogenics equipment (compressors, motors) are in progress. The reassembly of the components shall start in early 2014. The helium drier, to be installed on the high-pressure helium piping, has been ordered and will be delivered in the first trimester of 2014. The power distribution for the helium compressors in SH5 on the 3.3kV network is progressing. The 3.3kV switches, between each compressor and its hot spare compressor, are being installed, together with the power cables for the new compressors. The 3.3kV electrical switchboards in SE5 will ...

  3. Children having magnetic resonance imaging: A preparatory storybook and audio/visual media are preferable to anesthesia or deep sedation.

    Science.gov (United States)

    Törnqvist, Erna; Månsson, Åsa; Hallström, Inger

    2015-09-01

    As a magnetic resonance imaging (MRI) examination lasts about 45 minutes and as the technique is sensitive to motion, children are often given sedation or anesthesia. The aim of this study was to examine whether children aged three to nine years could undergo MRI while awake and achieve adequate image quality if age-adjusted routines were used. A two-group controlled experimental design was used. Thirty-six children were assigned to a control group and underwent MRI with the prevalent routines. Thirty-three children were assigned to an intervention group and underwent the MRI while awake. The age-adjusted routine included a booklet and a story book, a model of the MRI scanner with the MRI sound, and a DVD film during the examination. In the control group, 30 children underwent the examination under anesthesia and 6 underwent the examination while they were awake. All had acceptable examinations. In the intervention group, 33 children had their examination while awake and 30 of them had acceptable examinations. The parents' satisfaction with the care was assessed to be equal or higher in the intervention group and the costs were calculated to be lower. Thus, many children receiving age-appropriate preparation and distraction can undergo MRI examinations while awake. © The Author(s) 2014.

  4. Effect of a pulsed magnetic field on permeability of the cornea and sorption properties of the tissue structures and refractive media of the eye

    International Nuclear Information System (INIS)

    Skrinnik, A.V.

    1986-01-01

    The author attempts to obtain direct proof of increased permeability of the cornea and enhanced sorption properties of the tissue structures and refractive media of the eye under the influence of a pulsed magnetic field (MF). In the course of the investigation, the method of radioactive indication of two substances ( 35 S-streptomycin and 75 Se-methionine), widely used in opthalmologic practice, was used. The radioactivity of the working solution of the preparations was 300,000 cpm in 0.1 ml. Changes in the permeability of the cornea were assessed on the basis of changes in radioactivity of the aqueous humor. The concentration of 35 S-streptomycin in aqueous humor of the animals immediately after exposure to MF was significantly higher than in the control. Analysis of permeability of the cornea for 75 Se-methionine also showed increased penetration of radioactivity into the aqueous. The results are evidence of the greater penetrating power of 75 Se-methionine

  5. Correlation between single-trial visual evoked potentials and the blood oxygenation level dependent response in simultaneously recorded electroencephalography-functional magnetic resonance imaging

    DEFF Research Database (Denmark)

    Fuglø, Dan; Pedersen, Henrik; Rostrup, Egill

    2012-01-01

    in different occipital and extraoccipital cortical areas not explained by the boxcar regressor. The results suggest that the P1-N2 regressor is the best EEG-based regressor to model the visual paradigm, but when looking for additional effects like habituation or attention modulation that cannot be modeled......To compare different electroencephalography (EEG)-based regressors and their ability to predict the simultaneously recorded blood oxygenation level dependent response during blocked visual stimulation, simultaneous EEG-functional magnetic resonance imaging in 10 healthy volunteers was performed....... The performance of different single-trial EEG regressors was compared in terms of predicting the measured blood oxygenation level dependent response. The EEG-based regressors were the amplitude and latency of the primary positive (P1) and negative (N2) peaks of the visual evoked potential, the combined P1-N2...

  6. A high-speed, multi-input serial-interfacing system for a computer with simultaneous back-up recording on magnetic tape

    International Nuclear Information System (INIS)

    Andeweg, A.H.

    1983-01-01

    A system has been developed that interfaces nuclear-instrument data modules and a multichannel analyser into a computer. The interface converts 4-bit binary-coded decimal (BCD) data into 8-bit packed BCD data, and converts the parallel data into serial data. The data are transmitted up to a distance of 500m at a transfer rate of 153,6kbaud via an RS422 transmission link to a central computer system. One or more multichannel analyser systems can be connected to the system via a routine device. The routing device serves these analysers on a first-come-first-served mode. The data transmitted to the computer system are recorded simultaneously on a digital magnetic-tape drive to provide a back-up facility

  7. The pros and cons of vaious optical media for the soldier's interfacility radiographic record (SIRR) in the combat casualty care system

    International Nuclear Information System (INIS)

    Kerlin, B.D.; Johnson, W.P.

    1989-01-01

    Ongoing research and evaluation projects sponsored by the Army Medical Research and Development Command are leading towards filmless radiography in the combat casualty care system of the 1990s. With the elimination of film, the question arises as to the most appropriate medium for archiving and transporting X-ray images and related patient data with the wounded between facilities. This paper considers the pros and cons of the various candidate media in relation to their specifications, availability, and appropriateness under simulated combat casualty care conditions

  8. The Pros And Cons Of Various Optical Media For The Soldier's Interfacility Radiographic Record (SIRR) In The Combat Casualty Care System

    Science.gov (United States)

    Kerlin, Barbara D.; Johnson, William P.

    1989-05-01

    Ongoing research and evaluation projects sponsored by the Army Medical Research and Development Command are leading towards filmless radiography in the combat casualty care system of the 1990s. With the elimination of film, the question arises as to the most appropriate medium for archiving and transporting x-ray images and related patient data with the wounded between facilities. This paper considers the pros and cons of the various candidate media in relation to their specifications, availability, and appropriateness under simulated combat casualty care conditions.

  9. Superconducting magnets

    International Nuclear Information System (INIS)

    1994-08-01

    This report discusses the following topics on superconducting magnets: D19B and -C: The next steps for a record-setting magnet; D20: The push beyond 10 T: Beyond D20: Speculations on the 16-T regime; other advanced magnets for accelerators; spinoff applications; APC materials development; cable and cabling-machine development; and high-T c superconductor at low temperature

  10. LDPC product coding scheme with extrinsic information for bit patterned media recoding

    Directory of Open Access Journals (Sweden)

    Seongkwon Jeong

    2017-05-01

    Full Text Available Since the density limit of the current perpendicular magnetic storage system will soon be reached, bit patterned media recording (BPMR is a promising candidate for the next generation storage system to achieve an areal density beyond 1 Tb/in2. Each recording bit is stored in a fabricated magnetic island and the space between the magnetic islands is nonmagnetic in BPMR. To approach recording densities of 1 Tb/in2, the spacing of the magnetic islands must be less than 25 nm. Consequently, severe inter-symbol interference (ISI and inter-track interference (ITI occur. ITI and ISI degrade the performance of BPMR. In this paper, we propose a low-density parity check (LDPC product coding scheme that exploits extrinsic information for BPMR. This scheme shows an improved bit error rate performance compared to that in which one LDPC code is used.

  11. LDPC product coding scheme with extrinsic information for bit patterned media recoding

    Science.gov (United States)

    Jeong, Seongkwon; Lee, Jaejin

    2017-05-01

    Since the density limit of the current perpendicular magnetic storage system will soon be reached, bit patterned media recording (BPMR) is a promising candidate for the next generation storage system to achieve an areal density beyond 1 Tb/in2. Each recording bit is stored in a fabricated magnetic island and the space between the magnetic islands is nonmagnetic in BPMR. To approach recording densities of 1 Tb/in2, the spacing of the magnetic islands must be less than 25 nm. Consequently, severe inter-symbol interference (ISI) and inter-track interference (ITI) occur. ITI and ISI degrade the performance of BPMR. In this paper, we propose a low-density parity check (LDPC) product coding scheme that exploits extrinsic information for BPMR. This scheme shows an improved bit error rate performance compared to that in which one LDPC code is used.

  12. Asymmetrical to symmetrical magnetic fabric of dykes: Paleo-flow orientations and Paleo-stresses recorded on feeder-bodies from the Motru Dyke Swarm (Romania)

    Science.gov (United States)

    Femenias, O.; Diot, H.; Berza, T.; Gauffriau, A.; Demaiffe, D.

    2003-04-01

    The fabric of crystals in a dyke is representative of the flow of magma, considered as a newtonian fluid. The AMS of the rocks (=magnetic mineralogy subfabric) gives a good representation of the shape preferred orientation related to the total fabric which, in turn is marker of the magmatic flow acquired during emplacement of the fluid within the dyke width. Generally, a symmetrical distribution of the fabric in terms of foliation and lineation across the dyke is in agreement with a model involving symmetrical differential displacements of the flow of the fluid within a channel. In this case, the flow direction is in relation with the imbrication of the symmetric foliations. In this study, we present the cases of both symmetrical and asymmetrical dyke fabric recording and involving different process of emplacement during a regional deformation. From a regional survey of a large Pan-African calc-alkaline dyke swarm (of basaltic-andesitic-dacitic-rhyolitic composition) of the Alpine Danubian window from South Carpathians of Romania, two populations of dykes have been described: thick (from 1 to 30 meters) N-S trending dykes and thin (less than 1 meter) E-W dykes. These two populations crosscut the country rocks without simple chronological relations between them. The thick dykes display asymmetrical fabric that involve a relatively long history of emplacement and important distance of flow. They record the regional sinistral movement of the walls. By contrast, the thin dykes are symmetrical and display frequently an arteritic morphology that limits the dyke length, with no cartographic extension. The mean orientations of the two types of dykes can be related to the same regional stress field and a continuum of emplacement is proposed for the two types of dykes during the regional deformation.

  13. Media education.

    Science.gov (United States)

    Strasburger, Victor C

    2010-11-01

    The American Academy of Pediatrics recognizes that exposure to mass media (eg, television, movies, video and computer games, the Internet, music lyrics and videos, newspapers, magazines, books, advertising) presents health risks for children and adolescents but can provide benefits as well. Media education has the potential to reduce the harmful effects of media and accentuate the positive effects. By understanding and supporting media education, pediatricians can play an important role in reducing harmful effects of media on children and adolescents.

  14. Feasibility of studying brain morphology in major depressive disorder with structural magnetic resonance imaging and clinical data from the electronic medical record: A pilot study

    Science.gov (United States)

    Hoogenboom, Wouter S.; Perlis, Roy H.; Smoller, Jordan W.; Zeng-Treitler, Qing; Gainer, Vivian S.; Murphy, Shawn N.; Churchill, Susanne E.; Kohane, Isaac S.; Shenton, Martha E.; Iosifescu, Dan V.

    2012-01-01

    For certain research questions related to long-term outcomes or to rare disorders, designing prospective studies is impractical or prohibitively expensive. Such studies could instead utilize clinical and magnetic resonance imaging data (MRI) collected as part of routine clinical care, stored in the electronic medical record (EMR). Using major depressive disorder (MDD) as a disease model, we examined the feasibility of studying brain morphology and associations with remission using clinical and MRI data exclusively drawn from the EMR. Advanced automated tools were used to select MDD patients and controls from the EMR who had brain MRI data, but no diagnosed brain pathology. MDD patients were further assessed for remission status by review of clinical charts. Twenty MDD patients (eight full-remitters, six partial-remitters, and six non-remitters), and fifteen healthy control subjects met all study criteria for advanced morphometric analyses. Compared to controls, MDD patients had significantly smaller right rostral-anterior cingulate volume, and level of non-remission was associated with smaller left hippocampus and left rostral-middle frontal gyrus volume. The use of EMR data for psychiatric research may provide a timely and cost-effective approach with the potential to generate large study samples reflective of the real population with the illness studied. PMID:23149041

  15. Asymmetrical to symmetrical magnetic fabric of dikes: Paleo-flow orientations and Paleo-stresses recorded on feeder-bodies from the Motru Dike Swarm (Romania)

    Science.gov (United States)

    Féménias, Olivier; Diot, Hervé; Berza, Tudor; Gauffriau, Antoine; Demaiffe, Daniel

    2004-08-01

    The fabric in a dike is representative of the magmatic flow, considered as Newtonian. The anisotropy of magnetic susceptibility of the rocks gives a good representation of the shape-preferred orientation which, in turn, is a marker of the magmatic flow. Generally, a symmetrical pattern of the fabric across the dike is in agreement with a flow of magma within a channel: the flow direction is then reliable with this imbrication. An asymmetrical fabric is dependent on the flow and displacement of the wall. We present the case of both symmetrical and asymmetrical dike fabrics recording different emplacements. From a Pan-African calc-alkaline dike swarm (of basaltic-andesitic-dacitic-rhyolitic composition) of the Alpine Danubian window from South Carpathians (Romania), two populations of dikes have been described: thick (1-30 m) N-S-trending dikes and thin (movement of the walls. In contrast, the thin dikes are symmetrical and frequently display an arteritic morphology that limits the dike length, with no cartographic extension. We propose to relate the two types of dikes to the same regional stress field in a continuum of emplacement during a regional brittle event.

  16. Maximum Acceleration Recording Circuit

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Coarsely digitized maximum levels recorded in blown fuses. Circuit feeds power to accelerometer and makes nonvolatile record of maximum level to which output of accelerometer rises during measurement interval. In comparison with inertia-type single-preset-trip-point mechanical maximum-acceleration-recording devices, circuit weighs less, occupies less space, and records accelerations within narrower bands of uncertainty. In comparison with prior electronic data-acquisition systems designed for same purpose, circuit simpler, less bulky, consumes less power, costs and analysis of data recorded in magnetic or electronic memory devices. Circuit used, for example, to record accelerations to which commodities subjected during transportation on trucks.

