  1. Results of Investigative Tests of Gas Turbine Engine Compressor Blades Obtained by Electrochemical Machining

    Science.gov (United States)

    Kozhina, T. D.; Kurochkin, A. V.

    2016-04-01

    The paper highlights results of the investigative tests of GTE compressor Ti-alloy blades obtained by the method of electrochemical machining with oscillating tool-electrodes, carried out in order to define the optimal parameters of the ECM process providing attainment of specified blade quality parameters given in the design documentation, while providing maximal performance. The new technological methods suggested based on the results of the tests; in particular application of vibrating tool-electrodes and employment of locating elements made of high-strength materials, significantly extend the capabilities of this method.

  2. Tests of Machine Intelligence

    CERN Document Server

    Legg, Shane

    2007-01-01

    Although the definition and measurement of intelligence is clearly of fundamental importance to the field of artificial intelligence, no general survey of definitions and tests of machine intelligence exists. Indeed few researchers are even aware of alternatives to the Turing test and its many derivatives. In this paper we fill this gap by providing a short survey of the many tests of machine intelligence that have been proposed.

  3. Test results from Siemens low-speed, high-torque HTS machine and description of further steps towards commercialisation of HTS machines

    Science.gov (United States)

    Nick, Wolfgang; Grundmann, Joern; Frauenhofer, Joachim

    2012-11-01

    With extensive testing of the 4 MW 120 rpm HTS machine connected to a standard Siemens converter this first development stage for a basically new technology is concluded. The most innovative part of the machine, the HTS excited rotor, outperformed our expectations and demonstrated our capability to design, develop and build successfully such a technically challenging component. This could only be achieved on the base of a thorough understanding of the innovative material and its behaviour including practical handling experience, the ability to simulate 3D electromagnetics including transients, and finally transfer of the scientists' knowledge to a qualified manufacturing process. Equally important are the improved capabilities of critical component suppliers, e.g. for superconducting tapes and compact cryo-refrigerators. However, the transition of a technology into highly reliable industrial products does require more than technical mastering of the machine. Based on outstanding technical test results as presented above, the next step in future can be addressed: product development. Some thoughts will be presented regarding the needs of application fields and market oriented development, as the market is not "waiting for HTS". If HTS technology is seen as one key technology for a sustainable, material saving and energy efficient future, it certainly needs more effort, even at the 100th anniversary of superconductivity.

  4. 380 kW synchronous machine with HTS rotor windings--development at Siemens and first test results

    Science.gov (United States)

    Nick, W.; Nerowski, G.; Neumüller, H.-W.; Frank, M.; van Hasselt, P.; Frauenhofer, J.; Steinmeyer, F.

    2002-08-01

    Applying HTS conductors in the rotor of synchronous machines allows the design of future motors or generators that are lighter, more compact and feature an improved coefficient of performance. To address these goals a project collaboration was installed within Siemens, including Automation & Drives, Large Drives as a leading supplier of electrical machines, Corporate Technology as a competence center for superconducting technology, and other partners. The main task of the project was to demonstrate the feasibility of basic concepts. The rotor was built from racetrack coils of Bi-2223 HTS tape conductor, these were assembled on a core and fixed by a bandage of glass-fibre composite. Rotor coil cooling is performed by thermal conduction, one end of the motor shaft is hollow to give access for the cooling system. Two cooling systems were designed and operated successfully: firstly an open circuit using cold gaseous helium from a storage vessel, but also a closed circuit system based on a cryogenerator. To take advantage of the increased rotor induction levels the stator winding was designed as an air gap winding. This was manufactured and fitted in a standard motor housing. After assembling of the whole system in a test facility with a DC machine load experiments have been started to prove the validity of our design, including operation with both cooling systems and driving the stator from the grid as well as by a power inverter.

  5. 麻醉机质量控制检测与结果的分析%Analysis of quality control testing and results of the anesthesia machine

    Institute of Scientific and Technical Information of China (English)

    黄韬; 崔骊; 李向东; 云庆辉

    2013-01-01

    目的:通过对麻醉机的质量控制检测,分析造成麻醉机不合格的主要原因,并采取相应措施确保麻醉机的安全使用。方法:使用美国VT-PLUS-HF气流分析仪对医院麻醉机定期检测,并利用检测结果对麻醉机的质量状况进行统计分析,评估不合格因素。结果:通过对医院麻醉机定期检测和分析检测结果,采取相应的方法消除了多台麻醉机的安全隐患,保障其使用安全。结论:麻醉机的质量控制检测工作是医疗安全的重要组成部分,通过检测能够及时发现和消除麻醉机的安全隐患,确保患者的生命安全。%Objective:Though the result study of quality control testing of anesthesia machine by 4 yesrs, the factors to anesthesia machine failure is investigated, and the proposal of improving the quality of the equipment testing standards is given. Methods:Statistical analysis the quality of the anesthesia machines using the VT-PLUS-HF gas analyzers with U.S.FLUKE Corporation is used, the test results can be to assess the quality of the anesthesia machine fail factors. Results: Through regular detection, not only can anesthesia machine potential risk be eliminated but also quality safety of clinical use will be safeguarded. Conclusion: Quality control detection to anesthesia machine is an important component of medical safety. It concluded that detect the anesthesia machine security risks by quality controls, ensure the life safety of patients.

  6. THE RESULTS OF MACHINE-TRACTOR UNIT’S TESTS ON THE BASIS OF A 1,4 TRACTOR HAVING A ROTARY MASS OF THE ENGINE

    Directory of Open Access Journals (Sweden)

    Kravchenko V. A.

    2014-05-01

    Full Text Available The article contains the results of machine-tractor unit’s researches on the basis of a class 1,4 tractor having a variable rotary mass of the engine. It is concluded that the use of additional rotary mass being linked at corresponding regimes of motion to the engine’s shaft or primary transmission shaft at the tractor furthers the improvement of operation indexes of a machine-tractor unit

  7. IQ tests are not for machines, yet

    OpenAIRE

    2012-01-01

    Complex, but specific, tasks¿such as chess or Jeopardy!¿are popularly seen as milestones for artificial intelligence (AI). However, they are not appropriate for evaluating the intelligence of machines or measuring the progress in AI. Aware of this delusion, Detterman has recently raised a challenge prompting AI researchers to evaluate their artefacts against IQ tests. We agree that the philosophy behind (human) IQ tests is a much better approach to machine intelligence evaluation than these s...

  8. Cholesterol testing and results

    Science.gov (United States)

    Cholesterol test results; LDL test results; VLDL test results; HDL test results; Coronary risk profile results; Hyperlipidemia- ... Some cholesterol is considered good and some is considered bad. Different blood tests can be done to measure each ...

  9. Testing and Modeling of Machine Properties in Resistance Welding

    DEFF Research Database (Denmark)

    Wu, Pei

    electrode force, and the time of stabilizing does not depend on the level of the force. An additional spring mounted in the welding head improves the machine touching behavior due to a soft electrode application, but this results in longer time of oscillation of the electrode force, especially when......The objective of this work has been to test and model the machine properties including the mechanical properties and the electrical properties in resistance welding. The results are used to simulate the welding process more accurately. The state of the art in testing and modeling machine properties...... in resistance welding has been described based on a comprehensive literature study. The present thesis has been subdivided into two parts: Part I: Mechanical properties of resistance welding machines. Part II: Electrical properties of resistance welding machines. In part I, the electrode force in the squeeze...

  10. Rotating electrical machines part 4: methods for determining synchronous machine quantities from tests

    CERN Document Server

    International Electrotechnical Commission. Geneva

    1985-01-01

    Applies to three-phase synchronous machines of 1 kVA rating and larger with rated frequency of not more than 400 Hz and not less than 15 Hz. An appendix gives unconfirmed test methods for determining synchronous machine quantities. Notes: 1 -Tests are not applicable to synchronous machines such as permanent magnet field machines, inductor type machines, etc. 2 -They also apply to brushless machines, but certain variations exist and special precautions should be taken.

  11. Machine for development impact tests in sports seats and similar

    Science.gov (United States)

    Gonçalves, R. M.

    2015-10-01

    This paper describes the stages of development of a machine to perform impact tests in sport seats, seats for spectators and multiple seats. This includes reviews and recommendations for testing laboratories that have needs similar to the laboratory where unfolded this process.The machine was originally developed seeking to meet certain impact tests in accordance with the NBR15925 standards; 15878 and 16031. The process initially included the study of the rules and the election of the tests for which the machine could be developed and yet all reports and outcome of interaction with service providers and raw materials.For operating facility, it was necessary to set entirely the machine control, which included the concept of dialogue with operator, the design of the menu screens and the procedures for submission and registration of results. To ensure reliability in the process, the machine has been successfully calibrated according to the requirements of the Brazilian network of calibration.The criticism to this enterprise covers the technical and economic aspects involved and points out the main obstacles that were needed to overcome.

  12. Human Machine Interface Programming and Testing

    Science.gov (United States)

    Foster, Thomas Garrison

    2013-01-01

    Human Machine Interface (HMI) Programming and Testing is about creating graphical displays to mimic mission critical ground control systems in order to provide NASA engineers with the ability to monitor the health management of these systems in real time. The Health Management System (HMS) is an online interactive human machine interface system that monitors all Kennedy Ground Control Subsystem (KGCS) hardware in the field. The Health Management System is essential to NASA engineers because it allows remote control and monitoring of the health management systems of all the Programmable Logic Controllers (PLC) and associated field devices. KGCS will have equipment installed at the launch pad, Vehicle Assembly Building, Mobile Launcher, as well as the Multi-Purpose Processing Facility. I am designing graphical displays to monitor and control new modules that will be integrated into the HMS. The design of the display screen will closely mimic the appearance and functionality of the actual modules. There are many different field devices used to monitor health management and each device has its own unique set of health management related data, therefore each display must also have its own unique way to display this data. Once the displays are created, the RSLogix5000 application is used to write software that maps all the required data read from the hardware to the graphical display. Once this data is mapped to its corresponding display item, the graphical display and hardware device will be connected through the same network in order to test all possible scenarios and types of data the graphical display was designed to receive. Test Procedures will be written to thoroughly test out the displays and ensure that they are working correctly before being deployed to the field. Additionally, the Kennedy Ground Controls Subsystem's user manual will be updated to explain to the NASA engineers how to use the new module displays.

  13. Identification of Kinematic Errors of Five-axis Machine Tool Trunnion Axis from Finished Test Piece

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ya; FU Jianzhong; CHEN Zichen

    2014-01-01

    Compared with the traditional non-cutting measurement, machining tests can more accurately reflect the kinematic errors of five-axis machine tools in the actual machining process for the users. However, measurement and calculation of the machining tests in the literature are quite difficult and time-consuming. A new method of the machining tests for the trunnion axis of five-axis machine tool is proposed. Firstly, a simple mathematical model of the cradle-type five-axis machine tool was established by optimizing the coordinate system settings based on robot kinematics. Then, the machining tests based on error-sensitive directions were proposed to identify the kinematic errors of the trunnion axis of cradle-type five-axis machine tool. By adopting the error-sensitive vectors in the matrix calculation, the functional relationship equations between the machining errors of the test piece in the error-sensitive directions and the kinematic errors of C-axis and A-axis of five-axis machine tool rotary table was established based on the model of the kinematic errors. According to our previous work, the kinematic errors of C-axis can be treated as the known quantities, and the kinematic errors of A-axis can be obtained from the equations. This method was tested in Mikron UCP600 vertical machining center. The machining errors in the error-sensitive directions can be obtained by CMM inspection from the finished test piece to identify the kinematic errors of five-axis machine tool trunnion axis. Experimental results demonstrated that the proposed method can reduce the complexity, cost, and the time consumed substantially, and has a wider applicability. This paper proposes a new method of the machining tests for the trunnion axis of five-axis machine tool.

  14. GIRAFFE test results summary

    Energy Technology Data Exchange (ETDEWEB)

    Yokobori, S.; Arai, K.; Oikawa, H. [Toshiba Corporation, Kawasaki (Japan)

    1996-03-01

    A passive system can provide engineered safety features enhancing safety system reliability and plant simplicity. Toshiba has conducted the test Program to demonstrate the feasibility of the SBWR passive safety system using a full-height, integral system test facility GIRAFFE. The test facility GIRAFFE models the SBWR in full height to correctly present the gravity driving head forces with a 1/400 volume scale. The GIRAFFE test Program includes the certification tests of the passive containment cooling system (PCCS) to remove the post-accident decay heat and the gravity driven cooling system (GDCS) to replenish the reactor coolant inventory during a LOCA. The test results have confirmed the PCCS and GDCS design and in addition, have demonstrated the operation of the pCCS with the presence of a lighter-than-steam noncondensable as well as with the presence of a heavier-than-steam, noncondensable. The GIRAFFE test Program has also provided the database to qualify a best estimate thermal-hydraulic computer code TRAC. The post test analysis results have shown that TRAC can accurately predict the PCCS heat removal Performance and the containment pressure response to a LOCA. This paper summarizes the GIRAFFE test results to investigate post-LOCA PCCS heat removal performance and post-test analysis using TRAC.

  15. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  16. Testing and Validating Machine Learning Classifiers by Metamorphic Testing☆

    Science.gov (United States)

    Xie, Xiaoyuan; Ho, Joshua W. K.; Murphy, Christian; Kaiser, Gail; Xu, Baowen; Chen, Tsong Yueh

    2011-01-01

    Machine Learning algorithms have provided core functionality to many application domains - such as bioinformatics, computational linguistics, etc. However, it is difficult to detect faults in such applications because often there is no “test oracle” to verify the correctness of the computed outputs. To help address the software quality, in this paper we present a technique for testing the implementations of machine learning classification algorithms which support such applications. Our approach is based on the technique “metamorphic testing”, which has been shown to be effective to alleviate the oracle problem. Also presented include a case study on a real-world machine learning application framework, and a discussion of how programmers implementing machine learning algorithms can avoid the common pitfalls discovered in our study. We also conduct mutation analysis and cross-validation, which reveal that our method has high effectiveness in killing mutants, and that observing expected cross-validation result alone is not sufficiently effective to detect faults in a supervised classification program. The effectiveness of metamorphic testing is further confirmed by the detection of real faults in a popular open-source classification program. PMID:21532969

  17. Ibis DDT test results

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This document contains test results from a study done to determine the organochlorine levels in the livers of white-faced ibis from Stillwater Wildlife Management...

  18. ANALYSIS AND SIMULATION ON THE MECHANISM OF A NOVEL DUAL-WAVE SHOCK TEST MACHINE

    Institute of Scientific and Technical Information of China (English)

    WANG Gongxian; ZHANG Zhiyi; CHU Deying; SHEN Rongying

    2008-01-01

    For qualifying the anti-shock performance of shipboard equipments and simulating actual underwater explosion environments, a novel dual-wave shock test machine is proposed to increase testing capability of shock test machines as well as to meet certain shock testing specification. The machine can generate a double-pulse acceleration shock for test articles according to specification defined in BV043/85. On the basis of the impact theory, a nonlinear dynamic model of the hydraulically-actuated test machine is established with thorough analysis on its mechanism which involves conversion of gas potential energy and dissipation of kinetic energy. Simulation results have demonstrated that the machine can produce a double-pulse acceleration shock in the time domain or a desired shock response spectrum in the frequency domain, which sets a theoretical base for the construction of the proposed machine.

  19. Development of a Test Machine for IVECO Drive Axle

    Institute of Scientific and Technical Information of China (English)

    WANG Liang-mo; WANG He-fu; CHEN Jin-rong; LING Zhi-liang; CAO Yu-hua

    2007-01-01

    To improve the automation level of the vehicle drive axle test and better simulate a vehicle′s actual operation, an advanced test machine has been developed. The load system of the machine consists of hand brakes and electric cylinders. It is simple-structured and low-cost. The major motor of the machine is controlled by a transducer and its speed can be adjusted easily. In addition, the programmed machine can automatically test such parameters as the grinding condition, the differential speed, the noise level, etc. It can also adjust the test procedures according to different requirements. Detailed discussion of the structure and mechanism of the test machine is given in this paper.

  20. Laboratory Test of Vending Machine with Advanced Defrosting Technology and Integrated Accumulatory/Expander Concept

    Energy Technology Data Exchange (ETDEWEB)

    Bryne, M E; Domitrovic, R E; Mei, V C; Chen, F C; Fransson, J H.M.

    2000-10-01

    The manufacturer delivered an off-the-shelf soft drink vending machine for testing to ORNL. The machine was tested for baseline performance and it was found that the cold air passage was not properly designed. An inadequate cold air supply to the product resulted in recirculation of the evaporator air and heavy frost accumulation on the evaporator coil.

  1. Modification and Performance Evaluation of a Low Cost Electro-Mechanically Operated Creep Testing Machine

    Directory of Open Access Journals (Sweden)

    John J. MOMOH

    2010-12-01

    Full Text Available Existing mechanically operated tensile and creep testing machine was modified to a low cost, electro-mechanically operated creep testing machine capable of determining the creep properties of aluminum, lead and thermoplastic materials as a function of applied stress, time and temperature. The modification of the testing machine was necessitated by having an electro-mechanically operated creep testing machine as a demonstration model ideal for use and laboratory demonstrations, which will provide an economical means of performing standard creep experiments. The experimental result is a more comprehensive understanding of the laboratory experience, as the technology behind the creep testing machine, the test methodology and the response of materials loaded during experiment are explored. The machine provides a low cost solution for Mechanics of Materials laboratories interested in creep testing experiment and demonstration but not capable of funding the acquisition of commercially available creep testing machines. Creep curves of strain versus time on a thermoplastic material were plotted at a stress level of 1.95MPa, 3.25MPa and 4.55MPa and temperature of 20oC, 40oC and 60oC respectively. The machine is satisfactory since it is always ready for operation at any given time.

  2. Understanding Your Test Results

    Science.gov (United States)

    ... serum: IgA, IgM, and IgG. It measures both polyclonal (normal) and monoclonal (myeloma-related) immunoglobulin, so if an increase in one of the antibody isotypes is found, further testing with electrophoresis is ...

  3. Initial experimental results of a machine learning-based temperature control system for an RF gun

    CERN Document Server

    Edelen, A L; Milton, S V; Chase, B E; Crawford, D J; Eddy, N; Edstrom, D; Harms, E R; Ruan, J; Santucci, J K; Stabile, P

    2015-01-01

    Colorado State University (CSU) and Fermi National Accelerator Laboratory (Fermilab) have been developing a control system to regulate the resonant frequency of an RF electron gun. As part of this effort, we present initial test results for a benchmark temperature controller that combines a machine learning-based model and a predictive control algorithm. This is part of an on-going effort to develop adaptive, machine learning-based tools specifically to address control challenges found in particle accelerator systems.

  4. Testing and Modeling of Mechanical Characteristics of Resistance Welding Machines

    DEFF Research Database (Denmark)

    Wu, Pei; Zhang, Wenqi; Bay, Niels;

    2003-01-01

    The dynamic mechanical response of resistance welding machine is very important to the weld quality in resistance welding especially in projection welding when collapse or deformation of work piece occurs. It is mainly governed by the mechanical parameters of machine. In this paper, a mathematical...... for both upper and lower electrode systems. This has laid a foundation for modeling the welding process and selecting the welding parameters considering the machine factors. The method is straightforward and easy to be applied in industry since the whole procedure is based on tests with no requirements...

  5. Your Kidney Test Results

    Science.gov (United States)

    ... Less than 200 Your Result: HDL Cholesterol LDL Cholesterol Triglycerides Hemoglobin (Hgb) *Normal ranges may vary. Normal: More ... out of your arteries. LDL is the bad cholesterol and can clog your arteries. Triglyceride is a type of fat in the blood. ...

  6. Boxing headguard performance in punch machine tests.

    Science.gov (United States)

    McIntosh, Andrew S; Patton, Declan A

    2015-09-01

    The paper presents a novel laboratory method for assessing boxing headguard impact performance. The method is applied to examine the effects of headguards on head impact dynamics and injury risk. A linear impactor was developed, and a range of impacts was delivered to an instrumented Hybrid III head and neck system both with and without an AIBA (Association Internationale de Boxe Amateur)-approved headguard. Impacts at selected speeds between 4.1 and 8.3 m/s were undertaken. The impactor mass was approximately 4 kg and an interface comprising a semirigid 'fist' with a glove was used. The peak contact forces were in the range 1.9-5.9 kN. Differences in head impact responses between the Top Ten AIBA-approved headguard and bare headform in the lateral and forehead tests were large and/or significant. In the 8.3 m/s fist-glove impacts, the mean peak resultant headform accelerations for bare headform tests was approximately 130 g compared with approximately 85 g in the forehead impacts. In the 6.85 m/s bare headform impacts, mean peak resultant angular head accelerations were in the range of 5200-5600 rad/s(2) and almost halved by the headguard. Linear and angular accelerations in 45° forehead and 60° jaw impacts were reduced by the headguard. The data support the opinion that current AIBA headguards can play an important role in reducing the risk of concussion and superficial injury in boxing competition and training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  8. Organic Separation Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Rinehart, Donald E.; Peterson, Reid A.

    2014-09-22

    Separable organics have been defined as “those organic compounds of very limited solubility in the bulk waste and that can form a separate liquid phase or layer” (Smalley and Nguyen 2013), and result from three main solvent extraction processes: U Plant Uranium Recovery Process, B Plant Waste Fractionation Process, and Plutonium Uranium Extraction (PUREX) Process. The primary organic solvents associated with tank solids are TBP, D2EHPA, and NPH. There is concern that, while this organic material is bound to the sludge particles as it is stored in the tanks, waste feed delivery activities, specifically transfer pump and mixer pump operations, could cause the organics to form a separated layer in the tank farms feed tank. Therefore, Washington River Protection Solutions (WRPS) is experimentally evaluating the potential of organic solvents separating from the tank solids (sludge) during waste feed delivery activities, specifically the waste mixing and transfer processes. Given the Hanford Tank Waste Treatment and Immobilization Plant (WTP) waste acceptance criteria per the Waste Feed Acceptance Criteria document (24590-WTP-RPT-MGT-11-014) that there is to be “no visible layer” of separable organics in the waste feed, this would result in the batch being unacceptable to transfer to WTP. This study is of particular importance to WRPS because of these WTP requirements.

  9. Design and Construction of a Spring Stiffness Testing Machine

    Directory of Open Access Journals (Sweden)

    Olugboji Oluwafemi Ayodeji

    2015-04-01

    Full Text Available A spring stiffness testing machine was produced which differentiates a good spring from bad one using hydraulic principle and locally sourced materials were used to produce at relative low cost and high efficiency. It also categories each spring by stiffness into one of several distinct categories based on its performance under test. This is to ensure that in the final assembly process, springs with similar performance characteristics are mated to ensure a better ride, more précised handling and improved overall vehicle or equipment performance. The construction of the machine involves basically the fabrication process which includes such operation as cutting, benching, welding, grinding, drilling, machining, casting and screw fastening. Taken into consideration under test, were types of compression springs with varying spring loading and their different displacement recorded at different pressures to compare their stiffness.

  10. Increase of energy efficiency of testing of traction electric machines of direct and pulsating current

    Directory of Open Access Journals (Sweden)

    A.M. Afanasov

    2015-03-01

    Full Text Available The results of the analysis of the effect of the load current of traction electric machines when tested for heating on the total electricity consumption for the test are presented. It is shown that increase of load current at the heating test permits to significantly reduce the consumption of electrical energy, and reduce the testing time without reducing its quality.

  11. An Adaptive Genetic Association Test Using Double Kernel Machines.

    Science.gov (United States)

    Zhan, Xiang; Epstein, Michael P; Ghosh, Debashis

    2015-10-01

    Recently, gene set-based approaches have become very popular in gene expression profiling studies for assessing how genetic variants are related to disease outcomes. Since most genes are not differentially expressed, existing pathway tests considering all genes within a pathway suffer from considerable noise and power loss. Moreover, for a differentially expressed pathway, it is of interest to select important genes that drive the effect of the pathway. In this article, we propose an adaptive association test using double kernel machines (DKM), which can both select important genes within the pathway as well as test for the overall genetic pathway effect. This DKM procedure first uses the garrote kernel machines (GKM) test for the purposes of subset selection and then the least squares kernel machine (LSKM) test for testing the effect of the subset of genes. An appealing feature of the kernel machine framework is that it can provide a flexible and unified method for multi-dimensional modeling of the genetic pathway effect allowing for both parametric and nonparametric components. This DKM approach is illustrated with application to simulated data as well as to data from a neuroimaging genetics study.

  12. Random non-proportional fatigue tests with planar tri-axial fatigue testing machine

    Directory of Open Access Journals (Sweden)

    T. Inoue

    2016-10-01

    Full Text Available Complex stresses, which occur on the mechanical surfaces of transport machinery in service, bring a drastic degradation in fatigue life. However, it is hard to reproduce such complex stress states for evaluating the fatigue life with conventional multiaxial fatigue machines. We have developed a fatigue testing machine that enables reproduction of such complex stresses. The testing machine can reproduce arbitrary in-plane stress states by applying three independent loads to the test specimen using actuators which apply loads in the 0, 45, and 90 degree directions. The reproduction was tested with complex stress data obtained from the actual operation of transport machinery. As a result, it was found that the reproduced stress corresponded to the measured stress with an error range of less than 10 %. Then, we made a comparison between measured fatigue lives under random non-proportional loading conditions and predicted fatigue lives. It was found that predicted fatigue lives with cr, stress on critical plane, were over a factor of 10 against measured fatigue lives. On the other hand, predicted fatigue lives with ma, stress in consideration of a non-proportional level evaluated by using amplitude and direction of principal stress, were within a factor of 3 against measured fatigue lives

  13. Modelling, Construction, and Testing of a Simple HTS Machine Demonstrator

    DEFF Research Database (Denmark)

    Jensen, Bogi Bech; Abrahamsen, Asger Bech

    2011-01-01

    This paper describes the construction, modeling and experimental testing of a high temperature superconducting (HTS) machine prototype employing second generation (2G) coated conductors in the field winding. The prototype is constructed in a simple way, with the purpose of having an inexpensive w...

  14. Design and production of a novel sand materials strength testing machine for foundry applications

    DEFF Research Database (Denmark)

    Nwaogu, Ugochukwu Chibuzoh; Hansen, K. S.; Tiedje, Niels Skat

    2012-01-01

    In the foundry, existing strength testing machines are used to measure only the maximum fracture strength of mould and core materials. With traditionally used methods, the loading history to ascertain deformation of the material is not available. In this paper, a novel moulding material strength...... testing machine was designed and built for both green sand and chemically-bonded sand materials. This machine measures and presents the loading response as a force-displacement profile from which the mechanical properties of the moulding materials can be deduced. The system was interfaced to a computer....... The force was calibrated using an Amsler Hydraulic Press while the displacements were calibrated with and without loading using a displacement calibrator (Heidenhain Digitaler). The calibration results showed that the data obtained are stable and reliable and the machine can be used for the measurement...

  15. A New Method for Incremental Testing of Finite State Machines

    Science.gov (United States)

    Pedrosa, Lehilton Lelis Chaves; Moura, Arnaldo Vieira

    2010-01-01

    The automatic generation of test cases is an important issue for conformance testing of several critical systems. We present a new method for the derivation of test suites when the specification is modeled as a combined Finite State Machine (FSM). A combined FSM is obtained conjoining previously tested submachines with newly added states. This new concept is used to describe a fault model suitable for incremental testing of new systems, or for retesting modified implementations. For this fault model, only the newly added or modified states need to be tested, thereby considerably reducing the size of the test suites. The new method is a generalization of the well-known W-method and the G-method, but is scalable, and so it can be used to test FSMs with an arbitrarily large number of states.

  16. Standard practice for torque calibration of testing machines and devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers procedures and requirements for the calibration of torque for static and quasi-static torque capable testing machines or devices. These may, or may not, have torque indicating systems and include those devices used for the calibration of hand torque tools. Testing machines may be calibrated by one of the three following methods or combination thereof: 1.1.1 Use of standard weights and lever arms. 1.1.2 Use of elastic torque measuring devices. 1.1.3 Use of elastic force measuring devices and lever arms. 1.1.4 Any of the methods require a specific uncertainty of measurement and a traceability derived from national standards of mass and length. 1.2 The procedures of 1.1.1, 1.1.2, and 1.1.3 apply to the calibration of the torque-indicating systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the torque-indicating system(s) to be calibrated and included in the repor...

  17. ISOCAM experiment cryogenic test results

    Science.gov (United States)

    de Sa, L.; Collaudin, B.

    The thermal requirements for ISOCAM, an IR camera to be mounted aboard the ISO satellite, are reviewed, and model predictions are matched with test results. The degree of model validation suggested by analytical prediction vs test results is described. Predictions of thermal conduction through mounting screws, from ball bearings, and of the heat distribution in the rotor and stator of a cryogenic stepper motor correlate well with actual test results. It is shown that ISOCAM meets the thermal requirements necessary for successful on-orbit operation. The model predicted such phenomena as 'chopped' motor function and the twofold increase in temperature resulting from continuous motor operation.

  18. A Machine Learning Approach to Test Data Generation

    DEFF Research Database (Denmark)

    Christiansen, Henning; Dahmcke, Christina Mackeprang

    2007-01-01

    Programs for gene prediction in computational biology are examples of systems for which the acquisition of authentic test data is difficult as these require years of extensive research. This has lead to test methods based on semiartificially produced test data, often produced by {\\em ad hoc......} techniques complemented by statistical models such as Hidden Markov Models (HMM). The quality of such a test method depends on how well the test data reflect the regularities in known data and how well they generalize these regularities. So far only very simplified and generalized, artificial data sets have...... been tested, and a more thorough statistical foundation is required. We propose to use logic-statistical modelling methods for machine-learning for analyzing existing and manually marked up data, integrated with the generation of new, artificial data. More specifically, we suggest to use the PRISM...

  19. Simulation and experimental results of hybrid electric machine with a novel flux control strategy

    Directory of Open Access Journals (Sweden)

    Paplicki Piotr

    2015-03-01

    Full Text Available The paper presents selected simulation and experimental results of a hybrid ECPMS-machine (Electric Controlled Permanent Magnet Synchronous Machine. This permanent magnets (PMs excited machine offers an extended magnetic field control capability which makes it suitable for battery electric vehicle (BEV drives. Rotor, stator and the additional direct current control coil of the machine are analyzed in detail. The control system and strategy, the diagram of power supply system and an equivalent circuit model of the ECPMS-machine are presented. Influence of the additional excitation on the performance parameters of the machine, such as: torque, efficiency, speed limits and back-EMF have also been discussed.

  20. Machine-learned pattern identification in olfactory subtest results

    Science.gov (United States)

    Lötsch, Jörn; Hummel, Thomas; Ultsch, Alfred

    2016-01-01

    The human sense of smell is often analyzed as being composed of three main components comprising olfactory threshold, odor discrimination and the ability to identify odors. A relevant distinction of the three components and their differential changes in distinct disorders remains a research focus. The present data-driven analysis aimed at establishing a cluster structure in the pattern of olfactory subtest results. Therefore, unsupervised machine-learning was applied onto olfactory subtest results acquired in 10,714 subjects with nine different olfactory pathologies. Using the U-matrix, Emergent Self-organizing feature maps (ESOM) identified three different clusters characterized by (i) low threshold and good discrimination and identification, (ii) very high threshold associated with absent to poor discrimination and identification ability, or (iii) medium threshold, i.e., in the mid-range of possible thresholds, associated with reduced discrimination and identification ability. Specific etiologies of olfactory (dys)function were unequally represented in the clusters (p pattern recognition. PMID:27762302

  1. A Machine Learning Approach to Test Data Generation

    DEFF Research Database (Denmark)

    Christiansen, Henning; Dahmcke, Christina Mackeprang

    2007-01-01

    been tested, and a more thorough statistical foundation is required. We propose to use logic-statistical modelling methods for machine-learning for analyzing existing and manually marked up data, integrated with the generation of new, artificial data. More specifically, we suggest to use the PRISM...... system developed by Sato and Kameya. Based on logic programming extended with random variables and parameter learning, PRISM appears as a powerful modelling environment, which subsumes HMMs and a wide range of other methods, all embedded in a declarative language. We illustrate these principles here...

  2. NCV Flow Diagnostic Test Results

    Science.gov (United States)

    Cappuccio, Mina

    1999-01-01

    There were two objectives for this test. First, was to assess the reasons why there is approximately 1.5 drag counts (cts) discrepancy between measured and computed drag improvement of the Non-linear Cruise Validation (NCV) over the Technology Concept Airplane (TCA) wing body (WB) configurations. The Navier-Stokes (N-S) pre-test predictions from Boeing Commercial Airplane Group (BCAG) show 4.5 drag cts of improvement for NCV over TCA at a lift coefficient (CL) of 0. I at Mach 2.4. The pre-test predictions from Boeing Phantom Works - Long Beach, BPW-LB, show 3.75 drag cts of improvement. BCAG used OVERFLOW and BPW-LB used CFL3D. The first test entry to validate the improvement was held at the NASA Langley Research Center (LARC) UPV;T, test number 1687. The experimental results showed that the drag improvement was only 2.6 cts, not accounting for laminar run and trip drag. This is approximately 1.5 cts less than predicted computationally. In addition to the low Reynolds Number (RN) test, there was a high RN test in the Boeing Supersonic Wind Tunnel (BSWT) of NCV and TCA. BSV@T test 647 showed that the drag improvement of NCV over TCA was also 2.6 cts, but this did account for laminar run and trip drag. Every effort needed to be done to assess if the improvement measured in LaRC UPWT and BSWT was correct. The second objective, once the first objective was met, was to assess the performance increment of NCV over TCA accounting for the associated laminar run and trip drag corrections in LaRC UPWT. We know that the configurations tested have laminar flow on portions of the wing and have trip drag due to the mechanisms used to force the flow to go from laminar to turbulent aft of the transition location.

  3. Improved method for SNR prediction in machine-learning-based test

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.

    2010-01-01

    This paper applies an improved method for testing the signal-to-noise ratio (SNR) of Analogue-to-Digital Converters (ADC). In previous work, a noisy and nonlinear pulse signal is exploited as the input stimulus to obtain the signature results of ADC. By applying a machine-learning-based approach, th

  4. Improved method for SNR prediction in machine-learning-based test

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.

    2010-01-01

    This paper applies an improved method for testing the signal-to-noise ratio (SNR) of Analogue-to-Digital Converters (ADC). In previous work, a noisy and nonlinear pulse signal is exploited as the input stimulus to obtain the signature results of ADC. By applying a machine-learning-based approach, th

  5. Design of new frictional testing machine for shallow fault materials

    Science.gov (United States)

    Tadai, O.; Tanikawa, W.; Hirose, T.; Sakaguchi, M.; Lin, W.

    2009-12-01

    Subduction thrust faults at shallow depth mainly consist of granular and clay-rich materials which strengths are influenced by the presence of pore water. Dilatation and pore pressure generation of fault zones by the dynamic friction will increase the volumetric water content in fault zone, which can assist the fault weakening by acoustic fluidization or hydrodynamic lubrication mechanism. Therefore the evaluation of rheology for clay minerals rich in pore water is critical for understanding of seismic behaviors at shallow depth. Here, we introduce a new testing apparatus for the purpose of accurate evaluation of friction behavior for incohesive fault rock materials. Our machine can shear granular materials up to 80 mm of outer diameter and maximum thickness of 40 mm. The capacities of axial load, torque, and motor are 100kN, 500Nm and 30kW, respectively, and pore pressure is increased up to 50 MPa. Maximum rotation speed is 660 rpm, which is equivalent to 1 m/s of the average slip velocity when sample diameter is 60 mm. We can monitor the dynamic changes of pore pressure and temperature at sliding surface during the friction tests. We can also control the pore pressure, axial load, pore pressure and temperature independently. All parameters can be held at targeted values and be generated at constant incremental velocity. We can control the rotation more sensitively to program the complicated rotation history that slip velocity and acceleration change during the rotation. We used powdered smectite and illite in our friction tests. We measured normal stress dependence on shear stress at normal stress up to 25 MPa with a constant rotation speed from 0.01 to 1 rpm. Normal stress is proportional to shear stress for dry clay minerals, and the friction coefficients are from 0.3 to 0.5. On the other hand, very low friction is observed in clay minerals saturated by water, and shear strength is nearly constant at various normal stresses. Our results suggest that clay

  6. Machines as organisms: an exploration of the relevance of recent results.

    Science.gov (United States)

    Laing, R

    1979-08-01

    The capacity of machines to exhibit organism-like behavior is examined. Some known results on machine description, self-description, construction and self-construction, are reviewed. The basic mechanism of machines and the ways in which they can be combined to form more complex biological-like systems are put forth as a source of explanatory mechanisms in biology. The proven properties can be employed in the design of machines which can repair themselves, and can exhibit a behavior distinguishing between machines which are or are not structurally similar to themselves. It is then argued that in an appropriate setting of variation and competition, such behavior would arise without explicit design.

  7. A microdynamic version of the tensile test machine

    Science.gov (United States)

    Glaser, R. J.

    1991-01-01

    Very large space structures require structural reactions to control forces associated with nanometer-level displacements; JPL has accordingly built a tensile test machine capable of mN-level force measurements and nm-level displacement measurements, with a view to the study of structural linear joining technology at the lower limit of its resolution. The tester is composed of a moving table that is supported by six flexured legs and a test specimen cantilevered off the table to ground. Three vertical legs contain piezoactuators allowing changes in length up to 200 microns while generating axial load and bending moments. Displacements between ground and table are measured by means of three laser-interferometric channels.

  8. NUMERICAL MODELING OF MULTICYLINDER ELECTRO-HYDRAULIC SYSTEM AND CONTROLLER DESIGN FOR SHOCK TEST MACHINE

    Institute of Scientific and Technical Information of China (English)

    CHU Deying; ZHANG Zhiyi; WANG Gongxian; HUA Hongxing

    2007-01-01

    A high fidelity dynamic model of a high-energy hydraulically-actuated shock test machine for heavy weight devices is presented to satisfy the newly-built shock resistance standard and simulate the actual underwater explosion environments in laboratory as well as increase the testing capability of shock test machine. In order to produce the required negative shock pulse in the given time duration, four hydraulic actuators are utilized. The model is then used to formulate an advanced feedforward controller for the system to produce the required negative waveform and to address the motion synchronization of the four cylinders. The model provides a safe and easily controllable way to perform a "virtual testing" before starting potentially destructive tests on specimen and to predict performance of the system. Simulation results have demonstrated the effectiveness of the controller.

  9. Methodology of Testing Shot Blasting Machines in Industrial Conditions

    Directory of Open Access Journals (Sweden)

    R. Wrona

    2012-04-01

    Full Text Available Shot blasting machines are widely used for automated surface treatment and finishing of castings. In shot blasting processes the stream of shots is generated and shaped by blasting turbines, making up a kinetic and dynamic system comprising a separating rotor, an adapting sleeve and a propelling rotor provided with blades. The shot blasting performance- i.e. the quality of shot treated surfaces depends on the actual design and operational parameters of the unit whilst the values of relevant parameters are associated with the geometry of turbine components and the level of its integration with the separator system. The circulation of the blasting medium becomes the integrating factor of the process line, starting from the hopper, through the propeller turbine, casting treatment, separation of contaminated abrasive mixture, to its recycling and reuse.Inferior quality of the abrasive agent (shot and insufficient purity of the abrasive mixture are responsible for low effectiveness of shot blasting. However, most practitioners fail to fully recognise the importance of proper diagnostics of the shot blasting process in industrial conditions. The wearing of major machine components and of the blasting agent and quality of shot treated surfaces are often misinterpreted, hence the need to take into account all factors involved in the process within the frame of a comprehensive methodology.This paper is an attempt to formulate and apply the available testing methods to the engineering practice in industrial conditions.

  10. RSG Deployment Case Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Owsley, Stanley L.; Dodson, Michael G.; Hatchell, Brian K.; Seim, Thomas A.; Alexander, David L.; Hawthorne, Woodrow T.

    2005-09-01

    The RSG deployment case design is centered on taking the RSG system and producing a transport case that houses the RSG in a safe and controlled manner for transport. The transport case was driven by two conflicting constraints, first that the case be as light as possible, and second that it meet a stringent list of Military Specified requirements. The design team worked to extract every bit of weight from the design while striving to meet the rigorous Mil-Spec constraints. In the end compromises were made primarily on the specification side to control the overall weight of the transport case. This report outlines the case testing results.

  11. Electrical test prediction using hybrid metrology and machine learning

    Science.gov (United States)

    Breton, Mary; Chao, Robin; Muthinti, Gangadhara Raja; de la Peña, Abraham A.; Simon, Jacques; Cepler, Aron J.; Sendelbach, Matthew; Gaudiello, John; Emans, Susan; Shifrin, Michael; Etzioni, Yoav; Urenski, Ronen; Lee, Wei Ti

    2017-03-01

    Electrical test measurement in the back-end of line (BEOL) is crucial for wafer and die sorting as well as comparing intended process splits. Any in-line, nondestructive technique in the process flow to accurately predict these measurements can significantly improve mean-time-to-detect (MTTD) of defects and improve cycle times for yield and process learning. Measuring after BEOL metallization is commonly done for process control and learning, particularly with scatterometry (also called OCD (Optical Critical Dimension)), which can solve for multiple profile parameters such as metal line height or sidewall angle and does so within patterned regions. This gives scatterometry an advantage over inline microscopy-based techniques, which provide top-down information, since such techniques can be insensitive to sidewall variations hidden under the metal fill of the trench. But when faced with correlation to electrical test measurements that are specific to the BEOL processing, both techniques face the additional challenge of sampling. Microscopy-based techniques are sampling-limited by their small probe size, while scatterometry is traditionally limited (for microprocessors) to scribe targets that mimic device ground rules but are not necessarily designed to be electrically testable. A solution to this sampling challenge lies in a fast reference-based machine learning capability that allows for OCD measurement directly of the electrically-testable structures, even when they are not OCD-compatible. By incorporating such direct OCD measurements, correlation to, and therefore prediction of, resistance of BEOL electrical test structures is significantly improved. Improvements in prediction capability for multiple types of in-die electrically-testable device structures is demonstrated. To further improve the quality of the prediction of the electrical resistance measurements, hybrid metrology using the OCD measurements as well as X-ray metrology (XRF) is used. Hybrid metrology

  12. Comparison between Genetic Algorithms and Particle Swarm Optimization Methods on Standard Test Functions and Machine Design

    DEFF Research Database (Denmark)

    Nica, Florin Valentin Traian; Ritchie, Ewen; Leban, Krisztina Monika

    2013-01-01

    , genetic algorithm and particle swarm are shortly presented in this paper. These two algorithms are tested to determine their performance on five different benchmark test functions. The algorithms are tested based on three requirements: precision of the result, number of iterations and calculation time......Nowadays the requirements imposed by the industry and economy ask for better quality and performance while the price must be maintained in the same range. To achieve this goal optimization must be introduced in the design process. Two of the best known optimization algorithms for machine design....... Both algorithms are also tested on an analytical design process of a Transverse Flux Permanent Magnet Generator to observe their performances in an electrical machine design application....

  13. Fracture tests of etched components using a focused ion beam machine

    Science.gov (United States)

    Kuhn, Jonathan L.; Fettig, Rainer K.; Moseley, Samuel H., Jr.; Kutyrev, Alexander S.; Orloff, Jon

    2000-08-01

    Many optical MEMS device designs involve large arrays of thin (0.5 to 1 (mu) m) components subjected to high stresses due to cyclic loading. These devices are fabricated from a variety of materials, and the properties strongly depend on size and processing. Our objective is to develop standard and convenient test methods that can be used to measure the properties of large numbers of witness samples, for every device we build. In this work we explore a variety of fracture tests configurations for 0.5 (mu) m thick silicon nitride membranes machined using the Reactive Ion Etching (RIE) process. Testing was completed using an FEI 620 dual focused ion beam milling machine. Static loads were applied using a probe, and dynamic loads were applied through a piezo-electric stack mounted at the base of the probe. Results from the tests are presented and compared, and application for predicting fracture probability of large arrays of devices are considered.

  14. Comparison between Genetic Algorithms and Particle Swarm Optimization Methods on Standard Test Functions and Machine Design

    DEFF Research Database (Denmark)

    Nica, Florin Valentin Traian; Ritchie, Ewen; Leban, Krisztina Monika

    2013-01-01

    , genetic algorithm and particle swarm are shortly presented in this paper. These two algorithms are tested to determine their performance on five different benchmark test functions. The algorithms are tested based on three requirements: precision of the result, number of iterations and calculation time......Nowadays the requirements imposed by the industry and economy ask for better quality and performance while the price must be maintained in the same range. To achieve this goal optimization must be introduced in the design process. Two of the best known optimization algorithms for machine design....... Both algorithms are also tested on an analytical design process of a Transverse Flux Permanent Magnet Generator to observe their performances in an electrical machine design application....

  15. ENRtool - BesTest results

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne

    2007-01-01

    Test af beregninger gennemført med ENRtool over for BesTest valideringen under klimatiske forhold for Denver, Colorado.......Test af beregninger gennemført med ENRtool over for BesTest valideringen under klimatiske forhold for Denver, Colorado....

  16. Testing of machinability of mould steel 40CrMnMo7 using genetic algorithm

    OpenAIRE

    Stoić, Antun; Cukor, Goran; Kopač, Janez

    2015-01-01

    This paper deals with testing of hard materials machinability by high speed turning process and influence of cutting parameters on machinability rates. Todetermine machinability rates, surface roughness, tool wear and cutting force components were measured. In accordance with expected influence of certain parameter on machinability, experiments were designed and performed todetermine mathematical models of the measured values over full response range. Obtained mathematical models were used fo...

  17. Fabrication and test of an axial-field HTS rotating machine with integrated magnetic coupling

    Science.gov (United States)

    Dolisy, B.; Mezani, S.; Lubin, T.; Lévêque, J.

    2017-03-01

    High temperature superconducting (HTS) electrical machines have high torque density with a very high efficiency. Torque tubes are usually used to transmit the torque from the cold to the warm environment which results in thermal losses and mechanical problems. To overcome these difficulties, we propose to transmit the torque of the HTS machine through an integrated HTS magnetic coupling. A prototype has been constructed and tested showing the effectiveness of the proposed solution. The machine and the coupling share the same HTS rotor while the torque produced by the machine is transmitted to the load via a permanent magnets rotor. This solution allows the reduction of the thermal losses and a natural protection against overload during fault. The electromagnetic design is carried out using 3D finite elements (FE). The HTS material electrical behavior is described using a power law so it was possible to determine the operating current of the HTS coils of the device. Many test results such as U(I) curves of the HTS coils, static torque, back-EMF and on-load characteristics are presented and checked by the FE computations.

  18. Software Development for Digital Control of WDW Series Testing Machine and Measurement of KIC

    Institute of Scientific and Technical Information of China (English)

    黄兴; 马杭; 程昌钧

    2005-01-01

    Software has been developed for digital control of WDW series testing machine and the measurement of fracture toughness by modularized design. Development of the software makes use of multi-thread and serial communication techniques, which can accurately control the testing machine and measure the fracture toughness in real-time. Three-point bending specimens were used in the measurement. The software operates stably and reliably, expanding the function of WDW series testing machine.

  19. Test Results for CSTR Test 4

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D.D.

    2001-05-31

    One of the 3 technologies currently being developed for the Savannah River Salt Waste Processing Program is the Small-Tank Tetraphenylborate Process (STTP). This process uses sodium tetraphenylborate to precipitate and remove radioactive Cs from the waste and monosodium titanate to sorb and remove radioactive Sr and actinides. ORNL is demonstrating this process at the 1:4000 scale using a 20-liter continuous-flow stirred tank reactor (CSTR) system. The primary goal of Test 4 was to verify that the STTP process could achieve and maintain the necessary Cs decontamination while TPB was actively decomposing. Even with TPB being decomposed by the off-normal conditions of this test, the decontaimination factor for {sup 137}Cs obtained for the filtrate from the Slurry Concentrating Tank ranged from 47,000 to 646,000, exceeding the WAC standard.

  20. FIRST RESULTS FROM OEDOTENSIOMETRIC TESTS

    Directory of Open Access Journals (Sweden)

    Luigi Cavazza

    2008-09-01

    Full Text Available An oedotensiometer was used to examine to examine the behaviour of sieved sample of a swelling soil (a vertisol as well as of the same soils treated with solution of Na+ + Ca2+ to simulate the soil changes from excessive irrigation with brackish water. The oedometer test consisted in an infiltration of water from below through a ceramic porous plate at a feeding pressure of +10 cm water and successive drainage under a depression mostly of -112 cm of water. The rate of water entry as well as the swelling rate of the sample were monitored. Preliminary considerations regards the domains in which the shrinkage curve of a swelling soil is subdivided and make hypothesis on the swelling process expected when the infiltration from below of the sample is applied. The results support the hypothesis that when the water pressure is applied some water enters rather rapidly in the larger structural pores and is followed later by the swelling in the smaller pores, responsible for the basic domain. This first conclusion demonstrates that the assumption of a simultaneous movement of solid and liquid components in the sample, which is the base of most theoretical developments for swelling soils, cannot be accepted for the tested samples. Some cases with water clogging on the sample surface confirm a late final swelling of the soil and permitted to evaluate the hydraulic conductivity of the swollen soil. These manifestations are more evident in sodicated soils. The loading of the sample reduces the swelling of the sample and seems to reduce its permeability. The reduction of the feeding water pressure further reduces the sample swelling. The draining process from saturated soil sample shows that most of the process occurs in the large pores of the structural domain. This gives the possibility to evaluate the water diffusivity coefficient for the structural domain of the sample. In draining the soil with the highest sodication there was a variation of soil volume

  1. Results of Aluminosilicate Inhibitor Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wilmarth, W.R.

    2001-06-27

    The aluminosilicate scale in the 2H Evaporator has precluded operation since late 1999. The chemistry of scale formation is known but the mechanism(s) for deposition are not well understood. Tests have been conducted to determine if chemical agents could prevent aluminosilicate formation under conditions similar to Tank 43H. Additionally, particle growth inhibition is also tested.

  2. The Insulation for Machines Having a High Lifespan Expectancy, Design, Tests and Acceptance Criteria Issues

    Directory of Open Access Journals (Sweden)

    Olivier Barré

    2017-02-01

    Full Text Available The windings insulation of electrical machines will remain a topic that is updated frequently. The criteria severity requested by the electrical machine applications increases continuously. Manufacturers and designers are always confronted with new requirements or new criteria with enhanced performances. The most problematic requirements that will be investigated here are the extremely long lifespan coupled to critical operating conditions (overload, supply grid instabilities, and critical operating environments. Increasing lifespan does not have a considerable benefit because the purchasing price of usual machines has to be compared to the purchasing price and maintenance price of long lifespan machines. A machine having a 40-year lifespan will cost more than twice the usual price of a 20-year lifetime machine. Systems which need a long lifetime are systems which are crucial for a country, and those for which outage costs are exorbitant. Nuclear power stations are such systems. It is certain that the used technologies have evolved since the first nuclear power plant, but they cannot evolve as quickly as in other sectors of activities. No-one wants to use an immature technology in such power plants. Even if the electrical machines have exceeded 100 years of age, their improvements are linked to a patient and continuous work. Nowadays, the windings insulation systems have a well-established structure, especially high voltage windings. Unfortunately, a high life span is not only linked to this result. Several manufacturers’ improvements induced by many years of experiment have led to the writing of standards that help the customers and the manufacturers to regularly enhance the insulation specifications or qualifications. Hence, in this publication, the authors will give a step by step exhaustive review of one insulation layout and will take time to give a detailed report on the standards that are linked to insulation systems. No standard can

  3. Numerical Modeling of Dual-Pulse Shock Test Machine for Simulating Underwater Explosion Shock Loads on Warship Equipments

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhi-yi; WANG Gong-xian; WANG Yu

    2009-01-01

    In order to qualify shock resistance performance of shipboard equipments and simulate real underwater explosion environment, a novel dual-puise shock test machine is proposed. The new machine will increase testing capability and meet special shock testing requirement. Two key parts of the machine, the velocity generator and the shock pulse regulator, play an important role in producing the positive acceleration pulse and the succeeding negative acceleration pulse, respectively. The generated dual-pulse shock for test articles is in conformity with an anti-shock test specification. Based on the impact theory, a nonlinear dynamic model of the hydraulically-actuated test machine is established with thorough analysis on its mechanism that involves conversion of gas potential energy and dissipation of kinetic energy. Simulation results have demonstrated that the proposed machine is able to produce a double-pulse acceleration shock in the time domain or a desired shock response spectrum in the frequency domain, which sets up a base for the construction of the machine.

  4. Chemical compatibility screening test results

    Energy Technology Data Exchange (ETDEWEB)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60{degrees}C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m{sup 2} for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals.

  5. MACHINING TEST SPECIMENS FROM HARVESTED ZION RPV SEGMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Nanstad, Randy K [ORNL; Rosseel, Thomas M [ORNL; Sokolov, Mikhail A [ORNL

    2015-01-01

    The decommissioning of the Zion Nuclear Generating Station (NGS) in Zion, Illinois, presents a special and timely opportunity for developing a better understanding of materials degradation and other issues associated with extending the lifetime of existing nuclear power plants (NPPs) beyond 60 years of service. In support of extended service and current operations of the US nuclear reactor fleet, the Oak Ridge National Laboratory (ORNL), through the Department of Energy (DOE), Light Water Reactor Sustainability (LWRS) Program, is coordinating and contracting with Zion Solutions, LLC, a subsidiary of Energy Solutions, an international nuclear services company, the selective procurement of materials, structures, components, and other items of interest from the decommissioned reactors. In this paper, we will discuss the acquisition of segments of the Zion Unit 2 Reactor Pressure Vessel (RPV), cutting these segments into blocks from the beltline and upper vertical welds and plate material and machining those blocks into mechanical (Charpy, compact tension, and tensile) test specimens and coupons for microstructural (TEM, SEM, APT, SANS and nano indention) characterization. Access to service-irradiated RPV welds and plate sections will allow through wall attenuation studies to be performed, which will be used to assess current radiation damage models [1].

  6. Ultrasonic Transducer Irradiation Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Palmer, Joe [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Keller, Paul [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Montgomery, Robert [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chien, Hual-Te [Argonne National Lab. (ANL), Argonne, IL (United States); Kohse, Gordon [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States); Tittmann, Bernhard [Pennsylvania State Univ., University Park, PA (United States); Reinhardt, Brian [Pennsylvania State Univ., University Park, PA (United States); Rempe, Joy [Rempe and Associates, Idaho Falls, ID (United States)

    2015-02-01

    Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric

  7. Construction and validation tests of a micro-impression creep test machine

    Directory of Open Access Journals (Sweden)

    KANG JUNG

    2014-12-01

    Full Text Available A micro-impression creep machine was designed and developed, adopting a small punch in diameter of 150 um, displacement gage with sub-μm-scale accuracy, and a load-cell with mN-scale accuracy of in an effort to investigate the creep behavior of a small solder ball with a diameter of less than 1 mm. The creep behavior of a lead-free solder ball (Sn-3.0Ag-0.5Cu with a diameter of 760 μm was investigated in the stress range of 8 to 60MPa and in the temperature range of 303K to 393K. We verified the appropriate performance of the developed machine by comparing the creep data from the self-made testing device to previously reported data for a magnesium alloy (AZ31. The stress exponent n for the solder ball sample was 3.7 in an intermediate stress range at 348K, indicating that glide of dislocations dragging in a solute atmosphere is the dominant creep deformation mechanism. The developed testing machine can be expected to find use in evaluating the creep strength of microelectronic solder joints.

  8. Equipped Search Results Using Machine Learning from Web Databases

    Directory of Open Access Journals (Sweden)

    Ahmed Mudassar Ali

    2015-05-01

    Full Text Available Aim of this study is to form a cluster of search results based on similarity and to assign meaningful label to it Database driven web pages play a vital role in multiple domains like online shopping, e-education systems, cloud computing and other. Such databases are accessible through HTML forms and user interfaces. They return the result pages come from the underlying databases as per the nature of the user query. Such types of databases are termed as Web Databases (WDB. Web databases have been frequently employed to search the products online for retail industry. They can be private to a retailer/concern or publicly used by a number of retailers. Whenever the user queries these databases using keywords, most of the times the user will be deviated by the search results returned. The reason is no relevance exists between the keyword and SRs (Search Results. A typical web page returned from a WDB has multiple Search Result Records (SRRs. An easier way is to group the similar SRRs into one cluster in such a way the user can be more focused on his demand. The key concept of this paper is XML technologies. In this study, we propose a novel system called CSR (Clustering Search Results which extracts the data from the XML database and clusters them based on the similarity and finally assigns meaningful label for it. So, the output of the keyword entered will be the clusters containing related data items.

  9. Secure State UML: Modeling and Testing Security Concerns of Software Systems Using UML State Machines

    Directory of Open Access Journals (Sweden)

    S. Batool

    2014-05-01

    Full Text Available In this research we present a technique by using which, extended UML models can be converted to standard UML models so that existing MBT techniques can be applied directly on these models. Existing Model Based Testing (MBT Techniques cannot be directly applied to extended UML models due to the difference of modeling notation and new model elements. Verification of these models is also very important. Realizing and testing non functional requirements such as efficiency, portability and security, at model level strengthens the ability of model to turn down risk, cost and probability of system failure in cost effective way. Access control is most widely used technique for implementing security in software systems. Existing approaches for security modeling focus on representation of access control policies such as authentication, role based access control by introducing security oriented model elements through extension in Unified Modelling Language (UML. But doing so hinders the potential and application of MBT techniques to verify these models and test access control policies. In this research we introduce a technique secure State UML to formally design security models with secure UML and then transform it to UML state machine diagrams so that it can be tested, verified by existing MBT techniques. By applying proposed technique on case studies, we found the results that MBT techniques can be applied on resulting state machine diagrams and generated test paths have potential to identify the risks associated with security constraints violation.

