WorldWideScience

Sample records for lysholm positive displacement

  1. Análise do protocolo funcional de Lysholm modificado em pacientes com joelhos normais Analysis on the modified Lysholm functional protocol among patients with normal knees

    Directory of Open Access Journals (Sweden)

    Rodrigo Pires e Albuquerque

    2011-01-01

    Full Text Available OBJETIVO: Avaliar o protocolo de Lysholm modificado em pacientes com joelhos considerados normais (sem queixas ou doenças prévias nessa região. MÉTODO: No período de janeiro a março de 2010, foi realizado um estudo prospectivo com 300 pacientes que compareceram à emergência de nosso hospital com queixas ortopédicas em outras regiões do corpo. O critério de inclusão dos pacientes foi ausência de queixas ou cirurgia prévia no joelho considerado dominante. O limite de idade foi entre 16 e 40 anos, com média de 28,8 anos. Nossa pesquisa foi composta de 153 pacientes do sexo masculino e 147 pacientes do sexo feminino. No sistema Lysholm a pontuação máxima é de 100 pontos e inclui critérios funcionais e objetivos. Ao todo, 50% do total do escore é baseado nos sintomas de dor e instabilidade. RESULTADOS: A média do protocolo de Lysholm foi de 95 pontos em joelhos considerados normais. O sexo masculino obteve um escore superior quando comparado ao sexo feminino. CONCLUSÃO: Os pacientes com joelho considerado normal não obtiveram a pontuação máxima na avaliação pelo protocolo modificado de Lysholm. O estudo sugere que esta linha de pesquisa sobre o sistema de avaliação funcional do joelho encontra-se aberta para novas avaliações. Assim como também devemos pesquisar a criação e a elaboração de novos formulários de avaliação funcional do joelho para a obtenção de um consenso mundial.OBJECTIVE: To evaluate the modified Lysholm protocol among patients with knees that were considered to be normal (without previous complaints or pathological conditions in this region. METHOD: Between January 2010 and March 2010, a prospective study was conducted on 300 patients with orthopedic complaints in other regions of the body who came to the emergency service of our hospital. The inclusion criterion among these patients was the absence of complaints or previous surgery in the knee that was considered to be dominant. The age

  2. Questionário específico para sintomas do joelho "Lysholm Knee Scoring Scale": tradução e validação para a língua portuguesa Specific questionnaire for knee symptoms - the "Lysholm Knee Scoring Scale": translation and validation into Portuguese

    Directory of Open Access Journals (Sweden)

    Maria Stella Peccin

    2006-01-01

    Full Text Available As doenças do joelho apresentam conseqüências variadas para a função e a qualidade de vida do indivíduo. Para traduzir, validar e verificar as propriedades de medida do questionário específico para sintomas do joelho "Lysholm Knee Scoring Scale" para a língua portuguesa, selecionamos, por conveniência, 50 pacientes (29 homens e 21 mulheres, média de idade 38,7 anos com lesão de joelho (lesão meniscal, lesão do ligamento cruzado anterior, condromalácia ou artrose. A reprodutibilidade e a concordância ordinal inter e intra-entrevistador foram excelentes (alfa = 0,9. A concordância nominal inter-entrevistadores foi boa (Kappa = 0,7 e intra-entrevistador, excelente (Kappa = 0,8. No processo de validação, correlacionamos o questionário Lysholm com a escala numérica da dor (r=-0,6; p=0,001 e com o índice de Lequesne (r= -0,8; p=0,001. As correlações entre o Lysholm e a avaliação global da saúde pelo paciente e pelo terapeuta apresentaram-se fracas e não significantes. As correlações entre o questionário Lysholm e o SF-36 foram significantes nos aspectos físicos (r = 0,4; p = 0,04, de dor (r = 0,5; p = 0,001 e de capacidade funcional (r = 0,7; p = 0,0001. Concluímos que a tradução e adaptação cultural do "Lysholm knee scoring scale" para o nosso idioma apresentou reprodutibilidade e validade em pacientes com lesão meniscal, lesão do ligamento cruzado anterior, condromalácia ou artrose do joelho.Knee diseases present variable consequences for an individual’s function and quality of life. For the purposes of translating, validating and checking the measurement properties of the specific questionnaire for knee symptoms - the "Lysholm Knee Scoring Scale" - into Portuguese, we selected, for convenience, 50 patients (29 males and 21 females, mean age = 38.7 years with knee injuries (meniscal injury, anterior cruciate ligament injury, chondromalacia or arthrosis. Reproducibility and ordinal consistency inter- and

  3. Linearization of Positional Response Curve of a Fiber-optic Displacement Sensor

    Science.gov (United States)

    Babaev, O. G.; Matyunin, S. A.; Paranin, V. D.

    2018-01-01

    Currently, the creation of optical measuring instruments and sensors for measuring linear displacement is one of the most relevant problems in the area of instrumentation. Fiber-optic contactless sensors based on the magneto-optical effect are of special interest. They are essentially contactless, non-electrical and have a closed optical channel not subject to contamination. The main problem of this type of sensors is the non-linearity of their positional response curve due to the hyperbolic nature of the magnetic field intensity variation induced by moving the magnetic source mounted on the controlled object relative to the sensing element. This paper discusses an algorithmic method of linearizing the positional response curve of fiber-optic displacement sensors in any selected range of the displacements to be measured. The method is divided into two stages: 1 - definition of the calibration function, 2 - measurement and linearization of the positional response curve (including its temperature stabilization). The algorithm under consideration significantly reduces the number of points of the calibration function, which is essential for the calibration of temperature dependence, due to the use of the points that randomly deviate from the grid points with uniform spacing. Subsequent interpolation of the deviating points and piecewise linear-plane approximation of the calibration function reduces the microcontroller storage capacity for storing the calibration function and the time required to process the measurement results. The paper also presents experimental results of testing real samples of fiber-optic displacement sensors.

  4. The description of condyle position in disc displacement with reduction using Cone Beam Computed Tomography 3D radiographic analysis

    Directory of Open Access Journals (Sweden)

    Liana Rahmayani

    2009-07-01

    Full Text Available One of the temporomandibular joint disorders that mostly occurs is disc displacement with reduction. Disc displacement that causes the displacement of condyle position can be evaluated by using radiograph. The Cone Beam Computed Tomography (CBCT-3D is a radiograph equipment which is able to capture the condyle position from many directions. This research was aimed to see the condyle position in patients with disc displacement with reduction symptoms. This research was conducted to 11 patients with symptoms of disc displacement with reduction and 3 patients without symptoms of disc displacement with reduction as the counterpart. What was conducted to the sample was the radiographic imaging using CBCT-3D radiography, followed by measuring the joint space distance in the sagittal and coronal directions. The result of the research was analyzed using the T-test. Statistically, the result of the test showed a significant difference ( = 0.05 between patients with disc displacement with reduction symptoms and the patients without symptoms, in sagittal and coronal views. The conclusion led to the difference in condyle positions in patients with the disc displacement with reduction and patients without the symptoms which meant there was a condyle position displacement that caused the distance alteration in joint space in sagittal and coronal directions.

  5. Staff technical position on investigations to identify fault displacement hazards and seismic hazards at a geologic repository

    International Nuclear Information System (INIS)

    McConnell, K.I.; Blackford, M.E.; Ibrahim, A.K.

    1992-07-01

    The purpose of this Staff Technical Position (STP) is to provide guidance to the US Department of Energy (DOE) on acceptable geologic repository investigations that can be used to identify fault displacement hazards and seismic hazards. ne staff considers that the approach this STP takes to investigations of fault displacement and seismic phenomena is appropriate for the collection of sufficient data for input to analyses of fault displacement hazards and seismic hazards, both for the preclosure and postclosure performance periods. However, detailed analyses of fault displacement and seismic data, such as those required for comprehensive assessments of repository performance, may identify the need for additional investigations. Section 2.0 of this STP describes the 10 CFR Part 60 requirements that form the basis for investigations to describe fault displacement hazards and seismic hazards at a geologic repository. Technical position statements and corresponding discussions are presented in Sections 3.0 and 4.0, respectively. Technical position topics in this STP are categorized thusly: (1) investigation considerations, (2) investigations for fault-displacement hazards, and (3) investigations for seismic hazards

  6. Electromagnetic Tracking of Intrafraction Prostate Displacement in Patients Externally Immobilized in the Prone Position

    International Nuclear Information System (INIS)

    Bittner, Nathan; Butler, Wayne M.; Reed, Joshua L.; Murray, Brian C.; Kurko, Brian S.; Wallner, Kent E.; Merrick, Gregory S.

    2010-01-01

    Purpose: To evaluate intrafraction prostate displacement among patients immobilized in the prone position using real-time monitoring of implanted radiofrequency transponders. Methods and Materials: The Calypso localization system was used to track prostate motion in patients receiving external beam radiation therapy (XRT) for prostate cancer. All patients were treated in the prone position and immobilized with a thermoplastic immobilization device. Real-time measurement of prostate displacement was recorded for each treatment fraction. These measurements were used to determine the duration and magnitude of displacement along the three directional axes. Results: The calculated centroid of the implanted transponders was offset from the treatment isocenter by ≥2 mm, ≥3 mm, and ≥4 mm for 38.0%, 13.9%, and 4.5% of the time. In the lateral dimension, the centroid was offset from the treatment isocenter by ≥2 mm, ≥3 mm, and ≥4 mm for 2.7%, 0.4%, and 0.06% of the time. In the superior-inferior dimension, the centroid was offset from the treatment isocenter by ≥2 mm, ≥3 mm, and ≥4 mm for 16.1%, 4.7%, and 1.5% of the time, respectively. In the anterior-posterior dimension, the centroid was offset from the treatment isocenter by ≥2 mm, ≥3 mm, and ≥4 mm for 13.4%, 3.0%, and 0.5% of the time. Conclusions: Intrafraction prostate displacement in the prone position is comparable to that in the supine position. For patients with large girth, in whom the supine position may preclude accurate detection of implanted radiofrequency transponders, treatment in the prone position is a suitable alternative.

  7. Visible imaging measurement of position and displacement of the last closed flux surface in EAST tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y.F. [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Xu, G.S., E-mail: gsxu@ipp.ac.cn [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Li, Y.L.; Yang, J.H.; Yan, N.; Liu, L.; Yuan, S.; Luo, Z.P. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Sang, C.F. [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China); Gu, S.; Xu, J.C.; Hu, G.H.; Wang, Y.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Peng, Y.K.M.; Wan, B.N. [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2017-06-15

    Highlights: • A new method for measuring the position and displacement of the LCFS has been developed in EAST tokamak. • This method is based on the visible imaging diagnostic and shown to be an effective and convenient approach. • This method can be applied to measure displacements of the LCFS during application of resonant magnetic perturbation fields. - Abstract: A new method for measuring the position and displacement of the last closed flux surface (LCFS) with visible imaging diagnostics has been developed in EAST. By measuring the relative intensity profiles of the green visible Li-II emission in the tangential planes of the optical systems, it is possible to infer the positions of certain points on the LCFS. This emission line is readily available in discharges with Li-coating wall routinely employed to improve the plasma performance. We describe the measuring method, giving results which are compared with those obtained by EFIT, and showing this as an effective and convenient approach to determine the position of the LCFS. This method is further applied to measure the displacements of the LCFS during application of resonant magnetic perturbation fields in the EAST tokamak.

  8. A review on bridge dynamic displacement monitoring using global positioning system and accelerometer

    Science.gov (United States)

    Yunus, Mohd Zulkifli Mohd; Ibrahim, Nuremira; Ahmad, Fatimah Shafinaz

    2018-02-01

    This paper reviews previous research on bridge dynamic displacement monitoring using Global Positioning System (GPS) and an accelerometer for Structural Health Monitoring (SHM) of bridge. These include the review of the advantages and disadvantages of the measurement as well as the methodology of the measurements used in the recent research study. This review could provide a preliminary decision overview for students or researchers before initiating a research related to the bridge dynamic displacement monitoring.

  9. Impact of ultrasound probe pressure on uterine positional displacement in gynecologic cancer patients

    DEFF Research Database (Denmark)

    Baker, Mariwan; Juhler-Nøttrup, Trine; Behrens, Claus F.

    2014-01-01

    Aim: The aim of this study was to quantify the uterine positional displacement induced by ultrasound probe pressure on a phantom and address the daily uterine motion in a healthy volunteer. Materials & methods: The phantom mimics the female pelvic region. The incorporated organs were subjected to...

  10. Staff Technical Position on consideration of fault displacement hazards in geologic repository design

    International Nuclear Information System (INIS)

    McConnell, K.I.; Lee, M.P.

    1994-09-01

    Nuclear Regulatory Commission regulations for the disposal of spent nuclear fuel and high-level radioactive waste in a geologic repository recognize that fault displacement is a potentially adverse condition. However, they do not prohibit designing the geologic repository against the effects of such a potentially adverse condition. This Staff Technical Position recognizes the acceptability of designing the geologic repository to take into account the attendant effects (e.g., displacement) of faults of regulatory concern and expresses the staff's views on what is needed from the US Department of Energy if it chooses to locate structures, systems, and components important to safety or important to waste isolation in areas that contain faults of regulatory concern

  11. Detecting Output Pressure Change of Positive-Displacement Pump by Phase Trajectory Method

    Directory of Open Access Journals (Sweden)

    Jerzy Stojek

    2010-06-01

    Full Text Available The monitoring of hydraulic system condition change during its exploitation ran its complex problem. The main task is to identifyearly phase damage of hydraulic system elements (pumps, valves, ect. in order to take decision which can avoid hydraulic system breakdown. This paper presents the possibility of phase trajectories use in detecting output pressure change of hydraulic system causedby positive-displacement pump wear.

  12. Position displacement effect on the doses in the peripheral head regions

    International Nuclear Information System (INIS)

    Kortesniemi, M.; Seppaelae, T.; Bjugg, H.; Seren, T.; Kotiluoto, P.; Auterinen, I.; Parkkinen, R.; Savolainen, S.

    2000-01-01

    Patient positioning is a challenging task in BNCT-treatments due to the use of multiple fields and a static horizontal beam construction. Positioning accuracy of 5 mm is required for acceptable dose delivery within appropriate limits of dose uncertainty (up to 10% of point dose in target volume). The aim of this study was to determine if a patient head position creating a clear gap between the beam port and the head would have a significant effect on the doses to the peripheral regions of the head, e.g. to the eyes. The gamma dose rates were measured in a water filled ellipsoidal phantom with an ionisation chamber (IC). Mn activation wires were used to determine the Mn-55(n, γ) reaction rates. Twelve measurement points were chosen in the phantom and two phantom positions were applied. According to this study the 35 mm position change and the resulting gap has an obvious effect on the peripheral doses in BNCT. The Mn activation reaction rates were on the average 80% higher in the deviation position than in the reference position. Increasing depth from the surface inside the phantom diminished the gamma dose difference between the two positions. Scattering environment changes with position displacement and resulting gap causes differences in neutron fluences and gamma doses. (author)

  13. Displaced squeezed number states: Position space representation, inner product, and some applications

    DEFF Research Database (Denmark)

    Møller, Klaus Braagaard; Jørgensen, Thomas Godsk; Dahl, Jens Peder

    1996-01-01

    For some applications the overall phase of a quantum state is crucial. For the so-called displaced squeezed number state (DSN), which is a generalization of the well-known squeezed coherent state, we obtain the position space representation with the correct overall phase, from the dynamics...... in a harmonic potential. The importance of the overall phase is demonstrated in the context of characteristic or moment generating functions. For two special cases the characteristic function is shown to be computable from the inner product of two different DSNs....

  14. Evaluation and prediction of the performance of positive displacement motor

    Energy Technology Data Exchange (ETDEWEB)

    Tudor, R.; Ginzburg, L. [Canadian Fracmaster Ltd., Calgary, AB (Canada); Xu, H. [Japan National Oil Corp (Japan); Li, J.; Robello, G.; Grigor, C.

    1998-12-31

    Test results of positive displacement motors (PDMs) collected by using various PDMs from a number of different suppliers have been analyzed. Various correlations have been developed and motor performance pumped with incompressible drilling fluid was evaluated based on test data provided by suppliers in the form of pressure drop versus torque output. Conclusions drawn from the study suggest that when a motor is operated at less than full load, the correlation between mechanical power and hydraulic power across the PDM power section can be described with a simple linear equation (different for each PDM type). Assuming the availability of patented geometric information for each PDM type, the performance of PDMs can be described by both the geometric parameters of the motor and the rheological properties of the circulation fluid. 9 refs., 8 figs.

  15. Prediction of lung tumour position based on spirometry and on abdominal displacement: Accuracy and reproducibility

    International Nuclear Information System (INIS)

    Hoisak, Jeremy D.P.; Sixel, Katharina E.; Tirona, Romeo; Cheung, Patrick C.F.; Pignol, Jean-Philippe

    2006-01-01

    Background and purpose: A simulation investigating the accuracy and reproducibility of a tumour motion prediction model over clinical time frames is presented. The model is formed from surrogate and tumour motion measurements, and used to predict the future position of the tumour from surrogate measurements alone. Patients and methods: Data were acquired from five non-small cell lung cancer patients, on 3 days. Measurements of respiratory volume by spirometry and abdominal displacement by a real-time position tracking system were acquired simultaneously with X-ray fluoroscopy measurements of superior-inferior tumour displacement. A model of tumour motion was established and used to predict future tumour position, based on surrogate input data. The calculated position was compared against true tumour motion as seen on fluoroscopy. Three different imaging strategies, pre-treatment, pre-fraction and intrafractional imaging, were employed in establishing the fitting parameters of the prediction model. The impact of each imaging strategy upon accuracy and reproducibility was quantified. Results: When establishing the predictive model using pre-treatment imaging, four of five patients exhibited poor interfractional reproducibility for either surrogate in subsequent sessions. Simulating the formulation of the predictive model prior to each fraction resulted in improved interfractional reproducibility. The accuracy of the prediction model was only improved in one of five patients when intrafractional imaging was used. Conclusions: Employing a prediction model established from measurements acquired at planning resulted in localization errors. Pre-fractional imaging improved the accuracy and reproducibility of the prediction model. Intrafractional imaging was of less value, suggesting that the accuracy limit of a surrogate-based prediction model is reached with once-daily imaging

  16. A high accuracy algorithm of displacement measurement for a micro-positioning stage

    Directory of Open Access Journals (Sweden)

    Xiang Zhang

    2017-05-01

    Full Text Available A high accuracy displacement measurement algorithm for a two degrees of freedom compliant precision micro-positioning stage is proposed based on the computer micro-vision technique. The algorithm consists of an integer-pixel and a subpixel matching procedure. Series of simulations are conducted to verify the proposed method. The results show that the proposed algorithm possesses the advantages of high precision and stability, the resolution can attain to 0.01 pixel theoretically. In addition, the consuming time is reduced about 6.7 times compared with the classical normalized cross correlation algorithm. To validate the practical performance of the proposed algorithm, a laser interferometer measurement system (LIMS is built up. The experimental results demonstrate that the algorithm has better adaptability than that of the LIMS.

  17. MR image findings on advanced internal derangement of the temporomandibular joints. Cases of disc position changed from anterior disc displacement with reduction to without reduction

    International Nuclear Information System (INIS)

    Igarashi, Chinami; Kobayashi, Kaoru; Yuasa, Masao; Imanaka, Masahiro; Yamamoto, Akira

    2005-01-01

    This study was designed to evaluate the suggestion that the clinical findings and MR image findings of anterior disc displacement with reduction cases could not reduce the disc displacement within the follow-up period. We selected 26 joints without remarkable bone changes in the condylar head or glenoid fossa in which reduction disappeared during follow-up. Clinical evaluation focused on temporomandibular pain, trismus, and joint sound. MR imaging was targeted for configuration of articular disc, degree of disc displacement, and condylar head position. Clinical signs observed with progression of the condition were disappearance of joint sound in 12/26 joints (46.1%), temporomandibular pain in 15/26 joints (57.6%), and decreased distance of opening mouth in 19/26 joints (73%). MR image findings were disc configuration changes in 12/26 joints (46.1%), increased degree of anterior displacement of disc in 20/26 joints (76.9%), and condylar head position changes in 9/26 joints (34.6%). It is suggested that the advanced stage of internal derangement is closely associated with the degree of disc displacement. (author)

  18. Optoelectronic device for the measurement of the absolute linear position in the micrometric displacement range

    Science.gov (United States)

    Morlanes, Tomas; de la Pena, Jose L.; Sanchez-Brea, Luis M.; Alonso, Jose; Crespo, Daniel; Saez-Landete, Jose B.; Bernabeu, Eusebio

    2005-07-01

    In this work, an optoelectronic device that provides the absolute position of a measurement element with respect to a pattern scale upon switch-on is presented. That means that there is not a need to perform any kind of transversal displacement after the startup of the system. The optoelectronic device is based on the process of light propagation passing through a slit. A light source with a definite size guarantees the relation of distances between the different elements that constitute our system and allows getting a particular optical intensity profile that can be measured by an electronic post-processing device providing the absolute location of the system with a resolution of 1 micron. The accuracy of this measuring device is restricted to the same limitations of any incremental position optical encoder.

  19. Validation of a CFD methodology for positive displacement LVAD analysis using PIV data.

    Science.gov (United States)

    Medvitz, Richard B; Reddy, Varun; Deutsch, Steve; Manning, Keefe B; Paterson, Eric G

    2009-11-01

    Computational fluid dynamics (CFD) is used to asses the hydrodynamic performance of a positive displacement left ventricular assist device. The computational model uses implicit large eddy simulation direct resolution of the chamber compression and modeled valve closure to reproduce the in vitro results. The computations are validated through comparisons with experimental particle image velocimetry (PIV) data. Qualitative comparisons of flow patterns, velocity fields, and wall-shear rates demonstrate a high level of agreement between the computations and experiments. Quantitatively, the PIV and CFD show similar probed velocity histories, closely matching jet velocities and comparable wall-strain rates. Overall, it has been shown that CFD can provide detailed flow field and wall-strain rate data, which is important in evaluating blood pump performance.

  20. Effects of neuromuscular training on knee joint stability after anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Shim, Jae-Kwang; Choi, Ho-Suk; Shin, Jun-Ho

    2015-12-01

    [Purpose] This study examined the effects of neuromuscular training on knee joint stability after anterior cruciate ligament reconstruction. [Subjects and Methods] The subjects were 16 adults who underwent arthroscopic anterior cruciate reconstruction and neuromuscular training. The Lysholm scale was used to assess functional disorders on the affected knee joint. A KT-2000 arthrometer was used to measure anterior displacement of the tibia against the femur. Surface electromyography was used to detect the muscle activation of the vastus medialis oblique, vastus lateralis, biceps femoris, and semitendinosus before and after neuromuscular training. [Results] There was significant relaxation in tibial anterior displacement of the affected and sound sides in the supine position before neuromuscular training. Furthermore, the difference in the tibial anterior displacement of the affected knee joints in the standing position was reduced after neuromuscular training. Moreover, the variation of the muscle activation evoked higher muscle activation of the vastus medialis oblique, vastus lateralis, biceps femoris, and semitendinosus. [Conclusion] Neuromuscular training may improve functional joint stability in patients with orthopedic musculoskeletal injuries in the postoperative period.

  1. Thermal effect of lubricating oil in positive-displacement air compressors

    International Nuclear Information System (INIS)

    Valenti, Gianluca; Colombo, Luigi; Murgia, Stefano; Lucchini, Andrea; Sampietro, Andrea; Capoferri, Andrea; Araneo, Lucio

    2013-01-01

    The isentropic efficiency of positive-displacement compressors may be improved in order to follow an increasing demand for energy savings. This work analyzes the thermal effect of the lubricating oil presence in the air during compression with the scope of exploiting it as a thermal ballast to mitigate both the gas temperature rise and its compression work. The bibliographic review shows that other authors suggested that oil can have positive effects if properly injected. Here an energy balance analysis is executed with the scope of deriving relations for the gas–liquid compression in analogy with those typical for the gas-only compression and of confirming that ideally the liquid presence may have beneficial effects, making the gas–liquid compression even better than 1- and 2-time intercooled gas compressions. Given these positive results, a heat transfer analysis is conducted to model the thermal interaction between gas and oil droplets within a mid-size rotary vane air compressor. A droplet diameter of the order of 100 μm leads to large reductions of both temperature increase and compression work: air can exit the discharge port at a temperature as low as 60 °C and compression work can be lowered by 23–28% with respect to conventional compressors. Finally, a test rig is constructed and operated to investigate a large-flow and large-angle oil nozzle taken from the market showing that, at the operating conditions of a compressor, oil breaks up into small droplets and undefined structures with large exchange surfaces. -- Highlights: ► Exploitation of thermal effect of oil in gas compressors is assessed numerically. ► Oil in 100 μm-diameter droplets mitigates effectively the gas temperature rise. ► Discharge temperature and compression work result to be much smaller than typical. ► An experimental setup is used to investigate oil atomization via commercial nozzles. ► A tested nozzle creates fine oil droplets and structures at conditions of

  2. A robust rotation-invariance displacement measurement method for a micro-/nano-positioning system

    Science.gov (United States)

    Zhang, Xiang; Zhang, Xianmin; Wu, Heng; Li, Hai; Gan, Jinqiang

    2018-05-01

    A robust and high-precision displacement measurement method for a compliant mechanism-based micro-/nano-positioning system is proposed. The method is composed of an integer-pixel and a sub-pixel matching procedure. In the proposed algorithm (Pro-A), an improved ring projection transform (IRPT) and gradient information are used as features for approximating the coarse candidates and fine locations, respectively. Simulations are conducted and the results show that the Pro-A has the ability of rotation-invariance and strong robustness, with a theoretical accuracy of 0.01 pixel. To validate the practical performance, a series of experiments are carried out using a computer micro-vision and laser interferometer system (LIMS). The results demonstrate that both the LIMS and Pro-A can achieve high precision, while the Pro-A has better stability and adaptability.

  3. Relationship of condylar position to disc position and morphology

    Energy Technology Data Exchange (ETDEWEB)

    Incesu, L.; Taskaya-Yilmaz, N. E-mail: nergizy@omu.edu.tr; Oeguetcen-Toller, M.; Uzun, E

    2004-09-01

    Introduction/objective: The purpose of this study was to assess whether condylar position, as depicted by magnetic resonance imaging, was an indicator of disc morphology and position. Methods and material: One hundred and twenty two TMJs of 61 patients with temporomandibular joint disorder were examined. Condylar position, disc deformity and degree of anterior disc displacement were evaluated by using magnetic resonance imaging. Results and discussion: Posterior condyle position was found to be the main feature of temporomandibular joints with slight and moderate anterior disc displacement. No statistical significance was found between the condylar position, and reducing and nonreducing disc positions. On the other hand, superior disc position was found to be statistically significant for centric condylar position. Conclusion: It was concluded that posterior condyle position could indicate anterior disc displacement whereas there was no relation between the position of condyle and the disc deformity.

  4. Displacer Diameter Effect in Displacer Pulse Tube Refrigerator

    Science.gov (United States)

    Zhu, Shaowei

    2017-12-01

    Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.

  5. HTR-10GT AMBs displacement sensor design

    International Nuclear Information System (INIS)

    Shi Zhengang; Zha Meisheng; Zhao Lei; Sun Zhuo

    2005-01-01

    The 10 MW high temperature gas-cooled test module reactor (HTR-10GT) with the core made of spherical fuel elements was designed and constructed by the Institute of Nuclear and New Energy Technology of Tsinghua University in China. In the HTR-10GT, turbo-compressor and generator rotors are connected by a flexible coupling. The rotors, restricted by actual instruments and working environment, must be supported without any contact and lubrication. Active magnetic bearing (AMB), known as its advantages over the conventional bearings., such as contact-free, no-lubricating and active damping vibration, is the best way to suspend and stabilize the position of rotors of HTR-10GT. Each rotor is suspended by two radial and one axial AMBs. The radial AMB's radial gap is 0.15 mm considering the gap of 0.4 mm between the compressor stator and blades in order to protect the compressor. The control system controls the rotor position to meet the required gaps between rotor and stator through windings current. All the position information concerning radial and axial AMB is generated by sensors for measuring the displacement of the levitated body. Some typical sensors, i.e. eddy current displacement sensor, capacitive displacement sensor, can provide position information, but, quite often, unsatisfactory anti-jamming, which is a key issue for AMB systems near generator and other electric devices in HTR-10GT. Therefore, a kind of new type sensor is designed to measure the radial and axial displacements and the vibration of the rotors. This paper focuses on the design characteristics of the HTR-10GT AMBs displacement sensors and introduction of the related experiments to demonstrate its performance. (authors)

  6. Metrical analysis of disc-condyle relation with different splint treatment positions in patients with TMJ disc displacement

    Directory of Open Access Journals (Sweden)

    Mu-Qing Liu

    Full Text Available Abstract Objective: To evaluate the effect of bite positions characterizing different splint treatments (anterior repositioning and stabilization splints on the disc-condyle relation in patients with TMJ disc displacement with reduction (DDwR, using magnetic resonance imaging (MRI. Material and Methods: 37 patients, with a mean age of 18.8±4.3 years (7 male and 30 females and diagnosed with DDwR based on the RDC/TMD, were recruited. MRI metrical analysis of the spatial changes of the disc/condyle, as well as their relationships, was done in three positions: maximum intercuspation (Position 1, anterior repositioning splint position (Position 2, and stabilization splint position (Position 3. Disc/condyle coordinate measurements and disc condyle angles were determined and compared. Results: In Position 1, the average disc-condyle angle was 53.4° in the 60 joints with DDwR, while it was −13.3° with Position 2 and 30.1° with Position 3. The frequency of successful "disc recapture" with Position 2 was significantly higher (58/60, 96.7% than Position 3 (20/60, 33.3%. In Positions 2 and 3, the condyle moved forward and downward while the disc moved backward. The movements were, however, more remarkable with Position 2. Conclusions: Anterior repositioning of the mandible improves the spatial relationship between the disc and condyle in patients with DDwR. In addition to anterior and inferior movement of the condyle, transitory posterior movement of the disc also occurred.

  7. Project-induced displacement, secondary stressors, and health.

    Science.gov (United States)

    Cao, Yue; Hwang, Sean-Shong; Xi, Juan

    2012-04-01

    It has been estimated that about 15 million people are displaced by development projects around the world each year. Despite the magnitude of people affected, research on the health and other impacts of project-induced displacement is rare. This study extends existing knowledge by exploring the short-term health impact of a large scale population displacement resulting from China's Three Gorges Dam Project. The study is theoretically guided by the stress process model, but we supplement it with Cernea's impoverishment risks and reconstruction (IRR) model widely used in displacement literature. Our panel analysis indicates that the displacement is associated positively with relocatees' depression level, and negatively with their self-rated health measured against a control group. In addition, a path analysis suggests that displacement also affects depression and self-rated health indirectly by changing social integration, socioeconomic status, and community resources. The importance of social integration as a protective mechanism, a factor that has been overlooked in past studies of population displacement, is highlighted in this study. Published by Elsevier Ltd.

  8. Control rod displacement

    International Nuclear Information System (INIS)

    Nakazato, S.

    1987-01-01

    This patent describes a nuclear reactor including a core, cylindrical control rods, a single support means supporting the control rods from their upper ends in spaced apart positions and movable for displacing the control rods in their longitudinal direction between a first end position in which the control rods are fully inserted into the core and a second end position in which the control rods are retracted from the core, and guide means contacting discrete regions of the outer surface of each control rod at least when the control rods are in the vicinity of the second end position. The control rods are supported by the support means for longitudinal movement without rotation into and out of the core relative to the guide means to thereby cause the outer surface of the control rods to experience wear as a result of sliding contact with the guide means. The support means are so arranged with respect to the core and the guide means that it is incapable of rotation relative to the guide means. The improvement comprises displacement means being operatively coupled to a respective one of the control rods for periodically rotating the control rod in a single angular direction through an angle selected to change the locations on the outer surfaces of the control rods at which the control rods are contacted by the guide means during subsequent longitudinal movement of the control rods

  9. Water displacement mercury pump

    Science.gov (United States)

    Nielsen, M.G.

    1984-04-20

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  10. Metrological 2iOF fibre-optic system for position and displacement measurement with 31 pm resolution

    Science.gov (United States)

    Orłowska, Karolina; Świåtkowski, Michał; Kunicki, Piotr; Gotszalk, Teodor

    2018-04-01

    In the present paper, we describe a high sensitivity intensity fibre-optic displacement sensor with tens of picometre resolution combined with a sub-picometre resolution interferometric calibration system. Both integrated components form the so-called "2 in one ferrule" system 2iOF. The design and construction of the presented device depend on integrating two sensors' systems within one fibre-optic measuring head, which allows performing in situ calibration process with no additional time-consuming adjustment procedure. The resolution of the 2iOF system is 31 pm/Hz1/2 obtained with an interferometric Fabry-Perot based calibration system—providing accuracy better than tens of fm/Hz1/2 within 1 MHz bandwidth in the measurement range of up to 100 μm. The direct response from the intensity sensor is then the 2iOF output one. It is faster and more convenient to analyze in comparison, with much better resolution (3 orders of magnitude higher) but on the other hand also more time consuming and dependent on the absolute sample position interferometer. The proposed system is flexible and open to various applications. We will present the results of the piezoelectrical actuator displacement measurements, which were performed using the developed system.

  11. Etiopathogenesis of abomasal displacement in cattle

    Directory of Open Access Journals (Sweden)

    Šamanc Horea

    2003-01-01

    Full Text Available Abomasal displacement presents topographic gastropathy, where this organ has changed its position, and there is simultaneous dilatation which can vary in intensity. The incidence of this disorder in herds of high-yield dairy cows varies to a great degree (1 to 18 %. Abomasal displacement was established in herds of East-Frisian cows in 1 to 3% animals, and in Holstein cow herds in 5 to 18 % animals. The most frequent abomasal displacement is to the left (88%. There is significant seasonal variation in the incidence of abomasal displacement. About two-thirds of cases of abomasal displacement are diagnosed from October until April. The disorder appears more frequently in cows with repeated lactations. It has been established that it appears after the first calving in 27.8% cases, after the second to fifth calving in 66.7% cases, and after the sixth and seventh calving in 5.5% of the cows. The response of endocrine pancreas B-cells for insulin secretion to hyperglycaemia caused by applying an excess-glucose test is reduced in cows with left abomasal displacement, and there is constant hyperglycaemia in cows with right abomasal displacement. The excess-glucose test indicates a disrupted function of the endocrine pancreas in diseased animals. It has been determined through examinations of Aml genotypes in Holstein cow herds in connection with the appearance of abomasal displacement, that the occurrence of this disorder cannot be attributed to a genetic predisposition.

  12. Internal displacement in Colombia: Fifteen distinguishing features.

    Science.gov (United States)

    Shultz, James M; Ceballos, Ángela Milena Gómez; Espinel, Zelde; Oliveros, Sofia Rios; Fonseca, Maria Fernanda; Florez, Luis Jorge Hernandez

    2014-01-01

    This commentary aims to delineate the distinguishing features of conflict-induced internal displacement in the nation of Colombia, South America. Even as Colombia is currently implementing a spectrum of legal, social, economic, and health programs for "victims of armed conflict," with particular focus on internally displaced persons (IDPs), the dynamics of forced migration on a mass scale within this country are little known beyond national borders.   The authors of this commentary are embarking on a global mental health research program in Bogota, Colombia to define best practices for reaching the displaced population and implementing sustainable, evidence-based screening and intervention for common mental disorders. Presenting the defining characteristics of internal displacement in Colombia provides the context for our work and, more importantly, conveys the compelling and complex nature of this humanitarian crisis. We attempt to demonstrate Colombia's unique position within the global patterning of internal displacement.

  13. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  14. Sideways displacement and curved path of recti eye muscles

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); F. Harting (Friedrich); B.J. de Waal (Bob); B.W.J.M. Verbeeten (Ben)

    1985-01-01

    textabstractWe investigated the sideways displacement of recti muscles with the eye in various gaze-positions by making computed tomographic (CT) scans in a plane perpendicular to the muscle cone, posterior to the globe. We found no consistent sideways displacement of the horizontal recti in the up

  15. Design and Performance Analysis of Laser Displacement Sensor Based on Position Sensitive Detector (PSD)

    International Nuclear Information System (INIS)

    Song, H X; Wang, X D; Ma, L Q; Cai, M Z; Cao, T Z

    2006-01-01

    By using PSD as sensitive element, and laser diode as emitting element, laser displacement sensor based on triangulation method has been widely used. From the point of view of design, sensor and its performance were studied. Two different sensor configurations were described. Determination of the dimension, sensing resolution and comparison of the two different configurations were presented. The factors affecting the performance of the laser displacement sensor were discussed and two methods, which can eliminate the affection of dark current and environment light, are proposed

  16. Conservation-induced displacement: A comparative study of two Indian protected areas

    Directory of Open Access Journals (Sweden)

    Kabra Asmita

    2009-01-01

    Full Text Available Attempts at ′preservation via displacement′ are an extreme manifestation of the ′fortress′ or an exclusionary conservation paradigm, support for which has increased lately due to escalating conservation threats. While the policies and processes emanating from this paradigm have produced positive conservation outcomes for some Protected Areas, livelihood outcomes for the displaced people have seldom been as positive. This article examines whether the impoverishment risks arising from conservation-induced displacement tend to vary with the degree of marginalisation of the displaced community. In this light, this article examines in detail the impact on livelihood of conservation-induced displacement in two Protected Areas (PAs of India. The article posits that understanding the dynamic livelihood context of displaced communities, especially the ecological base of their livelihoods, is critical to any assessment of their pre- and post-displacement livelihood strategies and livelihood outcomes (such as income, poverty, food security and health. A variety of livelihood parameters, including compensation received, consumption flows, agricultural production, monetary income, food security, headcount ratio of poverty and overall poverty indices have been studied, to understand the extent to which key livelihood risks arising out of displacement are addressed by the rehabilitation package and process in the two PAs. The Sahariya is a forest-dependent Adivasi community living in and around the Kuno Wildlife Sanctuary in the semi-arid tropical region of Madhya Pradesh. The Sahariya Adivasis of the Kuno Sanctuary were a socially, politically and economically marginalised community, whose lives and livelihoods were intricately linked to their ecological base. We found that inadequate attention was paid to this factor while designing and implementing a suitable rehabilitation package for the 1650 Sahariya households displaced from this PA. As a result

  17. Displaced Sense: Displacement, Religion and Sense-making

    OpenAIRE

    Naidu, Maheshvari

    2016-01-01

    Whether formally categorized as refugees or not, displaced migrants experience varying degrees of vulnerability in relation to where they find themselves displaced. The internally displaced furthermore squat invisibly and outside the boundaries of the legal framework and incentive structures accorded to those classified as 'refugee'. They are thus arguably, by and large, left to source sustaining solutions for themselves. This article works through the theoretical prism of sense-making theory...

  18. Cross-cultural translation of the Lysholm knee score in Chinese and its validation in patients with anterior cruciate ligament injury.

    Science.gov (United States)

    Wang, W; Liu, L; Chang, X; Jia, Z Y; Zhao, J Z; Xu, W D

    2016-10-19

    The Lysholm Knee Score (LKS) is widely used and is one of the most effective questionnaires employed to assess knee injuries. Although LKS has been translated into multiple languages, there is no Chinese version even though China has the largest population of patients with knee-joint injuries. The objective of our study was to develop the Chinese version of LKS (C-LKS) and assess its reliability, validity and responsiveness in Chinese patients with anterior cruciate ligament (ACL) injuries. Study participants were mainly recruited among patients with ACL injuries scheduled for arthroscopic ACL reconstruction at our hospital. First, we developed the C-LKS in a five-step translation and cross-cultural adaptation procedure. Next, we calculated the Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) to evaluate the reliability, validity, and responsiveness of C-LKS respectively. Overall, 126 patients with ACL injuries successfully completed the questionnaires. Acceptable internal consistency (Cronbach's alpha = 0.726) as well as excellent test-retest reliability (ICC = 0.935) was found for C-LKS. Good or moderate correlation (r = 0.514-0.837) was determined among C-LKS and International Knee Documentation Committee Subjective Knee Form (IKDC), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), physical subscales of SF-36; C-LKS also had fair or moderate correlation (r = 0.207-0.462) with the other subscales of SF-36, which adequately illustrated that good validity was included in C-LKS. In addition, good responsiveness was also observed in C-LKS (ES = 1.36,SRM = 1.26). We have shown that our developed C-LKS questionnaire is reliable, valid and responsible for the evaluation of Chinese-speaking patients with ACL injuries and it would be an effective instrument.

  19. Correlation between direction and severity of temporomandibular joint disc displacement and reduction ability during mouth opening.

    Science.gov (United States)

    Litko, M; Berger, M; Szkutnik, J; Różyło-Kalinowska, I

    2017-12-01

    The most common temporomandibular joint (TMJ) internal derangement is an abnormal relationship of the disc with respect to the mandibular condyle, articular eminence and glenoid fossa-disc displacement. The aim of our study was to analyse the correlation between partial/complete disc displacement in the intercuspal position (IP) and its reduction in the open-mouth position (OMP) in both oblique sagittal and coronal planes on magnetic resonance imaging (MRI) in patients with temporomandibular disorders. Multisection MRI analysis of 382 TMJs was conducted in 191 patients with disc displacement according to the RDC/TMD criteria (148 women, 43 men; aged 14-60 years). The disc position was evaluated on all oblique sagittal and coronal images in the IP and the OMP. Univariate logistic regression analysis showed that the severity of disc displacement in the sagittal plane is a statistically significant predictor of reduction ability during mouth opening (B = 3.118; P displacement in both planes is also a significant predictor of disc reduction in OMP (B = 2.200; P displacement in IP, in both sagittal and coronal planes. Multisection analysis of all MR images allows distinguishing the correct disc position from disc displacement and can improve the ability to distinguish between various stages of TMJ internal derangement. © 2017 John Wiley & Sons Ltd.

  20. Chemical Shift Imaging (CSI) by precise object displacement

    OpenAIRE

    Leclerc, Sebastien; Trausch, Gregory; Cordier, Benoit; Grandclaude, Denis; Retournard, Alain; Fraissard, Jacques; Canet, Daniel

    2006-01-01

    International audience; A mechanical device (NMR lift) has been built for displacing vertically an object (typically a NMR sample tube) inside the NMR probe with an accuracy of 1 Μm. A series of single pulse experiments are performed for incremented vertical positions of the sample. With a sufficiently spatially selective rf field, one obtains chemical shift information along the displacement direction (one dimensional Chemical Shift Imaging – CSI). Knowing the vertical radio-frequency (rf) f...

  1. Displacement Parameter Inversion for a Novel Electromagnetic Underground Displacement Sensor

    Directory of Open Access Journals (Sweden)

    Nanying Shentu

    2014-05-01

    Full Text Available Underground displacement monitoring is an effective method to explore deep into rock and soil masses for execution of subsurface displacement measurements. It is not only an important means of geological hazards prediction and forecasting, but also a forefront, hot and sophisticated subject in current geological disaster monitoring. In previous research, the authors had designed a novel electromagnetic underground horizontal displacement sensor (called the H-type sensor by combining basic electromagnetic induction principles with modern sensing techniques and established a mutual voltage measurement theoretical model called the Equation-based Equivalent Loop Approach (EELA. Based on that work, this paper presents an underground displacement inversion approach named “EELA forward modeling-approximate inversion method”. Combining the EELA forward simulation approach with the approximate optimization inversion theory, it can deduce the underground horizontal displacement through parameter inversion of the H-type sensor. Comprehensive and comparative studies have been conducted between the experimentally measured and theoretically inversed values of horizontal displacement under counterpart conditions. The results show when the measured horizontal displacements are in the 0–100 mm range, the horizontal displacement inversion discrepancy is generally tested to be less than 3 mm under varied tilt angles and initial axial distances conditions, which indicates that our proposed parameter inversion method can predict underground horizontal displacement measurements effectively and robustly for the H-type sensor and the technique is applicable for practical geo-engineering applications.

  2. Understanding interferometry for micro-cantilever displacement detection

    Directory of Open Access Journals (Sweden)

    Alexander von Schmidsfeld

    2016-06-01

    Full Text Available Interferometric displacement detection in a cantilever-based non-contact atomic force microscope (NC-AFM operated in ultra-high vacuum is demonstrated for the Michelson and Fabry–Pérot modes of operation. Each mode is addressed by appropriately adjusting the distance between the fiber end delivering and collecting light and a highly reflective micro-cantilever, both together forming the interferometric cavity. For a precise measurement of the cantilever displacement, the relative positioning of fiber and cantilever is of critical importance. We describe a systematic approach for accurate alignment as well as the implications of deficient fiber–cantilever configurations. In the Fabry–Pérot regime, the displacement noise spectral density strongly decreases with decreasing distance between the fiber-end and the cantilever, yielding a noise floor of 24 fm/Hz0.5 under optimum conditions.

  3. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    International Nuclear Information System (INIS)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah; Azemin, Mohd Zulfaezal Che

    2015-01-01

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner

  4. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    Energy Technology Data Exchange (ETDEWEB)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah [Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia); Azemin, Mohd Zulfaezal Che [Department of Optometry and Visual Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia)

    2015-04-24

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

  5. Relationship between patellar mobility and patellofemoral joint cartilage degeneration after anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Ota, Susumu; Kurokouchi, Kazutoshi; Takahashi, Shigeo; Yoda, Masaki; Yamamoto, Ryuichiro; Sakai, Tadahiro

    2017-11-01

    Patellofemoral cartilage degeneration is a potential complication of anterior cruciate ligament reconstruction (ACLR) surgery. Hypomobility of the patella in the coronal plane is often observed after ACLR. Few studies, however, have examined the relationship between cartilage degeneration in the patellofemoral joint and mobility after ACLR. The present study investigated 1) the coronal mobility of the patella after ACLR, 2) the relationship between patellar mobility and cartilage degeneration of the patellofemoral joint, and 3) the relationship between patellar mobility and knee joint function after ACLR. Forty patients who underwent medial hamstring-based ACLR participated in the study. Lateral and medial patellar displacements were assessed with a modified patellofemoral arthrometer, and the absolute values of the displacements were normalized to patient height. The International Cartilage Repair Society (ICRS) cartilage injury classification of the patellar and femoral (trochlear) surfaces, and the Lysholm Knee Scoring Scale were used to evaluate knee function. Lateral and medial patellar displacements were reduced compared with the non-operated knee at the second-look arthroscopy and bone staple extraction operation (second operation; 24.4 ± 7.9 months after ACLR, Ppatellofemoral joint (patella and trochlea) were significantly worse than those pre-ACLR. Neither lateral nor medial patellar mobility, however, were significantly correlated with the ICRS grade or the Lysholm score. Although patellar mobility at approximately 2 years after ACLR was decreased compared to the non-operated knee, small displacement of the patella was not related to cartilage degeneration or knee joint function at the time of the second operation.

  6. Displacement ventilation

    DEFF Research Database (Denmark)

    Kosonen, Risto; Melikov, Arsen Krikor; Mundt, Elisabeth

    The aim of this Guidebook is to give the state-of-the art knowledge of the displacement ventilation technology, and to simplify and improve the practical design procedure. The Guidebook discusses methods of total volume ventilation by mixing ventilation and displacement ventilation and it gives...... insights of the performance of the displacement ventilation. It also shows practical case studies in some typical applications and the latest research findings to create good local micro-climatic conditions....

  7. Dealing with the Effects of Sensor Displacement in Wearable Activity Recognition

    Directory of Open Access Journals (Sweden)

    Oresti Banos

    2014-06-01

    Full Text Available Most wearable activity recognition systems assume a predefined sensor deployment that remains unchanged during runtime. However, this assumption does not reflect real-life conditions. During the normal use of such systems, users may place the sensors in a position different from the predefined sensor placement. Also, sensors may move from their original location to a different one, due to a loose attachment. Activity recognition systems trained on activity patterns characteristic of a given sensor deployment may likely fail due to sensor displacements. In this work, we innovatively explore the effects of sensor displacement induced by both the intentional misplacement of sensors and self-placement by the user. The effects of sensor displacement are analyzed for standard activity recognition techniques, as well as for an alternate robust sensor fusion method proposed in a previous work. While classical recognition models show little tolerance to sensor displacement, the proposed method is proven to have notable capabilities to assimilate the changes introduced in the sensor position due to self-placement and provides considerable improvements for large misplacements.

  8. An advanced CFD model to study the effect of non-condensable gas on cavitation in positive displacement pumps

    Directory of Open Access Journals (Sweden)

    Iannetti Aldo

    2015-09-01

    Full Text Available An advanced transient CFD model of a positive displacement reciprocating pump was created to study its behavior and performance in cavitating condition during the inlet stroke. The “full” cavitation model developed by Singhal et al. was utilized, and a sensitivity analysis test on two air mass fraction amounts (1.5 and 15 parts per million was carried out to study the influence of the dissolved air content in water on the cavitation phenomenon. The model was equipped with user defined functions to introduce the liquid compressibility, which stabilizes the simulation, and to handle the two-way coupling between the pressure field and the inlet valve lift history. Estimation of the performance is also presented in both cases.