  17. Magnetic Hysteresis

    CERN Document Server

    Della Torre, Edward

    2000-01-01

    Understanding magnetic hysteresis is vitally important to the development of the science of magnetism as a whole and to the advancement of practical magnetic device applications. Magnetic Hysteresis, by acclaimed expert Edward Della Torre, presents a clear explanation of the connection between physical principles and phenomenological hysteresis. This comprehensive book offers a lucid analysis that enables the reader to save valuable time by reducing trial-and-error design. Dr. Della Torre uses physical principles to modify Preisach modeling and to describe the complex behavior of magnetic media. While Pretsach modeling is a useful mathematical tool, its congruency and deletion properties present limitations to accurate descriptions of magnetic materials. Step-by-step, this book describes the modifications that can overcome these limitations. Special attention is given to the use of feedback around a Preisach transducer to remove the congruency restriction, and to the use of accommodation and aftereffect model...

  18. Revised Late Oligocene to Early Miocene magnetic stratigraphy recorded by drift sediments at Sites U1405 and U1406, IODP Expedition 342 (Newfoundland, NW Atlantic)

    Science.gov (United States)

    van Peer, Tim; Xuan, Chuang; Wilson, Paul; Liebrand, Diederik; Lippert, Peter

    2015-04-01

    to impact the completeness of the spliced magnetostratigraphic record. Rock and mineral magnetic studies of selected samples are currently ongoing to characterise the magnetic mineralogy of the sediments and how it changes across the stratigraphic gaps and intervals with contrasting lithological and/or palaeomagnetic properties. These data will help us understand the origin of the palaeomagnetic signal and test its reliability, while providing insights on the nature of the observed stratigraphic gaps and how they relate to global climate dynamics of the OMT and the Deep Western Boundary Current.

  19. The nitrogen doping effect on the properties of Ge-In-Sb-Te phase-change recording media investigated by blue-light laser

    International Nuclear Information System (INIS)

    Yeh, T.-T.; Hsieh, T.-E.; Shieh, H.-P.D.

    2005-01-01

    This work investigates the thermal, optical and recrystallization properties as well as the microstructure of nitrogen-doped Ge-In-Sb-Te (GIST) phase-change material when irradiated by blue-light laser. The experimental results showed that nitrogen doping at the condition of N 2 /Ar sputtering gas flow ratio equals to 3% might enhance the recrystallization speed of GIST recording layer up to 1.5 times. However, the disk failed when too much nitrogen (N 2 /Ar ≥ 5.0%) was introduced. The data obtained by differential scanning calorimetry, X-ray diffraction and ellipsometry revealed changes of thermal and optical properties due to the nitrogen doping in GIST. When appropriate amount of nitrogen was added, the activation energy (E a ) of amorphous-crystalline phase transition of GIST decreased and the optical constants of amorphous and crystalline phases (except the k value of amorphous phase) gradually reduced with the increase of wavelength in the range of 600-750 nm. Modulation simulation based on the reflectively of doped GIST layers obtained from static test indicated that appropriate nitrogen doping benefited the signal characteristics of optical disks. Transmission electron microscopy observed numerous tiny precipitates uniformly distributed in the doped GIST layers. These were believed to be nitride particles generated by nitrogen doping that might offer the preferential sites for amorphous-crystalline phase transition so that the recrystallization speed was accelerated

  20. Making Media Studies

    Directory of Open Access Journals (Sweden)

    David Gauntlett

    2015-12-01

    Full Text Available This podcast is a recording of a research seminar that took place on December 3, 2015, at the University of Westminster's Communication and Media Research Institute (CAMRI. In this contribution, David Gauntlett discusses his new book, Making Media Studies, and other new work. In Making Media Studies (Peter Lang, 2015, Gauntlett proposes a vision of media studies based around doing and making – not about the acquisition of skills, as such, but an experience of building knowledge and understanding through creative hands-on engagement with all kinds of media. Gauntlett suggests that media studies scholars have failed to recognise the significance of everyday creativity – the vital drive of people to make, exchange, and learn together, supported by online networks. He argues that we should think about media in terms of conversations, inspirations, and making things happen. Media studies can be about genuine social change, he suggests, if we recognise the significance of everyday creativity, work to transform our tools, and learn to use them wisely. David Gauntlett is a Professor in the School of Media, Arts and Design at the University of Westminster, where he is also the School's Co-Director of Research. He is the author of several books, including: Creative Explorations (2007, Media, Gender and Identity: An Introduction (2nd edition 2008, Making is Connecting (2011, and Making Media Studies (2015. He has made a number of popular online resources, videos and playthings, and has pioneered creative research and workshop methods. He is external examiner for Information Experience Design at the Royal College of Art, London.

  1. ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group

    Science.gov (United States)

    Kitagawa, Kakuya; Tsai, I-Chen; Chan, Carmen; Yu, Wei; Yong, Hwan Seok; Choi, Byoung Wook

    2010-01-01

    The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging. PMID:20931289

  2. Microelectrode Recording-Guided Versus Intraoperative Magnetic Resonance Imaging-Guided Subthalamic Nucleus Deep Brain Stimulation Surgery for Parkinson Disease: A 1-Year Follow-Up Study.

    Science.gov (United States)

    Liu, Xuemeng; Zhang, Jibo; Fu, Kai; Gong, Rui; Chen, Jincao; Zhang, Jie

    2017-11-01

    Microelectrode recording (MER) and intraoperative magnetic resonance imaging (iMRI) have been used in deep brain stimulation surgery for Parkinson disease (PD), but comparative methodology is lacking. Therefore, we compared the 1-year follow-up outcomes of MER-guided and iMRI-guided subthalamic nucleus (STN) deep brain stimulation (DBS) surgery in PD patients. We conducted a review comparing PD patients who underwent MER-guided (n = 76, group A) and iMRI-guided STN DBS surgery (n = 61, group B) in our institution. Pre- and postoperative assessments included Unified Parkinson's Disease Rating Scale-III (UPDRS-III) score, Parkinson's Disease Questionnaire (PDQ-39), Mini-Mental State Examination (MMSE), levodopa equivalent daily doses (LEDDs), and magnetic resonance images. The mean magnitudes of electrode discrepancy were x = 1.1 ± 0.2 mm, y = 1.3 ± 0.3 mm, and z = 2.1 ± 0.5 mm in group A and x = 1.3 ± 0.4 mm, y = 1.2 ± 0.2 mm, and z = 2.5 ± 0.7 mm in group B. Significant differences were not found between 2 groups for x, y, or z (P = 0.34, P = 0.26, and P = 0.41, respectively). At 1 year, when levodopa was withdrawn for 12 hours, the UPDRS-III score improved by 66.3% ± 13.5% in group A and 64.8% ± 12.7% in group B (P = 0.24); the PDQ-39 summary index score improved by 49.7% ± 14.3% in group A and 44.1% ± 12.7% in group B (P = 0.16); the MMSE score improved by 4.2% ± 2.1% in group A and 11.1% ± 3.2% in group B (P = 0.43); and LEDDs decreased by 48.7% ± 10.1% in group A and 56.9% ± 12.0% in group B (P = 0.32). MER and iMRI both are effective ways to ensure adequate electrode placement in DBS surgery, but there is no superiority between both techniques, at least in terms of 1-year follow-up outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Nanopatterning of magnetic disks by single-step Ar+ Ion projection

    NARCIS (Netherlands)

    Dietzel, A.H.; Berger, R.; Loeschner, H.; Platzgummer, E.; Stengl, G.; Bruenger, W.H.; Letzkus, F.

    2003-01-01

    Large-area Ar+ projection has been used to generate planar magnetic nanostructures on a 1¿-format hard disk in a single step (see Figure). The recording pattern was transferred to a Co/Pt multilayer without resist processes or any other contact to the delicate media surface. It is conceivable that

  4. Media Komunitas dan Media Literacy

    Directory of Open Access Journals (Sweden)

    Pawito .

    2013-12-01

    Full Text Available Abstract:This essay deals with community media in relation to media literacy. After a short discussion on a number of community media characters is made the essay goes further with somewhat detail theoretical presumptions of the roles of media community with respect primarily to the development as Amartya Sen mentioned about. The author suggests that community media may play some significant roles in the development including (a disseminating information (from varieties of perspective, (b facilitating public discussion, (c helping to reach solutions of problems, (d encouraging participations, and (e encouraging the development of media literacy. Regarding the last point the author remarks that media community may have a dual-roles i.e facilitating community’s member in media participation and facilitating community’s member in media education.

  5. Deccan volcanism induced high-stress environment during the Cretaceous-Paleogene transition at Zumaia, Spain: Evidence from magnetic, mineralogical and biostratigraphic records

    Science.gov (United States)

    Font, Eric; Adatte, Thierry; Andrade, Mariana; Keller, Gerta; Mbabi Bitchong, André; Carvallo, Claire; Ferreira, Joana; Diogo, Zenaida; Mirão, José

    2018-02-01

    We conducted detailed rock magnetic, mineralogical and geochemical (mercury) analyses spanning the Cretaceous-Paleogene boundary (KPB) at Zumaia, Spain, to unravel the signature of Deccan-induced climate and environmental changes in the marine sedimentary record. Our biostratigraphic results show that Zumaia is not complete, and lacks the typical boundary clay, zone P0 and the base of zone P1a(1) in the basal Danian. Presence of an unusual ∼1m-thick interval spanning the KPB is characterized by very low detrital magnetite and magnetosome (biogenic magnetite) contents and by the occurrence of akaganéite, a very rare mineral on Earth in oxidizing, acidic and hyper-chlorinated environments compatible with volcanic settings. These benchmarks correlate with higher abundance of the opportunist Guembelitria cretacea species. Detrital magnetite depletion is not linked to significant lithological changes, suggesting that iron oxide dissolution by acidification is the most probable explanation. The concomitant decrease in magnetosomes, produced by magnetotactic bacteria at the anoxic-oxic boundary, is interpreted as the result of changes in seawater chemistry induced by surficial ocean acidification. Mercury peaks up to 20-50 ppb are common during the last 100 kyr of the Maastrichtian (zone CF1) but only one significant anomaly is present in the early Danian, which is likely due to the missing interval. Absence of correlation between mercury content (R2 = 0.009) and total organic carbon (R2 = 0.006) suggest that the former originated from the Deccan Traps eruptions. No clear relation between the stratigraphic position of the mercury peaks and the magnetite-depleted interval is observed, although the frequency of the mercury peaks tends to increase close to the KPg boundary. In contrast to Bidart (France) and Gubbio (Italy), where magnetite depletion and akaganéite feature within a ∼50cm-thick interval located 5 cm below the KPg boundary, the same benchmarks are

  6. Review on the progress in synthesis and application of magnetic carbon nanocomposites

    Science.gov (United States)

    Zhu, Maiyong; Diao, Guowang

    2011-07-01

    This review focuses on the synthesis and application of nanostructured composites containing magnetic nanostructures and carbon-based materials. Great progress in fabrication of magnetic carbon nanocomposites has been made by developing methods including filling process, template-based synthesis, chemical vapor deposition, hydrothermal/solvothermal method, pyrolysis procedure, sol-gel process, detonation induced reaction, self-assembly method, etc. The applications of magnetic carbon nanocomposites expanded to a wide range of fields such as environmental treatment, microwave absorption, magnetic recording media, electrochemical sensor, catalysis, separation/recognization of biomolecules and drug delivery are discussed. Finally, some future trends and perspectives in this research area are outlined.

  7. Longitudinal recording on FePt and FePtX (X = B, Ni) intermetallic compounds

    Science.gov (United States)

    Li, Ning

    1999-11-01

    Near field recording on high coercivity FePt intermetallic compound media using a high Bsat write element was investigated. Untextured FePt media were prepared by magnetron sputtering on ZrO2 disks at a substrate temperature of 450°C, with post annealing at 450°C for 8 hrs. Both multilayer and cosputtered precursors produced the ordered tetragonal L10 phase with high coercivity between 5kOe and 12kOe. To improve readback noise decrease magnetic domain size, FePtB media were subsequently prepared by cosputtering. Over-write, roll-off, signal to noise ratio and non-linear transition shift (NLTS) ere measured by both metal in gap (MIG) and merged MR heads. FePtB media showed similar NLTS to commercial CoCrPtTa longitudinal media, but 5dB lower signal to noise ratio. By operating recording transducers in near contact, reasonable values of (>30dB) could be obtained. VSM Rotational Transverse Magnetization has been used for measuring the anisotropy field of magnetic thin films. Magnetization reversal during rotation of a 2D isotropic an applied field is discussed. The relationship between the transverse magnetization My and the applied field H was numerically solved. An excellent approximation for the transverse magnetization is found to be: My/Ms=A(1- H/Hk) 2.5, where A = 1.1434, and Hk is the anisotropy field. For curve fitting to experimental data, both A and Hk were used as fitting parameters. Comparison between a constructed torque hysteresis method and this VSM RTM method have been made theoretically and experimentally. Both results showed that VSM RTM will give better extrapolation of the anisotropy field. The torque measurement will slightly overestimate the anisotropy field. The anisotropy fields of FePt and FePtX (X = B, Ni) films were characterized using this VSM RTM technique with comparison to a CoCrTaPt disk. Anisotropy energy was derived. Hc/Hk was used as an indicator for coherent rotation of a single domain. Interactions between magnetic domains were

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... immediately after the exam. A few patients experience side effects from the contrast material, including nausea and local ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  10. Locative media

    CERN Document Server

    Wilken, Rowan

    2014-01-01

    Not only is locative media one of the fastest growing areas in digital technology, but questions of location and location-awareness are increasingly central to our contemporary engagements with online and mobile media, and indeed media and culture generally. This volume is a comprehensive account of the various location-based technologies, services, applications, and cultures, as media, with an aim to identify, inventory, explore, and critique their cultural, economic, political, social, and policy dimensions internationally. In particular, the collection is organized around the perception that the growth of locative media gives rise to a number of crucial questions concerning the areas of culture, economy, and policy.