  10. Flexible Ablators Char Depths LHMEL Test Results

    Science.gov (United States)

    White, Susan; Qu, Vince; Fan, Wendy; Stackpoole, Mairead; Thornton, Jeremy

    2012-01-01

    Char and pyrolysis zone depths give physical evidence of peak temperature reached in depth: The pyrolyzing material acts as a temperature indicator within its characteristic thermal decomposition range. A matrix of novel flexible ablators were laser tested in one component of material screening for NASA Entry, Descent and Landing research for future Mars missions. LHMEL tests were run both on virgin materials, and on previously charred materials for a dual pulse simulation of the heating due to aerocapture followed by atmospheric entry. The test models were machined to expose the cross-sections. Char measurements were made at three locations near the center of the exposed area. Data are presented showing the char depths developed in these flexible materials, grouped by reinforcing fiber and pyrolyzing material type.

  11. 40 CFR 799.12 - Test results.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...

  12. Tests of Lead-bronze Bearings in the DVL Bearing-testing Machine

    Science.gov (United States)

    Fischer, G

    1940-01-01

    The lead-bronze bearings tested in the DVL machine have proven themselves very sensitive to load changes as in comparison with bearings of light metal. In order to prevent surface injuries and consequently running interruptions, the increase of the load has to be made in small steps with sufficient run-in time between steps. The absence of lead in the running surface, impurities in the alloy (especially iron) and surface irregularities (pores) decreases the load-carrying capacity of the bearing to two or three times that of the static load.

  13. XML related data exchange from the test machine to a web-enabled MAT-DB

    Directory of Open Access Journals (Sweden)

    M Nagy

    2006-01-01

    Full Text Available One of the JRC Petten tasks is to support European Research and Development (R&D projects in the material and energy related areas with the management and dissemination of research results. By using XML technology test data can be entered directly from the test machines into the Web-enabled 'Materials Database' (Mat-DB, which is an integral part of the On-line Data Information Network (ODIN On-line Data Information Network, 2004 that has been developed at JRC Petten. Test data, which are kept in XML format and sent by R&D project partners via the World Wide Web to the Petten Server are stored within the Mat-DB XML module. There they can be checked and updated on-line before they are uploaded into the database. After validation by the source administrator they can immediately be retrieved and evaluated by all project partners. A pilot test with the new XML related data exchange module from test machine into Mat-DB has currently been started within the European TMF Standard R&D project.

  14. Testing and modeling of Losses in Induction Machines%感应电机损耗测试与建模

    Institute of Scientific and Technical Information of China (English)

    丁晓峰; 刘景林

    2011-01-01

    Experimental testing and 2 - D finite element (FE) modeling of losses in induction machines are presented in this paper. Firstly, the experimental bench is set up, to test the losses of induction machines.The windage & friction loss, copper loss and iron loss are measured when the machine is without-load and driven by 3 - phase sinusoidal supply. Based on the results of the test, a more accurate 2 - D FE model of losses for induction machine is developed. And the losses in the induction machine are predicted and measured by the model and experimental bench respectively when the loaded machine is driven by sinusoidal supply and the without-load/loaded machine is driven by PWM supply. Furthermore, the experimental results are found to be consistent with the results from simulation.%该文针对感应电机损耗进行实验测试和2D有限元建模.首先搭建了感应电机损耗测试的实验平台,在三相正弦波驱动电机的情况下,测得电机空载时的风阻与摩擦损耗、铜损耗以及铁损耗.根据实验测试结果,建立了较精确的感应电机损耗2D有限元模型.在三相正弦波电源驱动负载电机和PWM波电源驱动空载/负载电机时,利用该有限元仿真模型和实验平台分别计算和测试了电机各种损耗.实验结果有效地证实了仿真模型的正确性.

  15. Dynamic Characteristics of a New Machine for Fatigue Testing of Railway Axles – Part 2

    Directory of Open Access Journals (Sweden)

    Karel FRYDRÝŠEK

    2012-06-01

    Full Text Available There were done some proposal calculations for a new testing machine. This new testing machine is determined for a dynamic fatigue testing of railway axles. The railway axles are subjected to bending and rotation (centrifugal effects. For the right proposition of a new machine is very important to know the basic dynamic characteristics of whole system. These dynamic characteristics are solved via FEM (MSC.Marc/Mentat software in combination with SBRA (Simulation-Based Reliability Assessment Method (probabilistic Monte Carlo approach, Anthill and Python software. The proposed dimensions and springs of a new machine for fatigue testing of railway axles were used for manufacturing. Application of the SBRA method connected with FEM in these areas is a new and innovative trend in mechanics. This paper is continuation of former work (i.e. easier deterministic approach already presented in this journal in 2007.

  16. Development of testing machine for tunnel inspection using multi-rotor UAV

    Science.gov (United States)

    Iwamoto, Tatsuya; Enaka, Tomoya; Tada, Keijirou

    2017-05-01

    Many concrete structures are deteriorating to dangerous levels throughout Japan. These concrete structures need to be inspected regularly to be sure that they are safe enough to be used. The inspection method for these concrete structures is typically the impact acoustic method. In the impact acoustic method, the worker taps the surface of the concrete with a hammer. Thus, it is necessary to set up scaffolding to access tunnel walls for inspection. Alternatively, aerial work platforms can be used. However, setting up scaffolding and aerial work platforms is not economical with regard to time or money. Therefore, we developed a testing machine using a multirotor UAV for tunnel inspection. This test machine flies by a plurality of rotors, and it is pushed along a concrete wall and moved by using rubber crawlers. The impact acoustic method is used in this testing machine. This testing machine has a hammer to make an impact, and a microphone to acquire the impact sound. The impact sound is converted into an electrical signal and is wirelessly transmitted to the computer. At the same time, the position of the testing machine is measured by image processing using a camera. The weight and dimensions of the testing machine are approximately 1.25 kg and 500 mm by 500 mm by 250 mm, respectively.

  17. ON-LINE SELF-TESTING FOR MICRO-MACHINED GYROSCOPES

    Institute of Scientific and Technical Information of China (English)

    GAISSERAlexander; GAOZhong-yu; ZHANGRong; CHENZhi-yong; ZHOUBin

    2005-01-01

    An on line self-testing for Coriolis vibratory gyroscopes (CVGs) is realized according to a digital readout electronics for capacitive sensors and micro-machined angular rate sensors. By applying some additional signals to the micro machined structure, the actual noise performance (<0.1°/s) is not worsened. The running of the primary and the secondary oscillators of CVGs is verified by self-testing. Compared with other methods, the device needs not to check the functionality. In this new approach the on-line testing is conducted at any time without disturbing the normal operational mode. Based on the approach the performance of the micro machined gyroscope can be improved and a secure availability of the functionality of the micro-machined angular rate sensor is guaranteed. Furthermore, the error signal is generated when the sensor works incorrectly.

  18. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • ...

  19. Common Diagnostic Test Results Over the Years

    Directory of Open Access Journals (Sweden)

    Aruvee Eve

    2016-12-01

    Full Text Available In this article, common test results over the years 2000 – 2016 are analysed. The test questions for new entrants were based on secondary school mathematics. The students took the test in the first lesson of the higher mathematics course. The test results were analysed by years, by tasks and by specialities, and their differences were found. The test results’ dependence on state-exams score was studied and other types of dependence were looked at.

  20. Unconstrained testing of spine with bi-axial universal testing machine.

    Science.gov (United States)

    Inceoğlu, Serkan; Chen, Justin; Cale, Hayden; Harboldt, Bjorn; Cheng, Wayne K

    2015-10-01

    In-vitro biomechanical assessment of the spine reveals significant information on the mechanics of spinal disorders, treatment methods, and surgical implants. Specialized devices for the evaluation of spine biomechanics have thus become popular. However, these devices might not be affordable for all research groups. The purpose of this study was to describe an apparatus to be attached to a standard bi-axial universal testing machine that would make unconstrained testing of the spine possible. A technical note on the definition of a spinal testing fixture with validation. Intact lumbosacral spines (T12-S1) were tested in sagittal and lateral bending and axial rotation. Three-dimensional interlevel rotations at each level (L1-4) were analyzed. By comparison with the literature, we found that the new fixture was able to successfully produce reasonable relative rotation values for the lumbar spine. We demonstrated that the low cost fixture allowed unconstrained (six degree of freedom, 6 DOF) testing of fresh-frozen cadaveric lumbar spine. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. An experimental result of surface roughness machining performance in deep hole drilling

    Directory of Open Access Journals (Sweden)

    Mohamad Azizah

    2016-01-01

    Full Text Available This study presents an experimental result of a deep hole drilling process for Steel material at different machining parameters which are feed rate (f, spindle speed (s, the depth of the hole (d and MQL, number of drops (m on surface roughness, Ra. The experiment was designed using two level full factorial design of experiment (DoE with centre points to collect surface roughness, Ra values. The signal to noise (S/N ratio analysis was used to discover the optimum level for each machining parameters in the experiment.

  2. Interactive Diagnostic Testing: Field Trial Results.

    Science.gov (United States)

    McArthur, David L.; Cabello, Beverly

    A diagnostic testing system managed by microcomputer was evaluated in actual use at the upper elementary level. Two tests specifically designed to yield diagnostic indicators of erroneous performance were utilized, one a test of pronoun usage, the other a test of reading comprehension. The results are interpreted from the standpoint of the…

  3. Improving Non-Destructive Concrete Strength Tests Using Support Vector Machines.

    Science.gov (United States)

    Shih, Yi-Fan; Wang, Yu-Ren; Lin, Kuo-Liang; Chen, Chin-Wen

    2015-10-22

    Non-destructive testing (NDT) methods are important alternatives when destructive tests are not feasible to examine the in situ concrete properties without damaging the structure. The rebound hammer test and the ultrasonic pulse velocity test are two popular NDT methods to examine the properties of concrete. The rebound of the hammer depends on the hardness of the test specimen and ultrasonic pulse travelling speed is related to density, uniformity, and homogeneity of the specimen. Both of these two methods have been adopted to estimate the concrete compressive strength. Statistical analysis has been implemented to establish the relationship between hammer rebound values/ultrasonic pulse velocities and concrete compressive strength. However, the estimated results can be unreliable. As a result, this research proposes an Artificial Intelligence model using support vector machines (SVMs) for the estimation. Data from 95 cylinder concrete samples are collected to develop and validate the model. The results show that combined NDT methods (also known as SonReb method) yield better estimations than single NDT methods. The results also show that the SVM model is more accurate than the statistical regression model.

  4. Improving Non-Destructive Concrete Strength Tests Using Support Vector Machines

    Directory of Open Access Journals (Sweden)

    Yi-Fan Shih

    2015-10-01

    Full Text Available Non-destructive testing (NDT methods are important alternatives when destructive tests are not feasible to examine the in situ concrete properties without damaging the structure. The rebound hammer test and the ultrasonic pulse velocity test are two popular NDT methods to examine the properties of concrete. The rebound of the hammer depends on the hardness of the test specimen and ultrasonic pulse travelling speed is related to density, uniformity, and homogeneity of the specimen. Both of these two methods have been adopted to estimate the concrete compressive strength. Statistical analysis has been implemented to establish the relationship between hammer rebound values/ultrasonic pulse velocities and concrete compressive strength. However, the estimated results can be unreliable. As a result, this research proposes an Artificial Intelligence model using support vector machines (SVMs for the estimation. Data from 95 cylinder concrete samples are collected to develop and validate the model. The results show that combined NDT methods (also known as SonReb method yield better estimations than single NDT methods. The results also show that the SVM model is more accurate than the statistical regression model.

  5. Ex vivo normothermic machine perfusion is safe, simple, and reliable: results from a large animal model.

    Science.gov (United States)

    Nassar, Ahmed; Liu, Qiang; Farias, Kevin; D'Amico, Giuseppe; Tom, Cynthia; Grady, Patrick; Bennett, Ana; Diago Uso, Teresa; Eghtesad, Bijan; Kelly, Dympna; Fung, John; Abu-Elmagd, Kareem; Miller, Charles; Quintini, Cristiano

    2015-02-01

    Normothermic machine perfusion (NMP) is an emerging preservation modality that holds the potential to prevent the injury associated with low temperature and to promote organ repair that follows ischemic cell damage. While several animal studies have showed its superiority over cold storage (CS), minimal studies in the literature have focused on safety, feasibility, and reliability of this technology, which represent key factors in its implementation into clinical practice. The aim of the present study is to report safety and performance data on NMP of DCD porcine livers. After 60 minutes of warm ischemia time, 20 pig livers were preserved using either NMP (n = 15; physiologic perfusion temperature) or CS group (n = 5) for a preservation time of 10 hours. Livers were then tested on a transplant simulation model for 24 hours. Machine safety was assessed by measuring system failure events, the ability to monitor perfusion parameters, sterility, and vessel integrity. The ability of the machine to preserve injured organs was assessed by liver function tests, hemodynamic parameters, and histology. No system failures were recorded. Target hemodynamic parameters were easily achieved and vascular complications were not encountered. Liver function parameters as well as histology showed significant differences between the 2 groups, with NMP livers showing preserved liver function and histological architecture, while CS livers presenting postreperfusion parameters consistent with unrecoverable cell injury. Our study shows that NMP is safe, reliable, and provides superior graft preservation compared to CS in our DCD porcine model. © The Author(s) 2014.

  6. Pavement Subgrade Performance Study in the Danish Road Testing Machine

    DEFF Research Database (Denmark)

    Ullidtz, Per; Ertman Larsen, Hans Jørgen

    1997-01-01

    Most existing pavement subgrade criteria are based on the AASHO Road Test, where only one material was tested and for only one climatic condition. To study the validity of these criteria and to refine the criteria a co-operative research program entitled the "International Pavement Subgrade Perfo...

  7. Construction and Analysis of Educational Tests Using Abductive Machine Learning

    Science.gov (United States)

    El-Alfy, El-Sayed M.; Abdel-Aal, Radwan E.

    2008-01-01

    Recent advances in educational technologies and the wide-spread use of computers in schools have fueled innovations in test construction and analysis. As the measurement accuracy of a test depends on the quality of the items it includes, item selection procedures play a central role in this process. Mathematical programming and the item response…

  8. Construction and Analysis of Educational Tests Using Abductive Machine Learning

    Science.gov (United States)

    El-Alfy, El-Sayed M.; Abdel-Aal, Radwan E.

    2008-01-01

    Recent advances in educational technologies and the wide-spread use of computers in schools have fueled innovations in test construction and analysis. As the measurement accuracy of a test depends on the quality of the items it includes, item selection procedures play a central role in this process. Mathematical programming and the item response…

  9. An Axial Sliding Test for machine elements surfaces

    DEFF Research Database (Denmark)

    Godi, Alessandro; Grønbæk, J.; Mohaghegh, Kamran

    2012-01-01

    liners. To prove the efficacy of a particular textured surface, it is paramount to perform experimental tests under controlled laboratory conditions. In this paper a new test rig simulating pure sliding conditions is presented, dubbed Axial Sliding Test. It presents four major components: a rod, a sleeve......, a housing and a stripwound container. The rod and the sleeve are the two surfaces in relative sliding motion; the stripwound container maintains a constant, but adjustable normal pressure and the housing serves as interface between the sleeve and the container. For carrying out the test, two machineries...... turned rod against a mirror-polished sleeve. Qualitatively the multifunctional surfaces improve the friction conditions, but a more structured test campaign is required....

  10. Improving fault coverage and minimising the cost of fault identification when testing from finite state machines

    OpenAIRE

    Guo, Qiang

    2006-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. Software needs to be adequately tested in order to increase the confidence that the system being developed is reliable. However, testing is a complicated and expensive process. Formal specification based models such as finite state machines have been widely used in system modelling and testing. In this PhD thesis, we primarily investigate fault detection and identification when testing from f...

  11. Neuropsychological test selection for cognitive impairment classification: A machine learning approach.

    Science.gov (United States)

    Weakley, Alyssa; Williams, Jennifer A; Schmitter-Edgecombe, Maureen; Cook, Diane J

    2015-01-01

    Reducing the amount of testing required to accurately detect cognitive impairment is clinically relevant. The aim of this research was to determine the fewest number of clinical measures required to accurately classify participants as healthy older adult, mild cognitive impairment (MCI), or dementia using a suite of classification techniques. Two variable selection machine learning models (i.e., naive Bayes, decision tree), a logistic regression, and two participant datasets (i.e., clinical diagnosis; Clinical Dementia Rating, CDR) were explored. Participants classified using clinical diagnosis criteria included 52 individuals with dementia, 97 with MCI, and 161 cognitively healthy older adults. Participants classified using CDR included 154 individuals with CDR = 0, 93 individuals with CDR = 0.5, and 25 individuals with CDR = 1.0+. A total of 27 demographic, psychological, and neuropsychological variables were available for variable selection. No significant difference was observed between naive Bayes, decision tree, and logistic regression models for classification of both clinical diagnosis and CDR datasets. Participant classification (70.0-99.1%), geometric mean (60.9-98.1%), sensitivity (44.2-100%), and specificity (52.7-100%) were generally satisfactory. Unsurprisingly, the MCI/CDR = 0.5 participant group was the most challenging to classify. Through variable selection only 2-9 variables were required for classification and varied between datasets in a clinically meaningful way. The current study results reveal that machine learning techniques can accurately classify cognitive impairment and reduce the number of measures required for diagnosis.

  12. Instrumented impact testing machine with reduced specimen oscillation effects

    Science.gov (United States)

    Rintamaa, R.; Ranka, K.; Wallin, K.; Ikonen, K.; Talja, H.; Kotilainen, H.; Sirkkola, E.

    1984-07-01

    A pendulum-type instrumented Charpy test apparatus based on inverted test geometry was developed. Geometry inversion reduces inertia load and specimen oscillation effects. Initial impact energy is double that of standard (300 J) impact testers, allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. The rotation axis in the three point bending is nearly stationary, making COD-measurements possible. Inertia effects and specimen oscillations are compared with the conventional tester, and using an analytical finite element model for Charpy V-notch specimens. Better performance for the inverted geometry is reported.

  13. Design and production of a novel sand materials strength testing machine for foundry applications

    DEFF Research Database (Denmark)

    Nwaogu, Ugochukwu Chibuzoh; Hansen, K. S.; Tiedje, Niels Skat

    2012-01-01

    testing machine was designed and built for both green sand and chemically-bonded sand materials. This machine measures and presents the loading response as a force-displacement profile from which the mechanical properties of the moulding materials can be deduced. The system was interfaced to a computer...... with a commercial PC based-control and data acquisition software. The testing conditions and operations are specified in the user interface and the data acquisition is made according to specifications. The force and displacements were calibrated to ensure consistency and reliability of the measurement data...

  14. Reproducibility of AMPLICOR enterovirus PCR test results.

    OpenAIRE

    1997-01-01

    The reproducibility of AMPLICOR enterovirus PCR test results was determined with clinical samples of cerebrospinal fluid, serum, urine, and throat and rectal swabs. Among 608 samples from which duplicate aliquots were run simultaneously, only seven pairs gave discordant results. Among 104 samples from which duplicate aliquots were run in separate assays, no discordance was seen. Overall, the reproducibility of test kit results was 99% (705 of 712).

  15. Production LHC HTS power lead test results

    CERN Document Server

    Tartaglia, M; Fehér, S; Huang, Y; Orris, D F; Pischalnikov, Y; Rabehl, Roger Jon; Sylvester, C D; Zbasnik, J

    2005-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under "standard" and "extreme" operating conditions, and the stability of performance across thermal cycles.

  16. Support-Vector-Machine-Based False Alarm Filter of Mechatronic Built-in Test

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Diagnosing intermittent fault is an important approach to reduce built-in test (BIT) false alarms. Aiming at solving the shortcoming of the present diagnostic method of intermittent fault, and according to the merit of support vector machines ( SVM) which can be trained with a small-sample, an SVM-based diagnostic model of 3 states that include OK state, intermittent state and faulty state is presented. With the features based on the reflection coefficients of an alarm rate(AR) model extracted from small vibration samples, these models are trained to diagnose intermittent faults. The experimental results show that this method can diagnose multiple intermittent faults accurately with small training samples and BIT false alarms are reduced.

  17. Some considerations concerning four-ball machine testing of the polyacrylamide solutions

    Science.gov (United States)

    Drumeanu, A. C.

    2017-02-01

    Polyacrylamide (PAM) is one of the most widely used and technically important water-soluble polymers. Polyacrylamide (PAM) is usually obtained by free radical polymerization of acrylamide (AM) and in its partially hydrolysed form is a synthetic straight-chain polymer of acrylamide monomers, some of which have been hydrolysed. The structure of HPAM molecule is a flexible chain. This kind of structure is known as a random coil in polymer chemistry. Due to the hydrolysed groups contained in its molecule, HPAM has multiple charges distributed along the chain that make it a polyelectrolyte. The paper presents the experimental results concerning the lubricant solutions based on polyacrylamide behaviour when were tested on the four ball machine. It has to be mentioned that this kind of polymer was not used until now in lubrication and the studies concerning its tribological behaviour are at the beginning.

  18. The use of new in-situ test machine to evaluate the shear strength of asphalt layers

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Nabi, R.M.; Abdel Halim, A.O. [Carleton Univ., Ottawa, ON (Canada). Dept. of Civil and Environmental Engineering; Abdel Aleem, A.M. [Zagazig University, (Egypt); El Hussein, H.M. [National Research Council of Canada, Ottawa, ON (Canada)

    1995-12-31

    The development of the first in-situ shear test machine designed to determine the shear strength of asphalt layers in the field, was described. A total of 76 shear tests were performed. The in-situ test results showed more consistency than the test results obtained from laboratory tests. This would imply that field coring, or disturbing asphalt layers in the field before testing may, in fact, induce damage to the test samples, resulting in underestimating the actual strength of the pavement structure. A comparison between between field and laboratory results showed that the laboratory shear strength was significantly lower than the one measured in the field. 9 refs., 5 tabs., 3 figs.

  19. Using Test Results to Improve Instruction.

    Science.gov (United States)

    Bassler, Otto C.; Caulkins, Thomas G.

    A model for summarizing test scores and using them to modify instructional programs is presented. The proposed model consists of two types of summaries of the data gathered through standardized tests. The first summary contains individual and single class results. Information in a "Class Item Response Record" chart provides individual student…

  20. Results of the HESSI Test Mishap Investigation

    Science.gov (United States)

    Worth, Daniel B.; Phillips, Rodney N.; Kross, Dennis A. (Technical Monitor)

    2000-01-01

    On March 21, 2000, the High-Energy Solar Spectroscopic Imager (HESSI) spacecraft was subjected to a series of vibration tests at the Jet Propulsion Laboratory (JPL) as a part of its flight certification program. The structural qualification test, denoted as the sineburst test, subjected the spacecraft to a major overtest that resulted in significant structural damage to the spacecraft. The HESSI Test Mishap Investigation Board (MIB) was formed on March 24, 2000, in response to a NASA headquarters request. Board membership included experts from NASA and the University of California at Berkeley. This paper will present the investigation methods, findings, and lessons learned from the HESSI mishap.

  1. Dynamic Tensile Test Results for Several Metals

    Science.gov (United States)

    1982-04-01

    8217• AFWAL-TR-82-4026 SDYNAMIC TENSILE TEST RESULTS FOR SEVERAL METALS SUNIVERSITY OF DAYTON RESEA CH INSTITUTE ’ 300 COLLEGE PARK DR. DAYTON, OHIO... Tensile Test Results for March - September 1981 Several Metals 6. PERFORMING oDG. REPORT NUMBER UDR-TR-82-05 7. AUTHOR(s) S. CONTRACT OfR GRANT NUMBER(&) S...tensile stresses above 10 s The split Hopkinson bar tensile test (see next section) can extend this range another decade. Resolution of rapidly

  2. The Aachen miniaturized heart-lung machine--first results in a small animal model.

    Science.gov (United States)

    Schnoering, Heike; Arens, Jutta; Sachweh, Joerg S; Veerman, Melanie; Tolba, Rene; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Vazquez-Jimenez, Jaime F

    2009-11-01

    Congenital heart surgery most often incorporates extracorporeal circulation. Due to foreign surface contact and the administration of foreign blood in many children, inflammatory response and hemolysis are important matters of debate. This is particularly an issue in premature and low birth-weight newborns. Taking these considerations into account, the Aachen miniaturized heart-lung machine (MiniHLM) with a total static priming volume of 102 mL (including tubing) was developed and tested in a small animal model. Fourteen female Chinchilla Bastard rabbits were operated on using two different kinds of circuits. In eight animals, a conventional HLM with Dideco Kids oxygenator and Stöckert roller pump (Sorin group, Milan, Italy) was used, and the Aachen MiniHLM was employed in six animals. Outcome parameters were hemolysis and blood gas analysis including lactate. The rabbits were anesthetized, and a standard median sternotomy was performed. The ascending aorta and the right atrium were cannulated. After initiating cardiopulmonary bypass, the aorta was cross-clamped, and cardiac arrest was induced by blood cardioplegia. Blood samples for hemolysis and blood gas analysis were drawn before, during, and after cardiopulmonary bypass. After 1 h aortic clamp time, all animals were weaned from cardiopulmonary bypass. Blood gas analysis revealed adequate oxygenation and perfusion during cardiopulmonary bypass, irrespective of the employed perfusion system. The use of the Aachen MiniHLM resulted in a statistically significant reduced decrease in fibrinogen during cardiopulmonary bypass. A trend revealing a reduced increase in free hemoglobin during bypass in the MiniHLM group could also be observed. This newly developed Aachen MiniHLM with low priming volume, reduced hemolysis, and excellent gas transfer (O(2) and CO(2)) may reduce circuit-induced complications during heart surgery in neonates.

  3. Adaptive structures - Test hardware and experimental results

    Science.gov (United States)

    Wada, Ben K.; Fanson, James L.; Chen, Gun-Shing; Kuo, Chin-Po

    1990-01-01

    The facilities and procedures used at JPL to test adaptive structures such as the large deployable reflector (LDR) are described and preliminary results are reported. The applications of adaptive structures in future NASA missions are outlined, and the techniques which are employed to modify damping, stiffness, and isolation characteristics, as well as geometric changes, are listed. The development of adaptive structures is shown to be effective as a result of new actuators and sensors, and examples are listed for categories such as fiber optics, shape-memory materials, piezoelectrics, and electrorheological fluids. Some ground test results are described for laboratory truss structures and truss test beds, which are shown to be efficient and easy to assemble in space. Adaptive structures are shown to be important for precision space structures such as the LDR, and can alleviate ground test requirements.

  4. Physicists purchase materials testing machine in support of pioneering particle physics experiments

    CERN Multimedia

    Sharpe, Suzanne

    2007-01-01

    "The particle physics group at Liverpool University has purchased an LRXPlus singlecolumn materials testing machine from Lloyd Instruments, which will be used to help characterise the carbon-fibre support frames for detectors used for state-of-the-art particle physics experiments." (1 page)

  5. Effectiveness and resolution of tests for evaluating the performance of cutting fluids in machining aerospace alloys

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Axinte, Dragos A.

    2008-01-01

    The paper discusses effectiveness and resolution of five cutting tests (turning, milling, drilling, tapping, VIPER grinding) and their quality output measures used in a multi-task procedure for evaluating the performance of cutting fluids when machining aerospace materials. The evaluation takes...

  6. Testing of machine wound second generation HTS tape Vacuum Pressure Impregnated coils

    Science.gov (United States)

    Swaffield, D.; Lewis, C.; Eugene, J.; Ingles, M.; Peach, D.

    2014-05-01

    Delamination of second generation (2G) High Temperature Superconducting (HTS) tapes has previously been reported when using resin based insulation systems for wound coils. One proposed root cause is the differential thermal contraction between the coil former and the resin encapsulated coil turns resulting in the tape c-axis tensile stress being exceeded. Importantly, delamination results in unacceptable degradation of the superconductor critical current level. To mitigate the delamination risk and prove winding, jointing and Vacuum Pressure Impregnation (VPI) processes in the production of coils for superconducting rotating machines at GE Power Conversion two scaled trial coils have been wound and extensively tested. The coils are wound from 12mm wide 2G HTS tape supplied by AMSC onto stainless steel 'racetrack' coil formers. The coils are wound in two layers which include both in-line and layer-layer joints subject to in-process test. The resin insulation system chosen is VPI and oven cured. Tests included; insulation resistance, repeat quench and recovery of the superconductor, heat runs and measurement of n-value, before and after multiple thermal cycling between ambient and 35 Kelvin. No degradation of coil performance is evidenced.

  7. Cryogenic Test Results of Hextek Mirror

    Science.gov (United States)

    Hadaway, James; Stahl, H. Philip; Eng, Ron; Hogue, William

    2004-01-01

    A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

  8. Armature reaction effects on a high temperature superconducting field winding of an synchronous machine: experimental results

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech

    2014-01-01

    This paper presents experimental results from the Superwind laboratory setup. Particular focus in the paper has been placed on describing and quantifying the influence of armature reaction on performance of the HTS filed winding. Presented experimental results have confirmed the HTS field winding...... sensitivity to both armature reaction intensity and angular position with respect to the HTS coils. Furthermore, the characterization of the HTS field winding has been correlated to the electromagnetic torque of the machine where the maximal Ic reduction of 21% has been observed for the maximum torque....

  9. Armature reaction effects on a high temperature superconducting field winding of an synchronous machine: experimental results

    Science.gov (United States)

    Mijatovic, Nenad; Jensen, Bogi Bech

    2014-05-01

    This paper presents experimental results from the Superwind laboratory setup. Particular focus in the paper has been placed on describing and quantifying the influence of armature reaction on performance of the HTS filed winding. Presented experimental results have confirmed the HTS field winding sensitivity to both armature reaction intensity and angular position with respect to the HTS coils. Furthermore, the characterization of the HTS field winding has been correlated to the electromagnetic torque of the machine where the maximal Ic reduction of 21% has been observed for the maximum torque.

  10. "Comparison of some Structural Analyses Methods used for the Test Pavement in the Danish Road Testing Machine

    DEFF Research Database (Denmark)

    Baltzer, S.; Zhang, W.; Macdonald, R.;

    1998-01-01

    A flexible test pavement, instrumented to measure stresses and strains in the three primary axes with the upper 400 mm of the subgrade, has been constructed and load tested in the Danish Road Testing Machine (RTM). One objective of this research, which is part of the International Pavement Subgrade...... methods used for the RTM test pavement with data from FWD testing undertaken after the construction and loading programmes. Multilayer linear elastic forward and backcalculation methods, a finite element program and MS Excel spreadsheet based methods are compared....

  11. Neuropsychological Test Selection for Cognitive Impairment Classification: A Machine Learning Approach

    Science.gov (United States)

    Williams, Jennifer A.; Schmitter-Edgecombe, Maureen; Cook, Diane J.

    2016-01-01

    Introduction Reducing the amount of testing required to accurately detect cognitive impairment is clinically relevant. The aim of this research was to determine the fewest number of clinical measures required to accurately classify participants as healthy older adult, mild cognitive impairment (MCI) or dementia using a suite of classification techniques. Methods Two variable selection machine learning models (i.e., naive Bayes, decision tree), a logistic regression, and two participant datasets (i.e., clinical diagnosis, clinical dementia rating; CDR) were explored. Participants classified using clinical diagnosis criteria included 52 individuals with dementia, 97 with MCI, and 161 cognitively healthy older adults. Participants classified using CDR included 154 individuals CDR = 0, 93 individuals with CDR = 0.5, and 25 individuals with CDR = 1.0+. Twenty-seven demographic, psychological, and neuropsychological variables were available for variable selection. Results No significant difference was observed between naive Bayes, decision tree, and logistic regression models for classification of both clinical diagnosis and CDR datasets. Participant classification (70.0 – 99.1%), geometric mean (60.9 – 98.1%), sensitivity (44.2 – 100%), and specificity (52.7 – 100%) were generally satisfactory. Unsurprisingly, the MCI/CDR = 0.5 participant group was the most challenging to classify. Through variable selection only 2 – 9 variables were required for classification and varied between datasets in a clinically meaningful way. Conclusions The current study results reveal that machine learning techniques can accurately classifying cognitive impairment and reduce the number of measures required for diagnosis. PMID:26332171

  12. Liquid flooded compression and expansion in scroll machines – Part II: Experimental testing and model validation

    OpenAIRE

    Bell, Ian; Lemort, Vincent; Groll, E. A.; James E. Braun; King, Galen; Horton, W. Travis

    2012-01-01

    The use of liquid-flooding in the compression and expansion of non-condensable gas in scroll compressors and expanders enables the possibility of quasi-isothermal working processes. Liquid-flooded scroll machines were installed in a fully-instrumented Liquid-Flooded Ericsson Cycle test rig to conduct entire cycle performance tests. In addition, detailed compressor and expander performance data was obtained. Oil mass fractions of up to 92% and 76% were added to the gas entering the scroll comp...

  13. Results of shielding characteristics tests in Monju

    Energy Technology Data Exchange (ETDEWEB)

    Usami, Shin; Suzuoki, Zenro; Deshimaru, Takehide; Nakashima, Fumiaki [Japan Nuclear Cycle Development Inst., Tsuruga, Fukui (Japan)

    2001-06-01

    In the prototype fast breeder reactor Monju, the shielding characteristics tests were made around the reactor core, the primary heat transport system, and the fuel handling and storage system as a part of the system start-up tests from 0% to 45% of rated power from October 1993 through December 1995. The results of the measurements, analyses and evaluations in these tests validated the FBR shielding analysis methods and demonstrated that there was a safe shielding design margin in Monju. The important basic data for use in future FBR shielding design were successfully acquired. In order to obtain more substantial basic data and to improve the accuracy of the analyses, the next shielding measurements are planned for the period of the system start-up tests at the restart of Monju. (author)

  14. Redox accountability test program: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, R.A.; Bray, L.A.

    1958-11-25

    This report details initial results of a large scale accountability test program which was recently carried out in the Redox Facility. The test, as originally planned which was to consist of the complete processing (no inventory-clean plant basis) of about 55 tons of selected metal in conjunction with an extensive analytical, sampling, and volume measurement program. With the exception of two incidents, the processing requirements (minimum inventory and measurement of all material) necessary to the success of the test, were met. The two incidents which increase the uncertainties associated with some of the material balance values obtained were: the discharge of an estimated 700 pounds of uranium to the floor in a transfer from F-5 to F-4 due tot he improper installation of the F-5 to F-4 transfer line (jumper) and the discovery of a large accumulation of plutonium ({approximately} 15 kg) in the L-2 stripping tower after completion of the test run.

  15. The Results of the Second NACEF Test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Hwan; Bae, Yoon-Yeong; Kim, Chan-Soo; Hong, Sung-Deok; Kim, Eung-Seon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    RCCS (Reactor Cavity Cooling System) is the only ex-vessel passive safety system that will ensure the safety of the PMR200, and its performance needs to be verified. For the difficulty of the fullscale test, a 1/4-scale RCCS facility, NACEF, was constructed at KAERI and a few tests have satisfactorily been performed. Here described are the results of the second main test which aimed at the evaluation of heat transfer with the scaled air velocity in the risers and the scaled air temperature increment during passing through the risers. The second main test was performed in the NACEF facility, the 1/4-scale RCCS mockup of PMR200. Natural convection cooling by buoyant force formed in the risers for a scaled condition. The RCCS in the prototypic PMR200 is expected to perform well. The heat transfer regime is in between the mixed convection and the forced convection.

  16. J series thruster thermal test results

    Science.gov (United States)

    Bechtel, R. T.; Dulgeroff, C. R.

    1982-01-01

    Test experience with J series ion thrusters have indicated that the present thruster design may result in excessive temperatures in areas which utilize organic materials such as wire insulation, with the resultant outgassing and potential contamination of insulating materials. Further, it appears that thermal data obtained with earlier thruster designs, such as the 700 series thruster, may not be directly applicable to the J series design. Two J series thrusters were fitted with thermocouples and critical temperatures measured for a variety of configurations and operating parameters. Completely enclosing the thruster to reduce facility contamination significantly increased temperatures prompting the selection of a compromise geometry for life testing. The operating parameter having the largest effect on temperatures was discharge power, while beam power affected little else than extraction system temperatures. Several off-normal operating modes were also investigated. Data believed to be sufficient to effectively modify existing thermal models were obtained from the tests.

  17. Light and short arc rubs in rotating machines: Experimental tests and modelling

    Science.gov (United States)

    Pennacchi, P.; Bachschmid, N.; Tanzi, E.

    2009-10-01

    Rotor-to-stator rub is a non-linear phenomenon which has been analyzed many times in rotordynamics literature, but very often these studies are devoted simply to highlight non-linearities, using very simple rotors, rather than to present reliable models. However, rotor-to-stator rub is actually one of the most common faults during the operation of rotating machinery. The frequency of its occurrence is increasing due to the trend of reducing the radial clearance between the seal and the rotor in modern turbine units, pumps and compressors in order to increase efficiency. Often the rub occurs between rotor and seals and the analysis of the phenomenon cannot set aside the consideration of the different relative stiffness. This paper presents some experimental results obtained by means of a test rig in which rub conditions of real machines are reproduced. In particular short arc rubs are considered and the shaft is stiffer than the obstacle. Then a model, suitable to be employed for real rotating machinery, is presented and the simulations obtained are compared with the experimental results. The model is able to reproduce the behaviour of the test rig.

  18. Results from new multi-megabar shockless compression experiments at the Z machine

    Science.gov (United States)

    Davis, Jean-Paul; Knudson, Marcus D.; Brown, Justin L.

    2017-01-01

    Sandia's Z Machine has been used to magnetically drive shockless compression of materials in a planar configuration to multi-megabar pressure levels, allowing accurate measurements of quasi-isentropic mechanical response at relatively low temperatures in the solid phase. This paper details recent improvements to design and analysis of such experiments, including the use of new data on the mechanical and optical response of lithium fluoride windows. Comparison of windowed and free-surface data on copper to 350 GPa lends confidence to the window correction method. Preliminary results are presented on gold to 500 GPa and platinum to 450 GPa; both appear stiffer than existing models.

  19. Cone Penetrometer N Factor Determination Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2014-03-05

    This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to releate resistance measurements taken with the cone penetrometer to shear strength.

  20. Conventional Anchor Test Results at Guam.

    Science.gov (United States)

    1980-10-01

    TITLE (- s..suft.j S. TYPE OF REPORT 6 PERIOD COVERED GI NVENTIONAL INCHOR TEST RESULTS Not final; Jan 1980 - Jun 1980 AT- 6.GU- PERFORMING ORO. REPORT...Z.P. Bazant Evanston IL OREGON STATE UNIVERSITY (CE Dept Grace) Corvallis, OR: CORVALLIS, OR (CE DEPT. BELL): Corvalis OR (School of Oceanography

  1. Development a Vision Based Seam Tracking System for None Destructive Testing Machines

    Directory of Open Access Journals (Sweden)

    Nasser moradi

    2013-04-01

    Full Text Available The automatic weld seam tracking is an important challenge in None Destructive Testing (NDT systems for welded pipe inspection. In this Study, a machine vision based seam tracker, is developed and implemented, instead of old electro-mechanical system. A novel algorithm based on the weld image centered is presented, to reduce Environment conditions and improve the seam tracking accuracy. The weld seam images are taken by a camera arranged ahead of the machine and the centered is extracted as a parameter to detect the weld position, and offset between this point and central axis is computed and used as control parameter of servomotors. Adaptive multi step segmentation t technique is employed to increase the probable of real edge of the welds and improve the line fitting accuracy. This new approach offers some important technical advantages over the existing solutions to weld seam detection: Its based on natural light and does not need any auxiliary light. The adaptive threshold segmentation technique applied, decrease Environmental lighting condition. Its accurate and stable in real time NDT testing machines. After a series of experiments in real industrial environment, it is demonstrated that accuracy of this method can improve the quality of NDT machines. The average tracking error is 1.5 pixels approximately 0.25mm..

  2. Qualification test results for the TIRS cryocooler

    Science.gov (United States)

    Marquardt, Eric; Gully, Wilfred; Marquardt, Jennifer; Boyle, Robert; Hale, Taylor

    2012-06-01

    Ball Aerospace has completed qualification testing of its flight Stirling-cycle mechanical cryocooler for the Thermal Infrared Sensor (TIRS), an instrument slated to fly on the Landsat Data Continuity Mission (LDCM) platform. The TIRS cooler, developed under subcontract to NASA Goddard Space Flight Center, consists of a sophisticated and highly reliable, two-stage, fixed regenerator Stirling cryocooler and its drive electronics. The TIRS cooler provides 2 W of 38 K cooling to the TIRS detectors and 9.8 W shield cooling to 85 K for less than 225 W total input power. Performance test results are reported.

  3. Design, Construction and Testing Of a Multipurpose Brick/Block Moulding Machine

    Directory of Open Access Journals (Sweden)

    S.O. Yakubu

    2015-02-01

    Full Text Available The provision of shelter is one the most basic demand of a Man all over the World. It is one the most important challenges a man faces in his life. The problem of good shelter varies from place to place. A good shelter provides, first and foremost Security and Privacy. In the developed world the problem is less pronounced, but in the developing nation like Nigeria, the problem of shelter is more pronounced. There is about eighteen (18 million housing units’ deficit in Nigeria. One of the most important materials used for building of a shelter is block/brick, but majority of the people cannot afford these materials (blocks or bricks due high cost. Therefore, the production of high quality and affordable blocks/bricks is paramount to solving housing problems in developing countries especially in Nigeria. Thus, this research focused on design construction and testing of a multipurpose machine that produces high quality blocks/bricks for low cost housing. That is, for low income communities/earners. The constructed motorized compressive earth brick (CEB/block making machine can produce on average a total of 2,215 bricks per day and 950 blocks per day. The cost of production of the machine was two hundred and eighty six thousand, eight hundred ninety (N286, 890.00 naira only. Whereas, the most common high-tech motorized CEB machine in Nigeria (Hydraform® with an average capacity of about 3,000 bricks per day costs about six million naira (N6,000,000.00K only. Thus, the machine is very affordable for small scale enterprise (SME. In other words, bricks or blocks produced by using this machine are relatively cheap and affordable for those in the rural areas and for low income earners.

  4. Kernel machine testing for risk prediction with stratified case cohort studies.

    Science.gov (United States)

    Payne, Rebecca; Neykov, Matey; Jensen, Majken Karoline; Cai, Tianxi

    2016-06-01

    Large assembled cohorts with banked biospecimens offer valuable opportunities to identify novel markers for risk prediction. When the outcome of interest is rare, an effective strategy to conserve limited biological resources while maintaining reasonable statistical power is the case cohort (CCH) sampling design, in which expensive markers are measured on a subset of cases and controls. However, the CCH design introduces significant analytical complexity due to outcome-dependent, finite-population sampling. Current methods for analyzing CCH studies focus primarily on the estimation of simple survival models with linear effects; testing and estimation procedures that can efficiently capture complex non-linear marker effects for CCH data remain elusive. In this article, we propose inverse probability weighted (IPW) variance component type tests for identifying important marker sets through a Cox proportional hazards kernel machine (CoxKM) regression framework previously considered for full cohort studies (Cai et al., 2011). The optimal choice of kernel, while vitally important to attain high power, is typically unknown for a given dataset. Thus, we also develop robust testing procedures that adaptively combine information from multiple kernels. The proposed IPW test statistics have complex null distributions that cannot easily be approximated explicitly. Furthermore, due to the correlation induced by CCH sampling, standard resampling methods such as the bootstrap fail to approximate the distribution correctly. We, therefore, propose a novel perturbation resampling scheme that can effectively recover the induced correlation structure. Results from extensive simulation studies suggest that the proposed IPW CoxKM testing procedures work well in finite samples. The proposed methods are further illustrated by application to a Danish CCH study of Apolipoprotein C-III markers on the risk of coronary heart disease. © 2015, The International Biometric Society.

  5. Neuropsychological Testing and Machine Learning Distinguish Alzheimer’s Disease from Other Causes for Cognitive Impairment

    Directory of Open Access Journals (Sweden)

    Helmut Hildebrandt

    2017-04-01

    Full Text Available With promising results in recent treatment trials for Alzheimer’s disease (AD, it becomes increasingly important to distinguish AD at early stages from other causes for cognitive impairment. However, existing diagnostic methods are either invasive (lumbar punctures, PET or inaccurate Magnetic Resonance Imaging (MRI. This study investigates the potential of neuropsychological testing (NPT to specifically identify those patients with possible AD among a sample of 158 patients with Mild Cognitive Impairment (MCI or dementia for various causes. Patients were divided into an early stage and a late stage group according to their Mini Mental State Examination (MMSE score and labeled as AD or non-AD patients based on a post-mortem validated threshold of the ratio between total tau and beta amyloid in the cerebrospinal fluid (CSF; Total tau/Aβ(1–42 ratio, TB ratio. All patients completed the established Consortium to Establish a Registry for Alzheimer’s Disease—Neuropsychological Assessment Battery (CERAD-NAB test battery and two additional newly-developed neuropsychological tests (recollection and verbal comprehension that aimed at carving out specific Alzheimer-typical deficits. Based on these test results, an underlying AD (pathologically increased TB ratio was predicted with a machine learning algorithm. To this end, the algorithm was trained in each case on all patients except the one to predict (leave-one-out validation. In the total group, 82% of the patients could be correctly identified as AD or non-AD. In the early group with small general cognitive impairment, classification accuracy was increased to 89%. NPT thus seems to be capable of discriminating between AD patients and patients with cognitive impairment due to other neurodegenerative or vascular causes with a high accuracy, and may be used for screening in clinical routine and drug studies, especially in the early course of this disease.

  6. Neuropsychological Testing and Machine Learning Distinguish Alzheimer's Disease from Other Causes for Cognitive Impairment.

    Science.gov (United States)

    Gurevich, Pavel; Stuke, Hannes; Kastrup, Andreas; Stuke, Heiner; Hildebrandt, Helmut

    2017-01-01

    With promising results in recent treatment trials for Alzheimer's disease (AD), it becomes increasingly important to distinguish AD at early stages from other causes for cognitive impairment. However, existing diagnostic methods are either invasive (lumbar punctures, PET) or inaccurate Magnetic Resonance Imaging (MRI). This study investigates the potential of neuropsychological testing (NPT) to specifically identify those patients with possible AD among a sample of 158 patients with Mild Cognitive Impairment (MCI) or dementia for various causes. Patients were divided into an early stage and a late stage group according to their Mini Mental State Examination (MMSE) score and labeled as AD or non-AD patients based on a post-mortem validated threshold of the ratio between total tau and beta amyloid in the cerebrospinal fluid (CSF; Total tau/Aβ(1-42) ratio, TB ratio). All patients completed the established Consortium to Establish a Registry for Alzheimer's Disease-Neuropsychological Assessment Battery (CERAD-NAB) test battery and two additional newly-developed neuropsychological tests (recollection and verbal comprehension) that aimed at carving out specific Alzheimer-typical deficits. Based on these test results, an underlying AD (pathologically increased TB ratio) was predicted with a machine learning algorithm. To this end, the algorithm was trained in each case on all patients except the one to predict (leave-one-out validation). In the total group, 82% of the patients could be correctly identified as AD or non-AD. In the early group with small general cognitive impairment, classification accuracy was increased to 89%. NPT thus seems to be capable of discriminating between AD patients and patients with cognitive impairment due to other neurodegenerative or vascular causes with a high accuracy, and may be used for screening in clinical routine and drug studies, especially in the early course of this disease.

  7. Design, Development and Testing of an Areca nut Dehusking Agri-machine

    Directory of Open Access Journals (Sweden)

    Kiran K

    2014-07-01

    Full Text Available Areca nut has to be processed in dry condition by peeling the outer shell completely. Peeling of Areca nut is very difficult by hand. However it is being done manually by using a sharp knife with a production rate of 3kg/hr. So it is essential to develop an agri-machine which will increase the production rate and safety to labourers. Presently there are few machines available but these machines are not suitable for variety of sizes of Areca nut which leads into the insufficient removal of outer shell of Areca nut. Therefore there is enough scope to develop a agri-machine suitable for variety of sizes of Areca nut which will overcome these problems. The present reserch work emphasizes on developing an Areca nut Dehusking agri-machine for three different sizes of Areca nut. The concept is to shear-off the husk of the dry Areca nut by shearing force. The features a Dehusking mechanism, and a power drive. The experiments were conducted by changing the blades, and selecting the best method. The first experiment were conducted by mounting set of two cutters separated by spacers for each size of Areca nut, then the set of two cutters were replaced by single cutters and the results of both the experiments were compared and concluded that the single cutters were more efficient than the set of two cutters in Dehusking the Areca nut.

  8. [Testing a computer-assisted bending machine for manufacturing orthodontic treatment elements].

    Science.gov (United States)

    Verma, D; Bourauel, C; May, O; Jäger, A

    2000-10-01

    The use of suitable orthodontic devices producing desired defined force systems is of importance for successful orthodontic treatment. Bending loops can be difficult and time-consuming. Computerised fabrication would enable very precise reproduction of individual loops. A bending machine has now been developed within the framework of a computer-assisted treatment concept. In this study, a prototype machine was used to fabricate U-, T- and delta loops made of stainless steel, cobalt chromium and titanium molybdenum wire. The various geometric parameters of each loop were measured to determine how precisely they had been produced. Furthermore, the force system of each loop were experimentally investigated during simulated activation in an orthodontic measurement and simulation system. The results indicate that the geometric parameters had an average error of 2.8 degrees for angles and 0.9 mm for lengths. Owing to the fabrication errors, loops of the same type produced different force systems. Overall, the new bending machine can fabricate different types of loop, but the requirements of very precise fabrication are currently not met. This fact, together with further limitations in terms of configuration, means that the machine cannot be used routinely at present. However, the machine can nevertheless be considered a good basis for further development.

  9. Methodologies for Combined Loads Tests Using a Multi-Actuator Test Machine

    Science.gov (United States)

    Rouse, Marshall

    2013-01-01

    The NASA Langley COmbined Loads Test System (COLTS) Facility was designed to accommodate a range of fuselage structures and wing sections and subject them to both quasistatic and cyclic loading conditions. Structural tests have been conducted in COLTS that address structural integrity issues of metallic and fiber reinforced composite aerospace structures in support of NASA Programs (i.e. the Aircraft Structural Integrity (ASIP) Program, High-Speed-Research program and the Supersonic Project, NASA Engineering and Safety Center (NESC) Composite Crew Module Project, and the Environmentally Responsible Aviation Program),. This paper presents experimental results for curved panels subjected to mechanical and internal pressure loads using a D-box test fixture. Also, results are presented that describe use of a checkout beam for development of testing procedures for a combined mechanical and pressure loading test of a Multi-bay box. The Multi-bay box test will be used to experimentally verify the structural performance of the Multi-bay box in support of the Environmentally Responsible Aviation Project at NASA Langley.

  10. Laboratory results of the AOF system testing

    Science.gov (United States)

    Kolb, Johann; Madec, Pierre-Yves; Arsenault, Robin; Oberti, Sylvain; Paufique, Jérôme; La Penna, Paolo; Ströbele, Stefan; Donaldson, Robert; Soenke, Christian; Suárez Valles, Marcos; Kiekebusch, Mario; Argomedo, Javier; Le Louarn, Miska; Vernet, Elise; Haguenauer, Pierre; Duhoux, Philippe; Aller-Carpentier, Emmanuel; Valenzuela, Jose Javier; Guerra, Juan Carlos

    2016-07-01

    For two years starting in February 2014, the AO modules GRAAL for HAWK-I and GALACSI for MUSE of the Adaptive Optics Facility project have undergone System Testing at ESO's Headquarters. They offer four different modes: NGS SCAO, LGS GLAO in the IR, LGS GLAO and LTAO in the visible. A detailed characterization of those modes was made possible by the existence of ASSIST, a test bench emulating an adaptive VLT including the Deformable Secondary Mirror, a star simulator and turbulence generator and a VLT focal plane re-imager. This phase aimed at validating all the possible components and loops of the AO modules before installation at the actual VLT that comprises the added complexity of real LGSs, a harsher non-reproducible environment and the adaptive telescope control. In this paper we present some of the major results obtained and challenges encountered during the phase of System Tests, like the preparation of the Acquisition sequence, the testing of the Jitter loop, the performance optimization in GLAO and the offload of low-order modes from the DSM to the telescope (restricted to the M2 hexapod). The System Tests concluded with the successful acceptance, shipping, installation and first commissioning of GRAAL in 2015 as well as the acceptance and shipping of GALACSI, ready for installation and commissioning early 2017.

  11. Field Cone Penetration Tests with Various Penetration Rates - Test Results

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    The test site is located at Nordre Ringgade near the town called Dronninglund in the northern Jutland in Denmark. The site area is relatively flat, and was chosen because it has a size of approximately 3 ha and contains a relatively thick deposit of silty soils. Furthermore the groundwater...... was encountered at approximately 0.2-0.6 m below the ground level. The soil stratigraphy of the test site was before test start identified by geotechnical borings results. The geotechnical borings indicated that the site contains of sandy silt with clay stripes from approx. 4.0 to 10 m. In the top the silty soil...... is very sandy with few clay stripes, and gradually the clay stripes increases wherefore the soil from approx. 10 m contains of clay with sandy silt stripes. Large soil sample was also collected from the test site in order to determine basic soil properties in the laboratory....

  12. Statistical analysis of concrete quality testing results

    Directory of Open Access Journals (Sweden)

    Jevtić Dragica

    2014-01-01

    Full Text Available This paper statistically investigates the testing results of compressive strength and density of control concrete specimens tested in the Laboratory for materials, Faculty of Civil Engineering, University of Belgrade, during 2012. The total number of 4420 concrete specimens were tested, which were sampled on different locations - either on concrete production site (concrete plant, or concrete placement location (construction site. To be exact, these samples were made of concrete which was produced on 15 concrete plants, i.e. placed in at 50 different reinforced concrete structures, built during 2012 by 22 different contractors. It is a known fact that the achieved values of concrete compressive strength are very important, both for quality and durability assessment of concrete inside the structural elements, as well as for calculation of their load-bearing capacity limit. Together with the compressive strength testing results, the data concerning requested (designed concrete class, matching between the designed and the achieved concrete quality, concrete density values and frequency of execution of concrete works during 2012 were analyzed.

  13. Prioritizing individual genetic variants after kernel machine testing using variable selection.

    Science.gov (United States)

    He, Qianchuan; Cai, Tianxi; Liu, Yang; Zhao, Ni; Harmon, Quaker E; Almli, Lynn M; Binder, Elisabeth B; Engel, Stephanie M; Ressler, Kerry J; Conneely, Karen N; Lin, Xihong; Wu, Michael C

    2016-12-01

    Kernel machine learning methods, such as the SNP-set kernel association test (SKAT), have been widely used to test associations between traits and genetic polymorphisms. In contrast to traditional single-SNP analysis methods, these methods are designed to examine the joint effect of a set of related SNPs (such as a group of SNPs within a gene or a pathway) and are able to identify sets of SNPs that are associated with the trait of interest. However, as with many multi-SNP testing approaches, kernel machine testing can draw conclusion only at the SNP-set level, and does not directly inform on which one(s) of the identified SNP set is actually driving the associations. A recently proposed procedure, KerNel Iterative Feature Extraction (KNIFE), provides a general framework for incorporating variable selection into kernel machine methods. In this article, we focus on quantitative traits and relatively common SNPs, and adapt the KNIFE procedure to genetic association studies and propose an approach to identify driver SNPs after the application of SKAT to gene set analysis. Our approach accommodates several kernels that are widely used in SNP analysis, such as the linear kernel and the Identity by State (IBS) kernel. The proposed approach provides practically useful utilities to prioritize SNPs, and fills the gap between SNP set analysis and biological functional studies. Both simulation studies and real data application are used to demonstrate the proposed approach.

  14. Machine learning for radioxenon event classification for the Comprehensive Nuclear-Test-Ban Treaty

    Energy Technology Data Exchange (ETDEWEB)

    Stocki, Trevor J., E-mail: trevor_stocki@hc-sc.gc.c [Radiation Protection Bureau, 775 Brookfield Road, A.L. 6302D1, Ottawa, ON, K1A 1C1 (Canada); Li, Guichong; Japkowicz, Nathalie [School of Information Technology and Engineering, University of Ottawa, 800 King Edward Avenue, Ottawa, ON, K1N 6N5 (Canada); Ungar, R. Kurt [Radiation Protection Bureau, 775 Brookfield Road, A.L. 6302D1, Ottawa, ON, K1A 1C1 (Canada)

    2010-01-15

    A method of weapon detection for the Comprehensive nuclear-Test-Ban-Treaty (CTBT) consists of monitoring the amount of radioxenon in the atmosphere by measuring and sampling the activity concentration of {sup 131m}Xe, {sup 133}Xe, {sup 133m}Xe, and {sup 135}Xe by radionuclide monitoring. Several explosion samples were simulated based on real data since the measured data of this type is quite rare. These data sets consisted of different circumstances of a nuclear explosion, and are used as training data sets to establish an effective classification model employing state-of-the-art technologies in machine learning. A study was conducted involving classic induction algorithms in machine learning including Naive Bayes, Neural Networks, Decision Trees, k-Nearest Neighbors, and Support Vector Machines, that revealed that they can successfully be used in this practical application. In particular, our studies show that many induction algorithms in machine learning outperform a simple linear discriminator when a signal is found in a high radioxenon background environment.

