  1. Macular thickness and macular volume measurements using spectral domain optical coherence tomography in normal Nepalese eyes

    Directory of Open Access Journals (Sweden)

    Pokharel A

    2016-03-01

    Full Text Available Amrit Pokharel,1 Gauri Shankar Shrestha,2 Jyoti Baba Shrestha2 1Department of Ophthalmology, Kathmandu Medical College Teaching Hospital, 2B P Koirala Lions Centre for Ophthalmic Studies, Institute of Medicine, Kathmandu, Nepal Purpose: To record the normative values for macular thickness and macular volume in normal Nepalese eyes. Methods: In all, 126 eyes of 63 emmetropic subjects (mean age: 21.17±6.76 years; range: 10–37 years were assessed for macular thickness and macular volume, using spectral domain-optical coherence tomography over 6×6 mm2 in the posterior pole. A fast macular thickness protocol was employed. Statistics such as the mean, median, standard deviation, percentiles, and range were used, while a P-value was set at 0.05 to test significance. Results: Average macular thickness and total macular volume were larger in males compared to females. With each year of increasing age, these variables decreased by 0.556 µm and 0.0156 mm3 for average macular thickness and total macular volume, respectively. The macular thickness was greatest in the inner superior section and lowest at the center of the fovea. The volume was greatest in the outer nasal section and thinnest in the fovea. The central subfield thickness (r=-0.243, P=0.055 and foveal volume (r=0.216, P=0.09 did not correlate with age. Conclusion: Males and females differ significantly with regard to macular thickness and macular volume measurements. Reports by other studies that the increase in axial length reduced thickness and volume, were negated by this study which found a positive correlation among axial length, thickness, and volume. Keywords: macular thickness, macular volume, optical coherence tomography, Nepal

  2. Macular volume and central foveal thickness measurements in ...

    African Journals Online (AJOL)

    Objective: To determine macular volume and central foveal thickness measurements in normal eyes of healthy. Nigerian adults using Stratus optical coherence tomography. Subjects and Methods: Consenting 100 adults Nigerians with normal eyes were recruited and examined using Carl. Zeiss Stratus Optical Coherence ...

  3. Comparison and interchangeability of macular thickness measured with Cirrus OCT and Stratus OCT in myopic eyes

    Directory of Open Access Journals (Sweden)

    Geng Wang

    2015-12-01

    Full Text Available AIM: To investigate the difference of macular thickness measurements between stratus optical coherence tomography (OCT and Cirrus OCT (Carl Zeiss Meditec, Dublin, CA, USA in the same myopic patient and to develop a conversion equation to interchange macular thickness obtained with these two OCT devices. METHODS: Eighty-nine healthy Chinese adults with spherical equivalent (SE ranging from -1.13 D to -9.63 D were recruited. The macular thickness was measured by Cirrus OCT and Stratus OCT. The correlation between macular thickness and axial length and the agreement between two OCT measurements were evaluated. A formula was generated to interchange macular thickness obtained with two OCT devices. RESULTS: Average macular thickness measured with Stratus OCT (r=-0.280, P=0.008 and Cirrus OCT (r=-0.224, P=0.034 were found to be negatively correlated with axial length. No statistically significant correlation was found between axial length and central subfield macular thickness (CMT measured with Stratus OCT (r=0.191, P=0.073 and Cirrus OCT (r=0.169, P=0.113. The mean CMT measured with Cirrus OCT was 53.63±7.94 μm thicker than with Stratus OCT. The formula CMTCirrus OCT=78.328+0.874×CMTStratus OCT was generated to interchange macular thickness obtained with two OCT devices. CONCLUSION: Macular thickness measured with Cirrus OCT were thicker than with Stratus OCT in myopic eyes. A formula can be used to interchange macular thickness measured with two OCT devices in myopic eyes. Studies with different OCT devices and larger samples are warranted to enable the comparison of macular values measured with different OCT devices.

  4. [Macular thickness measured by optical coherence tomography in pseudoaphakic eyes with clear vs yellow implant].

    Science.gov (United States)

    Chamorro, E; Bonnin-Arias, C; Pérez-Carrasco, M J; Alvarez-Rementería, L; Villa-Collar, C; Armadá-Maresca, F; Sánchez-Ramos, C

    2014-04-01

    To study the use of optical coherence tomography (OCT), for measuring the macular thickness variations produced over time in elderly pseudophakic subjects implanted with a clear intraocular lens (IOL) in one eye, and a yellow IOL in the other eye. Macular thickness measurements were obtained in the 36 eyes of 18 subjects over 65 years, with cataracts surgically removed from both eyes and implanted with different absorbance (clear and yellow) IOLs in 2 separate surgeries. Stratus-OCT was used to determine the macular thickness in 2 sessions with 5 years of difference. After 5 years of follow-up, the eyes implanted with clear IOLs revealed a significant decrease in macular thickness. However, in eyes implanted with yellow IOLs the macular thickness remained stable. The mean overall decrease in macular thickness in eyes implanted with clear IOLs was 5 ± 8 μm (P=.02), and foveal thickness reduction was 10 ± 17 μm (P=.02). The macular thickness changes produced in eyes implanted with a yellow IOL differ from those with a clear IOL. These observation point to a possible protective effect of yellow IOL against the harmful effects of light in elderly pseudophakic subjects. However, studies with a longer follow-up are still needed to confirm that the protection provided by this IOL model is clinically significant. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  5. Relationship between macular thickness measurement and signal strength using Stratus optical coherence tomography

    OpenAIRE

    Segal, Ori; Shapira, Yinon; Gershoni, Assaf; Vainer, Igor; Nemet, Arie Y; Geffen, Noa; Mimouni, Michael

    2016-01-01

    Ori Segal,1 Yinon Shapira,2 Assaf Gershoni,1 Igor Vainer,2 Arie Y Nemet,1 Noa Geffen,1 Michael Mimouni2 1Department of Ophthalmology, Meir Medical Center, Kfar Saba, Israel and the Sackler School of Medicine, Tel Aviv University, Tel Aviv, 2Department of Ophthalmology, Rambam Health Care Campus, Haifa, Israel Purpose: To examine the relationship between signal strength and macular thickness as measured by Stratus optical coherence tomography (OCT)’s fast macular thickness protocol...

  6. Influence of age-related macular degeneration on macular thickness measurement made with fourier-domain optical coherence tomography.

    Science.gov (United States)

    Garas, Anita; Papp, András; Holló, Gábor

    2013-03-01

    To evaluate the influence of age-related macular degeneration (AMD) on macular thickness measurement made with Fourier-domain optical coherence tomography (RTVue-OCT) to detect glaucoma. : One nonglaucomatous eye of 79 white persons was imaged. This comprised 25 healthy eyes, 19 eyes with early/intermediate AMD (geographic atrophy excluded), 16 eyes with subfoveal choroidal neovascularization (CNV), and 19 CNV eyes after intravitreal antiangiogenic treatment [CNV-antivascular endothelial growth factor (VEGF)]. Compared with the age-matched controls, no difference in any nerve fiber layer and optic disc parameter was seen for any AMD group. No macular retinal segmentation error was detected in the control group. Localized inner retinal image segmentation errors topographically related to AMD were detected in 8 eyes with drusen (42.1%), all 16 CNV eyes (100%) and 17 eyes in the CNV-anti-VEGF group (89.5%; χ test, P0.05). In contrast, all pattern-based ganglion cell complex (GCC) parameters were significantly higher (more abnormal) in the CNV and CNV-anti-VEGF group than in the control eyes (Mann-Whitney test, Bonferroni correction, P<0.001). For GCC focal loss volume, the only pattern-based parameter classified by the software, the frequency of "borderline" and "outside normal limits" classifications was significantly greater in each AMD group than in the control group (χ test, Bonferroni correction, P ≤0.03). In nonglaucomatous eyes, AMD significantly influences the pattern-based inner macular thickness parameters of the RTVue optical coherence tomograph and the software-provided classification of GCC focal loss volume, for detection of glaucoma.

  7. Macular volume and central foveal thickness measurements in ...

    African Journals Online (AJOL)

    The mean macula volume was 6.79 + 0.392 µm3. It was 6.861 , 0.297 in males, 6.496 , 0.520 in females and was statistically higher in males than females (P = 0.000). The mean central foveal thickness (MCFT) was 149.58±32.470 µm. It was 154.49 ± 34.652 µm in males and 133.33 ± 15.315 µm in females. MCFT was ...

  8. New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection.

    Science.gov (United States)

    Nieves-Moreno, María; Martínez-de-la-Casa, José M; Bambo, María P; Morales-Fernández, Laura; Van Keer, Karel; Vandewalle, Evelien; Stalmans, Ingeborg; García-Feijoó, Julián

    2018-02-01

    This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Participants ( N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.

  9. Macular thickness and volume in the elderly

    DEFF Research Database (Denmark)

    Subhi, Yousif; Forshaw, Thomas; Sørensen, Torben Lykke

    2016-01-01

    manifests in the macula of the elderly focusing on clinical relevant measures that are thicknesses and volumes of different macular areas. Ageing seems to increase center point foveal thickness. Ageing does not seem to change the center subfield thickness significantly. Ageing decreases the inner and outer...

  10. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients...... with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS...... macular subfields. Repeatability was calculated according to methods described by Bland and Altman. RESULTS: 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm...

  11. Correlation between choroidal thickness and macular hole

    Directory of Open Access Journals (Sweden)

    Li-Li Wang

    2018-01-01

    Full Text Available AIM:To explore the correlation between choroidal thickness and macular hole, and to provide a theoretical basis for diagnosis and treatment of macular hole. METHODS: This study included 40 cases of monocular idiopathic macular hole patients who were treated in ophthalmology of our hospital from June 2015 to June 2016 and 40 cases of healthy people. Sicked eyes of idiopathic macular hole patients(40 eyeswere set as the Group A, uninjured side eyes(40 eyeswere set as the Group B, eyes of 40 cases of healthy people(40 normal eyeswere set as the Group C. Choroidal thickness of macular fovea, macular fovea 1mm, 3mm at 9 points, 4 directions in the upper, lower, nasal and temporal regions were measured through coherent optical tomography of enhanced deep imaging(enhanced depth image optical coherence tomography, EDI-OCT. They were recorded as SFCT, SCT1mm, SCT3mm, ICT1mm, ICT3mm, NCT1mm, NCT3mm, TCT1mm, TCT3mm, and correlation analysis between SFCT and age was analyzed. RESULTS: Average SFCT of Group A, B had no significant difference, data of the Group C was significantly higher than those of the Group A, B, there was statistical significance(P1mm, SCT3mm, ICT1mm, ICT3mm, NCT1mm, NCT3mm, TCT1mm, TCT3mm of the Group A, B had no significant difference(P>0.05, and choroidal thickness at each point of the Group C was significantly higher than that of Group A and B, there was statistical significance(Pr=-0.065, P=0.148; r=-0.057, P=0.658, SFCT of the Group C was negatively correlated with age(r=-0.343, P=0.041. CONCLUSION: The pathogenesis of idiopathic macular hole may be related to the sharp decrease of choroidal thickness, choroidal thickness of uninjured side eyes reduces more sharply than normal population and choroidal vascular metabolism reduces may be pathogenic.

  12. Segmentation error and macular thickness measurements obtained with spectral-domain optical coherence tomography devices in neovascular age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Moosang Kim

    2013-01-01

    Full Text Available Purpose: To evaluate frequency and severity of segmentation errors of two spectral-domain optical coherence tomography (SD-OCT devices and error effect on central macular thickness (CMT measurements. Materials and Methods: Twenty-seven eyes of 25 patients with neovascular age-related macular degeneration, examined using the Cirrus HD-OCT and Spectralis HRA + OCT, were retrospectively reviewed. Macular cube 512 × 128 and 5-line raster scans were performed with the Cirrus and 512 × 25 volume scans with the Spectralis. Frequency and severity of segmentation errors were compared between scans. Results: Segmentation error frequency was 47.4% (baseline, 40.7% (1 month, 40.7% (2 months, and 48.1% (6 months for the Cirrus, and 59.3%, 62.2%, 57.8%, and 63.7%, respectively, for the Spectralis, differing significantly between devices at all examinations (P < 0.05, except at baseline. Average error score was 1.21 ± 1.65 (baseline, 0.79 ± 1.18 (1 month, 0.74 ± 1.12 (2 months, and 0.96 ± 1.11 (6 months for the Cirrus, and 1.73 ± 1.50, 1.54 ± 1.35, 1.38 ± 1.40, and 1.49 ± 1.30, respectively, for the Spectralis, differing significantly at 1 month and 2 months (P < 0.02. Automated and manual CMT measurements by the Spectralis were larger than those by the Cirrus. Conclusions: The Cirrus HD-OCT had a lower frequency and severity of segmentation error than the Spectralis HRA + OCT. SD-OCT error should be considered when evaluating retinal thickness.

  13. Consistency of ocular coherence tomography fast macular thickness mapping in diabetic diffuse macular edema

    International Nuclear Information System (INIS)

    Saraiva, Fabio Petersen; Costa, Patricia Grativol; Inomata, Daniela Lumi; Melo, Carlos Sergio Nascimento; Helal Junior, John; Nakashima, Yoshitaka

    2007-01-01

    Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map was chosen. The consistency in measurements of foveal thickness, foveal volume, and total macular volume for both groups was evaluated using the Pearson's coefficient of variation. The T-test for independent samples was used in order to compare measurements of both groups. Results: Each group consisted of 20 patients. All measurements had a coefficient of variation less than 10%. The most consistent parameter for both groups was the total macular volume. Discussion: Consistency in measurement is a mainstay of any test. A test is unreliable if its measurements can not be correctly repeated. We found a good index of consistency, even considering patients with an unstable gaze. Conclusions: Optical coherence tomography is a consistent method for diabetic subjects with diffuse macular edema. (author)

  14. Consistency of ocular coherence tomography fast macular thickness mapping in diabetic diffuse macular edema

    Energy Technology Data Exchange (ETDEWEB)

    Saraiva, Fabio Petersen; Costa, Patricia Grativol; Inomata, Daniela Lumi; Melo, Carlos Sergio Nascimento; Helal Junior, John; Nakashima, Yoshitaka [Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Dept. de Oftalmologia]. E-mail: fabiopetersen@yahoo.com.br

    2007-07-01

    Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map was chosen. The consistency in measurements of foveal thickness, foveal volume, and total macular volume for both groups was evaluated using the Pearson's coefficient of variation. The T-test for independent samples was used in order to compare measurements of both groups. Results: Each group consisted of 20 patients. All measurements had a coefficient of variation less than 10%. The most consistent parameter for both groups was the total macular volume. Discussion: Consistency in measurement is a mainstay of any test. A test is unreliable if its measurements can not be correctly repeated. We found a good index of consistency, even considering patients with an unstable gaze. Conclusions: Optical coherence tomography is a consistent method for diabetic subjects with diffuse macular edema. (author)

  15. Macular thickness after glaucoma filtration surgery.

    Science.gov (United States)

    Sesar, Antonio; Cavar, Ivan; Sesar, Anita Pusić; Geber, Mia Zorić; Sesar, Irena; Laus, Katia Novak; Vatavuk, Zoran; Mandić, Zdravko

    2013-09-01

    The aim of present study was to analyze early postoperative changes in the macular area using optical coherence tomography (OCT) after uncomplicated glaucoma filtration surgery. This prospective study included 32 patients (34 eyes) with open-angle glaucoma, which underwent trabeculectomy with or without use of mitomycin C. Exclusion criteria were macular edema, uveitis, age-related macular degeneration, blurred optical media, secondary glaucoma and angle-closure glaucoma. All standard clinical examinations were made before surgery, at the 2nd day, 1 week and 1 month after surgery. Tomography of the macula was performed during every examination using Cirrus HD OCT for the analysis of central subfield thickness. Results show that thickening of the macula was slightly higher 1 week and 1 month after operation in comparison with baseline end 2nd day postoperativelly. There was no significant difference in the change of macular thickness in patients who have used topical prostaglandins compared with those who have used other topical medications. Also, there was no difference in macular changes between patients treated with or without mitomycin C. In conclusion, we found a slight subclinical increase in macular thickness after uncomplicated trabeculectomy, for which we considered that was the result in reduction of intraocular pressure after glaucoma surgery. Macular thickening after glaucoma filtering surgery could be a physiological reaction to the stress of the retina caused by a sudden reduction of intraocular pressure and it is the consequence of altered relationship between capillary pressure and interstitial fluid pressure.

  16. Quantitative analysis of macular retinal thickness and macular volume in diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Ying Zhao

    2017-12-01

    Full Text Available AIM: To evaluate and characterize the macular thickness and macular volume in patients of different stages of diabetic retinopathy with special-domain optical coherence tomography(SD-OCT. METHODS: Totally 40 patients(78 eyeswith diabetic retinopathy were recruited in the study from January 2016 to January 2017 in our hospital. According to the international clinical classification of diabetic retinopathy, 20 cases(40 eyeswere categorized as non-proliferative diabetic retinopathy(NPDRgroup and 20 cases proliferative diabetic retinopathy(PDRgroup(38 eyes. All subjects were examined and analyzed with Early Treatment Diabetic Retinopathy Study(ETDRSsubfields, which were embedded in HS(Haag-Streitwith diameter of 1, 3 and 6mm.The changes of retinal thickness and volume of the macular center were measured. RESULTS: The thickness of macular foveolar in NPDR group and PDR group were 252.57±31.36μm, 362.47±20.81μm. The retinal thickness of inner superior subfield(ISMand inner nasal subfield(INMwere the thickest; that of inner inferior subfield(IIMwas next to ISM and INM, and that of inner temporal subfield was the thinnest. Of the outer subfields, the retinal thickness of outer superior subfield(OSMwas the thickest; that of outer nasal subfield(ONMwas next to OSM, and that of outer temporal subfield(OTMand outer inferior subfield(OIMwas the thinnest. The value of macular central concave thickness and retinal thickness in each quadrant of the NPDR group were less than those of the PDR group, the difference was statistically significant(P3, 0.28±0.16mm3, the upper and nasal sides of the middle part of the partition were the largest, the inferior and the temporal side were the smallest. The nasal side of the outer loop was the largest, the upper was the second, the temporal side and the inferior were the smallest. The volume of macular central fovea and the retinal volume in each quadrant of the NPDR group were smaller than those of the PDR group, the

  17. Relationship between macular ganglion cell complex thickness and macular outer retinal thickness: a spectral-domain optical coherence tomography study.

    Science.gov (United States)

    Kita, Yoshiyuki; Kita, Ritsuko; Takeyama, Asuka; Anraku, Ayako; Tomita, Goji; Goldberg, Ivan

    2013-01-01

    To assess the relationship between macular ganglion cell complex and macular outer retinal thicknesses. Case-control study. Forty-two normal eyes and 91 eyes with primary open-angle glaucoma were studied. Spectral-domain optical coherence tomography (RTVue-100) was used to measure the macular ganglion cell complex and macular outer retinal thickness. Ganglion cell complex to outer retinal thickness ratio was also calculated. The relationships between the ganglion cell complex and outer retinal thicknesses and between the ganglion cell complex to outer retinal thickness ratio and outer retinal thickness were evaluated. There was a positive correlation between ganglion cell complex and outer retinal thicknesses in the normal group and the glaucoma group (r = 0.53, P variation in the outer retinal thickness. Therefore, when determining the ganglion cell complex, it seems necessary to consider the outer retinal thickness as well. We propose the ratio as a suitable parameter to account for individual variations in outer retinal thickness. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  18. Long-term changes of macular retinal thickness after idiopathic macular hole surgery

    Directory of Open Access Journals (Sweden)

    Yan Yang

    2014-12-01

    Full Text Available AIM:To determine the changes of regional macular retinal thickness(RTwith spectral domain optical coherence tomography(SD-OCTafter successful pars plana vitrectomy(PPVsurgery with inner limiting membrane(ILMpeeling in patients with idiopathic macular hole.METHODS:A non-randomized retrospective case study on 17 patients(17 eyeswho were hospitalized between March 1, 2011 and June 30, 2013. All 17 eyes had been diagnosed with idiopathic macular hole and thereafter underwent 25G-PPV surgeries performed by the same surgeon with ILM peeling and short-term gas tamponade. In the 6mo-plus follow-up after surgery, these eyes were found to have successful closure in the macular hole. The macular RT of the nine areas in the Early Treatment Diabetic Retinopathy Study was measured by SD-OCT. All patients were applied by SD-OCT with linear scan of the macular. At least four examinations on the operated eye were conducted in contrast to the other normal eye: before the surgery, 3~5wk after the surgery(stage A, 2~3mo after the surgery(stage B, and >6mo after the surgery(stage C.RESULTS:In stage A, the macular RT of operated eyes in the areas of C, IS, II, IN, OS, OI, ON(263.00±39.48, 313.92±18.35, 311.00±18.02, 335.67±19.91, 280.83±33.74, 269.92±23.32, 307.00±28.40were significantly thicker than the corresponding areas of the normal fellow eyes(220.51±23.94, 292.08±21.93, 282.50±20.30, 288.33±20.76, 251.25±17.60, 247.75±21.48, 265.17±24.76μm(PP>0.01. In Stage B, the macular RT in the areas of II, IN, OS(335.67±19.20,319.75±19.20, 273.50±16.89μmwere significantly thicker than the corresponding areas of the normal fellow eyes(286.33±20.46, 293.42±17.64, 252.50±16.32μm(PP> 0.01. In Stage C, the macular RT of operated eyes with the areas of IN(321.17±19.71μmwere significantly thicker than the corresponding areas of the normal fellow eyes(296.25±19.57μm(PP>0.01. Moreover, the macular RT of operated eyes in the areas of ON, IT(307.00±28

  19. The Distribution of Macular Thickness and Its Determinants in a Healthy Population.

    Science.gov (United States)

    Hashemi, Hassan; Khabazkhoob, Mehdi; Yekta, AbbasAli; Emamian, Mohammad Hassan; Nabovati, Payam; Fotouhi, Akbar

    2017-10-01

    To determine the distribution of macular thickness in a healthy Iranian population aged 45-69 years and its association with certain determinants. All participants underwent optometric examinations including measurement of uncorrected and corrected visual acuity, objective refraction by retinoscopy, and subjective refraction. Subsequently, all participants underwent slit-lamp biomicroscopy followed by fundus examination through direct and indirect ophthalmoscopy, and optical coherence tomography (OCT) imaging under pupil dilation. Mean central macular thickness was 255.4 µm (95% confidence interval, CI, 254.5-256.3 µm), average inner macular thickness was 316.5 µm (95% CI 315.9-317.1 µm), average outer macular thickness was 275.3 µm (95% CI 274.8-275.8 µm), and overall average thickness was 278.6 µm (95% CI 278.1-279.1 µm). A linear multiple regression model showed that all indexes were significantly larger in male participants (p < 0.001). Central macular thickness increased with age (coef = 0.25, p < 0.001) while overall, inner and outer macular thickness decreased with age (coef = -0.18, -0.15, -0.19, respectively, all p < 0.001). Central and inner macular thickness had a positive correlation (coef = 3.8, 2.6, respectively, both p < 0.001) and outer macular thickness had a negative correlation (coef = -1.6, p < 0.001) with axial length. Age, sex, refractive error, axial length, and keratometry were found to be associated with macular thickness. These factors should be taken into account when interpreting macular thickness measurements with spectral-domain OCT.

  20. Quantification of retinal layer thickness changes in acute macular neuroretinopathy

    DEFF Research Database (Denmark)

    Munk, Marion R.; Beck, Marco; Kolb, Simone

    2017-01-01

    Purpose To quantitatively evaluate retinal layer thickness changes in acute macular neuroretinopathy (AMN). Methods AMN areas were identified using near-infrared reflectance (NIR) images. Intraretinal layer segmentation using Heidelberg software was performed. The inbuilt ETDRS -grid was moved on...

  1. Interocular Symmetry in Macular Choroidal Thickness in Children

    Directory of Open Access Journals (Sweden)

    Christiane Al-Haddad

    2014-01-01

    Full Text Available Objective. To report interocular differences in choroidal thickness in children using spectral domain optical coherence tomography (SD-OCT and correlate findings with biometric data. Methods. This observational cross-sectional study included 91 (182 eyes healthy children aged 6 to 17 years with no ocular abnormality except refractive error. After a comprehensive eye exam and axial length measurement, high definition macular scans were performed using SD-OCT. Two observers manually measured the choroidal thickness at the foveal center and at 1500 µm nasally, temporally, inferiorly, and superiorly. Interocular differences were computed; correlations with age, gender, refractive error, and axial length were performed. Results. Mean age was 10.40 ± 3.17 years; mean axial length and refractive error values were similar between fellow eyes. There was excellent correlation between the two observers’ measurements. No significant interocular differences were observed at any location. There was only a trend for right eyes to have higher values in all thicknesses, except the superior thickness. Most of the choroidal thickness measurements correlated positively with spherical equivalent but not with axial length, age, or gender. Conclusion. Choroidal thickness measurements in children as performed using SD-OCT revealed a high level of interobserver agreement and consistent interocular symmetry. Values correlated positively with spherical equivalent refraction.

  2. Interocular symmetry in macular choroidal thickness in children.

    Science.gov (United States)

    Al-Haddad, Christiane; El Chaar, Lama; Antonios, Rafic; El-Dairi, Mays; Noureddin, Baha'

    2014-01-01

    Objective. To report interocular differences in choroidal thickness in children using spectral domain optical coherence tomography (SD-OCT) and correlate findings with biometric data. Methods. This observational cross-sectional study included 91 (182 eyes) healthy children aged 6 to 17 years with no ocular abnormality except refractive error. After a comprehensive eye exam and axial length measurement, high definition macular scans were performed using SD-OCT. Two observers manually measured the choroidal thickness at the foveal center and at 1500 µm nasally, temporally, inferiorly, and superiorly. Interocular differences were computed; correlations with age, gender, refractive error, and axial length were performed. Results. Mean age was 10.40 ± 3.17 years; mean axial length and refractive error values were similar between fellow eyes. There was excellent correlation between the two observers' measurements. No significant interocular differences were observed at any location. There was only a trend for right eyes to have higher values in all thicknesses, except the superior thickness. Most of the choroidal thickness measurements correlated positively with spherical equivalent but not with axial length, age, or gender. Conclusion. Choroidal thickness measurements in children as performed using SD-OCT revealed a high level of interobserver agreement and consistent interocular symmetry. Values correlated positively with spherical equivalent refraction.

  3. Visual Acuity is Related to Parafoveal Retinal Thickness in Patients with Retinitis Pigmentosa and Macular Cysts

    Science.gov (United States)

    Brockhurst, Robert J.; Gaudio, Alexander R.; Berson, Eliot L.

    2008-01-01

    Purpose To quantify the prevalence and effect on visual acuity of macular cysts in a large cohort of patients with retinitis pigmentosa. Methods In 316 patients with typical forms of retinitis pigmentosa, we measured visual acuities with Early Treatment Diabetic Retinopathy Study (ETDRS) charts, detected macular cysts with optical coherence tomography (OCT), and quantified retinal thicknesses by OCT. We used the FREQ, LOGISTIC, and GENMOD procedures of SAS to evaluate possible risk factors for cyst prevalence and the MIXED procedure to quantify the relationships of visual acuity to retinal thickness measured at different locations within the macula. Results We found macular cysts in 28% of the patients, 40% of whom had cysts in only one eye. Macular cysts were seen most often in patients with dominant disease and not at all in patients with X-linked disease (p = 0.006). In eyes with macular cysts, multiple regression analysis revealed that visual acuity was inversely and independently related to retinal thickness at the foveal center (p = 0.038) and within a ring spanning an eccentricity of 5° to 10° from the foveal center (p = 0.004). Conclusions Macular cysts are a common occurrence in retinitis pigmentosa, especially among patients with dominantly-inherited disease. Visual acuity is influenced by edema in the parafovea, as well as in the fovea. PMID:18552390

  4. Choroidal thickness in Malaysian eyes with full-thickness macular holes

    Directory of Open Access Journals (Sweden)

    Chew Y Tan

    2018-02-01

    Full Text Available AIM: To compare choroidal thickness at the macula in eyes with unilateral idiopathic full-thickness macular holes(FTMHwith that of unaffected fellow eyes, and eyes of normal control patients.METHODS: Cross-sectional study. Thirty patients with unilateral idiopathic FTMH and thirty age, sex, and race-matched controls were recruited. Axial lengths were measured using laser interferometry. Enhanced depth imaging optical coherence tomography images were obtained using Heidelberg spectral-domain optical coherence tomography. Choroidal thickness was measured at the fovea, and at 1 mm and 2 mm nasally, temporally, superiorly and inferiorly from the center of the fovea. Statistical analysis was performed using independent and paired t-tests, chi-square tests, and Pearson correlation tests(PRESULTS: The mean subfoveal choroidal thickness was 201.0±44.0 μm in the FTMH group, 225.3±51.4 μm in the fellow eye group and 262.3±70.3 μm in the control group. The choroid was thinner in FTMH eyes at all locations when compared to control eyes(PPP>0.05. Choroidal thickness was generally highest subfoveally and lowest nasally. Subfoveal choroidal thickness was negatively correlated with age(r=-0.278, P=0.032, and axial length(r=-0.328, P=0.011.CONCLUSION: Choroidal thickness is lower in both eyes of patients with unilateral FTMH compared to healthy control eyes.

  5. Evaluation of Macular Thickness by Optical Coherence Tomography After Phacoemulsification Surgery

    Directory of Open Access Journals (Sweden)

    Mehmet Tetikoğlu

    2014-03-01

    Full Text Available Objectives: To evaluate the incidence of cystoid macular edema (CME, its risk factors, and macular changes by optical coherence tomography (OCT after phacoemulsification. Materials and Methods: This study included 99 eyes of 65 patients who underwent phacoemulsification surgery in Okmeydanı Training and Research Hospital, Department of Ophthalmology. Foveal thickness, macular volume, and mean macular thickness were measured by OCT preoperatively and at 1st day, 1st week, 1st, and 3rd months postoperatively. Results: In this study, the incidence of postoperative CME was 3%. The mean central foveal thickness was preoperatively 250.4 (±18.5 μm, and postoperatively was 252.08 (±23.2 μm at 1st day, 261.4 (±27.8 μm at 1st week, 270.6 (±44.4 μm at 1st month, and 265.4 (±41.6 μm at 3rd month. The statistically significant increase in foveal thickness was defined between preoperative and 1st week, 1st month, 3rd month as well as between 1st week, 1st month, and 3rd month (p<0.01. Increase in macular thickness was demonstrated in 44 eyes (44.4% which was most frequently located in the parafoveal region. Intraoperative complications like iris trauma, posterior capsule tear, and vitreous loss were increased risk of CME (p=0.001. Conclusion: Subclinical macular thickness increment begins at 1st week and reaches maximum point at 1st month. Incidence of CME increased in patients who had a complicated cataract surgery, so they should be followed closely by OCT. (Turk J Ophthalmol 2014; 44: 88-91

  6. Correlation between Macular Thickness and Visual Field in Early Open Angle Glaucoma: A Cross-Sectional Study.

    Science.gov (United States)

    Fallahi Motlagh, Behzad; Sadeghi, Ali

    2017-01-01

    The aim of this study was to correlate macular thickness and visual field parameters in early glaucoma. A total of 104 eyes affected with early glaucoma were examined in a cross-sectional, prospective study. Visual field testing using both standard automated perimetry (SAP) and shortwave automated perimetry (SWAP) was performed. Global visual field parameters, including mean deviation (MD) and pattern standard deviation (PSD), were recorded and correlated with spectral domain optical coherence tomography (SD-OCT)-measured macular thickness and asymmetry. Average macular thickness correlated significantly with all measures of visual field including MD-SWAP (r = 0.42), MD-SAP (r = 0.41), PSD-SWAP (r = -0.23), and PSD-SAP (r = -0.21), with P-values field parameters in early glaucoma. The results of this study should make macular thickness measurements even more meaningful to glaucoma specialists.

  7. [Features associated with retinal thickness extension in diabetic macular oedema].

    Science.gov (United States)

    Razo Blanco-Hernández, Dulce Milagros; Lima-Gómez, Virgilio; García-Rubio, Yatzul Zuhaila

    2015-01-01

    Clinically significant macular edema has features that are associated with a major risk of visual loss, with thickening that involves the centre of the macula, field 7 or visual deficiency, although it is unknown if these features are related to retinal thickness extension. An observational, analytical, prospective, cross-sectional and open study was conducted. The sample was divided into initial visual acuity ≥0.5, central field thickness, center point thickness, field 7 and macular volume more than the reported 2 standard deviation mean value in eyes without retinopathy. The extension was determined by the number of the central field area equivalent thickening and these features were compared with by Student's t test for independent samples. A total of 199 eyes were included. In eyes with visual acuity of ≥0.5, the mean extension was 2.88±1.68 and 3.2±1.63 in area equivalent in eyes with visual acuity 0.5 (p=0.12). The mean extension in eyes with less than 2 standard deviation of central field thickness, center point thickness, field 7 and macular volume was significantly lower than in eyes with more than 2 standard deviations (1.9±0.93 vs. 4.07±1.49, 2.44±1.47 vs. 3.94±1.52, 1.79±1.07 vs. 3.61±1.57 and 1.6±0.9 vs. 3.9±1.4, respectively, p<0.001). The extension of retinal thickness is related with the anatomical features reported with a greater risk of visual loss, but is not related to initial visual deficiency. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  8. Comparisons of retinal nerve fiber layer thickness changes after macular hole surgery

    Directory of Open Access Journals (Sweden)

    Nelson Chamma Capelanes

    Full Text Available ABSTRACT Purpose: To compare postoperative changes in retinal nerve fiber layer thickness in patients with macular holes treated with vitrectomy with Brilliant Blue-assisted internal limiting membrane peeling. Methods: Twenty-two eyes of 20 patients with macular holes were studied. Each eye was selected to undergo Brilliant Blue-assisted internal limiting membrane peeling. The circumferential retinal nerve fiber layer thickness was determined using spectral domain optical coherence tomography preoperatively and 2 months postoperatively. Mean overall and sectoral retinal nerve fiber layer thicknesses were obtained for each patient. Results: There was no statistically significant difference (p≥0.05 between the pre- and post-treatment measurements in relation to each CFN variable, i.e., on average, pre-treatment measures were the same as post-treatment measures. Furthermore, despite the differences between the pre- and post-treatment measures always being positive (pre-post >0, they are not statistically significant. Conclusions: This study showed no significant decrease in retinal nerve fiber layer thickness measurements after macular holes surgery, regardless of age or sex.

  9. Macular Choroidal Small-Vessel Layer, Sattler's Layer and Haller's Layer Thicknesses: The Beijing Eye Study.

    Science.gov (United States)

    Zhao, Jing; Wang, Ya Xing; Zhang, Qi; Wei, Wen Bin; Xu, Liang; Jonas, Jost B

    2018-03-13

    To study macular choroidal layer thickness, 3187 study participants from the population-based Beijing Eye Study underwent spectral-domain optical coherence tomography with enhanced depth imaging for thickness measurements of the macular small-vessel layer, including the choriocapillaris, medium-sized choroidal vessel layer (Sattler's layer) and large choroidal vessel layer (Haller's layer). In multivariate analysis, greater thickness of all three choroidal layers was associated (all P  0.05) associated with the prevalence of open-angle glaucoma or diabetic retinopathy. There was a tendency (0.07 > P > 0.02) toward thinner choroidal layers in chronic angle-closure glaucoma. The ratio of small-vessel layer thickness to total choroidal thickness increased (P layer and Haller's layer thickness to total choroidal thickness decreased. A higher ratio of small-vessel layer thickness to total choroidal thickness was significantly associated with a lower prevalence of AMD (early type, intermediate type, late geographic type). Axial elongation-associated and aging-associated choroidal thinning affected Haller's and Sattler's layers more markedly than the small-vessel layer. Non-exudative and exudative AMD, except for geographic atrophy, was associated with slightly increased choroidal thickness.

  10. Evaluation of macular thickness change after inferior oblique muscle recession surgery

    Directory of Open Access Journals (Sweden)

    Ece Turan-Vural

    2014-01-01

    Full Text Available Purpose: This study aimed to evaluate the changes in macular thickness following inferior oblique muscle recession surgery. Materials and Methods: Thirty-eight eyes from 21 patients undergoing ocular muscle surgery were included. Patients were grouped into three groups based on the type of surgical intervention: Group I (n = 12, inferior oblique recession surgery alone; Group II (n = 12, inferior oblique plus horizontal muscle surgery; Group III (n = 14, horizontal muscle surgery alone. Each eye was scanned using the optical coherence tomography (OCT device preoperatively and on the first postoperative day to measure macular thickness. Results: Following surgery, a significant increase in foveal thickness occurred in Group I (P < 0.05 and Group II (P < 0.01. In addition, a statistically significant difference was observed between the groups with regard to the increase in foveal thickness (P = 0.016, with significantly lower changes in Group III. Conclusion: Our findings suggested that inferior oblique muscle recession surgery is associated with an increase in macular thickness.

  11. Spectral-domain Optical Coherence Tomography Retinal and Choroidal Thickness Metric Repeatability in Age-related Macular Degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2016-01-01

    : Enrolled patients underwent repeated SDOCT imaging using the Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany). A single technician certified for clinical trials took 3 macular volume scans. Retinal thicknesses were calculated for each of the 9 Early Treatment Diabetic Retinopathy Study (ETDRS...... was 34.7 μm (95% CI 33.7-35.7 μm). CONCLUSIONS: This study suggests that a change of greater than 31 μm in Spectralis SDOCT-derived retinal thickness measurement of the central macular subfield and 35 μm in subfoveal choroidal thickness is necessary to detect true clinical change associated with disease...

  12. Comparison of macular choroidal thickness among patients older than age 65 with early atrophic age-related macular degeneration and normals.

    Science.gov (United States)

    Sigler, Eric J; Randolph, John C

    2013-09-19

    To compare macular choroidal thickness between patients older than 65 years with early atrophic age-related macular degeneration (AMD) and normals. This was a consecutive, cross-sectional observational study. Enhanced depth imaging spectral-domain optical coherence tomography using horizontal raster scanning at 12 locations throughout the macula was performed in one eye of consecutive patients presenting with large soft drusen alone, drusen with additional features of early AMD, or a normal fundus. Choroidal thickness was measured at 7 points for each raster scan in the central 3 mm of the macula (total 84 points per eye). In addition, a single subfoveolar measurement was obtained for each eye. One hundred fifty eyes of 150 patients were included. There was no significant difference between mean refractive error for each diagnosis category via one-way ANOVA (P = 0.451). Mean macular choroidal thickness (CT) was 235 ± 49 μm (range, 125-334 μm; median 222 μm) for normals, 161 ± 39 μm (range, 89-260 μm; median = 158 μm) for the drusen group, and 115 ± 40 μm (range, 22-256 μm; median = 112 μm) for patients with AMD. Mean macular CT was significantly different via one-way ANOVA among all diagnosis categories (P < 0.001). The presence of features of early AMD without geographic atrophy and/or soft drusen alone is associated with decreased mean macular CT in vivo compared to that in patients with no chorioretinal pathology. Using enhanced depth imaging, measurement of a single subfoveolar choroidal thickness is highly correlated to mean central macular CT.

  13. Morphision: A method for subjective evaluation of metamorphopsia in patients with unilateral macular pathology (i.e., full thickness macular hole and epiretinal membrane

    Directory of Open Access Journals (Sweden)

    Marta Ugarte

    2013-01-01

    Full Text Available Background: Lack of clinical tests to quantify spatial components of distortion in patients with full thickness macular holes (FTMH and epiretinal membranes (ERM. Aim: To develop a test for subjective evaluation of visual distortion in the central visual field around fixation in patients with unilateral FTMH or ERM. Settings and Design: Prospective case-control study carried out at tertiary referral center. Materials and Methods: Twenty-five patients with unilateral macular disease (13 macular epiretinal membranes, 12 full-thickness macular holes, and nine controls (without ocular pathology underwent ophthalmological examination with logMAR ETDRS visual acuity, near vision and contrast sensitivity assessed. Macular optical coherence tomography and metamorphopsia assessment using Morphision test was also carried out. This test consists of a set of modified Amsler charts for detection, identification, and subjective quantification of visual distortion in the central visual field around fixation. Morphision test content and construct validity, and reliability (test-retest method were evaluated. Sixteen patients completed an unstructured survey on test performance and preference. Results: Every patient with unilateral FTMH or ERM identified a particular chart using Morphision test (content validity. None of the normal subjects without symptoms of metamorphopsia identified any distortion (construct validity. Test-retest showed a 100% consistency for frequency and 67% for amplitude. The mean amplitude difference between measurements was 0.02 degrees (SD = 0.038. The coefficient of repeatability was 0.075. There was a correlation between Morphision amplitude score and visual acuity and contrast sensitivity, individually. Conclusions: Morphision test allowed detection and subjective quantification of metamorphopsia in the clinical setting in our patients with unilateral macular epiretinal membranes and full thickness macular holes.

  14. Epiretinal proliferation in lamellar macular holes and full-thickness macular holes: clinical and surgical findings.

    Science.gov (United States)

    Lai, Tso-Ting; Chen, San-Ni; Yang, Chung-May

    2016-04-01

    To report the clinical findings and surgical outcomes of lamellar macular holes (LMH) with or without lamellar hole-associated epiretinal proliferation (LHEP), and those of full-thickness macular holes (FTMH) presenting with LHEP. From 2009 to 2013, consecutive cases of surgically treated LMH, and all FTMH cases with LHEP were reviewed, given a follow-up time over 1 year. In the LMH group (43 cases), those with LHEP (19 cases) had significantly thinner bases and larger openings than those without (24 cases). The rate of disrupted IS/OS line was higher in the LHEP subgroup preoperatively (68.4 % vs 37.5 %), but similar between subgroups postoperatively (36.8 % and 33.3 %). The preoperative and postoperative visual acuity showed no significant difference between two subgroups. In the FTMH group (13 cases), the average hole size was 219.2 ± 92.1 μm. Permanent or transient spontaneous hole closure was noted in 69.2 % of cases. An intact IS-OS line was found in only 23 % of cases at the final follow-up. In the LMH group, LHEP was associated with a more severe defect but didn't affect surgical outcomes. In the FTMH group, spontaneous hole closure was frequently noted. Despite small holes, disruption of IS-OS line was common after hole closure.

  15. Vitrectomy with Internal Limiting Membrane Peeling versus No Peeling for Idiopathic Full-Thickness Macular Hole

    DEFF Research Database (Denmark)

    Spiteri Cornish, Kurt; Lois, Noemi; Scott, Neil W

    2014-01-01

    OBJECTIVE: To determine whether internal limiting membrane (ILM) peeling improves anatomic and functional outcomes of full-thickness macular hole (FTMH) surgery when compared with the no-peeling technique. DESIGN: Systematic review and individual participant data (IPD) meta-analysis undertaken...... under the auspices of the Cochrane Eyes and Vision Group. Only randomized controlled trials (RCTs) were included. PARTICIPANTS AND CONTROLS: Patients with idiopathic stage 2, 3, and 4 FTMH undergoing vitrectomy with or without ILM peeling. INTERVENTION: Macular hole surgery, including vitrectomy and gas...... endotamponade with or without ILM peeling. MAIN OUTCOME MEASURES: Primary outcome was best-corrected distance visual acuity (BCdVA) at 6 months postoperatively. Secondary outcomes were BCdVA at 3 and 12 months; best-corrected near visual acuity (BCnVA) at 3, 6, and 12 months; primary (after a single surgery...

  16. Analysis the macular ganglion cell complex thickness in monocular strabismic amblyopia patients by Fourier-domain OCT

    Directory of Open Access Journals (Sweden)

    Hong-Wei Deng

    2014-11-01

    Full Text Available AIM: To detect the macular ganglion cell complex thickness in monocular strabismus amblyopia patients, in order to explore the relationship between the degree of amblyopia and retinal ganglion cell complex thickness, and found out whether there is abnormal macular ganglion cell structure in strabismic amblyopia. METHODS: Using a fourier-domain optical coherence tomography(FD-OCTinstrument iVue®(Optovue Inc, Fremont, CA, Macular ganglion cell complex(mGCCthickness was measured and statistical the relation rate with the best vision acuity correction was compared Gman among 26 patients(52 eyesincluded in this study. RESULTS: The mean thickness of the mGCC in macular was investigated into three parts: centrial, inner circle(3mmand outer circle(6mm. The mean thicknesses of mGCC in central, inner and outer circle was 50.74±21.51μm, 101.4±8.51μm, 114.2±9.455μm in the strabismic amblyopia eyes(SAE, and 43.79±11.92μm,92.47±25.01μm, 113.3±12.88μm in the contralateral sound eyes(CSErespectively. There was no statistically significant difference among the eyes(P>0.05. But the best corrected vision acuity had a good correlation rate between mGcc thicknesses, which was better relative for the lower part than the upper part.CONCLUSION:There is a relationship between the amblyopia vision acuity and the mGCC thickness. Although there has not statistically significant difference of the mGCC thickness compared with the SAE and CSE. To measure the macular center mGCC thickness in clinic may understand the degree of amblyopia.

  17. Retinal thickness measurement and evaluation of natural history of the diabetic macular edema through optical coherence tomography Medida da espessura retiniana e avaliação da história natural do edema macular diabético pela tomografia de coerência óptica

    Directory of Open Access Journals (Sweden)

    Rosana Zacarias Hannouche

    2009-08-01

    Full Text Available PURPOSE: 1 Diagnose, through optical coherence tomography (OCT exam, the occurrence of diabetic macular edema in patients with diabetic retinopathy and visual acuity of 20/40 or better, by measuring the foveal center point thickness, during one year. 2 Evaluate the edema natural history, during this period, associating the center point thickness with hemoglobin A1c and changes in visual acuity. 3 Correlate the obtained results with the control group. METHODS: A prospective study was done, of a sample of 30 patients with diabetic macular edema and visual acuity of 20/40 or better. Measurements of the best corrected visual acuity, hemoglobin A1c level, biomicroscopy with 78-diopter lens, fluorescein angiogram and optical coherence tomography were made. The retinal thickness was selected as the main variable. Besides descriptive statistics, additional tests were applied to analyze the results and determine the correlation between these variables, such as t-Student, Chi-Square, Tukey and ANOVA. The relation of optical coherence tomography with visual acuity and hemoglobin A1c was studied through linear regression. RESULTS: It was found that there is no significant difference between patients and normal individuals, for the variables age and gender. The values of center point thickness found for men were greater than those for women, showing the influence of gender on that thickness. As many as 83.33% of the diabetic patients with clinically significant macular edema presented moderate non-proliferative diabetic retinopathy (NPDR, 10% presented mild NPDR and 6.66% severe non-proliferative diabetic retinopathy. Patients under combined treatment of insulin and oral hypoglycemiant presented influence on the results of center point thickness (through OCT and visual acuity. The mean duration of diabetes was 9.63 years. Values of center point thickness were always found greater for patients than those for normal eyes. Levels of hemoglobin A1c did not have

  18. Normative spectral domain optical coherence tomography data on macular and retinal nerve fiber layer thickness in Indians

    Directory of Open Access Journals (Sweden)

    Bindu Appukuttan

    2014-01-01

    Full Text Available Aim: To provide the normative data of macular and retinal nerve fiber layer (RNFL thickness in Indians using spectral domain OCT (Spectralis OCT, Heidelberg Engineering, Germany and to evaluate the effects of age, gender, and refraction on these parameters. Design: Observational, cross-sectional study. Materials and Methods: The eyes of 105 healthy patients aged between 20-75 years, with no ocular disease and best corrected visual acuity of 20/20, were scanned using standard scanning protocols by a single examiner. Exclusion criteria included glaucoma, retinal diseases, diabetes, history of prior intraocular surgery or laser treatment. The mean macular and RNFL thickness were recorded, and the effects of age, gender, and refraction on these parameters were evaluated. This data was compared with published literature on Caucasians to assess the ethnic variations of these parameters. Results: The normal central foveal thickness in healthy Indian eyes measured using Spectralis OCT was 260.1 ± 18.19 ΅m. The nasal inner quadrant showed maximum retinal thickness (338.88 ± 18.17 ΅m.The mean RNFL thickness was 101.43 ± 8.63 ΅m with maximum thickness in the inferior quadrant. The central foveal thickness showed a gender-based difference (P = 0.005 but did not correlate significantly with age (P = 0.134, whereas the parafoveal, perifoveal thickness, macular volume, and RNFL thickness showed significant negative correlation with age. Conclusions: Our study provides the normative database for Indians on Spectralis OCT. It also suggests that age should be considered while interpreting the macular thickness and RNFL, whereas gender should also be given consideration in central foveal thickness.

  19. Lead Thickness Measurements

    International Nuclear Information System (INIS)

    Rucinski, R.

    1998-01-01

    The preshower lead thickness applied to the outside of D-Zero's superconducting solenoid vacuum shell was measured at the time of application. This engineering documents those thickness measurements. The lead was ordered in sheets 0.09375-inch and 0.0625-inch thick. The tolerance on thickness was specified to be +/- 0.003-inch. The sheets all were within that thickness tolerance. The nomenclature for each sheet was designated 1T, 1B, 2T, 2B where the numeral designates it's location in the wrap and 'T' or 'B' is short for 'top' or 'bottom' half of the solenoid. Micrometer measurements were taken at six locations around the perimeter of each sheet. The width,length, and weight of each piece was then measured. Using an assumed pure lead density of 0.40974 lb/in 3 , an average sheet thickness was calculated and compared to the perimeter thickness measurements. In every case, the calculated average thickness was a few mils thinner than the perimeter measurements. The ratio was constant, 0.98. This discrepancy is likely due to the assumed pure lead density. It is not felt that the perimeter is thicker than the center regions. The data suggests that the physical thickness of the sheets is uniform to +/- 0.0015-inch.

  20. Relationship between Outer Retinal Layers Thickness and Visual Acuity in Diabetic Macular Edema

    Directory of Open Access Journals (Sweden)

    Raymond L. M. Wong

    2015-01-01

    Full Text Available Purpose. To investigate the correlation of outer retinal layers (ORL thickness and visual acuity (VA in patients with diabetic macular edema (DME. Methods. Consecutive DME patients seen at the Retina Clinic of The University of Hong Kong were recruited for OCT assessment. The ORL thickness was defined as the distance between external limiting membrane (ELM and retinal pigment epithelium (RPE at the foveal center. The correlation between total retinal thickness, ORL thickness, and vision was calculated. Results. 78 patients with DME were recruited. The mean age was 58.1 years (±11.5 years and their mean visual acuity measured with Snellen chart was 0.51 (±0.18. The correlation coefficient between total retinal thickness and visual acuity was 0.34 (P < 0.001 whereas the correlation coefficient was 0.65 between ORL thickness and visual acuity (P < 0.001. Conclusion. ORL thickness correlates better with vision than the total retinal thickness. It is a novel OCT parameter in the assessment of DME. Moreover, it could be a potential long term visual prognostic factor for patients with DME.

  1. Normative data for macular thickness by high-definition spectral-domain optical coherence tomography (spectralis).

    Science.gov (United States)

    Grover, Sandeep; Murthy, Ravi K; Brar, Vikram S; Chalam, Kakarla V

    2009-08-01

    To establish normative data for the macular thickness by spectral-domain optical coherence tomography (SD-OCT) in subjects with no known retinal disease. Prospective, observational study in an academic institutional setting. Fifty subjects (age range, 20 to 84 years) with no known retinal disease, best-corrected visual acuity 20/20, and normal intraocular pressure were enrolled. The subjects were divided into 3 age groups: group 1 included subjects 20 to 40 years of age; group 2 included subjects 41 to 60 years of age; and group 3 included subjects 61 years of age and older. All subjects underwent a complete ophthalmologic examination to rule out any retinal diseases or glaucoma. All the OCT scans were performed by a single operator, and data obtained from the right eyes were analyzed by default, unless the right eye did not meet the inclusion criteria, and then data from left eyes were analyzed (n = 4). Central point thickness (CPT) and retinal thickness (RT) in 9 Early Treatment Diabetic Retinopathy Study (ETDRS) subfields, including central subfield (CSF), were analyzed. Statistical analyses were carried out using the analysis of variance. Overall, the mean CPT was 227.3 +/- 23.2 microm, and mean CSF was 270.2 +/- 22.5 microm. Among the ETDRS subfields, the outer nasal quadrant had the maximum thickness (mean +/- standard deviation, 339.5 +/- 16.9 microm). The RT did not show significant difference with age (P = .62) or with gender (P = .1). However, there was a suggestion of significant difference in RT of Black subjects as compared with White subjects (P = .007) in the present study. Normative values for macular thickness in otherwise healthy eyes were measured to be 227.3 microm (CPT) and 270.2 microm (CSF) using commercially available Spectralis SD-OCT. Based on the data, the present study proposes the guidelines for normal CSF thickness to be 315 microm for future studies using macular thickness measurements with Spectralis SD-OCT (Heidelberg Engineering

  2. Subfoveal choroidal thickness predicts macular atrophy in age-related macular degeneration: results from the TREX-AMD trial.

    Science.gov (United States)

    Fan, Wenying; Abdelfattah, Nizar Saleh; Uji, Akihito; Lei, Jianqin; Ip, Michael; Sadda, SriniVas R; Wykoff, Charles C

    2018-03-01

    Our purpose was to evaluate the relationship between subfoveal choroidal thickness (SCT) and development of macular atrophy (MA) in eyes with age-related macular degeneration (AMD). This was a prospective, multicenter study. Sixty participants (120 eyes) in the TREX-AMD trial (NCT01648292) with treatment-naïve neovascular AMD (NVAMD) in at least one eye were included. SCT was measured by certified reading center graders at baseline using spectral domain optical coherence tomography (SDOCT). The baseline SCT was correlated with the presence of MA at baseline and development of incident MA by month 18. Generalized estimating equations were used to account for information from both eyes. Baseline SCT in eyes with MA was statistically significantly less than in those without MA in both the dry AMD (DAMD) (P = 0.04) and NVAMD (P = 0.01) groups. Comparison of baseline SCT between MA developers and non-MA developers revealed a statistically significant difference (P = 0.03). Receiver operating characteristic curve (ROC) analysis showed the cut-off threshold of SCT for predicting the development of MA in cases without MA at baseline was 124 μm (AUC = 0.772; Sensitivity = 0.923; Specificity = 0.5). Among eyes without MA at baseline, those with baseline SCT ≤124 μm were 4.3 times more likely to develop MA (Odds ratio: 4.3, 95% confidence interval: 1.6-12, P = 0.005) than those with baseline SCT >124 μm. Eyes with AMD and MA had less SCT than those without MA. Eyes with less baseline SCT also appear to be at higher risk to develop MA within 18 months.

  3. Effect of serum cytokines and VEGF levels on diabetic retinopathy and macular thickness.

    Science.gov (United States)

    Ozturk, Banu Turgut; Bozkurt, Banu; Kerimoglu, Hurkan; Okka, Mehmet; Kamis, Umit; Gunduz, Kemal

    2009-09-19

    To investigate the role of serum inflammatory cytokines and vascular endothelial growth factor (VEGF) in diabetic retinopathy (DR) and evaluate their relationship with macular thickness measurements obtained with optical coherence tomography (OCT). The study enrolled 28 healthy subjects (Group 1), 31 patients without DR (Group 2), 49 patients with nonproliferative DR (Group 3), and 46 patients with proliferative DR (Group 4). Macular profile was assessed with Stratus OCT-3 and the serum concentrations of VEGF and interleukin-1 alpha (IL-1 alpha), interleukin-6 (IL-6), interleukin-8 (IL-8), interleukin-10 (IL-10), macrophage inflammatory protein (MIP-1 alpha), monocyte chemoattractant protein (MCP-1), and epidermal growth factor (EGF) were measured using multiplex bead immunoassay. The median value of the visual acuity was 20/20 (Groups 1 and 2), and 20/100 (Group 3), and 20/125 (Group 4). The median value of central subfield macular thickness was estimated as 165.50 microm in Group 1, 202.5 microm in Group 2, 318 microm in Group 3, and 310 microm in Group 4. The median serum VEGF level, which was 98.20 pg/ml in Group 1, demonstrated a progressive rise to 125.37 pg/ml in Group 2, to 153.07 pg/ml in Group 3, and to 149.12 pg/ml in Group 4. Statistical significance was found between all groups (p0.05). The median serum levels of IL-8, IL-10, MIP-1 alpha, and EGF revealed a wide range within each group, however, no statistically significant relationship was found between the groups (p>0.05). The median values of the serum MCP-1 concentrations presented a statistically significant rise with the progression of DR (p=0.02). No correlation was found between macular thickness and serum cytokine and VEGF levels (p>0.05). Increased serum levels of VEGF and MCP-1 may act as a key regulator of DR and provide a potential tool for risk assessment in diabetic patients. Further studies that evaluate both vitreous and serum levels in various stages of DR are needed to provide a

  4. Macular thickness and volume after uncomplicated phacoemulsification surgery evaluated by optical coherence tomography. A one-year follow-up.

    Science.gov (United States)

    Kecik, Dariusz; Makowiec-Tabernacka, Marta; Golebiewska, Joanna; Moneta-Wielgos, Joanna; Kasprzak, Jan

    2009-01-01

    To evaluate changes in the macular thickness and volume using optical coherence tomography in patients after phacoemulsification and intracapsular implantation of a foldable intraocular lens. The study included 82 patients (37 males and 45 females) after phacoemulsification and intracapsular implantaion of the same type of a foldable intraocular lens, without any other eye disease. Phacoemulsification was performed with an INFINITI machine. In all patients, macular thickness and volume were measured with an optical coherence tomograph (Stratus OCT) using the Fast Macular Thickness Map. The OCT evaluation was performed on days 1, 7, 30 and 90 postoperatively. In 58 patients (71%), it was additionally performed at 12 months after surgery and in 52 patients (63%) the macular parameters in the healthy and operated eyes were compared. A statistically significant increase in the minimal retinal thickness was observed on days 30 (p<0.0005) and 90 (p<0.005) postoperatively compared to post-operative day 1. A statistically significant increase in the foveal volume was seen on days 30 (p<0.00005) and 90 (p<0.0005). A statistically significant increase in the volume of the entire macula was found on days 7, 30 and 90 (p<0.00005). Uncomplicated cataract phacoemulsification is followed by increases in the central retinal thickness, foveal volume and volume of the entire macula on days 30 and 90 and at 12 months postoperatively. Further observation of patients is required to confirm whether the macular parameters will return to their values on day 1 postoperatively and if so, when this will occur.

  5. Macular and peripapillary retinal nerve fiber layer thickness in children with hyperopic anisometropic amblyopia

    Directory of Open Access Journals (Sweden)

    Shuang-Qing Wu

    2013-02-01

    Full Text Available AIM:To compare the retinal nerve fiber layer (RNFL thickness and macular thickness in the amblyopic eye with that in the sound eye of children with hyperopic anisometropic amblyopia using optical coherence tomography (OCT.METHODS: A prospective, nonrandom, intraindividual comparative cohort study includes 72 children with hyperopic anisometropic amblyopia in a single center. Macular thickness, macular foveola thickness, and peripapillary RNFL thickness were compared between the amblyopia eyes and the contralateral sound eyes.RESULTS:There were 38 male and 34 female patients, with a mean age as 9.7±1.9 years (range, 5–16 years. Hyperopic was +3.62±1.16D (range +2.00D to +6.50D in the amblyopic eyes, which was significantly higher in the control eyes with +0.76±0.90D (range 0D to +2.00D (P P = 0.02. The mean macular foveola thickness was significantly thicker in the amblyopic eyes than the contralateral sound eyes (181.4±14.2µm vs 175.2±13.3µm, P CONCLUSION:Eyes with hyperopic anisometropic amblyopia are found thicker macular foveola and peripapillary RNFL than the contralateral eyes in children.

  6. Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema.

    Science.gov (United States)

    Forooghian, Farzin; Cukras, Catherine; Meyerle, Catherine B; Chew, Emily Y; Wong, Wai T

    2008-10-01

    To evaluate macular thickness and volume measurements and their intrasession repeatability in two optical coherence tomography (OCT) systems: the Stratus OCT, a time domain system, and the Cirrus HD-OCT, a spectral domain system (both by Carl Zeiss Meditec, Inc., Dublin, CA), in the context of diabetic macular edema (DME). Thirty-three eyes of 33 diabetic patients with clinically significant macular edema (CSME) were scanned in a single session by a single operator on both OCT systems. Macular thickness measurements of nine standard macular subfields and total macular volume were obtained and analyzed. Bland-Altman plots were constructed to assess agreement in macular measurements. Intraclass correlation coefficients (ICCs), coefficients of repeatability (CR(W)), and coefficients of variation (CV(W)) were used to assess intrasession repeatability. Macular thickness in nine retinal subfields and macular volume were significantly higher in the Cirrus HD-OCT system compared with the Stratus OCT system. Subfield thickness and total volume measurements, respectively, were 30 to 55 microm and 3.2 mm(3) greater for the Cirrus HD-OCT system compared with the Stratus OCT system. Both Stratus OCT and Cirrus HD-OCT systems demonstrated high intrasession repeatability, with overlapping ranges for CR(W), CV(W), and ICC. Repeatability measures (CR(W) and CV(W)) differed significantly between systems in only one of nine subfields (outer temporal subfield). Absolute measures of macular thickness and volume in patients with DME differed significantly in magnitude between the Stratus OCT and Cirrus HD-OCT systems. However, both OCT systems demonstrated high intrasessional repeatability. Although the two systems may not be used interchangeably, they appear equally reliable in generating macular measurements for clinical practice and research.

  7. Macular Choroidal Thickness May Be the Earliest Determiner to Detect the Onset of Diabetic Retinopathy in Patients with Prediabetes: A Prospective and Comparative Study.

    Science.gov (United States)

    Yazgan, Serpil; Arpaci, Dilek; Celik, Haci Ugur; Dogan, Mustafa; Isık, Irem

    2017-07-01

    To evaluate the macular and peripapillary choroidal thickness and retinal volume in prediabetes. This prospective comparative study included 53 patients with prediabetes and 53 age- and sex-matched healthy subjects. Only right eyes were selected. Choroidal thicknesses (CT) and retinal volume were measured by optical coherence tomography. Macular CT was measured at the seven points including macular center, 1, 2, and 3 mm distances along the temporal and nasal scans. Peripapillary CT was measured at the eight points of the optic disk area. Systemic and laboratory findings of the subjects were also recorded. There were no significant differences in blood pressures, ocular findings including intraocular pressure, visual acuity, and refractive powers, and macular volumes between the two groups (p > 0.005). Macular and peripapillary CT at all measuring points, body mass index (BMI), fasting blood glucose (FBG), hemoglobinA1C, and lipid profile were significantly higher in prediabetic patients (p Prediabetic factors including impaired FBG, increased hemoglobinA1C, and BMI are independent risk factors for increase in choroidal thickness. Increased macular choroidal thickness may be the earliest determiner to detect the onset of diabetic retinopathy in prediabetes.

  8. Optical coherence tomography in retinitis pigmentosa: reproducibility and capacity to detect macular and retinal nerve fiber layer thickness alterations.

    Science.gov (United States)

    Garcia-Martin, Elena; Pinilla, Isabel; Sancho, Eva; Almarcegui, Carmen; Dolz, Isabel; Rodriguez-Mena, Diego; Fuertes, Isabel; Cuenca, Nicolas

    2012-09-01

    To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.

  9. Coating thickness measurement

    International Nuclear Information System (INIS)

    1976-12-01

    The standard specifies measurements of the coating thickness, which make use of beta backscattering and/or x-ray fluorescence. For commonly used combinations of coating material and base material the appropriate measuring ranges and radionuclides to be used are given for continuous as well as for discontinuous measurements

  10. Macular retinal ganglion cell-inner plexiform layer thickness in patients on hydroxychloroquine therapy.

    Science.gov (United States)

    Lee, Min Gyu; Kim, Sang Jin; Ham, Don-Il; Kang, Se Woong; Kee, Changwon; Lee, Jaejoon; Cha, Hoon-Suk; Koh, Eun-Mi

    2014-11-25

    We evaluated macular ganglion cell-inner plexiform layer (GC-IPL) thickness using spectral-domain optical coherence tomography (SD-OCT) in patients with chronic exposure to hydroxychloroquine (HCQ). This study included 130 subjects, who were divided into three groups: Group 1A, 55 patients with HCQ use ≥5 years; Group 1B, 46 patients with HCQ use 1000 g), significant correlations were not observed. This study revealed that macular GC-IPL thickness did not show definite correlations with HCQ use. However, some patients, especially with HCQ retinopathy or high cumulative doses, showed thin GC-IPL. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  11. Partial-thickness macular hole in vitreomacular traction syndrome: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Al Sabti Khalid

    2010-01-01

    Full Text Available Abstract Introduction Vitreomacular traction syndrome has recently been recognized as a distinct clinical condition. It may lead to many complications, such as cystoid macular edema, macular pucker formation, tractional macular detachment, and full-thickness macular hole formation. Case presentation We report a case of vitreomacular traction syndrome with eccentric traction at the macula and a partial-thickness macular hole in a 63-year-old Pakistani Punjabi man. The patient was evaluated using optical coherence tomography, and he underwent a successful pars plana vitrectomy. After the operation, his foveal contour regained normal configuration, and his visual acuity improved from 20/60 to 20/30. Conclusions Pars plana vitrectomy prevents the progression of a partial thickness macular hole in vitreomacular traction syndrome. The relief of traction by vitrectomy restores foveal anatomy and visual acuity in this condition.

  12. Relevance of Retinal Thickness Changes in the OCT Inner and Outer Rings to Predict Progression to Clinical Macular Edema

    DEFF Research Database (Denmark)

    Vujosevic, Stela; Varano, Monica; Egan, Catherine

    2015-01-01

    PURPOSE: To characterize the relevance of macular thickness changes in the inner and outer rings in the progression of macular edema in eyes/patients with diabetes type 2. METHODS: A total of 374 type 2 diabetic patients with mild nonproliferative diabetic retinopathy (ETDRS levels 20-35) were...... included in a 12-month prospective observational study to identify retinopathy progression. Retinal thickness analyses were performed in 194 eyes/patients using Cirrus SD- OCT and 166 eyes/patients using Spectralis SD-OCT. The DRCR.net classification of subclinical and clinical macular edema was used....... A composite grading of macular edema is proposed in this study. RESULTS: A total of 317 eyes/patients completed the study. SD-OCT identified clinical macular edema in 24 eyes/patients (6.7%) and subclinical macular edema in 104 eyes/patients (28.9%) at baseline. Increased thickness of the central subfield...