  9. Reconstructing particle masses in events with displaced vertices

    Science.gov (United States)

    Cottin, Giovanna

    2018-03-01

    We propose a simple way to extract particle masses given a displaced vertex signature in event topologies where two long-lived mother particles decay to visible particles and an invisible daughter. The mother could be either charged or neutral and the neutral daughter could correspond to a dark matter particle in different models. The method allows to extract the parent and daughter masses by using on-shell conditions and energy-momentum conservation, in addition to the displaced decay positions of the parents, which allows to solve the kinematic equations fully on an event-by-event basis. We show the validity of the method by means of simulations including detector effects. If displaced events are seen in discovery searches at the Large Hadron Collider (LHC), this technique can be applied.

  10. Job Displacement and Crime

    DEFF Research Database (Denmark)

    Bennett, Patrick; Ouazad, Amine

    We use a detailed employer-employee data set matched with detailed crime information (timing of crime, fines, convictions, crime type) to estimate the impact of job loss on an individual's probability to commit crime. We focus on job losses due to displacement, i.e. job losses in firms losing...... a substantial share of their workers, for workers with at least three years of tenure. Displaced workers are more likely to commit offenses leading to conviction (probation, prison terms) for property crimes and for alcohol-related traffic violations in the two years following displacement. We find no evidence...... that displaced workers' propensity to commit crime is higher than non-displaced workers before the displacement event; but it is significantly higher afterwards. Displacement impacts crime over and above what is explained by earnings losses and weeks of unemployment following displacement....

  11. Multiplexed displacement fiber sensor using thin core fiber exciter.

    Science.gov (United States)

    Chen, Zhen; Hefferman, Gerald; Wei, Tao

    2015-06-01

    This letter reports a multiplexed optical displacement sensor using a thin core fiber (TCF) exciter. The TCF exciter is followed by a stripped single mode optical fiber. A small section of buffer is used as the movable component along the single mode fiber. Ultra-weak cladding mode reflection (< - 75 dB) was employed to probe the refractive index discontinuity between the air and buffer coating boundary. The position change of the movable buffer segment results in a delay change of the cladding mode reflection. Thus, it is a measure of the displacement of the buffer segment with respect to the glass fiber. The insertion loss of one sensor was measured to be less than 3 dB. A linear relationship was evaluated between the measurement position and absolute position of the moving actuator. Multiplexed capability was demonstrated and no cross talk was found between the sensors.

  12. Forced displacement and women's security in Colombia.

    Science.gov (United States)

    Meertens, Donny

    2010-04-01

    In the protracted Colombian conflict, assistance to internally displaced persons has developed in the context of contradictory political processes. The Colombian government's launching of a transitional justice process in the midst of armed conflict has generated a complex situation displaying both conflict and post-conflict characteristics. The progressive Constitutional Court rulings on internal displacement, in particular the gender-sensitive Auto 092, constitute an attempt to bring together humanitarian interventions and transitional justice measures in a rights-based framework. However, the national government is reluctant to adopt them fully and local realities still hamper their integrated implementation. Displaced women, therefore, remain in an especially vulnerable position. This paper argues that gender-sensitive humanitarian interventions must take into account all of these complexities of scale and political process in order to make legal frameworks more effective at the local level. In these contexts, interventions should pay particular attention to strategies that contribute to transforming pre-existing gender regimes.

  13. Simple force balance accelerometer/seismometer based on a tuning fork displacement sensor

    International Nuclear Information System (INIS)

    Stuart-Watson, D.; Tapson, J.

    2004-01-01

    Seismometers and microelectromechanical system accelerometers use the force-balance principle to obtain measurements. In these instruments the displacement of a mass object by an unknown force is sensed using a very high-resolution displacement sensor. The position of the object is then stabilized by applying an equal and opposite force to it. The magnitude of the stabilizing force is easily measured, and is assumed to be equivalent to the unknown force. These systems are critically dependent on the displacement sensor. In this article we use a resonant quartz tuning fork as the sensor. The tuning fork is operated so that its oscillation is lightly damped by the proximity of the movable mass object. Changes in the position of the mass object cause changes in the phase of the fork's resonance; this is used as the feedback variable in controlling the mass position. We have developed an acceleration sensor using this principle. The mass object is a piezoelectric bimorph diaphragm which is anchored around its perimeter, allowing direct electronic control of the displacement of its center. The tuning fork is brought very close to the diaphragm center, and is connected into a self-oscillating feedback circuit which has phase and amplitude as outputs. The diaphragm position is adjusted by a feedback loop, using phase as the feedback variable, to keep it in a constant position with respect to the tuning fork. The measured noise for this sensor is approximately 10.0 mg in a bandwidth of 100 Hz, which is substantially better than commercial systems of equivalent cost and size

  14. Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    Displacement ventilation is an interesting new type of air distribution principle which should be considered in connection with design of comfort ventilation in both smal1 and large spaces. Research activities on displacement ventilation are large all over the world and new knowledge of design...... methods appears continuously. This book gives an easy introduction to the basis of displacement ventilation and the chapters are written in the order which is used in a design procedure. The main text is extended by five appendices which show some of the new research activities taking place at Aalborg...

  15. Predicting positive mental health in internally displaced persons in Indonesia: the roles of economic improvement and exposure to violent conflict.

    Science.gov (United States)

    Saragih Turnip, Sherly; Sörbom, Dag; Hauff, Edvard

    2016-01-01

    Positive mental health, rather than just the absence of mental illness, is rarely investigated among the internally displaced persons (IDPs) affected by violent conflict in low-income countries. The purpose of this study was to investigate a model that could explain the interrelationship between factors contributing to positive mental health in displaced populations. In a longitudinal study we examine poverty, exposure to traumatic events and the change of material well-being after one year. We collected data in two consecutive years (2005 and 2006) from a community-based sample of IDPs in Ambon, Indonesia, through face-to-face structured interviews with consenting adults. Participants of this study were IDPs lived in Ambon during the violent conflict period. We interviewed 471 IDPs in the first year and reinterviewed 399 (85%) of the same subjects in the second year. The IDPs possessed good sense of coherence and subjective well-being. Our final model, which was generated by the use of structural equation modeling, fits the data well (χ(2) = 52.51, df = 45, p = .21, CFI = .99, RMSEA = .019). Exposure to violent conflict had a negative impact on IDPs' mental health initially and better economic conditions improved it (r = -.30 and .29 respectively). Mental health status one year previously was a strong predictor of future mental health, followed by individual economic growth in the past year (r = .43 and .29 respectively). On a group level the IDPs were resilient and adaptive to survive in adverse living conditions after devastating violent conflict, and the economic improvement contributed to it.

  16. The value of anterior displacement of the abdominal aorta in diagnosing neuroblastoma in children

    Energy Technology Data Exchange (ETDEWEB)

    Schiavon, Jose Luiz de Oliveira; Caran, Eliana Maria Monteiro; Lederman, Henrique Manoel, E-mail: schiavon00@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Odone Filho, Vicente [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina

    2016-11-15

    Objective: To determine the value of anterior displacement of the abdominal aorta, when present at any level or only at the level of the adrenal gland, contralateral to the mass, in diagnosing neuroblastoma on computed tomography or magnetic resonance imaging in children up to 7 years of age. Materials and Methods: Imaging examinations of 66 patients were classified by consensus as for the presence of anterior aorta displacement and were compared with the pathology report. Results: We found anterior abdominal aorta displacement in 26 (39.39%) of the 66 patients evaluated. Among those 26 patients, we identified neuroblastoma in 22 (84.62%), nephroblastoma in 3 (11.54%), and Burkitt lymphoma in 1 (3.85%). The positive predictive value was 84.62%, and the specificity was 88.24%. The displacement of the aorta was at the adrenal level, contralateral to the mass, in 14 cases, all of which were attributed to neuroblastoma. Conclusion: When the abdominal aorta is displaced at the level of the adrenal gland, contralateral to the mass, it can be said that the diagnosis is neuroblastoma, whereas abdominal aorta displacement occurring at other abdominal levels has a positive predictive value for neuroblastoma of approximately 85%. (author)

  17. The value of anterior displacement of the abdominal aorta in diagnosing neuroblastoma in children

    International Nuclear Information System (INIS)

    Schiavon, Jose Luiz de Oliveira; Caran, Eliana Maria Monteiro; Lederman, Henrique Manoel; Odone Filho, Vicente

    2016-01-01

    Objective: To determine the value of anterior displacement of the abdominal aorta, when present at any level or only at the level of the adrenal gland, contralateral to the mass, in diagnosing neuroblastoma on computed tomography or magnetic resonance imaging in children up to 7 years of age. Materials and Methods: Imaging examinations of 66 patients were classified by consensus as for the presence of anterior aorta displacement and were compared with the pathology report. Results: We found anterior abdominal aorta displacement in 26 (39.39%) of the 66 patients evaluated. Among those 26 patients, we identified neuroblastoma in 22 (84.62%), nephroblastoma in 3 (11.54%), and Burkitt lymphoma in 1 (3.85%). The positive predictive value was 84.62%, and the specificity was 88.24%. The displacement of the aorta was at the adrenal level, contralateral to the mass, in 14 cases, all of which were attributed to neuroblastoma. Conclusion: When the abdominal aorta is displaced at the level of the adrenal gland, contralateral to the mass, it can be said that the diagnosis is neuroblastoma, whereas abdominal aorta displacement occurring at other abdominal levels has a positive predictive value for neuroblastoma of approximately 85%. (author)

  18. Displacement of screw-retained single crowns into implants with conical internal connections.

    Science.gov (United States)

    Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Internal conical implant-abutment connections without platforms may lead to axial displacement of crowns during screw tightening. This displacement may affect proximal contacts, incisal edge position, or occlusion. This study aimed to measure the displacement of screw-retained single crowns into an implant in three dimensions during screw tightening by hand or via torque driver. A stereolithic acrylic resin cast was created using computed tomography data from a patient missing the maxillary right central incisor. A 4.0- × 11-mm implant was placed in the edentulous site. Five porcelain-fused-to-metal single crowns were made using "cast-to" abutments. Crowns were tried on the stereolithic model, representing the patient, and hand tightened. The spatial relationship of crowns to the model after hand tightening was determined using three-dimensional digital image correlation (3D DIC), an optical measurement technique. The crowns were then tightened using a torque driver to 20 Ncm and the relative crown positions were again recorded. Testing was repeated three times for each crown, and displacement of the crowns was compared between the hand-tightened and torqued states. Commercial image correlation software was used to analyze the data. Mean vertical and horizontal crown displacement values were calculated after torqueing. The interproximal contacts were evaluated before and after torquing using an 8-μm aluminum foil shim. There were vertical and horizontal differences in crown positions between hand tightening and torqueing. Although these were small in magnitude, detectable displacements occurred in both apical and facial directions. After hand tightening, the 8-μm shim could be dragged without tearing. However, after torque tightening, the interproximal contacts were too tight and the 8-μm shim could not be dragged without tearing. Differences between hand tightening and torque tightening should be taken into consideration during laboratory and clinical

  19. Insect Wing Displacement Measurement Using Digital Holography

    International Nuclear Information System (INIS)

    Aguayo, Daniel D.; Mendoza Santoyo, Fernando; Torre I, Manuel H. de la; Caloca Mendez, Cristian I.

    2008-01-01

    Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame rate digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement

  20. Natural history of minimal anterior displacements of the temporomandibular joint meniscus

    International Nuclear Information System (INIS)

    Drace, J.E.

    1988-01-01

    Magnetic resonance (MR) imaging of the temporomandibular joint (TMJ) often provides more precise localization of the meniscus than other imaging modalities. Previous study of the distribution of meniscus position in a control population showed that anterior displacements of more than 10 0 were more than 2 standard deviations from the mean, but the clinical significance and natural history of minimal displacements remained uncertain. Twenty follow-up MR studies were performed after 1-2 years in subjects with minimal meniscus displacements drawn from an original series of 125 symptomatic patients and 50 asymptomatic volunteers. These were correlated with repeated clinical histories and clinical examinations. A significant increase in the amount of anterior displacement was found in 55% of the originally asymptomatic volunteers with minimal displacements, which was accompanied by new symptoms in 40%. This was seen exclusively among those with a history of orthodontia. Worsening anterior displacements were seen in 50% of the patient population, and 25% had associated worsening symptoms. These findings indicate that detection of even minimal displacements of the TMJ meniscus is necessary and warrants follow-up MR examinations. Routine follow-up MR images should be obtained following malocclusion treatment and after major dental procedures

  1. Active Control Does Not Eliminate Motion-Induced Illusory Displacement

    Directory of Open Access Journals (Sweden)

    Ian M. Thornton

    2011-05-01

    Full Text Available When the sine-wave grating of a Gabor patch drifts to the left or right, the perceived position of the entire object is shifted in the direction of local motion. In the current work we explored whether active control of the physical position of the patch overcomes such motion induced illusory displacement. In Experiment 1 we created a simple computer game and asked participants to continuously guide a Gabor patch along a randomly curving path using a joystick. When the grating inside the Gabor patch was stationary, participants could perform this task without error. When the grating drifted to either left or right, we observed systematic errors consistent with previous reports of motion-induced illusory displacement. In Experiment 2 we created an iPad application where the built-in accelerometer tilt control was used to steer the patch through as series of “gates”. Again, we observed systematic guidance errors that depended on the direction and speed of local motion. In conclusion, we found no evidence that participants could adapt or compensate for illusory displacement given active control of the target.

  2. The study on the X-ray correction method of long fracture displacement

    International Nuclear Information System (INIS)

    Jia Bin; Huang Ailing; Chen Fuzhong; Men Chunyan; Sui Chengzong; Cui Yiming; Yang Yundong

    2010-01-01

    Objective: To explore the image correction of fracture displacement by conventional X-ray photography (ortho tropic and lateral) and test by computed tomography (CT). Methods: The correction method of fracture displacement was designed according to geometry of X-ray photography. Selected one midhumeral fracture specimen which designed with lateral shift and angular displacement, and scanned from anteroposterior and position respectively, and also volume scanned using CT, the data obtained from volume scan were processed using multiplanar reconstruction (MPR) and shaded surface display (SSD). The displacement data relied on X-ray image, CT with MPR and SSD processing, actual design of specimens were compared respectively. Results: The direction and degree of displacement among correction data of X-ray images and the data from MPR and SSD, actual design of specimen were little difference, location difference <1.5 mm, degree difference <1.5 degree. Conclusion: It is really reliable for fracture displacement by conventional X-ray photography with coordinate correction, and it is helpful to obviously improve the diagnostic accuracy of the degree of fracture displacement. (authors)

  3. A Static Displacement Monitoring System for VLBI Antenna Using Close-Range Photogrammetry

    Directory of Open Access Journals (Sweden)

    Hyukgil Kim

    2017-11-01

    Full Text Available In this study, a static displacement monitoring program was developed to maintain the accurate performance of a Very Long Baseline Interferometry (VLBI antenna by monitoring its structural stability. The monitoring program was designed to measure static displacement, among the many displacements of the antenna’s main reflector, which can directly affect its performance. The program measures the position of a monitored object with mm-level accuracy through close-range photogrammetry that uses high-resolution Charge Coupled Device (CCD cameras. The developed program will be used to evaluate the structural soundness of an antenna based on continuous displacement measurements, which can also be used as basic data for repair and reinforcement work in the future.

  4. Displacement characteristics of a piezoactuator-based prototype microactuator with a hydraulic displacement amplification system

    Energy Technology Data Exchange (ETDEWEB)

    Muralidhara [NMAMIT, Nitte (India); Rao, Rathnamala [NITK, Surathkal (India)

    2015-11-15

    In this study, a new piezoactuator-based prototype microactuator is proposed with a hydraulic displacement amplification system. A piezoactuator is used to deflect a diaphragm which displaces a certain volume of hydraulic fluid into a smaller-diameter piston chamber, thereby amplifying the displacement at the other end of the piston. An electro-mechanical model is implemented to estimate the displacement of a multilayer piezoelectric actuator for the applied input voltage considering the hysteresis behavior. The displacement characteristics of the proposed microactuator are studied for triangular actuation voltage signal. Results of the experiments and simulation of the displacement behavior of the stacked piezoactuator and the amplified displacement of the prototype actuator were compared. Experimental results suggest that the mathematical model developed for the new piezoactuator-based prototype actuator is capable of estimating its displacement behavior accurately, within an error of 1.2%.

  5. Displacement characteristics of a piezoactuator-based prototype microactuator with a hydraulic displacement amplification system

    International Nuclear Information System (INIS)

    Muralidhara; Rao, Rathnamala

    2015-01-01

    In this study, a new piezoactuator-based prototype microactuator is proposed with a hydraulic displacement amplification system. A piezoactuator is used to deflect a diaphragm which displaces a certain volume of hydraulic fluid into a smaller-diameter piston chamber, thereby amplifying the displacement at the other end of the piston. An electro-mechanical model is implemented to estimate the displacement of a multilayer piezoelectric actuator for the applied input voltage considering the hysteresis behavior. The displacement characteristics of the proposed microactuator are studied for triangular actuation voltage signal. Results of the experiments and simulation of the displacement behavior of the stacked piezoactuator and the amplified displacement of the prototype actuator were compared. Experimental results suggest that the mathematical model developed for the new piezoactuator-based prototype actuator is capable of estimating its displacement behavior accurately, within an error of 1.2%.

  6. Measuring vulnerability to disaster displacement

    Science.gov (United States)

    Brink, Susan A.; Khazai, Bijan; Power, Christopher; Wenzel, Friedemann

    2015-04-01

    Large scale disasters can cause devastating impacts in terms of population displacement. Between 2008 and 2013, on average 27 million people were displaced annually by disasters (Yonetani 2014). After large events such as hurricane Katrina or the Port-au-Prince earthquake, images of inadequate public shelter and concerns about large scale and often inequitable migration have been broadcast around the world. Population displacement can often be one of the most devastating and visible impacts of a natural disaster. Despite the importance of population displacement in disaster events, measures to understand the socio-economic vulnerability of a community often use broad metrics to estimate the total socio-economic risk of an event rather than focusing on the specific impacts that a community faces in a disaster. Population displacement is complex and multi-causal with the physical impact of a disaster interacting with vulnerability arising from the response, environmental issues (e.g., weather), cultural concerns (e.g., expectations of adequate shelter), and many individual factors (e.g., mobility, risk perception). In addition to the complexity of the causes, population displacement is difficult to measure because of the wide variety of different terms and definitions and its multi-dimensional nature. When we speak of severe population displacement, we may refer to a large number of displaced people, an extended length of displacement or associated difficulties such as poor shelter quality, risk of violence and crime in shelter communities, discrimination in aid, a lack of access to employment or other difficulties that can be associated with large scale population displacement. We have completed a thorough review of the literature on disaster population displacement. Research has been conducted on historic events to understand the types of negative impacts associated with population displacement and also the vulnerability of different groups to these impacts. We

  7. How much vertical displacement of the symphysis indicates instability after pelvic injury?

    Science.gov (United States)

    Golden, Robert D; Kim, Hyunchul; Watson, Jeffrey D; Oliphant, Bryant W; Doro, Christopher; Hsieh, Adam H; Osgood, Greg M; O'Toole, Robert V

    2013-02-01

    Measures of pubic symphyseal widening are used by at least two classification systems as determinants of injury grade. Recent work has challenged the commonly used parameter of 2.5 cm of pubic symphysis as an accurate marker of pelvic injury grade and has suggested a role of rotation in the flexion-extension plane as a determinant of pelvic stability. We investigated pelvic stability in the flexion-extension plane to determine a threshold of rotational displacement of the hemipelvis above which the potential for instability exists. Cadaveric specimens were mounted onto a servohydraulic biaxial testing machine and subjected to a vertically directed flexion moment. Position of hemipelvis was recorded using a three-dimensional motion capture system and video recording. Displacement of the pubic symphysis and changes in length and position of the sacrospinous and sacrotuberous ligaments were recorded. Amount of force applied was measured and recorded. A yield point was determined as the first point at which the force plot exhibited a decrease in force and was correlated to the corresponding displacement. The mean vertical displacement of the pubic symphysis at the yield point was 16 mm (95% confidence interval, 11-22 mm). Mean sacrospinous ligament strain at yield point was 4% (range, 1.0-9.5%). Pelves with vertical rotational symphyseal displacement of less than 11 mm can reasonably be expected to have rotational stability in the flexion-extension plane. Those with displacement of greater than 22 mm can be expected to have lost some integrity regarding resistance to pelvic flexion. These values may allow clinicians to infer pelvic stability from amount of vertical symphyseal displacement.

  8. Soft Pneumatic Bending Actuator with Integrated Carbon Nanotube Displacement Sensor

    Directory of Open Access Journals (Sweden)

    Tim Giffney

    2016-02-01

    Full Text Available The excellent compliance and large range of motion of soft actuators controlled by fluid pressure has lead to strong interest in applying devices of this type for biomimetic and human-robot interaction applications. However, in contrast to soft actuators fabricated from stretchable silicone materials, conventional technologies for position sensing are typically rigid or bulky and are not ideal for integration into soft robotic devices. Therefore, in order to facilitate the use of soft pneumatic actuators in applications where position sensing or closed loop control is required, a soft pneumatic bending actuator with an integrated carbon nanotube position sensor has been developed. The integrated carbon nanotube position sensor presented in this work is flexible and well suited to measuring the large displacements frequently encountered in soft robotics. The sensor is produced by a simple soft lithography process during the fabrication of the soft pneumatic actuator, with a greater than 30% resistance change between the relaxed state and the maximum displacement position. It is anticipated that integrated resistive position sensors using a similar design will be useful in a wide range of soft robotic systems.

  9. Seismic displacements monitoring for 2015 Mw 7.8 Nepal earthquake with GNSS data

    Science.gov (United States)

    Geng, T.; Su, X.; Xie, X.

    2017-12-01

    The high-rate Global Positioning Satellite System (GNSS) has been recognized as one of the powerful tools for monitoring ground motions generated by seismic events. The high-rate GPS and BDS data collected during the 2015 Mw 7.8 Nepal earthquake have been analyzed using two methods, that are the variometric approach and Precise point positioning (PPP). The variometric approach is based on time differenced technique using only GNSS broadcast products to estimate velocity time series from tracking observations in real time, followed by an integration procedure on the velocities to derive the seismic event induced displacements. PPP is a positioning method to calculate precise positions at centimeter- or even millimeter-level accuracy with a single GNSS receiver using precise satellite orbit and clock products. The displacement motions with accuracy of 2 cm at far-field stations and 5 cm at near-field stations with great ground motions and static offsets up to 1-2 m could be achieved. The multi-GNSS, GPS + BDS, could provide higher accuracy displacements with the increasing of satellite numbers and the improvement of the Position Dilution of Precision (PDOP) values. Considering the time consumption of clock estimates and the precision of PPP solutions, 5 s GNSS satellite clock interval is suggested. In addition, the GNSS-derived displacements are in good agreement with those from strong motion data. These studies demonstrate the feasibility of real-time capturing seismic waves with multi-GNSS observations, which is of great promise for the purpose of earthquake early warning and rapid hazard assessment.

  10. Online Image-based Monitoring of Soft-tissue Displacements for Radiation Therapy of the Prostate

    International Nuclear Information System (INIS)

    Schlosser, Jeffrey; Salisbury, Kenneth; Hristov, Dimitre

    2012-01-01

    Purpose: Emerging prolonged, hypofractionated radiotherapy regimens rely on high-dose conformality to minimize toxicity and thus can benefit from image guidance systems that continuously monitor target position during beam delivery. To address this need we previously developed, as a potential add-on device for existing linear accelerators, a novel telerobotic ultrasound system capable of real-time, soft-tissue imaging. Expanding on this capability, the aim of this work was to develop and characterize an image-based technique for real-time detection of prostate displacements. Methods and Materials: Image processing techniques were implemented on spatially localized ultrasound images to generate two parameters representing prostate displacements in real time. In a phantom and five volunteers, soft-tissue targets were continuously imaged with a customized robotic manipulator while recording the two tissue displacement parameters (TDPs). Variations of the TDPs in the absence of tissue displacements were evaluated, as was the sensitivity of the TDPs to prostate translations and rotations. Robustness of the approach to probe force was also investigated. Results: With 95% confidence, the proposed method detected in vivo prostate displacements before they exceeded 2.3, 2.5, and 2.8 mm in anteroposterior, superoinferior, and mediolateral directions. Prostate pitch was detected before exceeding 4.7° at 95% confidence. Total system time lag averaged 173 ms, mostly limited by ultrasound acquisition rate. False positives (FPs) (FP) in the absence of displacements did not exceed 1.5 FP events per 10 min of continuous in vivo imaging time. Conclusions: The feasibility of using telerobotic ultrasound for real-time, soft-tissue–based monitoring of target displacements was confirmed in vivo. Such monitoring has the potential to detect small clinically relevant intrafractional variations of the prostate position during beam delivery.

  11. Nuclear reactor control device by vertical displacement of neutron absorber scram rods

    International Nuclear Information System (INIS)

    Defaucheux, Jacques; Pasqualini, Gilbert; Wiart, Albert; Martin, Jean.

    1981-01-01

    Nuclear reactor control system by vertical displacement of an assembly absorbing the neutrons inside a reactor core and drop of the absorbing assembly in maximum insertion position under the effect of its own weight for emergency shutdown. The absorbing assembly is secured to the bottom end of a vertical control rod, the displacement of which is actuated by an electro-magnetic device [fr

  12. Generating Sub-nanometer Displacement Using Reduction Mechanism Consisting of Torsional Leaf Spring Hinges

    Directory of Open Access Journals (Sweden)

    Fukuda Makoto

    2014-02-01

    Full Text Available Recent demand on the measurement resolution of precise positioning comes up to tens of picometers. Some distinguished researches have been performed to measure the displacement in picometer order, however, few of them can verify the measurement performance as available tools in industry. This is not only because the picometer displacement is not yet required for industrial use, but also due to the lack of standard tools to verify such precise displacement. We proposed a displacement reduction mechanism for generating precise displacement using torsional leaf spring hinges (TLSHs that consist of four leaf springs arranged radially. It has been demonstrated that a prototype of the reduction mechanism was able to provide one-nanometer displacement with 1/1000 reduction rate by a piezoelectric actuator. In order to clarify the potential of the reduction mechanism, a displacement reduction table that can be mounted on AFM stage was newly developed using TLSHs. This paper describes the design of the reduction mechanism and the sub-nanometer displacement performance of the table obtained from its dynamic and static characteristics measured by displacement sensors and from the AFM images

  13. Temperature and displacement transients in inertial confinement fusion first-walls

    International Nuclear Information System (INIS)

    Hunter, T.O.; Kulcinski, G.L.

    1977-01-01

    A quasi-analytic general model is developed for determination of temperature response and displacement damage in materials exposed to bursts of thermonuclear radiations. Temperature response can be determined for any time or position. Materials are assessed, using the model, which might be employed for dry first walls, collectors, laser mirrors, or other exposed reactor components. The resulting magnitude and temporal distribution of temperature and displacement production show that effects on material micro-structure must be treated in a dynamic fashion

  14. Resonant neutron-induced atomic displacements

    Energy Technology Data Exchange (ETDEWEB)

    Elmaghraby, Elsayed K., E-mail: e.m.k.elmaghraby@gmail.com

    2017-05-01

    Highlights: • Neutron induced atomic displacements was investigated based on scattering of energy of neutron. • Model for cascade function (multiplication of displacements with increasing energy transfer) was proposed and justified. • Parameterizations for the dpa induced in all elements were performed. • Table containing all necessary parameters to calculate the displacement density induced by neutron is given. • Contribution of non resonance displacement and resonant-neutron induced displacements are distinguished. - Abstract: A model for displacement cascade function was modified to account for the continuous variation of displacement density in the material in response to neutron exposure. The model is based on the Gaussian distribution of displacement energies of atoms in a material. Analytical treatment for moderated epithermal neutron field was given in which the displacement density was divided into two terms, discrete-resonance term and continuum term. Calculation are done for all isotopes using ENDF/B VII.1 data files and temperature dependent cross section library. Weighted elemental values were reported a fitting was performed to obtain energy-dependent formula of displacement density and reduce the number of parameters. Results relevant the present specification of the cascade function are tabulated for each element to enable calculation of displacement density at any value of displacement energy in the between 5 eV and 55 eV.

  15. Detecting the position of the moving-iron solenoid by non-displacement sensor based on parameter identification of flux linkage characteristics

    Science.gov (United States)

    Wang, Xuping; Quan, Long; Xiong, Guangyu

    2013-11-01

    Currently, most researches use signals, such as the coil current or voltage of solenoid, to identify parameters; typically, parameter identification method based on variation rate of coil current is applied for position estimation. The problem exists in these researches that the detected signals are prone to interference and difficult to obtain. This paper proposes a new method for detecting the core position by using flux characteristic quantity, which adds a new group of secondary winding to the coil of the ordinary switching electromagnet. On the basis of electromagnetic coupling theory analysis and simulation research of the magnetic field regarding the primary and secondary winding coils, and in accordance with the fact that under PWM control mode varying core position and operating current of windings produce different characteristic of flux increment of the secondary winding. The flux increment of the electromagnet winding can be obtained by conducting time domain integration for the induced voltage signal of the extracted secondary winding, and the core position from the two-dimensional fitting curve of the operating winding current and flux-linkage characteristic quantity of solenoid are calculated. The detecting and testing system of solenoid core position is developed based on the theoretical research. The testing results show that the flux characteristic quantity of switching electromagnet magnetic circuit is able to effectively show the core position and thus to accomplish the non-displacement transducer detection of the said core position of the switching electromagnet. This paper proposes a new method for detecting the core position by using flux characteristic quantity, which provides a new theory and method for switch solenoid to control the proportional valve.

  16. Job Displacement and Crime

    DEFF Research Database (Denmark)

    Bennett, Patrick; Ouazad, Amine

    theory of crime. Marital dissolution is more likely post-displacement, and we find small intra-family externalities of adult displacement on younger family members’ crime. The impact of displacement on crime is stronger in municipalities with higher capital and labor income inequalities....

  17. Ocular surface displacement with and without contact lenses during non-contact tonometry.

    Science.gov (United States)

    Rimayanti, Ulfah; Kiuchi, Yoshiaki; Uemura, Shohei; Takenaka, Joji; Mochizuki, Hideki; Kaneko, Makoto

    2014-01-01

    To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs). One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL), with -5.0 diopters (D), -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated. The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time. Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.

  18. Self-Aligning and Self-Calibrating Capacitive Sensor System for Displacement Measurement in Inaccessible Industrial Environments

    NARCIS (Netherlands)

    van de Ven, Oscar; Vogel, J.G.; Xia, Sha; Spronck, J.W.; Nihtianov, S.

    2017-01-01

    High-precision positioning often requires high speed and high resolution displacement measurements in order to compensate for the small vibrations of critical components. The displacement sensor must be precise and stable over a long period of time to avoid expensive recalibration. This requires

  19. Impact of balancing-side tooth contact on clenching induced mandibular displacements in humans.

    Science.gov (United States)

    Baba, K; Yugami, K; Yaka, T; Ai, M

    2001-08-01

    This study investigated mandibular displacements during clenching in the lateral mandibular position in relation to lateral occlusal relationships. Twelve healthy human subjects (mean=26.7 years) volunteered for this study. Acrylic occlusal devices were fabricated for the lower working-side canine, working-side second molar and balancing-side second molar in order to simulate a dominant canine guidance, working-side interference (WI), balancing-side interference (BI) and bilateral balanced occlusion (BO). Vertical displacements of the mandible were recorded by linear variable differential transformers during submaximal clenching in the right lateral position. The four experimental occlusal conditions were revealed to have a significant effect on mandibular displacement patterns (ANOVA, P experimental conditions. These results suggest that the nature of reaction forces at the temporomandibular (TM) joints caused by the elevation of the mandible varies in a predictable manner depending upon lateral occlusal relationships.

  20. Displacement of the normal pituitary gland by sellar and juxtasellar tumours: surgical-MRI correlation and use in differential diagnosis

    International Nuclear Information System (INIS)

    Sumida, M.; Uozumi, T.; Yamanaka, M.; Mukada, K.; Arita, K.; Kurisu, K.; Satoh, H.; Ikawa, F.

    1994-01-01

    We compared the position of the normal pituitary gland as estimated by gadolinium (Gd)-DTPA-enhanced MRI, with its position at surgery in 40 patients with intra- and juxtasellar tumours: 22 pituitary adenomas, 4 craniopharyngiomas, 7 meningiomas, 2 germinomas, and 5 Rathke cleft cysts. In 37 of these, the normal gland showed more intense contrast enhancement than the adjacent tumour, from which it could be differentiated by Gd-DTPA-enhanced MRI, especially in the sagittal plane. The direction of displacement of the normal pituitary gland correlated well with tumour type, so that its position proved helpful in the differential diagnosis. The normal gland was typically displaced superiorly by pituitary adenomas, inferiorly by craniopharyngiomas, and anteriorly by germinomas. It showed variable displacement by Rathke cleft cysts, and was not usually displaced by meningiomas. (orig.)

  1. Biomechanical model-based displacement estimation in micro-sensor motion capture

    International Nuclear Information System (INIS)

    Meng, X L; Sun, S Y; Wu, J K; Zhang, Z Q; 3 Building, 21 Heng Mui Keng Terrace (Singapore))" data-affiliation=" (Department of Electrical and Computer Engineering, National University of Singapore (NUS), 02-02-10 I3 Building, 21 Heng Mui Keng Terrace (Singapore))" >Wong, W C

    2012-01-01

    In micro-sensor motion capture systems, the estimation of the body displacement in the global coordinate system remains a challenge due to lack of external references. This paper proposes a self-contained displacement estimation method based on a human biomechanical model to track the position of walking subjects in the global coordinate system without any additional supporting infrastructures. The proposed approach makes use of the biomechanics of the lower body segments and the assumption that during walking there is always at least one foot in contact with the ground. The ground contact joint is detected based on walking gait characteristics and used as the external references of the human body. The relative positions of the other joints are obtained from hierarchical transformations based on the biomechanical model. Anatomical constraints are proposed to apply to some specific joints of the lower body to further improve the accuracy of the algorithm. Performance of the proposed algorithm is compared with an optical motion capture system. The method is also demonstrated in outdoor and indoor long distance walking scenarios. The experimental results demonstrate clearly that the biomechanical model improves the displacement accuracy within the proposed framework. (paper)

  2. Internal Displacement: Livelihood saving responses

    OpenAIRE

    Deborah Hines

    2001-01-01

    Deborah Hines explores how to assist the internally displaced and those prone to displacement. She considers the major causes of internal displacement, making the case for a more comprehensive set of policy and operational actions in response to situations of internal displacement. Development (2001) 44, 34–39. doi:10.1057/palgrave.development.1110289

  3. Ocular surface displacement with and without contact lenses during non-contact tonometry.

    Directory of Open Access Journals (Sweden)

    Ulfah Rimayanti

    Full Text Available PURPOSE: To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP reading changes caused by wearing soft contact lenses (CLs. METHODS: One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL, with -5.0 diopters (D, -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated. RESULTS: The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time. CONCLUSIONS: Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.

  4. [MINIMALLY INVASIVE TREATMENT OF POSTERIOR CRUCIATE LIGAMENT AVULSION FRACTURE IN A FLOPPY LATERAL POSITION].

    Science.gov (United States)

    Zhao, Junchao; Wang, Hao

    2016-09-08

    To conclude the effectiveness of arthroscopy combined with Burks and SchaVer's approach in the treatment of posterior cruciate ligament (PCL) avulsion fractures in a floppy lateral position. Between May 2010 and March 2014, 21 patients with PCL avulsion fractures were treated. There were 13 males and 8 females, aged 21 to 62 years (mean, 39.1 years). The causes included traffic accident injury in 10 cases, sports injury in 5 cases, and falling injury from height in 6 cases. The time from injury to hospital was 1-6 days (mean, 2.5 days). The results of posterior drawer test were all positive, and the results of anterior drawer test and lateral stress test were all negative. The Lysholm score was 28.0±5.5 before operation. And the American Orthopaedic Foot and Ankle Society (IKDC) score was 46.2±7.6 before operation. According to Meyer standards for fractures classification, 11 cases were rated as type II and 10 cases as type III. Arthroscopy was used to inspect and treat the intra-articular lesions, then avulsion fracture was fixed by Burks and SchaVer's approach in lateral position. Postoperative functional exercises were performed. Primary healing of incision was obtained, without nerve and vascular injury or joint infection. All patients were followed up 18-36 months (mean, 27.2 months). The X-ray films of the knee joint showed good fractures reduction and healing at 3 months after operation. The results of posterior drawer test and reverse Lachman test were negative. The knee range of motion was recovered to normal level. At last follow-up, the Lysholm score of the knee joint was significantly improved to 90.9±1.4 from preoperative one ( t =54.584, P =0.000), and the IKDC score was significantly increased to 90.5±5.3 from preoperative one ( t =15.638, P =0.000), including 19 cases of grade A and 2 cases of grade B. A combination of arthroscopy and Burks and SchaVer's approach for the treatment of PCL avulsion fractures in a floppy lateral position has the

  5. Large displacement spring-like electro-mechanical thermal actuators with insulator constraint beams

    Science.gov (United States)

    Luo, J. K.; Fu, Y. Q.; Flewitt, A. J.; Spearing, S. M.; Fleck, N. A.; Milne, W. I.

    2005-07-01

    A number of in-plane spring-like micro-electro-thermal-actuators with large displacements were proposed. The devices take the advantage of the large difference in the thermal expansion coefficients between the conductive arms and the insulator clamping beams. The constraint beams in one type (the spring) of these devices are horizontally positioned to restrict the expansion of the active arms in the x-direction, and to produce a displacement in the y-direction only. In other two types of actuators (the deflector and the contractor), the constraint beams are positioned parallel to the active arms. When the constraint beams are on the inside of the active arms, the actuator produces an outward deflection in the y-direction. When they are on the outside of the active arms, the actuator produces an inward contraction. Analytical model and finite element analysis were used to simulate the performances. It showed that at a constant temperature, analytical model is sufficient to predict the displacement of these devices. The displacements are all proportional to the temperature and the number of the chevron sections. A two-mask process is under development to fabricate these devices, using Si3N4 as the insulator beams, and electroplated Ni as the conductive beams.

  6. Thirty years of development-induced displacement in China

    Directory of Open Access Journals (Sweden)

    François Dubé

    2016-01-01

    Full Text Available To accelerate the process of poverty reduction in its poorer regions, China decided in 2001 to implement a national programme of displacement of populations living in areas considered environmentally fragile. But these programmes were hardly a novelty for China, and the record of previous such attempts has been far from positive.

  7. Nanoscale displacement sensing using microfabricated variable-inductance planar coils

    Science.gov (United States)

    Coskun, M. Bulut; Thotahewa, Kasun; Ying, York-Sing; Yuce, Mehmet; Neild, Adrian; Alan, Tuncay

    2013-09-01

    Microfabricated spiral inductors were employed for nanoscale displacement detection, suitable for use in implantable pressure sensor applications. We developed a variable inductor sensor consisting of two coaxially positioned planar coils connected in series to a measurement circuit. The devices were characterized by varying the air gap between the coils hence changing the inductance, while a Colpitts oscillator readout was used to obtain corresponding frequencies. Our approach shows significant advantages over existing methodologies combining a displacement resolution of 17 nm and low hysteresis (0.15%) in a 1 × 1 mm2 device. We show that resolution could be further improved by shrinking the device's lateral dimensions.

  8. Locating the displacement of the steel wire implantation with the stereotactic mammography

    International Nuclear Information System (INIS)

    Ma Jie; Xu Jianmin; Sun Guomin; Sun Guoping; Zang Da; Zhou Dongxian; Mai Peicheng

    2007-01-01

    Objective: To analyze the manifestation, reason, the processing method of the steel wire implantation with the stereotactic mammography to improve the accuracy of the preoperative positioning. Methods: Seventy-nine cases which got the stereotactic steel wire implantation. In 96 lesions, 13 had steel wire displacement. Among them, 5 cases got steel wire displacement during the stereotactic process, 5 cases got steel wire displacement after the stereotactic process, 2 cases got steel wire displacement during the operation, one case did not show the calcification on the postoperative radiography. Results: The steel wire displacement occurred in 5 cases during the stereotactic process came from the patients and doctors respectively and the repositioning was needed. The steel wire displacement after the stereoscopic positioning was attributed to the overdose injection of local anesthesia, which led to the mismatch between the depth of Z axis of the mammary gland and the actual depth the computer given, the incorrect method for needle placement, and, neglecting whether the steel wire have got the lesion anchored when pulling out the needle set of steel wire hood, besides, these three kinds of instances above were all exaggerated by the accordion effect. For the displacement within 2 cm, the lesion can be excised toward the pathological change direction according to the position that steel wire prompted and re-place the second steel wire, putting the J-shaped steel wire into the needle hood and taking it out of the body. After repositioning, 2 cases had the steel wire prolapse during operation, which resulted from the over-lifting of the steel wire. After placing the steel wire, the radiologist should give an accurate description on the depth and direction to the surgeon and the notch should be taken for incision from the steel wire head end which is proximate to skin. The postoperative specimen from one case had no calcification, which might be related to the condition

  9. The Distal Humerus Axial View: Assessment of Displacement in Medial Epicondyle Fractures.

    Science.gov (United States)

    Souder, Christopher D; Farnsworth, Christine L; McNeil, Natalie P; Bomar, James D; Edmonds, Eric W

    2015-01-01

    The assessment and treatment of childhood medial epicondyle humerus fractures continues to be associated with significant debate. Several studies demonstrate that standard radiographic views are unable to accurately portray the true displacement. Without reliable ways to assess the amount of displacement, how can we debate treatment and outcomes? This study introduces a novel imaging technique for the evaluation of medial epicondyle fractures. An osteotomy of a cadaveric humerus was performed to simulate a medial epicondyle fracture. Plain radiographs were obtained with the fracture fragment displaced anteriorly in 2-mm increments between 0 and 18 mm. Anteroposterior (AP), internal oblique (IR), lateral (LAT), and distal humerus axial (AXIAL) views were performed. Axial images were obtained by positioning the central ray above the shoulder at 15 to 20 degrees from the long axis of the humerus, centered on the distal humerus. Displacement (mm) was measured by 7 orthopaedic surgeons on digital radiographs. At 10 mm displacement, AP views underestimated displacement by 5.5±0.6 mm and IR views underestimated by 3.8±2.1 mm. On LAT views, readers were not able to visualize fragments with displacement. Displacement ≥10 mm from LAT views was overestimated by 1 reader by up to 4.6 mm and underestimated by others by up to 18.0 mm. AXIAL images more closely estimated the true amount of displacement, with a mean 1.5±1.1 mm error in measurement for displacement and a mean 0.8±0.7 mm error for displacements of ≥10 mm. AXIAL measurements correlated strongly with the actual displacement (r=0.998, Pdisplacement of medial epicondyle humerus fractures. The newly described AXIAL projection more accurately and reliably demonstrated the true displacement while reducing the need for advanced imaging such as computed tomography. This simple view can be easily obtained at a clinic visit, enhancing the surgeon's ability to determine the true displacement.

  10. Borehole tool outrigger arm displacement control mechanism

    International Nuclear Information System (INIS)

    Lee, A.G.

    1985-01-01

    As the outrigger arms of a borehole logging tool are flexed inwardly and outwardly according to the diameter of the borehole opening through which they pass, the corresponding axial displacements of the ends of the arms are controlled to determine the axial positions of the arms relative to the tool. Specifically, as the arm ends move, they are caused to rotate by a cam mechanism. The stiffness of the arms causes the arm ends to rotate in unison, and the exact positions of the arms on the tool are then controlled by the differential movements of the arm ends in the cams

  11. A Differential Monolithically Integrated Inductive Linear Displacement Measurement Microsystem

    Directory of Open Access Journals (Sweden)

    Matija Podhraški

    2016-03-01

    Full Text Available An inductive linear displacement measurement microsystem realized as a monolithic Application-Specific Integrated Circuit (ASIC is presented. The system comprises integrated microtransformers as sensing elements, and analog front-end electronics for signal processing and demodulation, both jointly fabricated in a conventional commercially available four-metal 350-nm CMOS process. The key novelty of the presented system is its full integration, straightforward fabrication, and ease of application, requiring no external light or magnetic field source. Such systems therefore have the possibility of substituting certain conventional position encoder types. The microtransformers are excited by an AC signal in MHz range. The displacement information is modulated into the AC signal by a metal grating scale placed over the microsystem, employing a differential measurement principle. Homodyne mixing is used for the demodulation of the scale displacement information, returned by the ASIC as a DC signal in two quadrature channels allowing the determination of linear position of the target scale. The microsystem design, simulations, and characterization are presented. Various system operating conditions such as frequency, phase, target scale material and distance have been experimentally evaluated. The best results have been achieved at 4 MHz, demonstrating a linear resolution of 20 µm with steel and copper scale, having respective sensitivities of 0.71 V/mm and 0.99 V/mm.

  12. International Monetary Fund and aid displacement.

    Science.gov (United States)

    Stuckler, David; Basu, Sanjay; McKee, Martin

    2011-01-01

    Several recent papers find evidence that global health aid is being diverted to reserves, education, military, or other sectors, and is displacing government spending. This is suggested to occur because ministers of finance have competing, possibly corrupt, priorities and deprive the health sector of resources. Studies have found that development assistance for health routed to governments has a negative impact on health spending and that similar assistance routed to private nongovernmental organizations has a positive impact. An alternative hypothesis is that World Bank and IMF macro-economic policies, which specifically advise governments to divert aid to reserves to cope with aid volatility and keep government spending low, could be causing the displacement of health aid. This article evaluates whether aid displacement was greater when countries undertook a new borrowing program from the IMF between 1996 and 2006. As found in existing studies, for each $1 of development assistance for health, about $0.37 is added to the health system. However, evaluating IMF-borrowing versus non-IMF-borrowing countries reveals that non-borrowers add about $0.45 whereas borrowers add less than $0.01 to the health system. On average, health system spending grew at about half the speed when countries were exposed to the IMF than when they were not. It is important to take account of the political economy of global health finance when interpreting data on financial flows.

  13. Effect of Body Mass Index on Intrafraction Prostate Displacement Monitored by Real-Time Electromagnetic Tracking

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Morris, Mallory N.; Merrick, Gregory S.; Kurko, Brian S.; Murray, Brian C.

    2012-01-01

    Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a “beam on” tag were used in the analysis. There were 21 obese patients, with BMI ≥30 and 45 nonobese patients in the study. Results: Mean displacements were least in the left-right lateral direction (0.56 ± 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 ± 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI ≥30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.

  14. Hydrodynamic Excitation Forces on Floating Structures with Finite Displacements

    DEFF Research Database (Denmark)

    Andersen, Morten Thøtt; Nielsen, Søren R. K.

    2015-01-01

    excitation force is solely a function of time, hence the body is fixed in reference to the wave field. In this paper, the instantaneous position of the body is included in the calculation of the excitation force. Even though the displacement of the structure relative to a characteristic wavelength...

  15. CRANIOFACIAL STRESS PATTERNS AND DISPLACEMENTS AFTER ACTIVATION OF HYRAX DEVICE: FINITE ELEMENT MODELLING

    Directory of Open Access Journals (Sweden)

    Sergei Bosiakov

    2017-12-01

    Full Text Available Rapid maxillary expansion is employed for the treatment of cross-bite and deficiency of transversal dimension of the maxilla in patients with and without cleft of palate and lip. For this procedure, generally, different orthodontic appliances and devices generating significant transversal forces are used. The aim of this study is the finite-element analysis of stresses and displacements of the skull without palate cleft and the skull with unilateral and bilateral cleft after activation of the Hyrax orthodontic device. Two different constructions of the orthodontic device Hyrax with different positions of the screw relative palate are considered. In the first case, the screw is in the occlusal horizontal plane, and in the other, the screw is located near the palate. Activation of the orthodontic device corresponds to the rotation of the screw on one-quarter turn. It is established that the screw position significantly affects the distributions of stresses in skull and displacements of the cranium without palate cleft and with unilateral or bilateral palate cleft. Stresses in the bone structures of the craniums without cleft and with cleft are transferred from the maxilla to the pterygoid plate and pharyngeal tubercle if the screw displaces from the occlusal plane to the palate. Depending on the construction of the orthodontic appliance, the maxilla halves in the transversal plane are unfolded or the whole skull is entirely rotated in the sagittal plane. The stresses patterns and displacements of the skull with bilateral palate cleft are almost unchanged after activation of the orthodontic devices with different positions of the screw, only magnitudes of stresses and displacements are changed. The obtained results can be used for design of orthodontic appliances with the Hyrax screw, as well as for planning of osteotomies during the surgical assistance of the rapid maxillary expansion.