  15. Fabrication and Tests of M240 Machine Gun Barrels Lined with Stellite 25

    Science.gov (United States)

    2016-04-01

    nozzle design is the subject of a patent disclosure . Another source of the poor material properties of the cold-sprayed Biodur tubes was the fact...Fabrication and Tests of M240 Machine Gun Barrels Lined with Stellite 25 by William S de Rosset and Sean Fudger Weapons and Materials Research...SUPPLEMENTARY NOTES 14. ABSTRACT Two M240B barrel blanks were processed with the Gun Liner Emplacement with an Elastomeric Material procedure

  16. A support vector machine based test for incongruence between sets of trees in tree space

    Science.gov (United States)

    2012-01-01

    Background The increased use of multi-locus data sets for phylogenetic reconstruction has increased the need to determine whether a set of gene trees significantly deviate from the phylogenetic patterns of other genes. Such unusual gene trees may have been influenced by other evolutionary processes such as selection, gene duplication, or horizontal gene transfer. Results Motivated by this problem we propose a nonparametric goodness-of-fit test for two empirical distributions of gene trees, and we developed the software GeneOut to estimate a p-value for the test. Our approach maps trees into a multi-dimensional vector space and then applies support vector machines (SVMs) to measure the separation between two sets of pre-defined trees. We use a permutation test to assess the significance of the SVM separation. To demonstrate the performance of GeneOut, we applied it to the comparison of gene trees simulated within different species trees across a range of species tree depths. Applied directly to sets of simulated gene trees with large sample sizes, GeneOut was able to detect very small differences between two set of gene trees generated under different species trees. Our statistical test can also include tree reconstruction into its test framework through a variety of phylogenetic optimality criteria. When applied to DNA sequence data simulated from different sets of gene trees, results in the form of receiver operating characteristic (ROC) curves indicated that GeneOut performed well in the detection of differences between sets of trees with different distributions in a multi-dimensional space. Furthermore, it controlled false positive and false negative rates very well, indicating a high degree of accuracy. Conclusions The non-parametric nature of our statistical test provides fast and efficient analyses, and makes it an applicable test for any scenario where evolutionary or other factors can lead to trees with different multi-dimensional distributions. The

  17. A novel method for machine performance degradation assessment based on fixed cycle features test

    Science.gov (United States)

    Liao, Linxia; Lee, Jay

    2009-10-01

    This paper presents a novel machine performance degradation scheme based on fixed cycle features test (FCFT). Instead of monitoring the machine under constant working load, FCFT introduces a new testing method which obtains data during the transient periods of different working loads. A novel performance assessment method based on those transient data without failure history is proposed. Wavelet packet analysis (WPA) is applied to extract features which capture the dynamic characteristics from the non-stationary vibration data. Principal component analysis (PCA) is used to reduce the dimension of the feature space. Gaussian mixture model (GMM) is utilized to approximate the density distribution of the lower-dimensional feature space which consists of the major principal components. The performance index of the machine is calculated based on the overlap between the distribution of the baseline feature space and that of the testing feature space. Bayesian information criterion (BIC) is used to determine the number of mixtures for the GMM and a density boosting method is applied to achieve better accuracy of the distribution estimation. A case study for a chiller system performance assessment is used as an example to validate the effectiveness of the proposed method.

  18. PHASE I SINGLE CELL ELECTROLYZER TEST RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Steimke, J; Timothy Steeper, T

    2008-08-05

    This document reports the results of Phase I Single Cell testing of an SO{sub 2}-Depolarized Water Electrolyzer. Testing was performed primarily during the first quarter of FY 2008 at the Savannah River National Laboratory (SRNL) using an electrolyzer cell designed and built at SRNL. Other facility hardware were also designed and built at SRNL. This test further advances this technology for which work began at SRNL in 2005. This research is valuable in achieving the ultimate goal of an economical hydrogen production process based on the Hybrid Sulfur (HyS) Cycle. The focus of this work was to conduct single cell electrolyzer tests to further develop the technology of SO{sub 2}-depolarized electrolysis as part of the HyS Cycle. The HyS Cycle is a hybrid thermochemical cycle that may be used in conjunction with advanced nuclear reactors or centralized solar receivers to produce hydrogen by water-splitting. Like all other sulfur-based cycles, HyS utilizes the high temperature thermal decomposition of sulfuric acid to produce oxygen and regenerate sulfur dioxide. The unique aspect of HyS is the generation of hydrogen in a water electrolyzer that is operated under conditions where dissolved sulfur dioxide depolarizes the anodic reaction, resulting in substantial voltage reduction. Low cell voltage is essential for both thermodynamic efficiency and hydrogen cost. Sulfur dioxide is oxidized at the anode, producing sulfuric acid that is sent to the high temperature acid decomposition portion of the cycle. The electrolyzer cell uses the membrane electrode assembly (MEA) concept. The anode and cathode are formed by spraying platinum containing catalyst on both sides of a Proton Exchange Membrane (PEM). In most testing the material of the PEM was NafionR. The electrolyzer cell active area can be as large as 54.8 cm{sup 2}. Feed to the anode of the electrolyzer is a sulfuric acid solution containing sulfur dioxide. The partial pressure of sulfur dioxide could be varied in the

  19. Advanced Thermal Simulator Testing: Thermal Analysis and Test Results

    Science.gov (United States)

    Bragg-Sitton, Shannon M.; Dickens, Ricky; Dixon, David; Reid, Robert; Adams, Mike; Davis, Joe

    2008-01-01

    Work at the NASA Marshall Space Flight Center seeks to develop high fidelity, electrically heated thermal simulators that represent fuel elements in a nuclear reactor design to support non-nuclear testing applicable to the development of a space nuclear power or propulsion system. Comparison between the fuel pins and thermal simulators is made at the outer fuel clad surface, which corresponds to the outer sheath surface in the thermal simulator. The thermal simulators that are currently being tested correspond to a SNAP derivative reactor design that could be applied for Lunar surface power. These simulators are designed to meet the geometric and power requirements of a proposed surface power reactor design, accommodate testing of various axial power profiles, and incorporate imbedded instrumentation. This paper reports the results of thermal simulator analysis and testing in a bare element configuration, which does not incorporate active heat removal, and testing in a water-cooled calorimeter designed to mimic the heat removal that would be experienced in a reactor core.

  20. Preliminary test results for the SVX4

    Energy Technology Data Exchange (ETDEWEB)

    Christofek, L.; Hanagaki, K.; Rapidis, P.; Utes, M.; /Fermilab

    2005-06-01

    We present and summarize the preliminary test results for SVX4 chip testing. There are presently two versions of the SVX4. Version 2 has on-chip bypassing and Version 1 does not. The on-chip bypassing is a layer of transistors under the front-end analog pipeline that acts as a bypassing capacitor for the voltage supply. Its size is about a microfarad. We aggressively choose to test Version 2 because of this feature. The feature is advantageous for hybrid design because it eliminates the need for an additional passive component on the hybrid itself by placing it on the actual SVX4 die. Also, the SVX4 was designed to operate in two modes: D. and CDF. One can set which mode the chip will operate by placing a jumper in the proper position on the SVX4 chip carrier. In either mode, the chip can either use the operating parameters from the shift register or the shadow register. Similarly, this is selected by placing a jumper on the SVX4 chip carrier. This chip has this feature because it was unknown whether the new design of the shadow register would be operable. The shadow register is also call the SEU register or Single Event Upset register. An introduction into the functionality of the chip and an explanation on the difference between D. and CDF mode can be found in the SVX4 User's Manual [1].

  1. Arc melter demonstration baseline test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process.

  2. Updated Results of Ultrasonic Transducer Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua; Palmer, Joe [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, 38415-3840 (United States); Ramuhalli, Pradeep; Keller, Paul; Montgomery, Robert [Pacific Northwest National Laboratory, 902 Battelle Blvd. Richland, WA, 99354 (United States); Chien, Hual-Te [Argonne National Laboratory, 9700 S. Cass Avenue Argonne, IL, 60439 (United States); Tittmann, Bernhard; Reinhardt, Brian [Pennsylvania State University, 212 Earth and Engr. Sciences Building, University Park, PA, 16802 (United States); Kohse, Gordon [Massachusetts Institute of Technology, 77 Massachusetts Ave. Cambridge, MA 02139 (United States); Rempe, Joy [Rempe and Associates, LLC, 360 Stillwater, Idaho Falls, ID 83404 (United States); Villard, J.F. [Commissariat a l' energie atomique et aux energies alternatives, Centre d' etudes de Cadarache, 13108 Saint-Paul-lez-Durance (France)

    2015-07-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10{sup 21} n/cm{sup 2}. A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET-ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation. (authors)

  3. Combination of Universal Mechanical Testing Machine with Atomic Force Microscope for Materials Research

    Science.gov (United States)

    Zhong, Jian; He, Dannong

    2015-08-01

    Surface deformation and fracture processes of materials under external force are important for understanding and developing materials. Here, a combined horizontal universal mechanical testing machine (HUMTM)-atomic force microscope (AFM) system is developed by modifying UMTM to combine with AFM and designing a height-adjustable stabilizing apparatus. Then the combined HUMTM-AFM system is evaluated. Finally, as initial demonstrations, it is applied to analyze the relationship among macroscopic mechanical properties, surface nanomorphological changes under external force, and fracture processes of two kinds of representative large scale thin film materials: polymer material with high strain rate (Parafilm) and metal material with low strain rate (aluminum foil). All the results demonstrate the combined HUMTM-AFM system overcomes several disadvantages of current AFM-combined tensile/compression devices including small load force, incapability for large scale specimens, disability for materials with high strain rate, and etc. Therefore, the combined HUMTM-AFM system is a promising tool for materials research in the future.

  4. Unit cell sparger test program and analysis of test results

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Kyung; Song, C. H.; Cho, S.; Yoon, Y. J

    2003-11-01

    This report presents the results of test data from CPT-3 test and the effect of important parameters on the IRWST load. The object of CPT-3 test is to determine the influence of air mass in the piping on the IRWST (In-containment Refueling Water Storage Tank) boundary during an operation of Safety Depressurization and Vent System (SDVS). The test was conducted from an initial system pressure of 15.2 MPa, a steam temperature of 343.3 .deg. C, and an air mass of 3.34 lb. Following valve actuation, the pressure within the discharge line underwent pressure transient due to high pressure steam from the pressurizer and the discharged high pressure air formed air bubbles, which expanded and compressed periodically in the simulated IRWST. Air bubble oscillation was terminated within 2 s into the test. The magnitude of the pressure wave during the air clearing period was inversely proportional to the distance and very abrupt pressure spikes were observed in case the distance from the sparger holes to the submerged structure was less than 0.9 m. After the isolation valves were closed, the water in the simulated IRWST was considered to rise up to the 2.4m from the water surface in the quench tank. The amount of air mass in the piping, water temperature in the simulated IRWST, air temperature in the piping had not significant effect on the pressure loading during an air clearing period. However, the opening time of the isolation valve, steam mass flow rate, and submergence of an sparger have been shown to have great effects on the pressure loading during an air clearing period. 2 % of sparger flow area seems to be sufficient for the vacuum breaker area to mitigate the water hammering caused by abrupt water level rising during valve closure.

  5. Results from the Cooler and Lead Tests

    Energy Technology Data Exchange (ETDEWEB)

    Green, Michael A

    2010-06-10

    The report presents the results of testing MICE spectrometer magnet current leads on a test apparatus that combines both the copper leads and the high temperature superconducting (HTS) leads with a single Cryomech PT415 cooler and liquid helium tank. The current is carried through the copper leads from 300 K to the top of the HTS leads. The current is then carried through the HTS leads to a feed-through from the vacuum space to the inside of a liquid helium tank. The experiment allows one to measure the performance of both cooler stages along with the performance of the leads. While the leads were powered we measured the voltage drops through the copper leads, through the HTS leads, through spliced to the feed-through, through the feed-through and through the low-temperature superconducting loop that connects one lead to the other. Measurements were made using the leads that were used in spectrometer magnet 1A and spectrometer magnet 2A. These are the same leads that were used for Superbend and Venus magnets at LBNL. The IL/A for these leads was 5.2 x 10{sup 6} m{sup -1}. The leads turned out to be too long. The same measurements were made using the leads that were installed in magnet 2B. The magnet 2B leads had an IL/A of 3.3 x 10{sup 6} A m{sup -1}. This report discusses the cooler performance and the measured electrical performance of the lead circuit that contains the copper leads and the superconducting leads. All of the HTS leads that were installed in magnet 2B were current tested using this apparatus.

  6. Subgroup effects despite homogeneous heterogeneity test results

    Directory of Open Access Journals (Sweden)

    Lubsen Jacobus

    2010-05-01

    Full Text Available Abstract Background Statistical tests of heterogeneity are very popular in meta-analyses, as heterogeneity might indicate subgroup effects. Lack of demonstrable statistical heterogeneity, however, might obscure clinical heterogeneity, meaning clinically relevant subgroup effects. Methods A qualitative, visual method to explore the potential for subgroup effects was provided by a modification of the forest plot, i.e., adding a vertical axis indicating the proportion of a subgroup variable in the individual trials. Such a plot was used to assess the potential for clinically relevant subgroup effects and was illustrated by a clinical example on the effects of antibiotics in children with acute otitis media. Results Statistical tests did not indicate heterogeneity in the meta-analysis on the effects of amoxicillin on acute otitis media (Q = 3.29, p = 0.51; I2 = 0%; T2 = 0. Nevertheless, in a modified forest plot, in which the individual trials were ordered by the proportion of children with bilateral otitis, a clear relation between bilaterality and treatment effects was observed (which was also found in an individual patient data meta-analysis of the included trials: p-value for interaction 0.021. Conclusions A modification of the forest plot, by including an additional (vertical axis indicating the proportion of a certain subgroup variable, is a qualitative, visual, and easy-to-interpret method to explore potential subgroup effects in studies included in meta-analyses.

  7. Flash lidar performance testing: configuration and results

    Science.gov (United States)

    Poberezhskiy, Ilya; Johnson, Andrew; Chang, Daniel; Ek, Eric; Natzic, David; Spiers, Gary; Penniman, Steve; Short, Brad

    2012-06-01

    Future planetary and lunar landers can benefit from a hazard detection (HD) system that employs a lidar to create a highresolution 3D terrain map in the vicinity of the landing site and an onboard computer to process the lidar data and identify the safest landing site within the surveyed area. A divert maneuver would then be executed to land in this safe site. An HD system enables landing in regions with a relatively high hazard abundance that would otherwise be considered unacceptably risky, but are of high interest to the scientific community. A key component of a HD system is a lidar with the ability to generate a 3D terrain image with the required range precision in the prescribed time and fits within the project resource constraints. In this paper, we present the results obtained during performance testing of a prototype "GoldenEye" 3D flash lidar developed by ASC, Inc. The testing was performed at JPL with the lidar and the targets separated by 200 m. The analysis of the lidar performance obtained for different target types and albedos, pulse energies, and fields of view is presented and compared to key HD lidar requirements identified for the Mars 2018 lander.

  8. Tuned Chamber Core Panel Acoustic Test Results

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.

    2016-01-01

    This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.

  9. Analysis of CEDM test result(1)

    Energy Technology Data Exchange (ETDEWEB)

    Jun, H. G.; Chung, C. H.; Yoon, Y. J.; Donh, C. H.; Park, J. K. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-05-01

    The performance tests of the control element drive mechanism (CEDM) of Korean Next Generation Reactor(KNGR) were carried out. The performance tests consist of endurance test, power test, air cooling test and drop test. The endurance test was carried out to get 500,650 steps (31,290.6 ft) of CEDM movement. In power test, the motor driving power was measured for the cases of withdrawl, inserting, and holding states of CEDM. In air cooling test, the power to move the CEA was calculated from the measurements of temperature rising of air and it was compared with the measurement of power test. The 678 times of the drop test were carried out. For all drop tests, the drop time was shorter than the acceptance criteria of 4 sec. The effects of loop temperature and flow rate were investigated in drop test. After endurance test, the CEDM assembly was disassembled and visually inspected, and it was found out that the motor are not injured, bur the drive shaft is damaged seriously. 3 refs., 34 figs., 17 tabs. (Author)

  10. Commissioning of ALFABURST: initial tests and results

    CERN Document Server

    Rajwade, Kaustubh; Lorimer, Duncan; Karastergiou, Aris; Werthimer, Dan; Siemion, Andrew; MacMahon, David; Cobb, Jeff; Williams, Christopher; Armour, Wes

    2016-01-01

    Fast Radio Bursts (FRBs) are apparently one-time, relatively bright radio pulses that have been observed in recent years. The origin of FRBs is currently unknown and many instruments are being built to detect more of these bursts to better characterize their physical properties and identify the source population. ALFABURST is one such instrument. ALFABURST takes advantage of the 7-beam Arecibo L-band Feed Array (ALFA) receiver on the 305-m Arecibo Radio Telescope in Puerto Rico, to detect FRBs in real-time at L-band (1.4 GHz). We present the results of recent on-sky tests and observations undertaken during the commissioning phase of the instrument. ALFABURST is now available for commensal observations with other ALFA projects.

  11. Results of the fourth Hanna field test

    Energy Technology Data Exchange (ETDEWEB)

    Covell, J. R.; Wojdac, L. F.; Barbour, F. A.; Gardner, G. W.; Glass, R.; Hommert, P. J.

    1980-01-01

    The second phase (Hanna IVB) of a coal gasification experiment near Hanna, Wyoming, was completed in September 1979. The experiment attempted to link and gasify coal between process wells spaced 34.3 meters apart. Intermediate wells were positioned between the process wells so that the link could be relayed over shorter distances. Reverse combustion linking was attempted over a 22.9-meter and a 11.4-meter distance of the total well spacing. Thermal activity was generally noted in the upper 3 meters of the coal seam during the link. Two attempts to gasify over the 34.3-meter distance resulted in the propagation of the burn front at the coal overburden interface. Post-burn evaluation indicates fractures as major influencing factors of the combustion process. The Hanna IVB field test provided much insight into influence that geologic features have on in situ coal combustion. The influence of these faults, permeable zones, and cleats, on the air flow patterns can drastically change the overall results of a gasification experiment and should be studied further. The overall results of Hanna IVB were discouraging because of the rapid decline in the heating values for the production gas and the amount of coal gasified. With more complete geologic characerization prior to experimentation and proper well completions, it is believed that most of the subsurface operational problems encountered during Hanna IV could have been avoided.

  12. Fs-laser micro machining for μ-TLM resistivity test structures in photovoltaic TCO multilayers

    Science.gov (United States)

    Krause, Stephan; Kaufmann, Kai; Lancaster, Kevin; Naumann, Volker; Großer, Stephan; Hagendorf, Christian

    2016-04-01

    In this work we developed a new approach for resistivity measurements based on fs laser micro machining of μ-TLM test structures. This method is applied to highly resistive interfacial and conductive bulk multilayer systems in photovoltaic TCO thin film devices. Resistivity data has been acquired by a new TLM based method at μm-dimensions (μ-TLM, patent pending, DE 102014211352.0). For this approach, isolating trenches are prepared in the µm range with reasonable effort using fs laser processing. The application of ultrashort pulses with a laser wavelength in the IR range (λ = 1.03 μm) allows selective removal of the top SnO2 layer of the TCO multilayer stack by a reduced thermal influence on the layers beneath and in the adjacent region of the laser trenches. Small effective optical penetration and ablation depth was achieved by an ultrafast thermal ablation mechanism via free carrier absorption at the interface of the SnO2/ITO layers. Therefore the risk of laser induced modification of the electric layer properties is negligible. The μ-TLM test structure results in highly accurate and reproducible resistivity data. Applied to SnO2/ITO/glass double layer stacks, the obtained resistivity values for the SnO2 interfacial layer (ρTO = 40.5 kΩμm) and for the indium tin oxide thin film (ρITO = 1.3 Ωμm) agree with reference data from four-point-probing and from literature.

  13. Engineering model development and test results

    Science.gov (United States)

    Wellman, John A.

    1993-08-01

    The correctability of the primary mirror spherical error in the Wide Field/Planetary Camera (WF/PC) is sensitive to the precise alignment of the incoming aberrated beam onto the corrective elements. Articulating fold mirrors that provide +/- 1 milliradian of tilt in 2 axes are required to allow for alignment corrections in orbit as part of the fix for the Hubble space telescope. An engineering study was made by Itek Optical Systems and the Jet Propulsion Laboratory (JPL) to investigate replacement of fixed fold mirrors within the existing WF/PC optical bench with articulating mirrors. The study contract developed the base line requirements, established the suitability of lead magnesium niobate (PMN) actuators and evaluated several tilt mechanism concepts. Two engineering model articulating mirrors were produced to demonstrate the function of the tilt mechanism to provide +/- 1 milliradian of tilt, packaging within the space constraints and manufacturing techniques including the machining of the invar tilt mechanism and lightweight glass mirrors. The success of the engineering models led to the follow on design and fabrication of 3 flight mirrors that have been incorporated into the WF/PC to be placed into the Hubble Space Telescope as part of the servicing mission scheduled for late 1993.

  14. Two or three machined vs roughened surface dental implants loaded immediately supporting total fixed prostheses: 1-year results from a randomised controlled trial.

    Science.gov (United States)

    Cannizzaro, Gioacchino; Gastaldi, Giorgio; Gherlone, Enrico; Vinci, Raffaele; Loi, Ignazio; Trullenque-Eriksson, Anna; Esposito, Marco

    2017-01-01

    To compare implants with machined vs roughened surfaces placed flapless in totally edentulous jaws and immediately restored with metal-resin screw-retained cross-arch prostheses. Mandibles were rehabilitated with two implants (Fixed-on-2 or Fo2) and maxillae with three implants (Fixed-on-3 or Fo3). Forty edentulous or to be rendered edentulous patients (20 in the mandible and 20 in the maxilla) were randomised to the machined group (20 patients: 10 mandibles and 10 maxillae) and to the roughened group (20 patients: 10 mandibles and 10 maxillae) according to a parallel group design. To be immediately loaded implants had to be inserted with a minimum torque of 60 Ncm. Outcome measures were prosthesis and implant failures, complications and peri-implant marginal bone level changes evaluated up to 1 year post-loading. Flaps were raised in four patients from the machined group. Four prostheses on machined implants and three on roughened implants were delayed for loading because a sufficient insertion torque was not obtained. There were no dropouts 1 year after loading. Two maxillary machined implants were lost in two patients (difference in proportions = 0.10; 95% CI = -0.03 to 0.23; P (Fisher's exact test) = 0.487); one maxillary Fo3 prosthesis on machined implants and one mandibular Fo2 prosthesis on roughened implants had to be remade (difference in proportions = 0; 95% CI = -0.14 to 0.14; P (Fisher's exact test) = 1.000). Five patients with machined implants had six complications vs seven patients who had eight complications at roughened implants (difference in proportions = -0.10; 95% CI = -0.38 to 0.18; P (Fisher's exact test) = 0.731). There were no statistically significant differences for implant failures, prosthetic failures or complications between groups. There were no statistically significant differences for marginal peri-implant bone levels between the two groups (estimate of the difference = -0.06 mm; 95% CI = -0.23 to 0.10; P (ANCOVA) = 0.445), with

  15. 检测纸质绝缘材料x射线机的改进%Test the Improvement of Paper Insulation Material X-ray Machine

    Institute of Scientific and Technical Information of China (English)

    卢国庆; 吴军霞

    2012-01-01

    Summarize the importance of using the X-ray machine to test the paper insulation material, operating principles about X-ray to test the paper insulation material, the existing problems of common medical X-ray machine testing the paper insulation material. Describe the improvement programs to the common medical X-ray machine, compare with the working results of im- proved X-ray machine, put forward the growing trend about the testing paper insulation material X-ray machine.%文章综述了用x射线机检测纸质绝缘材料的必要性、工作原理及普通医用x射线机检测纸质绝缘材料存在的问题。提出了对普通医用x射线机的改进方案,对改进后的x射线机工作效果进行了比较,提出了检测纸质绝缘材料x射线机的发展趋势。

  16. Study of pulmonary (lung) functioning of commercial wheat grinding machine operators in India using spirometric testing.

    Science.gov (United States)

    Agashe, Abhijeet; Deshpande, V S

    2010-04-01

    In ancient times, in India each household had a chakki to mill the wheat. There was no concept of getting wheat grounded from outside. With the fast changing lifestyle, this tradition has almost disappeared now. Today every city of India has numerous commercial wheat grinding machine shops located at various places. Other than states like Punjab, this occupation is mostly unorganized and little has been done to look into the welfare and health of these machine operators. Like most of the occupations, this occupation of wheat grinding also has several occupational hazards and injuries associated with it. The most obvious of them all in this case is due to the continuous exposure of the operators to the rising dust wheat particles, commonly called atta). This perpetual inhaling ofpollutants exposes the operators to risks of pulmonary malfunctioning. Therefore, this paper attempts to determine the pulmonary functioning of the commercial wheat grinding machine operators in India using spirometric testing. On the basis of the anthropometric data, effort has been done to develop the expected lung performance. Further, the actual lung performance of the operators is measured and compared with expected performance.

  17. Summary of CPAS EDU Testing Analysis Results

    Science.gov (United States)

    Romero, Leah M.; Bledsoe, Kristin J.; Davidson, John.; Engert, Meagan E.; Fraire, Usbaldo, Jr.; Galaviz, Fernando S.; Galvin, Patrick J.; Ray, Eric S.; Varela, Jose

    2015-01-01

    The Orion program's Capsule Parachute Assembly System (CPAS) project is currently conducting its third generation of testing, the Engineering Development Unit (EDU) series. This series utilizes two test articles, a dart-shaped Parachute Compartment Drop Test Vehicle (PCDTV) and capsule-shaped Parachute Test Vehicle (PTV), both of which include a full size, flight-like parachute system and require a pallet delivery system for aircraft extraction. To date, 15 tests have been completed, including six with PCDTVs and nine with PTVs. Two of the PTV tests included the Forward Bay Cover (FBC) provided by Lockheed Martin. Advancements in modeling techniques applicable to parachute fly-out, vehicle rate of descent, torque, and load train, also occurred during the EDU testing series. An upgrade from a composite to an independent parachute simulation allowed parachute modeling at a higher level of fidelity than during previous generations. The complexity of separating the test vehicles from their pallet delivery systems necessitated the use the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulator for modeling mated vehicle aircraft extraction and separation. This paper gives an overview of each EDU test and summarizes the development of CPAS analysis tools and techniques during EDU testing.

  18. MIRAGE read-in integrated circuit testing results

    Science.gov (United States)

    Hoelter, Theodore R.; Henry, Blake A.; Graff, John H.; Aziz, Naseem Y.

    1999-07-01

    This paper describes the test results for the MIRAGE read- in-integrated-circuit (RIIC) designed by Indigo Systems Corporation. This RIIC, when mated with suspended membrane, micro-machined resistive elements, forms a highly advanced emitter array. This emitter array is used by Indigo and Santa Barbara Infrared Incorporated in a jointly developed product for infrared scene generation, called MIRAGE. The MIRAGE RIIC is a 512 X 512 pixel design which incorporates a number of features that extend the state of the art for emitter array RIIC devices. These innovations include an all-digital interface for scene data, snapshot image updates (all pixels show the new frame simultaneously), frame rates up to 200 Hz, operating modes that control the device output, power consumption, and diagnostic configuration. Tests measuring operating speed, RIIC functionality and D/A converter performance were completed. At 2.1 X 2.3 cm, this die is also the largest nonstitched device ever made by Indigo's foundry, American Microsystems Incorporated. As with any IC design, die yield is a critical factor that typically scales with the size and complexity. Die yield, and a statistical breakdown of the failures observed will be discussed.

  19. Investigation of Dynamic Force/Vibration Transmission Characteristics of Four-Square Type Gear Durability Test Machines

    Science.gov (United States)

    Kahraman, Ahmet

    2002-01-01

    In this study, design requirements for a dynamically viable, four-square type gear test machine are investigated. Variations of four-square type gear test machines have been in use for durability and dynamics testing of both parallel- and cross-axis gear set. The basic layout of these machines is illustrated. The test rig is formed by two gear pairs, of the same reduction ratio, a test gear pair and a reaction gear pair, connected to each other through shafts of certain torsional flexibility to form an efficient, closed-loop system. A desired level of constant torque is input to the circuit through mechanical (a split coupling with a torque arm) or hydraulic (a hydraulic actuator) means. The system is then driven at any desired speed by a small DC motor. The main task in hand is the isolation of the test gear pair from the reaction gear pair under dynamic conditions. Any disturbances originated at the reaction gear mesh might potentially travel to the test gearbox, altering the dynamic loading conditions of the test gear mesh, and hence, influencing the outcome of the durability or dynamics test. Therefore, a proper design of connecting structures becomes a major priority. Also, equally important is the issue of how close the operating speed of the machine is to the resonant frequencies of the gear meshes. This study focuses on a detailed analysis of the current NASA Glenn Research Center gear pitting test machine for evaluation of its resonance and vibration isolation characteristics. A number of these machines as the one illustrated has been used over last 30 years to establish an extensive database regarding the influence of the gear materials, processes surface treatments and lubricants on gear durability. This study is intended to guide an optimum design of next generation test machines for the most desirable dynamic characteristics.

  20. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test...

  1. Results of error correction techniques applied on two high accuracy coordinate measuring machines

    Energy Technology Data Exchange (ETDEWEB)

    Pace, C.; Doiron, T.; Stieren, D.; Borchardt, B.; Veale, R. (Sandia National Labs., Albuquerque, NM (USA); National Inst. of Standards and Technology, Gaithersburg, MD (USA))

    1990-01-01

    The Primary Standards Laboratory at Sandia National Laboratories (SNL) and the Precision Engineering Division at the National Institute of Standards and Technology (NIST) are in the process of implementing software error correction on two nearly identical high-accuracy coordinate measuring machines (CMMs). Both machines are Moore Special Tool Company M-48 CMMs which are fitted with laser positioning transducers. Although both machines were manufactured to high tolerance levels, the overall volumetric accuracy was insufficient for calibrating standards to the levels both laboratories require. The error mapping procedure was developed at NIST in the mid 1970's on an earlier but similar model. The error mapping procedure was originally very complicated and did not make any assumptions about the rigidness of the machine as it moved, each of the possible error motions was measured at each point of the error map independently. A simpler mapping procedure was developed during the early 1980's which assumed rigid body motion of the machine. This method has been used to calibrate lower accuracy machines with a high degree of success and similar software correction schemes have been implemented by many CMM manufacturers. The rigid body model has not yet been used on highly repeatable CMMs such as the M48. In this report we present early mapping data for the two M48 CMMs. The SNL CMM was manufactured in 1985 and has been in service for approximately four years, whereas the NIST CMM was delivered in early 1989. 4 refs., 5 figs.

  2. Combining Multiple Hypothesis Testing with Machine Learning Increases the Statistical Power of Genome-wide Association Studies

    Science.gov (United States)

    Mieth, Bettina; Kloft, Marius; Rodríguez, Juan Antonio; Sonnenburg, Sören; Vobruba, Robin; Morcillo-Suárez, Carlos; Farré, Xavier; Marigorta, Urko M.; Fehr, Ernst; Dickhaus, Thorsten; Blanchard, Gilles; Schunk, Daniel; Navarro, Arcadi; Müller, Klaus-Robert

    2016-11-01

    The standard approach to the analysis of genome-wide association studies (GWAS) is based on testing each position in the genome individually for statistical significance of its association with the phenotype under investigation. To improve the analysis of GWAS, we propose a combination of machine learning and statistical testing that takes correlation structures within the set of SNPs under investigation in a mathematically well-controlled manner into account. The novel two-step algorithm, COMBI, first trains a support vector machine to determine a subset of candidate SNPs and then performs hypothesis tests for these SNPs together with an adequate threshold correction. Applying COMBI to data from a WTCCC study (2007) and measuring performance as replication by independent GWAS published within the 2008-2015 period, we show that our method outperforms ordinary raw p-value thresholding as well as other state-of-the-art methods. COMBI presents higher power and precision than the examined alternatives while yielding fewer false (i.e. non-replicated) and more true (i.e. replicated) discoveries when its results are validated on later GWAS studies. More than 80% of the discoveries made by COMBI upon WTCCC data have been validated by independent studies. Implementations of the COMBI method are available as a part of the GWASpi toolbox 2.0.

  3. New Results on Quantum Property Testing

    CERN Document Server

    Chakraborty, Sourav; Matsliah, Arie; de Wolf, Ronald

    2010-01-01

    We present several new examples of speed-ups obtainable by quantum algorithms in the context of property testing. First, motivated by sampling algorithms, we consider probability distributions given in the form of an oracle $f:[n]\\to[m]$. Here the probability $\\PP_f(j)$ of an outcome $j\\in[m]$ is the fraction of its domain that $f$ maps to $j$. We give quantum algorithms for testing whether two such distributions are identical or $\\epsilon$-far in $L_1$-norm. Recently, Bravyi, Hassidim, and Harrow~\\cite{BHH10} showed that if $\\PP_f$ and $\\PP_g$ are both unknown (i.e., given by oracles $f$ and $g$), then this testing can be done in roughly $\\sqrt{m}$ quantum queries to the functions. We consider the case where the second distribution is known, and show that testing can be done with roughly $m^{1/3}$ quantum queries, which we prove to be essentially optimal. In contrast, it is known that classical testing algorithms need about $m^{2/3}$ queries in the unknown-unknown case and about $\\sqrt{m}$ queries in the kno...

  4. Machine Learning and Data Mining for Comprehensive Test Ban Treaty Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Russell, S; Vaidya, S

    2009-07-30

    The Comprehensive Test Ban Treaty (CTBT) is gaining renewed attention in light of growing worldwide interest in mitigating risks of nuclear weapons proliferation and testing. Since the International Monitoring System (IMS) installed the first suite of sensors in the late 1990's, the IMS network has steadily progressed, providing valuable support for event diagnostics. This progress was highlighted at the recent International Scientific Studies (ISS) Conference in Vienna in June 2009, where scientists and domain experts met with policy makers to assess the current status of the CTBT Verification System. A strategic theme within the ISS Conference centered on exploring opportunities for further enhancing the detection and localization accuracy of low magnitude events by drawing upon modern tools and techniques for machine learning and large-scale data analysis. Several promising approaches for data exploitation were presented at the Conference. These are summarized in a companion report. In this paper, we introduce essential concepts in machine learning and assess techniques which could provide both incremental and comprehensive value for event discrimination by increasing the accuracy of the final data product, refining On-Site-Inspection (OSI) conclusions, and potentially reducing the cost of future network operations.

  5. Round Robin Fatigue Crack Growth Testing Results

    Science.gov (United States)

    2006-11-01

    Equipment and Setup a. SATEC b. 20 kip (7075-T6); 55 kip (2024-T351) c. Test control hardware/ software i. Hardware: Teststar Ilm ii. Software : Station...Stractlvrai Lif,"e Exteraiocn (CAStLE) DeOartn~ont of Enineering Mechanics, FIC US~.TA/DFFN 1DSA-FA-*rR-2006-10 23-54 arhi Drive, Suite 2J2, U-SAF Academy CO

  6. Results of Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Dieter R

    2003-06-13

    The beam experiments of Final Focus Test Beam (FFTB) started in September 1993 at SLAC, and have produced a 1.7 {micro}m x 75 nm spot of 46 GeV electron beam. A number of new techniques involving two nanometer spot-size monitors have been developed. Several beam diagnostic/tuning schemes are applied to achieve and maintain the small spot. This experiment opens the way toward the nanometer world for future linear colliders.

  7. STRATEGY/RESULT FOR SRF TEST INFRASTRUCTURES

    CERN Document Server

    Weingarten, W

    2011-01-01

    The report summarizes the requirements needed to further develop the technology of RF superconductivity for accelerator application beyond the present state of the art. In relation to emerging European accelerator projects present collaboration schemes are identified. The required test capacities are described and compared with the available ones. Based on a short historical review, the actual performance limits of superconducting cavities are evaluated and measures are proposed to overcome them.

  8. Preliminary Results of Field Emission Cathode Tests

    Science.gov (United States)

    Sovey, James S.; Kovaleski, Scott D.

    2001-01-01

    Preliminary screening tests of field emission cathodes such as chemical vapor deposited (CVD) diamond, textured pyrolytic graphite, and textured copper were conducted at background pressures typical of electric thruster test facilities to assess cathode performance and stability. Very low power electric thrusters which provide tens to hundreds micronewtons of thrust may need field emission neutralizers that have a capability of tens to hundreds of microamperes. From current voltage characteristics, it was found that the CVD diamond and textured metals cathodes clearly satisfied the Fowler-Nordheim emission relation. The CVD diamond and a textured copper cathode had average current densities of 270 and 380 mA/sq cm, respectively, at the beginning-of-life. After a few hours of operation the cathode emission currents degraded by 40 to 75% at background pressures in the 10(exp -5) Pa to 10(exp -4) Pa range. The textured pyrolytic graphite had a modest current density at beginning-of-life of 84 mA/sq cm, but this cathode was the most stable of all. Extended testing of the most promising cathodes is warranted to determine if current degradation is a burn-in effect or whether it is a long-term degradation process. Preliminary experiments with ferroelectric emission cathodes, which are ceramics with spontaneous electric polarization, were conducted. Peak current densities of 30 to 120 mA/sq cm were obtained for pulse durations of about 500 ns in the 10(exp -4) Pa pressure range.

  9. Results of workplace drug testing in Norway

    Directory of Open Access Journals (Sweden)

    Hilde Marie Erøy Lund

    2011-12-01

    Full Text Available Workplace drug testing is less common in Norway than in many other countries. During the period from 2000-2006, 13469 urine or blood samples from employees in the offshore industry, shipping companies and aviation industry were submitted to the Norwegian Institute of Public Health for drug testing. The samples were analysed for benzodiazepines, illicit drugs, muscle relaxants with sedating properties, opioids and z-hypnotics. In total, 2.9% of the samples were positive for one or more substances. During the study period the prevalence decreased for morphine (from 1.9% to 1.1% and increased for amphetamine (from 0.04% to 0.6%, clonazepam (from 0% to 0.1%, methamphetamine (from 0.04% to 0.6%, nitrazepam (from 0% to 0.4% and oxazepam (from 0.5% to 1.3% (p<0.05. There was no significant change in prevalence for the other substances included in the analytical programme. Illicit drugs were significantly associated with lower age (OR: 0.93, p<0.05. This study found low prevalence of drugs among employees in companies with workplace drug testing programmes in Norway.

  10. Machine learning methods for the classification of gliomas: Initial results using features extracted from MR spectroscopy.

    Science.gov (United States)

    Ranjith, G; Parvathy, R; Vikas, V; Chandrasekharan, Kesavadas; Nair, Suresh

    2015-04-01

    With the advent of new imaging modalities, radiologists are faced with handling increasing volumes of data for diagnosis and treatment planning. The use of automated and intelligent systems is becoming essential in such a scenario. Machine learning, a branch of artificial intelligence, is increasingly being used in medical image analysis applications such as image segmentation, registration and computer-aided diagnosis and detection. Histopathological analysis is currently the gold standard for classification of brain tumors. The use of machine learning algorithms along with extraction of relevant features from magnetic resonance imaging (MRI) holds promise of replacing conventional invasive methods of tumor classification. The aim of the study is to classify gliomas into benign and malignant types using MRI data. Retrospective data from 28 patients who were diagnosed with glioma were used for the analysis. WHO Grade II (low-grade astrocytoma) was classified as benign while Grade III (anaplastic astrocytoma) and Grade IV (glioblastoma multiforme) were classified as malignant. Features were extracted from MR spectroscopy. The classification was done using four machine learning algorithms: multilayer perceptrons, support vector machine, random forest and locally weighted learning. Three of the four machine learning algorithms gave an area under ROC curve in excess of 0.80. Random forest gave the best performance in terms of AUC (0.911) while sensitivity was best for locally weighted learning (86.1%). The performance of different machine learning algorithms in the classification of gliomas is promising. An even better performance may be expected by integrating features extracted from other MR sequences. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Investigation of the ElectroPuls E3000 Test Machine for Fatigue Testing of Structural Materials

    Science.gov (United States)

    2016-12-01

    R- ratio of 0.5, the threshold stress intensity factor range is approximately 3.2 MPa·m½. Limitations of the test apparatus were identified under ...Through the course of investigating the behaviour of the test apparatus, limitations were identified under certain conditions, for example...University in 2008. Since 2009 she has worked as an engineer/scientist in the Armour Mechanics and Vehicle Survivability Group and the Structural

  12. Results from some anode wire aging tests

    Energy Technology Data Exchange (ETDEWEB)

    Juricic, I.; Kadyk, J.A.

    1986-01-01

    Using twin setups to test anode wire aging in small gas avalanche tubes, a variety of different gas mixtures were tried and other parameters were varied to study their effects upon the gain drop, nomalized to charge transfer: - 1/Q dI/I. This was found to be quite sensitive to the purity of the gases, and also sensitive to the nominal gain and the gas flow rate. The wire surface material can also significantly affect the aging, as can additives, such as ethanol or water vapor. Certain gas mixtures have been found to be consistent with zero aging at the sensitivity level of this technique.

  13. Test Results of a Phi Monitoring System

    CERN Document Server

    Figueroa, Carlos; Burgos, C; Ferrrando, A; Matorras, Francisco; Molinero, Antonio; Rodriguo, T; Shvachkin, V

    1997-01-01

    The development and tests of a Phi monitoring system prototype designed for the CMS Muon Spectrometer alignment are described. The system, using a sweeping laser beam, defines a light reference plane to be used for the continuous monitoring of the Muon detectors. The performance of the system in the Laboratory was satisfactory. It showed good stability and linearity response behaviour. With the appropriate selection of components it can monitor large range position shifts ( up to 1-2 cm) with good accuracy at long distances ( ~ 60 mu accuracy at 10 m).

  14. SaaS Test Based on Durable X-Machine%基于持久化X-Machine的SaaS测试

    Institute of Scientific and Technical Information of China (English)

    曹阳; 宋连春; 王盈

    2011-01-01

    This paper analyzes the characteristics of Software as a Service(SaaS) software, and proposes a Durable X-Machine(DXM) to model SaaS system to support formal and automatic test.It models a Customer Relationship Management(CRM) SaaS system, and result illustrates that the model can model the SaaS system effectively and construct test case.%分析软件即服务(SaaS)类型软件的特点,在此基础上,提出SaaS系统的持久化X-Machine(DXM)模型,以支持形式化、自动化的SaaS系统测试.以一个客户关系管理(CRM)SaaS系统为实例进行建模,结果证明,DXM模型可以有效地对SaaS系统进行建模并构造测试集.

  15. RESULTS OF INITIAL AMMONIA OXIDATION TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fowley, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-12-30

    This memo presents an experimental survey of aqueous phase chemical processes to remove aqueous ammonia from waste process streams. Ammonia is generated in both the current Hanford waste flowsheet and in future waste processing. Much ammonia will be generated in the Low Activity Waste (LAW) melters.i Testing with simulants in glass melters at Catholic University has demonstrated the significant ammonia production.ii The primary reaction there is the reducing action of sugar on nitrate in the melter cold cap. Ammonia has been found to be a problem in secondary waste stabilization. Ammonia vapors are noxious and destruction of ammonia could reduce hazards to waste treatment process personnel. It is easily evolved especially when ammonia-bearing solutions are adjusted to high pH.

  16. Investigation of the applicability of a tensile testing machine for measuring mucoadhesive strength.

    Science.gov (United States)

    Dyvik, K; Graffner, C

    1992-01-01

    The applicability of a tensile testing machine (M30K, JJ Lloyd Instruments Ltd, GB) is investigated for measuring mucoadhesive strengths. A sample of an aqueous dispersion of a polymer with expected mucoadhesive properties is placed between two homemade discs of polyoxymethylene. The upper disc is mounted on a movable part of the machine while the lower disc is fixed on the stationary frame. A tensile force is submitted and the maximum detachment force at fracture and the adhesion work are estimated from the force displacement curve recorded. In some experiments, native mucous tissue of the large intestine of pigs was glued to the upper disc. Four polymers polycarbophil (Carbopol EX-55), carboxypolymethylene (Carbopol 934P), hydroxypropylmethylcellulose (Methocel K4M), and sodium alginate, are used in five different concentrations. At least three measurements are made of each polymer and concentration. Viscosity and osmolality are determined. By standardizing the time of sample equilibration and the run rate before measurement, it is possible to get good reproducibility of the tensile values. Based on the maximum nominal breaking force and the work consumed, it is concluded that the tensile strength is dependent both on the concentration and the type of polymer. The conclusions are the same independent of whether mucous pig tissue is used, or not. The same rank order in adhesive properties of the polymers is achieved as from using modified surface tensiometers.

  17. Panoramic night vision goggle flight test results

    Science.gov (United States)

    Franck, Douglas L.; Geiselman, Eric E.; Craig, Jeffrey L.

    2000-06-01

    The Panoramic Night Vision Goggle (PNVG) has begun operational test and evaluation with its 100-degree horizontal by 40-degree vertical field of view (FOV) on different aircraft and at different locations. Two configurations of the PNVG are being evaluated. The first configuration design (PNVG I) is very low in profile and fits underneath a visor. PNVG I can be retained by the pilot during ejection. This configuration is interchangeable with a day helmet mounted tracker and display through a standard universal connector. The second configuration (PNVG II) resembles the currently fielded 40-degree circular FOV Aviator Night Vision Imaging Systems (ANVIS) and is designed for non-ejection seat aircraft and ground applications. Pilots completed subjective questionnaires after each flight to compare the capability of the 100-degree horizontal by 40-degree vertical PNVG to the 40-degree circular ANVIS across different operational tasks. This paper discusses current findings and pilot feedback from the flight trials objectives of the next phase of the PNVG program are also discussed.

  18. Results from DR and Instrumentation Test Facilities

    CERN Document Server

    Urakawa, Junji

    2005-01-01

    The KEK Accelerator Test Facility (ATF) is a 1.3GeV storage ring capable of producing ultra-low emittance electron beams and has a beam extraction line for ILC R&D. The ATF has proven to be an ideal place for researches with small, stable beams. 2x1010 single bunch and low current 20 bunch-train with 2.8nsec bunch spacing have been extracted to develop Nano-Cavity BPM’s, FONT, Nano Beam Orbit handling (FEATHER), Optical Diffraction Radiation (ODR) monitor, a precision multi-bunch laser-based beam profile monitor and polarized positron beam generation via backward-Compton scattering by the international collaboration. A set of three cavity BPM's is installed in the ATF extraction line on a set of extremely stiff supports. The KEK group installed another set of three BPM's, with their own support mechanism. The full set of 6 will prove extremely useful. In the DR (Damping Ring), we are researching the fast ion instability, micro-wave instability with four sets of damping wiggler and developing pul...

  19. Acceptability of using electronic vending machines to deliver oral rapid HIV self-testing kits: a qualitative study.

    Directory of Open Access Journals (Sweden)

    Sean D Young

    Full Text Available Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM. Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits.African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience.Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience.Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.

  20. Hard rock tunnel boring machine penetration test as an indicator of chipping process efficiency

    Directory of Open Access Journals (Sweden)

    M.C. Villeneuve

    2017-08-01

    Full Text Available The transition from grinding to chipping can be observed in tunnel boring machine (TBM penetration test data by plotting the penetration rate (distance/revolution against the net cutter thrust (force per cutter over the full range of penetration rates in the test. Correlating penetration test data to the geological and geomechanical characteristics of rock masses through which a penetration test is conducted provides the ability to reveal the efficiency of the chipping process in response to changing geological conditions. Penetration test data can also be used to identify stress-induced tunnel face instability. This research shows that the strength of the rock is an important parameter for controlling how much net cutter thrust is required to transition from grinding to chipping. It also shows that the geological characteristics of a rock will determine how efficient chipping occurs once it has begun. In particular, geological characteristics that lead to efficient fracture propagation, such as fabric and mica contents, will lead to efficient chipping. These findings will enable a better correlation between TBM performance and geological conditions for use in TBM design, as a basis for contractual payments where penetration rate dominates the excavation cycle and in further academic investigations into the TBM excavation process.

  1. Uncertainty in in-place filter test results

    Energy Technology Data Exchange (ETDEWEB)

    Scripsick, R.C.; Beckman, R.J.; Mokler, B.V.

    1996-12-31

    Some benefits of accounting for uncertainty in in-place filter test results are explored. Information the test results provide relative to system performance acceptance limits is evaluated in terms of test result uncertainty. An expression for test result uncertainty is used to estimate uncertainty in in-place filter tests on an example air cleaning system. Modifications to the system test geometry are evaluated in terms of effects on test result uncertainty.

  2. Status of field testing of a small absorption refrigerating machine; Stand der Felderprobung einer Kleinabsorptions-Kaeltemaschine

    Energy Technology Data Exchange (ETDEWEB)

    Safarik, M.; Richter, L. [Institut fuer Luft- und Kaeltetechnik GmbH, Dresden (Germany); Weidner, G.; Otto, M. [EAW Energieanlagenbau GmbH, Westenfeld (Germany); Naumann, F.; Moeckel, F. [Hochschule fuer Technik, Wirtschaft und Kultur Leipzig (F.H.) (Germany)

    2005-07-01

    The performance efficiency and the reliability of the small absorption refrigerating machine WGRACL SE 15 are investigated by the scientific study of three plants in real operation. The systems distinguish themselves by peripheral components which allow gaining experience with the use of absorption refrigerating machines under different frame conditions. One plant could already be operated with good results during the summer 2005. Further results are expected for the cold season 2006. (orig.)

  3. Inflatable Wing Design Parameter Optimization Using Orthogonal Testing and Support Vector Machines

    Institute of Scientific and Technical Information of China (English)

    WANG Zhifei; WANG Hua

    2012-01-01

    The robust parameter design method is a traditional approach to robust experimental design that seeks to obtain the optimal combination of factors/levels.To overcome some of the defects of the inflatable wing parameter design method,this paper proposes an optimization design scheme based on orthogonal testing and support vector machines (SVMs).Orthogonal testing design is used to estimate the appropriate initial value and variation domain of each variable to decrease the number of iterations and improve the identification accuracy and efficiency.Orthogonal tests consisting of three factors and three levels are designed to analyze the parameters of pressure,uniform applied load and the number of chambers that affect the bending response of inflatable wings.An SVM intelligent model is established and limited orthogonal test swatches are studied.Thus,the precise relationships between each parameter and product quality features,as well the signal-to-noise ratio (SNR),can be obtained.This can guide general technological design optimization.

  4. Biomarkers of Eating Disorders Using Support Vector Machine Analysis of Structural Neuroimaging Data: Preliminary Results.

    Science.gov (United States)

    Cerasa, Antonio; Castiglioni, Isabella; Salvatore, Christian; Funaro, Angela; Martino, Iolanda; Alfano, Stefania; Donzuso, Giulia; Perrotta, Paolo; Gioia, Maria Cecilia; Gilardi, Maria Carla; Quattrone, Aldo

    2015-01-01

    Presently, there are no valid biomarkers to identify individuals with eating disorders (ED). The aim of this work was to assess the feasibility of a machine learning method for extracting reliable neuroimaging features allowing individual categorization of patients with ED. Support Vector Machine (SVM) technique, combined with a pattern recognition method, was employed utilizing structural magnetic resonance images. Seventeen females with ED (six with diagnosis of anorexia nervosa and 11 with bulimia nervosa) were compared against 17 body mass index-matched healthy controls (HC). Machine learning allowed individual diagnosis of ED versus HC with an Accuracy ≥ 0.80. Voxel-based pattern recognition analysis demonstrated that voxels influencing the classification Accuracy involved the occipital cortex, the posterior cerebellar lobule, precuneus, sensorimotor/premotor cortices, and the medial prefrontal cortex, all critical regions known to be strongly involved in the pathophysiological mechanisms of ED. Although these findings should be considered preliminary given the small size investigated, SVM analysis highlights the role of well-known brain regions as possible biomarkers to distinguish ED from HC at an individual level, thus encouraging the translational implementation of this new multivariate approach in the clinical practice.

  5. Biomarkers of Eating Disorders Using Support Vector Machine Analysis of Structural Neuroimaging Data: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Antonio Cerasa

    2015-01-01

    Full Text Available Presently, there are no valid biomarkers to identify individuals with eating disorders (ED. The aim of this work was to assess the feasibility of a machine learning method for extracting reliable neuroimaging features allowing individual categorization of patients with ED. Support Vector Machine (SVM technique, combined with a pattern recognition method, was employed utilizing structural magnetic resonance images. Seventeen females with ED (six with diagnosis of anorexia nervosa and 11 with bulimia nervosa were compared against 17 body mass index-matched healthy controls (HC. Machine learning allowed individual diagnosis of ED versus HC with an Accuracy ≥ 0.80. Voxel-based pattern recognition analysis demonstrated that voxels influencing the classification Accuracy involved the occipital cortex, the posterior cerebellar lobule, precuneus, sensorimotor/premotor cortices, and the medial prefrontal cortex, all critical regions known to be strongly involved in the pathophysiological mechanisms of ED. Although these findings should be considered preliminary given the small size investigated, SVM analysis highlights the role of well-known brain regions as possible biomarkers to distinguish ED from HC at an individual level, thus encouraging the translational implementation of this new multivariate approach in the clinical practice.

  6. Prediction of Machine Tool Condition Using Support Vector Machine

    Science.gov (United States)

    Wang, Peigong; Meng, Qingfeng; Zhao, Jian; Li, Junjie; Wang, Xiufeng

    2011-07-01

    Condition monitoring and predicting of CNC machine tools are investigated in this paper. Considering the CNC machine tools are often small numbers of samples, a condition predicting method for CNC machine tools based on support vector machines (SVMs) is proposed, then one-step and multi-step condition prediction models are constructed. The support vector machines prediction models are used to predict the trends of working condition of a certain type of CNC worm wheel and gear grinding machine by applying sequence data of vibration signal, which is collected during machine processing. And the relationship between different eigenvalue in CNC vibration signal and machining quality is discussed. The test result shows that the trend of vibration signal Peak-to-peak value in surface normal direction is most relevant to the trend of surface roughness value. In trends prediction of working condition, support vector machine has higher prediction accuracy both in the short term ('One-step') and long term (multi-step) prediction compared to autoregressive (AR) model and the RBF neural network. Experimental results show that it is feasible to apply support vector machine to CNC machine tool condition prediction.

  7. A small-sample multivariate kernel machine test for microbiome association studies.

    Science.gov (United States)

    Zhan, Xiang; Tong, Xingwei; Zhao, Ni; Maity, Arnab; Wu, Michael C; Chen, Jun

    2017-04-01

    High-throughput sequencing technologies have enabled large-scale studies of the role of the human microbiome in health conditions and diseases. Microbial community level association test, as a critical step to establish the connection between overall microbiome composition and an outcome of interest, has now been routinely performed in many studies. However, current microbiome association tests all focus on a single outcome. It has become increasingly common for a microbiome study to collect multiple, possibly related, outcomes to maximize the power of discovery. As these outcomes may share common mechanisms, jointly analyzing these outcomes can amplify the association signal and improve statistical power to detect potential associations. We propose the multivariate microbiome regression-based kernel association test (MMiRKAT) for testing association between multiple continuous outcomes and overall microbiome composition, where the kernel used in MMiRKAT is based on Bray-Curtis or UniFrac distance. MMiRKAT directly regresses all outcomes on the microbiome profiles via a semiparametric kernel machine regression framework, which allows for covariate adjustment and evaluates the association via a variance-component score test. Because most of the current microbiome studies have small sample sizes, a novel small-sample correction procedure is implemented in MMiRKAT to correct for the conservativeness of the association test when the sample size is small or moderate. The proposed method is assessed via simulation studies and an application to a real data set examining the association between host gene expression and mucosal microbiome composition. We demonstrate that MMiRKAT is more powerful than large sample based multivariate kernel association test, while controlling the type I error. A free implementation of MMiRKAT in R language is available at http://research.fhcrc.org/wu/en.html.

  8. Test report on the machine-mounted continuous respirable dust monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kissell, F.N.; Thimons, E.D. [Pittsburgh Research Laboratory, Pittsburgh, PA (USA). National Institute for Occupational Safety and Health

    2001-07-01

    The machine-mounted continuous respirable dust monitor (MMCRDM) is a fixed-location area sampling device developed for possible use at the working face of an underground coal mine. This device, based on proprietary technology known as the tapered element oscillating microbalance, has evolved over the past eight years through a cooperative effort of the former Bureau of Mines, MSHA, and the Rupprecht & Patashnick Company in Albany, NY. The capability to measure respirable coal mine dust levels on a continuous basis, rather than depending solely on periodic samples obtained from the traditional coal mine dust samplers, has been a goal in the mining industry for nearly two decades. Recently, an extensive series of laboratory and underground tests was conducted by NIOSH with the cooperation of MSHA and coal operators to test the performance of the MMCRDM. In preliminary laboratory testing, the MMCRDM seemed to work well. However, in every underground test, when compared to reference samplers placed close to the inlet, the MMCRDM failed to meet the 25% accuracy criterion specified in the contract under which it was developed. Two reasons explain this failure: first, in most tests the bias (the relative discrepancy between the average MMCRDM concentration and the average reference sampler concentration) was too great. Second, the variability of the samplers used for reference comparison was too large. Finally, the underground testing of the MMCRDMs showed that they are quite unreliable at this stage of development. In the majority of mine tests, no more than 10 shifts of data were taken before the MMCRDM failed to function properly. Major breakdowns, requiring the return of the MMCRDM to the factory for repairs, occurred on average every 28 days. To be considered mine-worthy, MMCRDM reliability must be substantially improved. 6 refs., 7 figs.