  13. Macular Choroidal Thickness in Myopic Eyes with and without a Dome-Shaped Macula: A Case-Control Study.

    Science.gov (United States)

    Soudier, Guillaume; Gaudric, Alain; Gualino, Vincent; Massin, Pascale; Nardin, Mathieu; Tadayoni, Ramin; Speeg-Schatz, Claude; Gaucher, David

    2016-01-01

    Dome-shaped macula (DSM) has recently been described with myopic staphyloma, which may cause decreased vision. The purpose of this study was to evaluate the choroidal thickness of eyes with and eyes without DSM. A total of 26 eyes with DSM were paired based on axial length with 26 eyes without DSM. All patients underwent spectral-domain OCT examination using the 7-line EDI (enhanced depth imaging) protocol. The mean choroidal thickness was measured using Early Treatment Diabetic Retinopathy Study (ETDRS) grid areas. Both nasal choroidal thickness and temporal choroidal thickness were significantly thinner in the DSM group (120.43 vs. 159.46 µm, p = 0.035, and 142.17 vs. 187.23 µm, p = 0.021, respectively). However, the mean central choroidal thickness did not differ (152.61 vs. 175.96 µm, p = 0.20). The ratio between central and peripheral choroidal thickness was very significantly elevated with DSM (1.18 ± 0.12 vs. 0.99 ± 0.09, p < 0.0001). Choroidal thickness decreases at the periphery but not in the macular area with DSM. DSM seems not to be due to an inward protrusion of the globe but due to macular anatomical preservation in a growing staphyloma. © 2016 S. Karger AG, Basel.

  14. Coating thickness measuring device

    International Nuclear Information System (INIS)

    Joffe, B.B.; Sawyer, B.E.; Spongr, J.J.

    1984-01-01

    A device especially adapted for measuring the thickness of coatings on small, complexly-shaped parts, such as, for example, electronic connectors, electronic contacts, or the like. The device includes a source of beta radiation and a radiation detector whereby backscatter of the radiation from the coated part can be detected and the thickness of the coating ascertained. The radiation source and detector are positioned in overlying relationship to the coated part and a microscope is provided to accurately position the device with respect to the part. Means are provided to control the rate of descent of the radiation source and radiation detector from its suspended position to its operating position and the resulting impact it makes with the coated part to thereby promote uniformity of readings from operator to operator, and also to avoid excessive impact with the part, thereby improving accuracy of measurement and eliminating damage to the parts

  15. Comparison of ketorolac 0.45% versus diclofenac 0.1% for macular thickness and volume after uncomplicated cataract surgery.

    Science.gov (United States)

    Lee, Tae Hee; Choi, Won; Ji, Yong Sok; Yoon, Kyung Chul

    2016-05-01

    To compare the effects of ketorolac 0.45% and diclofenac 0.1% on macular thickness and volume after uncomplicated cataract surgery. A total of 76 eyes of 76 patients who underwent uncomplicated cataract surgery were included. Patients were treated with either diclofenac 0.1% (38 eyes) or ketorolac 0.45% (38 eyes) after surgery. The macular thickness and volume were obtained with optical coherence tomography (OCT). Central subfield thickness (CST, OCT 1 mm zone), total foveal thickness (TFT, OCT 3 mm zone), total macular thickness (TMT, OCT 6 mm zone), average macular thickness (AMT) and total macular volume (TMV) were compared between the two study groups. No significant differences between groups were found in macular thickness or volume 1 month after cataract surgery. Two months after surgery, the ketorolac group had significantly lower CST, TFT, TMT and AMT than the diclofenac group (p diclofenac group. Following uncomplicated cataract surgery, topical ketorolac 0.45% was more effective than diclofenac 0.1% in preventing increases in macular thickness and volume. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. RETINA EXPANSION TECHNIQUE FOR MACULAR HOLE APPOSITION REPORT 2: Efficacy, Closure Rate, and Risks of a Macular Detachment Technique to Close Large Full-Thickness Macular Holes.

    Science.gov (United States)

    Wong, Roger; Howard, Catherine; Orobona, Giancarlo Dellʼaversana

    2018-04-01

    To describe the safety and efficacy of a technique to close large thickness macular holes. A consecutive retrospective interventional case series of 16 patients with macular holes greater than 650 microns in "aperture" diameter were included. The technique involves vitrectomy, followed by internal limiting membrane peeling. The macula is detached using subretinal injection of saline. Fluid-air exchange is performed to promote detachment and stretch of the retina. After this, the standard fluid-air exchange is performed and perfluoropropane gas is injected. Face-down posturing is advised. Adverse effects, preoperative, and postoperative visual acuities were recorded. Optical coherence tomography scans were also taken. The mean hole size was 739 microns (SD: 62 microns; mean base diameter: 1,311 microns). Eighty-three percent (14 of 16) of eyes had successful hole closure after the procedure. At 12-month follow-up, no worsening in visual acuity was reported, and improvement in visual acuity was noted in 14 of 16 eyes. No patients lost vision because of the procedure. It is possible to achieve anatomical closure of large macular holes using RETMA. No patients experienced visual loss. The level of visual improvement is likely limited because of the size and chronicity of these holes.

  17. Retinal oxygen saturation in relation to retinal thickness in diabetic macular edema

    DEFF Research Database (Denmark)

    Blindbæk, Søren Leer; Peto, Tunde; Grauslund, Jakob

    to retinal thickness in patients with diabetic macular edema (DME). Methods: We included 18 patients with DME that all had central retinal thickness (CRT) >300 µm and were free of active proliferative diabetic retinopathy. Optical coherence tomography (Topcon 3D OCT-2000 spectral domain OCT) was used...... for paracentral edema, the oxygen saturation in the upper and lower temporal arcade branches were compared to the corresponding upper and lower subfield thickness. Spearman’s rank was used to calculate correlation coefficients between CRT and retinal oximetry. Results: Median age and duration of diabetes was 59....... 92.3%, p=0.52). We found no correlation between CRT and retinal oxygen saturation, even when accounting for paracentral edema (p>0.05). Furthermore, there was no difference in retinal oxygen saturation between the macular hemisphere that was more or less affected by DME (p>0.05). Conclusion: Patients...

  18. Functional VEGF C-634G polymorphism is associated with development of diabetic macular edema and correlated with macular retinal thickness in type 2 diabetes

    International Nuclear Information System (INIS)

    Awata, Takuya; Kurihara, Susumu; Takata, Nobuki; Neda, Tamotsu; Iizuka, Hiroyuki; Ohkubo, Tomoko; Osaki, Masataka; Watanabe, Masaki; Nakashima, Youhei; Inukai, Kouichi; Inoue, Ikuo; Kawasaki, Izumi; Mori, Keisuke; Yoneya, Shin; Katayama, Shigehiro

    2005-01-01

    Since vascular endothelial growth factor (VEGF) has a strong effect on induction of vascular permeability, VEGF is an attractive candidate gene for development of diabetic macular edema (ME). Among the 378 patients with type 2 diabetes studied, 203 patients had no retinopathy, 93 had non-proliferative diabetic retinopathy (NPDR), and 82 had proliferative diabetic retinopathy (PDR). ME was present in 16 patients with NPDR and 47 patients with PDR. We genotyped three VEGF polymorphisms: C-2,578A, G-1,154A, and C-634G. Genotype and allele distribution of C-634G, but not C-2,578A or G-1,154A, were significantly different between patients with and without diabetic retinopathy. Logistic regression analysis revealed that the C-634G genotype was a risk factor for DR (p = 0.002), and furthermore for ME (p = 0.047), independently from severity of DR, with the -634C allele increasing the risk. Macular thickness measured by optical coherence tomography was correlated with the C-634G genotype, with the trend increasing with the presence of more -634C alleles (p = 0.006). Stepwise regression analysis showed that duration of diabetes and presence of the C-634G genotype were independent predictors of macular thickness. In addition, basic transcriptional activity levels associated with the -634C allele were greater compared to those seen with the -634G allele in human glioma and lymphoblastic T-lymphocyte cells. These results demonstrate that the VEGF C-634G polymorphism is a genetic risk factor for ME as well as DR

  19. THICKNESS OF THE MACULA, RETINAL NERVE FIBER LAYER, AND GANGLION CELL-INNER PLEXIFORM LAYER IN THE AGE-RELATED MACULAR DEGENERATION: The Repeatability Study of Spectral Domain Optical Coherence Tomography.

    Science.gov (United States)

    Shin, Il-Hwan; Lee, Woo-Hyuk; Lee, Jong-Joo; Jo, Young-Joon; Kim, Jung-Yeul

    2018-02-01

    To determine the repeatability of measuring the thickness of the central macula, retinal nerve fiber layer, and ganglion cell-inner plexiform layer (GC-IPL) using spectral domain optical coherence tomography (Cirrus HD-OCT) in eyes with age-related macular degeneration. One hundred and thirty-four eyes were included. The measurement repeatability was assessed by an experienced examiner who performed two consecutive measurements using a 512 × 128 macular cube scan and a 200 × 200 optic disk cube scan. To assess changes in macular morphology in patients with age-related macular degeneration, the patients were divided into the following three groups according to the central macular thickness (CMT): A group, CMT 300 μm. Measurement repeatability was assessed using test-retest variability, a coefficient of variation, and an intraclass correlation coefficient. The mean measurement repeatability for the central macular, retinal nerve fiber layer, and GC-IPL thickness was high in the B group. The mean measurement repeatability for both the central macula and retinal nerve fiber layer thickness was high in the A and C groups, but was lower for the GC-IPL thickness. The measurement repeatability for GC-IPL thickness was high in the B group, but low in the A group and in the C group. The automated measurement repeatability for GC-IPL thickness was significantly lower in patients with age-related macular degeneration with out of normal CMT range. The effect of changes in macular morphology should be considered when analyzing GC-IPL thicknesses in a variety of ocular diseases.

  20. Retinal layer location of increased retinal thickness in eyes with subclinical and clinical macular edema in diabetes type 2

    DEFF Research Database (Denmark)

    Bandello, Francesco; Tejerina, Amparo Navea; Vujosevic, Stela

    2015-01-01

    PURPOSE: To identify the retinal layer predominantly affected in eyes with subclinical and clinical macular edema in diabetes type 2. METHODS: A cohort of 194 type 2 diabetic eyes/patients with mild nonproliferative diabetic retinopathy (ETDRS levels 20/35) were examined with Cirrus spectral......-domain optical coherence tomography (OCT) at the baseline visit (ClinicalTrials.gov identifier: NCT01145599). Automated segmentation of the retinal layers of the eyes with subclinical and clinical macular edema was compared with a sample of 31 eyes from diabetic patients with normal OCT and an age......-matched control group of 58 healthy eyes. RESULTS: From the 194 eyes in the study, 62 had subclinical macular edema and 12 had clinical macular edema. The highest increases in retinal thickness (RT) were found in the inner nuclear layer (INL; 33.6% in subclinical macular edema and 81.8% in clinical macular edema...

  1. Surgical treatment and optical coherence tomographic evaluation for accidental laser-induced full-thickness macular holes.

    Science.gov (United States)

    Qi, Y; Wang, Y; You, Q; Tsai, F; Liu, W

    2017-07-01

    PurposeTo report OCT appearance and surgical outcomes of full-thickness macular holes (MHs) accidentally caused by laser devices.Patients and methodsThis retrospective case series included 11 eyes of 11 patients with laser-induced MHs treated by pars plana vitrectomy, internal limiting membrane (ILM) peeling, and gas or silicone oil tamponade. Evaluations included a full ophthalmic examination, macular spectral-domain optical coherence tomography (SD-OCT), and fundus photography. Main outcome measures is MH closure and final visual acuity; the secondary outcome was the changes of retinal pigment epithelium and photoreceptor layer evaluated by sequential post-operative SD-OCT images.ResultsFive patients were accidentally injured by a yttrium aluminum garnet (YAG) laser and six patients by handheld laser. MH diameters ranged from 272 to 815 μm (mean, 505.5±163.0 μm) preoperatively. Best-corrected visual acuity (BCVA) improved from a mean of 0.90 logMAR (range, counting finger-8/20) preoperatively to a mean of 0.34 logMAR (range, a counting finger-20/20) postoperatively (P=0.001, t=4.521). Seven of 11 patients (63.6%) achieved a BCVA better than 10/20. Ten patients had a subfoveal hyperreflectivity and four patients had a focal choroidal depression subfoveal preoperatively. At the last follow-up, all 11 eyes demonstrated the following: closure of the macular hole, variable degrees of disruption of external limiting membrane (ELM) and outer photoreceptor ellipsoid and interdigitation bands. In 10 eyes, the disruption was in the form of focal defects in the outer retina. After surgery, the subfoveal hyperreflectivity and focal choroidal depression remained.ConclusionAccidental laser-induced full-thickness macular holes can be successfully closed with surgery. Inadvertent retinal injury from laser devices, especially handheld laser injury has occurred with increasing frequency in recent years. However, there is a paucity of data regarding these types of injuries

  2. [Normal macular thickness and volume using spectral domain optical coherence tomography in a reference population].

    Science.gov (United States)

    Solé González, L; Abreu González, R; Alonso Plasencia, M; Abreu Reyes, P

    2013-09-01

    To establish normal values of macular thickness and volume obtained by the Cirrus SD-OCT (Carl ZeissMeditec, Dublin, CA, U.S.A.). Secondly, to assess the association between macular thickness and volume, sex and age. A prospective study was conducted on patients who were seen in a hospital Retina Unit, and who only had retinal disease in one eye. All the Macular Cube 512 × 128 scan protocols were performed by the same operator. Only the healthy eye was scanned in each patient. A total of 100 eyes of 100 patients were analysed. The mean central foveal thickness was 261.31 ± 17.67 microns, and was significantly (P<.05) higher in males (267.74 ± 16.98 microns) than in females (255.60 ± 16.40 microns). The mean obtained for the volume of the cube was 10.09 ± 0.37mm 3, and the mean thickness of 280.33 ± 10.34 cube um, with no statistically significant differences between gender being found (P<.05). The mean macular thickness is less at central level, increases in the inner perifoveal ring, and then decreases in the outer perifoveal ring. Furthermore, of all quadrants the greatest thickness was the nasal (328.27 ± 12.96 microns), followed by the upper (326.27 ± 11.89 microns), lower (322.53 ± 12.37mm) sectors, with the temporal sector being the thinnest (313.35 ± 14.20 microns). The mean age of the patients was 60.86 ± 14 years. The mean central foveal thickness and the thickness of the inner perifoveal ring are significantly higher in men than in women. Both the mean volume and thickness of the cube, as well as nasal and inner superior sectors decrease with age, being significantly only in women. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  3. Changes in Macular Retinal Layers and Peripapillary Nerve Fiber Layer Thickness after 577-nm Pattern Scanning Laser in Patients with Diabetic Retinopathy.

    Science.gov (United States)

    Shin, Ji Soo; Lee, Young Hoon

    2017-12-01

    The aim of this study was to evaluate the changes in thickness of each macular retinal layer, the peripapillary retinal nerve fiber layer (RNFL), and central macular thickness (CMT) after 577-nm pattern scanning laser (PASCAL) photocoagulation in patients with diabetic retinopathy. This retrospective study included 33 eyes with diabetic retinopathy that underwent 577-nm PASCAL photocoagulation. Each retinal layer thickness, peripapillary RNFL thickness, and CMT were measured by spectral-domain optical coherence tomography before 577-nm PASCAL photocoagulation, as well as at 1, 6, and 12 months after 577-nm PASCAL photocoagulation. Computerized intraretinal segmentation of optical coherence tomography was performed to identify the thickness of each retinal layer. The average thickness of the RNFL, ganglion cell layer, inner plexiform layer, inner nuclear layer, inner retinal layer, and CMT at each follow-up increased significantly from baseline (p 0.05). Each macular retinal layer and CMT had a tendency to increase for one year after 577-nm PASCAL photocoagulation, whereas the average thickness of retinal pigment epithelium decreased at one-year follow-up compared to the baseline. Although an increase in peripapillary RNFL thickness was observed one month after 577-nm PASCAL photocoagulation, there were no significant changes at the one-year follow-up compared to the baseline. © 2017 The Korean Ophthalmological Society

  4. Correlation of retinal nerve fibre layer and macular thickness with serum uric acid among type 2 diabetes mellitus.

    Science.gov (United States)

    Vinuthinee-Naidu, Munisamy-Naidu; Zunaina, Embong; Azreen-Redzal, Anuar; Nyi-Nyi, Naing

    2017-06-14

    Uric acid is a final breakdown product of purine catabolism in humans. It's a potent antioxidant and can also act as a pro-oxidant that induces oxidative stress on the vascular endothelial cells, thus mediating progression of diabetic related diseases. Various epidemiological and experimental evidence suggest that uric acid has a role in the etiology of type 2 diabetes mellitus. We conducted a cross-sectional study to evaluate the correlation of retinal nerve fibre layer (RNFL) and macular thickness with serum uric acid in type 2 diabetic patients. A cross-sectional study was conducted in the Eye Clinic, Hospital Universiti Sains Malaysia, Kelantan between the period of August 2013 till July 2015 involving type 2 diabetes mellitus patients with no diabetic retinopathy and with non-proliferative diabetic retinopathy (NPDR). An evaluation for RNFL and macular thickness was measured using Spectralis Heidelberg optical coherence tomography. Six ml of venous blood was taken for the measurement of serum uric acid and glycosylated haemoglobin (HbA1 C ). A total of 180 diabetic patients were recruited (90 patients with no diabetic retinopathy and 90 patients with NPDR) into the study. The mean level of serum uric acid for both the groups was within normal range and there was no significance difference between the two groups. Based on gender, both male and female gender showed significantly higher level of mean serum uric acid in no diabetic retinopathy group (p = 0.004 respectively). The mean serum uric acid was significantly higher in patient with HbA1 C  uric acid in both the groups. Serum uric acid showed a poor correlation with RNFL and macular thickness among type 2 diabetic patients.

  5. Influence of Clinical Factors and Magnification Correction on Normal Thickness Profiles of Macular Retinal Layers Using Optical Coherence Tomography

    Science.gov (United States)

    Higashide, Tomomi; Ohkubo, Shinji; Hangai, Masanori; Ito, Yasuki; Shimada, Noriaki; Ohno-Matsui, Kyoko; Terasaki, Hiroko; Sugiyama, Kazuhisa; Chew, Paul; Li, Kenneth K. W.; Yoshimura, Nagahisa

    2016-01-01

    Purpose To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. Methods The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular scans (RS-3000, NIDEK) in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters) with or without magnification correction. For each layer thickness, a semipartial correlation (sr) was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index. Results Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13) regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33) and a negative sr with GCLIPL (sr2, 0.22 to 0.31), GCC (sr2, 0.03 to 0.17), total retina (sr2, 0.07 to 0.17) and outer retina (sr2, 0.16 to 0.29) in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction. Conclusions The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction. PMID:26814541

  6. Influence of Clinical Factors and Magnification Correction on Normal Thickness Profiles of Macular Retinal Layers Using Optical Coherence Tomography.

    Directory of Open Access Journals (Sweden)

    Tomomi Higashide

    Full Text Available To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects.The thickness of retinal layers {retinal nerve fiber layer (RNFL, ganglion cell layer plus inner plexiform layer (GCLIPL, RNFL plus GCLIPL (ganglion cell complex, GCC, total retina, total retina minus GCC (outer retina} were measured by macular scans (RS-3000, NIDEK in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters with or without magnification correction. For each layer thickness, a semipartial correlation (sr was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index.Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13 regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33 and a negative sr with GCLIPL (sr2, 0.22 to 0.31, GCC (sr2, 0.03 to 0.17, total retina (sr2, 0.07 to 0.17 and outer retina (sr2, 0.16 to 0.29 in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction.The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction.

  7. Influence of Clinical Factors and Magnification Correction on Normal Thickness Profiles of Macular Retinal Layers Using Optical Coherence Tomography.

    Science.gov (United States)

    Higashide, Tomomi; Ohkubo, Shinji; Hangai, Masanori; Ito, Yasuki; Shimada, Noriaki; Ohno-Matsui, Kyoko; Terasaki, Hiroko; Sugiyama, Kazuhisa; Chew, Paul; Li, Kenneth K W; Yoshimura, Nagahisa

    2016-01-01

    To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular scans (RS-3000, NIDEK) in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters) with or without magnification correction. For each layer thickness, a semipartial correlation (sr) was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index. Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13) regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33) and a negative sr with GCLIPL (sr2, 0.22 to 0.31), GCC (sr2, 0.03 to 0.17), total retina (sr2, 0.07 to 0.17) and outer retina (sr2, 0.16 to 0.29) in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction. The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction.

  8. Impact of retinal pigment epithelium pathology on spectral-domain optical coherence tomography-derived macular thickness and volume metrics and their intersession repeatability.

    Science.gov (United States)

    Hanumunthadu, Daren; Wang, Jin Ping; Chen, Wei; Wong, Evan N; Chen, Yi; Morgan, William H; Patel, Praveen J; Chen, Fred K

    2017-04-01

    To determine the impact of retinal pigment epithelium (RPE) pathology on intersession repeatability of retinal thickness and volume metrics derived from Spectralis spectral-domain optical coherence tomography (Heidelberg Engineering, Heidelberg, Germany). Prospective cross-sectional single centre study. A total of 56 eyes of 56 subjects were divided into three groups: (i) normal RPE band (25 eyes); (ii) RPE elevation: macular soft drusen (13 eyes); and (iii) RPE attenuation: geographic atrophy or inherited retinal diseases (18 eyes). Each subject underwent three consecutive follow-up macular raster scans (61 B-scans at 119 μm separation) at 1-month intervals. Retinal thicknesses and volumes for each zone of the macular subfields before and after manual correction of segmentation error. Coefficients of repeatability (CR) were calculated. Mean (range) age was 57 (21-88) years. Mean central subfield thickness (CST) and total macular volume were 264 and 258 μm (P = 0.62), and 8.0 and 7.8 mm 3 (P = 0.31), before and after manual correction. Intersession CR (95% confidence interval) for CST and total macular volume were reduced from 40 (38-41) to 8.3 (8.1-8.5) and 0.62 to 0.16 mm 3 after manual correction of segmentation lines. CR for CST were 7.4, 23.5 and 66.7 μm before and 7.0, 10.9 and 7.6 μm after manual correction in groups i, ii and iii. Segmentation error in eyes with RPE disease has a significant impact on intersession repeatability of Spectralis spectral-domain optical coherence tomography macular thickness and volume metrics. Careful examination of each B-scan and manual adjustment can enhance the utility of quantitative measurement. Improved automated segmentation algorithms are needed. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  9. Comparative data on SD-OCT for the retinal nerve fiber layer and retinal macular thickness in a large cohort with Marfan syndrome.

    Science.gov (United States)

    Xu, WanWan; Kurup, Sudhi P; Fawzi, Amani A; Durbin, Mary K; Maumenee, Irene H; Mets, Marilyn B

    2017-01-01

    To report the distribution of macular and optic nerve topography in the eyes of individuals with Marfan syndrome aged 8-56 years using spectral domain optical coherence tomography (SD-OCT). Thirty-three patients with Marfan syndrome underwent a full eye examination including slit-lamp biomicroscopy, indirect ophthalmoscopy, and axial length measurement; and SD-OCT measurements of the retinal nerve fiber layer (RNFL) and macular thickness. For patients between the ages of 8 and 12 years, the average RNFL thickness is 98 ± 9 μm, the vertical cup to disc (C:D) ratio is 0.50 ± 0.10, the central subfield thickness (CST) is 274 ± 38 μm, and the macular volume is 10.3 ± 0.6 mm 3 . For patients between the ages of 13 and 17 years, the average RNFL is 86 ± 16 μm, the vertical C:D ratio is 0.35 ± 0.20, the CST is 259 ± 15 μm, and the macular volume is 10.1 ± 0.5 mm 3 . For patients 18 years or older, the average RNFL is 89 ± 12 μm, the vertical C:D ratio is 0.46 ± 0.18, the CST is 262 ± 20 μm, and the macular volume is 10.2 ± 0.4 mm 3 . When the average RNFL data are compared to a normative, age-adjusted database, 6 of 33 (18%) were thinner than the 5% limit. This study reports the distribution of SD-OCT data for patients with Marfan syndrome. Compared to a normative database, 18% of eyes with Marfan syndrome had RNFL thickness < 5% of the population.

  10. Decreased Thickness and Integrity of the Macular Elastic Layer of Bruch’s Membrane Correspond to the Distribution of Lesions Associated with Age-Related Macular Degeneration

    Science.gov (United States)

    Chong, N.H. Victor; Keonin, Jason; Luthert, Phil J.; Frennesson, Christina I.; Weingeist, David M.; Wolf, Rachel L.; Mullins, Robert F.; Hageman, Gregory S.

    2005-01-01

    Age-related macular degeneration (AMD) is a leading cause of blindness in the elderly. In its severest form, choroidal neovessels breach the macular Bruch’s membrane, an extracellular matrix compartment comprised of elastin and collagen laminae, and grow into the retina. We sought to determine whether structural properties of the elastic lamina (EL) correspond to the region of the macula that is predilected toward degeneration in AMD. Morphometric assessment of the macular and extramacular regions of 121 human donor eyes, with and without AMD, revealed a statistically significant difference in both the integrity (P macula than in the periphery. The integrity of the macular EL was significantly lower in donors with early-stage AMD (P = 0.028), active choroidal neovascularization (P = 0.020), and disciform scars (P = 0.003), as compared to unaffected, age-matched controls. EL thickness was significantly lower only in individuals with disciform scars (P = 0.008). The largest gaps in macular EL integrity were significantly larger in all categories of AMD (each P macula is more susceptible to degenerative events that occur in this disease. PMID:15632016

  11. Polycystic Ovary Syndrome: Aggressive or Protective Factor for the Retina? Evaluation of Macular Thickness and Retinal Nerve Fiber Layers Using High-Definition Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    José Edvan de Souza-Júnior

    2015-01-01

    Full Text Available Objective. To compare macular thickness (MT and retinal nerve fiber layers (RNFL between women with polycystic ovary syndrome (PCOS and healthy women. Materials and Methods. The study included 45 women with PCOS and 47 ovulatory women undergoing clinical-gynecological and ophthalmic evaluations, including measurement of MT, RNFL, and optic disc parameters using optical coherence tomography. Results. The superior RNFL around the optic nerve was significantly thicker in PCOS than in healthy volunteers (P=0.036. After stratification according to insulin resistance, the temporal inner macula (TIM, the inferior inner macula (IIM, the nasal inner macula (NIM, and the nasal outer macula (NOM were significantly thicker in PCOS group than in control group (P<0.05. Both the presence of obesity associated with insulin resistance (P=0.037 and glucose intolerance (P=0.001 were associated with significant increase in the PC1 mean score, relative to MT. A significant increase in the PC2 mean score occurred when considering the presence of metabolic syndrome (P<0.0001. There was a significant interaction between obesity and inflammation in a decreasing mean PC2 score relative to macular RNFL thickness (P=0.034. Conclusion. Decreased macular RNFL thickness and increased total MT are associated with metabolic abnormalities, while increased RNFL thickness around the optic nerve is associated with hormonal changes inherent in PCOS.

  12. Corneal thickness: measurement and implications.

    Science.gov (United States)

    Ehlers, Niels; Hjortdal, Jesper

    2004-03-01

    The thickness of the cornea was reported in more than 100-year-old textbooks on physiological optics (Helmholtz, Gullstrand). Physiological interest was revived in the 1950s by David Maurice, and over the next 50 years, this 'simple' biological parameter has been studied extensively. Several techniques for its measurement have been described and physiological and clinical significance have been studied. In this review, the different methods and techniques of measurement are briefly presented (optical, ultrasound). While the corneal thickness of many animals are the same over a considerable part of the surface, in the human cornea anterior and posterior curvature are not concentric giving rise to a problem of definition. Based on this the precision and accuracy of determining the central corneal thickness are discussed. Changes in corneal thickness reflects changes in function of the boundary layers, in particular the endothelial barrier. The absolute value of thickness is of importance for the estimation of IOP but also in diagnosis of corneal and systemic disorders. Finally it is discussed to what extent the thickness is a biometric parameter of significance, e.g. in the progression of myopia or in the development of retinal detachment.

  13. Retinal thickness after vitrectomy and internal limiting membrane peeling for macular hole and epiretinal membrane

    Science.gov (United States)

    Kumagai, Kazuyuki; Ogino, Nobuchika; Furukawa, Mariko; Hangai, Masanori; Kazama, Shigeyasu; Nishigaki, Shirou; Larson, Eric

    2012-01-01

    Purpose To determine the retinal thickness (RT), after vitrectomy with internal limiting membrane (ILM) peeling, for an idiopathic macular hole (MH) or an epiretinal membrane (ERM). Also, to investigate the effect of a dissociated optic nerve fiber layer (DONFL) appearance on RT. Methods A non-randomized, retrospective chart review was performed for 159 patients who had successful closure of a MH, with (n = 148), or without (n = 11), ILM peeling. Also studied were 117 patients who had successful removal of an ERM, with (n = 104), or without (n = 13), ILM peeling. The RT of the nine Early Treatment Diabetic Retinopathy Study areas was measured by spectral domain optical coherence tomography (SD-OCT). In the MH-with-ILM peeling and ERM-with-ILM peeling groups, the RT of the operated eyes was compared to the corresponding areas of normal fellow eyes. The inner temporal/inner nasal ratio (TNR) was used to assess the effect of ILM peeling on RT. The effects of DONFL appearance on RT were evaluated in only the MH-with-ILM peeling group. Results In the MH-with-ILM peeling group, the central, inner nasal, and outer nasal areas of the retina of operated eyes were significantly thicker than the corresponding areas of normal fellow eyes. In addition, the inner temporal, outer temporal, and inner superior retina was significantly thinner than in the corresponding areas of normal fellow eyes. Similar findings were observed regardless of the presence of a DONFL appearance. In the ERM-with-ILM peeling group, the retina of operated eyes was significantly thicker in all areas, except the inner and outer temporal areas. In the MH-with-ILM peeling group, the TNR was 0.86 in operated eyes, and 0.96 in fellow eyes (P peeling group, the TNR was 0.84 in operated eyes, and 0.95 in fellow eyes (P peeling group was 0.98, which was significantly greater than that of the MH-with-ILM peeling group (P peeling group was 0.98, which was significantly greater than that of ERM-with-ILM peeling

  14. Quantification of Macular Vascular Density Using Optical Coherence Tomography Angiography and Its Relationship with Retinal Thickness in Myopic Eyes of Young Adults

    Directory of Open Access Journals (Sweden)

    Shiqi Yang

    2017-01-01

    Full Text Available Purpose. To quantify macular vascular density using optical coherence tomography angiography (OCTA and to investigate its relationship with retinal thickness in myopic eyes of young adults. Methods. In this cross-sectional study, 268 myopic eyes without pathological changes were recruited and divided into three groups: mild myopia (n=81, moderate myopia (n=117, and high myopia (n=70. Macular vascular density was quantified by OCTA and compared among three groups. Average retinal thickness, central subfield thickness, and macular ganglion cell complex (mGCC thickness were also evaluated and compared. Correlations among these variables were analyzed. Results. There was no statistical difference in superficial (62.3 ± 5.7% versus 62.7 ± 5.9% versus 63.8 ± 5.5% and deep macular vascular densities (58.3 ± 9.6% versus 59.2 ± 9.3% versus 60.9 ± 7.9% among mild-myopia, moderate-myopia, and high-myopia groups (both P>0.05. Superficial and deep macular vascular densities both had correlations with mean arterial pressure. Furthermore, superficial macular vascular density was significantly correlated with mGCC thickness. Conclusions. Varying degrees of myopia did not affect macular vascular density in young healthy adults. In addition, superficial macular vascular density, as an independent factor, was positively correlated with mGCC thickness.

  15. Relationship between full-thickness macular hole and retinal break/lattice degeneration.

    Science.gov (United States)

    Zhang, Jinglin; Li, Yonghao; Zhao, Xiujuan; Cai, Yu; Yu, Xiling; Lu, Lin

    2015-12-01

    The purpose is to investigate the relationship between full-thickness macular hole (MH) and retinal break (RB) and/or lattice degeneration. Patients diagnosed as full-thickness MH and referred to Dr. Lin Lu from January 2009 to December 2013 were evaluated. All patients underwent general ophthalmologic examinations, fundus examination and optical coherence tomography (OCT). The RB and/or lattice degeneration were recorded. Totally 183 eyes of 167 patients were included. The sex ratio of men to women was 1:2.88. A total of 17 eyes were pseudophakic and 166 eyes were phakic. RB and/or lattice degeneration were found in 62 eyes (33.88%). The prevalence of RB and/or lattice degeneration was similar between men and women (P = 0.344 > 0.05). There was no statistical difference between the pseudophakic eyes and phakic eyes (P = 0.138 > 0.05). All of the RB and/or lattice degeneration were located near or anterior to the equator. The inferior quadrants and the vertical meridian were affected more often than the superior quadrants and the horizontal meridian. We identified a high incidence of RB/lattice degeneration in cases of full-thickness MH. Carefully examination of the peripheral retina and prophylactic treatment of RB and/or lattice degeneration are critical.

  16. Analysis of Macular and Retinal Nerve Fiber Layer Thickness in Children with Refractory Amblyopia after Femtosecond Laser-assisted Laser In situ Keratomileusis: A Retrospective Study.

    Science.gov (United States)

    Zhao, Peng-Fei; Zhou, Yue-Hua; Zhang, Jing; Wei, Wen-Bin

    2017-09-20

    Localized macular edema and retinal nerve fiber layer (RNFL) thinning have been reported shortly after laser in situ keratomileusis (LASIK) in adults. However, it is still unclear how LASIK affects the retina of children. This study aimed to investigate the macular retina and RNFL thickness in children with refractive amblyopia who underwent femtosecond laser-assisted LASIK (FS-LASIK). In this study, we included 56 eyes of 32 patients with refractive amblyopia who underwent FS-LASIK in our hospital from January 2012 to December 2016. Foveal (foveal center retinal, parafoveal retinal, and perifoveal), macular inner retinal (superior and inferior), and peripapillary RNFL thicknesses (superior, inferior, temporal, and nasal) were measured using Fourier-domain optical coherence tomography before surgery and 1 day, 3 days, and 1 week after surgery. We divided these patients into three groups based on their refractive error: High myopic group with 22 eyes (equivalent sphere, >6.00 D), mild myopic group with 19 eyes (equivalent sphere, 0-6.00 D), and hyperopic group with 15 eyes (equivalent sphere, >+0.50 D). We compared the macular retina and RNFL thickness before and after LASIK. A paired simple t-test was used for data analysis. One week after surgery, the visual acuity for all 56 eyes of the 32 patients reached their preoperative best-corrected vision. Visual acuity improved two lines or better for 31% of the patients. The residual refractive errors in 89% of the patients were within ±0.5 D. In the high myopic group, the foveal center retinal and parafoveal retinal thicknesses were thicker 1 day and 3 days after surgery than before surgery (t = 2.689, P = 0.012; t = 2.383, P = 0.018, respectively); no significant difference was found 1 week after surgery (P > 0.05). The foveal center retinal and parafoveal retinal thicknesses were greater 1 day after surgery than they were before surgery (P = 0.000 and P = 0.005, respectively) in the mild myopic and hyperopic groups

  17. Vitrectomy with internal limiting membrane peeling versus no peeling for idiopathic full-thickness macular hole.

    Science.gov (United States)

    Spiteri Cornish, Kurt; Lois, Noemi; Scott, Neil W; Burr, Jennifer; Cook, Jonathan; Boachie, Charles; Tadayoni, Ramin; la Cour, Morten; Christensen, Ulrik; Kwok, Alvin K H

    2014-03-01

    To determine whether internal limiting membrane (ILM) peeling improves anatomic and functional outcomes of full-thickness macular hole (FTMH) surgery when compared with the no-peeling technique. Systematic review and individual participant data (IPD) meta-analysis undertaken under the auspices of the Cochrane Eyes and Vision Group. Only randomized controlled trials (RCTs) were included. Patients with idiopathic stage 2, 3, and 4 FTMH undergoing vitrectomy with or without ILM peeling. Macular hole surgery, including vitrectomy and gas endotamponade with or without ILM peeling. Primary outcome was best-corrected distance visual acuity (BCdVA) at 6 months postoperatively. Secondary outcomes were BCdVA at 3 and 12 months; best-corrected near visual acuity (BCnVA) at 3, 6, and 12 months; primary (after a single surgery) and final (after >1 surgery) macular hole closure; need for additional surgical interventions; intraoperative and postoperative complications; patient-reported outcomes (PROs) (EuroQol-5D and Vision Function Questionnaire-25 scores at 6 months); and cost-effectiveness. Four RCTs were identified and included in the review. All RCTs were included in the meta-analysis; IPD were obtained from 3 of the 4 RCTs. No evidence of a difference in BCdVA at 6 months was detected (mean difference, -0.04; 95% confidence interval [CI], -0.12 to 0.03; P=0.27); however, there was evidence of a difference in BCdVA at 3 months favoring ILM peeling (mean difference, -0.09; 95% CI, -0.17 to-0.02; P=0.02). There was evidence of an effect favoring ILM peeling with regard to primary (odds ratio [OR], 9.27; 95% CI, 4.98-17.24; Ppeeling was found to be highly cost-effective. Available evidence supports ILM peeling as the treatment of choice for patients with idiopathic stage 2, 3, and 4 FTMH. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Accurate thickness measurement of graphene

    International Nuclear Information System (INIS)

    Shearer, Cameron J; Slattery, Ashley D; Stapleton, Andrew J; Shapter, Joseph G; Gibson, Christopher T

    2016-01-01

    Graphene has emerged as a material with a vast variety of applications. The electronic, optical and mechanical properties of graphene are strongly influenced by the number of layers present in a sample. As a result, the dimensional characterization of graphene films is crucial, especially with the continued development of new synthesis methods and applications. A number of techniques exist to determine the thickness of graphene films including optical contrast, Raman scattering and scanning probe microscopy techniques. Atomic force microscopy (AFM), in particular, is used extensively since it provides three-dimensional images that enable the measurement of the lateral dimensions of graphene films as well as the thickness, and by extension the number of layers present. However, in the literature AFM has proven to be inaccurate with a wide range of measured values for single layer graphene thickness reported (between 0.4 and 1.7 nm). This discrepancy has been attributed to tip-surface interactions, image feedback settings and surface chemistry. In this work, we use standard and carbon nanotube modified AFM probes and a relatively new AFM imaging mode known as PeakForce tapping mode to establish a protocol that will allow users to accurately determine the thickness of graphene films. In particular, the error in measuring the first layer is reduced from 0.1–1.3 nm to 0.1–0.3 nm. Furthermore, in the process we establish that the graphene-substrate adsorbate layer and imaging force, in particular the pressure the tip exerts on the surface, are crucial components in the accurate measurement of graphene using AFM. These findings can be applied to other 2D materials. (paper)

  19. Changes in visual function and thickness of macula after photodynamic therapy for age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Kyoko Okada

    2009-09-01

    Full Text Available Kyoko Okada, Mariko Kubota-Taniai, Masayasu Kitahashi, Takayuki Baba, Yoshinori Mitamura, Shuichi YamamotoDepartment of Ophthalmology and Visual Science, Chiba University Graduate School of Medicine, Chiba, JapanPurpose: To determine the correlation between the changes in the central retinal sensitivity and the changes in the foveal thickness (FT after photodynamic therapy (PDT for age-related macular degeneration (AMD.Methods: Nineteen eyes of 19 patients with choroidal neovasularizations (CNVs secondary to AMD were studied. The pretreatment values of the central retinal sensitivity determined by Micro Perimeter 1 (MP1; Nidek Technologies, best-corrected visual acuity (BCVA, and optical coherence tomography (OCT-determined FT were compared to the postoperative values at three and six months after PDT.Results: At six months, the retinal sensitivity within the central 10° was significantly improved (P = 0.02 and the FT was significantly thinner (P = 0.016. The BCVA, however, did not change significantly (P = 0.80. The changes in the retinal sensitivities were significantly correlated with the changes in the decrease in the FT (r = -0.59, P = 0.012 within the central 10° at six months after PDT.Conclusion: Significant improvements in retinal sensitivities within the central 10° and a decrease in FT were observed even though the BCVA was not significantly improved. The measurement of retinal sensitivity by MP1 may be a better method to assess central visual function than the conventional visual acuity after PDT.Keywords: age-related macular degeneration, fundus-related microperimetry, optical coherence tomography, photodynamic therapy

  20. Vitrectomy with internal limiting membrane (ILM) peeling versus vitrectomy with no peeling for idiopathic full-thickness macular hole (FTMH)

    DEFF Research Database (Denmark)

    Spiteri Cornish, Kurt; Lois, Noemi; Scott, Neil

    2013-01-01

    Several observational studies have suggested the potential benefit of internal limiting membrane (ILM) peeling to treat idiopathic full-thickness macular hole (FTMH). However, no strong evidence is available on the potential benefit(s) of this surgical manoeuvre and uncertainty remains among...... vitreoretinal surgeons about the indication for peeling the ILM, whether to use it in all cases or in long-standing and/or larger holes. ...

  1. Influence of uncomplicated phacoemulsification on central macular thickness in diabetic patients: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Jianping Liu

    Full Text Available To evaluate the effect of uncomplicated phacoemulsification on central macular thickness (CMT and best corrected visual acuity (BCVA in both diabetic patients without diabetic retinopathy (DR and diabetic patients with mild to moderate non-proliferative diabetic retinopathy (NPDR.Potential prospective observational studies were searched through PubMed and EMBASE. Standardized mean difference (SMD and 95% confidence interval (CI for changes in CMT and BCVA were evaluated at postoperative 1, 3 and 6 months. The pooled effect estimates were calculated in the use of a random-effects model.A total of 10 studies involving 190 eyes of diabetic patients without diabetic retinopathy and 143 eyes of diabetic patients with NPDR were identified. CMT values demonstrated a statistically significant increase after uncomplicated phacoemulsification at 1 month (SMD, -0.814; 95%CI, -1.230 to -0.399, 3 months (SMD, -0.565; 95%CI, -0.927 to -0.202 and 6 months (SMD, -0.458; 95%CI, -0.739 to -0.177 in diabetic patients with NPDR. There was no statistical difference in CMT values at postoperative 1 month (SMD, -1.206; 95%CI, -2.433 to 0.021and no statistically significant increase in CMT values at postoperative3 months (SMD, -0.535; 95%CI, -1.252 to 0.182 and 6 months (SMD, -1.181; 95%CI, -2.625 to 0.263 in diabetic patients without DR.BCVA was significantly increased at postoperative 1 month (SMD, 1.149; 95%CI, 0.251 to 2.047; and SMD,1.349; 95%CI, 0.264 to 2.434, respectively and 6 months (SMD, 1.295; 95%CI, 0.494 to 2.096; and SMD, 2.146; 95%CI, 0.172 to 4.120, respectively in both diabetic patients without DR and diabetic patients with NPDR. Sensitivity analysis showed that the results were relatively stable and reliable.Uncomplicated phacoemulsification in diabetic patients with mild to moderate NPDR seemed to influence significantly the subclinical thickening of the macular zones at postoperative 1, 3 and 6 months compared with diabetic patients without DR

  2. Analysis of macular and nerve fiber layer thickness in multiple sclerosis patients according to severity level and optic neuritis episodes.

    Science.gov (United States)

    Soler García, A; Padilla Parrado, F; Figueroa-Ortiz, L C; González Gómez, A; García-Ben, A; García-Ben, E; García-Campos, J M

    2016-01-01

    Quantitative assessment of macular and nerve fibre layer thickness in multiple sclerosis patients with regard to expanded disability status scale (EDSS) and presence or absence of previous optic neuritis episodes. We recruited 62 patients with multiple sclerosis (53 relapsing-remitting and 9 secondary progressive) and 12 disease-free controls. All patients underwent an ophthalmological examination, including quantitative analysis of the nerve fibre layer and macular thickness using optical coherence tomography. Patients were classified according to EDSS as A (lower than 1.5), B (between 1.5 and 3.5), and C (above 3.5). Mean nerve fibre layer thickness in control, A, B, and C groups was 103.35±12.62, 99.04±14.35, 93.59±15.41, and 87.36±18.75μm respectively, with statistically significant differences (P<.05). In patients with no history of optic neuritis, history of episodes in the last 3 to 6 months, or history longer than 6 months, mean nerve fibre layer thickness was 99.25±13.71, 93.92±13.30 and 80.07±15.91μm respectively; differences were significant (P<.05). Mean macular thickness in control, A, B, and C groups was 220.01±12.07, 217.78±20.02, 217.68±20.77, and 219.04±24.26μm respectively. Differences were not statistically significant. The mean retinal nerve fibre layer thickness in multiple sclerosis patients is related to the EDSS level. Patients with previous optic neuritis episodes have a thinner retinal nerve fibre layer than patients with no history of these episodes. Mean macular thickness is not correlated to EDSS level. Copyright © 2014 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Assessment of Choroidal Microstructure and Subfoveal Thickness Change in Eyes With Different Stages of Age-Related Macular Degeneration.

    Science.gov (United States)

    Lu, Linna; Xu, Shiqiong; He, Fangling; Liu, Yan; Zhang, Yidan; Wang, Jing; Wang, Zhiliang; Fan, Xianqun

    2016-03-01

    Age-related macular degeneration (AMD) is a major cause of irreversible blindness. Choroidal structural changes seem to be inevitable in AMD pathogenesis. Our study revealed associated choroidal microstructural changes in AMD eyes.The aim of the study was to compare choroidal microstructural changes in eyes with AMD of different stages.The study was a retrospective, cross-sectional case series.The participants comprised of 32 age-matched normal eyes as controls, and 26 fellow uninvolved eyes of intermediate/late AMD, 29 of early AMD, 28 of intermediate AMD, and 39 of late AMD.All subjects underwent comprehensive ophthalmologic examination. The choroid images, including subfoveal choroidal thickness, percentage of Sattler layer area, and en face images of the choroid, were obtained using spectral-domain optical coherence tomography.The main outcome measures were subfoveal choroidal thickness changes, percentage of Sattler layer area changes, and en face images of the choroid in AMD eyes.One hundred fifty-four eyes of 96 individuals with mean age of 67.1±9.2 years were included. The mean subfoveal choroidal thickness was 295.4 ± 56.8 μm in age-matched normal eyes, 306.7 ± 68.4 μm in fellow uninvolved eyes with AMD, 293.8 ± 80.4 μm in early AMD, 215.6 ± 80.4 μm in intermediate AMD, and 200.4 ± 66.6 μm in late AMD (F = 14.2, all P < 0.001). Choroidal thickness was greater in early AMD eyes than in intermediate/late AMD eyes (P < 0.001). Mean percentage of Sattler layer area in each group showed a similar tendency. Microstructure of the choroid showed reduced vascular density of Sattler layer areas in late AMD eyes compared with normal eyes.Decreasing subfoveal choroidal thickness and percentage of Sattler layer area were demonstrated in the progression of AMD. The choroidal change was related to atrophy of the microstructural changes of underlying capillaries and medium-sized vessels.

  4. Macular Ganglion Cell Inner Plexiform Layer Thickness in Glaucomatous Eyes with Localized Retinal Nerve Fiber Layer Defects.

    Directory of Open Access Journals (Sweden)

    Chunwei Zhang

    Full Text Available To investigate macular ganglion cell-inner plexiform layer (mGCIPL thickness in glaucomatous eyes with visible localized retinal nerve fiber layer (RNFL defects on stereophotographs.112 healthy and 149 glaucomatous eyes from the Diagnostic Innovations in Glaucoma Study (DIGS and the African Descent and Glaucoma Evaluation Study (ADAGES subjects had standard automated perimetry (SAP, optical coherence tomography (OCT imaging of the macula and optic nerve head, and stereoscopic optic disc photography. Masked observers identified localized RNFL defects by grading of stereophotographs.47 eyes had visible localized RNFL defects on stereophotographs. Eyes with visible localized RNFL defects had significantly thinner mGCIPL thickness compared to healthy eyes (68.3 ± 11.4 μm versus 79.2 ± 6.6 μm respectively, P<0.001 and similar mGCIPL thickness to glaucomatous eyes without localized RNFL defects (68.6 ± 11.2 μm, P = 1.000. The average mGCIPL thickness in eyes with RNFL defects was 14% less than similarly aged healthy controls. For 29 eyes with a visible RNFL defect in just one hemiretina (superior or inferior mGCIPL was thinnest in the same hemiretina in 26 eyes (90%. Eyes with inferior-temporal RNFL defects also had significantly thinner inferior-temporal mGCIPL (P<0.001 and inferior mGCIPL (P = 0.030 compared to glaucomatous eyes without a visible RNFL defect.The current study indicates that presence of a localized RNFL defect is likely to indicate significant macular damage, particularly in the region of the macular that topographically corresponds to the location of the RNFL defect.

  5. The Effect of LASIK Procedure on Peripapillary Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness in Myopic Eyes

    Directory of Open Access Journals (Sweden)

    Maja Zivkovic

    2017-01-01

    Full Text Available Purpose. To evaluate the effect of applied suction during microkeratome-assisted laser in situ keratomileusis (LASIK procedure on peripapillary retinal nerve fiber layer (RNFL thickness as well as macular ganglion cell-inner plexiform layer (GC-IPL thickness. Methods. 89 patients (124 eyes with established myopia range from −3.0 to −8.0 diopters and no associated ocular diseases were included in this study. RNFL and GC-IPL thickness measurements were performed by spectral domain optical coherence tomography (SD OCT one day before LASIK and at 1 and 6 months postoperatively. Results. Mean RNFL thickness prior to LASIK was 93.86±12.17 μm while the first month and the sixth month postoperatively were 94.01±12.04 μm and 94.46±12.27 μm, respectively. Comparing results, there is no significant difference between baseline, one month, and six months postoperatively for mean RNFL (p>0.05. Mean GC-IPL thickness was 81.70±7.47 μm preoperatively with no significant difference during the follow-up period (82.03±7.69 μm versus 81.84±7.64 μm; p>0.05. Conclusion. RNFL and GC-IPL complex thickness remained unaffected following LASIK intervention.

  6. Radiation transmission pipe thickness measurement system

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2010-01-01

    Fuji Electric Systems can be measured from the outer insulation of the transmission Characteristics and radiation detection equipment had been developed that can measure pipe wall thinning in plant and running, the recruitment of another three-beam calculation method by pipe thickness measurement system was developed to measure the thickness of the pipe side. This equipment has been possible to measure the thickness of the circumferential profile of the pipe attachment by adopting automatic rotation. (author)

  7. Clinical analysis of retinal nerve fiber layer thickness and macular fovea in hyperopia children with anisometropia amblyopia

    Directory of Open Access Journals (Sweden)

    Fei-Fei Li

    2017-10-01

    Full Text Available AIM:To analyze the clinical significance of axial length, diopter and retinal nerve fiber layer thickness in hyperopia children with anisometropia amblyopia. METHODS: From January 2015 to January 2017 in our hospital for treatment, 103 cases, all unilateral, were diagnosed as hyperopia anisometropia amblyopia. The eyes with amblyopia were as experimental group(103 eyes, another normal eye as control group(103 eyes. We took the detection with axial length, refraction, foveal thickness, corrected visual acuity, diopter and the average thickness of retinal nerve fiber layer. RESULTS: Differences in axial length and diopter and corrected visual acuity were statistically significant between the two groups(PP>0.05. There was statistical significance difference on the foveal thickness(PP>0.05. The positive correlation between diopter with nerve fiber layer thickness of foveal and around the optic disc were no statistically significant difference(P>0.05. CONCLUSION: Retinal thickness of the fovea in the eye with hyperopic anisometropia amblyopia were thicker than those in normal eyes; the nerve fiber layer of around the optic disc was not significantly different between the amblyopic eyes and contralateral eyes. The refraction and axial length had no significant correlation with optic nerve fiber layer and macular foveal thickness.

  8. Comparison of bromfenac 0.09% QD to nepafenac 0.1% TID after cataract surgery: pilot evaluation of visual acuity, macular volume, and retinal thickness at a single site

    Directory of Open Access Journals (Sweden)

    Cable M

    2012-07-01

    Full Text Available Melissa CableDiscover Vision Centers, Independence, MO, USAPurpose: The purpose of this study was to investigate the clinical outcomes of bromfenac ophthalmic solution 0.09% once daily (QD and nepafenac 0.1% ophthalmic suspension three times daily following cataract extraction with posterior chamber intraocular lens implantation, specifically looking at any differences in Early Treatment Diabetic Retinopathy Study visual acuities, macular volume, and/or retinal thickness changes.Methods: Subjects were randomly assigned to receive either bromfenac (n = 10 QD or nepafenac (n = 10 three times daily. Dosing began 3 days before cataract surgery, continuing to day 21 postsurgery. In addition to the investigated nonsteroidal antiinflammatory drug regimen, all subjects received antiinfective intraoperative and postoperative standard of care. Subjects were followed at 1 day and 1, 3, and 6 weeks postoperatively. Study visit assessments included best-corrected visual acuity, biomicroscopy, summed ocular inflammation score (anterior chamber cells and flare grading, intraocular pressure measurement, adverse event recording, and concomitant medication review. Optical coherence tomography was performed at 1, 3, and 6 weeks.Results: Both treatment groups had similar baseline measurements. Outcomes for mean letters read (P = 0.318, mean change in macular volume (P = 0.665, and retinal thickness (P = 0.552 were not statistically different between the groups from baseline through week six, although independently only the bromfenac group demonstrated a statistically significant improvement in letters gained from baseline to week six (P = 0.040. In the same time period, mean macular volume and retinal thickening worsened in the nepafenac group, demonstrating a statistically significant increase (P = 0.006 at week six for macular volume when compared to baseline. One subject in the nepafenac group experienced recurrent inflammation at week six, was unmasked, and

  9. Posterior pole asymmetry analysis and retinal thickness measurements in young relatives of glaucoma patients

    Directory of Open Access Journals (Sweden)

    Gökhan Pekel

    2015-08-01

    Full Text Available The presence of a family history of glaucoma is a known risk factor for primary open-angle glaucoma (POAG in middle-aged and older individuals. In this study, our aim was to demonstrate possible early glaucomatous alterations in young first- and second-degree relatives of POAG patients by spectral-domain optical coherence tomography. A total of 104 participants (52 relatives of POAG patients and 52 healthy individuals were recruited in this cross-sectional study. All the participants were between 17 years and 45 years of age. All eyes underwent testing with spectral-domain optical coherence tomography. Peripapillary retinal nerve fiber layer thickness, hemifield macular thickness, macular ganglion cell complex thickness, posterior pole asymmetry analysis, and retinal arteriolar caliber measurements were taken for comparison between the study and control groups. The mean peripapillary retinal nerve fiber layer thickness was 104.9 ± 8.8 μm in the study group and 105.6 ± 7.4 μm in the control group (p = 0.68. Although whole macular thickness measurements were higher in the control group when compared with the study group (p = 0.008, the macular ganglion cell complex thickness was similar in both groups (p = 0.87. The posterior pole asymmetry analysis revealed no statistically significant difference between the groups in the aspect of consecutive black squares (p = 0.79. The mean retinal arteriolar caliber was 85.9 ± 4.8 μm in the study group and 86.0 ± 5.0 μm in the control group (p = 0.90. In conclusion, young relatives of POAG patients do not show characteristic glaucomatous damage when compared with the controls.

  10. Comparison of intravitreal aflibercept and ranibizumab injections on subfoveal and peripapillary choroidal thickness in eyes with neovascular age-related macular degeneration.

    Science.gov (United States)

    Yun, Cheolmin; Oh, Jaeryung; Ahn, Jaemoon; Hwang, Soon-Young; Lee, Boram; Kim, Seong-Woo; Huh, Kuhl

    2016-09-01

    We aimed to compare changes in subfoveal and peripapillary choroidal thickness (CT) after intravitreal aflibercept or ranibizumab injections for neovascular age-related macular degeneration (AMD). Medical records of 54 treatment-naïve, consecutive patients (54 eyes) who were diagnosed with neovascular AMD and received three monthly injections of aflibercept (21 eyes) or ranibizumab (33 eyes) were reviewed. Subfoveal and peripapillary CT were measured with images obtained using spectral domain optical coherence tomography at baseline and at three months. Subfoveal CT decreased from 232.2 ± 94.4 μm at baseline to 207.1 ± 89.3 μm at three months in the aflibercept group (p macula as well.

  11. Clinical and cost-effectiveness of internal limiting membrane peeling for patients with idiopathic full thickness macular hole. Protocol for a Randomised Controlled Trial: FILMS (Full-thickness macular hole and Internal Limiting Membrane peeling Study

    Directory of Open Access Journals (Sweden)

    Cook Jonathan

    2008-11-01

    Full Text Available Abstract Background A full-thickness macular hole (FTMH is a common retinal condition associated with impaired vision. Randomised controlled trials (RCTs have demonstrated that surgery, by means of pars plana vitrectomy and post-operative intraocular tamponade with gas, is effective for stage 2, 3 and 4 FTMH. Internal limiting membrane (ILM peeling has been introduced as an additional surgical manoeuvre to increase the success of the surgery; i.e. increase rates of hole closure and visual improvement. However, little robust evidence exists supporting the superiority of ILM peeling compared with no-peeling techniques. The purpose of FILMS (Full-thickness macular hole and Internal Limiting Membrane peeling Study is to determine whether ILM peeling improves the visual function, the anatomical closure of FTMH, and the quality of life of patients affected by this disorder, and the cost-effectiveness of the surgery. Methods/Design Patients with stage 2–3 idiopathic FTMH of less or equal than 18 months duration (based on symptoms reported by the participant and with a visual acuity ≤ 20/40 in the study eye will be enrolled in this FILMS from eight sites across the UK and Ireland. Participants will be randomised to receive combined cataract surgery (phacoemulsification and intraocular lens implantation and pars plana vitrectomy with postoperative intraocular tamponade with gas, with or without ILM peeling. The primary outcome is distance visual acuity at 6 months. Secondary outcomes include distance visual acuity at 3 and 24 months, near visual acuity at 3, 6, and 24 months, contrast sensitivity at 6 months, reading speed at 6 months, anatomical closure of the macular hole at each time point (1, 3, 6, and 24 months, health related quality of life (HRQOL at six months, costs to the health service and the participant, incremental costs per quality adjusted life year (QALY and adverse events. Discussion FILMS will provide high quality evidence on the

  12. Size of the Optic Nerve Head and Its Relationship with the Thickness of the Macular Ganglion Cell Complex and Peripapillary Retinal Nerve Fiber Layer in Patients with Primary Open Angle Glaucoma

    Directory of Open Access Journals (Sweden)

    Nobuko Enomoto

    2015-01-01

    Full Text Available Purpose. To evaluate the relationships among the optic nerve head (ONH area, macular ganglion cell complex (mGCC thickness, circumpapillary retinal nerve fiber layer (cpRNFL thickness, and visual field defects in patients with primary open angle glaucoma (POAG. Methods. This retrospective study included 90 eyes of 90 patients with POAG. The ONH area, rim area, mGCC thickness, and cpRNFL thickness were measured using optical coherence tomography. Mean deviation (MD was measured using standard automated perimetry. The relationships among clinical factors including age, refraction, the ONH area, the rim area, the mGCC thickness, the cpRNFL thickness, and MD were evaluated using correlation coefficients and multiple regression analyses. Results. The significant correlation of the ONH area with refraction (r=0.362, P<0.001, the mGCC thickness (r=0.225, P=0.033, and the cpRNFL thickness (r=0.253, P=0.016 was found. Multiple regression analysis showed that the ONH area, rim area, and MD were selected as significant contributing factors to explain the mGCC thickness and cpRNFL thickness. No factor was selected to explain MD. Conclusions. The ONH area, in other words, the disc size itself may affect the mGCC thickness and cpRNFL thickness in POAG patients.

  13. Card controlled beta backscatter thickness measuring instrument

    International Nuclear Information System (INIS)

    Schlesinger, J.

    1978-01-01

    An improved beta backscatter instrument for the nondestructive measurement of the thickness of thin coatings on a substrate is described. Included therein is the utilization of a bank of memory stored data representative of isotope, substrate, coating material and thickness range characteristics in association with a control card having predetermined indicia thereon selectively representative of a particular isotope, substrate material, coating material and thickness range for conditioning electronic circuit means by memory stored data selected in accord with the predetermined indicia on a control card for converting backscattered beta particle counts into indicia of coating thickness

  14. REPRODUCIBILITY OF MACULAR PIGMENT OPTICAL DENSITY MEASUREMENT BY TWO-WAVELENGTH AUTOFLUORESCENCE IN A CLINICAL SETTING.

    Science.gov (United States)

    You, Qi Sheng; Bartsch, Dirk-Uwe G; Espina, Mark; Alam, Mostafa; Camacho, Natalia; Mendoza, Nadia; Freeman, William R

    2016-07-01

    Macular pigment, composed of lutein, zeaxanthin, and meso-zeaxanthin, is postulated to protect against age-related macular degeneration, likely because of filtering blue light and its antioxidant properties. Macular pigment optical density (MPOD) is reported to be associated with macular function evaluated by visual acuity and multifocal electroretinogram. Given the importance of macular pigment, reliable and accurate measurement methods are important. The main purpose of this study is to determine the reproducibility of MPOD measurement by two-wavelength autofluorescence method using scanning laser ophthalmoscopy. Sixty-eight eyes of 39 persons were enrolled in the study, including 11 normal eyes, 16 eyes with wet age-related macular degeneration, 16 eyes with dry age-related macular degeneration, 11 eyes with macular edema due to diabetic mellitus, branch retinal vein occlusion or macular telangiectasia, and 14 eyes with tractional maculopathy, including vitreomacular traction, epiretinal membrane, or macular hole. MPOD was measured with a two-wavelength (488 and 514 nm) autofluorescence method with the Spectralis HRA + OCT after pupil dilation. The measurement was repeated for each eye 10 minutes later. The analysis of variance and Bland-Altman plot were used to assess the reproducibility between the two measurements. The mean MPOD at eccentricities of 1° and 2° was 0.36 ± 0.17 (range: 0.04-0.69) and 0.15 ± 0.08 (range: -0.03 to 0.35) for the first measurement and 0.35 ± 0.17 (range: 0.02-0.68) and 0.15 ± 0.08 (range: -0.01 to 0.33) for the second measurement, respectively. The difference between the 2 measurements was not statistically significant, and the Bland-Altman plot showed 7.4% and 5.9% points outside the 95% limits of agreement, indicating an overall excellent reproducibility. Similarly, there is no significant difference between the first and second measurements of MPOD volume within eccentricities of 1°, 2°, and 6° radius, and the Bland

  15. Impacts of age and sex on retinal layer thicknesses measured by spectral domain optical coherence tomography with Spectralis.

    Science.gov (United States)

    Nieves-Moreno, María; Martínez-de-la-Casa, José M; Morales-Fernández, Laura; Sánchez-Jean, Rubén; Sáenz-Francés, Federico; García-Feijoó, Julián

    2018-01-01

    To examine differences in individual retinal layer thicknesses measured by spectral domain optical coherence tomography (SD-OCT) (Spectralis®) produced with age and according to sex. Cross-sectional, observational study. The study was conducted in 297 eyes of 297 healthy subjects aged 18 to 87 years. In one randomly selected eye of each participant the volume and mean thicknesses of the different macular layers were measured by SD-OCT using the instrument's macular segmentation software. Volume and mean thickness of macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), retinal pigmentary epithelium (RPE) and photoreceptor layer (PR). Retinal thickness was reduced by 0.24 μm for every one year of age. Age adjusted linear regression analysis revealed mean GCL, IPL, ONL and PR thickness reductions and a mean OPL thickness increase with age. Women had significantly lower mean GCL, IPL, INL, ONL and PR thicknesses and volumes and a significantly greater mRNFL volume than men. The thickness of most retinal layers varies both with age and according to sex. Longitudinal studies are needed to determine the rate of layer thinning produced with age.

  16. Model SH intelligent instrument for thickness measuring

    International Nuclear Information System (INIS)

    Liu Juntao; Jia Weizhuang; Zhao Yunlong

    1995-01-01

    The authors introduce Model SH Intelligent Instrument for thickness measuring by using principle of beta back-scattering and its application range, features, principle of operation, system design, calibration and specifications

  17. Greenland Radar Ice Sheet Thickness Measurements

    Data.gov (United States)

    National Aeronautics and Space Administration — Two 150-MHz coherent radar depth sounders were developed and flown over the Greenland ice sheet to obtain ice thickness measurements in support of PARCA...

  18. Non-invasive in vivo measurement of macular carotenoids

    Science.gov (United States)

    Lambert, James L. (Inventor); Borchert, Mark S. (Inventor)

    2009-01-01

    A non-invasive in vivo method for assessing macular carotenoids includes performing Optical Coherence Tomography (OCT) on a retina of a subject. A spatial representation of carotenoid levels in the macula based on data from the OCT of the retina can be generated.

  19. Vitrectomy with internal limiting membrane (ILM) peeling versus vitrectomy with no peeling for idiopathic full-thickness macular hole (FTMH).