  11. Media Entrepreneurship

    DEFF Research Database (Denmark)

    Khajeheian, Datis

    2017-01-01

    Media Entrepreneurship has been an ambiguous, unclear and controversial concept and despite of growing academic efforts in the last decade, it is still a poorly defined subject. This paper is an effort to fill this gap by providing a comprehensive definition of media entrepreneurship. Firstly......, a literature review conducted and entrepreneurship, media, opportunity and innovation as building blocks of media entrepreneurship explained. Then by using of a mixed of bibliographic method and a Delphi method with multi-stage analysis process, a consensual definition of media entrepreneurship proposed...... entrepreneurship....

  12. Media Framing

    DEFF Research Database (Denmark)

    Pedersen, Rasmus T.

    2017-01-01

    The concept of media framing refers to the way in which the news media organize and provide meaning to a news story by emphasizing some parts of reality and disregarding other parts. These patterns of emphasis and exclusion in news coverage create frames that can have considerable effects on news...... consumers’ perceptions and attitudes regarding the given issue or event. This entry briefly elaborates on the concept of media framing, presents key types of media frames, and introduces the research on media framing effects....

  13. Micromagnetic studies for bit patterned media above 2 Tbit/in.2

    International Nuclear Information System (INIS)

    Zhang Kaiming; Wei Dan

    2012-01-01

    Bit patterned media (BPM) recording is a candidate for extremely high density magnetic recording. A micromagnetic model is built up to analyze the phase diagram of the correct-write-in condition in BPM above 2 Tb/in. 2 fabricated by lithography or ion irradiation methods. The target of the study is to acquire the relationship between the recording performance and the magnetic properties of the media. The medium includes the polycrystalline grains and grain boundary. In BPM fabricated by lithography with FCT structure, two phase diagrams of the correct-write-in condition are found for the anisotropy angular distribution Δθ, the ratio of tetragonal anisotropy K 22 to uniaxial anisotropy K 1 and the uniaxial anisotropy distribution ΔK 1 . In BPM fabricated by ion irradiation methods, two phase diagrams of the correct-write-in condition are analyzed for the ratio of saturation magnetization M' s /M s , anisotropy field H' k /H k and the exchange field H' ex /H ex in the ion irradiated region and the bit islands. - Research highlights: → Two types of BPM, regular or with irradiated regions, are studied using micromagnetics. → Optimum parameters are found for regular BPM with non-magnetic inter-bit spacing. → Recording phase diagrams versus M s , H k and A * in irradiated regions are found.

  14. Multiple oxide content media for columnar grain growth in L10 FePt thin films

    International Nuclear Information System (INIS)

    Ho, Hoan; Yang, En; Laughlin, David E.; Zhu, Jian-Gang

    2013-01-01

    An approach to enhance the height-to-diameter ratio of FePt grains in heat-assisted magnetic recording media is proposed. The FePt-SiO x thin films are deposited with a decrease of the SiO x percentage along the film growth direction. When bi-layer and tri-layer media are sputtered at 410 °C, we observe discontinuities in the FePt grains at interfaces between layers, which lead to poor epitaxial growth. Due to increased atomic diffusion, the bi-layer media sputtered at 450 °C is shown to (1) grow into continuous columnar grains with similar size as single-layer media but much higher aspect ratio, (2) have better L1 0 ordering and larger coercivity.

  15. Effects of array arrangements in nano-patterned thin film media

    International Nuclear Information System (INIS)

    El-Hilo, M.

    2010-01-01

    In this work, the effect of different arrays arrangements on the magnetic behaviour of patterned thin film media is simulated. The modeled films consist of 80x80 cobalt grains of uniform diameter (20 nm) distributed into two different array arrangement: hexagonal (triangular) or square arrays. In addition to that, for each array arrangement, two cases of anisotropy orientations, random and textured films are considered. For both array arrangements and media orientations, hysteresis loops at different array separation (d) were simulated. Predictions show that for closely packed films, the shearing effects on the magnetization loop are much larger for the square array arrangement than the hexagonal one. According to these predictions, the bit switching field distribution in interacting 2D systems is much narrower for the hexagonal array arrangement. This result could be very important for high-density magnetic recording where a narrow bit switching field distribution is required.

  16. Sensitive Media

    Directory of Open Access Journals (Sweden)

    Malinowska Anna

    2017-12-01

    Full Text Available The paper engages with what we refer to as “sensitive media,” a concept associated with developments in the overall media environment, our relationships with media devices, and the quality of the media themselves. Those developments point to the increasing emotionality of the media world and its infrastructures. Mapping the trajectories of technological development and impact that the newer media exert on human condition, our analysis touches upon various forms of emergent affect, emotion, and feeling in order to trace the histories and motivations of the sensitization of “the media things” as well as the redefinition of our affective and emotional experiences through technologies that themselves “feel.”

  17. Media Ecology

    Directory of Open Access Journals (Sweden)

    Marina Ašković

    2015-05-01

    Full Text Available Does the trend in which electronic media are gradually becoming extension of human body have to move towards full enslavement of a human and his personality, or the same human will unpredictably, with the aid of his personal media literacy, exit the whirls of media and technological censorships? Personality crisis is closely related to the crisis of language no matter how contradicted to global ideology of transnational transhumanism it may seem. Considering the fact that recent media presentations of the world are based on commercialization of environmentalism, philosophical and aesthetic thought appears as an important subject of ecology. As media mediates, the scenery of civilized living increasingly becomes more appealing even though it derives from commercial and political background. Consequently, the future of humanity depends by large on the philosophy of media. Media have to truly ecologise returning the humanum to its essence making it into the extension of the natural world.

  18. Vintage Vinyl Record Design

    Science.gov (United States)

    Sacco, Michael

    2008-01-01

    In this article, the author describes a project in which his ninth-grade art students utilized a vinyl record as an unusual medium to create a work that exhibited solid design, great creativity, and strong craftsmanship. Students presented their pieces to the class for critique, explained the process, the media, and their feelings about their…

  19. A facile approach for screening isolated nanomagnetic behavior for bit-patterned media

    International Nuclear Information System (INIS)

    Thiyagarajah, Naganivetha; Ng, Vivian; Asbahi, Mohamed; Yakovlev, Nikolai L; Yang, Joel K W; Wong, Rick T J; Low, Kendrick W M

    2014-01-01

    Bit-patterned media (BPM) fabricated by the direct deposition of magnetic material onto prepatterned arrays of nanopillars is a promising approach for increasing magnetic recording of areal density. One of the key challenges of this approach is to identify and control the magnetic interaction between the bits (on top of the nanopillars) and the trench material between the pillars. Using independent techniques, including magnetic force microscopy, the variable-angle magneto-optic Kerr effect, and remanence curves, we were able to determine the presence and relative intensities of exchange and dipolar interactions in Co-Pd multilayer-based BPM fabricated by direct deposition. We found that for pitches of 30 nm or less, there were negligible exchange interactions, and the bits were found to be magnetically isolated. As we move to higher densities, the absence of exchange interactions indicates that direct deposition is a promising approach to BPM fabrication. (papers)

  20. A 15,400-year record of environmental magnetic variations in sub-alpine lake sediments from the western Nanling Mountains in South China: Implications for palaeoenvironmental changes

    Science.gov (United States)

    Zhong, Wei; Wei, Zhiqiang; Shang, Shentan; Ye, Susu; Tang, Xiaowen; Zhu, Chan; Xue, Jibin; Ouyang, Jun; Smol, John P.

    2018-04-01

    A detailed environmental magnetic investigation has been performed on a sub-alpine sedimentary succession deposited over the past 15,400 years in Daping Swamp in the western Nanling Mountains of South China. Magnetic parameters reveal that fine grains of pseudo-single domain (PSD) magnetite or titanomagnetite are the dominant magnetic minerals in the lake sediments and surface soils collected from the catchment, which suggests that magnetic minerals in lake sediments mainly originated from surface soil erosion of the catchment. Variation of surface runoff caused by rainfall is interpreted as the main process for transportation of weathered soils into the lake. In the Last Deglacial period (LGP, 15,400-11,500 cal a BP), the influx of magnetic minerals of detrital material may have been significantly affected by the severe dry and cold conditions of the Last Glacial Maximum. Stabilised conditions of the catchment associated with increased vegetation coverage (e.g., 8000-4500 and 2500-1000 cal a BP) limited the input of magnetic minerals. Intensive soil erosion caused by increased human activity may have given rise to abnormal increases in multiple magnetic parameters after 1000 cal a BP. Because changes in runoff and vegetation coverage are closely related to Asian summer monsoon (ASM) intensity, the sedimentary magnetism of Daping Swamp provides another source of information to investigate the evolution of the ASM.

  1. Correlation Between Bile Reflux Gastritis and Biliary Excreted Contrast Media in the Stomach.

    Science.gov (United States)

    Hyun, Jong Jin; Yeom, Suk Keu; Shim, Euddeum; Cha, Jaehyung; Choi, Inyoung; Lee, Seung Hwa; Chung, Hwan Hoon; Cha, Sang Hoon; Lee, Chang Hee

    This study aimed to evaluate the relationship between biliary excreted contrast media in the stomach and the presence of bile reflux gastritis. Consecutive 111 patients who underwent both gadoxetic acid-enhanced magnetic resonance cholangiography (gadoxetic MRC) and gastric endoscopy were included in this study. We performed a review of the gadoxetic-MRC image sets acquired 60 minutes after intravenous injection of contrast media and endoscopic images. We recorded amount of contrast media in the stomach. The sensitivity, specificity, and accuracy of duodenogastric bile reflux diagnosis were evaluated for the gadoxetic MRC. Statistical analysis was performed using the Fisher exact test and the linear-by-linear association test. Among the 111 patients, 39 had 60-minute delayed images showing the presence of contrast media in the stomach. Of these 39 patients, 13 had bile reflux gastritis and 5 showed bile in the stomach without evidence of erythematous gastritis. Of the 72 patients who did not show contrast media in the stomach, none had bile reflux gastritis and 2 patients showed bile staining in the stomach without evidence of erythematous gastritis. Bile reflux gastritis was significantly more frequent in patients with contrast media in the stomach on gadoxetic MRC than in those without. Patients with high-grade extension of contrast media in the stomach had significantly frequent bile reflux gastritis than did those with low-grade extension. Biliary excreted contrast media in the stomach on 60-minute delayed gadoxetic MRC has a correlation with the presence of bile reflux gastritis on endoscopic examination.

  2. STUDY OF REUSABLE PHOTOSENSITIVE ELECTRON RECORDING MEDIA

    Science.gov (United States)

    a low molecular weight polystyrene resin (Dow Ps-2) is most suitable. The first photodielectrically deformed picture of a course bar pattern is reported using CdSe:Cu powder dispersed in carnauba wax . (Author)

  3. Analytical and computational study of magnetization switching in kinetic Ising systems with demagnetizing fields

    DEFF Research Database (Denmark)

    Richards, H.L.; Rikvold, P.A.

    1996-01-01

    particularly promising as materials for high-density magnetic recording media. In this paper we use analytic arguments and Monte Carlo simulations to quantitatively study the effects of the demagnetizing field on the dynamics of magnetization switching in two-dimensional, single-domain, kinetic Ising systems....... For systems in the weak-field ''stochastic region,'' where magnetization switching is on average effected by the nucleation and growth of a single droplet, the simulation results can be explained by a simple model in which the free energy is a function only of magnetization. In the intermediate......-field ''multidroplet region,'' a generalization of Avrami's law involving a magnetization-dependent effective magnetic field gives good agreement with the simulations. The effects of the demagnetizing field do not qualitatively change the droplet-theoretical picture of magnetization switching in highly anisotropic...

  4. Media Flow

    DEFF Research Database (Denmark)

    Kabel, Lars

    2016-01-01

    News and other kinds of journalistic stories, 16-17 hours a day, all year round, on all platforms, also the moderated social media. The key research thesis behind this article is that the continuous and speedy stream of news stories and media content now is becoming the centre of the production...... processes and the value creation in converged multimedia newsrooms. The article identify new methods and discuss editorial challenges in handling media flow....

  5. Fluvial influx and weathering history of the Himalayas since Last Glacial Maxima - Isotopic, sedimentological and magnetic records from the Bay of Bengal

    Digital Repository Service at National Institute of Oceanography (India)

    Chauhan, O.S.; Patil, S.K.; Suneethi, J.

    From temporal variations in stable isotopes, mineral magnetism, clay minerals and granulometric parameters from a sup(14) C dated core have been used to understand weathering history and influence of climate on the terrigenous fluxes into the Bay...

  6. Superconducting magnets 1992

    International Nuclear Information System (INIS)

    1993-06-01

    This report discusses the following topics on Superconducting Magnets; SSC Magnet Industrialization; Collider Quadrupole Development; A Record-Setting Magnet; D20: The Push Beyond 10T; Nonaccelerator Applications; APC Materials Development; High-T c at Low Temperature; Cable and Cabling-Machine Development; and Analytical Magnet Design

  7. MRI and intraocular tamponade media

    International Nuclear Information System (INIS)

    Manfre, I.; Fabbri, G.; Avitabile, T.; Biondi, P.; Reibaldi, A.; Pero, G.

    1993-01-01

    Thirteen patients who underwent surgery for retinal detachment and injection of intraocular tamponade media (silicone oil, flurosilicone oil, or perfluoro-carbon liquid) underwent magnetic resonance imaging (MRI), using spin-echo T1- and T2-weighted images. The ophthalmic tamponade media showed different signal intensity, according to their chemical structure. Unlike ophthalmoscopy or ultrasonography, MRI showed no oil-related artefact, making possible recognition of recurrent retinal detachment. (orig.)