  16. Training improves interobserver reliability for the diagnosis of scaphoid fracture displacement.

    Science.gov (United States)

    Buijze, Geert A; Guitton, Thierry G; van Dijk, C Niek; Ring, David

    2012-07-01

    The diagnosis of displacement in scaphoid fractures is notorious for poor interobserver reliability. We tested whether training can improve interobserver reliability and sensitivity, specificity, and accuracy for the diagnosis of scaphoid fracture displacement on radiographs and CT scans. Sixty-four orthopaedic surgeons rated a set of radiographs and CT scans of 10 displaced and 10 nondisplaced scaphoid fractures for the presence of displacement, using a web-based rating application. Before rating, observers were randomized to a training group (34 observers) and a nontraining group (30 observers). The training group received an online training module before the rating session, and the nontraining group did not. Interobserver reliability for training and nontraining was assessed by Siegel's multirater kappa and the Z-test was used to test for significance. There was a small, but significant difference in the interobserver reliability for displacement ratings in favor of the training group compared with the nontraining group. Ratings of radiographs and CT scans combined resulted in moderate agreement for both groups. The average sensitivity, specificity, and accuracy of diagnosing displacement of scaphoid fractures were, respectively, 83%, 85%, and 84% for the nontraining group and 87%, 86%, and 87% for the training group. Assuming a 5% prevalence of fracture displacement, the positive predictive value was 0.23 in the nontraining group and 0.25 in the training group. The negative predictive value was 0.99 in both groups. Our results suggest training can improve interobserver reliability and sensitivity, specificity and accuracy for the diagnosis of scaphoid fracture displacement, but the improvements are slight. These findings are encouraging for future research regarding interobserver variation and how to reduce it further.

  17. Flow measurement of liquid hydrocarbons with positive displacement meters: the correction for slippage

    International Nuclear Information System (INIS)

    García-Berrocal, Agustín; Montalvo, Cristina; Balbás, Miguel; Blázquez, Juan

    2013-01-01

    In the oil industry, the economical and fiscal impact of the measurements accuracy on the custody transfer operations implies fulfilling strict requirements of legal metrology. In this work, we focus on the positive displacement meters (PD meters) for refined liquid hydrocarbons. The state of the art of the lack of accuracy due to slippage flow in these meters is revised. The slippage flow due to the pressure drop across the device has been calculated analytically by applying the Navier–Stokes equation. No friction with any wall of the slippage channel has been neglected and a more accurate formula than the one found in the literature has been obtained. PD meters are calibrated against a bidirectional prover in order to obtain their meter factor which allows correction of their indications. Instead of the analytical model, an empirical one is proposed to explain the variation of the meter factor of the PD meters with flow rate and temperature for a certain hydrocarbon. The empirical model is based on the historical calibration data, of 9 years on average, of 25 m with four types of refined hydrocarbon. This model has been statistically validated by linear least-squares fitting. By using the model parameters, we can obtain the meter factor corresponding to different conditions of temperature and flow rate from the conditions in which the devices were calibrated. The flow parameter is such that a 10% flow rate variation implies a meter factor variation lower than 0.01%. A rule of thumb value for the temperature parameter is 0.005% per degree Celsius. The model residuals allow surveillance of the device drift and quantifying its contribution to the meter factor uncertainty. The observed drift is 0.09% at 95% confidence level in the analyzed population of meters. (paper)

  18. The use of a displacement device negatively affects the performance of dogs (Canis familiaris) in visible object displacement tasks.

    Science.gov (United States)

    Müller, Corsin A; Riemer, Stefanie; Range, Friederike; Huber, Ludwig

    2014-08-01

    Visible and invisible displacement tasks have been used widely for comparative studies of animals' understanding of object permanence, with evidence accumulating that some species can solve invisible displacement tasks and, thus, reach Piagetian stage 6 of object permanence. In contrast, dogs appear to rely on associative cues, such as the location of the displacement device, during invisible displacement tasks. It remains unclear, however, whether dogs, and other species that failed in invisible displacement tasks, do so because of their inability to form a mental representation of the target object, or simply because of the involvement of a more salient but potentially misleading associative cue, the displacement device. Here we show that the use of a displacement device impairs the performance of dogs also in visible displacement tasks: their search accuracy was significantly lower when a visible displacement was performed with a displacement device, and only two of initially 42 dogs passed the sham-baiting control conditions. The negative influence of the displacement device in visible displacement tasks may be explained by strong associative cues overriding explicit information about the target object's location, reminiscent of an overshadowing effect, and/or object individuation errors as the target object is placed within the displacement device and moves along a spatiotemporally identical trajectory. Our data suggest that a comprehensive appraisal of a species' performance in object permanence tasks should include visible displacement tasks with the same displacement device used in invisible displacements, which typically has not been done in the past.

  19. Displacement of group III, IV, V, and VI impurities in Si by the analyzing beam

    International Nuclear Information System (INIS)

    Wiggers, L.W.; Saris, F.W.

    1978-01-01

    By means of 2MeV He + backscattering and 1.5 MeV H + backscattering and nuclear reaction analysis in combination with the channeling technique displacement of impurity atoms in Si from substitutional into non-substitutional positions under bombardment is studied. In this paper the authors report on the displacement of Ga, Ge, P, As, Sb, Bi, Se, and Te in Si single crystals. It appears that displacement of impurity atoms is not an exception but almost a rule. The only element for which an effect was not found was Ge. Values for the displacement rate were derived and appeared to be, with the exception for Ge, all of the same order of magnitude. (Auth.)

  20. Displacement data assimilation

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, W. Steven [Pacific Northwest Laboratory, Richland, WA 99354 (United States); Venkataramani, Shankar [Department of Mathematics and Program in Applied Mathematics, University of Arizona, Tucson, AZ 85721 (United States); Mariano, Arthur J. [Rosenstiel School of Marine & Atmospheric Science, University of Miami, Miami, FL 33149 (United States); Restrepo, Juan M., E-mail: restrepo@math.oregonstate.edu [Department of Mathematics, Oregon State University, Corvallis, OR 97331 (United States)

    2017-02-01

    We show that modifying a Bayesian data assimilation scheme by incorporating kinematically-consistent displacement corrections produces a scheme that is demonstrably better at estimating partially observed state vectors in a setting where feature information is important. While the displacement transformation is generic, here we implement it within an ensemble Kalman Filter framework and demonstrate its effectiveness in tracking stochastically perturbed vortices.

  1. Displacement cascades in diatomic materials

    International Nuclear Information System (INIS)

    Parkin, D.M.; Coulter, C.A.

    1981-01-01

    A new function, the specified-projectile displacement function p/sub ijk/ (E), is introduced to describe displacement cascades in polyatomic materials. This function describes the specific collision events that produce displacements and hence adds new information not previously available. Calculations of p/sub ijk/ (E) for MgO, Al 2 O 3 and TaO are presented and discussed. Results show that the parameters that have the largest effect on displacement collision events are the PKA energy and the mass ratio of the atom types in the material. It is further shown that the microscopic nature of the displacement events changes over the entire recoil energy range relevant to fusion neutron spectra and that these changes are different in materials whose mass ratio is near one than in those where it is far from one

  2. Displacement of screw-retained splinted and nonsplinted restorations into implants with conical internal connections.

    Science.gov (United States)

    Yilmaz, Burak; Seidt, Jeremy D; Clelland, Nancy L

    2014-01-01

    Variable abutment displacement could potentially affect proximal contacts, incisal edge position, or occlusion of implant-supported prostheses. This study aimed to measure and compare displacements of splinted and nonsplinted restorations into implants featuring internal conical connections as screws were tightened by hand or by torque driver. A stereolithic resin model was printed using computed tomography data from a patient missing mandibular left first and second molars. Two 5.0 × 11-mm implants were placed in the edentulous site using a surgical guide. Two sets (splinted and nonsplinted) of gold screw-retained prostheses were made indirectly to fit the implants in the stereolithic model representing the patient. The axial position of the crowns relative to a fixed location on the model was recorded following hand tightening using the three-dimensional image correlation technique and image correlation software. A pair of high-resolution digital cameras provided a synchronized view of the model during the experiment. Relative crown positions were again recorded after tightening with a torque driver to 25 Ncm. Testing was repeated randomly three times for each set of crowns. Displacement data after torque tightening were compared using a factorial analysis of variance with JMP 9.0 software (SAS) followed by a Tukey-Kramer post hoc test (α = .05). Interproximal contacts were evaluated using an 8-μm tin foil shim after tightening by hand and torque driver. Displacements for splinted and nonsplinted restorations differed only in a buccal direction. The nonsplinted crowns displaced significantly more than splinted crowns. Discernible differences were observed for the tin foil shim when dragged through proximal contacts following hand versus torque tightening. Differences between screw tightening by hand or torque driver should be taken into consideration during laboratory and clinical adjustments to prevent esthetic and functional complications.

  3. Effect of Audio Coaching on Correlation of Abdominal Displacement With Lung Tumor Motion

    International Nuclear Information System (INIS)

    Nakamura, Mitsuhiro; Narita, Yuichiro; Matsuo, Yukinori; Narabayashi, Masaru; Nakata, Manabu; Sawada, Akira; Mizowaki, Takashi; Nagata, Yasushi; Hiraoka, Masahiro

    2009-01-01

    Purpose: To assess the effect of audio coaching on the time-dependent behavior of the correlation between abdominal motion and lung tumor motion and the corresponding lung tumor position mismatches. Methods and Materials: Six patients who had a lung tumor with a motion range >8 mm were enrolled in the present study. Breathing-synchronized fluoroscopy was performed initially without audio coaching, followed by fluoroscopy with recorded audio coaching for multiple days. Two different measurements, anteroposterior abdominal displacement using the real-time positioning management system and superoinferior (SI) lung tumor motion by X-ray fluoroscopy, were performed simultaneously. Their sequential images were recorded using one display system. The lung tumor position was automatically detected with a template matching technique. The relationship between the abdominal and lung tumor motion was analyzed with and without audio coaching. Results: The mean SI tumor displacement was 10.4 mm without audio coaching and increased to 23.0 mm with audio coaching (p < .01). The correlation coefficients ranged from 0.89 to 0.97 with free breathing. Applying audio coaching, the correlation coefficients improved significantly (range, 0.93-0.99; p < .01), and the SI lung tumor position mismatches became larger in 75% of all sessions. Conclusion: Audio coaching served to increase the degree of correlation and make it more reproducible. In addition, the phase shifts between tumor motion and abdominal displacement were improved; however, all patients breathed more deeply, and the SI lung tumor position mismatches became slightly larger with audio coaching than without audio coaching.

  4. Magnetic resonance images of patients with temporomandibular disorders: Prevalence and correlation between disk morphology and displacement

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, Ruana de Oliveira, E-mail: ruana.amaral@hotmail.com [Faculty of Dentistry, Federal University of Juiz de Fora, Minas Gerais (Brazil); Damasceno, Naiana Nolasco de Lima, E-mail: naiananolasketi@yahoo.com.br [Faculty of Dentistry, Federal University of Juiz de Fora, Minas Gerais (Brazil); Azevedo de Souza, Lílian, E-mail: lilianazevedo@msn.com [Faculty of Dentistry, Federal University of Juiz de Fora, Minas Gerais (Brazil); Devito, Karina Lopes, E-mail: karina.devito@ufjf.edu.br [Faculty of Dentistry, Federal University of Juiz de Fora, Minas Gerais (Brazil)

    2013-06-15

    Using magnetic resonance imaging (MRI), this study aimed to evaluate the morphology of the articular disc of the temporomandibular joint (TMJ) in patients with temporomandibular disorder (TMD). There were 218 TMJ of 109 assessed patients; 88 were females and 21 males, and all were diagnosed as symptomatic for temporomandibular disorder. The articular disc positions were classified in the normal position and with anterior disc displacement with and without reduction. Regarding the morphology, the discs were classified as follows: biconcave (normal), biplanar, rounded, biconvex, folded, thickening in the posterior band, thickening in the anterior band and hemiconvex. The results indicated that females were the most affected by morphological changes of the articular disc (p = 0.008/Cramer's V = 0.295). There was no statistical significance when correlating the disc morphology with the sides (right and left). There was a significant correlation between the position and morphology of the articular disc (p < 0.001/Cramer's V = 0.609), and in the normal position of the discs presenting biplanar and biconcave morphologies. In TMJ with anterior displacement of the disc with reduction (ADDR), there was a greater correlation with rounded, hemiconvex and biconvex morphologies. Already in the TMJ with displacement without reduction (ADDWR), there was a higher prevalence of folded discs. It can be concluded that morphological changes in the disc are influenced by the type of displacement, and more serious deformations are associated with ADDWR cases.

  5. Effects of Mach number on pitot-probe displacement in a turbulent boundary layer

    Science.gov (United States)

    Allen, J. M.

    1974-01-01

    Experimental pitot-probe-displacement data have been obtained in a turbulent boundary layer at a local free-stream Mach number of 4.63 and unit Reynolds number of 6.46 million meter. The results of this study were compared with lower Mach number results of previous studies. It was found that small probes showed displacement only, whereas the larger probes showed not only displacement but also distortion of the shape of the boundary-layer profile. The distortion pattern occurred lower in the boundary layer at the higher Mach number than at the the lower Mach number. The maximum distortion occurred when the center of the probe was about one probe diameter off the test surface. For probes in the wall contact position, the indicated Mach numbers were, for all probes tested, close to the true profile. Pitot-probe displacement was found to increase significantly with increasing Mach number.

  6. Field displacement during external radiotherapy in prostatic adenocarcinoma treated with radioactive 198Au implants and external irradiation

    International Nuclear Information System (INIS)

    Lennernaes, B.; Letocha, H.; Rikner, G.; Magnusson, A.; Nilsson, S.

    1995-01-01

    The purpose of this work was to study displacement error and internal movements of the prostate during external beam radiotherapy. Verification films in the frontal (n=194) and lateral (n=64) portals were investigated in 14 patients treated with radioactive 198 Au implants. Displacement errors of two implants were investigated. In seven patients, filling of the rectum and the bladder with contrast medium or isotonic saline was performed during CT investigation for planning purposes to detect movements of the prostate. Most (95%) of the displacement errors were less than 10 mm in the frontal portal and less than 15 mm in the lateral portals. No correlation to the patient's weight was found. The displacement errors were randomly distributed. The spatial relations between the implants were not altered during the treatments. Small movements of the prostate were observed. To conclude, the positioning system employed at present (laser) can be sufficient for the margins used (2 cm). In lateral portals, however, the system did not have the ability to detect a possible systematic displacement error from simulator to accelerator. The intention is to decrease the margins to 1 cm, which will necessitate a better positioning system. (orig.)

  7. Modelling toehold-mediated RNA strand displacement.

    Science.gov (United States)

    Šulc, Petr; Ouldridge, Thomas E; Romano, Flavio; Doye, Jonathan P K; Louis, Ard A

    2015-03-10

    We study the thermodynamics and kinetics of an RNA toehold-mediated strand displacement reaction with a recently developed coarse-grained model of RNA. Strand displacement, during which a single strand displaces a different strand previously bound to a complementary substrate strand, is an essential mechanism in active nucleic acid nanotechnology and has also been hypothesized to occur in vivo. We study the rate of displacement reactions as a function of the length of the toehold and temperature and make two experimentally testable predictions: that the displacement is faster if the toehold is placed at the 5' end of the substrate; and that the displacement slows down with increasing temperature for longer toeholds. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  8. High-level context effects on spatial displacement: the effects of body orientation and language on memory.

    Science.gov (United States)

    Vinson, David W; Abney, Drew H; Dale, Rick; Matlock, Teenie

    2014-01-01

    Three decades of research suggests that cognitive simulation of motion is involved in the comprehension of object location, bodily configuration, and linguistic meaning. For example, the remembered location of an object associated with actual or implied motion is typically displaced in the direction of motion. In this paper, two experiments explore context effects in spatial displacement. They provide a novel approach to estimating the remembered location of an implied motion image by employing a cursor-positioning task. Both experiments examine how the remembered spatial location of a person is influenced by subtle differences in implied motion, specifically, by shifting the orientation of the person's body to face upward or downward, and by pairing the image with motion language that differed on intentionality, fell versus jumped. The results of Experiment 1, a survey-based experiment, suggest that language and body orientation influenced vertical spatial displacement. Results of Experiment 2, a task that used Adobe Flash and Amazon Mechanical Turk, showed consistent effects of body orientation on vertical spatial displacement but no effect of language. Our findings are in line with previous work on spatial displacement that uses a cursor-positioning task with implied motion stimuli. We discuss how different ways of simulating motion can influence spatial memory.

  9. High-level context effects on spatial displacement: The effects of body orientation and language on memory

    Directory of Open Access Journals (Sweden)

    David W Vinson

    2014-07-01

    Full Text Available Three decades of research suggests that cognitive simulation of motion is involved in the comprehension of object location, bodily configuration, and linguistic meaning. For example, the remembered location of an object associated with actual or implied motion is typically displaced in the direction of motion. In this paper, two experiments explore context effects in spatial displacement. They provide a novel approach to estimating the remembered location of an implied motion image by employing a cursor-positioning task. Both experiments examine how the remembered spatial location of a person is influenced by subtle differences in implied motion, specifically, by shifting the orientation of the person’s body to face upward or downward, and by pairing the image with motion language that differed on intentionality, fell versus jumped. The results of Experiment 1, a survey-based experiment, suggest that language and body orientation influenced vertical spatial displacement. Results of Experiment 2, a task that used Adobe Flash and Amazon Mechanical Turk, showed consistent effects of body orientation on vertical spatial displacement but no effect of language. Our findings replicate are in line with previous work on spatial displacement task that used a cursor-positioning task with implied motion stimuli. We discuss how different ways of simulating motion can influence spatial memory.

  10. MRI evaluation of maternal cardiac displacement in pregnancy: implications for cardiopulmonary resuscitation.

    Science.gov (United States)

    Holmes, Signy; Kirkpatrick, Iain D C; Zelop, Carolyn M; Jassal, Davinder S

    2015-09-01

    The purpose of this study was to determine, with the use of cardiac magnetic resonance imaging, whether there is vertical displacement of the heart during pregnancy. Cardiopulmonary resuscitation guidelines during pregnancy recommend placing the hands 2-3 cm higher on the sternum than in nonpregnant individuals. This recommendation is based on the presumption that the heart is displaced superiorly by the diaphragm during the third trimester. Whether there is true cardiac displacement because of the expanding uterus in pregnancy remains unknown. A total of 34 healthy female volunteers 18-35 years old were enrolled prospectively from 2010-2012 at 2 tertiary care centers. The conditions of all participants were evaluated with cardiac magnetic resonance imaging in the one-half left lateral decubitus position during the third trimester of pregnancy and again at a minimum of 3 months after delivery (surrogate for the nonpregnant state). Superior displacement of the heart was determined by measurement of the distance between the inferior aspect of the clavicular heads and the coronary sinus at both time points. The study population included 34 women (mean age, 29 ± 3 years; body mass index, 24 ± 4 kg/m(2)). The mean gestational age at third-trimester imaging was 237 ± 16 days (34 weeks ± 16 days); the mean number of days for postpartum imaging (baseline) was 107 ± 25 days (16 weeks ± 25 days). There was no statistical difference between the cardiac position at baseline (10.1 ± 1.2 cm) and during the third trimester (10.3 ± 1.1 cm; P = .22). Contrary to popular assumption, there is no significant vertical displacement of the heart in the third trimester of pregnancy relative to the nonpregnant state. Accordingly, there is no need to alter hand placement for chest compressions during cardiopulmonary resuscitation in pregnancy. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. MRI of displaced meniscal fragments

    International Nuclear Information System (INIS)

    Dunoski, Brian; Zbojniewicz, Andrew M.; Laor, Tal

    2012-01-01

    A torn meniscus frequently requires surgical fixation or debridement as definitive treatment. Meniscal tears with associated fragment displacement, such as bucket handle and flap tears, can be difficult to recognize and accurately describe on MRI, and displaced fragments can be challenging to identify at surgery. A displaced meniscal fragment can be obscured by synovium or be in a location not usually evaluated at arthroscopy. We present a pictorial essay of meniscal tears with displaced fragments in patients referred to a pediatric hospital in order to increase recognition and accurate interpretation by the radiologist, who in turn can help assist the surgeon in planning appropriate therapy. (orig.)

  12. MRI of displaced meniscal fragments

    Energy Technology Data Exchange (ETDEWEB)

    Dunoski, Brian [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Children' s Hospital of Michigan, Department of Radiology, Detroit, MI (United States); Zbojniewicz, Andrew M.; Laor, Tal [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2012-01-15

    A torn meniscus frequently requires surgical fixation or debridement as definitive treatment. Meniscal tears with associated fragment displacement, such as bucket handle and flap tears, can be difficult to recognize and accurately describe on MRI, and displaced fragments can be challenging to identify at surgery. A displaced meniscal fragment can be obscured by synovium or be in a location not usually evaluated at arthroscopy. We present a pictorial essay of meniscal tears with displaced fragments in patients referred to a pediatric hospital in order to increase recognition and accurate interpretation by the radiologist, who in turn can help assist the surgeon in planning appropriate therapy. (orig.)

  13. Development of a rotary clap mechanism for positive-displacement rotary pumps: Kinematic analysis and working principle

    International Nuclear Information System (INIS)

    Shim, Sung Bo; Kim, Kyeong Uk; Park, Young Jun; Kim, Jong Mun

    2015-01-01

    A five-bar spatial mechanism named as a rotary clap mechanism is developed as a pumping device for positive displacement rotary pumps. The mechanism comprises a driving crank, a shaft link with two pins and two gears mounted on the middle and both ends, two rotors with jaws equally spaced along their circumferences, and two fixed internal gears. As the crank rotates, the gear pin-jointed to the crank rotates about the crank pin and at the same time rotates about the center of the fixed internal gears like a hypo-cyclic gear train. The gear-attached shaft link also rotates about the crank pin and about the fixed internal gears at the same time. This motion of the shaft link makes the pins rotate about the center of the fixed internal gears with a periodically varying radius. Therefore, two rotors driven by the pins rotate with different angular velocities. One rotor alternately leads and lags relative to the other rotor. These lead-lag motions between the two jaws of the rotors, which result in suction and discharge required for pumping, resemble hand clapping from which the mechanism was named. Construction and design parameters of the rotary clap mechanism are introduced, and kinematic analysis of this mechanism is performed. The relationships among design parameters, inherent constraints, and effects of design parameters on the is placement of mechanism are also presented.

  14. Rate of displacement for Jakob Type 1 lateral condyle fractures treated with a cast.

    Science.gov (United States)

    Zale, C; Winthrop, Z A; Hennrikus, W

    2018-04-01

    The aim of this retrospective study is to report the rate of displacement of Jakob Type 1 lateral condyle fractures that were initially treated in a cast. We performed a retrospective review of all patients that were treated for a non-displaced (Jakob Type 1 displaced and were converted to a closed pinning treatment plan with a conversion rate of 8.5%. There was a mean of 13.2 days (4 to 21) between treatment by initial casting and closed pinning. This study demonstrates an 8.5% displacement and conversion rate from cast treatment to closed pinning for initially non-displaced Jakob Type 1 lateral condyle fractures of the humerus. The internal oblique radiograph is most accurate to determine displacement. We recommend obtaining an internal oblique view at initial evaluation and at follow-up in the cast for lateral condyle fractures. To minimize movement at the fracture site, we recommend treating Jakob Type 1 lateral condyle fractures with a long arm cast with the elbow at 90° and the forearm in the supine position with a sling-loop design. IV - retrospective therapeutic study.

  15. Effects of threshold displacement energy on defect production by displacement cascades in α, β and γ-LiAlO2

    International Nuclear Information System (INIS)

    Tsuchihira, H.; Oda, T.; Tanaka, S.

    2013-01-01

    Threshold displacement energy evaluation and a series of displacement cascade simulations in α, β, and γ-LiAlO 2 were performed using molecular dynamics. Threshold displacement energy evaluations indicated that higher absolute ionic charge values and larger densities both increase threshold displacement energy. The displacement cascade simulations suggest that the influence of different crystal structures on the number of interstitial atoms generated in a displacement cascade is explainable almost entirely by the difference of the threshold displacement energy

  16. Effect of displaced versus non-displaced pelvic fractures on long-term racing performance in 31 Thoroughbred racehorses.

    Science.gov (United States)

    Hennessy, S E; Muurlink, M A; Anderson, G A; Puksmann, T N; Whitton, R C

    2013-06-01

    To evaluate the long-term racing prognosis for Thoroughbred racehorses with displaced versus non-displaced fractures of the pelvis identified by scintigraphy. Retrospective case analysis. Medical records of 31 Thoroughbred racehorses presenting to the University of Melbourne Equine Centre with fractures of the pelvis that were identified by scintigraphy were reviewed. Pelvic fracture site was determined and defined as displaced or non-displaced based on ultrasound and/or radiographic findings. Race records were analysed for each horse, with a minimum of 24 months' follow-up, and correlated with fracture type to determine long-term prognosis for racing. Results are expressed as median and range. Fractures at a single site were more common (n = 22) than fractures involving two sites (n = 9) and the ilial wing was the most commonly affected (n = 12). Thoroughbred racehorses with displaced pelvic fractures at any site (n = 12) raced fewer times within 24 months of diagnosis than horses with non-displaced fractures (n = 19) (median 0.5, range 0-13 vs 7, 0-24; P = 0.037), but there was no clear statistical difference in race earnings between the two groups (median A$0, range A$0-$123,250 vs A$14,440, A$0-$325,500, respectively; P = 0.080). Four horses with displaced fractures (33%) were euthanased on humane grounds because of persistent severe pain. When these horses were excluded from the analysis, there were no differences in performance variables between horses with a displaced or non-displaced pelvic fracture. Thoroughbred racehorses with a displaced or non-displaced pelvic fracture that survive the initial post-injury period have a good prognosis for racing. © 2013 The Authors. Australian Veterinary Journal © 2013 Australian Veterinary Association.

  17. A web-based GPS system for displacement monitoring and failure mechanism analysis of reservoir landslide.

    Science.gov (United States)

    Li, Yuanyao; Huang, Jinsong; Jiang, Shui-Hua; Huang, Faming; Chang, Zhilu

    2017-12-07

    It is important to monitor the displacement time series and to explore the failure mechanism of reservoir landslide for early warning. Traditionally, it is a challenge to monitor the landslide displacements real-timely and automatically. Globe Position System (GPS) is considered as the best real-time monitoring technology, however, the accuracies of the landslide displacements monitored by GPS are not assessed effectively. A web-based GPS system is developed to monitor the landslide displacements real-timely and automatically in this study. And the discrete wavelet transform (DWT) is proposed to assess the accuracy of the GPS monitoring displacements. Wangmiao landslide in Three Gorges Reservoir area in China is used as case study. The results show that the web-based GPS system has advantages of high precision, real-time, remote control and automation for landslide monitoring; the Root Mean Square Errors of the monitoring landslide displacements are less than 5 mm. Meanwhile, the results also show that a rapidly falling reservoir water level can trigger the reactivation of Wangmiao landslide. Heavy rainfall is also an important factor, but not a crucial component.

  18. Reliability of internal oblique elbow radiographs for measuring displacement of medial epicondyle humerus fractures: a cadaveric study.

    Science.gov (United States)

    Gottschalk, Hilton P; Bastrom, Tracey P; Edmonds, Eric W

    2013-01-01

    Standard elbow radiographs (AP and lateral views) are not accurate enough to measure true displacement of medial epicondyle fractures of the humerus. The amount of perceived displacement has been used to determine treatment options. This study assesses the utility of internal oblique radiographs for measurement of true displacement in these fractures. A medial epicondyle fracture was created in a cadaveric specimen. Displacement of the fragment (mm) was set at 5, 10, and 15 in line with the vector of the flexor pronator mass. The fragment was sutured temporarily in place. Radiographs were obtained at 0 (AP), 15, 30, 45, 60, 75, and 90 degrees (lateral) of internal rotation, with the elbow in set positions of flexion. This was done with and without radio-opaque markers placed on the fragment and fracture bed. The 45 and 60 degrees internal oblique radiographs were then presented to 5 separate reviewers (of different levels of training) to evaluate intraobserver and interobserver agreement. Change in elbow position did not affect the perceived displacement (P=0.82) with excellent intraobserver reliability (intraclass correlation coefficient range, 0.979 to 0.988) and interobserver agreement of 0.953. The intraclass correlation coefficient for intraobserver reliability on 45 degrees internal oblique films for all groups ranged from 0.985 to 0.998, with interobserver agreement of 0.953. For predicting displacement, the observers were 60% accurate in predicting the true displacement on the 45 degrees internal oblique films and only 35% accurate using the 60 degrees internal oblique view. Standardizing to a 45 degrees internal oblique radiograph of the elbow (regardless of elbow flexion) can augment the treating surgeon's ability to determine true displacement. At this degree of rotation, the measured number can be multiplied by 1.4 to better estimate displacement. The addition of a 45 degrees internal oblique radiograph in medial humeral epicondyle fractures has good

  19. Internal displacement and health among the Palestinian minority in Israel.

    Science.gov (United States)

    Daoud, Nihaya; Shankardass, Ketan; O'Campo, Patricia; Anderson, Kim; Agbaria, Ayman K

    2012-04-01

    Long term health impacts of internal displacement (ID) resulting from political violence are not well documented or understood. One such case is the ID of 300,000-420,000 Palestinian citizens of Israel and their descendants during the Nakba of 1948 (Palestinian Catastrophe). We aim to document the long term health impacts of this ID. We draw on data collected in 2005 from a nationwide random sample of 902 individuals aged 30-70. Research participants were interviewed in person after being selected through a multistage sampling procedure. About 24% of participants reported that either they or their families had been internally displaced. Palestinian internally displaced persons (IDPs), that is, those who were forcibly displaced and dispossessed from their homes and lands during the Nakba and its aftermath, as well as their families and descendants, and who reside within the current borders of Israel, had an odds ratio of 1.45 (95% CI = 1.02-2.07) for poor self-rated health (SRH) compared to non-IDPs after controlling for demographic, socioeconomic and psychosocial factors. No difference was found between IDPs and non-IDPs in limiting longstanding illness following control for confounders. Low socioeconomic position and chronic stress were significantly related to ID and to SRH. Our findings suggest adverse long term health impacts of the Nakba on the IDPs when compared to non-IDPs. We propose that these disparities might stem from IDPs' unhealed post-traumatic scars from the Nakba, or from becoming a marginalized minority within their own society due to their displacement and loss of collective identity. Given these long term health consequences, we conclude that displacement should be addressed with health and social policies for IDPs. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Fundamentals of displacement production in irradiated metals

    International Nuclear Information System (INIS)

    Doran, D.G.

    1975-09-01

    Radioinduced displacement damage in metals is described. Discussions are included on the displacement event itself, calculation of displacement rates in general, the manner in which different types of radiation interact with metals to produce displacements, the similarities and differences in the types of damage produced, the current status of computer simulations of displacement cascades, experimental evidence regarding cascades, and aspects of correlating damage produced by different types of radiation

  1. Modelling Toehold-Mediated RNA Strand Displacement

    OpenAIRE

    Šulc, Petr; Ouldridge, Thomas E.; Romano, Flavio; Doye, Jonathan P.K.; Louis, Ard A.

    2015-01-01

    We study the thermodynamics and kinetics of an RNA toehold-mediated strand displacement reaction with a recently developed coarse-grained model of RNA. Strand displacement, during which a single strand displaces a different strand previously bound to a complementary substrate strand, is an essential mechanism in active nucleic acid nanotechnology and has also been hypothesized to occur in vivo. We study the rate of displacement reactions as a function of the length of the toehold and temperat...

  2. Displacement cross sections and PKA spectra: tables and applications

    International Nuclear Information System (INIS)

    Doran, D.G.; Graves, N.J.

    1976-12-01

    Damage energy cross sections to 20 MeV are given for aluminum, vanadium, chromium, iron, nickel, copper, zirconium, niobium, molybdenum, tantalum, tungsten, lead, and 18Cr10Ni stainless steel. They are based on ENDF/B-IV nuclear data and the Lindhard energy partition model. Primary knockon atom (PKA) spectra are given for aluminum, iron, niobium, tantalum, and lead for neutron energies up to 15 MeV at approximately one-quarter lethargy intervals. The contributions of various reactions to both the displacement cross sections (taken to be proportional to the damage energy cross sections) and the PKA spectra are presented graphically. Spectral-averaged values of the displacement cross sections are given for several spectra, including approximate maps for the Experimental Breeder Reactor-II (EBR-II) and several positions in the Fast Test Reactor (FTR). Flux values are included to permit estimation of displacement rates. Graphs show integral PKA spectra for the five metals listed above for neutron spectra corresponding to locations in the EBR-II, the High Flux Isotope Reactor (HFIR), and a conceptual fusion reactor (UWMAK-I). Detailed calculations are given only for cases not previously documented. Uncertainty estimates are included

  3. Measurement of interfacial displacement of a liquid film in microchannels using laser focus displacement meter

    International Nuclear Information System (INIS)

    Hazuku, Tatsuya; Fukamachi, Norihiro; Takamasa, Tomoji; Hibiki, Takashi

    2004-01-01

    This paper presents a new method for measuring the interfacial displacement of a liquid film in microchannels using a laser focus displacement meter (LFD). The purpose of the study is to clarify the effectiveness of the new method for obtaining detailed information concerning interfacial displacement, especially in the case of a thin liquid film, in micro- and mini-channels. To prevent the tube wall signal from disturbing that of the gas-liquid interface, a fluorocarbon tube with water box was used; the refraction index of this device is same as that for water. With this method, accurate instantaneous measurements of interfacial displacement of the liquid film were achieved. The error caused by refraction of the laser beam passing through the acrylic water box and fluorocarbon tube was estimated analytically and experimentally. The formulated analytical equation can estimate the real interface displacement using measured displacement in a fluorocarbon tube of 25 μm to 2.0 mm I.D. A preliminary test using fluorocarbon tubes of 1 and 2 mm I.D. showed that the corrected interface displacement calculated by the equation agreed with real displacement within a 1% margin of error. It was also confirmed that the LFD in the system could measure a liquid film of 0.25 μm at the thinnest. We made simultaneous measurements of the interface in fluorocarbon tubes of 0.5 and 1 mm I.D. using the LFD and a high-speed video camera with a microscope. These showed that the LFD could measure the interface of a liquid film with high spatial and temporal resolution during annular, slug, and piston flow regimes. The data also clarified the existence of a thin liquid film less than 1 μm in thickness in slug and annular flow regions. (author)

  4. Inducible displacement of cemented tibial components ten years after total knee arthroplasty.

    Science.gov (United States)

    Lam Tin Cheung, K; Lanting, B A; McCalden, R W; Yuan, X; MacDonald, S J; Naudie, D D; Teeter, M G

    2018-02-01

    The aim of this study was to evaluate the long-term inducible displacement of cemented tibial components ten years after total knee arthroplasty (TKA). A total of 15 patients from a previously reported prospective trial of fixation using radiostereometric analysis (RSA) were examined at a mean of 11 years (10 to 11) postoperatively. Longitudinal supine RSA examinations were acquired at one week, one year, and two years postoperatively and at final follow-up. Weight-bearing RSA examinations were also undertaken with the operated lower limb in neutral and in maximum internal rotation positions. Maximum total point motion (MTPM) was calculated for the longitudinal and inducible displacement examinations (supine versus standing, standing versus internal rotation, and supine versus standing with internal rotation). All patients showed some inducible displacement. Two patients with radiolucent lines had greater mean standing-supine MTPM displacement (1.35; sd 0.38) compared with the remaining patients (0.68; sd 0.36). These two patients also had a greater mean longitudinal MTPM at ten years (0.64; sd 0.50) compared with the remaining patients (0.39; sd 0.13 mm). Small inducible displacements in well-fixed cemented tibial components were seen ten years postoperatively, of a similar magnitude to that which has been reported for well-fixed components one to two years postoperatively. Greater displacements were found in components with radiolucent lines. Cite this article: Bone Joint J 2018;100-B:170-5. ©2018 The British Editorial Society of Bone & Joint Surgery.

  5. Measurement of liquid film thickness by optical fluorescence and its application to an oscillating piston positive displacement flowmeter

    International Nuclear Information System (INIS)

    Morton, Charlotte E; Baker, Roger C; Hutchings, Ian M

    2011-01-01

    The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 µm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required

  6. Condylar position on the lateral individualized corrected tomography in internal derangement of temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keun Min; Hwang, Eui Hwan; Lee, Sang Rae [College of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2002-06-15

    To examine the possible relationship between condylar position and disk displacement in the temporomandibular joint. 79 temporomandibular joints in 40 patients having temporomandibular disorders were classified into three categories: no disk displacement (NDD), disk displacement with reduction (DDWR), and disk displacement without reduction (DDWOR). Disk positions were assessed from clinical and MRI findings. The relationship between the three categories and condylar positions was evaluated using lateral individualized corrected tomography. Clinical findings regarding the relationship between condyle and disk positions having anterior, centric, and posterior positions were 27%, 27%, and 46%, respectively, in NDD, 43%, 17%, and 40%, respectively, in DDWR, and 44%, 22%, and 34%, respectively, in DDWOR. There were no significant differences in condylar positions between each of the groups (P>0.05). In the relationship between condyle and disk positions with MRI findings, anterior, centric, and posterior positions were 38%, 38%, and 24%, respectively, in NDD, 29%, 21%, and 50%, respectively, in DDWR, and 44%, 9%, and 47% respectively, in DDWOR. There were significant differences in the condylar positions when MRI was utilized (P<0.05). There was a significant correlation between the condyle and disk positions with MRI findings on lateral individualized corrected tomography.

  7. Quantification of disc displacement in internal derangement of the temporomandibular joint using magnetic resonance imaging.

    Science.gov (United States)

    Arayasantiparb, Raweewan; Tsuchimochi, Makoto

    2010-02-01

    Many measures have been developed to determine the extent of disc displacement in internal derangements of the temporomandibular joint (TMJ) using magnetic resonance imaging. The purpose of this study was to develop a quantitative method of analyzing disc position and to evaluate the positions of the disc in internal derangements of the TMJ (group 1, with reduction; group 2, without reduction). Magnetic resonance images of 150 TMJs in 20 healthy volunteers and 55 patients with internal derangements were evaluated. The anatomical points of interest of the TMJ, including the anterior (DA) and posterior (DP) points of the disc, were marked on parasagittal magnetic resonance images of the TMJ disc taken in both the closed- and the open-mouth positions. All points were recorded using an x-y coordinate system, with reference to a referral line. In the closed-mouth position, the DP in patients in group 1 was situated in a more-anterior direction than the DP in volunteers. The DP in group 2 was located further anterior and inferior than the DP in group 1. However, the position of the DA did not differ between group 1 and group 2. In the open-mouth position, the DP was displaced anteroinferiorly to a greater extent in group 2 than in group 1 (one-way ANOVA, followed by Scheffe's test; P displaced TMJ discs revealed no significant difference. In conclusion, most of our results quantitatively support previously reported findings in imaging, surgical, and histopathological studies of TMJ internal derangement. We suggest that our measure of disc position of the TMJ would be useful to assess the status and response to treatment of internal derangements of the TMJ.

  8. Displacement functions for diatomic materials

    International Nuclear Information System (INIS)

    Panrkin, D.M.; Coulter, C.A.

    1979-01-01

    An extension of the methods of Lindhard et at. was used to calculate the total displacement function n/sub ij/(E) for a number of diatomic materials, where n/sub ij/(E) is defined to be the average number of atoms of type j which are displaced from their sites in a displacement cascade initiated by a PKA of type i and energy E. From the n/sub ij/(E) one can calculate the fraction n/sub ij/(E) of the displacements produced by a type i PKA with energy E which are of type j. Values of the n/sub ij/ for MgO, CaO, Al 2 O 3 , and TaO are presented. It is shown that for diatomic materials with mass ratios reasonably near one (e.g., MgO, Al 2 O 3 ) and equal displacement thresholds for the two species the n/sub ij/ become independent of the PKA type i at energies only a few times threshold. However, for larger mass ratios the n/sub ij/ do not become independent of i until much larger, energies are reached - e.g. > 10 5 eV for TaO. In addition, it is found that the n/sub ij/ depend sensitively on the displacement thresholds, with very dramatic charges occuring when the two thresholds become significantly different from one another

  9. Development of Displacement Gages Exposed to Solid Rocket Motor Internal Environments

    Science.gov (United States)

    Bolton, D. E.; Cook, D. J.

    2003-01-01

    The Space Shuttle Reusable Solid Rocket Motor (RSRM) has three non-vented segment-to-segment case field joints. These joints use an interference fit J-joint that is bonded at assembly with a Pressure Sensitive Adhesive (PSA) inboard of redundant O-ring seals. Full-scale motor and sub-scale test article experience has shown that the ability to preclude gas leakage past the J-joint is a function of PSA type, joint moisture from pre-assembly humidity exposure, and the magnitude of joint displacement during motor operation. To more accurately determine the axial displacements at the J-joints, two thermally durable displacement gages (one mechanical and one electrical) were designed and developed. The mechanical displacement gage concept was generated first as a non-electrical, self-contained gage to capture the maximum magnitude of the J-joint motion. When it became feasible, the electrical displacement gage concept was generated second as a real-time linear displacement gage. Both of these gages were refined in development testing that included hot internal solid rocket motor environments and simulated vibration environments. As a result of this gage development effort, joint motions have been measured in static fired RSRM J-joints where intentional venting was produced (Flight Support Motor #8, FSM-8) and nominal non-vented behavior occurred (FSM-9 and FSM-10). This data gives new insight into the nominal characteristics of the three case J-joint positions (forward, center and aft) and characteristics of some case J-joints that became vented during motor operation. The data supports previous structural model predictions. These gages will also be useful in evaluating J-joint motion differences in a five-segment Space Shuttle solid rocket motor.

  10. Conflict, displacement and health in the Middle East.

    Science.gov (United States)

    Mowafi, Hani

    2011-01-01

    Displacement is a hallmark of modern humanitarian emergencies. Displacement itself is a traumatic event that can result in illness or death. Survivors face challenges including lack of adequate shelter, decreased access to health services, food insecurity, loss of livelihoods, social marginalisation as well as economic and sexual exploitation. Displacement takes many forms in the Middle East and the Arab World. Historical conflicts have resulted in long-term displacement of Palestinians. Internal conflicts have driven millions of Somalis and Sudanese from their homes. Iraqis have been displaced throughout the region by invasion and civil strife. In addition, large numbers of migrants transit Middle Eastern countries or live there illegally and suffer similar conditions as forcibly displaced people. Displacement in the Middle East is an urban phenomenon. Many displaced people live hidden among host country populations in poor urban neighbourhoods - often without legal status. This represents a challenge for groups attempting to access displaced populations. Furthermore, health information systems in host countries often do not collect data on displaced people, making it difficult to gather data needed to target interventions towards these vulnerable populations. The following is a discussion of the health impacts of conflict and displacement in the Middle East. A review was conducted of published literature on migration and displacement in the region. Different cases are discussed with an emphasis on the recent, large-scale and urban displacement of Iraqis to illustrate aspects of displacement in this region.

  11. Gender-based violence in conflict and displacement: qualitative findings from displaced women in Colombia.

    Science.gov (United States)

    Wirtz, Andrea L; Pham, Kiemanh; Glass, Nancy; Loochkartt, Saskia; Kidane, Teemar; Cuspoca, Decssy; Rubenstein, Leonard S; Singh, Sonal; Vu, Alexander

    2014-01-01

    Gender-based violence (GBV) is prevalent among, though not specific to, conflict affected populations and related to multifarious levels of vulnerability of conflict and displacement. Colombia has been marked with decades of conflict, with an estimated 5.2 million internally displaced persons (IDPs) and ongoing violence. We conducted qualitative research to understand the contexts of conflict, displacement and dynamics with GBV. This as part of a multi-phase, mixed method study, in collaboration with UNHCR, to develop a screening tool to confidentially identify cases of GBV for referral among IDP women who were survivors of GBV. Qualitative research was used to identify the range of GBV, perpetrators, contexts in conflict and displacement, barriers to reporting and service uptake, as well as to understand experiences of service providers. Thirty-five female IDPs, aged 18 years and older, who self-identified as survivors of GBV were enrolled for in-depth interviews in San Jose de Guaviare and Quibdo, Colombia in June 2012. Thirty-one service providers participated in six focus group discussions and four interviews across these sites. Survivors described a range of GBV across conflict and displacement settings. Armed actors in conflict settings perpetrated threats of violence and harm to family members, child recruitment, and, to a lesser degree, rape and forced abortion. Opportunistic violence, including abduction, rape, and few accounts of trafficking were more commonly reported to occur in the displacement setting, often perpetrated by unknown individuals. Intrafamilial violence, intimate partner violence, including physical and sexual violence and reproductive control were salient across settings and may be exacerbated by conflict and displacement. Barriers to reporting and services seeking were reported by survivors and providers alike. Findings highlight the need for early identification of GBV cases, with emphasis on confidential approaches and active

  12. Displacement sensing system and method

    Science.gov (United States)

    VunKannon, Jr., Robert S

    2006-08-08

    A displacement sensing system and method addresses demanding requirements for high precision sensing of displacement of a shaft, for use typically in a linear electro-dynamic machine, having low failure rates over multi-year unattended operation in hostile environments. Applications include outer space travel by spacecraft having high-temperature, sealed environments without opportunity for servicing over many years of operation. The displacement sensing system uses a three coil sensor configuration, including a reference and sense coils, to provide a pair of ratio-metric signals, which are inputted into a synchronous comparison circuit, which is synchronously processed for a resultant displacement determination. The pair of ratio-metric signals are similarly affected by environmental conditions so that the comparison circuit is able to subtract or nullify environmental conditions that would otherwise cause changes in accuracy to occur.

  13. MR imaging characteristics and clinical symptoms related to displaced meniscal flap tears

    Energy Technology Data Exchange (ETDEWEB)

    Lance, Valentin; Heilmeier, Ursula R.; Joseph, Gabby B.; Steinbach, Lynne; Link, Thomas M. [University of California, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Ma, Benjamin [University of California, Department of Orthopedic Surgery and Sports Medicine, San Francisco (United States)

    2014-11-16

    The purpose of our study was (1) to analyze the flap tear location, direction of displacement and size on magnetic resonance (MR) imaging, (2) to describe associated knee abnormalities including presence of effusion, synovitis, bone marrow edema pattern or ligamentous tear, and (3) to assess clinical findings found with flap tears, including the pain score, and determine differences between operative and nonoperative groups. A retrospective radiology database search over the last 3 years identified 238 patients with flap tears, of which ultimately 58 with isolated flap tears were included after exclusion of patients with other significant knee internal derangement, severe degenerative change or prior surgery. MR studies of the knee were analyzed by two radiologists. Imaging characteristics were correlated with associated knee abnormalities and clinical findings. Statistical analysis employed linear and logistic regression models. Inter- and intrareader reliability was calculated. The medial meniscus was the most common site of flap tears (52/60, 87 %), with inferior displacement (47/60, 78 %). The degree of tibial cartilage loss had a positive correlation with the visual analog pain scale (p = 0.03). Patients who underwent arthroscopy were younger than those who did not (p = 0.01) and more likely to have a positive clinical McMurray test (p = 0.01). Medially and inferiorly displaced flap tears are the most common tear pattern. Those undergoing arthroscopy are more likely to have positive meniscal signs on clinical examination. A greater degree of cartilage loss involving the tibia on MR imaging was associated with increasing visual analog pain scores. (orig.)

  14. MR imaging characteristics and clinical symptoms related to displaced meniscal flap tears

    International Nuclear Information System (INIS)

    Lance, Valentin; Heilmeier, Ursula R.; Joseph, Gabby B.; Steinbach, Lynne; Link, Thomas M.; Ma, Benjamin

    2015-01-01

    The purpose of our study was (1) to analyze the flap tear location, direction of displacement and size on magnetic resonance (MR) imaging, (2) to describe associated knee abnormalities including presence of effusion, synovitis, bone marrow edema pattern or ligamentous tear, and (3) to assess clinical findings found with flap tears, including the pain score, and determine differences between operative and nonoperative groups. A retrospective radiology database search over the last 3 years identified 238 patients with flap tears, of which ultimately 58 with isolated flap tears were included after exclusion of patients with other significant knee internal derangement, severe degenerative change or prior surgery. MR studies of the knee were analyzed by two radiologists. Imaging characteristics were correlated with associated knee abnormalities and clinical findings. Statistical analysis employed linear and logistic regression models. Inter- and intrareader reliability was calculated. The medial meniscus was the most common site of flap tears (52/60, 87 %), with inferior displacement (47/60, 78 %). The degree of tibial cartilage loss had a positive correlation with the visual analog pain scale (p = 0.03). Patients who underwent arthroscopy were younger than those who did not (p = 0.01) and more likely to have a positive clinical McMurray test (p = 0.01). Medially and inferiorly displaced flap tears are the most common tear pattern. Those undergoing arthroscopy are more likely to have positive meniscal signs on clinical examination. A greater degree of cartilage loss involving the tibia on MR imaging was associated with increasing visual analog pain scores. (orig.)

  15. Position indicating device

    International Nuclear Information System (INIS)

    Fellchenfeld, M.M.; Connors, G.R.

    1987-01-01

    This patent describes a position indicating device for producing an indication of the position of a displaceable structure comprising: a position representing member mounted for movement in response to displacement of the structure; sensing elements spaced apart along the defined path such that each element is associated with a respective location along the defined path; means operatively coupling the elements into respective pairs of elements, having, for each pair of elements, an output producing a signal only when a single element of its respective pair is responding to the presence of the member; signal producing members each operative for producing a signal representing a predetermined logic state in response to a predetermined input signal, the number of the signal producing members being smaller than the number of the sensing elements; and circuit means operatively connecting the outputs to the signal producing members for causing a signal at each output to produce a predetermined input signal at a corresponding signal producing member and for causing a predetermined input signal to be produced at least one the signal producing member whenever a signal is present at either one of at least two of the outputs

  16. Effects of Fault Displacement on Emplacement Drifts

    International Nuclear Information System (INIS)

    Duan, F.