    Science.gov (United States)

    Spiteri Cornish, Kurt; Lois, Noemi; Scott, Neil; Burr, Jennifer; Cook, Jonathan; Boachie, Charles; Tadayoni, Ramin; la Cour, Morten; Christensen, Ulrik; Kwok, Alvin

    2013-06-05

    Several observational studies have suggested the potential benefit of internal limiting membrane (ILM) peeling to treat idiopathic full-thickness macular hole (FTMH). However, no strong evidence is available on the potential benefit(s) of this surgical manoeuvre and uncertainty remains among vitreoretinal surgeons about the indication for peeling the ILM, whether to use it in all cases or in long-standing and/or larger holes.  To determine whether ILM peeling improves anatomical and functional outcomes of macular hole surgery compared with the no-peeling technique and to investigate the impact of different parameters such as presenting vision, stage/size of the hole and duration of symptoms in the success of the surgery. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) which contains the Cochrane Eyes and Vision Group Trials Register (The Cochrane Library 2013, Issue 2), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE, (January 1950 to February 2013), EMBASE (January 1980 to February 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to February 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We searched the reference lists of included studies for any additional studies not identified by the electronic searches. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 28 February 2013.We searched reference lists of the studies included in the review for information about other studies on ILM peeling in macular hole surgery. We searched Proceedings for the following conferences up to February 2013: American Academy of Ophthalmology (AAO), Annual Meeting of the American Society of Retina Specialists

  20. Uncertainty estimation of ultrasonic thickness measurement

    International Nuclear Information System (INIS)

    Yassir Yassen, Abdul Razak Daud; Mohammad Pauzi Ismail; Abdul Aziz Jemain

    2009-01-01

    The most important factor that should be taken into consideration when selecting ultrasonic thickness measurement technique is its reliability. Only when the uncertainty of a measurement results is known, it may be judged if the result is adequate for intended purpose. The objective of this study is to model the ultrasonic thickness measurement function, to identify the most contributing input uncertainty components, and to estimate the uncertainty of the ultrasonic thickness measurement results. We assumed that there are five error sources significantly contribute to the final error, these sources are calibration velocity, transit time, zero offset, measurement repeatability and resolution, by applying the propagation of uncertainty law to the model function, a combined uncertainty of the ultrasonic thickness measurement was obtained. In this study the modeling function of ultrasonic thickness measurement was derived. By using this model the estimation of the uncertainty of the final output result was found to be reliable. It was also found that the most contributing input uncertainty components are calibration velocity, transit time linearity and zero offset. (author)

  1. Individual Test Point Fluctuations of Macular Sensitivity in Healthy Eyes and Eyes With Age-Related Macular Degeneration Measured With Microperimetry.

    Science.gov (United States)

    Barboni, Mirella Telles Salgueiro; Szepessy, Zsuzsanna; Ventura, Dora Fix; Németh, János

    2018-04-01

    To establish fluctuation limits, it was considered that not only overall macular sensitivity but also fluctuations of individual test points in the macula might have clinical value. Three repeated measurements of microperimetry were performed using the Standard Expert test of Macular Integrity Assessment (MAIA) in healthy subjects ( N = 12, age = 23.8 ± 1.5 years old) and in patients with age-related macular degeneration (AMD) ( N = 11, age = 68.5 ± 7.4 years old). A total of 37 macular points arranged in four concentric rings and in four quadrants were analyzed individually and in groups. The data show low fluctuation of macular sensitivity of individual test points in healthy subjects (average = 1.38 ± 0.28 dB) and AMD patients (average = 2.12 ± 0.60 dB). Lower sensitivity points are more related to higher fluctuation than to the distance from the central point. Fixation stability showed no effect on the sensitivity fluctuation. The 95th percentile of the standard deviations of healthy subjects was, on average, 2.7 dB, ranging from 1.2 to 4 dB, depending on the point tested. Point analysis and regional analysis might be considered prior to evaluating macular sensitivity fluctuation in order to distinguish between normal variation and a clinical change. S tatistical methods were used to compare repeated microperimetry measurements and to establish fluctuation limits of the macular sensitivity. This analysis could add information regarding the integrity of different macular areas and provide new insights into fixation points prior to the biofeedback fixation training.

  2. Glue Film Thickness Measurements by Spectral Reflectance

    International Nuclear Information System (INIS)

    Marshall, B.R.

    2010-01-01

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 (micro)m, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  3. Glue Film Thickness Measurements by Spectral Reflectance

    Energy Technology Data Exchange (ETDEWEB)

    B. R. Marshall

    2010-09-20

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 μm, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  4. Rapid Measurement of Nanoparticle Thickness Profiles

    International Nuclear Information System (INIS)

    Katz-Boon, Hadas; Rossouw, Chris J.; Dwyer, Christian; Etheridge, Joanne

    2013-01-01

    A method to measure the thickness of a single-crystal nanoparticle in the direction parallel to the incident beam from annular dark field scanning transmission electron microscope (ADF-STEM) images is reported, providing a map of thickness versus position across the nanoparticle—a ‘thickness profile’ image. The method is rapid and hence suitable for surveying large numbers of nanoparticles. The method measures the intensity scattered to a characterised ADF detector and compares this to the incident beam intensity, to obtain a normalized ADF image. The normalised intensity is then converted to thickness via dynamical ADF image simulations. The method is accurate within 10% and the precision is dominated primarily by ‘shot noise’. Merits and limitations of this method are discussed. A method to calibrate the response function of the ADF detector without external equipment is also described, which is applicable to the entire range of gain and background settings. -- Highlights: ► A method is developed to convert ADF-STEM images to ‘thickness profile’ images. ► It is applicable in particles survey, facets determination and discrete tomography. ► A method to calibrate the response of the ADF detector is described. ► The response in analysed across a range of conditions. ► Dynamical ADF image simulations are presented, demonstrating intensity vs. thickness dependence.

  5. MACULAR CHOROIDAL VOLUME CHANGES AFTER INTRAVITREAL BEVACIZUMAB FOR EXUDATIVE AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    Palkovits, Stefan; Seidel, Gerald; Pertl, Laura; Malle, Eva M; Hausberger, Silke; Makk, Johanna; Singer, Christoph; Osterholt, Julia; Herzog, Sereina A; Haas, Anton; Weger, Martin

    2017-12-01

    To evaluate the effect of intravitreal bevacizumab on the macular choroidal volume and the subfoveal choroidal thickness in treatment naïve eyes with exudative age-related macular degeneration. The macular choroidal volume and the subfoveal choroidal thickness were measured using enhanced depth imaging optical coherence tomography. After a screening examination, each patient received 3 monthly intravitreal injections of 1.25 mg bevacizumab. One month after the third injection was a final assessment. Forty-seven patients with a mean age of 80 ± 6.4 years were included. The macular choroidal volume decreased significantly from median 4.1 mm (interquartile range 3.4-5.9) to median 3.9 mm (interquartile range 3.1-5.6) between the baseline and final examination (difference -0.46 mm, 95% confidence interval: -0.57 to 0.35, P macular choroidal volume at baseline and subfoveal choroidal thickness at baseline were not associated with the response to treatment. The macular choroidal volume and the subfoveal choroidal thickness decreased significantly after 3 monthly bevacizumab injections for exudative age-related macular degeneration.

  6. Retinal thickness assessed by optical coherence tomography (OCT in pseudophakic macular edema Espessura retiniana medida pela tomografia de coerência óptica (OCT no edema macular do pseudofácico

    Directory of Open Access Journals (Sweden)

    Maria Teresa Brizzi Chizzoti Bonanomi

    2006-08-01

    Full Text Available PURPOSE: To evaluate the usefulness of the optical coherence tomography (OCT retinal map in angiographic pseudophakic macular edema (ACME. METHODS: This is a prospective analysis of a group of 36 pseudophakic eyes at the fifth postoperative week, submitted to optical coherence tomography 2 macular map and fluorescein angiography on the same day and, a control group of twenty-two 20/20 vision eyes with a minimum 6-month postoperative period, submitted to optical coherence tomography 2 macular map only. Exclusion criteria were diabetes, any macular pathology and unreadable optical coherence tomography or angiogram. The angiograms were divided into three groups according to the edema intensity: Group I: level 0 (absence of angiographic pseudophakic macular edema; group II: levels 1 and 2 (incomplete and complete perifoveal angiographic pseudophakic macular edema respectively and group III: levels 3 and 4 (up to one disc diameter and greater than one disc diameter angiographic pseudophakic macular edema area respectively. The nine zones of the optical coherence tomography macular map were compared between the control and the three subgroups of the study group and, between group I and groups II and III. RESULTS: Among the 36 eyes, 23 (64% were classified as group I, 10 (28% as group II and three (8% as group III. The mean thickness of the fovea zone was 185±15 µm for the control group, 189±24 µm for group I, 213±33 µm for group II and 455±38 µm for group III. Significant differences: between group III and the control or group I for all zones (pOBJETIVO: Medir a espessura retiniana pela tomografia de coerência óptica (OCT no edema macular angiográfico do pseudofácico (ACME. MÉTODOS: Trabalho prospectivo composto de um grupo de estudo com 36 olhos pseudofácicos, entre a 4ª e a 6ª semana de pós-operatório, submetidos ao mapa macular com a tomografia de coerência óptica 2 e à angiofluoresceinografia no mesmo dia e, um grupo controle

  7. The Case Mix of Patients Presenting with Full-Thickness Macular Holes and Progression before Surgery: Implications for Optimum Management.

    Science.gov (United States)

    Madi, Haifa A; Dinah, Christiana; Rees, Jon; Steel, David H W

    2015-01-01

    Analysis of pre-operative spectral domain optical coherence tomography (SD-OCT) characteristics of full-thickness macular holes (FTMH) and effect on optimum management. We retrospectively reviewed SD-OCT characteristics of a consecutive cohort of patients waitlisted for FTMH surgery and categorized them by current evidence-based treatments. Out of the 106 holes analysed, 36 were small, 40 medium and 30 large. Initially, 33 holes had vitreomacular adhesion (VMA). 41 holes were analysed for change in characteristics with a median duration of 8 weeks between the scans. The number of small or medium holes decreased from 20 to 6 and that of large holes doubled. The number of holes with VMA halved. Smaller hole size (p = 0.014) and being phakic (p = 0.048) were associated with a larger increase in size. The strongest predictor of hole progression into a different surgical management category was the presence of VMA. FTMH characteristics can change significantly pre-operatively and affect optimal treatment choice.

  8. Study on the ionization chamber for thickness measurement

    International Nuclear Information System (INIS)

    Xue Shili; Miao Qiangwen

    1988-01-01

    The principle, construction and performances of ionization chambers for measuring the thickness of metal and nonmetal materials are introduced. With them the thickness of thin materials (thickness ranging from 10 to 6000 g/m 2 ), the surface layer thickness of composed materials and the thickness of steel plate (thickness ranging from 0 to 32 kg/m 2 ) are measured effectively

  9. Normative Database and Color-code Agreement of Peripapillary Retinal Nerve Fiber Layer and Macular Ganglion Cell-inner Plexiform Layer Thickness in a Vietnamese Population.

    Science.gov (United States)

    Perez, Claudio I; Chansangpetch, Sunee; Thai, Andy; Nguyen, Anh-Hien; Nguyen, Anwell; Mora, Marta; Nguyen, Ngoc; Lin, Shan C

    2018-06-05

    Evaluate the distribution and the color probability codes of the peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell-inner plexiform layer (GCIPL) thickness in a healthy Vietnamese population and compare them with the original color-codes provided by the Cirrus spectral domain OCT. Cross-sectional study. We recruited non-glaucomatous Vietnamese subjects and constructed a normative database for peripapillary RNFL and macular GCIPL thickness. The probability color-codes for each decade of age were calculated. We evaluated the agreement with Kappa coefficient (κ) between OCT color probability codes with Cirrus built-in original normative database and the Vietnamese normative database. 149 eyes of 149 subjects were included. The mean age of enrollees was 60.77 (±11.09) years, with a mean spherical equivalent of +0.65 (±1.58) D and mean axial length of 23.4 (±0.87) mm. Average RNFL thickness was 97.86 (±9.19) microns and average macular GCIPL was 82.49 (±6.09) microns. Agreement between original and adjusted normative database for RNFL was fair for average and inferior quadrant (κ=0.25 and 0.2, respectively); and good for other quadrants (range: κ=0.63-0.73). For macular GCIPL κ agreement ranged between 0.39 and 0.69. After adjusting with the normative Vietnamese database, the percent of yellow and red color-codes increased significantly for peripapillary RNFL thickness. Vietnamese population has a thicker RNFL in comparison with Cirrus normative database. This leads to a poor color-code agreement in average and inferior quadrant between the original and adjusted database. These findings should encourage to create a peripapillary RNFL normative database for each ethnicity.

  10. Precision of hyaline cartilage thickness measurements

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, K.; Buckwalter, K.; Helvie, M.; Niklason, L.; Martel, W. (Univ. of Michigan Hospitals, Ann Arbor, MI (United States). Dept. of Radiology)

    1992-05-01

    Measurement of cartilage thickness in vivo is an important indicator of the status of a joint as the various degenerative and inflammatory arthritides directly affect the condition of the cartilage. In order to assess the precision of thickness measurements of hyaline articular cartilage, we undertook a pilot study using MR imaging, plain radiography, and ultrasonography (US). We measured the cartilage of the hip and knee joints in 10 persons (4 healthy volunteers and 6 patients). The joints in each patient were examined on two separate occasions using each modality. In the hips a swell as the knee joints, the most precise measuring method was plain film radiography. For radiographs of the knees obtained in the standing position, the coefficient of variation was 6.5%; in the hips this figure was 6.34%. US of the knees and MR imaging of the hips were the second best modalities in the measurement of cartilage thickness. In addition, MR imaging enabled the most complete visualization of the joint cartilage. (orig.).

  11. Mandibular thickness measurements in young dentate adults.

    Science.gov (United States)

    Beaty, Narlin B; Le, Thomas T

    2009-09-01

    To measure thicknesses in clinical landmark areas of the dentate mandibles of young men and women. Using standard radiologic software, we obtained mean (SD) thickness measurements at the inferior or posterior borders of the mandible at the following 7 surgically useful sites: (1) the symphysis, (2) a point halfway between the symphysis and the mental nerve, (3) the mental nerve, (4) a point halfway between the mental nerve and the facial artery notch, (5) the facial artery notch, (6) the angle vertex, and (7) the ramus-condylar neck border. University hospital. A total of 150 dentate men and 75 dentate women aged 18 to 30 years who had undergone computed tomography of the head and neck region during the period of December 20, 2006 to February 20, 2007. Thicknesses of 7 mandibular sites. Mean (SD) thicknesses at the 7 mandibular sites were as follows: symphysis, 14.03 (1.53) mm for men and 13.21 (1.46) mm for women; halfway between the symphysis and the mental nerve, 11.17 (1.37) mm for men and 10.00 (1.08) mm for women; mental nerve, 9.48 (1.28) mm for men and 8.72 (1.00) mm for women; halfway between the mental nerve and the facial artery notch, 10.33 (1.24) mm for men and 9.45 (0.92) mm for women; facial artery notch, 7.27 (0.82) mm for men and 7.10 (0.88) mm for women; angle vertex, 5.42 (0.90) mm for men and 5.39 (0.66) mm for women; and ramus-condylar neck border, 5.90 (0.86) mm for men and 5.85 (0.71) mm for women. Clinical landmark areas in young dentate mandibles have mean thicknesses with limited SDs. The thickness measurements obtained at the sites in this study provide practical reference information for mandibular reconstruction and bicortical screw length estimation.

  12. Cement thickness measurements in cased boreholes

    International Nuclear Information System (INIS)

    Wahl, J.S.; Schuster, N.A.

    1978-01-01

    Methods and apparatus are provided for logging a borehole having solid matter along at least a portion of the wall thereof. Gamma radiation is emitted from the borehole into the surrounding media, and the amount of radiation which returns to the borehole is measured by three detectors located at different distances from the source of radiation, so as to be primarily sensitive to radiation which has respectively penetrated to three different depths in the surrounding media. The thickness of the solid matter on the borehole wall is then determined from the three gamma radiation measurements

  13. Comparisons of foveal thickness and slope after macular hole surgery with and without internal limiting membrane peeling.

    Science.gov (United States)

    Ohta, Kouichi; Sato, Atsuko; Senda, Nami; Fukui, Emi

    2018-01-01

    We have shown that the foveal contour was asymmetrical after idiopathic macular hole (MH) closure by pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling. The purpose of this study was to determine whether these morphological changes differ in eyes after PPV without ILM peeling. Ten eyes of 10 patients that underwent PPV without ILM peeling and 12 eyes of 11 patients with ILM peeling were studied. The MH in all eyes was 6 months after the surgery. The mean parafoveal retinal thickness in the non-peeled group was 367.1 µm in the nasal (N), 353.0 µm in the temporal (T), 366.9 µm in the superior (S), and 357.3 µm in the inferior (I) sectors. The T, S, and I sectors were significantly thicker than the corresponding sectors in the ILM peeled group ( p =0.0008, 0.003, and 0.03, respectively). The mean ganglion cell complex was thicker not only in the N sector but also in the T sector in the non-peeled group. The mean retinal slopes in the non-peeled group (N, 40.2°; T, 37.6°; S, 41.2°; I, 39.5°) were flatter than those in the peeled group (N, 52.3°; T, 43.6°; S, 50.8°; I, 51.9°; p =0.009, 0.09, 0.008, and 0.017, respectively). The symmetrical fovea after MH surgery in the non-ILM peeled eyes indicates that the asymmetrical fovea after ILM peeling was probably due to the ILM peeling.

  14. Measuring coating thicknesses on continuously moving material

    International Nuclear Information System (INIS)

    Holler, J.H.; Stanton, W.B.; Spongr, J.J.; Joffe, B.B.; Raffelsberger, P.W.; Tiebor, J.E.

    1982-01-01

    A method and apparatus using radiation techniques for measuring coating thicknesses on continuously moving strip material without altering a predetermined path along which it travels. A shuttle carrying a measuring probe having a radioactive isotope source and a detection device is provided for reciprocation along a preselected segment of the path of the strip. The shuttle and the probe are releasably engaged with the strip and carried thereby for synchronous movement therewith in the forward direction during a measurement cycle, and are disengaged from the strip when no measurement is being made, the movement of the shuttle then being controlled by an independent drive mechanism, shown as a belt drive, which reciprocates the shuttle along the rails. A belt drives it forward more slowly than the strip, which then engages the shuttle to pull it at strip speed, allowed by a pulley clutch. (author)

  15. Complications of Macular Peeling

    Science.gov (United States)

    Asencio-Duran, Mónica; Manzano-Muñoz, Beatriz; Vallejo-García, José Luis; García-Martínez, Jesús

    2015-01-01

    Macular peeling refers to the surgical technique for the removal of preretinal tissue or the internal limiting membrane (ILM) in the macula for several retinal disorders, ranging from epiretinal membranes (primary or secondary to diabetic retinopathy, retinal detachment…) to full-thickness macular holes, macular edema, foveal retinoschisis, and others. The technique has evolved in the last two decades, and the different instrumentations and adjuncts have progressively advanced turning into a safer, easier, and more useful tool for the vitreoretinal surgeon. Here, we describe the main milestones of macular peeling, drawing attention to its associated complications. PMID:26425351

  16. Assessment of Open-Angle Glaucoma Peripapillary and Macular Choroidal Thickness Using Swept-Source Optical Coherence Tomography (SS-OCT.

    Directory of Open Access Journals (Sweden)

    Yong Ju Song

    Full Text Available To compare peripapillary and macular choroidal thickness (PCT and MCT between open-angle glaucoma (OAG and normal controls using swept-source optical coherence tomography (SS-OCT, and to evaluate global and localized relationships between choroidal thickness and various factors in OAG, also using SS-OCT.In this cross-sectional comparative study, 134 OAG patients and 73 normal controls were examined. PCT (global, 12 clock-hour sectors, MCT (global, six sectors were measured by SS-OCT. The difference in choroidal thickness between the OAG patients and the normal controls was analyzed. The relationships between choroidal thickness and various factors including age, sex, spherical equivalent (SE, axial length (AXL, central corneal thickness (CCT, intraocular pressure (IOP, peripapillary retinal nerve fiber layer thickness (pRNFLT, visual field mean deviation (MD, ganglion cell-inner plexiform layer thickness (GCIPLT, and disc area were analyzed by univariate and multivariate linear regression. Global and regional analyses were performed in 12 segments of the peripapillary circle and in six sectors of the macula.There were significant differences in global PCT and MCT between the OAG patients and the normal controls (115.22±41.17 vs. 138.89±44.70, P<0.001, (184.36±57.15 vs. 209.25±61.11, P = 0.004. The difference in global PCT remained, both after adjusting for age, AXL (117.08±3.45 vs. 135.47±4.70, P = 0.002 and also after adjusting for age, AXL, disc area (117.46±3.46 vs. 135.67±4.67, P = 0.002. But the difference in global MCT did not remain after adjusting for age, AXL, SE (188.18±4.46 vs. 202.25±6.08, P = 0.066. PCT showed significant differences between the groups in all of the 12 clock-hour sectors. These differences remained after adjusting for age, AXL and for age, AXL, disc area, with the exception of the 10 o'clock (o/c sector. MCT in six sectors showed differences between the two groups, but they did not remain after adjusting

  17. Successful closure of treatment-naïve, flat edge (Type II, full-thickness macular hole using inverted internal limiting membrane flap technique

    Directory of Open Access Journals (Sweden)

    Hussain N

    2016-10-01

    Full Text Available Nazimul Hussain,1 Anjli Hussain2 1Department of Ophthalmology, Al Zahra Hospital, 2Al Zahra Medical Center, Dubai, United Arab Emirates Objective: The objective of this study was to present the outcome of the internal limiting membrane (ILM peeling flap technique for a treatment-naïve, flat edge (Type II, full-thickness macular hole (MH. Methods: A 52-year-old man presented with complaints of decreased vision and seeing black spot. He was diagnosed to have a flat edge, full-thickness MH, which was confirmed by optical coherence tomography (OCT. He underwent 23G vitrectomy with brilliant blue G-assisted inverted ILM peeling with an inverted flap over the hole followed by fluid gas exchange. Results: Postoperative follow-up until 3 months showed successful closure of the MH, which was confirmed by OCT. The best-corrected visual acuity improved from baseline 6/60 to 6/12 at the final follow-up. Conclusion: Using the inverted ILM flap technique, a treatment-naïve, flat edge (Type II, full thickness MH achieved successful anatomical and functional outcomes. Keywords: macular hole, inverted ILM, optical coherence tomography

  18. New portable pipe wall thickness measuring technique

    Science.gov (United States)

    Pascente, Joseph E.

    1998-03-01

    One of the biggest inspection challenges facing many of the process industries; namely the petrochemical, refining, fossil power, and pulp and paper industries is: How to effectively examine their insulated piping? While there are a number of failure mechanisms involved in various process piping systems, piping degradation through corrosion and erosion are by far the most prevalent. This degradation can be in the form of external corrosion under insulation, internal corrosion through a variety of mechanisms, and internal erosion caused by the flow of the product through the pipe. Refineries, chemical plants and electrical power plants have MANY thousands of miles of pipe that are insulated to prevent heat loss or heat absorption. This insulation is often made up of several materials, with calcium based material being the most dense. The insulating material is usually wrapped with an aluminum or stainless steel outer wrap. Verification of wall thickness of these pipes can be accomplished by removing the insulation and doing an ultrasound inspection or by taking x- rays at a tangent to the edge of the pipe through the insulation. Both of these processes are slow and expensive. The time required to obtain data is measured in hours per meter. The ultrasound method requires that the insulation be plugged after the inspection. The surface needs to be cleaned or the resulting data will not be accurate. The tangent x-ray only shows two thicknesses and requires that the area be roped off because of radiation safety.

  19. Cost-effectiveness of internal limiting membrane peeling versus no peeling for patients with an idiopathic full-thickness macular hole: results from a randomised controlled trial.

    Science.gov (United States)

    Ternent, Laura; Vale, Luke; Boachie, Charles; Burr, Jennifer M; Lois, Noemi

    2012-03-01

    To determine whether internal limiting membrane (ILM) peeling is cost-effective compared with no peeling for patients with an idiopathic stage 2 or 3 full-thickness macular hole. A cost-effectiveness analysis was performed alongside a randomised controlled trial. 141 participants were randomly allocated to receive macular-hole surgery, with either ILM peeling or no peeling. Health-service resource use, costs and quality of life were calculated for each participant. The incremental cost per quality-adjusted life year (QALY) gained was calculated at 6 months. At 6 months, the total costs were on average higher (£424, 95% CI -182 to 1045) in the No Peel arm, primarily owing to the higher reoperation rate in the No Peel arm. The mean additional QALYs from ILM peel at 6 months were 0.002 (95% CI 0.01 to 0.013), adjusting for baseline EQ-5D and other minimisation factors. A mean incremental cost per QALY was not computed, as Peeling was on average less costly and slightly more effective. A stochastic analysis suggested that there was more than a 90% probability that Peeling would be cost-effective at a willingness-to-pay threshold of £20,000 per QALY. Although there is no evidence of a statistically significant difference in either costs or QALYs between macular hole surgery with or without ILM peeling, the balance of probabilities is that ILM Peeling is likely to be a cost-effective option for the treatment of macular holes. Further long-term follow-up data are needed to confirm these findings.

  20. Full Thickness Macular Hole Closure after Exchanging Silicone-Oil Tamponade with C3F8 without Posturing

    Directory of Open Access Journals (Sweden)

    Tina Xirou

    2011-05-01

    Full Text Available Purpose: To report a case of macular hole closure after the exchange of a silicone-oil tamponade with gas C3F8 14%. Method: A 64-year-old female patient with a stage IV macular hole underwent a three-port pars-plana vitrectomy and internal limiting membrane peeling. Due to the patient’s chronic illness (respiratory problems, a silicone-oil tamponade was preferred. However, the macula hole was still flat opened four months postoperatively. Therefore, the patient underwent an exchange of silicone oil with gas C3F8 14%. No face-down position was advised postoperatively due to her health problems. Results: Macular hole closure was confirmed with optical coherence tomography six weeks after exchanging the silicone oil with gas. Conclusions: Macular hole surgery using a silicone-oil tamponade has been proposed as treatment of choice for patients unable to posture. In our case, the use of a long-acting gas (C3F8 14%, even without posturing, proved to be more effective.

  1. Correlation between the optical coherence tomography and electroretinogram in retinal vein occlusion macular edema

    Directory of Open Access Journals (Sweden)

    Ya Xu

    2014-11-01

    Full Text Available AIM: To evaluate the correlation between retinal thickness and photopic flash electroretinogram(ERGparameters(Cone a-wave, Cone b-wave, and 30Hz flickerin patients with central retinal vein occlusion(CRVOand macular edema. METHODS: A total of 25 patients(25 CRVO eyes and 25 unaffected fellow eyeswith CRVO underwent the examination of optical coherence tomography(OCTand photopic falsh ERG. The amplitude and implicit time of the ERG parameters were extracted from the ERG traces. Retinal thicknesses were measured by OCT in nine macular subfields. Then the correlations between ERG parameters and macular morphological parameters were analyzed. RESULTS: The Cone b-wave and 30Hz flicker implicit time were correlated with macular retinal thickness in seven out of nine subfields, excluding the temporal subfields. CONCLUSION: The retinal thickness of the macular edema may be associated with inner retinal function in CRVO patients.

  2. Effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Mohana Kuppuswamy Parthasarathy

    2015-01-01

    Full Text Available Aim: The aim of the present study was to study the effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography (OCT. Materials and Methods: One hundred and fifty-one subjects were included from the normative study of foveal morphology carried out at our hospital. Subjects underwent comprehensive eye examination and macular scanning using Cirrus high-definition OCT and axial length (AXL measurement. Macular cube 512 × 128 scan protocol was used for scanning the macula. Automated measurements of the fovea namely foveal diameter, foveal slope (lateral measurements and foveal depth (axial measurement were taken. A correction factor for ocular magnification was done using the formula t = p × q × s, where "t0" is the corrected measurement, "p" is the magnification of OCT, "q0" is the ocular magnification, and "s" is the measurement on OCT without correction. The difference between corrected and uncorrected measurements was evaluated for statistical significance. Results: Mean AXL was 22.95 ± 0.78 mm. Refractive error ranged from −3D to +4D. Mean difference between measured and corrected foveal diameter, slope and depth was 166.05 ± 95.37 ΅m (P < 0.001, 0.81° ± 0.53° (P < 0.001 and 0.05 ± 0.49 ΅m (P = 0.178 respectively. AXL lesser than the OCT calibrated value of 24.46 mm showed an increased foveal diameter (r = 0.961, P < 0.001 and a reduced foveal slope (r = −0.863, P < 0.001 than the corrected value. Conclusion: Lateral measurements made on OCT varied with AXL s other than the OCT calibrated value of 24.46 mm. Therefore, to estimate the actual dimensions of a retinal lesion using OCT, especially lateral dimensions, we recommend correction for the ocular magnification factor.

  3. Thickness measuring instrument for rubber cord calender production

    International Nuclear Information System (INIS)

    Ye Songfeng

    1988-01-01

    The thickness measuring gauge has been used to measure the rubber film thickness on the coating of textile cord at tire four cord calenders. Combined with micro-computer it completes the automatic control system and acheives automatic thickness measurement and adjustment. The fundamentals, construction, specifications, characteristic and application results are described. Prominent economic benefit has been gained for tire production

  4. Choroidal thickness measurements with optical coherence tomography in branch retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Muge Coban-Karatas

    2016-05-01

    Full Text Available AIM: To evaluate central macular thickness (CMT and mean choroidal thickness (MCT in eyes with branch retinal vein occlusion (BRVO, before and after ranibizumab treatment using spectral domain-optical coherence tomography (SD-OCT. METHODS: Forty-two patients with unilateral BRVO and macular edema were included in this study. There were 25 men and 17 women. Using SD-OCT, choroidal thickness was measured at 500 µm intervals up to 1500 µm temporal and nasal to the fovea. MCT was calculated based on the average of the 7 locations. All the eyes with BRVO were treated with intravitreal ranibizumab (0.5 mg/0.05 mL. Comparisons between the BRVO and fellow eyes were analyzed using Mann-Whitney U test. Pre-injection and post-injection measurements were analyzed using Wilcoxon test and repeated measure analysis. RESULTS: At baseline, there was a significant difference between the BRVO and fellow eyes in MCT [BRVO eyes 245 (165-330 µm, fellow eyes 229 (157-327 µm] and CMT [BRVO eyes 463 (266-899 µm, fellow eyes 235 (148-378 µm (P=0.041, 0.0001, respectively]. Following treatment, CMT [295 (141-558 µm] and MCT [229 (157-329 µm] decreased significantly compared to the baseline measurements (P=0.001, 0.006, respectively. Also BCVA (logMAR improved significantly (P=0.0001 in the BRVO eyes following treatment. After treatment CMT [BRVO eyes 295 (141-558 µm, fellow eyes 234 (157-351 µm] and MCT [BRVO eyes 229 (157-329 µm, fellow eyes 233 (162-286 µm] values did not reveal any significant difference in BRVO eyes and fellow eyes (P=0.051, 0.824, respectively. CONCLUSION: In eyes with BRVO, CMT and MCT values are greater than the fellow eyes, and decrease significantly following ranibizumab injection.

  5. Macular pigment optical density is related to serum lutein in retinitis pigmentosa

    Science.gov (United States)

    Purpose: To determine whether macular pigment optical density (MPOD) is related to the degree of cystoid macular edema (CME) in patients with retinitis pigmentosa. Methods: We measured MPOD with heterochromatic flicker photometry and central foveal retinal thickness with optical coherence tomography...

  6. Avaliação da espessura da camada de fibras nervosas da retina e mácula em pacientes com ambliopia Thickness of the retinal nerve fiber layer, macular thickness, in patients with amblyopia

    Directory of Open Access Journals (Sweden)

    Juliana Mitre

    2010-02-01

    Full Text Available OBJETIVO: Avaliar a espessura da camada de fibras nervosas da retina em olhos amblíopes e comparar com olhos normais e certificar se há correlação com a redução da acuidade visual. Além disso, este estudo se propõe avaliar a eficácia e eficiência em uma série de casos do protótipo de um equipamento nacional de magnificação para leitura. MÉTODOS: Participaram deste estudo 30 pacientes na faixa etária entre 9 e 80 anos (17 do sexo masculino. Foi desenvolvido um aparelho portátil, patenteado pela Unifesp (PI#020050145260, com um sistema de captura de imagens acoplado a um monitor de 5,6 polegadas proporcionando um aumento de 15 x. Foram analisadas a eficácia da acuidade visual e a eficiência de leitura após a utilização do protótipo proposto. RESULTADOS: Seis pacientes (20% apresentaram AV 8M, 12 pacientes (40% apresentaram AV 6M, 7 pacientes (23,3% apresentaram 5 M, 5 pacientes (16,7% apresentaram 4M. A média de acuidade visual antes da utilização do SLP medida pela tabela LHNV-1 logMAR foi de 5,75M e após a utilização 100% dos pacientes atingiram a eficácia de AV J1. CONCLUSÃO: O protótipo do SLP mostrou-se um recurso alternativo no processo de inclusão social das pessoas com baixa visão com diferentes níveis de resíduo visual. Também pode proporcionar incentivo psicológico, permitir conforto, mobilidade e independência àqueles que necessitam de uma leitura mais prolongada e maior distância de trabalho.OBJECTIVE: To compare the thickness of the retinal nerve fiber layer (RNFLand the macular thickness of the amblyopic eye with those of the non-amblyopic eye in patients with unilateral amblyopia using optical coherence tomography (OCT. METHODS: OCT was performed for13 patients with unilateral amblyopia who had no neurologic disease. Nine male andfour female patients, whose ages ranged from 23 to 63 years, were enrolled in the study. The RNFL thickness average analysis program was used to evaluate mean

  7. Intravitreal triamcinolone for diffuse diabetic macular oedema.

    LENUS (Irish Health Repository)

    Gibran, S K

    2012-02-03

    AIM: To evaluate the efficacy of intravitreal triamcinolone (IVTA) for the treatment of diffuse diabetic macular oedema (DME) refractory to conventional argon macular laser therapy. METHODS: A prospective, consecutive, and noncomparative case series was undertaken involving 38 eyes of 38 patients with refractory DME. Triamcinolone acetonide (4 mg) in 0.1 ml was injected intravitreally. LogMar visual acuity (VA) and macular thickness measured by ocular coherence tomography (OCT) were assessed preoperatively and postoperatively at 1, 3, and 6 months. RESULTS: All patients completed 6 months of follow up. VA (mean+\\/-SD) improved from 0.905+\\/-0.23 to 0.605+\\/-0.28, 0.555+\\/-0.29, and 0.730+\\/-0.30 at 1, 3, and 6 months, respectively. Macular thickness baseline (mean+\\/-SD) on OCT was 418.7+\\/-104.2 microm and this decreased to 276.9+\\/-72.6 microm, 250.6+\\/-53.1 microm, and 308.8+\\/-87.3 microm at 1, 3, and 6 months, respectively. CONCLUSIONS: IVTA may be a potential temporary treatment for refractory DME. It is effective in decreasing macular thickness and improving VA but the effect lasts approximately for 6 months in the majority of patients. Further investigations are required to establish the safety of IVTA for the treatment of DME.

  8. Manual for target thickness measurement by alpha particle irradiation

    International Nuclear Information System (INIS)

    Dias, J.F.; Martins, M.N.

    1990-04-01

    A system is described for thin-target thickness measurement through the alpha particle energy loss when them traverse the target. It is also described the program used in the analysis of the target thickness. (L.C.) [pt

  9. Beta ray backscattering studies for thickness measurements

    Energy Technology Data Exchange (ETDEWEB)

    Singh, M; Sharma, K K [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1979-01-01

    Back-scattering of beta rays from /sup 204/Tl (Esub(..beta..)max = 740 keV) and /sup 90/Sr-/sup 90/Y (Esub(..beta..)max =550 and 2250 keV) has been studied in an improved reflection geometry, using annular sources, from a number of elemental targets with Z values ranging from 13 to 82. Source to target and target to detector geometry factors are 0.0225 and 0.0282 respectively. Values of saturation back scattering thickness obtained in the two cases are 72 +- 10 and 190 +- 40 mg/cm/sup 2/ respectively. It is observed that the intensity of back scattered radiation varies linearly with thickness upto a value of 12 +- 2 mg/cm/sup 2/ in /sup 204/Tl and 17 +- 3 mg/cm/sup 2/ in /sup 90/Sr-/sup 90/Y.

  10. Reproducibility of Macular Pigment Optical Density Measurement by Two-wave Length Auto-fluorescence in a Clinical Setting

    Science.gov (United States)

    You, Qi-Sheng; Bartsch, Dirk-Uwe G.; Espina, Mark; Alam, Mostafa; Camacho, Natalia; Mendoza, Nadia; Freeman, William

    2015-01-01

    Purpose Macular pigment, composed of lutein, zeaxanthin, and meso-zeaxanthin, is postulated to protect against age-related macular degeneration (AMD), likely due to filtering blue light and its antioxidant properties. Macular pigment optical density (MPOD) is reported to be associated with macular function evaluated by visual acuity and multifocal electroretinogram. Given the importance of macular pigment, reliable and accurate measurement methods are important. The main purpose of current study is to determine the reproducibility of MPOD measurement by two-wave length auto-fluorescence method using scanning laser ophthalmoscopy. Methods Sixty eight eyes of 39 persons were enrolled in the study, including 11 normal eyes, 16 eyes with wet AMD, 16 eyes with dry AMD, 11 eyes with macular edema due to diabetic mellitus, branch retinal vein occlusion or macular telangiectasia and 14 eyes with tractional maculopathy including vitreomacular traction, epiretinal membrane or macular hole. MPOD was measured with a two-wavelength (488 and 514 nm) auto-fluorescence method with the Spectralis HRA+OCT after pupil dilation. The measurement was repeated for each eye 10 minutes later. The Analysis of variance (ANOVA) and Bland-Altman plot were used to assess the reproducibility between the two measurements. Results The mean MPOD at eccentricities of 1° and 2° was 0.36±0.17 (range: 0.04–0.69) and 0.15±0.08(range: −0.03, 0.35) for the first measurement and 0.35±0.17 (range: 0.02, 0.68) and 0.15±0.08 (range: −0.01, 0.33) for the second measurement respectively. The difference between the two measurements was not statistically significant, and the Bland-Altman plot showed 7.4% and 5.9% points outside the 95% limits of agreement, indicating an overall excellent reproducibility. Similarly, there is no significant difference between the first and second measurements of MPOD volume within eccentricities of 1°, 2° and 6° radius, and the Bland-Altman plot showed 8.8%, 2.9% and

  11. Interferometric measurement of film thickness during bubble blowing

    Science.gov (United States)

    Wang, Z.; Mandracchia, B.; Ferraro, V.; Tammaro, D.; Di Maio, E.; Maffettone, P. L.; Ferraro, P.

    2017-06-01

    In this paper, we propose digital holography in transmission configuration as an effective method to measure the time-dependent thickness of polymeric films during bubble blowing. We designed a complete set of experiments to measure bubble thickness, including the evaluation of the refractive index of the polymer solution. We report the measurement of thickness distribution along the film during the bubble formation process until the bubble`s rupture. Based on those data, the variation range and variation trend of bubble film thickness are clearly measured during the process of expansion to fracture is indicated.

  12. Pelvic floor muscle thickness measured by perineal ultrasonography

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen; Juul, N; Grønvall, S

    1991-01-01

    Pelvic floor muscle thickness was assessed in nine healthy female physiotherapists by perineal sonography. All measurements were performed as triple-measurements. The aims were to assess the reliability of the measurements and to establish a reference material. The muscle thickness at rest...

  13. Thickness measurement by using cepstrum ultrasonic signal processing

    International Nuclear Information System (INIS)

    Choi, Young Chul; Yoon, Chan Hoon; Choi, Heui Joo; Park, Jong Sun

    2014-01-01

    Ultrasonic thickness measurement is a non-destructive method to measure the local thickness of a solid element, based on the time taken for an ultrasound wave to return to the surface. When an element is very thin, it is difficult to measure thickness with the conventional ultrasonic thickness method. This is because the method measures the time delay by using the peak of a pulse, and the pulses overlap. To solve this problem, we propose a method for measuring thickness by using the power cepstrum and the minimum variance cepstrum. Because the cepstrums processing can divides the ultrasound into an impulse train and transfer function, where the period of the impulse train is the traversal time, the thickness can be measured exactly. To verify the proposed method, we performed experiments with steel and, acrylic plates of variable thickness. The conventional method is not able to estimate the thickness, because of the overlapping pulses. However, the cepstrum ultrasonic signal processing that divides a pulse into an impulse and a transfer function can measure the thickness exactly.

  14. Infrared sensing and the measurement of oil slick thickness

    International Nuclear Information System (INIS)

    Brown, H.M.; Baschuk, J.J.; Goodman, R.H.

    1998-01-01

    The issue of whether infrared images can be used to detect the thickness of a marine oil spill was discussed. Infrared images of oil spills on water show density variations because of variations in oil temperature and emissivity. These observations have been used to determine thickness variations in the oil. Experiments were conducted in a large wave basin using two typical crude oils in the thickness range of 1 mm to 10 mm. Infrared images of oil spills were recorded and simultaneous thickness measurements were made using an acoustic thickness gauge. The study showed that there is no relationship between infrared image pixel greyness and the thickness measured with an acoustic probe. It was not possible to determine the volume of a spill using infrared images. 2 refs., 1 tab., 4 figs

  15. Digital Thickness Measurement of a Transparent Plastic Orthodontic Device

    Science.gov (United States)

    Kim, Yoon-Hwan; Rhim, Sung-Han

    2018-05-01

    A transparent orthodontic device is used to move the teeth to the final calibration position to form a proper set of teeth. Because the uniform thickness of the device plays an important role in tooth positioning, the accuracy of the device's thickness profile is important for effective orthodontic treatment. However, due to the complexity of the device's geometry and the transparency of the device's material, measuring the complete thickness profile has been difficult. In the present study, a new optical scanning method to measure the thickness profile of transparent plastic orthodontic devices is proposed and evaluated by using scanning electron microscopy (SEM). The error of the new measurement method is less than ±18 μm. The new method can be used to measure the thickness of non-specific, multi-curved, transparent orthodontic devices.

  16. Pelvic floor muscle thickness measured by perineal ultrasonography

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen; Juul, N; Grønvall, S

    1991-01-01

    Pelvic floor muscle thickness was assessed in nine healthy female physiotherapists by perineal sonography. All measurements were performed as triple-measurements. The aims were to assess the reliability of the measurements and to establish a reference material. The muscle thickness at rest...... and at contraction was 9.4 +/- 0.8 mm and 11.5 +/- 1.1 mm respectively (mean +/- SD). Contraction increased the thickness by 2.2 +/- 0.8 mm or 23 +/- 8%. The intra- and inter observer standard deviation of the estimate was in the range of 4-6%. In conclusion, we find the reliability of the measurements acceptable....

  17. The application of XRF to the thickness measurement of paper

    International Nuclear Information System (INIS)

    Guo Wei; Lai Wangchang; Guo Shengliang; Cheng Feng

    2007-01-01

    The purpose of this paper is to study on the application of XRF to the thickness measurement of paper. The mass thickness of a number of paper samples were respectively measured by the X-ray absorption method and the primary rays of radiated sources scattering method. The measurement results had been compared with each other, and got several helpful discussions. The measurement was using the IED-2000P type X-ray fluorescence analyzer from Chengdu Micro-Particle Technology Ltd., which is composed of a Si-pin X-ray detector with thermo electrical cooler, and double isotope sources ( 238 Pu). The experiment indicated that the veracity of the X-ray absorption method on the thickness measurement of paper is better than the primary rays of radiated sources scattering method, and the application of the primary rays of radiated sources scattering method to the thickness measurement of paper is verified as feasible. (authors)

  18. Wall thickness measurements using digital radiography - state of the art

    International Nuclear Information System (INIS)

    Wawrzinek, T.; Zscherpel, U.; Bellon, C.

    1997-01-01

    Projection radiography is a method long since used for wall thickness measurements in pipes. Another method sometimes applied is thickness determination based on measuring changes of the optical density by using radioactive isotopes, as in this case the effects of stray radiation are negligible. The two methods hitherto were to be performed manually, and wall thickness data were derived by calculations with a pocket calculator. The required measuring and calculating work can now be automated by way of computerized processing of digitised images. The paper presents the software for automated evaluation of data of a selected location after system calibration. (orig./CB) [de

  19. Thickness Measurement of Surface Attachment on Plate with Lamb Wave

    Science.gov (United States)

    Ma, Xianglong; Zhang, Yinghong; Wen, Lichao; He, Yehu

    2017-12-01

    Aiming at the thickness detection of the plate surface attachment, a nondestructive testing method based on the Lamb wave is presented. This method utilizes Lamb wave propagation characteristics of signals in a bi-layer medium to measure the surface attachment plate thickness. Propagation of Lamb wave in bi-layer elastic is modeled and analyzed. The two-dimensional simulation model of electromagnetic ultrasonic plate - scale is established. The simulation is conducted by software COMSOL for simulation analysis under different boiler scale thickness wave form curve. Through this study, the thickness of the attached material can be judged by analyzing the characteristics of the received signal when the thickness of the surface of the plate is measured.

  20. Measurement of the thickness of thin films by backscattered protons

    International Nuclear Information System (INIS)

    Samaniego, L.E.Q.

    1976-07-01

    The method of backscattered protons has been used to measure the thickness of thin films. A monoenergetic beam of protons is directed on the film to be measured and the backscattered protons are detected with a particle detector. The film thickness is calculated from the energy spectrum of the protons. In the case of films consisting of several layers of elements with well separated atomic masses, it is possible to separate the spectra of protons scattered from the different elements, permitting a measurement of the thicknesses of the different layers. The method consists of calculating the energy loss of the protons throughout their trajectory, from the point of incidence on the film to the final detection. Thicknesses were measured for the following film combinations: gold on mylar, chromium on mylar, gold on chromium on mylar, and pure mylar. (Author) [pt

  1. Macular pigment optical density spatial distribution measured in a subject with oculocutaneous albinism.

    Science.gov (United States)

    Putnam, Christopher M; Bland, Pauline J

    2014-01-01

    Previous studies of macular pigment optical density (MPOD) distribution in individuals with oculocutaneous albinism (OCA) have primarily used objective measurement techniques including fundus reflectometry and autofluorescence. We report here on a subject with OCA and their corresponding MPOD distribution assessed through heterochromatic flicker photometry (HFP). A subject with a history of OCA presented with an ocular history including strabismus surgery of the LE with persistent amblyopia and mild, latent nystagmus. Best corrected visual acuity was 20/25- RE and 20/40- LE. Spectral domain optical coherence tomography (SD-OCT) and fundus photography were also obtained. Evaluation of MPOD spatial distribution up to 8 degrees eccentricity from the fovea was performed using HFP. SD-OCT indicated a persistence of multiple inner retinal layers within the foveal region in the RE and LE including symmetric foveal thickening consistent with foveal hypoplasia. Fundus photography showed mild retinal pigmented epithelial (RPE) hypopigmentation and a poorly demarcated macula. OriginPro 9 was used to plot MPOD spatial distribution of the subject and a 33-subject sample. The OCA subject demonstrated a foveal MPOD of 0.10 with undetectable levels at 6 degrees eccentricity. The study sample showed a mean foveal MPOD of 0.34 and mean 6 degree eccentricity values of 0.03. Consistent with previous macular pigment (MP) studies of OCA, overall MPOD is reduced in our subject. Mild phenotypic expression of OCA with high functional visual acuity may represent a Henle fiber layer amenable to additional MP deposition. Further study of MP supplementation in OCA patients is warranted. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  2. Determination of gold coating thickness measurement by using EDXRF

    International Nuclear Information System (INIS)

    Meor Yusoff Meor Sulaian; Masliana Muslimin; Fadlullah Jili Fursani

    2005-01-01

    The paper relates a study on the development of an analysis procedure for measuring the gold coating thickness using EDXRF technique. Gold coating thickness was measured by relating the counts under the Au L? peak its thickness value. In order to get a reasonably accurate result, a calibration graph was plotted using five gold-coated reference standards of different thickness. The calibration graph shows a straight line for thin coating measurement until 0.9 μm. Beyond this the relationship was not linear and this may be resulted from the self-absorption effect. Quantitative analysis was also performed on two different samples of gold coated jewelry and a phone connector. Result from the phone connector analysis seems to agree with the manufacturer gold coating value. From the analysis of gold-coated jewelry it had been able to differentiate the two articles as gold wash and gold electroplated. (Author)

  3. Using laser to measure stem thickness and cut weed stems

    DEFF Research Database (Denmark)

    Heisel, T.; Schou, Jørgen; Andreasen, C.

    2002-01-01

    Stem thickness of the weed Solanum nigrum and the crop sugarbeet was determined with a He-Ne laser using a novel non-destructive technique measuring stem shadow. Thereafter, the stems were cut close to the soil surface with a CO2 laser. Treatments were carried out on pot plants, grown....... A binary model was also tested. The non-linear model incorporating stem thickness described the data best, indicating that it would be possible to optimize laser cutting by measuring stem thickness before cutting. The general tendency was that more energy was needed the thicker the stem. Energy uses...... in the greenhouse, at two different growth stages, and plant dry matter was measured 2-5 weeks after treatment. The relationship between plant dry weight and laser energy was analysed using two different non-linear dose-response regression models; one model included stem thickness as a variable, the other did not...

  4. Model-based cartilage thickness measurement in the submillimeter range

    International Nuclear Information System (INIS)

    Streekstra, G. J.; Strackee, S. D.; Maas, M.; Wee, R. ter; Venema, H. W.

    2007-01-01

    Current methods of image-based thickness measurement in thin sheet structures utilize second derivative zero crossings to locate the layer boundaries. It is generally acknowledged that the nonzero width of the point spread function (PSF) limits the accuracy of this measurement procedure. We propose a model-based method that strongly reduces PSF-induced bias by incorporating the PSF into the thickness estimation method. We estimated the bias in thickness measurements in simulated thin sheet images as obtained from second derivative zero crossings. To gain insight into the range of sheet thickness where our method is expected to yield improved results, sheet thickness was varied between 0.15 and 1.2 mm with an assumed PSF as present in the high-resolution modes of current computed tomography (CT) scanners [full width at half maximum (FWHM) 0.5-0.8 mm]. Our model-based method was evaluated in practice by measuring layer thickness from CT images of a phantom mimicking two parallel cartilage layers in an arthrography procedure. CT arthrography images of cadaver wrists were also evaluated, and thickness estimates were compared to those obtained from high-resolution anatomical sections that served as a reference. The thickness estimates from the simulated images reveal that the method based on second derivative zero crossings shows considerable bias for layers in the submillimeter range. This bias is negligible for sheet thickness larger than 1 mm, where the size of the sheet is more than twice the FWHM of the PSF but can be as large as 0.2 mm for a 0.5 mm sheet. The results of the phantom experiments show that the bias is effectively reduced by our method. The deviations from the true thickness, due to random fluctuations induced by quantum noise in the CT images, are of the order of 3% for a standard wrist imaging protocol. In the wrist the submillimeter thickness estimates from the CT arthrography images correspond within 10% to those estimated from the anatomical

  5. Asymmetric Macular Structural Damage Is Associated With Relative Afferent Pupillary Defects in Patients With Glaucoma

    Science.gov (United States)

    Gracitelli, Carolina P. B.; Tatham, Andrew J.; Zangwill, Linda M.; Weinreb, Robert N.; Abe, Ricardo Y.; Diniz-Filho, Alberto; Paranhos, Augusto; Baig, Saif; Medeiros, Felipe A.

    2016-01-01

    Purpose We examined the relationship between relative afferent pupillary defects (RAPDs) and macular structural damage measured by macular thickness and macular ganglion cell-inner plexiform layer (mGCIPL) thickness in patients with glaucoma. Methods A cross-sectional study was done of 106 glaucoma patients and 85 healthy individuals from the Diagnostic Innovations in Glaucoma Study. All subjects underwent standard automated perimetry (SAP) and optic nerve and macular imaging using Cirrus Spectral Domain Optical Coherence Tomography (SDOCT). Glaucoma was defined as repeatable abnormal SAP or progressive glaucomatous changes on stereo photographs. Pupil responses were assessed using an automated pupillometer, which records the magnitude of RAPD (RAPD score), with additional RAPD scores recorded for each of a series of colored stimuli (blue, red, green, and yellow). The relationship between RAPD score and intereye differences (right minus left eye) in circumpapillary retinal nerve fiber layer (cpRNFL) thickness, mGCIPL, macular thickness, and SAP mean deviation (MD), was examined using linear regression. Results There was fair correlation between RAPD score and asymmetric macular structural damage measured by intereye difference in mGCIPL thickness (R2 = 0.285, P glaucoma. PMID:27064394

  6. [Fundus autofluorescence. Has it a place in the management of diabetic macular edema?

    Science.gov (United States)

    Zbiba, W; Baba, A; Bouayed, E; Daldoul, A

    2016-11-01

    Analyze the characteristics of fundus autofluorescence of diabetic macular edema and study the association between these characteristics and visual function. Our study included 18 patients (28 eyes) with clinically significant diabetic macular edema. All patients had a complete eye examination with a fundus autofluorescence imaging and optical coherence tomography. The central macular thickness and central macular volume were measured. The integrity of the inner segment-outer segment junction and the integrity of the external limiting membrane were also evaluated in the same area. Among the 28 eyes studied, 8 had normal autofluorescence. The remaining 20 eyes had abnormal autofluorescence: a hyper-cystoid autofluorescence in 5 eyes (25%), hyper-spot autofluorescence in 8 eyes (40%), and hypo-irregular autofluorescence in 5 eyes (25%). Best corrected visual acuity was significantly better in patients with normal autofluorescence and those with hyper-cystoid autofluorescence. There was no significant difference in central macular thickness (P=0.186) and central macular volume (P=0.191) between the four groups. The autofluorescence is a simple, fast, and non-invasive technique for the study of diabetic macular edema with good correlation to the visual function as well as to the extent of damage to the retina. It is, therefore, a possible alternative to other invasive imaging techniques in particular in the long term monitoring of diabetic macular edema. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Thickness and roughness measurements of nano thin films by interference

    Directory of Open Access Journals (Sweden)

    A Sabzalipour

    2011-06-01

    Full Text Available In the standard optical interference fringes approach, by measuring shift of the interference fringes due to step edge of thin film on substrate, thickness of the layer has already been measured. In order to improve the measurement precision of this popular method, the interference fringes intensity curve was extracted and analyzed before and after the step preparation. By this method, one can measure a few nanometers films thickness. In addition, using the interference fringes intensity curve and its fluctuations, the roughness of surface is measured within a few nanometers accuracy. Comparison of our results with some direct methods of thickness and roughness measurements, i.e. using surface profilemeter and atomic force microscopy confirms the accuracy of the suggested improvements.

  8. Comparison of phacoemulsification parameters effect on macular thickness changes after uneventful phacoemulsification in diabetic and non-diabetic patients

    Directory of Open Access Journals (Sweden)

    Ayse Gul Kocak Altintas

    2016-02-01

    Full Text Available AIM: To evaluate the effect of phacoemulsification(phacoparameters in micropulse phaco-tecnology with chamber stabilization environment(CASEand increased control and efficiency(ICEmode on central foveal thickness(CFTchanges after uneventful cataract surgery in normal and diabetic patients without retinopathy.METHODS: In this prospective study a total of 120 patients consist of 60 patients with type 2 diabetes mellitus as a diabetic group(DGwithout retinopathy and 60 normal subjects as a control group(CGwho underwent uneventful phaco were evaluated. Intraoperative phacoemulsification parameters including phaco time(PT, and effective phaco time(EPTwere recorded. The CFT measurements were performed preoperatively, at 1 and 3mo postoperatively. The CFT differences were calculated in each exam.RESULTS:The mean PT in DG was 1.40±0.43min and it was 1.44±0.32min in CG, the difference was not significant(P=0.85. The mean EPT was 20.12±8.82s and 19.24±9.02s in DG and CG respectively which was statistically insignificant(P=0.964. The mean preoperative CFT was 218.4±12.0 μm in DG and 222.1±16.6 μm in CG which was not statistically different(P=0.168. The mean increment of CFT in DG was 30.3±37.2 μm at 1mo postoperatively, while it was 13.1±12.5 μm in CG. Even the CFT increments were significant in both groups at 1mo postoperatively, it was statistically higher in DG than that of CG(P=0.001. The average CFT increment at 3mo postoperatively comparing to preoperative level was 12.5±12.4 μm and 4.6±9.7 μm in DG and CG respectively. The increment of CFT was significantly higher in DG than that of CG(P=0.00. But the comparison of the mean CFTs changes from postoperative 1mo and 3mo in both DG and CG, significant decrements were observed in each group(P=0.00 and P=0.03 respectively.CONCLUSION: The significant increment of CFT following uneventful phaco. With the similar phaco parameters were observed in both normal and diabetic subjects. The CFT

  9. Comparison of Different Approaches for Measuring Tibial Cartilage Thickness

    Directory of Open Access Journals (Sweden)

    Maier Jennifer

    2017-07-01

    Full Text Available Osteoarthritis is a degenerative disease affecting bones and cartilage especially in the human knee. In this context, cartilage thickness is an indicator for knee cartilage health. Thickness measurements are performed on medical images acquired in-vivo. Currently, there is no standard method agreed upon that defines a distance measure in articular cartilage. In this work, we present a comparison of different methods commonly used in literature. These methods are based on nearest neighbors, surface normal vectors, local thickness and potential field lines. All approaches were applied to manual segmentations of tibia and lateral and medial tibial cartilage performed by experienced raters. The underlying data were contrast agent-enhanced cone-beam C-arm CT reconstructions of one healthy subject’s knee. The subject was scanned three times, once in supine position and two times in a standing weight-bearing position. A comparison of the resulting thickness maps shows similar distributions and high correlation coefficients between the approaches above 0.90. The nearest neighbor method results on average in the lowest cartilage thickness values, while the local thickness approach assigns the highest values. We showed that the different methods agree in their thickness distribution. The results will be used for a future evaluation of cartilage change under weight-bearing conditions.

  10. [Comparative study of the effects of sterilized air and perfluoropropane gas tamponades on recovery after idiopathic full-thickness macular hole surgery].

    Science.gov (United States)

    He, F; Zheng, L; Dong, F T

    2017-05-11

    Objective: To compare the effects of sterilized air and perfluoropropane (C(3)F(8)) tamponades on recovery after vitrectomy for the treatment of idiopathic full-thickness macular hole (IFTMH). Methods: Case control study. Seventy-three eyes of 69 consecutive cases underwent vitrectomy with air (53 eyes) or 10% C(3)F(8) gas (20 eyes) tamponade. Surgical outcomes were retrospectively analyzed between the two groups, including logarithm of the minimal angle of resolution (logMAR) and optical coherence tomography findings like the size of the macular hole and the photoreceptor layer defect. Results: Preoperatively, the mean best corrected visual acuity (BCVA) was (0.10±0.49), the mean hole diameter was (777.9±320.7) μm, and the mean diameter of the photoreceptor layer defect was (1 709.3±516.0) μm in the sterilized air group, while in the C(3)F(8) group, the mean BCVA was (0.07±0.50), the mean hole diameter was (853.9±355.0) μm, and the mean defect diameter was (1 480.5±429.9) μm. The primary closure rate was 90.6% in the sterilized air group and 95.0% in the C(3)F(8) group. One month after surgery, the mean BCVA was (0.17±0.41), and the mean diameter of the photoreceptor layer defect was (820.5±598.0) μm in the sterilized air group, while in the C(3)F(8) group, the mean BCVA was 0.12±0.49, and the mean defect diameter was (762.5±658.0) μm. There was no statistically significant difference in the closure rate (χ(2)=0.019), BCVA ( t =-1.689), hole diameter ( t =0.837) and diameter of the photoreceptor layer defect ( t =0.338) between the two groups( P >0.05). Conclusions: Vitrectomy with sterilized air tamponade is safe and effective for the treatment of IFTMH and even cases with relatively large diameters. (Chin J Ophthalmol, 2017, 53: 327 - 331) .

  11. Evaluation of best corrected visual acuity and central macular thickness after intravitreal dexamethasone implant injections in patients with Irvine-Gass syndrome: A retrospective study of six cases.

    Science.gov (United States)

    Keilani, Chafik; Halalchi, Aziz; Wakpi Djeugue, Désiré; Regis, Anne; Abada, Samir

    2016-10-01

    Irvine-Gass syndrome is a macular edema (ME) that specifically occurs after cataract surgery. Its incidence varies from 0.2-2%. The purpose of this study is to evaluate the effectiveness of intravitreal dexamethasone implant injections in patients with Irvine-Gass syndrome. Patients with ME secondary to cataract surgery who underwent intravitreal injections of dexamethasone implant between December 2011 to October 2014 at François-Quesnay hospital (Mantes-la-Jolie, France) were retrospectively reviewed. The patients were followed for at least 10 months. All the patients were handled by intravitreal injection of dexamethasone in the eye of study among which some resisted to a preliminary treatment by non-steroidal anti-inflammatory drug (NSAID) and acetazolamide. The patients were examined each month. The patients were again handled by intravitreal injection of dexamethasone if they presented a recurrence. The primary endpoint of the study was determined on best corrected visual acuity (BCVA) using early diabetic retinopathy study (ETDRS) scale and central macular thickness (CMT) [μm] using optical coherence tomography (OCT) 3 and 6 months after the first injection. Secondary endpoints were the number of recurrences, the number of injections, the duration average before the first recurrence, the BCVA 10 months after the first injection and the tolerance. Six eyes of six patients were studied. At baseline, the mean (standard deviation [SD]) of the BCVA was 59.8±11. Three months after the first injection, the mean (SD) of the BCVA showed a statistically significant increase to 72.2±8.6 (P=0.03). Six months after the first injection, the mean (SD) of the BCVA showed a statistically significant increase to 72±11.8 (P=0.03). Concerning the CMT, the mean (SD) was 495.6±135.2 before treatment. Three months after the first injection, the mean (SD) of the CMT showed a statistically significant decrease to 268.6±57.8 (P=0.03). Six months after the first injection, the

  12. Metatarsophalangeal joint extension changes ultrasound measurements for plantar fascia thickness.

    Science.gov (United States)

    Granado, Michael J; Lohman, Everett B; Gordon, Keith E; Daher, Noha S

    2018-01-01

    Ultrasound is an inexpensive method for quantifying plantar fascia thickness, especially in those with plantar fasciitis. Ultrasound has also been used to assess the effectiveness of various treatments for plantar fasciitis by comparing plantar fascia thickness before and after an intervention period. While a plantar fascia thickness over 4 mm via ultrasound has been proposed to be consistent with plantar fasciitis, some researchers believe the 4 mm plantar fascia thickness level to be a dubious guideline for diagnosing plantar fasciitis due to the lack of standardization of the measurement process for plantar fascia thickness. In particular, no universal guidelines exist on the positioning of the metatarsophalangeal (MTP) joints during the procedure and the literature also has inconsistent protocols. The purpose of this study is to investigate and compare the influence of MTP joint extension on plantar fascia thickness in healthy participants and those with unilateral plantar fasciitis. The plantar fascia thickness of forty participants (20 with unilateral plantar fasciitis and 20 control) was measured via ultrasound three times at three different MTP joint positions: 1) at rest, 2) 30° of extension from the plantar surface, and 3) maximal extension possible. The plantar fascia became significantly thinner as MTP joint extension increased in both the plantar fasciitis group ( p  plantar fasciitis group, the involved plantar fascia was 1.2 to 1.3 mm thicker (p plantar fascia thickness between the two sides was less than 0.1 mm ( p  plantar fascia thickness. It is recommended that plantar fascia thickness measurements be performed with the toes at rest. If MTP joints must be extended, then the toes should be extended maximally and then noted to ensure subsequent ultrasound procedures are repeated. Standardizing the position of the MTP joints is not only important for attaining the most accurate thickness measurement of the plantar fascia, but is also

  13. Retinal vessel diameters decrease with macular ganglion cell layer thickness in autosomal dominant optic atrophy and in healthy subjects

    DEFF Research Database (Denmark)

    Rönnbäck, Cecilia; Grønskov, Karen; Larsen, Michael

    2014-01-01

    diameters (central retinal artery equivalent, CRAE, and central retinal vein equivalent, CRVE). Statistical analysis was corrected for age, gender, spherical equivalent refraction, axial length and mean arterial blood pressure (MABP) in a mixed model analysis. RESULTS: Retinal arteries and veins were...... ganglion cell-inner plexiform layer (GC-IPL) thickness (p = 0.0017 and p = 0.0057, respectively). CONCLUSION: Narrow retinal arteries and veins were associated not only with the severity of ADOA but with ganglion cell volume in patients with ADOA and in healthy subjects. This suggests that narrow vessels...

  14. Measurement of subcutaneous adipose tissue thickness by near-infrared

    International Nuclear Information System (INIS)

    Wang, Yu; Ying, Zeqiang; Hao, Dongmei; Zhang, Song; Yang, Yimin; Zeng, Yanjun

    2013-01-01

    Obesity is strongly associated with the risks of diabetes and cardiovascular disease, and there is a need to measure the subcutaneous adipose tissue (SAT) layer thickness and to understand the distribution of body fat. A device was designed to illuminate the body parts by near-infrared (NIR), measure the backscattered light, and predict the SAT layer thickness. The device was controlled by a single-chip microcontroller (SCM), and the thickness value was presented on a liquid crystal display (LCD). There were 30 subjects in this study, and the measurements were performed on 14 body parts for each subject. The paper investigated the impacts of pressure and skin colour on the measurement. Combining with principal component analysis (PCA) and support vector regression (SVR), the measurement accuracy of SAT layer thickness was 89.1 % with a mechanical caliper as reference. The measuring range was 5–11 mm. The study provides a non-invasive and low-cost technique to detect subcutaneous fat thickness, which is more accessible and affordable compared to other conventional techniques. The designed device can be used at home and in community.

  15. The thickness measuring methods by means of radionuclides

    International Nuclear Information System (INIS)

    Henker, W.

    1974-01-01

    The thickness measuring devices RMM 24004 produced in German Democratic Republic are described. They consist of measuring probe and central unit. The measuring probe contains radiator and measuring head, which consists of radiation detector and electrometric amplifier. They utilize absorption or backscattering of 147 Pm, 85 Kr, 90 Sr/ 90 Y, 106 Ru/ 106 Rh or 137 Cs radiation in interaction with atoms of measured material. A survey of typical applications is given. (Z.M.)

  16. Thickness measurement instrument with memory storage of multiple calibrations

    International Nuclear Information System (INIS)

    Lieber, S.; Schlesinger, J.; Lieber, D.; Baker, A.