  8. MRI and intraocular tamponade media

    Energy Technology Data Exchange (ETDEWEB)

    Manfre, I. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy)); Fabbri, G. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy)); Avitabile, T. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Biondi, P. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Reibaldi, A. (Inst. of Ophthalmology, Univ. of Catania (Italy)); Pero, G. (Dept. of Neuroradiology, Inst. of Neurosurgery, Univ. of Catania (Italy))

    1993-05-01

    Thirteen patients who underwent surgery for retinal detachment and injection of intraocular tamponade media (silicone oil, flurosilicone oil, or perfluoro-carbon liquid) underwent magnetic resonance imaging (MRI), using spin-echo T1- and T2-weighted images. The ophthalmic tamponade media showed different signal intensity, according to their chemical structure. Unlike ophthalmoscopy or ultrasonography, MRI showed no oil-related artefact, making possible recognition of recurrent retinal detachment. (orig.)

  9. Instructional Media

    African Journals Online (AJOL)

    This can be summed up in a few words: Students can learn a great deal from any of the media. Under most of the conditions tested, they could learn as much as from ... Beyond physical conditions (deafness) there is little reason to expect a differential media. Scientia Militaria, South African Journal of Military Studies, Vol 13 ...

  10. Mixed Media

    Science.gov (United States)

    Peterson, Erin

    2010-01-01

    While institutions do not often have a hook as compelling as an eagerly awaited movie, great content is critical for media relations success--and coupling it with the right distribution channel can ensure the story finds the right audience. Even better, retooling it for several media platforms can extend the life and reach of a story. The changes…

  11. Media darling

    CERN Multimedia

    Chalmers, Matthew

    2008-01-01

    He is the media-friendly face of particle physics, appearing on countless TV and radio shows in the run-up to the opening of CERN's Large Hadron Collider. Matthew Chalmers discovers how Brian Cox finds the time to be both a physicist and a media personality. (2 pages)

  12. Media Art

    DEFF Research Database (Denmark)

    Ekman, Ulrik

    2015-01-01

    environments, experience time, and develop identities individually and socially. Interviews with working media artists lend further perspectives on these cultural transformations. Drawing on cultural theory, new media art studies, human-computer interaction theory, and software studies, this cutting-edge book...... critically unpacks the complex ubiquity-effects confronting us every day....

  13. Media violence.

    Science.gov (United States)

    Cantor, J

    2000-08-01

    Research on the effects of media violence is not well understood by the general public. Despite this fact, there is an overwhelming consensus in the scientific literature about the unhealthy effects of media violence. Meta-analyses show that media-violence viewing consistently is associated with higher levels of antisocial behavior, ranging from the trivial (imitative violence directed against toys) to the serious (criminal violence), with many consequential outcomes in between (acceptance of violence as a solution to problems, increased feelings of hostility, and the apparent delivery of painful stimulation to another person). Desensitization is another well-documented effect of viewing violence, which is observable in reduced arousal and emotional disturbance while witnessing violence, the reduced tendency to intervene in a fight, and less sympathy for the victims of violence. Although there is evidence that youth who are already violent are more likely to seek out violent entertainment, there is strong evidence that the relationship between violence viewing and antisocial behavior is bidirectional. There is growing evidence that media violence also engenders intense fear in children which often lasts days, months, and even years. The media's potential role in solutions to these problems is only beginning to be explored, in investigations examining the uses and effects of movie ratings, television ratings, and the V-chip, and the effects of media literacy programs and public education efforts. Future research should explore important individual differences in responses to media violence and effective ways to intervene in the negative effects.

  14. Structural and Magnetic Behavioral Improvisation of Nanocalcium Hexaferrites

    Energy Technology Data Exchange (ETDEWEB)

    Sable, Sharad N., E-mail: sharadtz@hotmail.co [Department of Applied Physics, Priyadarshini College of Engineering, Nagpur (India); Rewatkar, Kishor G. [Department of Physics, Dr. Ambedkar College, Dikshabhumi, Nagpur (India); Nanoti, Vivek M. [Priyadarshini College of Engineering, Nagpur (India)

    2010-04-15

    In modern technoscientific era, the industrial application of nanomaterials has grabbed a paramount importance owing to their improved characteristics. Hexagonal ferrites especially M-type ferrites have been proved to be the promising candidates for nanomaterials by virtue of their ease of applicability in high density recording media, microwave absorption devices, magneto-optic recording media, etc. Keeping a bird's view over, the samples of varied combinations of M-type substituted hexaferrites are synthesized using sol-gel combustion route by blending nitrates and chlorides as oxidants accompanied with fuels like urea, glycine, citric acid, etc. as reducing agents. The substitution of Co{sup 2+} and Sn{sup 4+} ions lie essentially in the octahedral and tetrahedral sites. As the Fe{sup 3+} ions are being replaced by Co{sup 2+} and Sn{sup 4+} ions, the probability of having oxygen vacancies in the structure was found to be greatly reduced. The magnetic particles produced by conventional solid state reactions are often larger than those produced by sol-gel combustion route. Larger particles of magnetic oxides generally exhibit multidomain magnetic structure whereas nanosized particles generally exhibit single domain magnetic structure. The simultaneous or coupled divalent and tetravalent substitution of Co{sup 2+} and Sn{sup 4+} for Fe{sup 3+} ions greatly helps to improvise the magnetic parameters such as Curie temperature, coercivity, remanent magnetization, saturation magnetization, etc. The structural comparison is being analyzed through the XRD, TEM. The samples so synthesized are found to be reseasonably homogeneous and the average particle size of the sample synthesized is found to be in the nanorange. The structural and magnetic properties are observed be improved upon those of the samples reported earlier. This confirms the more viability of such samples in the various applications of digital data devices. Further attempts could possibly lead to

  15. Magnetism in heterogeneous thin film systems: Resonant X-ray scattering studies

    International Nuclear Information System (INIS)

    Kortright, J.B.; Jiang, J.S.; Bader, S.D.; Hellwig, O.; Marguiles, D.T.; Fullerton, E.E.

    2002-01-01

    Magnetic and chemical heterogeneity are common in a broad range of magnetic thin film systems. Emerging resonant soft x-ray scattering techniques are well suited to resolve such heterogeneity at relevant length scales. Resonant x-ray magneto-optical Kerr effect measurements laterally average over heterogeneity but can provide depth resolution in different ways, as illustrated in measurements resolving reversible and irreversible changes in different layers of exchange-spring heterostructures. Resonant small-angle scattering measures in-plane heterogeneity and can resolve magnetic and chemical scattering sources in different ways, as illustrated in measurements of granular alloy recording media

  16. FY1995 study of high density near-contact magnetic recording using spin valve head; 1995 nendo spin valve head ni yoru chokomitsudo near contact jiki kiroku no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Development of high performance spin valves formed by amorphous magnetic layer and head-medium interface with nano-thickness molecular film for realizing an ultra-high density of 20 Gbit/in{sup 2} using contact recording. The giant magnetoresistance effect was investigated for spin valves using very thin amorphous magnetic layer. In amorphous-CoFeB/Cu/ Co spin valves, the maximum MR ratio of 6% was achieved at the thickness of the amorphous layer of 2 nm. The spin valves with the amorphous layer exhibit very good thermal stability. Design guideline for molecularly thin lubricant was established using newly derived lubrication equation considering lubricant porosity. Novel method for accurately measuring surface force due to molecularly thin lubricant was developed by using Michelson interferometry to detect cantilever displacement, which enabled two-dimensional transient force measurement. (NEDO)

  17. The first module of CMS superconducting magnet is leaving towards CERN: a huge solenoid, which will hold the world record of stored energy

    CERN Multimedia

    2004-01-01

    The first module of the five which will make up the CMS superconducting magnet is sailing today from Genova port to CERN. The CMS (Compact Muon Solenoid) is one of the experiments that will take place at the accelerator LHC. The device will arrive after 10-days of travel (1 page)

  18. A mineral magnetic and scaled-chrysophyte paleolimnological study of two northeastern Pennsylvania lakes: records of fly ash deposition, land-use change and paleorainfall variation

    International Nuclear Information System (INIS)

    Kodama, K.P.; Lyons, J.C.; Silver, P.A.; Lott, A.M.

    1997-01-01

    A combined mineral magnetic and scaled chrysophyte study of lake sediments from Lake Lacawac and Lake Giles in northeastern Pennsylvania was conducted to determined the effects of land-use and sediment source changes on the variation of pH, conductivity, and alkalinity inferred from biotic changes

  19. Michael Faraday, media man.

    Science.gov (United States)

    Fara, Patricia

    2006-03-01

    Michael Faraday was an enthusiastic portrait collector, and he welcomed the invention of photography not only as a possible means of recording observations accurately, but also as a method for advertising science and its practitioners. This article (which is part of the Science in the Industrial Revolution series) shows that like many eminent scientists, Faraday took advantage of the burgeoning Victorian media industry by posing in various roles.

  20. 75 FR 21260 - Privacy Act of 1974; System of Records

    Science.gov (United States)

    2010-04-23

    ... records in the system: Storage: Paper records and electronic storage media. Retrievability: Name, Social... include name, Social Security Number (SSN), enlisted service number, date of birth, rate, rank, record... and motivation, and other career related matters to meet [[Page 21261

  1. From Augmentation Media to Meme Media.

    Science.gov (United States)

    Tanaka, Yuzuru

    Computers as meta media are now evolving from augmentation media vehicles to meme media vehicles. While an augmentation media system provides a seamlessly integrated environment of various tools and documents, meme media system provides further functions to edit and distribute tools and documents. Documents and tools on meme media can easily…

  2. Optical recording medium

    International Nuclear Information System (INIS)

    Andriech, A.; Bivol, V.; Tridukh, G.; Tsiuleanu, D.

    2002-01-01

    The invention relates of the micro- and optoelectronics, computer engineering ,in particular, to tjhe optical information media and may be used in hilography. Summary of the invention consists in that the optical image recording medium, containing a dielectric substrates, onto one surface of which there are placed in series a transparent electricity conducting layer, a photo sensitive recording layer of chalcogenic glass and a thin film electrode of aluminium, is provided with an optically transparent protective layer, applied into the thin film electrode. The result of the invention consists in excluding the dependence of chemical processes course into the medium upon environmental conditions

  3. Response of alluvial systems to Late Pleistocene climate changes recorded by environmental magnetism in the Añavieja Basin (Iberian Range, NE Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Oliva-Urcia, B.; Muñoz, A.; Larrasoaña, J.C.; Luzon, A.; Perez, A.; Gonzalez, A.; Jiang, Z.; Liu, Q.; Roman-Berdi, T.

    2016-07-01

    Environmental magnetic proxies were analyzed in a relatively monotonous, ~25.3m thick alluvial sedimentary sequence drilled in the Añavieja Basin (NE Spain). Results from the core AÑ2 suggest that the concentrationdependent magnetic parameters mainly reflect variations in the content of detrital magnetite, sourced in the catchment rocks and soils of the basin, via changes in the dynamics of alluvial fans due to temperature changes in the northern hemisphere during the Late Pleistocene. The correspondence between the magnetic proxies and the temperature variations in the North Atlantic region (NGRIP curve) indicates that higher (lower) concentrations and finer (coarser) magnetite grains coincide with warm (cold) periods. We propose that during cold periods, a sparser vegetation cover favored the incoming of higher energy runoff bearing coarser sediments to the basin that are relatively impoverished in magnetite. In contrast, during warm periods, the wider distribution of the vegetation cover associated with the lower runoff energy lead to finer, magnetite-richer sediment input to the basin. Maghemite, presumably of pedogenic origin, appears to be present also in the studied alluvial sediments. Further studies are necessary to unravel its palaeoclimatic significance. (Author)

  4. Pressure gages for aggressive media

    International Nuclear Information System (INIS)

    Ermolenko, V.L.; Levchuk, N.F.; Nikolaev, V.A.

    1984-01-01

    The device for measuring the pressure in agressive media, designed using the K140UD1B and K140UD8A integrated microelectronic circuits is described. The device sensitivity in conjunction with the membrane zero-indicator constitutes 10 Pa, in case of automated counterpressure control by magnetic valves it is equal to 50 Pa per one device scale mark

  5. Iron-based magnetic molecular imprinted polymers and their application in removal and determination of di-n-pentyl phthalate in aqueous media.

    Science.gov (United States)

    Li, Jing; Zhou, Qingxiang; Yuan, Yongyong; Wu, Yalin

    2017-08-01

    Iron-based magnetic molecular imprinted polymers (Fe@SiO 2 @MIP) were synthesized for highly selective removal and recognition of di- n -pentyl phthalate (DnPP) from water. Well-defined core-shell Fe@SiO 2 nanoparticles (less than 70 nm) were decorated on MIPs reticular layers to endow DnPP-MIPs with magnetic property for the first time. Five other phthalic acid esters including dimethyl phthalate, diethyl phthalate, dipropyl phthalate, di- n -butyl phthalate and di-iso-octyl phthalate were used to investigate the adsorptive selectivity to DnPP. The designed experiments were carried out to explore the adsorption kinetics, isotherms and thermodynamics and the results demonstrated that the adsorption was a spontaneous, exothermal and physical adsorption process. The materials were proved to be excellent adsorbents in removal of DnPP with an adsorption capacity as high as 194.15 mg g -1 in optimal condition. Furthermore, a magnetic solid phase extraction with Fe@SiO 2 @MIP coupled to high-performance liquid chromatography method was successfully developed for the determination of DnPP, and the proposed method achieved a good linear range of 0.5-250 µg l -1 with a correlation coefficient ( R 2 ) of 0.999 and low limit of detection (LOD) of 0.31 µg l -1 . These materials exhibited excellent capacity in removal and highly sensitive identification of DnPP from aqueous environment samples, and opened a valuable direction for developing new adsorbents for the removal and enrichment of important pollutants.