  9. Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from Radio Frequency plasma) experiment: tests in BATMAN (BAvarian Test Machine for Negative ions).

    Science.gov (United States)

    Brombin, M; Spolaore, M; Serianni, G; Pomaro, N; Taliercio, C; Dalla Palma, M; Pasqualotto, R; Schiesko, L

    2014-11-01

    A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors' holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

  10. Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

    Energy Technology Data Exchange (ETDEWEB)

    Brombin, M., E-mail: matteo.brombin@igi.cnr.it; Spolaore, M.; Serianni, G.; Pomaro, N.; Taliercio, C.; Palma, M. Dalla; Pasqualotto, R. [Consorzio RFX, Corso Stati Uniti 4, I-35127 Padova (Italy); Schiesko, L. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2014-11-15

    A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors’ holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

  11. Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

    Science.gov (United States)

    Brombin, M.; Spolaore, M.; Serianni, G.; Pomaro, N.; Taliercio, C.; Palma, M. Dalla; Pasqualotto, R.; Schiesko, L.

    2014-11-01

    A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors' holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

  12. Integrating Symbolic and Statistical Methods for Testing Intelligent Systems Applications to Machine Learning and Computer Vision

    Energy Technology Data Exchange (ETDEWEB)

    Jha, Sumit Kumar [University of Central Florida, Orlando; Pullum, Laura L [ORNL; Ramanathan, Arvind [ORNL

    2016-01-01

    Embedded intelligent systems ranging from tiny im- plantable biomedical devices to large swarms of autonomous un- manned aerial systems are becoming pervasive in our daily lives. While we depend on the flawless functioning of such intelligent systems, and often take their behavioral correctness and safety for granted, it is notoriously difficult to generate test cases that expose subtle errors in the implementations of machine learning algorithms. Hence, the validation of intelligent systems is usually achieved by studying their behavior on representative data sets, using methods such as cross-validation and bootstrapping.In this paper, we present a new testing methodology for studying the correctness of intelligent systems. Our approach uses symbolic decision procedures coupled with statistical hypothesis testing to. We also use our algorithm to analyze the robustness of a human detection algorithm built using the OpenCV open-source computer vision library. We show that the human detection implementation can fail to detect humans in perturbed video frames even when the perturbations are so small that the corresponding frames look identical to the naked eye.

  13. VISUALIZATION OF THREE-DIMENSIONAL DATA FIELD AND ITS APPLICATION IN MACHINE TESTING

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In order to realize visualization of three-dimensional data field (TDDF) in instrument, two methods of visualization of TDDF and the usual manner of quick graphic and image processing are analyzed. And how to use OpenGL technique and the characteristic of analyzed data to construct a TDDF, the ways of reality processing and interactive processing are described. Then the medium geometric element and a related realistic model are constructed by means of the first algorithm.Models obtained for attaching the third dimension in three-dimensional data field are presented. An example for TDDF realization of machine measuring is provided. The analysis of resultant graphic indicates that the three-dimensional graphics built by the method developed is featured by good reality, fast processing and strong interaction

  14. Machining Test Specimens from Harvested Zion RPV Segments for Through Wall Attenuation Studies

    Energy Technology Data Exchange (ETDEWEB)

    Rosseel, Thomas M [ORNL; Sokolov, Mikhail A [ORNL; Nanstad, Randy K [ORNL

    2015-01-01

    The decommissioning of the Zion Units 1 and 2 Nuclear Generating Station (NGS) in Zion, Illinois presents a special opportunity for developing a better understanding of materials degradation and other issues associated with extending the lifetime of existing Nuclear Power Plants (NPPs) beyond 60 years of service. In support of extended service and current operations of the US nuclear reactor fleet, the Oak Ridge National Laboratory (ORNL), through the Department of Energy (DOE), Light Water Reactor Sustainability (LWRS) Program, is coordinating and contracting with Zion Solutions, LLC, a subsidiary of Energy Solutions, the selective procurement of materials, structures, and components from the decommissioned reactors. In this paper, we will discuss the acquisition of segments of the Zion Unit 2 Reactor Pressure Vessel (RPV), the cutting of these segments into sections and blocks from the beltline and upper vertical welds and plate material, the current status of machining those blocks into mechanical (Charpy, compact tension, and tensile) test specimens and coupons for chemical and microstructural (TEM, APT, SANS, and nano indention) characterization, as well as the current test plans and possible collaborative projects. Access to service-irradiated RPV welds and plate sections will allow through wall attenuation studies to be performed, which will be used to assess current radiation damage models (Rosseel et al. (2012) and Rosseel et al. (2015)).

  15. Cleaning of Free Machining Brass

    Energy Technology Data Exchange (ETDEWEB)

    Shen, T

    2005-12-29

    We have investigated four brightening treatments proposed by two cleaning vendors for cleaning free machining brass. The experimental results showed that none of the proposed brightening treatments passed the swipe test. Thus, we maintain the recommendation of not using the brightening process in the cleaning of free machining brass for NIF application.

  16. Synthetic tests of passive microwave brightness temperature assimilation over snow covered land using machine learning algorithms

    Science.gov (United States)

    Forman, B. A.

    2015-12-01

    A novel data assimilation framework is evaluated that assimilates passive microwave (PMW) brightness temperature (Tb) observations into an advanced land surface model for the purpose of improving snow depth and snow water equivalent (SWE) estimates across regional- and continental-scales. The multifrequency, multipolarization framework employs machine learning algorithms to predict PMW Tb as a function of land surface model state information and subsequently merges the predicted PMW Tb with observed PMW Tb from the Advanced Microwave Scanning Radiometer (AMSR-E). The merging procedure is predicated on conditional probabilities computed within a Bayesian statistical framework using either an Ensemble Kalman Filter (EnKF) or an Ensemble Kalman Smoother (EnKS). The data assimilation routine produces a conditioned (updated) estimate of modeled SWE that is more accurate and contains less uncertainty than the model without assimilation. A synthetic case study is presented for select locations in North America that compares model results with and without assimilation against synthetic observations of snow depth and SWE. It is shown that the data assimilation framework improves modeled estimates of snow depth and SWE during both the accumulation and ablation phases of the snow season. Further, it is demonstrated that the EnKS outperforms the EnKF implementation due to its ability to better modulate high frequency noise into the conditioned estimates. The overarching findings from this study demonstrate the feasibility of machine learning algorithms for use as an observation model operator within a data assimilation framework in order to improve model estimates of snow depth and SWE across regional- and continental-scales.

  17. Advanced Machine learning Algorithm Application for Rotating Machine Health Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kanemoto, Shigeru; Watanabe, Masaya [The University of Aizu, Aizuwakamatsu (Japan); Yusa, Noritaka [Tohoku University, Sendai (Japan)

    2014-08-15

    The present paper tries to evaluate the applicability of conventional sound analysis techniques and modern machine learning algorithms to rotating machine health monitoring. These techniques include support vector machine, deep leaning neural network, etc. The inner ring defect and misalignment anomaly sound data measured by a rotating machine mockup test facility are used to verify the above various kinds of algorithms. Although we cannot find remarkable difference of anomaly discrimination performance, some methods give us the very interesting eigen patterns corresponding to normal and abnormal states. These results will be useful for future more sensitive and robust anomaly monitoring technology.

  18. Manufacturing and test of 2G-HTS coils for rotating machines: Challenges, conductor requirements, realization

    Energy Technology Data Exchange (ETDEWEB)

    Oomen, Marijn, E-mail: marijn.oomen@siemens.com [Siemens AG, Corporate Technology, CT T DE HW4, PO Box 3220, 91050 Erlangen (Germany); Herkert, Werner; Bayer, Dietmar; Kummeth, Peter; Nick, Wolfgang; Arndt, Tabea [Siemens AG, Corporate Technology, CT T DE HW4, PO Box 3220, 91050 Erlangen (Germany)

    2012-11-20

    We investigate the use of 2nd-generation High-Temperature Superconductors (2G-HTSs) in the rotors of electrical motors and generators. For these devices the conductor must be wound into robust impregnated coils, which are operated in vacuum at temperatures around 30 K, in strong magnetic fields of about 2T. Differences in thermal contraction between the coil former, conductor constituents, impregnation resin, bandage and heat-sink materials (assembled at room temperature) cause mechanical stresses at operating temperature. Rotating-machine operation adds Lorentz forces and challenging centripetal accelerations up to thousands of g. Second generation-HTS conductors withstand large tensile stresses in axial direction and compression in normal direction. However, shear stresses, axial compression, and tension normal to the conductor can cause degradation in superconducting properties. Such stresses can be mitigated by correct choice of materials, coil lay-out and manufacturing process. A certain stress level will remain, which the conductor must withstand. We have manufactured many impregnated round and race-track coils, using different 2G-HTS conductors, and tested them at temperatures from 25 K to 77 K. Degradation of the superconductor in early coils was traced to the mentioned differences in thermal contraction, and was completely avoided in coils produced later. We will discuss appropriate coil-winding techniques to assure robust and reliable superconductor performance.

  19. Manufacturing and test of 2G-HTS coils for rotating machines: Challenges, conductor requirements, realization

    Science.gov (United States)

    Oomen, Marijn; Herkert, Werner; Bayer, Dietmar; Kummeth, Peter; Nick, Wolfgang; Arndt, Tabea

    2012-11-01

    We investigate the use of 2nd-generation High-Temperature Superconductors (2G-HTSs) in the rotors of electrical motors and generators. For these devices the conductor must be wound into robust impregnated coils, which are operated in vacuum at temperatures around 30 K, in strong magnetic fields of about 2T. Differences in thermal contraction between the coil former, conductor constituents, impregnation resin, bandage and heat-sink materials (assembled at room temperature) cause mechanical stresses at operating temperature. Rotating-machine operation adds Lorentz forces and challenging centripetal accelerations up to thousands of g. Second generation-HTS conductors withstand large tensile stresses in axial direction and compression in normal direction. However, shear stresses, axial compression, and tension normal to the conductor can cause degradation in superconducting properties. Such stresses can be mitigated by correct choice of materials, coil lay-out and manufacturing process. A certain stress level will remain, which the conductor must withstand. We have manufactured many impregnated round and race-track coils, using different 2G-HTS conductors, and tested them at temperatures from 25 K to 77 K. Degradation of the superconductor in early coils was traced to the mentioned differences in thermal contraction, and was completely avoided in coils produced later. We will discuss appropriate coil-winding techniques to assure robust and reliable superconductor performance.

  20. Development of a machine protection system for the Superconducting Beam Test Facility at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Warner, A.; Carmichael, L.; Church, M.; Neswold, R.; /Fermilab

    2011-09-01

    Fermilab's Superconducting RF Beam Test Facility currently under construction will produce electron beams capable of damaging the acceleration structures and the beam line vacuum chambers in the event of an aberrant accelerator pulse. The accelerator is being designed with the capability to operate with up to 3000 bunches per macro-pulse, 5Hz repetition rate and 1.5 GeV beam energy. It will be able to sustain an average beam power of 72 KW at the bunch charge of 3.2 nC. Operation at full intensity will deposit enough energy in niobium material to approach the melting point of 2500 C. In the early phase with only 3 cryomodules installed the facility will be capable of generating electron beam energies of 810 MeV and an average beam power that approaches 40 KW. In either case a robust Machine Protection System (MPS) is required to mitigate effects due to such large damage potentials. This paper will describe the MPS system being developed, the system requirements and the controls issues under consideration.

  1. Multispectral imaging burn wound tissue classification system: a comparison of test accuracies between several common machine learning algorithms

    Science.gov (United States)

    Squiers, John J.; Li, Weizhi; King, Darlene R.; Mo, Weirong; Zhang, Xu; Lu, Yang; Sellke, Eric W.; Fan, Wensheng; DiMaio, J. Michael; Thatcher, Jeffrey E.

    2016-03-01

    The clinical judgment of expert burn surgeons is currently the standard on which diagnostic and therapeutic decisionmaking regarding burn injuries is based. Multispectral imaging (MSI) has the potential to increase the accuracy of burn depth assessment and the intraoperative identification of viable wound bed during surgical debridement of burn injuries. A highly accurate classification model must be developed using machine-learning techniques in order to translate MSI data into clinically-relevant information. An animal burn model was developed to build an MSI training database and to study the burn tissue classification ability of several models trained via common machine-learning algorithms. The algorithms tested, from least to most complex, were: K-nearest neighbors (KNN), decision tree (DT), linear discriminant analysis (LDA), weighted linear discriminant analysis (W-LDA), quadratic discriminant analysis (QDA), ensemble linear discriminant analysis (EN-LDA), ensemble K-nearest neighbors (EN-KNN), and ensemble decision tree (EN-DT). After the ground-truth database of six tissue types (healthy skin, wound bed, blood, hyperemia, partial injury, full injury) was generated by histopathological analysis, we used 10-fold cross validation to compare the algorithms' performances based on their accuracies in classifying data against the ground truth, and each algorithm was tested 100 times. The mean test accuracy of the algorithms were KNN 68.3%, DT 61.5%, LDA 70.5%, W-LDA 68.1%, QDA 68.9%, EN-LDA 56.8%, EN-KNN 49.7%, and EN-DT 36.5%. LDA had the highest test accuracy, reflecting the bias-variance tradeoff over the range of complexities inherent to the algorithms tested. Several algorithms were able to match the current standard in burn tissue classification, the clinical judgment of expert burn surgeons. These results will guide further development of an MSI burn tissue classification system. Given that there are few surgeons and facilities specializing in burn care

  2. 49 CFR 199.109 - Review of drug testing results.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Review of drug testing results. 199.109 Section... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.109 Review of drug testing results. (a) MRO appointment. Each operator shall...

  3. Rotating electrical machines. Part 2: Methods for determining losses and efficiency of rotating electrical machinery from tests (excluding machines for traction vehicles)

    CERN Document Server

    International Electrotechnical Commission. Geneva

    1972-01-01

    Applies to d.c. machines and to a.c. synchronous and induction machines. The principles can be applied to other types of machines such as rotary converters, a.c. commutator motors and single-phase induction motors for which other methods of determining losses are used.

  4. False positive test results for pheochromocytoma from 2000 to 2008.

    Science.gov (United States)

    Yu, R; Wei, M

    2010-10-01

    Testing for pheochromocytoma becomes more frequent in clinical practice. False positive test results may cause patient anxiety and unnecessary imaging studies. The data on false positive results for pheochromocytoma in routine clinical practice are lacking. To examine the prevalence of false positive results and to reveal the clinical features and laboratory tests of patients with markedly elevated but false positive test results, a database of tests for pheochromocytoma at a large general hospital between 2000 and 2008 was reviewed. Of 1,896 patients tested, 417 (22.0%) had at least one abnormal test result and 66 (3.5%) had markedly elevated results. 24 patients with markedly elevated but false positive results received 65 imaging studies and 1 adrenalectomy. The causes of the misleading results included physiological variations (33%), laboratory errors (29%), and drug interference with measurement (21%). The false positive rate of a markedly elevated result was lowest for vanillylmandelic acid (9%) and highest for urine metanephrines (50%) (p = 0.03). Nearly half of all test results were normal and 79% of patients had at least one normal result. Therefore false positive test results for pheochromocytoma are rather common. Markedly elevated but false positive test results can potentially be avoided by judicious selection of patients and tests. Pretest risk, physiological variations of catecholamine levels, laboratory errors, and drug interference should be considered in interpreting abnormal test results. © J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York.

  5. Embedded software simulation testing environment based on virtual machine%基于虚拟机的嵌人式软件仿真测试环境

    Institute of Scientific and Technical Information of China (English)

    殷永峰; 刘斌; 王志

    2011-01-01

    In order to enhance the quality and reliability of embedded software, an embedded software simulation testing environment based on virtual machine was proposed. The virtual machine technology was introduced into the simulation testing field of embedded software, and the constitution principle of embedded software simulation testing environment was introduced. In addition, the virtual machine technology was analyzed, and an embedded software simulation testing virtual machine (ESSTVM) based on an extended program-transplantation virtual machine model was proposed. And the design scheme for the memory management and instruction system was presented. The ESSTVM was applied to the design of avionics embedded software simulation testing environment (AESSTE), and the system structure of the testing environment was studied. Moreover, the design and realization of both testing development and testing execution systems were elaborated, and the transportability of AESSTE was analyzed. The analysis results show that the proposed method can effectively improve the universality, transportability and maintainability of embedded software testing environment.%为了提高嵌入式软件的质量和可靠性,提出了一种基于虚拟机的嵌入式软件仿真测试环境.将虚拟机技术引入到嵌入式软件仿真测试领域中,介绍了嵌入式软件仿真测试环境的构成原理,并对虚拟机技术进行了分析,提出一种基于程序移植虚拟机模型扩展的嵌入式软件仿真测试虚拟机(ESSTVM),给出了内存管理和指令系统的设计方案.将ESSTVM应用到航电嵌入式软件系统测试环境AESSTE设计中,研究了该测试环境的体系结构,阐述了测试开发系统及测试执行系统的设计与实现,并对AESSTE的可移植性进行了分析.分析结果表明,该方法能有效提高嵌入式软件测试环境的通用性、可移植性和可维护性.

  6. The SNS Machine Protection System Early Commissioning Results and Future Plans

    CERN Document Server

    Sibley, Coles; Jones, Alan; Justice, Thomas A; Thompson, Dave H

    2005-01-01

    The Spallation Neutron Source under construction in Oak Ridge TN has commissioned low power beam up to 187 Mev. The number of MPS inputs is about 20% of the final number envisioned. Start-up problems, including noise and false trips, have largely been overcome by replacing copper with fiber and adding filters as required. Initial recovery time from Machine Protection System (MPS) trips was slow due to a hierarchy of latched inputs in the system: at the device level, at the MPS input layer, and at the operator interface level. By reprogramming the MPS FPGA such that all resets were at the input devices, MPS availability improved to acceptable levels. For early commissioning MPS inputs will be limited to beam line devices that will prohibit beam operation. For later operation, the number of MPS inputs will increase both software alarms and less intrusive MPS inputs such as steering magnets are implemented. Two upgrades to SNS are on the horizon: a 3 MW upgrade and a second target station. Although these are yea...

  7. Effect of Micro Electrical Discharge Machining Process Conditions on Tool Wear Characteristics: Results of an Analytic Study

    DEFF Research Database (Denmark)

    Puthumana, Govindan; P., Rajeev

    2016-01-01

    Micro electrical discharge machining is one of the established techniques to manufacture high aspect ratio features on electrically conductive materials. This paper presents the results and inferences of an analytical study for estimating theeffect of process conditions on tool electrode wear...... characteristicsin micro-EDM process. A new approach with two novel factors anticipated to directly control the material removal mechanism from the tool electrode are proposed; using discharge energyfactor (DEf) and dielectric flushing factor (DFf). The results showed that the correlation between the tool wear rate...

  8. Analysis of Factors Influencing Measurement Accuracy of Al Alloy Tensile Test Results

    Science.gov (United States)

    Podgornik, Bojan; Žužek, Borut; Sedlaček, Marko; Kevorkijan, Varužan; Hostej, Boris

    2016-02-01

    In order to properly use materials in design, a complete understanding of and information on their mechanical properties, such as yield and ultimate tensile strength must be obtained. Furthermore, as the design of automotive parts is constantly pushed toward higher limits, excessive measuring uncertainty can lead to unexpected premature failure of the component, thus requiring reliable determination of material properties with low uncertainty. The aim of the present work was to evaluate the effect of different metrology factors, including the number of tested samples, specimens machining and surface quality, specimens input diameter, type of testing and human error on the tensile test results and measurement uncertainty when performed on 2xxx series Al alloy. Results show that the most significant contribution to measurement uncertainty comes from the number of samples tested, which can even exceed 1 %. Furthermore, moving from experimental laboratory conditions to very intense industrial environment further amplifies measurement uncertainty, where even if using automated systems human error cannot be neglected.

  9. Unsupervised nonlinear dimensionality reduction machine learning methods applied to multiparametric MRI in cerebral ischemia: preliminary results

    Science.gov (United States)

    Parekh, Vishwa S.; Jacobs, Jeremy R.; Jacobs, Michael A.

    2014-03-01

    The evaluation and treatment of acute cerebral ischemia requires a technique that can determine the total area of tissue at risk for infarction using diagnostic magnetic resonance imaging (MRI) sequences. Typical MRI data sets consist of T1- and T2-weighted imaging (T1WI, T2WI) along with advanced MRI parameters of diffusion-weighted imaging (DWI) and perfusion weighted imaging (PWI) methods. Each of these parameters has distinct radiological-pathological meaning. For example, DWI interrogates the movement of water in the tissue and PWI gives an estimate of the blood flow, both are critical measures during the evolution of stroke. In order to integrate these data and give an estimate of the tissue at risk or damaged; we have developed advanced machine learning methods based on unsupervised non-linear dimensionality reduction (NLDR) techniques. NLDR methods are a class of algorithms that uses mathematically defined manifolds for statistical sampling of multidimensional classes to generate a discrimination rule of guaranteed statistical accuracy and they can generate a two- or three-dimensional map, which represents the prominent structures of the data and provides an embedded image of meaningful low-dimensional structures hidden in their high-dimensional observations. In this manuscript, we develop NLDR methods on high dimensional MRI data sets of preclinical animals and clinical patients with stroke. On analyzing the performance of these methods, we observed that there was a high of similarity between multiparametric embedded images from NLDR methods and the ADC map and perfusion map. It was also observed that embedded scattergram of abnormal (infarcted or at risk) tissue can be visualized and provides a mechanism for automatic methods to delineate potential stroke volumes and early tissue at risk.

  10. SOURCES OF DIFFERENCES IN CALCULATIONS AND EXPERIMENTAL TEST RESULTS OF FATIGUE LIFE OF STRUCTURAL ELEMENTS

    Directory of Open Access Journals (Sweden)

    Józef SZALA

    2014-06-01

    Full Text Available Calculation results are the base for evaluation of fatigue life of structural elements during machine design processes. It results from the fact that there are no material objects in the phase of existence of a product. Reliability of tests results is an essential element in the calculation fatigue life evaluation method and it can be evaluated by comparison of the results with experimental ones. In the paper there was performed an analysis of the chosen factors essentially influencing conformity of calculation results and experimental test ones connected with basic elements of a calculation algorithm including: - elaboration and analysis of service loadings of a structural element, - determination and analysis of cyclic properties of structural elements, - selection of fatigue damage accumulation hypothesis being a description of fatigue life processes. The mentioned analysis was illustrated with examples of fatigue life tests performed in the Machine Design Department of the University of Technology and Agriculture within the research grant no. 2221/B/T02/2010/39 financed by The Ministry of Science and Higher Education and National Science Centre.

  11. Diamond Particle Detector Properties during High Fluence Material Damage Tests and their Future Applications for Machine Protection in the LHC

    CERN Document Server

    Burkart, F; Borburgh, J; Dehning, B; Di Castro, M; Griesmayer, E; Lechner, A; Lendaro, J; Loprete, F; Losito, R; Montesano, S; Schmidt, R; Wollmann, D; Zerlauth, M

    2013-01-01

    Experience with LHC machine protection (MP) during the last three years of operation shows that the MP systems sufficiently protect the LHC against damage in case of failures leading to beam losses with a time constant exceeding 1ms. An unexpected fast beam loss mechanism, called UFOs [1], was observed, which could potentially quench superconducting magnets. For such fast losses, but also for better understanding of slower losses, an improved understanding of the loss distribution within a bunch train is required [2]. Diamond particle detectors with bunch-by-bunch resolution and high dynamic range have been developed and successfully tested in the LHC and in experiments to quantify the damage limits of LHC components. This paper will focus on experience gained in use of diamond detectors. The properties of these detectors were measured during high-fluence material damage tests in CERN’s Hi-RadMat facility. The results will be discussed and compared to the cross-calibration with FLUKA simulations. Future app...

  12. 49 CFR 219.605 - Positive drug test results; procedures.

    Science.gov (United States)

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2010-10-01 2010-10-01 false Positive drug test results; procedures. 219.605...

  13. Sickle Cell Trait in Blacks Can Skew Diabetes Test Results

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_163463.html Sickle Cell Trait in Blacks Can Skew Diabetes Test Results ... less accurate in black people who have the sickle cell anemia trait, a new study says. The test ...

  14. Effects of testing conditions on conceptual survey results

    Directory of Open Access Journals (Sweden)

    Lin Ding

    2008-06-01

    Full Text Available Pre-testing and post-testing is a commonly used method in Physics Education Research to assess student learning gains. It is well recognized in the community that timings and incentives in delivering conceptual tests can impact test results. However, it is difficult to control these variables across different studies. As a common practice, a pre-test is often administered either at or near the beginning of a course, while a post-test can be given either at or near the end of a course. Also, in conducting such tests there often is no norm as to whether incentives should be offered to students. Because these variations can significantly affect test results, it is important to study and document their impact. We analyzed five years of data that were collected at The Ohio State University from over 2100 students, who took both the pre-test and post-test of the Conceptual Survey of Electricity and Magnetism under various timings and incentives. We observed that the actual time frame for giving a test has a marked effect on the test results and that incentive granting also has a significant influence on test outcomes. These results suggest that one should carefully monitor and document the conditions under which tests are administered.

  15. Assessment of Partially Conductive Cracks from Eddy Current Non-Destructive Testing Signals using Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Ladislav Janousek

    2015-01-01

    Full Text Available This paper deals with a three-dimensional non-destructive evaluation of partially conductive cracks from eddy current testing signals. An SUS316L plate specimen containing a crack is non-destructively inspected by the eddy current method using numerical simulations. An extensive database of eddy current response signals is prepared while dimensional parameters of a crack together with its partial conductivity are varied in wide ranges. A Support Vector Machine classification algorithm is employed to solve the electromagnetic inverse problem. The acquired signals are employed for training the algorithm and for testing its performance. It is demonstrated that the Support Vector Machine algorithm is able to properly classify detected defects into proper classes with very high probability even the partial conductivity of a detected crack together with its width are unknown.

  16. Determination of the Thermal Expansion Coefficient of Concrete at Early Ages by Using Temperature-stress Testing Machine

    Institute of Scientific and Technical Information of China (English)

    HUO Kaicheng; SHUI Zhonghe; LI Yue

    2006-01-01

    By using the uptodate temperatuer-stress testing machine, the thermal expansion coefficient of concrete at early ages was studied and indicative conclusions were achieved: temperature rising due to hydration heat is not directly correlated with cracking, but the temperature and stress evolution process should be taken into consideration in the same time. Proper chemical admixtures and mineral compositions can improve the mechanical properties of concrete such as thermal expansion coefficient, which is very indicative in practice.

  17. IPEM Report No 84: Guidelines for the Testing and Calibration of Physiotherapy Ultrasound Machines

    Energy Technology Data Exchange (ETDEWEB)

    Duck, Francis A

    2003-01-21

    Institute of Physics and Engineering in Medicine York: IPEM (2001) 67 pp, 20.00 British Pounds, ISBN: 0-904181-98-7. This 67-page soft-cover report has been prepared by an expert group within the Institute of Physics and Engineering in Medicine (IPEM) to provide detailed guidance on the testing and calibration of ultrasound therapy devices. Physiotherapists have long used external energy sources to supplement massage and manipulation for musculo-skeletal therapy. Whilst, recently, there has been a general reduction in use of electrotherapy using radio-frequency radiation, microwaves and interferential devices, ultrasound therapy still remains central to physiotherapy practice. There is now robust evidence that, at least for some injuries, ultrasound accelerates the repair of injured tissue. This has been particularly well demonstrated for bone fracture repair. Managed therapy relies on well-calibrated radiation sources. Unfortunately, there has been less than adequate management of ultrasound output in the past. Several well-documented situations have occurred for which faulty ultrasound equipment has continued in clinical use, either generating no output at all, or, more seriously, operating at maximum power all the time. This report reminds those responsible for managing ultrasound equipment of the need for testing and calibration, and gives detailed advice on procedures for carrying this out. These details are contained in 12 annexes forming the majority of the text. Each annex presents a self-contained aspect of one aspect of testing or calibration, such as the measurement of acoustic power, or an example protocol for machine testing. Each is sufficiently detailed to allow novice technical staff to follow the recommended procedure, or to allow a department to plan to introduce ultrasound field calibration into its practice. Other annexes contain useful additional material, not included in the earlier IPSM Report 58. A procedure for the measurement of effective

  18. Irradiation Effects Test Series: Test IE-2. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Allison, C. M.; Croucher, D. W.; Ploger, S. A.; Mehner, A. S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m/sup 2/. After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m/sup 2/, the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m/sup 2/ caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations.

  19. Machine testning

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    This document is used in connection with a laboratory exercise of 3 hours duration as a part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The exercise includes a series of tests carried out by the student on a conventional and a numerically controled lathe, respectively. This document...

  20. PROJECT, MANUFACTURING AND QUALIFICATION OF MACHINE TO ROTARY BENDING OF NITI SUPERELASTIC WIRES IN FATIGUE TESTS

    Directory of Open Access Journals (Sweden)

    William Marcos Muniz Menezes

    2014-03-01

    Full Text Available In this work it was developed a rotating bending apparatus for fatigue tests of superelastic NiTi wires, and other materials with high elasticity. It was evaluated the performance, robustness, operability, and reliability through testing of 1 mm thick stainless steel wires. This device is mounted on a steel frame and features semiautomatic rotation speed control, time and testing bath temperature for sample immersion. The equipment qualification tests were performed controlling the following parameters: deformation of the wire, power level and ambient temperature. The results indicated lower discrepancies for the following parameters evaluated: number of cycles in fatigue life, rotation speed, the bath temperature and arc angle of rupture. Besides the reliability, the robustness and operability of the equipment also meet the purpose of the research as evidenced by the small number of failures in the qualification tests and calibration.

  1. A testing method for the machine details state by means of the speckle image parameters analysis

    Science.gov (United States)

    Malov, A. N.; Pavlov, P. V.; Neupokoeva, A. V.

    2016-08-01

    Non destructive testing method, allowing to define a residual resource of power details of mechanical engineering designs under the analysis of registered speckle-image parameters, it is discussed. The "chessboard" algorithm based on calculation of correlation between the given speckle-image and the a chessboard image is considered. Experimental research results of an offered non destructive testing method are presented. It is established, that to increase in quantity of a power detail tests cycles there is an increase in roughness parameters that conducts to reduction of correlation factor between reference and to resultants the image at the given stage of test. Knowing of correlation factor change dynamics, it is possible to define a residual resource of power details while in exploitation.

  2. Perspex machine: VII. The universal perspex machine

    Science.gov (United States)

    Anderson, James A. D. W.

    2006-01-01

    The perspex machine arose from the unification of projective geometry with the Turing machine. It uses a total arithmetic, called transreal arithmetic, that contains real arithmetic and allows division by zero. Transreal arithmetic is redefined here. The new arithmetic has both a positive and a negative infinity which lie at the extremes of the number line, and a number nullity that lies off the number line. We prove that nullity, 0/0, is a number. Hence a number may have one of four signs: negative, zero, positive, or nullity. It is, therefore, impossible to encode the sign of a number in one bit, as floating-point arithmetic attempts to do, resulting in the difficulty of having both positive and negative zeros and NaNs. Transrational arithmetic is consistent with Cantor arithmetic. In an extension to real arithmetic, the product of zero, an infinity, or nullity with its reciprocal is nullity, not unity. This avoids the usual contradictions that follow from allowing division by zero. Transreal arithmetic has a fixed algebraic structure and does not admit options as IEEE, floating-point arithmetic does. Most significantly, nullity has a simple semantics that is related to zero. Zero means "no value" and nullity means "no information." We argue that nullity is as useful to a manufactured computer as zero is to a human computer. The perspex machine is intended to offer one solution to the mind-body problem by showing how the computable aspects of mind and, perhaps, the whole of mind relates to the geometrical aspects of body and, perhaps, the whole of body. We review some of Turing's writings and show that he held the view that his machine has spatial properties. In particular, that it has the property of being a 7D lattice of compact spaces. Thus, we read Turing as believing that his machine relates computation to geometrical bodies. We simplify the perspex machine by substituting an augmented Euclidean geometry for projective geometry. This leads to a general

  3. a Development of Multi Purpose Testing Machine for Friction, Wear and Rolling Contact Fatigue

    Science.gov (United States)

    Choi, Gab-Su; Pyun, Young-Sik; Kim, Jun-Hyoung; Kim, Hak-Doo; Tominaga, Yasutoshi; Darisuren, Shirmendagwa

    In this paper, the newly developed tribometer was introduced. Ball-on-disk, pin-on-disk, small-sized journal and thrust bearings tests on friction and wear were carried out using a newly developed tribometer which is built up according to the ASTM G99. Those friction and wear test results were compared with the friction results which were approved by Korean (KOLAS) and CSM Instruments. The comparison revealed that friction characteristics and trends of three different tribometers were similar to each other. The objective of this paper is to demonstrate the capability of the newly developed tribometer. As a result, the newly developed tribometer is capable of performing friction tests using pin-on-disk, disk-on-disk, journal and thrust bearings configurations.

  4. Are the Federal Reserve's Stress Test Results Predictable?

    OpenAIRE

    Paul Glasserman; Gowtham Tangirala

    2015-01-01

    Regulatory stress tests have become a key tool for setting bank capital levels. Publicly disclosed results for four rounds of stress tests suggest that as the stress testing process has evolved, its outcomes have become more predictable and therefore arguably less informative. In particular, projected stress losses in the 2013 and 2014 stress tests are nearly perfectly correlated for bank holding companies that participated in both rounds. We also compare projected losses across different sce...

  5. Hawaiian Electric Advanced Inverter Test Plan - Result Summary

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Nelson, Austin; Prabakar, Kumaraguru; Nagarajan, Adarsh

    2016-10-14

    This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

  6. THE RESULTS OF THE STUDY BOILING POINT OUT OZONE-SAFE REFRIGERANT R410A IN THE EVAPORATORS OF REFRIGERATING MACHINES

    Directory of Open Access Journals (Sweden)

    V. G. Bukin

    2012-01-01

    Full Text Available The results of experimental research boiling heat transfer of ozone-friendly R410A refrigerant in evaporators machines and the possibility of its use in place of the prohibited refrigerant R22.

  7. Exposure assessment method for products containing carbon nanotubes inside a test chamber with a Taber abrasion machine

    Science.gov (United States)

    Matsui, Yasuto; Nagaya, Taiki; Nobuyuki, Kato; Ishibashi, Tomonori; Yoneda, Minoru

    2017-06-01

    Polymer/carbon nanotube (CNT) composites exhibit distinguished properties, but more quantitative risk assessments on CNTs are necessary as research and development advances. One method to assess the exact risk is to evaluate the characteristics of nanoparticles generated from CNT composites during sanding or Taber abrasion tests. Some researchers have applied loads to CNT composites using Taber machines and analysed the particles using aerosol-measuring instruments and electron microscopes. However, employing aerosol-measuring instruments is challenging due to the small amount of generated particles. Additionally, the presence of abundant background nanoparticles in testing environments creates issues in quantitative measurements. Our research strives to develop an examination method to measure even very small amounts of nanoparticles generated by Taber abrasion. In this study, a Taber abrasion machine is miniaturised so that it fits inside a small chamber. A high-efficiency particulate air filter is attached to the chamber to eliminate background nanoparticles. Then CNT composites are abraded with the miniaturised Taber abrasion machine inside the chamber and the generated particles are analysed.

  8. Characterization of a medical X-ray machine for testing the response of electronic dosimeters in pulsed radiation fields

    Science.gov (United States)

    Guimarães, Margarete C.; Da Silva, Teógenes A.

    2014-11-01

    Electronic personal dosimeters (EPD) based on solid state detectors have been used for personnel monitoring for radiation protection purpose; their use has been extended to practices with pulsed radiation beams although their performance is not well known. Deficiencies in the EPD response in pulsed radiation fields have been reported; they were not detected before since type tests and calibrations of EPDs were established in terms of continuous X and gamma reference radiations. An ISO working group was formed to elaborate a standard for test conditions and performance requirements of EPDs in pulsed beams; the PTB/Germany implemented a special X-ray facility for generating the reference pulsed radiation beams. In this work, an 800 Plus VMI medical X-ray machine of the Dosimeter Calibration Laboratory of CDTN/CNEN was characterized to verify its feasibility to perform EPD tests. Characterization of the x-ray beam was done in terms of practical peak voltage, half-value layer, mean energy and air kerma rate. Reference dosimeters used for air kerma measurements were verified as far their metrological coherence and a procedure for testing EDPs was established. Electronic personal dosimeters (EPD) have been used for personnel monitoring. EPD use has been extended to pulsed radiation beams. Deficiencies in the EPD response in pulsed beams have been reported. The feasibility of using a medical X-ray machine to perform EPD tests was studied. Reference dosimeters were verified and EPD testing procedure was established.

  9. Technology Optimized Test on the Cutter of Agricultural Machine by Flame Spraying and Remelting NiWC Alloy

    Institute of Scientific and Technical Information of China (English)

    HAO Jian-jun; LI Hui-ping; MA Yue-jin; SHEN Yu-zeng

    2004-01-01

    In order to solve the problemof the machine for chopping and returning stubble into soil high-priced and short-lifetime, wear-resistance coating was made on the substrate of 45# steel by flame spraying and remelting NiWC alloy. By means of orthogonal test and multiple factors variance analysis, how the test factors influence the wear-resistance was studied.The technology parameters of flame spraying and remelting NiWC alloy were optimized as follows: coating matching,65% Ni60+ 35% WC; preheat temperature ,450 ℃; acetylene flow, 1000 L/h; spraying distance ,40 mm.

  10. Online Dynamic Parameter Estimation of Synchronous Machines

    Science.gov (United States)

    West, Michael R.

    Traditionally, synchronous machine parameters are determined through an offline characterization procedure. The IEEE 115 standard suggests a variety of mechanical and electrical tests to capture the fundamental characteristics and behaviors of a given machine. These characteristics and behaviors can be used to develop and understand machine models that accurately reflect the machine's performance. To perform such tests, the machine is required to be removed from service. Characterizing a machine offline can result in economic losses due to down time, labor expenses, etc. Such losses may be mitigated by implementing online characterization procedures. Historically, different approaches have been taken to develop methods of calculating a machine's electrical characteristics, without removing the machine from service. Using a machine's input and response data combined with a numerical algorithm, a machine's characteristics can be determined. This thesis explores such characterization methods and strives to compare the IEEE 115 standard for offline characterization with the least squares approximation iterative approach implemented on a 20 h.p. synchronous machine. This least squares estimation method of online parameter estimation shows encouraging results for steady-state parameters, in comparison with steady-state parameters obtained through the IEEE 115 standard.

  11. Results of Detailed Hydrologic Characterization Tests - Fiscal Year 1999

    Energy Technology Data Exchange (ETDEWEB)

    Spane, Frank A.; Thorne, Paul D.; Newcomer, Darrell R.

    2001-01-19

    This report provides the results of detailed hydrologic characterization tests conducted within newly constructed Hanford Site wells during FY 1999. Detailed characterization tests performed during FY 1999 included: groundwater flow characterization, barometric response evaluation, slug tests, single-well tracer tests, constant-rate pumping tests, and in-well vertical flow tests. Hydraulic property estimates obtained from the detailed hydrologic tests include: transmissivity, hydraulic conductivity, specific yield, effective porosity, in-well lateral flow velocity, aquifer flow velocity, vertical distribution of hydraulic conductivity (within the well-screen section) and in-well vertical flow velocity. In addition, local groundwater flow characteristics (i.e., hydraulic gradient and flow direction) were determined for four sites where detailed well testing was performed.

  12. Environmental testing results over a tracker drive train

    Science.gov (United States)

    Martínez, María; Calvo-Parra, Gustavo; Gil, Eduardo; de la Rubia, Oscar; Hillebrand, Mario; Rubio, Francisca; Aipperspach, Wolfgang; Gombert, Andreas

    2014-09-01

    Environmental testing following the draft of the IEC62817 standard has been carried out at ISFOC using a Soitec Solar tracker drive. The objective of this work is twofold; first to assure that the tracker design can perform under varying conditions and survive under extreme conditions and secondly to test the viability and usefulness of the tests described in the standard. After some changes in the device under test (specifically, gear-box oil) the drive system produced satisfactory results, assuring its performance under operational temperatures. Therefore, this work has demonstrated that the tests described in the standard are useful for detecting early failures.

  13. Test results judgment method based on BIT faults

    Institute of Scientific and Technical Information of China (English)

    Wang Gang; Qiu Jing; Liu Guanjun; Lyu Kehong

    2015-01-01

    Built-in-test (BIT) is responsible for equipment fault detection, so the test data correct-ness directly influences diagnosis results. Equipment suffers all kinds of environment stresses, such as temperature, vibration, and electromagnetic stress. As embedded testing facility, BIT also suffers from these stresses and the interferences/faults are caused, so that the test course is influenced, resulting in incredible results. Therefore it is necessary to monitor test data and judge test failures. Stress monitor and BIT self-diagnosis would redound to BIT reliability, but the existing anti-jamming researches are mainly safeguard design and signal process. This paper focuses on test results monitor and BIT equipment (BITE) failure judge, and a series of improved approaches is proposed. Firstly the stress influences on components are illustrated and the effects on the diagnosis results are summarized. Secondly a composite BIT program is proposed with information integra-tion, and a stress monitor program is given. Thirdly, based on the detailed analysis of system faults and forms of BIT results, the test sequence control method is proposed. It assists BITE failure judge and reduces error probability. Finally the validation cases prove that these approaches enhance credibility.

  14. Results of recent KROTOS FCI tests. Alumina vs. corium melts

    Energy Technology Data Exchange (ETDEWEB)

    Huhtiniemi, I.; Magallon, D.; Hohmann, H. [Commission of the European Communities, Ispra (Italy). Joint Research Center

    1998-01-01

    Recent results from KROTOS fuel-coolant interaction experiments are discussed. Five tests with alumina were performed under highly subcooled conditions, all of these tests resulted in spontaneous steam explosions. Additionally, four tests were performed at low subcooling to confirm, on one hand, the suppression of spontaneous steam explosions under such conditions and, on the other hand, that such a system is still triggerable using an external initiator. The other test parameters in these alumina tests included the melt superheat and the initial pressure. All the tests in the investigated superheat range (150 K - 750 K) produced a steam explosion and no evidence of the explosion suppression by the elevated initial pressure (in the limited range of 0.1 - 0.375 MPa) was observed in the alumina tests. The corium test series include a test with 3 kg of melt under both subcooled and near saturated conditions at ambient pressure. Two additional tests were performed with subcooled water; one test was performed at an elevated pressure of 0.2 MPa with 2.4 kg of melt and another test with 5.1 kg of melt at ambient pressure. None of these tests with corium produced a propagating energetic steam explosion. However, propagating low energy (about twice the energy of the trigger pulse) events were observed. All corium tests produced significantly higher water level swells during the mixing phase than the corresponding alumina tests. Present experimental evidence suggests that the water depletion in the mixing zone suppresses energetic steam explosions with corium melts at ambient pressure and in the present pour geometry. Processes that could produce such a difference in void generation are discussed. (author)

  15. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  16. Mechanical properties testing and results for thermal barrier coatings

    Energy Technology Data Exchange (ETDEWEB)

    Cruse, T.A.; Johnsen, B.P.; Nagy, A.

    1995-10-01

    The paper reports on several years of mechanical testing of thermal barrier coatings. The test results were generated to support the development of durability models for the coatings in heat engine applications. The test data that are reviewed include modulus, static strength, and fatigue strength data. The test methods and results are discussed, along with the significant difficulties inherent in mechanical testing of thermal barrier coating materials. The materials include 7 percent wt. and 8 percent wt. yttria, partially stabilized zirconia as well as a cermet material. Both low pressure plasma spray and electron-beam physical vapor deposited coatings were tested. The data indicate the basic trends in the mechanical properties of the coatings over a wide range of isothermal conditions. Some of the trends are correlated with material density.

  17. Mechanical properties testing and results for thermal barrier coatings

    Science.gov (United States)

    Cruse, Thomas A.; Johnsen, B. P.; Nagy, Andrew

    1995-01-01

    The paper reports on several years of mechanical testing of thermal barrier coatings. The test results were generated to support the development of durability models for the coatings in heat engine applications. The test data that are reviewed include modulus, static strength, and fatigue strength data. The test methods and results are discussed, along with the significant difficulties inherent in mechanical testing of thermal barrier coating materials. The materials include 7 percent wt. and 8 percent wt. yttria, partially stabilized zirconia as well as a cermet material. Both low pressure plasma spray and electron-beam physical vapor deposited coatings were tested. The data indicate the basic trends in the mechanical properties of the coatings over a wide range of isothermal conditions. Some of the trends are correlated with material density.

  18. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  19. New results from pulse tests in the CABRI reactor

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, F.; Papin, J.; Haessler, M. [Institut de Proterction et de Surete Nucleaire, Saint Paul Lez Durance (France)] [and others

    1996-03-01

    At the 21st and 22nd WRSM (1,2), the motivation and objectives of the French program on the behaviour of high burnup PWR fuel under RIA conditions in the CABRI test reactor has been presented. The major results of the three first tests of the test matrix were presented and in particular REP-Na1, which failed at an unexpected low level of fuel enthalpy, was exposed to the community of nuclear safety research. At this time, no final understanding was reached for the origin of the failure. This objective is reached now. Two further tests, REP-Na4 and 5, have been performed in 1995, they demonstrated a satisfactory and safe behaviour by resisting to the early phase of severe loading during the RIA pulse test. Further examination work and analytical testing is in progress and the next tests with MOX fuel are being prepared.

  20. Results of Edge Scatter Testing for a Starshade Mission

    Science.gov (United States)

    Smith, Daniel; Casement, L. Suzanne; Ellis, Scott; Stover, John; Warwick, Steve

    2017-01-01

    In the field of exoplanet detection and characterization, the use of a starshade, an external occulter in front of a telescope at large separations, has been identified as one of the highly promising methods to achieve the necessary high contrast imagery. Control of scattered sunlight from the edges of the starshade into the telescope has been identified as one of the key technology development areas in order to make the starshade feasible. Modeling of the scattered light has resulted in very different results so a campaign of experimentation with edge samples was undertaken to attempt to understand the discrepancies.Here, we present our results from the measurement of select samples of materials which would be suitable for manufacturing the starshade edge, and related models. We have focused on coating metallic samples for ease of fabrication: Titanium, Aluminum, and a Beryllium Copper alloy. Using standard machine shop methods, we fabricated samples which had sharp edges with radius of curvature (RoC) between 15 and 20 μm. We then had these samples coated by two suppliers to evaluate how well these coating types would conform to the edge and provide scatter suppression. The results of scatter measurements of these coated edge samples are presented. These scatter results have been incorporated into a new geometrical model in FRED which includes the details of the starshade mechanical model. This model predicts both the magnitude and distribution of the scattered sunlight in the image plane of a nominal telescope. We present these results, including a first effort at modeling the Solar System at 10 pc as seen by this mission architecture.

  1. Colorectal Tumour Microsatellite Instability Test Results: Perspectives from Patients

    Directory of Open Access Journals (Sweden)

    Lindor Noralane M

    2004-05-01

    Full Text Available Abstract Purpose To determine which individuals with colorectal cancer (CRC were interested in knowing the results of their tumour microsatellite instability (MSI and immunohistochemistry (IHC testing. We were also interested in the patients' reasons for choosing to learn their results and in the impact of those results on overall self-assessed quality of life. Patients and Methods CRCs from 414 individuals were assayed for MSI and IHC for DNA mismatch repair gene products (MLH1, MSH2, MSH6. Individuals were invited to learn their MSI/IHC results. They randomly received either brief or extended educational materials about the testing and a pretest survey to learn reasons for their interest and to assess their pretest quality of life. Results Of the 414 individuals, 307 (74% chose to learn their results. There was no significant difference in interest in knowing test results according to gender, age, educational level, or family history of colon cancer. The level of detail in the information piece received by the patients did not influence their desire to know their test results. Self-assessed quality of life was not altered by receiving results and was not correlated with the test outcome. Conclusions Individuals with colorectal cancer had a high level of interest in learning their individual MSI/IHC test results and did not seem deterred by the inherent complexity or ambiguity of this information. Regardless of test outcome, results did not significantly affect self-assessed quality of life. Further studies are needed to assess comprehension of results and behavioural changes resulting from the learning of MSI/IHC results.

  2. NOx results from two combustors tested on medium BTU coal gas

    Science.gov (United States)

    Sherlock, T. P.; Carl, D. E.; Vermes, G.; Schwab, J.; Notardonato, J. J.

    1982-01-01

    The results of tests of two combustor configurations using coal gas from a 25 ton/day fluidized bed coal gasifier are reported. The trials were run with a ceramic-lined, staged rich/lean burner and an integral, all metal multiannular swirl burner (MASB) using a range of temperatures and pressures representative of industrial turbine inlet conditions. A lean mixture was examined at 104, 197, and 254 Btu/Scf, yielding NO(x) emissions of 5, 20, and 70 ppmv, respectively. The MASB was employed only with a gas rated at 220-270 Btu/Scf, producing 80 ppmv NO(x) at rated engine conditions. The results are concluded to be transferrable to current machines. Further tests on the effects of gas composition, the scaling of combustors to utility size, and the development of improved wall cooling techniques and variable geometry are indicated.

  3. Sims Prototype System 2 Test Results - Engineering Analysis

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-01-01

    This report describes the testing, the problems encountered, and the results and conclusions obtained from tests performed on the IBM Prototype system 2, solar hot water system, at the Marshall space flight Center Solar Test Facility. System 2 is a liquid, non-draining solar energy system for supplying domestic hot water to singe residences. The system consists of collectors, storage tank, heat exchanger, pumps and associated plumbing and controls.

  4. Design and Test of a Collecting Machine for the Plastic Film Residue%一种残膜检拾机的设计和试验

    Institute of Scientific and Technical Information of China (English)

    闫志鹏

    2015-01-01

    针对残膜对土地的带来的污染,人工检拾农田残留地膜劳动强度大、费时费力,检拾后的耕地需多次翻耕、松土等问题,设计了一种一次能完成捡膜、集膜、清膜及松土整地等作业工序的残膜检拾机械,并对该检拾机械进行了检拾作业研究,实验,对推广小型简易残膜检拾机械有着重要意义。%Aiming at the pollution of plastic film residue, the working intensity of collecting plastic films by hand is great and time-consuming, and the land is then need to be plowed and loosed repeatedly, a collecting machine for the plastic film resi-due which can collect plastic film residue and loosen the soil once for all is designed in this paper. The collecting work of this machine is researched and tested;the results show that it has great significance to generalize the small and simple machine for collecting plastic film residue.

  5. Online cognition: factors facilitating reliable online neuropsychological test results.

    Science.gov (United States)

    Feenstra, Heleen E M; Vermeulen, Ivar E; Murre, Jaap M J; Schagen, Sanne B

    2017-01-01

    Online neuropsychological test batteries could allow for large-scale cognitive data collection in clinical studies. However, the few online neuropsychological test batteries that are currently available often still require supervision or lack proper psychometric evaluation. In this paper, we have outlined prerequisites for proper development and use of online neuropsychological tests, with the focus on reliable measurement of cognitive function in an unmonitored setting. First, we identified several technical, contextual, and psychological factors that should be taken into account in order to facilitate reliable test results of online tests in the unmonitored setting. Second, we outlined a methodology of quality assurance needed in order to obtain reliable cognitive data in the long run. Based on factors that distinguish the online unmonitored test setting from the traditional face-to-face setting, we provide a set of basic requirements and suggestions for optimal development and use of unmonitored online neuropsychological tests, including suggestions on acquiring reliability, validity, and norm scores. When properly addressing factors that could hamper reliable test results during development and use, online neuropsychological tests could aid large-scale data collection for clinical studies in the future. Investment in both proper development of online neuropsychological test platforms and the performance of accompanying psychometric studies is currently required.

  6. Leak tightness tests on actively cooled plasma facing components: Lessons learned from Tore Supra experience and perspectives for the new fusion machines

    Energy Technology Data Exchange (ETDEWEB)

    Chantant, M., E-mail: michel.chantant@cea.fr; Lambert, R.; Gargiulo, L.; Hatchressian, J.-C.; Guilhem, D.; Samaille, F.; Soler, B.

    2015-10-15

    CrZr structures (toroidal pumped limiter (TPL) composed of 12 sectors of 48 fingers) but also on all metallic ones (ICRH antennas and LHH launchers, vacuum vessel protection walls ∼60 m{sup 2}). During the tests, some leaks were found and the components had to be repaired. The analysis of the results database allows defining guidelines to optimize the presently used procedure for the new ACPFCs generation which will be set-up in WEST or ITER (tungsten (W) elements, high mass components). This paper presents the experience of the Tore Supra teams in the implementation of ACPFC with regard to the tightness issues including the tests procedures which were developed and used since 1990. The prospects for the new generation actively cooled machines are also discussed.

  7. Machine vision process monitoring on a poultry processing kill line: results from an implementation

    Science.gov (United States)

    Usher, Colin; Britton, Dougl; Daley, Wayne; Stewart, John

    2005-11-01

    width information of the entire chicken and different parts such as the breast, the legs, the wings, and the neck. The system also records average color and miss- hung birds, which can cause problems in further processing. Other relevant production information is also recorded including truck arrival and offloading times, catching crew and flock serviceman data, the grower, the breed of chicken, and the number of dead-on- arrival (DOA) birds per truck. Several interesting observations from the Georgia Tech vision system, which has been installed in a poultry processing plant for several years, are presented. Trend analysis has been performed on the performance of the catching crews and flock serviceman, and the results of the processed chicken as they relate to the bird dimensions and equipment settings in the plant. The results have allowed researchers and plant personnel to identify potential areas for improvement in the processing operation, which should result in improved efficiency and yield.

  8. What Do the Results of Genetic Tests Mean?

    Science.gov (United States)

    ... healthcare professionals consider a person’s medical history, family history, and the type of genetic test that was done. A positive test result means that the laboratory found a change in a particular gene, chromosome, or protein of interest. Depending on the purpose of the ...

  9. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  10. 49 CFR 199.229 - Reporting of alcohol testing results.

    Science.gov (United States)

    2010-10-01

    ... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... 49 CFR part 40 (at § 40.25 and appendix H to part 40), not later than March 15 of each year for the...

  11. Test results for SEU and SEL immune memory circuits

    Science.gov (United States)

    Wiseman, D.; Canaris, J.; Whitaker, S.; Gambles, J.; Arave, K.; Arave, L.

    1993-01-01

    Test results for three SEU logic/circuit hardened CMOS memory circuits verify upset and latch-up immunity for two configurations to be in excess of 120 MeV cm(exp 2)/mg using a commercial, non-radiation hardened CMOS process. Test chips from three separate fabrication runs in two different process were evaluated.

  12. Development and Results of a First Generation Least Expensive Approach to Fission: Module Tests and Results

    Science.gov (United States)

    Houts, Mike; Godfroy, Tom; Pederson, Kevin; Sena, J. Tom; VanDyke, Melissa; Dickens, Ricky; Reid, Bob J.; Martin, Jim

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on the Module Unfueled Thermal-hydraulic Test (MUTT) article has been performed at the Marshall Space Flight Center. This paper discusses the results of these experiments and identifies future tests to be performed.

  13. Preliminary results of steel containment vessel model test

    Energy Technology Data Exchange (ETDEWEB)

    Luk, V.K.; Hessheimer, M.F. [Sandia National Labs., Albuquerque, NM (United States); Matsumoto, T.; Komine, K.; Arai, S. [Nuclear Power Engineering Corp., Tokyo (Japan); Costello, J.F. [Nuclear Regulatory Commission, Washington, DC (United States)

    1998-04-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11--12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented.

  14. Results of Lunar Rover Drivetrain TRL-6 Environmental Testing

    Science.gov (United States)

    Visscher, P.; Edmundson, P.; Ghafoor, N.; Jones, H.; Kleinhenz, J.; Picard, M.

    2016-11-01

    Latest results of work performed by Ontario Drive and Gear Ltd., Canadensys Aerospace Corporation, and partners on Canadian lunar rover development activities for the Canadian Space Agency, including "dirty" thermal vacuum testing of drivetrain unit.

  15. Calibration of Results of Water Meter Test Facility

    OpenAIRE

    Andrius Bončkus; Gediminas Gediminas

    2011-01-01

    The results of water meter test facility calibration are presented. More than 30 test facilities are used in Lithuania nowadays. All of them are certificated for water meter of class 2 verification. The results of inter-laboratory comparison of multi-jet water meter calibration at flow rate Q = 5 m3/h are presented. Lithuanian Energy Institute was appointed as reference laboratory for the comparison. Twelve water meter verification and calibration laboratories from Lithuania participated in t...

  16. Influence of diet on the results of laboratory tests

    Directory of Open Access Journals (Sweden)

    Kinga Lis

    2013-12-01

    Full Text Available Blood and urine laboratory tests are necessary to diagnose the state of the patient. These tests are also helpful in the assessment of diet and nutritional status of the organism. It is recommended that both blood and urine for laboratory tests be collected in the morning, from fasting patients after an overnight rest. These conditions are defined as the standard conditions for collection of material for laboratory testing. Before testing, patients should follow their natural diet and avoid physical exertion, night work, long-distance travel, as well as consumption of alcohol and drugs. They should also reduce the consumption of synthetic vitamins and herbal remedies and other dietary supplements. Medications should be limited to those that are absolutely necessary. All of these factors can affect the results of laboratory tests.