    1979-01-01

    An improved backscatter instrument for the nondestructive measurement of coatings on a substrate is described. A memory having selectable memory areas, each area having stored intelligence available which is determinative of the shape of a functional plot of coating thickness versus backscatter counts per minute unique for each particular combination of emitting isotope, substrate material, coating material and physical characteristics of the measuring instrument. A memory selector switch connects a selected area of memory to a microprocessor operating under program control whereby the microprocessor reads the intelligence stored at the selected area and converts the backscattered count of the coating being measured into indicia of coating thickness

  17. Measurement of compressed breast thickness by optical stereoscopic photogrammetry.

    Science.gov (United States)

    Tyson, Albert H; Mawdsley, Gordon E; Yaffe, Martin J

    2009-02-01

    The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of the breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.

  18. Thickness of the retinal photoreceptor outer segment layer in healthy volunteers and in patients with diabetes mellitus without retinopathy, diabetic retinopathy, or diabetic macular edema

    Directory of Open Access Journals (Sweden)

    Abdullah Ozkaya

    2017-04-01

    Conclusion: The PROS layer at the foveal center was thinner in patients who had diabetic retinopathy or diabetic macular edema than both the healthy volunteers and diabetic patients without retinopathy.

  19. Age, sex, and type of medication predict the effect of anti-VEGF treatment on central retinal thickness in wet age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Bek T

    2018-03-01

    Full Text Available Toke Bek, Sidsel Ehlers Klug Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark Purpose: Randomized clinical trials studying the effects of VEGF inhibition on wet age-related macular degeneration (wAMD are designed so that the effects of individually varying risk factors on the treatment response are eliminated. The influence of these risk factors can be studied in large data sets from real-life experience.Patients and methods: All 2,255 patients diagnosed with wAMD requiring anti-VEGF treatment in at least one eye over more than 9 years in a defined Danish population with 0.9 million inhabitants were studied. The predictive value of eye laterality, sex, current smoking status, type of anti-VEGF compound, membrane position, membrane type, leakage area, number of injections, number of visits, age, time to follow-up, visual acuity, and central retinal thickness (CRT at baseline on change in CRT after three monthly injections with anti-VEGF compound followed by treatment pro re nata for up to 12 months was assessed.Results: After 12 months, 67 patients had died, 903 had had stable CRT for at least 6 months, and 1,285 patients had not achieved stable CRT. The reduction in CRT was -84.8±118.3 µm, whereas the increase in visual acuity was 2.2±14.7 Early Treatment Diabetic Retinopathy Study letters. The risk factors included contributed to 64% of the variation in CRT reduction. High age and high CRT at baseline predicted high CRT reduction, whereas more injections, treatment with ranibizumab, and male sex predicted a low CRT reduction.Conclusion: Age, sex, and type of anti-VEGF medication can be used to plan treatment and inform patients about the expected response of anti-VEGF treatment in wAMD. Keywords: wet AMD, anti-VEGF treatment, risk factors, real-life experience 

  20. Reliability of Heterochromatic Flicker Photometry in Measuring Macular Pigment Optical Density among Preadolescent Children

    Directory of Open Access Journals (Sweden)

    Sasha M. McCorkle

    2015-10-01

    Full Text Available Macular pigment optical density (MPOD—assessed using customized heterochromatic flicker photometry (cHFP—is related to better cognition and brain lutein among adults. However, the reliability of MPOD assessed by cHFP has not been investigated in children. We assessed inter-session reliability of MPOD using modified cHFP. 7–10-year-olds (n = 66 underwent cHFP over 2 visits using 11 examiners. Reliability was also assessed in a subsample (n = 46 with only 2 examiners. Among all participants, there was no significant difference between the two sessions (p = 0.59—session 1: 0.61 ± 0.28; session 2: 0.62 ± 0.27. There was no significant difference in the MPOD of boys vs. girls (p = 0.56. There was a significant correlation between sessions (Y = 0.52x + 0.31; R2 = 0.29, p ≤ 0.005, with a reliability of 0.70 (Cronbach’s α. Among the subsample with 2 examiners, there was a significant correlation between sessions (Y = 0.54x + 0.31; R2 = 0.32, p < 0.005, with a reliability of 0.72 (Cronbach’s α. In conclusion, there is moderate reliability for modified cHFP to measure MPOD in preadolescents. These findings provide support for future studies aiming to conduct noninvasive assessments of retinal xanthophylls and study their association with cognition during childhood.

  1. Measurement of Retinal Sensitivity on Tablet Devices in Age-Related Macular Degeneration.

    Science.gov (United States)

    Wu, Zhichao; Guymer, Robyn H; Jung, Chang J; Goh, Jonathan K; Ayton, Lauren N; Luu, Chi D; Lawson, David J; Turpin, Andrew; McKendrick, Allison M

    2015-06-01

    We compared measurements of central retinal sensitivity on a portable, low-cost tablet device to the established method of microperimetry in age-related macular degeneration (AMD). A customized test designed to measure central retinal sensitivity (within the central 1° radius) on a tablet device was developed using an open-source platform called PsyPad. A total of 30 participants with AMD were included in this study, and all participants performed a practice test on PsyPad, followed by four tests of one eye and one test of the other eye. Participants then underwent standardized microperimetry examinations in both eyes. The average test duration on PsyPad was 53.9 ± 7.5 seconds, and no significant learning effect was observed over the examinations performed ( P = 1.000). The coefficient of repeatability of central retinal sensitivity between the first two examinations on PsyPad was ±1.76 dB. The mean central retinal sensitivity was not significantly different between PsyPad (25.7 ± 0.4 dB) and microperimetry (26.1 ± 0.4 dB, P = 0.094), and the 95% limits of agreement between the two measures were between -4.12 and 4.92 dB. The measurements of central retinal sensitivity can be performed effectively using a tablet device, displaying reasonably good agreement with those obtained using the established method of microperimetry. These findings highlight the potential of tablet devices as low-cost and portable tools for developing and performing visual function measures that can be easily and widely implemented.

  2. High-precision thickness measurements using beta backscatter

    International Nuclear Information System (INIS)

    Heckman, R.V.

    1978-11-01

    A two-axis, automated fixture for use with a high-intensity Pm-147 source and a photomultiplier-scintillation beta-backscatter probe for making thickness measurements has been designed and built. A custom interface was built to connect the system to a minicomputer, and software was written to position the tables, control the probe, and make the measurements. Measurements can be made in less time with much greater precision than by the method previously used

  3. Biomedical sensor for transcutaneous oxygen measurements using thick film technology

    OpenAIRE

    Lam, Yu-Zhi (Liza)

    2003-01-01

    The measurement of the partial pressure of oxygen in arterial blood is essential for the analysis of a patient's respiratory condition. There are several commercially available methods and systems to measure this parameter transcutaneously. However, they tend to be cumbersome and costly. To overcome the disadvantages presented, a new type of sensor for transcutaneous blood gas measurement was investigated, employing thick film technology, which is an excellent technique to produce sensors in ...

  4. Ice thickness measurements and volume estimates for glaciers in Norway

    Science.gov (United States)

    Andreassen, Liss M.; Huss, Matthias; Melvold, Kjetil; Elvehøy, Hallgeir; Winsvold, Solveig H.

    2014-05-01

    Whereas glacier areas in many mountain regions around the world now are well surveyed using optical satellite sensors and available in digital inventories, measurements of ice thickness are sparse in comparison and a global dataset does not exist. Since the 1980s ice thickness measurements have been carried out by ground penetrating radar on many glaciers in Norway, often as part of contract work for hydropower companies with the aim to calculate hydrological divides of ice caps. Measurements have been conducted on numerous glaciers, covering the largest ice caps as well as a few smaller mountain glaciers. However, so far no ice volume estimate for Norway has been derived from these measurements. Here, we give an overview of ice thickness measurements in Norway, and use a distributed model to interpolate and extrapolate the data to provide an ice volume estimate of all glaciers in Norway. We also compare the results to various volume-area/thickness-scaling approaches using values from the literature as well as scaling constants we obtained from ice thickness measurements in Norway. Glacier outlines from a Landsat-derived inventory from 1999-2006 together with a national digital elevation model were used as input data for the ice volume calculations. The inventory covers all glaciers in mainland Norway and consists of 2534 glaciers (3143 glacier units) covering an area of 2692 km2 ± 81 km2. To calculate the ice thickness distribution of glaciers in Norway we used a distributed model which estimates surface mass balance distribution, calculates the volumetric balance flux and converts it into thickness using the flow law for ice. We calibrated this model with ice thickness data for Norway, mainly by adjusting the mass balance gradient. Model results generally agree well with the measured values, however, larger deviations were found for some glaciers. The total ice volume of Norway was estimated to be 275 km3 ± 30 km3. From the ice thickness data set we selected

  5. Dynamic-speckle profilometer for online measurements of coating thickness

    Energy Technology Data Exchange (ETDEWEB)

    Kamshilin, A A [Laboratory of Optical Sensor Technology, Department of Physics, University of Kuopio, PO Box 1627, FIN-70211 Kuopio (Finland); Semenov, D V [Laboratory of Optical Sensor Technology, Department of Physics, University of Kuopio, PO Box 1627, FIN-70211 Kuopio (Finland); Nippolainen, E [Laboratory of Optical Sensor Technology, Department of Physics, University of Kuopio, PO Box 1627, FIN-70211 Kuopio (Finland); Miridonov, S [Optics Department, CICESE, Carr. Tijuana-Ensenada km 107, C.P. 22860, A.P. 360, Ensenada, B.C. (Mexico)

    2007-10-15

    Online control of thickness of as-deposited coatings is of great importance because it directly affects the quality of protective coatings. We present a novel approach that enables online, real-time and non-contact measurements thickness of thermally sprayed coatings. The proposed technique uses dynamic speckles generated by rapidly deflecting laser beam. Within 10 ms the system can scan 500 times a small area of the deposited layer thus resulting in measurement accuracy of 5 microns irrespectively of the layer roughness. In comparison with traditional optical triangulation technique of distance measurements, our system has following advantages: (i) much simpler optical scheme that includes conventional photodiode to measure the scattered light, (ii) much simpler electronics for real-time data processing, (iii) much higher speed of measurements.

  6. Dynamic-speckle profilometer for online measurements of coating thickness

    International Nuclear Information System (INIS)

    Kamshilin, A A; Semenov, D V; Nippolainen, E; Miridonov, S

    2007-01-01

    Online control of thickness of as-deposited coatings is of great importance because it directly affects the quality of protective coatings. We present a novel approach that enables online, real-time and non-contact measurements thickness of thermally sprayed coatings. The proposed technique uses dynamic speckles generated by rapidly deflecting laser beam. Within 10 ms the system can scan 500 times a small area of the deposited layer thus resulting in measurement accuracy of 5 microns irrespectively of the layer roughness. In comparison with traditional optical triangulation technique of distance measurements, our system has following advantages: (i) much simpler optical scheme that includes conventional photodiode to measure the scattered light, (ii) much simpler electronics for real-time data processing, (iii) much higher speed of measurements

  7. Occult Macular Dystrophy

    Directory of Open Access Journals (Sweden)

    Işıl Sayman Muslubaş

    2016-04-01

    Full Text Available Occult macular dystrophy is an inherited macular dystrophy characterized by a progressive decline of bilateral visual acuity with normal fundus appearance, fluorescein angiogram and full-field electroretinogram. This case report presents a 20-year-old female patient with bilateral progressive decline of visual acuity for six years. Her visual acuity was 3-4/10 in both eyes. Anterior segment and fundus examination, fluorescein angiogram and full-field electroretinogram were normal. She could read all Ishihara pseudoisochromatic plates. Fundus autofluorescence imaging was normal. There was a mild central hyporeflectance on fundus infrared reflectance imaging in both eyes. Reduced foveal thickness and alterations of the photoreceptor inner and outer segment junction were observed by optical coherence tomography in both eyes. Central scotoma was also found by microperimetry and reduced central response was revealed by multifocal electroretinogram in both eyes. These findings are consistent with the clinical characteristics of occult macular dystrophy

  8. Development of sea water pipe thickness measurement technique

    International Nuclear Information System (INIS)

    Morimoto, Kazuo; Wakayama, Seiichi; Takeuchi, Iwao; Masamori, Sigero; Yamasita, Takesi.

    1995-01-01

    In nuclear and thermal power plants, wall wear of sea water pipes is reported to occur in the inner surface due to corrosion and erosion. From the viewpoint of improving the equipments reliability, it is desirable that wall thickness should be measured from the outer surface of the pipe during operation. In the conventional method, paint on the outer surface of the pipe was locally removed at each point of a 20 by 50 mm grid, and inspection was carried out at these spots. However, this method had some problems, such as (1) it was necessary to replace the paint, and (2) it was difficult to obtain the precise distribution of wall thickness. Therefore, we have developed a wall thickness measuring system which has the following features. (1) It is possible to perform inspection from the outer surface without removing paint during operation. (2) It is possible to measure the distribution of wall thickness and display it as color contour map simultaneously. (3) The work of inspectors can be alleviated by the automatic recording of measured data. (author)

  9. Apparatus for measuring profile thickness of strip material

    International Nuclear Information System (INIS)

    Hold, A.C.

    1982-01-01

    Apparatus for measuring the thickness profile of steel strip comprises a radiation source reciprocally movable in a stepwise fashion (by a belt) across the strip width on one side thereof and a single elongated detector on the other side of the strip aligned with the scanning source. This detector may be a fluorescent scintillator detector or an ionisation chamber. Means are provided for sensing the degree of excitation in the detector in synchronism with the scanning source whereby to provide an output representative of the thickness profile of the strip. (author)

  10. Oxide thickness measurement for monitoring fuel performance at high burnup

    International Nuclear Information System (INIS)

    Jaeger, M.A.; Van Swam, L.F.P.; Brueck-Neufeld, K.

    1991-01-01

    For on-site monitoring of the fuel performance at high burnup, Advanced Nuclear Fuels uses the linear scan eddy current method to determine the oxide thickness of irradiated Zircaloy fuel cans. Direct digital data acquisition methods are employed to collect the data on magnetic storage media. This field-proven methodology allows oxide thickness measurements and rapid interpretation of the data during the reactor outages and makes it possible to immediately reinsert the assemblies for the next operating cycle. The accuracy of the poolside measurements and data acquisition/interpretation techniques have been verified through hot cell metallographic measurements of rods previously measured in the fuel pool. The accumulated data provide a valuable database against which oxide growth models have been benchmarked and allow for effective monitoring of fuel performance. (orig.) [de

  11. Pigmentos maculares Macular pigments

    Directory of Open Access Journals (Sweden)

    Renata Canovas

    2009-12-01

    Full Text Available A luteína e a zeaxantina são pigmentos amarelos que se localizam na mácula. Devido à sua localização, diminuem e filtram a quantidade de luz principalmente azul que chega aos fotorreceptores, atuam como antioxidantes e podem melhorar a qualidade visual. Esta é uma revisão do seu mecanismo de incorporação, ação, possíveis aplicações e conhecimento científico a respeito.Lutein and Zeaxanthin are yellow pigments located at the macula. Because of your location macular pigments decrease and filter the amount of blue light that reach photoreceptors, protect the outer retina from oxidative stress and may improve the vision quality. This is a review regarding incorporation mechanism, function and knowledge update.

  12. A comparison of two methods to measure choroidal thickness by enhanced depth imaging optical coherence tomography

    DEFF Research Database (Denmark)

    Lundberg, Lars Kristian; Vestergaard, Anders Højslet; Vergmann, Anna Stage

    Introduction The choroid is believed to be involved in the pathophysiology of several vision threatening diseases such as age-related macular degeneration, central serous chorioretinopathy, inflammatory disorders and myopic macular degeneration. Enhanced depth imaging spectral-domain optical...... millimeter in each direction of fovea. Only the horizontal and vertical sections were selected for analysis. A total of 9 targets per eye that represented anatomically different choroidal locations were analysed for every subject. We used 2 different methods from the Heidelberg Explorer software to measure...

  13. Backscattering measurement device for measuring the thickness of a layer

    International Nuclear Information System (INIS)

    Weinstock, J.; Lieber, D.; Hay, W.D.

    1978-01-01

    There is provided for a measuring wheel on the run of which backscattering probes are mounted, serving for irradiation and measurement of the radiation reflected from a strip of substrate tape coated e.g. with Au. The probes are of the model HH-3 of Unit Process Assemblies Inc. The material strip is guided on the outside of the wheel run. The measuring wheel is rotating with such speed that the tangential velocity of a point on the run is equal to the speed of the strip. Therefore the movement of the strip need not be stopped during measurement (on-line measurement). (DG) [de

  14. Highly accurate adaptive TOF determination method for ultrasonic thickness measurement

    Science.gov (United States)

    Zhou, Lianjie; Liu, Haibo; Lian, Meng; Ying, Yangwei; Li, Te; Wang, Yongqing

    2018-04-01

    Determining the time of flight (TOF) is very critical for precise ultrasonic thickness measurement. However, the relatively low signal-to-noise ratio (SNR) of the received signals would induce significant TOF determination errors. In this paper, an adaptive time delay estimation method has been developed to improve the TOF determination’s accuracy. An improved variable step size adaptive algorithm with comprehensive step size control function is proposed. Meanwhile, a cubic spline fitting approach is also employed to alleviate the restriction of finite sampling interval. Simulation experiments under different SNR conditions were conducted for performance analysis. Simulation results manifested the performance advantage of proposed TOF determination method over existing TOF determination methods. When comparing with the conventional fixed step size, and Kwong and Aboulnasr algorithms, the steady state mean square deviation of the proposed algorithm was generally lower, which makes the proposed algorithm more suitable for TOF determination. Further, ultrasonic thickness measurement experiments were performed on aluminum alloy plates with various thicknesses. They indicated that the proposed TOF determination method was more robust even under low SNR conditions, and the ultrasonic thickness measurement accuracy could be significantly improved.

  15. Computer vision based nacre thickness measurement of Tahitian pearls

    Science.gov (United States)

    Loesdau, Martin; Chabrier, Sébastien; Gabillon, Alban

    2017-03-01

    The Tahitian Pearl is the most valuable export product of French Polynesia contributing with over 61 million Euros to more than 50% of the total export income. To maintain its excellent reputation on the international market, an obligatory quality control for every pearl deemed for exportation has been established by the local government. One of the controlled quality parameters is the pearls nacre thickness. The evaluation is currently done manually by experts that are visually analyzing X-ray images of the pearls. In this article, a computer vision based approach to automate this procedure is presented. Even though computer vision based approaches for pearl nacre thickness measurement exist in the literature, the very specific features of the Tahitian pearl, namely the large shape variety and the occurrence of cavities, have so far not been considered. The presented work closes the. Our method consists of segmenting the pearl from X-ray images with a model-based approach, segmenting the pearls nucleus with an own developed heuristic circle detection and segmenting possible cavities with region growing. Out of the obtained boundaries, the 2-dimensional nacre thickness profile can be calculated. A certainty measurement to consider imaging and segmentation imprecisions is included in the procedure. The proposed algorithms are tested on 298 manually evaluated Tahitian pearls, showing that it is generally possible to automatically evaluate the nacre thickness of Tahitian pearls with computer vision. Furthermore the results show that the automatic measurement is more precise and faster than the manual one.

  16. Imaging and thickness measurement of amorphous intergranular films using TEM

    International Nuclear Information System (INIS)

    MacLaren, I.

    2004-01-01

    Fresnel fringe analysis is shown to be unreliable for grain boundaries in yttrium-doped alumina: the determined thicknesses do not agree well with those measured from high resolution transmission electron microscopy (HRTEM), the asymmetry between under- and overfocus is very large, and Fresnel fringes are sometimes shown at boundaries which contain no amorphous film. An alternative approach to the analysis of HRTEM images of grain boundary films is demonstrated: Fourier filtering is used to remove the lattice fringes from the image thereby significantly enhancing the visibility of the intergranular films. The apparent film thickness shows a discrepancy between measurements from the original HRTEM image and the filtered image. It was shown that fringe delocalisation and diffuseness of the amorphous/crystalline interfaces will lead to a significant underestimate of the thickness in unprocessed HRTEM images. In contrast to this, the average thickness can be much more accurately measured from the Fourier-filtered image, provided the boundary is oriented accurately edge-on

  17. Sensor for thickness measurement of a liquid metal film

    International Nuclear Information System (INIS)

    Blanc, R.

    1984-04-01

    Description, calibration and measuring method of a sensor for the measure of thin liquid metal depths in a temperature range of 0-500 0 C and for shift frequencies from 0 to 100 Hz; these sensors are based on the principle of induction-coil impedance variation, as a function of the thickness of an electrical conductor matter placed in the coil magnetic field [fr

  18. Intravitreal gas injection for the treatment of diabetic macular edema

    Directory of Open Access Journals (Sweden)

    McHugh D

    2011-10-01

    Full Text Available Dominic McHugh, Bhaskar Gupta, Manzar Saeed King's College Hospital, Denmark Hill, London, England, UK Purpose: This study investigates the efficacy of an intravitreal gas injection in inducing a posterior vitreous detachment (PVD in patients with clinically significant diabetic macular edema refractory to laser therapy. Methods: A local ethics committee-approved technique of an intravitreal injection of pure perfluoropropane gas (C3F8 was performed for all participants. After a period of prone positioning, the patients underwent regular and detailed clinical review. Main outcome measures: The induction of a PVD, change in macular thickness, change in visual acuity. Results: A PVD was induced in all five eyes with subsequent signs of reduction in macular thickness and resolution of exudates. Mean visual improvement was 11 ETDRS (Early Treatment Diabetic Retinopathy Study letters (range 4–21. Apart from a transient vitreous hemorrhage in one eye, there were no significant treatment-related complications. Conclusion: The induction of a PVD by pneumatic retinopexy appears to have a significant influence on diabetic macular edema in eyes which have not successfully responded to macular laser therapy. A randomized clinical trial is justified on the basis of the initial promising data. Keywords: optical coherence tomography, OCT, posterior vitreous detachment, perfluoropropane

  19. Increased-resolution OCT thickness mapping of the human macula: a statistically based registration.

    Science.gov (United States)

    Bernardes, Rui; Santos, Torcato; Cunha-Vaz, José

    2008-05-01

    To describe the development of a technique that enhances spatial resolution of retinal thickness maps of the Stratus OCT (Carl Zeiss Meditec, Inc., Dublin, CA). A retinal thickness atlas (RT-atlas) template was calculated, and a macular coordinate system was established, to pursue this objective. The RT-atlas was developed from principal component analysis of retinal thickness analyzer (RTA) maps acquired from healthy volunteers. The Stratus OCT radial thickness measurements were registered on the RT-atlas, from which an improved macular thickness map was calculated. Thereafter, Stratus OCT circular scans were registered on the previously calculated map to enhance spatial resolution. The developed technique was applied to Stratus OCT thickness data from healthy volunteers and from patients with diabetic retinopathy (DR) or age-related macular degeneration (AMD). Results showed that for normal, or close to normal, macular thickness maps from healthy volunteers and patients with DR, this technique can be an important aid in determining retinal thickness. Efforts are under way to improve the registration of retinal thickness data in patients with AMD. The developed technique enhances the evaluation of data acquired by the Stratus OCT, helping the detection of early retinal thickness abnormalities. Moreover, a normative database of retinal thickness measurements gained from this technique, as referenced to the macular coordinate system, can be created without errors induced by missed fixation and eye tilt.

  20. Evaluation of Macular Ganglion Cell-inner Plexiform Layer and Choroid in Psoriasis Patients Using Enhanced Depth Imaging Spectral Domain Optical Coherence Tomography.

    Science.gov (United States)

    Ersan, Ismail; Kilic, Sevilay; Arikan, Sedat; Kara, Selcuk; Işik, Selda; Gencer, Baran; Ogretmen, Zerrin

    2017-08-01

    To evaluate changes in the thickness of the central macula, macular ganglion cell-inner plexiform layer (mGCIPL), and subfoveal choroid in patients with psoriasis using spectral domain optical coherence tomography (SD-OCT). The measurements of macular, mGCIPL thicknesses and subfoveal choroidal thickness (SFCT) obtained by SD-OCT of psoriasis patients (n = 46). These measurements were compared with those of 50 healthy controls. The macular, mGCIPL, and choroidal thicknesses did not differ between the controls and psoriatic subjects (p>0.05). When the patients were divided into two distinct groups, only the SFCT was significantly thicker in the severe psoriasis group compared with the mild psoriasis group (p = 0.003). These findings suggest that choroidal alterations are seen without macular changes in patients with psoriasis. Severe psoriasis appears to be related to increases in SFCT as a consequence of possible inflammatory cascades that are part of the disease's pathogenesis.

  1. Layer thickness measurement using the X-ray fluorescence principle

    International Nuclear Information System (INIS)

    Mengelkamp, B.

    1980-01-01

    Curium 244 having a gamma energy of about 15.5 keV is used as excitation emitter for contactless and continuous measuring of the thickness of metallic layers on iron strip. Soft gamma radiation is absorbed in matter according to the photo effect, so that X-ray fluorescence radiation is generated in the matter, which depends on the element and is radiated to all sides. For instance, it amounts for iron 6.4 keV and is measured with a specific ionisation chamber for this energy range. With increasing atomic number of the elements, the energy of fluorescence radiation increases and hence also the emission signal of the detector. The prerequisite for a usable measuring effect is an element distance of at least two and the thickness of the layer to be measured being in an optimum range. A signal dependent on the thickness of the layer is produced either by absorption of iron radiation (absorption method - aluminium and tin) or by build-up radiation of the material of the layer (emission method - zinc and lead). (orig./GSCH) [de

  2. DNA Measurement of Overlapping Cell Nuclei in Thick Tissue Sections

    Directory of Open Access Journals (Sweden)

    Liang Ji

    1997-01-01

    Full Text Available The paper describes an improved image analysis procedure for measuring the DNA content of cell nuclei in thick sections of liver tissue by absorption densitometry. Whereas previous methods only permitted the analysis of isolated nuclei, the new technique enables both isolated and overlapping nuclei to be measured. A 3D segmentation procedure determines whether each object is an isolated nucleus or a pair of overlapping nuclei; in the latter case the combined optical density is redistributed to the individual nuclei. A selection procedure ensures that only complete nuclei are measured.

  3. MEASUREMENT OF RNFL THICKNESS USING OCT IMAGES FOR GLAUCOMA DETECTION

    Directory of Open Access Journals (Sweden)

    Dhivyabharathi

    2013-08-01

    Full Text Available The thickness of retinal nerve fiber layer (RNFL is one of the pompous parameters for assessing the disease, Glaucoma. A substantial amount of vision can be lost before the patient becomes aware of any defect. Optical Coherence Tomography (OCT provides enhanced depth and clarity of viewing tissues with high resolution compared with other medical imaging devices. It examines the living tissue non-invasively. This paper presents an automatic method to find the thickness of RNFL using OCT images. The proposed algorithm first extracts all the layers present in the OCT image by texture segmentation using Gabor filter method and an algorithm is then developed to segment the RNFL. The thickness measurement of RNFL is automatically displayed based on pixel calculation. The calculated thickness values are compared with the original values obtained from hospital. The result shows that the proposed algorithm is efficient in segmenting the region of interest without manual intervention. The effectiveness of the proposed method is proved statistically by the performance analysis.

  4. Measurement Of Lead Equivalent Thickness For Irradiation Room: An Analysis

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Azuhar Ripin; Husaini Salleh; Mohd Khairusalih Mohd Zin; Muhammad Jamal Muhd Isa; Mohd Faizal Abdul Rahman

    2014-01-01

    The Malaysian Ministry of Health (MOH) has established that the irradiation room must have a sufficient thickness of shielding to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for irradiation room at health clinics own by MOH. Results of measurement of 8 irradiation rooms conducted in 2014 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that almost all the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  5. INTERNAL LIMITING MEMBRANE PEELING VERSUS INVERTED FLAP TECHNIQUE FOR TREATMENT OF FULL-THICKNESS MACULAR HOLES: A COMPARATIVE STUDY IN A LARGE SERIES OF PATIENTS.

    Science.gov (United States)

    Rizzo, Stanislao; Tartaro, Ruggero; Barca, Francesco; Caporossi, Tomaso; Bacherini, Daniela; Giansanti, Fabrizio

    2017-12-08

    The inverted flap (IF) technique has recently been introduced in macular hole (MH) surgery. The IF technique has shown an increase of the success rate in the case of large MHs and in MHs associated with high myopia. This study reports the anatomical and functional results in a large series of patients affected by MH treated using pars plana vitrectomy and gas tamponade combined with internal limiting membrane (ILM) peeling or IF. This is a retrospective, consecutive, nonrandomized comparative study of patients affected by idiopathic or myopic MH treated using small-gauge pars plana vitrectomy (25- or 23-gauge) between January 2011 and May 2016. The patients were divided into two groups according to the ILM removal technique (complete removal vs. IF). A subgroup analysis was performed according to the MH diameter (MH peeling and 320 patients underwent pars plana vitrectomy and IF. Overall, 84.94% of the patients had complete anatomical success characterized by MH closure after the operation. In particular, among the patients who underwent only ILM peeling the closure rate was 78.75%; among the patients who underwent the IF technique, it was 91.93% (P = 0.001); and among the patients affected by full-thickness MH ≥400 µm, success was achieved in 95.6% of the cases in the IF group and in 78.6% in the ILM peeling group (P = 0.001); among the patients with an axial length ≥26 mm, success was achieved in 88.4% of the cases in the IF group and in 38.9% in the ILM peeling group (P = 0.001). Average preoperative best-corrected visual acuity was 0.77 (SD = 0.32) logarithm of the minimum angle of resolution (20/118 Snellen) in the peeling group and 0.74 (SD = 0.33) logarithm of the minimum angle of resolution (20/110 Snellen) in the IF group (P = 0.31). Mean postoperative best-corrected visual acuity was 0.52 (SD = 0.42) logarithm of the minimum angle of resolution (20/66 Snellen) in the peeling group and 0.43 (SD = 0.31) logarithm of the minimum angle of resolution (20

  6. X-ray thickness measurement of aluminum alloys

    International Nuclear Information System (INIS)

    Albert, J.J.

    1976-01-01

    The theory of x-ray thickness gauging is extended to reveal the conditions under which a fixed anode voltage is ideal. A mathematical model of an alloy and computations reveal that two voltages can be used to measure the aluminum alloys with an error of roughly 1 percent, determined by the tolerance on manganese content rather than the large errors ordinarily a consequence of the tolerances on copper and zinc content. Implementation is discussed

  7. Application of OCT in traumatic macular hole

    Directory of Open Access Journals (Sweden)

    Wen-Li Fu

    2017-12-01

    Full Text Available AIM: To observe the application of optical coherence tomography(OCTin the diseases of traumatic macular hole. METHODS: Twenty-five eyes of 23 patients with traumatic macular hole from January 2015 to January 2017 were enrolled in this study, including 9 eyes treated without surgeries, 16 eyes with surgeries. The image features were analyzed using OCT from ZEISS. RESULTS: The OCT characteristics in patients with traumatic macular hole were partial or full-thickness disappearance of the neuro-epithelium. Posterior vitreous detachment was not seen in the traumatic macular hole. OCT examination revealed that 4 eyes had partial detachment of macular hole and 21 eyes had full thickness detachment. Of the twenty-one eyes, 4 eyes had simple macular hole, 10 eyes had macular full-layer division with peripheral nerve epithelium edema, 7 eyes had the macular full-layer hole with the neuro-epithelium localized detachment. In the 25 eyes, 9 eyes did not undergo the surgery, of which 7 eyes were self-healing; 16 eyes were surgically treated. Postoperative OCT showed the macular structure were normal in 12 eyes with the visual acuity improved 3 lines; retinal nerve epithelium were thinning in 4 eyes, visual acuities were not significant improved after surgery. CONCLUSION: OCT examination is necessary for the diagnosis and treatment of traumatic macular hole.

  8. Refining enamel thickness measurements from B-mode ultrasound images.

    Science.gov (United States)

    Hua, Jeremy; Chen, Ssu-Kuang; Kim, Yongmin

    2009-01-01

    Dental erosion has been growing increasingly prevalent with the rise in consumption of heavy starches, sugars, coffee, and acidic beverages. In addition, various disorders, such as Gastroenterological Reflux Disease (GERD), have symptoms of rapid rates of tooth erosion. The measurement of enamel thickness would be important for dentists to assess the progression of enamel loss from all forms of erosion, attrition, and abrasion. Characterizing enamel loss is currently done with various subjective indexes that can be interpreted in different ways by different dentists. Ultrasound has been utilized since the 1960s to determine internal tooth structure, but with mixed results. Via image processing and enhancement, we were able to refine B-mode dental ultrasound images for more accurate enamel thickness measurements. The mean difference between the measured thickness of the occlusal enamel from ultrasound images and corresponding gold standard CT images improved from 0.55 mm to 0.32 mm with image processing (p = 0.033). The difference also improved from 0.62 to 0.53 mm at the buccal/lingual enamel surfaces, but not significantly (p = 0.38).

  9. What Is Macular Edema?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis ... Macular Edema Sections What Is Macular Edema? What Causes Macular Edema? Macular ...

  10. Macular degeneration

    Science.gov (United States)

    The macula is the part of the retina that distinguishes fine details at the center of the field of vision. Macular degeneration results from a partial breakdown of the insulating layer between the retina and the choroid layer of ...

  11. What Is Macular Edema?

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Macular Edema Sections What Is Macular Edema? What Causes Macular ... Edema Diagnosis Macular Edema Treatment What Is Macular Edema? Leer en Español: ¿Qué es un edema macular? ...

  12. What Is Macular Edema?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Macular Edema Sections What Is Macular Edema? What Causes Macular ... Edema Diagnosis Macular Edema Treatment What Is Macular Edema? Leer en Español: ¿Qué es un edema macular? ...

  13. Measurement of the thickness of the bronchial epithelium

    International Nuclear Information System (INIS)

    Bowden, D.H.; Baldwin, F.

    1989-02-01

    Cancer of the lung in uranium miners is thought to be related to the inhalation of gaseous radon daughters which become attached to molecules of water vapour or to dust particles. Since, the depth of tissue penetration by alpha particles is short, the thickness of the epithelium that lines the bronchial tree may be a critical factor in the development of cancers at specific sites in the lung. The objectives of the present study were: 1) to measure the thickness of human bronchial epithelium; 2) to determine the distribution and depth of the nuclei of basal cells in the bronchial epithelium; and 3) to compare these parameters in groups of smokers and non-smokers. Twenty-nine surgically removed specimens of the lung were examined (26 smokers, 3 non-smokers). The specimens were fixed and prepared for examination by light and electron microscopy. Blocks of tissue were oriented so that the maximum number of bronchi were cut in cross-section; measurements included bronchi of all sizes from bronchial generations (1≥ 9.01 mm) diameter to the smallest bronchioles, generations 7 - 16 (0.26 - 2.0 mm). Comparison of measurements in smokers and non-smokers show no significant differences, so that the 29 cases are considered to represent a homogeneous group. With progressive divisions of the bronchi, the epithelium decreases in thickness. Of more importance are the figures relating to the distance from the cell surface to the underlying nucleus. Here too, with the exception of goblet cells, the measurements are significantly smaller in generations 7 - 16 than in generation 1

  14. Diagnostic Accuracy of Spectralis SD OCT Automated Macular Layers Segmentation to Discriminate Normal from Early Glaucomatous Eyes.

    Science.gov (United States)

    Pazos, Marta; Dyrda, Agnieszka Anna; Biarnés, Marc; Gómez, Alicia; Martín, Carlos; Mora, Clara; Fatti, Gianluca; Antón, Alfonso

    2017-08-01

    To evaluate the accuracy of the macular retinal layer segmentation software of the Spectralis spectral-domain (SD) optical coherence tomography (OCT) device (Heidelberg Engineering, Inc., Heidelberg, Germany) to discriminate between healthy and early glaucoma (EG) eyes. Prospective, cross-sectional study. Forty EG eyes and 40 healthy controls were included. All participants were examined using the standard posterior pole and the peripapillary retinal nerve fiber layer (pRNFL) protocols of the Spectralis OCT device. Using an Early Treatment Diagnostic Retinopathy Study circle at the macular level, the automated retinal segmentation software was applied to determine thicknesses of the following parameters: total retinal thickness, inner retinal layer (IRL), macular retinal nerve fiber layer (mRNFL), macular ganglion cell layer (mGCL), macular inner plexiform layer (mIPL), macular inner nuclear layer (mINL), macular outer plexiform layer (mOPL), macular outer nuclear layer (mONL), photoreceptors (PR), and retinal pigmentary epithelium (RPE). The ganglion cell complex (GCC) was determined by adding the mRNFL, mGCL, and mIPL parameters and the ganglion cell layer-inner plexiform layer (mGCL-IPL) was determined by combining the mGCL and mIPL parameters. Thickness of each layer was compared between the groups, and the layer and sector with the best area under the receiver operating characteristic curve (AUC) were identified. Comparison of pRNFL, IRL, mRNFL, mGCL, mIPL, mGCC, mGCL-IPL, mINL, mOPL, mONL, PR, and RPE parameters and total retinal thicknesses between groups for the different areas and their corresponding AUCs. Peripapillary RNFL was significantly thinner in the EG group globally and in all 6 sectors assessed (P < 0.0005). For the macular variables, retinal thickness was significantly reduced in the EG group for total retinal thickness, mIRL, mRNFL, mGCL, and mIPL. The 2 best isolated parameters to discriminate between the 2 groups were pRNFL (AUC, 0.956) and

  15. Measuring plate thickness using spatial local wavenumber filtering

    International Nuclear Information System (INIS)

    Kang, To; Han, Soon Woo; Park, Jin Ho; Lee, Jeong Han; Park, Gyu Hae; Jeon, Jun Young

    2016-01-01

    Corrosion on the surface of a structure can generate cracks or cause walls to thin. This can lead to fracturing, which can eventually lead to fatalities and property loss. In an effort to prevent this, laser imaging technology has been used over the last ten years to detect thin-plate structure, or relatively thin piping. The most common laser imaging was used to develop a new technology for inspecting and imaging a desired area in order to scan various structures for thin-plate structure and thin piping. However, this method builds images by measuring waves reflected from defects, and subsequently has a considerable time delay of a few milliseconds at each scanning point. In addition, the complexity of the system is high, due to additional required components, such as laser-focusing parts. This paper proposes a laser imaging method with an increased scanning speed, based on excitation and the measurement of standing waves in structures. The wavenumber of standing waves changes at sections with a geometrical discontinuity, such as thickness. Therefore, it is possible to detect defects in a structure by generating standing waves with a single frequency and scanning the waves at each point by with the laser scanning system. The proposed technique is demonstrated on a wall-thinned plate with a linear thickness variation

  16. Measurement of biofilm thickness. An effective Legionella risk assessment tool

    Energy Technology Data Exchange (ETDEWEB)

    Foret, Christophe [BKG France, Arnage (France); Martemianov, Serguei [Poitiers Univ. (FR). Lab. of Thermal Study (LET); Moscow Univ. (Russian Federation). Frumkin Inst. of Physical Chemistry and Electrochemistry; Hater, Wolfgang [BK Giulini GmbH, Duesseldorf (Germany); Merlet, Nicole; Chaussec, Guenole; Tribollet, Bernard

    2010-02-15

    The best way to prevent the risk of bacterial growth in water systems is to monitor and control the microorganisms (biofilm) attached to pipe walls. Three years of laboratory research led two Centre National de Recherche Scientifique (French National Center for Scientific Research) teams (UMR 6008 and UPR 15) to develop a tool designed to determine the average biofilm thickness. The average biofilm thickness measurements carried out on pilot plants fed with natural water were sufficiently accurate and sensitive to monitor the formation and development of biofilm in a water system and to determine the efficiency of the applied treatments. The implementation of appropriate treatments (type and dose of the treatment product) leads to a significant reduction in or even complete removal of the porous layer on the material surface. A reduction of the attached biomass, measured by the sensor, is connected to a decrease in the density of the bacterial attached to the material (viable flora in the plate count agar environment). (orig.)

  17. Online terahertz thickness measurement in films and coatings

    Science.gov (United States)

    Duling, Irl N.; White, Jeffrey S.

    2017-02-01

    Pulsed terahertz systems are currently being deployed for online process control and quality control of multi-layered products for use in the building products and aerospace industries. While many laboratory applications of terahertz can allow waveforms to be acquired at rates of 1 - 40 Hz, online applications require measurement rates of in excess of 100Hz. The existing technologies of thickness measurement (nuclear, x-ray, or laser gauges) have rates between 100 and 1000 Hz. At these rates, the single waveform bandwidth must still remain at 2THz or above to allow thinner layers to be measured. In the applications where terahertz can provide unique capability (e.g. multi-layer thickness, delamination, density) long-term stability must be guaranteed within the tolerance required by the measurement. This can mean multi-day stability of less than a micron. The software that runs on these systems must be flexible enough to allow multiple product configurations, while maintaining the simplicity required by plant operators. The final requirement is to have systems that can withstand the environmental conditions of the measurement. This might mean qualification in explosive environments, or operation in hot, wet or dusty environments. All of these requirements can put restrictions on not only the voltage of electronic circuitry used, but also the wavelength and optical power used for the transmitter and receiver. The application of terahertz systems to online process control presents unique challenges that not only effect the physical design of the system, but can also effect the choices made on the terahertz technology itself.

  18. Retinal sensitivity and choroidal thickness in high myopia.

    Science.gov (United States)

    Zaben, Ahmad; Zapata, Miguel Á; Garcia-Arumi, Jose

    2015-03-01

    To estimate the association between choroidal thickness in the macular area and retinal sensitivity in eyes with high myopia. This investigation was a transversal study of patients with high myopia, all of whom had their retinal sensitivity measured with macular integrity assessment microperimetry. The choroidal thicknesses in the macular area were then measured by optical coherence tomography, and statistical correlations between their functionality and the anatomical structuralism, as assessed by both types of measurements, were analyzed. Ninety-six eyes from 77 patients with high myopia were studied. The patients had a mean age ± standard deviation of 38.9 ± 13.2 years, with spherical equivalent values ranging from -6.00 diopter to -20.00 diopter (8.74 ± 2.73 diopter). The mean central choroidal thickness was 159.00 ± 50.57. The mean choroidal thickness was directly correlated with sensitivity (r = 0.306; P = 0.004) and visual acuity but indirectly correlated with the spherical equivalent values and patient age. The mean sensitivity was not significantly correlated with the macular foveal thickness (r = -0.174; P = 0.101) or with the overall macular thickness (r = 0.103; P = 0.334); furthermore, the mean sensitivity was significantly correlated with visual acuity (r = 0.431; P < 0.001) and the spherical equivalent values (r = -0.306; P = 0.003). Retinal sensitivity in highly myopic eyes is directly correlated with choroidal thickness and does not seem to be associated with retinal thickness. Thus, in patients with high myopia, accurate measurements of choroidal thickness may provide more accurate information about this pathologic condition because choroidal thickness correlates to a greater degree with the functional parameters, patient age, and spherical equivalent values.

  19. Association of statin use and hypertriglyceridemia with diabetic macular edema in patients with type 2 diabetes and diabetic retinopathy.

    Science.gov (United States)

    Chung, Yoo-Ri; Park, Sung Wook; Choi, Shin-Young; Kim, Seung Woo; Moon, Ka Young; Kim, Jeong Hun; Lee, Kihwang

    2017-01-07

    To investigate the effects of dyslipidemia and statin therapy on progression of diabetic retinopathy and diabetic macular edema in patients with type 2 diabetes. The medical records of 110 patients with type 2 diabetes (70 statin users and 40 non-users) were retrospectively reviewed. The two outcome measures were progression of diabetic retinopathy by two or more steps on the early treatment diabetic retinopathy study scale and diabetic macular edema based on optical coherence tomography. Serum lipid profiles were analyzed from 6 months prior to diagnosis of diabetic macular edema. Diabetic retinopathy progressed in 23% of statin users and 18% of non-users (p = 0.506), but diabetic macular edema was present in 23% of statin users and 48% of non-users (p = 0.008). Statins reduced low-density lipoprotein cholesterol levels in patients with and without diabetic macular edema (p = 0.043 and p = 0.031, respectively). Among statin users, patients with diabetic macular edema had higher levels of triglycerides (p = 0.004) and lower levels of high-density lipoprotein cholesterol (p = 0.033) than those without diabetic macular edema. Logistic regression analysis showed that statin use significantly lowered the risk of diabetic macular edema [odds ratio (OR): 0.33, 95% confidence interval (CI) 0.12-0.91, p = 0.032]. Hypertriglyceridemia at 6 months prior to development of macular edema was significantly associated with central retinal thickness (OR: 1.52; 95% CI 1.14-2.02, p = 0.005). Lipid lowering therapy with statins protected against the development of diabetic macular edema and progression of diabetic retinopathy in patients with type 2 diabetes. Hypertriglyceridemia could be used as a surrogate marker for diabetic macular edema.

  20. Correlation of Macular Focal Electroretinogram with Ellipsoid Zone Extension in Stargardt Disease

    Directory of Open Access Journals (Sweden)

    Edoardo Abed

    2017-01-01

    Full Text Available Stargardt disease (STGD1 is the most common cause of inherited juvenile macular degeneration. This disease is characterized by a progressive accumulation of lipofuscin in the outer retina and subsequent loss of photoreceptors and retinal pigment epithelium. The aim of this study was to evaluate the relationship between cone photoreceptor function and structure in STGD1. Macular function was assessed by visual acuity measurement and focal electroretinogram (FERG recording while spectral domain optical coherence tomography (SD-OCT imaging was performed to evaluate the integrity of photoreceptors. FERG amplitude was significantly reduced in patients with Stargardt disease (p<0.0001. The amplitude of FERG showed a negative relationship with interruption of ellipsoid zone (EZ (R2=0.54, p<0.0001 and a positive correlation with average macular thickness (AMT. Conversely, visual acuity was only weakly correlated with central macular thickness (CMT (R2=0.12, p=0.04. In conclusion, this study demonstrates that FERG amplitude is a reliable indicator of macular cone function while visual acuity reflects the activity of the foveal region. A precise assessment of macular cone function by FERG recording may be useful to monitor the progression of STGD1 and to select the optimal candidates to include in future clinical trials to treat this disease.

  1. Measurement of the through thickness compression of a battery separator

    Science.gov (United States)

    Yan, Shutian; Huang, Xiaosong; Xiao, Xinran

    2018-04-01

    The mechanical integrity of the separator is critical to the reliable operation of a battery. Due to its minimal thickness, compression experiments with a single/a few layers of separator are difficult to perform. In this work, a capacitance based displacement set-up has been developed for the measurement of the through thickness direction (TTD) compression stress-strain behavior of the separator and the investigation of its interaction with the electrode. The experiments were performed for a stack of two layers of Celgard 2400 separator, NMC cathode, and separator/NMC cathode/separator stack in both dry and wet (i.e. submersed in dimethyl carbonate DMC) conditions. The experimental results reveal that the separator compression modulus can be significantly affected by the presence of DMC. The iso-stress based rule of mixtures was used to compute the compressive stress-strain curve for the stack from that of the separator and NMC layer. The computed curve agreed with the experimental curve reasonably well up to about 0.16 strain but deviated significantly to a softer response at higher strains. The results suggest that, in the stack, the TTD compressive deformation of the separator is influenced by the NMC cathode.

  2. Single intravitreal bevacizumab injection effects on contrast sensitivity in macular edema from branch retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Rony Carlos Preti

    2012-02-01

    Full Text Available PURPOSE: To evaluate the effect of a single intravitreal bevacizumab injection on visual acuity, contrast sensitivity and optical coherence tomography-measured central macular thickness in eyes with macular edema from branch retinal vein occlusion. METHODS: Seventeen eyes of 17 patients with macular edema from unilateral branch retinal vein occlusion were treated with a single bevacizumab injection. Patients were submitted to a complete evaluation including best corrected visual acuity, contrast sensitivity and optical coherence tomography measurements before treatment and one and three months after injection. Visual acuity, contrast sensitivity and optical coherence tomography measurements were compared to baseline values. RESULTS: Mean visual acuity measurement improved from 0.77 logMAR at baseline to 0.613 logMAR one month after injection (P=0.0001 but worsened to 0.75 logMAR after three months. Contrast sensitivity test demonstrated significant improvement at spatial frequencies of 3, 6, 12 and 18 cycles/degree one month after injection and at the spatial frequency of 12 cycles/degree three months after treatment. Mean ± standard deviation baseline central macular thickness (552 ± 150 µm reduced significantly one month (322 ± 127 µm, P=0.0001 and three months (439 ± 179 µm, P=0.01 after treatment. CONCLUSIONS: Bevacizumab injection improves visual acuity and contrast sensitivity and reduces central macular thickness one month after treatment. Visual acuity returns to baseline levels at the 3-month follow-up, but some beneficial effect of the treatment is still present at that time, as evidenced by optical coherence tomography-measured central macular thickness and contrast sensitivity measurements.

  3. Measurement of wall thickness with electrodynamic test heads

    International Nuclear Information System (INIS)

    Koch, R.; Maurer, A.

    1993-01-01

    Starting from the boundary conditions fixed by the physical properties of the electromagnetic/acoustic conversion and the operating limits which result from these for the sensors used, the use of electro-dynamic ultrasonic transducers for measuring wall thickness and double checks in plants for automatic production inspection and production control is shown. The sensor itself is the heart of a test system, but only the equipment and plant concepts surrounding the sensor make economic solution of the test problem possible. The quality of the signals which are supplied by a sensor, determines the quality of a test system. This can only be achieved by optimising all parts of a complex automatic test rig, such as the test head, mechanics, electronics and evaluation for the test problem concerned. (orig./HP) [de

  4. Thick Films acoustic sensors devoted to MTR environment measurements. Thick Films acoustic sensors devoted to Material Testing Reactor environment measurements

    Energy Technology Data Exchange (ETDEWEB)

    Very, F.; Rosenkrantz, E.; Combette, P.; Ferrandis, J.Y. [University Montpellier, IES, UMR 5214, F-34000, Montpellier (France); CNRS, IES, UMR 5214, F-34000, Montpellier (France); Fourmentel, D.; Destouches, C.; Villard, J.F. [CEA, DEN, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St Paul lez Durance (France)

    2015-07-01

    The development of advanced instrumentation for in-pile experiments in Material Testing Reactor constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. An acoustic method for fission gas release detection was tested with success during a first experiment called REMORA 3 in 2010 and 2011, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). The maximal temperature on the sensor during the irradiation was about 150 deg. C. In this paper we present a thick film transducer produce by screen printing process. The screen printing of piezoelectric offers a wide range of possible applications for the development of acoustic sensors and piezoelectric structure for measurements in high temperature environment. We firstly produced a Lead Zirconate Titanate (PZT) based paste composed of Pz27 powder from Ferroperm, CF7575 glass, and organic solvent ESL 400. Likewise a Bismuth Titanate based paste synthesized in our laboratory was produced. With these inks we produced thick film up to 130 μm by screen printing process. Material properties characterizations of these thick-film resonators are essential for device design and applications. The piezoelectric coefficients d33 and pyro-electric P(T) coefficient are investigated. The highest P(T) and d33 are respectively 80 μC.m{sup -2}.K{sup -1} and 130 μC.N{sup -1} for the PZT transducer -which validates the fabrication process-. In view of the development of this transducer oriented for high temperature and irradiation environment, we investigated the electrical properties of the transducers for different ranges of frequencies and temperature - from 20 Hz up to 40 MHz between 30 and 400 deg. C. We highlight the evolution of the impedance response and piezoelectric parameters of screen printed piezoelectric structures on alumina. Shortly an irradiation will be realized in

  5. Thick Films acoustic sensors devoted to MTR environment measurements. Thick Films acoustic sensors devoted to Material Testing Reactor environment measurements

    International Nuclear Information System (INIS)

    Very, F.; Rosenkrantz, E.; Combette, P.; Ferrandis, J.Y.; Fourmentel, D.; Destouches, C.; Villard, J.F.

    2015-01-01

    The development of advanced instrumentation for in-pile experiments in Material Testing Reactor constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. An acoustic method for fission gas release detection was tested with success during a first experiment called REMORA 3 in 2010 and 2011, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). The maximal temperature on the sensor during the irradiation was about 150 deg. C. In this paper we present a thick film transducer produce by screen printing process. The screen printing of piezoelectric offers a wide range of possible applications for the development of acoustic sensors and piezoelectric structure for measurements in high temperature environment. We firstly produced a Lead Zirconate Titanate (PZT) based paste composed of Pz27 powder from Ferroperm, CF7575 glass, and organic solvent ESL 400. Likewise a Bismuth Titanate based paste synthesized in our laboratory was produced. With these inks we produced thick film up to 130 μm by screen printing process. Material properties characterizations of these thick-film resonators are essential for device design and applications. The piezoelectric coefficients d33 and pyro-electric P(T) coefficient are investigated. The highest P(T) and d33 are respectively 80 μC.m -2 .K -1 and 130 μC.N -1 for the PZT transducer -which validates the fabrication process-. In view of the development of this transducer oriented for high temperature and irradiation environment, we investigated the electrical properties of the transducers for different ranges of frequencies and temperature - from 20 Hz up to 40 MHz between 30 and 400 deg. C. We highlight the evolution of the impedance response and piezoelectric parameters of screen printed piezoelectric structures on alumina. Shortly an irradiation will be realized in order to

  6. A Study on the Thickness Measurement of Thin Film by Ultrasonic Wave

    International Nuclear Information System (INIS)

    Han, Eung Kyo; Lee, Jae Joon; Kim, Jae Yeol

    1988-01-01

    Recently, it is gradually raised necessity that thickness of thin film is measured accurately and managed in industrial circles and medical world. In this study, regarding to the thickness of film which is in opaque object and is beyond distance resolution capacity, thickness measurement was done by MEM-cepstrum analysis of received ultrasonic wave. In measurement results, film thickness which is beyond distance resolution capacity was measured accurately. And within thickness range that don't exist interference, thickness measurement by MEM-ceptrum analysis was impossible

  7. Macular hole: 10 and 20-MHz ultrasound and spectral-domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Juliana Mantovani Bottós

    2012-12-01

    Full Text Available PURPOSE: Optical coherence tomography (OCT is valuable for macula evaluation. However, as this technique relies on light energy it cannot be performed in the presence of opaque media. In such cases, the ultrasound (US may predict some macular features. The aim of this study was to characterize images obtained by ultrasound with 10 and 20-MHz transducers comparing to OCT, as well as to analyze the relationship between the vitreous and retina in eyes with macular hole (MH. METHODS: 29 eyes of 22 patients with biomicroscopic evidence of MH at different stages were included. All patients were evaluated using ultrasonography with 10 and 20-MHz transducers and OCT. RESULTS: OCT identified signs of MH in 25 of 29 eyes. The remaining 4 cases not identified by US were pseudoholes caused by epiretinal membranes. In MH stages I (2 eyes and II (1 eye, both transducers were not useful to analyze the macular thickening, but suggestive findings as macular irregularity, operculum or partial posterior vitreous detachment (PVD were highlighted. In stages III (14 eyes and IV (5 eyes, both transducers identified the double hump irregularity and thickening. US could measure the macular thickness and other suggestive findings for MH: operculum, vitreomacular traction and partial or complete PVD. In cases of pseudoholes, US identified irregularities macular contour and a discrete depression. CONCLUSION: 10-MHz US was useful for an overall assessment of the vitreous body as well as its relationship to the retina. The 20-MHz transducer allowed valuable information on the vitreomacular interface and macular contour. OCT provides superior quality for fine morphological study of macular area, except in cases of opaque media. In these cases, and even if OCT is not available, the combined US study is able to provide a valid evaluation of the macular area improving therapeutic approach.

  8. Nondestructive testing technology for measurement coatings thickness on material

    International Nuclear Information System (INIS)

    Yang Mingtai; Wu Lunqiang; Zhang Lianping

    2008-01-01

    The principle, applicability range, advantage and disadvantage of electromagnetic, eddy current method, β backscatter method and XRF methods for nondestructive testing coating thickness of material have been reviewed. The relevant apparatus and manufacturers have been summarized. And the application and developmental direction of manufacturers for nondestructive testing coatings thickness has been foreshowed. (authors)

  9. Macular edema in underserved diabetic patients: Improving detection by enhancing the optical signature and data analysis techniques

    Science.gov (United States)

    Alhamami, Mastour Abdullah

    Diabetic retinopathy and diabetic macular edema are chief causes of vision loss in working adults. Thus, retinal screening of patients with diabetes has become standard practice in some countries to prevent visual impairment and blindness from diabetic retinopathy. One goal is to improve techniques currently used to diagnose diabetic retinopathy. Another goal is to probe pathophysiological changes seen with imaging methods. Analysis was performed on a novel dataset from more than 2000 underserved adult diabetic patients, who were recruited for a screening study for diabetic eye disease. Data were collected from four county clinics at Alameda Health, Alameda County, CA. Over 90% of patients self-identified as a racial/ethnic identity other than non-Hispanic white. We investigated the prevalence and optical properties of macular edema. In the first study, a retrospective cohort study was performed to compare macular thickness in diabetic patients with and without macular edema to determine the presence of damage to the external limiting membrane or and the relation of damage to the ELM to damage to photoreceptors. In the second study, we investigated whether the information in red light better visualizes cysts in diabetic macular edema, as compared to green light. In the third study, we investigated whether the demographic and blood glucose information predict diabetic macular edema. Three logistic regression analyses were compared. In the fourth study, we examined how different outcome measures of retinal thickness vary with demographic and blood glucose measures, using a trichotomous variable for retinal thickness. The findings point strongly to large individual differences in the development of macular edema, which is difficult to diagnose with the most common methods in dark eyes. Further, while blood glucose was found to be important, there are additional differences in the potential for macular edema that are associated with ethnic group and gender.

  10. Rotary union for use with ultrasonic thickness measuring probe

    Science.gov (United States)

    Nachbar, Henry D.

    1992-01-01

    A rotary union for rotatably supporting an ultrasonic probe operable to nondestructively measure the thickness of steam generator tubes to determine the amount of corrosion experienced by the tubes includes a stationary body having a bore therethrough and an outlet drain, and a fitting rotatably mounted within the upper end of the body. The fitting has a bore aligned with the bore of the body. An electrical cable positioned within a water supply tube in an annular arrangement passes through the bore of the body and the bore of the fitting. This annular arrangement, in turn, is positioned within a connector element which extends outwardly from the fitting bore and is connected to the ultrasonic probe. An elastomeric lower bushing seals the annular arrangement to the lower end of the rotary union body and an elastomeric upper bushing seals the connector element to the fitting to permit the connector element and the ultrasonic probe connected thereto to rotate with the fitting relative to the body. The lower and upper bushings permit water to be passed through the annular arrangement and into the ultrasonic probe and thereafter discharged between the annular arrangement and the connector element to the outlet drain of the rotary union body.

  11. Rotary union for use with ultrasonic thickness measuring probe

    International Nuclear Information System (INIS)

    Nachbar, H.D.

    1992-01-01

    A rotary union for rotatably supporting an ultrasonic probe operable to nondestructively measure the thickness of steam generator tubes to determine the amount of corrosion experienced by the tubes includes a stationary body having a bore therethrough and an outlet drain, and a fitting rotatably mounted within the upper end of the body. The fitting has a bore aligned with the bore of the body. An electrical cable positioned within a water supply tube in an annular arrangement passes through the bore of the body and the bore of the fitting. This annular arrangement, in turn, is positioned within a connector element which extends outwardly from the fitting bore and is connected to the ultrasonic probe. An elastomeric lower bushing seals the annular arrangement to the lower end of the rotary union body and an elastomeric upper bushing seals the connector element to the fitting to permit the connector element and the ultrasonic probe connected thereto to rotate with the fitting relative to the body. The lower and upper bushings permit water to be passed through the annular arrangement and into the ultrasonic probe and thereafter discharged between the annular arrangement and the connector element to the outlet drain of the rotary union body. 5 figs

  12. Thickness gauge for the measurement of the density of graphite

    International Nuclear Information System (INIS)

    Leveque, P.; Gasnier, M.; Hours, R.; Jouquet, G.; Rappeneau, J.; Tanguy, J.C.

    1961-01-01

    A thickness gauge was built, based on absorption of Bremsstrahlung generated in a Be target by a ( 90 Sr + 90 Y) β- source. This allows rapid and precise estimation (95 per cent probable error = 0.7 per cent) of the densities in slabs of graphite having a constant thickness of 25 ± 0.05 mm, the diameter of the beam being about 1 cm. Results obtained in this way are presented. (author) [fr

  13. Biochemical Measurements of Free Opsin in Macular Degeneration Eyes: Examining the 11-CIS Retinal Deficiency Hypothesis of Delayed Dark Adaptation (An American Ophthalmological Society Thesis).

    Science.gov (United States)

    Hanneken, Anne; Neikirk, Thomas; Johnson, Jennifer; Kono, Masahiro

    2017-08-01

    To test the hypothesis that delayed dark adaptation in patients with macular degeneration is due to an excess of free unliganded opsin (apo-opsin) and a deficiency of the visual chromophore, 11 -cis retinal, in rod outer segments. A total of 50 human autopsy eyes were harvested from donors with and without macular degeneration within 2-24 hrs. postmortem. Protocols were developed which permitted dark adaptation of normal human eyes after death and enucleation. Biochemical methods of purifying rod outer segments were optimized and the concentration of rhodopsin and apo-opsin was measured with UV-visible scanning spectroscopy. The presence of apo-opsin was calculated by measuring the difference in the rhodopsin absorption spectra before and after the addition of 11 -cis retinal. A total of 20 normal eyes and 16 eyes from donors with early, intermediate and advanced stages of macular degeneration were included in the final analysis. Dark adaptation was achieved by harvesting whole globes in low light, transferring into dark (light-proof) canisters and dissecting the globes using infrared light and image converters for visualization. Apo-opsin was readily detected in positive controls after the addition of 11 -cis retinal. Normal autopsy eyes showed no evidence of apo-opsin. Eyes with macular degeneration also showed no evidence of apo-opsin, regardless of the severity of disease. Methods have been developed to study dark adaptation in human autopsy eyes. Eyes with age-related macular degeneration do not show a deficiency of 11 -cis retinal or an excess of apo-opsin within rod outer segments.

  14. Mass thickness measurement of dual-sample by dual-energy X-rays

    International Nuclear Information System (INIS)

    Chen Mincong; Li Hongmei; Chen Ziyu; Shen Ji

    2008-01-01

    X-ray equivalent energy can be used to measure mass thicknesses of materials. Based on this, a method of mass thickness measurement of dual-sample was discussed. It was found that in the range of sample mass thickness under investigation, the equivalent mass attenuation coefficient of a component could be used to compute mass thicknesses of a dual-sample, with relative errors of less than 5%. Mass thickness measurement of a fish sample was performed, and the fish bone and flesh could be displayed separately and clearly by their own mass thicknesses. This indicates that the method is effective in mass thickness measurement of dual-sample of suitable thicknesses. (authors)

  15. Development of examination technique for oxide layer thickness measurement of irradiated fuel rods

    International Nuclear Information System (INIS)

    Koo, D. S.; Park, S. W.; Kim, J. H.; Seo, H. S.; Min, D. K.; Kim, E. K.; Chun, Y. B.; Bang, K. S.

    1999-06-01

    Technique for oxide layer thickness measurement of irradiated fuel rods was developed to measure oxide layer thickness and study characteristic of fuel rods. Oxide layer thickness of irradiated fuels were measured, analyzed. Outer oxide layer thickness of 3 cycle-irradiated fuel rods were 20 - 30 μm, inner oxide layer thickness 0 - 10 μm and inner oxide layer thickness on cracked cladding about 30 μm. Oxide layer thickness of 4 cycle-irradiated fuel rods were about 2 times as thick as those of 1 cycle-irradiated fuel rods. Oxide layer on lower region of irradiated fuel rods was thin and oxide layer from lower region to upper region indicated gradual increase in thickness. Oxide layer thickness from 2500 to 3000 mm showed maximum and oxide layer thickness from 3000 to top region of irradiated fuel rods showed decreasing trend. Inner oxide layer thicknesses of 4 cycle-irradiated fuel rod were about 8 μm at 750 - 3500 mm from the bottom end of fuel rod. Outer oxide layer thickness were about 8 μm at 750 - 1000 mm from the bottom end of fuel rod. These indicated gradual increase up to upper region from the bottom end of fuel rod. These indicated gradual increase up to upper region from the bottom end of fuel. Oxide layer thickness technique will apply safety evaluation and study of reactor fuels. (author). 6 refs., 14 figs

  16. Precursors of Age-Related Macular Degeneration

    DEFF Research Database (Denmark)

    Munch, Inger Christine; Linneberg, Allan; Larsen, Michael

    2013-01-01

    PURPOSE: To investigate associations of small, hard macular drusen and larger macular drusen with obesity-related risk factors. METHODS: Cross-sectional study of 888 subjects aged 30-60 years characterized using anthropometric measurements and blood sample analyses. Physical activity was assessed...... by questionnaire. Digital grayscale fundus photographs were recorded in red-free illumination and graded for the presence of macular drusen >63µm in either eye and the presence of 20 or more small, hard macular drusen as a mean of both eyes. RESULTS: Macular drusen >63µm were associated with the level of physical...... activity, the age- and sex adjusted odds ratio being 0.33 (95% confidence interval 0.13-0.82, P=0.016) for participants who were physically active more than 7 h/week compared with participants active 0-2 h/week. In women, macular drusen >63µm were associated with higher serum triglycerides (P=0...

  17. Radioisotope albedo method for measuring thickness of polymers coatings on metal basis

    International Nuclear Information System (INIS)

    Kapranov, B.I.; Myakin'kova, L.V.; Shaverin, V.A.

    1986-01-01

    Theoretical analysis of albedo thickness measuring of polymer coating-metal composite has been made and experimental studies of the range of tested thicknesses of polymer coating when different metal bases and radiation sources are used have been conducted. It is shown that the thickness of polymer coating on metal can be measured using backscattered γ-radiation in the energy range of 20-120 keV at the error 0.15-0.8 mm, at that, for thickness up to 23 mm the use of 147 Pm isotope can be defined as the optimum one; for thicknesses up to 40 mm 241 Am should be used; at thicknesses up to 60 mm - 57 Co. The AGAT-1 albedo gamma thickness gage, designed for measuring thickness of fiber glass coating up to 20 mm on metal base, is described

  18. What Is Macular Edema?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Macular Edema Symptoms Macular Edema Diagnosis Macular Edema Treatment What Is Macular Edema? Leer en Español: ¿Qué ...