  6. The nonlocal elastomagnetoelectrostatics of disordered micropolar media

    International Nuclear Information System (INIS)

    Kabychenkov, A. F.; Lisiovskii, F. V.

    2016-01-01

    The interactions of electric, magnetic, and elastic subsystems in nonlinear disordered micropolar media that possess a bending–torsion tensor and an nonsymmetric strain tensor have been studied in the framework of phenomenological elastomagnetoelectrostatics. A system of nonlinear equations for determining the ground state of these media has been obtained by the variational method. It is shown that nonuniform external and internal rotations not only create elastic stresses, but also generate additional electric and magnetic fields, while nonuniform elastic stresses and external fields induce internal rotations. The nonlocal character of the micropolar media significantly influences elementary excitations and nonlinear dynamic processes.

  7. Magnetic nanoparticles studied by small angle X-ray scattering

    International Nuclear Information System (INIS)

    Oliveira, Cristiano Luis Pinto; Antonel, Soledad; Negri, Martin

    2011-01-01

    Full text: Magnetic nanoparticles have attracted much attention in the past decades because of their potential applications in high-density magnetic recording, magnetic fluids, data storage, spin-tronics, solar cells, sensors and catalysis. Among the magnetic nanoparticles, cobalt ferrite (CoFe 2 O 4 ) has been widely studied due to high electromagnetic performance, excellent chemical stability, mechanical hardness, and high cubic magnetocrystalline anisotropy. These properties make it a promising candidate for many applications in commercial electronics such as video, audio tapes, high-density digital recording media, and magnetic fluids. Other interesting application is the use of magnetic nanocompounds in the design of magneto elastomers. Magnetoelastomers are dispersions of magnetic particles into an elastomer polymer matrix. These materials are highly promising for applications in the development of sensors and actuators, mainly because of the possibility to optimize the quality parameters of the devices by systematically changing the chemical nature of both the inorganic particles and the organic polymeric matrix, with the consequent modification of the magnetic, electric and elastic properties. Moreover, nanoparticles of cobalt-iron oxides (cobalt ferrite, CoFe 2 O 4 ) appears as very interesting compounds for magnetoelasticity, not only because present magnetic anisotropy, moderate-high magnetization and high coercitivity at room temperature, but also because the possibility to modulate its magnetic properties by chemical synthesis, that is by synthesizing nanoparticles of different sizes having thus not only different magnetic parameters but also different magnetic behavior (superparamagnetism or ferromagnetism). That means that most of the magnetic properties of CoFe 2 O 4 ferrite strongly depend on the size and shape of the nanoparticles, which are closely related to the method of preparation. On the other hand, nickel nanoparticles are very interesting

  8. Magnetic nanoparticles studied by small angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cristiano Luis Pinto [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica. Grupo de Fluidos Complexos; Antonel, Soledad; Negri, Martin [Universidad de Buenos Aires (UBA) (Argentina). Facultad de Ciencias Exactas y Naturales. Dept. de Quimica Inorganica, Analitica y Quimica Fisica

    2011-07-01

    Full text: Magnetic nanoparticles have attracted much attention in the past decades because of their potential applications in high-density magnetic recording, magnetic fluids, data storage, spin-tronics, solar cells, sensors and catalysis. Among the magnetic nanoparticles, cobalt ferrite (CoFe{sub 2}O{sub 4}) has been widely studied due to high electromagnetic performance, excellent chemical stability, mechanical hardness, and high cubic magnetocrystalline anisotropy. These properties make it a promising candidate for many applications in commercial electronics such as video, audio tapes, high-density digital recording media, and magnetic fluids. Other interesting application is the use of magnetic nanocompounds in the design of magneto elastomers. Magnetoelastomers are dispersions of magnetic particles into an elastomer polymer matrix. These materials are highly promising for applications in the development of sensors and actuators, mainly because of the possibility to optimize the quality parameters of the devices by systematically changing the chemical nature of both the inorganic particles and the organic polymeric matrix, with the consequent modification of the magnetic, electric and elastic properties. Moreover, nanoparticles of cobalt-iron oxides (cobalt ferrite, CoFe{sub 2}O{sub 4}) appears as very interesting compounds for magnetoelasticity, not only because present magnetic anisotropy, moderate-high magnetization and high coercitivity at room temperature, but also because the possibility to modulate its magnetic properties by chemical synthesis, that is by synthesizing nanoparticles of different sizes having thus not only different magnetic parameters but also different magnetic behavior (superparamagnetism or ferromagnetism). That means that most of the magnetic properties of CoFe{sub 2}O{sub 4} ferrite strongly depend on the size and shape of the nanoparticles, which are closely related to the method of preparation. On the other hand, nickel

  9. Media Training

    CERN Multimedia

    CERN. Geneva

    2009-01-01

    With the LHC starting up soon, the world's media are again turning their attention to CERN. We're all likely to be called upon to explain what is happening at CERN to media, friends and neighbours. The seminar will be given by BBC television news journalists Liz Pike and Nadia Marchant, and will deal with the kind of questions we're likely to be confronted with through the restart period. The training is open for everybody. Make sure you arrive early enough to get a seat - there are only 200 seats in the Globe. The session will also be webcast: http://webcast.cern.ch/

  10. Magnetically responsive enzyme powders

    Energy Technology Data Exchange (ETDEWEB)

    Pospiskova, Kristyna, E-mail: kristyna.pospiskova@upol.cz [Regional Centre of Advanced Technologies and Materials, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Safarik, Ivo, E-mail: ivosaf@yahoo.com [Regional Centre of Advanced Technologies and Materials, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Nanobiotechnology, Institute of Nanobiology and Structural Biology of GCRC, Na Sadkach 7, 370 05 Ceske Budejovice (Czech Republic)

    2015-04-15

    Powdered enzymes were transformed into their insoluble magnetic derivatives retaining their catalytic activity. Enzyme powders (e.g., trypsin and lipase) were suspended in various liquid media not allowing their solubilization (e.g., saturated ammonium sulfate and highly concentrated polyethylene glycol solutions, ethanol, methanol, 2-propanol) and subsequently cross-linked with glutaraldehyde. Magnetic modification was successfully performed at low temperature in a freezer (−20 °C) using magnetic iron oxides nano- and microparticles prepared by microwave-assisted synthesis from ferrous sulfate. Magnetized cross-linked enzyme powders were stable at least for two months in water suspension without leakage of fixed magnetic particles. Operational stability of magnetically responsive enzymes during eight repeated reaction cycles was generally without loss of enzyme activity. Separation of magnetically modified cross-linked powdered enzymes from reaction mixtures was significantly simplified due to their magnetic properties. - Highlights: • Cross-linked enzyme powders were prepared in various liquid media. • Insoluble enzymes were magnetized using iron oxides particles. • Magnetic iron oxides particles were prepared by microwave-assisted synthesis. • Magnetic modification was performed under low (freezing) temperature. • Cross-linked powdered trypsin and lipase can be used repeatedly for reaction.

  11. Social Media Sites

    Science.gov (United States)

    Media Sites Site Registration Contact Us Search AF.mil: Home > AF Sites > Social Media Sites Social Media Welcome to the Air Force social media directory! The directory is a one-stop shop of official Air Force social media pages across various social media sites. Social media is all about

  12. Reducing loss in lateral charged-particle equilibrium due to air cavities present in x-ray irradiated media by using longitudinal magnetic fields

    International Nuclear Information System (INIS)

    Naqvi, Shahid A.; Li, X. Allen; Ramahi, Shada W.; Chu, James C.; Ye, Sung-Joon

    2001-01-01

    The underdosing of lesions distal to air cavities, such as those found in upper respiratory passages, occurs due to the loss in lateral charged-particle equilibrium (CPE). The degree of underdosing worsens for smaller field sizes, resulting in more frequent recurrence of the cancer treated. Higher photon energies further aggravate the outcome by producing longer second build-up regions beyond the cavity. Besides underdosing, the larger lateral spread of secondary electron fluence in the air cavity produces diffuse dose distributions at the tissue-air interface for shaped or intensity modulated fields. These disequilibrium effects create undesirable deviations from the intended treatment. The clinical concern is further intensified by the failure of traditional treatment planning systems to even account for such defects. In this work, the use of longitudinal magnetic fields on the order of 0.5 T is proposed for alleviating lateral electronic disequilibrium due to the presence of air cavities in the irradiated volume. The magnetic field enforces lateral CPE by restricting the lateral range of electrons in the air cavity. The problem is studied in a simple water-air-water slab geometry using EGS4 Monte Carlo simulations for 6 MV photons. Electronic disequilibrium is evaluated for beams of various sizes, shapes and intensity distributions constructed by linear superposition of the dose distributions for 0.5x0.5 cm 2 beamlets. Comparison is also made with 60 Co irradiation. The results indicate that the lateral confinement of secondary electrons in the air cavity by sub-MRI strength longitudinal fields is effective in reducing deterioration of dose distributions near tissue-air interfaces. This can potentially reduce recurrence rates of cancers such as the larynx carcinoma

  13. Contrast media

    International Nuclear Information System (INIS)

    Decazes, Ph.

    2004-01-01

    The Guerbet firm, which holds 69% of the capital on the contrast media for medical imagery, could sale about 20% of this capital in order to accelerate its development in the United States, one of its next market with the Japan. (O.M.)

  14. Otitis media

    NARCIS (Netherlands)

    Rovers, MM; Schilder, AGM; Zielhuis, GA; Rosenfeld, RM

    2004-01-01

    Otitis media (OM) continues to be one of the most common childhood infections and is a major cause of morbidity in children. The pathogenesis of OM is multifactorial, involving the adaptive and native immune system, Eustachian-tube dysfunction, viral and bacterial load, and genetic and environmental

  15. Social Media

    Science.gov (United States)

    2010-05-01

    Digital Marketing and Ecommerce Professionals. 29 January 2010. 20 May 2010. <http://econsultancy.com/blog/5324-20+-mind-blowing-social- media...Statistics Revisited.” Econsultancy | Community of Digital Marketing and Ecommerce Professionals. 29 Jan. 2010. 20 May 2010. <http://econsultancy.com/blog

  16. Streaming Media

    Science.gov (United States)

    Pulley, John

    2009-01-01

    At a time when the evolutionary pace of new media resembles the real-time mutation of certain microorganisms, the age-old question of how best to connect with constituents can seem impossibly complex--even for an elite institution plugged into the motherboard of Silicon Valley. Identifying the most effective vehicle for reaching a particular…

  17. Gap-mode-assisted light-induced switching of sub-wavelength magnetic domains

    Science.gov (United States)

    Scheunert, G.; McCarron, R.; Kullock, R.; Cohen, S. R.; Rechav, K.; Kaplan-Ashiri, I.; Bitton, O.; Hecht, B.; Oron, D.

    2018-04-01

    Creating sub-micron hotspots for applications such as heat-assisted magnetic recording (HAMR) is a challenging task. The most common approach relies on a surface-plasmon resonator (SPR), whose design dictates the size of the hotspot to always be larger than its critical dimension. Here, we present an approach which circumvents known geometrical restrictions by resorting to electric field confinement via excitation of a gap-mode (GM) between a comparatively large Gold (Au) nano-sphere (radius of 100 nm) and the magnetic medium in a grazing-incidence configuration. Operating a λ=785 nm laser, sub-200 nm hot spots have been generated and successfully used for GM-assisted magnetic switching on commercial CoCrPt perpendicular magnetic recording media at laser powers and pulse durations comparable to SPR-based HAMR. Lumerical electric field modelling confirmed that operating in the near-infrared regime presents a suitable working point where most of the light's energy is deposited in the magnetic layer, rather than in the nano-particle. Further, modelling is used for predicting the limits of our method which, in theory, can yield sub-30 nm hotspots for Au nano-sphere radii of 25-50 nm for efficient heating of FePt recording media with a gap of 5 nm.

  18. Beam-induced magnetic property modifications: Basics, nanostructure fabrication and potential applications

    International Nuclear Information System (INIS)

    Devolder, T.; Bernas, H.; Ravelosona, D.; Chappert, C.; Pizzini, S.; Vogel, J.; Ferre, J.; Jamet, J.-P.; Chen, Y.; Mathet, V.