  17. The clinical utility of a positive antinuclear antibody test result.

    Science.gov (United States)

    Abeles, Aryeh M; Abeles, Micha

    2013-04-01

    This retrospective study investigated the clinical utility of a positive antinuclear antibody (ANA) test performed outside of the rheumatology setting. Prior studies have investigated the frequency of ANA positivity within the general population. The purpose of this investigation was to evaluate the clinical utility of a positive ANA test result in a real-world setting by reviewing the final diagnoses of patients who were referred to a tertiary rheumatology clinic for evaluation of a positive ANA test result. We reviewed the records of patients presenting to the authors between July 2007 and July 2009. Patients were included in the evaluation if they were referred for a positive ANA test result. All relevant descriptive and laboratory data were collated, as were the initial reasons for ordering ANA testing and the ultimate diagnoses reached. Positive predictive values for a "positive ANA test result" were calculated for all antinuclear antibody-associated rheumatic diseases and for lupus specifically. A total of 232 patients were referred for a positive ANA test result. The positive predictive value of a positive ANA test result in this cohort was 2.1% for lupus and 9.1% for any antinuclear antibody-associated rheumatic disease. No antinuclear antibody-associated rheumatic disease was identified in patients with an ANAresult had no evidence for an ANA-associated rheumatic disease. The poor predictive value of a positive ANA in this cohort was largely attributable to unnecessary testing in patients with low pretest probabilities for ANA-associated rheumatic disease. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Congenital syphilis in neonates with nonreactive nontreponemal test results.

    Science.gov (United States)

    Wozniak, P S; Cantey, J B; Zeray, F; Leos, N K; Sheffield, J S; Wendel, G D; Sánchez, P J

    2017-07-06

    Infants whose mothers had syphilis during pregnancy were studied to determine how often exposed newborns with normal physical examinations and nonreactive nontreponemal serologic tests had abnormal laboratory or radiographic studies. Retrospective analysis of prospectively collected data from infants born to mothers with syphilis and had a normal examination and a nonreactive nontreponemal test. Some infants had IgM immunoblotting, PCR testing or rabbit infectivity testing (RIT) performed. From 1984 to 2002, 115 infants had a nonreactive serum Venereal Disease Research Laboratory (VDRL)/rapid plasma reagin (RPR) test and a normal physical examination at birth. Among 87 infants born to mothers who had untreated syphilis, 4 had a positive serum IgM immunoblot or PCR test, but none had spirochetes recovered by RIT. Two infants had anemia, one had an elevated serum alanine aminotransferase concentration and one with Down's syndrome had direct hyperbilirubinemia. Among 14 infants born to mothers treated laboratory or radiographic tests, although 1 of 11 had a reactive serum IgM immunoblot. Among 14 infants born to mothers treated ⩾4 weeks before delivery, none had abnormal laboratory or radiographic tests. Newborns with normal physical examination and nonreactive nontreponemal test results are unlikely to have abnormalities detected on conventional laboratory and radiographic testing.Journal of Perinatology advance online publication, 6 July 2017; doi:10.1038/jp.2017.103.

  19. Results from the Astronomy Diagnostic Test National Project

    Science.gov (United States)

    Deming, G. L.

    2001-12-01

    During 2000 and 2001, the validity and reliability of the Astronomy Diagnostic Test Version 2.0 (ADT 2.0) were formally investigated through the Astronomy Diagnostic Test National Project. The ADT 2.0 was administered as a pre-test to 5346 students and as a post-test to 3842 students. Student test results were collected from 97 classes that ranged in size from 4 to 320 students with 30 states represented. The 68 professors participating in the ADT National Project taught classes at universities (54%), 4-year colleges (27%), and 2-year colleges (19%). The database was analyzed for reliability at the Ontario Institute for Studies in Education. A pre-test value for Cronbach's alpha of 0.65 and post-test value of 0.76 demonstrate an acceptable degree of internal consistency. The average score for the 44 participating professors who completed the ADT as experts was 98%. Face and content validity were established by combining results from the experts with feedback from 60 student interviews. Student results from the National Project yielded an average score of 32.4% for the pre-test and 47.3% for the post-test. There is a gender discrepancy in favor of males that persists in both the pre-test (11% points) and the post-test (12% points) scores. The variations across geographic distribution and institution types were not significant. In addition to the 21 content items, the ADT 2.0 has 12 student background questions enabling instructors to have a better understanding of who takes introductory astronomy. This research was supported by the National Science Foundation through grants REC-0089239 (GD) and DGE-9714489 (BH).

  20. A report on the psychological test results of battering parents.

    Science.gov (United States)

    Hyman, C A

    1977-09-01

    The short form of the Wechsler Adult Intelligence Scale and Cattell's 16PF test have been given to patients attending the National Advisory Centre on the Battered Child (NSPCC) and in the case of the personality questionnaire the results compared to non-battering control adults' scores. The intelligence levels of battering parents conform to normal expectation although there is a non-significant trend to marginally lower than normal results especially in verbal tests. The 16PF test reveals immature impetuosity on the part of the mothers as a main finding and introversion in the fathers. The relevance of these findings to battering is discussed.

  1. A systemic approach to testing the tribological properties of selected materials of agricultural machines

    Directory of Open Access Journals (Sweden)

    Marian Kučera

    2014-03-01

    Full Text Available The contribution brings the evaluation of selected materials regarding wear resistance under conditions of two experiments. The following materials had been chosen for these experiments: steel E295, steel C 45 after heat treatment, steel C 45 after quenching and steel 16MnCr5 after carburizing and quenching. The experiment was performed on a test device belonging to the category of “pin – disk“ test devices. The resistance of selected materials was evaluated regarding energy consumption, and it was compared to sizes of weight loss. It was observed that the material C 45 after heat treatment reached the highest values of wear resistance in conditions of adhesive wear without lubrication. The material 16MnCr5 indicated the best results in conditions of abrasive wear.

  2. Assessment of Galileo modal test results for mathematical model verification

    Science.gov (United States)

    Trubert, M.

    1984-01-01

    The modal test program for the Galileo Spacecraft was completed at the Jet Propulsion Laboratory in the summer of 1983. The multiple sine dwell method was used for the baseline test. The Galileo Spacecraft is a rather complex 2433 kg structure made of a central core on which seven major appendages representing 30 percent of the total mass are attached, resulting in a high modal density structure. The test revealed a strong nonlinearity in several major modes. This nonlinearity discovered in the course of the test necessitated running additional tests at the unusually high response levels of up to about 21 g. The high levels of response were required to obtain a model verification valid at the level of loads for which the spacecraft was designed. Because of the high modal density and the nonlinearity, correlation between the dynamic mathematical model and the test results becomes a difficult task. Significant changes in the pre-test analytical model are necessary to establish confidence in the upgraded analytical model used for the final load verification. This verification, using a test verified model, is required by NASA to fly the Galileo Spacecraft on the Shuttle/Centaur launch vehicle in 1986.

  3. Uprated OMS Engine Status-Sea Level Testing Results

    Science.gov (United States)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  4. Determination of Induction Machine Parameters by Simulation

    OpenAIRE

    Dr. E.A. Anazia; Engr. Samson Ugochukwu; Dr. J. C. Onuegbu; Engr. Onyedikachi S.N

    2016-01-01

    A 38.1 Watt fractional horse power induction laboratory test motor model was created using MotorSolve 5.2; an electrical machine design application. Initial machine parameters such as voltage, speed, and main dimensions were selected and fed into the application and simulations ran. The simulated results were presented and analyzed. Unlike other induction machine parameter identification process, this method is simple, flexible and accurate since it does not involve rigorous mathe...

  5. Measurement of ability emotional intelligence: results for two new tests.

    Science.gov (United States)

    Austin, Elizabeth J

    2010-08-01

    Emotional intelligence (EI) has attracted considerable interest amongst both individual differences researchers and those in other areas of psychology who are interested in how EI relates to criteria such as well-being and career success. Both trait (self-report) and ability EI measures have been developed; the focus of this paper is on ability EI. The associations of two new ability EI tests with psychometric intelligence, emotion perception, and the Mayer-Salovey-Caruso EI test (MSCEIT) were examined. The new EI tests were the Situational Test of Emotion Management (STEM) and the Situational Test of Emotional Understanding (STEU). Only the STEU and the MSCEIT Understanding Emotions branch were significantly correlated with psychometric intelligence, suggesting that only understanding emotions can be regarded as a candidate new intelligence component. These understanding emotions tests were also positively correlated with emotion perception tests, and STEM and STEU scores were positively correlated with MSCEIT total score and most branch scores. Neither the STEM nor the STEU were significantly correlated with trait EI tests, confirming the distinctness of trait and ability EI. Taking the present results as a starting-point, approaches to the development of new ability EI tests and models of EI are suggested.

  6. Test results for the Oasis 3C high performance water-pumping windmill

    Energy Technology Data Exchange (ETDEWEB)

    Eggleston, D.M. [DME Engineering, Midland, TX (United States)

    1997-12-31

    The WINDTech International, L.L.C. Oasis 3C, a 3 m diameter, high-performance water-pumping windmill, was tested at the DME Engineering Wind Test Site just south of Midland, Texas from August through December, 1996. This machine utilizes a 3:1 gearbox with rotating counterweights, similar to a conventional oilfield pumping unit, driven by a multibladed rotor. The rotating counterweight system balances most of the pumping loads and reduces gear loads and starting torque by a factor of at least two and often by a factor of four or more. The torque reduction substantially extends gear and bearing life, and reduces wind speeds required for starting by 30 to 50% or more. The O3C was tested pumping from a quiescent fluid depth of 12.2 m (40 ft) from a 28.3 m (93 ft)-deep well, with additional pumping depth simulated using a pressure regulator valve system. A 9.53 cm (3.75 in.) diameter Harbison-Fischer seal-less single-acting piston pump was used to eliminate pump seal friction as a variable, and standard O3C stroke lengths of 30.5 and 15.2 cm (12 and 6 inches) were used. The regulator spring was set to give a maximum stroke rate of 33 strokes per minute. The water pumped was returned to the well after flowing through a settling tank. The tests were performed in accordance with AWEA WECS testing standards. Instrumentation provided 16 channels of data to accurately measure machine performance, including starting wind speeds, flow rates, O3C azimuth, tail furl angle, wind direction tracking errors, RPM, sucker rod loads, and other variables. The most significant performance data is summarized herein. A mathematical model of machine performance was developed that fairly accurately predicts performance for each of three test conditions. The results verify that the O3C is capable of pumping water at wind speeds from 30% to more than 50% lower than comparable un-counterbalanced units.

  7. Testing Result Statistics-Based Rapid Testing Method for Safety-Critical System

    Institute of Scientific and Technical Information of China (English)

    Zhi-Yao Deng; Nan Sang

    2008-01-01

    Safety-critical system (SCS) has highly demand for dependability, which requires plenty of resource to ensure that the system under test (SUT) satisfies the dependability requirement. In this paper, a new SCS rapid testing method is proposed to improve SCS adaptive dependability testing. The result of each test execution is saved in calculation memory unit and evaluated as an algorithm model. Then the least quantity of scenario test case for next test execution will be calculated according to the promised SUT's confidence level. The feedback data are generated to weight controller as the guideline for the further testing. Finally, a compre- hensive experiment study demonstrates that this adaptive testing method can really work in practice. This rapid testing method, testing result statistics-based adaptive control, makes the SCS dependability testing much more effective.

  8. Changes over time in milk test results following pancreatectomy

    Institute of Scientific and Technical Information of China (English)

    Hideki Aoki; Masashi Utsumi; Kenta Sui; Nobuhiko Kanaya; Tomoyoshi Kunitomo; Hitoshi Takeuchi; Norihisa Takakura; Shigehiro Shiozaki; Hiroyoshi Matsukawa

    2016-01-01

    AIM: To investigate changes over time in, and effects of sealing technology on, milk test results following pancreatectomy. METHODS: From April 2008 to October 2013, 66 pancreatic resections were performed at the Iwakuni Clinical Center. The milk test has been routinely conducted at the institute whenever possible during pancreatectomy. The milk test comprises the following procedure: A nasogastric tube is inserted until the third portion of the duodenum, followed by injection of 100 mL of milk through the tube. If a chyle leak is present, the patient tests positive in this milk test based on the observation of a white milky discharge. Positive milk test rates, leakage sites, and chylous ascites incidence were examined. Liga Sure?(LS; Covidien, Dublin, Ireland), a vessel-sealing device, is routinely used in pancreatectomy. Positive milk test rates before and after use of LS, as well as drain discharge volume at the 2nd and 3rd postoperative days, were compared retrospectively. Finally, positive milk test rates and chylous ascites incidence were compared with the results of a previous report.RESULTS: Fifty-nine milk tests were conducted during pancreatectomy. The positive milk test rate for all pancreatectomy cases was 13.6%(8 of 59 cases). One case developed postoperative chylous ascites(2.1% among the pancreatoduedenectomy cases and 1.7% among all pancreatectomies). Positive rates by procedure were 12.8% for pancreatoduodenectomy and 22.2% for distal pancreatectomy. Positive rates by disease were 17.9% for pancreatic and 5.9% for biliary diseases. When comparing results from before and after use of LS, positive milk test rates in pancreatoduodenectomy were 13.0% before and 12.5% after, while those in distal pancreatectomy were 33.3% and 0%. Drainage volume tended to decrease when LS was used on the 3rd postoperative day(volumes were 424 ± 303 mL before LS and 285 ± 185 mL after, P = 0.056). Both chylous ascites incidence and positive milk test

  9. Cold vacuum drying proof of performance (first article testing) test results

    Energy Technology Data Exchange (ETDEWEB)

    MCCRACKEN, K.J.

    1999-06-23

    This report presents and details the test results of the first of a kind process referred to as Cold Vacuum Drying (CVD). The test results are compiled from several months of testing of the first process equipment skid and ancillary components to de-water and dry Multi-Canister Overpacks (MCO) filled with Spent Nuclear Fuel (SNF). The tests results provide design verifications, equipment validations, model validation data, and establish process parameters.

  10. RF Test Results from Cryomodule 1 at the Fermilab SRF Beam Test Facility

    CERN Document Server

    Harms, E; Chase, B; Cullerton, E; Hocker, A; Jensen, C; Joireman, P; Klebaner, A; Kubicki, T; Kucera, M; Legan, A; Leibfritz, J; Martinez, A; McGee, M; Nagaitsev, S; Nezhevenko, O; Nicklaus, D; Pfeffer, H; Pischalnikov, Y; Prieto, P; Reid, J; Schappert, W; Tupikov, V; Varghese, P; Branlard, J

    2012-01-01

    Powered operation of Cryomodule 1 (CM-1) at the Fermilab SRF Beam Test Facility began in late 2010. Since then a series of tests first on the eight individual cavities and then the full cryomodule have been performed. We report on the results of these tests and lessons learned which will have an impact on future module testing at Fermilab.

  11. Ultrasonic image restoration based on support vector machine for surfacing interface testing

    Institute of Scientific and Technical Information of China (English)

    Gao Shuangsheng; Gang Tie; Chi Dazhao

    2007-01-01

    In order to restore the degraded ultrasonic C-scan image for testing surfacing interface, a method based on support vector regression (SVR) network is proposed. By using the image of a simulating defect, the network is trained and a mapping relationship between the degraded and restored image is founded. The degraded C-scan image of Cu-Steel surfacing interface is processed by the trained network and improved image is obtained. The result shows that the method can effectively suppress the noise and deblur the defect edge in the image, and provide technique support for quality and reliability evaluation of the surfacing weld.

  12. Proposed Interventions to Decrease the Frequency of Missed Test Results

    Science.gov (United States)

    Wahls, Terry L.; Cram, Peter

    2009-01-01

    Numerous studies have identified that delays in diagnosis related to the mishandling of abnormal test results are an import contributor to diagnostic errors. Factors contributing to missed results included organizational factors, provider factors and patient-related factors. At the diagnosis error conference continuing medical education conference…

  13. TEG® and ROTEM® in trauma: similar test but different results?

    Directory of Open Access Journals (Sweden)

    Sankarankutty Ajith

    2012-08-01

    Full Text Available Abstract Introduction Transfusion in trauma is often empiric or based on traditional lab tests. Viscoelastic tests such as thromboelastography (TEG® and rotational thromboelastometry (ROTEM® have been proposed as superior to traditional lab tests. Due to the similarities between the two tests, general opinion seems to consider them equivalent with interchangeable interpretations. However, it is not clear whether the results can be similarly interpreted. This review evaluates the comparability between TEG and ROTEM and performs a descriptive review of the parameters utilized in each test in adult trauma patients. Methods PUBMED database was reviewed using the keywords “thromboelastography” and “compare”, between 2000 and 2011. Original studies directly comparing TEG® with ROTEM® in any area were retrieved. To verify the individual test parameter used in studies involving trauma patients, we further performed a review using the keywords “thromboelastography” and “trauma” in the PUBMED database. Results Only 4 studies directly compared TEG® with ROTEM®. One in liver transplantation found that transfusion practice could differ depending on the device in use. Another in cardiac surgery concluded that all measurements are not completely interchangeable. The third article using commercially available plasma detected clinically significant differences in the results from the two devices. The fourth one was a head-to-head comparison of the technical aspects. The 24 articles reporting the use of viscoelastic tests in trauma patients, presented considerable heterogeneity. Conclusion Both tests are potentially useful as means to rapidly diagnose coagulopathy, guide transfusion and determine outcome in trauma patients. Differences in the activators utilized in each device limit the direct comparability. Standardization and robust clinical trials comparing the two technologies are needed before these tests can be widely recommended for

  14. Tensile and fracture toughness test results of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Chaouadi, R.; Moons, F.; Puzzolante, J.L. [Centre d`Etude de l`Energie Nucleaire, Mol (Belgium)

    1998-01-01

    Tensile and fracture toughness test results of four Beryllium grades are reported here. The flow and fracture properties are investigated by using small size tensile and round compact tension specimens. Irradiation was performed at the BR2 material testing reactor which allows various temperature and irradiation conditions. The fast neutron fluence (>1 MeV) ranges between 0.65 and 2.45 10{sup 21} n/cm{sup 2}. In the meantime, un-irradiated specimens were aged at the irradiation temperatures to separate if any the effect of temperature from irradiation damage. Test results are analyzed and discussed, in particular in terms of the effects of material grade, test temperature, thermal ageing and neutron irradiation. (author)

  15. Steel Containment Vessel Model Test: Results and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Costello, J.F.; Hashimote, T.; Hessheimer, M.F.; Luk, V.K.

    1999-03-01

    A high pressure test of the steel containment vessel (SCV) model was conducted on December 11-12, 1996 at Sandia National Laboratories, Albuquerque, NM, USA. The test model is a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of an improved Mark II boiling water reactor (BWR) containment. A concentric steel contact structure (CS), installed over the SCV model and separated at a nominally uniform distance from it, provided a simplified representation of a reactor shield building in the actual plant. The SCV model and contact structure were instrumented with strain gages and displacement transducers to record the deformation behavior of the SCV model during the high pressure test. This paper summarizes the conduct and the results of the high pressure test and discusses the posttest metallurgical evaluation results on specimens removed from the SCV model.

  16. COMPARISON OF RESULTS OF THERMAL TESTS OF BALCONY DOORS

    Directory of Open Access Journals (Sweden)

    Golubev Stanislav Sergeevich

    2012-10-01

    Full Text Available Results of thermal tests of balcony doors are presented in the article. In the course of the research project, two types of doors were tested. The first type represents a PVC frame door (width 82 mm; it has a triple glazing (4K-16Ar-4-16Ar-K4; its blank part represents a polystyrene sandwich panel (width 40 mm. The second type represents a PVC frame door (width 82 mm, that has a triple glazing (4K-16Ar-4-16Ar-K4 and composite PVC panels. The testing procedure and processing results are described in the article. The test has demonstrated that the thermal resistance value of the balcony door of the first type exceeds the thermal resistance value of the balcony door of the second type.

  17. Predicting diabetes mellitus using SMOTE and ensemble machine learning approach: The Henry Ford ExercIse Testing (FIT) project.

    Science.gov (United States)

    Alghamdi, Manal; Al-Mallah, Mouaz; Keteyian, Steven; Brawner, Clinton; Ehrman, Jonathan; Sakr, Sherif

    2017-01-01

    Machine learning is becoming a popular and important approach in the field of medical research. In this study, we investigate the relative performance of various machine learning methods such as Decision Tree, Naïve Bayes, Logistic Regression, Logistic Model Tree and Random Forests for predicting incident diabetes using medical records of cardiorespiratory fitness. In addition, we apply different techniques to uncover potential predictors of diabetes. This FIT project study used data of 32,555 patients who are free of any known coronary artery disease or heart failure who underwent clinician-referred exercise treadmill stress testing at Henry Ford Health Systems between 1991 and 2009 and had a complete 5-year follow-up. At the completion of the fifth year, 5,099 of those patients have developed diabetes. The dataset contained 62 attributes classified into four categories: demographic characteristics, disease history, medication use history, and stress test vital signs. We developed an Ensembling-based predictive model using 13 attributes that were selected based on their clinical importance, Multiple Linear Regression, and Information Gain Ranking methods. The negative effect of the imbalance class of the constructed model was handled by Synthetic Minority Oversampling Technique (SMOTE). The overall performance of the predictive model classifier was improved by the Ensemble machine learning approach using the Vote method with three Decision Trees (Naïve Bayes Tree, Random Forest, and Logistic Model Tree) and achieved high accuracy of prediction (AUC = 0.92). The study shows the potential of ensembling and SMOTE approaches for predicting incident diabetes using cardiorespiratory fitness data.

  18. Wellbore inertial navigation system (WINS) software development and test results

    Energy Technology Data Exchange (ETDEWEB)

    Wardlaw, R. Jr.

    1982-09-01

    The structure and operation of the real-time software developed for the Wellbore Inertial Navigation System (WINS) application are described. The procedure and results of a field test held in a 7000-ft well in the Nevada Test Site are discussed. Calibration and instrumentation error compensation are outlined, as are design improvement areas requiring further test and development. Notes on Kalman filtering and complete program listings of the real-time software are included in the Appendices. Reference is made to a companion document which describes the downhole instrumentation package.

  19. Physical separations soil washing system cold test results

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.P.

    1993-07-28

    This test summary describes the objectives, methodology, and results of a physical separations soil-washing system setup and shakedown test using uncontaminated soil. The test is being conducted in preparation for a treatability test to be conducted in the North Pond of the 300-FF-1 Operable Unit. It will be used to assess the feasibility of using a physical separations process to reduce the volume of contaminated soils in the 300-FF-1 Operable Unit. The test is described in DOE-RL (1993). The setup test was conducted at an uncontrolled area located approximately 3.2 km northwest of the 300-FF-1 Operable Unit. The material processed was free of contamination. The physical separation equipment to be used in the test was transferred to the US Department of Energy (DOE) by the US Environmental Protection Agency (EPA) Risk Reduction Engineering Laboratory. On May 13, 1993, soil-washing equipment was moved to the cold test location. Design assistance and recommendation for operation was provided by the EPA.

  20. Wear Test Results of Candidate Materials for the OK-542 Towed Array Handling Machine Level Winder

    Science.gov (United States)

    1994-12-29

    while extremely resistant to corrosion , is very strong mechanically and is readily available in bar form from local suppliers. Figure 32...Stainless Steel, Inconel 625, Nickel-Aluminum-Bronze, and Titanium. The specialty materials: Inconel 625, Monel, Stainless and Stellite , were clad-welded...C71500 Cu-Ni Wheel/Clad Stainless ............................................ 14 13. Clad Stellite

  1. Thermal Analysis of Low Layer Density Multilayer Insulation Test Results

    Science.gov (United States)

    Johnson, Wesley L.

    2011-01-01

    Investigation of the thermal performance of low layer density multilayer insulations is important for designing long-duration space exploration missions involving the storage of cryogenic propellants. Theoretical calculations show an analytical optimal layer density, as widely reported in the literature. However, the appropriate test data by which to evaluate these calculations have been only recently obtained. As part of a recent research project, NASA procured several multilayer insulation test coupons for calorimeter testing. These coupons were configured to allow for the layer density to be varied from 0.5 to 2.6 layer/mm. The coupon testing was completed using the cylindrical Cryostat-l00 apparatus by the Cryogenics Test Laboratory at Kennedy Space Center. The results show the properties of the insulation as a function of layer density for multiple points. Overlaying these new results with data from the literature reveals a minimum layer density; however, the value is higher than predicted. Additionally, the data show that the transition region between high vacuum and no vacuum is dependent on the spacing of the reflective layers. Historically this spacing has not been taken into account as thermal performance was calculated as a function of pressure and temperature only; however the recent testing shows that the data is dependent on the Knudsen number which takes into account pressure, temperature, and layer spacing. These results aid in the understanding of the performance parameters of MLI and help to complete the body of literature on the topic.

  2. Virtual machines & volunteer computing: Experience from LHC@Home: Test4Theory project

    CERN Document Server

    Lombraña González, Daniel; Blomer, Jakob; Buncic, Predrag; Harutyunyan, Artem; Marquina, Miguel; Segal, Ben; Skands, Peter; Karneyeu, Anton

    2012-01-01

    Volunteer desktop grids are nowadays becoming more and more powerful thanks to improved high end components: multi-core CPUs, larger RAM memories and hard disks, better network connectivity and bandwidth, etc. As a result, desktop grid systems can run more complex experiments or simulations, but some problems remain: the heterogeneity of hardware architectures and software (library dependencies, code length, big repositories, etc.) make it very difficult for researchers and developers to deploy and maintain a software stack for all the available platforms. In this paper, the employment of virtualization is shown to be the key to solve these problems. It provides a homogeneous layer allowing researchers to focus their efforts on running their experiments. Inside virtual custom execution environments, researchers can control and deploy very complex experiments or simulations running on heterogeneous grids of high-end computers. The following work presents the latest results from CERN’s LHC@home Test4Theory p...

  3. PCB测试机的基本测试原理与方法%Basic Test Principle and Method of PCB testing Machine

    Institute of Scientific and Technical Information of China (English)

    熊霞

    2015-01-01

    文章首先介绍PCB测试机系统组成,根据PCB测试机的基本原理即欧姆定理,采用先自检,再自学习,最后针对不同的检测要求,采用不同的测试方法,有两点间导通测试,两点间绝缘测试,及多点绝缘测试。测出被测点间是导通或者绝缘。%This paper first introduced the configuration of PCB testing machine system, according to the basic principle of PCB testing machine,namely,the Ohm theorem, conduct the conduction testing and insulation testing be-tween 2 points through self-inspection, self-learning, finally adopting different methods according to different detection requirements and find out whether it is conducting or insulating between the 2 points.

  4. Patch Test Results in Patients with Allergic Contact Dermatitis / Mucositis

    Directory of Open Access Journals (Sweden)

    Özlem Su

    2008-05-01

    Full Text Available Background and Design: The aims of our study were to determine the frequency of positive patch reactions and the most common allergens in patients with allergic contact dermatitis (ACD and/or mucositis(M who underwent with T.R.U.E. “Thin-layer Rapid-Use Epicutaneous” test and evaluate supplemantal series used with T.R.U.E. test effect on patch test results.Material and Method: In this study 161 ACD, 5 ACM, 1 ACD and ACM were enrolled. While 139 of all patients were patch tested with T.R.U.E. test alone,out of 28 patients were tested for T.R.U.E. test and also with supplemental series that included textile colours (9 of tested patients, plastic and glues (9, dental screening (6, backery (2, cosmetic (1 and plastic and glues and dental screening (1. Supplemental series were chosen according to patient’s occupation and clinic presentation. The data from our patients were analyzed as percentage. The relationship between contact sensitization and atopic status was evaluated with Yate’s correlation x2 test.Results: Eighty-six male, 81 female were taken into this study. The median age was 36.5.While 25.9% of 139 patients tested with T.R.U.E. test alone,46.4% of 28 patients applied supplemental series in addition to T.R.U.E. test showed positive reaction to one or more allergens. The most common allergens were nickel sulphate (14.4%, potassium dichromate (4.8%, fragrance mix (2.9% and colophony (2.9%. The most common supplemental allergens were octil gallat (50% in bakery and copper sulphate, goldsodiumthiosulphate (42.8% in dental screening. Positive patch reactions were detected 83.3% in 6 patients with AKM, 80% of these positive reactions was againts dental screening. The rate of contact sensitization between atopics and non-atopics was not significant (p>0.05. Conclusion: We suggest in presence of mucositis and/or occupational dermatoses using supplemental series in addition to T.R.U.E. test would be more beneficial in identifing the

  5. New machining and testing method of large angle infrared wedge mirror parts

    Science.gov (United States)

    Su, Ying; Guo, Rui; Zhang, Fumei; Zhang, Zheng; Liu, Xuanmin; Zengqi, Xu; Li, Wenting; Zhang, Feng

    2016-10-01

    Large angle wedge parts were widely used in the optical system that was used for achieving a wide range of scanning. Due to the parts having the characteristic of large difference in the thickness of both ends and high density, the accuracy of the wedge angle was hard to ensure to reach second level in optical processing. Generally, wedge mirror angle was measured by contact comparison method which was easy to damage the surface. In view of the existence of two practical problems, in this paper, based on theoretical analysis, by taking three key measures that were the accurate positioning for the central position of the large angle wedge part, the accuracy control of angle precision machined of wedge mirror and fast and non destructive laser assisted absolute measurement of large angle wedge, the qualified rate of parts were increased to 100%, a feasible, controllable and efficient process route for large angle infrared wedge parts was found out.

  6. Compendium of Test Results of Recent Single Event Effect Tests Conducted by the Jet Propulsion Laboratory

    Science.gov (United States)

    McClure, Steven S.; Allen, Gregory R.; Irom, Farokh; Scheick, Leif Z.; Adell, Philippe C.; Miyahira, Tetsuo F.

    2010-01-01

    This paper reports heavy ion and proton-induced single event effect (SEE) results from recent tests for a variety of microelectronic devices. The compendium covers devices tested over the last two years by the Jet Propulsion Laboratory.

  7. Evaluation of the screening test results before marriage

    Directory of Open Access Journals (Sweden)

    Süleyman Durmaz

    2011-09-01

    Full Text Available Objectives: Human immunodeficiency virus (HIV, Hepatitis B and Hepatitis C viruses and Treponema pallidum are parenterally and sexually transmitted infection agents. Screening test is made before marriage to pre-marital couples legally under the relevant legislation and legal procedures in our country; applicants are evaluated in terms of sexually transmitted diseases. The aim of this study is to evaluate pre-marital test results for HBsAg, anti-HCV, anti-HIV I/II and Treponema pallidum.Materials and methods: To make screening test before marriage, randomized 117 patients who were applied to Kızıltepe General Hospital of Infectious Diseases and Clinical Microbiology, were included in this study between January 2011 and March 2011. Of these patients, 64 were women (average age 24.7±5.7, and 55 were males (mean age 24.7±4.7. HBsAg, anti-HCV and anti-HIV I/II tests of the patients were studied by macro-ELISA device (ECIQ Vitros, Ortho Clinical Diagnostics, USA, screening of anti-Treponema pallidum IgG, IgA and IgM antibodies were studied by immunochromatographic rapid test (syphilis syphilis 3.0, Standard Diagnostics, inc. Korea.Results: Of the 119 patients, five patients (4.2% were positive for HBsAg (3 male and 2 female. Anti-HCV, anti-HIV I/II and anti-Treponema pallidum antibodies were negative in all patients.Conclusion: HBsAg test result which was obtained in present study has been found consistent with HBsAg positivity rate in our region. As a result of screening test that was done before marriage will continue to believe that the increased importance of the prevention of sexually transmitted diseases. J Clin Exp Invest 2011; 2 (3: 292-294.

  8. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2013-05-29

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and

  9. Calibration of Results of Water Meter Test Facility

    Directory of Open Access Journals (Sweden)

    Andrius Bončkus

    2011-04-01

    Full Text Available The results of water meter test facility calibration are presented. More than 30 test facilities are used in Lithuania nowadays. All of them are certificated for water meter of class 2 verification. The results of inter-laboratory comparison of multi-jet water meter calibration at flow rate Q = 5 m3/h are presented. Lithuanian Energy Institute was appointed as reference laboratory for the comparison. Twelve water meter verification and calibration laboratories from Lithuania participated in the ILC. The deviations from reference values were described by the normalized deviation En.Article in Lithuanian

  10. Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Maddalena, Randy L [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-01

    The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The other home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.

  11. Planar Pixel Sensors for the ATLAS Upgrade: Beam Tests results

    CERN Document Server

    Weingarten, J; Beimforde, M; Benoit, M; Bomben, M; Calderini, G; Gallrapp, C; George, M; Gibson, S; Grinstein, S; Janoska, Z; Jentzsch, J; Jinnouchi, O; Kishida, T; La Rosa, A; Libov, V; Macchiolo, A; Marchiori, G; Münstermann, D; Nagai, R; Piacquadio, G; Ristic, B; Rubinskiy, I; Rummler, A; Takubo, Y; Troska, G; Tsiskaridtze, S; Tsurin, I; Unno, Y; Weigel, P; Wittig, T

    2012-01-01

    Results of beam tests with planar silicon pixel sensors aimed towards the ATLAS Insertable B-Layer and High Luminosity LHC (HL-LHC) upgrades are presented. Measurements include spatial resolution, charge collection performance and charge sharing between neighbouring cells as a function of track incidence angle for different bulk materials. Measurements of n-in-n pixel sensors are presented as a function of fluence for different irradiations. Furthermore p-type silicon sensors from several vendors with slightly differing layouts were tested. All tested sensors were connected by bump-bonding to the ATLAS Pixel read-out chip. We show that both n-type and p-type tested planar sensors are able to collect significant charge even after integrated fluences expected at HL-LHC.

  12. PFR fuel cladding transient test results and analysis

    Science.gov (United States)

    Cannon, N. S.; Hunter, C. W.; Kear, K. L.; Wood, M. H.

    1986-05-01

    Fuel Cladding Transient Tests (FCTT) were performed on M316 cladding specimens obtained from mixed-oxide fuel pins irradiated in the Prototype Fast Reactor (PFR) to burnups of 4 and 9 atom percent. In these tests, specimens of fuel cladding were pressurized and heated until failure occurred. Samples of cladding from PFR fuel pins exhibited generally greater strength and ductility than specimens from Experimental Breeder Reactor-II (EBR-II) mixed-oxide fuel pins tested under similar conditions. Apparently, the PFR cladding properties were not degraded by a fuel adjacency effect (FAE) observed in fuel pin cladding from EBR-II irradiations. A recently developed model of grain boundary cavity growth was used to predict the results of the tests conducted on PFR cladding. It was found that the predicted failure temperatures for the relevant internal pressures were in good agreement with experimental failure temperatures.

  13. Selected Test Results from the Encell Technology Nickel Iron Battery

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Summer Kamal Rhodes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Baca, Wes Edmund [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Avedikian, Kristan [Encell Technology, Alachua, FL (United States)

    2014-09-01

    The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

  14. Test results on silicon micro-strip detectors for ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    DeWitt, J.; Dorfan, D.E.; Dubbs, T.; Grillo, A.A.; Kashigin, S.; Kroeger, W.; Pulliam, T.; Rahn, J.; Rowe, W.A.; Sadrozinski, H.F.-W.; Seiden, A.; Spencer, E.; Webster, A.; Wichmann, R.; Wilder, M.; Williams, D.C.; Dane, J.; Lankford, A.; Pier, S.; Schmid, B.; Bonino, R.; Couyoumtzelis, C.; Demierre, P.; Fujita, K.; Handa, T.; Iwata, Y.; Ohsugi, T.; Iwasaki, H.; Kohriki, T.; Kondo, T.; Terada, S.; Unno, Y.; Takashima, R.; Ciocio, A.; Collins, T.; Emes, J.; Gilchriese, M.G.D.; Haber, C.; Kipnis, I.; Shapiro, M.; Siegrist, J.; Spieler, H.; Moorhead, G.; Nakao, M.; Tamura, N.; Dabrowski, W.; Idzik, M.; Godlewski, J.; Grewal, A.; Nickerson, R.; Wastie, R.; Gao, Y.; Gonzalez, S.; Walsh, A.M.; Feng, Z. [California Univ., Santa Cruz, CA (United States). Inst. for Particle Phys.]|[California Univ., Irvine, CA (United States)]|[Geneva Univ. (Switzerland)]|[Hiroshima Univ. (Japan)]|[KEK, Tsukuba (Japan)]|[Kyoto Univ. Education (Japan)]|[Lawrence Berkeley National Lab., CA (United States)]|[Melbourne Univ. (Australia)]|[Okayama Univ. (Japan)]|[IPNT, Krakow (Poland)]|[INP, Krakow (Poland)]|[Oxford Univ. (United Kingdom)]|[Wisconsin Univ., Madison, WI (United States)

    1997-02-11

    We report results from beam tests on silicon microstrip detectors using a binary readout system for ATLAS. The data were collected during the H8 beam test at CERN in August/September 1995 and the KEK test in February 1996. The binary modules tested had been assembled from silicon microstrip detectors of different layout and from front-end electronics chips of different architecture. The efficiency, noise occupancy and position resolution were determined as a function of the threshold setting for various bias voltages and angles of incidence for both irradiated and non-irradiated detectors. In particular, the high spatial resolution of the beam telescope allowed the evaluation of the performance as a function of the track location in between detector strips. (orig.).

  15. Suit Port Aft Bulkhead Mockup 2008 Test Results

    Science.gov (United States)

    Romig, Barbara A.; Allton, Charles S.; Litaker, Harry L.

    2009-01-01

    The Lunar Electric Rover (LER), formerly called the Small Pressurized Rover (SPR), is currently being carried as an integral part of the current Lunar Surface Architectures under consideration in the Constellation program. One element of the LER is the suit port, the means by which the crew performs Extravehicular Activities (EVAs). Two suit port deliverables were produced in fiscal year 2008: an aft bulkhead mockup for functional integrated testing with the 1-G LER mockup and a functional and pressurizable Engineering Unit (EU). This paper focuses on the aft bulkhead mockup test results from Desert Research and Technology Studies (D-RATS) October 2008 testing at Black Point Lava Flow (BPLF), Arizona. Refer to 39th International Conference on Environmental Systems (ICES) for test results of the EU. The suit port aft bulkhead mockup was integrated with the mockup of the LER cabin and chassis. It is located on the aft bulkhead of the LER cabin structure and includes hatches, a locking mechanism, seals, interior and exterior suit don/doff aids, and exterior platforms to accommodate different crewmember heights. A lightweight mockup of the Mark III suit was tested with the suit port aft bulkhead mockup. There are several limitations to the suit port and mockup suits, and results of the suit port evaluation are presented and interpreted within the context of the limitations.

  16. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2012-11-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  17. Testing Result Statistics-Based Rapid Testing Method for Safety-Critical System

    Institute of Scientific and Technical Information of China (English)

    Zhi-Yao Deng; Nan Sang

    2008-01-01

    Safety-critical system (SCS) has highlydemand for dependability, which requires plenty ofresource to ensure that the system under test (SUT)satisfies the dependability requirement. In this paper, anew SCS rapid testing method is proposed to improveSCS adaptive dependability testing. The result of each testexecution is saved in calculation memory unit andevaluated as an algorithm model. Then the least quantityof scenario test case for next test execution will becalculated according to the promised SUT's confidencelevel. The feedback data are generated to weightcontroller as the guideline for the further testing. Finally,a compre- hensive experiment study demonstrates thatthis adaptive testing method can really work in practice.This rapid testing method, testing result statistics-basedadaptive control, makes the SCS dependability testingmuch more effective.

  18. GICHD mine dog testing project - soil sample results #4.

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.; Wood, Tyson B.; Donovan, Kelly L.; Bender, Susan Fae Ann

    2003-08-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonal weather conditions. This report documents the analytical chemical methods and results from the fourth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in April 2003 and Sarajevo, Bosnia collected in May 2003.

  19. GICHD mine dog testing project : soil sample results #5.

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.; Donovan, Kelly L.; Bender, Susan Fae Ann

    2004-01-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonal weather conditions. This report documents the analytical chemical methods and results from the fifth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in June 2003.

  20. Test results of a shower water recovery system

    Science.gov (United States)

    Verostko, Charles E.; Price, Donald F.; Garcia, Rafael; Pierson, Duane L.; Sauer, Richard L.

    1987-01-01

    A shower test was conducted recently at NASA-JSC in which waste water was reclaimed and reused. Test subjects showered in a prototype whole body shower following a protocol similar to that anticipated for Space Station. The waste water was purified using reverse osmosis followed by filtration through activated carbon and ion exchange resin beds. The reclaimed waste water was maintained free of microorganisms by using both heat and iodine. This paper discusses the test results, including the limited effectiveness of using iodine as a disinfectant and the evaluation of a Space Station candidate soap for showering. In addition, results are presented on chemical and microbial impurity content of water samples obtained from various locations in the water recovery process.

  1. Guidelines to Interpret Results of Mechanical Blade Test

    Energy Technology Data Exchange (ETDEWEB)

    Arias Vega, F.; Sanz Martin, J. C. [Ciemat, Madrid (Spain)

    2000-07-01

    This report shows the interpretation of full scale rotor blade test results and describes the engineering testing models and coefficients for any feasible rotor blade design, in order to accept and to certify any final manufactured blades as an allowable product, fit for use and working with a completely security during all the windturbine's lifetime. This work was carried out at the Wind Energy Division of the CIEMAT.DER and it is based on the author's technical experience in this field, after many years working on testing blades. Also, this paper contains results of the European wind turbine Standards II relevant to the European Project: JOULE III R.D. where the Wind Energy Division took part as participant too. (Author)

  2. Results for the Brine Evaporation Bag (BEB) Brine Processing Test

    Science.gov (United States)

    Delzeit, Lance; Flynn, Michael; Fisher, John; Shaw, Hali; Kawashima, Brian; Beeler, David; Howard, Kevin

    2015-01-01

    The recent Brine Processing Test compared the NASA Forward Osmosis Brine Dewatering (FOBD), Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB). This paper reports the results of the BEB. The BEB was operated at 70 deg C and a base pressure of 12 torr. The BEB was operated in a batch mode, and processed 0.4L of brine per batch. Two different brine feeds were tested, a chromic acid-urine brine and a chromic acid-urine-hygiene mix brine. The chromic acid-urine brine, known as the ISS Alternate Pretreatment Brine, had an average processing rate of 95 mL/hr with a specific power of 5kWhr/L. The complete results of these tests will be reported within this paper.

  3. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  4. SSPS results of test and operation, 1981-1984

    Energy Technology Data Exchange (ETDEWEB)

    None

    1985-05-01

    The results of three years of testing and operation of the two dissimilar solar thermal power plants of the SSPS project are summarized. The project includes: (1) a Distributed Collector System, and (2) a Central Receiver System. Environmental conditions are presented and an economical assessment of the project is provided. (BCS)

  5. ATLAS Transition Radiation Tracker test-beam results

    CERN Document Server

    Åkesson, T; Baker, K; Baron, S; Benjamin, D; Bertelsen, H; Bondarenko, V; Bychkov, V; Callahan, J; Capéans-Garrido, M; Cardiel-Sas, L; Catinaccio, A; Cetin, S A; Cwetanski, Peter; Dam, M; Danielsson, H; Dittus, F; Dolgoshein, B A; Dressnandt, N; Driouichi, C; Ebenstein, W L; Eerola, Paule Anna Mari; Farthouat, Philippe; Fedin, O; Froidevaux, D; Gagnon, P; Grichkevitch, Y; Grigalashvili, N S; Hajduk, Z; Hansen, P; Kayumov, F; Keener, P T; Kekelidze, G D; Khristatchev, A; Konovalov, S; Koudine, L; Kovalenko, S; Kowalski, T; Kramarenko, V A; Krüger, K; Laritchev, A; Lichard, P; Luehring, F C; Lundberg, B; Maleev, V; Markina, I; McFarlane, K W; Mialkovski, V; Mitsou, V A; Mindur, B; Morozov, S; Munar, A; Muraviev, S; Nadtochy, A; Newcomer, F M; Ögren, H O; Oh, S H; Oleshko, S; Olszowska, J; Passmore, S; Patritchev, S; Peshekhonov, V D; Petti, R; Price, M; Rembser, C; Rohne, O; Romaniouk, A; Rust, D R; Ryabov, Yu; Shchegelskii, V; Seliverstov, D M; Shin, T; Shmeleva, A; Smirnov, S; Sosnovtsev, V V; Soutchkov, V; Spiridenkov, E; Tikhomirov, V; Van Berg, R; Vassilakopoulos, V I; Vassilieva, L; Wang, C; Williams, H H; Zalite, A

    2004-01-01

    Several prototypes of the Transition Radiation Tracker for the ATLAS experiment at the LHC have been built and tested at the CERN SPS accelerator. Results from detailed studies of the straw-tube hit registration efficiency and drift-time measurements and of the pion and electron spectra without and with radiators are presented. (10 refs).

  6. Recent results on the RIA test in IGR reactor

    Energy Technology Data Exchange (ETDEWEB)

    Asmolov, V.; Yegorova, L. [Nuclear Safety Institute, Moscow (Russian Federation)

    1997-01-01

    At the 23d WRSM meeting the data base characterizing results of VVER high burnup fuel rods tests under reactivity-initiated accident (RIA) conditions was presented. Comparison of PWR and VVER failure thresholds was given also. Additional analysis of the obtained results was being carried out during 1996. The results of analysis show that the two different failure mechanisms were observed for PWR and VVER fuel rods. Some factors which can be as the possible reasons of these differences are presented. First of them is the state of preirradiated cladding. Published test data for PWR high burnup fuel rods demonstrated that the PWR high burnup fuel rods failed at the RIA test are characterized by very high level of oxidation and hydriding for the claddings. Corresponding researches were performed at Institute of Atomic Reactors (RLAR, Dimitrovgrad, Russia) for large set of VVER high burnup fuel rods. Results of these investigations show that preirradiated commercial Zr-1%Nb claddings practically keep their initial levels of oxidation and H{sub 2} concentration. Consequently the VVER preirradiated cladding must keep the high level of mechanical properties. The second reason leading to differences between failure mechanisms for two types of high burnup fuel rods can be the test conditions. Now such kind of analysis have been performed by two methods.

  7. Test Beam Results Obtained with the Q4 Prototype

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Benitez, M.; Alberdi, J.; Cerrada, M.; Colino, N.; Daniel, M.; Fouz, M. c.; Marin, J.; Mocholi, J.; Oller, J. C.; Puerta, J.; Romero, L.; Salicio, J. M.

    2000-07-01

    A prototype of the CMS Barrel Muon Detector incorporating all the features of the final chambers was built at CIEMAT using the mass production assembly procedures and tools. The performance of this prototype was studied in a muon test beam at CERN and the results obtained are presented here. (Author)

  8. Li-Ion Cell Lot Testing and Flight Screening Results

    Science.gov (United States)

    2011-02-01

    than \\c7<. Results arc shown in Table 4. Table 4 Moli-Energ) Li-Ion Cell Weights Alter Vaeuun Leak Tesi Initial Final Final Weight Weight...All tested cells were within 95 *5! o\\ their initial capacity. Note: Cells C009 and C023 were misplaced following being weighed after the vac- uum

  9. Evaluation of the ductile-to-brittle transition temperature of a silicon steel under various strain rate conditions with a servo-hydraulic high speed testing machine

    Science.gov (United States)

    Kwon, Junbeom; Huh, Hoon; Kim, Jae-song

    2017-07-01

    This paper is concerned with the construction of an empirical model of the Ductile-to-Brittle Transition Temperature (DBTT) for 3.4% silicon steel based on tensile test results at strain rates ranging from 0.001 s‒1 to 100 s‒1. Dynamic tensile tests are conducted using an in-house servo hydraulic tensile test machine at strain rates of 1 s‒1, 10 s‒1, and 100 s‒1 and quasi-static tensile tests are conducted using Instron 4206 at strain rates of 0.001 s‒1 and 0.01 s‒1 with an environmental chamber. Fracture elongations are measured by a DIC method during all tests using the high-speed camera for accurate measurement. The DBTT of 3.4% silicon steel is presented in terms of fracture strain with the variation of the temperature and the strain rate. It is demonstrated from the test results that the DBTT increases as the strain rate increases. An empirical model of the DBTT is constructed in terms of strain rate, temperature and fracture elongation. The parameters of the empirical model are calculated from experimental results obtained at various temperatures and strain rates.

  10. Large-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Bontha, Jagannadha R.; Daniel, Richard C.; Kurath, Dean E.; Adkins, Harold E.; Billing, Justin M.; Burns, Carolyn A.; Davis, James M.; Enderlin, Carl W.; Fischer, Christopher M.; Jenks, Jeromy WJ; Lukins, Craig D.; MacFarlan, Paul J.; Shutthanandan, Janani I.; Smith, Dennese M.

    2012-12-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  11. Graphite electrode arc melter demonstration Phase 2 test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; O`Connor, W.K.; Oden, L.L.; Turner, P.C.

    1996-06-01

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau`s Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of {open_quotes}as-received{close_quotes} heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process.

  12. Long Term Corrosion/Degradation Test Six Year Results

    Energy Technology Data Exchange (ETDEWEB)

    M. K. Adler Flitton; C. W. Bishop; M. E. Delwiche; T. S. Yoder

    2004-09-01

    The Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) contains neutron-activated metals from non-fuel, nuclear reactor core components. The Long-Term Corrosion/Degradation (LTCD) Test is designed to obtain site-specific corrosion rates to support efforts to more accurately estimate the transfer of activated elements to the environment. The test is using two proven, industry-standard methods—direct corrosion testing using metal coupons, and monitored corrosion testing using electrical/resistance probes—to determine corrosion rates for various metal alloys generally representing the metals of interest buried at the SDA, including Type 304L stainless steel, Type 316L stainless steel, Inconel 718, Beryllium S200F, Aluminum 6061, Zircaloy-4, low-carbon steel, and Ferralium 255. In the direct testing, metal coupons are retrieved for corrosion evaluation after having been buried in SDA backfill soil and exposed to natural SDA environmental conditions for times ranging from one year to as many as 32 years, depending on research needs and funding availability. In the monitored testing, electrical/resistance probes buried in SDA backfill soil will provide corrosion data for the duration of the test or until the probes fail. This report provides an update describing the current status of the test and documents results to date. Data from the one-year and three-year results are also included, for comparison and evaluation of trends. In the six-year results, most metals being tested showed extremely low measurable rates of general corrosion. For Type 304L stainless steel, Type 316L stainless steel, Inconel 718, and Ferralium 255, corrosion rates fell in the range of “no reportable” to 0.0002 mils per year (MPY). Corrosion rates for Zircaloy-4 ranged from no measurable corrosion to 0.0001 MPY. These rates are two orders of magnitude lower than those specified in

  13. RESULTS OF COMPRESSION TESTING ON PSEUDO-COHESIVE SOIL

    Directory of Open Access Journals (Sweden)

    Ofrikhter Vadim Grigor’evich

    2015-09-01

    Full Text Available Natural non-treated sand reinforced with randomly oriented short polypropylene fibers of 12 mm in length was tested to determine creep characteristics. This study is a part of the research aimed at encouraging fibrosand (FRS application in subsoils, embankments and retaining wall constructions. Fiber content was accounted for 0.93 %. Twin specimens were put to creep tests (1-D compression using the two curve method. The test results were analyzed and checked with the use of ageing, hardening and hereditary creep theories. On the basis of approximation of the test results the creep deformation equation at constant stress for tested fibrosand was obtained. The assessment of fibrosand secondary compression was carried out by the FORE method. As a result, the value of the void ratio by the end of the secondary compression had been eu=0.7041. For determination of the beginning of the secondary compression the rate equation was superimposed on the empirical curve. The point of the graph divergence is the beginning of the secondary compression process. The secondary compression had begun by the time moment being equal to 9360 min. The void ratio by the beginning of the secondary compression had amounted to 0.70574. Fibrosand is a specific type of improved soil relating to so-called pseudo-cohesive soil. This type of soil is characterized by cohesion like cohesive soils, but, at the same time, by the filtration coefficient of about 1 m per day like non-cohesive soils. Pseudo-cohesive soil testing helps to understand the distinctive features of the stress-strain state of this kind of materials. Municipal solid waste also relates to them.

  14. Définition d'une pièce test pour la caractérisation d'une machine UGV

    CERN Document Server

    Mawussi, Kwamiwi

    2009-01-01

    In several fields like aeronautics, die and automotive, the machining of the parts is done more and more on high speed machines tools. Today, the offer for purchasing these machine tools is very wide. This situation poses the problem of the judicious and objective choice meeting industrial needs that must be necessary well expressed. The choice remains difficult insofar as the technical data provided to the customers by the manufacturers of machine tools are insufficient as well quantitatively as qualitatively. In this paper we present a protocol for the characterization of machines tools in order to direct the choice. The protocol is based on the one hand on no-load complementary tests to those recommended by the standards ISO 230 and ISO 10791 and on the other hand on the tests in load on a part test. In the first part, we present the industrial needs as well as an analysis of the technical data of machine tools. The second part is devoted to the study of the standards, the description of the protocol and t...

  15. High Temperature Superconductor Machine Prototype

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech; Træholt, Chresten

    2011-01-01

    A versatile testing platform for a High Temperature Superconductor (HTS) machine has been constructed. The stationary HTS field winding can carry up to 10 coils and it is operated at a temperature of 77K. The rotating armature is at room temperature. Test results and performance for the HTS field...

  16. Patch Test Results of 775 Patients with Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Simin Ada

    2010-12-01

    Full Text Available Background and Design: The allergens responsible for allergic contact dermatitis vary among countries and even between different geographical regions within the same country over time. It is of great importance to perform the patch test at certain intervals, to evaluate the results in different centers and to compare them afterwards. Our aim was to evaluate the patch test results in our patients with allergic contact dermatitis.Material and Method: The records of the patients with allergic contact dermatitis, who had been patch tested between May 1997 and March 2009, were analyzed retrospectively. The demographic features such as age and sex, localization of the contact dermatitis, and the patch test results were recorded. Results: Of the 775 patients, 581 (75.2% were females and 194 (25% males. Of all patients, 735 were patch tested with the European Standard Series, 318 - with both the European Standard Series and cosmetic series, and 40-with cosmetic series alone. Of the patients tested with the European Standard Series, 255 (34.7% had at least one positive reaction. The most frequent allergen in the European Standard Series was nickel sulfate (17.3%, followed by cobalt chloride (7.2%, potassium dichromate (3%, fragrance mix (2.9%, and p-phenylenediamine base (2.6%. Of the 358 patients tested with cosmetic series, 82 (22.9% had at least one positive reaction. The 5 most frequently observed cosmetic series allergens were octyl gallate (3.9%, thimerosal (2.2%, sorbitan sesquioleate (2%, Euxyl K 400 (2% and methyldibromo glutaronitrile (1.4%. Conclusion: Our study shows the contact allergen profile of our center over 12 years. The most common allergens and their frequency differ between centers in various cities in Turkey. Those geographical differences should be re-evaluated by further studies performed in the certain time period. The high frequency of reactions to octyl gallate is an important finding in patients suspected of cosmetic allergy

  17. ITER CS Model Coil and CS Insert Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, N; Michael, P; Minervina, J; Radovinsky, A; Takayasu, M; Thome, R; Ando, T; Isono, T; Kato, T; Nakajima, H; Nishijima, G; Nunoya, Y; Sugimoto, M; Takahashi, Y; Tsuji, H; Bessette, D; Okuno, K; Ricci, M

    2000-09-07

    The Inner and Outer modules of the Central Solenoid Model Coil (CSMC) were built by US and Japanese home teams in collaboration with European and Russian teams to demonstrate the feasibility of a superconducting Central Solenoid for ITER and other large tokamak reactors. The CSMC mass is about 120 t, OD is about 3.6 m and the stored energy is 640 MJ at 46 kA and peak field of 13 T. Testing of the CSMC and the CS Insert took place at Japan Atomic Energy Research Institute (JAERI) from mid March until mid August 2000. This paper presents the main results of the tests performed.

  18. Results of pollution research and tests at CPRI, Hyderabad

    Energy Technology Data Exchange (ETDEWEB)

    Nirgude, P.M.; Devendranath, D.; Chandrakanth, N.S.; Shivakumara Aradhya, R.S.; Channakeshava [Central Power Research Inst., Bangalore (India)

    1997-12-31

    The design of electrical insulation from the point of view of pollution performance was discussed. A pollution laboratory was established at Hyderabad, India, to perform tests on insulators under polluted conditions in the EHV and UHV range. These tests determined the insulation strength of different types of insulators under polluted conditions. Studies have been conducted on the pollution performance of line and post insulators under AC voltages using the salt fog method. The following insulator parameters that affect pollution performance were examined: creepage length, diameter, shape and string length. Results showed an increase in leakage current with specific creepage length. 9 refs., 1 tab., 5 figs.

  19. Overview of Linear Collider Test Facilities and Results

    CERN Document Server

    Hayano, H

    2004-01-01

    Linear Collider technology will be recommended by the International Technology Recommendation Panel (ITRP) to the International Linear Collider Steering Committee (ILCSC), soon. Towards this recommendation, many efforts of the developments and the output results of each technology have been made to satisfy the requirements of the technical review committee report (TRC). The test facilities of each linear collider design are the place of the key technology demonstration and realization. The overview of the LC test facilities activities and outputs of TTF, NLCTA, ATF/GLCTA and CTF are summarized and reviewed.