  19. What Is Macular Edema?

    Medline Plus

    Full Text Available ... Macular Edema Treatment What Is Macular Edema? Leer en Español: ¿Qué es un edema macular? Dec. 01, 2010 Macular edema is swelling or thickening of the eye's macula, the part of your eye responsible for detailed, central vision. The macula is a very small area ...

  20. Reliability of a two-wavelength autofluorescence technique by Heidelberg Spectralis to measure macular pigment optical density in Asian subjects.

    Science.gov (United States)

    Obana, Akira; Gellermann, Werner; Gohto, Yuko; Seto, Takahiko; Sasano, Hiroyuki; Tanito, Masaki; Okazaki, Shigetoshi

    2018-03-01

    This study evaluates the accuracy of an objective two-wavelength fundus autofluorescence technique for the purpose of measuring the macular pigment optical density (MPOD) in Asian pigmented eyes. Potential differences between MPOD values obtained via autofluorescence technique and subjective heterochromatic photometry (HFP) were examined. Inter-examiner reproducibility between three examiners and test-retest reliability over five time points were also explored. Subjects were 27 healthy Japanese volunteers aged 24 to 58 (mean ± standard deviation, 40.2 ± 9.0) years. An MPOD module of the Spectralis MultiColor instrument configuration (Spectralis-MP) was used for the autofluorescence technique, and a Macular Metrics Densitometer (MM) was used for HFP. The mean MPOD values at 0.25° and 0.5° eccentricities using the Spectralis-MP were 0.51 ± 0.12 and 0.48 ± 0.13, respectively. In comparison, the MM based values were 0.72 ± 0.23 and 0.61 ± 0.25, respectively. High correlations between the Spectralis-MP and MM instrument were found (Pearson's correlation coefficients of 0.73 and 0.87 at 0.25° and 0.5° eccentricities, respectively), but there was a systematic bias: the MPOD values by MM method were significantly higher than those by Spectralis-MP at 0.25° eccentricity. High inter-examiner reproducibility and test-retest reliability were found for MM measurements at 0.5° eccentricity, but not at 0.25°. The Spectralis-MP showed less inter-examiner and test-retest variability than the MM instrument at 0.25° and 0.5° eccentricities. We conclude that the Spectralis-MP, given its high agreement with the HFP method and due to its higher reproducibility and reliability, is well suited for clinical measurements of MPOD levels in Asian pigmented eyes. Copyright © 2018. Published by Elsevier Ltd.

  1. Interventions for the treatment of uveitic macular edema: a systematic review and meta-analysis

    Science.gov (United States)

    Karim, Rushmia; Sykakis, Evripidis; Lightman, Susan; Fraser-Bell, Samantha

    2013-01-01

    Background Uveitic macular edema is the major cause of reduced vision in eyes with uveitis. Objectives To assess the effectiveness of interventions in the treatment of uveitic macular edema. Search strategy Cochrane Central Register of Controlled Trials, Medline, and Embase. There were no language or data restrictions in the search for trials. The databases were last searched on December 1, 2011. Reference lists of included trials were searched. Archives of Ophthalmology, Ophthalmology, Retina, the British Journal of Ophthalmology, and the New England Journal of Medicine were searched for clinical trials and reviews. Selection criteria Participants of any age and sex with any type of uveitic macular edema were included. Early, chronic, refractory, or secondary uveitic macular edema were included. We included trials that compared any interventions of any dose and duration, including comparison with another treatment, sham treatment, or no treatment. Data collection and analysis Best-corrected visual acuity and central macular thickness were the primary outcome measures. Secondary outcome data including adverse effects were collected. Conclusion More results from randomized controlled trials with long follow-up periods are needed for interventions for uveitic macular edema to assist in determining the overall long-term benefit of different treatments. The only intervention with sufficiently robust randomized controlled trials for a meta-analysis was acetazolamide, which was shown to be ineffective in improving vision in eyes with uveitic macular edema, and is clinically now rarely used. Interventions showing promise in this disease include dexamethasone implants, immunomodulatory drugs and anti-vascular endothelial growth-factor agents. When macular edema has become refractory after multiple interventions, pars plana vitrectomy could be considered. The disease pathophysiology is uncertain and the course of disease unpredictable. As there are no clear guidelines from

  2. Correlations Between Macular, Skin, and Serum Carotenoids

    Science.gov (United States)

    Conrady, Christopher D.; Bell, James P.; Besch, Brian M.; Gorusupudi, Aruna; Farnsworth, Kelliann; Ermakov, Igor; Sharifzadeh, Mohsen; Ermakova, Maia; Gellermann, Werner; Bernstein, Paul S.

    2017-01-01

    Purpose Ocular and systemic measurement and imaging of the macular carotenoids lutein and zeaxanthin have been employed extensively as potential biomarkers of AMD risk. In this study, we systematically compare dual wavelength retinal autofluorescence imaging (AFI) of macular pigment with skin resonance Raman spectroscopy (RRS) and serum carotenoid levels in a clinic-based population. Methods Eighty-eight patients were recruited from retina and general ophthalmology practices from a tertiary referral center and excluded only if they did not have all three modalities tested, had a diagnosis of macular telangiectasia (MacTel) or Stargardt disease, or had poor AFI image quality. Skin, macular, and serum carotenoid levels were measured by RRS, AFI, and HPLC, respectively. Results Skin RRS measurements and serum zeaxanthin concentrations correlated most strongly with AFI macular pigment volume under the curve (MPVUC) measurements up to 9° eccentricity relative to MPVUC or rotationally averaged macular pigment optical density (MPOD) measurements at smaller eccentricities. These measurements were reproducible and not significantly affected by cataracts. We also found that these techniques could readily identify subjects taking oral carotenoid-containing supplements. Conclusions Larger macular pigment volume AFI and skin RRS measurements are noninvasive, objective, and reliable methods to assess ocular and systemic carotenoid levels. They are an attractive alternative to psychophysical and optical methods that measure MPOD at a limited number of eccentricities. Consequently, skin RRS and MPVUC at 9° are both reasonable biomarkers of macular carotenoid status that could be readily adapted to research and clinical settings. PMID:28728169

  3. Practicable methods for histological section thickness measurement in quantitative stereological analyses.

    Science.gov (United States)

    Matenaers, Cyrill; Popper, Bastian; Rieger, Alexandra; Wanke, Rüdiger; Blutke, Andreas

    2018-01-01

    The accuracy of quantitative stereological analysis tools such as the (physical) disector method substantially depends on the precise determination of the thickness of the analyzed histological sections. One conventional method for measurement of histological section thickness is to re-embed the section of interest vertically to its original section plane. The section thickness is then measured in a subsequently prepared histological section of this orthogonally re-embedded sample. However, the orthogonal re-embedding (ORE) technique is quite work- and time-intensive and may produce inaccurate section thickness measurement values due to unintentional slightly oblique (non-orthogonal) positioning of the re-embedded sample-section. Here, an improved ORE method is presented, allowing for determination of the factual section plane angle of the re-embedded section, and correction of measured section thickness values for oblique (non-orthogonal) sectioning. For this, the analyzed section is mounted flat on a foil of known thickness (calibration foil) and both the section and the calibration foil are then vertically (re-)embedded. The section angle of the re-embedded section is then calculated from the deviation of the measured section thickness of the calibration foil and its factual thickness, using basic geometry. To find a practicable, fast, and accurate alternative to ORE, the suitability of spectral reflectance (SR) measurement for determination of plastic section thicknesses was evaluated. Using a commercially available optical reflectometer (F20, Filmetrics®, USA), the thicknesses of 0.5 μm thick semi-thin Epon (glycid ether)-sections and of 1-3 μm thick plastic sections (glycolmethacrylate/ methylmethacrylate, GMA/MMA), as regularly used in physical disector analyses, could precisely be measured within few seconds. Compared to the measured section thicknesses determined by ORE, SR measures displayed less than 1% deviation. Our results prove the applicability

  4. Macular Diplopia.

    Science.gov (United States)

    Shippman, Sara; Cohen, Kenneth R; Heiser, Larissa

    2015-01-01

    Maculopathies affect point-to-point foveal correspondence causing diplopia. The effect that the maculopathies have on the interaction of central sensory fusion and peripheral fusion are different than the usual understanding of treatment for diplopia. This paper reviews the pathophysiology of macular diplopia, describes the binocular pathology causing the diplopia, discusses the clinical evaluation, and reviews the present treatments including some newer treatment techniques. © 2015 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 65, 2015, ISSN 0065-955X, E-ISSN 1553-4448.

  5. Comparison of Macular Integrity Assessment (MAIA ™, MP-3, and the Humphrey Field Analyzer in the Evaluation of the Relationship between the Structure and Function of the Macula.

    Directory of Open Access Journals (Sweden)

    Kazuyuki Hirooka

    Full Text Available This study was conducted in order to compare relationships between the macular visual field (VF mean sensitivity measured by MAIATM (Macular Integrity Assessment, MP-3, or Humphry field analyzer (HFA and the ganglion cell and inner plexiform layer (GCA thicknesses.This cross-sectional study examined 73 glaucoma patients and 19 normal subjects. All subjects underwent measurements for GCA thickness by Cirrus HD-OCT and static threshold perimetry using MAIATM, MP-3, or HFA. VF and OCT in the retinal view were used to examine both the global relationship between the VF sensitivity and GCA thickness, and the superior hemiretina and inferior hemiretina. The relationship between the GCA thickness and macular sensitivity was examined by Spearman correlation analysis.For each instrument, statistically significant macular VF sensitivity (dB and GCA thickness relationships were observed using the decibel scale (R = 0.547-0.687, all P < 0.001. The highest correlation for the global (R = 0.682 and the superior hemiretina (R = 0.594 GCA thickness-VF mean sensitivity was observed by the HFA. The highest correlation for the inferior hemiretina (R = 0.687 GCA thickness-VF mean sensitivity was observed by the MP-3. Among the three VF measurement instruments, however, no significant differences were found for the structure-function relationships.All three VF measurement instruments found similar structure-function relationships in the central VF.

  6. Central Corneal Thickness Measurement by Ultrasound versus Orbscan II

    Directory of Open Access Journals (Sweden)

    Amir Faramarzi

    2008-12-01

    Full Text Available

    PURPOSE: To compare Orbscan II and ultrasonic pachymetry for measurement of central corneal thickness (CCT in eyes scheduled for keratorefractive surgery. METHODS: CCT was measured using Orbscan II (Bausch & Lomb, USA and then by ultrasonic pachymetry (Tomey SP-3000, Tomey Ltd, Japan in 100 eyes of 100 patients with no history of ocular surgery scheduled for excimer laser refractive surgery. RESULTS: Mean CCT was 544.7±35.5 (range 453-637 µm by ultrasonic pachymetry versus 546.9±41.6 (range 435-648 µm measured by Orbscan II applying an acoustic factor of 0.92 (P=0.14. The standard deviation of measurements was greater with Orbscan pachymetry but the difference was not statistically significant. CONCLUSION: CCT measurements by Orbscan II (applying an acoustic factor and by ultrasonic pachymetry are not significantly different; however, when CCT readings by Orbscan II are in the lower range, it is advisable to recheck the measurements using ultrasonic pachymetry.

  1. Relationship between the thickness of the renal cortex and age: study with CT measurement

    International Nuclear Information System (INIS)

    Xu Yufeng; Tang Guangjian

    2004-01-01

    Objective: To study the relationship between the renal cortical thickness and age, and to establish the range of the normal renal cortex thickness by using CT measurement in different age groups so as to obtain a best age-related and practicable method for clinical measurement. Methods: (1) the accuracy of measuring renal cortical thickness by CT was evaluated: 18 kidney resected due to renal neoplasm were studied and the cortical thickness of the normal part of these specimens was assessed. The difference between the renal cortical thickness of specimens and preoperative measurements of renal cortex of the same patient by contrast enhanced CT was analyzed statistically. (2) 120 patients without history of renal disease or long term usage of potentially renal toxic drugs or history of hypertension were examined by CT with indication (s) other than renal disease. All the patients were divided into 20-40, 41-60, and 61-80 year-old groups. The renal cortical and parenchymal thickness and renal size were measured in three CT sections. The difference of the measurements among the three groups and their relationship to age was analyzed statistically. Results: There was no significant difference between the renal cortical thickness measured by enhanced spiral CT and measured in renal specimens (t=0.80, P=0.43). The renal cortical thickness in three groups was 0.73 cm, 0.65 cm, and 0.53 cm, respectively, and the differences among the three groups were significant (F=93.430, P 0.05). Conclusion: The measurement of the renal cortical thickness with enhanced spiral CT was reliable and was a sensitive method in investigating the morphologic changes of the kidney. The renal cortical thickness of normal kidney diminishes with age, but the change of the ratio of thickness of renal cortex to renal parenchyma with age was not significant

  2. Clinical analysis of intravitreal injection of triamcinolone acetonide combined macular grid photocoagulation treatment for macular edema

    Directory of Open Access Journals (Sweden)

    Xian-Hua Jing

    2014-10-01

    Full Text Available AIM: To investigate the clinical efficacy and safety of intravitreal injection of triamcinolone combined macular grid photocoagulation treatment for macular edema. METHODS: Totally 150 cases(150 eyeswith macular edema in our hospital from July 2009 to November 2013 were selected, which were randomly divided into study group(75 cases, 75 eyesand control group(75 cases, 75 eyes. The cases in control group were treated with macular grid photocoagulation treatment, those in the study group used triamcinolone acetonide combined macular grid photocoagulation treatment. Best corrected visual acuity(BCVA, parallel optical coherence tomography(OCTand fundus fluorescein angiography(FFAwere detected before treatment, after treatment 7d, 1, 3, and 9mo. RESULTS:After the treatment, patients' vision were significantly improved in two groups(PPPP>0.05. Fovea macular neurosensory retinal thickness in the study group was significantly lower than that in control group(PCONCLUSION: Triamcinolone acetonide combined macular grid photocoagulation treatment is accurate, can effectively improve the visual acuity, reduce macular edema, it is safe and reliable, and suitable for clinical application.

  3. Quantitative computed tomography measures of emphysema and airway wall thickness are related to respiratory symptoms

    DEFF Research Database (Denmark)

    Grydeland, Thomas B; Dirksen, Asger; Coxson, Harvey O

    2010-01-01

    There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness.......There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness....

  4. Familial trends in a population with macular holes.

    Science.gov (United States)

    Kay, Christine Nichols; Pavan, Peter Reed; Small, Laurie Buccina; Zhang, Tao; Zamba, Gideon K D; Cohen, Steven Myles

    2012-04-01

    To determine if patients with macular hole report an increased family history of macular hole compared with control patients and compare the report of family history between patients with unilateral and bilateral macular holes. This was a multicenter case-control study. Charts of patients coded with diagnosis of macular hole were reviewed, and the diagnosis of idiopathic full-thickness macular hole was ascertained in 166 patients. The control group comprised 136 patients without macular hole or trauma who presented with senile cataract. Family history was obtained from all patients through a telephone interview. Six of 166 (3.6%) macular hole patients surveyed reported a history of macular hole in a primary relative compared with none of 136 (0.0%) control patients (odds ratio is infinity, with 95% confidence interval 1.295 to infinity); however, this finding may be explained by confounders such as age and number of family members. Two of the 142 (1.4%) patients with unilateral holes versus 4 of the 24 (16.7%) patients with bilateral holes reported a family history (odds ratio is 0.0714, with 95% confidence interval 0.0063 to 0.5537), and this finding remains significant when logistic regression is performed to evaluate variables of age and number of family members as potential confounders. There is an increased report of familial occurrence of macular hole in patients with macular holes compared with control patients; however, logistic regression relates this finding to variables of age and number of family members. Patients with bilateral macular holes are more likely to report a family history of macular hole than patients with unilateral macular holes, and this finding remains significant in the presence of age and number of family members. These findings may suggest a familial component to macular hole.

  5. Investigation of the Section Thickness Measurement in Tomosynthesis by Thin Metal Plate Edge Method.

    Science.gov (United States)

    Ikeno, Kaoru; Akita, Tsunemichi; Hanai, Kozo; Muramatsu, Yoshihisa

    When performing tomosynthesis, the section thickness needs to be set depending on a radiographic part and its diagnostic purpose. However, the section thickness in tomosynthesis has not been clearly defined and its measurement method has not been established yet. In this study, we devised the alternative measurement method to diagnose the section thickness using an edge of thin metal plate, and compared with the simulation results, the wire and bead method reported in the previous papers. The tomographic image of the thin metal plate positioned on the table top inclining 30 degrees, which showed the edge spread function (ESF) of each tomographic height, was taken, and then the line spread function (LSF) was obtained by differentiating the ESF image. For the next, a profile curve was plotted by maximum values of LSF of each tomographic height, and a section thickness was calculated using the full width at half maximum (FWHM) of the profile curve. The edge method derived the section thickness close to the simulation results than the other methods. Further, the section thickness depends on the thickness of the metal plate and not the material. The thickness of the metal plate suitable for the evaluation of section thickness is 0.3 mm that is equivalent to pixel size of the flat panel detector (FPD). We conducted quantitative verification to establish the measurement method of the section thickness. The edge method is a useful technique as well as the wire and bead method for grasping basic characteristics of an imaging system.

  6. Assessment of Nuclear Fuels using Radiographic Thickness Measurement Method

    Energy Technology Data Exchange (ETDEWEB)

    Muhammad Abir; Fahima Islam; Hyoung Koo Lee; Daniel Wachs

    2014-11-01

    The Convert branch of the National Nuclear Security Administration (NNSA) Global Threat Reduction Initiative (GTRI) focuses on the development of high uranium density fuels for research and test reactors for nonproliferation. This fuel is aimed to convert low density high enriched uranium (HEU) based fuel to high density low enriched uranium (LEU) based fuel for high performance research reactors (HPRR). There are five U.S. reactors that fall under the HPRR category, including: the Massachusetts Institute of Technology Reactor (MITR), the National Bureau of Standards Reactor (NBSR), the Missouri University Research Reactor (UMRR), the Advanced Test Reactor (ATR), and the High Flux Isotope Reactor (HFIR). U-Mo alloy fuel phase in the form of either monolithic or dispersion foil type fuels, such as ATR Full-size In center flux trap Position (AFIP) and Reduced Enrichment for Research and Test Reactor (RERTR), are being designed for this purpose. The fabrication process1 of RERTR is susceptible to introducing a variety of fuel defects. A dependable quality control method is required during fabrication of RERTR miniplates to maintain the allowable design tolerances, therefore evaluating and analytically verifying the fabricated miniplates for maintaining quality standards as well as safety. The purpose of this work is to analyze the thickness of the fabricated RERTR-12 miniplates using non-destructive technique to meet the fuel plate specification for RERTR fuel to be used in the ATR.

  7. Visual and anatomical outcomes following idiopathic macular epiretinal membrane surgery

    International Nuclear Information System (INIS)

    Shahzadi, B.; Rizvi, S.F.; Latif, K.; Naz, S.

    2016-01-01

    To assess the visual and anatomical outcomes following idiopathic macular epiretinal membrane (IERM) surgery. Study Design: Case series. Place and Duration of Study: Layton Rehmatulla Benevolent Trust (L.R.B.T), Free Base Eye Hospital, Karachi, from January 2015 to June 2016. Methodology: Thirty eyes of thirty patients affected with idiopathic macular epiretinal membrane stage 2 were enrolled in this study. They subsequently underwent 23-gauge pars plana vitrectomy (PPV) with epiretinal membrane removal without internal limiting membrane peeling. The visual outcome was measured as improvement in best corrected visual acuity (BCVA) of at least two or more lines on ETDRS chart as compared to preoperative BCVA. The anatomical outcome was measured as decrease in foveal thickness on Spectral Domain-Optical Coherence Tomography (SD-OCT). Patients were followed for a period of 06 months. Results: At the end of follow-ups, 23 (76%) eyes out of 30 gained 2 or more lines of vision. In 05 (16%) eyes, BCVA remained same and only 02 (6.6%) eyes showed worsening of vision. Mean preoperative foveal thickness was 392 ± 20 micro m, whereas mean postoperative thickness was 305 ± 16 micro m with an average decrease of 87 micro m, in foveal thickness. Recurrence of ERM was found to be the most frequent complication. Conclusion: IERM surgery is a safe procedure and beneficial in achieving significant visual acuity improvement and anatomical recovery in the majority of cases. (author)

  8. Manual versus automatic bladder wall thickness measurements: a method comparison study

    NARCIS (Netherlands)

    Oelke, M.; Mamoulakis, C.; Ubbink, D.T.; de la Rosette, J.J.; Wijkstra, H.

    2009-01-01

    Purpose To compare repeatability and agreement of conventional ultrasound bladder wall thickness (BWT) measurements with automatically obtained BWT measurements by the BVM 6500 device. Methods Adult patients with lower urinary tract symptoms, urinary incontinence, or postvoid residual urine were

  9. Triceps skin fold thickness as a measure of body fat in Nigerian

    African Journals Online (AJOL)

    owner

    2012-11-26

    Nov 26, 2012 ... and body fat distribution.2,3 Skin fold thickness measure- ments are a well ... different recognized areas for the measurement of SFT, ..... 'western children.' These .... Asia Pacific J Clin ... sity in children and young people:.

  10. What Is Macular Edema?

    Medline Plus

    Full Text Available ... remains. Macular edema is often a complication of diabetic retinopathy , and is the most common form of ... 2016 Study Compares Eylea, Lucentis and Avastin for Diabetic Macular Edema Jul 17, 2015 Top 5 Risk ...

  11. Macular degeneration (image)

    Science.gov (United States)

    ... macula in the back of the eye. The macula is important for clear central vision, allowing an individual to see fine details. There are two types of macular degeneration, dry and wet. Dry macular degeneration is more ...

  12. What Is Macular Edema?

    Medline Plus

    Full Text Available ... be able to see after vitrectomy surgery for a macular hole? Jan 24, 2016 Can Prolensa drops help a macular hole? Jan 11, 2016 After a person develops ocular histoplasmosis, ...

  13. Measurement of the bremsstrahlung spectra generated from thick ...

    Indian Academy of Sciences (India)

    with those predicted by Monte-Carlo (MC) calculations using PENELOPE code. A close ... done on bremsstrahlung cross-section measurements and many theories have been given for ..... This probability is expected to be maximum for elastic.

  14. A new attempt of measurement film thickness by x-ray diffractometry

    International Nuclear Information System (INIS)

    Kosaka, Masao; Kobayashi, Hideo

    1987-01-01

    In order to make film thickness measurements independent from the property or the structure of the film materials or the substrate, it is needed to adopt instead of directly utilizing the X-ray diffraction intensity, or attenuation information obtained from the substrate or film material, other new methods for measurement. Among the information obtained by X-ray diffraction, if intensity is excluded, others are F.W.H.M. and diffraction angle, only. If it is possible to investigate the film thickness dependency of the diffraction angle, it should be possible to measure the film thickness by diffraction angle. However, since diffraction angle has no film thickness dependency, it cannot be used directly for measurement. However, if we consider the principle of the X-ray diffractometer method, although it may be very slight, the substrate will be eccentric from the revolving center of the goniometer on account of the thickness of the film. If eccentricity occurs, this will cause changes in the diffraction angle. If we set the radius of the goniometer as R, diffraction angle θ, and the eccentricity from the revolving center of the specimen surface X, the deflection angle Δ2θ of 2θ may be expressed by Δ2θ = -2X · COSθ/R Thus, if X is caused by the film thickness, and by measuring the Δ2θ, it will be possible to measure the film thickness. As a result of the experiment, it was found that X-ray diffraction method can be used for the measurement of the film thickness of a few microns or above by utilizing the eccentricity caused by the film thickness. Especially it has the advantage of being able to measure thick films that X-rays will not penetrate, without being influenced by the chemical structure of the film or the substrates. (author)

  15. Quantitative materials analysis of micro devices using absorption-based thickness measurements

    International Nuclear Information System (INIS)

    Sim, L M; Wog, B S; Spowage, A C

    2006-01-01

    Preliminary work in designing an X-ray inspection machine with the capability of providing quantitative thickness analysis based on absorption measurements has been demonstrated. This study attempts to use the gray levels data to investigate the nature and thickness of occluded features and materials within devices. The investigation focused on metallic materials essential to semiconductor and MEMS technologies such as tin, aluminium, copper, silver, iron and zinc. The materials were arranged to simulate different feature thicknesses and sample geometries. The X-ray parameters were varied in-order to modify the X-ray energy spectrum with the aim of optimising the measurement conditions for each sample. The capability of the method to resolve differences in thicknesses was found to be highly dependent on the material. The thickness resolution with aluminium was the poorest due to its low radiographic density. The thickness resolutions achievable for silver and tin were significantly better and of the order of 0.015 mm and 0.025 mm respectively. From the linear relationship between the X-ray attenuation and sample thickness established, the energy dependent linear attenuation coefficient for each material was determined for a series of specific energy spectra. A decrease in the linear attenuation coefficient was observed as the applied voltage and thickness of the material increased. The results provide a platform for the development of a novel absorption-based thickness measurement system that can be optimised for a range of industrial applications

  16. High-throughput measurement of polymer film thickness using optical dyes

    Science.gov (United States)

    Grunlan, Jaime C.; Mehrabi, Ali R.; Ly, Tien

    2005-01-01

    Optical dyes were added to polymer solutions in an effort to create a technique for high-throughput screening of dry polymer film thickness. Arrays of polystyrene films, cast from a toluene solution, containing methyl red or solvent green were used to demonstrate the feasibility of this technique. Measurements of the peak visible absorbance of each film were converted to thickness using the Beer-Lambert relationship. These absorbance-based thickness calculations agreed within 10% of thickness measured using a micrometer for polystyrene films that were 10-50 µm. At these thicknesses it is believed that the absorbance values are actually more accurate. At least for this solvent-based system, thickness was shown to be accurately measured in a high-throughput manner that could potentially be applied to other equivalent systems. Similar water-based films made with poly(sodium 4-styrenesulfonate) dyed with malachite green oxalate or congo red did not show the same level of agreement with the micrometer measurements. Extensive phase separation between polymer and dye resulted in inflated absorbance values and calculated thickness that was often more than 25% greater than that measured with the micrometer. Only at thicknesses below 15 µm could reasonable accuracy be achieved for the water-based films.

  17. CLINICAL AND ELECTROPHYSIOLOGICAL EVALUATION AFTER INTRAVITREAL ZIV-AFLIBERCEPT FOR EXUDATIVE AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    de Oliveira Dias, João Rafael; de Andrade, Gabriel Costa; Kniggendorf, Vinicius Ferreira; Novais, Eduardo Amorim; Maia, André; Meyer, Carsten; Watanabe, Sung Eun Song; Farah, Michel Eid; Rodrigues, Eduardo Büchele

    2017-08-01

    To evaluate the 6-month safety and efficacy of ziv-aflibercept intravitreal injections for treating exudative age-related macular degeneration. Fifteen patients with unilateral exudative age-related macular degeneration were enrolled. The best-corrected visual acuity was measured and spectral domain optical coherence tomography was performed at baseline and monthly. Full-field electroretinography and multifocal electroretinography were obtained at baseline and 4, 13, and 26 weeks after the first injection. All patients received three monthly intravitreal injections of ziv-aflibercept (1.25 mg) followed by as-needed treatment. Between baseline and 26 weeks, the mean logMAR best-corrected visual acuity improved (P = 0.00408) from 0.93 ± 0.4 (20/200) to 0.82 ± 0.5 (20/160) logarithm of the minimum angle of resolution, respectively; the central retinal thickness decreased significantly (P = 0.0007) from 490.3 ± 155.1 microns to 327.9 ± 101.5 microns; the mean total macular volume decreased significantly (P macular responses within the first central 15° showed significantly (P macular volume from baseline to 26 weeks. No retinal toxicity on full-field electroretinography or adverse events occurred during the follow-up period.

  18. What Is Macular Edema?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Macular Edema ... Edema Treatment What Is Macular Edema? Leer en Español: ¿Qué es un edema macular? Dec. 01, 2010 ...

  19. A method to measure the mean thickness and non-uniformity of non-uniform thin film by alpha-ray thickness gauge

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Yoshida, Makoto; Watanabe, Tamaki

    1977-01-01

    The α-ray thickness gauge is used to measure non-destructively the thicknesses of thin films, and up to the present day, a thin film with uniform thickness is only taken up as the object of α-ray thickness gauge. When the thickness is determined from the displacement between the absorption curves in the presence and absence of thin film, the absorption curve must be displaced in parallel. When many uniform particles were dispersed as sample, the shape of the absorption curve was calculated as the sum of many absorption curves corresponding to the thin films with different thicknesses. By the comparison of the calculated and measured absorption curves, the number of particles, or the mean superficial density can be determined. This means the extension of thickness measurement from uniform to non-uniform films. Furthermore, these particle models being applied to non-uniform thin film, the possibility of measuring the mean thickness and non-uniformity was discussed. As the result, if the maximum difference of the thickness was more than 0.2 mg/cm 2 , the nonuniformity was considered to distinguish by the usual equipment. In this paper, an α-ray thickness gauge using the absorption curve method was treated, but one can apply this easily to an α-ray thickness gauge using α-ray energy spectra before and after the penetration of thin film. (auth.)

  20. Thickness measurement for the different metals by using Cs-137 gamma source with gamma transmission technique

    International Nuclear Information System (INIS)

    Bueyuek, B.; Tugrul, B.

    2009-01-01

    The purpose of this study is an experimental analysis of thickness measurement for various metals with the gamma transmission technique using Cs-137 as the radioisotope source. Lead, steel, brass, and aluminum, which are frequently used metals in industry, were chosen for the experiments. As the radioisotope source Cs-137 was preferred for the study since it has long half-life, it is mono energetic, and it penetrates the metals that were studied. Experiments were observed in the constant experimental geometry. Calibration curves for the four metal samples were plotted using the obtained results. To test the plotted calibration curves, counts for determining thickness measurement were collected for each sample and the obtained relative count values were used in conjunction with the plotted calibration curves for each sample to determine its thickness. The thicknesses of the samples have been measured with a micrometer and the results were comparatively analyzed with the measurement results obtained by the gamma transmission technique. The results of the analyses revealed that the thickness measurement values obtained with the gamma transmission technique and the thickness measurement values obtained with the conventional technique significantly converge to each other and the difference between the two values is at an acceptable level. Therefore the reliability of thickness measurements with the gamma transmission technique and the resulting calibration curves have been demonstrated.

  1. Revisited the mathematical derivation wall thickness measurement of pipe for radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, A.R.; Amir, S.M.M. [Non Destructive Testing(NDT) Group, Industrial Technology Div., Malaysian Nuclear Agency, Selangor (Malaysia)

    2007-07-01

    Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to derive the maximum penetration wall thickness a similar approach is used. (authors)

  2. Air-coupled ultrasound for plate thickness measurements

    OpenAIRE

    Waag, Grunde

    2017-01-01

    Non-destructive testing using ultrasound is well established as a technique of inspecting miscellaneous structures and components. Ultrasonic waves propagating in an elastic solid are sensitive to both the material and geometrical properties of the solid. Decades of experience have shown that it is possible to extract these properties from the waves in an efficient and reliable way in a variety of practical measurement settings. Different techniques have been developed over many decades, and ...

  3. ILM peeling in nontractional diabetic macular edema: review and metanalysis.

    Science.gov (United States)

    Rinaldi, M; dell'Omo, R; Morescalchi, F; Semeraro, F; Gambicorti, E; Cacciatore, F; Chiosi, F; Costagliola, C

    2017-10-31

    To evaluate the effect of internal limiting membrane (ILM) peeling during vitrectomy for nontractional diabetic macular edema. PUBMED, MEDLINE and CENTRAL were reviewed using the following terms (or combination of terms): diabetic macular edema, nontractional diabetic macular edema, internal limiting membrane peeling, vitrectomy, Müller cells. Randomized and nonrandomized studies were included. The eligible studies compared anatomical and functional outcomes of vitrectomy with or without ILM peeling for tractional and nontractional diabetic macular edema. Postoperative best-corrected visual acuity and central macular thickness were considered, respectively, the primary and secondary outcomes. Meta-analysis on mean differences between vitrectomy with and without ILM peeling was performed using inverse variance method in random effects. Four studies with 672 patients were eligible for analysis. No significant difference was found between postoperative best-corrected visual acuity or best-corrected visual acuity change of ILM peeling group compared with nonpeeling group. There was no significant difference in postoperative central macular thickness and central macular thickness reduction between the two groups. The visual acuity outcomes in patients affected by nontractional diabetic macular edema using pars plana vitrectomy with ILM peeling versus no ILM peeling were not significantly different. A larger prospective and randomized study would be necessary.

  4. Selection of the ''best'' model for converting beta backscatter count readings into thickness measurements

    International Nuclear Information System (INIS)

    Smiriga, N.G.

    1976-01-01

    This report compares two models for converting beta backscatter count readings into thickness measurements. The necessary formulas to be used in an unweighted and weighted regression analysis are listed. The question of whether one should perform a regression analysis using the five available standard thicknesses or whether one should, in addition to these standard thicknesses, use zero as a standard thickness is decided. A weighted regression analysis is compared with an unweighted one for each model. The ''best'' model is selected, and the conclusions of the analysis are presented

  5. Modification of the laser triangulation method for measuring the thickness of optical layers

    Science.gov (United States)

    Khramov, V. N.; Adamov, A. A.

    2018-04-01

    The problem of determining the thickness of thin films by the method of laser triangulation is considered. An expression is derived for the film thickness and the distance between the focused beams on the photo detector. The possibility of applying the chosen method for measuring thickness is in the range [0.1; 1] mm. We could resolve 2 individual light marks for a minimum film thickness of 0.23 mm. We resolved with the help of computer processing of photos with a resolution of 0.10 mm. The obtained results can be used in ophthalmology for express diagnostics during surgical operations on the corneal layer.

  6. Sonographic Measurement of AP Diameter and Wall Thickness of the Gallbladder

    International Nuclear Information System (INIS)

    Chung, S.K.; Lee, J. S.; Huh, S. J.; Baek, I. S.

    1982-01-01

    Call bladder size and wall thickness are important in the assessment of the pathologic condition. Authors have measured AP diameter of gallbladder and evaluated the change of all thickness between fasting and postprandial state. The results were as follows: 1. The mean of AP diameter was 2.18+0.49cm 2. The wall thickness was 2.7+0.6mm in fasting state and 3.3+0.8mm after meal. 3. The increase of wall thickness after fat meal was significant statistically(p<.001)

  7. The determination of the pressure-viscosity coefficient of two traction oils using film thickness measurements

    NARCIS (Netherlands)

    Leeuwen, van H.J.

    2010-01-01

    The pressure-viscosity coefficients of two commercial traction fluids are determined by fitting calculation results on accurate film thickness measurements, obtained at a wide range of speeds, and different temperatures. Film thickness values are calculated using a numerical method and approximation

  8. A semi-automated method for measuring thickness and white matter ...

    African Journals Online (AJOL)

    A semi-automated method for measuring thickness and white matter integrity of the corpus callosum. ... and interhemispheric differences. Future research will determine normal values for age and compare CC thickness with peripheral white matter volume loss in large groups of patients, using the semiautomated technique.

  9. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity

    Directory of Open Access Journals (Sweden)

    Adebisi Bisi-Balogun

    2016-04-01

    Full Text Available This study aimed to determine the relative and absolute reliability of ultrasound (US measurements of the thickness and echogenicity of the plantar fascia (PF at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  10. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity.

    Science.gov (United States)

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-04-13

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  11. A semi-empirical method for measuring thickness of pipe-wall using gamma scattering technique

    International Nuclear Information System (INIS)

    Vo Hoang Nguyen; Hua Tuyet Le; Le Dinh Minh Quan; Hoang Duc Tam; Le Bao Tran; Tran Thien Thanh; Tran Nguyen Thuy Ngan; Chau Van Tao; VNUHCM-University of Science, Ho Chi Minh City; Huynh Dinh Chuong

    2016-01-01

    In this work, we propose a semi-empirical method for determining the thickness of pipe-wall, of which the determination is performed by combining the experimental and Monte Carlo simulation data. The testing measurements show that this is an efficient method to measure the thickness of pipe-wall. In addition, this work also shows that it could use a NaI(Tl) scintillation detector and a low activity source to measure the thickness of pipe-wall, which is simple, quick and high accuracy method. (author)

  12. Experimental Influences in the Accurate Measurement of Cartilage Thickness in MRI.

    Science.gov (United States)

    Wang, Nian; Badar, Farid; Xia, Yang

    2018-01-01

    Objective To study the experimental influences to the measurement of cartilage thickness by magnetic resonance imaging (MRI). Design The complete thicknesses of healthy and trypsin-degraded cartilage were measured at high-resolution MRI under different conditions, using two intensity-based imaging sequences (ultra-short echo [UTE] and multislice-multiecho [MSME]) and 3 quantitative relaxation imaging sequences (T 1 , T 2 , and T 1 ρ). Other variables included different orientations in the magnet, 2 soaking solutions (saline and phosphate buffered saline [PBS]), and external loading. Results With cartilage soaked in saline, UTE and T 1 methods yielded complete and consistent measurement of cartilage thickness, while the thickness measurement by T 2 , T 1 ρ, and MSME methods were orientation dependent. The effect of external loading on cartilage thickness is also sequence and orientation dependent. All variations in cartilage thickness in MRI could be eliminated with the use of a 100 mM PBS or imaged by UTE sequence. Conclusions The appearance of articular cartilage and the measurement accuracy of cartilage thickness in MRI can be influenced by a number of experimental factors in ex vivo MRI, from the use of various pulse sequences and soaking solutions to the health of the tissue. T 2 -based imaging sequence, both proton-intensity sequence and quantitative relaxation sequence, similarly produced the largest variations. With adequate resolution, the accurate measurement of whole cartilage tissue in clinical MRI could be utilized to detect differences between healthy and osteoarthritic cartilage after compression.

  13. Subconjunctival sirolimus in the treatment of diabetic macular edema.

    Science.gov (United States)

    Krishnadev, Nupura; Forooghian, Farzin; Cukras, Catherine; Wong, Wai; Saligan, Leorey; Chew, Emily Y; Nussenblatt, Robert; Ferris, Frederick; Meyerle, Catherine

    2011-11-01

    Diabetic macular edema (DME) is a leading cause of blindness in the developed world. Sirolimus has been shown to inhibit the production, signaling, and activity of many growth factors relevant to the development of diabetic retinopathy. This phase I/II study assesses the safety of multiple subconjunctival sirolimus injections for the treatment of DME, with some limited efficacy data. In this phase I/II prospective, open-label pilot study, five adult participants with diabetic macular edema involving the center of the fovea and best-corrected ETDRS visual acuity score of ≤74 letters (20/32 or worse) received 20 μl (440 μg) of subconjunctival sirolimus at baseline, month 2 and every 2 months thereafter, unless there was resolution of either retinal thickening on OCT or leakage on fluorescein angiography. Main outcome measures included best-corrected visual acuity and central retinal thickness on OCT at 6 months and 1 year, as well as safety outcomes. Repeated subconjunctival sirolimus injections were well-tolerated, with no significant drug-related adverse events. There was no consistent treatment effect related to sirolimus; one participant experienced a 2-line improvement in visual acuity and 2 log unit decrease in retinal thickness at 6 months and 1 year, two remained essentially stable, one had stable visual acuity but improvement of central retinal thickness of 1 and 3 log units at 6 months and 1 year respectively, and one had a 2-line worsening of visual acuity and a 1 log unit increase in retinal thickness at 6 months and 1 year. Results in the fellow eyes with diabetic macular edema, not treated with sirolimus, were similar. Subconjunctival sirolimus appears safe to use in patients with DME. Assessment of possible treatment benefit will require a randomized trial.

  14. In situ measurement of low-Z material coating thickness on high Z substrate for tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, D., E-mail: dmueller@pppl.gov; Roquemore, A. L.; Jaworski, M.; Skinner, C. H.; Miller, J.; Creely, A. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Raman, P.; Ruzic, D. [Department of Nuclear, Plasma, and Radiological Engineering, Center for Plasma Material Interaction, University of Illinois, Urbana, Illinois 61801 (United States)

    2014-11-15

    Rutherford backscattering of energetic particles can be used to determine the thickness of a coating of a low-Z material over a heavier substrate. Simulations indicate that 5 MeV alpha particles from an {sup 241}Am source can be used to measure the thickness of a Li coating on Mo tiles between 0.5 and 15 μm thick. Using a 0.1 mCi source, a thickness measurement can be accomplished in 2 h of counting. This technique could be used to measure any thin, low-Z material coating (up to 1 mg/cm{sup 2} thick) on a high-Z substrate, such as Be on W, B on Mo, or Li on Mo. By inserting a source and detector on a moveable probe, this technique could be used to provide an in situ measurement of the thickness of Li coating on NSTX-U Mo tiles. A test stand with an alpha source and an annular solid-state detector was used to investigate the measurable range of low-Z material thicknesses on Mo tiles.

  15. Reliability assessment for thickness measurements of pipe wall using probability of detection

    International Nuclear Information System (INIS)

    Nakamoto, Hiroyuki; Kojima, Fumio; Kato, Sho

    2013-01-01

    This paper proposes a reliability assessment method for thickness measurements of pipe wall using probability of detection (POD). Thicknesses of pipes are measured by qualified inspectors with ultrasonic thickness gauges. The inspection results are affected by human factors of the inspectors and include some errors, because the inspectors have different experiences and frequency of inspections. In order to ensure reliability for inspection results, first, POD evaluates experimental results of pipe-wall thickness inspection. We verify that the results have differences depending on inspectors including qualified inspectors. Second, two human factors that affect POD are indicated. Finally, it is confirmed that POD can identify the human factors and ensure reliability for pipe-wall thickness inspections. (author)

  16. Measurement of the residual stress distribution in a thick pre-stretched aluminum plate

    Science.gov (United States)

    Yuan, S. X.; Li, X. Q.; M, S.; Zhang, Y. C.; Gong, Y. D.

    2008-12-01

    Thick pre-stretched aluminum alloy plates are widely used in aircraft, while machining distortion caused by initial residual stress release in thick plates is a common and serious problem. To reduce the distortion, the residual stress distribution in thick plate must be measured. According to the characteristics of the thick pre-stretched aluminum alloy plate, based the elastic mechanical theory, this article deduces the modified layer-removal strain method adapting two different strain situations, which are caused by tensile and compressive stress. To validate this method, the residual stresses distribution along the thick direction of plate 2D70T351 is measured by this method, it is shown that the new method deduced in this paper is simple and accurate, and is very useful in engineering.

  17. Nondestructive web thickness measurement of micro-drills with an integrated laser inspection system

    Science.gov (United States)

    Chuang, Shui-Fa; Chen, Yen-Chung; Chang, Wen-Tung; Lin, Ching-Chih; Tarng, Yeong-Shin

    2010-09-01

    Nowadays, the electric and semiconductor industries use numerous micro-drills to machine micro-holes in printed circuit boards. The measurement of web thickness of micro-drills, a key parameter of micro-drill geometry influencing drill rigidity and chip-removal ability, is quite important to ensure quality control. Traditionally, inefficiently destructive measuring method is adopted by inspectors. To improve quality and efficiency of the web thickness measuring tasks, a nondestructive measuring method is required. In this paper, based on the laser micro-gauge (LMG) and laser confocal displacement meter (LCDM) techniques, a nondestructive measuring principle of web thickness of micro-drills is introduced. An integrated laser inspection system, mainly consisting of a LMG, a LCDM and a two-axis-driven micro-drill fixture device, was developed. Experiments meant to inspect web thickness of micro-drill samples with a nominal diameter of 0.25 mm were conducted to test the feasibility of the developed laser inspection system. The experimental results showed that the web thickness measurement could achieve an estimated repeatability of ± 1.6 μm and a worst repeatability of ± 7.5 μm. The developed laser inspection system, combined with the nondestructive measuring principle, was able to undertake the web thickness measuring tasks for certain micro-drills.

  18. Measurement of facial soft tissues thickness using 3D computed tomographic images

    International Nuclear Information System (INIS)

    Jeong, Ho Gul; Kim, Kee Deog; Shin, Dong Won; Hu, Kyung Seok; Lee, Jae Bum; Park, Hyok; Park, Chang Seo; Han, Seung Ho

    2006-01-01

    To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. There were no statistically significant differences between the direct measurements and those using the 3D images(p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissue thickness more easily in forensic science and anthropology

  19. Measurement of facial soft tissues thickness using 3D computed tomographic images

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ho Gul; Kim, Kee Deog; Shin, Dong Won; Hu, Kyung Seok; Lee, Jae Bum; Park, Hyok; Park, Chang Seo [Yonsei Univ. Hospital, Seoul (Korea, Republic of); Han, Seung Ho [Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2006-03-15

    To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. There were no statistically significant differences between the direct measurements and those using the 3D images(p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissue thickness more easily in forensic science and anthropology.

  20. The study of thickness and density compensation of neutron-measuring moisture system on conveyor belt

    International Nuclear Information System (INIS)

    Jia Wenbao; Su Tongling; Zhang Xiaomin; Xu Zhongfeng

    1999-01-01

    The neutron-measuring transmission moisture system on the conveyer belt is systematically studied. A method of density and thickness compensation has been used to carryout the on-line measurements of the moisture of the unshaped, discontinuous and irregular moving matter. At the same time, the thickness weighed average method is employed to modify the prompt moisture at a fixed time, and to improve the accuracy of measuring the moisture. The experimental data show that the measurement errors are within ±2.5% when the thickness is between 2 cm and 16 cm and the water percentage is between 6% and 16%. The errors can reach 0.2% if thickness weighed average for moving matter lasts for a long time

  1. Automatic measuring system of zirconium thickness for zirconium liner cladding tubes

    International Nuclear Information System (INIS)

    Matsui, K.; Yamaguchi, H.; Hiroshima, T.; Sakamoto, T.; Murayama, R.

    1985-01-01

    An automatic system of pure zirconium liner thickness for zirconium-zircaloy cladding tubes has been successfully developed. The system consists of three parts. (1) An ultrasonic thickness measuring method for mother tubes before cold rolling. (2) An electromagnetic thickness measuring method for the manufactured tubes. (3) An image processing method for the cross sectional view of the manufactured cut tube samples. In Japanese nuclear industry, zirconium-zircaloy cladding tubes have been tested in order to realize load following operation in the atomic power plant. In order to provide for the practical use in the near future, Sumitomo Metal Industries, Ltd. has been studied and established the practical manufacturing process of the zirconium liner cladding tubes. The zirconium-liner cladding tube is a duplex tube comprising an inner layer of pure zirconium bonded to zircaloy metallurgically. The thickness of the pure zirconium is about 10 % of the total wall thickness. Several types of the automatic thickness measuring methods have been investigated instead of the usual microscopic viewing method in which the liner thickness is measured by the microscopic cross sectional view of the cut tube samples

  2. The use of radiography for thickness measurement and corrosion monitoring in pipes

    International Nuclear Information System (INIS)

    Edalati, K.; Rastkhah, N.; Kermani, A.; Seiedi, M.; Movafeghi, A.

    2006-01-01

    In this study of pipes of 150 mm diameters, thickness ranging from 4.2 to 15.0 mm was determined by using two radiography techniques: tangential radiography and double wall radiography. It was concluded that thickness losses of 10%, 20% and 50% could be determined by these methods. Formulae were developed for the double wall radiography method with a high precision of thickness measurement for non-insulated pipes. The precision was comparable with ultrasonic measurement results. Corrosion type and corrosion surface could be observed by these methods. Internal or external corrosion produced different effects in tangential radiography. Insulation removal was not necessary using the radiographic techniques

  3. The use of radiography for thickness measurement and corrosion monitoring in pipes

    Energy Technology Data Exchange (ETDEWEB)

    Edalati, K. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of)]. E-mail: NDT99@aeoi.org.ir; Rastkhah, N. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Kermani, A. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Seiedi, M. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Movafeghi, A. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of)

    2006-10-15

    In this study of pipes of 150 mm diameters, thickness ranging from 4.2 to 15.0 mm was determined by using two radiography techniques: tangential radiography and double wall radiography. It was concluded that thickness losses of 10%, 20% and 50% could be determined by these methods. Formulae were developed for the double wall radiography method with a high precision of thickness measurement for non-insulated pipes. The precision was comparable with ultrasonic measurement results. Corrosion type and corrosion surface could be observed by these methods. Internal or external corrosion produced different effects in tangential radiography. Insulation removal was not necessary using the radiographic techniques.

  4. Preliminary study of Conbercept injected intravitreally for the treatment of wet age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Ying Qin

    2017-08-01

    Full Text Available AIM:To observe the preliminary efficacy of conbercept injected intravitreally for the treatment of wet age-related macular degeneration(wAMD.METHODS:Seventeen wAMD patients(18 eyeswere selected to receive conbercept injection. All patients were given a single conbercept injection every month, 3 times. Before and after 1, 2, 3mo of the injection, the best corrected visual acuity(BCVA, intraocular pressure(IOP, measured by Non-contact tonometer, fundus photography, fundus fluorescein angiography(FFA, indocyanine green angiography(ICG, optical coherence tomography(OCTexamination and the complications incidence were compared.RESULTS:Three months after conbercept injection, the BCVA improved in 15 eyes(83%, stable in 3 eyes(17%. Before treatment, the average central macular thickness was 421.72±54.43μm, at 1 and 2 and 3mo after treatment, the average central macular thickness was 337.89±25.88μm, 293.56±26.87μm, 266.89±19.10μm respectively. There were significant differences compared with before and after injection(PCONCLUSION:Intravitreal injection conbercept for wAMD can significantly improve the visual function, reduce the macular edema and the leakage with higher safety and less complications. However the prolonged efficacy needs further observation.

  5. Quantitative CT measures of emphysema and airway wall thickness are related to D(L)CO

    DEFF Research Database (Denmark)

    Grydeland, Thomas B; Thorsen, Einar; Dirksen, Asger

    2011-01-01

    There is limited knowledge on the relationship between diffusing capacity of the lung for carbon monoxide (D(L)CO) and quantitative computed tomography (CT) measures of emphysema and airway wall thickness.......There is limited knowledge on the relationship between diffusing capacity of the lung for carbon monoxide (D(L)CO) and quantitative computed tomography (CT) measures of emphysema and airway wall thickness....

  6. Ellipsometry measurements of thickness of oxide and water layers on spherical and flat silicon surfaces

    International Nuclear Information System (INIS)

    Kenny, M.J.; Netterfield, R.; Wielunski, L.S.

    1998-01-01

    Full text: Ellipsometry has been used to measure the thickness of oxide layers on single crystal silicon surfaces, both flat and spherical and also to measure the extent of adsorption of moisture on the surface as a function of partial water vapour pressure. The measurements form part of an international collaborative project to make a precise determination of the Avogadro constant (ΔN A /N A -8 ) which will then be used to obtain an absolute definition of the kilogram, rather than one in terms of an artefact. Typically the native oxide layer on a cleaned silicon wafer is about 2 nm thick. On a polished sphere this oxide layer is typically 8 to 10 nm thick, the increased thickness being attributed to parameters related to the polishing process. Ellipsometry measurements on an 89 mm diameter polished silicon sphere at both VUW and CSIRO indicated a SiO 2 layer at 7 to 10 nm thick. It was observed that this thickness varied regularly. The crystal orientation of the sphere was determined using electron patterns generated from an electron microscope and the oxide layer was then measured through 180 arcs of great circles along (110) and (100) planes. It was observed that the thickness varied systematically with orientation. The minimum thickness was 7.4 nm at the axis (softest direction in silicon) and the greatest thickness was 9.5 nm at the axis (hardest direction in silicon). This is similar to an orientation dependent cubic pattern which has been observed to be superimposed on polished silicon spheres. At VUW, the sphere was placed in an evacuated bell jar and the ellipsometry signal was observed as the water vapour pressure was progressively increased up to saturation. The amount of water vapour adsorbed at saturation was one or two monolayers, indicating that the sphere does not wet

  7. Measurement of sea ice thickness using electromagnetic sounding; Denji tansaho wo mochiita kaihyoatsu no keisoku

    Energy Technology Data Exchange (ETDEWEB)

    Kawauchi, K; Suzuki, I; Goto, N [Muroran Institute of Technology, Hokkaido (Japan); Hoshiyama, K

    1997-10-22

    Thickness of sea ice is measured by an electromagnetic method making use of the peculiarities of sea ice. Sea ice floats on the seawater (saline water), and the result is two horizontal layers greatly different from each other in conductivity, with seawater being highly conductive and ice being non-conductive. A study is conducted on Lake Kumatori, a saline lake in Abashiri City, in which effort a board of naturally frozen sea ice and a board of sea ice allowed to form on the sea surface at a spot from which ice has been removed are examined. A portable electromagnetic probe EM38 of GEONICS Company is employed to perform measurement in a horizontal dipole mode. To determine the relationship between the obtained conductivity measurements and sea ice thickness, holes are bored in the sea ice boards for the measurement of their thickness for the formulation of an experimental regression equation. Measurements along the traverse line 1 and traverse line 3 are converted into sea ice thickness by use of the experimental regression equation, and the result is that ice thickness is the greatest near the quay growing thinner away from the shore. The study shows that sea ice thickness may be measured accurately by electromagnetic probing. 3 refs., 10 figs.

  8. Macular thinning in prediabetes or type 2 diabetes without diabetic retinopathy: the Maastricht Study.

    Science.gov (United States)

    De Clerck, Eline E B; Schouten, Jan S A G; Berendschot, Tos T J M; Goezinne, Fleur; Dagnelie, Pieter C; Schaper, Nicolaas C; Schram, Miranda T; Stehouwer, Coen D A; Webers, Carroll A B

    2018-03-01

    To assess macular thinning in individuals with prediabetes or type 2 diabetes without diabetic retinopathy (DM2 w/o DR) compared with individuals with normal glucose metabolism (NGM). Using spectral domain optical coherence tomography (SD-OCT), we measured macular thickness in six subfields as defined by the Early Treatment Diabetic Retinopathy Study (ETDRS) in 1838 participants from The Maastricht Study, a population-based cohort study (mean age 59 ± 8 years, 49% men, 1087 NGM, 279 prediabetes, 472 DM2 w/o DR). Multivariable linear regression was used to assess the association between macular thickness and glucose metabolism status. After adjustment for age, sex and spherical equivalent, individuals with prediabetes showed a significant decrease in pericentral superior macular thickness [β = -2.14 μm (95% confidence interval (CI): -4.24 to -0.03), p < 0.05] compared with individuals with NGM. In individuals with DM2 w/o DR, the fovea [β = -4.05 μm (95% CI: -6.30 to -1.79), p < 0.001] and the four pericentral quadrants (range: β = -4.64 to -5.29 μm, p < 0.001) were significantly thinner compared with individuals with NGM. There was a significant linear trend of macular thinning with severity of glucose metabolism status in five subfields (p < 0.001). Macular thickness is reduced in prediabetes and a greater reduction occurs in DM2, even before DR is clinically present. About half of the thinning observed in DM2 w/o DR was already found in prediabetes. Generalized thinning of the macula could be related to thinning of the temporal side of the optic nerve head through the connecting papillo-macular bundle. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Intravitreal bevacizumab (Avastin) for neovascular age-related macular degeneration in treatment-naive patients

    DEFF Research Database (Denmark)

    Pedersen, Karen Bjerg; Sjølie, Anne Katrin; Møller, Flemming

    2008-01-01

    Abstract. Purpose: To report the effects of intravitreal bevacizumab (Avastin((R))) in treatment-naive patients with exudative age-related macular degeneration (ARMD) assessed by visual acuity (VA), optical coherence tomography (OCT) and contrast sensitivity. Methods: A prospective, uncontrolled...... was not statistically significant. Mean macular thickness decreased significantly from baseline to all follow-up examinations (P Macular thickness improved significantly at all time...

  10. In situ non-destructive measurement of biofilm thickness and topology in an interferometric optical microscope.

    Science.gov (United States)

    Larimer, Curtis; Suter, Jonathan D; Bonheyo, George; Addleman, Raymond Shane

    2016-06-01

    Biofilms are ubiquitous and impact the environment, human health, dental hygiene, and a wide range of industrial processes. Biofilms are difficult to characterize when fully hydrated, especially in a non-destructive manner, because of their soft structure and water-like bulk properties. Herein a method of measuring and monitoring the thickness and topology of live biofilms of using white light interferometry is described. Using this technique, surface morphology, surface roughness, and biofilm thickness were measured over time without while the biofilm continued to grow. The thickness and surface topology of a P. putida biofilm were monitored growing from initial colonization to a mature biofilm. Measured thickness followed expected trends for bacterial growth. Surface roughness also increased over time and was a leading indicator of biofilm growth. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Microscopic image processing system for measuring nonuniform film thickness profiles: Image scanning ellipsometry

    International Nuclear Information System (INIS)

    Liu, A.H.; Plawsky, J.L.; Wayner, P.C. Jr.

    1993-01-01

    The long-term objective of this research program is to determine the stability and heat transfer characteristics of evaporating thin films. The current objective is to develop and use a microscopic image-processing system (IPS) which has two parts: an image analyzing interferometer (IAI) and an image scanning ellipsometer (ISE). The primary purpose of this paper is to present the basic concept of ISE, which is a novel technique to measure the two dimensional thickness profile of a non-uniform, thin film, from several nm up to several μm, in a steady state as well as in a transient state. It is a full-field imaging technique which can study every point on the surface simultaneously with high spatial resolution and thickness sensitivity, i.e., it can measure and map the 2-D film thickness profile. The ISE was tested by measuring the thickness profile and the refractive index of a nonuniform solid film

  12. Lead Equivalent Thickness Measurement for Mixed Compositions of Barium Plaster Block

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Muhammad Isa; Nur Shahriza Zainuddin; Mohd Khairusalih Md Zin; Shahrul Azlan Azizan

    2016-01-01

    Measurement of lead equivalent thickness for ionizing radiation exposure room wall shall be performed as stated in Malaysian Standard MS 838. A few numbers of sample blocks with different mixture of barium plaster compositions based and varies certain thickness as a shielding material for exposure room wall belong to a local company were tested by using Cs-137, Co-60 and Am-241 with different activities . Radiations passed through the samples were detected with calibrated survey meter. The distance between radiation source and the detector is about 40 cm. Lead uniformity test on the samples was also determined at three labeled points on the samples. Lead equivalent thicknesses for the samples were evaluated based on a calibration graph that was plotted with lead sheets and with the radiation sources. Results shown that lead equivalent thickness for the samples with same actual physical thickness represent different values for different sources. (author)

  13. Absolute Thickness Measurements on Coatings Without Prior Knowledge of Material Properties Using Terahertz Energy

    Science.gov (United States)

    Roth, Don J.; Cosgriff, Laura M.; Harder, Bryan; Zhu, Dongming; Martin, Richard E.

    2013-01-01

    This study investigates the applicability of a novel noncontact single-sided terahertz electromagnetic measurement method for measuring thickness in dielectric coating systems having either dielectric or conductive substrate materials. The method does not require knowledge of the velocity of terahertz waves in the coating material. The dielectric coatings ranged from approximately 300 to 1400 m in thickness. First, the terahertz method was validated on a bulk dielectric sample to determine its ability to precisely measure thickness and density variation. Then, the method was studied on simulated coating systems. One simulated coating consisted of layered thin paper samples of varying thicknesses on a ceramic substrate. Another simulated coating system consisted of adhesive-backed Teflon adhered to conducting and dielectric substrates. Alumina samples that were coated with a ceramic adhesive layer were also investigated. Finally, the method was studied for thickness measurement of actual thermal barrier coatings (TBC) on ceramic substrates. The unique aspects and limitations of this method for thickness measurements are discussed.

  14. Hyaline cartilage thickness in radiographically normal cadaveric hips: comparison of spiral CT arthrographic and macroscopic measurements.

    Science.gov (United States)

    Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis

    2007-02-01

    To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.

  15. Scanning laser polarimetry retinal nerve fiber layer thickness measurements after LASIK.

    Science.gov (United States)

    Zangwill, Linda M; Abunto, Teresa; Bowd, Christopher; Angeles, Raymund; Schanzlin, David J; Weinreb, Robert N

    2005-02-01

    To compare retinal nerve fiber layer (RNFL) thickness measurements before and after LASIK. Cohort study. Twenty participants undergoing LASIK and 14 normal controls. Retinal nerve fiber layer thickness was measured before LASIK and approximately 3 months after surgery in one eye each of 20 patients using a scanning laser polarimeter (GDx Nerve Fiber Analyzer) with fixed corneal compensation (FCC), one with variable corneal compensation (GDx VCC), and optical coherence tomography (OCT). Fourteen normal controls also were tested at baseline and approximately 3 months later. Retinal nerve fiber layer thicknesses measured with the GDx FCC, GDx VCC, and OCT. At baseline, mean (95% confidence interval [CI]) RNFL thicknesses for the GDx FCC, GDx VCC, and OCT were 78.1 microm (72.2-83.9), 54.3 microm (52.7-56.0), and 96.8 microm (93.2-100.5), respectively. In both LASIK and control groups, there were no significant changes between baseline and follow-up examinations in GDx VCC and OCT RNFL thickness measurements globally or in the superior and inferior quadrants (mean change, FCC measurements between baseline and follow-up. In LASIK patients, significant reductions were observed in GDx FCC RNFL measurements. Average absolute values of the mean (95% CI) change in thickness were 12.4 microm (7.7-17.2), 15.3 microm (9.6-20.9), and 12.9 microm (7.6-18.1) for GDx FCC RNFL measurements superiorly, inferiorly, and globally, respectively (all Ps FCC RNFL thickness measurements after LASIK is a measurement artifact and is most likely due to erroneous compensation for corneal birefringence. With scanning laser polarimetry, it is mandatory to compensate individually for change in corneal birefringence after LASIK to ensure accurate RNFL assessment.

  16. Analysis and Comparison of Thickness and Bending Measurements from Fabric Touch Tester (FTT and Standard Methods

    Directory of Open Access Journals (Sweden)

    Musa Atiyyah Binti Haji

    2018-03-01

    Full Text Available Fabric Touch Tester (FTT is a relatively new device from SDL Atlas to determine touch properties of fabrics. It simultaneously measures 13 touch-related fabric physical properties in four modules that include bending and thickness measurements. This study aims to comparatively analyze the thickness and bending measurements made by the FTT and the common standard methods used in the textile industry. The results obtained with the FTT for 11 different fabrics were compared with that of standard methods. Despite the different measurement principle, a good correlation was found between the two methods used for the assessment of thickness and bending. As FTT is a new tool for textile comfort measurement and no standard yet exists, these findings are essential to determine the reliability of the measurements and how they relate to the well-established standard methods.

  17. Ultrasonographic measurement of the axillary recess thickness in an asymptomatic shoulder

    Directory of Open Access Journals (Sweden)

    Gi-Young Park

    2017-04-01

    Full Text Available Purpose The purpose of this study was to measure the axillary recess (AR thickness in an asymptomatic shoulder by using ultrasonography (US and to analyze the factors affecting it. Methods We recruited 141 patients (52 males; 89 females; age, 57.7±9.9 years with unilateral shoulder pain and performed US on the unaffected shoulder. Two physiatrists measured the AR thickness of the unaffected shoulder independently. All patients were examined in an upright sitting position with 90° shoulder abduction. The ultrasonographic transducer was placed longitudinally on the mid-axillary line and along the long axis of the humeral shaft. The factors affecting the AR thickness values were analyzed, and intra-class correlation coefficients were used for assessing the reproducibility of each measurement. Results The intrarater reliability values for the two physiatrists were 0.98 and 0.96, respectively. The inter-rater reliability of the mean AR thickness measurements was 0.91. The mean AR thickness in all subjects, males, and females was 2.8±0.6 mm, 3.1±0.6 mm, and 2.6±0.5 mm (P<0.01, respectively. No difference between the left and the right sides (males, P=0.086; females, P=0.535 or between the dominant and the non-dominant sides (males, P=0.173; female, P=0.244 was found. The AR thickness correlated positively with the height (r=0.313, P<0.01 and the weight (r=0.319, P<0.01. However, it did not correlate with the body mass index (r=0.152, P=0.077 or the age (r=-0.056, P=0.515. Conclusion US measurements of the AR thickness in asymptomatic shoulders demonstrated excellent intrarater and inter-rater reliabilities. The AR thickness showed anatomical variation with sex, height, and weight.

  18. Ultrasonographic measurement of the axillary recess thickness in an asymptomatic shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Park, Gi Young; Lee, Jin Hoon; Kwon, Dae Gil [Dept. of Rehabilitation Medicine, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of)

    2017-04-15

    The purpose of this study was to measure the axillary recess (AR) thickness in an asymptomatic shoulder by using ultrasonography (US) and to analyze the factors affecting it. We recruited 141 patients (52 males; 89 females; age, 57.7±9.9 years) with unilateral shoulder pain and performed US on the unaffected shoulder. Two physiatrists measured the AR thickness of the unaffected shoulder independently. All patients were examined in an upright sitting position with 90° shoulder abduction. The ultrasonographic transducer was placed longitudinally on the mid-axillary line and along the long axis of the humeral shaft. The factors affecting the AR thickness values were analyzed, and intra-class correlation coefficients were used for assessing the reproducibility of each measurement. The intrarater reliability values for the two physiatrists were 0.98 and 0.96, respectively. The inter-rater reliability of the mean AR thickness measurements was 0.91. The mean AR thickness in all subjects, males, and females was 2.8±0.6 mm, 3.1±0.6 mm, and 2.6±0.5 mm (P<0.01), respectively. No difference between the left and the right sides (males, P=0.086; females, P=0.535) or between the dominant and the non-dominant sides (males, P=0.173; female, P=0.244) was found. The AR thickness correlated positively with the height (r=0.313, P<0.01) and the weight (r=0.319, P<0.01). However, it did not correlate with the body mass index (r=0.152, P=0.077) or the age (r=-0.056, P=0.515). US measurements of the AR thickness in asymptomatic shoulders demonstrated excellent intrarater and inter-rater reliabilities. The AR thickness showed anatomical variation with sex, height, and weight.