    2001-01-01

    We have developed an irradiation technique that allows us to tune the magnetic properties of thin films without affecting their roughness. We discuss the mechanisms involved and the applications. He + ion irradiation of Co/Pt multilayers lowers their magnetic anisotropy in a controlled way, reducing the coercive force and then leading to in-plane magnetization. By X-ray reflectometry, we study how irradiation-induced structural modifications correlate with magnetic properties. We also report the L1 0 chemical ordering of FePt by irradiation at 280 deg. C, and the consequent increase of magnetic anisotropy. Planar magnetic patterning at the sub 50 nm scale can be achieved when the irradiation is performed through a mask. New magnetic behaviors result from the fabrication process. They appear to arise from collateral damage. We model these effects in the case of SiO 2 and W masks. The planarity of irradiation-induced patterning and its ability to independently control nanostructure size and coercivity make it very appealing for magnetic recording on nanostructured media. Finally, possible applications to the granular media used in current hard disk drive storage technology are discussed

  19. CoPt and FePt magnetic alloys grown on van der Waals WSe{sub 2}(0001) surfaces and on arrays of SiO{sub 2} spherical particles

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, Denys

    2008-06-06

    Modern magnetic recording is based on usage of hard magnetic alloys as a recording media. In order to increase the areal storage density (number of stored bits per square inch), materials with a high value of magnetic anisotropy are required to stabilize the direction of the magnetization and thus satisfy the criteria of thermal stability. The magnetic alloy currently used for hard disk drive production is a granular CoCrPt:SiO2 alloy with a grain size of approximately 7 nm and an anisotropy constant of about 0.4 MJ/m{sup 3}. However, the predicted limit of the highest achievable areal density of this type of granular media is 500-600 Gbit/in{sup 2}. To satisfy the demand of higher densities, new magnetic alloys have to be introduced. The most promising candidates for future ultra-high density magnetic recording applications are chemically L10 ordered FePt and CoPt alloys with anisotropy constants of about 10 MJ/m{sup 3} and 3 MJ/m{sup 3}, respectively. In order to obtain a high value of uniaxial magnetic anisotropy, the substrate temperature during molecular beam epitaxy or sputtering deposition has to be higher than 500 C. For practical use in industrial applications the ordering temperature of the FePt and CoPt alloys has to be reduced. One of the promising approaches to reduce the ordering temperature is related to the enhancement of the adatom mobility by growing the alloy on the chemically saturated surface. In this regard an attempt to reduce the ordering temperature of the CoPt alloy with equiatomic composition was performed in the scope of present work by growing the CoPt alloy on van der Waals WSe{sub 2}(0001) substrates. Moreover, an increase in data density can be gained using the concept of patterned media, where an information unit (bit) is stored in a single nanostructure. The most attractive way to produce patterned magnetic media for ultra-high density magnetic recording applications is based on self-assembly of the magnetic nanostructures. In this

  20. Artificial Intelligence Controls Tape-Recording Sequence

    Science.gov (United States)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  1. Contribution to the study of nuclear resonance in magnetic media (1963); Contribution a l'etude de la resonance nucleaire dans les milieux magnetique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann-Boutron, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    An attempt is made to interpret the results of nuclear magnetic resonance experiments made by various workers on ferro and ferrimagnetic compounds of the iron group. The problems encountered are the following: effects of the dipolar fields and the hyperfine structure anisotropy; signal intensity; frequency pulling due to the Suhl-Nakamura interaction between nuclear spins ; nuclear relaxation and ferrimagnetic resonance in single domain samples of impure YIG; nuclear relaxation in the Bloch walls of insulators. The results of our calculations are generally in good agreement with experiment. (author) [French] On se propose d'interpreter les resultats d'experiences de resonance magnetique nucleaire fates par divers auteurs sur des composes ferro et ferrimagnetiques du groupe du fer. Les problemes abordes sont les suivants: effets des champs dipolaires et de l'anisotropie de structure hyperfine; intensite des signaux; deplacement de frequence du a l'interaction de Suhl-Nakamura entre spins nucleaires; relaxation nucleaire et resonance ferrimagnetique dans les echantillons monodomaines de grenat de fer et d'yttrium impur; relaxation nucleaire dans les parois de Bloch des isolants. Les resultats des calculs sont generalement en bon accord avec l'experience. (auteur)

  2. Contribution to the study of nuclear resonance in magnetic media (1963); Contribution a l'etude de la resonance nucleaire dans les milieux magnetique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann-Boutron, F. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-06-15

    An attempt is made to interpret the results of nuclear magnetic resonance experiments made by various workers on ferro and ferrimagnetic compounds of the iron group. The problems encountered are the following: effects of the dipolar fields and the hyperfine structure anisotropy; signal intensity; frequency pulling due to the Suhl-Nakamura interaction between nuclear spins ; nuclear relaxation and ferrimagnetic resonance in single domain samples of impure YIG; nuclear relaxation in the Bloch walls of insulators. The results of our calculations are generally in good agreement with experiment. (author) [French] On se propose d'interpreter les resultats d'experiences de resonance magnetique nucleaire fates par divers auteurs sur des composes ferro et ferrimagnetiques du groupe du fer. Les problemes abordes sont les suivants: effets des champs dipolaires et de l'anisotropie de structure hyperfine; intensite des signaux; deplacement de frequence du a l'interaction de Suhl-Nakamura entre spins nucleaires; relaxation nucleaire et resonance ferrimagnetique dans les echantillons monodomaines de grenat de fer et d'yttrium impur; relaxation nucleaire dans les parois de Bloch des isolants. Les resultats des calculs sont generalement en bon accord avec l'experience. (auteur)

  3. [Chronic otitis mediaChronic Otitis Media].

    Science.gov (United States)

    Kohles, N; Schulz, T; Eßer, D

    2015-11-01

    There are 2 different kinds of chronic otitis media: Otitis media chronica mesotympanalis and otitis media chronica epitympanalis (cholesteatoma). The incidence of chronic otitis media as reported in literature differs in a wide range. The incidence rates vary between 0.45 and 46%. Both, otitis media chronica mesotympanalis and cholesteatoma, lead to eardrum perforation due to lengthy and recurring inflammations. Furthermore, chronic otitis media is characterized by frequently recurring otorrhea and conductive hearing loss. Georg Thieme Verlag KG Stuttgart · New York.

  4. On Media Education

    Science.gov (United States)

    Fedorov, Alexander

    2008-01-01

    This monograph analyzes the theory and practice of media education and media literacy. The book also includes the list of Russian media education literature and addresses of websites of the associations for media education.

  5. Otitis media.

    Science.gov (United States)

    Schilder, Anne G M; Chonmaitree, Tasnee; Cripps, Allan W; Rosenfeld, Richard M; Casselbrant, Margaretha L; Haggard, Mark P; Venekamp, Roderick P

    2016-09-08

    Otitis media (OM) or middle ear inflammation is a spectrum of diseases, including acute otitis media (AOM), otitis media with effusion (OME; 'glue ear') and chronic suppurative otitis media (CSOM). OM is among the most common diseases in young children worldwide. Although OM may resolve spontaneously without complications, it can be associated with hearing loss and life-long sequelae. In developing countries, CSOM is a leading cause of hearing loss. OM can be of bacterial or viral origin; during 'colds', viruses can ascend through the Eustachian tube to the middle ear and pave the way for bacterial otopathogens that reside in the nasopharynx. Diagnosis depends on typical signs and symptoms, such as acute ear pain and bulging of the tympanic membrane (eardrum) for AOM and hearing loss for OME; diagnostic modalities include (pneumatic) otoscopy, tympanometry and audiometry. Symptomatic management of ear pain and fever is the mainstay of AOM treatment, reserving antibiotics for children with severe, persistent or recurrent infections. Management of OME largely consists of watchful waiting, with ventilation (tympanostomy) tubes primarily for children with chronic effusions and hearing loss, developmental delays or learning difficulties. The role of hearing aids to alleviate symptoms of hearing loss in the management of OME needs further study. Insertion of ventilation tubes and adenoidectomy are common operations for recurrent AOM to prevent recurrences, but their effectiveness is still debated. Despite reports of a decline in the incidence of OM over the past decade, attributed to the implementation of clinical guidelines that promote accurate diagnosis and judicious use of antibiotics and to pneumococcal conjugate vaccination, OM continues to be a leading cause for medical consultation, antibiotic prescription and surgery in high-income countries.

  6. Media matters.

    Science.gov (United States)

    Martinez, L M

    1995-01-01

    The impact of the mass media on woman's status was addressed at two 1995 conferences: the Fourth World Conference on Women, held in Beijing, China, and the Congress of the World Association for Christian Communication, held in Puebla, Mexico. The globalization process facilitated by the mass media has served to increase the power of patriarchy, with no advantages to the cause of women's rights. Coverage of popular movements has been suppressed out of deference to male-controlled governments. Coverage of the Beijing Conference highlighted celebrities and personal stories, to the exclusion of the economic and political issues under debate. Television has commodified women, reinforcing their oppression. On the other hand, the alternative media, which tend to be decentralized, democratic, low-cost, and low in technology, are presenting women as subjects rather than objects and deconstructing gender stereotypes. Of concern, however, is the tendency of computer technology to widen the gap between social classes and developed and developing countries. Women must use information networks to disseminate information on women's rights and strengthen the links between women throughout the world.

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography ( ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or thyroid problems. Any of these conditions may influence the decision on whether contrast material will be ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic ...

  13. Teaching Information Skills: Recording Information.

    Science.gov (United States)

    Pappas, Marjorie L.

    2002-01-01

    Discusses how to teach students in primary and intermediate grades to record and organize information. Highlights include developing a research question; collaborative planning between teachers and library media specialists; consistency of data entry; and an example of a unit on animal migration based on an appropriate Web site. (LRW)

  14. Media Education Initiatives by Media Organizations: The Uses of Media Literacy in Hong Kong Media

    Science.gov (United States)

    Chu, Donna; Lee, Alice Y. L.

    2014-01-01

    As more media organizations have engaged in media education, this paper investigates the goals and practices of these activities. This article coins media education initiatives by media organizations with the term "media-organization media literac"y (MOML). Four MOML projects in Hong Kong were selected for examination. Built on critical…

  15. Magnetic Signature Analysis & Validation System

    National Research Council Canada - National Science Library

    Vliet, Scott

    2001-01-01

    The Magnetic Signature Analysis and Validation (MAGSAV) System is a mobile platform that is used to measure, record, and analyze the perturbations to the earth's ambient magnetic field caused by object such as armored vehicles...

  16. Bedroom media: One risk factor for development.

    Science.gov (United States)

    Gentile, Douglas A; Berch, Olivia N; Choo, Hyekyung; Khoo, Angeline; Walsh, David A

    2017-12-01

    Mass media have numerous effects on children, ranging from influencing school performance to increased or reduced aggression. What we do not know, however, is how media availability in the bedroom moderates these effects. Although several researchers have suggested that bedroom media may influence outcomes by displacing other activities (the displacement hypothesis) or by changing the content of media consumed (the content hypothesis), these have rarely been tested directly. This study tested both hypotheses using several outcomes that are associated with bedroom media and some of the underlying mediating mechanisms. The hypotheses were tested using 3 longitudinal samples of varying methods, age, duration, and country. The results indicate that children who have bedroom media are likely to watch larger amounts of screen time which displaced important activities, such as reading and sleeping, which mediated later negative outcomes such as poor school performance. Bedroom media also influence risk for obesity and video game addiction. Children with bedroom media are also likely to be exposed to more media violence. The violent content increased normative beliefs about aggression, which increased physical aggression, providing support for the content hypothesis. This study demonstrates that media can have effects not just from what they show, but also because of what children are not exposed to. Bedroom media are therefore a robust risk factor for several aspects of child development. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. Wave propagation in electromagnetic media

    CERN Document Server

    Davis, Julian L

    1990-01-01

    This is the second work of a set of two volumes on the phenomena of wave propagation in nonreacting and reacting media. The first, entitled Wave Propagation in Solids and Fluids (published by Springer-Verlag in 1988), deals with wave phenomena in nonreacting media (solids and fluids). This book is concerned with wave propagation in reacting media-specifically, in electro­ magnetic materials. Since these volumes were designed to be relatively self­ contained, we have taken the liberty of adapting some of the pertinent material, especially in the theory of hyperbolic partial differential equations (concerned with electromagnetic wave propagation), variational methods, and Hamilton-Jacobi theory, to the phenomena of electromagnetic waves. The purpose of this volume is similar to that of the first, except that here we are dealing with electromagnetic waves. We attempt to present a clear and systematic account of the mathematical methods of wave phenomena in electromagnetic materials that will be readily accessi...

  18. 75 FR 26201 - Privacy Act of 1974; System of Records

    Science.gov (United States)

    2010-05-11

    ... National Defense Intelligence College. Categories of records in the system: Name, date of birth and Social... States Commission on Higher Education Association Characteristics of Excellence in Higher Education... system: Storage: Electronic storage media. Retrievability: By last name. Safeguards: Records are...

  19. 76 FR 76956 - Privacy Act of 1974; System of Records

    Science.gov (United States)

    2011-12-09

    ... manager. Record source categories: Individual, social workers, rehabilitation counselors, and/or health... mental impairments and applicants for employment with Washington Headquarters Services/Human Resources... of records in the system: Storage: Paper file folders and electronic storage media. Retrievability...

  20. Media Matter

    Directory of Open Access Journals (Sweden)

    Holger Pötzsch

    2017-02-01

    Full Text Available The present contribution maps materialist advances in media studies. Based on the assumption that matter and materiality constitute significant aspects of communication processes and practices, I introduce four fields of inquiry - technology, political economy, ecology, and the body - and argue that these perspectives enable a more comprehensive understanding of the implications of contemporary technologically afforded forms of interaction. The article shows how each perspective can balance apologetic and apocalyptic approaches to the impact of in particular digital technologies, before it demonstrates the applicability of an integrated framework with reference to the techno-politics of NSA surveillance and the counter-practices of WikiLeaks.

  1. TUTORIAL: Focused-ion-beam-based rapid prototyping of nanoscale magnetic devices

    Science.gov (United States)

    Khizroev, S.; Litvinov, D.

    2004-03-01

    In this tutorial, focused-ion-beam (FIB)-based fabrication is considered from a very unconventional angle. FIB is considered not as a fabrication tool that can be used for mass production of electronic devices, similar to optical and E-beam—based lithography, but rather as a powerful tool to rapidly fabricate individual nanoscale magnetic devices for prototyping future electronic applications. Among the effects of FIB-based fabrication of magnetic devices, the influence of Ga+-ion implantation on magnetic properties is presented. With help of magnetic force microscopy (MFM), it is shown that there is a critical doze of ions that a magnetic material can be exposed to without experiencing a change in the magnetic properties. Exploiting FIB from such an unconventional perspective is especially favourable today when the future of so many novel technologies depends on the ability to rapidly fabricate prototype nanoscale magnetic devices. As one of the most illustrative examples, the multi-billion-dollar data storage industry is analysed as the technology field that strongly benefited from implementing FIB in the above-described role. The essential role of FIB in the most recent trend of the industry towards perpendicular magnetic recording is presented. Moreover, other emerging and fast-growing technologies are considered as examples of nanoscale technologies whose future could strongly depend on the implementation of FIB in the role of a nanoscale fabrication tool for rapid prototyping. Among the other described technologies are 'ballistic' magnetoresistance, patterned magnetic media, magnetoresistive RAM (MRAM), and magnetic force microscopy.