    2000-01-01

    The purpose of this analysis is to evaluate potential effects of fault displacement on emplacement drifts, including drip shields and waste packages emplaced in emplacement drifts. The output from this analysis not only provides data for the evaluation of long-term drift stability but also supports the Engineered Barrier System (EBS) process model report (PMR) and Disruptive Events Report currently under development. The primary scope of this analysis includes (1) examining fault displacement effects in terms of induced stresses and displacements in the rock mass surrounding an emplacement drift and (2 ) predicting fault displacement effects on the drip shield and waste package. The magnitude of the fault displacement analyzed in this analysis bounds the mean fault displacement corresponding to an annual frequency of exceedance of 10 -5 adopted for the preclosure period of the repository and also supports the postclosure performance assessment. This analysis is performed following the development plan prepared for analyzing effects of fault displacement on emplacement drifts (CRWMS M and O 2000). The analysis will begin with the identification and preparation of requirements, criteria, and inputs. A literature survey on accommodating fault displacements encountered in underground structures such as buried oil and gas pipelines will be conducted. For a given fault displacement, the least favorable scenario in term of the spatial relation of a fault to an emplacement drift is chosen, and the analysis is then performed analytically. Based on the analysis results, conclusions are made regarding the effects and consequences of fault displacement on emplacement drifts. Specifically, the analysis will discuss loads which can be induced by fault displacement on emplacement drifts, drip shield and/or waste packages during the time period of postclosure

  17. Can positional MRI predict dynamic changes in the medial plantar arch?

    DEFF Research Database (Denmark)

    Johannsen, Finn E; Hansen, Philip; Stallknecht, Sandra

    2016-01-01

    BACKGROUND: Positional MRI (pMRI) allows for three-dimensional visual assessment of navicular position. In this exploratory pilot study pMRI was validated against a stretch sensor device, which measures movement of the medial plantar arch. We hypothesized that a combined pMRI measure incorporating...... and c) standing position with addition of 10 % body weight during static loading of the foot. Stretch sensor measurements were also performed during barefoot walking. RESULTS: The total change in navicular position measured by pMRI was 10.3 mm (CI: 7.0 to 13.5 mm). No further displacement occurred when.......08). CONCLUSIONS: Total navicular bone displacements determined by pMRI showed concurrent validity with stretch sensor measurements but only so under static loading conditions. Although assessment of total navicular displacement by combining concomitant vertical and medial navicular bone movements would appear...

  18. High-displacement spiral piezoelectric actuators

    Science.gov (United States)

    Mohammadi, F.; Kholkin, A. L.; Jadidian, B.; Safari, A.

    1999-10-01

    A high-displacement piezoelectric actuator, employing spiral geometry of a curved piezoelectric strip is described. The monolithic actuators are fabricated using a layered manufacturing technique, fused deposition of ceramics, which is capable of prototyping electroceramic components with complex shapes. The spiral actuators (2-3 cm in diameter) consisted of 4-5 turns of a lead zirconate titanate ceramic strip with an effective length up to 28 cm. The width was varied from 0.9 to 1.75 mm with a height of 3 mm. When driven by the electric field applied across the width of the spiral wall, the tip of the actuator was found to displace in both radial and tangential directions. The tangential displacement of the tip was about 210 μm under the field of 5 kV/cm. Both the displacement and resonant frequency of the spirals could be tailored by changing the effective length and wall width. The blocking force of the actuator in tangential direction was about 1 N under the field of 5 kV/cm. These properties are advantageous for high-displacement low-force applications where bimorph or monomorph actuators are currently employed.

  19. Flight experience and the perception of pitch angular displacements in a gondola centrifuge.

    Science.gov (United States)

    Tribukait, Arne; Eiken, Ola

    2012-05-01

    It has been shown that flight experience may induce an adaptation of the vestibular system. The aim of the present work was to elucidate whether pilots, in comparison with non-pilots, have an increased responsiveness to angular displacement canal stimuli in the pitch plane during a conflict between the otolith organs and the semicircular canals. In a large swing-out gondola centrifuge, eight non-pilots, eight fighter pilots, and eight helicopter pilots underwent three runs (2 G, 5 min) heading forward, centripetally, and centrifugally. The direction of the gravitoinertial force was constant with respect to the subject. The visually perceived eye level (VPEL) was measured in darkness by means of an adjustable luminous dot. In the forward position the three groups produced similar results. After acceleration there was a sensation of backward tilt and an increasing depression of VPEL. This effect was smaller in the centripetal position and larger in the centrifugal position. The difference in VPEL between the opposite positions constitutes a measure of the ability to sense the pitch angular displacement canal stimulus related to the swing out of the gondola (60 degrees). This difference was most pronounced initially at the 2-G plateau (mean +/- SD): 13.5 +/- 12.9 degrees (non-pilots), 41.6 +/- 21.1 degrees (fighter pilots), and 19.5 +/- 14.0 degrees (helicopter pilots). There was no significant difference between non-pilots and helicopter pilots. Fighter pilots differed significantly from both non-pilots and helicopter pilots. Vestibular learning effects of flying may be revealed in a centrifuge. Fighter pilots had an increased ability, as compared to non-pilots and helicopter pilots, to perceive pitch angular displacements.

  20. On the improvement of heterodyne displacement interferometry : Enhancing measurement linearity and system modularity

    NARCIS (Netherlands)

    Meskers, A.J.H.

    2014-01-01

    Lithographic exposure equipment for integrated circuit manufacturing requires ever more accurate position measurement systems, which is currently led by the advent of Extreme UltraViolet (EUV)-lithography machines. This PhD-research describes an interferometric displacement measurement system that

  1. The relationship between the TMJ internal derangement state including rotational displacement and perforation and the clinical characteristics

    International Nuclear Information System (INIS)

    Jeong, Hwan Seok; You Dong Soo

    1998-01-01

    This study was designed to reveal the correlationship between the internal derangement state of TMJ and clinical characteristics including pain and mandibular dysfuntion. One hundred and twenty five subjects with TMJ signs and symptoms were chosen for two years. The level of pain and mandibular dysfuntion were evaluated by Visual Analog Scale (VAS) and Craniomandibular Index (CMI). The diagnostic categories of TMJ internal derangement were determined by arthrography and they included normal disc position, anterior disc displacement with reduction (ADDR), rotational disc displacement with reduction (RDDR), andterior disc displacement without reduction (ADDNR), and rotational disc displacement without reduction (RDDNR). Also disc perforation was used as a criteria to divide the diagnostic subgroups. The obtained results were as follows ; 1. The patient distribution of each group was 5 in normal disc position (4%), 40 in ADDR (32%), 30 in RDDR (24%), 34 in ADDNR (27%), and 16 in RDDNR (13%). 2. Perforation was observed in 8% of ADDR, 10% of RDDR, 32% of ADDNR, and 19% of RDDNR. 3. CMI of perforation group was higher than that of reduction or normal group(p 0.05).

  2. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    Science.gov (United States)

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  3. Micropillar displacements by cell traction forces are mechanically correlated with nuclear dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qingsen; Makhija, Ekta; Hameed, F.M. [Mechanobiology Institute, National University of Singapore (Singapore); Shivashankar, G.V., E-mail: shiva.gvs@gmail.com [Mechanobiology Institute, National University of Singapore (Singapore); Department of Biological Sciences, National University of Singapore (Singapore)

    2015-05-29

    Cells sense physical cues at the level of focal adhesions and transduce them to the nucleus by biochemical and mechanical pathways. While the molecular intermediates in the mechanical links have been well studied, their dynamic coupling is poorly understood. In this study, fibroblast cells were adhered to micropillar arrays to probe correlations in the physical coupling between focal adhesions and nucleus. For this, we used novel imaging setup to simultaneously visualize micropillar deflections and EGFP labeled chromatin structure at high spatial and temporal resolution. We observed that micropillar deflections, depending on their relative positions, were positively or negatively correlated to nuclear and heterochromatin movements. Our results measuring the time scales between micropillar deflections and nucleus centroid displacement are suggestive of a strong elastic coupling that mediates differential force transmission to the nucleus. - Highlights: • Correlation between focal adhesions and nucleus studied using novel imaging setup. • Micropillar and nuclear displacements were measured at high resolution. • Correlation timescales show strong elastic coupling between cell edge and nucleus.

  4. Multi-GNSS high-rate RTK, PPP and novel direct phase observation processing method: application to precise dynamic displacement detection

    Science.gov (United States)

    Paziewski, Jacek; Sieradzki, Rafal; Baryla, Radoslaw

    2018-03-01

    This paper provides the methodology and performance assessment of multi-GNSS signal processing for the detection of small-scale high-rate dynamic displacements. For this purpose, we used methods of relative (RTK) and absolute positioning (PPP), and a novel direct signal processing approach. The first two methods are recognized as providing accurate information on position in many navigation and surveying applications. The latter is an innovative method for dynamic displacement determination with the use of GNSS phase signal processing. This method is based on the developed functional model with parametrized epoch-wise topocentric relative coordinates derived from filtered GNSS observations. Current regular kinematic PPP positioning, as well as medium/long range RTK, may not offer coordinate estimates with subcentimeter precision. Thus, extended processing strategies of absolute and relative GNSS positioning have been developed and applied for displacement detection. The study also aimed to comparatively analyze the developed methods as well as to analyze the impact of combined GPS and BDS processing and the dependence of the results of the relative methods on the baseline length. All the methods were implemented with in-house developed software allowing for high-rate precise GNSS positioning and signal processing. The phase and pseudorange observations collected with a rate of 50 Hz during the field test served as the experiment’s data set. The displacements at the rover station were triggered in the horizontal plane using a device which was designed and constructed to ensure a periodic motion of GNSS antenna with an amplitude of ~3 cm and a frequency of ~4.5 Hz. Finally, a medium range RTK, PPP, and direct phase observation processing method demonstrated the capability of providing reliable and consistent results with the precision of the determined dynamic displacements at the millimeter level. Specifically, the research shows that the standard deviation of

  5. H-M bearing capacity of a modified suction caisson determined by using load-/displacement-controlled methods

    Science.gov (United States)

    Zhang, Yu-kun; Gao, Yu-feng; Li, Da-yong; Mahfouz, Ali H.

    2016-12-01

    This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs (modified suction caissons) in the saturated marine fine sand. The lateral loads were applied under load- and displacement-controlled methods at the loading eccentricity ratios of 1.5, 2.0 and 2.5. Results show that, in the displacement-controlled test, the deflection-softening behavior of load-deflection curves for MSCs was observed, and the softening degree of the load-deflection response increased with the increasing external skirt length or the decreasing loading eccentricity. It was also found that the rotation center of the MSC at failure determined by the load-controlled method is slightly lower than that by the displacement-controlled method. The calculated MSC capacity based on the rotation center position in serviceability limit state is relatively conservative, compared with the calculated capacity based on the rotation center position in the ultimate limit state. In the limit state, the passive earth pressures opposite the loading direction under load- and displacement-controlled methods decrease by 46% and 74% corresponding to peak values, respectively; however, the passive earth pressures in the loading direction at failure only decrease by approximately 3% and 7%, compared with their peak values.

  6. Improving Students' Understanding of Waves by Plotting a Displacement-Time Graph in Class

    Science.gov (United States)

    Wei, Yajun

    2012-04-01

    The topic of waves is one that many high school physics students find difficult to understand. This is especially true when using some A-level textbooks1,2used in the U.K., where the concept of waves is introduced prior to the concept of simple harmonic oscillations. One of the challenges my students encounter is understanding the difference between displacement-time graphs and displacement-position graphs. Many students wonder why these two graphs have the same sinusoidal shape. Having the students use multimedia simulations allows them to see, in a hands-on fashion, the relationship between the two graphs.

  7. Rod displacement measurements by x-ray CT and its impact on thermal-hydraulics in tight-lattice rod bundle (Joint research)

    International Nuclear Information System (INIS)

    Mitsutake, Toru; Misawa, Takeharu; Kureta, Masatoshi; Akimoto, Hajime

    2005-06-01

    In tight-lattice simulated rod bundles with about 1 mm gap between rods, a rod displacement might affect thermal-hydraulic characteristics since the displacement has a strong impact on the flow area change along the heated section. It should be important to estimate how large the rod position displacement could quantitatively affect critical power for the tight-lattice rod bundle from the point of improvement of prediction capability of subchannel analysis. In the present study, the inside-structure observation of the simulated seven-rod bundle of Reduced Moderation Water Reactor (RMWR) was made through the whole length of the test assembly. Based on the measured rod position data, the relation between the rod position displacement and the heat transfer characteristics was investigated experimentally and through the two kinds of subchannel analysis, the nominal rod position case and the measured rod position case, the effect on the predicted critical power was estimated. The high-energy X-ray computer tomograph (CT) of Fuels Monitoring Facilities (FMF) at the O-arai Engineering Center in Japan Nuclear Cycle Institute (JNC) was applied for the inside-structure observation of the test assembly. The CT view of the cross sections within the test assembly assured the hexagonal rod position arrangement was almost the same as expected by design. The measured data with the X-ray CT facility showed that all rod displacements were small, 0.5 millimeters at maximum and 0.2 millimeters in average. In the heat transfer experiments for the seven-rod bundle, the boiling transition (BT) position and the rod surface temperature behavior was measured. All thermocouples on the center rod downstream from the BT-onset axial height showed almost simultaneous temperature increase due to BT. And the thermocouples located on the same axial heights showed quite similar time-variation behaviors in the vapor cooling heat transfer regime. These results demonstrated the effect of the

  8. A novel capacitive absolute positioning sensor based on time grating with nanometer resolution

    Science.gov (United States)

    Pu, Hongji; Liu, Hongzhong; Liu, Xiaokang; Peng, Kai; Yu, Zhicheng

    2018-05-01

    The present work proposes a novel capacitive absolute positioning sensor based on time grating. The sensor includes a fine incremental-displacement measurement component combined with a coarse absolute-position measurement component to obtain high-resolution absolute positioning measurements. A single row type sensor was proposed to achieve fine displacement measurement, which combines the two electrode rows of a previously proposed double-row type capacitive displacement sensor based on time grating into a single row. To achieve absolute positioning measurement, the coarse measurement component is designed as a single-row type displacement sensor employing a single spatial period over the entire measurement range. In addition, this component employs a rectangular induction electrode and four groups of orthogonal discrete excitation electrodes with half-sinusoidal envelope shapes, which were formed by alternately extending the rectangular electrodes of the fine measurement component. The fine and coarse measurement components are tightly integrated to form a compact absolute positioning sensor. A prototype sensor was manufactured using printed circuit board technology for testing and optimization of the design in conjunction with simulations. Experimental results show that the prototype sensor achieves a ±300 nm measurement accuracy with a 1 nm resolution over a displacement range of 200 mm when employing error compensation. The proposed sensor is an excellent alternative to presently available long-range absolute nanometrology sensors owing to its low cost, simple structure, and ease of manufacturing.

  9. Emittance growth rates for displaced beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1993-05-01

    Emittance growth rates have been previously analyzed for nonuniform beams in linear channels and for initially uniform mismatched beams in nonlinear channels. These studies were for centered beams. Additional emittance growth can arise in cases where the beam is initially displaced. The purpose of this study is to obtain growth rates for displaced beams. This work differs from studies involving random displacement of electrodes. Our analysis assumes instead that the focusing system is perfectly aligned but that the beam is initially displaced with respect to the equilibrium axis. If the focusing force is slightly nonlinear, we find a gradual transfer of the potential energy of beam displacement into kinetic energy associated with emittance growth. We present explicit results for the emittance growth distance as a function of the nonlinearity of the channel. These results will have practical importance for designers of accelerators and transport systems when setting realistic tolerances for initial beam alignment. These tolerances will depend on the nonlinearity and the length of the system

  10. Is Fibular Fracture Displacement Consistent with Tibiotalar Displacement?

    NARCIS (Netherlands)

    van den Bekerom, Michel P. J.; van Dijk, C. Niek

    2010-01-01

    We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle

  11. Phenomenon of displacement in Arabic language

    Directory of Open Access Journals (Sweden)

    2015-09-01

    Full Text Available Displacement is one of the characteristics of language and common phenomena in the Arabic language. Not only is this phenomenon limited to Arabic poetry and prose, but it is also broadened, so we can see examples of this in the Qur'an. Because of this phenomenon extensively in Arabic literature and also because of its essence that leads to the transmission of the elements for the first visibility to the other visibility in the sentence and sometimes had to change the grammatical role of the words, its identify helps us in a better understanding of text and the correct translation of it and protects the reader from mistakes. This paper in the descriptive analytical approach tries studying of the phenomenon of the displacement in the Arabic language and bringing its instances in Arabic poetry and prose as well as verses contained in the Holy Quran, to show that through the types and characteristics in the Arabic language and to response to several questions, including: how important is the displacement and what is its types in rhetoric, and the reasons of the displacement, and etc... Of the most important results of this study may refer to the undeniable role of the displacement as a rhetorical method to better understanding of the texts including: one of the most important reasons of the displacement in the use of language is to improve speech verbally and morally, and violation of the standard language and create a poetic atmosphere, and the recognition of the occurrence of the phenomenon of displacement in the Arabic language that uphold different interpretations remote and estimates when faced with the displacement in the text and help us to understand it and etc...

  12. Earthquake related displacement fields near underground facilities

    International Nuclear Information System (INIS)

    Pratt, H.R.; Zandt, G.; Bouchon, M.

    1979-04-01

    Relative displacements of rock masses are evaluated in terms of geological evidence, seismological evidence, data from simulation experiments, and analytical predictive models. Numerical models have been developed to determine displacement fields as a function of depth, distance, and azimuth from an earthquake source. Computer calculations for several types of faults indicate that displacements decrease rapidly with distance from the fault, but that displacements can either increase or decrease as a function of depth depending on the type and geometry of the fault. For long shallow vertical strike-slip faults the displacement decreases markedly with depth. For square strike slip faults and for dip slip faults displacement does not decrease as markedly with depth. Geologic structure, material properties, and depth affect the seismic source spectrum. Amplification of the high frequencies of shear waves is larger by a factor of about 2 for layered geologic models than for an elastic half space

  13. Laser measurement of the LumiCal detector displacement

    International Nuclear Information System (INIS)

    Blocki, J.; Daniluk, W.; Gil, M.; Karbowiak, M.; Moszczynski, A.; Oliwa, K.; Pawlik, B.; Wierba, W.; Zawiejski, L.; Slominski, W.; Suszycki, L.

    2006-12-01

    The silicon-tungsten calorimeter LumiCal, located in very forward region of the future detector at the International Linear Collider, is proposed for precisely luminosity measurement. One of the requirements to fulfil this task is available information on the actual position of the calorimeter relative to the beam interaction area which should be known with accuracy of a few micrometers. In this paper we discuss the possible solutions for the positioning of the LumiCal electron detector by optical method. The results of the displacement measurement using a laser beam and a CCD camera are described. The measurements were performed on a proof-of-principle basis and achieved the accuracy of about ± 1 μm in x, y and ± μm in z direction. (author)

  14. Design and Preliminary Results of a Feedback Circuit for Plasma Displacement Control in IR-T1 Tokamak

    International Nuclear Information System (INIS)

    TalebiTaher, A.; Ghoranneviss, M.; Tarkeshian, R.; Salem, M. K.; Khorshid, P.

    2008-01-01

    Since displacement is very important for plasma position control, in IR-T1 tokamak a combination of two cosine coils and two saddle sine coils is used for horizontal displacement measurement. According to the multiple moment theory, the output of these coils linearly depends to radial displacement of plasma column. A new circuit for adding these signals to feedback system designed and unwanted effects of other fields in final output compensated. After compensation and calibration of the system, the output of horizontal displacement circuits applied to feedback control system. By considers the required auxiliary vertical field, a proportional amplifier and driver circuit are constructed to drive power transistors these power transistors switch the feedback bank capacitors. In the experiment, a good linear proportionality between displacement and output observed by applying an appropriate feedback field, the linger confinement time in IR-T1 tokamak obtained, applying this system to discharge increased the plasma duration and realizes repetitive discharges

  15. Mortality displacement as a function of heat event strength in 7 US cities.

    Science.gov (United States)

    Saha, Michael V; Davis, Robert E; Hondula, David M

    2014-02-15

    Mortality rates increase immediately after periods of high air temperature. In the days and weeks after heat events, time series may exhibit mortality displacement-periods of lower than expected mortality. We examined all-cause mortality and meteorological data from 1980 to 2009 in the cities of Atlanta, Georgia; Boston, Massachusetts; Minneapolis-St. Paul, Minnesota; Philadelphia, Pennsylvania; Phoenix, Arizona; Seattle, Washington; and St. Louis, Missouri. We modeled baseline mortality using a generalized additive model. Heat waves were defined as periods of 3 or more consecutive days in which the apparent temperature exceeded a variable percentile. For each heat wave, we calculated the sum of excess and deficit mortality. Mortality displacement, which is the ratio of grand sum deficit to grand sum excess mortality, decreased as a function of event strength in all cities. Displacement was close to 1.00 for the weakest events. At the highest temperatures, displacement varied from 0.35 (95% confidence interval: 0.21, 0.55) to 0.75 (95% confidence interval: 0.54, 0.97). We found strong evidence of acclimatization across cities. Without consideration of displacement effects, the net impacts of heat-wave mortality are likely to be significant overestimations. A statistically significant positive relationship between the onset temperature of nondisplaced heat mortality and mean warm-season temperature (R(2) = 0.78, P < 0.01) suggests that heat mortality thresholds may be predictable across cities.

  16. SOCIAL CAPITAL IN INVOLUNTARY DISPLACEMENT AND RESETTLEMENT

    Directory of Open Access Journals (Sweden)

    Melissa Quetulio-Navarra

    2013-07-01

    Full Text Available Social capital is often seen as a substitute for lack of other types of capital amongpoor people. Because of the recognized applicability of the social capital conceptand its correlation with the different dimensions of poverty, it has been used inevaluating the adaptation and integration of involuntarily displaced individualsinto their new environment. This paper presents insights based on a review of thefindings of studies that looked into the role of social capital in conflict- anddevelopment-induced displacement contexts. Althoughboth types of displace-ments are involuntary or forced in nature, they differ in terms of the role of socialcapital regarding its main sources, the formation pattern and its determinants.Social capital studies in forced resettlement appear to be relatively small innumber and are heavily concentrated on first worldcountries and conflict- anddevelopment-induced displacements. The conduct of similar studies in developingcountries and in a disaster-induced resettlement context, the third type ofinvoluntary displacement, should generate new and relevant findings regardingthe role of social capital in resettlement communities.

  17. Fundamental principles of rotary displacement meters

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, J. [Schlumberger Industries, Owenton, KY (United States)

    1995-12-01

    The gas meter exists to continually and accurately measure the volume of gas supplied over the complete flow range of the load. In effect the gas meter serves as the {open_quotes}cash register{close_quotes} of the gas industry; its accurate and dependable performance ensures fair dealings for both the supplier and the user. An investment both in and of itself, the gas meter should be chosen as a function of its usefullness both over the short term and the long term. Thus in addition to initial cost, one must take into account various associated factors, costs and benefits, including the following: Design Characteristics Application, suitability, Meter features and options, Operation constraints, Installation, Service and maintenance, Repair and replacement, Life expectancy, Compatibility with complimentary products, Correcting devices, Remote reading capabilities, Data generation and gathering, Upgradeabilty. This paper will look at one positive displacement meter, the Rotary meter, and address the fundamentals principals of the technology as well as looking at some of the benefits derived from its application. Rotary positive displacement meters were introduced at the end of last century. Used primarily for metering transmission sized loads, the meters` measuring capabilities have extended to cover nearly all areas of distribution with exception of domestic applications. Rotary meters are available in rated capacities from 800 cfh to 102,000 cfh and operating pressures from 175 PSIG to 1440 PSIG. The use of rotary meters on load ranges in the 800 to 10,000 cfh category has increased and is replacing the use of diaphragm meters because of the smaller relative size of rotaries, and improvements in rangeabilities in the last few years. Turbine meters are usually the meter of choice on loads over 16,000 cfh unless a meter with high rangeability is required because of varying load characteristics, in which case a large foot mounted rotary might still be selected.

  18. War, forced displacement and growth in Laotian adults.

    Science.gov (United States)

    Clarkin, Patrick F

    2012-01-01

    Evidence from several populations suggests that war negatively impacts civilian nutrition, physical growth and overall health. This effect is often enduring or permanent, particularly if experienced early in life. To assess whether the number of lifetime displacement experiences and being displaced in infancy were associated with adult height, sitting height, leg length and the sitting height ratio. Retrospective questionnaires on displacement and resettlement experiences and anthropometric data were collected from a sample of Laotian adult refugees (ethnic Hmong and Lao; n = 365). All were born in Laos or Thailand and had resettled in French Guiana or the US. Many had been displaced several times by military conflict in Laos. In bivariate analyses, being displaced in infancy and the number of lifetime displacement experiences one had were negatively associated with final adult height and leg length in both sexes. The association was stronger in females, particularly Hmong females. There was no significant association between total displacement experiences and the sitting height ratio. In multiple regression analyses, linear growth in males was negatively associated with being displaced in infancy; in females, the number of lifetime displacement experiences was a significant predictor. Forced displacement from war appears to have a lasting effect on final adult height, sitting height and leg length, although not necessarily on the sitting height ratio in this sample.

  19. Criteria for design of the Yucca Mountain structures, systems and components for fault displacement

    International Nuclear Information System (INIS)

    Stepp, C.; Hossain, Q.; Nesbit, S.; Pezzopane, S.; Hardy, M.

    1995-01-01

    The DOE intends to design the Yucca Mountain high-level waste facility structures, systems and components (SSCs) for fault displacements to provide reasonable assurance that they will meet the preclosure safety performance objectives established by 10 CFR Part 60. To the extent achievable, fault displacement design of the facility will follow guidance provided in the NRC Staff Technical Position. Fault avoidance will be the primary design criterion, especially for spatially compact or clustered SSCs. When fault avoidance is not reasonably achievable, expected to be the case for most spatially extended SSCs, engineering design procedures and criteria or repair and rehabilitation actions, depending on the SSC's importance to safety, are provided. SSCs that have radiological safety importance will be designed for fault displacements that correspond to the hazard exceedance frequency equal to their established seismic safety performance goals. Fault displacement loads are generally localized and may cause local inelastic response of SSCs. For this reason, the DOE intends to use strain-based design acceptance criteria similar to the strain-based criteria used to design nuclear plant SSCs for impact and impulsive loads

  20. Displacement Ventilation

    DEFF Research Database (Denmark)

    Bjørn, Erik; Mattsson, Magnus; Sandberg, Mats

    Full-scale experiments were made in a displacement ventilated room with two breathing thermal manikins to study the effect of movements and breathing on the vertical contaminant distribution, and on the personal exposure of occupants. Concentrations were measured with tracer gas equipment...

  1. Nonimaging speckle interferometry for high-speed nanometer-scale position detection.

    Science.gov (United States)

    van Putten, E G; Lagendijk, A; Mosk, A P

    2012-03-15

    We experimentally demonstrate a nonimaging approach to displacement measurement for complex scattering materials. By spatially controlling the wavefront of the light that incidents on the material, we concentrate the scattered light in a focus on a designated position. This wavefront acts as a unique optical fingerprint that enables precise position detection of the illuminated material by simply measuring the intensity in the focus. By combining two fingerprints we demonstrate position detection along one in-plane dimension with a displacement resolution of 2.1 nm. As our approach does not require an image of the scattered field, it is possible to employ fast nonimaging detectors to enable high-speed position detection of scattering materials.

  2. Tracking speckle displacement by double Kalman filtering

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ A tracking technique using two sequentially-connected Kalman filter for tracking laser speckle displacement is presented. One Kalman filter tracks temporal speckle displacement, while another Kalman filter tracks spatial speckle displacement. The temporal Kalman filter provides a prior for the spatial Kalman filter, and the spatial Kalman filter provides measurements for the temporal Kalman filter. The contribution of a prior to estimations of the spatial Kalman filter is analyzed. An optical analysis system was set up to verify the double-Kalman-filter tracker's ability of tracking laser speckle's constant displacement.

  3. Displaced epithelium after liposuction for gynecomastia.

    Science.gov (United States)

    McLaughlin, Cristina S; Petrey, Chris; Grant, Shawn; Ransdell, Jill S; Reynolds, Carol

    2011-08-01

    The authors describe the case of a 36-year-old man with gynecomastia who was previously treated with liposuction of the breast for cosmetic purposes. Histologic examination of a subsequent excisional biopsy revealed nests of displaced epithelial cells in adipose tissue. Epithelial cell displacement is a well-known risk of core needle biopsies and fine-needle aspirations of breast lesions. However, to the authors' knowledge, epithelial displacement in gynecomastia after liposuction, mimicking invasive ductal carcinoma, has not previously been reported.

  4. Emerging organic pollutants in the vadose zone of a soil aquifer treatment system: Pore water extraction using positive displacement.

    Science.gov (United States)

    Sopilniak, Alexander; Elkayam, Roy; Rossin, Anna Voloshenko; Lev, Ovadia

    2018-01-01

    Trace organic compounds in effluents, water streams and aquifers are amply reported. However, the mobile pool of Emerging Organic Contaminants (EOCs) in the deep parts of the vadose zone is hard to estimate, due to difficulties in extraction of sufficient quantity of pore water. Here, we present a new methodology for depth profiling of EOCs in pore water by Positive Displacement Extraction (PDE): Pore water extraction from unsaturated soil samples is carried out by withdrawal of soil cores by direct-push drilling and infiltrating the core by organics free water. We show that EOC concentrations in the water eluted in the plateau region of the inverse breakthrough curve is equal to their pore water concentrations. The method was previously validated for DOC extraction, and here the scope of the methodology is extended to pore water extraction for organic pollutants analysis. Method characteristics and validation were carried out with atrazine, simazine, carbamazepine, venlafaxine, O-desmethylvenlafaxine and caffeine in the concentration range of several ng to several μg/liter. Validation was carried out by laboratory experiments on three different soils (sandy, sandy-clayey and clayey). Field studies in the vadose zone of a SAT system provided 27 m deep EOC profiles with less than 1.5 m spatial resolution. During the percolation treatment, carbamazepine remained persistent, while the other studied EOCs were attenuated to the extent of 50-99%.The highest degradation rate of all studied EOCs was in the aerobic zone. EOC levels based on PDE and extraction by centrifugation were compared, showing a positive bias for centrifugation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Surgical treatment on displaced and dislocated sagittal fractures of the mandibular condyle.

    Science.gov (United States)

    Jing, Jie; Han, Yu; Song, Yu; Wan, Yingbiao

    2011-06-01

    The purpose of this study was to evaluate the effect of surgical treatment on displaced and dislocated sagittal fractures of the mandibular condyle (SFMC). Twenty-four patients with 28 displaced and dislocated SFMCs were distinguished into type M, type C, and type L fractures according the location of the fracture line. The fractured fragment was reduced and fixated with two 0.6-mm 4-hole micro-plates via a preauricular temporal incision. The fragment was extirpated when it was too small to be fixated. The postoperative position and profile of the fragment was examined by orthopantomogram radiograph or computed tomography (CT). The function of the temporal and zygomatic branches of the facial nerve was inspected. The occluding relation was surveyed, the interincisal distance at maximum mouth opening was measured, and the deviation from the midline during mouth opening was recorded. Twenty-three condyles (82%) suffered dislocated fractures with the condylar fragment out of the glenoid fossa. Five condyles (18%) were displaced, but not dislocated. There were 2 (7%) type M, 19 (68%) type C (3 comminuted), and 7 (25%) type L fractures (1 comminuted), respectively. Twenty-one (75%) fractured fragments received free-graft procedures with 2 micro-plates. Four (14%) fragments were reduced and fixated without being dissected free of their attachments. Three (11%) fragments were extirpated. There were no permanent facial never branch injuries. Micro-plate removal was necessary because of postoperative infection and necrosis of the fractured fragment in 1 condylar process. No other patients could be found with obvious postoperative bone resorption. The average postoperative maximum mouth opening and deviation at 6 months were improved significantly. The postoperative occlusion was good in 22 cases. Access with the preauricular incision, and the dislocated and displaced fragment can be reduced and fixated to its normal position easily. Free-graft procedure is a suitable

  6. Finding the displacement of wood structure in heritage building by 3D laser scanner

    Science.gov (United States)

    Lee, M. C.; Tsai, Y. L.; Wang, R. Z.; Lin, M. L.

    2015-08-01

    Heritage buildings are highly prone to long term damage from the microclimate, scourge and vandalism, which can result in damaged materials, structures, painting and cultural heritage items. This study will focus on finding the displacement of wood structural members through the use of a 3D laser scanner and the 4D concept of time. The results will compare the scans from different periods to find the difference (if any) in the structural member position. Wood structures usually consist of numerous wood members connected to form the structure. However, these members can be damaged in various ways such as physical mechanisms, chemical reactions, and biological corrosion. When damage to the wood structure occurs, the structural displacement can be affected, and if affected severely, can lead to a building collapse. Monitoring of the structural displacement is the best way to discover damage immediately and to preserve the heritage building. However, the Cultural Heritage Preservation Law in Taiwan prohibits the installation of monitoring instruments (e.g strain gauge, accelerometer) in historic structures (heritage buildings). Scanning the wood structure with 3D lasers is the most non-intrusive method and quickly achieves displacement through visualization. The displacement scan results can be compared with different periods and different members to analyze the severity of damage. Once the 3D scanner is installed, the whole building is scanned, and point clouds created to build the visual building model. The structural displacement can be checked via the building model and the differences are measured between each member to find the high risk damaged areas or members with large displacement. Early detection of structural damage is the most effective way means of preservation.

  7. Transient digitizer with displacement current samplers

    Science.gov (United States)

    McEwan, Thomas E.

    1996-01-01

    A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board.

  8. Prolonged displacement may compromise resilience in Eritrean mothers.

    Science.gov (United States)

    Almedom, Astier; Tesfamichael, Berhe; Mohammed, Zein; Mascie-Taylor, Nick; Muller, Jocelyn; Alemu, Zemui

    2005-12-01

    to assess the impact of prolonged displacement on the resilience of Eritrean mothers. an adapted SOC scale (short form) was administered. Complementary qualitative data were gathered from study participants' spontaneous reactions to and commentaries on the SOC scale. Displaced women's SOC scores were significantly less than those of the non-displaced: Mean = 54.84; SD = 6.48 in internally displaced person (IDP) camps, compared to non-displaced urban and rural/pastoralist: Mean = 48. 94, SD = 11.99; t = 3.831, p urban (non-displaced). Rural but traditionally mobile (pastoralist or transhumant) communities scored more or less the same as the urban non-displaced--i.e., significantly higher than those in IDP camps (p urban and pastoralist/transhumant groups were similar, while women in IDP camps were lower scoring--RR = .268, p < .001. The implications of these findings for health policy are critical. It is incumbent on the international health institutions including the World Health Organization and regional as well as local players to address the plight of internally displaced women, their families and communities in Eritrea and other places of dire conditions such as, for example Darfur in the Sudan.

  9. Vibration-Driven Microrobot Positioning Methodologies for Nonholonomic Constraint Compensation

    Directory of Open Access Journals (Sweden)

    Kostas Vlachos

    2015-03-01

    Full Text Available This paper presents the formulation and practical implementation of positioning methodologies that compensate for the nonholonomic constraints of a mobile microrobot that is driven by two vibrating direct current (DC micromotors. The open-loop and closed-loop approaches described here add the capability for net sidewise displacements of the microrobotic platform. A displacement is achieved by the execution of a number of repeating steps that depend on the desired displacement, the speed of the micromotors, and the elapsed time. Simulation and experimental results verified the performance of the proposed methodologies.

  10. Force-displacement measurements of earlywood bordered pits using a mesomechanical tester.

    Science.gov (United States)

    Zelinka, Samuel L; Bourne, Keith J; Hermanson, John C; Glass, Samuel V; Costa, Adriana; Wiedenhoeft, Alex C

    2015-10-01

    The elastic properties of pit membranes are reported to have important implications in understanding air-seeding phenomena in gymnosperms, and pit aspiration plays a large role in wood technological applications such as wood drying and preservative treatment. Here we present force-displacement measurements for pit membranes of circular bordered pits, collected on a mesomechanical testing system. The system consists of a quartz microprobe attached to a microforce sensor that is positioned and advanced with a micromanipulator mounted on an inverted microscope. Membrane displacement is measured from digital image analysis. Unaspirated pits from earlywood of never-dried wood of Larix and Pinus and aspirated pits from earlywood of dried wood of Larix were tested to generate force-displacement curves up to the point of membrane failure. Two failure modes were observed: rupture or tearing of the pit membrane by the microprobe tip, and the stretching of the pit membrane until the torus was forced out of the pit chamber through the pit aperture without rupture, a condition we refer to as torus prolapse. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  11. Effects of alveolar bone displacement with segmental osteotomy: micro-CT and histomorphometric analysis in rats

    Directory of Open Access Journals (Sweden)

    Taegun KIM

    Full Text Available Abstract The purpose of this study was to evaluate the effects of segmental osteotomy on the blood vessels and osteoclasts in rats using micro-computed tomography (micro-CT and histomorphometric analysis. After segmental osteotomy was performed around the maxillary first molars of 36 male Sprague-Dawley rats (n = 72, the samples were divided into a control group (no displacement, 0.5 D group (0.5 mm buccal displacement and 1.0 D group (1.0 mm buccal displacement (n = 24/group. At 1, 2, 4 and 8 weeks after surgery, changes in the blood vessel volume were investigated using micro-CT with perfusion of radiopaque silicone rubber. Tartrate-resistant acid phosphatase (TRAP staining was used for histomorphometric analysis. Two-way repeated measures analysis of variance (rmANOVA was performed to compare the volume of blood vessels and number of TRAP-positive osteoclasts among the groups. Regarding blood vessel volume, the displacement groups had no significant effects, while the time points had significant effects (p = 0.014. The blood vessel volume at 1 week was significantly smaller than that at 2, 4, and 8 weeks (p = 0.004, p = 0.026, and p = 0.005, respectively. Regarding TRAP cell count, the displacement groups had no significant effects, while the time points had significant effects (p < 0.001. The number of TRAP-positive osteoclasts at 8 weeks was significantly smaller than that at 1, 2, and 4 weeks (p < 0.001, p < 0.001, and p = 0.002, respectively, and the count at 4 weeks was smaller than that at 1 week (p = 0.011. Therefore, a regional osteoclast-related acceleratory phenomenon was maintained until 4 weeks after surgery.

  12. Displacement of the abomasum in dairy cows: risk factors and pre-clinical alterations

    NARCIS (Netherlands)

    Winden, Stefanus Cornelis Leonardus van

    2002-01-01

    Displacement of the abomasum (DA) in dairy cows is a disorder described since the fifties of the previous century. Since then, a considerable amount of research concerning DA is conducted. The normal, healthy abomasum is positioned in the ventral part of the abdominal cavity. As a result of

  13. Displaced and non-displaced Colombian children's evaluations of moral transgressions, retaliation, and reconciliation

    Science.gov (United States)

    Ardila-Rey, Alicia; Killen, Melanie; Brenick, Alaina

    2015-01-01

    In order to assess the effects of displacement and exposure to violence on children's moral reasoning, Colombian children exposed to minimal violence (non-displaced or low-risk) (N = 99) and to extreme violence (displaced or high-risk) (N = 94), evenly divided by gender, at 6-, 9-, and 12 - years of age, were interviewed regarding their evaluation of peer-oriented moral transgressions (hitting and not sharing toys). The vast majority of children evaluated moral transgressions as wrong. Group and age differences were revealed, however, regarding provocation and retaliation. Children who were exposed to violence, in contrast to those with minimum exposure, judged it more legitimate to inflict harm or deny resources when provoked and judged it more okay to retaliate for reasons of retribution. Surprisingly, and somewhat hopefully, all children viewed reconciliation as feasible. The results are informative regarding theories of morality, culture, and the effects of violence on children's social development. PMID:25722543

  14. EFFECT OF THINNING AND FERTILIZATION ON Eucalyptus grandis Hill ex-Maiden PITH DISPLACEMENT AND LOG END SPLITTlNG

    Directory of Open Access Journals (Sweden)

    Israel Luiz de Lima

    2007-06-01

    Full Text Available The aim of this study was to analyse the influence of thinning and fertilization on some log properties which influence sawn wood yield in a 21 year-old grown Eucalyptus grandis stand. Three selective thinning intensities (37, 50 and 75%, presence or absence of fertilizers on the beginning of the thinning, two diameter classes and two logs taken from two different vertical positions were taken as the study factors. The influence of the factors and their combination on tree growth stresses were indirectly evaluate through log end splitting and pith displacement in relation to its normal central position. Thinning, fertilization, diameter class and log position on the tree height did not have significant effect on pith displacement. The logs from fertilized plots presented higher log end splitting index than others.

  15. Displacement of location in illusory line motion.

    Science.gov (United States)

    Hubbard, Timothy L; Ruppel, Susan E

    2013-05-01

    Six experiments examined displacement in memory for the location of the line in illusory line motion (ILM; appearance or disappearance of a stationary cue is followed by appearance of a stationary line that is presented all at once, but the stationary line is perceived to "unfold" or "be drawn" from the end closest to the cue to the end most distant from the cue). If ILM was induced by having a single cue appear, then memory for the location of the line was displaced toward the cue, and displacement was larger if the line was closer to the cue. If ILM was induced by having one of two previously visible cues vanish, then memory for the location of the line was displaced away from the cue that vanished. In general, the magnitude of displacement increased and then decreased as retention interval increased from 50 to 250 ms and from 250 to 450 ms, respectively. Displacement of the line (a) is consistent with a combination of a spatial averaging of the locations of the cue and the line with a relatively weaker dynamic in the direction of illusory motion, (b) might be implemented in a spreading activation network similar to networks previously suggested to implement displacement resulting from implied or apparent motion, and (c) provides constraints and challenges for theories of ILM.

  16. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  17. Variable displacement alpha-type Stirling engine

    Science.gov (United States)

    Homutescu, V. M.; Bălănescu, D. T.; Panaite, C. E.; Atanasiu, M. V.

    2016-08-01

    The basic design and construction of an alpha-type Stirling engine with on load variable displacement is presented. The variable displacement is obtained through a planar quadrilateral linkage with one on load movable ground link. The physico-mathematical model used for analyzing the variable displacement alpha-type Stirling engine behavior is an isothermal model that takes into account the real movement of the pistons. Performances and power adjustment capabilities of such alpha-type Stirling engine are calculated and analyzed. An exemplification through the use of the numerical simulation was performed in this regard.

  18. Pathways linking war and displacement to parenting and child adjustment: A qualitative study with Syrian refugees in Lebanon.

    Science.gov (United States)

    Sim, Amanda; Fazel, Mina; Bowes, Lucy; Gardner, Frances

    2018-03-01

    Forcibly displaced children are at risk of a range of negative outcomes, yet little is known about how to support war-affected caregivers in promoting children's psychosocial resilience. The current study uses qualitative methods to examine the mechanisms underlying the effects of war and displacement on parenting and child adjustment in order to inform intervention development. In April and November 2016, group and individual interviews were conducted with 39 Syrian parents and 15 children in partnership with a humanitarian organization in Lebanon. Interviews were transcribed and analyzed using a grounded theory approach. Results show three interrelated pathways linking daily displacement stressors to various dimensions of parenting: (1) economic hardship prevents parents from meeting their children's basic needs and forces adaptation strategies that impair positive parent-child interactions; (2) parental psychological distress contributes to harsh parenting; and (3) perceptions and experiences of insecurity in the community results in increased parental control. Greater economic resources and social support emerged as potential protective factors for maintaining positive parenting despite exposure to war and displacement-related adversity. Our findings suggest that implementation of policies and programs to remove structural barriers to refugees' physical and economic security can have tangible impacts on parental mental health, parenting quality, and child psychosocial outcomes. Future research priorities include a stronger focus on the effects of war and displacement on family processes, taking into account interactions with the broader social, economic and political context. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Evaluation of Stiffness Changes in a High-Rise Building by Measurements of Lateral Displacements Using GPS Technology

    Science.gov (United States)

    Choi, Se Woon; Kim, Ill Soo; Park, Jae Hwan; Kim, Yousok; Sohn, Hong Gyoo; Park, Hyo Seon

    2013-01-01

    The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS). To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements. PMID:24233025

  20. Evaluation of Stiffness Changes in a High-Rise Building by Measurements of Lateral Displacements Using GPS Technology

    Directory of Open Access Journals (Sweden)

    Se Woon Choi

    2013-11-01

    Full Text Available The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS. To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements.

  1. Neutron displacement damage cross sections for SiC

    International Nuclear Information System (INIS)

    Huang Hanchen; Ghoniem, N.

    1993-01-01

    Calculations of neutron displacement damage cross sections for SiC are presented. We use Biersack and Haggmark's empirical formula in constructing the electronic stopping power, which combines Lindhard's model at low PKA energies and Bethe-Bloch's model at high PKA energies. The electronic stopping power for polyatomic materials is computed on the basis of Bragg's Additivity Rule. A continuous form of the inverse power law potential is used for nuclear scattering. Coupled integro-differential equations for the number of displaced atoms j, caused by PKA i, are then derived. The procedure outlined above gives partial displacement cross sections, displacement cross sections for each specie of the lattice, and for each PKA type. The corresponding damage rates for several fusion and fission neutron spectra are calculated. The stoichiometry of the irradiated material is investigated by finding the ratio of displacements among various atomic species. The role of each specie in displacing atoms is also investigated by calculating the fraction of displacements caused by each PKA type. The study shows that neutron displacement damage rates of SiC in typical magnetic fusion reactor first walls will be ∝10-15 dpa MW -1 m 2 ; in typical lead-protected inertial confinement fusion reactor first walls they will be ∝15-20 dpa MW -1 m 2 . For fission spectra, we find that the neutron displacement damage rate of SiC is ∝74 dpa per 10 27 n/m 2 in FFTF, ∝39 dpa per 10 27 n/m 2 in HFIR, and 25 dpa per 10 27 n/m 2 in NRU. Approximately 80% of displacement atoms are shown to be of the carbon-type. (orig.)

  2. Asymmetric SOL Current in Vertically Displaced Plasma

    Science.gov (United States)

    Cabrera, J. D.; Navratil, G. A.; Hanson, J. M.

    2017-10-01

    Experiments at the DIII-D tokamak demonstrate a non-monotonic relationship between measured scrape-off layer (SOL) currents and vertical displacement event (VDE) rates with SOL currents becoming largely n=1 dominant as plasma is displaced by the plasma control system (PCS) at faster rates. The DIII-D PCS is used to displace the magnetic axis 10x slower than the intrinsic growth time of similar instabilities in lower single-null plasmas. Low order (n VDE instabilities observed when vertical control is disabled. Previous inquiry shows VDE asymmetry characterized by SOL current fraction and geometric parameters of tokamak plasmas. We note that, of plasmas displaced by the PCS, short displacement time scales near the limit of the PCS temporal control appear to result in larger n=1/n=2 asymmetries. Work supported under USDOE Cooperative Agreement DE-FC02-04ER54698 and DE-FG02-04ER54761.

  3. Lack of Correlation Between External Fiducial Positions and Internal Tumor Positions During Breath-Hold CT

    International Nuclear Information System (INIS)

    Hunjan, Sandeep; Starkschall, George; Prado, Karl; Dong Lei; Balter, Peter

    2010-01-01

    Purpose: For thoracic tumors, if four-dimensional computed tomography (4DCT) is unavailable, the internal margin can be estimated by use of breath-hold (BH) CT scans acquired at end inspiration (EI) and end expiration (EE). By use of external surrogates for tumor position, BH accuracy is estimated by minimizing the difference between respiratory extrema BH and mean equivalent-phase free breathing (FB) positions. We tested the assumption that an external surrogate for BH accuracy correlates with internal tumor positional accuracy during BH CT. Methods and Materials: In 16 lung cancer patients, 4DCT images, as well as BH CT images at EI and EE, were acquired. Absolute differences between BH and mean equivalent-phase (FB) positions were calculated for both external fiducials and gross tumor volume (GTV) centroids as metrics of external and internal BH accuracy, respectively, and the results were correlated. Results: At EI, the absolute difference between mean FB and BH fiducial displacement correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.11). Similarly, at EE, the absolute difference between mean FB and BH fiducial displacements correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.18). Conclusions: External surrogates for tumor position are not an accurate metric of BH accuracy for lung cancer patients. This implies that care should be taken when using such an approach because an incorrect internal margin could be generated.

  4. Force transmissibility versus displacement transmissibility

    Science.gov (United States)

    Lage, Y. E.; Neves, M. M.; Maia, N. M. M.; Tcherniak, D.