  20. PISA TESTS IN LATIN AMERICA: RESULTS IN CONTEXT

    Directory of Open Access Journals (Sweden)

    Guillermina Tiramonti

    2014-05-01

    Full Text Available The educational reforms implemented in Latin America in the ‘90s introduced changes in the modes of regulation of educational systems based on the adoption of mechanisms for assessing student achievement. Since 2000, eight Latin-American countries (Argentina, Chile, Uruguay, Colombia, Brazil, Costa Rica, Mexico and Peru are involved in the PISA tests. The article presents a brief review of the social and educational situation of the Region, relevant for the interpretation and comparative analysis of the results of these tests that is presented below.

  1. APALS program status: preproduction flight test results and production implementation

    Science.gov (United States)

    Hvizd, James J.; Dieffenbach, Otto W.

    1996-05-01

    The APALS system is a precision approach and landing system designed to enable low visibility landings at many more airports than now possible. Engineering development of the APALS system began October 1992 culminating in the pre- production Advanced Development Model (ADM) system currently undergoing flight testing. The paper focuses on the Cat III accuracy and integrity requirements defined by ICAO, Annex 10 and the required navigation performance (RNP) tunnel concept. The resulting ADM architecture developed to meet them is described. The primary measurement is made with the aircraft's weather radar and provides range and range rate information to the ADM necessary to update the precision navigation state vector. The system uses stored terrain map data as references for map matching with synthetic aperture radar with synthetic aperture radar maps. A description of the pre-production flight test program is included. Testing is being conducted at six different airports around the country demonstrating system performance in various environmental conditions (precipitation, heavy foliage, sparse terrain, over water and turbulence). ADM flight test results of 131 successful CAT II hand-flown approaches at ALbuquerque, NM and Richmond, VA are presented. Detailed statistical analysis of these results indicate that the APALS system meets the RNP for Cat III.

  2. Machine Perfusion of Porcine Livers with Oxygen-Carrying Solution Results in Reprogramming of Dynamic Inflammation Networks

    Directory of Open Access Journals (Sweden)

    David Sadowsky

    2016-11-01

    Full Text Available Background: Ex vivo machine perfusion (MP can better preserve organs for transplantation. We have recently reported on the first application of a MP protocol in which liver allografts were fully oxygenated, under dual pressures and subnormothermic conditions, with a new hemoglobin-based oxygen carrier solution specifically developed for ex vivo utilization. In those studies, MP improved organ function post-operatively and reduced inflammation in porcine livers. Herein, we sought to refine our knowledge regarding the impact of MP by defining dynamic networks of inflammation in both tissue and perfusate. Methods: Porcine liver allografts were preserved either with MP (n = 6 or with cold static preservation (CSP; n = 6, then transplanted orthotopically after 9 h of preservation. Fourteen inflammatory mediators were measured in both tissue and perfusate during liver preservation at multiple time points, and analyzed using Dynamic Bayesian Network (DyBN inference to define feedback interactions, as well as Dynamic Network Analysis (DyNA to define the time-dependent development of inflammation networks.Results: Network analyses of tissue and perfusate suggested an NLRP3 inflammasome-regulated response in both treatment groups, driven by the pro-inflammatory cytokine interleukin (IL-18 and the anti-inflammatory mediator IL-1 receptor antagonist (IL-1RA. Both DyBN and DyNA suggested a reduced role of IL-18 and increased role of IL-1RA with MP, along with increased liver damage with CSP. DyNA also suggested divergent progression of responses over the 9 h preservation time, with CSP leading to a stable pattern of IL-18-induced liver damage and MP leading to a resolution of the pro-inflammatory response. These results were consistent with prior clinical, biochemical, and histological findings after liver transplantation. Conclusion: Our results suggest that analysis of dynamic inflammation networks in the setting of liver preservation may identify novel

  3. 688,112 statistical results : Content mining psychology articles for statistical test results

    NARCIS (Netherlands)

    Hartgerink, C.H.J.

    2016-01-01

    In this data deposit, I describe a dataset that is the result of content mining 167,318 published articles for statistical test results reported according to the standards prescribed by the American Psychological Association (APA). Articles published by the APA, Springer, Sage, and Taylor & Francis

  4. Interim Guidance for Interpretation of Zika Virus Antibody Test Results.

    Science.gov (United States)

    Rabe, Ingrid B; Staples, J Erin; Villanueva, Julie; Hummel, Kimberly B; Johnson, Jeffrey A; Rose, Laura; Hills, Susan; Wasley, Annemarie; Fischer, Marc; Powers, Ann M

    2016-06-03

    Zika virus is a single-stranded RNA virus in the genus Flavivirus and is closely related to dengue, West Nile, Japanese encephalitis, and yellow fever viruses (1,2). Among flaviviruses, Zika and dengue virus share similar symptoms of infection, transmission cycles, and geographic distribution. Diagnostic testing for Zika virus infection can be accomplished using both molecular and serologic methods. For persons with suspected Zika virus disease, a positive real-time reverse transcription-polymerase chain reaction (rRT-PCR) result confirms Zika virus infection, but a negative rRT-PCR result does not exclude infection (3-7). In these cases, immunoglobulin (Ig) M and neutralizing antibody testing can identify additional recent Zika virus infections (6,7). However, Zika virus antibody test results can be difficult to interpret because of cross-reactivity with other flaviviruses, which can preclude identification of the specific infecting virus, especially when the person previously was infected with or vaccinated against a related flavivirus (8). This is important because the results of Zika and dengue virus testing will guide clinical management. Pregnant women with laboratory evidence of Zika virus infection should be evaluated and managed for possible adverse pregnancy outcomes and be reported to the U.S. Zika Pregnancy Registry or the Puerto Rico Zika Active Pregnancy Surveillance System for clinical follow-up (9,10). All patients with clinically suspected dengue should have proper management to reduce the risk for hemorrhage and shock (11). If serologic testing indicates recent flavivirus infection that could be caused by either Zika or dengue virus, patients should be clinically managed for both infections because they might have been infected with either virus.

  5. Cold test results for the test cavities w/out the deposited lead photo cathode

    CERN Document Server

    Sekutowicz, J

    2013-01-01

    In this report we present tests of a 1.5-cell superconducting photo-injector cavity, which was built in the frame of Task 4. The cavity was tested twice: without the cathode (baseline test) and with the lead photo-cathode. The result of tests was very encouraging and the decision was made to continue the experiment, beyond scope of the task, at HZB in Berlin to learn more about quality of the cathode.

  6. Performance tests on large-hole drilling machines; Leistungsanalyse an Grosslochdrehbohrgeraeten

    Energy Technology Data Exchange (ETDEWEB)

    Schumacher, L. [TU Bergakademie Freiberg (Germany). Inst. fuer Maschinenbau

    2004-09-01

    In the civil engineering industry loose-rock drilling both with and without material excavation forms the basis for many different types of construction project. When setting situ-cast piles the industry now often employs a casing pipe which is installed either by rotary or oscillatory means to serve as a support pipe and/or wash pipe. Dewatering and ground water-lowering ahead of opencast mining operations calls for the preparation of filtering wells whose cavity excavations are also produced using cased boreholes. The frictional resistance of the casing acts between the pipe and the loose ground and is determined by machine- and process-dependent factors as well as by soil-mechanical parameters. The paper presents the main performance-determining relationships, as obtained by both theoretical and empirical studies, which influence the amount of torque that is required during the casing process in order to overcome the peripheral friction and uses survey measurements to support the findings. (orig.)

  7. Design of Demining Machines

    CERN Document Server

    Mikulic, Dinko

    2013-01-01

    In constant effort to eliminate mine danger, international mine action community has been developing safety, efficiency and cost-effectiveness of clearance methods. Demining machines have become necessary when conducting humanitarian demining where the mechanization of demining provides greater safety and productivity. Design of Demining Machines describes the development and testing of modern demining machines in humanitarian demining.   Relevant data for design of demining machines are included to explain the machinery implemented and some innovative and inspiring development solutions. Development technologies, companies and projects are discussed to provide a comprehensive estimate of the effects of various design factors and to proper selection of optimal parameters for designing the demining machines.   Covering the dynamic processes occurring in machine assemblies and their components to a broader understanding of demining machine as a whole, Design of Demining Machines is primarily tailored as a tex...

  8. Results of the quality assurance testing program for radiopharmaceuticals 1995

    Energy Technology Data Exchange (ETDEWEB)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( {sup 99m}Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [{sup 201}Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs.

  9. Initial CGE Model Results Summary Exogenous and Endogenous Variables Tests

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Brian Keith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Boero, Riccardo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rivera, Michael Kelly [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-07

    The following discussion presents initial results of tests of the most recent version of the National Infrastructure Simulation and Analysis Center Dynamic Computable General Equilibrium (CGE) model developed by Los Alamos National Laboratory (LANL). The intent of this is to test and assess the model’s behavioral properties. The test evaluated whether the predicted impacts are reasonable from a qualitative perspective. This issue is whether the predicted change, be it an increase or decrease in other model variables, is consistent with prior economic intuition and expectations about the predicted change. One of the purposes of this effort is to determine whether model changes are needed in order to improve its behavior qualitatively and quantitatively.

  10. Dipole model test with one superconducting coil; results analysed

    CERN Document Server

    Durante, M; Ferracin, P; Fessia, P; Gauthier, R; Giloux, C; Guinchard, M; Kircher, F; Manil, P; Milanese, A; Millot, J-F; Muñoz Garcia, J-E; Oberli, L; Perez, J-C; Pietrowicz, S; Rifflet, J-M; de Rijk, G; Rondeaux, F; Todesco, E; Viret, P; Ziemianski, D

    2013-01-01

    This report is the deliverable report 7.3.1 “Dipole model test with one superconducting coil; results analysed “. The report has four parts: “Design report for the dipole magnet”, “Dipole magnet structure tested in LN2”, “Nb3Sn strand procured for one dipole magnet” and “One test double pancake copper coil made”. The 4 report parts show that, although the magnet construction will be only completed by end 2014, all elements are present for a successful completion. Due to the importance of the project for the future of the participants and given the significant investments done by the participants, there is a full commitment to finish the project.

  11. Dipole model test with one superconducting coil: results analysed

    CERN Document Server

    Bajas, H; Benda, V; Berriaud, C; Bajko, M; Bottura, L; Caspi, S; Charrondiere, M; Clément, S; Datskov, V; Devaux, M; Durante, M; Fazilleau, P; Ferracin, P; Fessia, P; Gauthier, R; Giloux, C; Guinchard, M; Kircher, F; Manil, P; Milanese, A; Millot, J-F; Muñoz Garcia, J-E; Oberli, L; Perez, J-C; Pietrowicz, S; Rifflet, J-M; de Rijk, G; Rondeaux, F; Todesco, E; Viret, P; Ziemianski, D

    2013-01-01

    This report is the deliverable report 7.3.1 “Dipole model test with one superconducting coil; results analysed “. The report has four parts: “Design report for the dipole magnet”, “Dipole magnet structure tested in LN2”, “Nb3Sn strand procured for one dipole magnet” and “One test double pancake copper coil made”. The 4 report parts show that, although the magnet construction will be only completed by end 2014, all elements are present for a successful completion. Due to the importance of the project for the future of the participants and given the significant investments done by the participants, there is a full commitment to finish the project.

  12. Design and Test on Sowing Device of the Multi-functional Machine for Rice-wheat Cyclic Planting

    Directory of Open Access Journals (Sweden)

    Yulun Chen

    2015-02-01

    Full Text Available In order to effectively eliminate the disadvantages of improper disposing of residues and fully exploit the advantages of no-tillage seed drill technology, a machine for rice-wheat cyclic planting was developed by designing and attaching drilling and ditching assembly to a combine harvesting assembly. Tests carried out on drilling practice showed that, multi-functional machine for rice-wheat rotation, rubber track was adopted to substitute the traditional land wheel for drilling driving, cannot only effectively get rid of the intermittent drilling, but also can easily achieve the speed synchronization of harvesting and sowing practice; within the limitation of designed walking velocity, mean values of the row consistency and stability of seeding quantity as well as seeding uniformity were 93.9±1.4%, 98.4±0.5% and 76.2±5.3% respectively, which could meet the performance requirement of rice direct seeding with soil cover; for a suitable broken rate, the working length of the fluted roller is preferred to be not less than 9.4 mm if NJ210-80 roller feed was chosen to drill rice, the transmission ratio can be increased to reduce the rotary speed of the fluted roller to acquire a suitable seeding quantity, if the value exceeds the agronomic requirement of the local seeding date.

  13. Testing the portal imager GLAaS algorithm for machine quality assurance

    Directory of Open Access Journals (Sweden)

    Fogliata A

    2008-05-01

    Full Text Available Abstract Background To report about enhancements introduced in the GLAaS calibration method to convert raw portal imaging images into absolute dose matrices and to report about application of GLAaS to routine radiation tests for linac quality assurance procedures programmes. Methods Two characteristic effects limiting the general applicability of portal imaging based dosimetry are the over-flattening of images (eliminating the "horns" and "holes" in the beam profiles induced by the presence of flattening filters and the excess of backscattered radiation originated by the detector robotic arm supports. These two effects were corrected for in the new version of GLAaS formalism and results are presented to prove the improvements for different beams, detectors and support arms. GLAaS was also tested for independence from dose rate (fundamental to measure dynamic wedges. With the new corrections, it is possible to use GLAaS to perform standard tasks of linac quality assurance. Data were acquired to analyse open and wedged fields (mechanical and dynamic in terms of output factors, MU/Gy, wedge factors, profile penumbrae, symmetry and homogeneity. In addition also 2D Gamma Evaluation was applied to measurement to expand the standard QA methods. GLAaS based data were compared against calculations on the treatment planning system (the Varian Eclipse and against ion chamber measurements as consolidated benchmark. Measurements were performed mostly on 6 MV beams from Varian linacs. Detectors were the PV-as500/IAS2 and the PV-as1000/IAS3 equipped with either the robotic R- or Exact- arms. Results Corrections for flattening filter and arm backscattering were successfully tested. Percentage difference between PV-GLAaS measurements and Eclipse calculations relative doses at the 80% of the field size, for square and rectangular fields larger than 5 × 5 cm2 showed a maximum range variation of -1.4%, + 1.7% with a mean variation of For Dynamic wedges, percentage

  14. DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

    2012-09-20

    Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected

  15. Small-Scale Spray Releases: Orifice Plugging Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Blanchard, Jeremy; Kimura, Marcia L.; Kurath, Dean E.

    2012-09-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities, is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations published in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials present in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty introduced by extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches in which the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are largely absent. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine the aerosol release fractions and aerosol generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents (AFA) was assessed with most of the simulants. Orifices

  16. Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures - Test Results

    Science.gov (United States)

    Wright, Sarah E.; Ungar, Eugene K.

    2017-01-01

    Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the testing that was performed in early and mid-2017. The test article and the temporary thermocouple attachment methods tested are described. During the first test, fully half of the thermocouples detached - although the detachment showed subtly in the data for some. The second test was performed to confirm the data from the first test and to investigate the effect of test article and thermocouple grounding. The results of the testing over temperatures ranging from -150 to 200degF are detailed and preliminary recommendations are made for temporary thermocouple attachment methods.

  17. When Machines Design Machines!

    DEFF Research Database (Denmark)

    2011-01-01

    Until recently we were the sole designers, alone in the driving seat making all the decisions. But, we have created a world of complexity way beyond human ability to understand, control, and govern. Machines now do more trades than humans on stock markets, they control our power, water, gas...... and food supplies, manage our elevators, microclimates, automobiles and transport systems, and manufacture almost everything. It should come as no surprise that machines are now designing machines. The chips that power our computers and mobile phones, the robots and commercial processing plants on which we...... depend, all are now largely designed by machines. So what of us - will be totally usurped, or are we looking at a new symbiosis with human and artificial intelligences combined to realise the best outcomes possible. In most respects we have no choice! Human abilities alone cannot solve any of the major...

  18. Large-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Gauglitz, Phillip A.; Burns, Carolyn A.; Fountain, Matthew S.; Shimskey, Rick W.; Billing, Justin M.; Bontha, Jagannadha R.; Kurath, Dean E.; Jenks, Jeromy WJ; MacFarlan, Paul J.; Mahoney, Lenna A.

    2013-08-01

    One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used

  19. Machine tool structures

    CERN Document Server

    Koenigsberger, F

    1970-01-01

    Machine Tool Structures, Volume 1 deals with fundamental theories and calculation methods for machine tool structures. Experimental investigations into stiffness are discussed, along with the application of the results to the design of machine tool structures. Topics covered range from static and dynamic stiffness to chatter in metal cutting, stability in machine tools, and deformations of machine tool structures. This volume is divided into three sections and opens with a discussion on stiffness specifications and the effect of stiffness on the behavior of the machine under forced vibration c

  20. Fan Noise Source Diagnostic Test: Tone Modal Structure Results

    Science.gov (United States)

    Heidelberg, Laurence J.

    2002-01-01

    This investigation is part of a test series that was extremely comprehensive and included aerodynamic and acoustic testing of a fan stage using two different fan rotors and three different stator designs. The test series is known as the Source Diagnostic Test (SDT) and was conducted by NASA Glenn as part of the Advanced Subsonic Technology (AST) Noise Reduction Program. Tone mode measurements of one of the rotors with three different stators were made. The stator designs involve changes in vane count and sweep at constant solidity. The results of both inlet and exhaust tone mode measurements are presented in terms of mode power for both circumferential and radial mode orders. The results show benefits of vane sweep to be large, up to 13 dB in total tone power. At many conditions, the increase in power due to cutting on the rotor/stator interaction is more than offset by vane sweep. The rotor locked mode is shown as an important contributor to tone power when the blade tip speed is near and above Mach one. This is most evident in the inlet when the direct rotor field starts to cut on.

  1. Production Facility Prototype Blower 1000 Hour Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-18

    The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was need for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is now installed at the LANL facility for target and component flow testing. Two extended test of >1000 hr operation have been completed. Those results and discussion thereof are reported herein. Also included in Appendix A is the detailed description of the blower and its installation, while Appendix B documents the pressure vessel design analysis. The blower has been operated for 1000 hours as a preliminary investigation of long term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced. Test results and conclusions are in Appendix B.

  2. Production Facility Prototype Blower 1000 Hour Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-18

    The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was needed for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is now installed at the LANL facility for target and component flow testing. Two extended tests of >1000 hr operation have been completed. Those results and discussion thereof are reported herein. Also included in Appendix A is the detailed description of the blower and its installation, while Appendix B documents the pressure vessel design analysis. The blower has been operated for 1000 hours as a preliminary investigation of long-term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced. Test results and conclusions are in Appendix B.

  3. Sipping machine control system new design to perform integrity of nuclear fuel test in Cofrentes power plant

    Energy Technology Data Exchange (ETDEWEB)

    Palomo, M., E-mail: mpalomo@iqn.upv.es [Departamento de Ingenieria Quimica y Nuclear. Universidad Politecnica de Valencia (Spain); Urrea, M., E-mail: Matias.urrea@iberdrola.es [C.N.Cofrentes - Iberdrola Generacion S.A., Cofrentes, Valencia (Spain); Curiel, M., E-mail: m.curiel@lainsa.com [LAINSA Grupo Dominguis, Valencia (Spain); Arnaldos, A., E-mail: a.arnaldos@titaniast.com [TITANIA Servicios Tecnologicos SL, Grupo Dominguis, Valencia (Spain)

    2011-07-01

    This paper we present is related to SIPPING machine control system new design to perform integrity of nuclear fuel test. This test is a non destructive technique used for evaluating the radiated nuclear fuel coating structural integrity. It is based on the radioactive emission detection of fission elements in the reactor cooling system, using the fuel inspection equipment (SIPPING). SIPPING equipment consists of one simultaneous test bell-shaped vessel of eight fuel elements, and another one for individual element test, a control workstation and some accessories (cables, thermocouples, hoses). SIPPING inspection is carried out by means of fuel element vessel. Through air injection, water flows around the element and heat evacuation is reduced, so fuel elements temperature increases. Those elements with faults shall expelled fission components dissolved in water and/or as a gas component. The project aim is the SIPPING system control design and software based on LabVIEW, for control, monitoring and documentation of the SIPPING Test. This project shall give a major functionality to the system and, at the same time, shall facilitate the user a friendlier and interactive environment allowing: to substitute the present work platform with a real-time electronic system based on cRIO and a control software ad-hoc designed for SIPPING system; to equip new system of a major redundancy for data storage, minimising loss probability of the same. (author)

  4. Sipping machine control system new design to perform integrity of nuclear fuel test in Cofrentes power plant

    Energy Technology Data Exchange (ETDEWEB)

    Curiel, M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Palomo, M. J. [ISIRYM, Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain); Urrea, M. [Iberdrola Generacion S. A., Central Nuclear Cofrentes, Carretera Almansa Requena s/n, 04662 Cofrentes, Valencia (Spain); Vaquer, J., E-mail: m.curiel@lainsa.co [TITANIA Servicios Tecnologicos SL, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain)

    2010-10-15

    This paper related to Sipping machine control system new design to perform integrity of nuclear fuel test. This test is a non destructive technique used for evaluating the radiated nuclear fuel coating structural integrity. It is based on the radioactive emission detection of fission elements in the reactor cooling system, using the fuel inspection equipment Sipping. The equipment consists of one simultaneous test bell-shaped vessel of eight fuel elements, and another one for individual element test, a control workstation and some accessories (cables, thermocouples, hoses). Sipping inspection is carried out by means of fuel element vessel. Through air injection, water flows around the element and heat evacuation is reduced, so fuel elements temperature increases. Those elements with faults shall expelled fission components dissolved in water and/or as a gas component. The project aim is the Sipping system control design and software based on LabVIEWTM, for control, monitoring and documentation of the Sipping test. This project shall give a major functionality to the system and, at the same time, shall facilitate the user a friendlier and interactive environment allowing: 1) To substitute the present work platform with a real-time electronic system based on cRIO and a control software ad-hoc designed for Sipping system. 2) To equip new system of a major redundancy for data storage, minimising loss probability of the same. (Author)

  5. Results of testing various natural gas desulfurization adsorbents

    Science.gov (United States)

    Israelson, Gordon

    2004-06-01

    This article presents the results of testing many commercially available and some experimental sulfur adsorbents. The desired result of our testing was to find an effective method to reduce the quantity of sulfur in natural gas to less than 100 ppb volume (0.1 ppm volume). An amount of 100 ppb sulfur is the maximum limit permitted for Siemens Westinghouse solid oxide fuel cells (SOFCs). The tested adsorbents include some that rely only on physical adsorption such as activated carbon, some that rely on chemisorption such as heated zinc oxide, and some that may use both processes. The testing was performed on an engineering scale with beds larger than those used for typical laboratory tests. All tests were done at about 3.45 barg (50 psig). The natural gas used for testing was from the local pipeline in Pittsburgh and averaged 6 ppm volume total sulfur. The primary sulfur species were dimethyl sulfide (DMS), isopropyl mercaptan, tertiary butyl mercaptan, and tetrahydrothiophene. Some tests required several months to achieve a sulfur breakthrough of the bed. It was found that DMS always came through a desulfurizer bed first, independent of adsorption process. Since the breakthrough of DMS always exceeds the 100 ppb SOFC sulfur limit before other sulfurs were detected, an index was created to rate the adsorbents in units of ppm DMS × absorbent bed volume. This index is useful for calculating the expected adsorbent bed lifetime before sulfur breakthrough when the inlet natural gas DMS content is known. The adsorbents that are included in these reports were obtained from suppliers in the United States, the Netherlands, Japan, and England. Three activated carbons from different suppliers were found to have identical performance in removing DMS. One of these activated carbons was operated at four different space velocities and again showed the same performance. When using activated carbon as the basis of comparison for other adsorbents, three high-performance adsorbents

  6. The XRS Low Temperature Cryogenic System: Ground Performance Test Results

    Science.gov (United States)

    Breon, Susan; Sirron, Peter; Boyle, Robert; Canavan, Ed; DiPirro, Michael; Serlemitsos, Aristides; Tuttle, James; Whitehouse, Paul

    1998-01-01

    The X-Ray Spectrometer (XRS) instrument is part of the Astro-E mission scheduled to launch early in 2000. Its cryogenic system is required to cool a 32-element square array of x-ray microcalorimeters to 60-65 mK over a mission lifetime of at least 2 years. This is accomplished using an adiabatic demagnetization refrigerator (ADR) contained within a two-stage superfluid helium/solid neon cooler. Goddard Space Flight Center is providing the ADR and helium dewar. The flight system was assembled in Sept. 1997 and subjected to extensive thermal performance tests. This paper presents test results at both the system and component levels. In addition, results of the low temperature topoff performed in Japan with the engineering unit neon and helium dewars are discussed.

  7. The CLEO-III RICH Detector and Beam Test Results

    CERN Document Server

    Wang, J C; Ayad, R; Azfar, F; Dambasuren, E; Efimov, A; Kopp, S E; Majumder, G; Mountain, R; Schuh, S; Skwarnicki, T; Stone, S; Viehhauser, G; Anderson, S; Smith, A; Kubota, Y; Lipeles, E; Coan, T E; Staeck, J; Fadeev, V; Volobuev, I P

    1999-01-01

    We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the photo-sensitive material, and low-noise Viking readout electronics. Results of a beam test of the first two out of total 30 sectors are presented.

  8. Performance test results for the Eaton dc development power train in an electric test bed vehicle

    Science.gov (United States)

    Crumley, R. L.; Donaldson, M. R.

    1987-09-01

    This report presents the results of the tests performed on a direct current (dc) power train in a test bed vehicle developed by the Eaton Corporation for the U.S. Department of Energy (DOE). The tests were performed by EG and G Idaho, Inc. at the Idaho National Engineering Laboratory (INEL). The purpose of the INEL testing was to provide test results from which an evaluation of the performance capabilities of the Eaton dc power train could be made and compared with other vehicle propulsion systems. The planned tests were primarily oriented toward road testing, chassis dynamometer testing, and associated dynamometer coastdown tests for road loss determination. Range tests of the Eaton dc test bed vehicle using an ALCO 2200 lead acid battery pack, produced ranges of 97 km at 56 km/h (60 miles at 35 mph), 79 km at 72 km/h (49 miles at 45 mph), and 47 km at 88 km/h (29 miles at 55 mph). The corresponding net dc energy consumptions are 135 Wh/km (217 Wh/mile), 145 Wh/km (233 Wh/mile), and 178 Wh/km (287 Wh/mile). The energy consumption for the D-cycle test was 241 Wh/km (387 Wh/mile).

  9. Test results of the optical PAT test bed for satellite laser communications

    Science.gov (United States)

    Sun, Jianfeng; Liu, Liren; Zhou, Yu; Liu, De'an

    2008-08-01

    Satellite laser communication systems offer many advantages such as high data rate, small sized equipment, low consumption electric power and others. Recent successful demonstrations of laser communications have demonstrated the feasibility of some of the key aspects of this technology. Sub-microradian pointing, acquisition, and tracking (PAT) functions are key issue to establish the laser communication system in space. The terminals must perform a series of onground test to evaluate characteristics of The PAT performances before flight test. So an optical dynamical PAT test bed is developed to perform ground test of a laser terminal. In this paper, we detail the separate test and the system test results of the optical dynamical PAT test bed. The test was carried out by auto-collimation method, the precision deflect accuracy, scan accuracy and deflect scan accuracy are obtained.

  10. Seismic II over I Drop Test Program results and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the [open quotes]sources[close quotes] and [open quotes]targets[close quotes] requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources.

  11. Seismic II over I Drop Test Program results and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the {open_quotes}sources{close_quotes} and {open_quotes}targets{close_quotes} requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources.

  12. Small-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, G. N.; Mahoney, Lenna A.; Tran, Diana N.; Burns, Carolyn A.; Kurath, Dean E.

    2013-08-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the

  13. Fan Noise Source Diagnostic Test: Rotor Alone Aerodynamic Performance Results

    Science.gov (United States)

    Hughes, Christopher E.; Jeracki, Robert J.; Woodward, Richard P.; Miller, Christopher J.

    2005-01-01

    The aerodynamic performance of an isolated fan or rotor alone model was measured in the NASA Glenn Research Center 9- by 15- Foot Low Speed Wind Tunnel as part of the Fan Broadband Source Diagnostic Test conducted at NASA Glenn. The Source Diagnostic Test was conducted to identify the noise sources within a wind tunnel scale model of a turbofan engine and quantify their contribution to the overall system noise level. The fan was part of a 1/5th scale model representation of the bypass stage of a current technology turbofan engine. For the rotor alone testing, the fan and nacelle, including the inlet, external cowl, and fixed area fan exit nozzle, were modeled in the test hardware; the internal outlet guide vanes located behind the fan were removed. Without the outlet guide vanes, the velocity at the nozzle exit changes significantly, thereby affecting the fan performance. As part of the investigation, variations in the fan nozzle area were tested in order to match as closely as possible the rotor alone performance with the fan performance obtained with the outlet guide vanes installed. The fan operating performance was determined using fixed pressure/temperature combination rakes and the corrected weight flow. The performance results indicate that a suitable nozzle exit was achieved to be able to closely match the rotor alone and fan/outlet guide vane configuration performance on the sea level operating line. A small shift in the slope of the sea level operating line was measured, which resulted in a slightly higher rotor alone fan pressure ratio at take-off conditions, matched fan performance at cutback conditions, and a slightly lower rotor alone fan pressure ratio at approach conditions. However, the small differences in fan performance at all fan conditions were considered too small to affect the fan acoustic performance.

  14. SCD1 thermal design and test result analysis

    Science.gov (United States)

    Cardoso, Humberto Pontes; Muraoka, Issamu; Mantelli, Marcia Barbosa Henriques; Leite, Rosangela M. G.

    1990-01-01

    The SCD 01 (Satelite de Coleta de Dados 01) is a spin stabilized low Earth orbit satellite dedicated to the collection and distribution of environmental data. It was completely developed at the Brazilian Institute for Space Research (INPE) and is scheduled to be launched in 1992. The SCD 01 passive thermal control design configuration is presented and the thermal analysis results are compared with the temperatures obtained from a Thermal Balance Test. The correlation between the analytical and experimental results is considered very good. Numerical flight simulations show that the thermal control design can keep all the subsystem temperatures within their specified temperature range.

  15. Challenges in interpretation of thyroid hormone test results

    Directory of Open Access Journals (Sweden)

    Lalić Tijana

    2016-01-01

    Full Text Available Introduction. In interpreting thyroid hormones results it is preferable to think of interference and changes in concentration of their carrier proteins. Outline of Cases. We present two patients with discrepancy between the results of thyroid function tests and clinical status. The first case presents a 62-year-old patient with a nodular goiter and Hashimoto thyroiditis. Thyroid function test showed low thyroid-stimulating hormone (TSH and normal to low fT4. By determining thyroid status (ТSH, T4, fT4, T3, fT3 in two laboratories, basal and after dilution, as well as thyroxine-binding globulin (TBG, it was concluded that the thyroid hormone levels were normal. The results were influenced by heterophile antibodies leading to a false lower TSH level and suspected secondary hypothyroidism. The second case, a 40-year-old patient, was examined and followed because of the variable size thyroid nodule and initially borderline elevated TSH, after which thyroid status showed low level of total thyroid hormones and normal TSH. Based on additional analysis it was concluded that low T4 and T3 were a result of low TBG. It is a hereditary genetic disorder with no clinical significance. Conclusion. Erroneous diagnosis of thyroid disorders and potentially harmful treatment could be avoided by proving the interference or TBG deficiency whenever there is a discrepancy between the thyroid function results and the clinical picture.

  16. The Evaluation of Prick Test Results in Malatya

    Directory of Open Access Journals (Sweden)

    Hasan Kahraman

    2014-03-01

    Full Text Available Aim: Skin prick test used for determination of allergic diseases is an easy, cheap, safe, fast, and frequently utilized test. There are factors such as genetic tendency, climate, humidity, vegetation, and altitude affecting the development of allergy. Our goal is to determine the allergic susceptibility of allergic patient in Malatya province. Material and Method: The 403 patients who referred to our chest clinic in Malatya between January 2008 and June 2010 with complaint of respiratory allergic diseases including asthma and allergic rhinitis were retrospectively investigated. Skin prick test results were evaluated according to age and gender. Results: Of the 403 patients incorporated to the study, 177 (43.9% were male, 226 (56.1% were female. Most common reaction was against to grasses, in 78 patients (19.4%. The other common reactions were found against to grains, in 70 patients (17.4%; to D. Farinea in 51 patients (12.7%; to D Pteronyssinus in 44 patients (10.9%; to grass mix in 41 patients (10.2%. Although reactions were higher in men than in women, only against to D. Pteronyssinus was statistical significant (p=0.032. Reactions were observed most commonly in 10-19 age group and secondly in 20-29 age group. Discussion: Atopic patients in Malatya province should be careful especially against to grasses, grains, and house dust mites.

  17. Polynomial Tests of Normal Forms and Some Related Results

    Institute of Scientific and Technical Information of China (English)

    王克

    1992-01-01

    The following problem is called the everywhere-cover problem:“Given a set of dependencies over a database scheme,is he set of dependencies explicitly given for each relation scheme equivalent to the dependencies implied for that relation sheme?”It is shown that when the everywhere-cover problem has a yes answer,examining only the dependencies explicitly given will suffice to test 3NF, BCNF and 4NF of a database scheme.But this does not hold for 2NF.Consequently,in such cases,tests of BCNF and 4NF all take polynomial time.Then a proof is given that test of 3NF of a database scheme is Co-NP-complete,and from this result it is shown that everywhere-cover is also Co-NP-complete when only functional dependencies are allowed.These results lead to doubt the truth of the well believed conjecture that no polynomial time algorithm for designing a lossless BCNF database scheme is likely to exist.

  18. Suit Port Aft Bulkhead Mockup Test Results and Lessons Learned

    Science.gov (United States)

    Romig, Barbara A.; Allton, Charles

    2009-01-01

    The Small Pressurized Rover (SPR) is currently being carried as an integral part of the current Lunar Surface Architectures under consideration in the Constellation program. One element of the SPR is the suit port, the means by which the crew performs Extravehicular Activities (EVAs). Two suit port deliverables were produced in fiscal year 2008: an aft bulkhead mockup for functional integrated testing with the 1-G SPR mockup and a functional and pressurizable engineering unit. This paper focuses on the test results and lessons learned on the aft bulkhead mockup. The suit port aft bulkhead mockup was integrated with the mockup of the SPR cabin and chassis. It is located on the aft bulkhead of the SPR cabin structure and includes hatches, a locking mechanism, seals, interior and exterior suit don/doff aids, and exterior platforms to accommodate different crewmember heights. A lightweight mockup of the Mark III suit was tested with the suit port aft bulkhead mockup. There are several limitations to the suit port and mockup suits, and results of the suit port evaluation are presented and interpreted within the context of the limitations.

  19. High School Staff Characteristics and Mathematics Test Results

    Directory of Open Access Journals (Sweden)

    Mark Fetler

    1999-03-01

    Full Text Available This study investigates the relationship between measures of mathematics teacher skill and student achievement in California high schools. Test scores are analyzed in relation to teacher experience and education and student demographics. The results are consistent with the hypotheses that there is a shortage of qualified mathematics teachers in California and that this shortage is associated with low student scores in mathematics. After controlling for poverty, teacher experience and preparation significantly predict test scores. Short-term strategies to increase the supply of qualified mathematics teachers could include staff development, and recruitment incentives. A long-term strategy addressing root causes of the shortage requires more emphasis on mathematics in high school and undergraduate programs.

  20. Beam Test Results of High Q CBPM prototype for SXFEL

    CERN Document Server

    Chen, Jian; Yu, Luyang; Lai, Longwei; Yuan, Renxian

    2016-01-01

    Aiming at high precision beam position measurement of micron or sub-micron for Shanghai Soft X-ray free electron laser (SXFEL) facility which is being built in site of the Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute of Applied Physics has developed a high Q cavity beam position monitor (CBPM) that the resonant frequency is 4.7 GHz and relevant BPM electronics include dedicated RF front-end and home-made digital BPM (DBPM) also has been done. The cavity design, cold test, system architecture and the beam test with three adjacent pickups has been performed in Shanghai Deep ultraviolet free electron laser(SDUV-FEL) facility are included. The beam experiment results show that the physical design of our CBPM is consistent with the expectations basically and the beam position resolution can fulfill the resolution requirements for the SXFEL project if we optimize the beam conditions.

  1. Preliminary Results of Testing of Flow Effects on Evaporator Scaling

    Energy Technology Data Exchange (ETDEWEB)

    Hu, M.Z.

    2002-02-15

    This investigation has focused on the effects of fluid flow on solids deposition from solutions that simulate the feed to the 2H evaporator at the Savannah River Site. Literature studies indicate that the fluid flow (or shear) affects particle-particle and particle-surface interactions and thus the phenomena of particle aggregation in solution and particle deposition (i.e., scale formation) onto solid surfaces. Experimental tests were conducted with two configurations: (1) using a rheometer to provide controlled shear conditions and (2) using controlled flow of reactive solution through samples of stainless steel tubing. All tests were conducted at 80 C and at high silicon and aluminum concentrations, 0.133 M each, in solutions containing 4 M sodium hydroxide and 1 A4 each of sodium nitrate and sodium nitrite. Two findings from these experiments are important for consideration in developing approaches for reducing or eliminating evaporator scaling problems: (1) The rheometer tests suggested that for the conditions studied, maximum solids deposition occurs at a moderate shear rate, approximately 12 s{sup -1}. That value is expected to be on the order of shear rates that will occur in various parts of the evaporator system; for instance, a 6 gal/min single-phase liquid flow through the 2-in. lift or gravity drain lines would result in a shear rate of approximately 16 s{sup -1}. These results imply that engineering approaches aimed at reducing deposits through increased mixing would need to generate shear near all surfaces significantly greater than 12 s{sup -1}. However, further testing is needed to set a target value for shear that is applicable to evaporator operation. This is because the measured trend is not statistically significant at the 95% confidence interval due to variability in the results. In addition, testing at higher temperatures and lower concentrations of aluminum and silicon would more accurately represent conditions in the evaporator. Without

  2. Test Results of the ALICE SDD Electronic Readout Prototypes

    CERN Document Server

    Mazza, G; Anelli, G; Bonazzola, G C; Cavagnino, D; Cerello, P G; De Remigis, P; Falchieri, D; Gabrielli, A; Gandolfi, E; Giubellino, P; Masetti, M; Montaño-Zetina, L M; Nouais, D; Rivetti, A; Tosello, F; Werbrouck, A E; Wheadon, R

    2000-01-01

    The first prototypes of the front-end electronics of the ALICE silicon driftdetectors have been designed and tested. The integrated circuits have been designed using state of the art technologies and, for the analog parts, with radiation-tolerantdesign techniques. In this paper, the test results of the building blocks of the PASCAL chip and the first prototype of the AMBRA chip are presented. The prototypes fully respect the ALICE requirements; owingto the use of deep-submicron technologies together with radiation-tolerant layout techniques, the prototypes have shown a toleranceto a radiation dose much higher than the one foreseen for the ALICE environment.(Abstract only available, full text to follow).

  3. A new test machine for measuring friction and wear in controlled atmospheres to 1200 C

    Science.gov (United States)

    Sliney, Harold E.; Dellacorte, Christopher

    1991-01-01

    This paper describes a new high-temperature friction and wear test apparatus (tribometer). The tribometer can be used as a pin-on-disk or pin-on-ring configuration and is specially designed to measure the tribological properties of ceramics and high temperature metallic alloys from room temperature to 1200 C. Sliding mode can be selected to be either unidirectional at velocities up to 22 m/sec or oscillating at frequencies up to 4.6 Hz and amplitudes up to + or - 60 deg. The test atmosphere is established by a controlled flow rate of a purge gas. All components within the test chamber are compatible with oxidizing, inert or reducing gases.

  4. Hanford coring bit temperature monitor development testing results report

    Energy Technology Data Exchange (ETDEWEB)

    Rey, D.

    1995-05-01

    Instrumentation which directly monitors the temperature of a coring bit used to retrieve core samples of high level nuclear waste stored in tanks at Hanford was developed at Sandia National Laboratories. Monitoring the temperature of the coring bit is desired to enhance the safety of the coring operations. A unique application of mature technologies was used to accomplish the measurement. This report documents the results of development testing performed at Sandia to assure the instrumentation will withstand the severe environments present in the waste tanks.

  5. Preliminary operational results of the industrial process heat field tests

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.; Davenport, R.

    1980-04-01

    There are currently six DOE-funded solar industrial process heat (IPH) field tests which have been operational for one year or longer. These are all low temperature first generation projects which supply heat at temperatures below 100/sup 0/C - three hot water and three hot air. During the 1979 calendar year, personnel from the Solar Energy Research Institute (SERI) visited all of these sites; the performance and cost results obtained for each project and the operational problems encountered at each site are discussed.

  6. Advanced stellar compass deep space navigation, ground testing results

    DEFF Research Database (Denmark)

    Betto, Maurizio; Jørgensen, John Leif; Jørgensen, Peter Siegbjørn

    2006-01-01

    Deep space exploration is in the agenda of the major space agencies worldwide and at least the European Space Agency (SMART & Aurora Programs) and the American NASA (New Millennium Program) have set up programs to allow the development and the demonstration of technologies that can reduce the ris...... to determine the orbit of a spacecraft autonomously, on-board and without any a priori knowledge of any kind. The solution is robust, elegant and fast. This paper presents the preliminary performances obtained during the ground tests. The results are very positive and encouraging....

  7. Using Large Scale Test Results for Pedagogical Purposes

    DEFF Research Database (Denmark)

    Dolin, Jens

    2012-01-01

    The use and influence of large scale tests (LST), both national and international, has increased dramatically within the last decade. This process has revealed a tension between the legitimate need for information about the performance of the educational system and teachers to inform policy...... wash back effects known from other research but gave additionally some insight in teachers’ attitudes towards LSTs. To account for these findings results from another research project - the Validation of PISA – will be included. This project analyzed how PISA has influenced the Danish educational...

  8. The NOE scintillating fiber calorimeter prototype test results

    CERN Document Server

    Alexandrov, K V; Bernardini, P; Brigida, M; Campana, D; Candela, A M; Caruso, R; Cassese, F; Ceres, A; D'Aquino, B; De Cataldo, G; De Mitri, I; Di Credico, A; Favuzzi, C; Fusco, P; Gargano, F; Giglietto, N; Giordano, F; Grillo, A; Guarino, F; Gustavino, C; Lamanna, E; Lauro, A; Leone, A; Loparco, F; Mancarella, G; Martello, D; Mazziotta, M N; Mikheyev, S P; Mongelli, M; Osteria, G; Palladino, Vittorio; Passeggio, G; Perchiazzi, M; Pontoniere, G; Rainó, A; Rocco, R; Romanucci, E; Rubizzo, U; Sacchetti, A; Scapparone, E; Spinelli, P; Tikhomirov, V; Vaccina, A; Vanzanella, E; Weber, M

    2001-01-01

    An intense R&D program has been carried out by the NOE collaboration during the last years, to develop a massive fine grain scintillating fiber calorimeter, to be used, in combination with an appropriate target, in a long base line experiment at the CERN to Gran Sasso (CNGS) neutrino beam. The performance of a 4 ton NOE calorimeter prototype exposed to a test beam at CERN PS is shown. Results on the linearity, electromagnetic and hadronic energy resolution are reported and compared with the Monte Carlo predictions. (13 refs).

  9. The ethical significance of diagnostic test results in psychology practice.

    Science.gov (United States)

    Shefler, Gaby; Ben Shakhar, Gershon; Bilu, Yoram

    2009-03-01

    "Psychologists base the opinions contained in their recommendations, reports and diagnostic or evaluative statements including forensic testimony on information and techniques sufficient to substantiate their findings". Do expert psychodiagnosticians rely in their professional final reports on the materials and raw data obtained from test materials? How ethical are they in their professional performances? In order to answer this question, expert clinical psychologists were given batteries of psychodiagnostic tests, accompanied by one of two different types of background information, suggesting either a Borderline Personality Disorder, or a Paranoid Personality Disorder. This background information was a full and strongly suggestive story in one experiment, and a mere hypothesis in another. All conditions manifested a confirmation bias: the psychodiagnostic reports were profoundly biased by the background suggestions. The present paper focuses on a content analysis of the reports, and shows that the experts referred very little if at all to the psychodiagnostic materials they received. They were found less professional and as a result- less ethical. The ethical relevance of these findings to the teaching and training of professional psychodiagnosticians is discussed, with an emphasis on the importance of teaching students and interns in clinical psychology to base their diagnostic reports on the test data.

  10. Test Results for LHC Insertion Region Dipole Magnets

    CERN Document Server

    Muratore, Joseph F; Cozzolino, John P; Ganetis, George; Ghosh, Arup; Gupta, Ramesh C; Harrison, Michael; Kumar-Jain, Animesh; Marone, Andrew; Richard-Plate, Stephen; Schmalzle, Jesse D; Thomas, Richard A; Wanderer, Peter; Willen, Erich; Wu, Kuo-Chen

    2005-01-01

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They produce fields up to 3.8 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, which have the most challenging design. In these, the dipole fields in both apertures point in the same direction, unlike LHC arc dipoles. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality. Magnetic field measurements were done at 4.5K and at room temperature, and warm-...

  11. Tc-99 Adsorption on Selected Activated Carbons - Batch Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Wellman, Dawn M.; Golovich, Elizabeth C.; Cordova, Elsa A.; Smith, Ronald M.

    2010-12-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently developing a 200-West Area groundwater pump-and-treat system as the remedial action selected under the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision for Operable Unit (OU) 200-ZP-1. This report documents the results of treatability tests Pacific Northwest National Laboratory researchers conducted to quantify the ability of selected activated carbon products (or carbons) to adsorb technetium-99 (Tc-99) from 200-West Area groundwater. The Tc-99 adsorption performance of seven activated carbons (J177601 Calgon Fitrasorb 400, J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, J177612 Norit GAC830, J177613 Norit GAC830, and J177617 Nucon LW1230) were evaluated using water from well 299-W19-36. Four of the best performing carbons (J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, and J177613 Norit GAC830) were selected for batch isotherm testing. The batch isotherm tests on four of the selected carbons indicated that under lower nitrate concentration conditions (382 mg/L), Kd values ranged from 6,000 to 20,000 mL/g. In comparison. Under higher nitrate (750 mg/L) conditions, there was a measureable decrease in Tc-99 adsorption with Kd values ranging from 3,000 to 7,000 mL/g. The adsorption data fit both the Langmuir and the Freundlich equations. Supplemental tests were conducted using the two carbons that demonstrated the highest adsorption capacity to resolve the issue of the best fit isotherm. These tests indicated that Langmuir isotherms provided the best fit for Tc-99 adsorption under low nitrate concentration conditions. At the design basis concentration of Tc 0.865 µg/L(14,700 pCi/L), the predicted Kd values from using Langmuir isotherm constants were 5,980 mL/g and 6,870 mL/g for for the two carbons. These Kd values did not meet the target Kd value of 9,000 mL/g. Tests

  12. Operational Results of a Closed Brayton Cycle Test-Loop

    Science.gov (United States)

    Wright, Steven A.; Fuller, Robert; Lipinski, Ronald J.; Nichols, Kenneth; Brown, Nicholas

    2005-02-01

    A number of space and terrestrial power system designs plan to use nuclear reactors that are coupled to Closed-loop Brayton Cycle (CBC) systems to generate electrical power. Because very little experience exists regarding the operational behavior of these systems, Sandia National Laboratories (through its Laboratory Directed Research and Development program) is developing a closed-loop test bed that can be used to determine the operational behavior of these systems and to validate models for these systems. Sandia has contracted Barber-Nichols Corporation to design, fabricate, and assemble a Closed-loop Brayton Cycle (CBC) system. This system was developed by modifying commercially available hardware. It uses a 30 kWe Capstone C-30 gas-turbine unit (www.capstoneturbine.com) with a modified housing that permits the attachment of an electrical heater and a water cooled chiller that are connected to the turbo-machinery in a closed loop. The test-loop reuses the Capstone turbine, compressor, and alternator. The Capstone system's nominal operating point is 1150 K turbine inlet temperature at 96,000 rpm. The annular recuperator and portions of the Capstone control system (inverter) and starter system are also reused. The rotational speed of the turbo-machinery is controlled either by adjusting the alternator load by either using the electrical grid or a separate load bank. This report describes the test-loop hardware SBL-30 (Sandia Brayton Loop-30kWe). Also presented are results of early testing and modeling of the unit. The SBL-30 hardware is currently configured with a heater that is limited to 80 kWth with a maximum outlet temperature of ˜1000 K.

  13. Flight Test 4 Preliminary Results: NASA Ames SSI

    Science.gov (United States)

    Isaacson, Doug; Gong, Chester; Reardon, Scott; Santiago, Confesor

    2016-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements as well as the safety substantiation and end-to-end assessment of DAA system performance. The Unmanned Aircraft System (UAS) Integration into the National Airspace System (NAS) Project conducted flight test program, referred to as Flight Test 4, at Armstrong Flight Research Center from April -June 2016. Part of the test flights were dedicated to the NASA Ames-developed Detect and Avoid (DAA) System referred to as JADEM (Java Architecture for DAA Extensibility and Modeling). The encounter scenarios, which involved NASA's Ikhana UAS and a manned intruder aircraft, were designed to collect data on DAA system performance in real-world conditions and uncertainties with four different surveillance sensor systems. Flight test 4 has four objectives: (1) validate DAA requirements in stressing cases that drive MOPS requirements, including: high-speed cooperative intruder, low-speed non-cooperative intruder, high vertical closure rate encounter, and Mode CS-only intruder (i.e. without ADS-B), (2) validate TCASDAA alerting and guidance interoperability concept in the presence of realistic sensor, tracking and navigational errors and in multiple-intruder encounters against both cooperative and non-cooperative intruders, (3) validate Well Clear Recovery guidance in the presence of realistic sensor, tracking and navigational errors, and (4) validate DAA alerting and guidance requirements in the presence of realistic sensor, tracking and navigational errors. The results will be

  14. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  15. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  16. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  17. Using a "time machine" to test for local adaptation of aquatic microbes to temporal and spatial environmental variation.

    Science.gov (United States)

    Fox, Jeremy W; Harder, Lawrence D

    2015-01-01

    Local adaptation occurs when different environments are dominated by different specialist genotypes, each of which is relatively fit in its local conditions and relatively unfit under other conditions. Analogously, ecological species sorting occurs when different environments are dominated by different competing species, each of which is relatively fit in its local conditions. The simplest theory predicts that spatial, but not temporal, environmental variation selects for local adaptation (or generates species sorting), but this prediction is difficult to test. Although organisms can be reciprocally transplanted among sites, doing so among times seems implausible. Here, we describe a reciprocal transplant experiment testing for local adaptation or species sorting of lake bacteria in response to both temporal and spatial variation in water chemistry. The experiment used a -80°C freezer as a "time machine." Bacterial isolates and water samples were frozen for later use, allowing transplantation of older isolates "forward in time" and newer isolates "backward in time." Surprisingly, local maladaptation predominated over local adaptation in both space and time. Such local maladaptation may indicate that adaptation, or the analogous species sorting process, fails to keep pace with temporal fluctuations in water chemistry. This hypothesis could be tested with more finely resolved temporal data.

  18. Re-Design and Beat Testing of the Man-Machine Integration Design and Analysis System: MIDAS

    Science.gov (United States)

    Shively, R. Jay; Rutkowski, Michael (Technical Monitor)

    1999-01-01

    The Man-machine Design and Analysis System (MIDAS) is a human factors design and analysis system that combines human cognitive models with 3D CAD models and rapid prototyping and simulation techniques. MIDAS allows designers to ask 'what if' types of questions early in concept exploration and development prior to actual hardware development. The system outputs predictions of operator workload, situational awareness and system performance as well as graphical visualization of the cockpit designs interacting with models of the human in a mission scenario. Recently, MIDAS was re-designed to enhance functionality and usability. The goals driving the redesign include more efficient processing, GUI interface, advances in the memory structures, implementation of external vision models and audition. These changes were detailed in an earlier paper. Two Beta test sites with diverse applications have been chosen. One Beta test site is investigating the development of a new airframe and its interaction with the air traffic management system. The second Beta test effort will investigate 3D auditory cueing in conjunction with traditional visual cueing strategies including panel-mounted and heads-up displays. The progress and lessons learned on each of these projects will be discussed.

  19. Aerodynamic and Acoustic Flight Test Results and Results for the Stratospheric Observatory for Infrared Astronomy

    Science.gov (United States)

    Cumming, Stephen B.; Smith, Mark S.; Cliatt, Larry J.; Frederick, Michael A.

    2014-01-01

    As part of the Stratospheric Observatory for Infrared Astronomy program, a 747SP airplane was modified to carry a 2.5-m telescope in the aft section of the fuselage. The resulting airborne observatory allows for observations above 99 percent of the water vapor in the atmosphere. The open cavity created by the modifications had the potential to significantly affect the airplane in the areas of aerodynamics and acoustics. Several series of flight tests were conducted to clear the operating envelope of the airplane for astronomical observations, planned to be performed between the altitudes of 35,000 ft and 45,000 ft. The flight tests were successfully completed. Cavity acoustics were below design limits, and the overall acoustic characteristics of the cavity were better than expected. The modification did have some effects on the stability and control of the airplane, but these effects were not significant. Airplane air data systems were not affected by the modifications. This paper describes the methods used to examine the aerodynamics and acoustic data from the flight tests and provides a discussion of the flight-test results in the areas of cavity acoustics, stability and control, and air data.

  20. Test results of high-precision large cryogenic lens holders

    Science.gov (United States)

    Gal, C.; Reutlinger, A.; Boesz, A.; Leberle, T.; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2012-09-01

    For the Euclid mission a Pre-Development phase is implemented to prove feasibility of individual components of the system [1]. The Near Infrared Spectrometer and Photometer (NISP) of EUCLID requires high precision large lens holders (?170 mm) at cryogenic temperatures (150K). The four lenses of the optical system are made of different materials: fused silica, CaF2, and LF5G15 that are mounted in a separate lens barrel design. Each lens has its separate mechanical interface to the lens barrel, the so called adaption ring. The performance of the lens holder design is verified by adapted test equipment and test facility including an optical metrology system. The characterization of the lens deformation and displacement (decenter, tilt) due to mechanical loads of the holder itself as well as thermally induced loads are driven by the required submicron precision range and the operational thermal condition. The surface deformation of the lens and its holder is verified by interferometric measurements, while tilt and position accuracy are measured by in-situ fibre based distance sensors. The selected distance measurement sensors have the capability to measure in a few mm range with submicron resolution in ultra high vacuum, in vibration environments and at liquid nitrogen temperatures and below. The calibration of the measurement system is of crucial importance: impacts such as temperature fluctuation, surface roughness, surface reflectivity, straylight effects, etc. on the measured distance are carefully calibrated. Inbuilt thermal expansion effects of the fibre sensors are characterized and proven with lens dummy with quasi zero CTE. The paper presents the test results and measured performance of the high precision large cryogenic lens holders attained by the metrology system. These results are presented on behalf of the EUCLID consortium.

  1. Comparison of FEA Calculations with Cryostat Dummy Weight Test Results

    CERN Document Server

    Guarino, V

    2004-01-01

    Extensive Finite Element analyses were performed to determine the loads and stresses acting on the EB and Barrel during assembly and in its final configuration. Up to now it has been difficult to verify the FEA results due to the unusual compression at the inner radius shims has resulted in larger than anticipated deflections. The cryostat dummy load test offers the first real chance for a direct comparison between the deflections of the Tilecal and the FEA model. By comparing the difference in position of the FM's before the cryostat load was applied and afterwards it is possible to eliminate all other variables and compare directly with the FEA model. This paper will present a comparison between the FEA model and the survey measurements for when the cryostat dummy weight load was applied at 32 modules and 46 modules in place.

  2. JWST tunable filter imager: etalon prototype test results

    Science.gov (United States)

    Touahri, D.; Cameron, P.; Evans, C.; Greenberg, E.; Rowlands, N.; Scott, A.; Doyon, R.; Beaulieu, M.; Djazovski, O.

    2008-07-01

    We present the prototyping results and laboratory characterization of a narrow band Fabry-Perot etalon flight model which is one of the wavelength selecting elements of the Tunable Filter Imager. The latter is a part of the Fine Guidance Sensor which represents the Canadian contribution to NASA's James Webb Space Telescope. The unique design of this etalon provides the JWST observatory with the ability to image at 30 Kelvin, a 2.2'x2.2' portion of its field of view in a narrow spectral bandwidth of R~100 at any wavelength ranging between 1.6 and 4.9 μm (with a gap in coverage between 2.5 and 3.2 μm). Extensive testing has resulted in better understanding of the thermal properties of the piezoelectric transducers used as an actuation system for the etalon gap tuning. Good throughput, spectral resolution and contrast have been demonstrated for the full wavelength range.

  3. TMED-4 INTERIM REPORT PURE ZR EQUILIBRIUM TEST RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Korinko, P.; Morgan, G.

    2010-12-17

    Due to higher than expected permeation rates in the production of tritium in the TVA, a development and testing program was implemented to develop the understanding of why the higher rates were occurring. In addition, improved data are needed for both the design as well as the predictive models. One part of the program was to determine the equilibrium pressure of hydrogen and tritium over NPZ (1). During the course of this testing, some curious results were discovered (2) compared to the published literature data (3). Due to these apparently results, a follow-on task was undertaken to determine the equilibrium pressure of protium and deuterium over pure zirconium. A series of experiments were conducted to determine equilibrium pressures and isotherm data for the zirconium - protium and zirconium - deuterium systems. The data match the published literature data reasonably well with the plateau extending to loadings of about 1.4. There is a significant pressure rise for loadings greater than 1.7.