  2. Phenological Records

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Phenology is the scientific study of periodic biological phenomena, such as flowering, breeding, and migration, in relation to climatic conditions. The few records...

  3. Media education and media influence on youth

    OpenAIRE

    LILÁK, Karel

    2011-01-01

    Bachelor´s work is focused on the questions of the medial education and the medias themselves. This work also investigate with the influence of the action of medias to the students of apprenticeship. The first part of the theoretical work has generally explains what is media education, what is its significance for society and for the benefit of education in school. They are given functions, types and objectives of media education and communications capabilities via the media. The second part ...

  4. Role of Tb–Mn substitution on the magnetic properties of Y-type hexaferrites

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Irshad, E-mail: irshadalibzu@gmail.com [Department of Physics, Bahauddin Zakariya University, Multan 60800 (Pakistan); Islam, M.U. [Department of Physics, Bahauddin Zakariya University, Multan 60800 (Pakistan); Ashiq, Muhammad Naeem, E-mail: naeemashiqqau@yahoo.com [Institute of Chemical Sciences, Bahauddin Zakariya University, Multan 60800 (Pakistan); Asif Iqbal, M. [National University of Sciences and Technology, EME College, Islamabad (Pakistan); Karamat, Nazia [Institute of Chemical Sciences, Bahauddin Zakariya University, Multan 60800 (Pakistan); Awan, M.S. [Center for Micro and Nano Devices, Department of Physics, COMSAT Institute of Information Technology, Islamabad (Pakistan); Naseem, Shahzad [Centre for Solid State Physics, University of the Punjab, Lahore 54560 (Pakistan)

    2014-06-25

    Graphical abstract: In-plane MH-loop of Tb–Mn substituted Co{sub 2}Sr{sub 2}Fe{sub 12}O{sub 22}. - Highlights: • The magnetic properties changes with increasing substitution level. • The shape of grains is plate like useful for microwave devices. • The samples can be used in perpendicular recording media (PRM) due to their high value of coercivity. - Abstract: A series of (Tb–Mn) doped Sr{sub 2}Co{sub (2−x)}Mn{sub x}Tb{sub y}Fe{sub (12−y)}O{sub 22} (x = 0.0–1, Y = 0.0–0.1) Y-type hexaferrite were synthesized by the microemulsion method. The effect of doping of manganese at the tetrahedral site, and terbium at octahedral site, has been studied. It was observed that changes in magnetic properties such as saturation magnetization, coercivity, remanence and magnetic moment due to the cationic stoichiometry and their occupancy in the specific sites. The energy-dispersive X-ray fluorescence analysis was used to confirm the concentration of the elements. Scanning electron micrograph of the samples showed that grains are of plate like shape which is quite encouraging for their use in microwave devices and in perpendicular recording media (PRM) due to their high value of coercivity, 3200 Oe comparable to M-type and W-type hexaferrites hard magnetic materials.

  5. Managing Media: Segmenting Media Through Consumer Expectancies

    Directory of Open Access Journals (Sweden)

    Matt Eastin

    2014-04-01

    Full Text Available It has long been understood that consumers are motivated to media differently. However, given the lack of comparative model analysis, this assumption is without empirical validation, and thus, the orientation of segmentation from a media management perspective is without motivational grounds. Thus, evolving the literature on media consumption, the current study develops and compares models of media segmentation within the context of use. From this study, six models of media expectancies were constructed so that motivational differences between media (i.e., local and national newspapers, network and cable television, radio, and Internet could be observed. Utilizing higher order statistical analyses the data indicates differences across a model comparison approach for media motivations. Furthermore, these differences vary across numerous demographic factors. Results afford theoretical advancement within the literature of consumer media consumption as well as provide media planners’ insight into consumer choices.

  6. Geographic Media Literacy

    Science.gov (United States)

    Lukinbeal, Chris

    2014-01-01

    While the use of media permeates geographic research and pedagogic practice, the underlying literacies that link geography and media remain uncharted. This article argues that geographic media literacy incorporates visual literacy, information technology literacy, information literacy, and media literacy. Geographic media literacy is the ability…

  7. Adolescents and media literacy.

    Science.gov (United States)

    McCannon, Robert

    2005-06-01

    In the face of media industry consolidation, fewer people control media content which makes it harder for parents and citizens to know the research about media-related issues, such as video game violence, nutrition, and sexual risk-taking. Media literacy offers a popular and potentially successful way to counter the misinformation that is spread by Big Media public relations.

  8. Safety in online media – freedom of the media; safety of media actors and media education

    OpenAIRE

    Moeller, Ch

    2013-01-01

    In this paper, prepared for the international conference ‘Mass Media – Society – Education: Media Safety Problems’ at the Chelyabinsk State University’s Department for Journalism and Media Education from September 30 – October 3, 2013, I would like to address three dimensions of media safety and security in online media.

  9. SOCIAL MEDIA SECURITY

    Science.gov (United States)

    RESPONSIBILITY CENTCOM COALITION MEDIA SOCIAL MEDIA NEWS ARTICLES PRESS RELEASES IMAGERY VIDEOS TRANSCRIPTS VISITORS AND PERSONNEL FAMILY CENTER FAMILY READINESS CENTCOM WEBMAIL SOCIAL MEDIA SECURITY ACCOUNTABILITY HomeVISITORS AND PERSONNELSOCIAL MEDIA SECURITY FAQ on Security for Social Media Due to the widespread use of

  10. Measuring News Media Literacy

    Science.gov (United States)

    Maksl, Adam; Ashley, Seth; Craft, Stephanie

    2015-01-01

    News media literacy refers to the knowledge and motivations needed to identify and engage with journalism. This study measured levels of news media literacy among 500 teenagers using a new scale measure based on Potter's model of media literacy and adapted to news media specifically. The adapted model posits that news media literate individuals…

  11. Morphological Variations in Conidia of Arthrobotrys oligospora on Different Media

    OpenAIRE

    Singh, R. K.; Kumar, Niranjan; Singh, K. P.

    2005-01-01

    Most commonly occurring predacious fungus Arthrobotrys oligospora showed great variation in size and shape of conidia on some media. The formation of larger conidia was recorded on beef extract and nutrient agar media. The length of conidia in Richard's YPSS, Sabouraud's, PDA and corn meal agar media was of medium size while smaller conidia were produced on Czapek's, Jensen's, Martin's medium. Maximum width of conidia was recorded on YPSS medium followed by Sabouraud's medium. The average siz...

  12. 76 FR 10010 - Privacy Act of 1974; System of Records

    Science.gov (United States)

    2011-02-23

    ....'' * * * * * Storage: Delete entry and replace with ``Maintained on electronic storage media and/or in file binders... individual for consideration of continued service in the Air Force. Paper records are destroyed by tearing... records in the system: Storage: Maintained on electronic storage media and/or in file binders/ cabinets...

  13. 76 FR 75421 - Managing Government Records

    Science.gov (United States)

    2011-12-01

    ... redundant efforts, to save money, and to share knowledge within and across their organizations. In these... current plans for improving or maintaining its records management program, particularly with respect to managing electronic records, including email and social media, deploying cloud-based services or storage...

  14. Multiple Generations on Video Tape Recorders.

    Science.gov (United States)

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  15. Media Literacy in Times of Media Divides

    Directory of Open Access Journals (Sweden)

    Kaja Žuran

    2013-12-01

    Full Text Available We live in a post-modern society, an information society, a society based around knowledge and participation, and above all in a media society. In a media culture where media holds a dominant position, we cannot overlook the emerging idea of a ‘media divide’ within the frame of media education, media literate individuals and the expansion of the traditional concept of media literacy. Firstly, we are in an era of technological revolution, and it is time to consider the meaning and function of media and how we experience it in our everyday life. Secondly, as a society we are subject to intense media invasion and we all need to learn how to use it to our benefit and apply a critical and autonomous perspective towards selecting media content. Otherwise the media divide between the media literate and illiterate will widen; but is there even a chance to overcome the supposed divide between those who are formally media educated and those who are not?

  16. Otitis media with effusion

    Science.gov (United States)

    OME; Secretory otitis media; Serous otitis media; Silent otitis media; Silent ear infection; Glue ear ... from the tube and is swallowed. OME and ear infections are connected in two ways: After most ear ...

  17. 75 FR 52513 - Privacy Act of 1974; System of Records

    Science.gov (United States)

    2010-08-26

    ... practices data, and employee health hazard educational data. Records include the name, Social Security... system of records notice. Note 2: Personal identity, diagnosis, prognosis of any patient maintained in... Records in the System: Storage: Paper records and electronic storage media. Retrievability: By individual...

  18. 75 FR 42719 - Privacy Act of 1974; System of Records

    Science.gov (United States)

    2010-07-22

    ... characteristics (such as name, last four digits of Social Security Number (SSN), grade, Unit Identification Code...) organization. CATEGORIES OF RECORDS IN THE SYSTEM: Name, last four digits of Social Security Number (SSN), duty... RECORDS IN THE SYSTEM: STORAGE: Records are stored on electronic storage media. RETRIEVABILITY: Records...

  19. Directed self-assembly of block copolymers for use in bit patterned media fabrication

    International Nuclear Information System (INIS)

    Griffiths, Rhys Alun; Vijayaraghavan, Aravind; Thomson, Thomas; Williams, Aled; Oakland, Chloe; Roberts, Jonathan

    2013-01-01

    Reduction of the bit size in conventional magnetic recording media is becoming increasingly difficult due to the superparamagnetic limit. Bit patterned media (BPM) has been proposed as a replacement technology as it will enable hard disk areal densities to increase past 1 Tb in −2 . Block copolymer directed self-assembly (BCP DSA) is the leading candidate for forming BPM due to its ability to create uniform patterns over macroscopic areas. Here we review the latest research into two different BCP DSA techniques: graphoepitaxy and chemoepitaxy (or chemical prepatterning). In addition to assessing their potential for forming high density bit patterns, we also review current approaches using these techniques for forming servo patterns, which are required for hard disk drive (HDD) operation. Finally, we review the current state of UV nanoimprint lithography, which is the favoured technique for enabling mass production of BPM HDDs. (topical review)

  20. RECORDS REACHING RECORDING DATA TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    G. W. L. Gresik

    2013-07-01

    Full Text Available The goal of RECORDS (Reaching Recording Data Technologies is the digital capturing of buildings and cultural heritage objects in hard-to-reach areas and the combination of data. It is achieved by using a modified crane from film industry, which is able to carry different measuring systems. The low-vibration measurement should be guaranteed by a gyroscopic controlled advice that has been , developed for the project. The data were achieved by using digital photography, UV-fluorescence photography, infrared reflectography, infrared thermography and shearography. Also a terrestrial 3D laser scanner and a light stripe topography scanner have been used The combination of the recorded data should ensure a complementary analysis of monuments and buildings.

  1. Records Reaching Recording Data Technologies

    Science.gov (United States)

    Gresik, G. W. L.; Siebe, S.; Drewello, R.

    2013-07-01

    The goal of RECORDS (Reaching Recording Data Technologies) is the digital capturing of buildings and cultural heritage objects in hard-to-reach areas and the combination of data. It is achieved by using a modified crane from film industry, which is able to carry different measuring systems. The low-vibration measurement should be guaranteed by a gyroscopic controlled advice that has been , developed for the project. The data were achieved by using digital photography, UV-fluorescence photography, infrared reflectography, infrared thermography and shearography. Also a terrestrial 3D laser scanner and a light stripe topography scanner have been used The combination of the recorded data should ensure a complementary analysis of monuments and buildings.

  2. Intermediality and media change

    OpenAIRE

    2012-01-01

    This book is about intermediality as an approach to analysing and understanding media change. Intermediality and Media Change is critical of technological determinism that characterises 'new media discourse' about the ongoing digitalization, framed as a revolution and creating sharp contrasts between old and new media. Intermediality instead emphasises paying attention to continuities between media of all types and privileges a comparative perspective on technological changes in media over ti...

  3. Media Pembelajaran Global Warming

    OpenAIRE

    Tham, Fikri Jufri; Liliana, Liliana; Purba, Kristo Radion

    2016-01-01

    Computer based learning media is one of the media has an important role in learning. Learning media will be attractive when packaged through interactive media , such as interactive media created in paper manufacture " instructional media global warming" . The advantage gained is that it can increase knowledge, generally educate people to be more concerned about the environment , and also can be a means of entertainment. This application is focused to learn about global warming and packaged in...

  4. Social media management and media environment

    Directory of Open Access Journals (Sweden)

    Šiđanin Iva

    2012-01-01

    Full Text Available The paper deals with the system of services that social media management can offer to a variety of users. As social media systems are emerging, social media management can strengthen teams in social media and help to manage numerous social channels and distribution of social information from one place. Social media management is a system of procedures that are used to manage the flow of information in the environment of social media. This involves connecting with social media like Facebook, Twitter, LinkedIn, Plaxo, Ecademy, YouTube and many others, then the aggregation and management of social data. Social media management services are analysed through various fields, such as managing multiple social media profiles, mail scheduling and filtering, reporting and analytics. Social media management enables managing personal business through social media, which contributes to a significant reduction in expenditures. The paper also discusses the importance of social media management in marketing activities and various forms of social promotion, which allow companies to easily reach their customers.