    2014-10-01

    It is well-known that when a single-degree-of-freedom (sdof) system is excited by a continuous motion of the foundation, the force transmissibility, relating the force transmitted to the foundation to the applied force, equals the displacement transmissibility. Recent developments in the generalization of the transmissibility to multiple-degree-of-freedom (mdof) systems have shown that similar simple and direct relations between both types of transmissibility do not appear naturally from the definitions, as happens in the sdof case. In this paper, the authors present their studies on the conditions under which it is possible to establish a relation between force transmissibility and displacement transmissibility for mdof systems. As far as the authors are aware, such a relation is not currently found in the literature, which is justified by being based on recent developments in the transmissibility concept for mdof systems. Indeed, it does not appear naturally, but the authors observed that the needed link is present when the displacement transmissibility is obtained between the same coordinates where the applied and reaction forces are considered in the force transmissibility case; this implies that the boundary conditions are not exactly the same and instead follow some rules. This work presents a formal derivation of the explicit relation between the force and displacement transmissibilities for mdof systems, and discusses its potential and limitations. The authors show that it is possible to obtain the displacement transmissibility from measured forces, and the force transmissibility from measured displacements, opening new perspectives, for example, in the identification of applied or transmitted forces. With this novel relation, it becomes possible, for example, to estimate the force transmissibility matrix with the structure off its supports, in free boundary conditions, and without measuring the forces. As far as force identification is concerned, this

  5. The Chinese Export Displacement Effect Revisited

    DEFF Research Database (Denmark)

    Elleby, Christian; Yu, Wusheng; Yu, Qian

    China’s global export share has increased dramatically over the past decades. This development has prompted an empirical literature on whether Chinese exports displace those originated from elsewhere in various destination markets. In this paper we focus on the growth of China’s exports to the East...... African Community (EAC) countries and show how it has affected exports from the European Union (EU) to the EAC. Our main contribution to the literature on the displacement effect of Chinese exports is a set of total and relative displacement estimates based on different specifications of the gravity model...... where we control for country-year fixed effects so as to avoid the “gold medal mistake” of not accounting for time varying “multilateral resistance”. Our findings do not support the hypothesis that Chinese exports have displaced exports from other countries in general. Nor do they support the hypothesis...

  6. The Three Gorges: the unexamined toll of development-induced displacement

    Directory of Open Access Journals (Sweden)

    Martin Stein

    1998-04-01

    Full Text Available In China, the context of forced displacement in its broadest sense centres on four issues: (1 coercive displacement for development; (2 political persecution resulting in controlled displacement; (3 massive labour dislocations; and (4 disaster-induced displacement. This article looks at the role of the state in displacement, focusing on the first of these issues: development-induced displacement.

  7. Impact of Audio-Coaching on the Position of Lung Tumors

    International Nuclear Information System (INIS)

    Haasbeek, Cornelis J.A.; Spoelstra, Femke; Lagerwaard, Frank J.; Soernsen de Koste, John R. van; Cuijpers, Johan P.; Slotman, Ben J.; Senan, Suresh

    2008-01-01

    Purpose: Respiration-induced organ motion is a major source of positional, or geometric, uncertainty in thoracic radiotherapy. Interventions to mitigate the impact of motion include audio-coached respiration-gated radiotherapy (RGRT). To assess the impact of coaching on average tumor position during gating, we analyzed four-dimensional computed tomography (4DCT) scans performed both with and without audio-coaching. Methods and Materials: Our RGRT protocol requires that an audio-coached 4DCT scan is performed when the initial free-breathing 4DCT indicates a potential benefit with gating. We retrospectively analyzed 22 such paired scans in patients with well-circumscribed tumors. Changes in lung volume and position of internal target volumes (ITV) generated in three consecutive respiratory phases at both end-inspiration and end-expiration were analyzed. Results: Audio-coaching increased end-inspiration lung volumes by a mean of 10.2% (range, -13% to +43%) when compared with free breathing (p = 0.001). The mean three-dimensional displacement of the center of ITV was 3.6 mm (SD, 2.5; range, 0.3-9.6mm), mainly caused by displacement in the craniocaudal direction. Displacement of ITV caused by coaching was more than 5 mm in 5 patients, all of whom were in the subgroup of 9 patients showing total tumor motion of 10 mm or more during both coached and uncoached breathing. Comparable ITV displacements were observed at end-expiration phases of the 4DCT. Conclusions: Differences in ITV position exceeding 5 mm between coached and uncoached 4DCT scans were detected in up to 56% of mobile tumors. Both end-inspiration and end-expiration RGRT were susceptible to displacements. This indicates that the method of audio-coaching should remain unchanged throughout the course of treatment

  8. Effect of structure variation of the aptamer-DNA duplex probe on the performance of displacement-based electrochemical aptamer sensors.

    Science.gov (United States)

    Pang, Jie; Zhang, Ziping; Jin, Haizhu

    2016-03-15

    Electrochemical aptamer-based (E-AB) sensors employing electrode-immobilized, redox-tagged aptamer probes have emerged as a promising platform for the sensitive and quick detection of target analytes ranging from small molecules to proteins. Signal generation in this class of sensor is linked to change in electron transfer efficiency upon binding-induced change in flexibility/conformation of the aptamer probe. Because of this signaling mechanism, signal gains of these sensors can be improved by employing a displacement-based recognition system, which links target binding with a large-scale flexibility/conformation shift from the aptamer-DNA duplex to the single-stranded DNA or the native aptamer. Despite the relatively large number of displacement-based E-AB sensor samples, little attention has been paid to the structure variation of the aptamer-DNA duplex probe. Here we detail the effects of complementary length and position of the aptamer-DNA duplex probe on the performance of a model displacement-based E-AB sensor for ATP. We find that, greater background suppression and signal gain are observed with longer complementary length of the aptamer-DNA duplex probe. However, sensor equilibration time slows monotonically with increasing complementary length; and with too many target binding sites in aptamer sequence being occupied by the complementary DNA, the aptamer-target binding does not occur and no signal gain observed. We also demonstrate that signal gain of the displacement-based E-AB sensor is strongly dependent on the complementary position of the aptamer-DNA duplex probe, with complementary position located at the electrode-attached or redox-tagged end of the duplex probe, larger background suppression and signal increase than that of the middle position are observed. These results highlight the importance of rational structure design of the aptamer-DNA duplex probe and provide new insights into the optimization of displacement-based E-AB sensors. Copyright

  9. Displaced Homemakers: Vo-Tech Workshop Guide.

    Science.gov (United States)

    Peltier, Wanda Jo

    Written for displaced homemaker programs in vocational-technical schools, this curriculum contains material designed so that instructors can prepare student manuals appropriate to almost any educational support situation for displaced homemakers. An overview provides information on special needs groups, curriculum use, and resources and sample…

  10. 5 CFR 330.706 - Notification of displaced employees.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Notification of displaced employees. 330... RECRUITMENT, SELECTION, AND PLACEMENT (GENERAL) Interagency Career Transition Assistance Plan for Displaced Employees § 330.706 Notification of displaced employees. (a) In addition to meeting the requirements of...

  11. Design and Testing of a Flexible Inclinometer Probe for Model Tests of Landslide Deep Displacement Measurement.

    Science.gov (United States)

    Zhang, Yongquan; Tang, Huiming; Li, Changdong; Lu, Guiying; Cai, Yi; Zhang, Junrong; Tan, Fulin

    2018-01-14

    The physical model test of landslides is important for studying landslide structural damage, and parameter measurement is key in this process. To meet the measurement requirements for deep displacement in landslide physical models, an automatic flexible inclinometer probe with good coupling and large deformation capacity was designed. The flexible inclinometer probe consists of several gravity acceleration sensing units that are protected and positioned by silicon encapsulation, all the units are connected to a 485-comunication bus. By sensing the two-axis tilt angle, the direction and magnitude of the displacement for a measurement unit can be calculated, then the overall displacement is accumulated according to all units, integrated from bottom to top in turn. In the conversion from angle to displacement, two spline interpolation methods are introduced to correct and resample the data; one is to interpolate the displacement after conversion, and the other is to interpolate the angle before conversion; compared with the result read from checkered paper, the latter is proved to have a better effect, with an additional condition that the displacement curve move up half the length of the unit. The flexible inclinometer is verified with respect to its principle and arrangement by a laboratory physical model test, and the test results are highly consistent with the actual deformation of the landslide model.

  12. 40 CFR 205.153 - Engine displacement.

    Science.gov (United States)

    2010-07-01

    ..., in accordance with American Society for Testing Materials (ASTM) E 29-67. (b) For rotary engines... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Engine displacement. 205.153 Section... TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycles § 205.153 Engine displacement. (a) Engine...

  13. Dissolved oxygen detection by galvanic displacement-induced

    Indian Academy of Sciences (India)

    Dissolved oxygen detection by galvanic displacement-induced graphene/silver nanocomposite ... dissolved oxygen (DO) detection based on a galvanic displacement synthesized reduced graphene oxide–silver nanoparticles ... Current Issue

  14. Three-Dimensional Displacement of Nine Different Abutments for an Implant with an Internal Hexagon Platform.

    Science.gov (United States)

    Gilbert, Andy B; Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin A; Clelland, Nancy L; Chien, Hua-Hong

    2015-01-01

    Clinicians need to know whether there are any differences among the many abutment options available for restoring a particular implant. This study aims to compare nine abutments for one implant system for positional changes between hand tightening and torqueing. Nine Tapered Screw-Vent (TSV) implants were placed into a resin block. Five specimens of nine different abutments (n = 45) were tried in one of the nine implants. Initially, the abutments were torqued to 20 Ncm to represent hand tightening. Abutments were tightened to 30 Ncm using a torque driver as recommended by the manufacturer for final seating. Images were recorded in 12-second intervals for approximately 10 minutes after the torque was applied. The spatial relationship of the abutments to the resin block was determined using three-dimensional digital image correlation. Commercial image correlation software was used to analyze the displacements. Mean displacements for the nine different abutments were calculated in all three dimensions and for overall displacement in space. A t test with a step-down Bonferroni correction was used for a pairwise comparison of each abutment's mean displacements to the other abutments to determine statistical differences (α = .05). The Atlantis titanium, Inclusive titanium, and Legacy zirconia abutments showed mean displacements that were statistically significantly higher than other abutments in the horizontal direction. The overall three-dimensional displacement of the Atlantis titanium abutment after an applied 30-Ncm torque was significantly higher than that of six of the other eight abutments (P displacement between hand tightening and torqueing than the Atlantis titanium or Inclusive titanium abutments when used to restore a TSV implant.

  15. Combination of optically measured coordinates and displacements for quantitative investigation of complex objects

    Science.gov (United States)

    Andrae, Peter; Beeck, Manfred-Andreas; Jueptner, Werner P. O.; Nadeborn, Werner; Osten, Wolfgang

    1996-09-01

    Holographic interferometry makes it possible to measure high precision displacement data in the range of the wavelength of the used laser light. However, the determination of 3D- displacement vectors of objects with complex surfaces requires the measurement of 3D-object coordinates not only to consider local sensitivities but to distinguish between in-plane deformation, i.e. strains, and out-of-plane components, i.e. shears, too. To this purpose both the surface displacement and coordinates have to be combined and it is advantageous to make the data available for CAE- systems. The object surface has to be approximated analytically from the measured point cloud to generate a surface mesh. The displacement vectors can be assigned to the nodes of this surface mesh for visualization of the deformation of the object under test. They also can be compared to the results of FEM-calculations or can be used as boundary conditions for further numerical investigations. Here the 3D-object coordinates are measured in a separate topometric set-up using a modified fringe projection technique to acquire absolute phase values and a sophisticated geometrical model to map these phase data onto coordinates precisely. The determination of 3D-displacement vectors requires the measurement of several interference phase distributions for at least three independent sensitivity directions depending on the observation and illumination directions as well as the 3D-position of each measuring point. These geometric quantities have to be transformed into a reference coordinate system of the interferometric set-up in order to calculate the geometric matrix. The necessary transformation can be realized by means of a detection of object features in both data sets and a subsequent determination of the external camera orientation. This paper presents a consistent solution for the measurement and combination of shape and displacement data including their transformation into simulation systems. The

  16. Psychiatric implications of displacement: contributions from the psychology of place.

    Science.gov (United States)

    Fullilove, M T

    1996-12-01

    The purpose of this article is to describe the psychological processes that are affected by geographic displacement. The literature from the fields of geography, psychology, anthropology, and psychiatry was reviewed to develop a "psychology of place" and to determine the manner in which place-related psychological processes are affected by upheaval in the environment. The psychology of place is an emerging area of research that explores the connection between individuals and their intimate environments. The psychology of place posits that individuals require a "good enough" environment in which to live. They are linked to that environment through three key psychological processes: attachment, familiarity, and identity. Place attachment, which parallels, but is distinct from, attachment to person, is a mutual caretaking bond between a person and a beloved place. Familiarity refers to the processes by which people develop detailed cognitive knowledge of their environs. Place identity is concerned with the extraction of a sense of self based on the places in which one passes one's life. Each of these psychological processes-attachment, familiarity, and place identity-is threatened by displacement, and the problems of nostalgia, disorientation, and alienation may ensue. As a result of war, decolonization, epidemics, natural disasters, and other disruptive events, millions of people are currently displaced from their homes. Protecting and restoring their mental health pose urgent problems for the mental health community.

  17. Static Analysis of High-Performance Fixed Fluid Power Drive with a Single Positive-Displacement Hydraulic Motor

    Directory of Open Access Journals (Sweden)

    O. F. Nikitin

    2015-01-01

    Full Text Available The article deals with the static calculations in designing a high-performance fixed fluid power drive with a single positive-displacement hydraulic motor. Designing is aimed at using a drive that is under development and yet unavailable to find and record the minimum of calculations and maximum of existing hydraulic units that enable clear and unambiguous performance, taking into consideration an available assortment of hydraulic units of hydraulic drives, to have the best efficiency.The specified power (power, moment and kinematics (linear velocity or angular velocity of rotation parameters of the output element of hydraulic motor determine the main output parameters of the hydraulic drive and the useful power of the hydraulic drive under development. The value of the overall efficiency of the hydraulic drive enables us to judge the efficiency of high-performance fixed fluid power drive.The energy analysis of a diagram of the high-performance fixed fluid power drive shows that its high efficiency is achieved when the flow rate of fluid flowing into each cylinder and the magnitude of the feed pump unit (pump are as nearly as possible.The paper considers the ways of determining the geometric parameters of working hydromotors (effective working area or working volume, which allow a selection of the pumping unit parameters. It discusses the ways to improve hydraulic drive efficiency. Using the principle of holding constant conductivity allows us to specify the values of the pressure losses in the hydraulic units used in noncatalog modes. In case of no exact matching between the parameters of existing hydraulic power modes and a proposed characteristics of the pump unit, the nearest to the expected characteristics is taken as a working version.All of the steps allow us to create the high-performance fixed fluid power drive capable of operating at the required power and kinematic parameters with high efficiency.

  18. Displacement in new economy labor markets: Post-displacement wage loss in high tech versus low tech cities.

    Science.gov (United States)

    Davis, Daniel J; Rubin, Beth A

    2016-11-01

    While scholars and politicians tout education as the salve to employment disruptions, we argue that the geography of the new economy, and the social closure mechanisms that geography creates, may be just as important as individuals' characteristics for predicting post-displacement wage loss (or gain). We use data from the 2012 Displaced Workers ement of the Current Population Survey and from the 2010 United States Census to test hypotheses linking local labor markets in different industrial contexts to post-displacement wage loss. Our results point to age as a closure mechanism, and to the partially protective effect of education in high-tech versus low-tech economic sectors. This study is the first to use national level data to examine how employment in high-tech cities influences post-displacement wages. These findings are relevant both for theorizing about the new economy and for public policy. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Displacement measurement system for linear array detector

    International Nuclear Information System (INIS)

    Zhang Pengchong; Chen Ziyu; Shen Ji

    2011-01-01

    It presents a set of linear displacement measurement system based on encoder. The system includes displacement encoders, optical lens and read out circuit. Displacement read out unit includes linear CCD and its drive circuit, two amplifier circuits, second order Butterworth low-pass filter and the binarization circuit. The coding way is introduced, and various parts of the experimental signal waveforms are given, and finally a linear experimental test results are given. The experimental results are satisfactory. (authors)

  20. An evaluation of intrafraction motion of the prostate in the prone and supine positions using electromagnetic tracking

    International Nuclear Information System (INIS)

    Shah, Amish P.; Kupelian, Patrick A.; Willoughby, Twyla R.; Langen, Katja M.; Meeks, Sanford L.

    2011-01-01

    Purpose: To evaluate differences in target motion during prostate irradiation in the prone versus supine position using electromagnetic tracking to measure prostate mobility. Materials/methods: Twenty patients received prostate radiotherapy in the supine position utilizing the Calypso Localization System (registered) for prostate positioning and monitoring. For each patient, 10 treatment fractions were followed by a session in which the patient was repositioned prone, and prostate mobility was tracked. The fraction of time that the prostate was displaced by >3, 5, 7, and 10 mm was calculated for each patient, for both positions (400 tracking sessions). Results: Clear patterns of respiratory motion were seen in the prone tracks due to the influence of increased abdominal motion. Averaged over all patients, the prostate was displaced >3 and 5 mm for 37.8% and 10.1% of the total tracking time in the prone position, respectively. In the supine position, the prostate was displaced >3 and 5 mm for 12.6% and 2.9%, respectively. With both patient setups, inferior and posterior drifts of the prostate position were observed. Averaged over all prone tracking sessions, the prostate was displaced >3 mm in the posterior and inferior directions for 11.7% and 9.5% of the total time, respectively. Conclusions: With real-time tracking of the prostate, it is possible to study the effects of different setup positions on the prostate mobility. The percentage of time the prostate moved >3 and 5 mm was increased by a factor of three in the prone versus supine position. For larger displacements (>7 mm) no difference in prostate mobility was observed between prone and supine positions. To reduce rectal toxicity, radiotherapy in the prone position may be a suitable alternative provided respiratory motion is accounted for during treatment. Acute and late toxicity results remain to be evaluated for both patient positions.

  1. Rapid sampling of stochastic displacements in Brownian dynamics simulations with stresslet constraints

    Science.gov (United States)

    Fiore, Andrew M.; Swan, James W.

    2018-01-01

    Brownian Dynamics simulations are an important tool for modeling the dynamics of soft matter. However, accurate and rapid computations of the hydrodynamic interactions between suspended, microscopic components in a soft material are a significant computational challenge. Here, we present a new method for Brownian dynamics simulations of suspended colloidal scale particles such as colloids, polymers, surfactants, and proteins subject to a particular and important class of hydrodynamic constraints. The total computational cost of the algorithm is practically linear with the number of particles modeled and can be further optimized when the characteristic mass fractal dimension of the suspended particles is known. Specifically, we consider the so-called "stresslet" constraint for which suspended particles resist local deformation. This acts to produce a symmetric force dipole in the fluid and imparts rigidity to the particles. The presented method is an extension of the recently reported positively split formulation for Ewald summation of the Rotne-Prager-Yamakawa mobility tensor to higher order terms in the hydrodynamic scattering series accounting for force dipoles [A. M. Fiore et al., J. Chem. Phys. 146(12), 124116 (2017)]. The hydrodynamic mobility tensor, which is proportional to the covariance of particle Brownian displacements, is constructed as an Ewald sum in a novel way which guarantees that the real-space and wave-space contributions to the sum are independently symmetric and positive-definite for all possible particle configurations. This property of the Ewald sum is leveraged to rapidly sample the Brownian displacements from a superposition of statistically independent processes with the wave-space and real-space contributions as respective covariances. The cost of computing the Brownian displacements in this way is comparable to the cost of computing the deterministic displacements. The addition of a stresslet constraint to the over-damped particle

  2. Job Displacement and First Birth Over the Business Cycle.

    Science.gov (United States)

    Hofmann, Barbara; Kreyenfeld, Michaela; Uhlendorff, Arne

    2017-06-01

    In this article, we investigate the impact of job displacement on women's first-birth rates as well as the variation in this effect over the business cycle. We use mass layoffs to estimate the causal effects of involuntary job loss on fertility in the short and medium term, up to five years after displacement. Our analysis is based on rich administrative data from Germany, with an observation period spanning more than 20 years. We apply inverse probability weighting (IPW) to flexibly control for the observed differences between women who were and were not displaced. To account for the differences in the composition of the women who were displaced in a downturn and the women who were displaced in an upswing, we use a double weighting estimator. Results show that the extent to which job displacement has adverse effects on fertility depends on the business cycle. The first-birth rates were much lower for women who were displaced in an economic downturn than for those who lost a job in an economic upturn. This result cannot be explained by changes in the observed characteristics of the displaced women over the business cycle.

  3. ARTHROSCOPIC FIXATION OF ANTERIOR CRUCIATE LIGAMENT TIBIAL AVULSION FRACTURES USING FIBRE WIRE WITH OR WITHOUT ENDOBUTTON

    Directory of Open Access Journals (Sweden)

    Satyajeet Jagtap

    2017-06-01

    Full Text Available BACKGROUND Anterior Cruciate Ligament (ACL avulsion fracture is commonly associated with knee injuries and its management is controversial ranging from conservative treatment to various modalities in arthroscopic fixation. The aim of our study is to assess the clinical and radiological results of arthroscopic fixation using fibre wire with or without Endobutton in the management of ACL avulsion fractures using a simpler technique. MATERIALS AND METHODS Fifteen patients (10 males and 5 females who underwent arthroscopic fixation with standard anteromedial and anterolateral ports using fibre wire with or without Endobutton (9 cases only fibre wire was used, 6 cases Endobutton was used in addition for displaced ACL avulsion fractures (Meyers and McKeever’s classification grade 2, grade 3 and grade 4 were analysed. The average age was 26.1 years with a mean follow up of 1 year. All patients were assessed clinically by calculating their Lysholm scores, Lachman test and the radiological union was assessed in the follow up radiographs. Study Design- Retrospective observational case series. RESULTS The mean Lysholm score was 94.93 ± 2.81 (mean ± SD. In 14 patients, Lachman test was negative at the end of final follow up while 1 patient had grade I laxity compared to normal knee. At final followup, all the patients were able to return to their preinjury activity level except one who had an extension lag, underwent arthrolysis subsequently and is improving. CONCLUSION Arthroscopic fixation using this technique of using fibre wire with or without Endobutton is a safe and reliable technique for producing clinicoradiological outcome in displaced ACL avulsion fractures.

  4. On the Morphological Description of Tracheal and Esophageal Displacement and Its Phylogenetic Distribution in Avialae

    Science.gov (United States)

    Klingler, Jeremy J.

    2016-01-01

    This research examines the evolution and phylogenetic distribution of a peculiar and often overlooked character seen in birds, herein called tracheal and esophageal displacement. Tracheal and esophageal displacement refers to an asymmetrically situated trachea and/or esophagus along the length of the neck. This contrasts with what would be perceived as the “normal” (midsagittal) placement of these organs, wherein the two organs are situated along the ventral midline of the neck with no deviation. A total of forty-two bird species were examined (thirty-six of which came from dissections whereas six came from comments from previous literature or personal observations), as well as turtles, lizards, crocodylians, and mammals. This study found that essentially all birds have a laterally displaced trachea and/or esophagus. Lizards and mammals were seen to have normal, midsagittally placed tracheae and esophagi. Crocodylians were interesting in that alligators were defined by a normally situated trachea and esophagus whereas some crocodiles were characterized by displacement. In birds, the displacement may occur gradually along the neck, or it may happen immediately upon exiting the oropharynx. Displacement of these organs in birds is the result of a heavily modified neck wherein muscles that restrict mobility of the trachea and esophagus in lizards, alligators, and mammals (e.g., m. episternocleidomastoideus, m. omohyoideus, and m. sternohyoideus) no longer substantially restrict positions of the trachea and esophagus in birds. Rather, these muscles are modified in ways which may assist with making tracheal movements. The implications of this study may provide interesting insights for future comparisons in extinct taxa. PMID:27648952

  5. On the Morphological Description of Tracheal and Esophageal Displacement and Its Phylogenetic Distribution in Avialae.

    Directory of Open Access Journals (Sweden)

    Jeremy J Klingler

    Full Text Available This research examines the evolution and phylogenetic distribution of a peculiar and often overlooked character seen in birds, herein called tracheal and esophageal displacement. Tracheal and esophageal displacement refers to an asymmetrically situated trachea and/or esophagus along the length of the neck. This contrasts with what would be perceived as the "normal" (midsagittal placement of these organs, wherein the two organs are situated along the ventral midline of the neck with no deviation. A total of forty-two bird species were examined (thirty-six of which came from dissections whereas six came from comments from previous literature or personal observations, as well as turtles, lizards, crocodylians, and mammals. This study found that essentially all birds have a laterally displaced trachea and/or esophagus. Lizards and mammals were seen to have normal, midsagittally placed tracheae and esophagi. Crocodylians were interesting in that alligators were defined by a normally situated trachea and esophagus whereas some crocodiles were characterized by displacement. In birds, the displacement may occur gradually along the neck, or it may happen immediately upon exiting the oropharynx. Displacement of these organs in birds is the result of a heavily modified neck wherein muscles that restrict mobility of the trachea and esophagus in lizards, alligators, and mammals (e.g., m. episternocleidomastoideus, m. omohyoideus, and m. sternohyoideus no longer substantially restrict positions of the trachea and esophagus in birds. Rather, these muscles are modified in ways which may assist with making tracheal movements. The implications of this study may provide interesting insights for future comparisons in extinct taxa.

  6. Stability of Miscible Displacements Across Stratified Porous Media

    Energy Technology Data Exchange (ETDEWEB)

    Shariati, Maryam; Yortsos, Yanis C.

    2000-09-11

    This report studied macro-scale heterogeneity effects. Reflecting on their importance, current simulation practices of flow and displacement in porous media were invariably based on heterogeneous permeability fields. Here, it was focused on a specific aspect of such problems, namely the stability of miscible displacements in stratified porous media, where the displacement is perpendicular to the direction of stratification.

  7. Atomic displacements in bcc dilute alloys

    Indian Academy of Sciences (India)

    We present here a systematic investigation of the atomic displacements in bcc transition metal (TM) dilute alloys. We have calculated the atomic displacements in bcc (V, Cr, Fe, Nb, Mo, Ta and W) transition metals (TMs) due to 3d, 4d and 5d TMs at the substitutional site using the Kanzaki lattice static method. Wills and ...

  8. Internal Displacement, the Guiding Principles on Internal Displacement, the Principles Normative Status, and the Need for their Effective Domestic Implementation in Colombia.

    Directory of Open Access Journals (Sweden)

    Robert K. Goldman

    2010-05-01

    Full Text Available The paper briefly examines the phenomenon of internal displacement world-wide and the genesis of the United Nation’s mandate to deal with this problem. It examines key conclusions of a UN sponsored study which found that existing international law contained signifi cant gaps and grey areas in terms of meeting the needs of internally displaced persons. It also examines the origins and the content of the Guiding Principles on Internal Displacement and the normative status of these Principles. It suggests that, while not binding as such on states, the Guiding Principles have nonetheless become the most authoritative expression of minimum international standards applicable to the internally displaced and that based on state practice many, if not all, of these principles may eventually become part of customary international law. The paper also discusses the need for effective domestic implementation of the Guiding Principles, and examines how governmental authorities, the Constitutional Court and civil society organizations in Colombia, as well as inter-governmental bodies, have responded to the crisis of internal displacement in the country. While noting the adequacy of Colombia’s legislative framework on internal displacement, the paper concludes that the State has not taken the measures required to prevent future displacement or to effectively meet the protection and assistance needs of its displaced citizens.

  9. The Effect of Basepair Mismatch on DNA Strand Displacement

    OpenAIRE

    Broadwater, D.?W.?Bo; Kim, Harold?D.

    2016-01-01

    DNA strand displacement is a key reaction in DNA homologous recombination and DNA mismatch repair and is also heavily utilized in DNA-based computation and locomotion. Despite its ubiquity in science and engineering, sequence-dependent effects of displacement kinetics have not been extensively characterized. Here, we measured toehold-mediated strand displacement kinetics using single-molecule fluorescence in the presence of a single base pair mismatch. The apparent displacement rate varied si...

  10. The role of environmental degradation in population displacement.

    Science.gov (United States)

    Lonergan, S

    1998-01-01

    This article answers a series of questions about the role of environmental degradation in population displacement, refugee movement, and migration. The environment tends not to be included in the reasons for migration. Roger's indicators of migration potential include population growth, economic restructuring, increased economic disparities, and increased refugee flows. Myers (1993) estimated that international displacement and internal displacement may amount to about 25 million and may rise to 150 million by 2050. The role of the environment in displacement must be examined in the broader political and cultural context. Definitions of environmental refugees are ambiguous and inconsistent, and research has not answered why people continue to move to Mexico City and Chongqing, China, which both have very high levels of pollution. El-Hinnawi (1985) defined 3 groups of environmental refugees: those displaced due to natural disasters; those displaced due to permanent habitat changes; and those displaced who migrated from areas that cannot support their basic needs and who desire an improved quality of life. Lonergan (1994) identified environmental stresses as natural disasters, cumulative or slow-onset changes, accidental disruptions or industrial accidents, development projects, and conflict and warfare. These 5 causes must be treated separately and not lumped together as environmental degradation. Shoreline erosion, coastal flooding, and agricultural disruption associated with climate change may increase migration. Global measures must address world poverty and promote sustainable development.

  11. Shore line displacement in Oeregrundsgrepen

    International Nuclear Information System (INIS)

    Brydsten, Lars

    1999-12-01

    This report is a part of the SKB project 'SAFE' (Safety Assessment of the Final Repository of Radioactive Operational Waste). The aim of project SAFE is to update the previous safety analysis of SFR-1. The analysis is to be presented to the Swedish authorities not later than the end of 2000. SFR-1 is a facility for disposal of low and intermediate level radioactive waste and is situated in bedrock beneath the Baltic Sea, 1 km off the coast near the Forsmark nuclear power plant in Northern Uppland. The shore displacement in the Oeregrundsgrepen area is at present approximately 60 cm per 100 years and is slowly decreasing, but will still be substantial for many thousands of years. Since Oeregrundsgrepen is a relatively shallow part of the Bothnian Sea, the positive shore displacement will greatly effect the proportions of land and sea in the future. Within 2000 years (4000 AD) half of the current water area in Oeregrundsgrepen will be land and the water volume will be decreased with two thirds. At 7000 AD, the whole Oeregrundsgrepen area will be without brackish water. The effects on the landscape evolution due to shore displacement in the Oeregrundsgrepen area are illustrated in a chronological series of digital maps in Power Point format available saved on the supplied CD-rom and entitled 'Elevation.ppt '. The bedrock tectonics in the area are in two dominating directions: one northern that can be seen in the west shoreline of the island Graesoe and one in a north-westerly direction seen in the shoreline of the mainland. Many of the large basins that will be established in the area due to the shore displacement will be elongated in one of these directions. Some of the basins are relatively shallow and therefore probably will be totally filled with organic rich sediments and will form peat or bogs. Other basins, especially Graesoeraennan (the deep channel on the west side of Graesoe) are deep basins and will form a long chain of deep lakes. One of the deeper basins

  12. Shore line displacement in Oeregrundsgrepen

    Energy Technology Data Exchange (ETDEWEB)

    Brydsten, Lars [Umeaa Univ. (Sweden). Dept. of Ecology and Environmental Science

    1999-12-15

    This report is a part of the SKB project 'SAFE' (Safety Assessment of the Final Repository of Radioactive Operational Waste). The aim of project SAFE is to update the previous safety analysis of SFR-1. The analysis is to be presented to the Swedish authorities not later than the end of 2000. SFR-1 is a facility for disposal of low and intermediate level radioactive waste and is situated in bedrock beneath the Baltic Sea, 1 km off the coast near the Forsmark nuclear power plant in Northern Uppland. The shore displacement in the Oeregrundsgrepen area is at present approximately 60 cm per 100 years and is slowly decreasing, but will still be substantial for many thousands of years. Since Oeregrundsgrepen is a relatively shallow part of the Bothnian Sea, the positive shore displacement will greatly effect the proportions of land and sea in the future. Within 2000 years (4000 AD) half of the current water area in Oeregrundsgrepen will be land and the water volume will be decreased with two thirds. At 7000 AD, the whole Oeregrundsgrepen area will be without brackish water. The effects on the landscape evolution due to shore displacement in the Oeregrundsgrepen area are illustrated in a chronological series of digital maps in Power Point format available saved on the supplied CD-rom and entitled 'Elevation.ppt '. The bedrock tectonics in the area are in two dominating directions: one northern that can be seen in the west shoreline of the island Graesoe and one in a north-westerly direction seen in the shoreline of the mainland. Many of the large basins that will be established in the area due to the shore displacement will be elongated in one of these directions. Some of the basins are relatively shallow and therefore probably will be totally filled with organic rich sediments and will form peat or bogs. Other basins, especially Graesoeraennan (the deep channel on the west side of Graesoe) are deep basins and will form a long chain of deep lakes. One

  13. Modeling of displacement damage in silicon carbide detectors resulting from neutron irradiation

    Science.gov (United States)

    Khorsandi, Behrooz

    There is considerable interest in developing a power monitor system for Generation IV reactors (for instance GT-MHR). A new type of semiconductor radiation detector is under development based on silicon carbide (SiC) technology for these reactors. SiC has been selected as the semiconductor material due to its superior thermal-electrical-neutronic properties. Compared to Si, SiC is a radiation hard material; however, like Si, the properties of SiC are changed by irradiation by a large fluence of energetic neutrons, as a consequence of displacement damage, and that irradiation decreases the life-time of detectors. Predictions of displacement damage and the concomitant radiation effects are important for deciding where the SiC detectors should be placed. The purpose of this dissertation is to develop computer simulation methods to estimate the number of various defects created in SiC detectors, because of neutron irradiation, and predict at what positions of a reactor, SiC detectors could monitor the neutron flux with high reliability. The simulation modeling includes several well-known---and commercial---codes (MCNP5, TRIM, MARLOWE and VASP), and two kinetic Monte Carlo codes written by the author (MCASIC and DCRSIC). My dissertation will highlight the displacement damage that may happen in SiC detectors located in available positions in the OSURR, GT-MHR and IRIS. As extra modeling output data, the count rates of SiC for the specified locations are calculated. A conclusion of this thesis is SiC detectors that are placed in the thermal neutron region of a graphite moderator-reflector reactor have a chance to survive at least one reactor refueling cycle, while their count rates are acceptably high.

  14. CENTIMETER COSMO-SKYMED RANGE MEASUREMENTS FOR MONITORING GROUND DISPLACEMENTS

    Directory of Open Access Journals (Sweden)

    F. Fratarcangeli

    2016-06-01

    Full Text Available The SAR (Synthetic Aperture Radar imagery are widely used in order to monitor displacements impacting the Earth surface and infrastructures. The main remote sensing technique to extract sub-centimeter information from SAR imagery is the Differential SAR Interferometry (DInSAR, based on the phase information only. However, it is well known that DInSAR technique may suffer for lack of coherence among the considered stack of images. New Earth observation SAR satellite sensors, as COSMO-SkyMed, TerraSAR-X, and the coming PAZ, can acquire imagery with high amplitude resolutions too, up to few decimeters. Thanks to this feature, and to the on board dual frequency GPS receivers, allowing orbits determination with an accuracy at few centimetres level, the it was proven by different groups that TerraSAR-X imagery offer the capability to achieve, in a global reference frame, 3D positioning accuracies in the decimeter range and even better just exploiting the slant-range measurements coming from the amplitude information, provided proper corrections of all the involved geophysical phenomena are carefully applied. The core of this work is to test this methodology on COSMO-SkyMed data acquired over the Corvara area (Bolzano – Northern Italy, where, currently, a landslide with relevant yearly displacements, up to decimeters, is monitored, using GPS survey and DInSAR technique. The leading idea is to measure the distance between the satellite and a well identifiable natural or artificial Persistent Scatterer (PS, taking in account the signal propagation delays through the troposphere and ionosphere and filtering out the known geophysical effects that induce periodic and secular ground displacements. The preliminary results here presented and discussed indicate that COSMO-SkyMed Himage imagery appear able to guarantee a displacements monitoring with an accuracy of few centimetres using only the amplitude data, provided few (at least one stable PS’s are

  15. Displacement laser interferometry with sub-nanometer uncertainty

    NARCIS (Netherlands)

    Cosijns, S.J.A.G.

    2004-01-01

    Development in industry is asking for improved resolution and higher accuracy in mechanical measurement. Together with miniaturization the demand for sub nanometer uncertainty on dimensional metrology is increasing rapidly. Displacement laser interferometers are used widely as precision displacement

  16. Efficiency of a variable displacement open circuit floating cup pump

    NARCIS (Netherlands)

    Vael, G.E.M.; Achten, P.A.J.; Brink, van den T.L.

    2009-01-01

    The Floating Cup Displacement principle is a relatively new axial piston displacement principle for hydrostatic pumps, motors and transformers. Since its origin in 2001, it has been mainly applied in fixed displacement pump prototypes. At the SICFP’05, a design for a variable displacement open

  17. Epitaxial growth by monolayer restricted galvanic displacement

    Directory of Open Access Journals (Sweden)

    Vasilić Rastko

    2012-01-01

    Full Text Available The development of a new method for epitaxial growth of metals in solution by galvanic displacement of layers pre-deposited by underpotential deposition (UPD was discussed and experimentally illustrated throughout the lecture. Cyclic voltammetry (CV and scanning tunneling microscopy (STM are employed to carry out and monitor a “quasi-perfect”, two-dimensional growth of Ag on Au(111, Cu on Ag(111, and Cu on Au(111 by repetitive galvanic displacement of underpotentially deposited monolayers. A comparative study emphasizes the displacement stoichiometry as an efficient tool for thickness control during the deposition process and as a key parameter that affects the deposit morphology. The excellent quality of layers deposited by monolayer-restricted galvanic displacement is manifested by a steady UPD voltammetry and ascertained by a flat and uniform surface morphology maintained during the entire growth process.

  18. Study of a Modified Displacement Transducer of a Piston in a Power Cylinder

    Directory of Open Access Journals (Sweden)

    S. C. BERA

    2011-05-01

    Full Text Available The position monitoring of the piston inside a power cylinder is very important in process plant measurement and control. In the present paper a modified inductance type position sensing technique of a power cylinder piston has been described. A modified inductance measuring transducer circuit has been designed to measure the change of inductance of a very high inductance coil. The theoretical equations of the proposed inductive sensor and the displacement transducer have been derived. The transducer has been experimentally tested and the experimental data are presented in the paper.

  19. Radial displacement of clinical target volume in node negative head and neck cancer

    International Nuclear Information System (INIS)

    Jeon, Wan; Wu, Hong Gyun; Song, Sang Hyuk; Kim, Jung In

    2012-01-01

    To evaluate the radial displacement of clinical target volume in the patients with node negative head and neck (H and N) cancer and to quantify the relative positional changes compared to that of normal healthy volunteers. Three node-negative H and N cancer patients and fi ve healthy volunteers were enrolled in this study. For setup accuracy, neck thermoplastic masks and laser alignment were used in each of the acquired computed tomography (CT) images. Both groups had total three sequential CT images in every two weeks. The lymph node (LN) level of the neck was delineated based on the Radiation Therapy Oncology Group (RTOG) consensus guideline by one physician. We use the second cervical vertebra body as a reference point to match each CT image set. Each of the sequential CT images and delineated neck LN levels were fused with the primary image, then maximal radial displacement was measured at 1.5 cm intervals from skull base (SB) to caudal margin of LN level V, and the volume differences at each node level were quantified. The mean radial displacements were 2.26 (±1.03) mm in the control group and 3.05 (±1.97) in the H and N cancer patients. There was a statistically significant difference between the groups in terms of the mean radial displacement (p = 0.03). In addition, the mean radial displacement increased with the distance from SB. As for the mean volume differences, there was no statistical significance between the two groups. This study suggests that a more generous radial margin should be applied to the lower part of the neck LN for better clinical target coverage and dose delivery.

  20. An ion displacement membrame model.

    Science.gov (United States)

    Hladky, S B; Harris, J D

    1967-09-01

    The usual assumption in treating the diffusion of ions in an electric field has been that the movement of each ion is independent of the movement of the others. The resulting equation for diffusion by a succession of spontaneous jumps has been well stated by Parlin and Eyring. This paper will consider one simple case in which a different assumption is reasonable. Diffusion of monovalent positive ions is considered as a series of jumps from one fixed negative site to another. The sites are assumed to be full (electrical neutrality). Interaction occurs by the displacement of one ion by another. An ion leaves a site if and only if another ion, not necessarily of the same species, attempts to occupy the same site. Flux ratios and net fluxes are given as functions of the electrical potential, concentration ratios, and number of sites encountered in crossing the membrane. Quantitative comparisons with observations of Hodgkin and Keynes are presented.

  1. Measurements of the gap/displacement and development of the ultrasonic temperature measuring system applied to severe accidents research

    International Nuclear Information System (INIS)

    Koo, Kil Mo; Kang, Kyung Ho; Cho, Young Ro; Park, Rae Jun; Kim, Sang Baik; Sim, Chul Moo

    2001-02-01

    This report, in order to measure quantitative LAVA experimental results, focuses on measuring the gap formed on the lower head vessel using a ultrasonic pulse echo method and neutron radiography, measuring displacement of the lower head vessel using capacitance method, building a measuring system and developing high temperature measurement system using ultrasonic method. The scope of gap measurement and system development using the ultrasonic method is 2-dimensional image processing using tomographical B scan method and 2- and 3-dimensional image processing using C scan methods based on the one dimensional time domain A scan signal. For some test specimen, the gap size is quantitative represented apply C scan methods. The important ultrasonic image processing technique is on the development of accurate position control system. The requirements of the position control system are a contact technique on the test specimen and a fine moving technique. Since the specimen is hemispherical, the contact technique is very difficult. Therefore, the gap measurement using the ultrasonic pulse echo method was applied developing the position controlling scanner system. Along with the ultrasonic method, neutron radiography method using KAERI's neutron source was attempted 4 times and the results are compared. The fine displacement of the hemispherical specimen was measured using a capacitive displacement sensor. The requirements for this measuring technique are fixing of the capacitance sensor to the experimental facilities and a remote control position varying system. This remote control position varying system was manufactured with a electrical motor. The development of a high temperature measuring system using a ultrasonic method the second year plan, is performed with developing a sensor which can measure up to 2300 deg C

  2. Interfractional Position Variation of Pancreatic Tumors Quantified Using Intratumoral Fiducial Markers and Daily Cone Beam Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Horst, Astrid van der, E-mail: a.vanderhorst@amc.uva.nl [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Wognum, Silvia; Dávila Fajardo, Raquel; Jong, Rianne de [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Hooft, Jeanin E. van; Fockens, Paul [Department of Gastroenterology and Hepatology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Tienhoven, Geertjan van; Bel, Arjan [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands)

    2013-09-01

    Purpose: The aim of this study was to quantify interfractional pancreatic position variation using fiducial markers visible on daily cone beam computed tomography (CBCT) scans. In addition, we analyzed possible migration of the markers to investigate their suitability for tumor localization. Methods and Materials: For 13 pancreatic cancer patients with implanted Visicoil markers, CBCT scans were obtained before 17 to 25 fractions (300 CBCTs in total). Image registration with the reference CT was used to determine the displacement of the 2 to 3 markers relative to bony anatomy and to each other. We analyzed the distance between marker pairs as a function of time to identify marker registration error (SD of linear fit residuals) and possible marker migration. For each patient, we determined the mean displacement of markers relative to the reference CT (systematic position error) and the spread in displacements (random position error). From this, we calculated the group systematic error, Σ, and group random error, σ. Results: Marker pair distances showed slight trends with time (range, −0.14 to 0.14 mm/day), possibly due to tissue deformation, but no shifts that would indicate marker migration. The mean SD of the fit residuals was 0.8 mm. We found large interfractional position variations, with for 116 of 300 (39%) fractions a 3-dimensional vector displacement of >10 mm. The spread in displacement varied significantly (P<.01) between patients, from a vector range of 9.1 mm to one of 24.6 mm. For the patient group, Σ was 3.8, 6.6, and 3.5 mm; and σ was 3.6, 4.7 and 2.5 mm, in left–right, superior–inferior, and anterior–posterior directions, respectively. Conclusions: We found large systematic displacements of the fiducial markers relative to bony anatomy, in addition to wide distributions of displacement. These results for interfractional position variation confirm the potential benefit of using fiducial markers rather than bony anatomy for daily online

  3. Positioning accuracy of the neurotron 1000

    International Nuclear Information System (INIS)

    Cox, Richard S.; Murphy, Martin J.

    1995-01-01

    Purpose: The Neurotron 1000 is a novel treatment machine under development for frameless stereotaxic radiosurgery that consists of a compact X-band accelerator mounted on a robotic arm. The therapy beam is guided to the lesion by an imaging system, which includes two diagnostic x-ray cameras that view the patient during treatment. Patient position and motion are measured by the imaging system and appropriate corrections are communicated in real time to the robotic arm for beam targeting and motion tracking. The three tests reported here measured the pointing accuracy of the therapy beam and the present capability of the imaging guidance system. Materials and Methods: 1) The positioning and pointing test measured the ability of the robotic arm to direct the beam through a test isocenter from arbitrary arm positions. The test isocenter was marked by a small light-sensitive crystal and the beam axis was simulated by a laser. The robot was directed to move the linac to a variety of positions, aiming the laser at the crystal detector from each position. The distance of the beam axis from the crystal was measured for each robot position. 2) The imaging-guidance system was tested by moving phantoms about in the field of view of the camera by precisely known displacements and comparing the guidance system's measurement of the phantom position with the its actual position. 3) The system's overall pointing and tracking capability was measured by an end-to-end test using a dosimetric phantom containing radiochromic film. The phantom was imaged by CT to locate the center of the cubical film package. A set of isocentric robotic paths was calculated to produce a spherical dose distribution at the center of the film package. The phantom with the film was then irradiated by the therapy beam as the robot executed the path, with the imaging system providing the beam targeting directions. Results: 1) The positioning and pointing test was performed for paths consisting of spirals and

  4. Myocardial strains from 3D displacement encoded magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kindberg, Katarina; Haraldsson, Henrik; Sigfridsson, Andreas; Engvall, Jan; Ingels, Neil B Jr; Ebbers, Tino; Karlsson, Matts

    2012-01-01

    The ability to measure and quantify myocardial motion and deformation provides a useful tool to assist in the diagnosis, prognosis and management of heart disease. The recent development of magnetic resonance imaging methods, such as harmonic phase analysis of tagging and displacement encoding with stimulated echoes (DENSE), make detailed non-invasive 3D kinematic analyses of human myocardium possible in the clinic and for research purposes. A robust analysis method is required, however. We propose to estimate strain using a polynomial function which produces local models of the displacement field obtained with DENSE. Given a specific polynomial order, the model is obtained as the least squares fit of the acquired displacement field. These local models are subsequently used to produce estimates of the full strain tensor. The proposed method is evaluated on a numerical phantom as well as in vivo on a healthy human heart. The evaluation showed that the proposed method produced accurate results and showed low sensitivity to noise in the numerical phantom. The method was also demonstrated in vivo by assessment of the full strain tensor and to resolve transmural strain variations. Strain estimation within a 3D myocardial volume based on polynomial functions yields accurate and robust results when validated on an analytical model. The polynomial field is capable of resolving the measured material positions from the in vivo data, and the obtained in vivo strains values agree with previously reported myocardial strains in normal human hearts

  5. Combination of coseismic displacement fields: a geodetic perspective

    Directory of Open Access Journals (Sweden)

    Roberto Devoti

    2012-10-01

    Full Text Available This study provides the mathematical framework for the rigorous combination of coseismic offsets observed by a global positioning system (GPS network and investigates the results obtained on the occasion of the recent Emilia earthquakes (Italy. This seismic sequence that affected northern Italy from May 20, 2012, allowed two offset fields to be computed, one with reference to the mainshock (M 5.9, followed by two other M 5.1 events on the same day, and a second with reference to the replicas that occurred on May 29, 2012 (M 5.8, M 5.3 and M 5.2; ISIDe data archive, http://iside.rm.ingv.it. The final displacement field is basically the result of a comparison and validation process with repeated feedback between the different analysis groups at the Istituto Nazionale di Geofisica e Vulcanologia (INGV; National Institute of Geophysics and Volcanology that was established to obtain prompt coseismic displacement solutions, as precise as possible, and in the first days after an event. This is important for early seismic-source evaluation as it represents the most complete and validated dataset at the very early stage of a seismic crisis, and it is also extremely useful in reducing random and systematic errors in the estimated parameters. This study is the result of a cooperative effort that involved different research groups at INGV, with the sharing of all of the collected GPS data. The intention was to compare these results and thus reducing sources of error associated with individual processing strategies, to allow the final combination of the different displacement fields into a single consensus solution. The process assessed the robustness of each single GPS result, thus minimizing erroneous interpretations of individual solutions. […

  6. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements.

    Science.gov (United States)

    Poder, Joel; Whitaker, May

    2016-06-01

    Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected.

  7. Violence Against Displaced Syrian Women in Lebanon.

    Science.gov (United States)

    Usta, Jinan; Masterson, Amelia Reese; Farver, JoAnn M

    2016-10-01

    This study used focus group discussions to explore 29 Syrian women's experiences of being displaced refugees in Lebanon. Women reported intimate partner violence (IPV), harassment, and community violence. They experienced difficult living conditions characterized by crowding and lack of privacy, adult unemployment, and overall feelings of helplessness. Most frequently, they used negative coping strategies, including justification and acceptance of IPV and often physically harmed their own children due to heightened stress. Some sought support from other Syrian refugee women. Although the study did not address the root causes of IPV, the results shed light on women's experiences and indicate that training them in positive coping strategies and establishing support groups would help them face IPV that occurs in refugee settings.