  4. Fan Noise Source Diagnostic Test: LDV Measured Flow Field Results

    Science.gov (United States)

    Podboy, Gary C.; Krupar, Martin J.; Hughes, Christopher E.; Woodward, Richard P.

    2003-01-01

    Results are presented of an experiment conducted to investigate potential sources of noise in the flow developed by two 22-in. diameter turbofan models. The R4 and M5 rotors that were tested were designed to operate at nominal take-off speeds of 12,657 and 14,064 RPMC, respectively. Both fans were tested with a common set of swept stators installed downstream of the rotors. Detailed measurements of the flows generated by the two were made using a laser Doppler velocimeter system. The wake flows generated by the two rotors are illustrated through a series of contour plots. These show that the two wake flows are quite different, especially in the tip region. These data are used to explain some of the differences in the rotor/stator interaction noise generated by the two fan stages. In addition to these wake data, measurements were also made in the R4 rotor blade passages. These results illustrate the tip flow development within the blade passages, its migration downstream, and (at high rotor speeds) its merging with the blade wake of the adjacent (following) blade. Data also depict the variation of this tip flow with tip clearance. Data obtained within the rotor blade passages at high rotational speeds illustrate the variation of the mean shock position across the different blade passages.

  5. Results of the mole penetration tests in different materials

    Science.gov (United States)

    Wawrzaszek, Roman; Seweryn, Karol; Grygorczuk, Jerzy; Banaszkiewicz, Marek; Rybus, Tomasz; Wisniewski, Lukasz; Neal, Clive R.; Huang, Shaopeng

    2010-05-01

    . Influence of the material compaction on the mole progress was also investigated. For these tests the small testbed has been used. It allowed us to test our mole penetrator up to the depth of 0.5 meters. Obtained results show that 'KRET' is able to penetrate even compacted lunar regolith simulant CHENOBI with minimum progress rate about 2mm per stroke. Moreover, we have confirmed that the mole works properly in both materials with low and high cohesion.

  6. First Test Results of the bERLinPro 2-cell Booster Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Burrill, Andrew [Helmholtz-Zentrum Berlin (HZB), (Germany); Anders, W. [Helmholtz-Zentrum Berlin (HZB), (Germany); Frahm, A. [Helmholtz-Zentrum Berlin (HZB), (Germany); Knobloch, Jens [Helmholtz-Zentrum Berlin (HZB), (Germany); Neumann, Axel [Helmholtz-Zentrum Berlin (HZB), (Germany); Ciovati, Gianluigi [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Clemens, William [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Kneisel, Peter [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Turlington, Larry [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2015-09-01

    The bERLinPro Energy Recovery Linac (ERL) is currently being built at Helmholtz-Zentrum Berlin in order to study the physics of operating a high-current, a 100 mA, 50 MeV ERL utilizing all SRF cavity technology. This machine will utilize three unique SRF cryomodules for the photoinjector, booster and linac cryomodules respectively. The focus of this paper will be on the cavities contained within the booster cryomodule. Here there will be three 2-cell SRF cavities, based on the original design by Cornell University, but optimized to meet the needs of the project. All of the cavity fabrication, processing and testing was carried out at Jefferson Laboratory, where 4 cavities were produced, and the 3 cavities with the best RF performance were fitted with helium vessels for installation in the cryomodule. This paper will report on the test results of the cavities as measured in the vertical testing dewar at JLab after fabrication and again after outfitting with the helium vessels.

  7. Field Test Results from a 10 kW Wind Turbine with Active Flow Control

    Science.gov (United States)

    Rice, Thomas; Bychkova, Veronika; Taylor, Keith; Clingman, Dan; Amitay, Michael

    2015-11-01

    Active flow control devices including synthetic jets and dynamic vortex generators were tested on a 10 kW wind turbine at RPI. Previous work has shown that load oscillations caused by dynamic stall could be modified through the use of active flow control by injecting momentum into the flow field near the leading edge of a dynamically pitching model. In this study, this work has been extended to its logical conclusion, field-testing active flow control on a real wind turbine. The blades in the current study have a 0.28m chord and 3.05m span, no twist or taper, and were retrofitted with six synthetic jets on one blade and ten dynamic vortex generators on a second blade. The third blade of this turbine was not modified, in order to serve as a control. Strain gauges were installed on each blade to measure blades' deflection. A simple closed loop control was demonstrated and preliminary results indicate reduced vibrational amplitude. Future testing will be conducted on a larger scale, 600kW machine at NREL, incorporating information collected during this study.

  8. School results and access test results as indicators of first-year performance at university

    Directory of Open Access Journals (Sweden)

    A Bothma

    2004-06-01

    Full Text Available The goals set by the National Plan for Higher Education, the fact that many schools are still severely disadvantaged as well as far-reaching changes in the school system demand that South African universities urgently reconsider their admission procedures. Redesigning admission procedures calls for a thorough understanding of the interrelationships between school marks, results in existing access tests and first-year university performance. These interrelationships were statistically investigated in the case of the 1999, 2000 and 2001 intake groups, who were compelled to write access tests before being admitted to Stellenbosch University. The results of this investigation confirm an alarming degree of unpreparedness among many prospective students regarding what is expected of them at university. This is aggravated by school marks creating a totally unrealistic expectation of performance in the first year at university. It is emphasised that schools and authorities dealing with admission of prospective students at universities should be cognisant of the findings reported here. Furthermore, the statistical analyses demonstrate several novel techniques for investigating the interrelationship between school marks, access test results and university performance.

  9. Results of industrial tests of carbonate additive to fuel oil

    Science.gov (United States)

    Zvereva, E. R.; Dmitriev, A. V.; Shageev, M. F.; Akhmetvalieva, G. R.

    2017-08-01

    Fuel oil plays an important role in the energy balance of our country. The quality of fuel oil significantly affects the conditions of its transport, storage, and combustion; release of contaminants to atmosphere; and the operation of main and auxiliary facilities of HPPs. According to the Energy Strategy of Russia for the Period until 2030, the oil-refining ratio gradually increases; as a result, the fraction of straight-run fuel oil in heavy fuel oils consistently decreases, which leads to the worsening of performance characteristics of fuel oil. Consequently, the problem of the increase in the quality of residual fuel oil is quite topical. In this paper, it is suggested to treat fuel oil by additives during its combustion, which would provide the improvement of ecological and economic indicators of oil-fired HPPs. Advantages of this method include simplicity of implementation, low energy and capital expenses, and the possibility to use production waste as additives. In the paper, the results are presented of industrial tests of the combustion of fuel oil with the additive of dewatered carbonate sludge, which is formed during coagulation and lime treatment of environmental waters on HPPs. The design of a volume delivery device is developed for the steady additive input to the boiler air duct. The values are given for the main parameters of the condition of a TGM-84B boiler plant. The mechanism of action of dewatered carbonate sludge on sulfur oxides, which are formed during fuel oil combustion, is considered. Results of industrial tests indicate the decrease in the mass fraction of discharged sulfur oxides by 36.5%. Evaluation of the prevented damage from sulfur oxide discharged into atmospheric air shows that the combustion of the fuel oil of 100 brand using carbonate sludge as an additive (0.1 wt %) saves nearly 6 million rubles a year during environmental actions at the consumption of fuel oil of 138240 t/year.

  10. Polygraph Test Results Assessment by Regression Analysis Methods

    Directory of Open Access Journals (Sweden)

    K. A. Leontiev

    2014-01-01

    Full Text Available The paper considers a problem of defining the importance of asked questions for the examinee under judicial and psychophysiological polygraph examination by methods of mathematical statistics. It offers the classification algorithm based on the logistic regression as an optimum Bayesian classifier, considering weight coefficients of information for the polygraph-recorded physiological parameters with no condition for independence of the measured signs.Actually, binary classification is executed by results of polygraph examination with preliminary normalization and standardization of primary results, with check of a hypothesis that distribution of obtained data is normal, as well as with calculation of coefficients of linear regression between input values and responses by method of maximum likelihood. Further, the logistic curve divided signs into two classes of the "significant" and "insignificant" type.Efficiency of model is estimated by means of the ROC analysis (Receiver Operator Characteristics. It is shown that necessary minimum sample has to contain results of 45 measurements at least. This approach ensures a reliable result provided that an expert-polygraphologist possesses sufficient qualification and follows testing techniques.

  11. Test Results and Comparison of Triaxial Strength Testing of Waste Isolation Pilot Plant Clean Salt

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Stuart A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined, the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.

  12. ELEFUNT test results under NS32000 Fortran V2. 5. 3 on the Sequent Balance. [Sequent Balance

    Energy Technology Data Exchange (ETDEWEB)

    Cody, W.J.

    1986-09-01

    In January 1986 a Sequent Balance Computer was installed in the Mathematics and Computer Science Division's Advanced Computing Research Facility (ACRF). In July 1986 the system consisted of 4 processors sharing 8 megabytes of memory. This paper summarizes and analyzes the results of running various programs designed to test the arithmetic and the Fortran elementary and intrinsic function packages on that machine. The programs run include MACHAR and the ELEFUNT suite of transportable Fortran test programs from the Software Manual for the Elementary Functions by Cody and Waite (1980), the Fortran version of the arithmetic test program PARANOIA )Karpinski, 1985), and prototype programs from the nascent INTFUNT test suite for intrinsic functions. All tests were run using NS32000 Fortran V2.5.3 under the DYNIX V2.0.1 operating system (based on 4.2 BSD UNIX. 8 refs., 4 tabs.

  13. Fission Surface Power Technology Demonstration Unit Test Results

    Science.gov (United States)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

  14. MATISSE: alignment, integration, and test phase first results

    Science.gov (United States)

    Allouche, F.; Robbe-Dubois, S.; Lagarde, S.; Cruzalèbes, P.; Antonelli, P.; Bresson, Y.; Fantei-Caujolle, Y.; Marcotto, A.; Morel, S.; Beckmann, U.; Bettonvil, F.; Berio, Ph.; Heininger, M.; Lehmitz, M.; Agocs, T.; Brast, R.; Elswijk, E.; Ives, D.; Meixner, K.; Laun, W.; Mellein, M.; Neumann, U.; Bailet, C.; Clausse, J.-M.; Matter, A.; Meilland, A.; Millour, F.; Petrov, R. G.; Accardo, M.; Bristow, P.; Frahm, R.; Glindemann, A.; Gonzáles Herrera, J.-C.; Lizon, J.-L.; Schöller, M.; Graser, U.; Jaffe, W.; Lopez, B.

    2016-08-01

    MATISSE (Multi AperTure mid-Infrared SpectroScopic Experiment) is the spectro-interferometer for the VLTI of the European Southern Observatory, operating in near and mid-infrared, and combining up to four beams from the unit or the auxiliary telescopes. MATISSE will offer new breakthroughs in the study of circumstellar environments by allowing the multispectral mapping of the material distribution, the gas and essentially the dust. The instrument consists in a warm optical system (WOP) accepting four optical beams and relaying them after a dichroic splitting (for the L and M- and N- spectral bands) to cold optical benches (COB) located in two separate cryostats. The Observatoire de la Côte d'Azur is in charge of the WOP providing the spectral band separation, optical path equalization and modulation, pupil positioning, beam anamorphosis, beam commutation, and calibration. NOVA-ASTRON is in charge of the COB providing the functions of beam selection, reduction of thermal background emission, spatial filtering, pupil transfer, photometry and interferometry splitting, additional beam anamorphosis, spectral filtering, polarization selection, image dispersion, and image combination. The Max Planck Institut für Radio Astronomie is in charge of the operation and performance validation of the two detectors, a HAWAII-2RG from Teledyne for the L- and M- bands and a Raytheon AQUARIUS for the N-band. Both detectors are provided by ESO. The Max Planck Institut für Astronomie is in charge of the electronics and the cryostats for which the requirements on space limitations and vibration stability resulted on very specific and stringent decisions on the design. The integration and test of the COB: the two cryogenic systems, including the cold benches and the detectors, have been conducted at MPIA in parallel with the integration of the WOP at OCA. At the end of 2014, the complete instrument was integrated at OCA. Following this integration, a period of interface and alignment

  15. Surrogate/spent fuel sabotage : aerosol ratio test program and Phase 2 test results.

    Energy Technology Data Exchange (ETDEWEB)

    Borek, Theodore Thaddeus III; Thompson, N. Slater (U.S. Department of Energy); Sorenson, Ken Bryce; Hibbs, R.S. (U.S. Department of Energy); Nolte, Oliver (Fraunhofer Institut fur Toxikologie und Experimentelle Medizin, Germany); Molecke, Martin Alan; Autrusson, Bruno (Institut de Radioprotection et de Surete Nucleaire, France); Young, F. I. (U.S. Nuclear Regulatory Commission); Koch, Wolfgang (Fraunhofer Institut fur Toxikologie und Experimentelle Medizin, Germany); Brochard, Didier (Institut de Radioprotection et de Surete Nucleaire, France); Pretzsch, Gunter Guido (Gesellschaft fur Anlagen- und Reaktorsicherheit, Germany); Lange, Florentin (Gesellschaft fur Anlagen- und Reaktorsicherheit, Germany)

    2004-05-01

    A multinational test program is in progress to quantify the aerosol particulates produced when a high energy density device, HEDD, impacts surrogate material and actual spent fuel test rodlets. This program provides needed data that are relevant to some sabotage scenarios in relation to spent fuel transport and storage casks, and associated risk assessments; the program also provides significant political benefits in international cooperation. We are quantifying the spent fuel ratio, SFR, the ratio of the aerosol particles released from HEDD-impacted actual spent fuel to the aerosol particles produced from surrogate materials, measured under closely matched test conditions. In addition, we are measuring the amounts, nuclide content, size distribution of the released aerosol materials, and enhanced sorption of volatile fission product nuclides onto specific aerosol particle size fractions. These data are crucial for predicting radiological impacts. This document includes a thorough description of the test program, including the current, detailed test plan, concept and design, plus a description of all test components, and requirements for future components and related nuclear facility needs. It also serves as a program status report as of the end of FY 2003. All available test results, observations, and analyses - primarily for surrogate material Phase 2 tests using cerium oxide sintered ceramic pellets are included. This spent fuel sabotage - aerosol test program is coordinated with the international Working Group for Sabotage Concerns of Transport and Storage Casks, WGSTSC, and supported by both the U.S. Department of Energy and Nuclear Regulatory Commission.

  16. Recent Radiation Test Results for Trench Power MOSFETs

    Science.gov (United States)

    Lauenstein, Jean-Marie; Casey, Megan C.; Wilcox, Edward P.; Phan, Anthony M.; Kim, Hak S.; Topper, Alyson D.; Ladbury, Raymond L.; Label, Kenneth A.

    2017-01-01

    Single-event effect (SEE) radiation test results are presented for various trench-gate power MOSFETs. The heavy-ion response of the first (and only) radiation-hardened trench-gate power MOSFET is evaluated: the manufacturer SEE response curve is verified and importantly, no localized dosing effects are measured, distinguishing it from other, non-hardened trench-gate power MOSFETs. Evaluations are made of n-type commercial and both n- and p-type automotive grade trench-gate device using ions comparable to of those on the low linear energy transfer (LET) side of the iron knee of the galactic cosmic ray spectrum, to explore suitability of these parts for missions with higher risk tolerance and shorter duration, such as CubeSats. Part-to-part variability of SEE threshold suggests testing with larger sample sizes and applying more aggressive derating to avoid on-orbit failures. The n-type devices yielded expected localized dosing effects including when irradiated in an unbiased (0-V) configuration, adding to the challenge of inserting these parts into space flight missions.

  17. 2011 Hyundai Sonata 3539 - Hybrid Electric Vehicle Battery Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Matthew Shirk; Tyler Gray; Jeffrey Wishart

    2014-09-01

    The U.S. Department of Energy’s Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles, including testing hybrid electric vehicle batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on-road fleet testing. This report documents battery testing performed for the 2011 Hyundai Sonata Hybrid (VIN KMHEC4A47BA003539). Battery testing was performed by Intertek Testing Services NA. The Idaho National Laboratory and Intertek collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Program of the U.S. Department of Energy.

  18. Drop Test Results of CRDM under Seismic Loads

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Kim, Gyeong-Ho; Sun, Jong-Oh; Huh, Hyung [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    This paper describes the test results to demonstrate the drop performance of CRDM under seismic loads. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the drop performance under seismic loads such as operating basis earthquake (OBE) and safe shutdown earthquake (SSE). Especially, the CAR drop times are important data for the safety analysis. confirm the drop performance under seismic loads. The delay of drop time at Rig no. 2 due to seismic loads is greater than that at Rig no. 3. The total pure drop times under seismic loads are estimated as 1.169 and 1.855, respectively.

  19. Results of MPBX studies at the single heater test

    Energy Technology Data Exchange (ETDEWEB)

    Blair, S. C.,LLNL

    1997-10-01

    We have developed an extensometer for measurement of distance and displacements in a geologic repository for high-level nuclear waste. This is an optical extensometer that measures distance using a modulated laser beam. In this design, reflecting targets are placed at desired measurement locations, and distance between each target and an optical head are measured repeatedly using the modulated laser beam. Moreover, all electronic and moving parts are located outside of the hostile or difficult environment as the optical head is connected to the laser, switching and signal analysis hardware using optical fibers. A reference beam is utilized to provide direct correction of system behavior. `Be system also - utilizes movable reflective anchors that can be repositioned if desired. We have installed the system in the Single Heater Test being conducted in Alcove 5 of the Exploratory Studies Facility at Yucca Mountain, and report preliminary results.

  20. Results from the Exoplanet Search Programmes with BEST and TEST

    CERN Document Server

    Eislöffel, J; Rauer, H; Voss, H; Erikson, A; Eigmueller, P; Günther, E; Eisloeffel, Jochen; Hatzes, Artie P.; Rauer, Heike; Voss, Holger; Erikson, Anders; Eigmueller, Philipp; Guenther, Eike

    2006-01-01

    Thueringer Landessternwarte Tautenburg (TLS) has started to operate a small dedicated telescope - the Tautenburg Exoplanet Search Telescope (TEST) - searching for transits of extrasolar planets in photometric time series observations. In a joint effort with the Berlin Exoplanet Search Telescope (BEST) operated by the Institut fuer Planetenforschung of the "Deutsches Zentrum fuer Luft- und Raumfahrt (DLR)" at the Observatoire de Haute-Provence (OHP), France, two observing sites are used to optimise transit search. Here, we give a short overview of these systems and the data analysis. We describe a software pipeline that we have set up to identify transit events of extrasolar planets and variable stars in time series data from these and other telescopes, and report on some first results.

  1. Nonlinear Analysis and Preliminary Testing Results of a Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.; Wu, Hsi-Yung T.

    2015-01-01

    A large test article was recently designed, analyzed, fabricated, and successfully tested up to the representative design ultimate loads to demonstrate that stiffened composite panels with through-the-thickness reinforcement are a viable option for the next generation large transport category aircraft, including non-conventional configurations such as the hybrid wing body. This paper focuses on finite element analysis and test data correlation of the hybrid wing body center section test article under mechanical, pressure and combined load conditions. Good agreement between predictive nonlinear finite element analysis and test data is found. Results indicate that a geometrically nonlinear analysis is needed to accurately capture the behavior of the non-circular pressurized and highly-stressed structure when the design approach permits local buckling.

  2. Acoustic conditions in open plan offices – Pilot test results

    Directory of Open Access Journals (Sweden)

    Witold Mikulski

    2016-10-01

    Full Text Available Background: The main source of noise in open plan office are conversations. Office work standards in such premises are attained by applying specific acoustic adaptation. This article presents the results of pilot tests and acoustic evaluation of open space rooms. Material and Methods: Acoustic properties of 6 open plan office rooms were the subject of the tests. Evaluation parameters, measurement methods and criterial values were adopted according to the following standards: PN-EN ISO 3382- 3:2012, PN-EN ISO 3382-2:2010, PN-B-02151-4:2015-06 and PN-B-02151-3:2015-10. Results: The reverberation time was 0.33– 0.55 s (maximum permissible value in offices – 0.6 s; the criterion was met, sound absorption coefficient in relation to 1 m2 of the room’s plan was 0.77–1.58 m2 (minimum permissible value – 1.1 m2; 2 out of 6 rooms met the criterion, distraction distance was 8.5–14 m (maximum permissible value – 5 m; none of the rooms met the criterion, A-weighted sound pressure level of speech at a distance of 4 m was 43.8–54.7 dB (maximum permissible value – 48 dB; 2 out of 6 rooms met the criterion, spatial decay rate of the speech was 1.8–6.3 dB (minimum permissible value – 7 dB; none of the rooms met the criterion. Conclusions: Standard acoustic treatment, containing sound absorbing suspended ceiling, sound absorbing materials on the walls, carpet flooring and sound absorbing workplace barriers, is not sufficient. These rooms require specific advanced acoustic solutions. Med Pr 2016;67(5:653–662

  3. Enhanced vision systems: results of simulation and operational tests

    Science.gov (United States)

    Hecker, Peter; Doehler, Hans-Ullrich

    1998-07-01

    Today's aircrews have to handle more and more complex situations. Most critical tasks in the field of civil aviation are landing approaches and taxiing. Especially under bad weather conditions the crew has to handle a tremendous workload. Therefore DLR's Institute of Flight Guidance has developed a concept for an enhanced vision system (EVS), which increases performance and safety of the aircrew and provides comprehensive situational awareness. In previous contributions some elements of this concept have been presented, i.e. the 'Simulation of Imaging Radar for Obstacle Detection and Enhanced Vision' by Doehler and Bollmeyer 1996. Now the presented paper gives an overview about the DLR's enhanced vision concept and research approach, which consists of two main components: simulation and experimental evaluation. In a first step the simulational environment for enhanced vision research with a pilot-in-the-loop is introduced. An existing fixed base flight simulator is supplemented by real-time simulations of imaging sensors, i.e. imaging radar and infrared. By applying methods of data fusion an enhanced vision display is generated combining different levels of information, such as terrain model data, processed images acquired by sensors, aircraft state vectors and data transmitted via datalink. The second part of this contribution presents some experimental results. In cooperation with Daimler Benz Aerospace Sensorsystems Ulm, a test van and a test aircraft were equipped with a prototype of an imaging millimeter wave radar. This sophisticated HiVision Radar is up to now one of the most promising sensors for all weather operations. Images acquired by this sensor are shown as well as results of data fusion processes based on digital terrain models. The contribution is concluded by a short video presentation.

  4. Results of Thyroid Function Tests in Premature Infants

    Directory of Open Access Journals (Sweden)

    Pelin Doğan

    2016-04-01

    Full Text Available Introduction: To determine the rate, etiology and morbidity association of disorders of thyroid function tests (TFTs in premature babies. Materials and Methods: A total of 139 premature babies who were admitted to Uludag University Faculty of Medicine Hospital Neonatal Intensive Care Unit between January 2009 and January 2012 were included in this study. Prenatal, natal and postnatal characteristics along with TFTs results were recorded. TFTs were performed for all patients in the first and third weeks of life. Thyroid stimulation hormone (TSH values of >10 IU/L was considered elevated. Free T3 and T4 levels were evaluated according to laboratory cut-off values. Weight, height and head circumference values of all individuals with and without the diagnosis of hypothyroidism on the 6th, 12th, and 18th months of their polyclinic follow-ups.Results: Abnormal TFTs were detected in 41 (24% patients. Twenty two patients (53% had transient TSH elevation, 9 (22% had primary hypothyroidism, 9 (22% had non-thyroidal disease and 1 (2.4% had transient hypothyroxinemia. Among morbidities, respiratory distress syndrome rate was found to be significantly higher in patients with thyroid function disorders (p=0.007. The rate of thyroid function disorders in patients with mothers with hypothyroidism was significantly more frequent compared to patients without maternal hypothyroidism (p=0.049. The mean head circumference in 18 month was significantly lower in patients with abnormal TFTs (p=0.047. Conclusions: Thyroid function disorders are common morbidities in premature babies and are important for neuromotor development. Maternal thyroid function disorder can lead to impairment of TFTs in infants. Thyroid function tests should be performed in all premature babies and hypotyhroidism should be treated. Avoidance of iodine exposure in premature infants can reduce the rate of abnormal TFTs and transient hypothyroidism.

  5. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Pilot-Scale Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Gary M. Blythe

    2006-03-01

    - Pilot Additive Testing in Texas Lignite Flue Gas; Task 3 - Full-scale FGD Additive Testing in High Sulfur Eastern Bituminous Flue Gas; Task 4 - Pilot Wet Scrubber Additive Tests at Yates; and Task 5 - Full-scale Additive Tests at Plant Yates. This topical report presents the results from the Task 2 and Task 4 pilot-scale additive tests. The Task 3 and Task 5 full-scale additive tests will be conducted later in calendar year 2006.

  6. Small-scale experimental tests of tandem mirror machines with thermal barriers

    Energy Technology Data Exchange (ETDEWEB)

    Drake, R.P.

    1979-09-01

    A summary is given of current physical understanding of tandem mirrors with thermal barriers. Physicists who understand tandem mirrors can use this document as a preliminary guide to the physical issues and experimental problems involved. This report will focus upon the issues that can be tested experimentally, and on the areas needing experimental and theoretical inventions. The next section discusses the plasma potentials and plasma confinement which correspond to a tandem mirror with thermal barriers, assuming the barriers exist in steady-state. The creation of a barrier is discussed, i.e., the natural tendency of the barrier cell to fill with plasma must be countered by pumping ions out of the barrier. The design of a barrier-pumping experiment for TMX is described.

  7. Results of Detailed Hydrologic Characterization Tests - Fiscal Year 2000

    Energy Technology Data Exchange (ETDEWEB)

    Spane, Frank A.; Thorne, Paul D.; Newcomer, Darrell R.

    2001-05-15

    This report provides the resluts of detailed hydrologic characterization tests conducted within eleven Hanford Site wells during fiscal year 2000. Detailed characterization tests performed included groundwater-flow characterization; barometric response evaluation; slug tests; single-well tracer tests; constant-rate pumping tests; and in-well, vertical flow tests. Hydraulic property estimates obtained from the detailed hydrologic tests include transmissivity; hydraulic conductivity; specific yield; effective porosity; in-well, lateral flow velocity; aquifer-flow velocity; vertical distribution of hydraulic conductivity (within the well-screen section); and in-well, verticla flow velocity. In addition, local groundwater-flow characteristics (i.e., hydraulic gradient and flow direction) were determined for four sites where detailed well testing was performed.

  8. A blast absorber test: measurement and model results

    NARCIS (Netherlands)

    Eerden, F.J.M. van der; Berg, F. van den; Hof, J. van 't; Arkel, E. van

    2006-01-01

    A blast absorber test was conducted at the Aberdeen Test Centre from 13 to 17 June 2005. The test was set up to determine the absorbing and shielding effect of a gravel pile, of 1.5 meters high and 15 by 15 meters wide, on blasts from large weapons: e.g. armor, artillery or demolition. The blast was

  9. Pre-course Results from the Astronomy Diagnostic Test

    Science.gov (United States)

    Hufnagel, Beth; Slater, Timothy; Deming, Grace; Adams, Jeff; Adrian, Rebecca L.; Brick, Christine; Zeilik, Michael

    2000-08-01

    We present selected results from the January 1999 semester pre-course administration of the Astronomy Diagnostic Test (ADT), a research-based, multiple-choice instrument that assesses student knowledge and understanding about selected concepts in astronomy. The ADT is valid for undergraduate non-science majors taking an introductory astronomy course. This paper briefly summarises the development and validation processes, which included pre-course administration to 1557 students in 22 classes attending 17 various post-secondary institutions across the USA in the January 1999 semester. Two interesting results of the ADT's pre-course administration are (1) the average class score of the ADT is about the same (32%) regardless of type of post-secondary institution or class size and (2) there is a significant gender difference, with women scoring an average of 28% and men 38%, with the standard errors both less than 1%. The current version of the ADT (Version 2 dated 21 June 1999) and a comparative by-class database is available to astronomy instructors at the (USA) Association of Astronomy Educators' and the National Institute for Science Education's (NISE) WebPages.

  10. Preliminary results of processing of Pulkovo series of photographic observations of double star 61 Cygni measured by automatic machine "Fantasy"

    Science.gov (United States)

    Gorshanov, D. L.; Shakht, N. A.; Kisselev, A. A.; Polyakov, E. V.; Bronnikova, A. A.; Kanaev, I. I.

    2003-11-01

    Two long-term series of photographic observations of one of the nearest double star 61 Cygni have been obtained at Pulkovo by means of normal astrograph in 1895-2000 (I) and by means of 26'' refractor in 1958-2000 (II). All these observations have been measured by means automatic machine "Fantasy" with mean error of yearly positions 0.016'' and 0.008'' for I and II series correspondly. The periodic deviations with period 6.4 +/- 0.5 yr in the residuals in relative distances between components are noticed for series II.

  11. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  12. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  13. Augmented dry cooling surface test program: analysis and experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Parry, H.L.; MacGowan, L.J.; Kreid, D.K.; Wiles, L.E.; Faletti, D.W.; Johnson, B.M.

    1979-09-01

    Experiments were performed to assess the operating characteristics and potential performance of water-augmented dry cooling systems. The work was aimed at evaluating a deluged air-cooled HOETERV plate fin heat exchanger surface proposed for integrated dry/wet cooling systems and using test results to guide the development of a predictive analytical model. In the process, all-dry performance data were obtained for the HOETERV surface as well as for two Curtiss-Wright chipped fin surfaces. The dry heat transfer data indicate that a slotted Curtiss-Wright surface slightly outperforms the HOETERV and nonslotted Curtiss-Wright surfaces based on heat rejection rate per unit of fan power. However, all three surfaces are so close in performance that other factors, such as surface cost and piping and mounting costs, will probably determine which surface is preferred at a given installation. Comparisons of deluged HOETERV performance with dry HOETERV and Curtiss-Wright performance under prototypic conditions have established that deluging can provide considerable heat rejection enhancement, particularly at low ITD and low air humidity. A deluged HOETERV core operating at a 115/sup 0/F primary fluid temperature in 105/sup 0/F air at 10% relative humidity can reject over 7 times as much heat as a dry HOETERV core operating under the same conditions at the same air-side pressure drop. Deluged tests were performed to evaluate the effect of airflow rate, deluge flow rate and core tilt angle on performance. Both increased airflow and increased deluge flow increase both heat rejection rate and required fan power. Optimal airflow rate will thus be determined for a given location by the competing costs of heat exchanger surface area versus fan operation. Changes in core tilt angle from vertical to 16/sup 0/ from vertical have a negligible effect on performance.

  14. Results of Q Disease Tests With 350-MHz Spoke Cavities

    Science.gov (United States)

    Tajima, Tsuyoshi; Edwards, Randy L.; Krawczyk, Frank L.; Liu, Jian-Fei; Schrage, Dale L.; Shapiro, Alan H.

    2003-07-01

    Spoke cavities have been developed at LANL for an accelerator-driven nuclear waste transmutation system. One of the most important issues for this development is how we can build and operate the accelerator at minimum costs. It would save a significant amount of money if we do not need to heat treat the cavity at high temperatures to avoid Q disease. This motivated us to check to see if Q disease occurs with 350-MHz spoke cavities. We have tested 3 cavities, ANL, LANL/EZ02 and LANL/EZ01 so far. The ANL cavity was made of RRR˜150 and the LANL cavities were made of RRR˜250 niobium. The ANL cavity was chemically polished 98 microns at LANL with a standard buffered chemical polishing (BCP) solution, i.e., HF:HNO3:H3PO4=1:1:2 by volume, at 14 - 18 °C. We did not see any Q degradation after holding the cavity at 100 - 102 K for 13 hours or at 100 - 142 K for 86 hours. This cavity was unintentionally baked at >200 °C under poor vacuum, which may have caused thicker oxide layer that prevent the Q disease from occurring as well as due to lower RRR. The LANL/EZ02 and LANL/EZ01 cavities were polished 150 microns with standard BCP solution at <15 °C. The LANL/EZ02 cavity showed a ˜50 % Q degradation after holding the cavity at 100 - 132 K for 61 hours. More systematic tests with LANL/EZ01 to determine the dangerous temperature range precisely are under way by changing the holding temperature every 10 K. The detail of the results will be presented here.

  15. 立式加工中心主轴动态误差的测试及研究%Test and research of vertical machine center's dynamic errors

    Institute of Scientific and Technical Information of China (English)

    刘阔; 王冠明; 马晓波

    2013-01-01

    The reason of principal spindle's dynamic errors is analyzed. Principal spindle's radial average errors and asynchronous errors, axial average errors and asynchronous errors, minimum radial separation center of some vertical machine center are all tested by SPN-300 of API. The three test results of principal spindle's dynamic errors in different rotating speeds are presented. The test results are analyzed at last.%首先对主轴动态误差产生的原因进行了分析,采用API的SPN-300主轴动态误差分析仪对某立式加工中心的主轴径向平均误差和异步误差、轴向平均误差和异步误差、主轴最小径向间距等进行了测试,给出了主轴动态误差在不同转速下的3次测试结果;最后对测试结果进行了分析.

  16. 2011 Hyundai Sonata 4932 - Hybrid Electric Vehicle Battery Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Tyler Gray; Matthew Shirk; Jeffrey Wishart

    2013-07-01

    The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on-road fleet testing. This report documents battery testing performed for the 2011 Hyundai Sonata Hybrid HEV (VIN KMHEC4A43BA004932). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the AVTA for the Vehicle Technologies Program of the DOE.

  17. In-vitro tensile testing machine for vibration study of fresh rabbit Achilles tendon

    Science.gov (United States)

    Revel, Gian M.; Scalise, Alessandro; Scalise, Lorenzo; Pianosi, Antonella

    2001-10-01

    A lot of people, overall athletic one suffer from tendinitis or complete rupture of the Achilles tendon. This structure becomes inflamed and damaged mainly from a variety of mechanical forces and sometimes due to metabolic problems, such as diabetes or arthritis. Over the past three decades extensive studies have been performed on the structural and mechanical properties of Achilles tendon trying to explain the constitutive equations to describe and foresee tendon behavior. Among the various mechanical parameters, the vibrational behavior is also of interest. Several investigations are performed in order to study how the Achilles tendon vibrations influence the response of the muscle proprioception and human posture. The present article describes how in vitro tensile experiments can be performed, taking into account the need to simulate physiological condition of Achilles tendon and thus approaching some opened problems in the design of the experimental set-up. A new system for evaluating tendon vibrations by non contact techniques is proposed. Preliminary simple elongation tests are made extracting the main mechanical parameters: stress and strain at different fixed stretches, in order to characterize the tissue. Finally, a vibration study is made at each pretensioned tendon level evaluating the oscillating curves caused by a small hammer.

  18. Tests of composite materials at cryogenic temperatures facilities and results

    CERN Document Server

    Dahlerup-Petersen, K

    1980-01-01

    The design and installation of test facilities for the determination of macromechanical and thermal properties of fiber-reinforced polymer materials at temperatures down to 4.2K are presented. Construction and performance details are given for the following test equipment: quasi- static-tensile and compression-test facilities equipped with an automatic data acquisition system for calculation of material properties, deformation characteristics and various statistics; a thermal contraction-expansion measuring system; a thermal conductivity measurement cell. (1 refs).

  19. Students’ ability in science: Results from a test development study

    Directory of Open Access Journals (Sweden)

    Cigdem Akkanat

    2017-03-01

    Full Text Available Student’s ability to use and manipulate scientific concepts has been widely explored; however there is still a need to define the characteristics and nature of science ability. Also, the tests and performance scales that require minimal conceptual knowledge to measure this ability are relatively less common. The aim of this study was to develop an objective measure of science ability of gifted middle school students. In order to assess this ability, Science Ability Test Battery was developed by the researchers. The test battery was divided into two sub scales containing; a multiple choice questions achievement test (Science Ability Test and a performance assessment (Science Performance Test. The initial Science Ability Test consisted of 23 multiple choice items with one correct answer that required students to use science process skills and reasoning. In the study, stratified sampling was used. The test was administered to 280 middle school students in Turkey and the missing data from 26 students were excluded. In order to obtain a proof of content validity, the researchers elicited feedback from five experts in the field of science education and gifted education and necessary corrections were made in accordance of their views and suggestions. This study will be followed by another research to further analyse validity and reliability of the test.

  20. Behaviour of ceria nanoparticles in standardized test media - influence on the results of ecotoxicological tests

    Energy Technology Data Exchange (ETDEWEB)

    Manier, Nicolas; Garaud, Mael; Delalain, Patrice; Aguerre-Chariol, Olivier; Pandard, Pascal, E-mail: nicolas.manier@ineris.fr [INERIS, Parc technologique ALATA, BP2, 60550 Verneuil en Halatte (France)

    2011-07-06

    The main objectives of this work were to establish the behaviour of a ceria nanopowder in different ecotoxicological media commonly used in standardized aquatic ecotoxicity tests and consequently to assess the acute and chronic ecotoxicity in two micro-invertebrates: Daphnia magna and Ceriodaphnia dubia and in a freshwater green algae: Pseudokirchneriella subcapitata. Different approaches to disperse the ceria nanoparticles (i.e. stirring, use of probe sonication, addition of humic acids) were tested and the influence on the biological endpoints was investigated. Despite the agglomeration phenomena observed in all the tested media, the results obtained indicated higher stability in the lower ionic strength media with addition of humic acid (2 mg.L{sup -1} TOC). No acute toxicity were observed with D. magna, whatever the dispersal method performed and the nCeO{sub 2} concentration tested (up to 1000 mg.L{sup -1}), as no acute toxicity was recorded with C. dubia following exposure to the stirring suspensions. On contrary, acute toxicity was recorded in C. dubia with EC{sub 50} values comprise between 11.9 and 25.3 mg.L{sup -1} using the probe sonicated suspension with or without humic acids addition. Significant chronic effect on the reproduction capability was also recorded in C. dubia. The estimated EC{sub 10} values were comprised between 2.1 and 2.9 mg.L{sup -1}. Focusing on P. subcapitata, despite the different agglomerate size recorded in the tested media at the end of the exposure periods, results obtained were similar. Adverse effect on algal growth around 5 mg.L{sup -1} were reported (mean EC{sub 10} = 4 {+-} 1.8 mg.L{sup -1}). Those results suggested the needed for standardized testing protocol concerning the aqueous media used or the sample preparation for laboratory testing.

  1. [Human basophil degranulation test. Results of a modified technic (I)].

    Science.gov (United States)

    Román Pérez, F; Berlanga Cortés, J A; Urquiă, M; Guerra Pasadas, F; Peña Martínez, J

    1986-01-01

    The degranulation of human basophils towards antigenic substances, to which they must be previously sensitized as a result of the antigen-antibody union at the membrane level, is a phenomenon that has an important application complementing diagnosis of diseases mediated by the Gell and Coombs classification of Type I Hypersensitivity, on which the principle of Human Basophils Degranulation Test (HBDT) was based. An essential requirement is to be able to collect an adequate quantity of basophils, as well as the visualization by means of a technique of convenient stain. In this work, we show a modified HBDT technique for basophil granulocytes staining. A total of 33 HBDT was carried out on patients sensitive to grass pollen and/or Olea europea pollen and/or D. pteronyssinus, and as controls, HBDT was done on healthy individuals with negative clinical history. Basophil enrichemnt from the circulating blood sample was done by means of centrifugation in Percoll density gradients of 1072, 1076, 1080 and 1082, and we obtained a higher number of basophils with a density of 1080 at 400 Xg for 30 minutes. The cellular bottom was resuspended in 600 microliters of PBS. We employed lyophilized antigenic extracts from grass pollen, Olea europea and D. pteronyssinus, employing weight/volume concentration of 10(-4), 10(-5), 10(-6) and 10(-7). The optimum dilutions were 10(-5) for grass pollen and D. pteronyssinus.

  2. Fan Noise Source Diagnostic Test: Vane Unsteady Pressure Results

    Science.gov (United States)

    Envia, Edmane

    2002-01-01

    To investigate the nature of fan outlet guide vane pressure fluctuations and their link to rotor-stator interaction noise, time histories of vane fluctuating pressures were digitally acquired as part of the Fan Noise Source Diagnostic Test. Vane unsteady pressures were measured at seven fan tip speeds for both a radial and a swept vane configuration. Using time-domain averaging and spectral analysis, the blade passing frequency (BPF) harmonic and broadband contents of the vane pressures were individually analyzed. Significant Sound Pressure Level (SPL) reductions were observed for the swept vane relative to the radial vane for the BPF harmonics of vane pressure, but vane broadband reductions due to sweep turned out to be much smaller especially on an average basis. Cross-correlation analysis was used to establish the level of spatial coherence of broadband pressures between different locations on the vane and integral length scales of pressure fluctuations were estimated from these correlations. Two main results of this work are: (1) the average broadband level on the vane (in dB) increases linearly with the fan tip speed for both the radial and swept vanes, and (2) the broadband pressure distribution on the vane is nearly homogeneous and its integral length scale is a monotonically decreasing function of fan tip speed.

  3. Airborne Turbulence Detection and Warning ACLAIM Flight Test Results

    Science.gov (United States)

    Hannon, Stephen M.; Bagley, Hal R.; Soreide, Dave C.; Bowdle, David A.; Bogue, Rodney K.; Ehernberger, L. Jack

    1999-01-01

    The Airborne Coherent Lidar for Advanced Inflight Measurements (ACLAIM) is a NASA/Dryden-lead program to develop and demonstrate a 2 micrometers pulsed Doppler lidar for airborne look-ahead turbulence detection and warning. Advanced warning of approaching turbulence can significantly reduce injuries to passengers and crew aboard commercial airliners. The ACLAIM instrument is a key asset to the ongoing Turbulence component of NASA's Aviation Safety Program, aimed at reducing the accident rate aboard commercial airliners by a factor of five over the next ten years and by a factor of ten over the next twenty years. As well, the advanced turbulence warning capability can prevent "unstarts" in the inlet of supersonic aircraft engines by alerting the flight control computer which then adjusts the engine to operate in a less fuel efficient, and more turbulence tolerant, mode. Initial flight tests of the ACLAIM were completed in March and April of 1998. This paper and presentation gives results from these initial flights, with validated demonstration of Doppler lidar wind turbulence detection several kilometers ahead of the aircraft.

  4. Results and Analysis from Space Suit Joint Torque Testing

    Science.gov (United States)

    Matty, Jennifer E.; Aitchison, Lindsay

    2009-01-01

    A space suit s mobility is critical to an astronaut s ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. The term mobility, with respect to space suits, is defined in terms of two key components: joint range of motion and joint torque. Individually these measures describe the path which in which a joint travels and the force required to move it through that path. Previous space suits mobility requirements were defined as the collective result of these two measures and verified by the completion of discrete functional tasks. While a valid way to impose mobility requirements, such a method does necessitate a solid understanding of the operational scenarios in which the final suit will be performing. Because the Constellation space suit system requirements are being finalized with a relatively immature concept of operations, the Space Suit Element team elected to define mobility in terms of its constituent parts to increase the likelihood that the future pressure garment will be mobile enough to enable a broad scope of undefined exploration activities. The range of motion requirements were defined by measuring the ranges of motion test subjects achieved while performing a series of joint maximizing tasks in a variety of flight and prototype space suits. The definition of joint torque requirements has proved more elusive. NASA evaluated several different approaches to the problem before deciding to generate requirements based on unmanned joint torque evaluations of six different space suit configurations being articulated through 16 separate joint movements. This paper discusses the experiment design, data analysis and results, and the process used to determine the final values for the Constellation pressure garment joint torque requirements.

  5. A non-verbal Turing test: differentiating mind from machine in gaze-based social interaction.

    Science.gov (United States)

    Pfeiffer, Ulrich J; Timmermans, Bert; Bente, Gary; Vogeley, Kai; Schilbach, Leonhard

    2011-01-01

    In social interaction, gaze behavior provides important signals that have a significant impact on our perception of others. Previous investigations, however, have relied on paradigms in which participants are passive observers of other persons' gazes and do not adjust their gaze behavior as is the case in real-life social encounters. We used an interactive eye-tracking paradigm that allows participants to interact with an anthropomorphic virtual character whose gaze behavior is responsive to where the participant looks on the stimulus screen in real time. The character's gaze reactions were systematically varied along a continuum from a maximal probability of gaze aversion to a maximal probability of gaze-following during brief interactions, thereby varying contingency and congruency of the reactions. We investigated how these variations influenced whether participants believed that the character was controlled by another person (i.e., a confederate) or a computer program. In a series of experiments, the human confederate was either introduced as naïve to the task, cooperative, or competitive. Results demonstrate that the ascription of humanness increases with higher congruency of gaze reactions when participants are interacting with a naïve partner. In contrast, humanness ascription is driven by the degree of contingency irrespective of congruency when the confederate was introduced as cooperative. Conversely, during interaction with a competitive confederate, judgments were neither based on congruency nor on contingency. These results offer important insights into what renders the experience of an interaction truly social: Humans appear to have a default expectation of reciprocation that can be influenced drastically by the presumed disposition of the interactor to either cooperate or compete.

  6. A non-verbal Turing test: differentiating mind from machine in gaze-based social interaction.

    Directory of Open Access Journals (Sweden)

    Ulrich J Pfeiffer

    Full Text Available In social interaction, gaze behavior provides important signals that have a significant impact on our perception of others. Previous investigations, however, have relied on paradigms in which participants are passive observers of other persons' gazes and do not adjust their gaze behavior as is the case in real-life social encounters. We used an interactive eye-tracking paradigm that allows participants to interact with an anthropomorphic virtual character whose gaze behavior is responsive to where the participant looks on the stimulus screen in real time. The character's gaze reactions were systematically varied along a continuum from a maximal probability of gaze aversion to a maximal probability of gaze-following during brief interactions, thereby varying contingency and congruency of the reactions. We investigated how these variations influenced whether participants believed that the character was controlled by another person (i.e., a confederate or a computer program. In a series of experiments, the human confederate was either introduced as naïve to the task, cooperative, or competitive. Results demonstrate that the ascription of humanness increases with higher congruency of gaze reactions when participants are interacting with a naïve partner. In contrast, humanness ascription is driven by the degree of contingency irrespective of congruency when the confederate was introduced as cooperative. Conversely, during interaction with a competitive confederate, judgments were neither based on congruency nor on contingency. These results offer important insights into what renders the experience of an interaction truly social: Humans appear to have a default expectation of reciprocation that can be influenced drastically by the presumed disposition of the interactor to either cooperate or compete.

  7. A Non-Verbal Turing Test: Differentiating Mind from Machine in Gaze-Based Social Interaction

    Science.gov (United States)

    Pfeiffer, Ulrich J.; Timmermans, Bert; Bente, Gary; Vogeley, Kai; Schilbach, Leonhard

    2011-01-01

    In social interaction, gaze behavior provides important signals that have a significant impact on our perception of others. Previous investigations, however, have relied on paradigms in which participants are passive observers of other persons’ gazes and do not adjust their gaze behavior as is the case in real-life social encounters. We used an interactive eye-tracking paradigm that allows participants to interact with an anthropomorphic virtual character whose gaze behavior is responsive to where the participant looks on the stimulus screen in real time. The character’s gaze reactions were systematically varied along a continuum from a maximal probability of gaze aversion to a maximal probability of gaze-following during brief interactions, thereby varying contingency and congruency of the reactions. We investigated how these variations influenced whether participants believed that the character was controlled by another person (i.e., a confederate) or a computer program. In a series of experiments, the human confederate was either introduced as naïve to the task, cooperative, or competitive. Results demonstrate that the ascription of humanness increases with higher congruency of gaze reactions when participants are interacting with a naïve partner. In contrast, humanness ascription is driven by the degree of contingency irrespective of congruency when the confederate was introduced as cooperative. Conversely, during interaction with a competitive confederate, judgments were neither based on congruency nor on contingency. These results offer important insights into what renders the experience of an interaction truly social: Humans appear to have a default expectation of reciprocation that can be influenced drastically by the presumed disposition of the interactor to either cooperate or compete. PMID:22096599

  8. Cone Penetrometer Load Cell Temperature and Radiation Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2013-08-28

    This report summarizes testing activities performed at the Pacific Northwest National Laboratory to verify the cone penetrometer load cell can withstand the tank conditions present in 241-AN-101 and 241-AN-106. The tests demonstrated the load cell device will operate under the elevated temperature and radiation levels expected to be encountered during tank farm deployment of the device.

  9. Formative use of test results: A user’s perspective

    NARCIS (Netherlands)

    Hopster-den Otter, Dorien; Hopster-den Otter, Dorien; Wools, S.; Eggen, Theodorus Johannes Hendrikus Maria; Veldkamp, Bernard P.

    2017-01-01

    Despite the potential of using test data to support student learning, several studies have concluded that the actual use of test data remains limited. The present study addresses this problem by examining (1) the types of actions for which teachers, internal coaches, principals and parents within pr

  10. Test results of chemical reactivity test (CRT) analysis of structural materials and explosives

    Energy Technology Data Exchange (ETDEWEB)

    Back, P.S.; Barnhart, B.V.; Walters, R.R.; Haws, L.D.; Collins, L.W.

    1980-03-21

    The chemical reactivity test, CRT, is a procedure used to screen the compatibility of component structure materials with explosives. This report contains the results of CRT materials evaluations conducted at Mound Facility. Data about materials combinations are catalogued both under the name of the explosive and the nonexplosive.

  11. Analysis and testing research on dynamic properties of machine tools based on joints parameters%基于结合面参数的整机动态特性分析与试验研究

    Institute of Scientific and Technical Information of China (English)

    郭成龙; 袁军堂; 李奎; 翁德凯; 陈展翼

    2012-01-01

    Since the joint surface properties of the machine tools influences the performance of the machine tools greatly,modal analysis of vertical milling machine tool AVCP1200H was carried out utilizing ANSYS based on the finite element models of rigid connection and flexible connection of the joints.Then the analyzing tests for two finite element models were verified to be identical through modal test to the machine.In addition the reasons of test error occurred were analyzed and optimization for the model was sug-gested, which provided a reference for studying dynamics of the machine tools as well as digital design and manufacturing.The test results show that: the modal analysis for flexible connection of the joints was in good agreement with the hammering test results with 3 order more errors being within 20%,which dynamic characteristic parameters were proven to impact the performance of the machine significantly.%机床结合面特性对其整体性能具有很大影响,利用ANSYS软件分别对立式数控铣床AVCP1200H结合面刚性联接、柔性联接的有限元模型进行模态分析,然后通过整机模态试验验证两种有限元模型的分析吻合,并对试验误差产生的原因进行分析,提出了优化模型的建议,为该型机床动力学研究及数字化设计制造提供了参考.试验结果表明:结合面柔性联接的模态分析与锤击试验结果较为吻合,3阶以上的误差均在20%以内,证明结合面处的动态特性参数对机床性能有很大影响.

  12. Characterization of machining quality attributes based on spindle probe, coordinate measuring machine, and surface roughness data

    Directory of Open Access Journals (Sweden)

    Tzu-Liang Bill Tseng

    2014-04-01

    Full Text Available This study investigates the effects of machining parameters as they relate to the quality characteristics of machined features. Two most important quality characteristics are set as the dimensional accuracy and the surface roughness. Before any newly acquired machine tool is put to use for production, it is important to test the machine in a systematic way to find out how different parameter settings affect machining quality. The empirical verification was made by conducting a Design of Experiment (DOE with 3 levels and 3 factors on a state-of-the-art Cincinnati Hawk Arrow 750 Vertical Machining Center (VMC. Data analysis revealed that the significant factor was the Hardness of the material and the significant interaction effect was the Hardness + Feed for dimensional accuracy, while the significant factor was Speed for surface roughness. Since the equally important thing is the capability of the instruments from which the quality characteristics are being measured, a comparison was made between the VMC touch probe readings and the measurements from a Mitutoyo coordinate measuring machine (CMM on bore diameters. A machine mounted touch probe has gained a wide acceptance in recent years, as it is more suitable for the modern manufacturing environment. The data vindicated that the VMC touch probe has the capability that is suitable for the production environment. The test results can be incorporated in the process plan to help maintain the machining quality in the subsequent runs.

  13. Results of a 1462 hour ammonia arcjet endurance test

    Science.gov (United States)

    Polk, J. E.; Goodfellow, K. D.

    1992-07-01

    A total of 1462 hours of operaton were demonstrated in an endurance test of a 30 kWe-class ammonia arcjet operated at 10 kWe. The propellant flow rate was 0.170 g/s, and the measured performance increased from approximately 650 s specific impulse at 36 percent efficiency at the beginning of the test to 675 s at 39 percent near the end. The voltage increased and the current dropped slightly over the first 400 hours, and then remained approximately constant for the remainder of the test. The test, scheduled for 1500 hours, was terminated after an insulator in the rear of the engine failed. Post-test examination of the electrodes revealed only minimal damage. Although there was evidence of a number of mass transport processes occurring in the discharge chamber, the primary life-limiting wear mechanisms appear to be cathode tip erosion and constrictor melting.

  14. Can clinical colour vision tests be used to predict the results of the Farnsworth lantern test?

    Science.gov (United States)

    Cole, B L; Maddocks, J D

    1998-11-01

    Clinicians usually do not have access to a lantern test when making an occupational assessment of the ability of a person with defective colour vision to recognise signal light colours: they must rely on the results of ordinary clinical tests. While all colour vision defectives fail the Holmes Wright Type B lantern test and most fail the Holmes Wright Type A lantern, 35% of colour vision defectives pass the Farnsworth lantern. Can clinical tests predict who will pass and fail the Farnsworth lantern? We find that a pass (less than two or more diametrical crossings) at the Farnsworth Panel D 15 Dichotomous test has a sensitivity of 0.67 and specificity of 0.94 in predicting a pass or fail at the Farnsworth lantern test: a Nagel range of > 10 has a sensitivity of 0.87 and a specificity of 0.57. We conclude that neither the D 15 nor the Nagel Anomaloscope matching range are satisfactory predictors of performance on the Farnsworth Lantern.

  15. Preliminary test results from the CELSS Test Facility Engineering Development Unit

    Science.gov (United States)

    Kliss, Mark H.; Macelroy, R. D.; Blackwell, C. C.; Borchers, B. A.; Drews, M. E.; Longabaugh, J. R.; Yendler, B. S.; Zografos, A. I.

    1994-01-01

    As part of the NASA Controlled Ecological Life Support System (CELSS) Program, a CELSS Test Facility (CTF) is being planned for installation on the Space Station. The CTF will be used to provide data on the productivity and efficiency of a variety of CELSS higher plant crops grown in the microgravity environment of the Space Station. Tight environmental control will be maintained while data on gas exchange rates and biomass accumulation rates are collected. In order to obtain an early realistic determination of the subsystem and system requirements necessary to provide the environmental conditions specified for CTF crop productivity experiments, an Engineering Development Unit (EDU) has been designed, constructed and is in the process of subsystem and system testing at NASA Ames Research Center. The EDU is a ground test-bed which will be used to characterize the integrated performance of major subsystem technologies, to evaluate hardware candidates and control strategies required for the CTF, and to further define the ability to meet CTF requirements within present Space Station constraints. This paper reviews the functional requirements for the EDU, and focuses on the performance evaluation and test results of the various subsystems. Preliminary integrated performance results and control system operation are addressed, and plans for future science and technology testing are discussed.

  16. A new feller-buncher for harvesting energy wood: Results from a European test programme

    Energy Technology Data Exchange (ETDEWEB)

    Spinelli, Raffaele [CNR-Ivalsa, Timber and Tree Institute, Sesto Fiorentino (Italy); Cuchet, Emmanuel [Afocel, Charrey sur Saone (France); Roux, Philippe [Cemagref, TEMO, Montpellier (France)

    2007-04-15

    In recent years, some manufacturers have developed new downsized feller-bunchers that are particularly suited to small-tree harvesting. One of these machines was tested in some of the most promising small tree resources of Europe, namely: Finnish young conifer forests, French hornbeam coppice and Italian sycamore plantations. The tests were conducted within the scope of a 3-year long European project, whose goal was to assess the suitability of this new technology to the production of wood biomass from silvicultural operations. Depending on site characteristics, the machine reached an average productivity between 4 and 8 green tonnes per net working hour, comparing favourably with other European shear-type felling heads and qualifying for deployment on a European scale. (author)

  17. Triaxial and Torsional Shear Test Results for Sand

    Science.gov (United States)

    1994-06-01

    densest and loosest packing of particles without crushing the grains. The standard test methods ASTM D4253-83 and D4254-83 were used to determine the...desired value of J (J = = I( j.2/+ 2 was reached. The sample was then sheared with a constant value of J. The mean norma stress p was held constant while oz...Triaxial Testing System", Advanced Triaxial Testing of Soil and Rock, ASTM , STP77, 1988, PP95-106. Miura, K, Miura, S. and Told, S., "Deformation Behavior

  18. THE LT-CFB GASIFIER – FIRST TEST RESULTS FROM THE 500 KW TEST PLANT

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Glar; Stoholm, Peder; Nielsen, Mads Brix

    2005-01-01

    The Low Temperature Circulating Fluidised Bed (LT-CFB) gasification process is briefly described together with the first test results from the new 500 kW test plant. The process aims primarily at co-firing low grade biomass and waste products at power plants and offer several advantages to direct...... in solid state, and can be separated from the gas using only a simple hot cyclone. Mass- and energy balances show that the conversion efficiency from fuel heating value to energy content in the product gas is more than 90% and even higher efficiencies are anticipated in upscaled plants....