  5. Electrodynamics of Magnetoactive Media

    International Nuclear Information System (INIS)

    Browning, P K

    2004-01-01

    'Electrodynamics of Magnetoactive Media' is an unusual book in that it cuts across conventional physics discipline boundaries. The unifying theme allowing this is, quite simply, the physics of magnetic fields in various media. I believe the authors are correct in stating that the book is unique in specifically covering electrodynamic phenomena associated with magnetic fields, though of course some of the more elementary aspects are covered in the classical textbooks on electromagnetism, which are duly acknowledged. This interdisciplinarity makes the book very interesting to people with a range of backgrounds. For example, as a plasma physicist, I was familiar with most of the material on plasmas, but liquid crystals and superconductors were entirely new territory for me. These chapters were indeed both accessible and interesting, and it was surprising for me to see how much commonality there is in the physics of these various media. The first part of the book covers some fundamentals of electrodynamics and magnetostatics, and of electromagnetic waves. Most of this material is covered in textbooks on electromagnetism, and some of it is very basic (for example, LRC circuit theory, surely covered in most first year physics courses, is included) but it is perhaps a useful prelude for what is to come. The generic topic of charged particle motion in electromagnetic fields is well covered. Three main magnetoactive media are then discussed: plasmas (focusing on waves), liquid crystals and superconductors. It is all too easy to criticise a book on the grounds of omitted material, but I do feel that a chapter on magnetostatics in plasmas would have been very helpful, covering force-free fields and so on. Some interesting analogies could then have been exploited. For example, I was intrigued to discover an equation for magnetic fields in superconductors (equation (9.36)) which, apart from a change of sign, is identical to the Helmholtz equation used to model linear force

  6. FOTOGRAFI UNTUK MEDIA MASSA

    Directory of Open Access Journals (Sweden)

    Andry Prasetyo

    2016-01-01

    Full Text Available The benefits of photography as a tool for an effective and reliable communicating, are summarized in Photo journalistic . In one side, photography has the feel of reality in detail the reliable, furthermore, photography is also a more rapidly digested, knew and understood. So the response and reaction will be given to the information that there will be more quickly and precisely. Moreover with the invention of digital technology will shorten the process of delivering information to better results and faster. Through a combination of drawings and manuscripts, photographs contained in a newspaper or magazine will give us information as is appropriate. Because the image is recorded based on trust-owned, which is something that is absolutely necessar y to inform the sustainability of human life on this earth. In addition, not only, the works of photo-journalistic produced have the factual, reality and detail that is strong, but also contains the values of the beauty of high, given the work that was created by a photojournalist eye will be seen by millions of human beings throughout the world through the mass media both print and electronically. Keywords: Photography, Mass Media, Script.

  7. Magnetism in the nineties

    International Nuclear Information System (INIS)

    Freeman, A.J.; Gschneider, K.A. Jr

    1991-01-01

    This special volume aims at providing a historical perspective of the developments that have taken place since the first volume of the Journal of Magnetism and Magnetic Materials, that appeared in late 1975, to identify the most important issues and to provide a perspective for developments anticipated in the 1990's. The papers contained in this book cover many of the scientifically exciting and technologically important aspects of magnetism. They deal with research on various materials including amorphous, permanent and semiconducting magnets, magnetic and magneto-optic recording materials, strongly correlated electron systems and high Tc-superconductors. Several important experimental methods for measuring magnetic behaviour are covered, but the book also contains in-depth theoretical research of fundamental problems in magnetism

  8. Magnetic properties and configuration of Fe{sub 50}Pt{sub 50*x}Rh{sub x} films

    Energy Technology Data Exchange (ETDEWEB)

    Fenske, Jochen; Lott, Dieter; Schreyer, Andreas [Helmholt-Zentrum, Geesthacht (Germany); Schmidt, Wolfgang; Schmalzl, Karin [IFF Forschungszentrum, Juelich (Germany); JCNS at ILL (France); Mankey, Gary J. [MINT Center, University of Alabama (United States); Klose, Frank [Ansto, Bragg Institute (Australia); Tartakowskaya, Helena [Institute for Magnetism, National Accademy of Scinece (Ukraine)

    2011-07-01

    Ordered FePt alloys with L1{sub 0} structure are known as materials with FM order and a high magnetic moment of Fe providing a large magnetization. The large atomic number of Pt on the other hand results in a high magnetic anisotropy. If grown in thin films, the high anisotropy often results in perpendicular magnetization which is the preferred orientation for current magnetic recording media. One way to control the magnetic properties in these materials is through the introduction of a third element into the crystal matrix e.g. Rh. When Rh is added to replace Pt in the equiatomic alloy, new magnetic phases emerge. Here we present neutron diffraction studies on the magnetic properties of different 200nm thick Fe{sub 50}Pt{sub 50*x}Rh{sub x} films in dependence of the temperature and external magnetic fields. Additional resonant x-ray measurements on the Fe and Pt absorption edges provide additional information about the magnetic moments on these sites.

  9. Recent recordings

    CERN Multimedia

    Steven Goldfarb

    The University of Michigan ATLAS Collaboratory Project is happy to announce the publication of a number of recent web lectures, including the full Plenary Session from the ATLAS Overview Week, held at CERN in October. Archives from that event are located here and directly on the Indico agenda. Click on the pictures below to access more information. Latest NewsAs announced in the Collaborative Tool Workshop, held on Tuesday of the Overview Week, future events in the Michigan Archives will be available for viewing with a Flash Player plug-in (right image above), as well as the usual Real Player plug-in. This additional option, made possible by our usage of the Lecture Object and standard formats for storing all media and metadata, allows the viewer to choose her/his preferred environment. As always, viewing of the lectures is supported on all major platforms and browsers and there is also the option to download lectures for remote viewing with limited or no network bandwidth.ATLAS 2007 ArchivesAdditional...

  10. Magnetic mesoporous material for the sequestration of algae

    Science.gov (United States)

    Trewyn, Brian G.; Kandel, Kapil; Slowing, Igor Ivan; Lee, Show-Ling

    2014-09-09

    The present invention provides a magnetic mesoporous nanoparticle that includes a mesoporous silicate nanoparticle and iron oxide. The present invention also provides a method of using magnetic mesoporous nanoparticles to sequester microorganisms from a media.

  11. Vinyl Record

    DEFF Research Database (Denmark)

    Bartmanski, Dominik; Woodward, Ian

    2018-01-01

    . This relational process means that both the material affordances and entanglements of vinyl allow us to feel, handle, experience, project, and share its iconicity. The materially mediated meanings of vinyl enabled it to retain currency in independent and collector’s markets and thus resist the planned......In this paper, we use the case of the vinyl record to show that iconic objects become meaningful via a dual process. First, they offer immersive engagements which structure user interpretations through various material experiences of handling, use, and extension. Second, they always work via...

  12. Design and Micromagnetic Simulation of Fe/L10-FePt/Fe Trilayer for Exchange Coupled Composite Bit Patterned Media at Ultrahigh Areal Density

    Directory of Open Access Journals (Sweden)

    Warunee Tipcharoen

    2015-01-01

    Full Text Available Exchange coupled composite bit patterned media (ECC-BPM are one candidate to solve the trilemma issues, overcome superparamagnetic limitations, and obtain ultrahigh areal density. In this work, the ECC continuous media and ECC-BPM of Fe/L10-FePt/Fe trilayer schemes are proposed and investigated based on the Landau-Lifshitz-Gilbert equation. The switching field, Hsw, of the hard phase in the proposed continuous ECC trilayer media structure is reduced below the maximum write head field at interlayer exchange coupling between hard and soft phases, Aex, higher than 20 pJ/m and its value is lower than that for continuous L10-FePt single layer media and L10-FePt/Fe bilayer. Furthermore, the Hsw of the proposed ECC-BPM is lower than the maximum write head field with exchange coupling coefficient between neighboring dots of 5 pJ/m and Aex over 10 pJ/m. Therefore, the proposed ECC-BPM trilayer has the highest potential and is suitable for ultrahigh areal density magnetic recording technology at ultrahigh areal density. The results of this work may be gainful idea for nanopatterning in magnetic media nanotechnology.

  13. Students’ Media Preferences in Online Learning

    Directory of Open Access Journals (Sweden)

    Michiko KOBAYASHI

    2017-07-01

    Full Text Available This study examined students’ preferred media in online learning and its relationship with learner characteristics and online technology self-efficacy. One hundred six college students in a mid-size U.S. university responded to a survey. The frequency analysis showed that students did not necessarily favor rich media over lean media in online learning. They preferred recorded online slide presentations with audio to Internet-based live video lectures in two-way video and audio interactions. Online discussion boards and chat groups were less favored than other types of media. As expected, online technology self-efficacy was correlated with a type of media requiring a relatively higher level of technology skills. The paper presents the results and discusses their implications of the study.

  14. Media Literacy Bibliography.

    Science.gov (United States)

    Duncan, Barry

    1989-01-01

    Provides an up-to-date bibliography of resources available for teaching media literacy. Groups resources into the areas of media education methodology, mass media texts, general background, television, film, the news and medium of print, advertising, gender and the media, popular culture, popular music and rock video, periodicals, and…

  15. Record Club

    CERN Multimedia

    Record Club

    2011-01-01

    http://cern.ch/Record.Club November  Selections Just in time for the holiday season, we have added a number of new CDs and DVDs into the Club. You will find the full lists at http://cern.ch/record.club; select the "Discs of the Month" button on the left side on the left panel of the web page and then Nov 2011. New films include the all 5 episodes of Fast and Furious, many of the most famous films starring Jean-Paul Belmondo and those of Louis de Funes and some more recent films such as The Lincoln Lawyer and, according to some critics, Woody Allen’s best film for years – Midnight in Paris. For the younger generation there is Cars 2 and Kung Fu Panda 2. New CDs include the latest releases by Adele, Coldplay and the Red Hot Chili Peppers. We have also added the new Duets II CD featuring Tony Bennett singing with some of today’s pop stars including Lady Gaga, Amy Winehouse and Willy Nelson. The Club is now open every Monday, Wednesday and Friday ...

  16. Record Club

    CERN Multimedia

    Record Club

    2011-01-01

    http://cern.ch/Record.Club June Selections We have put a significant number of new CDs and DVDs into the Club You will find the full lists at http://cern.ch/record.club and select the «Discs of the Month» button on the left side on the left panel of the web page and then June 2011. New films include the latest Action, Suspense and Science Fiction film hits, general drama movies including the Oscar-winning The King’s Speech, comedies including both chapter of Bridget Jones’s Diary, seven films for children and a musical. Other highlights include the latest Harry Potter release and some movies from the past you may have missed including the first in the Terminator series. New CDs include the latest releases by Michel Sardou, Mylene Farmer, Jennifer Lopez, Zucchero and Britney Spears. There is also a hits collection from NRJ. Don’t forget that the Club is now open every Monday, Wednesday and Friday lunchtimes from 12h30 to 13h00 in Restaurant 2, Building 504. (C...

  17. Record club

    CERN Document Server

    Record club

    2010-01-01

      Bonjour a tous, Voici les 24 nouveaux DVD de Juillet disponibles depuis quelques jours, sans oublier les 5 CD Pop musique. Découvrez la saga du terroriste Carlos, la vie de Gainsbourg et les aventures de Lucky Luke; angoissez avec Paranormal Activity et évadez vous sur Pandora dans la peau d’Avatar. Toutes les nouveautés sont à découvrir directement au club. Pour en connaître la liste complète ainsi que le reste de la collection du Record Club, nous vous invitons sur notre site web: http://cern.ch/crc. Toutes les dernières nouveautés sont dans la rubrique « Discs of the Month ». Rappel : le club est ouvert les Lundis, Mercredis, Vendredis de 12h30 à 13h00 au restaurant n°2, bâtiment 504. A bientôt chers Record Clubbers.  

  18. Record Club

    CERN Multimedia

    Record Club

    2011-01-01

    http://cern.ch/Record.Club Nouveautés été 2011 Le club de location de CDs et de DVDs vient d’ajouter un grand nombre de disques pour l’été 2011. Parmi eux, Le Discours d’un Roi, oscar 2011 du meilleur film et Harry Potter les reliques de la mort (1re partie). Ce n’est pas moins de 48 DVDs et 10 CDs nouveaux qui vous sont proposés à la location. Il y en a pour tous les genres. Alors n’hésitez pas à consulter notre site http://cern.ch/record.club, voir Disc Catalogue, Discs of the month pour avoir la liste complète. Le club est ouvert tous les Lundi, Mercredi, Vendredi de 12h30 à 13h dans le bâtiment du restaurent N°2 (Cf. URL: http://www.cern.ch/map/building?bno=504) A très bientôt.  

  19. Kinetic Monte Carlo simulations of the effect of the exchange control layer thickness in CoPtCrB/CoPtCrSiO granular media

    Science.gov (United States)

    Almudallal, Ahmad M.; Mercer, J. I.; Whitehead, J. P.; Plumer, M. L.; van Ek, J.

    2018-05-01

    A hybrid Landau Lifshitz Gilbert/kinetic Monte Carlo algorithm is used to simulate experimental magnetic hysteresis loops for dual layer exchange coupled composite media. The calculation of the rate coefficients and difficulties arising from low energy barriers, a fundamental problem of the kinetic Monte Carlo method, are discussed and the methodology used to treat them in the present work is described. The results from simulations are compared with experimental vibrating sample magnetometer measurements on dual layer CoPtCrB/CoPtCrSiO media and a quantitative relationship between the thickness of the exchange control layer separating the layers and the effective exchange constant between the layers is obtained. Estimates of the energy barriers separating magnetically reversed states of the individual grains in zero applied field as well as the saturation field at sweep rates relevant to the bit write speeds in magnetic recording are also presented. The significance of this comparison between simulations and experiment and the estimates of the material parameters obtained from it are discussed in relation to optimizing the performance of magnetic storage media.

  20. Understanding Social Media Logic

    OpenAIRE

    José van Dijck; Thomas Poell

    2013-01-01

    Over the past decade, social media platforms have penetrated deeply into the mech­anics of everyday life, affecting people's informal interactions, as well as institutional structures and professional routines. Far from being neutral platforms for everyone, social media have changed the conditions and rules of social interaction. In this article, we examine the intricate dynamic between social media platforms, mass media, users, and social institutions by calling attention to social media log...