  8. Fiber-optic couplers as displacement sensors

    Science.gov (United States)

    Baruch, Martin C.; Gerdt, David W.; Adkins, Charles M.

    2003-04-01

    We introduce the novel concept of using a fiber-optic coupler as a versatile displacement sensor. Comparatively long fiber-optic couplers, with a coupling region of approximately 10 mm, are manufactured using standard communication SM fiber and placed in a looped-back configuration. The result is a displacement sensor, which is robust and highly sensitive over a wide dynamic range. This displacement sensor resolves 1-2 μm over distances of 1-1.5 mm and is characterized by the essential absence of a 'spring constant' plaguing other strain gauge-type sensors. Consequently, it is possible to couple to extremely weak vibrations, such as the skin displacement affected by arterial heart beat pulsations. Used as a wrist-worn heartbeat monitor, the fidelity of the arterial pulse signal has been shown to be so high that it is possible to not only determine heartbeat and breathing rates, but to implement a new single-point blood pressure measurement scheme which does not squeeze the arm. In an application as a floor vibration sensor for the non-intrusive monitoring of independently living elderly, the sensor has been shown to resolve the distinct vibration spectra of different persons and different events.

  9. Topology synthesis of large-displacement compliant mechanisms

    DEFF Research Database (Denmark)

    Pedersen, Claus B. Wittendorf; Buhl, Thomas; Sigmund, Ole

    2001-01-01

    This paper describes the use of topology optimization as a synthesis tool for the design of large-displacement compliant mechanisms. An objective function for the synthesis of large-displacement mechanisms is proposed together with a formulation for synthesis of path-generating compliant mechanisms...

  10. Prolonged displacement may compromise resilience in Eritrean ...

    African Journals Online (AJOL)

    Objective: to assess the impact of prolonged displacement on the resilience of Eritrean mothers. Methods: an adapted SOC scale (short form) was administered. Complementary qualitative data were gathered from study participants' spontaneous reactions to and commentaries on the SOC scale. Results: Displaced ...

  11. Job displacement and stress-related health outcomes

    DEFF Research Database (Denmark)

    Browning, Martin; Danø, Anne Møller; Heinesen, Eskil

    2006-01-01

    We investigate whether job loss as the result of displacement causes hospitalization for stress-related diseases which are widely thought to be associated with unemployment. In doing this, we use much better data than any previous investigators. Our data are a random 10% sample of the male...... group of displaced workers if they had not in fact been displaced. Our results indicate unequivocally that being displaced in Denmark does not cause hospitalization for stress-related disease. An analysis of the power of our test suggests that even though we are looking for a relatively rare outcome...... population of Denmark for the years 1981-1999 with full records on demographics, health and work status for each person, and with a link from every working person to a plant. We use the method of matching on observables to estimate the counter-factual of what would have happened to the health of a particular...

  12. Inertial Pocket Navigation System: Unaided 3D Positioning

    Directory of Open Access Journals (Sweden)

    Estefania Munoz Diaz

    2015-04-01

    Full Text Available Inertial navigation systems use dead-reckoning to estimate the pedestrian’s position. There are two types of pedestrian dead-reckoning, the strapdown algorithm and the step-and-heading approach. Unlike the strapdown algorithm, which consists of the double integration of the three orthogonal accelerometer readings, the step-and-heading approach lacks the vertical displacement estimation. We propose the first step-and-heading approach based on unaided inertial data solving 3D positioning. We present a step detector for steps up and down and a novel vertical displacement estimator. Our navigation system uses the sensor introduced in the front pocket of the trousers, a likely location of a smartphone. The proposed algorithms are based on the opening angle of the leg or pitch angle. We analyzed our step detector and compared it with the state-of-the-art, as well as our already proposed step length estimator. Lastly, we assessed our vertical displacement estimator in a real-world scenario. We found that our algorithms outperform the literature step and heading algorithms and solve 3D positioning using unaided inertial data. Additionally, we found that with the pitch angle, five activities are distinguishable: standing, sitting, walking, walking up stairs and walking down stairs. This information complements the pedestrian location and is of interest for applications, such as elderly care.

  13. Inertial Pocket Navigation System: Unaided 3D Positioning

    Science.gov (United States)

    Munoz Diaz, Estefania

    2015-01-01

    Inertial navigation systems use dead-reckoning to estimate the pedestrian's position. There are two types of pedestrian dead-reckoning, the strapdown algorithm and the step-and-heading approach. Unlike the strapdown algorithm, which consists of the double integration of the three orthogonal accelerometer readings, the step-and-heading approach lacks the vertical displacement estimation. We propose the first step-and-heading approach based on unaided inertial data solving 3D positioning. We present a step detector for steps up and down and a novel vertical displacement estimator. Our navigation system uses the sensor introduced in the front pocket of the trousers, a likely location of a smartphone. The proposed algorithms are based on the opening angle of the leg or pitch angle. We analyzed our step detector and compared it with the state-of-the-art, as well as our already proposed step length estimator. Lastly, we assessed our vertical displacement estimator in a real-world scenario. We found that our algorithms outperform the literature step and heading algorithms and solve 3D positioning using unaided inertial data. Additionally, we found that with the pitch angle, five activities are distinguishable: standing, sitting, walking, walking up stairs and walking down stairs. This information complements the pedestrian location and is of interest for applications, such as elderly care. PMID:25897501

  14. Differential optical shadow sensor for sub-nanometer displacement measurement and its application to drag-free satellites.

    Science.gov (United States)

    Zoellner, Andreas; Tan, Si; Saraf, Shailendhar; Alfauwaz, Abdul; DeBra, Dan; Buchman, Sasha; Lipa, John A

    2017-10-16

    We present a method for 3D sub-nanometer displacement measurement using a set of differential optical shadow sensors. It is based on using pairs of collimated beams on opposite sides of an object that are partially blocked by it. Applied to a sphere, our 3-axis sensor module consists of 8 parallel beam-detector sets for redundancy. The sphere blocks half of each beam's power in the nominal centered position, and any displacement can be measured by the differential optical power changes amongst the pairs of detectors. We have experimentally demonstrated a displacement sensitivity of 0.87nm/Hz at 1 Hz and 0.39nm/Hz at 10 Hz. We describe the application of the module to the inertial sensor of a drag-free satellite, which can potentially be used for navigation, geodesy and fundamental science experiments as well as ground based applications.

  15. On virtual displacement and virtual work in Lagrangian dynamics

    International Nuclear Information System (INIS)

    Ray, Subhankar; Shamanna, J

    2006-01-01

    The confusion and ambiguity encountered by students in understanding virtual displacement and virtual work is discussed in this paper. A definition of virtual displacement is presented that allows one to express them explicitly for holonomic (velocity independent), non-holonomic (velocity dependent), scleronomous (time independent) and rheonomous (time dependent) constraints. It is observed that for holonomic, scleronomous constraints, the virtual displacements are the displacements allowed by the constraints. However, this is not so for a general class of constraints. For simple physical systems, it is shown that the work done by the constraint forces on virtual displacements is zero. This motivates Lagrange's extension of d'Alembert's principle to a system of particles in constrained motion. However, a similar zero work principle does not hold for the allowed displacements. It is also demonstrated that d'Alembert's principle of zero virtual work is necessary for the solvability of a constrained mechanical problem. We identify this special class of constraints, physically realized and solvable, as the ideal constraints. The concept of virtual displacement and the principle of zero virtual work by constraint forces are central to both Lagrange's method of undetermined multipliers and Lagrange's equations in generalized coordinates

  16. 2014 and beyond: implications for displacement

    Directory of Open Access Journals (Sweden)

    Aidan O’Leary

    2014-05-01

    Full Text Available 2014 marks a watershed for Afghanistan, with the withdrawal of the International Security Assistance Force after twelve years, and the very real risks this withdrawal poses to the capacity of the Afghan state to meet the many internal and external challenges faced by the country. These challenges have significant implications for displaced and returning Afghans and for the potential for displacement in the future.

  17. Minimization of small bowel volume within treatment fields using customized small bowel displacement system (SBDS)

    International Nuclear Information System (INIS)

    Lim, D. H.; Huh, S. J.; Ahn, Y. C.; Kim, D. Y.; Wu, H. G.; Kim, M. K.; Choi, D. R.; Shin, K. H.

    1997-01-01

    Authors designed a customized Small Bowel Displacement System(SBDS) to displace the small bowel from the pelvic radiation fields and minimize treatment-related bowel morbidities. From August 1995 to May 1996, 55 consecutive patients who received pelvic radiation therapy with the SBDS were included in this study. The SBDS consists of a customized styrofoam compression device which can displace the small bowel from the radiation fields and an individualized immobilization abdominal board for easy daily setup in prone position. After opacifying the small bowel with Barium, the patients were laid prone and posterior-anterior (PA) and lateral (LAT) simulation films were taken with and without the SBDS. The areas of the small bowel included in the radiation fields with and without the SBDS were compared. Using the SBDS, the mean small bowel area was reduced by 59% on PA and 51% on LAT films (P=0.0001). In six patients (6/55, 11%), it was possible that no small bowel was included within the treatment fields. The mean upward displacement of the most caudal small bowel was 4.8 cm using the SBDS. Only 15% (8/55) of patients treated with the SBDS manifested diarrhea requiring medication. The SBDS is a novel method that can be used to displace the small bowel away from the treatment portal effectively and reduce the radiation therapy morbidities. Compliance with setup is excellent when the SBDS is used. (author)

  18. Displacement Ventilation in a Room with Low-Level Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    Ventilation systems with vertical displacement flow have been used in industrial areas with high thermal loads for many years. Quite resently the vertical displacement flow systems have grown popular as comfort ventilation in rooms with thermal loads e.g. offices.......Ventilation systems with vertical displacement flow have been used in industrial areas with high thermal loads for many years. Quite resently the vertical displacement flow systems have grown popular as comfort ventilation in rooms with thermal loads e.g. offices....

  19. [Investigation of RNA viral genome amplification by multiple displacement amplification technique].

    Science.gov (United States)

    Pang, Zheng; Li, Jian-Dong; Li, Chuan; Liang, Mi-Fang; Li, De-Xin

    2013-06-01

    In order to facilitate the detection of newly emerging or rare viral infectious diseases, a negative-strand RNA virus-severe fever with thrombocytopenia syndrome bunyavirus, and a positive-strand RNA virus-dengue virus, were used to investigate RNA viral genome unspecific amplification by multiple displacement amplification technique from clinical samples. Series of 10-fold diluted purified viral RNA were utilized as analog samples with different pathogen loads, after a series of reactions were sequentially processed, single-strand cDNA, double-strand cDNA, double-strand cDNA treated with ligation without or with supplemental RNA were generated, then a Phi29 DNA polymerase depended isothermal amplification was employed, and finally the target gene copies were detected by real time PCR assays to evaluate the amplification efficiencies of various methods. The results showed that multiple displacement amplification effects of single-strand or double-strand cDNA templates were limited, while the fold increases of double-strand cDNA templates treated with ligation could be up to 6 X 10(3), even 2 X 10(5) when supplemental RNA existed, and better results were obtained when viral RNA loads were lower. A RNA viral genome amplification system using multiple displacement amplification technique was established in this study and effective amplification of RNA viral genome with low load was achieved, which could provide a tool to synthesize adequate viral genome for multiplex pathogens detection.

  20. MRI of radial displacement of the meniscus in the knee

    International Nuclear Information System (INIS)

    Chen Jian; Lv Houshan; Lao Shan; Guan Zhenpeng; Hong Nan; Liang Hao

    2006-01-01

    Objective: To describe the phenomenon of radial displacement of the meniscus of the knees in the study population with MR imaging, and to establish MRI diagnostic criteria for radial displacement of the meniscus and displacement index. Methods: MR signs of radial displacement of the meniscus were evaluated retrospectively in 398 patients with knee symptoms who were examined with non- weight bearing MR images from Jan. 2000 to Feb. 2004. The patients younger than 18 years old, with joint effusion or serious arthropathy were excluded and 312 patients were eligible to be enrolled in this study. The criterion for radial displacement of the meniscus was defined as the location of the edge of meniscal body beyond the femoral and tibial outer border line. A displacement index, defined as the ratio of meniscal overhang to meniscal width, was used to quantify meniscal displacement. Results: The prevalence of radial displacement of the meniscus was 16.7% (52/312) and 13.9% (21/151) in right knee and 19.3% (31/161 )in left knee, respectively. There was no significant difference between left and right knee (χ 2 =1.60, P>0.05) and the ratio between medial and lateral meniscus was 7.8:1. The average displacement index was 0.54±0.24. The displacement indices were significant higher in older group (F=3.63, P<0.05). The incidence and indices of radial displacement of the meniscus for patients under or above 50 year older were 12.0%(17/142), 0.46±0.22 and 20.6% (35/170), 0.64±0.20, respectively. Difference was highly significant (t=0.84, P<0.01). Conclusion: It was concluded that radial displacement of the meniscus in knees was not a rare finding with MR imaging in patients with knee symptoms. The incidence increased in older age group. Further investigations were recommended to understand the etiology and clinical significance of the phenomenon of radial displacement of the meniscus. (authors)

  1. Overtreatment of displaced midshaft clavicle fractures

    DEFF Research Database (Denmark)

    Ban, Ilija; Nowak, Jan; Virtanen, Kaisa

    2016-01-01

    Background and purpose - The best treatment for displaced clavicle fractures has been debated for decades. Operative treatment has become more common. However, several randomized trials comparing non-operative and operative treatment have not shown any compelling evidence in favor of surgery. We...... identified the preferred treatment of displaced midshaft clavicle fractures at public hospitals in 3 countries in Scandinavia. Patients and methods - A purpose-made multiple-choice questionnaire in English was sent to all public hospitals in Denmark, Sweden, and Finland. This was addressed to the orthopedic...... surgeon responsible for treatment of clavicle fractures, and completed questionnaires were obtained from 85 of 118 hospitals. Results - In the 3 countries, 69 of the 85 hospitals that responded would treat displaced clavicle fractures operatively. Clear criteria for treatment allocation were used at 58...

  2. Arm-trunk coordination in wheelchair initiation displacement: A study of anticipatory and compensatory postural adjustments during different speeds and directions of propulsion.

    Science.gov (United States)

    Chikh, Soufien; Garnier, Cyril; Faupin, Arnaud; Pinti, Antonio; Boudet, Samuel; Azaiez, Fairouz; Watelain, Eric

    2018-03-13

    Arm-trunk coordination during the initiation of displacement in manual wheelchair is a complex task. The objective of this work is to study the arm-trunk coordination by measuring anticipatory and compensatory postural adjustments. Nine healthy subjects participated in the study after being trained in manual wheelchair. They were asked to initiate a displacement in manual wheelchair in three directions (forward vs. left vs. right), with two speeds (spontaneous vs. maximum) and with two initial hand's positions (hands on thighs vs. hands on handrails). Muscular activities in the trunk (postural component) and the arms (focal component) were recorded bilaterally. The results show two strategies for trunk control: An anticipatory adjustment strategy and a compensatory adjustment strategy with a dominance of compensation. These two strategies are influenced by the finalities of displacement in terms of speed and direction depending on the hands positions. Arm-trunk coordination is characterized by an adaptability of anticipatory and compensatory postural adjustments. The study of this type of coordination for subjects with different levels of spinal cord injury could be used to predict the forthcoming displacement and thus assist the user in a complex task. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Axial displacements in external and internal implant-abutment connection.

    Science.gov (United States)

    Lee, Ji-Hye; Kim, Dae-Gon; Park, Chan-Jin; Cho, Lee-Ra

    2014-02-01

    The purpose of this study was to evaluate the axial displacement of the abutments during clinical procedures by the tightening torque and cyclic loading. Two different implant-abutment connection systems were used (external butt joint connection [EXT]; internal tapered conical connection [INT]). The master casts with two implant replicas, angulated 10° from each other, were fabricated for each implant connection system. Four types of impression copings were assembled and tightened with the corresponding implants (hex transfer impression coping, non-hex transfer impression coping, hex pick-up impression coping, non-hex pick-up impression coping). Resin splinted abutments and final prosthesis were assembled. The axial displacement was measured from the length of each assembly, which was evaluated repeatedly, after 30 Ncm torque tightening. After 250 N cyclic loading of final prosthesis for 1,000,000 cycles, additional axial displacement was recorded. The mean axial displacement was statistically analyzed (repeated measured ANOVA). There was more axial displacement in the INT group than that of the EXT group in impression copings, resin splinted abutments, and final prosthesis. Less axial displacement was found at 1-piece non-hex transfer type impression coping than other type of impression copings in the INT group. There was more axial displacement at the final prosthesis than resin splinted abutments in the INT and the EXT groups. After 250 N cyclic loading of final prosthesis, the INT group showed more axial displacement than that of the EXT group. Internal tapered conical connection demonstrated a varying amount of axial displacement with tightening torque and cyclic loading. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  4. Employment protection and the consequences for displaced workers

    DEFF Research Database (Denmark)

    Albæk, Karsten; van Audenrode, Marc; Browning, Martin

    We compare the wage and employment consequences of a job displacement in Belgium and Denmark. These two countries both have generous unemployment insurance schemes but job protection laws vary dramatically between the two. Using comparable data we find that the incidence of displacement and the c...... and the consequences for wages are similar in the two countries. The consequences for employment are very different with Danish workers experiencing much less unemployment after a displacement...

  5. DFT study of the polarization behaviors of various distorted barium titanate crystals: The role of atomic displacements

    Science.gov (United States)

    Mirseraji, Mojtaba; Shahraki, Mehran Gholipour

    2018-06-01

    A Local Density Approximation (LDA) was employed to investigate the influence of applied strains on valence charge distributions, atomic displacements, Tisbnd O (3) bond distances and the total polarizations in barium titanate (BaTiO3). Four types of various strains were imposed on perfect tetragonal BaTiO3 along the a, c, ab and abc axial directions. Electromechanical properties of BaTiO3 were evaluated in LDA framework and a good agreement with previous results was achieved. The results show that, in the cases of a, ab strains, the values of polarization are almost constant in negative strains and increased by gradual increasing of the positive strains after a sudden enhancement at about +0.1% strain. In the case of c-strain, axial oxygen and Ti atoms underwent the highest displacements and the polarization linearly increased by applied strain. The case of abc-strain, represent the both types of features. In negative abc-strain show a similar polarization behavior like c-strain case and in positive region, polarization behavior is the same as a- and ab-strain cases. In the abc-strains of -0.3% and +0.1%, an abrupt jump in total polarization curve and a small change, are observed due to abnormal atomic displacements. In the most cases a direct relation between polarization and Tisbnd O (3) bond distance was also beheld. Finally, the effects of valence charge distributions on the atomic displacements and total polarizations are studied. It is found that there is a direct relation between polarization and Valence Charge Asymmetry of 3d -orbitals.

  6. Bucky gel actuator displacement: experiment and model

    International Nuclear Information System (INIS)

    Ghamsari, A K; Zegeye, E; Woldesenbet, E; Jin, Y

    2013-01-01

    Bucky gel actuator (BGA) is a dry electroactive nanocomposite which is driven with a few volts. BGA’s remarkable features make this tri-layered actuator a potential candidate for morphing applications. However, most of these applications would require a better understanding of the effective parameters that influence the BGA displacement. In this study, various sets of experiments were designed to investigate the effect of several parameters on the maximum lateral displacement of BGA. Two input parameters, voltage and frequency, and three material/design parameters, carbon nanotube type, thickness, and weight fraction of constituents were selected. A new thickness ratio term was also introduced to study the role of individual layers on BGA displacement. A model was established to predict BGA maximum displacement based on the effect of these parameters. This model showed good agreement with reported results from the literature. In addition, an important factor in the design of BGA-based devices, lifetime, was investigated. (paper)

  7. Displacement of organelles in plant gravireceptor cells by vibrational forces and ultrasound.

    Science.gov (United States)

    Kuznetsov, O.; Nechitailo, G.; Kuznetsov, A.

    Plant gravity perception can be studied by displacing statoliths inside receptor cells by forces other than gravity. Due to mechanical heterogeneity of statocytes various ponderomotive forces can be used for this purpose. In a plant subjected to non- symmetric vibrations statoliths experience inertial force proportional to the difference between their density and that of cytoplasm and to the instantaneous acceleration of the cell. This force causes cyclic motion of statoliths relative to cytoplasm and, depending on the profile of oscillations, can result in a net displacement of them (due to complex rheology of the cell interior), similar to sedimentation. This can be described as "vibrational" ponderomotive force acting on the statoliths. Vertically growing Arabidopsis seedlings, subjected to horizontal, sawtooth shaped oscillations (250 Hz, 1.5 mm amplitude), showed 17+/-2o root curvature toward and shoot curvature of 11+/-3o against the stronger acceleration. When the polarity of the oscillations was reversed, the direction of curvature of shoots and roots was also reversed. Control experiments with starchless mutants (TC7) produced no net curvature, which indicates that dense starch-filled amyloplasts are needed for the effect. These control experiments also eliminate touch-induced reactions or other side-effects as the cause of the curvature. Linum roots curved 25+/-7o . Ceratodon protonemata subjected to the same oscillations have shown displacement of plastids and curvature consistent with the pattern observed during graviresponse: positively gravitropic wwr mutant curved in the direction of the plastid displacement, WT curved in the opposite direction. Acoustic ponderomotive forces, originating from transfer of a sonic beam momentum to the medium due to sound scattering and attenuation in a mechanically heterogeneous system, also can displace statoliths. Vertical flax seedlings curved away from the ultrasonic source (800 kHz, 0.1 W/cm2 ) presumably as a

  8. Displacement of structures in the thorax from expiration to inspiration as estimated by computed tomography and a 3-D treatment planning system

    International Nuclear Information System (INIS)

    Garmon, Pamela; Huang, David; Lutz, Steve; Zwicker, Robert

    1996-01-01

    Purpose/Objective: The spread of image based three dimensional treatment planning and conformal radiotherapy have brought new attention to the problems of patient motion during treatment. Recent studies of the effects of breathing on the motion of internal structures have led to the suggestion that gated irradiation might improve the therapeutic benefits of conformal therapy. In the present work we investigate the displacement of tumor and other structures in the thorax with breathing in order to assess further the potential benefit of gating in the treatment of lung tumors. Materials and Methods: Thoracic CT scans were obtained for patients immediately after inspiration and after expiration. Tumor positions were assessed by computing the centers of the outlined volumes for both inspiration and expiration. Effects of breathing motion along the longitudinal direction were evaluated by using a three dimensional treatment planning system to measure the distances between scans where the top of the diaphragm was present. Displacement within the transverse direction was assessed by measuring the positions of the field skin markers, the aorta and the esophagus. Results: Movement of the centers of the tumor volumes as computed by reconstructed volumes was measured to be 0.7-1.2cm. The magnitude of this movement was greatest for tumors in the mid to lower region of the lung and was primarily in the direction of superior to inferior combined with anterior to posterior. Displacement of the diaphragm ranged 1-3 cm with breathing. Displacement of the aorta and esophagus was measured to be 0.2-1.5 cm. Movement of these structures was only analyzed transversely and showed displacement to the patients' left and posterior upon expiration. The magnitude did not appear to correlate with position relative to the diaphragm. Patients with less diaphragm movement also had smaller tidal volumes and conversely, patients with larger diaphragm displacement had greater tidal volumes

  9. Dynamics and feedback control of plasma equilibrium position in a tokamak

    International Nuclear Information System (INIS)

    Burenko, O.

    1983-01-01

    A brief history of the beginnings of nuclear fusion research involving toroidal closed-system magnetic plasma containment is presented. A tokamak machine is defined mathematically for the purposes of plasma equilibrium position perturbation analysis. The perturbation equations of a tokamak plasma equilibrium position are developed. Solution of the approximated perturbation equations is carried out. A unique, simple, and useful plasma displacement dynamics transfer function of a tokamak is developed. The dominant time constants of the dynamics transfer function are determined in a symbolic form. This symbolic form of the dynamics transfer function makes it possible to study the stability of a tokamak's plasma equilibrium position. Knowledge of the dynamics transfer function permits systematic syntheses of the required plasma displacement feedback control systems

  10. Positional and morphologic changes of the temporomandibular joint disc using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ahn, Hyoun Suk; Cho, Su Beom; Koh, Kwang Joon

    2001-01-01

    To evaluate displacement and morphologic changes of the temporomandibular joint (TMJ) disc in patient with internal derangement using magnetic resonance imaging (MRI). One hundred and forty five MR images of TMJs in 73 patients were evaluated. Positional and morphologic changes of the TMJ disc were assessed. Lateral or medial disc displacement was also evaluated on cornal images. Among 63 discs with anterior disc displacement, 37 discs were assessed as a biconcave disc and 21 as a deformed disc. Rotational disc displacement was observed in 35 disc. Anteromedial disc displacement was observed in 29 discs, and anterolateral direction in 6 discs. Among 35 rotational displacement, 5 biconcave discs and 21 deformed discs were observed. Rotational and sideways displacement of TMJ discs were found to be common and an important aspect of internal derangement. This study also suggests that sagittal and coronal images of the TMJ have complementary abilities for an assessment of joint abnormality

  11. A Vision-Based Sensor for Noncontact Structural Displacement Measurement

    Science.gov (United States)

    Feng, Dongming; Feng, Maria Q.; Ozer, Ekin; Fukuda, Yoshio

    2015-01-01

    Conventional displacement sensors have limitations in practical applications. This paper develops a vision sensor system for remote measurement of structural displacements. An advanced template matching algorithm, referred to as the upsampled cross correlation, is adopted and further developed into a software package for real-time displacement extraction from video images. By simply adjusting the upsampling factor, better subpixel resolution can be easily achieved to improve the measurement accuracy. The performance of the vision sensor is first evaluated through a laboratory shaking table test of a frame structure, in which the displacements at all the floors are measured by using one camera to track either high-contrast artificial targets or low-contrast natural targets on the structural surface such as bolts and nuts. Satisfactory agreements are observed between the displacements measured by the single camera and those measured by high-performance laser displacement sensors. Then field tests are carried out on a railway bridge and a pedestrian bridge, through which the accuracy of the vision sensor in both time and frequency domains is further confirmed in realistic field environments. Significant advantages of the noncontact vision sensor include its low cost, ease of operation, and flexibility to extract structural displacement at any point from a single measurement. PMID:26184197

  12. Comparison of 3D displacements of screw-retained zirconia implant crowns into implants with different internal connections with respect to screw tightening.

    Science.gov (United States)

    Rebeeah, Hanadi A; Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin; Clelland, Nancy; Brantley, William

    2018-01-01

    Internal conical implant-abutment connections without horizontal platforms may lead to crown displacement during screw tightening and torque application. This displacement may affect the proximal contacts and occlusion of the definitive prosthesis. The purpose of this in vitro study was to evaluate the displacement of custom screw-retained zirconia single crowns into a recently introduced internal conical seal implant-abutment connection in 3D during hand and torque driver screw tightening. Stereolithic acrylic resin models were printed using computed tomography data from a patient missing the maxillary right central incisor. Two different internal connection implant systems (both ∼11.5 mm) were placed in the edentulous site in each model using a surgical guide. Five screw-retained single zirconia computer-aided design and computer-aided manufacturing (CAD-CAM) crowns were fabricated for each system. A pair of high-resolution digital cameras was used to record the relationship of the crown to the model. The crowns were tightened according to the manufacturers' specifications using a torque driver, and the cameras recorded their relative position again. Three-dimensional image correlation was used to measure and compare crown positions, first hand tightened and then torque driven. The displacement test was repeated 3 times for each crown. Commercial image correlation software was used to extract the data and compare the amount of displacement vertically, mesiodistally, and buccolingually. Repeated-measures ANOVA calculated the relative displacements for all 5 specimens for each implant for both crown screw hand tightening and after applied torque. A Student t test with Bonferroni correction was used for pairwise comparison of interest to determine statistical differences between the 2 implants (α=.05). The mean vertical displacements were statistically higher than the mean displacements in the mesiodistal and buccolingual directions for both implants

  13. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  14. Neutron-induced displacement damage analysis (with particular reference to zirconium)

    International Nuclear Information System (INIS)

    Woo, C.H.

    1978-10-01

    Neutron irradiation produces damage in a solid, initially in the form of atomic displacements. As a first step to understanding the effects of irradiation damage in reactor structural materials, information on the initial atomic displacements is necessary. The computer program DISPKAN, based on an extension and generalization of the program RICE, written at ORNL for such calculations, has been developed and installed on the CDC system at CRNL. Using neutron scattering data from ENDF/B files, DISPKAN performs a displacement and PKO analysis on the initial damage caused by neutrons from a given spectrum. The following quantities are calculated: the displacement rate per unit neutron flux, the PKO spectrum, the displacement spectrum, the fraction of PKO's with energy above T, the fraction of displacements produced by PKO's with energy above T, the average PKO energy, the average number of displacements produced per PKO, and the total number of PKO's produced per atom of the solid per unit fluence. The input and output formats of the program are explained. Sample runs are demonstrated. Results for zirconium, exposed to five neutron spectra typically available to experimentalist, are given to illustrate the spectral dependence of the initial displacement events. (author)

  15. High-precision coseismic displacement estimation with a single-frequency GPS receiver

    Science.gov (United States)

    Guo, Bofeng; Zhang, Xiaohong; Ren, Xiaodong; Li, Xingxing

    2015-07-01

    To improve the performance of Global Positioning System (GPS) in the earthquake/tsunami early warning and rapid response applications, minimizing the blind zone and increasing the stability and accuracy of both the rapid source and rupture inversion, the density of existing GPS networks must be increased in the areas at risk. For economic reasons, low-cost single-frequency receivers would be preferable to make the sparse dual-frequency GPS networks denser. When using single-frequency GPS receivers, the main problem that must be solved is the ionospheric delay, which is a critical factor when determining accurate coseismic displacements. In this study, we introduce a modified Satellite-specific Epoch-differenced Ionospheric Delay (MSEID) model to compensate for the effect of ionospheric error on single-frequency GPS receivers. In the MSEID model, the time-differenced ionospheric delays observed from a regional dual-frequency GPS network to a common satellite are fitted to a plane rather than part of a sphere, and the parameters of this plane are determined by using the coordinates of the stations. When the parameters are known, time-differenced ionospheric delays for a single-frequency GPS receiver could be derived from the observations of those dual-frequency receivers. Using these ionospheric delay corrections, coseismic displacements of a single-frequency GPS receiver can be accurately calculated based on time-differenced carrier-phase measurements in real time. The performance of the proposed approach is validated using 5 Hz GPS data collected during the 2012 Nicoya Peninsula Earthquake (Mw 7.6, 2012 September 5) in Costa Rica. This shows that the proposed approach improves the accuracy of the displacement of a single-frequency GPS station, and coseismic displacements with an accuracy of a few centimetres are achieved over a 10-min interval.

  16. Diagnosing displaced four-part fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig; Bagger, Jens; Sylvest, Annette

    2009-01-01

    Displaced four-part fractures comprise 2-10 % of all proximal humeral fractures. The optimal treatment is unclear and randomised trials are needed. The conduct and interpretation of such trials is facilitated by a reproducible fracture classification. We aimed at quantifying observer agreement...... on the classification of displaced four-part fractures according to the Neer system. Published and unpublished data from five observer studies were reviewed. Observers agreed less on displaced four-part fractures than on the overall Neer classification. Mean kappa values for interobserver agreement ranged from 0.......16 to 0.48. Specialists agreed slightly more than fellows and residents. Advanced imaging modalities (CT and 3D CT) seemed to contribute more to classification of displaced four-part patterns than in less complex fracture patterns. Low observer agreement may challenge the clinical approach to displaced...

  17. Land Restitution and Prevention of Forced Displacement in Colombia

    Directory of Open Access Journals (Sweden)

    Felipe Gómez-Isa

    2010-11-01

    Full Text Available The armed conflict in Colombia, which has generated over three million internally displaced persons, has dramatic humanitarian consequences and raises serious issues regarding the protection of displaced peoples’ rights. The underlying reasons for the displacement often lie in the dynamics associated with territorial control and land seizures undertaken for strategic, military or purely economic purposes. Domestic and international legal provisions have established the victims’ right to the restitution of their homes and property as the “preferred remedy” in cases of displacement. However, policies dealing with displacement, both those of the Colombian government and of several international institutions, fail to take this sufficiently into account. A comprehensive reparation policy for victims must necessarily entail the reversion of lands, territories and goods seized in Colombia under the pretext of the internal armed conflict.

  18. Method of making self-calibrated displacement measurements

    International Nuclear Information System (INIS)

    Pedersen, H.N.

    1977-01-01

    A method for monitoring the displacement of an object having an acoustically reflective surface at least partially submerged in an acoustically conductive medium is described. The reflective surface is designed to have a stepped interface responsive to an incident acoustic pulse to provide separate discrete reflected pulses to a receiving transducer. The difference in the time of flight of the reflected acoustic signals corresponds to the known step height and the time of travel of the signals to the receiving transducer provides a measure of the displacement of the object. Accordingly, the reference step length enables simultaneous calibration of each displacement measurement. 3 claims, 3 figures

  19. Mental health of internally displaced persons in Jalozai camp, Pakistan.

    Science.gov (United States)

    Mujeeb, Arooj

    2015-11-01

    Internal displacement has been a distressing issue of Pakistan for last one decade. Few research works have been conducted on the psychological issues of internally displaced persons in Pakistan. The current research was aimed at determining the psychological effects of internal displacement, that is, psychological well-being, depression, anxiety and stress (internalizing problems) of the individuals who were displaced as a result of an armed conflict in Swat. A sample of 126 internally displaced persons was taken from Jalozai camp which included females (n = 65) and males (n = 61). Age of the sample ranged from 20 to 75 years with a mean of 47.5 years. Translated and adapted versions of Well-Being Affectometer-2 Scale and Depression Anxiety Stress Scale were used in the current research. Results of the study indicated differences between males and females, females being higher on internalizing problems and lower on psychological well-being, whereas family loss during displacement affected the results in the same way. Well-being, gender and family loss emerged as significant predictors of internalizing problems, and gender moderated the relationship between well-being and internalizing problems. Internal displacement may bring psychological issues for internally displaced persons, that is, their well-being may decrease and depression, anxiety and stress may increase during displacement. Limitations and implications of the study were discussed further. © The Author(s) 2015.

  20. ANALYTICAL CALCULATION OF THE BASIC ELECTROMAGNETIC LOSSES OF THE ENERGY OF THE FREQUENCY-REGULATED ASYNCHRONOUS ENGINE IN POSITIONING

    Directory of Open Access Journals (Sweden)

    V. O. Volkov

    2018-02-01

    Full Text Available Purpose. Obtaining analytical dependencies for the calculation of the main electromagnetic energy losses of a frequency-controlled induction motor in positioning modes with small displacements for various types (linear, parabolic and quasi-optimal of its velocity variation. Methodology. Similarity methods, differential and integral calculus, analytical interpolation, mathematical analysis. Findings. Analytical dependencies for calculation of current electromagnetic power losses and basic electromagnetic energy losses of a frequency-controlled asynchronous motor in the modes of positioning with small displacements for various types (linear, parabolic and quasi-optimal of its velocity are obtained. A universal form of the analytical dependence for calculating the optimal acceleration and deceleration times for a frequency-controlled asynchronous motor for positioning with small displacements, corresponding to minimization of the main electromagnetic energy losses of this engine with the indicated positioning for various species (linear, parabolic and quasi-optimal, is obtained. A comparative quantitative assessment of the change is made: the optimum values of the main electromagnetic energy losses of the frequency-controlled asynchronous engine and the corresponding maximum speed and optimal acceleration and deceleration times, in the function of the set prescribed small displacements for the various engine speed trajectories under consideration. Originality. For the first time, analytical dependencies for the calculation of the main electromagnetic energy losses of a frequency-controlled asynchronous motor are obtained for positioning with small displacements as a function of the set values of the movement of the motor shaft and the set values of its acceleration and deceleration times for the specified specified displacements. For the first time, dependences are obtained for a quantitative estimate of the minimum fundamental electromagnetic

  1. Three dimensional boundary displacement due to stable ideal kink modes excited by external n = 2 magnetic perturbations

    Science.gov (United States)

    Willensdorfer, M.; Strumberger, E.; Suttrop, W.; Dunne, M.; Fischer, R.; Birkenmeier, G.; Brida, D.; Cavedon, M.; Denk, S. S.; Igochine, V.; Giannone, L.; Kirk, A.; Kirschner, J.; Medvedeva, A.; Odstrčil, T.; Ryan, D. A.; The ASDEX Upgrade Team; The EUROfusion MST1 Team

    2017-11-01

    In low-collisionality (ν\\star) scenarios exhibiting mitigation of edge localized mode (ELMs), stable ideal kink modes at the edge are excited by externally applied magnetic perturbation (MP)-fields. In ASDEX Upgrade these modes can cause three-dimensional (3D) boundary displacements up to the centimeter range. These displacements have been measured using toroidally localized high resolution diagnostics and rigidly rotating n=2 MP-fields with various applied poloidal mode spectra. These measurements are compared to non-linear 3D ideal magnetohydrodynamics (MHD) equilibria calculated by VMEC. Comprehensive comparisons have been conducted, which consider for instance plasma movements due to the position control system, attenuation due to internal conductors and changes in the edge pressure profiles. VMEC accurately reproduces the amplitude of the displacement and its dependencies on the applied poloidal mode spectra. Quantitative agreement is found around the low field side (LFS) midplane. The response at the plasma top is qualitatively compared. The measured and predicted displacements at the plasma top maximize when the applied spectra is optimized for ELM-mitigation. The predictions from the vacuum modeling generally fails to describe the displacement at the LFS midplane as well as at the plasma top. When the applied mode spectra is set to maximize the displacement, VMEC and the measurements clearly surpass the predictions from the vacuum modeling by a factor of four. Minor disagreements between VMEC and the measurements are discussed. This study underlines the importance of the stable ideal kink modes at the edge for the 3D boundary displacement in scenarios relevant for ELM-mitigation.

  2. [Displacement of the posterior part of the eyeball in myopia].

    Science.gov (United States)

    Akizawa, Yasuko; Masahiro, Ida

    2006-12-01

    The principal aim of this study was to investigate displacement of the posterior part of the eyeball within the muscle cone in myopic eyes, particularly in moderately myopic subjects as well as in high myopes. Secondly, the correlation of the amount of displacement and the outer axial length of the globe was studied. The direction of displacement was also examined to clarify whether the eyeball tends to shift toward a certain direction. Seven patients with moderate myopia (moderate myopia group), fifteen patients with high myopia without esotropia (high myopia group), five patients with high myopia and esotropia (myopic esotropia group), and twenty-two controls (control group) were examined. Using magnetic resonance imaging, the outer axial length and the displacement of the posterior portion of the eyeball in the muscle cone were measured. In order to eliminate interindividual differences in the facial configuration, the coronal scanning was done perpendicularly to the orbital axis. The displacement was measured in a plane 4 mm anterior to the globe-optic nerve junction. The displacement was represented by the distance and direction of the globe center from the center of the muscle cone. In the moderate myopia group, there was no displacement of the posterior part of the eyeball in the muscle cone. It was the same as in the control group. But among the three groups, the displacement (mean standard deviation) was significantly greater in the myopic esotropia group (1.53 +/- 0.49 mm) and the high myopia group (0.94 +/- 0.52 mm) than in the control group (0.11 +/- 0.18 mm) (one way ANOVA and multiple comparison). The outer axial length and the distance of the displacement in all cases was significantly correlated (r = 0.87, p = 0.01). Moreover, the posterior part of the eyeball of the myopic esotropia group and the high myopia group was displaced superiorly and temporally. The posterior part of the eyeball of myopic eyes was displaced superotemporally in the muscle

  3. Quantification of the vocal folds’ dynamic displacements

    Science.gov (United States)

    del Socorro Hernández-Montes, María; Muñoz, Silvino; De La Torre, Manuel; Flores, Mauricio; Pérez, Carlos; Mendoza-Santoyo, Fernando

    2016-05-01

    Fast dynamic data acquisition techniques are required to investigate the motional behavior of the vocal folds (VFs) when they are subjected to a steady air-flow through the trachea. High-speed digital holographic interferometry (DHI) is a non-invasive full-field-of-view technique that has proved its usefulness to study rapid and non-repetitive object movements. Hence it is an ideal technique used here to measure VF displacements and vibration patterns at 2000 fps. Analyses from a set of 200 displacement images showed that VFs’ vibration cycles are established along their width (y) and length (x). Furthermore, the maximum deformation for the right and left VFs’ area may be quantified from these images, which in itself represents an important result in the characterization of this structure. At a controlled air pressure, VF displacements fall within the range ~100-1740 nm, with a calculated precision and accuracy that yields a variation coefficient of 1.91%. High-speed acquisition of full-field images of VFs and their displacement quantification are on their own significant data in the study of their functional and physiological behavior since voice quality and production depend on how they vibrate, i.e. their displacement amplitude and frequency. Additionally, the use of high speed DHI avoids prolonged examinations and represents a significant scientific and technological alternative contribution in advancing the knowledge and working mechanisms of these tissues.

  4. Assessment of quality of life of patients who underwent anterior cruciate ligament reconstruction and a rehabilitation program

    Directory of Open Access Journals (Sweden)

    Moises Cohen

    2004-12-01

    Full Text Available Introduction: Quality of life can be defined as the expression of aconceptual model that tries to represent patient’s perspectivesand his/her level of satisfaction expressed by numbers. Theobjective of this study is to evaluate the parameters of quality oflife of 23 patients who underwent surgery for anterior cruciateligament reconstruction. Methods: We adopted SF-36, a generichealth-related evaluation questionnaire, to obtain informationregarding several aspects of patients’ health conditions, and theLysholm questionnaire, specific to evaluate the symptoms andfunction of the knee. The questionnaires were applied at two stagesof the treatment: pre- and postoperatively (after the rehabilitationprogram. Results: Before surgery, the Lysholm questionnairepresented the following results: excellent in 4% of the cases, goodin 22%, fair in 22%, and poor in 52%. After surgery (Lysholm e SF-36 the correlation level was approximately 44% (p = 0.041.Discussion: The correlation between the Lysholm and the SF-36questionnaires showed the following: the lower the level of pain,the higher the Lysholm score. The high scores presented by theLysholm questionnaire are directly proportional to physical andemotional aspects, and to functional capacity. Conclusion:Analysis of both questionnaires, as well as of their correlation,showed some improvement in patients´ quality of life. We werealso able to demonstrate the importance and usefulness of applyingthe two questionnaires at three different moments: before, duringand after physiotherapeutic intervention.

  5. Lateral vibration analysis of continuous bridges utilizing equal displacement rule

    Directory of Open Access Journals (Sweden)

    Biao Wei

    Full Text Available The application of equal displacement rule simplifies the evaluation of lateral displacement demand forSDOF system. For complex multi-degree-of-freedom (MDOF structures such as continuous bridge systems, however, it requires more investigations. In this paper, a comprehensive parametric study of the ratio of maximum inelastic displacement to maximum elastic displacement for typical continuous bridges is performedto advance the application of equal displacement rule to MDOF systems. Particurlarly for the bridges with long periods, this adapted methodlogy is further simplified. It is concluded that equal displacement rule of MDOF is applicable to continuous bridges when the periods of the main modes are no less than the limiting period, which usually serves as an indication to the level of inelastic deformation for a bridge subjected to an earthquake.

  6. Myocardial strains from 3D displacement encoded magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Kindberg Katarina

    2012-04-01

    Full Text Available Abstract Background The ability to measure and quantify myocardial motion and deformation provides a useful tool to assist in the diagnosis, prognosis and management of heart disease. The recent development of magnetic resonance imaging methods, such as harmonic phase analysis of tagging and displacement encoding with stimulated echoes (DENSE, make detailed non-invasive 3D kinematic analyses of human myocardium possible in the clinic and for research purposes. A robust analysis method is required, however. Methods We propose to estimate strain using a polynomial function which produces local models of the displacement field obtained with DENSE. Given a specific polynomial order, the model is obtained as the least squares fit of the acquired displacement field. These local models are subsequently used to produce estimates of the full strain tensor. Results The proposed method is evaluated on a numerical phantom as well as in vivo on a healthy human heart. The evaluation showed that the proposed method produced accurate results and showed low sensitivity to noise in the numerical phantom. The method was also demonstrated in vivo by assessment of the full strain tensor and to resolve transmural strain variations. Conclusions Strain estimation within a 3D myocardial volume based on polynomial functions yields accurate and robust results when validated on an analytical model. The polynomial field is capable of resolving the measured material positions from the in vivo data, and the obtained in vivo strains values agree with previously reported myocardial strains in normal human hearts.

  7. Monitoring of Bridges by a Laser Pointer: Dynamic Measurement of Support Rotations and Elastic Line Displacements: Methodology and First Test.

    Science.gov (United States)

    Artese, Serena; Achilli, Vladimiro; Zinno, Raffaele

    2018-01-25

    Deck inclination and vertical displacements are among the most important technical parameters to evaluate the health status of a bridge and to verify its bearing capacity. Several methods, both conventional and innovative, are used for structural rotations and displacement monitoring; however, none of these allow, at the same time, precision, automation, static and dynamic monitoring without using high cost instrumentation. The proposed system uses a common laser pointer and image processing. The elastic line inclination is measured by analyzing the single frames of an HD video of the laser beam imprint projected on a flat target. For the image processing, a code was developed in Matlab ® that provides instantaneous rotation and displacement of a bridge, charged by a mobile load. An important feature is the synchronization of the load positioning, obtained by a GNSS receiver or by a video. After the calibration procedures, a test was carried out during the movements of a heavy truck maneuvering on a bridge. Data acquisition synchronization allowed us to relate the position of the truck on the deck to inclination and displacements. The inclination of the elastic line at the support was obtained with a precision of 0.01 mrad. The results demonstrate the suitability of the method for dynamic load tests, and the control and monitoring of bridges.

  8. Monitoring of Bridges by a Laser Pointer: Dynamic Measurement of Support Rotations and Elastic Line Displacements: Methodology and First Test

    Directory of Open Access Journals (Sweden)

    Serena Artese

    2018-01-01

    Full Text Available Deck inclination and vertical displacements are among the most important technical parameters to evaluate the health status of a bridge and to verify its bearing capacity. Several methods, both conventional and innovative, are used for structural rotations and displacement monitoring; however, none of these allow, at the same time, precision, automation, static and dynamic monitoring without using high cost instrumentation. The proposed system uses a common laser pointer and image processing. The elastic line inclination is measured by analyzing the single frames of an HD video of the laser beam imprint projected on a flat target. For the image processing, a code was developed in Matlab® that provides instantaneous rotation and displacement of a bridge, charged by a mobile load. An important feature is the synchronization of the load positioning, obtained by a GNSS receiver or by a video. After the calibration procedures, a test was carried out during the movements of a heavy truck maneuvering on a bridge. Data acquisition synchronization allowed us to relate the position of the truck on the deck to inclination and displacements. The inclination of the elastic line at the support was obtained with a precision of 0.01 mrad. The results demonstrate the suitability of the method for dynamic load tests, and the control and monitoring of bridges.

  9. Large scale chromatographic separations using continuous displacement chromatography (CDC)

    International Nuclear Information System (INIS)

    Taniguchi, V.T.; Doty, A.W.; Byers, C.H.

    1988-01-01

    A process for large scale chromatographic separations using a continuous chromatography technique is described. The process combines the advantages of large scale batch fixed column displacement chromatography with conventional analytical or elution continuous annular chromatography (CAC) to enable large scale displacement chromatography to be performed on a continuous basis (CDC). Such large scale, continuous displacement chromatography separations have not been reported in the literature. The process is demonstrated with the ion exchange separation of a binary lanthanide (Nd/Pr) mixture. The process is, however, applicable to any displacement chromatography separation that can be performed using conventional batch, fixed column chromatography

  10. Effect of excavation method on rock mass displacement

    International Nuclear Information System (INIS)

    Sato, Toshinori; Kikuchi, Tadashi; Sugihara, Kozo

    1998-01-01

    Rock mass displacement measurements have been performed to understand rock mass behavior and its dependence on excavation method during drift excavation at the Tono mine. Rock mass displacements of 1.46 mm and 0.67 mm have been measured at one meter (0.33D: blasting, 0.42D: machine, D: width of drift) from the walls of drifts excavated by the drill and blasting method and machine, respectively. Numerical analysis of rock mass displacements with Finite Element Method has been performed assuming an excavation disturbed zone. Measured and analysed rock mass displacements are consistent with each other for the drift excavation by the drill and blasting method. The excavation disturbed zone was narrower for the drift excavated by machine than for the drift excavated by the drill and blasting method. (author)

  11. The representitativeness of patient position during the first treatment fractions

    DEFF Research Database (Denmark)

    Bertelsen, Anders; Nielsen, Morten; Westberg, Jonas

    2009-01-01

    BACKGROUND: During external radiotherapy daily or even weekly image verification of the patient position might be problematic due to the resulting workload. Therefore it has been customary to perform image verification only at the first treatment fraction. In this study it is investigated whether...... the patient position uncertainty at the initial three treatment fractions is representative for the uncertainty throughout the treatment course. METHODS: Seventy seven patients were treated using Elekta Synergy accelerators. The patients were immobilized during treatment by use of a customized VacFix bag...... and a mask of AquaPlast. Cone beam CT (CBCT) scans were performed at fractions 1, 2, and 3 and at the 10th and 20th treatment fractions. Displacements in patient position, translational and rotational, have been measured by an image registration of the CBCT and the planning CT scan. The displacements data...