  19. Results of thermal test of metallic molybdenum disk target and fast-acting valve testing

    Energy Technology Data Exchange (ETDEWEB)

    Virgo, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Gromov, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Jonah, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, G. F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    This report describes the irradiation conditions for thermal testing of helium-cooled metallic disk targets that was conducted on March 9, 2016, at the Argonne National Laboratory electron linac. The four disks in this irradiation were pressed and sintered by Oak Ridge National Laboratory from molybdenum metal powder. Two of those disks were instrumented with thermocouples. Also reported are results of testing a fast-acting-valve system, which was designed to protect the accelerator in case of a target-window failure.

  20. Clinical patterns and results of radioallergosorbent test (RAST) and skin tests in penicillin allergy.

    Science.gov (United States)

    Kraft, D; Wide, L

    1976-06-01

    Seventy-nine patients with acute or former reactions to penicillin were investigated by a benzylpenicilloyl (BPO)-specific RAST and/or by skin tests with penicilloyl-polylysine (PPL), benzylpenicillin and penicilloic acid and the results were correlated with the different clinical pictures. Positive RAST and skin test results could be found in patients with anaphylactic shock, urticaria and serum sickness-like reaction and sometimes in a special group of exanthems, which are characterized by the existence of many different lesions at the same time, therefore called 'polymorphic exanthems', and often observed after high-dosage penicillin therapy. In cases of scarlatiniform or morbilliform exanthems no positive results were found. The BPO-specific RAST showed an overall correlation of 95-I% with skin tests using PPL. However, some patients with positive skin tests to benzylpenicillin and penicilloic acid did no have detectable circulating IgE antibodies to BPO. This emphasizes the need for including these antigens in in vitro methods. The RAST was informative even at the allergic reaction or in the first 15 days afterwards and seems to be very valuable for early diagnosis of penicillin allergy especially in cases when many drugs have been given.

  1. Learning, Social Intelligence and the Turing Test - why an "out-of-the-box" Turing Machine will not pass the Turing Test

    CERN Document Server

    Edmonds, Bruce

    2012-01-01

    The Turing Test (TT) checks for human intelligence, rather than any putative general intelligence. It involves repeated interaction requiring learning in the form of adaption to the human conversation partner. It is a macro-level post-hoc test in contrast to the definition of a Turing Machine (TM), which is a prior micro-level definition. This raises the question of whether learning is just another computational process, i.e. can be implemented as a TM. Here we argue that learning or adaption is fundamentally different from computation, though it does involve processes that can be seen as computations. To illustrate this difference we compare (a) designing a TM and (b) learning a TM, defining them for the purpose of the argument. We show that there is a well-defined sequence of problems which are not effectively designable but are learnable, in the form of the bounded halting problem. Some characteristics of human intelligence are reviewed including it's: interactive nature, learning abilities, imitative tend...

  2. Speed test results and hardware/software study of computational speed problem, appendix D

    Science.gov (United States)

    1984-01-01

    The HP9845C is a desktop computer which is tested and evaluated for processing speed. A study was made to determine the availability and approximate cost of computers and/or hardware accessories necessary to meet the 20 ms sample period speed requirements. Additional requirements were that the control algorithm could be programmed in a high language and that the machine have sufficient storage to store the data from a complete experiment.

  3. Machine Learning in Parliament Elections

    Directory of Open Access Journals (Sweden)

    Ahmad Esfandiari

    2012-09-01

    Full Text Available Parliament is considered as one of the most important pillars of the country governance. The parliamentary elections and prediction it, had been considered by scholars of from various field like political science long ago. Some important features are used to model the results of consultative parliament elections. These features are as follows: reputation and popularity, political orientation, tradesmen's support, clergymen's support, support from political wings and the type of supportive wing. Two parameters of reputation and popularity and the support of clergymen and religious scholars that have more impact in reducing of prediction error in election results, have been used as input parameters in implementation. In this study, the Iranian parliamentary elections, modeled and predicted using learnable machines of neural network and neuro-fuzzy. Neuro-fuzzy machine combines the ability of knowledge representation of fuzzy sets and the learning power of neural networks simultaneously. In predicting the social and political behavior, the neural network is first trained by two learning algorithms using the training data set and then this machine predict the result on test data. Next, the learning of neuro-fuzzy inference machine is performed. Then, be compared the results of two machines.

  4. Study of surface integrity AISI 4140 as result of hard, dry and high speed machining using CBN

    Science.gov (United States)

    Ginting, B.; Sembiring, R. W.; Manurung, N.

    2017-09-01

    The concept of hard, dry and high speed machining can be combined, to produce high productivity, with lower production costs in manufacturing industry. Hard lathe process can be a solution to reduce production time. In lathe hard alloy steels reported problems relating to the integrity of such surface roughness, residual stress, the white layer and the surface integrity. AISI 4140 material is used for high reliable hydraulic system components. This material includes in cold work tool steel. Consideration election is because this material is able to be hardened up to 55 HRC. In this research, the experimental design using CCD model fit with three factors, each factor is composed of two levels, and six central point, experiments were conducted with 1 replications. The experimental design research using CCD model fit.

  5. Factors Resulting in Micron Indentation Hardness Descending in Indentation Tests

    Institute of Scientific and Technical Information of China (English)

    Li Min; Chen Weimin

    2009-01-01

    hardness decrease can be bated if the continuous stiffness measurement technique is not adopted; this indicates that the test method itself may also be one of the factors causing the hardness being descended.

  6. Results from a pilot cell test of cermet anodes

    Energy Technology Data Exchange (ETDEWEB)

    Windisch, Jr, C F; Strachan, D M; Henager, Jr, C H; Greenwell, E N [Pacific Northwest Lab., Richland, WA (United States); Alcorn, T R [Reynolds Metals Co., Muscle Shoals, AL (United States). Mfg. Technology Lab.

    1992-08-01

    Goal was to develop long-lasting, energy-efficient anodes for Hall-Heroult cells used to produce Al metal. The anodes were made from a ceramic/metal composite consisting of NiO and NiFe{sub 2}O{sub 4} and a Cu/Ni metal phase. Thirteen cermet anodes were tested at Reynolds Metals Co., Muscle Shoals, AL. All anodes corroded severely during the pilot test. Electrolyte components were found deep within the anodes. However, there were many deficiencies in the pilot cell test, mainly the failure to maintain optimal operating conditions. It is concluded that there is a variety of fabrication and operational considerations that need to be addressed carefully in any future testing. 118 figs, 16 tabs, 17 refs.(DLC)

  7. Miniature Sensor Technology Integration (MSTI) Flight Test Results

    OpenAIRE

    Erickson, David; Feig, Jason; Grigsby, Ed; Carlson, Alan

    1994-01-01

    The MSTI-2 satellite mission is the second in a series established to test, in realistic scenarios, miniature spacecraft and sensor technologies for missile detection and tracking on low cost, low-earth orbit technology demonstration satellites. Cooperative demonstrations are planned to combine MSTI-provided target track file information, with interceptor technology tests, to fully demonstrate technologies associated with theater missile defense (TMO) targeting. The program is sponsored by th...

  8. U.S. field testing programs and results

    Energy Technology Data Exchange (ETDEWEB)

    Wicks, G.G.

    2000-06-09

    The United States has been active in four major international in-situ or field testing programs over the past two decades, involving the burial of simulated high-level waste forms and package components. These programs are designed to supplement laboratory testing studies in order to obtain the most complete and realistic picture possible of waste glass behavior under realistic repository-relevant conditions.

  9. CHALLENGE TESTS WITH LISTERIA MONOCYTOGENES IN SALAMI: PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    R. Mioni

    2013-02-01

    Full Text Available Challenge tests are the preferable methodology to study the behaviour of Listeria monocytogenes on ready to eat foods, according to Regulation (EC 2073/2005. Challenge testing using L. monocytogenes in seasoned salami from different food business operators showed, after seasoning of the product, a count reduction of the inoculated organisms without any further growth of the pathogen; however differences of L. monocytogenes behaviour could be observed according to different production protocols.

  10. Tests of the 'Convergence Hypothesis': Some Further Results

    OpenAIRE

    Cohen, Daniel

    1995-01-01

    This paper offers new tests of the `convergence hypothesis'. It first analyses the pattern of growth of measured inputs (human and physical capital conventionally measured by an inventory method) and shows that these tests sustain the hypothesis. On the other hand, when the pattern of growth of revealed inputs (physical capital and Solow residual) is analysed, one is led to reject the convergence theory. In order to understand what lies at the heart of this discrepancy, the paper shows that t...

  11. Coordinate measuring machines

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    This document is used in connection with three exercises of 2 hours duration as a part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The exercises concern three aspects of coordinate measuring: 1) Measuring and verification of tolerances on coordinate measuring machines, 2) Traceability...

  12. Learning Machine Learning: A Case Study

    Science.gov (United States)

    Lavesson, N.

    2010-01-01

    This correspondence reports on a case study conducted in the Master's-level Machine Learning (ML) course at Blekinge Institute of Technology, Sweden. The students participated in a self-assessment test and a diagnostic test of prerequisite subjects, and their results on these tests are correlated with their achievement of the course's learning…

  13. Learning Machine Learning: A Case Study

    Science.gov (United States)

    Lavesson, N.

    2010-01-01

    This correspondence reports on a case study conducted in the Master's-level Machine Learning (ML) course at Blekinge Institute of Technology, Sweden. The students participated in a self-assessment test and a diagnostic test of prerequisite subjects, and their results on these tests are correlated with their achievement of the course's learning…

  14. HESTIA Phase I Test Results: The Air Revitalization System

    Science.gov (United States)

    Wright, Sarah E.; Hansen, Scott W.

    2016-01-01

    In any human spaceflight mission, a number of Environmental Control & Life Support System (ECLSS) technologies work together to provide the conditions astronauts need to live healthily, productively, and comfortably in space. In a long-duration mission, many of these ECLSS technologies may use materials supplied by In-Situ Resource Utilization (ISRU), introducing more interactions between systems. The Human Exploration Spacecraft Test-bed for Integration & Advancement (HESTIA) Project aims to create a test-bed to evaluate ECLSS and ISRU technologies and how they interact in a high-fidelity, closed-loop, human-rated analog habitat. Air purity and conditioning are essential components within any ECLSS and for HESTIA's first test they were achieved with the Air Revitalization System (ARS) described below. The ARS provided four essential functions to the test-bed chamber: cooling the air, removing humidity from the air, removing trace contaminants, and scrubbing carbon dioxide (CO2) from the air. In this case, the oxygen supply function was provided by ISRU. In the current configuration, the ARS is a collection of different subsystems. A fan circulates the air, while a condensing heat exchanger (CHX) pulls humidity out of the air. A Trace Contaminant Removal System (TCRS) filters the air of potentially harmful contaminants. Lastly, a Reactive Plastic Lithium Hydroxide (RP-LiOH) unit removes CO2 from the breathing air. During the HESTIA Phase I test in September 2015, the ARS and its individual components each functioned as expected, although further analysis is underway. During the Phase I testing and in prior bench-top tests, the energy balance of heat removed by the CHX was not equal to the cooling it received. This indicated possible instrument error and therefore recalibration of the instruments and follow-up testing is planned in 2016 to address the issue. The ARS was tested in conjunction with two other systems: the Human Metabolic Simulator (HMS) and the

  15. Data on test results of vessel cooling system of high temperature engineering test reactor

    Energy Technology Data Exchange (ETDEWEB)

    Saikusa, Akio [Secretariat of Nuclear Safety Commission, Tokyo (Japan); Nakagawa, Shigeaki; Fujimoto, Nozomu; Tachibana, Yukio; Iyoku, Tatsuo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2003-02-01

    High Temperature Engineering Test Reactor (HTTR) is the first graphite-moderated helium gas cooled reactor in Japan. The rise-to-power test of the HTTR started on September 28, 1999 and thermal power of the HTTR reached its full power of 30 MW on December 7, 2001. Vessel Cooling System (VCS) of the HTTR is the first Reactor Cavity Cooling System (RCCS) applied for High Temperature Gas Cooled Reactors. The VCS cools the core indirectly through the reactor pressure vessel to keep core integrity during the loss of core flow accidents such as depressurization accident. Minimum heat removal of the VCS to satisfy its safety requirement is 0.3MW at 30 MW power operation. Through the performance test of the VCS in the rise-to-power test of the HTTR, it was confirmed that the VCS heat removal at 30 MW power operation was higher than 0.3 MW. This paper shows outline of the VCS and test results on the VCS performance. (author)

  16. Aluminum Stabilized NbTi Conductor Test Coil Design, Fabrication, and Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, N.; Chlachidze, G.; Evbota, D.; Kashikhin, V.S.; Lamm, M.; Makarov, A.; Tartaglia, M.; /Fermilab; Nakamoto, T.; Ogitsu, T.; Tanaka, K.; Yamamoto, A.; /KEK, Tsukuba

    2011-09-01

    A new generation of precision muon conversion experiments is planned at both Fermilab and KEK. These experiments will depend upon a complex set of solenoid magnets for the production, momentum selection and transport of a muon beam to a stopping target, and for tracking detector momentum analysis of candidate conversion electrons from the target. Baseline designs for the production and detector solenoids use NbTi cable that is heavily stabilized by an extruded high RRR aluminum jacket. A U.S.-Japan research collaboration has begun whose goal is to advance the development of optimized Al-NbTi conductors, gain experience with the technology of winding coils from this material, and test the conductor performance as modest length samples become available. For this purpose, a 'conductor test' solenoid with three coils was designed and built at Fermilab. A sample of the RIKEN Al-NbTi conductor from KEK was wound into a 'test' coil; this was sandwiched between two 'field' coils wound from doubled SSC cable, to increase the peak field on the RIKEN test coil. All three solenoid coils were epoxy impregnated, and utilized aluminum outer bandage rings to apply preload to the coils when cold. The design and fabrication details, and results of the magnet quench performance tests are presented and discussed.

  17. ESO adaptive optics facility progress and first laboratory test results

    Science.gov (United States)

    Arsenault, Robin; Madec, Pierre-Yves; Paufique, Jérome; La Penna, Paolo; Stroebele, Stefan; Vernet, Elise; Pirard, Jean-Francois; Hackenberg, Wolfgang; Kuntschner, Harald; Kolb, Johann; Muller, Nicolas; Garcia-Rissmann, Aurea; Le Louarn, Miska; Amico, Paola; Hubin, Norbert; Lizon, Jean-Louis; Ridings, Rob; Haguenauer, Pierre; Abad, Jose A.; Fischer, Gerhard; Heinz, Volker; Kiekebusch, Mario; Argomedo, Javier; Conzelmann, Ralf; Tordo, Sebastien; Donaldson, Rob; Soenke, Christian; Duhoux, Philippe; Fedrigo, Enrico; Delabre, Bernard; Jost, Andrea; Duchateau, Michel; Downing, Mark; Reyes Moreno, Javier; Manescau, Antonio; Bonaccini Calia, Domenico; Quattri, Marco; Dupuy, Christophe; Guidolin, Ivan M.; Comin, Mauro; Guzman, Ronald; Buzzoni, Bernard; Quentin, Jutta; Lewis, Steffan; Jolley, Paul; Kraus, Max; Pfrommer, Thomas; Biasi, Roberto; Gallieni, Daniele; Stuik, Remko; Kaenders, Wilhelm; Ernstberger, Bernhard; Friedenauer, Axel

    2014-07-01

    The Adaptive Optics Facility project is completing the integration of its systems at ESO Headquarters in Garching. The main test bench ASSIST and the 2nd Generation M2-Unit (hosting the Deformable Secondary Mirror) have been granted acceptance late 2012. The DSM has undergone a series of tests on ASSIST in 2013 which have validated its optical performance and launched the System Test Phase of the AOF. This has been followed by the performance evaluation of the GRAAL natural guide star mode on-axis and will continue in 2014 with its Ground Layer AO mode. The GALACSI module (for MUSE) Wide-Field-Mode (GLAO) and the more challenging Narrow-Field-Mode (LTAO) will then be tested. The AOF has also taken delivery of the second scientific thin shell mirror and the first 22 Watt Sodium laser Unit. We will report on the system tests status, the performances evaluated on the ASSIST bench and advancement of the 4Laser Guide Star Facility. We will also present the near future plans for commissioning on the telescope and some considerations on tools to ensure an efficient operation of the Facility in Paranal.

  18. Hypervelocity Impact Test Results for a Metallic Thermal Protection System

    Science.gov (United States)

    Karr, Katherine L.; Poteet, Carl C.; Blosser, Max L.

    2003-01-01

    Hypervelocity impact tests have been performed on specimens representing metallic thermal protection systems (TPS) developed at NASA Langley Research Center for use on next-generation reusable launch vehicles (RLV). The majority of the specimens tested consists of a foil gauge exterior honeycomb panel, composed of either Inconel 617 or Ti-6Al-4V, backed with 2.0 in. of fibrous insulation and a final Ti-6Al-4V foil layer. Other tested specimens include titanium multi-wall sandwich coupons as well as TPS using a second honeycomb sandwich in place of the foil backing. Hypervelocity impact tests were performed at the NASA Marshall Space Flight Center Orbital Debris Simulation Facility. An improved test fixture was designed and fabricated to hold specimens firmly in place during impact. Projectile diameter, honeycomb sandwich material, honeycomb sandwich facesheet thickness, and honeycomb core cell size were examined to determine the influence of TPS configuration on the level of protection provided to the substructure (crew, cabin, fuel tank, etc.) against micrometeoroid or orbit debris impacts. Pictures and descriptions of the damage to each specimen are included.

  19. Hunter standoff killer team (HSKT) ground and flight test results

    Science.gov (United States)

    Moreland, Balinda; Ennis, Mark; Yeates, Robert; Condon, Timothy

    2007-04-01

    Warfighter's Associate (WA) which was integrated onto the Apache Longbow, and the Mobile Commanders Associate (MCA) which was integrated onto the Army Airborne Command and Control System (A2C2S) UH-60 Blackhawk. In this paper we will discuss what WA and MCA provided to the warfighter, and the results of the HSKT ground and flight testing.

  20. CSI Flight Computer System and experimental test results

    Science.gov (United States)

    Sparks, Dean W., Jr.; Peri, F., Jr.; Schuler, P.

    1993-01-01

    This paper describes the CSI Computer System (CCS) and the experimental tests performed to validate its functionality. This system is comprised of two major components: the space flight qualified Excitation and Damping Subsystem (EDS) which performs controls calculations; and the Remote Interface Unit (RIU) which is used for data acquisition, transmission, and filtering. The flight-like RIU is the interface between the EDS and the sensors and actuators positioned on the particular structure under control. The EDS and RIU communicate over the MIL-STD-1553B, a space flight qualified bus. To test the CCS under realistic conditions, it was connected to the Phase-0 CSI Evolutionary Model (CEM) at NASA Langley Research Center. The following schematic shows how the CCS is connected to the CEM. Various tests were performed which validated the ability of the system to perform control/structures experiments.

  1. Laser Machining of Melt Infiltrated Ceramic Matrix Composite

    Science.gov (United States)

    Jarmon, D. C.; Ojard, G.; Brewer, D.

    2012-01-01

    As interest grows in considering the use of ceramic matrix composites for critical components, the effects of different machining techniques, and the resulting machined surfaces, on strength need to be understood. This work presents the characterization of a Melt Infiltrated SiC/SiC composite material system machined by different methods. While a range of machining approaches were initially considered, only diamond grinding and laser machining were investigated on a series of tensile coupons. The coupons were tested for residual tensile strength, after a stressed steam exposure cycle. The data clearly differentiated the laser machined coupons as having better capability for the samples tested. These results, along with micro-structural characterization, will be presented.

  2. Mechanical test results from the EU testing program for potential ITER insulation material

    Energy Technology Data Exchange (ETDEWEB)

    Broadbent, A.J.; Butt, S.; Smith, K.D. [Oxford Instruments, Witney (United Kingdom)] [and others

    1997-06-01

    Insulation systems will be a key element in the future construction and impregnation of the coils for the ITER device. Candidate materials must survive prolonged irradiation (2.5 x 10{sup 21} - 2.5 x 10{sup 22} neutrons/m{sup 2} - September 1994) simultaneous high compressive and shear stresses (up to 300 MPa and 50 MPa respectively), and have high electrical reliability (30 year service life). The materials chosen are intended to meet the demands of full scale coil manufacture. Mechanical properties, including shear / compression and compression at cryogenic temperatures of several different insulation systems are reported. The mechanically acceptable systems will be irradiation tested at a future date, although only materials believed to withstand high irradiation doses have been selected. The final results of this program are presented and compared with a pass / fail criterion based on results from a benchmark testing program (insulation system based on anhydride cured DGEBA resin and S2 glass).

  3. Performance of CREAM Calorimeter Results of Beam Tests

    CERN Document Server

    Ahn, H S; Beatty, J J; Bigongiari, G; Castellina, A; Childers, J T; Conklin, N B; Coutu, S; Duvernois, M A; Ganel, O; Han, J H; Hyun, H J; Kang, T G; Kim, H J; Kim, K C; Kim, M Y; Kim, T; Kim, Y J; Lee, J K; Lee, M H; Lutz, L; Maestro, P; Malinine, A; Marrocchesi, P S; Mognet, S I; Nam, S W; Nutter, S; Park, N H; Park, H; Seo, E S; Sina, R; Syed, S; Song, C; Swordy, S; Wu, J; Yang, J; Zhang, H Q; Zei, R; Zinn, S Y

    2005-01-01

    The Cosmic Ray Energetics And Mass (CREAM), a balloon-borne experiment, is under preparation for a flight in Antarctica at the end of 2004. CREAM is planned to measure the energy spectrum and composition of cosmic rays directly at energies between 1 TeV and 1000 TeV. Incident particle energies will be measured by a transition radiation detector and a sampling calorimeter. The calorimeter was constructed at the University of Maryland and tested at CERN in 2003. Performance of the calorimeter during the beam tests is reported.

  4. Analysis of behaviour of transonic profiles with strong curvature: Test facilities, instrumentation, test results, theoretical interpretations

    Energy Technology Data Exchange (ETDEWEB)

    Pittaluga, G.; Benvenuto, G. (Udine Univ. (Italy); L' Aquila Univ. (Italy))

    1988-06-01

    Relevant to experimental investigations on the performance of a transonic turbine blade cascade, this paper discusses recent developments regarding the following topics: the experimental equipment and relative instrumentation; the results of tests on turbine blade cascades; the conceptual methods specifically developed and aimed at the optimized design of steam turbines systems and turbine blades; the theoretical-numerical procedures developed and applied as supports for theoretical-experimental analyses and the redesign of blade profiles to increase efficiency.

  5. Results from Carbon Dioxide Washout Testing Using a Suited Manikin Test Apparatus with a Space Suit Ventilation Test Loop

    Science.gov (United States)

    Chullen, Cinda; Conger, Bruce; McMillin, Summer; Vonau, Walt; Kanne, Bryan; Korona, Adam; Swickrath, Mike

    2016-01-01

    NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS is one of the most critical aspects of the space suit providing the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The ventilation subsystem in the PLSS must provide sufficient carbon dioxide (CO2) removal and ensure that the CO2 is washed away from the oronasal region of the astronaut. CO2 washout is a term used to describe the mechanism by which CO2 levels are controlled within the helmet to limit the concentration of CO2 inhaled by the astronaut. Accumulation of CO2 in the helmet or throughout the ventilation loop could cause the suited astronaut to experience hypercapnia (excessive carbon dioxide in the blood). A suited manikin test apparatus (SMTA) integrated with a space suit ventilation test loop was designed, developed, and assembled at NASA in order to experimentally validate adequate CO2 removal throughout the PLSS ventilation subsystem and to quantify CO2 washout performance under various conditions. The test results from this integrated system will be used to validate analytical models and augment human testing. This paper presents the system integration of the PLSS ventilation test loop with the SMTA including the newly developed regenerative Rapid Cycle Amine component used for CO2 removal and tidal breathing capability to emulate the human. The testing and analytical results of the integrated system are presented along with future work.

  6. Architectural design and first results evaluation of the PowerMatching City field test

    Energy Technology Data Exchange (ETDEWEB)

    Kamphuis, I.G.; Roossien, B. [Unit Efficiency and Infrastructure, Energy research Centre of the Netherlands, Westerduinweg 3, P.O. Box 1, 1755 ZG Petten (Netherlands); Bliek, F.W.; Van den Noort, A. [KEMA/Gas Consultancy Services, Groningen (Netherlands); Van de Velde, J.; De Wit, J. [HUMIQ, Groningen (Netherlands)

    2011-01-15

    Starting from the beginning of 2010, in the EU FP6 Integral4 project, a large-scale SmartGrid field test with active participation of end-user installation nodes in the electricity network is running. A high-bandwidth dedicated ICTnetwork has been rolled-out to connect electricity supply and demand nodes and to collect data. In the test, the software agent based PowerMatcher technology is applied in a Virtual Power Plant (VPP) setting to satisfy a number of commercial and grid related optimization objectives. The VPP in the test consists of 25 heating devices in homes in Hoogkerk, nodes with PV and wind generated electricity, residential and mobile (full EV's) electricity storage nodes and intelligent home appliances. Primary process flexibility for the heating system's hybrid heat pumps and micro-CHP is enlarged by using hot water filled heat buffers. Additional gas burning heating capacity to be used in peak periods was added to the system configuration. Additional demand response flexibility is achieved by optimizing the charging strategy of the nodes with electricity storage and the operation of devices connected to demands like refrigerators and washing machines. In this way, on a real-time basis, the VPP has been shown to be usable for optimization to satisfy objectives for compensation of the variable output of renewables, for improving grid operation and functions for commercial operation. In this paper the architectural design and the application of the PowerMatcher approach is evaluated. The first results of operating the use cases are also presented.

  7. Still just 1 g: Consistent results from five test batteries

    NARCIS (Netherlands)

    Johnson, W.; te Nijenhuis, J.; Bouchard, T.J.Jr.

    2008-01-01

    In a recent paper, Johnson, Bouchard, Krueger,McGue, and Gottesman (2004) addressed a long-standing debate in psychology by demonstrating that the g factors derived from three test batteries administered to a single group of individuals were completely correlated. This finding provided evidence for

  8. Results of Caisson Breakwater Tests in Multidirectional Breaking Seas

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    In extension of the work done at the Hydraulics and Coastal Engineering Laboratory, Dept. of Civil Engineering, Aalborg University, Denmark, described in Grønbech et al., 1997, laboratory tests has been performed investigating wave loading and overtopping on caisson breakwaters in multidirectional...

  9. TEST RESULTS FOR FUEL CELL OPERATION ON ANAEROBIC DIGESTER GAS

    Science.gov (United States)

    EPA, in conjunction with ONSI Corp., embarked on a project to define, design, test, and assess a fuel cell energy recovery system for application at anaerobic digester waste water (sewage) treatment plants. Anaerobic digester gas (ADG) is produced at these plants during the proce...

  10. Results of the quality assurance testing program for radiopharmaceuticals, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Baldas, J.; Bonnyman, J.; Ivanov, Z.; Lauder, R

    1995-08-01

    The Australian Radiation Laboratory conducts a Radiopharmaceutical Quality Assurance Test Program in which radiopharmaceuticals used in nuclear medicine in Australia are tested for compliance with specifications. Where the radiopharmaceutical is the subject of a monograph in the British Pharmacopoeia or the European Pharmacopoeia, then the specifications given in the Pharmacopoeia are adopted. In other cases the specifications quoted have been adopted by this Laboratory and have no legal status. It should be noted that unless stated otherwise, the specifications listed apply at all times up to product expiry. Radionuclidic purity has been determined at the calibration time, except for Thallous [{sup 201}Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Samples for testing were obtained through commercial channels. All technetium-99m cold kits were reconstituted according to the directions in the package insert using Sodium Pertechnetate[{sup 99m}Tc] Injection. Methods used for testing are described in the report ARL/TR093 24 tabs.

  11. Results of Laboratory Testing of Advanced Power Strips

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-08-01

    Presented at the ACEEE Summer Study on Energy Efficiency in Buildings on August 12-17, 2012, this presentation reports on laboratory tests of 20 currently available advanced power strip products, which reduce wasteful electricity use of miscellaneous electric loads in buildings.

  12. Results of Statewide TerraNova Testing, Fall 1998.

    Science.gov (United States)

    La Marca, Paul M.

    This summary provides key findings about state, district, and school level performance on the TerraNova examinations (CTB/McGraw Hill) in Nevada in 1998-1999. The TerraNova tests are used to assess students in grades 4, 8, and 10 as stipulated by Nevada law. Within this summary, a description of performance as measured by national percentile…

  13. Laser Welding Test Results with Gas Atmospheres in Welding Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Hong, Jin-Tae; Ahn, Sung-Ho; Heo, Sung-Ho; Jang, Seo-Yun; Yang, Tae-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The weld beads of specimens welded under identical conditions in the helium and argon gas were cleaner, more regular, and steadier than those in a vacuum. The penetration depth of the FZ in the vacuum was much deeper than those in the helium and argon gas. To measure the irradiation properties of nuclear fuel in a test reactor, a nuclear fuel test rod instrumented with various sensors must be fabricated with assembly processes. A laser welding system to assemble the nuclear fuel test rod was designed and fabricated to develop various welding technologies of the fuel test rods to joint between a cladding tube and end-caps. It is an air-cooling optical fiber type and its emission modes are a continuous (CW) mode of which the laser generates continuous emission, and pulse (QCW) mode in which the laser internally generates sequences of pulses. We considered the system welding a sample in a chamber that can weld a specimen in a vacuum and inert gas atmosphere, and the chamber was installed on the working plate of the laser welding system. In the chamber, the laser welding process should be conducted to have no defects on the sealing area between a cladding tube and an end-cap.

  14. Preliminary Results of Breakwater Round-Head Tests

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    1995-01-01

    The rational design diagram for Dolos armour should incorporate both the hydraulic stability and the structural integrity. The previous tests performed by Aalborg University (AU) made available such design diagram for the trunk of Dolos breakwater without superstructures (Burcharth et al. 1992...

  15. Discussion on Methodologies for QC Testing of Hemodialysis Machines and Relevant Problems%血液透析机质控检测方法及问题探讨

    Institute of Scientific and Technical Information of China (English)

    武振虎

    2015-01-01

    With deployment of the testing instrument for QC (Quality Control) of hemodialysis machines, 42 hemodialysis machines in the hospital were tested from 7 aspects including the temperature, conductivity and flow volume of dialyzate as well as the flow rate of the heparin pump. This paper expounded the signiifcance, methodology and results of QC testing of hemodialysis machines and put forward the existing problems and relevant solutions.%使用血液透析机质控检测仪,对我院42台血液透析机的透析液温度及电导率、透析液流量及肝素泵流速等7个项目进行了检测,本文对质控检测的意义、方法、检测结果,以及对发现的问题和解决办法进行了阐述。

  16. THE LT-CFB GASIFIER – FIRST TEST RESULTS FROM THE 500 KW TEST PLANT

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Glar; Stoholm, Peder; Nielsen, Mads Brix

    2005-01-01

    The Low Temperature Circulating Fluidised Bed (LT-CFB) gasification process is briefly described together with the first test results from the new 500 kW test plant. The process aims primarily at co-firing low grade biomass and waste products at power plants and offer several advantages to directly...... co-firing: E.g. the ashes of different fuels can be kept separate, and corrosion and fouling of the furnace can be drastically reduced. Three fuels have been tested so far on this plant: High ash straw (12% ash, dry), dry matter from pig manure (28% ash, dry) and dry matter from biogas residue based...... on pig manure (44% ash, dry). All the tests have been very stable and a steady state content of ash components, e.g. potassium, in the ash and bed material was reached. The low temperature (max. 750°C) ensures that there are no agglomeration problems, and that almost 100% of K, Si, Ca and P is kept...

  17. Machine Translation

    Institute of Scientific and Technical Information of China (English)

    张严心

    2015-01-01

    As a kind of ancillary translation tool, Machine Translation has been paid increasing attention to and received different kinds of study by a great deal of researchers and scholars for a long time. To know the definition of Machine Translation and to analyse its benefits and problems are significant for translators in order to make good use of Machine Translation, and helpful to develop and consummate Machine Translation Systems in the future.

  18. 3D silicon pixel sensors: Recent test beam results

    CERN Document Server

    Hansson, P; Sandaker, H; Korolkov, I; Barrera, C; Wermes, N; Borri, M; Grinstein, S; Troyano, I; Grenier, P; Devetak, E; Fleta, C; Kenney, C; Tsybychev, D; Nellist, C; Chmeissan, M; Su, D; DeWilde, B; Silverstein, D; Dorholt, O; Tsung, J; Sjoebaek, K; Stupak, J; Slaviec, T; Micelli, A; Helle, K; Bolle, E; Huegging, F; Kocian, M; Fazio, S; Balbuena, J; Dalla Betta, G F; La Rosa, A; Rivero, F; Mastroberardino, A; Hasi, J; Darbo, G; Boscardin, M; Da Via, C; Nordahl, P; Giordani, M; Jackson, P; Rohne, O; Gemme, C; Young, C

    2011-01-01

    The 3D silicon sensors aimed for the ATLAS pixel detector upgrade have been tested with a high energy pion beam at the CERN SPS in 2009. Two types of sensor layouts were tested: full-3D assemblies fabricated in Stanford, where the electrodes penetrate the entire silicon wafer thickness, and modified-3D assemblies fabricated at FBK-irst with partially overlapping electrodes. In both cases three read-out electrodes are ganged together to form pixels of dimension 50 x 400 mu m(2). Data on the pulse height distribution, tracking efficiency and resolution were collected for various particle incident angles, with and without a 1.6 T magnetic field. Data from a planar sensor of the type presently used in the ATLAS detector were used at the same time to give comparison. Published by Elsevier B.V.

  19. 3D silicon pixel sensors: Recent test beam results

    Energy Technology Data Exchange (ETDEWEB)

    Hansson, P., E-mail: phansson@cern.c [University of Oslo (Norway); Balbuena, J.; Barrera, C. [CNM Barcelona (Spain); Bolle, E. [University of Oslo (Norway); Borri, M. [Torino University (Italy); Boscardin, M. [FBK Trento (Italy); Chmeissan, M. [IFAE Barcelona (Spain); Dalla Betta, G.-F. [Universita di Trento and INFN Trento (Italy); Darbo, G. [INFN Genova (Italy); Da Via, C. [University of Manchester (United Kingdom); Devetak, E.; DeWilde, B. [Stony Brook University (United States); Su, D. [SLAC (United States); Dorholt, O. [University of Oslo (Norway); Fazio, S. [Calabria University (Italy); Fleta, C. [CNM Barcelona (Spain); Gemme, C. [INFN Genova (Italy); Giordani, M. [University of Udine and INFN Udine (Italy); Gjersdal, H. [University of Oslo (Norway); Grenier, P. [SLAC (United States)

    2011-02-01

    The 3D silicon sensors aimed for the ATLAS pixel detector upgrade have been tested with a high energy pion beam at the CERN SPS in 2009. Two types of sensor layouts were tested: full-3D assemblies fabricated in Stanford, where the electrodes penetrate the entire silicon wafer thickness, and modified-3D assemblies fabricated at FBK-irst with partially overlapping electrodes. In both cases three read-out electrodes are ganged together to form pixels of dimension 50x400{mu}m{sup 2}. Data on the pulse height distribution, tracking efficiency and resolution were collected for various particle incident angles, with and without a 1.6 T magnetic field. Data from a planar sensor of the type presently used in the ATLAS detector were used at the same time to give comparison.

  20. Test beam results of LHCb scintillating fibre tracker prototypes

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, Sebastian; Comerma, Albert; Gerick, David; Hansmann-Menzemer, Stephanie; Kecke, Matthieu; Leverington, Blake; Mazorra de Cos, Jose; Mitzel, Dominik; Neuner, Max; Uwer, Ulrich; Han, Xiaoxue [Physikalisches Institut, Universitaet Heidelberg (Germany); Collaboration: LHCb-Collaboration

    2016-07-01

    During the Long Shutdown 2 of the LHC, the LHCb detector will undergo a major upgrade to meet the challenges of running at a higher luminosity. The current Inner and Outer Tracking system will not be sufficient to deal with the envisaged increased detector occupancy and higher radiation levels and will be replaced by a single tracking detector based on 0.250 mm diameter plastic scintillating fibres. The fibres are wound to multilayer ribbons 2.4 m long and read out by 128 channel silicon photomultiplier arrays. The Scintillating Fibre (SciFi) tracker will cover a total active area of 360 m{sup 2}, arranged in 12 layers. The performances of prototype modules having 6 and 8 layers of fibre have been tested at the SPS at CERN. This talk focuses on basic properties of the prototype modules such as spatial resolution, single hit efficiency and light yield measured during the test beam campaigns in 2015.

  1. Design and preliminary test results of Daya Bay RPC modules*

    Energy Technology Data Exchange (ETDEWEB)

    Hackenburg, R.

    2011-09-01

    Resistive Plate Chamber (RPC) modules will be used as one part of the cosmic muon veto system in the Daya Bay reactor neutrino experiment. A total of 189 RPC modules will cover the three water pools in the experiment. To achieve track reconstruction and high efficiency, each module consists of 4 layers, each of which contains two sizes of bare chambers. The placement of bare chambers is reversed in different layers to reduce the overlapping dead areas. The module efficiency and patch efficiency were studied both in simulation and test of the data analysis. 143 modules have been constructed and tested. The preliminary study shows that the module and patch 3 out of 4 layers efficiency reaches about 98%.

  2. Design and preliminary test results of Daya Bay RPC modules

    Institute of Scientific and Technical Information of China (English)

    XU Ji-Lei; Logan Lebanowski; Cullen Newsom; Lin Shih-Kai; Jonathan Link; MA Lie-Hua; Viktor Pě(c); Vit Vorobel; CHEN Jin; LIU Jin-Chang; ZHOU Yong-Zhao; GUAN Meng-Yun; LIANG Hao; YANG Chang-Gen; WANG Yi-Fang; ZHANG Jia-Wen; LU Chang-Guo; Kirk McDonald; Robert Hackenburg; Kwong Lau

    2011-01-01

    Resistive Plate Chamber(RPC)modules will be used as one part of the cosmic muon veto system in the Days Bay reactor neutrino experiment.A total of 189 RPC modules will cover the three water pools in the experiment.To achieve track reconstruction and high efficiency,each module consists of 4 layers,each of which contains two sizes of bare chambers.The placement of bare chambers is reversed in different layers to reduce the overlapping dead areas.The module efficiency and patch efficiency were studied both in simulation and test of the data analysis.143 modules have been constructed and tested.The preliminary study shows that the module and patch 3 out of 4 layers efficiency reaches about 98%.

  3. HVEPS Scramjet-Driven MHD Power Demonstration Test Results (Preprint)

    Science.gov (United States)

    2007-06-01

    seeding for the scramjet- driven MHD demonstration test was accomplished by the injection of liquid NaK into the backplate of the UTRC pre-heater... NaK is a eutectic consisting of approximately 80% potassium and 20% sodium. It exists in liquid form at room temperature and has flow properties...quite similar to water. However, there are materials handling safety issues with use of NaK since it is highly caustic alkali metal and burns on

  4. A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Mozzo, P. [Dept. of Medical Physics, University Hospital, Verona (Italy); Procacci, C.; Tacconi, A.; Tinazzi Martini, P.; Bergamo Andreis, I.A. [Dept. of Radiology, University Hospital, Verona (Italy)

    1998-12-01

    The objective of this paper is to present a new type of volumetric CT which uses the cone-beam technique instead of traditional fan-beam technique. The machine is dedicated to the dento-maxillo-facial imaging, particularly for planning in the field of implantology. The main characteristics of the unit are presented with reference to the technical parameters as well as the software performance. Images obtained are reported as various 2D sections of a volume reconstruction. Also, measurements of the geometric accuracy and the radiation dose absorbed by the patient are obtained using specific phantoms. Absorbed dose is compared with that given off by spiral CT. Geometric accuracy, evaluated with reference to various reconstruction modalities and different spatial orientations, is 0.8-1 % for width measurements and 2.2 % for height measurements. Radiation dose absorbed during the scan shows different profiles in central and peripheral axes. As regards the maximum value of the central profile, dose from the new unit is approximately one sixth that of traditional spiral CT. The new system appears to be very promising in dento-maxillo-facial imaging and, due to the good ratio between performance and low cost, together with low radiation dose, very interesting in view of large-scale use of the CT technique in such diagnostic applications. (orig.) With 10 figs., 3 tabs., 15 refs.

  5. Operating experiences and test results of six cold helium compressors

    Science.gov (United States)

    Brown, D. P.; Gibbs, R. J.; Schlafke, A. P.; Sondericker, J. H.; Wu, K. C.

    Three small and three large cold helium centrifugal compressors have been operated at Brookhaven National Laboratory between 1981 and 1986. The three small cold compressors have been installed on a 1000 W refrigerator for testing a string of superconducting magnets and for R and D purposes. The three large units are components of the BNL 24.8 KW refrigerator to be used to provide cooling for the RHIC project. These compressors are used either to circulate a large amount of supercritical helium through a group of magnets or to pump on the helium bath to reduce temperature in the system. One small circulating compressor tested employs tilting-pad gas bearings and is driven by a DC motor. The two small cold vacuum pumps tested use oil bearings and are driven by oil turbines. The three large oil-bearing cold compressors are driven by DC motors through a gear box. A unique feature of the large vacuum pump is the combination of two pumps with a total of four stages on the same shaft. The adiabatic efficiencies are found to be 57% for the large vacuum pumps and close to 50% for the large circulating compressor. Good overall reliability has been experienced.

  6. Pseudomonas pellicle in disinfectant testing: electron microscopy, pellicle removal, and effect on test results.

    Science.gov (United States)

    Cole, E C; Rutala, W A; Carson, J L; Alfano, E M

    1989-01-01

    Pseudomonas aeruginosa ATCC 15442 is a required organism in the Association of Official Analytical Chemists use-dilution method for disinfectant efficacy testing. When grown in a liquid medium, P. aeruginosa produces a dense mat or pellicle at the broth/air interface. The purpose of this investigation was to examine the pellicle by scanning electron microscopy, to evaluate three pellicle removal methods, and to determine the effect of pellicle fragments on disinfectant efficacy test results. The efficacies of three methods of pellicle removal (decanting, vacuum suction, and filtration) were assessed by quantifying cell numbers on penicylinders. The Association of Official Analytical Chemists use-dilution method was used to determine whether pellicle fragments in the tubes used to inoculate penicylinders affected test results. Scanning electron micrographs showed the pellicle to be a dense mass of intact, interlacing cells at least 10 microns thick. No significant differences in pellicle removal methods were observed, and the presence of pellicle fragments usually increased the number of positive tubes in the use-dilution method significantly. Images PMID:2497711

  7. Sustainable machining

    CERN Document Server

    2017-01-01

    This book provides an overview on current sustainable machining. Its chapters cover the concept in economic, social and environmental dimensions. It provides the reader with proper ways to handle several pollutants produced during the machining process. The book is useful on both undergraduate and postgraduate levels and it is of interest to all those working with manufacturing and machining technology.

  8. 小模数齿轮单面啮合测量机测控软件设计%Design of Test and Control Software of Measuring Machine based on Single- flank Testing for Fine- pitch Gears

    Institute of Scientific and Technical Information of China (English)

    张万年; 石照耀

    2011-01-01

    基于Visual C++设计了小模数齿轮单面啮合测量机测控软件.采用圆光栅编码器实现两路角度测量,微位移传感器实现微角度测量,ACR9000控制器实现伺服电机控制,PCI1784数字计数卡实现数据采集.测控软件具有齿轮和电机参数输入、电气控制、自动测量、数据采集、偏差计算、测量结果动态显示和保存、报表打印等功能.测试结果表明该软件功能稳定可靠,人机界面友好,操作方便,可测量小模数齿轮传动误差.%A test and control software of the measuring machine based on single- flank testing for fine- pitch gears is programmed based on Visual C ++ . Two circular gratings are used to measure the angle of spindles, a capacitance displacement sensor is used to measure micro- displacement, a motion controller of ACR9000 is used to control dual - motor synchronous drive, and a data acquisition card of PCI 1784 is used to acquire data. Main functions of the software include parameter inputting, electric control, automatic measuring, data acquisition, deviation calculation,results saving, and inspection report and print. In addition, the inspection results indicate that the software has high stability, friendly man - machine interface and operating convenience. It can be applied to inspect the transmission error of fine- pitch gears.

  9. ELEFUNT test results under AST Fortran V1. 8. 0 on the Sequent Symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Cody, W.J.

    1990-07-01

    This report discusses testing of the floating-point arithmetic and of the elementary function libraries under AST Fortran on a 24-processor Sequent Symmetry computer. The programs MACHAR and PARANOIA were used to check the quality of arithmetic, and the ELEFUNT suite of programs from the book Software Manual for the Elementary Functions by Cody and Waite was used to check function performance. Two complete sets of tests were run, one for each type of floating-point processor, Intel 80387 and Weitek 1167, on the machine. 11 refs., 4 tabs.

  10. Polishing tool and the resulting TIF for three variable machine parameters as input for the removal simulation

    Science.gov (United States)

    Schneider, Robert; Haberl, Alexander; Rascher, Rolf

    2017-06-01

    The trend in the optic industry shows, that it is increasingly important to be able to manufacture complex lens geometries on a high level of precision. From a certain limit on the required shape accuracy of optical workpieces, the processing is changed from the two-dimensional to point-shaped processing. It is very important that the process is as stable as possible during the in point-shaped processing. To ensure stability, usually only one process parameter is varied during processing. It is common that this parameter is the feed rate, which corresponds to the dwell time. In the research project ArenA-FOi (Application-oriented analysis of resource-saving and energy-efficient design of industrial facilities for the optical industry), a touching procedure is used in the point-attack, and in this case a close look is made as to whether a change of several process parameters is meaningful during a processing. The ADAPT tool in size R20 from Satisloh AG is used, which is also available for purchase. The behavior of the tool is tested under constant conditions in the MCP 250 CNC by OptoTech GmbH. A series of experiments should enable the TIF (tool influence function) to be determined using three variable parameters. Furthermore, the maximum error frequency that can be processed is calculated as an example for one parameter set and serves as an outlook for further investigations. The test results serve as the basic for the later removal simulation, which must be able to deal with a variable TIF. This topic has already been successfully implemented in another research project of the Institute for Precision Manufacturing and High-Frequency Technology (IPH) and thus this algorithm can be used. The next step is the useful implementation of the collected knowledge. The TIF must be selected on the basis of the measured data. It is important to know the error frequencies to select the optimal TIF. Thus, it is possible to compare the simulated results with real measurement

  11. Hydrogeology and results of injection tests at waste-injection test sites in Pinellas County, Florida

    Science.gov (United States)

    Hickey, John J.

    1982-01-01

    Potential benefits or hazards to freshwater resources could result from subsurface injection of treated wastewater. Recognizing this, the U.S. Geological Survey, in cooperation with Pinellas County and the city of St. Petersburg, undertook an evaluation of the hydrogeology and injection of wastewater at proposed test sites on the Pinellas peninsula. The injection sites are underlain by sedimentary rocks ranging in age from Cretaceous to Pleistocene. Lower Eocene carbonate rocks were penetrated to a maximum depth of 3,504 feet and were found to have relatively low water yields. The most permeable part of the investigated section was in rocks of middle Eocene age within the Floridan aquifer. At the injection sites, the Floridan aquifer was subdivided into four permeable zones and three semiconfining beds. The test injection zone is within the Avon Park Limestone, the most productive of the identified permeable zones, with a transmissivity of about 1,000,000 feet squared per day. Two semiconfining beds are above the injection zone in the Suwannee Limestone and Ocala Limestone and have vertical hydraulic conductivities estimated to range from about 0.1 to 1 foot per day where these beds do not contain clay. Limited fresh ground-water supplies exist in the Floridan aquifer within the Pinellas peninsula. At all test sites, chloride concentration in the injection zone ranged from 19,000 to 20,000 milligrams per liter. Injection tests ranging in duration from 3 to 91.1 days were run at three different sites. Pressure buildup occurred in permeable zones above and below the injection zone during these tests. Calculated pressure buildup in observation wells close to and at some distance from the test wells was typically less than 1 pound per square inch. Injection and formation water will probably move slowly through the semiconfining bed overlying the injection zone, and long-term injection tests will be needed to determine the effectiveness of these beds to retard flow. The

  12. Autonomous Airborne Refueling Demonstration: Phase I Flight-Test Results

    Science.gov (United States)

    Dibley, Ryan P.; Allen, Michael J.; Nabaa, Nassib

    2007-01-01

    The first phase of the Autonomous Airborne Refueling Demonstration (AARD) project was completed on August 30, 2006. The goal of this 15-month effort was to develop and flight-test a system to demonstrate an autonomous refueling engagement using the Navy style hose-and-drogue air-to-air refueling method. The prime contractor for this Defense Advanced Research Projects Agency (DARPA) sponsored program was Sierra Nevada Corporation (SNC), Sparks, Nevada. The responsible flight-test organization was the National Aeronautics and Space Administration (NASA) Dryden Flight Research Center (DFRC), Edwards, California, which also provided the F/A-18 receiver airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois). The B-707-300 tanker airplane (The Boeing Company) was contracted through Omega Aerial Refueling Services, Inc., Alexandria, Virginia, and the optical tracking system was contracted through OCTEC Ltd., Bracknell, Berkshire, United Kingdom. Nine research flights were flown, testing the functionality and performance of the system in a stepwise manner, culminating in the plug attempts on the final flight. Relative position keeping was found to be very stable and accurate. The receiver aircraft was capable of following the tanker aircraft through turns while maintaining its relative position. During the last flight, six capture attempts were made, two of which were successful. The four misses demonstrated excellent characteristics, the receiver retreating from the drogue in a controlled, safe, and predictable manner that precluded contact between the drogue and the receiver aircraft. The position of the receiver aircraft when engaged and in position for refueling was found to be 5.5 to 8.5 ft low of the ideal position. The controller inputs to the F/A-18 were found to be extremely small.

  13. Autonomous Airborne Refueling Demonstration, Phase I Flight-Test Results

    Science.gov (United States)

    Dibley, Ryan P.; Allen, Michael J.; Nabaa, Nassib

    2007-01-01

    The first phase of the Autonomous Airborne Refueling Demonstration (AARD) project was completed on August 30, 2006. The goal of this 15-month effort was to develop and flight-test a system to demonstrate an autonomous refueling engagement using the Navy style hose-and-drogue air-to-air refueling method. The prime contractor for this Defense Advanced Research Projects Agency (DARPA) sponsored program was Sierra Nevada Corporation (SNC), Sparks, Nevada. The responsible flight-test organization was the NASA Dryden Flight Research Center (DFRC), Edwards, California, which also provided the F/A-18 receiver airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois). The B-707-300 tanker airplane (The Boeing Company) was contracted through Omega Aerial Refueling Services, Inc., Alexandria, Virginia, and the optical tracking system was contracted through OCTEC Ltd., Bracknell, Berkshire, United Kingdom. Nine research flights were flown, testing the functionality and performance of the system in a stepwise manner, culminating in the plug attempts on the final flight. Relative position keeping was found to be very stable and accurate. The receiver aircraft was capable of following the tanker aircraft through turns while maintaining its relative position. During the last flight, six capture attempts were made, two of which were successful. The four misses demonstrated excellent characteristics, the receiver retreating from the drogue in a controlled, safe, and predictable manner that precluded contact between the drogue and the receiver aircraft. The position of the receiver aircraft when engaged and in position for refueling was found to be 5.5 to 8.5 ft low of the ideal position. The controller inputs to the F/A-18 were found to be extremely small

  14. 开尔文四线测试方式在PCB测试机中的应用%The Application of the Kelvin Four-Wire Testing Method in PCB Testing Machine

    Institute of Scientific and Technical Information of China (English)

    刘懿俊

    2013-01-01

    分析了PCB测试机中的普通二线式测试原理、开尔文(Kelvin)四线测量方法原理,介绍了开尔文四线测量方法的优点。%This report aimed to analyze the two-wire and four-wire kelvin measurement principle in PCB testing machine , discused the advantage of Kelvin Four-Wire Testing method in PCB testing.

  15. AiResearch QCGAT engine: Acoustic test results

    Science.gov (United States)

    Kisner, L. S.

    1980-01-01

    The noise levels of the quiet, general aviation turbofan (QCGAT) engine were measured in ground static noise tests. The static noise levels were found to be markedly lower than the demonstrably quiet AiResearch model TFE731 engine. The measured QCGAT noise levels were correlated with analytical noise source predictions to derive free-field component noise predictions. These component noise sources were used to predict the QCGAT flyover noise levels at FAR Part 36 conditions. The predicted flyover noise levels are about 10 decibels lower than the current quietest business jets.

  16. GPM Avionics Module Heat Pipes Design and Performance Test Results

    Science.gov (United States)

    Ottenstein, Laura; DeChristopher, Mike

    2012-01-01

    GPM is a satellite constellation to study precipitation formed from a partnership between NASA and the Japanese Aerospace Exploration Agency (JAXA). The GPM Core Observatory, being developed and tested at GSFC, serves as a reference standard to unify precipitation measurements from the GPM satellite constellation. The Core Observatory carries an advanced radar/radiometer system to measure precipitation from space. The scientific data gained from GPM will benefit both NASA and JAXA by advancing our understanding of Earth's water and energy cycle, improving forecasts of extreme weather events, and extending our current capabilities in using accurate and timely precipitation information to benefit society.

  17. Field Test: Results from the One Year Mission

    Science.gov (United States)

    Reschke, M. F.; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskaya, E. S.; Cerisano, J. M.; Rosenberg, M. J. F.; Bloomberg, J. J.; Stenger, M. B.; Lee, S. M. C.; Laurie, S. S.; Rukavishnikov, I. V.; Fomina, E. V.; Wood, S. J.; Mulavara, A. P.; Feiveson, A. H.; Fisher, E. A.; Phillips, T.; Ribeiro, C.; Taylor, L. C.; Miller, C. A.; Gadd, N. E.; Peters, B. T.; Kitov, V. V.; Lysova, N. Yu; Holden, K. L.; De Dios, Y.

    2017-01-01

    The One Year Mission was designed to aid in determining the effect that extending the duration on orbit aboard the International Space Station (ISS) would have on a number of biological and physiological systems. Two crewmembers were selected to participate in this endeavor, one U.S. On-Orbit Segment (USOS) astronaut and one Russian cosmonaut. The Neuroscience and Cardiovascular and Vision Laboratories at the Johnson Space Center and the Sensory-Motor and Countermeasures Division within the Institute for Biomedical Problems were selected to investigate vestibular, sensorimotor and cardiovascular function with the two long-duration crewmembers using the established methodology developed for the Field Test (FT).

  18. Short-Term Test Results: Multifamily Home Energy Efficiency Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, J.

    2013-01-01

    Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. The Bay Ridge project is comprised of a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). The base scope has been applied to the entire complex, except for one 12-unit building which underwent the DER scope. Findings from the implementation, commissioning, and short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach. Despite being a moderate rehab instead of a gut rehab, the Bay Ridge DER is currently projected to achieve energy savings ≥ 50% compared to pre-retrofit, and the short-term testing supports this estimate.

  19. Hanford 100-D Area Biostimulation Treatability Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J.; Vermeul, Vincent R.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Elmore, Rebecca P.; Mitroshkov, Alexandre V.; Sklarew, Deborah S.; Johnson, Christian D.; Oostrom, Martinus; Newcomer, Darrell R.; Brockman, Fred J.; Bilskis, Christina L.; Hubbard, Susan S.; Peterson, John E.; Williams, Kenneth H.; Gasperikova, E.; Ajo-Franklin, J.

    2009-09-30

    Pacific Northwest National Laboratory conducted a treatability test designed to demonstrate that in situ biostimulation can be applied to help meet cleanup goals in the Hanford Site 100-D Area. In situ biostimulation has been extensively researched and applied for aquifer remediation over the last 20 years for various contaminants. In situ biostimulation, in the context of this project, is the process of amending an aquifer with a substrate that induces growth and/or activity of indigenous bacteria for the purpose of inducing a desired reaction. For application at the 100-D Area, the purpose of biostimulation is to induce reduction of chromate, nitrate, and oxygen to remove these compounds from the groundwater. The in situ biostimulation technology is intended to provide supplemental treatment upgradient of the In Situ Redox Manipulation (ISRM) barrier previously installed in the Hanford 100-D Area and thereby increase the longevity of the ISRM barrier. Substrates for the treatability test were selected to provide information about two general approaches for establishing and maintaining an in situ permeable reactive barrier based on biological reactions, i.e., a biobarrier. These approaches included 1) use of a soluble (miscible) substrate that is relatively easy to distribute over a large areal extent, is inexpensive, and is expected to have moderate longevity; and 2) use of an immiscible substrate that can be distributed over a reasonable areal extent at a moderate cost and is expected to have increased longevity.

  20. Short-Term Test Results: Multifamily Home Energy Efficiency Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, J.

    2013-01-01

    Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. The Bay Ridge project is comprised of a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). The base scope has been applied to the entire complex, except for one 12-unit building which underwent the DER scope. Findings from the implementation, commissioning, and short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach. Despite being a moderate rehab instead of a gut rehab, the Bay Ridge DER is currently projected to achieve energy savings ≥ 50% compared to pre-retrofit, and the short-term testing supports this estimate.