  19. Interventions for the treatment of uveitic macular edema: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Karim R

    2013-06-01

    Full Text Available Rushmia Karim,1 Evripidis Sykakis,2 Susan Lightman,3 Samantha Fraser-Bell4 1Faculty of Medicine, University of Sydney, Camperdown, NSW, Australia; 2Department of Ophthalmology, Whipps Cross University Hospital, 3UCL Institute of Ophthalmology and Moorfields Eye Hospital, London, UK; 4University of Sydney, Clinical Ophthalmology and Eye Health, Sydney Adventist Hospital Clinical School, Sydney, NSW, Australia Background: Uveitic macular edema is the major cause of reduced vision in eyes with uveitis. Objectives: To assess the effectiveness of interventions in the treatment of uveitic macular edema. Search strategy: Cochrane Central Register of Controlled Trials, Medline, and Embase. There were no language or data restrictions in the search for trials. The databases were last searched on December 1, 2011. Reference lists of included trials were searched. Archives of Ophthalmology, Ophthalmology, Retina, the British Journal of Ophthalmology, and the New England Journal of Medicine were searched for clinical trials and reviews. Selection criteria: Participants of any age and sex with any type of uveitic macular edema were included. Early, chronic, refractory, or secondary uveitic macular edema were included. We included trials that compared any interventions of any dose and duration, including comparison with another treatment, sham treatment, or no treatment. Data collection and analysis: Best-corrected visual acuity and central macular thickness were the primary outcome measures. Secondary outcome data including adverse effects were collected. Conclusion: More results from randomized controlled trials with long follow-up periods are needed for interventions for uveitic macular edema to assist in determining the overall long-term benefit of different treatments. The only intervention with sufficiently robust randomized controlled trials for a meta-analysis was acetazolamide, which was shown to be ineffective in improving vision in eyes with uveitic

  20. Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

    Energy Technology Data Exchange (ETDEWEB)

    Kim, No Hyu; Lee, Sang Soon [Korea University of Technology and Education, Cheonan (Korea, Republic of)

    2003-12-15

    This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process

  1. Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

    International Nuclear Information System (INIS)

    Kim, No Hyu; Lee, Sang Soon

    2003-01-01

    This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process

  2. Error Analysis of Ceramographic Sample Preparation for Coating Thickness Measurement of Coated Fuel Particles

    International Nuclear Information System (INIS)

    Liu Xiaoxue; Li Ziqiang; Zhao Hongsheng; Zhang Kaihong; Tang Chunhe

    2014-01-01

    The thicknesses of four coatings of HTR coated fuel particle are very important parameters. It is indispensable to control the thickness of four coatings of coated fuel particles for the safety of HTR. A measurement method, ceramographic sample-microanalysis method, to analyze the thickness of coatings was developed. During the process of ceramographic sample-microanalysis, there are two main errors, including ceramographic sample preparation error and thickness measurement error. With the development of microscopic techniques, thickness measurement error can be easily controlled to meet the design requirements. While, due to the coated particles are spherical particles of different diameters ranged from 850 to 1000μm, the sample preparation process will introduce an error. And this error is different from one sample to another. It’s also different from one particle to another in the same sample. In this article, the error of the ceramographic sample preparation was calculated and analyzed. Results show that the error introduced by sample preparation is minor. The minor error of sample preparation guarantees the high accuracy of the mentioned method, which indicates this method is a proper method to measure the thickness of four coatings of coated particles. (author)

  3. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    Science.gov (United States)

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be

  4. Non-Contact Thickness and Profile Measurements of Rolled Aluminium Strip Using EMAT

    International Nuclear Information System (INIS)

    Hobbis, A.; Aruleswaran, A.

    2006-01-01

    Accurate measurement of strip thickness is a very high priority for the aluminium rolled product industry. This paper presents the findings of trials to measure the thickness of aluminium strip using a send-receive, radially polarised Electromagnetic Acoustic Transducer (EMAT). A broadband EMAT system, developed at Warwick University, UK with a centre frequency of approximately 5 MHz and frequency content up to 12 MHz was used. The resultant ultrasonic waveforms have been processed using Fourier analysis. Static measurements of aluminium alloy samples in the thickness range between 0.28 mm to 2.8 mm have been measured using this non-contact approach at stand-offs of up to 2 mm. Measurements across the aluminium strip width to evaluate its profile for quality control was also carried out successfully. Some of the experiments and results obtained are described in detail

  5. Method of accurate thickness measurement of boron carbide coating on copper foil

    Science.gov (United States)

    Lacy, Jeffrey L.; Regmi, Murari

    2017-11-07

    A method is disclosed of measuring the thickness of a thin coating on a substrate comprising dissolving the coating and substrate in a reagent and using the post-dissolution concentration of the coating in the reagent to calculate an effective thickness of the coating. The preferred method includes measuring non-conducting films on flexible and rough substrates, but other kinds of thin films can be measure by matching a reliable film-substrate dissolution technique. One preferred method includes determining the thickness of Boron Carbide films deposited on copper foil. The preferred method uses a standard technique known as inductively coupled plasma optical emission spectroscopy (ICPOES) to measure boron concentration in a liquid sample prepared by dissolving boron carbide films and the Copper substrates, preferably using a chemical etch known as ceric ammonium nitrate (CAN). Measured boron concentration values can then be calculated.

  6. Measurement of Mucosal Thickness in Denture-bearing Area of Edentulous Mandible

    Directory of Open Access Journals (Sweden)

    Jian Dong

    2015-01-01

    Full Text Available Background: The thickness of the alveolar mucosa influences the probability of the occurrence of denture-induced irritations. Thick denture-supporting tissues offer relief from mucosal tenderness and ulcers; however, the uniformity of the thickness across the entire mandibular alveolar mucosa cannot be accurately determined in edentulous patients. This study aimed to assess the mucosal thickness of the denture-bearing area in the edentulous mandible. Methods: Twenty-seven edentulous patients underwent cone-beam computed tomography scanning, wherein the patients wore a record base to retract soft tissues away from the alveolar mucosa. The measured regions were the central incisor (IC, lateral incisor (IL, canine (Ca, first premolar (P1, second premolar (P2, first molar (M1, and second molar (M2 regions. The thickness was measured in the alveolar ridge crest (T, buccal (B1-B4, and lingual (L1-L4 alveolar ridge mucosa. The average thickness of the mucosa at buccal sides (B and lingual sides (L were also assessed. Results: The differences in the mucosal thickness between the left and right sides were not significant. In the Ca-M2 regions, T was the thickest, and L3 was the thinnest of all the measured points in the same regions. L was significantly less than B in posterior regions (P < 0.01. On the other hand, M2 at L4 was thinnest of all the measured regions from Ca to M2 (P < 0.01, and was thicker than IC, IL, P1, and P2 at B2. Conclusions: Since the mucosal thickness of denture-bearing area in the edentulous mandible is not uniform; the tissue surface of the denture base or custom tray should be selectively relieved, which may reduce the risk of denture-induced irritations.

  7. Characterization of the flooding in vertical tubes by means of the film thickness measurement

    International Nuclear Information System (INIS)

    Malandrone, M.; Mioliggi, L.; Panella, B.; Scorta, G.

    1992-01-01

    The air-water countercurrent flow up to the flooding transition in a vertical tube has been experimentally investigated by liquid film thickness measurement performed by means of an electrical two-wires conductance probe. The liquid film mean thickness, the probability density function, the spectral power density and the power of the signal have been derived for a wide range of air and water flow rate, and related to the flow pattern with particular attention to the flooding phenomena. (6 figures) (Author)

  8. The determination of the pressure-viscosity coefficient of a lubricant through an accurate film thickness formula and accurate film thickness measurements : part 2 : high L values

    NARCIS (Netherlands)

    Leeuwen, van H.J.

    2011-01-01

    The pressure-viscosity coefficient of a traction fluid is determined by fitting calculation results on accurate film thickness measurements, obtained at different speeds, loads, and temperatures. Through experiments, covering a range of 5.6 thickness values are

  9. Visual outcomes of macular hole surgery

    International Nuclear Information System (INIS)

    Khaqan, H.A.; Muhammad, F.J.

    2016-01-01

    To determine the mean visual improvement after internal limiting membrane (ILM) peeling assisted with brilliant blue staining of ILM in macular hole, and stratify the mean visual improvement in different stages of macular hole. Study Design: Quasi-experimental study. Place and Duration of Study: Eye outpatient department (OPD), Lahore General Hospital, Lahore from October 2013 to December 2014. Methodology: Patients with macular hole underwent measurement of best corrected visual acuity (BCVA) and fundus examination with indirect slit lamp biomicroscopy before surgery. The diagnosis of all patients was confirmed on optical coherence tomography. All patients had 23G trans-conjunctival three ports pars plana vitrectomy, ILM peeling, and endotamponade of SF6. The mean visual improvement of different stages of macular hole was noted. Paired t-test was applied. Results: There were 30 patients, 15 males and 15 females (50%). The mean age was 62 ± 10.95 years. They presented with low mean preoperative visual acuity (VA) of 0.96 ± 0.11 logMar. The mean postoperative VA was 0.63 ± 0.24 logMar. The mean visual increase was 0.33 0.22 logMar (p < 0.001). In patients with stage 2 macular hole, mean visual increase was 0.35 ± 0.20 logMar (p < 0.001). In patients with stage 3 macular hole, mean visual increase was 0.44 ± 0.21 logMar (p < 0.001), and in patients with stage 4 macular hole it was 0.13 ± 0.1 logMar (p = 0.004). Conclusion: ILM peeling assisted with brilliant blue is a promising surgery for those patients who have decreased vision due to macular hole, in 2 - 4 stages of macular hole. (author)

  10. SEA ICE THICKNESS MEASUREMENT BY GROUND PENETRATING RADAR FOR GROUND TRUTH OF MICROWAVE REMOTE SENSING DATA

    Directory of Open Access Journals (Sweden)

    M. Matsumoto

    2018-04-01

    Full Text Available Observation of sea ice thickness is one of key issues to understand regional effect of global warming. One of approaches to monitor sea ice in large area is microwave remote sensing data analysis. However, ground truth must be necessary to discuss the effectivity of this kind of approach. The conventional method to acquire ground truth of ice thickness is drilling ice layer and directly measuring the thickness by a ruler. However, this method is destructive, time-consuming and limited spatial resolution. Although there are several methods to acquire ice thickness in non-destructive way, ground penetrating radar (GPR can be effective solution because it can discriminate snow-ice and ice-sea water interface. In this paper, we carried out GPR measurement in Lake Saroma for relatively large area (200 m by 300 m, approximately aiming to obtain grand truth for remote sensing data. GPR survey was conducted at 5 locations in the area. The direct measurement was also conducted simultaneously in order to calibrate GPR data for thickness estimation and to validate the result. Although GPR Bscan image obtained from 600MHz contains the reflection which may come from a structure under snow, the origin of the reflection is not obvious. Therefore, further analysis and interpretation of the GPR image, such as numerical simulation, additional signal processing and use of 200 MHz antenna, are required to move on thickness estimation.

  11. Sea Ice Thickness Measurement by Ground Penetrating Radar for Ground Truth of Microwave Remote Sensing Data

    Science.gov (United States)

    Matsumoto, M.; Yoshimura, M.; Naoki, K.; Cho, K.; Wakabayashi, H.

    2018-04-01

    Observation of sea ice thickness is one of key issues to understand regional effect of global warming. One of approaches to monitor sea ice in large area is microwave remote sensing data analysis. However, ground truth must be necessary to discuss the effectivity of this kind of approach. The conventional method to acquire ground truth of ice thickness is drilling ice layer and directly measuring the thickness by a ruler. However, this method is destructive, time-consuming and limited spatial resolution. Although there are several methods to acquire ice thickness in non-destructive way, ground penetrating radar (GPR) can be effective solution because it can discriminate snow-ice and ice-sea water interface. In this paper, we carried out GPR measurement in Lake Saroma for relatively large area (200 m by 300 m, approximately) aiming to obtain grand truth for remote sensing data. GPR survey was conducted at 5 locations in the area. The direct measurement was also conducted simultaneously in order to calibrate GPR data for thickness estimation and to validate the result. Although GPR Bscan image obtained from 600MHz contains the reflection which may come from a structure under snow, the origin of the reflection is not obvious. Therefore, further analysis and interpretation of the GPR image, such as numerical simulation, additional signal processing and use of 200 MHz antenna, are required to move on thickness estimation.

  12. Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea.

    Science.gov (United States)

    Clement, Colin I; Parker, Douglas G A; Goldberg, Ivan

    2016-01-01

    Accurate measurement of intra-ocular pressure is a fundamental component of the ocular examination. The most common method of measuring IOP is by Goldmann applanation tonometry, the accuracy of which is influenced by the thickness and biomechanical properties of the cornea. Algorithms devised to correct for corneal thickness to estimate IOP oversimplify the effects of corneal biomechanics. The viscous and elastic properties of the cornea influence IOP measurements in unpredictable ways, a finding borne out in studies of patients with inherently abnormal and surgically altered corneal biomechanics. Dynamic contour tonometry, rebound tonometry and the ocular response analyzer provide useful alternatives to GAT in patients with abnormal corneas, such as those who have undergone laser vision correction or keratoplasty. This article reviews the various methods of intra-ocular pressure measurement available to the clinician and the ways in which their utility is influenced by variations in corneal thickness and biomechanics.

  13. Thickness measurement by two-sided step-heating thermal imaging

    Science.gov (United States)

    Li, Xiaoli; Tao, Ning; Sun, J. G.; Zhang, Cunlin; Zhao, Yuejin

    2018-01-01

    Infrared thermal imaging is a promising nondestructive technique for thickness prediction. However, it is usually thought to be only appropriate for testing the thickness of thin objects or near-surface structures. In this study, we present a new two-sided step-heating thermal imaging method which employed a low-cost portable halogen lamp as the heating source and verified it with two stainless steel step wedges with thicknesses ranging from 5 mm to 24 mm. We first derived the one-dimensional step-heating thermography theory with the consideration of warm-up time of the lamp, and then applied the nonlinear regression method to fit the experimental data by the derived function to determine the thickness. After evaluating the reliability and accuracy of the experimental results, we concluded that this method is capable of testing thick objects. In addition, we provided the criterions for both the required data length and the applicable thickness range of the testing material. It is evident that this method will broaden the thermal imaging application for thickness measurement.

  14. Relationship between renal cortex and parenchyma thickness and renal function: study with CT measurement

    International Nuclear Information System (INIS)

    Xu Yufeng; Tang Guangjian; Jiang Xuexiang

    2006-01-01

    Objective: To study the relationship between renal morphology and renal function, and to assess the value of CT as a criterion to grade renal function. Methods: Enhancement CT were performed in 89 patients with no local renal disease whose split renal glomerular filtration rates (GFR) were measured by renal dynamic imaging with 99 Tc m -DTPA. The 178 kidneys were divided into normal renal function, mild and severe renal impairment groups according to renal function. Differences between three groups respect to the mean thickness of renal cortex and parenchyma were assessed by ANOVA. Using Pearson's correlation test, the correlation between the renal cortex, parenchyma thicknesses and renal GFR were examined. The value of CT in predicting renal function was assessed by using ROC analysis. Results: The renal cortex thicknesses of normal renal function, mild and severe renal impairment groups were (5.9±1.1), (4.6± 1.1), and (3.3±1.0) mm respectively, and the renal parenchyma thicknesses were (26.3±4.2), (21.3±4.6), (16.2±4.6) mm. There were significant differences of renal cortex, parenchyma thicknesses between 3 groups (cortex F=54.78, P<0.01; parenehyma F=43.90, P<0.01). The thicknesses of renal cortex (r=0.752, P<0.01), parenchyma (r=0.738, P<0.01) had positive linear correlation with renal function. ROC analysis of the renal cortex thicknesses measured by CT in predicting mild and severe renal impairment showed that the Az was 0.860 and 0.905 respectively, whereas that of parenchyma was 0.868 and 0.884. Conclusion: The thicknesses of renal cortex, parenchyma measured by CT can reflect renal function. CT was a supplementary method to assess renal function. (authors)

  15. Measurement of lateral charge diffusion in thick, fully depleted, back-illuminated CCDs

    Energy Technology Data Exchange (ETDEWEB)

    Karcher, Armin; Bebek, Christopher J.; Kolbe, William F.; Maurath, Dominic; Prasad, Valmiki; Uslenghi, Michela; Wagner, Martin

    2004-06-30

    Lateral charge diffusion in back-illuminated CCDs directly affects the point spread function (PSF) and spatial resolution of an imaging device. This can be of particular concern in thick, back-illuminated CCDs. We describe a technique of measuring this diffusion and present PSF measurements for an 800 x 1100, 15 mu m pixel, 280 mu m thick, back-illuminated, p-channel CCD that can be over-depleted. The PSF is measured over a wavelength range of 450 nm to 650 nm and at substrate bias voltages between 6 V and 80 V.

  16. A convenient method for X-ray analysis in TEM that measures mass thickness and composition

    Science.gov (United States)

    Statham, P.; Sagar, J.; Holland, J.; Pinard, P.; Lozano-Perez, S.

    2018-01-01

    We consider a new approach for quantitative analysis in transmission electron microscopy (TEM) that offers the same convenience as single-standard quantitative analysis in scanning electron microscopy (SEM). Instead of a bulk standard, a thin film with known mass thickness is used as a reference. The procedure involves recording an X-ray spectrum from the reference film for each session of acquisitions on real specimens. There is no need to measure the beam current; the current only needs to be stable for the duration of the session. A new reference standard with a large (1 mm x 1 mm) area of uniform thickness of 100 nm silicon nitride is used to reveal regions of X-ray detector occlusion that would give misleading results for any X-ray method that measures thickness. Unlike previous methods, the new X-ray method does not require an accurate beam current monitor but delivers equivalent accuracy in mass thickness measurement. Quantitative compositional results are also automatically corrected for specimen self-absorption. The new method is tested using a wedge specimen of Inconel 600 that is used to calibrate the high angle angular dark field (HAADF) signal to provide a thickness reference and results are compared with electron energy-loss spectrometry (EELS) measurements. For the new X-ray method, element composition results are consistent with the expected composition for the alloy and the mass thickness measurement is shown to provide an accurate alternative to EELS for thickness determination in TEM without the uncertainty associated with mean free path estimates.

  17. Manual B-mode versus automated radio-frequency carotid intima-media thickness measurements

    NARCIS (Netherlands)

    Dogan, Soner; Plantinga, Yvonne; Dijk, Joke M.; van der Graaf, Yolanda; Grobbee, Diederick E.; Bots, Michiel L.; Algra, N. N.; Doevendans, P. A.; Eikelboom, C.; van der Graaf, Y.; Grobbee, E.; Kappelle, L. J.; Mali, W. P. Th M.; Moll, F. L.; Rutten, G. E. H. M.; Visseren, F. L. J.

    2009-01-01

    Carotid intima-media thickness (CIMT) serves as an indicator of atherosclerosis and cardiovascular risk. Manual measurements of B-mode ultrasound images are the most applied method. Automated measurements with radiofrequency (RF) ultrasound have been suggested as an alternative. The aim of this

  18. CT measurement of normal pericardial thickness in adults on computed tomography

    International Nuclear Information System (INIS)

    Choi, Young Woo; Park, Chan Sup; Jeon, Yong Sun; Bae, In Young; Choi, Sung Gyu; Koo, Jin Hoe; Chung, Won Kyun

    1998-01-01

    The purpose of this study was to establish, using computed tomography, the normal thickness of the pericardium in adults. Materials and Methods: CT scans of 50 patients, including sections through the level of the heart, were reviewed. Patients were excluded if there were any suspicions of pericardial abnormality such as infectious or neoplastic diseases. Twenty-four of the 50 were men and 26 were women; their mean age was 47.0(range,18-76) years. We measured pericardial thickness at the level of the right ventricle, interventricular septum and left ventricle, and also compared pericardial thickness in terms of age and sex. Results: In all patients, the pericardium was observed in the right ventricular region; in 41 (82%) at the interventricular septum; and in 41 (82%) along the left ventricle. The mean thickness of normal pericardium at the level of the right ventricle, interventricular septum, and left ventricle was 1.8 mm ± 0.5 mm, 1.8 mm ± 0.4 mm, and 1.7 mm ± 0.5 mm, respectively. No statistically significant correlation was apparent between pericardial thickness and age group (p > 0.63, ANOVA test). Mean pericardial thickness was 1.9 mm ± 0.6 mm in males and 1.7 mm ± 0.4 mm in females; thus, no statistically significant correlation was apparent between pericardial thickness and sex (p >0.29, Student's t-test). Conclusion: The pericardium was best visualized in sections through the right ventricle.The mean thickness of normal pericardium was 1.8 mm ± 0.5 mm and pericardial thickness did not differ according to age or sex

  19. A new measurement method of coatings thickness based on lock-in thermography

    Science.gov (United States)

    Zhang, Jin-Yu; Meng, Xiang-bin; Ma, Yong-chao

    2016-05-01

    Coatings have been widely used in modern industry and it plays an important role. Coatings thickness is directly related to the performance of the functional coatings, therefore, rapid and accurate coatings thickness inspection has great significance. Existing coatings thickness measurement method is difficult to achieve fast and accurate on-site non-destructive coatings inspection due to cost, accuracy, destruction during inspection and other reasons. This paper starts from the introduction of the principle of lock-in thermography, and then performs an in-depth study on the application of lock-in thermography in coatings inspection through numerical modeling and analysis. The numerical analysis helps explore the relationship between coatings thickness and phase, and the relationship lays the foundation for accurate calculation of coatings thickness. The author sets up a lock-in thermography inspection system and uses thermal barrier coatings specimens to conduct an experiment. The specimen coatings thickness is measured and calibrated to verify the quantitative inspection. Experiment results show that the lock-in thermography method can perform fast coatings inspection and the inspection accuracy is about 95%. Therefore, the method can meet the field testing requirements for engineering projects.

  20. Measurement of sheath thickness by lining out grooves in the Hall-type stationary plasma thrusters

    International Nuclear Information System (INIS)

    Yu Daren; Wu Zhiwen; Ning Zhongxi; Wang Xiaogang

    2007-01-01

    Using grooves created along the axial direction of the discharge channel, a method for measuring sheath thickness in Hall-type stationary plasma thrusters has been developed. By distorting the wall surface using these grooves, it is possible to numerically study the effect of the wall surface on the sheath and near wall conductivity. Monte Carlo method is applied to calculate the electron temperature variation with different groove depths. The electron dynamic process in the plasma is described by a test particle method with the electron randomly entering the sheath from the discharge channel and being reflected back. Numerical results show that the reflected electron temperature is hardly affected by the wall surface if the groove depth is much less than the sheath thickness. On the other hand, the reflected electron temperature increases if the groove depth is much greater than the sheath thickness. The reflected electron temperature has a sharp jump when the depth of groove is on the order of the sheath thickness. The simulation is repeated with different sheath thicknesses and the results are the same. Therefore, a diagnosis mean of the sheath thickness can be developed based on the method. Also the simulation results are in accord with the experimental data. Besides, the measurement method may be applicable to other plasma device with similar orthogonal steady state electrical and magnetic fields

  1. Oxide thickness measurement technique for duplex-layer Zircaloy-4 cladding

    International Nuclear Information System (INIS)

    McClelland, R.G.; O'Leary, P.M.

    1992-01-01

    Siemens Nuclear Power Corporation (SNP) is investigating the use of duplex-layer Zircaloy-4 tubing to improve the waterside corrosion resistance of cladding for high-burnup pressurized water reactor (PWR) fuel designs. Standard SNP PWR cladding is typically 0.762-mm (0.030-in.)-thick Zircaloy-4. The SNP duplex cladding is nominally 0.660-mm (0.026-in.)-thick Zircalloy-4 with an ∼0.102-mm (0.004-in.) outer layer of another, more corrosion-resistant, zirconium-based alloy. It is common industry practice to monitor the in-reactor corrosion behavior of Zircaloy cladding by using an eddy-current 'lift-off' technique to measure the oxide thickness on the outer surface of the fuel cladding. The test program evaluated three different cladding samples, all with the same outer diameter and wall thickness: Zircaloy-4 and duplex clad types D2 and D4

  2. Quantitative analysis and metallic coating thickness measurements by X-ray fluorescence

    International Nuclear Information System (INIS)

    Negrea, Denis; Ducu, Catalin; Malinovschi, Viorel; Moga, Sorin; Boicea, Niculae

    2009-01-01

    Full text: This paperwork covers the use of X-ray fluorescence (XRF) for determining the concentration and the coating thickness on metallic samples. The analysis method presented here may also be applicable to other coatings, providing that the elemental nature of the coating and substrate are compatible with the technical aspects of XRF, such as the absorption coefficient of the system, primary radiation, fluorescent radiation and type of detection. For the coating thickness measurement it was used the substrate-line attenuation method and a computing algorithm was developed. Its advantage relies in the fact that no special calibration with standard samples having different layer thickness is needed. The samples used for evaluation were metallic pieces of iron with zinc-nickel coatings of different thickness obtained by electrochemical deposition. (authors)

  3. Quantitative analysis and metallic coating thickness measurements by X-ray fluorescence

    International Nuclear Information System (INIS)

    Negrea, Denis; Ducu, Catalin; Malinovschi, Viorel; Moga, Sorin; Boicea, Niculae

    2009-01-01

    This work deals with the use of X-ray fluorescence (XRF) for determining the concentration and the coating thickness on metallic samples. The analysis method presented here may also be applicable to other coatings, providing that the elemental nature of the coating and substrate are compatible with the technical aspects of XRF, such as the absorption coefficient of the system, primary radiation, fluorescent radiation and type of detection. For the coating thickness measurement it was used the substrate-line attenuation method and an algorithm was developed. Its advantage relies in the fact that no special calibration with standard samples having different layer thickness is needed. The samples used for evaluation were metallic pieces of iron with zinc-nickel coatings of different thickness obtained by electrochemical deposition. (authors)

  4. Measurement of Li target thickness in the EVEDA Li Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Kanemura, Takuji, E-mail: kanemura.takuji@jaea.go.jp [Japan Atomic Energy Agency, 4002 Narita, O-arai, Higashi-Ibaraki-gun, Ibaraki 311-1393 (Japan); Kondo, Hiroo; Furukawa, Tomohiro; Hirakawa, Yasushi [Japan Atomic Energy Agency, 4002 Narita, O-arai, Higashi-Ibaraki-gun, Ibaraki 311-1393 (Japan); Hoashi, Eiji; Yoshihashi, Sachiko; Horiike, Hiroshi [Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan); Wakai, Eiichi [Japan Atomic Energy Agency, 4002 Narita, O-arai, Higashi-Ibaraki-gun, Ibaraki 311-1393 (Japan)

    2015-10-15

    Highlights: • The objective is to validate stability of the IFMIF liquid Li target flowing at 15 m/s. • Design requirement of target thickness fluctuation is ±1 mm. • Mean and maximum wave amplitude are 0.26 and 1.46 mm, respectively. • Average thickness can be well predicted with developed analytical model. • Li target was adequately stable and satisfied design requirement. - Abstract: A high-speed (nominal: 15 m/s, range: 10–16 m/s) liquid lithium wall jet is planned to serve as the target for two 40 MeV and 125 mA deuteron beams in the International Fusion Materials Irradiation Facility (IFMIF). The design requirement of target thickness stability is 25 ± 1 mm under a vacuum of 10{sup −3} Pa. This paper presents the results of the target thickness measurement conducted in the EVEDA Li Test Loop under a wide range of conditions including the IFMIF condition (target speed of 10, 15, and 20 m/s; vacuum pressure of 10{sup −3} Pa; and Li temperature of 250 °C). For measurement, we use a laser probe method that we developed in advance; this method generates statistical measurements method using a laser distance meter. The measurement results obtained under the IFMIF nominal condition (15 m/s, 10{sup −3} Pa, 250 °C) at the IFMIF beam center are as follows: average target thickness = 26.08 ± 0.09 mm (2σ), mean wave amplitude = 0.26 ± 0.01 mm (2σ), and maximum wave amplitude = 1.46 ± 0.25 mm (2σ). Of the total wave components, 99.7% are within the design requirement. The analytically predicted target thickness is in excellent agreement with the experimental data, resulting in successful characterization of the Li target thickness.

  5. Sea-ice thickness from field measurements in the northwestern Barents Sea

    Science.gov (United States)

    King, Jennifer; Spreen, Gunnar; Gerland, Sebastian; Haas, Christian; Hendricks, Stefan; Kaleschke, Lars; Wang, Caixin

    2017-02-01

    The Barents Sea is one of the fastest changing regions of the Arctic, and has experienced the strongest decline in winter-time sea-ice area in the Arctic, at -23±4% decade-1. Sea-ice thickness in the Barents Sea is not well studied. We present two previously unpublished helicopter-borne electromagnetic (HEM) ice thickness measurements from the northwestern Barents Sea acquired in March 2003 and 2014. The HEM data are compared to ice thickness calculated from ice draft measured by ULS deployed between 1994 and 1996. These data show that ice thickness varies greatly from year to year; influenced by the thermodynamic and dynamic processes that govern local formation vs long-range advection. In a year with a large inflow of sea-ice from the Arctic Basin, the Barents Sea ice cover is dominated by thick multiyear ice; as was the case in 2003 and 1995. In a year with an ice cover that was mainly grown in situ, the ice will be thin and mechanically unstable; as was the case in 2014. The HEM data allow us to explore the spatial and temporal variability in ice thickness. In 2003 the dominant ice class was more than 2 years old; and modal sea-ice thickness varied regionally from 0.6 to 1.4 m, with the thinner ice being either first-year ice, or multiyear ice which had come into contact with warm Atlantic water. In 2014 the ice cover was predominantly locally grown ice less than 1 month old (regional modes of 0.5-0.8 m). These two situations represent two extremes of a range of possible ice thickness distributions that can present very different conditions for shipping traffic; or have a different impact on heat transport from ocean to atmosphere.

  6. Role of experimental resolution in measurements of critical layer thickness for strained-layer epitaxy

    International Nuclear Information System (INIS)

    Fritz, I.J.

    1987-01-01

    Experimental measurements of critical layer thicknesses (CLT's) in strained-layer epitaxy are considered. Finite experimental resolution can have a major effect on measured CLT's and can easily lead to spurious results. The theoretical approach to critical layer thicknesses of J. W. Matthews [J. Vac. Sci. Technol. 12, 126 (1975)] has been modified in a straightforward way to predict the apparent critical thickness for an experiment with finite resolution in lattice parameter. The theory has also been modified to account for the general empirical result that fewer misfit dislocations are generated than predicted by equilibrium calculation. The resulting expression is fit to recent x-ray diffraction data on InGaAs/GaAs and SiGe/Si. The results suggest that CLT's in these systems may not be significantly larger than predicted by equilibrium theory, in agreement with high-resolution measurements

  7. Tundish Cover Flux Thickness Measurement Method and Instrumentation Based on Computer Vision in Continuous Casting Tundish

    Directory of Open Access Journals (Sweden)

    Meng Lu

    2013-01-01

    Full Text Available Thickness of tundish cover flux (TCF plays an important role in continuous casting (CC steelmaking process. Traditional measurement method of TCF thickness is single/double wire methods, which have several problems such as personal security, easily affected by operators, and poor repeatability. To solve all these problems, in this paper, we specifically designed and built an instrumentation and presented a novel method to measure the TCF thickness. The instrumentation was composed of a measurement bar, a mechanical device, a high-definition industrial camera, a Siemens S7-200 programmable logic controller (PLC, and a computer. Our measurement method was based on the computer vision algorithms, including image denoising method, monocular range measurement method, scale invariant feature transform (SIFT, and image gray gradient detection method. Using the present instrumentation and method, images in the CC tundish can be collected by camera and transferred to computer to do imaging processing. Experiments showed that our instrumentation and method worked well at scene of steel plants, can accurately measure the thickness of TCF, and overcome the disadvantages of traditional measurement methods, or even replace the traditional ones.

  8. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Retrospective analyses of optical coherence tomography in recurrent macular edema following intravitreal therapy in patients with retinal vein occlusion.

    Science.gov (United States)

    Holland, Stephen M; Dodwell, David G; Krimmel, Darrel A; de Fiebre, Christopher M

    2015-09-04

    Optical coherence tomography has focused mainly on central subfield thickness to quantify macular edema in central and branch retinal vein occlusion. We examined macular fields other than the central subfield to determine if they are possibly independent indicators of recurrent macular edema. Single center, retrospective, consecutive case study of patients with recurrent macular edema secondary to either central or branch retinal vein occlusion. Thickness estimates of serial domain optical coherence tomography macular fields were obtained at the time of recurrent macular edema and analyzed retrospectively. Changes were expressed as a percentage of previous baseline levels. Change in thickness at each retreatment episode as well as average changes in thickness were calculated for each macular field for each eye. Data were analyzed via analysis of variance and Fisher's post hoc analyses. The macular field which most frequently had the largest percent increase at the time of recurrence was also assessed using averages for each subject as well as for each retreatment episode. Individual episodes of recurrent macular edema were also examined to ascertain the frequency in which there was minimal foveal edema (<15 μm increase), but non-foveal edema was considered severe enough to warrant retreatment. 429 episodes of recurrent macular edema in 80 eyes were examined. In addition to the central subfield, the average mean change in thickness of the most affected quadrant (central vein occlusion) or hemisphere (branch vein occlusion) of the extrafoveal 3 mm band had the largest mean changes and also most frequently had the largest increases at the time of recurrent macular edema. In approximately 20 % of both central and branch occlusions, recurrent macular edema was detected in non-central macular fields in the absence of significant edema in the central subfield. Analyses of non-central macular fields as well as the central subfield may be useful in the early detection

  10. Development of ultrasonic heat transfer tube thickness measurement apparatus. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Ohba, Toshihiro; Katoh, Chiaki; Yanagihara, Takao [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Suetugu, Hidehiko; Yano, Masaya [Sumitomo Chemical Co., Ltd., Tokyo (Japan)

    2003-01-01

    The demonstration test for evaluating reliability of the acid recovery evaporator at Rokkasho Reprocessing Plant has been carried out at JAERI. For the nondestructive measurement of the thickness of heat transfer tubes of the acid recovery evaporator in corrosion test, we have developed thickness measurement apparatus for heat transfer tubes by ultrasonic immersion method with high resolution. The ultrasonic prove in a heat transfer tube can be moved vertically and radially. The results obtained by this apparatus coincident well with those obtained by a destructive method using an optical microscope. (author)

  11. Simultaneous measurement of group refractive index and thickness of optical samples using optical coherence tomography

    International Nuclear Information System (INIS)

    Cheng, Hsu-Chih; Liu, Yi-Cheng

    2010-01-01

    Optical coherence tomography (OCT), based on a Michelson interferometer and utilizing low coherence light as the optical source, is a novel technique for the noninvasive imaging of optical scattering media. A simple OCT scheme based on a 3x3 fiber coupler is presented for the simultaneous measurement of the refractive index and thickness of optical samples. The proposed system enables the refractive index and thickness to be determined without any prior knowledge of the sample parameters and is characterized by a simple and compact configuration, a straightforward measurement procedure, and a low cost. The feasibility of the proposed approach is demonstrated experimentally using BK7 and B270 optical glass samples.

  12. Measurement of the thickness and homogeneity of thin foils by slowing down alpha particles

    International Nuclear Information System (INIS)

    Bimbot, R.; Della Negra, S.; Deprun, C.; Gardes, D.; Rivet, M.F.

    1979-01-01

    The energy loss of 8.785 MeV α particles passing through a thin foil is used to measure the foil thickness. The measurement is performed in various points of the target, the abscissa and ordinate of which are set with precision from the outside of the chamber. This gives a thickness map of the target. The working up of the data, and the use of energy loss tables are made in a standard way. The absolute uncertainty is of some percent for 100 μg/cm 2 foils. The technique has been refined to reach the same precision for 10 μg/cm 2 targets [fr

  13. Uncertainty in stratiform cloud optical thickness inferred from pyranometer measurements at the sea surface

    Directory of Open Access Journals (Sweden)

    Anna Rozwadowska

    2004-06-01

    Full Text Available The relative "plane-parallel" error in a mean cloud optical thickness retrieved from ground-based pyranometer measurements is estimated. The plane-parallel error is defined as the bias introduced by the assumption in the radiative transfer model used in cloud optical thickness retrievals that the atmosphere, including clouds, is horizontally homogeneous on the scale of an individual retrieval. The error is estimated for the optical thickness averaged over the whole domain, which simulates the mean cloud optical thickness obtained from a time series of irradiance measurements. The study is based on 3D Monte Carlo radiative transfer simulations for non-absorbing, all-liquid, layer clouds. Liquid water path distributions in the clouds are simulated by a bounded cascade fractal model. The sensitivity of the error is studied with respect to the following factors: averaging time of irradiance used in an individual retrieval, mean cloud optical thickness, cloud variability, cloud base height and solar zenith angle. In the simulations presented in this paper, the relative bias in the domain averaged cloud optical thickness retrieved from pyranometer measurements varies from +1% for optically thin clouds to nearly -20%. The highest absolute value of the relative bias is expected for thick and variable clouds with high bases (e.g. 1 km and retrievals based on long-term mean irradiances (averaging time of the order of several tens of minutes or hours. The bias can be diminished by using short-term irradiance averages, e.g. of one minute, and by limiting retrievals to low-level clouds.

  14. Abdominal Subcutaneous Fat Thickness Measured by Ultrasonography Correlates with Hyperlipidemia and Steatohepatitis in Obese Children.

    Science.gov (United States)

    Lee, Sung Hyun; Kim, Dongwan; Baek, Min Young; Tchah, Hann; Kim, Yeon Sun; Ryoo, Eell; Kim, Yun Mi

    2015-06-01

    The aim of this study is to evaluate the relationship between abdominal subcutaneous fat thickness measured by ultrasonography (US) and serum lipid profile and liver transaminases in obese children. One hundred and sixty-six children diagnosed with obesity from May 2001 to December 2013 were included in this study. Data on serum lipid profile and liver transaminases were collected from clinical records. Abdominal subcutaneous fat thickness and grade of hepatic steatosis were evaluated by US. Of the 166 children, 107 were diagnosed with hepatic steatosis by US, 46 with grade I, 56 with grade II, and five children with grade III. According to the grade of hepatic steasosis, the average values of midline abdominal subcutaneous fat thickness and right flank abdominal subcutaneous fat thickness measured 2.9±0.8 cm and 1.9±0.7 cm in the normal group, 3.3±0.8 cm and 2.0±0.7 cm in grade I, 3.8±0.8 cm and 2.3±0.8 cm in grade II, and 4.1±0.8 cm and 2.8±1.4 cm in grade III, respectively. Abdominal subcutaneous fat thickness correlated with grade of hepatic steatosis (pabdominal subcutaneous fat thickness correlated with concentration of serum lipids and liver transaminases in the age group of 12-14 years (pAbdominal subcutaneous fat thickness measured by US can be used as a reliable predictor of possible hyperlipidemia and steatohepatitis in children, especially during the adolescent stage.

  15. Retinal nerve fiber layer thickness in normals measured by spectral domain OCT.

    Science.gov (United States)

    Bendschneider, Delia; Tornow, Ralf P; Horn, Folkert K; Laemmer, Robert; Roessler, Christopher W; Juenemann, Anselm G; Kruse, Friedrich E; Mardin, Christian Y

    2010-09-01

    To determine normal values for peripapillary retinal nerve fiber layer thickness (RNFL) measured by spectral domain Optical Coherence Tomography (SOCT) in healthy white adults and to examine the relationship of RNFL with age, gender, and clinical variables. The peripapillary RNFL of 170 healthy patients (96 males and 74 females, age 20 to 78 y) was imaged with a high-resolution SOCT (Spectralis HRA+OCT, Heidelberg Engineering) in an observational cross-sectional study. RNFL thickness was measured around the optic nerve head using 16 automatically averaged, consecutive circular B-scans with 3.4-mm diameter. The automatically segmented RNFL thickness was divided into 32 segments (11.25 degrees each). One randomly selected eye per subject entered the study. Mean RNFL thickness in the study population was 97.2 ± 9.7 μm. Mean RNFL thickness was significantly negatively correlated with age (r = -0.214, P = 0.005), mean RNFL decrease per decade was 1.90 μm. As age dependency was different in different segments, age-correction of RNFL values was made for all segments separately. Age-adjusted RNFL thickness showed a significant correlation with axial length (r = -0.391, P = 0.001) and with refractive error (r = 0.396, P<0.001), but not with disc size (r = 0.124). Normal RNFL results with SOCT are comparable to those reported with time-domain OCT. In accordance with the literature on other devices, RNFL thickness measured with SOCT was significantly correlated with age and axial length. For creating a normative database of SOCT RNFL values have to be age adjusted.

  16. Calculated /alpha/-induced thick target neutron yields and spectra, with comparison to measured data

    International Nuclear Information System (INIS)

    Wilson, W.B.; Bozoian, M.; Perry, R.T.

    1988-01-01

    One component of the neutron source associated with the decay of actinide nuclides in many environments is due to the interaction of decay /alpha/ particles in (/alpha/,n) reactions on low Z nuclides. Measurements of (/alpha/,n) thick target neutron yields and associated neutron spectra have been made for only a few combinations of /alpha/ energy and target nuclide or mixtures of actinide and target nuclides. Calculations of thick target neutron yields and spectra with the SOURCES code require /alpha/-energy-dependent cross sections for (/alpha/,n) reactions, as well as branching fractions leading to the energetically possible levels of the product nuclides. A library of these data has been accumulated for target nuclides of Z /le/ 15 using that available from measurements and from recent GNASH code calculations. SOURCES, assuming neutrons to be emitted isotopically in the center-of-mass system, uses libraries of /alpha/ stopping cross sections, (/alpha/,n) reaction cross reactions, product nuclide level branching fractions, and actinide decay /alpha/ spectra to calculate thick target (/alpha/,n) yields and neutron spectra for homogeneous combinations of nuclides. The code also calculates the thick target yield and angle intergrated neutron spectrum produced by /alpha/-particle beams on targets of homogeneous mixtures of nuclides. Illustrative calculated results are given and comparisons are made with measured thick target yields and spectra. 50 refs., 1 fig., 2 tabs

  17. Correlation of visual acuity and central macular morphology in different types of diabetic macular edema

    Directory of Open Access Journals (Sweden)

    Qiu-Ju Wu

    2016-02-01

    Full Text Available AIM:To observe the correlation of visual acuity and central macular morphology in patients with different types of diabetic macular edema(DME. METHODS: Presented study was single-center, uncontrolled retrospective clinical study. Sixty-two patients(103 eyeswith DME were included. Best corrected visual acuity(BCVAwas evaluated using early treatment diabetic retinopathy study(ETDRSvision test chart. All patients were examined by non-contact tonometer, slit lamp, indirect ophthalmoscope, and fundus fluorescein angiography(FFA. Central subfield mean thickness(CSMTin the macular area of diameter 1mm was measured by optical coherence tomography(OCT.And in the same time the integrity of inner segments/ outer segments(IS/OSand external limiting membrane(ELMreflecting light strip of 350μm center horizontal scanning line was investigated by OCT. BCVA and CSMT in different types of DME patients were analyzed using Kruskal- Wallis test. BCVA and CSMT between the two-two groups in different types of DME patients were analyzed using Nemenyi test, and multiple regression analysis was used to analyze the relative factors of BCVA. RESULTS: In the 103 eyes, 47 eyes(45.6%were focal DME, 35 eyes(34.0%were diffuse DME, 6 eyes(5.8%were ischemic DME and 15 eyes(14.6%were proliferative DME. The difference of mean BCVA(H=69.167, PH=57.113, Pχ2=14.982,Pχ2=14.537,Pχ2=15.596,Pχ2=15.393,Pχ2=16.567,Pχ2=15.687,Pχ2=12.974、P=0.008; CSMT:χ2=13.999,Pr=-0.064,-0.207,-0.082 and -0.160, respectively, Pr=-0.885, -2.522, -1.504, and-0.595, respectively, P>0.05. CONCLUSION: There are statistically significant differences on macular morphology and vision function among different types of DME patients.

  18. Evaluation of the x-ray fluorescence method of precious metal plating thickness measurements. Technological spinoff report

    International Nuclear Information System (INIS)

    Carson, J.S.; Hearn, N.K.; Pettie, C.B.

    1975-09-01

    It is shown that gold and silver plating thickness measurements made using an x-ray spectrograph could be closely correlated with thicknesses measured from sectional samples. Good correlations were also shown for single overlays of gold over silver when each layer was less than 0.0003 inch thick

  19. What Is Macular Edema?

    Medline Plus

    Full Text Available ... an Ophthalmologist Answers Would a macular wrinkle cause black streaks in my vision? Oct 05, 2017 When will I be able to see after vitrectomy surgery for a macular hole? Jan 24, 2016 Can Prolensa drops help a ...

  20. The macular xanthophylls.

    Science.gov (United States)

    Ahmed, Shazia S; Lott, McGregor N; Marcus, Dennis M

    2005-01-01

    The macular pigments are predominantly composed of three carotenoids: lutein, zeaxanthin, and meso-zeaxanthin. These carotenoids are concentrated and distributed in a selective manner. The properties of these pigments are further explored along with their methods of uptake, stabilization, and storage. The dual nature of these pigments as filters and antioxidants are elaborated upon in relation to their protective effects upon the macula, specifically in age-related macular degeneration. Evidence suggests that increased levels of macular pigment are correlated with a decreased risk of age-related macular degeneration. Many have sought to exploit this therapeutic relation. Studies reveal that oral supplementation with lutein and zeaxanthin can increase the levels of macular pigments in the retina and plasma. The effects of such supplementation on actual ocular function have yet to be fully addressed. New and standardized methods of assessing macular pigment density are discussed and future areas of research to further our understanding of macular xanthophylls as they pertain to age-related macular degeneration are highlighted.

  1. A digital instrument for nondestructive measurements of coating thicknesses by beta backscattering

    Science.gov (United States)

    Farcasiu, D. M.; Apostolescu, T.; Bozdog, H.; Badescu, E.; Bohm, V.; Stanescu, S. P.; Jianu, A.; Bordeanu, C.; Cracium, M. V.

    1992-02-01

    The elements of nondestructive gauging of coatings applied on various metal bases are presented. The intensity of the backscattered beta radiations is related to the thickness of the coating. With a fixed measuring geometry and radioactive sources (147Pm, 204Tl, 90Sr+90Y) the intensity of the backscattered beta particles is dependent on the following parameters: coating thickness, atomic number of the coating material and of the base, the beta particle energy and the surface finish. It can be used for the measurement of a wide range of coating thicknesses provided that the difference between the coating and the support atomic numbers is at least 20%. Fields of application include electronics, electrotechnique and so on.

  2. A digital instrument for nondestructive measurements of coating thicknesses by beta backscattering

    International Nuclear Information System (INIS)

    Farcasiu, D.M.; Apostolescu, T.; Bozdog, H.; Badescu, E.; Bohm, V.; Stanescu, S.P.; Jianu, A.; Bordeanu, C.; Craciun, M.V.

    1992-01-01

    The elements of nondestructive gauging of coatings applied on various metal bases are presented. The intensity of the backscattered beta radiations is related to the thickness of the coating. With a fixed measuring geometry and radioactive sources ( 147 Pm, 204 Tl, 90 Sr+ 90 Y) the intensity of the backscattered beta particles is dependent on the following parameters: Coating thickness, atomic number of the coating material and of the base, the beta particle energy and the surface finish. It can be used for the measurement of a wide range of coating thicknesses provided that the difference between the coating and the support atomic numbers is at least 20%. Fields of application include electronics, electrotechnique and so on. (orig.)

  3. Receiver calibration and the nonlinearity parameter measurement of thick solid samples with diffraction and attenuation corrections.

    Science.gov (United States)

    Jeong, Hyunjo; Barnard, Daniel; Cho, Sungjong; Zhang, Shuzeng; Li, Xiongbing

    2017-11-01

    This paper presents analytical and experimental techniques for accurate determination of the nonlinearity parameter (β) in thick solid samples. When piezoelectric transducers are used for β measurements, the receiver calibration is required to determine the transfer function from which the absolute displacement can be calculated. The measured fundamental and second harmonic displacement amplitudes should be modified to account for beam diffraction and material absorption. All these issues are addressed in this study and the proposed technique is validated through the β measurements of thick solid samples. A simplified self-reciprocity calibration procedure for a broadband receiver is described. The diffraction and attenuation corrections for the fundamental and second harmonics are explicitly derived. Aluminum alloy samples in five different thicknesses (4, 6, 8, 10, 12cm) are prepared and β measurements are made using the finite amplitude, through-transmission method. The effects of diffraction and attenuation corrections on β measurements are systematically investigated. When diffraction and attenuation corrections are all properly made, the variation of β between different thickness samples is found to be less than 3.2%. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Detrital illite crystals identified from crystallite thickness measurements in siliciclastic sediments

    Science.gov (United States)

    Aldega, L.; Eberl, D.D.

    2005-01-01

    Illite crystals in siliciclastic sediments are heterogeneous assemblages of detrital material coming from various source rocks and, at paleotemperatures >70 ??C, of superimposed diagenetic modification in the parent sediment. We distinguished the relative proportions of 2M1 detrital illite and possible diagenetic 1Md + 1M illite by a combined analysis of crystal-size distribution and illite polytype quantification. We found that the proportions of 1Md + 1M and 2M1 illite could be determined from crystallite thickness measurements (BWA method, using the MudMaster program) by unmixing measured crystallite thickness distributions using theoretical and calculated log-normal and/or asymptotic distributions. The end-member components that we used to unmix the measured distributions were three asymptotic-shaped distributions (assumed to be the diagenetic component of the mixture, the 1Md + 1M polytypes) calculated using the Galoper program (Phase A was simulated using 500 crystals per cycle of nucleation and growth, Phase B = 333/cycle, and Phase C = 250/ cycle), and one theoretical log-normal distribution (Phase D, assumed to approximate the detrital 2M1 component of the mixture). In addition, quantitative polytype analysis was carried out using the RockJock software for comparison. The two techniques gave comparable results (r2 = 0.93), which indicates that the unmixing method permits one to calculate the proportion of illite polytypes and, therefore, the proportion of 2M1 detrital illite, from crystallite thickness measurements. The overall illite crystallite thicknesses in the samples were found to be a function of the relative proportions of thick 2M1 and thin 1Md + 1M illite. The percentage of illite layers in I-S mixed layers correlates with the mean crystallite thickness of the 1Md + 1M polytypes, indicating that these polytypes, rather than the 2M1 polytype, participate in I-S mixed layering.

  5. Dexamethasone Intravitreal Implant for Diabetic Macular Edema During Pregnancy

    DEFF Research Database (Denmark)

    Concillado, Michael; Lund-Andersen, Henrik; Mathiesen, Elisabeth R

    2016-01-01

    PURPOSE: To describe the management of diabetic macular edema during pregnancy with the use of a dexamethasone slow-release intravitreal implant. DESIGN: Retrospective, observational, consecutive case series. METHODS: The study included 5 pregnant women who presented with diabetic macular edema...... injection. RESULTS: Diabetic macular edema involving the foveal center was observed between gestational weeks 9 and 23 in 10 eyes of 5 patients. Dexamethasone intravitreal implant injection was given 10 times in 9 eyes with a mean preinjection center field retinal thickness of 535 μm (range, 239-727 μm...... center field thickness and in 6 of 8 eyes by an increase in BCVA of 5 or more approxETDRS letters. A mild transient rise in intraocular pressure occurred in 3 out of 8 eyes. CONCLUSION: Diabetic macular edema involving the foveal center that presented during pregnancy responded promptly to intravitreal...

  6. Americium-241 use of measurement lead equivalent thickness for medical x-ray room: A review

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Saleh; Abd Aziz Mhd Ramli; Muhammad Jamal Md Isa; Mohd Firdaus Abd Rahman; Zainal Jamaluddin

    2010-01-01

    Lead equivalent thickness measurement of a shielding material in diagnostic radiology is very important to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. The Malaysian Ministry of Health (MOH) has established that the irradiation room must have sufficient shielding thickness, for example for general radiography it must be at least equal to 2.0 mm of Pb, for panoramic dental radiography at least equal to 1.5 mm of Pb and for mammography should be a minimum of 1.0 mm of Pb. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for X-ray room at health centres. Results of measurement of 30 irradiation rooms conducted from 2009 to mid 2010 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that 96.7 % of the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  7. Comparing electron tomography and HRTEM slicing methods as tools to measure the thickness of nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Alloyeau, D., E-mail: alloyeau.damien@gmail.com [Laboratoire Materiaux et Phenomenes Quantiques, Universite Paris 7/CNRS, UMR 7162, 2 Place Jussieu, 75251 Paris (France); Laboratoire d' Etude des Microstructures - ONERA/CNRS, UMR 104, B.P. 72, 92322 Chatillon (France); Ricolleau, C. [Laboratoire Materiaux et Phenomenes Quantiques, Universite Paris 7/CNRS, UMR 7162, 2 Place Jussieu, 75251 Paris (France); Oikawa, T. [Laboratoire Materiaux et Phenomenes Quantiques, Universite Paris 7/CNRS, UMR 7162, 2 Place Jussieu, 75251 Paris (France); JEOL (Europe) SAS, Espace Claude Monet, 1 Allee de Giverny, 78290 Croissy-sur-Seine (France); Langlois, C. [Laboratoire Materiaux et Phenomenes Quantiques, Universite Paris 7/CNRS, UMR 7162, 2 Place Jussieu, 75251 Paris (France); Le Bouar, Y.; Loiseau, A. [Laboratoire d' Etude des Microstructures - ONERA/CNRS, UMR 104, B.P. 72, 92322 Chatillon (France)

    2009-06-15

    Nanoparticles' morphology is a key parameter in the understanding of their thermodynamical, optical, magnetic and catalytic properties. In general, nanoparticles, observed in transmission electron microscopy (TEM), are viewed in projection so that the determination of their thickness (along the projection direction) with respect to their projected lateral size is highly questionable. To date, the widely used methods to measure nanoparticles thickness in a transmission electron microscope are to use cross-section images or focal series in high-resolution transmission electron microscopy imaging (HRTEM 'slicing'). In this paper, we compare the focal series method with the electron tomography method to show that both techniques yield similar particle thickness in a range of size from 1 to 5 nm, but the electron tomography method provides better statistics since more particles can be analyzed at one time. For this purpose, we have compared, on the same samples, the nanoparticles thickness measurements obtained from focal series with the ones determined from cross-section profiles of tomograms (tomogram slicing) perpendicular to the plane of the substrate supporting the nanoparticles. The methodology is finally applied to the comparison of CoPt nanoparticles annealed ex situ at two different temperatures to illustrate the accuracy of the techniques in detecting small particle thickness changes.

  8. Repeatability of central corneal thickness measurement with the Pentacam HR system

    Directory of Open Access Journals (Sweden)

    Ruiz Simonato Alonso

    2012-02-01

    Full Text Available PURPOSE: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT given by the Pentacam High Resolution (HR Comprehensive Eye Scanner (Oculus, Wetzlar, Germany over time. METHODS: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm 3 to 12 months apart, and compared. RESULTS: One hundred and sixteen eyes (n=116 of 62 health patients were included in this study. Average CCT in first and last visits was 541.6±37 µm and 543.6±36.9 µm respectively. Mean difference between both measurements was 9.2±6.4 µm, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r² = 0,9209. CONCLUSION: Pentacam (HR CTm gives repeatable CCT measurements over time.

  9. Performance of a fiber optic sensor for online measurement of coating thickness

    Science.gov (United States)

    D'Emilia, Giulio

    1999-01-01

    Some aspects concerning a methodology for the measurement of thickness of dry and wet coatings which is based on a fiber optic probe are discussed in order to verify the feasibility of this approach and the capability of such a probe of on- line measuring. In this preliminary step of the research some problems discussed mainly concerning the methodology which has been proposed and which is based on the measuring of the reflectance of the coating plated on thin steel sheets for use in the food industry. Furthermore the effect of the main interfering and modifying quantities is discussed both theoretically and experimentally when the measurement has to be carried out in order to allow on-line coating thickness measurements with satisfactory accuracy.

  10. Prevention of cystoid macular edema after lens extraction by topical indomethacin; Pt. 3. Radioimmunoassay measurement of Prostaglandins in the aqueous during and after lens extraction procedures

    Energy Technology Data Exchange (ETDEWEB)

    Miyake, K [Miyake Eye Clinic Hospital, Nagoya (Japan); Sugiyama, S; Norimatsu, I; Ozawa, T [Nagoya Univ. (Japan). Dept. of Biomedical Chemistry

    1978-01-01

    The amounts of prostaglandin (PG) E and Fsub(2..cap alpha..) in the aqueous humor were measured by radioimmuniassay techniques before and immediately after intracapsular and extracapsular cataract extractions. We found that: 1. the levels of PG E and PG Fsub(2..cap alpha..) are elevated by cataract extraction. 2. The elevated levels of PGs can all be prevented by preoperative application of topical indomethacin. 3. No differences in the amounts of PGs biosynthesized during intracapsular and extracapsular lens extraction were found. 4. In some cases, the levels of PG E were still elevated one week after surgery. These findings were used as the basis for our attempts to define the causes of cystoid macular edema (CME) following lens extractions.

  11. Triceps skin fold thickness as a measure of body fat in Nigerian ...

    African Journals Online (AJOL)

    Background: Skin fold thickness (SFT) at selected areas offers a simple method of subcutaneous fat assessment and provides a good estimate of obesity and body fat distribution. The triceps SFT has been shown to be one of the best and most popular sites for SFT measurement in children. Objective: To assess the body fat ...

  12. An optical method for measuring the thickness of a falling condensate in gravity assisted heat pipe

    Directory of Open Access Journals (Sweden)

    Kasanický Martin

    2015-01-01

    Full Text Available A large number of variables is the main problem of designing systems which uses heat pipes, whether it is a traditional - gravity, or advanced - capillary, pulsating, advanced heat pipes. This article is a methodology for measuring the thickness of the falling condensate in gravitational heat pipes, with using the optical triangulation method, and the evaluation of risks associated with this method.

  13. Correction of thickness measurement errors for two adjacent sheet structures in MR images

    International Nuclear Information System (INIS)

    Cheng Yuanzhi; Wang Shuguo; Sato, Yoshinobu; Nishii, Takashi; Tamura, Shinichi

    2007-01-01

    We present a new method for measuring the thickness of two adjacent sheet structures in MR images. In the hip joint, in which the femoral and acetabular cartilages are adjacent to each other, a conventional measurement technique based on the second derivative zero crossings (called the zero-crossings method) can introduce large underestimation errors in measurements of cartilage thickness. In this study, we have developed a model-based approach for accurate thickness measurement. We model the imaging process for two adjacent sheet structures, which simulate the two articular cartilages in the hip joint. This model can be used to predict the shape of the intensity profile along the sheet normal orientation. Using an optimization technique, the model parameters are adjusted to minimize the differences between the predicted intensity profile and the actual intensity profiles observed in the MR data. The set of model parameters that minimize the difference between the model and the MR data yield the thickness estimation. Using three phantoms and one normal cadaveric specimen, the usefulness of the new model-based method is demonstrated by comparing the model-based results with the results generated using the zero-crossings method. (author)

  14. Thin-film thickness measurement using x-ray peak ratioing in the scanning electron microscope

    International Nuclear Information System (INIS)

    Elliott, N.E.; Anderson, W.E.; Archuleta, T.A.; Stupin, D.M.

    1981-01-01

    The procedure used to measure laser target film thickness using a scanning electron microscope is summarized. This method is generally applicable to any coating on any substrate as long as the electron energy is sufficient to penetrate the coating and the substrate produces an x-ray signal which can pass back through the coating and be detected

  15. Aluminum hydroxide coating thickness measurements and brushing tests on K West Basin fuel elements

    International Nuclear Information System (INIS)

    Pitner, A.L.

    1998-01-01

    Aluminum hydroxide coating thicknesses were measured on fuel elements stored in aluminum canisters in K West Basin using specially developed eddy current probes . The results were used to estimate coating inventories for MCO fuel,loading. Brushing tests successfully demonstrated the ability to remove the coating if deemed necessary prior to MCO loading

  16. Radiographic technique and brackets affect measurements of proximal enamel thickness on mandibular incisors

    NARCIS (Netherlands)

    Ang, Amy Giok Phing; Steegmans, Pauline Antoinette Josephine; Kerdijk, Wouter; Livas, Christos; Ren, Yijin

    2017-01-01

    Objective: To investigate the influence of radiographic film and tube positioning, the presence and the size of brackets on in vitro measurements of proximal enamel thickness of mandibular incisors on periapical radiographs aimed to aid planning of interproximal enamel reduction procedures in

  17. Femoral cartilage thickness measurements in healthy individuals: learning, practicing and publishing with TURK-MUSCULUS.

    Science.gov (United States)

    Özçakar, Levent; Tunç, Hakan; Öken, Öznur; Ünlü, Zeliha; Durmuş, Bekir; Baysal, Özlem; Altay, Zuhal; Tok, Fatih; Akkaya, Nuray; Doğu, Beril; Çapkın, Erhan; Bardak, Ayşenur; Çarlı, Alparslan Bayram; Buğdaycı, Derya; Toktaş, Hasan; Dıraçoğlu, Demirhan; Gündüz, Berrin; Erhan, Belgin; Kocabaş, Hilal; Erden, Gül; Günendi, Zafer; Kesikburun, Serdar; Omaç, Özlem Köroğlu; Taşkaynatan, Mehmet Ali; Şenel, Kazım; Uğur, Mahir; Yalçınkaya, Ebru Yılmaz; Öneş, Kadriye; Atan, Çiğdem; Akgün, Kenan; Bilgici, Ayhan; Kuru, Ömer; Özgöçmen, Salih

    2014-01-01

    Measurement of the femoral cartilage thickness by using in-vivo musculoskeletal ultrasonography (MSUS) has been previously shown to be a valid and reliable method in previous studies; however, to our best notice, normative data has not been provided before in the healthy population.The aim of our study was to provide normative data regarding femoral cartilage thicknesses of healthy individuals with collaborative use of MSUS. This is across-sectional study run at Physical and Rehabilitation Medicine Departments of 18 Secondary and Tertiary Centers in Turkey. 1544 healthy volunteers (aged between 25-40 years) were recruited within the collaboration of TURK-MUSCULUS (Turkish Musculoskeletal Ultrasonography Study Group). Subjects who had a body mass index value of less than 30 and who did not have signs and symptoms of any degenerative/inflammatory arthritis or other rheumatic diseases, history of knee trauma and previous knee surgery were enrolled. Ultrasonographic measurements were performed axially from the suprapatellar window by using linear probes while subjects' knees were in maximum flexion. Three (mid-point) measurements were taken from both knees (lateral condyle, intercondylar area, medial condyle). A total of 2876 knees (of 817 M, 621 F subjects) were taken into analysis after exclusion of inappropriate images. Mean cartilage thicknesses were significantly lower in females than males (all p< 0.001). Thickness values negatively correlated with age; negatively (females) and positively (males) correlated with smoking. Men who regularly exercised had thicker cartilage than who did not exercise (all p < 0.05). Increased age (in both sexes) and absence of exercise (males) were found to be risk factors for decreased cartilage thicknesses. Further data pertaining to other countries would be interesting to uncover whether ethnic differences also affect cartilage thickness. Collaborative use of MSUS seems to be promising in this regard.

  18. Validation of Airborne FMCW Radar Measurements of Snow Thickness Over Sea Ice in Antarctica

    Science.gov (United States)

    Galin, Natalia; Worby, Anthony; Markus, Thorsten; Leuschen, Carl; Gogineni, Prasad

    2012-01-01

    Antarctic sea ice and its snow cover are integral components of the global climate system, yet many aspects of their vertical dimensions are poorly understood, making their representation in global climate models poor. Remote sensing is the key to monitoring the dynamic nature of sea ice and its snow cover. Reliable and accurate snow thickness data are currently a highly sought after data product. Remotely sensed snow thickness measurements can provide an indication of precipitation levels, predicted to increase with effects of climate change in the polar regions. Airborne techniques provide a means for regional-scale estimation of snow depth and distribution. Accurate regional-scale snow thickness data will also facilitate an increase in the accuracy of sea ice thickness retrieval from satellite altimeter freeboard estimates. The airborne data sets are easier to validate with in situ measurements and are better suited to validating satellite algorithms when compared with in situ techniques. This is primarily due to two factors: better chance of getting coincident in situ and airborne data sets and the tractability of comparison between an in situ data set and the airborne data set averaged over the footprint of the antennas. A 28-GHz frequency modulated continuous wave (FMCW) radar loaned by the Center for Remote Sensing of Ice Sheets to the Australian Antarctic Division is used to measure snow thickness over sea ice in East Antarctica. Provided with the radar design parameters, the expected performance parameters of the radar are summarized. The necessary conditions for unambiguous identification of the airsnow and snowice layers for the radar are presented. Roughnesses of the snow and ice surfaces are found to be dominant determinants in the effectiveness of layer identification for this radar. Finally, this paper presents the first in situ validated snow thickness estimates over sea ice in Antarctica derived from an FMCW radar on a helicopterborne platform.