  12. Pitot-probe displacement in a supersonic turbulent boundary layer

    Science.gov (United States)

    Allen, J. M.

    1972-01-01

    Eight circular pitot probes ranging in size from 2 to 70 percent of the boundary-layer thickness were tested to provide experimental probe displacement results in a two-dimensional turbulent boundary layer at a nominal free-stream Mach number of 2 and unit Reynolds number of 8 million per meter. The displacement obtained in the study was larger than that reported by previous investigators in either an incompressible turbulent boundary layer or a supersonic laminar boundary layer. The large probes indicated distorted Mach number profiles, probably due to separation. When the probes were small enough to cause no appreciable distortion, the displacement was constant over most of the boundary layer. The displacement in the near-wall region decreased to negative displacement in some cases. This near-wall region was found to extend to about one probe diameter from the test surface.

  13. Miscible fluid displacement: an answer to increasing oil recovery

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, N R; Rivera, R J

    1976-01-01

    This study presents the state of the art on miscible and miscible-type processes. It is well known that when these processes are applied under ideal laboratory conditions, the oil recovery obtained from linear cores approaches 100% of the total oil contained in the porous structure which is contacted by the displacing fluids. In the past few years, a worldwide shortage of crude oil supplies produced an increased interest in new oil recovery methods. Because of this situation, the oil industry turned its eyes back toward the miscible processes. This study discusses the following miscible fluid displacement processes: (1) high-pressure dry gas displacement; (2) enriched gas displacement; (3) GLP slug flooding; and (4) carbon dioxide displacement. In addition to the processes aforementioned, this work presents the main features of the micellar solution flooding process. (17 refs.)

  14. The Effect of Basepair Mismatch on DNA Strand Displacement.

    Science.gov (United States)

    Broadwater, D W Bo; Kim, Harold D

    2016-04-12

    DNA strand displacement is a key reaction in DNA homologous recombination and DNA mismatch repair and is also heavily utilized in DNA-based computation and locomotion. Despite its ubiquity in science and engineering, sequence-dependent effects of displacement kinetics have not been extensively characterized. Here, we measured toehold-mediated strand displacement kinetics using single-molecule fluorescence in the presence of a single basepair mismatch. The apparent displacement rate varied significantly when the mismatch was introduced in the invading DNA strand. The rate generally decreased as the mismatch in the invader was encountered earlier in displacement. Our data indicate that a single base pair mismatch in the invader stalls branch migration and displacement occurs via direct dissociation of the destabilized incumbent strand from the substrate strand. We combined both branch migration and direct dissociation into a model, which we term the concurrent displacement model, and used the first passage time approach to quantitatively explain the salient features of the observed relationship. We also introduce the concept of splitting probabilities to justify that the concurrent model can be simplified into a three-step sequential model in the presence of an invader mismatch. We expect our model to become a powerful tool to design DNA-based reaction schemes with broad functionality. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  15. Histone displacement during nucleotide excision repair

    DEFF Research Database (Denmark)

    Dinant, C.; Bartek, J.; Bekker-Jensen, S.

    2012-01-01

    Nucleotide excision repair (NER) is an important DNA repair mechanism required for cellular resistance against UV light and toxic chemicals such as those found in tobacco smoke. In living cells, NER efficiently detects and removes DNA lesions within the large nuclear macromolecular complex called...... of histone variants and histone displacement (including nucleosome sliding). Here we review current knowledge, and speculate about current unknowns, regarding those chromatin remodeling activities that physically displace histones before, during and after NER....

  16. Differences in the origins of kinetochore-positive and kinetochore-negative micronuclei: A live cell imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Erkang, E-mail: erkangj@ustc.edu.cn

    2016-05-15

    Highlights: • Most Kinetochore-negative micronuclei were derived from kinetochore-negative displaced chromosomes, kinetochore-negative lagging chromosomes and fragments of broken chromosome bridges in mitosis of MN-free cells. • Most Kinetochore-positive micronuclei were derived from kinetochore-positive displaced chromosomes, kinetochore-positive lagging chromosomes and fragments of broken chromosome bridges in mitosis of MN-free cells. • Kinetochore-positive lagging chromosomes developed into kinetochore-positive micronuclei at the higher frequency than kinetochore-positive displaced chromosomes, kinetochore-negative lagging chromosomes developed into kinetochore-negative micronuclei at the higher rate than kinetochore-negative displaced chromosomes and broken chromosome bridges produced K−MNi and/or K+MNi. - Abstract: Micronuclei (MNi) are extensively used to evaluate genotoxicity and chromosomal instability. Classification of kinetochore-negative (K−MNi) and kinetochore-positive micronuclei (K+MNi) improves the specificity and sensitivity of the micronucleus (MN) test; however, the fundamental differences in the origins of K−MNi and K+MNi have not been addressed due to the limitations of traditional methods. In the current study, HeLa CENP B-GFP H2B-mCherry cells were constructed in which histone 2B (H2B) and centromere protein B (CENP B) were expressed as fusion proteins to monomeric Cherry (mCherry) and EGFP, respectively. MNi were identified using H2B-mCherry; K+MN contained CENP B-GFP, while K−MN did not. Long-term live cell imaging was conducted to examine MN formation in the dual-color fluorescent HeLa cells. The results suggested that K−MNi were derived from kinetochore-negative displaced chromosomes (K−DCs), kinetochore-negative lagging chromosomes (K−LCs) and fragments of broken chromosome bridges (CBs) during late mitotic stages. The results also indicated that K+MNi are derived from kinetochore-positive displaced chromosomes (K

  17. Differences in the origins of kinetochore-positive and kinetochore-negative micronuclei: A live cell imaging study

    International Nuclear Information System (INIS)

    Jiang, Erkang

    2016-01-01

    Highlights: • Most Kinetochore-negative micronuclei were derived from kinetochore-negative displaced chromosomes, kinetochore-negative lagging chromosomes and fragments of broken chromosome bridges in mitosis of MN-free cells. • Most Kinetochore-positive micronuclei were derived from kinetochore-positive displaced chromosomes, kinetochore-positive lagging chromosomes and fragments of broken chromosome bridges in mitosis of MN-free cells. • Kinetochore-positive lagging chromosomes developed into kinetochore-positive micronuclei at the higher frequency than kinetochore-positive displaced chromosomes, kinetochore-negative lagging chromosomes developed into kinetochore-negative micronuclei at the higher rate than kinetochore-negative displaced chromosomes and broken chromosome bridges produced K−MNi and/or K+MNi. - Abstract: Micronuclei (MNi) are extensively used to evaluate genotoxicity and chromosomal instability. Classification of kinetochore-negative (K−MNi) and kinetochore-positive micronuclei (K+MNi) improves the specificity and sensitivity of the micronucleus (MN) test; however, the fundamental differences in the origins of K−MNi and K+MNi have not been addressed due to the limitations of traditional methods. In the current study, HeLa CENP B-GFP H2B-mCherry cells were constructed in which histone 2B (H2B) and centromere protein B (CENP B) were expressed as fusion proteins to monomeric Cherry (mCherry) and EGFP, respectively. MNi were identified using H2B-mCherry; K+MN contained CENP B-GFP, while K−MN did not. Long-term live cell imaging was conducted to examine MN formation in the dual-color fluorescent HeLa cells. The results suggested that K−MNi were derived from kinetochore-negative displaced chromosomes (K−DCs), kinetochore-negative lagging chromosomes (K−LCs) and fragments of broken chromosome bridges (CBs) during late mitotic stages. The results also indicated that K+MNi are derived from kinetochore-positive displaced chromosomes (K

  18. MR imaging of displaced meniscal tears of the knee. Importance of a 'disproportional posterior horn sign'

    International Nuclear Information System (INIS)

    Chen, H.C.; Hsu, C.Y.; Shih, T.T.F.; Huang, K.M.; Li, Y.W.

    2001-01-01

    Purpose: Meniscal tears associated with displaced fragments are clinically significant. We propose the 'disproportional posterior horn sign' as a supportive criterion to identify a posterocentrally displaced meniscal fragment on MR imaging studies. If the meniscal posterior horn in the central portion appears larger than that in the peripheral section, it is considered positive for 'disproportional posterior horn sign'. Material and Methods: MR images obtained in 42 patients with 43 lesions, confirmed to have displaced meniscal tears, were included in this study. The MR images were retrospectively evaluated for the presence of the 'disproportional posterior horn sign', as well as the other known signs. Results: The 'disproportional posterior horn sign' was seen in 9 (20.9%) of 43 lesions, including 1 lateral discoid meniscal tear, 5 lateral meniscal tears and 3 medial meniscal tears. Five of them also had other signs of a displaced meniscal fragment. However, the remaining 4 cases only exhibited the 'disproportional posterior horn sign'. For the other MR signs, the 'absent bow tie sign' was detected in 40 (93%) of 43 lesions, the 'flipped meniscus sign' in 27 (62.8%) of 43 lesions, the 'double posterior cruciate ligament sign' in 17 (39.5%) of 43 lesions and the 'notch fragment sign' in 22 (51.2%) of 43 lesions. Conclusion: The 'disproportional posterior horn sign' is helpful in demonstrating a posterocentrally displaced meniscal fragment, especially when other characteristic signs are unremarkable or absent

  19. Video Games, Adolescents, and the Displacement Effect

    Science.gov (United States)

    Fisher, Carla Christine

    2012-01-01

    The displacement effect (the idea that time spent in one activity displaces time spent in other activities) was examined within the lens of adolescents' video game use and their time spent reading, doing homework, in physically active sports and activities, in creative play, and with parents and friends. Data were drawn from the Panel Study…

  20. Temporomandibular joint - normal features and disc displacements: magnetic resonance imaging; Articulacao temporomandibular - aspectos normais e deslocamentos de disco: imagem por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Ana Carolina Araujo; Sarmento, Viviane Almeida; Campos, Paulo Sergio Flores; Gonzalez, Maria Olivia Dias [Bahia Univ., Salvador, BA (Brazil). Faculdade de Odontologia]. E-mail: ana_carolinaramos@hotmail.com

    2004-12-01

    Disc displacement of the temporomandibular joint has been defined as an abnormal relationship between the articular disc and the mandibular condyle, fossa and articular eminence. Disc displacements may occur without immediate interference in the function of the joint. Magnetic resonance imaging shows high diagnostic accuracy in the determination of articular disc position and has been indicated as the diagnostic method of choice for soft tissue abnormalities of the temporomandibular joint. The aim of this study is to review the literature including the normal features and different types of disc displacement of the temporomandibular joint as well as the imaging findings, emphasizing the role of magnetic resonance imaging. (author)

  1. Measuring displacement signal with an accelerometer

    International Nuclear Information System (INIS)

    Han, Sang Bo

    2010-01-01

    An effective and simple way to reconstruct displacement signal from a measured acceleration signal is proposed in this paper. To reconstruct displacement signal by means of double-integrating the time domain acceleration signal, the Nyquist frequency of the digital sampling of the acceleration signal should be much higher than the highest frequency component of the signal. On the other hand, to reconstruct displacement signal by taking the inverse Fourier transform, the magnitude of the significant frequency components of the Fourier transform of the acceleration signal should be greater than the 6 dB increment line along the frequency axis. With a predetermined resolution in time and frequency domain, determined by the sampling rate to measure and record the original signal, reconstructing high-frequency signals in the time domain and reconstructing low-frequency signals in the frequency domain will produce biased errors. Furthermore, because of the DC components inevitably included in the sampling process, low-frequency components of the signals are overestimated when displacement signals are reconstructed from the Fourier transform of the acceleration signal. The proposed method utilizes curve-fitting around the significant frequency components of the Fourier transform of the acceleration signal before it is inverse-Fourier transformed. Curve-fitting around the dominant frequency components provides much better results than simply ignoring the insignificant frequency components of the signal

  2. Overhead Transmission Lines Deicing under Different Incentive Displacement

    Directory of Open Access Journals (Sweden)

    Qing He

    2014-01-01

    Full Text Available Overhead transmission line icing is one of the main factors affecting safety and reliability of power grid. This paper proposed an excitation deicing method of iced wire and theoretically revealed the ice removal mechanism under displacement excitation conditions, by taking the LGJ-70/10 glaze icing wire as the 3D model and analyzing and studying its dynamic response under the effect of displacement excitation. The simulation results show that the stress of wire icing area is enlarged with the increase of excitation displacement and frequency. Through the comparison of the compression strength experimental results on a series of different iced wires in low temperature environment, the authors found out that the stress generated from the wire icing area is greater than the crushing strength of the ice within the scope of the calculation parameters, which proved the validity and the feasibility of the method, and finally the suitable excitation displacement is determined. Following studies show that, as far as possible, it is necessary to reduce the incentive displacement and also to select the appropriate constraint length in order to avoid the line jumping that may be caused by large span ice shedding.

  3. Particle displacement tracking for PIV

    Science.gov (United States)

    Wernet, Mark P.

    1990-01-01

    A new Particle Imaging Velocimetry (PIV) data acquisition and analysis system, which is an order of magnitude faster than any previously proposed system has been constructed and tested. The new Particle Displacement Tracing (PDT) system is an all electronic technique employing a video camera and a large memory buffer frame-grabber board. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine velocity vectors. Application of the PDT technique to a counter-rotating vortex flow produced over 1100 velocity vectors in 110 seconds when processed on an 80386 PC.

  4. Displacement of the posterior part of the eyeball in myopia

    International Nuclear Information System (INIS)

    Akizawa, Yasuko; Ida, Masahiro

    2006-01-01

    The principal aim of this study was to investigate displacement of the posterior part of the eyeball within the muscle cone in myopic eyes, particularly in moderately myopic subjects as well as in high myopes. Secondly, the correlation of the amount of displacement and the outer axial length of the globe was studied. The direction of displacement was also examined to clarify whether the eyeball tends to shift toward a certain direction. Seven patients with moderate myopia (moderate myopia group), fifteen patients with high myopia without esotropia (high myopia group), five patients with high myopia and esotropia (myopic esotropia group), and twenty-two controls (control group) were examined. Using magnetic resonance imaging, the outer axial length and the displacement of the posterior portion of the eyeball in the muscle cone were measured. In order to eliminate interindividual differences in the facial configuration, the coronal scanning was done perpendicularly to the orbital axis. The displacement was measured in a plane 4 mm anterior to the globe-optic nerve junction. The displacement was represented by the distance and direction of the globe center from the center of the muscle cone. In the moderate myopia group, there was no displacement of the posterior part of the eyeball in the muscle cone. It was the same as in the control group. But among the three groups, the displacement (mean±standard deviation) was significantly greater in the myopic esotropia group (1.53±0.49 mm) and the high myopia group (0.94±0.52 mm) than in the control group (0.11±0.18 mm) (one way ANOVA and multiple comparison). The outer axial length and the distance of the displacement in all cases was significantly correlated (r=0.87, p=0.01). Moreover, the posterior part of the eyeball of the myopic esotropia group and the high myopia group was displaced superiorly and temporally. The posterior part of the eyeball of myopic eyes was displaced superotemporally in the muscle cone

  5. The Banality of Displacement: Turning a (ColourBlind Eye on the Ethnic Representation of the Internally Displaced in Colombia

    Directory of Open Access Journals (Sweden)

    Ulrich Oslender

    2010-01-01

    Full Text Available Colombia has one of the highest numbers of internally displaced persons, or IDPs, world-wide. Yet, there exists a conundrum. While latest NGO figures put the total number of IDPs since 1985 at 4 million, Colombian government figures show much lower estimates of 1.9 million. In fact, there are significant discrepancies in the ways how IDPs are identified, counted and categorised. Moreover, whereas it is now commonly argued that displacement has affected black populations proportionately higher than mestizo populations, no data exists to sustain such a view. The displaced population has simply not been accounted for in terms of its ethnic composition. In this article, drawing on Hannah Arendt’s work on terror and evil, I propose the notion of the “banality of displacement” to explain such a colour-blind approach in the discourses and representation of displacement in Colombia. I will refer in particular to the case of the Afro-Colombian population, drawing on fieldwork data collected since 1996, when I begun to work with the social movement of black communities in Colombia

  6. Research regarding the influence of driving-wires length change on positioning precision of a robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    The paper emphasise positioning precision of an elephant's trunk robotic arm which has joints driven by wires with variable length while operating The considered 5 degrees of freedom robotic arm has a particular structure of joint that makes possible inner actuation with wire-driven mechanism. We analyse solely the length change of wires as a consequence due inner winding and unwinding on joints for certain values of rotational angles. Variations in wires length entail joint angular displacements. We analyse positioning precision by taking into consideration equations from inverse kinematics of the elephant's trunk robotic arm. The angular displacements of joints are considered into computational method after partial derivation of positioning equations. We obtain variations of wires length at about tenths of micrometers. These variations employ angular displacements which are about minutes of sexagesimal degree and, thus, define positioning precision of elephant's trunk robotic arms. The analytical method is used for determining aftermath design structure of an elephant's trunk robotic arm with inner actuation through wires on positioning precision. Thus, designers could take suitable decisions on accuracy specifications limits of the robotic arm.

  7. Quantification of the vocal folds’ dynamic displacements

    International Nuclear Information System (INIS)

    Hernández-Montes, María del Socorro; Muñoz, Silvino; De La Torre, Manuel; Flores, Mauricio; Pérez, Carlos; Mendoza-Santoyo, Fernando

    2016-01-01

    Fast dynamic data acquisition techniques are required to investigate the motional behavior of the vocal folds (VFs) when they are subjected to a steady air-flow through the trachea. High-speed digital holographic interferometry (DHI) is a non-invasive full-field-of-view technique that has proved its usefulness to study rapid and non-repetitive object movements. Hence it is an ideal technique used here to measure VF displacements and vibration patterns at 2000 fps. Analyses from a set of 200 displacement images showed that VFs’ vibration cycles are established along their width (y) and length (x). Furthermore, the maximum deformation for the right and left VFs’ area may be quantified from these images, which in itself represents an important result in the characterization of this structure. At a controlled air pressure, VF displacements fall within the range ∼100–1740 nm, with a calculated precision and accuracy that yields a variation coefficient of 1.91%. High-speed acquisition of full-field images of VFs and their displacement quantification are on their own significant data in the study of their functional and physiological behavior since voice quality and production depend on how they vibrate, i.e. their displacement amplitude and frequency. Additionally, the use of high speed DHI avoids prolonged examinations and represents a significant scientific and technological alternative contribution in advancing the knowledge and working mechanisms of these tissues. (paper)

  8. Backscattering position detection for photonic force microscopy

    International Nuclear Information System (INIS)

    Volpe, Giovanni; Kozyreff, Gregory; Petrov, Dmitri

    2007-01-01

    An optically trapped particle is an extremely sensitive probe for the measurement of pico- and femto-Newton forces between the particle and its environment in microscopic systems (photonic force microscopy). A typical setup comprises an optical trap, which holds the probe, and a position sensing system, which uses the scattering of a beam illuminating the probe. Usually the position is accurately determined by measuring the deflection of the forward-scattered light transmitted through the probe. However, geometrical constraints may prevent access to this side of the trap, forcing one to make use of the backscattered light instead. A theory is presented together with numerical results that describes the use of the backscattered light for position detection. With a Mie-Debye approach, we compute the total (incident plus scattered) field and follow its evolution as it is collected by the condenser lenses and projected onto the position detectors and the responses of position sensitive detectors and quadrant photodetectors to the displacement of the probe in the optical trap, both in forward and backward configurations. We find out that in the case of backward detection, for both types of detectors the displacement sensitivity can change sign as a function of the probe size and is null for some critical sizes. In addition, we study the influence of the numerical aperture of the detection system, polarization, and the cross talk between position measurements in orthogonal directions. We finally discuss how these features should be taken into account in experimental designs

  9. The importance of angiography in cases of growing and displacing processes in the adrenal glands

    International Nuclear Information System (INIS)

    Hauer, E.

    1981-01-01

    The objective of this investigation was to compare the distribution of the individual diagnoses concerning 45 patients angiographed with the diagnosis ''suspected growing and displacing process in the adrenal gland'' to the literature. The investigation also covered the question of whether the angiographic vessel patterns permitted to draw conclusions concerning the type of growing and displacing process. This group of 45 patients had been selected out of a collective of 101 patients who had been examined and whose angiographic diagnosis had been manifested either by an operation or by a resection. Finally, the most favourable diagnostic procedure in the various forms of tumours of the adrenal gland was discussed. The position of angiography in relation to sonography, scintiscanning, and computerized tomography was clarified. (orig./MG) [de

  10. The effect of multi-component adsorption on selectivity in ion exchange displacement systems.

    Science.gov (United States)

    Tugcu, N; Cramer, S M

    2005-01-21

    This paper examines chemically selective displacement chromatography using affinity ranking plots, batch displacer screening experiments, column displacements, multi-component adsorption isotherms and spectroscopy. The affinity ranking plot indicated that the displacers, sucrose octasulfate (SOS) and tatrazine, should possess sufficient affinity to displace the proteins amyloglucosidase and apoferritin over a wide range of operating conditions. In addition, the plots indicated that the separation of these proteins by displacement chromatography would be extremely difficult. Further, the two proteins were shown to have very similar retention times under shallow linear gradient conditions. When batch displacement experiments were carried out, both tartrazine and SOS exhibited significant selectivity differences with respect to their ability to displace these two proteins, in contrast to the affinity ranking plot results. Column displacement experiments carried out with sucrose octasulfate agreed with the predictions of the affinity ranking plots, with both proteins being displaced but poorly resolved under several column displacement conditions. On the other hand, column displacement with tartrazine as the displacer resulted in the selective displacement and partial purification of apoferritin. Single- and multi-component isotherms of the proteins with or without the presence of displacers were determined and were used to help explain the selectivity reversals observed in the column and batch displacement experiments. In addition, fluorescence and CD spectra suggested that the displacers did not induce any structural changes to either of the proteins. The results in this paper indicate that multi-component adsorption behavior can be exploited for creating chemically selective displacement separations.

  11. Earthquake damage to underground facilities and earthquake related displacement fields

    International Nuclear Information System (INIS)

    Pratt, H.R.; Stephenson, D.E.; Zandt, G.; Bouchon, M.; Hustrulid, W.A.

    1982-01-01

    The potential seismic risk for an underground facility is considered in the evaluation of its location and design. The possible damage resulting from either large-scale displacements or high accelerations should be considered in evaluating potential sites of underground facilities. Scattered through the available literature are statements to the effect that below a few hundred meters shaking and damage in mines is less than at the surface; however, data for decreased damage underground have not been completely reported or explained. In order to assess the seismic risk for an underground facility, a data base was established and analyzed to evaluate the potential for seismic disturbance. Substantial damage to underground facilities is usually the result of displacements primarily along pre-existing faults and fractures, or at the surface entrance to these facilities. Evidence of this comes from both earthquakes as a function of depth is important in the evaluation of the hazard to underground facilities. To evaluate potential displacements due to seismic effects of block motions along pre-existing or induced fractures, the displacement fields surrounding two types of faults were investigated. Analytical models were used to determine relative displacements of shafts and near-surface displacement of large rock masses. Numerical methods were used to determine the displacement fields associated with pure strike-slip and vertical normal faults. Results are presented as displacements for various fault lengths as a function of depth and distance. This provides input to determine potential displacements in terms of depth and distance for underground facilities, important for assessing potential sites and design parameters

  12. Studying Landslide Displacements in Megamendung (Indonesia Using GPS Survey Method

    Directory of Open Access Journals (Sweden)

    Hasanuddin Z. Abidin

    2004-11-01

    Full Text Available Landslide is one of prominent geohazards that frequently affects Indonesia, especially in the rainy season. It destroys not only environment and property, but usually also causes deaths. Landslide monitoring is therefore very crucial and should be continuously done. One of the methods that can have a contribution in studying landslide phenomena is repeated GPS survey method. This paper presents and discusses the operational performances, constraints and results of GPS surveys conducted in a well known landslide prone area in West Java (Indonesia, namely Megamendung, the hilly region close to Bogor. Three GPS surveys involving 8 GPS points have been conducted, namely on April 2002, May 2003 and May 2004, respectively. The estimated landslide displacements in the area are relatively quite large in the level of a few dm to a few m. Displacements up to about 2-3 m were detected in the April 2002 to May 2003 period, and up to about 3-4 dm in the May 2003 to May 2004 period. In both periods, landslides in general show the northwest direction of displacements. Displacements vary both spatially and temporally. This study also suggested that in order to conclude the existence of real and significant displacements of GPS points, the GPS estimated displacements should be subjected to three types of testing namely: the congruency test on spatial displacements, testing on the agreement between the horizontal distance changes with the predicted direction of landslide displacement, and testing on the consistency of displacement directions on two consecutive periods.

  13. Surface displacement imaging by interferometry with a light emitting diode

    International Nuclear Information System (INIS)

    Dilhaire, Stefan; Grauby, Stephane; Jorez, Sebastien; Lopez, Luis David Patino; Rampnoux, Jean-Michel; Claeys, Wilfrid

    2002-01-01

    We present an imaging technique to measure static surface displacements of electronic components. A device is supplied by a transient current that creates a variation of temperature, thus a surface displacement. To measure the latter, a setup that is based on a Michelson interferometer is used. To avoid the phenomenon of speckle and the drawbacks inherent to it, we use a light emitting diode as the light source for the interferometer. The detector is a visible CCD camera that analyzes the optical signal containing the information of surface displacement of the device. Combining images, we extract the amplitude of the surface displacement. Out-of-plane surface-displacement images of a thermoelectric device are presented

  14. Marginal greenhouse gas emissions displacement of wind power in Great Britain

    International Nuclear Information System (INIS)

    Thomson, R. Camilla; Harrison, Gareth P.; Chick, John P.

    2017-01-01

    There is considerable uncertainty over the effect of wind power on the operation of power systems, and the consequent greenhouse gas (GHG) emissions displacement; this is used to project emissions reductions that inform energy policy. Currently, it is approximated as the average emissions of the whole system, despite an acknowledgement that wind will actually displace only the generators operating on the margin. This article presents a methodology to isolate the marginal emissions displacement of wind power from historical empirical data, taking into account the impact on the operating efficiency of coal and CCGT plants. For Great Britain over 2009–2014, it was found that marginal emissions displacement has generally been underestimated with, for example, the emissions displacement factor for wind being 21% higher than that the average emissions factor in 2010. The actual displacement depends upon the relative merit of coal and CCGT, with a greater discrepancy between marginal displacement and average emissions during more normal system operation, suggesting that policies to penalise high-carbon generation can increase the effectiveness of wind at reducing GHG emissions. Furthermore, it was also identified that wind power is almost as technically effective as demand-side reductions at decreasing GHG emissions from power generation. - Highlights: • Marginal emissions displacement was calculated from operational data for 2009–2014. • Existing estimates of emissions displacement are generally low. • Emissions displacement is a function of the relative merit of coal and CCGT plants. • Policies to penalise high-carbon generation should increase emissions displacement. • Wind almost as effective as demand-reduction at reducing emissions.

  15. Characterizing absolute piezoelectric microelectromechanical system displacement using an atomic force microscope

    International Nuclear Information System (INIS)

    Evans, J.; Chapman, S.

    2014-01-01

    Piezoresponse Force Microscopy (PFM) is a popular tool for the study of ferroelectric and piezoelectric materials at the nanometer level. Progress in the development of piezoelectric MEMS fabrication is highlighting the need to characterize absolute displacement at the nanometer and Ångstrom scales, something Atomic Force Microscopy (AFM) might do but PFM cannot. Absolute displacement is measured by executing a polarization measurement of the ferroelectric or piezoelectric capacitor in question while monitoring the absolute vertical position of the sample surface with a stationary AFM cantilever. Two issues dominate the execution and precision of such a measurement: (1) the small amplitude of the electrical signal from the AFM at the Ångstrom level and (2) calibration of the AFM. The authors have developed a calibration routine and test technique for mitigating the two issues, making it possible to use an atomic force microscope to measure both the movement of a capacitor surface as well as the motion of a micro-machine structure actuated by that capacitor. The theory, procedures, pitfalls, and results of using an AFM for absolute piezoelectric measurement are provided

  16. Characterizing absolute piezoelectric microelectromechanical system displacement using an atomic force microscope

    Energy Technology Data Exchange (ETDEWEB)

    Evans, J., E-mail: radiant@ferrodevices.com; Chapman, S., E-mail: radiant@ferrodevices.com [Radiant Technologies, Inc., 2835C Pan American Fwy NE, Albuquerque, New Mexico 87107 (United States)

    2014-08-14

    Piezoresponse Force Microscopy (PFM) is a popular tool for the study of ferroelectric and piezoelectric materials at the nanometer level. Progress in the development of piezoelectric MEMS fabrication is highlighting the need to characterize absolute displacement at the nanometer and Ångstrom scales, something Atomic Force Microscopy (AFM) might do but PFM cannot. Absolute displacement is measured by executing a polarization measurement of the ferroelectric or piezoelectric capacitor in question while monitoring the absolute vertical position of the sample surface with a stationary AFM cantilever. Two issues dominate the execution and precision of such a measurement: (1) the small amplitude of the electrical signal from the AFM at the Ångstrom level and (2) calibration of the AFM. The authors have developed a calibration routine and test technique for mitigating the two issues, making it possible to use an atomic force microscope to measure both the movement of a capacitor surface as well as the motion of a micro-machine structure actuated by that capacitor. The theory, procedures, pitfalls, and results of using an AFM for absolute piezoelectric measurement are provided.

  17. Toward a Positive Explanation of Student Differences in Reading Growth

    Science.gov (United States)

    Adams, Curt M.; Palmer, Anna H.

    2017-01-01

    Background: Education has much in common with professions that are using positive psychology and positive organizational scholarship to transform practice, yet the science behind peak human and group functioning has been slow to displace deficit-based framing of reform policies and improvement strategies in education. Purpose of the Study: This…

  18. Radiation displacement damage estimates for a radionuclide waste stabilization material

    International Nuclear Information System (INIS)

    Dolan, K.W.

    1977-01-01

    Estimates of the number of atomic displacements produced in pollucite by the radioactive decay of Cs-134 are made. Pollucite is a candidate material for radionuclide waste stabilization, while Cs-134 is one of the radionuclide products which would be chemically bound in the pollucite lattice. At the maximum concentration of Cs-134 in pollucite, assuming a threshold displacement energy of 15.0 eV, the displacement rate is estimated to be 4.3 x 10 12 atoms/cm 3 /second which includes all atomic species in the pollucite lattice. It was found that most of the displacements, 85 percent, were caused by elastic scattering of photoelectrons and Compton electrons which are products of γ-ray interactions in the material. Most of the remaining displacements are caused by elastic scattering of β-particles. Recoil energies of the Ba daughter product are insufficient to cause displacement. Atomic displacements of nearest neighbors, atoms within one lattice spacing of the decay site, are estimated to be 2.7 x 10 6 atoms/cm 3 /second. These estimates provide a starting point for assessing the long term stability of pollucite to radiation damage

  19. [Management of disk displacement with condylar fracture].

    Science.gov (United States)

    Yu, Shi-bin; Li, Zu-bing; Yang, Xue-wen; Zhao, Ji-hong; Dong, Yao-jun

    2003-07-01

    To investigate clinical features of disk displacement during the course of condylar fracture and to explore the techniques of disk reposition and suturation. 32 patients (10 females and 22 males) who had disk displacements with condylar fractures were followed up. Reduction and reposition of the dislocated disks simultaneously with fixation of fractures were performed. 7 patients underwent intermaxillary fixation with elastic bands for 1 to 2 weeks. The occlusions were satisfactory in all cases but one for the reason of ramus height loss. No TMJ symptom was found when examined 3 months post operation. Anterior disk displacements were most occurred with high condylar process fractures. Surgical reposition and suturation of disk play an important role for the later TMJ-function.

  20. Monitoring of pipe displacements in French LMFBR SUPERPHENIX

    International Nuclear Information System (INIS)

    Foucher, N.; Debaene, J.P.; Renault, Y.; Blin, B.

    1993-01-01

    In order to check that pipe supports work properly and that the locking of snubbers or the loss of supports do not put a pipe in unacceptable loading conditions, a monitoring of the behaviour of the main pipes of SUPERPHENIX is planned. This monitoring system consists in measuring the displacements at selected points of the pipe by means of measuring rods and checking that these displacements remain inside allowable domains. These allowable domains are defined so that, if the displacements of the pipe are inside all these domains, the plant operator is sure that the stresses verify the allowable limits and then no additional inspection is carried out. In the opposite case, the operator will inspect the pipe in detail in order to determine the consequences and repair if necessary before restarting. Selection of points for monitoring was done with the to minimize the number of measures to be carried out and to use as far as possible the measuring rods that were installed to check that pipe displacements were consistent with what has been obtained in design calculations. However, it appears necessary to ensure that any incident occurring at any point of the pipe can be detected and, if necessary, additional measuring rods may be installed. An incident is said detectable if it induces on at least one measuring rod a deviation with respect to expected displacement not lower than 5 mm. It has been chosen so that small normal changes in measured displacements are not mistaken as incidents. The incidents that are supposed likely to occur are: 1) loss of a support which induces mainly primary stresses, 2) locking of a snubber which induces mainly secondary stresses. Monitoring of pipe displacements is a simple and effective way of checking that no damaging perturbation has occurred on the pipe. Calculations carried out on the DHR loops of SUPERPHENIX show that allowable domains of acceptable size may be obtained using a relatively small number of measuring rods. The method

  1. Sieve-based lateral displacement technology for suspension separation

    NARCIS (Netherlands)

    Dijkshoorn, J.P.; Wagterveld, R.M.; Boom, R.M.; Schutyser, M.A.I.

    2017-01-01

    Sparse lateral displacement arrays are easier to scale up than full deterministic lateral displacement arrays or deterministic ratchets, because they require lower pressure drop and simplify the construction of the device. However, the asymmetry of sparse arrays leads to a non-homogeneous pressure

  2. 100 group displacement cross sections from RECOIL data base

    International Nuclear Information System (INIS)

    Gopalakrishnan, V.

    1995-01-01

    Displacement cross sections in 100 neutron energy groups were calculated from the RECOIL data base using the RECOIL program, for use in DPA (Displacement Per Atom) calculations for FBTR and PFBR materials. 100 group displacement cross sections were calculated using RECOIL-Data Base and RECOIL Program. Modifications were made in the data base to reduce space requirement, and in the program for easy handling on a PC. 2 refs

  3. MRI anatomy of anteriorly displaced anus: what obstructs defecation?

    International Nuclear Information System (INIS)

    AbouZeid, Amr Abdelhamid; Mohammad, Shaimaa Abdelsattar; Khairy, Khaled Talaat

    2014-01-01

    Anteriorly displaced anus is an anomaly that is debated with regard to its nomenclature, diagnosis and management. To describe MRI anatomy of the anal canal in children with anteriorly displaced anus and its impact on the process of defecation. We prospectively examined ten children (7 girls, 3 boys; age range 7 months to 8 years, mean 3 years) with anteriorly displaced anus between August 2009 and April 2012. Noncontrast MRI examinations were performed on a 1.5-T magnet. T1- and T2-weighted turbo spin-echo images were acquired in axial, sagittal and coronal planes of the pelvis. The anorectal angle and the relative hiatal distance were measured in mid-sagittal images, and compared with those of a control group using the Mann-Whitney test. In children with anteriorly displaced anus, no anatomical abnormality was depicted at the level of the proximal anal canal. However, the distal anal canal was displaced anteriorly, running out its external muscle cuff, which remained un-displaced at the usual site of the anus. This changes the orientation of the central axis of the anal canal by passing across instead of along the fibers of the longitudinal muscle coat. Children with anteriorly displaced anus had a more obtuse anorectal angle (mean 112.1 ), which was significantly greater than that of the control group (mean 86.2 ). MRI is a valuable tool in studying the anatomy of the anal canal in children with anteriorly displaced anus. The abnormal orientation of the longitudinal muscle across the anal canal can explain the obstructed defecation in these children. Based on this study, it might be of interest to use MRI in studying equivocal cases and children with unexplained constipation. (orig.)

  4. MRI anatomy of anteriorly displaced anus: what obstructs defecation?

    Energy Technology Data Exchange (ETDEWEB)

    AbouZeid, Amr Abdelhamid [Ain-Shams University, Department of Pediatric Surgery, Cairo (Egypt); Mohammad, Shaimaa Abdelsattar; Khairy, Khaled Talaat [Ain-Shams University, Department of Radiodiagnosis, Cairo (Egypt)

    2014-07-15

    Anteriorly displaced anus is an anomaly that is debated with regard to its nomenclature, diagnosis and management. To describe MRI anatomy of the anal canal in children with anteriorly displaced anus and its impact on the process of defecation. We prospectively examined ten children (7 girls, 3 boys; age range 7 months to 8 years, mean 3 years) with anteriorly displaced anus between August 2009 and April 2012. Noncontrast MRI examinations were performed on a 1.5-T magnet. T1- and T2-weighted turbo spin-echo images were acquired in axial, sagittal and coronal planes of the pelvis. The anorectal angle and the relative hiatal distance were measured in mid-sagittal images, and compared with those of a control group using the Mann-Whitney test. In children with anteriorly displaced anus, no anatomical abnormality was depicted at the level of the proximal anal canal. However, the distal anal canal was displaced anteriorly, running out its external muscle cuff, which remained un-displaced at the usual site of the anus. This changes the orientation of the central axis of the anal canal by passing across instead of along the fibers of the longitudinal muscle coat. Children with anteriorly displaced anus had a more obtuse anorectal angle (mean 112.1 ), which was significantly greater than that of the control group (mean 86.2 ). MRI is a valuable tool in studying the anatomy of the anal canal in children with anteriorly displaced anus. The abnormal orientation of the longitudinal muscle across the anal canal can explain the obstructed defecation in these children. Based on this study, it might be of interest to use MRI in studying equivocal cases and children with unexplained constipation. (orig.)

  5. Performance of displacement ventilation in practice

    DEFF Research Database (Denmark)

    Naidenov, K.; Pitchurov, G.; Langkilde, Gunnar

    2002-01-01

    This paper presents results of a field study in offices with displacement ventilation. It comprises detailed physical measurements of the thermal environment and collection of occupants´ response at 227 workplaces. The results, both physical measurements and human response, identified draught...... as the major local discomfort in the rooms with displacement ventilation. Twenty-three percent of the occupants were daily bothered by draught. In some buildings the maintenance personnel tried to improve occupants´ thermal comfort by raising the supply air temperature or office workers themselves blocked...

  6. Distally displaced premolars: A dental anomaly associated with palatally displaced canines.

    Science.gov (United States)

    Baccetti, Tiziano; Leonardi, Maria; Giuntini, Veronica

    2010-09-01

    The aim of this study was to evaluate the significance of association between distally displaced premolars (DDP) and palatally displaced canines (PDC) in the pattern of associated phenotypes of dental developmental disturbance. A sample of 2811 subjects (mean age, 9 years 7 months +/- 1 year 3 months) was divided randomly into 2 groups. The first group of 500 subjects was the control group. The reference prevalence rates for the examined parameters were calculated for this group: DDP (measured with the distal angle theta and the premolar-molar angle gamma); PDC; and other dental anomalies, specifically, aplasia of the third molars, aplasia of the contralateral mandibular second premolar, aplasia of the maxillary lateral incisors, and small maxillary lateral incisors. Of the remaining 2311 subjects, the first 100 with a diagnosis of DDP of at least 1 mandibular second premolar comprised experimental group 1 (DDP group). In addition to sex distribution, the same variables that were examined in the control group were analyzed. In the subgroup with the concurrent DDP and PDC (experimental group 2, or DDP-PDC group), the presence of other dental anomalies was investigated. The prevalence rate for PDC in experimental group 1 was compared with that in the control group. The same was done for the prevalence rates for the 4 other dental anomalies in the PDC-DDP group (experimental group 2) vs the prevalence rates for these anomalies in the control group. All comparisons were performed with chi-square tests with the Yates correction (P <0.05), as were the comparisons between the sexes in experimental groups 1 and 2. The values for theta and gamma angles in experimental group 1 were compared with the values for these angles in experimental group 2, as well as with those in the control group. These statistical comparisons were made with analysis of variance (ANOVA) with the Bonferroni post-hoc test (P <0.05). The prevalence rate for PDC in experimental group 1 (28%) was

  7. Internal displacement and the Syrian crisis: an analysis of trends from 2011-2014.

    Science.gov (United States)

    Doocy, Shannon; Lyles, Emily; Delbiso, Tefera D; Robinson, Courtland W

    2015-01-01

    Since the start of the Syrian crisis in 2011, civil unrest and armed conflict in the country have resulted in a rapidly increasing number of people displaced both within and outside of Syria. Those displaced face immense challenges in meeting their basic needs. This study sought to characterize internal displacement in Syria, including trends in both time and place, and to provide insights on the association between displacement and selected measures of household well-being and humanitarian needs. This study presents findings from two complementary methods: a desk review of displaced population estimates and movements and a needs assessment of 3930 Syrian households affected by the crisis. The first method, a desk review of displaced population estimates and movements, provides a retrospective analysis of national trends in displacement from March 2011 through June 2014. The second method, analysis of findings from a 2014 needs assessment by displacement status, provides insight into the displaced population and the association between displacement and humanitarian needs. Findings indicate that while displacement often corresponds to conflict levels, such trends were not uniformly observed in governorate-level analysis. Governorate level IDP estimates do not provide information on a scale detailed enough to adequately plan humanitarian assistance. Furthermore, such estimates are often influenced by obstructed access to certain areas, unsubstantiated reports, and substantial discrepancies in reporting. Secondary displacement is not consistently reported across sources nor are additional details about displacement, including whether displaced individuals originated within the current governorate or outside of the governorate. More than half (56.4 %) of households reported being displaced more than once, with a majority displaced for more than one year (73.3 %). Some differences between displaced and non-displaced population were observed in residence crowding, food

  8. To the issue of the root of the matter of «internally displaced persons»: public policy and regional practice

    Directory of Open Access Journals (Sweden)

    I. M. Malykha

    2015-06-01

    The adoption of the Law of Ukraine «On protection of rights and freedoms of internally displaced persons» was a positive solution, however, it requires further work on implementation of the stated rules.

  9. Expansion of a function about a displaced centre

    International Nuclear Information System (INIS)

    Rashid, M.A.

    1981-07-01

    We review the progress recently made in obtaining closed form expressions for the expansion of general orbitals about a displaced centre and establish the equivalence between different expansions. We also examine how these expressions do have the desired limit as the displacement approaches zero. (author)

  10. Nanomechanical displacement sensing using a quantum point contact

    International Nuclear Information System (INIS)

    Cleland, A.N.; Aldridge, J.S.; Driscoll, D.C.; Gossard, A. C.

    2002-01-01

    We describe a radio frequency mechanical resonator that includes a quantum point contact, defined using electrostatic top gates. We can mechanically actuate the resonator using either electrostatic or magnetomotive forces. We demonstrate the use of the quantum point contact as a displacement sensor, operating as a radio frequency mixer at the mechanical resonance frequency of 1.5 MHz. We calculate a displacement sensitivity of about 3x10 -12 m/Hz 1/2 . This device will potentially permit quantum-limited displacement sensing of nanometer-scale resonators, allowing the quantum entanglement of the electronic and mechanical degrees of freedom of a nanoscale system

  11. Positioning devices for patients

    International Nuclear Information System (INIS)

    Heavens, M.

    1981-01-01

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  12. Fourier-based integration of quasi-periodic gait accelerations for drift-free displacement estimation using inertial sensors.

    Science.gov (United States)

    Sabatini, Angelo Maria; Ligorio, Gabriele; Mannini, Andrea

    2015-11-23

    In biomechanical studies Optical Motion Capture Systems (OMCS) are considered the gold standard for determining the orientation and the position (pose) of an object in a global reference frame. However, the use of OMCS can be difficult, which has prompted research on alternative sensing technologies, such as body-worn inertial sensors. We developed a drift-free method to estimate the three-dimensional (3D) displacement of a body part during cyclical motions using body-worn inertial sensors. We performed the Fourier analysis of the stride-by-stride estimates of the linear acceleration, which were obtained by transposing the specific forces measured by the tri-axial accelerometer into the global frame using a quaternion-based orientation estimation algorithm and detecting when each stride began using a gait-segmentation algorithm. The time integration was performed analytically using the Fourier series coefficients; the inverse Fourier series was then taken for reconstructing the displacement over each single stride. The displacement traces were concatenated and spline-interpolated to obtain the entire trace. The method was applied to estimate the motion of the lower trunk of healthy subjects that walked on a treadmill and it was validated using OMCS reference 3D displacement data; different approaches were tested for transposing the measured specific force into the global frame, segmenting the gait and performing time integration (numerically and analytically). The width of the limits of agreements were computed between each tested method and the OMCS reference method for each anatomical direction: Medio-Lateral (ML), VerTical (VT) and Antero-Posterior (AP); using the proposed method, it was observed that the vertical component of displacement (VT) was within ±4 mm (±1.96 standard deviation) of OMCS data and each component of horizontal displacement (ML and AP) was within ±9 mm of OMCS data. Fourier harmonic analysis was applied to model stride-by-stride linear

  13. Contact-type displacement measuring mechanism for fuel assembly in reactor

    International Nuclear Information System (INIS)

    Yokota, Yoshio; Ko, Kuniaki.

    1995-01-01

    The measuring mechanism of the present invention, which is used in a lmfbr type reactor, is suspended by a gripper of a fuel handing machine, and it comprises a combination of a displacement amount measuring jig allowed to be inserted into a handling head of a fuel assembly and a displacement amount measuring ring disposed at the lower portion in the handling head. The displacement amount measuring jig has a structure comprising a releasable handle and a columnar or cylindrical measuring portion allowable to be inserted into the handling head formed at the lower portion of the handle, which are connected with each other. When an interference (contact) occurred between the displacement amount measuring jig and the stepwise displacement amount measuring ring during the measurement, change of load and a phenomenon that the fuel handing machine can not be lowered are recognized, so that core displacement amount can be recognized based on the stroke of the gripper portion. Then, remote measurement is possible for displacement and deformation of the fuel assembly in the reactor container, and the measurement can be conducted by the same procedures and in the same period of time as in a case of ordinary fuel exchange operation. A flow channel for coolants passing through the fuel assembly can be ensured, thereby enabling to measure the amount of core displacement which is closer to an actual value in the reactor. (N.H.)

  14. Lateral displacement in small angle multiple scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bichsel, H.; Hanson, K.M.; Schillaci, K.M. (Los Alamos National Lab., NM (USA))

    1982-07-01

    Values have been calculated for the average lateral displacement in small angle multiple scattering of protons with energies of several hundred MeV. The calculations incorporate the Moliere distribution which does not make the gaussian approximations of the distribution in projected angle and lateral deflections. Compared to other published data, such approximations can lead to errors in the lateral displacement of up to 10% in water.

  15. Effect of Intraoperative Three-Dimensional Imaging During the Reduction and Fixation of Displaced Calcaneal Fractures on Articular Congruence and Implant Fixation

    DEFF Research Database (Denmark)

    Eckardt, Henrik; Lind, Marianne

    2015-01-01

    BACKGROUND: Operative treatment of displaced calcaneal fractures should restore joint congruence, but conventional fluoroscopy is unable to fully visualize the subtalar joint. We questioned whether intraoperative 3-dimensional (3D) imaging would aid in the reduction of calcaneal fractures......, resulting in improved articular congruence and implant positioning. METHOD: Sixty-two displaced calcaneal fractures were operated on using standard fluoroscopic views. When the surgeon had achieved a satisfactory reduction, an intraoperative 3D scan was conducted, malreductions or implant imperfections were...