  19. EVALUATION OF DIABETIC MACULAR OEDEMA WITH SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY AND FUNDUS FLUORESCEIN ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Mallika Venkitasubramanian

    2017-02-01

    Full Text Available BACKGROUND Macular oedema is an important cause of visual morbidity in Diabetic Retinopathy. It can be assessed by both Fundus Fluorescein Angiography (FFA and Optical Coherence Tomography (OCT. The aims of this study were to evaluate the agreement between morphological features on spectral domain Optical Coherence Tomography and Fluorescein Angiographic leakage patterns in Diabetic Macular Oedema, and to study the correlation between the best corrected visual acuity and central foveal thickness measured by Optical Coherence Tomography. MATERIALS AND METHODS This was an observational study. All patients with Diabetic Macular Oedema underwent complete ophthalmic examination and subjected to FFA and OCT. Presence or absence of macular oedema by FFA and OCT was noted and agreement between two modalities of imaging was assessed. Sensitivity of these modalities were also found out using appropriate statistical methods. Best Corrected Visual Acuity (BCVA measured were converted to LogMAR scale and Central foveal thickness measured by OCT. Linear regression analysis was done with central foveal thickness and LogMAR visual acuity. RESULTS A total of 69 eyes of 39 patients were studied. OCT revealed Diabetic Macular Oedema in 97.5% of eyes. Fundus Fluorescein Angiography performed in these patients identified leakage in 95.6% of eyes. Sensitivity and specificity of FFA and OCT were calculated keeping one as the gold standard for sensitivity and specificity of the other. FFA and OCT had almost equal sensitivity (95.46 for OCT and 96.92 for FFA for detection of DME. Specificity of OCT was found to be slightly higher (33.33% compared to FFA (25%. Our results suggest that there is minimal agreement between these two imaging modalities in evaluating DME. Statistically, Kappa value was 0.248. Linear regression analysis showed that central foveal thickness had a significant correlation with visual acuity, with Pearson correlation coefficient r=0.442, p=0

  20. Thin film thickness measurement error reduction by wavelength selection in spectrophotometry

    International Nuclear Information System (INIS)

    Tsepulin, Vladimir G; Perchik, Alexey V; Tolstoguzov, Victor L; Karasik, Valeriy E

    2015-01-01

    Fast and accurate volumetric profilometry of thin film structures is an important problem in the electronic visual display industry. We propose to use spectrophotometry with a limited number of working wavelengths to achieve high-speed control and an approach to selecting the optimal working wavelengths to reduce the thickness measurement error. A simple expression for error estimation is presented and tested using a Monte Carlo simulation. The experimental setup is designed to confirm the stability of film thickness determination using a limited number of wavelengths

  1. Measurement of neutron yield by 62 MeV proton beam on a thick Beryllium target

    International Nuclear Information System (INIS)

    Alba, R; Cosentino, G; Zoppo, A Del; Pietro, A Di; Figuera, P; Finocchiaro, P; Maiolino, C; Santonocito, D; Schillaci, M; Barbagallo, M; Colonna, N; Boccaccio, P; Esposito, J; Celentano, A; Osipenko, M; Ricco, G; Ripani, M; Viberti, C M; Kostyukov, A

    2013-01-01

    In the framework of research on IVth generation reactors and high intensity neutron sources a low-power prototype neutron amplifier was recently proposed by INFN. It is based on a low-energy, high current proton cyclotron, whose beam, impinging on a thick Beryllium converter, produces a fast neutron spectrum. The world database on the neutron yield from thick Beryllium target in the 70 MeV proton energy domain is rather scarce. The new measurement was performed at LNS, covering a wide angular range from 0 to 150 degrees and an almost complete neutron energy interval. In this contribution the preliminary data are discussed together with the proposed ADS facility.

  2. Value of endometrial thickness measurement for diagnosing focal intrauterine pathology in women without abnormal uterine bleeding

    DEFF Research Database (Denmark)

    Dreisler, E; Sorensen, S Stampe; Ibsen, P H

    2009-01-01

    OBJECTIVE: To assess the diagnostic value of transvaginal sonographic (TVS) measurement of endometrial thickness for diagnosing focal intrauterine pathology in women without abnormal uterine bleeding (AUB). METHODS: A random selection from the Danish Civil Registration System was made: 1660 women...... of endometrial thickness is a poor diagnostic test, but is apparently efficacious in excluding focal intrauterine pathology, especially in postmenopausal women. The 4-5-mm threshold conventionally used to exclude endometrial malignancy in women with postmenopausal bleeding is not transferable to women without...

  3. Role of Measurement of the Maximum Intimal-Medial Thickness in the Brain Health Examination Program

    OpenAIRE

    上山, 憲司; 中川原, 譲二; 武田, 利兵衛; 中村, 博彦

    2005-01-01

    The maximum intimal-medial thickness (Max-IMT) of the carotid artery wall (Max-IMT) was measured by ultrasonography in 1,932 people checked in the brain health examination program in our hospital. We studied relationship Max-IMT and age, systolic blood pressure, presence of asymptomatic cerebral infarction. Five hundreds seventy-two people (29.9%) had atherosclerotic thickness of Max-IMT that was more than 1.1 mm. Normal Max-IMT that less than 1.0 mm was observed in 1,360 people (70.1%). More...

  4. Measurement of oxide-layer thickness of internal granules in high-purity aluminium

    International Nuclear Information System (INIS)

    Takacs, S.; Ditroi, F.; Mahunka, I.

    1989-01-01

    Charged-particle activation analysis was used for the determination of bulk oxygen concentration in aluminium. High-purity aluminium samples and mixtures containing different amounts of alumina were irradiated by 13 MeV 3 He particles. The aim of the investigation was to determine the oxide-layer thickness on the surface of internal aluminium granules. The measurement was carried out by determining the bulk oxygen concentration in the samples, and calculating the oxide-layer thickness, by using model conditions about the microstructure of the aluminium samples. (author) 5 refs

  5. XRD measurement of mean thickness, thickness distribution and strain for illite and illite-smectite crystallites by the Bertaut-Warren-Averbach technique

    Science.gov (United States)

    Drits, Victor A.; Eberl, Dennis D.; Środoń, Jan

    1998-01-01

    A modified version of the Bertaut-Warren-Averbach (BWA) technique (Bertaut 1949, 1950; Warren and Averbach 1950) has been developed to measure coherent scattering domain (CSD) sizes and strains in minerals by analysis of X-ray diffraction (XRD) data. This method is used to measure CSD thickness distributions for calculated and experimental XRD patterns of illites and illite-smectites (I-S). The method almost exactly recovers CSD thickness distributions for calculated illite XRD patterns. Natural I-S samples contain swelling layers that lead to nonperiodic structures in the c* direction and to XRD peaks that are broadened and made asymmetric by mixed layering. Therefore, these peaks cannot be analyzed by the BWA method. These difficulties are overcome by K-saturation and heating prior to X-ray analysis in order to form 10-Å periodic structures. BWA analysis yields the thickness distribution of mixed-layer crystals (coherently diffracting stacks of fundamental illite particles). For most I-S samples, CSD thickness distributions can be approximated by lognormal functions. Mixed-layer crystal mean thickness and expandability then can be used to calculate fundamental illite particle mean thickness. Analyses of the dehydrated, K-saturated samples indicate that basal XRD reflections are broadened by symmetrical strain that may be related to local variations in smectite interlayers caused by dehydration, and that the standard deviation of the strain increases regularly with expandability. The 001 and 002 reflections are affected only slightly by this strain and therefore are suited for CSD thickness analysis. Mean mixed-layer crystal thicknesses for dehydrated I-S measured by the BWA method are very close to those measured by an integral peak width method.

  6. Combination of Anti-VEGF and Laser Photocoagulation for Diabetic Macular Edema: A Review

    Directory of Open Access Journals (Sweden)

    Laura N. Distefano

    2017-01-01

    Full Text Available Diabetic macular edema (DME is the most common cause of vision loss in diabetic patients. Thirty years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS demonstrated that focal/grid laser photocoagulation reduces moderate vision loss from DME by 50% or more; thus, macular photocoagulation became the gold standard treatment for DME. However, with the development of anti-VEGF drugs (bevacizumab, ranibizumab, and aflibercept, better outcomes were obtained in terms of visual acuity gain and decrease in macular thickness in some studies when antiangiogenic drugs were administered in monotherapy. Macular laser therapy may still play an important role as an adjuvant treatment because it is able to improve macular thickness outcomes and reduce the number of injections needed. Here, we review some of the clinical trials that have assessed the efficacy of macular laser treatment, either as part of the treatment protocol or as rescue therapy.

  7. On the comparison between MRI and US imaging for human heel pad thickness measurements

    DEFF Research Database (Denmark)

    Matteoli, Sara; Corbin, Nadège Corbin; Wilhjelm, Jens E.

    2011-01-01

    The human heel pad thickness, defined as the shortest distance between the calcaneus and heel skin, is one of the intrinsic factor which must be taken into account when investigating the biomechanics of the heel pad. US and MRI are the preferable imaging modalities used to measure the heel pad...... thickness as they are both ionizing-free radiations. The aim of this paper is to measure the bone to skin distance of nine heel pad phantoms from MRI and US images, and to compare the results with a true value (TV) in order to find the errors. Paired sample t-test was used to compare the measurements......1530 (P-value=0.402). Results confirm the necessity to investigate on the real speed of sound for the heel pad tissues, in order to have realistic measurements when dealing with human heel pads. __________________________________________________________________________________________________________...

  8. Articular Cartilage Thickness Measured with US is Not as Easy as It Appears

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Bartels, E. M.; Wilhjelm, Jens E.

    2011-01-01

    insonation. If US measurements are compared to measurements with other techniques, they should be corrected for the higher sound speed in cartilage. Purpose: To study whether investigators correctly identify the articular cartilage, whether they insonate orthogonally, and whether they correct for sound speed....... Materials and Methods: A literature search limited to the last 10 years of studies applying US to measure cartilage thickness. Results: 15 studies were identified and they referred to another 8 studies describing methods of thickness measurement. 11 of the 15 studies identified the superficial cartilage...... border incorrectly, and 6 applied oblique insonation. 2 of the 15 studies corrected for sound speed. Of the further 8 studies, one might correctly identify the superficial cartilage border, 4 applied oblique insonation, and none corrected for sound speed. Conclusion: We found that the majority of studies...

  9. An examination of mass thickness measurements with X-ray sources

    International Nuclear Information System (INIS)

    Chen Mincong; Li Hongmei; Chen Ziyu; Shen Ji

    2008-01-01

    A method using X-rays to measure mass thickness is discussed. The method utilizes a filter to absorb low energy and characteristic photons so that the hardened X-ray spectra have a peaked energy distribution. An equivalent X-ray energy, which defines the attenuation in a material of interest can be used. The effect on the X-ray spectra of different filters is examined with Monte Carlo simulation using the EGSnrc package. A theoretical model for X-ray absorption that shows that the method can achieve good precision for a certain range of mass thicknesses is advanced. Experimental results agree well with the theoretical analysis. It is found that for a certain range of mass thicknesses, the relative error can be less than 1% for the aluminum alloy sample at the tube voltage of 30 or 45 kV

  10. An examination of mass thickness measurements with X-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    Chen Mincong; Li Hongmei; Chen Ziyu [Department of Modern Physics, University of Science and Technology of China, Jin Zhai Road, Hefei 230026 (China); Shen Ji [Department of Modern Physics, University of Science and Technology of China, Jin Zhai Road, Hefei 230026 (China)], E-mail: shenji@ustc.edu.cn

    2008-10-15

    A method using X-rays to measure mass thickness is discussed. The method utilizes a filter to absorb low energy and characteristic photons so that the hardened X-ray spectra have a peaked energy distribution. An equivalent X-ray energy, which defines the attenuation in a material of interest can be used. The effect on the X-ray spectra of different filters is examined with Monte Carlo simulation using the EGSnrc package. A theoretical model for X-ray absorption that shows that the method can achieve good precision for a certain range of mass thicknesses is advanced. Experimental results agree well with the theoretical analysis. It is found that for a certain range of mass thicknesses, the relative error can be less than 1% for the aluminum alloy sample at the tube voltage of 30 or 45 kV.

  11. Utilization of the Rutherford backscattering technique for precise measurements of thickness by an alternative procedure

    International Nuclear Information System (INIS)

    Chagas, E.F.

    1985-01-01

    This technique was used to determine the thickness of targets on very thick substrates as this type of target is used a lot in nuclear physics, and especially in γ spectroscpy. The difficulties introduced in this case, occur because of the appearance of a small peak on a very high continuous background, due to the fact that the atomic number of the substrate is bigger than that of the targets. These difficulties are overcome using an alternative procedure to determine precisely the loss of energy of the beam whilst crossing the refered target. Targets of 59 Co, 46-48-50 Ti and 10 B on substrate of Pd and Ta, with thicknesses betwnn 30μg/cm 2 and 500μg/cm 2 were measured with a precision of 5%. The biggest sources of imprecision are the amounts of dE/dX. (Author) [pt

  12. Space- and time-resolved resistive measurements of liquid metal wall thickness

    Energy Technology Data Exchange (ETDEWEB)

    Mirhoseini, S. M. H.; Volpe, F. A., E-mail: fvolpe@columbia.edu [Department of Applied Physics and Applied Mathematics, Columbia University, New York, New York 10027 (United States)

    2016-11-15

    In a fusion reactor internally coated with liquid metal, it will be important to diagnose the thickness of the liquid at various locations in the vessel, as a function of time, and possibly respond to counteract undesired bulging or depletion. The electrical conductance between electrodes immersed in the liquid metal can be used as a simple proxy for the local thickness. Here a matrix of electrodes is shown to provide spatially and temporally resolved measurements of liquid metal thickness in the absence of plasma. First a theory is developed for m × n electrodes, and then it is experimentally demonstrated for 3 × 1 electrodes, as the liquid stands still or is agitated by means of a shaker. The experiments were carried out with Galinstan, but are easily extended to lithium or other liquid metals.

  13. Thickness Measurement of a Film on a Substrate by Low-Frequency Ultrasound

    Institute of Scientific and Technical Information of China (English)

    LI Ming-Xuan; WANG Xiao-Min; MAO Jie

    2004-01-01

    @@ We describe a new simple technique for the low-frequency ultrasonic thickness measurement of an air-backed soft thin layer attached on a hard substrate of finite thickness through the frequency-shifts of the substrate resonances by the substrate-side insonification. A plane compressive wave impinging normally on the substrate surface from a liquid is studied. Low frequency here means an interrogating acoustical wave frequency of less than half of coating to the substrate. Equations for the frequency-shifts are derived and solved by the Newton iterative method and the Taylor expansion method, respectively, indicating satisfactory agreement within the range of interest of thickness ratio of the thin layer to the substrate for a polymer-aluminium structure. An experimental setup is constructed to verify the validity of the technique.

  14. Space- and time-resolved resistive measurements of liquid metal wall thickness

    International Nuclear Information System (INIS)

    Mirhoseini, S. M. H.; Volpe, F. A.

    2016-01-01

    In a fusion reactor internally coated with liquid metal, it will be important to diagnose the thickness of the liquid at various locations in the vessel, as a function of time, and possibly respond to counteract undesired bulging or depletion. The electrical conductance between electrodes immersed in the liquid metal can be used as a simple proxy for the local thickness. Here a matrix of electrodes is shown to provide spatially and temporally resolved measurements of liquid metal thickness in the absence of plasma. First a theory is developed for m × n electrodes, and then it is experimentally demonstrated for 3 × 1 electrodes, as the liquid stands still or is agitated by means of a shaker. The experiments were carried out with Galinstan, but are easily extended to lithium or other liquid metals.

  15. Mediterranean diet, micronutrients and macronutrients, and MRI measures of cortical thickness.

    Science.gov (United States)

    Staubo, Sara C; Aakre, Jeremiah A; Vemuri, Prashanthi; Syrjanen, Jeremy A; Mielke, Michelle M; Geda, Yonas E; Kremers, Walter K; Machulda, Mary M; Knopman, David S; Petersen, Ronald C; Jack, Clifford R; Roberts, Rosebud O

    2017-02-01

    The Mediterranean diet (MeDi) is associated with reduced risk of cognitive impairment, but it is unclear whether it is associated with better brain imaging biomarkers. Among 672 cognitively normal participants (mean age, 79.8 years, 52.5% men), we investigated associations of MeDi score and MeDi components with magnetic resonance imaging measures of cortical thickness for the four lobes separately and averaged (average lobar). Higher MeDi score was associated with larger frontal, parietal, occipital, and average lobar cortical thickness. Higher legume and fish intakes were associated with larger cortical thickness: legumes with larger superior parietal, inferior parietal, precuneus, parietal, occipital, lingual, and fish with larger precuneus, superior parietal, posterior cingulate, parietal, and inferior parietal. Higher carbohydrate and sugar intakes were associated with lower entorhinal cortical thickness. In this sample of elderly persons, higher adherence to MeDi was associated with larger cortical thickness. These cross-sectional findings require validation in prospective studies. Copyright © 2016 the Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  16. Measuring the thickness of austenitic weld deposits on carbon steel walls using a magnetic method

    International Nuclear Information System (INIS)

    Wagner, K.

    1988-01-01

    The theoretical background is described of a magnetic method characterized by a marked compensation of the undesirable effect of δ-ferrite content in the deposit, on the accuracy of measuring deposit thickness. A description is also given of the basic types of sensors and the results are summarized of comparing measurements performed on weld deposits of WWER-type reactor pressure vessels. (author). 7 figs., 5 refs

  17. Influence of veneer thickness on residual stress profile in veneering ceramic: measurement by hole-drilling.

    Science.gov (United States)

    Mainjot, Amélie K; Schajer, Gary S; Vanheusden, Alain J; Sadoun, Michaël J

    2012-02-01

    The veneering process of frameworks induces residual stresses and can initiate cracks when combined with functional stresses. The stress distribution within the veneering ceramic as a function of depth is a key factor influencing failure by chipping. This is a well-known problem with Yttria-tetragonal-zirconia-polycrystal based fixed partial dentures. The objective of this study is to investigate the influence of veneer thickness on the stress profile in zirconia- and metal-based structures. The hole-drilling method, often used for engineering measurements, was adapted for use with veneering ceramic. The stress profile was measured in bilayered disc samples of 20 mm diameter, with a 1 mm thick zirconia or metal framework. Different veneering ceramic thicknesses were performed: 1 mm, 1.5 mm, 2 mm, 2.5 mm and 3 mm. All samples exhibited the same type of stress vs. depth profile, starting with compressive at the ceramic surface, decreasing with depth up to 0.5-1.0 mm from the surface, and then becoming compressive again near the framework, except for the 1.5 mm-veneered zirconia samples which exhibited interior tensile stresses. Stresses in the surface of metal samples were not influenced by veneer thickness. Variation of interior stresses at 1.2 mm from the surface in function of veneer thickness was inverted for metal and zirconia samples. Veneer thickness influences in an opposite way the residual stress profile in metal- and in zirconia-based structures. A three-step approach and the hypothesis of the crystalline transformation are discussed to explain the less favorable residual stress development in zirconia samples. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Macular micropseudocysts in early stages of diabetic retinopathy.

    Science.gov (United States)

    Tremolada, Gemma; Pierro, Luisa; de Benedetto, Umberto; Margari, Sergio; Gagliardi, Marco; Maestranzi, Gisella; Calori, Giliola; Lorenzi, Mara; Lattanzio, Rosangela

    2011-01-01

    To identify by noninvasive means early retinal abnormalities that may predict diabetic macular edema. The authors analyzed retrospectively data from consecutive patients with Type 1 (n = 16) or Type 2 (n = 23) diabetes who presented for routine follow-up of early retinopathy, had no clinical signs or symptoms of diabetic macular edema, and were evaluated with spectral-domain optical coherence tomography. Age- and gender-matched nondiabetic subjects provided normative data. Spectral-domain optical coherence tomography revealed in the macular region of diabetic patients small hyporeflective areas (median diameter, 55 μm) contained within discrete retinal layers that we named micropseudocysts (MPCs). Micropseudocysts are associated with vascular leakage. The patients showing MPCs had more frequently systemic hypertension and increased central foveal thickness than those without MPCs. The association with increased central foveal thickness was only in the patients with Type 2 diabetes. Macular MPCs in patients with mild diabetic retinopathy appear to reflect leakage and can precede macular thickening. The association of MPCs with increased central foveal thickness in patients with Type 2 diabetes, but not in patients with Type 1 diabetes, points to a greater tendency to retinal fluid accumulation in patients with Type 2 diabetes. Studies in larger cohorts will determine the usefulness of MPCs in strategies to abort diabetic macular edema.

  19. The Usefulness of Visceral Fat Thickness Measured by Ultrasonography as an Abdominal Obesity Index

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Kyun [Dept. of Diagnostic Radiology, Korealife Daejeon Healthcare Center, Daejeon (Korea, Republic of); Han, Man Seok [Dept. of Diagnostic Radiology, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2008-09-15

    Abdominal obesity with visceral fat accumulation have been known to be intimately associated with the development of metabolic syndrome. Therefore, it is important to estimate the precise amount of visceral fat. Ultrasonography has been reported that it is a simple and noninvasive method for visceral fat evaluation. Purpose of this study is to evaluate the association of ultrasonographic visceral fat thickness, anthropometric indexes, and risk factor of metabolic syndrome, and to investigate the cut-off value of abdominal visceral fat thickness leading to increased risk of metabolic syndrome. The subject included 200 men and 200 women who visited D healthcare center in Daejeon from January to April 2008. The subcutaneous fat thickness and visceral fat thickness were measured by ultrasonograph. As anthropometric index, we measured body mass index, waist circumference and waist/height ratio. As for the risk factor of metabolic syndrome, we measured blood pressure, high density lipoprotein cholesterol, triglyceride and fasting serum glucose. VFT was significantly correlated with waist circumference, (r=0.683/M, r=0.604/F), waist to height ratio (r=0.633/M, r=0.593/F) and BMI (r=0.621/M, r=0.534/F) in both men and women. In addition it was significantly correlated with Systolic blood pressure (r=0.229/M, r=0.232/F), Diastolic blood pressure ((r=0.285/M, r=0.254/F), high density cholesterol (r=-0.254/M, r=-0.254/F), Triglyceride (r=0.475/M, r=0.411/F), and Fasting blood sugar (r=0.158/M, r=0.234/F) in both men and women. The cut-off value of visceral fat thickness leading to the increased risk of metabolic syndrome was 4.58 cm (sensitivity 89.2%, specificity 71.2%) in men and 3.50 cm (sensitivity 61.2% specificity 80.8%) in women respectively. The odds ratio of the risk of metabolic syndrome was dramatically increased with the abdominal visceral fat thickness level over 6 cm in men and 5 cm in women. The visceral fat thickness using ultrasonography was significantly

  20. The Usefulness of Visceral Fat Thickness Measured by Ultrasonography as an Abdominal Obesity Index

    International Nuclear Information System (INIS)

    Kim, Yong Kyun; Han, Man Seok

    2008-01-01

    Abdominal obesity with visceral fat accumulation have been known to be intimately associated with the development of metabolic syndrome. Therefore, it is important to estimate the precise amount of visceral fat. Ultrasonography has been reported that it is a simple and noninvasive method for visceral fat evaluation. Purpose of this study is to evaluate the association of ultrasonographic visceral fat thickness, anthropometric indexes, and risk factor of metabolic syndrome, and to investigate the cut-off value of abdominal visceral fat thickness leading to increased risk of metabolic syndrome. The subject included 200 men and 200 women who visited D healthcare center in Daejeon from January to April 2008. The subcutaneous fat thickness and visceral fat thickness were measured by ultrasonograph. As anthropometric index, we measured body mass index, waist circumference and waist/height ratio. As for the risk factor of metabolic syndrome, we measured blood pressure, high density lipoprotein cholesterol, triglyceride and fasting serum glucose. VFT was significantly correlated with waist circumference, (r=0.683/M, r=0.604/F), waist to height ratio (r=0.633/M, r=0.593/F) and BMI (r=0.621/M, r=0.534/F) in both men and women. In addition it was significantly correlated with Systolic blood pressure (r=0.229/M, r=0.232/F), Diastolic blood pressure ((r=0.285/M, r=0.254/F), high density cholesterol (r=-0.254/M, r=-0.254/F), Triglyceride (r=0.475/M, r=0.411/F), and Fasting blood sugar (r=0.158/M, r=0.234/F) in both men and women. The cut-off value of visceral fat thickness leading to the increased risk of metabolic syndrome was 4.58 cm (sensitivity 89.2%, specificity 71.2%) in men and 3.50 cm (sensitivity 61.2% specificity 80.8%) in women respectively. The odds ratio of the risk of metabolic syndrome was dramatically increased with the abdominal visceral fat thickness level over 6 cm in men and 5 cm in women. The visceral fat thickness using ultrasonography was significantly

  1. Non-contact Measurement of Remaining Thickness of Corroding Superheater Tubes. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Borggreen, Kjeld; Storesund, Jan

    2006-10-15

    Corrosion of superheaters has become a severe problem in many biomass boilers and incineration plants. This new situation calls for frequent tube wall thickness testing of the superheaters during very short shut-downs. To meet this demand Electro Magnetic Acoustic Transducer (EMAT) candidates as substitute for conventional manually operated contact UT-transducers. The EMAT can contactlessly generate an ultrasonic wave in the interphase between the external oxide and the metal. This means that measurements can be undertaken much quicker and with a much higher coverage simultaneously, without preceding blast operations. It is the aim of the project to demonstrate the usefulness of two simple EMAT systems, Panametrics and Sonatest, for fast and reliable tube thickness inspections in difficult-to-access superheater sections. The present Phase 1 of the project involves testing of the performance of the two systems in laboratory with the following results: 1. Both instruments work well on plate, tube, and pipe samples assuming the presence of an external oxide layer formed at a temperature above approximately 400 deg C. 2. Both instruments work well on all types of ferritic and martensitic steels but not on austenitic steels. 3. Both instruments work well independent of the thickness of the active oxide layer. 4. Both instruments work well independent of tube diameter, wall thickness, and sample width. 5. Both instruments work well over a very large range of wall thicknesses. Minimum tube wall thickness is less than 1.8 mm. 6. The tolerable lift-off (free distance between transducer and tube surface) is 2.4 - 3.0 mm for Panametrics system and 3.6 - 4.8 mm for Sonatest's system. The tolerable lift-off is a measure of the thickness of ash deposits, which can be tolerated on the tube surface as well as the misplacement, which can be tolerated in case of remote tube testing. 7. The tolerable off-set between tube axis and probe axis is very large for both instruments (10

  2. Ultrasound-based measurement of liquid-layer thickness: A novel time-domain approach

    Science.gov (United States)

    Praher, Bernhard; Steinbichler, Georg

    2017-01-01

    Measuring the thickness of a thin liquid layer between two solid materials is important when the adequate separation of metallic parts by a lubricant film (e.g., in bearings or mechanical seals) is to be assessed. The challenge in using ultrasound-based systems for such measurements is that the signal from the liquid layer is a superposition of multiple reflections. We have developed an algorithm for reconstructing this superimposed signal in the time domain. By comparing simulated and measured signals, the time-of-flight of the ultrasonic pulse in a layer can be estimated. With the longitudinal sound velocity known, the layer thickness can then be calculated. In laboratory measurements, we validate successfully (maximum relative error 4.9%) our algorithm for layer thicknesses ranging from 30 μm to 200 μm. Furthermore, we tested our method in the high-temperature environment of polymer processing by measuring the clearance between screw and barrel in the plasticisation unit of an injection moulding machine. The results of such measurements can indicate (i) the wear status of the tribo-mechanical screw-barrel system and (ii) unsuitable process conditions.

  3. Cystoid macular edema

    Directory of Open Access Journals (Sweden)

    Tryfon G Rotsos

    2008-10-01

    Full Text Available Tryfon G Rotsos1, Marilita M Moschos21Medical Retina Service, Moorfields Eye Hospital, London, UK; 2Department of Ophthalmology, University of Athens, GreeceAbstract: We review the epidemiology, pathophysiology, and etiology of cystoid macular edema (CME. Inflammatory, diabetic, post-cataract, and macular edema due to age-related macular degeneration is described. The role of chronic inflammation and hypoxia and direct macular traction is evaluated in each case according to different views from the literature. The different diagnostic methods for evaluating the edema are described. Special attention is given to fluoroangiography and the most modern methods of macula examination, such as ocular coherence tomography and multifocal electroretinography. Finally, we discuss the treatment of cystoid macular edema in relation to its etiology. In this chapter we briefly refer to the therapeutic value of laser treatment especially in diabetic maculopathy or vitrectomy in some selected cases. Our paper is focused mainly on recent therapeutic treatment with intravitreal injection of triamcinolone acetonide and anti-VEGF factors like bevacizumab (Avastin, ranibizumab (Lucentis, pegaptamid (Macugen, and others. The goal of this paper is to review the current status of this treatment for macular edema due to diabetic maculopathy, central retinal vein occlusion and post-cataract surgery. For this reason the results of recent multicenter clinical trials are quoted, as also our experience on the use of intravitreal injections of anti-VEGF factors and we discuss its value in clinical practice.Keywords: cystoid macular edema, anti-VEGF, fluoroangiography, OCT, multifocal electroretinography

  4. Visual recovery after surgical repair of chronic macular detachment associated with peripheral retinoschisis

    OpenAIRE

    Vaidehi S. Dedania; Devon H. Ghodasra; Mark W. Johnson

    2018-01-01

    Purpose: To report 2 cases of chronic macular detachment associated with peripheral retinoschisis in which surgical repair resulted in significant visual recovery. Observations: A 44-year-old man and 60-year-old woman were evaluated for chronic macular detachment, with a duration of 5 years and 6 months, respectively. In each case, optical coherence tomography was used to establish a diagnosis of full-thickness macular detachment resulting from peripheral retinoschisis and to confirm or ident...

  5. Hyperbaric oxygen therapy for the treatment of radiation-induced macular ischemia

    Directory of Open Access Journals (Sweden)

    Shamim A Haji

    2010-05-01

    Full Text Available Shamim A Haji1,2, Ronald EP Frenkel1,2,31Eye Research Foundation, Stuart, FL, USA; 2East Florida Eye Institute, Stuart, FL, USA; 3Bascom Palmer Eye Institute, Miami, FL, USAPurpose: To report a case of radiation-induced macular ischemia where vision and macular perfusion improved after hyperbaric oxygen (HBO therapy.Methods: A 62-year-old male patient developed radiation-induced macular ischemia after he was treated with radiation for brain glioma. The patient presented with best spectacle-corrected visual acuity (BSCVA acuity of 20/400 in his right eye. Optical coherence tomography (OCT showed central macular thickness of 468 μm. The patient received focal laser, intravitreal triamcinolone, and HBO therapy.Results: The patient’s vision improved from 20/400 to 20/100 after focal laser and intravitreal triamcinolone. His central macular thickness improved from 468 μm to 132 μm. After receiving HBO therapy, his VA improved to 20/50 and fluorescein angiography showed improvement in macular perfusion.Conclusion: HBO therapy improves macular perfusion in patients with radiation-induced macular ischemia.Keywords: macular ischemia, visual acuity, hyperbaric oxygen therapy, macular perfusion

  6. Sea ice thickness measurements collected during the LOMROG 2007 and 2009 expeditions

    DEFF Research Database (Denmark)

    Skourup, Henriette; Forsberg, René; Hanson, Susanne

    and 2009 we have collected a unique data set of late summer sea ice thickness, freeboard height and snow depth from the high Arctic Ocean during the time of the annual minimum sea ice extent. The data were collected by on-the-ground drilling and EM measurements. Here we give a brief overview of the data......According to scientific measurements, the Arctic sea ice extent has declined dramatically over the past thirty years, with the most extreme decline seen in the summer melt season. Other observations indicate that the sea ice has become thinner and perennial ice less widely distributed...... collection, as well as the results including the freeboard-to-sea-ice thickness conversion factor, which is used when interpreting freeboard heights measured by remote sensing....

  7. Simultaneous refractive index and thickness measurement with the transmission interferometric adsorption sensor

    Energy Technology Data Exchange (ETDEWEB)

    Sannomiya, Takumi; Voeroes, Janos [Laboratory of Biosensors and Bioelectronics, Department of Information Technology and Electrical Engineering, ETH Zurich, 8092, Zurich (Switzerland); Balmer, Tobias E [Materials Research Center, ETH Zurich, 8093, Zurich (Switzerland); Heuberger, Manfred, E-mail: sannomiya@biomed.ee.ethz.c, E-mail: tobias.balmer@mat.ethz.c, E-mail: manfred.heuberger@empa.c, E-mail: janos.voros@biomed.ee.ethz.c [Laboratory for Surface Science and Technology, Department of Materials, ETH Zurich, 8093, Zurich (Switzerland)

    2010-10-13

    Refractive index and thickness of the adlayer are determined simultaneously using the transmission interferometric adsorption sensor (TInAS). Optical biosensors, where both refractive index and thickness of a homogeneous adlayer (thus the adsorbed mass) are determined simultaneously, so-called model-free biosensors, are important tools to investigate the adsorbed mass of biomolecules with unknown conformation. Our proposed calculation method enables model-free biosensing from a single spectrum acquired by a simple TInAS setup, namely using information of peak/dip positions as well as peak/dip intensities. The feasibility of this method was experimentally tested by adsorbing polyelectrolyte multilayer as well as biomolecules. To validate the new method also for the more intricate heterogeneous adlayer, the apparent refractive index and thickness were assessed theoretically by simulating a selection of different adsorbate configurations with the multiple multipole program (MMP). We found that a lateral inhomogeneity of the adsorbate (e.g. islands or adsorbed colloids) results in correct thickness and in reduced refractive index averaged in proportion to their density while vertically inhomogeneous density caused more complex responses. However, the apparent mass was always correct. Measurement errors can lead to significant errors in the apparent refractive index, particularly when the adlayer is very thin (<5 nm). This model-free TInAS technique would be useful not only for the measurement of adsorbed mass but also for the conformational analysis of the adsorbed molecules.

  8. Measurements of the dependence of damage thresholds on laser wavelength, pulse duration and film thickness

    International Nuclear Information System (INIS)

    Rainer, F.; Vercimak, C.L.; Carniglia, C.K.; Milam, D.; Hart, T.T.

    1985-01-01

    Results of three experiments are described. The authors used 351-nm and 355-nm pulses with durations of 0.6, 1, 5 and 9 ns to measure thresholds for a variety of antireflectance and high reflectance coatings. The functional form t/sup m/, with t the pulse duration, was used to scale fluence thresholds measured at 0.6 ns to those measured at 9.0 ns. Values of the coefficient m ranged from 0.10 to 0.51. The average value was 0.30. In the second experiment, they measured thresholds at 1064 nm, 527 nm and 355 nm for single-frequency high reflectance ZrO/sub 2//SiO/sub 2/ coatings. Coatings for all three frequencies were deposited simultaneously by use of masks in the coating chamber. Thresholds varied from 2-4 J/cm/sup 2/ at 355 nm to 7-10 J/cm/sup 2/ at 1064 nm. The third experiment measured thresholds at 355 nm for antireflection coatings made with layer thicknesses varying from greater than one wavelength to less than a quarterwavelength. A significant variation of threshold with coating thickness was not observed, but the median thresholds increased slightly as coating thickness increased

  9. Terahertz thickness measurements for real industrial applications: from automotive paints to aerospace industry (Conference Presentation)

    Science.gov (United States)

    Krimi, Soufiene; Beigang, René

    2017-02-01

    In this contribution, we present a highly accurate approach for real-time thickness measurements of multilayered coatings using terahertz time domain spectroscopy in reflection geometry. The proposed approach combines the benefits of a model-based material parameters extraction method to calibrate the specimen under test, a generalized modeling method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity and the precision of the minimum thickness measurement limit. Furthermore, a novel self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wet spray in the car painting process and the influence of the spraying conditions and the sintering process on ceramic thermal barrier coatings (TBCs) in aircraft industry. In addition, the developed approach enables for some applications the simultaneous determination of the complex refractive index and the coating thickness. Hence, a pre-calibration of the specimen under test is not required for such cases. Due to the high robustness of the self-calibration method and the genetic optimization algorithms, the approach has been successfully applied to resolve individual layer thicknesses within multi-layered coated samples down to less than 10 µm. The regression method can be applied in time-domain, frequency-domain or in both the time and frequency-domain simultaneously. The data evaluation uses general-purpose computing on graphics processing units and thanks to the developed highly parallelized algorithm lasts less than 300 ms. Thus, industrial requirements for fast thickness measurements with an "every-second-cycle" can be fulfilled.

  10. Ultrasonographic evaluation of reproductive tract measures and fat thickness traits in pre-pubertal Nellore heifers

    Directory of Open Access Journals (Sweden)

    Fabio Morato Monteiro

    2012-02-01

    Full Text Available The aim of this study was to evaluate the relationship between reproductive tract and fat thickness measures obtained by ultrasound in prepubertal Nellore heifers. A total of 128 Nellore heifers born in 2006 and 2007 were submitted to ultrasound evaluations (13, 16, 19 and 22 months of age of reproductive tract measures and fat thickness traits. These animals were from a selection experiment (NeC: control line, and NeS: selection line for yearling weight started in 1981. Mean values of ovary area, height of the right uterine horn (HU, maximum follicular diameter (FOL, backfat thickness (BF, rump fat thickness (RF, and body condition score were analyzed. Repeated records were modeled using the PROC MIXED procedure (SAS, fitting a model that included the selection line, year of birth, measurement as fixed effects, and interactions. Body weight differed between the selected (281.48 kg and control (210.51 kg lines. Only the least square means of FOL were lower in the NeC line compared to the NeS line (P < 0.05, although the difference in mean HU between the two lines was of only borderline significance (P = 0.06. The rate of growth for the three reproductive traits was similar in the two lines. Simple and residual correlations between the reproductive and subcutaneous fat traits ranged from low to medium. The highest correlations were observed between HU and RF (Pearson correlation = 0.71 and residual correlation = 0.34. The current results are consistent with the literature, indicating that fat thickness traits are not good predictors of prepubertal reproductive traits in heifers. Further studies are necessary to clarify the relationship between reproduction and body fat in Nellore heifers.

  11. Measurement of Choroidal Perfusion and Thickness Following Systemic Sildenafil (Viagra®)

    Science.gov (United States)

    Kim, David Y.; Silverman, Ronald H.; Chan, R.V. Paul; Khanifar, Aziz A.; Rondeau, Mark; Lloyd, Harriet; Schlegel, Peter; Coleman, D. Jackson

    2011-01-01

    Objective To demonstrate anatomic and physiologic changes in the human choroid following systemic sildenafil citrate (ViagraR) using enhanced depth imaging spectral domain-optical coherence tomography (EDI-OCT) and swept-scan high frequency digital ultrasound. Methods Seven healthy male subjects (mean age 32.7 years) were evaluated at baseline and two hours after ingesting 50 mg of sildenafil. Swept-scan high frequency digital ultrasound and EDI-OCT were utilized to measure choroidal perfusion and thickness, respectively. Results were read by masked observers. The Wilcoxon signed-rank test and t-test were used to analyze differences in choroidal flow and thickness at baseline and two hours after ingestion of sildenafil. Results Two hours following sildenafil, increased choroidal perfusion was observed in 11 of 12 eyes measured by swept-scan high frequency digital ultrasound. The mean increase was 3.46 (±2.00) times baseline with a range of 0.47 to 7.80 times baseline (p=0.004). Increased choroidal thickness was observed in 12 of 12 eyes measured with EDI-OCT. The average choroidal thickness increased by 11.6% temporal to the fovea, 9.3% nasal to the fovea, and 10.7% underneath the fovea (p<0.001 for all values). Conclusions Choroidal perfusion and thickness both increase in response to systemic sildenafil. These changes could secondarily affect retinal function, explain previously reported clinical symptoms, and potentially be a useful adjunct for treatment of ocular diseases that would benefit from increased choroidal blood flow. PMID:22974308

  12. Novel method for the measurement of liquid film thickness during fuel spray impingement on surfaces.

    Science.gov (United States)

    Henkel, S; Beyrau, F; Hardalupas, Y; Taylor, A M K P

    2016-02-08

    This paper describes the development and application of a novel optical technique for the measurement of liquid film thickness formed on surfaces during the impingement of automotive fuel sprays. The technique makes use of the change of the light scattering characteristics of a metal surface with known roughness, when liquid is deposited. Important advantages of the technique over previously established methods are the ability to measure the time-dependent spatial distribution of the liquid film without a need to add a fluorescent tracer to the liquid, while the measurement principle is not influenced by changes of the pressure and temperature of the liquid or the surrounding gas phase. Also, there is no need for non-fluorescing surrogate fuels. However, an in situ calibration of the dependence of signal intensity on liquid film thickness is required. The developed method can be applied to measure the time-dependent and two-dimensional distribution of the liquid fuel film thickness on the piston or the liner of gasoline direct injection (GDI) engines. The applicability of this technique was evaluated with impinging sprays of several linear alkanes and alcohols with different thermo-physical properties. The surface temperature of the impingement plate was controlled to simulate the range of piston surface temperatures inside a GDI engine. Two sets of liquid film thickness measurements were obtained. During the first set, the surface temperature of the plate was kept constant, while the spray of different fuels interacted with the surface. In the second set, the plate temperature was adjusted to match the boiling temperature of each fuel. In this way, the influence of the surface temperature on the liquid film created by the spray of different fuels and their evaporation characteristics could be demonstrated.

  13. Chest wall thickness measurements and the dosimetric implications for male workers in the uranium industry

    International Nuclear Information System (INIS)

    Kramer, Gary H.; Hauck, Barry M.; Allen, Steve A.

    2000-01-01

    The Human Monitoring Laboratory has measured the chest wall thickness and adipose mass fraction of a group of workers at three Canadian uranium refinery, conversion plant, and fuel fabrication sites using ultrasound. A site specific biometric equation has been developed for these workers, who seem to be somewhat larger than other workers reported in the literature. The average chest wall thickness of the seated persons measured at the uranium conversion plant and refinery was about 3.8 cm, and at the fuel fabrication facility was 3.4 cm. These values are not statistically different. Persons measured in a seated geometry had a thinner chest wall thickness than persons measured in a supine geometry - the decrease was in the range of 0.3 cm to 0.5 cm. It follows that a seated geometry will give a lower MDA (or decision level) than a supine geometry. Chest wall thickness is a very important modifier for lung counting efficiency and this data has been put into the perspective of the impending Canadian dose limits that will reduce the limit of occupationally exposed workers to essentially 20 mSv per year. Natural uranium must be measured based on the 235 U emissions at these type of facilities. The refining and conversion process removes 234 Th and the equilibrium is disturbed. This is unfortunate as the MDA values for this nuclide are approximately a factor of three lower than the values quoted below. The sensitivity of the germanium and phoswich based lung counting system has been compared. Achievable MDA's (30 minute counting time) with a four-phoswich-detector array lie in the range of 4.7 mg to 13.5 mg of natural uranium based on the 235 U emissions over a range of chest wall thicknesses of 1.6 cm to 6.0 cm. The average achievable MDA is about 8.5 mg which can be reduced to about 6.2 mg by doubling the counting time. Similarly, MDA's (30 minute counting time) obtainable with a germanium lung counting system will lie in the range of 3 mg to 28 mg of natural uranium

  14. A reliable control system for measurement on film thickness in copper chemical mechanical planarization system

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hongkai; Qu, Zilian; Zhao, Qian; Tian, Fangxin; Zhao, Dewen; Meng, Yonggang; Lu, Xinchun [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China)

    2013-12-15

    In recent years, a variety of film thickness measurement techniques for copper chemical mechanical planarization (CMP) are subsequently proposed. In this paper, the eddy-current technique is used. In the control system of the CMP tool developed in the State Key Laboratory of Tribology, there are in situ module and off-line module for measurement subsystem. The in situ module can get the thickness of copper film on wafer surface in real time, and accurately judge when the CMP process should stop. This is called end-point detection. The off-line module is used for multi-points measurement after CMP process, in order to know the thickness of remained copper film. The whole control system is structured with two levels, and the physical connection between the upper and the lower is achieved by the industrial Ethernet. The process flow includes calibration and measurement, and there are different algorithms for two modules. In the process of software development, C++ is chosen as the programming language, in combination with Qt OpenSource to design two modules’ GUI and OPC technology to implement the communication between the two levels. In addition, the drawing function is developed relying on Matlab, enriching the software functions of the off-line module. The result shows that the control system is running stably after repeated tests and practical operations for a long time.

  15. Residual stress measurements in thick structural weldments by means of neutron diffraction

    International Nuclear Information System (INIS)

    Ohms, C.; Youtsos, A.G.; Idsert, P. v.d.; Timke, T.

    2000-01-01

    Welding residual stresses in large structural components are a major concern with respect to their performance and lifetime. In large structures reasonable thermal stress relief treatment is usually impossible due to the component size. On the other hand, prediction of welding stresses by numerical modelling has not yet proven to be generally reliable, while the experimental determination of such stresses remains a demanding task. At the high flux reactor (HFR), Petten, a new residual stress diffractometer has been installed recently capable of handling of components up to 1000 kg - the large component neutron diffraction facility (LCNDF). It has facilitated residual stress measurements in two large welded components, of which results are presented here. The first component represents a bi-metallic weld in form of a pipe of 25 mm wall thickness. Three dimensional measurements of residual stress are discussed in detail. The second specimen is a 66 mm wall thickness austenitic steel nuclear piping weld. Results on relief of strain within the weld through post weld heat treatment (PWHT) are presented. Additionally results obtained earlier at former CRNL (CAN) on a section of a thick nuclear piping weld are presented in order to illustrate the variation in the reference lattice parameter trough the weld and the heat affected zone (HAZ). These results clearly show the necessity to determine the reference parameters for each location in all measurement directions by means of measurements in small coupons free of macro-stresses. (orig.)

  16. ASSOCIATIONS BETWEEN MACULAR EDEMA AND CIRCULATORY STATUS IN EYES WITH RETINAL VEIN OCCLUSION: An Adaptive Optics Scanning Laser Ophthalmoscopy Study.

    Science.gov (United States)

    Iida, Yuto; Muraoka, Yuki; Uji, Akihito; Ooto, Sotaro; Murakami, Tomoaki; Suzuma, Kiyoshi; Tsujikawa, Akitaka; Arichika, Shigeta; Takahashi, Ayako; Miwa, Yuko; Yoshimura, Nagahisa

    2017-10-01

    To investigate associations between parafoveal microcirculatory status and foveal pathomorphology in eyes with macular edema (ME) secondary to retinal vein occlusion (RVO). Ten consecutive patients (10 eyes) with acute retinal vein occlusion were enrolled, 9 eyes of which received intravitreal ranibizumab (IVR) injections. Foveal morphologic changes were examined via optical coherence tomography (OCT), and parafoveal circulatory status was assessed via adaptive optics scanning laser ophthalmoscopy (AO-SLO). The mean parafoveal aggregated erythrocyte velocity (AEV) measured by adaptive optics scanning laser ophthalmoscopy in eyes with retinal vein occlusion was 0.99 ± 0.43 mm/second at baseline, which was significantly lower than that of age-matched healthy subjects (1.41 ± 0.28 mm/second, P = 0.042). The longitudinal adaptive optics scanning laser ophthalmoscopy examinations of each patient showed that parafoveal AEV was strongly inversely correlated with optical coherence tomography-measured central foveal thickness (CFT) over the entire observation period. Using parafoveal AEV and central foveal thickness measurements obtained at the first and second examinations, we investigated associations between differences in parafoveal AEV and central foveal thickness, which were significantly and highly correlated (r = -0.84, P = 0.002). Using adaptive optics scanning laser ophthalmoscopy in eyes with retinal vein occlusion macular edema, we could quantitatively evaluate the parafoveal AEV. A reduction or an increase in parafoveal AEV may be a clinical marker for the resolution or development/progression of macular edema respectively.

  17. Computed tomographic measurement of gluteal subcutaneous fat thickness in reference to failure of gluteal intramuscular injections

    Energy Technology Data Exchange (ETDEWEB)

    Burbridge, B.E. [Univ. of Saskatchewan, Royal Univ. Hospital, Academic Dept. of Medical Imaging, Saskatoon, Saskatchewan (Canada)]. E-mail: brent.burbridge@usask.ca

    2007-04-15

    Casual observation of gluteal region fat thickness on computed tomography (CT) of the pelvis leads to the hypothesis that, in some individuals intended intramuscular injections are not properly deposited in the gluteal muscle. We gathered and analyzed data to determine whether this hypothesis was true. CT scans of the pelvis were analyzed over an 18-day period in the tall of 2005. The thickness of gluteal region subcutaneous fat was measured in a standardized manner. Measurement of gluteal region subcutaneous fat thickness was performed for 298 pelvic CT scans. There were 150 male subjects and 148 female subjects. The average gluteal fat thickness for female subjects was 33.2 mm, whereas the average for male subjects was 23.1 mm. Analysis revealed a significant difference in gluteal region fat thickness between male and female subjects. A 37-mm needle, allowing for 6-mm penetration of the gluteal muscle, would not have entered the gluteal muscle fibres in 81 of 148 female subjects (54.7%), in 21 of 150 male subjects (14%), and in 102 of the 298 total sample (34.2%). Analysis revealed a significant difference between male and female subjects with regard to gluteal muscle needle penetration. An overall predicted failure rate of 34% was identified for intended gluteal intramuscular injections when the standard technique was used. This is important information for care providers who inject medications in the gluteal region. In a significant number of patients, the medications will be injected subcutaneously and not into the gluteal musculature, possibly altering the pharmacokinetics of the administered medication. An alternative injection site should probably be chosen to increase the success rate of intramuscular deposition of medications and vaccines in unselected adults. (author)

  18. Comparison of different methods for measuring the passive film thickness on metals

    International Nuclear Information System (INIS)

    Benoit, Marie; Bataillon, Christian; Gwinner, Benoit; Miserque, Frédéric; Orazem, Mark E.; Sánchez-Sánchez, Carlos M.; Tribollet, Bernard; Vivier, Vincent

    2016-01-01

    Highlights: • In situ EIS and ex situ XPS were used for the characterization of zirconium oxide films. • The film thicknesses can be obtained from the analysis of a single EIS diagram. • A convenient graphical method to extract film properties is proposed. - Abstract: In situ electrochemical impedance spectroscopy (EIS) and ex situ X-ray photoelectron spectroscopy (XPS) measurements on electrogenerated zirconium oxide films on zirconium (Zr/ZrO_2) were used to quantify the oxide film thickness and resistivity profiles through the oxide. The EIS analysis presented here takes advantage of the high-frequency domain at which the constant-phase element (CPE) behavior of the oxide film reverts to a capacitive response and the Cole-Cole representations of the complex capacitance to extract the high-frequency capacitance of the oxide film without reference to the nature of the time-constant distribution within the oxide film. The film thickness of the ZrO_2 samples measured from the high-frequency capacitance of EIS were in good agreement with the thickness obtained from XPS. Moreover, the EIS analysis presented is based on the use of the integral solution of the power law model, which allows to obtain in one single EIS experiment, both the film thickness and the resistivity profile in the ZrO_2 film. This work suggests a convenient graphical method to extract film properties and serves to validate a key assumption of the power-law model for interpretation of CPE parameters in terms of physical properties.

  19. Measurement of resonances in 12 C + 4 He through inverse kinematics with thick targets

    International Nuclear Information System (INIS)

    Aguilera, E.F.; Lizcano, D.; Martinez Q, E.; Fernandez, M.C.; Murillo, G.; Goldberg, V.; Skorodumov, B.B.; Rogachev, G.

    2003-01-01

    The excitation function of elastic scattering for the system 12 C + 4 He to energy from 0.5 to 3.5 MeV in the center of mass system (c.m.) was measured. We use a gassy thick target and the technique of inverse kinematics which allows to make measurements at 180 degrees in c.m. Using the R matrix theory those was deduced parameters of the resonances and the results were compared with measurements reported in the literature made with other techniques. (Author)

  20. What Is Macular Edema?

    Medline Plus

    Full Text Available ... a macular hole? Jan 11, 2016 After a person develops ocular histoplasmosis, is it common that years or even decades pass before the person notices the vision changes and the disease is ...

  1. What Is Macular Edema?

    Medline Plus

    Full Text Available ... the most common form of vision loss for people with diabetes—particularly if it is left untreated. ... a macular hole? Jan 11, 2016 After a person develops ocular histoplasmosis, is it common that years ...

  2. What Is Macular Edema?

    Medline Plus

    Full Text Available ... side) vision remains. Macular edema is often a complication of diabetic retinopathy , and is the most common form of vision loss for people with diabetes—particularly if it is left untreated. Next What ...

  3. Highly accurate thickness measurement of multi-layered automotive paints using terahertz technology

    Science.gov (United States)

    Krimi, Soufiene; Klier, Jens; Jonuscheit, Joachim; von Freymann, Georg; Urbansky, Ralph; Beigang, René

    2016-07-01

    In this contribution, we present a highly accurate approach for thickness measurements of multi-layered automotive paints using terahertz time domain spectroscopy in reflection geometry. The proposed method combines the benefits of a model-based material parameters extraction method to calibrate the paint coatings, a generalized Rouard's method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity of the minimum thickness measurement limit. Within the framework of this work, a self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wet spray in the painting process.

  4. Highly accurate thickness measurement of multi-layered automotive paints using terahertz technology

    International Nuclear Information System (INIS)

    Krimi, Soufiene; Beigang, René; Klier, Jens; Jonuscheit, Joachim; Freymann, Georg von; Urbansky, Ralph

    2016-01-01

    In this contribution, we present a highly accurate approach for thickness measurements of multi-layered automotive paints using terahertz time domain spectroscopy in reflection geometry. The proposed method combines the benefits of a model-based material parameters extraction method to calibrate the paint coatings, a generalized Rouard's method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity of the minimum thickness measurement limit. Within the framework of this work, a self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wet spray in the painting process.

  5. Relation between macular morphology and treatment frequency during twelve months with ranibizumab for diabetic macular edema.

    Directory of Open Access Journals (Sweden)

    Yuki Mori

    Full Text Available To investigate whether baseline optical coherence tomography (OCT parameters can predict the treatment frequency of intravitreal ranibizumab (IVR injections during the first year in patients with diabetic macular edema (DME treated with pro re nata (PRN IVR injections.We retrospectively reviewed 68 eyes of 63 patients with center-involved DME who received IVR injections for 12 months or longer according to three monthly IVR injections followed by the PRN dosing. We measured the mean retinal thicknesses in the individual subfields of the Early Treatment Diabetic Retinopathy Study grid and evaluated the qualitative and quantitative parameters on OCT sectional images. We investigated the relationship between these OCT parameters at baseline and the number of IVR injections during the 12-month follow-up.Three loading doses were administered to 10 eyes; four to seven annualized IVR injections were administered to 34 eyes. The number of eyes that received IVR injections decreased gradually until month 6 and was almost constant from months 7 to 11. No relationships were seen between the treatment frequency and baseline systemic factors and the ophthalmic examination findings. Univariate analyses showed that the number of IVR injections during the first year was associated with the mean retinal thickness in the individual subfields and the transverse length of the disrupted external limiting membrane (ELM and ellipsoid zone of the photoreceptors. Multivariate analysis showed a significant association with the thickness in the inferior subfield alone. The treatment frequency during the 12-month follow-up was not correlated with improved visual acuity but was associated with the decrease in the central subfield thickness and disrupted ELM.The retinal thickness in the inferior subfield predicts the treatment frequency during the first year in eyes with DME treated with PRN IVR injections.

  6. Simultaneous reflectometry and interferometry for measuring thin-film thickness and curvature

    Science.gov (United States)

    Arends, A. A.; Germain, T. M.; Owens, J. F.; Putnam, S. A.

    2018-05-01

    A coupled reflectometer-interferometer apparatus is described for thin-film thickness and curvature characterization in the three-phase contact line region of evaporating fluids. Validation reflectometry studies are provided for Au, Ge, and Si substrates and thin-film coatings of SiO2 and hydrogel/Ti/SiO2. For interferometry, liquid/air and solid/air interferences are studied, where the solid/air samples consisted of glass/air/glass wedges, cylindrical lenses, and molded polydimethylsiloxane lenses. The liquid/air studies are based on steady-state evaporation experiments of water and isooctane on Si and SiO2/Ti/SiO2 wafers. The liquid thin-films facilitate characterization of both (i) the nano-scale thickness of the absorbed fluid layer and (ii) the macro-scale liquid meniscus thickness, curvature, and curvature gradient profiles. For our validation studies with commercial lenses, the apparatus is shown to measure thickness profiles within 4.1%-10.8% error.

  7. Refinement of Out of Circularity and Thickness Measurements of a Cylinder for Finite Element Analysis

    Science.gov (United States)

    2016-09-01

    refined finite element model. Note that the longitudinal seam weld at θ = 0° (= 360°) runs along the green area and through the centre of the red...Longitudinal seam weld is a theta = 0/360 deg UNCLASSIFIED DST-Group-TN-1521 UNCLASSIFIED 7 Figure 2. Example of thickness distribution in the... weld seam at 0° is clearly evident. Inspection of similar graphs for all sections indicates similarly good comparison between the measured and

  8. Measurement of thickness of thin water film in two-phase flow by capacitance method

    International Nuclear Information System (INIS)

    Sun, R.K.; Kolbe, W.F.; Leskovar, B.; Turko, B.

    1981-09-01

    A technique has been developed for measuring water film thickness in a two-phase annular flow system by the capacitance method. An experimental model of the flow system with two types of electrodes mounted on the inner wall of a cylindrical tube has been constructed and evaluated. The apparatus and its ability to observe fluctuations and wave motions of the water film passing over the electrodes is described in some detail

  9. SU-E-I-53: Variation in Measurements of Breast Skin Thickness Obtained Using Different Imaging Modalities

    International Nuclear Information System (INIS)

    Nguyen, U; Kumaraswamy, N; Markey, M

    2014-01-01

    Purpose: To investigate variation in measurements of breast skin thickness obtained using different imaging modalities, including mammography, computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI). Methods: Breast skin thicknesses as measured by mammography, CT, ultrasound, and MRI were compared. Mammographic measurements of skin thickness were obtained from published studies that utilized standard positioning (upright) and compression. CT measurements of skin thickness were obtained from a published study of a prototype breast CT scanner in which the women were in the prone position and the breast was uncompressed. Dermatological ultrasound exams of the breast skin were conducted at our institution, with the subjects in the upright position and the breast uncompressed. Breast skin thickness was calculated from breast MRI exams at our institution, with the patient in the prone position and the breast uncompressed. Results: T tests for independent samples demonstrated significant differences in the mean breast skin thickness as measured by different imaging modalities. Repeated measures ANOVA revealed significant differences in breast skin thickness across different quadrants of the breast for some modalities. Conclusion: The measurement of breast skin thickness is significantly different across different imaging modalities. Differences in the amount of compression and differences in patient positioning are possible reasons why measurements of breast skin thickness vary by modality

  10. Aqueous vascular endothelial growth factor and aflibercept concentrations after bimonthly intravitreal injections of aflibercept for age-related macular degeneration.

    Science.gov (United States)

    Sawada, Tomoko; Wang, Xiying; Sawada, Osamu; Saishin, Yoshitsugu; Ohji, Masahito

    2018-01-01

    Clinical evidence supports the efficacy of bimonthly aflibercept injection for age-related macular degeneration. The study aimed to evaluate aqueous vascular endothelial growth factor and aflibercept concentrations and the efficacy of bimonthly aflibercept in patients with age-related macular degeneration. This study is a prospective, interventional case series. Enrolled were 35 eyes with exudative age-related macular degeneration from 35 patients. Patients received three bimonthly intravitreal aflibercept without loading doses. We collected the aqueous humor just before each injection, measured vascular endothelial growth factor and aflibercept concentrations by enzyme-linked immunosorbent assay and measured best-corrected visual acuity and central retinal subfield thickness before and after the injections. Aqueous vascular endothelial growth factor and aflibercept concentrations were measured. The vascular endothelial growth factor concentration was 135.4 ± 60.5 pg/mL (mean ± standard deviation, range 60.6-323.4) at baseline and below the lowest detectable limit in all eyes at month 2 and in 32 eyes at month 4 (P age-related macular degeneration. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  11. Semi-automated Digital Imaging and Processing System for Measuring Lake Ice Thickness

    Science.gov (United States)

    Singh, Preetpal

    Canada is home to thousands of freshwater lakes and rivers. Apart from being sources of infinite natural beauty, rivers and lakes are an important source of water, food and transportation. The northern hemisphere of Canada experiences extreme cold temperatures in the winter resulting in a freeze up of regional lakes and rivers. Frozen lakes and rivers tend to offer unique opportunities in terms of wildlife harvesting and winter transportation. Ice roads built on frozen rivers and lakes are vital supply lines for industrial operations in the remote north. Monitoring the ice freeze-up and break-up dates annually can help predict regional climatic changes. Lake ice impacts a variety of physical, ecological and economic processes. The construction and maintenance of a winter road can cost millions of dollars annually. A good understanding of ice mechanics is required to build and deem an ice road safe. A crucial factor in calculating load bearing capacity of ice sheets is the thickness of ice. Construction costs are mainly attributed to producing and maintaining a specific thickness and density of ice that can support different loads. Climate change is leading to warmer temperatures causing the ice to thin faster. At a certain point, a winter road may not be thick enough to support travel and transportation. There is considerable interest in monitoring winter road conditions given the high construction and maintenance costs involved. Remote sensing technologies such as Synthetic Aperture Radar have been successfully utilized to study the extent of ice covers and record freeze-up and break-up dates of ice on lakes and rivers across the north. Ice road builders often used Ultrasound equipment to measure ice thickness. However, an automated monitoring system, based on machine vision and image processing technology, which can measure ice thickness on lakes has not been thought of. Machine vision and image processing techniques have successfully been used in manufacturing

  12. Human Chorioretinal Layer Thicknesses Measured in Macula-wide, High-Resolution Histologic Sections

    Science.gov (United States)

    Messinger, Jeffrey D.; Sloan, Kenneth R.; Mitra, Arnab; McGwin, Gerald; Spaide, Richard F.

    2011-01-01

    Purpose. To provide a comprehensive description of chorioretinal layer thicknesses in the normal human macula, including two-layer pairs that can produce a combined signal in some optical coherence tomography (OCT) devices (ganglion cell [GCL] and inner plexiform [IPL] layers and outer plexiform [OPL] and outer nuclear [ONL] layers). Methods. In 0.8-μm-thick, macula-wide sections through the foveola of 18 donors (age range, 40–92 years), 21 layers were measured at 25 locations by a trained observer and validated by a second observer. Tissue volume changes were assessed by comparing total retinal thickness in ex vivo OCT and in sections. Results. Median tissue shrinkage was 14.5% overall and 29% in the fovea. Histologic laminar boundaries resembled those in SD-OCT scans, but the shapes of the foveolar OPL and ONL differed. Histologic GCL, IPL, and OPLHenle were thickest at 0.8. to 1, 1.5, and 0.4 mm eccentricity, respectively. ONL was thickest in an inward bulge at the foveal center. At 1 mm eccentricity, GCL, INL, and OPLHenle represented 17.3% to 21.1%, 18.0% to 18.5%, and 14.2% to 16.6% of total retinal thickness, respectively. In donors ≥70 years of age, the RPE and choroid were 17.1% and 29.6% thinner and OPLHenle was 20.8% thicker than in donors macula were generated. Newer OCT systems can separate GCL from IPL and OPLHenle from ONL, with good agreement for the proportion of retinal thickness occupied by OPLHenle in OCT and histology. The thickening of OPLHenle in older eyes may reflect Müller cell hypertrophy associated with rod loss. PMID:21421869

  13. Comparisons of Soft Tissue Thickness Measurements in Adult Patients With Various Vertical Patterns

    Directory of Open Access Journals (Sweden)

    Neslihan Seyhan Cezairli

    2017-08-01

    Full Text Available Objective: The purposes of this study were to evaluate to study soft tissue facial profile among the different vertical patterns using the Holdaway analysis and the soft tissue thickness measurements. Materials and Methods: The study sample consisted of 90 patients divided into 3 groups: low angle group (30 patients; mean age, 20.38±3.76 years, normal angle group (30 patients; mean age, 19.36±2.83 years and high angle group (30 patients; mean age, 19.44±2.14 years. The study sample, comprised a total of 90 patients (54 women and 36 men divided into low-angle, normal-angle and high angle groups based on vertical growth pattern using the SN/GoGn angle (high-angle group >37°; low-angle group <27°; and control group or normal angle group 27-37°. Facial soft-tissue thickness and Holdaway measurements were analyzed on each radiograph with Image J programme. One-way analysis of variance and post-hoc test (Tukey were used to compare Holdaway measurements and soft tissue thicknesses among the three groups. Results: Significant differences among vertical patterns were observed for the ‘gnathion’, ‘menton’, ‘stomion’ and ‘inferior sulcus to H line’ when both genders were combined. These measurements were thinner in the high-angle group. Significant differences among vertical patterns were observed for ‘gnathion’ and ‘lower lip to H line’ in women; for ‘stomion’ and ‘nose prominence’ in men when examined separately. Conclusion: Facial soft tissue measurements except some for in high angle group were thinner than in low angle group. All soft tissue measurements were greater except for gnathion in low angle group in men than in women.

  14. Optical instrument for measurement of vaginal coating thickness by drug delivery formulations

    International Nuclear Information System (INIS)

    Henderson, Marcus H.; Peters, Jennifer J.; Walmer, David K.; Couchman, Grace M.; Katz, David F.

    2005-01-01

    An optical device has been developed for imaging the human vaginal epithelial surfaces, and quantitatively measuring distributions of coating thickness of drug delivery formulations - such as gels - applied for prophylaxis, contraception or therapy. The device consists of a rigid endoscope contained within a 27-mm-diam hollow, polished-transparent polycarbonate tube (150 mm long) with a hemispherical cap. Illumination is from a xenon arc. The device is inserted into, and remains stationary within the vagina. A custom gearing mechanism moves the endoscope relative to the tube, so that it views epithelial surfaces immediately apposing its outer surface (i.e., 150 mm long by 360 deg. azimuthal angle). Thus, with the tube fixed relative to the vagina, the endoscope sites local regions at distinct and measurable locations that span the vaginal epithelium. The returning light path is split between a video camera and photomultiplier. Excitation and emission filters in the light path enable measurement of fluorescence of the sited region. Thus, the instrument captures video images simultaneously with photometric measurement of fluorescence of each video field [∼10 mm diameter; formulations are labeled with 0.1% w/w United States Pharmacoepia (USP) injectable sodium fluorescein]. Position, time and fluorescence measurements are continuously displayed (on video) and recorded (to a computer database). The photomultiplier output is digitized to quantify fluorescence of the endoscope field of view. Quantification of the thickness of formulation coating of a surface sited by the device is achieved due to the linear relationship between thickness and fluorescence intensity for biologically relevant thin layers (of the order of 0.5 mm). Summary measures of coating have been developed, focusing upon extent, location and uniformity. The device has begun to be applied in human studies of model formulations for prophylaxis against infection with HIV and other sexually transmitted

  15. Abdominal fat thickness measurement using Focused Impedance Method (FIM) - phantom study

    Science.gov (United States)

    Haowlader, Salahuddin; Baig, Tanveer Noor; Siddique-e Rabbani, K.

    2010-04-01

    Abdominal fat thickness is a risk indicator of heart diseases, diabetes, etc., and its measurement is therefore important from the point of view of preventive care. Tetrapolar electrical impedance measurements (TPIM) could offer a simple and low cost alternative for such measurement compared to conventional techniques using CT scan and MRI, and has been tried by different groups. Focused Impedance Method (FIM) appears attractive as it can give localised information. An intuitive physical model was developed and experimental work was performed on a phantom designed to simulate abdominal subcutaneous fat layer in a body. TPIM measurements were performed with varying electrode separations. For small separations of current and potential electrodes, the measured impedance changed little, but started to decrease sharply beyond a certain separation, eventually diminishing gradually to negligible values. The finding could be explained using the intuitive physical model and gives an important practical information. TPIM and FIM may be useful for measurement of SFL thickness only if the electrode separations are within a certain specific range, and will fail to give reliable results if beyond this range. Further work, both analytical and experimental, are needed to establish this technique on a sound footing.

  16. Measurement of the thickness of the urethrovaginal space in women with or without vaginal orgasm.

    Science.gov (United States)

    Gravina, Giovanni Luca; Brandetti, Fulvia; Martini, Paolo; Carosa, Eleonora; Di Stasi, Savino M; Morano, Susanna; Lenzi, Andrea; Jannini, Emmanuele A

    2008-03-01

    The physiology and anatomy of female sexual function are poorly understood. The differences in sexual function among women may be partly attributed to anatomical factors. The purpose of this study was to use ultrasonography to evaluate the anatomical variability of the urethrovaginal space in women with and without vaginal orgasm. Twenty healthy, neurologically intact volunteers were recruited from a population of women who were a part of a previous published study. All women underwent a complete urodynamic evaluation and those with clinical and urodynamic urinary incontinence, idiopathic detrusor overactivity, or micturition disorders, as well as postmenopausal women and those with sexual dysfunction were excluded. The reported experience of vaginal orgasm was investigated. The urethrovaginal space thickness as measured by ultrasound was chosen as the indicator of urogenital anatomical variability. Designated evaluators carried out the measurements in a blinded fashion. The urethrovaginal space and distal, middle, and proximal urethrovaginal segments were thinner in women without vaginal orgasm. A direct correlation between the presence of vaginal orgasm and the thickness of urethrovaginal space was found. Women with a thicker urethrovaginal space were more likely to experience vaginal orgasm (r = 0.884; P = 0.015). A direct and significant correlation between the thickness of each urethrovaginal segment and the presence of vaginal orgasm was found, with the best correlation observed for the distal segment (r = 0.863; P orgasm.

  17. Comparison of central corneal thickness measurements with the galilei dual scheimpflug analyzer and ultrasound pachymetry

    International Nuclear Information System (INIS)

    Dildar, M.T.; Saeed, M.K.; Ali, S.; Yaqub, M.A.

    2017-01-01

    To determine the correlation between mean central corneal thickness taken with Galilei dual Scheimpflug Analyzer and Applanation Ultrasound Pachymetry. Study Design: Descriptive cross sectional study. Place and Duration of Study: Armed Forces Institute of Ophthalmology Rawalpindi, from Jul 2013 to Jan 2014. Material and Methods: Central corneal thickness was measured in 100 eyes of 50 patients. First three readings were taken with Galilei dual Scheimpflug analyzer, with a gap of 1 minute. Then three readings were taken with ultrasound pachymetry after applying topical 0.5% proparacaine (Alcain). The mean of the three readings was used for the analysis. Results: For right eye the mean central corneal thickness measured by the Galilei dual Scheimpflug analyzer and Ultrasound pachymetry was 544.06 mu m +- 27.36 and 546.88 +-m +- 27.71 respectively, and for left eye it was 544.72mu m +- 25.47 and 546.52+- m +- 26.15 respectively. There was a strong and positive correlation between the two instruments (r=0.969, p=0.000 for right eye and r=0.956, p=0.000 for left eye). Conclusions: The pachymetry readings with GSA showed strong and positive correlation with those of US pachymetry. So GSA may be considered as an alternative to US Pachymetry, thus avoiding operator-dependent errors, patient discomfort and other disadvantages. (author)

  18. Reproducibility of sonographic measurement of thickness and echogenicity of the plantar fascia.

    Science.gov (United States)

    Cheng, Ju-Wen; Tsai, Wen-Chung; Yu, Tung-Yang; Huang, Kuo-Yao

    2012-01-01

    To evaluate the intra- and interrater reliability of ultrasonographic measurements of the thickness and echogenicity of the plantar fascia. Eleven patients (20 feet), who complained of inferior heel pain, and 26 volunteers (52 feet) were enrolled. Two sonographers independently imaged the plantar fascia in both longitudinal and transverse planes. Volunteers were assessed twice to evaluate intrarater reliability. Quantitative evaluation of the echogenicity of the plantar fascia was performed by measuring the mean gray level of the region of interest using Digital Imaging and Communications in Medicine viewer software. Sonographic evaluation of the thickness of the plantar fascia showed high reliability. Sonographic evaluations of the presence or absence of hypoechoic change in the plantar fascia showed surprisingly low agreement. The reliability of gray-scale evaluations appears to be much better than subjective judgments in the evaluation of echogenicity. Transverse scanning did not show any advantage in sonographic evaluation of the plantar fascia. The reliability of sonographic examination of the thickness of the plantar fascia is high. Mean gray-level analysis of quantitative sonography can be used for the evaluation of echogenicity, which could reduce discrepancies in the interpretation of echogenicity by different sonographers. Longitudinal instead of transverse scanning is recommended for imaging the plantar fascia. Copyright © 2011 Wiley Periodicals, Inc.

  19. Scale Thickness Measurement of Steam Generator Tubing Using Eddy Current Signal of Bobbin Coil

    International Nuclear Information System (INIS)

    Kim, Chang Soo; Um, Ki Soo; Kim, Jae Dong

    2012-01-01

    Steam generator is one of the major components of nuclear power plant and steam generator tubes are the pressure boundary between primary and secondary side, which makes them critical for nuclear safety. As the operating time of nuclear power plant increases, not only damage mechanisms but also scaled deposits on steam generator tubes are known to be problematic causing tube support flow hole blockage and heat fouling. The ability to assess the extent and location of scaled deposits on tubes became essential for management and maintenance of steam generator and eddy current bobbin data can be utilized to measure thickness of scale on tubes. In this paper, tube reference standards with various thickness of scaled deposit has been set up to provide information about the overall deposit condition of steam generator tubes, providing essential tool for steam generator management and maintenance to predict and prevent future damages. Also, methodology to automatically measure scale thickness on tubes has been developed and applied to field data to estimate overall scale amount.

  20. Equations of bark thickness and volume profiles at different heights with easy-measurement variables

    Energy Technology Data Exchange (ETDEWEB)

    Cellini, J. M.; Galarza, M.; Burns, S. L.; Martinez-Pastur, G. J.; Lencinas, M. V.

    2012-11-01

    The objective of this work was to develop equations of thickness profile and bark volume at different heights with easy-measurement variables, taking as a study case Nothofagus pumilio forests, growing in different site qualities and growth phases in Southern Patagonia. Data was collected from 717 harvested trees. Three models were fitted using multiple, non-lineal regression and generalized linear model, by stepwise methodology, iteratively reweighted least squares method for maximum likelihood estimation and Marquardt algorithm. The dependent variables were diameter at 1.30 m height (DBH), relative height (RH) and growth phase (GP). The statistic evaluation was made through the adjusted determinant coefficient (r2-adj), standard error of the estimation (SEE), mean absolute error and residual analysis. All models presented good fitness with a significant correlation with the growth phase. A decrease in the thickness was observed when the relative height increase. Moreover, a bark coefficient was made to calculate volume with and without bark of individual trees, where significant differences according to site quality of the stands and DBH class of the trees were observed. It can be concluded that the prediction of bark thickness and bark coefficient is possible using DBH, height, site quality and growth phase, common and easy measurement variables used in forest inventories. (Author) 23 refs.

  1. Wall thickness measurements of tubes by Internal Rotary Inspection System (IRIS)- a comparative study with metallography

    International Nuclear Information System (INIS)

    Subramanian, C.V.; Joseph, A.; Ramesh, A.S.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    Internal Rotary Inspection System (IRIS) is a relatively new ultrasonic system of heat exchanger/ steam condenser tubes and pipelines for measurement of wall thinning and pitting due to corrosion. The wall thickness measurements made during a scan around the circumference of the tube are displayed as a stationary rectilinear display of circumferential cross section (Bscan) of the tube. The paper describes the results obtained on tubes of various materials used in process industries having corrosion on inner and outer surfaces of the tube. (author)

  2. Microprocessor isotope gauges for measurement of coating thickness and of air dust pollution

    International Nuclear Information System (INIS)

    Machaj, B.; Zrudelny, F.; Sikora, A.; Jaszczuk, J.

    1986-01-01

    The article describes a coating thickness gauge based on measurement of backscattered beta particles, and an air dust pollution gauge based on measurement of dust deposited from known volume of ambient air passed through a filter, by attenuation of beta radiation. In both cases to control the gauges and to process head signals microcomputer system based on Intel 8080 microprocessor is employed. Algorithms for processing and control of the gauges and corresponding flow charts are presented. Block diagram of microcomputer system used is presented, as well as the manner of operation of the gauges. (author)

  3. Finite grid radius and thickness effects on retarding potential analyzer measured suprathermal electron density and temperature

    International Nuclear Information System (INIS)

    Knudsen, W.C.

    1992-01-01

    The effect of finite grid radius and thickness on the electron current measured by planar retarding potential analyzers (RPAs) is analyzed numerically. Depending on the plasma environment, the current is significantly reduced below that which is calculated using a theoretical equation derived for an idealized RPA having grids with infinite radius and vanishingly small thickness. A correction factor to the idealized theoretical equation is derived for the Pioneer Venus (PV) orbiter RPA (ORPA) for electron gases consisting of one or more components obeying Maxwell statistics. The error in density and temperature of Maxwellian electron distributions previously derived from ORPA data using the theoretical expression for the idealized ORPA is evaluated by comparing the densities and temperatures derived from a sample of PV ORPA data using the theoretical expression with and without the correction factor

  4. Boundaries of dreams, boundaries of dreamers: thin and thick boundaries as a new personality measure.

    Science.gov (United States)

    Hartmann, E

    1989-11-01

    Previous work by the author and his collaborators on frequent nightmare sufferers demonstrated that these people had striking personality characteristics which could be called "thin boundaries" in a number of different senses. In order to measure thin and thick boundaries, a 145-item questionnaire, the Boundary Questionnaire, has been developed which has now been taken by over 1,000 persons. Preliminary results are presented indicating that, as predicted a priori, several new groups of nightmare sufferers and groups of art students scored usually "thin," whereas a group of naval officers had usually "thick" boundaries. Overall, thinness on the Boundary Questionnaire correlated highly positively (r = .40) with frequency of dream recall and also significantly (r = .16) with length of sleep.

  5. Measurement of thickness of thin films by the X-ray diffraction method

    International Nuclear Information System (INIS)

    Srinivasan, C.; Balasingh, C.; Singh, A.K.

    1979-07-01

    X-ray diffraction method can be used to measure the thickness of thin films (coatings). The principle and the experimental details of the x-ray diffraction methods are described. The intensities of the diffracted beams are derived assuming a random orientation of the crystallites in the diffracting medium. Consequently, the expressions are not valid when the sample has preferred orientation. To check the performance of the method, thicknesses of nickel deposits on mild steel plates were determined by the x-ray diffraction method and the results compared with those obtained by the weighing method and metallographic examination. The weighing method which gives an accuracy of +- 0.1 micron is taken as the standard. The x-ray diffraction methods and the metallographic examinations give values within +- 1 micron of the value obtained by the weighing method. (author)

  6. Apparent increase in the thickness of superconducting particles at low temperatures measured by electron holography.

    Science.gov (United States)

    Hirsch, J E

    2013-10-01

    We predict that superconducting particles will show an apparent increase in thickness at low temperatures when measured by electron holography. This will result not from a real thickness increase, rather from an increase in the mean inner potential sensed by the electron wave traveling through the particle, originating in expansion of the electronic wavefunction of the superconducting electrons and resulting negative charge expulsion from the interior to the surface of the superconductor, giving rise to an increase in the phase shift of the electron wavefront going through the sample relative to the wavefront going through vacuum. The temperature dependence of the observed phase shifts will yield valuable new information on the physics of the superconducting state of metals. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Choroidal thickness changes after dynamic exercise as measured by spectral-domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Nihat Sayin

    2015-01-01

    Full Text Available Purpose: To measure the choroidal thickness (CT after dynamic exercise by using enhanced depth imaging optical coherence tomography (EDI-OCT. Materials and Methods: A total of 19 healthy participants performed 10 min of low-impact, moderate-intensity exercise (i.e., riding a bicycle ergometer and were examined with EDI-OCT. Each participant was scanned before exercise and afterward at 5 min and 15 min. CT measurement was taken at the fovea and 1000 μ away from the fovea in the nasal, temporal, superior, and inferior regions. Retinal thickness, intraocular pressure, ocular perfusion pressure (OPP, heart rate, and mean blood pressure (mBP were also measured. Results: A significant increase occurred in OPP and mBP at 5 min and 15 min following exercise (P ˂ 0.05. The mean subfoveal CT at baseline was 344.00 ± 64.71 μm compared to 370.63 ± 66.87 μm at 5 min and 345.31 ± 63.58 μm at 15 min after exercise. CT measurements at all locations significantly increased at 5 min following exercise compared to the baseline (P ˂ 0.001, while measurements at 15 min following exercise did not significant differ compared to the baseline (P ˃ 0.05. There was no significant difference in retinal thickness at any location before and at 5 min and 15 min following exercise (P ˃ 0.05. Conclusion: Findings revealed that dynamic exercise causes a significant increase in CT for at least 5 min following exercise.

  8. Development of liquid film thickness measurement technique by high-density multipoint electrodes method

    International Nuclear Information System (INIS)

    Arai, Takahiro; Furuya, Masahiro; Kanai, Taizo

    2010-01-01

    High-density multipoint electrode method was developed to measure a liquid film thickness transient on a curved surface. The devised method allows us to measure spatial distribution of liquid film with its conductance between electrodes. The sensor was designed and fabricated as a multilayer print circuit board, where electrode pairs were distributed in reticular pattern with narrow interval. In order to measure a lot of electrode pairs at a high sampling rate, signal-processing method used by the wire mesh sensor measurement system was applied. An electrochemical impedance spectrometry concludes that the sampling rate of 1000 slices/s is feasible without signal distortion by electric double layer. The method was validated with two experimental campaigns: (1) a droplet impingement on a flat film and (2) a jet impingement on a rod-shape sensor surface. In the former experiment, a water droplet having 4 mm in diameter impinged onto the 1 mm thick film layer. A visual observation study with high-speed video camera shows after the liquid impingement, the water layer thinning process was clearly demonstrated with the sensor. For the latter experiment, the flexible circuit board was bended to form a cylindrical shape to measure water film on a simulated fuel rod in bundle geometry. A water jet having 3 mm in diameter impinged onto the rod-shape sensor surface. The process of wetting area enlargement on the rod surface was demonstrated in the same manner that the video-frames showed. (author)

  9. Macular Hole Progression after Intravitreal Bevacizumab for Hemicentral Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    Manish Nagpal

    2011-01-01

    Full Text Available Macular edema secondary to retinal vein occlusion is commonly being treated with off-label intravitreal bevacizumab with good outcomes. A significant reduction in macular edema and improvement in visual acuity is seen following such a treatment with no serious adverse effects. In the reported case, a full-thickness macular hole was noticed one month after intravitreal bevacizumab for macular edema secondary to hemicentral retinal vein occlusion. On a detailed review of the pre- and postoptical coherence tomography scans, it was realized that there was a preexisting stage 2-3 macular hole which was masked by the hemorrhages and edema at the fovea and the macular hole had progressed following the injection.

  10. Dynamic measurement of liquid film thickness in stratified flow by using ultrasonic echo technique

    International Nuclear Information System (INIS)

    Serizawa, A.; Nagane, K.; Kamei, T.; Kawara, Z.; Ebisu, T.; Torikoshi, K.

    2004-01-01

    We developed a technique to measure time-dependent local film thickness in stratified air-water flow over a horizontal plate by using a time of flight of ultrasonic transmission. The ultrasonic echoes reflected at the liquid/air interfaces are detected by a conventional ultrasonic instrumentation, and the signals are analyzed by a personal computer after being digitalized by an A/D converter to give the time of flight for the ultrasonic waves to run over a distance of twice of the film thickness. A 3.8 mm diameter probe type ultrasonic transducer was used in the present work which transmits and receives 10 MHz frequency ultrasonic waves. The estimated spatial resolution with this arrangement is 0.075 mm in film thickness for water. The time resolution, which depends on both the A/D converter and the memory capacity was up to several tens Hz. We also discussed the sensitivity of the method to the inclination angle of the interfaces. (author)

  11. Apparent increase in the thickness of superconducting particles at low temperatures measured by electron holography

    International Nuclear Information System (INIS)

    Hirsch, J.E.

    2013-01-01

    We predict that superconducting particles will show an apparent increase in thickness at low temperatures when measured by electron holography. This will result not from a real thickness increase, rather from an increase in the mean inner potential sensed by the electron wave traveling through the particle, originating in expansion of the electronic wavefunction of the superconducting electrons and resulting negative charge expulsion from the interior to the surface of the superconductor, giving rise to an increase in the phase shift of the electron wavefront going through the sample relative to the wavefront going through vacuum. The temperature dependence of the observed phase shifts will yield valuable new information on the physics of the superconducting state of metals. - Highlights: • A new property of superconducting particles is predicted. • Electron holography will show an apparent increase in thickness at low temperatures. • This will result from a predicted increase in the mean inner potential. • This will originate in expulsion of electrons from the interior to the surface. • This is not predicted by the conventional BCS theory of superconductivity

  12. The measurement of conductivity of copper indium disulphide thin films against temperature and thickness

    International Nuclear Information System (INIS)

    Yussof Wahab; Roslinda Zainal; Samsudi Sakrani

    1996-01-01

    Ternary semiconductor copper indium disulphide (CuInS sub 2) thin films have been prepared by thermal evaporation. Three stacked layers of film starting with copper, indium and finally sulphur was deposited on glass substrate in the thickness ratio of 1: 1: I0. The films were then annealed in carbon block by method known as encapsulated sulphurization at 350 degree C for 4 hours. The XRD analysis for four samples of thickness of 449.5, 586, 612 and 654 nm showed that stoichiometric CuInS sub 2, were formed at this annealing condition. The electrical conductivity of CuInS sub 2 thin films were measured against temperature from 150K to 300K. The conductivity values were between 76.6 Sm sup -1 to 631.26 Sm sup -1 and the result showed that it increase exponentially with temperature for the above temperature range. The resulting activation energies were found to be in the range 0.05 to 0.08 eV. This suggested that hopping mechanism predominant to the conducting process. It also found that the conductivity decreased with increasing film thickness

  13. European multicenter trial of the prevention of cystoid macular edema after cataract surgery in nondiabetics: ESCRS PREMED study report 1.

    Science.gov (United States)

    Wielders, Laura H P; Schouten, Jan S A G; Winkens, Bjorn; van den Biggelaar, Frank J H M; Veldhuizen, Claudette A; Findl, Oliver; Murta, Joaquim C N; Goslings, Willem R O; Tassignon, Marie-José; Joosse, Maurits V; Henry, Ype P; Rulo, Alexander H F; Güell, José L; Amon, Michael; Kohnen, Thomas; Nuijts, Rudy M M A

    2018-04-01

    To compare the efficacy of a topical nonsteroidal antiinflammatory drug, topical corticosteroid, and a combination of both drugs to prevent the occurrence of cystoid macular edema (CME) after cataract surgery in nondiabetic patients. Twelve European study centers. Randomized clinical trial. Nondiabetic patients having uneventful cataract surgery were included in this study. Patients were randomized to receive topical bromfenac 0.09% twice daily for 2 weeks or dexamethasone 0.1% 4 times daily with 1 drop less per day every following week, or a combination of both. The primary outcome was the difference in central subfield mean macular thickness 6 weeks postoperatively. Secondary outcome measures included corrected distance visual acuity as well as the incidence of CME and clinically significant macular edema (CSME) within 6 weeks and 12 weeks postoperatively. This study comprised 914 patients. Six weeks postoperatively, the central subfield mean macular thickness was 288.3 μm, 296.0 μm, and 284.5 μm in the bromfenac group, dexamethasone group, and combination treatment group, respectively (overall P = .006). The incidence of clinically significant macular edema within 12 weeks postoperatively was 3.6%, 5.1%, and 1.5%, respectively (overall P = .043). Patients treated with a combination of topical bromfenac 0.09% and dexamethasone 0.1% had a lower risk for developing CSME after cataract surgery than patients treated with a single drug. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Repeatability of Retinal Sensitivity Measurements Using a Medmont Dark-Adapted Chromatic Perimeter in Healthy and Age-Related Macular Degeneration Cases.

    Science.gov (United States)

    Tan, Rose S; Guymer, Robyn H; Luu, Chi D

    2018-05-01

    To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.

  15. Reliability of rehabilitative ultrasonographic imaging for muscle thickness measurement of the rhomboid major.

    Science.gov (United States)

    Jeong, Ju Ri; Ko, Young Jun; Ha, Hyun Geun; Lee, Wan Hee

    2016-03-01

    This study was to establish inter-rater and intrarater reliability of the rehabilitative ultrasonographic imaging (RUSI) technique for muscle thickness measurement of the rhomboid major at rest and with the shoulder abducted to 90°. Twenty-four young adults (eight men, 16 women; right-handed; mean age [±SD], 24·4 years [±2·6]) with no history of neck, shoulder, or arm pain were recruited. Rhomboid major muscle images were obtained in the resting position and with shoulder in 90° abduction using an ultrasonography system with a 7·5-MHz linear transducer. In these two positions, the examiners found the site at which the transducer could be placed. Two examiners obtained the images of all participants in three test sessions at random. Intraclass correlation coefficients (ICC) were used to estimate reliability. All ICCs (95% CI) were >0·75, ranging from 0·93 to 0·98, which indicates good reliability. The ICCs for inter-rater reliability ranged from 0·75 to 0·94. For the absolute value of the difference in the intra-examiner reliability between the right and left ratios, the ICCs ranged from 0·58 to 0·91. In this study, the intra- and interexaminer reliability of muscle thickness measurements of the rhomboid major were good. Therefore, we suggest that muscle thickness measurements of the rhomboid major obtained with the RUSI technique would be useful for clinical rehabilitative assessment. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  16. Thickness and roughness measurements for air-dried longleaf pine bark

    Science.gov (United States)

    Thomas L. Eberhardt

    2015-01-01

    Bark thicknesses for longleaf pine (Pinus palustris Mill.) were investigated using disks collected from trees harvested on a 70-year-old plantation. Maximum inner bark thickness was relatively constant along the tree bole whereas maximum outer bark thickness showed a definite decrease from the base of the tree to the top. The minimum whole bark thickness followed the...

  17. Measurement of through-thickness thermal diffusivity of thermoplastics using thermal wave method

    Science.gov (United States)

    Singh, R.; Mellinger, A.

    2015-04-01

    Thermo-physical properties, such as thermal conductivity, thermal diffusivity and specific heat are important quantities that are needed to interpret and characterize thermoplastic materials. Such characterization is necessary for many applications, ranging from aerospace engineering to food packaging, electrical and electronic industry and medical science. In this work, the thermal diffusivity of commercially available polymeric films is measured in the thickness direction at room temperature using thermal wave method. The results obtained with this method are in good agreement with theoretical and experimental values.

  18. In vivo sweat film layer thickness measured with Fourier-domain optical coherence tomography

    CSIR Research Space (South Africa)

    Jonathan, E

    2008-01-01

    Full Text Available s Centre form the f th s pr t fi d id Keywords: Fourier-domain optical coherence tomography; Human sweat secretion; Sweat gland; Sweat duct; Hyperhidrosis growing list of triggers include cancer, glucose control disorder, mental stress, social..., that is, the gland, duct and pore(s). However, due to a slow imaging time, COCT is largely restricted to morphometry of human tissue and thickness measurement of biologic and biologic samples [12,13]. ARTICLE IN PRESS Fourier-domain optical coherence...

  19. Observation of curative effect of intravitreal injection of conbercept in wet age-related macular degeneration: Optical coherence tomography analysis after injection.

    Science.gov (United States)

    Yang, Wen; Tan, Ying; Li, Chaowei; Liu, Yi; Lu, Guohua

    2018-04-01

    To observe the clinical efficacy of intravitreal injection of conbercept in the treatment of wet age-related macular degeneration (wAMD), optical coherence tomography (OCT) and the best corrected visual acuity (BCVA) was observed to measure the changes of anatomical changes of central macular thickness (CMT) and the area and volume of retinal pigment epithelium (RPE) uplift. Fifteen patients (15 eyes) with wet AMD were enrolled in this study. All patients underwent intravitreal injection of conbercept of 0.05 mL once. After 1 week, 1 month, and 3 months, OCT and BCVA were used to examine and to compare with the preoperative and postoperative central macular thickness and RPE uplift area. BCVA (median) increased respectively from 0.12 ± 0.13 to 0.21 ± 0.15 at 1 week, to 0.90 ± 0.25 at 1 month, to 0.38 ± 0.17 at 3 months (p macular decreased from 500 ± 25 μm to 256 ± 19 μm, 221 ± 29 μm, and 215 ± 14 μm, respectively. The normal physiological structure and stratification of the macular area were clear gradually. Conbercept treatment of wet AMD can significantly improve visual acuity, after 1 month up to the plateau, 3 months of continuous drug injection can make the vision maintained at a high stage, and macular retinal normal structural morphology recovery is good, the treatment has no obvious adverse reactions, and with good security. © 2018 Wiley Periodicals, Inc.

  20. Estudo macular na doença de Stargardt Macula study in Stargardt's disease

    Directory of Open Access Journals (Sweden)

    Otacílio de Oliveira Maia Júnior

    2008-02-01

    Full Text Available OBJETIVO: Avaliar dano estrutural macular na doença de Stargardt por meio da tomografia de coerência óptica, correlacionando-o com acuidade visual e duração da doença. MÉTODOS: Foram incluídos portadores da doença de Stargardt, submetidos à medida da acuidade visual (logMAR e exames complementares (retinografia, angiofluoresceinografia e tomografia de coerência óptica. Todos os casos foram reexaminados para confirmação diagnóstica, sendo determinada duração da doença. O grupo controle foi composto pelo mesmo número de casos, pareados por sexo, idade e sem qualquer alteração oftalmológica. RESULTADOS: A amostra foi composta por 22 pacientes (44 olhos, sendo 11 (50% do sexo masculino e 11 (50%, do feminino. A duração da doença variou de 3 a 21 anos (média de 11,4 ± 5,3 anos. Os grupos não apresentaram diferença significante na idade (p=0,98 e no sexo. O grupo caso apresentou valores de espessura macular na tomografia de coerência óptica significativamente menores em relação ao grupo controle (pPURPOSE: To evaluate de macular structural damage in Stargardt's disease by optical coherence tomography, correlating with visual acuity and disease duration. METHODS: Patients with Stargardt's disease were included and submitted to visual acuity (logMAR measurement and complementary examinations performed were color fundus photographs, fluorescein angiography and optical coherence tomography. All cases were reexamined for diagnostic confirmation and the duration of symptoms was determined. The control group was composed of the same number of subjects, matched by sex and age, without any ophthalmologic alteration. RESULTS: The sample was composed of 22 patients (44 eyes with Stargardt's disease, 11 (50% males and 11 (50% females. The duration of the disease varied from 3 to 21 years (mean of 11.4 ± 5.3 years. The groups did not show significant differences in age (p= 0.98 and sex. Concerning the macular thickness in optical

  1. R6 validation exercise: through thickness residual stress measurements on an experiment test vessel ring

    International Nuclear Information System (INIS)

    Mitchell, D.H.

    1988-06-01

    A series of bursting tests on thick-walled pressure vessels has been carried out as part of a validation exercise for the CEGB R6 failure assessment procedure. The objective of these tests was the examination of the behaviour of typical PWR primary vessel material subject to residual stresses in addition to primary loading with particular reference to the R6 assessment procedure. To this end, a semi-elliptic part-through defect was sited in the vessel longitudinal seam, which was a submerged arc weld in the non stress-relieved condition; it was then pressure tested to failure. Prior to the final assembly of this vessel, a ring of material was cut from it to act as a test-piece on which a residual stress survey could be made. Surface measurements using the centre-hole technique were made by CERL personnel, and this has been followed by two through- thickness measurements at BNL using the deep-hole technique. This paper describes these deep-hole measurements and presents the results from them. (author)

  2. Retrieval of subvisual cirrus cloud optical thickness from limb-scatter measurements

    Directory of Open Access Journals (Sweden)

    J. T. Wiensz

    2013-01-01

    Full Text Available We present a technique for estimating the optical thickness of subvisual cirrus clouds detected by OSIRIS (Optical Spectrograph and Infrared Imaging System, a limb-viewing satellite instrument that measures scattered radiances from the UV to the near-IR. The measurement set is composed of a ratio of limb radiance profiles at two wavelengths that indicates the presence of cloud-scattering regions. Cross-sections and phase functions from an in situ database are used to simulate scattering by cloud-particles. With appropriate configurations discussed in this paper, the SASKTRAN successive-orders of scatter radiative transfer model is able to simulate accurately the in-cloud radiances from OSIRIS. Configured in this way, the model is used with a multiplicative algebraic reconstruction technique (MART to retrieve the cloud extinction profile for an assumed effective cloud particle size. The sensitivity of these retrievals to key auxiliary model parameters is shown, and it is shown that the retrieved extinction profile, for an assumed effective cloud particle size, models well the measured in-cloud radiances from OSIRIS. The greatest sensitivity of the retrieved optical thickness is to the effective cloud particle size. Since OSIRIS has an 11-yr record of subvisual cirrus cloud detections, the work described in this manuscript provides a very useful method for providing a long-term global record of the properties of these clouds.

  3. The measurement of layer thickness by the deconvolution of ultrasonic signals

    International Nuclear Information System (INIS)

    McIntyre, P.J.

    1977-07-01

    An ultrasonic technique for measuring layer thickness, such as oxide on corroded steel, is described. A time domain response function is extracted from an ultrasonic signal reflected from the layered system. This signal is the convolution of the input signal with the response function of the layer. By using a signal reflected from a non-layered surface to represent the input, the response function may be obtained by deconvolution. The advantage of this technique over that described by Haines and Bel (1975) is that the quality of the results obtained using their method depends on the ability of a skilled operator in lining up an arbitrary common feature of the signals received. Using deconvolution no operator manipulations are necessary and so less highly trained personnel may successfully make the measurements. Results are presented for layers of araldite on aluminium and magnetite of steel. The results agreed satisfactorily with predictions but in the case of magnetite, its high velocity of sound meant that thicknesses of less than 250 microns were difficult to measure accurately. (author)

  4. Effects of X-ray tube parameters on thickness measure precision in X-ray profile gauge

    International Nuclear Information System (INIS)

    Miao Jichen; Wu Zhifang; Xing Guilai

    2011-01-01

    Instantaneous profile gauge technology has been widely used in metallurgy industry because it can on-line get the profile of steel strip. It has characters of high measure precision and wide measure range, but the X-ray tube parameters only can be set few different values during measurement. The relations of thickness measure precision and X-ray tube current, X-ray tube voltage were analyzed. The results show that the X-ray tube current affects the thickness measure precision and the X-ray tube voltage determines the thickness measure range. The method of estimating the X-ray current by thickness measure precision was provided in the end. This method is the base of X-ray source selection and X-ray source parameter's setting in the instantaneous profile gauge. (authors)

  5. Uncertainty evaluation of thickness and warp of a silicon wafer measured by a spectrally resolved interferometer

    Science.gov (United States)

    Praba Drijarkara, Agustinus; Gergiso Gebrie, Tadesse; Lee, Jae Yong; Kang, Chu-Shik

    2018-06-01

    Evaluation of uncertainty of thickness and gravity-compensated warp of a silicon wafer measured by a spectrally resolved interferometer is presented. The evaluation is performed in a rigorous manner, by analysing the propagation of uncertainty from the input quantities through all the steps of measurement functions, in accordance with the ISO Guide to the Expression of Uncertainty in Measurement. In the evaluation, correlation between input quantities as well as uncertainty attributed to thermal effect, which were not included in earlier publications, are taken into account. The temperature dependence of the group refractive index of silicon was found to be nonlinear and varies widely within a wafer and also between different wafers. The uncertainty evaluation described here can be applied to other spectral interferometry applications based on similar principles.

  6. Serous Macular Detachments

    Directory of Open Access Journals (Sweden)

    Hakan Özdemir

    2012-03-01

    Full Text Available Serous macular detachment has only recently been recognized to occur in a significant number of eyes with macular pathology including diabetic retinopathy, retinal vein occlusion, Behçet disease, Irvine-Gass syndrome and pars planitis. These serous retinal detachments associated with retinal vascular leakage are not suspected clinically or angiographically but can be diagnosed with optical coherence tomography (OCT beneath the edematous neurosensory retina. The detection of shallow foveal detachment may be helpful in better understanding the pathogenesis of these disorders. In addition, the detection of serous macular detachment may also help to better guide and assess the results of therapy in the future. (Turk J Oph thal mol 2012; 42: 146-9

  7. Air-coupled ultrasonic through-transmission thickness measurements of steel plates.

    Science.gov (United States)

    Waag, Grunde; Hoff, Lars; Norli, Petter

    2015-02-01

    Non-destructive ultrasonic testing of steel structures provide valuable information in e.g. inspection of pipes, ships and offshore structures. In many practical applications, contact measurements are cumbersome or not possible, and air-coupled ultrasound can provide a solution. This paper presents air-coupled ultrasonic through-transmission measurements on a steel plate with thicknesses 10.15 mm; 10.0 mm; 9.8 mm. Ultrasound pulses were transmitted from a piezoelectric transducer at normal incidence, through the steel plate, and were received at the opposite side. The S1, A2 and A3 modes of the plate are excited, with resonance frequencies that depend on the material properties and the thickness of the plate. The results show that the resonances could be clearly identified after transmission through the steel plate, and that the frequencies of the resonances could be used to distinguish between the three plate thicknesses. The S1-mode resonance was observed to be shifted 10% down compared to a simple plane wave half-wave resonance model, while the A2 and S2 modes were found approximately at the corresponding plane-wave resonance frequencies. A model based on the angular spectrum method was used to predict the response of the through-transmission setup. This model included the finite aperture of the transmitter and receiver, and compressional and shear waves in the solid. The model predicts the frequencies of the observed modes of the plate to within 1%, including the down-shift of the S1-mode. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Clinical experience with fixed bimonthly aflibercept dosing in treatment-experienced patients with neovascular age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Khanani AM

    2015-07-01

    Full Text Available Arshad M Khanani Sierra Eye Associates, Reno, NV, USA Purpose: To evaluate the durability of fixed bimonthly dosing of intravitreal aflibercept for neovascular age-related macular degeneration.Methods: Records of 16 patients were retrospectively reviewed. Patients received three initial 2.0 mg monthly doses of aflibercept then 8-weekly doses according to the product label. Best-corrected visual acuity (Early Treatment Diabetic Retinopathy Study [ETDRS] letters, central macular thickness, fluid on optical coherence tomography, and pigment epithelial detachment (PED were measured.Results: Prior to starting aflibercept, 13 patients had subretinal fluid (SRF, five had intraretinal fluid (IRF, four had PED, and baseline visual acuity (VA was 62 approximate ETDRS letters. Following the monthly dosing, seven patients had no improvement or decreased VA, ten patients still had SRF/IRF, and PED had worsened in one patient. At Visit 4, an average of 6.8 weeks after Visit 3, VA had decreased in seven patients, SRF/IRF had increased in 12 patients, and PED had returned in all patients who initially responded. Based on the presence of fluid after the initial monthly injections, 12 patients could not be extended to fixed bimonthly dosing.Conclusion: This case series adds to the growing body of evidence on the need for flexible dosing schedules for the personalized treatment of neovascular age-related macular degeneration. Keywords: age-related macular degeneration, AMD, bimonthly, regimen, aflibercept, case studies, retinal fluid

  9. Measurements of diffusive sublayer thicknesses in the ocean by alabaster dissolution, and their implications for the measurements of benthic fluxes

    Science.gov (United States)

    Santschi, Peter H.; Anderson, Robert F.; Fleisher, Martin Q.; Bowles, Walter

    1991-06-01

    Fluxes of reactive chemical species across the sediment-water interface can profoundly influence the dominant biogeochemical cycles in the worlds ocean. However, reliable in-situ measurements of benthic fluxes of many reactive species cannot be carried out without adjustment of stirring rates inside benthic flux chambers to match boundary layer conditions prevailing outside. A simple method to compare flow levels consists of measurements of gypsum dissolution rates inside benthic chambers and on the seafloor. The measurement of the diffusion-controlled dissolution rate of gypsum allows the estimation of the diffusive sublayer thickness and the time-averaged bottom stress on the seafloor. This method had previously been intercalibrated with the stress sensor method in flumes and inside benthic chambers. We describe here free-vehicle deployments of alabaster plates on the bottom of the ocean which gave results consistent with hydrodynamic theory. Errors in the calculated diffusive sublayer thicknesses were estimated to be about 10-15% for typical deployment conditions in the ocean. Current velocities 5 m off the bottom, which were measured concurrently during two deployments, allowed for comparisons with hydrodynamic predictions of diffusive sublayer thicknesses. The values obtained this way agreed within 15%. The measured mass transfer velocity was found to correlate with the plate dimension L, to the power of ⅓. This confirms the theoretical procedure for extrapolating to infinite plate size when calculating the sublayer impedance of solute fluxes from sediments (where L is large). Typical values of diffusive sublayer thicknesses, corrected to infinite plate size, were 1200 μm for current velocities, U100, of 2 cm s-1, and 500 μm at 8 cm s-1. Furthermore, values of friction velocities calculated from alabaster dissolution were compared with those using stress sensors. Gypsum plate values of u* were 0 and 30% lower than skin friction values of u*, at u* values

  10. Central Corneal Thickness Measurements in Nonarteritic Anterior Ischemic Optic Neuropathy Patients: A Controlled Study

    Science.gov (United States)

    Jabaly-Habib, Haneen; Naftali, Modi; Habib, George

    2014-01-01

    Purpose. To measure central corneal thickness (CCT) in patients with history of nonarteritic anterior ischemic optic neuropathy (NAION). Patients and Methods. Patients older than 40 years with a history of NAION (group 1) were prospectively evaluated including full eye examination and central corneal thickness (CCT) pachymetry. Patients with a history of intraocular surgery, corneal disease, glaucoma, and contact lens wear were excluded. Measurements were also performed in a gender and age matched control group (group 2). Results. Thirty-one eyes of 31 NAION patients in group 1 were included and 30 eyes of 30 participants in group 2. There were 15 men in group 1 and 9 in group 2 (P = 0.141), and mean age of the patients was 59 ± 10 years in group 1 versus 61 ± 11 years in group 2 (P = 0.708). Mean CCT was 539 ± 30 microns in group 1 and 550 ± 33 microns in group 2 (P = 0.155). Conclusion. Patients with NAION have no special characteristic of CCT in contrast to the crowded optic disc known to be a significant anatomic risk factor for NAION. More studies should be carried out to investigate CCT and other structure related elements in NAION patients. PMID:24804080

  11. Prototype gauge for measuring contour and wall thicknesses of hemispherical parts

    International Nuclear Information System (INIS)

    Aarts, H.J.; Robertson, J.H.

    1976-01-01

    A prototype gauge (gage) was designed and fabricated using air bearings in a new configuration to provide less error and distortion during inspection of hemispherical parts. No wear occurs on the moving parts during operations and accuracy of alignment is maintained. The gauge will check outside radial distance, inside radial, and outside radial and wall, and inner radial and wall thicknesses of parts. The gauge contains only four moving parts, which increases the measuring accuracy. A horizontal table rotates. A table mounted on the horizontal table at 45 0 rotates through two transducers. All moving parts are mounted on hydrostatic gas bearings. Laser interferometric, air-bearing gauge heads are used to obtain the required data. Investigation of a hemispherical part is in any desired spiral path from equator to pole. Measurement information is obtained from two laser interferometric transducers using linear air bearings. The transducers use a Spectra Physics Model-120 helium and neon laser. Working range of each transducer is 1.5 inches. The fringe voltage signals are amplified and converted to inches to be displayed on a digital readout. A punched paper tape contains the nominal inside diameter (ID) and outside diameter (OD) information in Binary Coded Decimal form. The tape is fed into a digital computer which calculates error information on ID, OD, and wall thickness. This information is converted to analog form and displayed simultaneously on a strip-chart recorder

  12. LOGISMOS-B for primates: primate cortical surface reconstruction and thickness measurement

    Science.gov (United States)

    Oguz, Ipek; Styner, Martin; Sanchez, Mar; Shi, Yundi; Sonka, Milan

    2015-03-01

    Cortical thickness and surface area are important morphological measures with implications for many psychiatric and neurological conditions. Automated segmentation and reconstruction of the cortical surface from 3D MRI scans is challenging due to the variable anatomy of the cortex and its highly complex geometry. While many methods exist for this task in the context of the human brain, these methods are typically not readily applicable to the primate brain. We propose an innovative approach based on our recently proposed human cortical reconstruction algorithm, LOGISMOS-B, and the Laplace-based thickness measurement method. Quantitative evaluation of our approach was performed based on a dataset of T1- and T2-weighted MRI scans from 12-month-old macaques where labeling by our anatomical experts was used as independent standard. In this dataset, LOGISMOS-B has an average signed surface error of 0.01 +/- 0.03mm and an unsigned surface error of 0.42 +/- 0.03mm over the whole brain. Excluding the rather problematic temporal pole region further improves unsigned surface distance to 0.34 +/- 0.03mm. This high level of accuracy reached by our algorithm even in this challenging developmental dataset illustrates its robustness and its potential for primate brain studies.

  13. Thickness measurement of SiO2 films thinner than 1 nm by X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Joong Kim, Kyung; Park, Ki Tae; Lee, Jong Wan

    2006-01-01

    The thickness measurement of ultra-thin SiO 2 films thinner than 1 nm was studied by X-ray photoelectron spectroscopy (XPS). Amorphous SiO 2 thin films were grown on amorphous Si films to avoid the thickness difference due to the crystalline structure of a substrate. SiO 2 thin films were grown by ion beam sputter deposition under oxygen gas flow and the thickness was measured by in situ XPS. The attenuation length was determined experimentally by a SiO 2 film with a known thickness. The straight line fit between the measured thickness using XPS and the nominal thickness showed a good linear relation with a gradient of 0.969 and a small offset of 0.126 nm. The gradient measured at the range of 3.4-0.28 nm was very close to that measured at sub-nanometer range of 1.13-0.28 nm. This result means that the reliable measurement of SiO 2 film thickness below 1 nm is possible by XPS

  14. Confiabilidade da medida de espessuras musculares pela ultrassonografia Reliability of muscle thickness measurements using ultrasound

    Directory of Open Access Journals (Sweden)

    Paulo Sergio Chagas Gomes

    2010-02-01

    Full Text Available OBJETIVO: Determinar a confiabilidade das medidas de espessuras dos músculos flexores e extensores do cotovelo e joelho pela ultrassonografia (US, quantificando o erro típico associado a essas medidas (ETM. MÉTODOS: A confiabilidade (duas medidas interdias foi determinada em 15 voluntários aparentemente saudáveis (oito mulheres, 33,9 ± 11,4 anos, 76 ± 21kg, 170 ± 10cm. As imagens da musculatura flexora (FC e extensora do cotovelo (EC e flexora (FJ e extensora do joelho (EJ foram obtidas pela US bidimensional no modo B, utilizando transdutor de 7,5MHz. As espessuras do tecido muscular compreendidas entre as interfaces com o osso e com o tecido adiposo foram medidas em sítios anatômicos identificados e registrados para ser repetidos na segunda medida. RESULTADOS: A ANOVA não identificou diferenças significativas entre as medidas repetidas. Os coeficientes de correlação intraclasse foram FC = 0,970, EC = 0,971, FJ = 0,555 e EJ = 0,929 (P PURPOSE: To determine the reliability of muscle thickness measurements of elbow and knee flexors and extensors using ultrasound, and to quantify the typical error associated to the measurements (TEM. METHODS: The test-retest reliability was determined in 15 apparently healthy volunteers (8 women, 34 ± 11 years, 76 ± 21 kg, 170 ± 10 cm. The images of elbow flexors (EF and extensors (EE and knee flexors (KF and extensors (KE were obtained using a two dimensional mode B ultrasound instrument with a 7.5 MHz transducer. Muscle thickness between the adipose tissue and bone interfaces were measured at anatomical landmarks previously identified and recorded to assure the exact site for the retest. RESULTS: ANOVA did not identify any significant differences between the repeated measurements. Intraclass correlation coefficients (ICC of each pair of measure were EF = 0.970, EE = 0.971, KF = 0.555 e KE = 0.929 (P < 0.05 for all. The coefficients of variation were 3.9 %, 6.1 %, 6.6 % e 4.6 %, and TEM 1.3 mm, 1

  15. Instrument for thickness measuring of a workpiece with the help of ultrasonic waves

    International Nuclear Information System (INIS)

    Wells, F.H.; Martin, R.

    1978-01-01

    The proposed ultrasonic measuring instrument has a generator for pulsed ultrasonic signals, a detector as well as a contact arrangement that connects both with the work piece. The transportation lag of the signals through the contact arrangements amounts to at least five times the transportation lag of the signals due to the thickness of a work piece. Furthermore there is an arrangement for the measurement of the delay between two successive echos from the back of the work piece with the help of a zero passage detector for the generation of a time-reference value on each echo signal. This permits an exact time control of the pulses which range in the field around nano seconds. The instrument is explained with 8 drawings and a detailed description. (RW) [de

  16. Multiple extrafoveal macular holes following internal limiting membrane peeling

    Directory of Open Access Journals (Sweden)

    Hussain N

    2018-05-01

    Full Text Available Nazimul Hussain, Sandip Mitra Department of Ophthalmology, Al Zahra Hospital, Sharjah, United Arab Emirates Objective: Internal limiting membrane (ILM peeling has been the standard of treatment for macular holes. Besides, causing retinal nerve fiber layer surface abnormality, postoperative extrafoveal multiple retinal holes is a rare phenomenon following ILM peeling. We report an unusual complication of eight extrafoveal macular holes occurring following ILM peeling.Case presentation: A 60-year-old male presented with complaints of decreased and distorted vision in the right eye. He was diagnosed as having epiretinal membrane with lamellar macular hole. He underwent 23G pars plana vitrectomy, brilliant blue assisted ILM peeling and fluid gas exchange. Intraoperatively, ILM was found to be adherent to the underlying neurosensory retina. One month after cataract surgery, he underwent YAG capsulotomy in the right eye. He complained of visual distortion. His fundus evaluation in the right eye showed multiple (eight extrafoveal retinal holes temporal to the macula clustered together.Conclusion: This case demonstrated that peeling of ILM, especially when it is adherent to the underlying neurosensory retina, may cause unwanted mechanical trauma to the inner retina. Glial apoptosis and neuronal degeneration may presumably play a role in delayed appearance of multiple (eight extrafoveal macular holes, which has not been reported earlier. Keywords: internal limiting membrane, lamellar macular hole, full thickness macular holes, epiretinal membrane

  17. Efficacy of intravitreal ranibizumab injection combined with macular grid photocoagulation for diabetic macular edema

    Directory of Open Access Journals (Sweden)

    Hu-Lin Jiang

    2014-07-01

    Full Text Available AIM:To evaluate the clinical efficacy of intravitreal injection of ranibizumab combined with macular grid photocoagulation for diabetic macular edema(DME.METHODS:Totally 60 eyes(60 patientswith DME were randomly divided into 2 groups: 30 eyes of simple injection group underwent intravitreal injection of ranibizumab, and 30 eyes of combined treatment group underwent intravitreal injection of ranibizumab and macular grid photocoagulation 1wk later. The best corrected visual acuity(BCVA, central macular thickness(CMTmeasured by optical coherence tomography(OCTand postoperative complications were observed.RESULTS:In simple injection group, the BCVA after operation were separately 0.390±0.075(4wk, 0.367±0.088(8wkand 0.319±0.064(12wk,the CMT after operation were separately 221.63±112.34μm(4wk, 337.73±99.56μm(8wkand 432.92±100.46μm(12wk, which were much better than pre-operation. But during follow-up, the BCVA presented down trend and the CMT was on the rise slowly. In combined treatment group, the BCVA after operation were separately 0.385±0.036(4wk, 0.382±0.079(8wkand 0.377±0.097(12wk,the CMT after operation were separately 249.77±106.55μm(4wk, 270.40±92.88μm(8wkand 275.84±97.34μm(12wk, which were satisfactory and steady during follow-up, better than simple injection group(PCONCLUSION:Intravitreal injection of ranibizumab can effectively improve visual acuity and decrease central foveal thickness for patients with DME, combining with macular grid photocoagulation can ensure therapeutic effects steady and permanent.

  18. Autologous transplantation of the internal limiting membrane for refractory macular holes.

    Science.gov (United States)

    Morizane, Yuki; Shiraga, Fumio; Kimura, Shuhei; Hosokawa, Mio; Shiode, Yusuke; Kawata, Tetsuhiro; Hosogi, Mika; Shirakata, Yukari; Okanouchi, Toshio

    2014-04-01

    To determine the effectiveness of autologous transplantation of the internal limiting membrane (ILM) for refractory macular holes. Prospective, interventional case series. Ten eyes of 10 consecutive patients who underwent autologous transplantation of the ILM for the treatment of refractory macular holes were studied. The primary diseases in these patients were large idiopathic macular holes that had existed for more than 1 year (4 eyes), a traumatic macular hole (1 eye), myopic foveoschisis (2 eyes), foveoschisis resulting from pit-macular syndrome (2 eyes), and proliferative diabetic retinopathy (1 eye). Apart from the 5 eyes with idiopathic or traumatic macular holes, macular holes developed in the other 5 eyes after initial vitrectomies with ILM removal. In all eyes, regular macular hole surgery failed to achieve closure. The main outcome measures used in this study were macular hole closure and best-corrected visual acuity (BCVA). Macular holes were closed successfully in 9 eyes (90%) after autologous transplantation of the ILM. The postoperative BCVAs were significantly better than the preoperative BCVAs (P = .007, paired t test). Postoperative BCVAs improved by more than 0.2 logarithm of the minimal angle of resolution units in 8 eyes (80%) and were unchanged in 2 eyes (20%). Although this is a pilot study, the results suggest that autologous transplantation of the ILM may contribute to improved anatomic and visual outcomes in the treatment of refractory macular holes and may warrant further investigation. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. What Is Age-Related Macular Degeneration?

    Science.gov (United States)

    ... Eye Health / Eye Health A-Z Age-Related Macular Degeneration Sections What Is Macular Degeneration? How is AMD ... What Does Macular Degeneration Look Like? What Is Macular Degeneration? Leer en Español: ¿Qué es la degeneración macular ...

  20. Film thickness measurement based on nonlinear phase analysis using a Linnik microscopic white-light spectral interferometer.

    Science.gov (United States)

    Guo, Tong; Chen, Zhuo; Li, Minghui; Wu, Juhong; Fu, Xing; Hu, Xiaotang

    2018-04-20

    Based on white-light spectral interferometry and the Linnik microscopic interference configuration, the nonlinear phase components of the spectral interferometric signal were analyzed for film thickness measurement. The spectral interferometric signal was obtained using a Linnik microscopic white-light spectral interferometer, which includes the nonlinear phase components associated with the effective thickness, the nonlinear phase error caused by the double-objective lens, and the nonlinear phase of the thin film itself. To determine the influence of the effective thickness, a wavelength-correction method was proposed that converts the effective thickness into a constant value; the nonlinear phase caused by the effective thickness can then be determined and subtracted from the total nonlinear phase. A method for the extraction of the nonlinear phase error caused by the double-objective lens was also proposed. Accurate thickness measurement of a thin film can be achieved by fitting the nonlinear phase of the thin film after removal of the nonlinear phase caused by the effective thickness and by the nonlinear phase error caused by the double-objective lens. The experimental results demonstrated that both the wavelength-correction method and the extraction method for the nonlinear phase error caused by the double-objective lens improve the accuracy of film thickness measurements.

  1. Influence of corneal thickness on comparative intraocular pressure measurements with Goldmann and non-contact tonometers in keratoconus.

    Science.gov (United States)

    Stabuc Silih, Mirna; Hawlina, Marko

    2003-12-01

    The influence of corneal thickness and curvature on the difference between intraocular pressure (IOP) measurements obtained with non-contact (NCT) and those with the Goldmann applanation tonometer (GAT) was studied in patients with keratoconus. We examined 113 patients with keratoconus. IOP was measured by the Canon TX 10 non-contact tonometer and the Goldmann tonometer, corneal curvature and thickness were obtained by Humphrey Automatic Refractometer Keratometer and Orbscan Version 3.0 Bausch & Lomb Surgical. The IOP measured by NCT was significantly lower than that measured by GAT. The mean pachymetry of the thinnest point was 423.15 +/- 98.43 microm for the right eyes and 426.7 +/- 93.88 microm for the left eyes. The difference between NCT-GAT and corneal thickness showed a significant negative correlation (r = - 0.427, p < 0.0001; t = - 3.677, p < 0.0001). Values of NCT measurements were significantly increasing with corneal thickness (F = 6.505, p < 0.0001 for right eyes and F = 4.37, p = 0.004 for left eyes), whilst GAT measurements did not show a significant influence of the corneal thickness. The keratometry had no effect on the difference between NCT-GAT measurements (t = 1.090, p = 0.278). The thin cornea has more influence on the measurement with NCT than GAT. The relative precision of NCT compared with GAT seems to be influenced by the corneal thickness.

  2. SNOW THICKNESS ON AUSTRE GRØNFJORDBREEN, SVALBARD, FROM RADAR MEASUREMENTS AND STANDARD SNOW SURVEYS

    Directory of Open Access Journals (Sweden)

    I. I. Lavrentiev

    2018-01-01

    Full Text Available Summary Comparison of two methods of measurements of snow cover thickness on the glacier Austre Grønfjordbreen, Svalbard was performed in the spring of 2014. These methods were the radar (500 MHz observations and standard snow surveys. Measurements were conducted in 77 different points on the surface of the glacier. A good correlation (R2 = 0.98 was revealed. In comparison with the data of snow surveys, the radar measurements show a similar but more detailed pattern of the distribution of the snow cover depth. The discrepancy between the depths of snow cover on maps plotted from data of both methods did not exceed 30 cm in most parts of the glacier. The standard error of interpolation of the radar data onto the entire glacier surface amounts, on average, to 18 cm. This corresponds to the error of radar measurements of 18.8% when an average snow depth is about 160 cm and 9.4% at its maximum thickness of 320 cm. The distance between the measurement points at which the spatial covariance of the snow depth disappears falls between 236 and 283 m along the glacier, and between 117 and 165 m across its position. We compared the results of radar measurements of the pulse-delay time of reflections from the base of the snow cover with the data of manual probe measurements at 10 points and direct measurements of snow depth and average density in 12 snow pits. The average speed of radio waves propagation in the snow was determined as Vcr = 23.4±0.2 cm ns−1. This magnitude and the Looyenga and Kovacs formulas allowed estimating the average density of snow cover ρL = 353.1±13.1 kg m−3 and ρK = 337.4±12.9 kg m−3. The difference from average density measured in 12 pits ρav.meas = 387.4±12.9 kg m−3 amounts to −10.8% and −14.8%. In 2014, according to snow and radar measurements, altitudinal gradient of snow accumulation on the glacier Austre Grønfjordbreen was equal to 0.21 m/100 m, which is smaller than the

  3. Geophysical surveying in the Sacramento Delta for earthquake hazard assessment and measurement of peat thickness

    Science.gov (United States)

    Craig, M. S.; Kundariya, N.; Hayashi, K.; Srinivas, A.; Burnham, M.; Oikawa, P.

    2017-12-01

    Near surface geophysical surveys were conducted in the Sacramento-San Joaquin Delta for earthquake hazard assessment and to provide estimates of peat thickness for use in carbon models. Delta islands have experienced 3-8 meters of subsidence during the past century due to oxidation and compaction of peat. Projected sea level rise over the next century will contribute to an ongoing landward shift of the freshwater-saltwater interface, and increase the risk of flooding due to levee failure or overtopping. Seismic shear wave velocity (VS) was measured in the upper 30 meters to determine Uniform Building Code (UBC)/ National Earthquake Hazard Reduction Program (NEHRP) site class. Both seismic and ground penetrating radar (GPR) methods were employed to estimate peat thickness. Seismic surface wave surveys were conducted at eight sites on three islands and GPR surveys were conducted at two of the sites. Combined with sites surveyed in 2015, the new work brings the total number of sites surveyed in the Delta to twenty.Soil boreholes were made at several locations using a hand auger, and peat thickness ranged from 2.1 to 5.5 meters. Seismic surveys were conducted using the multichannel analysis of surface wave (MASW) method and the microtremor array method (MAM). On Bouldin Island, VS of the surficial peat layer was 32 m/s at a site with pure peat and 63 m/s at a site peat with higher clay and silt content. Velocities at these sites reached a similar value, about 125 m/s, at a depth of 10 m. GPR surveys were performed at two sites on Sherman Island using 100 MHz antennas, and indicated the base of the peat layer at a depth of about 4 meters, consistent with nearby auger holes.The results of this work include VS depth profiles and UBC/NEHRP site classifications. Seismic and GPR methods may be used in a complementary fashion to estimate peat thickness. The seismic surface wave method is a relatively robust method and more effective than GPR in many areas with high clay

  4. Fracture toughness of silicon nitride thin films of different thicknesses as measured by bulge tests

    International Nuclear Information System (INIS)

    Merle, B.; Goeken, M.

    2011-01-01

    A bulge test setup was used to determine the fracture toughness of amorphous low-pressure chemical vapor deposited (LPCVD) silicon nitride films with various thicknesses in the range 40-108 nm. A crack-like slit was milled in the center of each free-standing film with a focused ion beam, and the membrane was deformed in the bulge test until failure occurred. The fracture toughness K IC was calculated from the pre-crack length and the stress at failure. It is shown that the membrane is in a transition state between pure plane-stress and plane-strain which, however, had a negligible influence on the measurement of the fracture toughness, because of the high brittleness of silicon nitride and its low Young's modulus over yield strength ratio. The fracture toughness K IC was found to be constant at 6.3 ± 0.4 MPa m 1/2 over the whole thickness range studied, which compares well with bulk values. This means that the fracture toughness, like the Young's modulus, is a size-independent quantity for LPCVD silicon nitride. This presumably holds true for all amorphous brittle ceramic materials.

  5. Measurement of neutron yield by 62 MeV proton beam on a thick beryllium target

    Energy Technology Data Exchange (ETDEWEB)

    Osipenko, M., E-mail: osipenko@ge.infn.it [INFN, sezione di Genova, 16146 Genova (Italy); Ripani, M. [INFN, sezione di Genova, 16146 Genova (Italy); Alba, R. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Ricco, G. [INFN, sezione di Genova, 16146 Genova (Italy); Schillaci, M. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Barbagallo, M. [INFN, sezione di Bari, 70126 Bari (Italy); Boccaccio, P. [INFN, Laboratori Nazionali di Legnaro, 35020 Legnaro (Italy); Celentano, A. [Dipartimento di Fisica dell' Università di Genova, 16146 Genova (Italy); Colonna, N. [INFN, sezione di Bari, 70126 Bari (Italy); Cosentino, L.; Del Zoppo, A.; Di Pietro, A. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Esposito, J. [INFN, Laboratori Nazionali di Legnaro, 35020 Legnaro (Italy); Figuera, P.; Finocchiaro, P. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Kostyukov, A. [Moscow State University, Moscow 119992 (Russian Federation); Maiolino, C.; Santonocito, D.; Scuderi, V. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Viberti, C.M. [Dipartimento di Fisica dell' Università di Genova, 16146 Genova (Italy)

    2013-09-21

    The design of a low-power prototype of neutron amplifier recently proposed within the INFN-E project indicated the need for more accurate data on the neutron yield produced by a proton beam with energy of about 70 MeV impinging on a thick beryllium target. Such measurement was performed at the LNS superconducting cyclotron, covering a wide angular range from 0° to 150° and a complete neutron energy interval from thermal to beam energy. Neutrons with energy above 0.5 MeV were measured by liquid scintillators exploiting their time of flight to determine the kinetic energy. For lower energy neutrons, down to thermal energy, a {sup 3}He detector was used. The obtained data are in good agreement with previous measurements at 0° using 66 MeV proton beam, covering neutron energies >10MeV, as well as with measurements at few selected angles using protons of 46, 55 and 113 MeV energy. The present results extend the neutron yield data in the 60–70 MeV beam energy range. A comparison of measured yields to MCNP, FLUKA and Geant4 Monte Carlo simulations was performed.

  6. The grey fovea sign of macular oedema or subfoveal fluid on non-stereoscopic fundus photographs

    DEFF Research Database (Denmark)

    Hasler, Pascal W; Soliman, Wael; Sander, Birgit

    2017-01-01

    PURPOSE: To describe the grey fovea sign of fovea-involving macular oedema or subretinal fluid accumulation in red-free fundus photography. METHODS: A test set of 91 digital fundus photographs of good quality from 100 consecutive eyes in 72 patients with diabetic retinopathy or central serous...... chorioretinopathy was composed by one of the investigators and evaluated by four masked observers. The photographs were graded as to whether a normal dark fovea was present or absent. The reference method was foveal thickness measurement using optical coherence tomography (OCT). RESULTS: Eyes graded as having...... a grey fovea on fundus photographs (n = 67) had a median foveal thickness of 279 μm (interquartile range 130 μm), whereas eyes graded as having a normal dark fovea (n = 24) had a median foveal thickness of 238 μm (interquartile range 44.5 μm, p = 0.025). CONCLUSION: The absence of a dark fovea on red...

  7. Macular Sensitivity Measured With Microperimetry in Stargardt Disease in the Progression of Atrophy Secondary to Stargardt Disease (ProgStar) Study: Report No. 7.

    Science.gov (United States)

    Schönbach, Etienne M; Wolfson, Yulia; Strauss, Rupert W; Ibrahim, Mohamed A; Kong, Xiangrong; Muñoz, Beatriz; Birch, David G; Cideciyan, Artur V; Hahn, Gesa-Astrid; Nittala, Muneeswar; Sunness, Janet S; Sadda, SriniVas R; West, Sheila K; Scholl, Hendrik P N

    2017-07-01

    New outcome measures for treatment trials for Stargardt disease type 1 (STGD1) and other macular diseases are needed. Microperimetry allows mapping of light sensitivity of the macula and provides topographic information on visual function beyond visual acuity. To measure and analyze retinal light sensitivity of the macula in STGD1 using fundus-controlled perimetry (microperimetry). This was a multicenter prospective cohort study. A total of 199 patients and 326 eyes with molecularly confirmed (ABCA4) STGD1 underwent testing with the Nidek MP-1 microperimeter as part of the multicenter, prospective Natural History of the Progression of Atrophy Secondary to Stargardt Disease (ProgStar) study. Sensitivity of 68 retinal loci was tested, and the mean sensitivity (MS) was determined; each point was categorized as "normal," "relative," or "deep" scotoma. Mean sensitivity and the number of points with normal sensitivity, relative, or deep scotomas. Mean (SD) patient age was 34.2 (14.7) years, mean (SD) best-corrected visual acuity of all eyes was 47.8 (16.9) Early Treatment Diabetic Retinopathy Study letter score (approximately 20/100 Snellen equivalent), and mean MS of all eyes of all 68 points was 11.0 (5.0) dB. The median number of normal points per eye was 49 (mean [SD], 41.3 [20.8]; range, 0-68); abnormal sensitivity and deep scotomas were more prevalent in the central macula. Mean sensitivity was lower in the fovea (mean [SD], 2.7 [4.4] dB) than in the inner (mean [SD], 6.8 [5.8] dB) and outer ring (mean [SD], 12.7 [5.3] dB). Overall MS per eye was 0.086 dB lower per year of additional age (95% CI, -0.13 to -0.041; P clinical trials.

  8. What Is Macular Edema?

    Medline Plus

    Full Text Available ... for Diabetic Macular Edema Jul 17, 2015 Top 5 Risk Factors for AMD Jan 29, 2014 Is Your Laser Pointer Dangerous Enough to Cause Eye Injury? Dec 20, 2013 Study Finds Tablets Help People with Low Vision Nov 27, 2013 Follow The ...

  9. What Is Macular Edema?

    Medline Plus

    Full Text Available ... may be mild to severe, but in many cases, your peripheral (side) vision remains. Macular edema is often a complication of diabetic retinopathy , and is the most common form of vision loss for people with diabetes—particularly if it is left ... Studies Show Zika Virus May Cause More Serious Eye ...

  10. What Is Macular Edema?

    Medline Plus

    Full Text Available ... the retina, where they are transmitted to the brain and interpreted as the images you see. It is the macula that is responsible for your pinpoint vision, allowing you to read, sew or recognize a face. Macular edema develops when blood vessels in the retina are leaking ...

  11. Efficacy of sustained topical dorzolamide therapy for cystic macular lesions in patients with retinitis pigmentosa and usher syndrome.

    Science.gov (United States)

    Genead, Mohamed A; Fishman, Gerald A

    2010-09-01

    To determine the efficacy of sustained topical therapy with dorzolamide hydrochloride, 2%, on visual acuity and cystic macular lesions in patients with retinitis pigmentosa and Usher syndrome. In a retrospective case series at a university hospital, 64 eyes of 32 patients with retinitis pigmentosa or Usher syndrome receiving treatment with the topical dorzolamide formulation for 6 to 58 months were enrolled. Changes in visual acuity on the Early Treatment Diabetic Retinopathy Study chart and central foveal zone thickness on optical coherence tomography were measured during follow-up for the duration of treatment. Among the study cohort, 20 of 32 patients (63%) showed a positive response to treatment in at least 1 eye and 13 patients (41%) showed a pos