  16. Studies on displacement behavior between hydrogen and deuterium in hydride column

    International Nuclear Information System (INIS)

    Lu Guangda; Li Gan; Jiang Guoqiang

    2001-01-01

    A series displacement experiments between hydrogen and deuterium in ZrCo, LaNi 5 , LaNi 4.7 Al 0.3 and Pd hydride column had been conducted at room temperature about. Results indicate that displacement characteristics related to factors such as temperature, gas flow rate, ratio surface area of solid phase and hydrogen isotope separation factor of the metal-hydrogen system. The palladium hydride have the best displacement characteristics, and LaNi 5 , LaNi 4.7 Al 0.3 and ZrCo are in the next places. Theoretical study reveals that the rule of the exchange reaction of hydrogen isotopes in gas-solid interface determines the displacement behavior and the displacing efficiency depends on exchange rate. The ideal stage mode could be used to describe the displacement breakthrough curve. The height equivalent to theoretical place (HETP) indicates the displacing effects. Also, the separation factor has a serious influence to HETP under the same condition

  17. HDR monotherapy for prostate cancer: A simulation study to determine the effect of catheter displacement on target coverage and normal tissue irradiation

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Roos, Martin A.; Aluwini, Shafak

    2011-01-01

    Purpose: The aim of this study was to systematically analyse the effect of catheter displacements both on target coverage and normal tissue irradiation in fractionated high dose rate (HDR) prostate brachytherapy, using a simulation study, and to define tolerances for catheter displacement ensuring that both target coverage and normal tissue doses remain clinically acceptable. Besides the effect of total implant displacement, also displacements of catheters belonging to selected template rows only were evaluated in terms of target coverage and normal tissue dose, in order to analyse the change in dose distribution as a function of catheter dwell weight and catheter location. Material and methods: Five representative implant geometries, with 17 catheters each, were selected. The clinical treatment plan was compared to treatment plans in which an entire implant displacement in caudal direction over 3, 5, 7 and 10 mm was simulated. Besides, treatment plans were simulated considering a displacement of either the central, most ventral or most dorsal catheter rows only, over 5 mm caudally. Results: Due to displacement of the entire implant the target coverage drops below the tolerance of 93% for all displacements studied. The effect of displacement of the entire implant on organs at risk strongly depended on the patient anatomy; e.g., for 80% of the implant geometries the V 80 of the rectum exceeded its tolerance for all displacements. The effect of displacement of catheters belonging to selected template rows depended strongly on the relative weight of each catheter row when considering the target coverage and on its location when considering the dose in the organs at risk. Conclusion: This study supports the need for a check of the catheter locations before each fraction and correction of deviations of the catheter position exceeding 3 mm.

  18. Test Rig for Valves of Digital Displacement Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Christensen, Jeppe Haals; Bech, Michael Møller

    2017-01-01

    A test rig for the valves of digital displacement machines has been developed at Aalborg University. It is composed of a commercial radial piston machine, which has been modified to facilitate Digital Displacement operation for a single piston. Prototype valves have been optimized, designed and m...

  19. Validation of lower limb segmental volumetry with hand-held, self-positioning three-dimensional laser scanner against water displacement.

    Science.gov (United States)

    Mestre, Sandrine; Veye, Florent; Perez-Martin, Antonia; Behar, Thomas; Triboulet, Jean; Berron, Nicolas; Demattei, Christophe; Quéré, Isabelle

    2014-01-01

    Measurement of limb volume is helpful for the evaluation and follow-up of edema, especially in patients with chronic venous insufficiency (CVI) or lymphedema. Water displacement (WD) is the reference method for limb volumetry but is not really suitable for clinical routine. Indirect volumetry based on circumference measurements as well as the more expansive but automatic optoelectronic techniques do not allow detailed measurement at the extremity of the limb. We used a self-positioning laser scanner with dynamic referencing for acquisition and real-time three-dimensional (3D) reconstruction of the lower limb volume in 30 patients with CVI, 30 patients with lymphedema, and 30 healthy controls. Two independent observers performed either one or two laser scans, whose results were tested for intra- and interobserver reproducibility and compared with WD volumetry by Lin's concordance correlation coefficient and Bland and Altman graphic analysis. Automatic volume calculation from 3D laser scanning data failed in one patient with major lymphedema. Lin's concordance correlation coefficient was 0.99 and 0.98, respectively, for intraobserver no. 1 and no. 2, 0.98 for interobserver reproducibility, and 0.98 and 0.96, respectively, for observer no. 1 and observer no. 2 vs WD comparison. The 3D laser scanning yielded 1.99% precision. Accuracy was 3.12% for observer no. 1 and 2.71% for observer no. 2, laser scanning values being 90 mL higher than WD, which could be attributed to the different posture during measurement. Three-dimensional laser scanning is accurate and reproducible, and appears suitable for the evaluation of limb volume in patients with CVI or lymphedema. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  20. A study of the displacement of a Wankel rotary engine

    Science.gov (United States)

    Beard, J. E.; Pennock, G. R.

    1993-03-01

    The volumetric displacement of a Wankel rotary engine is a function of the trochoid ratio and the pin size ratio, assuming the engine has a unit depth and the number of lobes is specified. The mathematical expression which defines the displacement contains a function which can be evaluated directly and a normal elliptic integral of the second type which does not have an explicit solution. This paper focuses on the contribution of the elliptic integral to the total displacement of the engine. The influence of the elliptic integral is shown to account for as much as 20 percent of the total displacement, depending on the trochoid ratio and the pin size ratio. Two numerical integration techniques are compared in the paper, namely, the trapezoidal rule and Simpson's 1/3 rule. The bounds on the error, associated with each numerical method, are analyzed. The results indicate that the numerical method has a minimal effect on the accuracy of the calculated displacement for a practical number of integration steps. The paper also evaluates the influence of manufacturing tolerances on the calculated displacement and the actual displacement. Finally. a numerical example of the common three-lobed Wankel rotary engine is included for illustrative purposes.

  1. Displacement-noise-free gravitational-wave detection

    International Nuclear Information System (INIS)

    Kawamura, Seiji; Chen Yanbei

    2004-01-01

    We present a new idea that allows us to detect gravitational waves without being disturbed by any kind of displacement noise, based on the fact that gravitational waves and test-mass motions affect the propagations of light differently. We demonstrate this idea by analyzing a simple toy model consisting of three equally-separated objects on a line. By taking a certain combination of light travel times between these objects, we construct an observable free from the displacement of each object, which has a reasonable sensitivity to gravitational waves

  2. Analysis of Statoliths Displacement in Chara Rhizoids for Validating the Microgravity-Simulation Quality of Clinorotation Modes

    Science.gov (United States)

    Krause, Lars; Braun, Markus; Hauslage, Jens; Hemmersbach, Ruth

    2018-05-01

    In single-celled rhizoids of the green algae Chara, positively gravitropic growth is governed by statoliths kept in a dynamically stable position 10-25 μ m above the cell tip by a complex interaction of gravity and actomyosin forces. Any deviation of the tube-like cells from the tip-downward orientation causes statoliths to sediment onto the gravisensitive subapical cell flank which initiates a gravitropic curvature response. Microgravity experiments have shown that abolishing the net tip-directed gravity force results in an actomyosin-mediated axial displacement of statoliths away from the cell tip. The present study was performed to critically assess the quality of microgravity simulation provided by different operational modes of a Random Positioning Machine (RPM) running with one axis (2D mode) or two axes (3D mode) and different rotational speeds (2D), speed ranges and directions (3D). The effects of 2D and 3D rotation were compared with data from experiments in real microgravity conditions (MAXUS sounding rocket missions). Rotational speeds in the range of 60-85 rpm in 2D and 3D modes resulted in a similar kinetics of statolith displacement as compared to real microgravity data, while slower clinorotation (2-11 rpm) caused a reduced axial displacement and a more dispersed arrangement of statoliths closer to the cell tip. Increasing the complexity of rotation by adding a second rotation axis in case of 3D clinorotation did not increase the quality of microgravity simulation, however, increased side effects such as the level of vibrations resulting in a more dispersed arrangement of statoliths. In conclusion, fast 2D clinorotation provides the most appropriate microgravity simulation for investigating the graviperception mechanism in Chara rhizoids, whereas slower clinorotation speeds and rotating samples around two axes do not improve the quality of microgravity simulation.

  3. Subsidence and Fault Displacement Along the Long Point Fault Derived from Continuous GPS Observations (2012-2017)

    Science.gov (United States)

    Tsibanos, V.; Wang, G.

    2017-12-01

    The Long Point Fault located in Houston Texas is a complex system of normal faults which causes significant damage to urban infrastructure on both private and public property. This case study focuses on the 20-km long fault using high accuracy continuously operating global positioning satellite (GPS) stations to delineate fault movement over five years (2012 - 2017). The Long Point Fault is the longest active fault in the greater Houston area that damages roads, buried pipes, concrete structures and buildings and creates a financial burden for the city of Houston and the residents who live in close vicinity to the fault trace. In order to monitor fault displacement along the surface 11 permanent and continuously operating GPS stations were installed 6 on the hanging wall and 5 on the footwall. This study is an overview of the GPS observations from 2013 to 2017. GPS positions were processed with both relative (double differencing) and absolute Precise Point Positioning (PPP) techniques. The PPP solutions that are referred to IGS08 reference frame were transformed to the Stable Houston Reference Frame (SHRF16). Our results show no considerable horizontal displacements across the fault, but do show uneven vertical displacement attributed to regional subsidence in the range of (5 - 10 mm/yr). This subsidence can be associated to compaction of silty clays in the Chicot and Evangeline aquifers whose water depths are approximately 50m and 80m below the land surface (bls). These levels are below the regional pre-consolidation head that is about 30 to 40m bls. Recent research indicates subsidence will continue to occur until the aquifer levels reach the pre-consolidation head. With further GPS observations both the Long Point Fault and regional land subsidence can be monitored providing important geological data to the Houston community.

  4. Displacement compressors - acceptance tests

    CERN Document Server

    International Organization for Standardization. Geneva

    1996-01-01

    ISO 1217:2009 specifies methods for acceptance tests regarding volume rate of flow and power requirements of displacement compressors. It also specifies methods for testing liquid-ring type compressors and the operating and testing conditions which apply when a full performance test is specified.

  5. Characteristics of children with hip displacement in cerebral palsy

    Directory of Open Access Journals (Sweden)

    Wagner Philippe

    2007-10-01

    Full Text Available Abstract Background Hip dislocation in children with cerebral palsy (CP is a common and severe problem. The dislocation can be avoided, by screening and preventive treatment of children with hips at risk. The aim of this study was to analyse the characteristics of children with CP who develop hip displacement, in order to optimise a hip surveillance programme. Methods In a total population of children with CP a standardised clinical and radiological follow-up of the hips was carried out as a part of a hip prevention programme. The present study is based on 212 children followed until 9–16 years of age. Results Of the 212 children, 38 (18% developed displacement with Migration Percentage (MP >40% and further 19 (9% MP between 33 and 39%. Mean age at first registration of hip displacement was 4 years, but some hips showed MP > 40% already at two years of age. The passive range of hip motion at the time of first registration of hip displacement did not differ significantly from the findings in hips without displacement. The risk of hip displacement varied according to CP-subtype, from 0% in children with pure ataxia to 79% in children with spastic tetraplegia. The risk of displacement (MP > 40% was directly related to the level of gross motor function, classified according to the gross motor function classification system, GMFCS, from 0% in children in GMFCS level I to 64% in GMFCS level V. Conclusion Hip displacement in CP often occurs already at 2–3 years of age. Range of motion is a poor indicator of hips at risk. Thus early identification and early radiographic examination of children at risk is of great importance. The risk of hip displacement varies according to both CP-subtype and GMFCS. It is sometimes not possible to determine subtype before 4 years of age, and at present several definitions and classification systems are used. GMFCS is valid and reliable from 2 years of age, and it is internationally accepted. We recommend a hip

  6. Displacing use

    DEFF Research Database (Denmark)

    Kelly, Janet; Matthews, Ben

    2014-01-01

    -centred design process. We identified alternative design-relevant relationships between people and devices that are not specifically tied to the functions/uses of the devices, e.g. relationships between the healthcare professional and the device, between doctors and patients, and between patients and their own......This paper critically discusses the concept of use in design, suggesting that relevant relationships other than use are sometimes obscured by the usercentredness of design processes. We present a design case from the medical device domain that displaced the concept of use from the centre of a human...

  7. The experimental plan of displacement- and frequency-noise free laser interferometer

    International Nuclear Information System (INIS)

    Kokeyama, K; Sato, S; Kawamura, S; Nishizawa, A; Chen, Y; Pai, A; Somiya, K; Ward, R; Sugamoto, A

    2008-01-01

    We present the partial demonstration of displacement- and laser-noise free interferometer (DFI) and the next experimental plan to examine the complete configuration. A part of the full implementation of DFI has been demonstrated to confirm the cancellation of beamsplitter displacements. The displacements were suppressed by about two orders of magnitude. The aim of the next experiment is to operate the system and to confirm the cancellation of all displacement noises, while the gravitational wave (GW) signals survive. The optical displacements will be simulated by electro-optic modulators (EOM). To simulate the GW contribution to laser lights, we will use multiple EOMs

  8. Axial linear patellar displacement: a new measurement of patellofemoral congruence.

    Science.gov (United States)

    Urch, Scott E; Tritle, Benjamin A; Shelbourne, K Donald; Gray, Tinker

    2009-05-01

    The tools for measuring the congruence angle with digital radiography software can be difficult to use; therefore, the authors sought to develop a new, easy, and reliable method for measuring patellofemoral congruence. The abstract goes here and covers two columns. The abstract goes The linear displacement measurement will correlate well with the congruence angle measurement. here and covers two columns. Cohort study (diagnosis); Level of evidence, 2. On Merchant view radiographs obtained digitally, the authors measured the congruence angle and a new linear displacement measurement on preoperative and postoperative radiographs of 31 patients who suffered unilateral patellar dislocations and 100 uninjured subjects. The linear displacement measurement was obtained by drawing a reference line across the medial and lateral trochlear facets. Perpendicular lines were drawn from the depth of the sulcus through the reference line and from the apex of the posterior tip of the patella through the reference line. The distance between the perpendicular lines was the linear displacement measurement. The measurements were obtained twice at different sittings. The observer was blinded as to the previous measurements to establish reliability. Measurements were compared to determine whether the linear displacement measurement correlated with congruence angle. Intraobserver reliability was above r(2) = .90 for all measurements. In patients with patellar dislocations, the mean congruence angle preoperatively was 33.5 degrees , compared with 12.1 mm for linear displacement (r(2) = .92). The mean congruence angle postoperatively was 11.2 degrees, compared with 4.0 mm for linear displacement (r(2) = .89). For normal subjects, the mean congruence angle was -3 degrees and the mean linear displacement was 0.2 mm. The linear displacement measurement was found to correlate with congruence angle measurements and may be an easy and useful tool for clinicians to evaluate patellofemoral

  9. Modelling the effect of electrode displacement on transcranial direct current stimulation (tDCS)

    Science.gov (United States)

    Ramaraju, Sriharsha; Roula, Mohammed A.; McCarthy, Peter W.

    2018-02-01

    Objective. Transcranial direct current stimulation (tDCS) is a neuromodulatory technique that delivers a low-intensity, direct current to cortical areas with the purpose of modulating underlying brain activity. Recent studies have reported inconsistencies in tDCS outcomes. The underlying assumption of many tDCS studies has been that replication of electrode montage equates to replicating stimulation conditions. It is possible however that anatomical difference between subjects, as well as inherent inaccuracies in montage placement, could affect current flow to targeted areas. The hypothesis that stimulation of a defined brain region will be stable under small displacements was tested. Approach. Initially, we compared the total simulated current flowing through ten specific brain areas for four commonly used tDCS montages: F3-Fp2, C3-Fp2, Fp1-F4, and P3-P4 using the software tool COMETS. The effect of a slight (~1 cm in each of four directions) anode displacement on the simulated regional current density for each of the four tDCS montages was then determined. Current flow was calculated and compared through ten segmented brain areas to determine the effect of montage type and displacement. The regional currents, as well as the localised current densities, were compared with the original electrode location, for each of these new positions. Main results. Recommendations for montages that maximise stimulation current for the ten brain regions are considered. We noted that the extent to which stimulation is affected by electrode displacement varies depending on both area and montage type. The F3-Fp2 montage was found to be the least stable with up to 38% change in average current density in the left frontal lobe while the Fp1-F4 montage was found to the most stable exhibiting only 1% change when electrodes were displaced. Significance. These results indicate that even relatively small changes in stimulation electrode placement appear to result in surprisingly large

  10. Photochemical Acceleration of DNA Strand Displacement by Using Ultrafast DNA Photo-crosslinking.

    Science.gov (United States)

    Nakamura, Shigetaka; Hashimoto, Hirokazu; Kobayashi, Satoshi; Fujimoto, Kenzo

    2017-10-18

    DNA strand displacement is an essential reaction in genetic recombination, biological processes, and DNA nanotechnology. In particular, various DNA nanodevices enable complicated calculations. However, it takes time before the output is obtained, so acceleration of DNA strand displacement is required for a rapid-response DNA nanodevice. Herein, DNA strand displacement by using DNA photo-crosslinking to accelerate this displacement is evaluated. The DNA photo-crosslinking of 3-cyanovinylcarbazole ( CNV K) was accelerated at least 20 times, showing a faster DNA strand displacement. The rate of photo-crosslinking is a key factor and the rate of DNA strand displacement is accelerated through ultrafast photo-crosslinking. The rate of DNA strand displacement was regulated by photoirradiation energy. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Improvement of the thermo-mechanical position stability of the beam position monitor in the PLS-II

    Science.gov (United States)

    Ha, Taekyun; Hong, Mansu; Kwon, Hyuckchae; Han, Hongsik; Park, Chongdo

    2016-09-01

    In the storage ring of the Pohang Light Source-II (PLS-II), we reduced the mechanical displacement of the electron-beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The BPM pickup itself must be kept stable to sub-micrometer precision in order for a stable photon beam to be provided to beamlines because the orbit feedback system is programmed to make the electron beam pass through the center of the BPM. Thermal deformation of the vacuum chambers on which the BPM pickups are mounted is inevitable when the electron beam current is changed by an unintended beam abort. We reduced this deformation by improving the vacuum chamber support and by enhancing the water cooling. We report a thermo-mechanical analysis and displacement measurements for the BPM pickups after improvements.

  12. Kicking the (barking) dog effect: the moderating role of target attributes on triggered displaced aggression.

    Science.gov (United States)

    Pedersen, William C; Bushman, Brad J; Vasquez, Eduardo A; Miller, Norman

    2008-10-01

    Sometimes aggression is displaced onto a target who is not totally innocent but emits a mildly irritating behavior called a triggering event. In three experiments, the authors examine stable personal attributes of targets that can impact such triggered displaced aggression (TDA). Lower levels of TDA were directed to targets whose attitudes were similar as compared to dissimilar to those of the actor (Experiment 1) and to targets who were ingroup as compared to out-group members (Experiment 2). Conceptually replicating the findings of Experiments 1 and 2, the manipulated valence of the target (viz., liked, neutral, and disliked) functioned in a similar manner, with positive valence serving a buffering function against a triggering action that followed an initial provocation (Experiment 3). The results from all three experiments are consistent with cognitive neoassociationist theory.

  13. Simplified Real-Time Multiplex Detection of Loop-Mediated Isothermal Amplification Using Novel Mediator Displacement Probes with Universal Reporters.

    Science.gov (United States)

    Becherer, Lisa; Bakheit, Mohammed; Frischmann, Sieghard; Stinco, Silvina; Borst, Nadine; Zengerle, Roland; von Stetten, Felix

    2018-04-03

    A variety of real-time detection techniques for loop-mediated isothermal amplification (LAMP) based on the change in fluorescence intensity during DNA amplification enable simultaneous detection of multiple targets. However, these techniques depend on fluorogenic probes containing target-specific sequences. That complicates the adaption to different targets leading to time-consuming assay optimization. Here, we present the first universal real-time detection technique for multiplex LAMP. The novel approach allows simple assay design and is easy to implement for various targets. The innovation features a mediator displacement probe and a universal reporter. During amplification of target DNA the mediator is displaced from the mediator displacement probe. Then it hybridizes to the reporter generating a fluorescence signal. The novel mediator displacement (MD) detection was validated against state-of-the-art molecular beacon (MB) detection by means of a HIV-1 RT-LAMP: MD surpassed MB detection by accelerated probe design (MD: 10 min, MB: 3-4 h), shorter times to positive (MD 4.1 ± 0.1 min shorter than MB, n = 36), improved signal-to-noise fluorescence ratio (MD: 5.9 ± 0.4, MB: 2.7 ± 0.4; n = 15), and showed equally good or better analytical performance parameters. The usability of one universal mediator-reporter set in different multiplex assays was successfully demonstrated for a biplex RT-LAMP of HIV-1 and HTLV-1 and a biplex LAMP of Haemophilus ducreyi and Treponema pallidum, both showing good correlation between target concentration and time to positive. Due to its simple implementation it is suggested to extend the use of the universal mediator-reporter sets to the detection of various other diagnostic panels.

  14. A CMOS-MEMS clamped–clamped beam displacement amplifier for resonant switch applications

    Science.gov (United States)

    Liu, Jia-Ren; Lu, Shih-Chuan; Tsai, Chun-Pu; Li, Wei-Chang

    2018-06-01

    This paper presents a micromechanical clamped–clamped beam (CC-beam) displacement amplifier based on a CMOS-MEMS fabrication process platform. In particular, a 2.0 MHz resonant displacement amplifier composed of two identical CC-beams coupled by a mechanical beam at locations where the two beams have mismatched velocities exhibits a larger displacement, up to 9.96×, on one beam than that of the other. The displacement amplification prevents unwanted input impacting—the structure switches only to the output but not the input—required by resonant switch-based mechanical circuits (Kim et al 2009 22nd IEEE Int. Conf. on Micro Electro Mechanical Systems; Lin et al 2009 15th Int. Conf. on Solid-State Sensors, Actuators, & Microsystems (TRANSDUCERS’09) Li et al 2013 17th Int. Conf. on Solid-State Sensors, Actuators, & Microsystems (TRANSDUCERS’13)). Compared to a single CC-beam displacement amplifier, theory predicts that the displacement amplifying CC-beam array yields a larger overall output displacement for displacement gain beyond 1.13 thanks to the preserved input driving force. A complete analytical model predicts the resultant stiffness and displacement gain of the coupled CC-beam displacement amplifier that match well with finite element analysis (FEA) prediction and measured results.

  15. New displacement sensor for a hybrid magnetic bearing in liquid nitrogen

    International Nuclear Information System (INIS)

    Komori, M.; Kobayashi, H.; Shiraishi, C.

    1999-01-01

    This paper describes a newly developed displacement sensor. The displacement sensor is used for a hybrid magnetic bearing in liquid nitrogen. The principle of the displacement sensor is based on a differential transformer. The sensor is found to be useful in liquid nitrogen at 77 K (-196 C). Moreover, the sensor is applied to a hybrid magnetic bearing. The displacement sensor is found to be useful and promising

  16. Serial forced displacement in American cities, 1916-2010.

    Science.gov (United States)

    Fullilove, Mindy Thompson; Wallace, Rodrick

    2011-06-01

    Serial forced displacement has been defined as the repetitive, coercive upheaval of groups. In this essay, we examine the history of serial forced displacement in American cities due to federal, state, and local government policies. We propose that serial forced displacement sets up a dynamic process that includes an increase in interpersonal and structural violence, an inability to react in a timely fashion to patterns of threat or opportunity, and a cycle of fragmentation as a result of the first two. We present the history of the policies as they affected one urban neighborhood, Pittsburgh's Hill District. We conclude by examining ways in which this problematic process might be addressed.

  17. The effect of a trunk release maneuver on Peak Pressure Index, trunk displacement and perceived discomfort in older adults seated in a High Fowler's position: a randomized controlled trial.

    Science.gov (United States)

    Best, Krista L; Desharnais, Guylaine; Boily, Jeanette; Miller, William C; Camp, Pat G

    2012-11-16

    Pressure ulcers pose significant negative individual consequences and financial burden on the healthcare system. Prolonged sitting in High Fowler's position (HF) is common clinical practice for older adults who spend extended periods of time in bed. While HF aids in digestion and respiration, being placed in a HF may increase perceived discomfort and risk of pressure ulcers due to increased pressure magnitude at the sacral and gluteal regions. It is likely that shearing forces could also contribute to risk of pressure ulcers in HF. The purpose of this study was to evaluate the effect of a low-tech and time-efficient Trunk Release Manuever (TRM) on sacral and gluteal pressure, trunk displacement and perceived discomfort in ambulatory older adults. A randomized controlled trial was used. We recruited community-living adults who were 60 years of age and older using posters, newspaper advertisements and word-of-mouth. Participants were randomly allocated to either the intervention or control group. The intervention group (n = 59) received the TRM, while the control group (n = 58) maintained the standard HF position. The TRM group had significantly lower mean (SD) PPI values post-intervention compared to the control group, 59.6 (30.7) mmHg and 79.9 (36.5) mmHg respectively (p = 0.002). There was also a significant difference in trunk displacement between the TRM and control groups, +3.2 mm and -5.8 mm respectively (p = 0.005). There were no significant differences in perceived discomfort between the groups. The TRM was effective for reducing pressure in the sacral and gluteal regions and for releasing the trunk at the point of contact between the skin and the support surface, but did not have an effect on perceived discomfort. The TRM is a simple method of repositioning which may have important clinical application for the prevention of pressure ulcers that may occur as a result of HF.

  18. Vascular Displacement in Idiopathic Macular Hole after Single-layered Inverted Internal Limiting Membrane Flap Surgery.

    Science.gov (United States)

    Lee, Jae Jung; Lee, In Ho; Park, Keun Heung; Pak, Kang Yeun; Park, Sung Who; Byon, Ik Soo; Lee, Ji Eun

    2017-08-01

    To compare vascular displacement in the macula after surgical closure of idiopathic macular hole (MH) after single-layered inverted internal limiting membrane (ILM) flap technique and conventional ILM removal. This retrospective study included patients who underwent either vitrectomy and ILM removal only or vitrectomy with single-layered inverted ILM flap for idiopathic MH larger than 400 μm from 2012 to 2015. A customized program compared the positions of the retinal vessels in the macula between preoperative and postoperative photographs. En face images of 6 × 6 mm optical coherence tomography volume scans were registered to calculate the scale. Retinal vessel displacement was measured as a vector value by comparing its location in 16 sectors of a grid partitioned into eight sectors in two rings (inner, 2 to 4 mm; outer, 4 to 6 mm). The distance and angle of displacement were calculated as an average vector and were compared between the two groups for whole sectors, inner ring, outer ring, and for each sector. Twenty patients were included in the ILM flap group and 22 in the ILM removal group. There were no statistical differences between the groups for baseline characteristics. The average displacement in the ILM flap group and the ILM removal group was 56.6 μm at -3.4° and 64.9 μm at -2.7°, respectively, for the whole sectors (p = 0.900), 76.1 μm at -1.1° and 87.3 μm at -0.9° for the inner ring (p = 0.980), and 37.4 μm at -8.2° and 42.7 μm at -6.3° for the outer ring (p = 0.314). There was no statistical difference in the displacement of each of the sectors. Postoperative topographic changes showed no significant differences between the ILM flap and the ILM removal group for idiopathic MH. The single-layered ILM flap technique did not appear to cause additional displacement of the retinal vessels in the macula. © 2017 The Korean Ophthalmological Society

  19. Disc displacement patterns in lumbar anterior spondylolisthesis: Contribution to foraminal stenosis

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Taylor, D.H.; Duke, D.; Brennan, D.D.; Eustace, S.J.

    2009-01-01

    Purpose: To describe the particular disc displacement pattern seen at MRI in patients with spondylolisthesis, and its potential contribution to foraminal stenosis. Methods: 38 patients with symptomatic lumbar anterior spondylolisthesis and 38 sex and aged matched control patients with herniated disc disease, at corresponding disc space levels, were included for study. In each case note was made of the presence, absence and direction of disc displacement and also the presence and location of neural contact with the displaced disc. Results: In 33 of 38 (86.8%) patients in the spondylolisthesis group, the vertical disc displacement was upward. In the control group only 3 patients (7.8%) had upward vertical disc displacement. 19 patients (53%) from the spondylolisthesis group had exit foraminal nerve root contact, compared to 7 patients (18.4%) from the control group. 27 control patients (71%) had contact within the lateral recess, compared to only 6 patients (17%) with spondylolisthesis. Differences for upward displacement were significant (p < 0.05). Conclusion: Disc displacement in patients with spondylolisthesis is predominately in a cephalad and lateral direction. Although this disc displacement pattern can occur in patients without spondylolisthesis, its incidence is much greater in the subset of patients with concomitant spondylolisthesis. In the setting of acquired osseous narrowing of the exit foramen, this described pattern of disc displacement superiorly and laterally in spondylolisthesis increases the susceptibility of spondylolisthesis patients to radicular symptoms and accounts for the exiting nerve root being more commonly affected than the traversing nerve root.

  20. A fiber-coupled displacement measuring interferometer for determination of the posture of a reflective surface

    International Nuclear Information System (INIS)

    Mao, Shuai; Hu, Peng-Cheng; Ding, Xue-Mei; Tan, Jiu-Bin

    2016-01-01

    A fiber-coupled displacement measuring interferometer capable of determining of the posture of a reflective surface of a measuring mirror is proposed. The newly constructed instrument combines fiber-coupled displacement and angular measurement technologies. The proposed interferometer has advantages of both the fiber-coupled and the spatially beam-separated interferometer. A portable dual-position sensitive detector (PSD)-based unit within this proposed interferometer measures the parallelism of the two source beams to guide the fiber-coupling adjustment. The portable dual PSD-based unit measures not only the pitch and yaw of the retro-reflector but also measures the posture of the reflective surface. The experimental results of displacement calibration show that the deviations between the proposed interferometer and a reference one, Agilent 5530, at two different common beam directions are both less than ±35 nm, thus verifying the effectiveness of the beam parallelism measurement. The experimental results of angular calibration show that deviations of pitch and yaw with the auto-collimator (as a reference) are less than ±2 arc sec, thus proving the proposed interferometer’s effectiveness for determination of the posture of a reflective surface.

  1. Sensitivity to feature displacement in familiar and unfamiliar faces: beyond the internal/external feature distinction.

    Science.gov (United States)

    Brooks, Kevin R; Kemp, Richard I

    2007-01-01

    Previous studies of face recognition and of face matching have shown a general improvement for the processing of internal features as a face becomes more familiar to the participant. In this study, we used a psychophysical two-alternative forced-choice paradigm to investigate thresholds for the detection of a displacement of the eyes, nose, mouth, or ears for familiar and unfamiliar faces. No clear division between internal and external features was observed. Rather, for familiar (compared to unfamiliar) faces participants were more sensitive to displacements of internal features such as the eyes or the nose; yet, for our third internal feature-the mouth no such difference was observed. Despite large displacements, many subjects were unable to perform above chance when stimuli involved shifts in the position of the ears. These results are consistent with the proposal that familiarity effects may be mediated by the construction of a robust representation of a face, although the involvement of attention in the encoding of face stimuli cannot be ruled out. Furthermore, these effects are mediated by information from a spatial configuration of features, rather than by purely feature-based information.

  2. Human response to ductless personalized ventilation coupled with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Veselý, Michal; Melikov, Arsen K.

    2012-01-01

    A human subject experiment was carried out to investigate the extent to which ductless personalized ventilation (DPV) in conjunction with displacement ventilation can improve perceived air quality (PAQ) and thermal comfort at elevated room air temperature in comparison with displacement ventilation...... alone. The experimental conditions comprised displacement ventilation alone (room air temperature of 23 °C, 26 °C, 29 °C) and DPV with displacement ventilation (26 °C, 29 °C), both operating at supply air temperatures 3, 5 or 6K lower than room air temperature, as well as mixing ventilation (23 °C, 3 K......). During one hour exposure participants answered questionnaires regarding PAQ and thermal comfort. PAQ was significantly better with DPV than without DPV at the same background conditions. Thermal comfort improved when DPV was used. Combining DPV with displacement ventilation showed the potential...

  3. The prevalence and significance of displacement for wilderness recreation management and research

    Science.gov (United States)

    Ingrid E. Schneider

    2007-01-01

    The concept of visitor displacement has important implications for wilderness management and research. Research on actual displacement of wilderness visitors is extremely limited, but this displacement likely follows patterns found for general recreationists: visitors employ a variety of coping responses and displacement is prevalent. Understanding if and when visitors...

  4. Prismatic displacement effect of progressive multifocal glasses on reaction time and accuracy in elderly people.

    Science.gov (United States)

    Ellison, Ashton C; Campbell, A John; Robertson, M Clare; Sanderson, Gordon F

    2014-01-01

    Multifocal glasses (bifocals, trifocals, and progressives) increase the risk of falling in elderly people, but how they do so is unclear. To explain why glasses with progressive addition lenses increase the risk of falls and whether this can be attributed to false projection, this study aimed to 1) map the prismatic displacement of a progressive lens, and 2) test whether this displacement impaired reaction time and accuracy. The reaction times of healthy ≥75-year-olds (31 participants) were measured when grasping for a bar and touching a black line. Participants performed each test twice, wearing their progressives and new, matched single vision (distance) glasses in random order. The line and bar targets were positioned according to the maximum and minimum prismatic displacement effect through the progressive lens, mapped using a focimeter. Progressive spectacle lenses have large areas of prismatic displacement in the central visual axis and edges. Reaction time was faster for progressives compared with single vision glasses with a centrally-placed horizontal grab bar (mean difference 101 ms, P=0.011 [repeated measures analysis]) and a horizontal black line placed 300 mm below center (mean difference 80 ms, P=0.007). There was no difference in accuracy between the two types of glasses. Older people appear to adapt to the false projection of progressives in the central visual axis. This adaptation means that swapping to new glasses or a large change in prescription may lead to a fall. Frequently updating glasses may be more beneficial.

  5. Displaced, Homeless and Abused: The Dynamics of Gender-Based ...

    African Journals Online (AJOL)

    based abuse (SPGBV) experienced by displaced Zimbabwean refugees, perpetrators of such abuses and the gender of perpetrators in South Africa. Refugee and Internally displaced persons are interchangeably used in this study. Through in-depth ...

  6. Differential Extension, Displacement Transfer, and the South to North Decrease in Displacement on the Furnace Creek - Fish Lake Valley Fault System, Western Great Basin.

    Science.gov (United States)

    Katopody, D. T.; Oldow, J. S.

    2015-12-01

    The northwest-striking Furnace Creek - Fish Lake Valley (FC-FLV) fault system stretches for >250 km from southeastern California to western Nevada, forms the eastern boundary of the northern segment of the Eastern California Shear Zone, and has contemporary displacement. The FC-FLV fault system initiated in the mid-Miocene (10-12 Ma) and shows a south to north decrease in displacement from a maximum of 75-100 km to less than 10 km. Coeval elongation by extension on north-northeast striking faults within the adjoining blocks to the FC-FLV fault both supply and remove cumulative displacement measured at the northern end of the transcurrent fault system. Elongation and displacement transfer in the eastern block, constituting the southern Walker Lane of western Nevada, exceeds that of the western block and results in the net south to north decrease in displacement on the FC-FLV fault system. Elongation in the eastern block is accommodated by late Miocene to Pliocene detachment faulting followed by extension on superposed, east-northeast striking, high-angle structures. Displacement transfer from the FC-FLV fault system to the northwest-trending faults of the central Walker Lane to the north is accomplished by motion on a series of west-northwest striking transcurrent faults, named the Oriental Wash, Sylvania Mountain, and Palmetto Mountain fault systems. The west-northwest striking transcurrent faults cross-cut earlier detachment structures and are kinematically linked to east-northeast high-angle extensional faults. The transcurrent faults are mapped along strike for 60 km to the east, where they merge with north-northwest faults forming the eastern boundary of the southern Walker Lane. The west-northwest trending transcurrent faults have 30-35 km of cumulative left-lateral displacement and are a major contributor to the decrease in right-lateral displacement on the FC-FLV fault system.

  7. 20007: Quantum particle displacement by a moving localized potential trap

    Science.gov (United States)

    Granot, E.; Marchewka, A.

    2009-04-01

    We describe the dynamics of a bound state of an attractive δ-well under displacement of the potential. Exact analytical results are presented for the suddenly moved potential. Since this is a quantum system, only a fraction of the initially confined wave function remains confined to the moving potential. However, it is shown that besides the probability to remain confined to the moving barrier and the probability to remain in the initial position, there is also a certain probability for the particle to move at double speed. A quasi-classical interpretation for this effect is suggested. The temporal and spectral dynamics of each one of the scenarios is investigated.

  8. A fast non-intercepting linac beam position and current monitor

    International Nuclear Information System (INIS)

    Hansen, J.W.; Wille, M.

    1982-01-01

    A non-intercepting beam monitor consisting of four detecting loops is used to determine the spatial postion and current of a pulsed beam from an electron linear accelerator. The monitor detects the magnetic field radiated by the substructure of the electron bunches created by the accelerating microwave. The detecting loops are interconnected two by two, by means of two coaxial hybrid junctions, the two sets positioned perpendicular to each other. By means of the two signals from the diametrically positioned detecting loops, a good spatial displacement and current monitoring sensitivity are achieved by subtracting one signal from the other and adding the two signals, respectively. For displacements below 2 mm from the center axis an average sensitivity of 0.5 mV/mm x mA is measured, whereas displacements more than 2 mm yields 1.3 mV/mm x mA. A sensitivity of 0.2 mV/mA in current monitoring is measured, and the rise time of the monitored pulse signal is better than 5 ns measured from 10 to 90% of the pulse height. Design strategy and performance of the monitor are described. (orig.)

  9. Finite element analysis of displacement actuator based on giant magnetostrictive thin film

    Directory of Open Access Journals (Sweden)

    Shaopeng Yu

    2018-05-01

    Full Text Available With the rapid development of science and technology, mechanical and electrical equipment become more and more miniature. In order to achieve precise control in less than 1cm3, the giant magnetostrictive thin film has become a research hotspot. The micro displacement actuator with planar and arc film is designed by the dynamic coupling model based on J-A model and magneto-mechanical effect method which is proposed in this paper. The different structure and thickness of films are analyzed by COMSOL Multiphysics software when the current flows through driving coil. After comparing the simulation results with the test ones, it can be seen that the coupling model is accurate and the structure is reliable. At the same time, MATLAB is used to fit the current density-displacement curve and higher order equation is obtained, and then the feasibility of design can be verified. The actuator with arc structure had advantages of small volume, fast response, high precision, easy integration, etc., which has a broad application prospect in the field of vibration control, micro positioning, robot and so on.

  10. Finite element analysis of displacement actuator based on giant magnetostrictive thin film

    Science.gov (United States)

    Yu, Shaopeng; Wang, Bowen; Zhang, Changgeng; Cui, Baozhi

    2018-05-01

    With the rapid development of science and technology, mechanical and electrical equipment become more and more miniature. In order to achieve precise control in less than 1cm3, the giant magnetostrictive thin film has become a research hotspot. The micro displacement actuator with planar and arc film is designed by the dynamic coupling model based on J-A model and magneto-mechanical effect method which is proposed in this paper. The different structure and thickness of films are analyzed by COMSOL Multiphysics software when the current flows through driving coil. After comparing the simulation results with the test ones, it can be seen that the coupling model is accurate and the structure is reliable. At the same time, MATLAB is used to fit the current density-displacement curve and higher order equation is obtained, and then the feasibility of design can be verified. The actuator with arc structure had advantages of small volume, fast response, high precision, easy integration, etc., which has a broad application prospect in the field of vibration control, micro positioning, robot and so on.

  11. Displacement in urban areas: new challenges, new partnerships.

    Science.gov (United States)

    Crisp, Jeff; Morris, Tim; Refstie, Hilde

    2012-07-01

    Rapid urbanisation is a key characteristic of the modern world, interacting with and reinforcing other global mega trends, including armed conflict, climate change, crime, environmental degradation, financial and economic instability, food shortages, underemployment, volatile commodity prices, and weak governance. Displaced people also are affected by and engaged in the process of urbanisation. Increasingly, refugees, returnees, and internally displaced persons (IDPs) are to be found not in camps or among host communities in rural areas, but in the towns and cities of developing and middle-income countries. The arrival and long-term settlement of displaced populations in urban areas needs to be better anticipated, understood, and planned for, with a particular emphasis on the establishment of new partnerships. Humanitarian actors can no longer liaise only with national governments; they must also develop urgently closer working relationships with mayors and municipal authorities, service providers, urban police forces, and, most importantly, the representatives of both displaced and resident communities. This requires linking up with those development actors that have established such partnerships already. © 2012 The Author(s). Journal compilation © Overseas Development Institute, 2012.

  12. Financing of internal displacement: excerpts from the Sri Lankan experience.

    Science.gov (United States)

    Amirthalingam, Kopalapillai; Lakshman, Rajith W D

    2010-04-01

    This paper investigates how internally displaced persons (IDPs) in Batticaloa, Sri Lanka, financed their first year of displacement. We conducted extensive fieldwork in August 2007 in numerous welfare centres in Batticaloa that have received persons displaced from the Mutur divisional secretariat (DS) in the Trincomalee district. The sample was selected from the village of Sampur in Mutur DS. The displaced from Sampur are of Tamil origin and our findings reveal certain coping strategies that may be particular to this community, including the selling or mortgaging of gold jewellery to address the effects of displacement. We found that the IDPs in this region rely heavily on jewellery and other forms of savings to ensure their survival. There is also strong evidence to support the critically important coping role played by livelihoods. These coping strategies have enabled the IDP households in the present sample to live marginally above the poverty line.

  13. Displacement length and velocity of tagged logs in the tagliamento river

    Directory of Open Access Journals (Sweden)

    Diego Ravazzolo

    2013-09-01

    Full Text Available Large wood enhance the dynamics of geomorphic processes in river systems, increases the morphological complexity of the channel bed, and provides habitats for fish and invertebrates. On the other side, if transported during high-magnitude events, large wood pieces can increase flood risks in sensitive places such as bridges and narrow cross sections prone to outbank flows. However, the dynamics and mobility of logs in rivers is poorly understood, especially in wide gravel-bed rivers. Recent studies have employed fixed video cameras to assess logs velocity, but little evidence is still available about travel length during flood events of different magnitude. This study was conducted in a valley reach of the Tagliamento river, located in the North East of Italy. The Tagliamento river is approximately 800 m wide in the study area, and is characterized by relatively high natural conditions and complex fluvial dynamics. Log mobility have been studied from June 2010 to October 2011, a period characterized by a relatively high magnitude flood in November 2010. Log mobility and displacement during floods have been measured by implanting active radio transmitters (RFID in 113 logs and GPS track devices in 42 logs. The first devices allow to recover the log after flood events by using a portable antenna, and to derive the displacement length over the monitoring period, whereas the second devices allows to calculate instantaneous (1 sec and average log velocity of moving logs. Recovery rate of logs equipped with RFID and GPS was about 50% and 60%, respectively. A preliminary analysis of the data collected indicates that there is a positive relationship between displacement length and the peak of flood events, as well as a positive relationship between log velocity and the flood magnitude. Also, a critical flow rate over which logs stranded on active bars can be transported has been identified. The ability to predict wood mobility in gravel-bed rivers could

  14. Research on Joint Parameter Inversion for an Integrated Underground Displacement 3D Measuring Sensor

    Directory of Open Access Journals (Sweden)

    Nanying Shentu

    2015-04-01

    Full Text Available Underground displacement monitoring is a key means to monitor and evaluate geological disasters and geotechnical projects. There exist few practical instruments able to monitor subsurface horizontal and vertical displacements simultaneously due to monitoring invisibility and complexity. A novel underground displacement 3D measuring sensor had been proposed in our previous studies, and great efforts have been taken in the basic theoretical research of underground displacement sensing and measuring characteristics by virtue of modeling, simulation and experiments. This paper presents an innovative underground displacement joint inversion method by mixing a specific forward modeling approach with an approximate optimization inversion procedure. It can realize a joint inversion of underground horizontal displacement and vertical displacement for the proposed 3D sensor. Comparative studies have been conducted between the measured and inversed parameters of underground horizontal and vertical displacements under a variety of experimental and inverse conditions. The results showed that when experimentally measured horizontal displacements and vertical displacements are both varied within 0 ~ 30 mm, horizontal displacement and vertical displacement inversion discrepancies are generally less than 3 mm and 1 mm, respectively, under three kinds of simulated underground displacement monitoring circumstances. This implies that our proposed underground displacement joint inversion method is robust and efficient to predict the measuring values of underground horizontal and vertical displacements for the proposed sensor.

  15. [Correlation analysis between residual displacement and hip function after reconstruction of acetabular fractures].

    Science.gov (United States)

    Ma, Kunlong; Fang, Yue; Luan, Fujun; Tu, Chongqi; Yang, Tianfu

    2012-03-01

    To investigate the relationships between residual displacement of weight-bearing and non weight-bearing zones (gap displacement and step displacement) and hip function by analyzing the CT images after reconstruction of acetabular fractures. The CT measures and clinical outcome were retrospectively analyzed from 48 patients with displaced acetabular fracture between June 2004 and June 2009. All patients were treated by open reduction and internal fixation, and were followed up 24 to 72 months (mean, 36 months); all fractures healed after operation. The residual displacement involved the weight-bearing zone in 30 cases (weight-bearing group), and involved the non weight-bearing zone in 18 cases (non weight-bearing group). The clinical outcomes were evaluated by Merle d'Aubigné-Postel criteria, and the reduction of articular surface by CT images, including the maximums of two indexes (gap displacement and step displacement). All the data were analyzed in accordance with the Spearman rank correlation coefficient analysis. There was strong negative correlation between the hip function and the residual displacement values in weight-bearing group (r(s) = -0.722, P = 0.001). But there was no correlation between the hip function and the residual displacement values in non weight-bearing group (r(s) = 0.481, P = 0.059). The results of clinical follow-up were similar to the correlation analysis results. In weight-bearing group, the hip function had strong negative correlation with step displacement (r(s) = 0.825, P = 0.002), but it had no correlation with gap displacement (r(s) = 0.577, P = 0.134). In patients with acetabular fracture, the hip function has correlation not only with the extent of the residual displacement but also with the location of the residual displacement, so the residual displacement of weight-bearing zone is a key factor to affect the hip function. In patients with residual displacement in weight-bearing zone, the bigger the step displacement is, the

  16. Displaced Electric Sail Orbits Design and Transition Trajectory Optimization

    Directory of Open Access Journals (Sweden)

    Naiming Qi

    2014-01-01

    Full Text Available Displaced orbits for spacecraft propelled by electric sails are investigated as an alternative to the use of solar sails. The orbital dynamics of electric sails based spacecraft are studied within a spherical coordinate system, which permits finding the solutions of displaced electric sail orbits and optimize transfer trajectory. Transfer trajectories from Earth's orbit to displaced orbit are also studied in an optimal framework, by using genetic algorithm and Gauss pseudospectral method. The initial guesses for the state and control histories used in the Gauss pseudospectral method are interpolated from the best solution of a genetic algorithm. Numerical simulations show that the electric sail is able to perform the transfer from Earth’s orbit to displaced orbit in acceptable time, and the hybrid optimization method has the capability to search the feasible and optimal solution without any initial value guess.

  17. Monitoring roof beam lateral displacement at the waste isolation pilot plant

    International Nuclear Information System (INIS)

    Terrill, L.J.; Lewis, R.E.

    1996-01-01

    Lateral displacement in the immediate roof beam at the Waste Isolation Pilot Plant (WIPP) is a significant factor in assessment of excavation performance for the design of ground control systems. Information on roof beam lateral displacement, expansion, fracture formation, as well as excavation convergence, is gathered using a variety of manually and remotely read instruments. Visual observations are also used when possible. This paper describes the methods used to measure lateral displacement, or offset, at the WIPP. Offset magnitudes are determined by the degree of occlusion in drillholes that intersect the offset plane. The Borehole Lateral Displacement Sensor (BLDS) was developed for installation at WIPP to monitor offset at a high degree of accuracy at a short reading frequency. Offset measurements have historically been obtained by visual estimation of borehole occlusion. Use of the BLDS will enable relationships between time dependent roof beam lateral displacement and expansion to be established in much shorter periods than is possible using visual observations. The instrument will also allow remote monitoring of roof beam displacement in areas where visual estimations are not possible. Continued monitoring of roof beam displacement, convergence, and expansion, is integral to timely and pertinent assessments of WIPP excavation performance

  18. Monitoring roof beam lateral displacement at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Terrill, L.J.; Lewis, R.E.

    1996-01-01

    Lateral displacement in the immediate roof beam at the Waste Isolation Pilot Plant (WIPP) is a significant factor in assessment of excavation performance for the design of ground control systems. Information on roof beam lateral displacement, expansion, fracture formation, as well as excavation convergence, is gathered using a variety of manually and remotely read instruments. Visual observations are also used when possible. This paper describes the methods used to measure lateral displacement, or offset, at the WIPP. Offset magnitudes are determined by the degree of occlusion in drillholes that intersect the offset plane. The Borehole Lateral Displacement Sensor (BLDS) was developed for installation at WIPP to monitor offset at a high degree of accuracy at a short reading frequency. Offset measurements have historically been obtained by visual estimation of borehole conclusion. Use of the BLDS will enable relationships between time dependent roof beam lateral displacement and expansion to be established in much shorter periods than is possible using visual observations. The instrument will also allow remote monitoring of roof beam displacement in areas where visual estimations are not possible. Continued monitoring of roof beam displacement, convergence, and expansion, is integral to timely and pertinent assessments of WIPP excavation performance

  19. Design Optimization of Moving Magnet Actuated Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Madsen, Esben Lundø; Jørgensen, Janus Martin Thastum; Nørgård, Christian

    2017-01-01

    High-efficiency hydraulic machines using digital valves are presently a topic of great focus. Digital valve performance with respect to pressure loss, closing time as well as electrical power consumption, is key to obtaining high efficiency. A recent digital seat valve design developed at Aalborg...... optimized design closes in 2.1 ms, has a pressure drop of 0.8 bar at 150 l/min and yields a digital displacement machine average chamber efficiency of 98.9%. The design is simple in construction and uses a single coil, positioned outside the pressure chamber, eliminating the need for an electrical interface...

  20. Unemployment in Iraqi Refugees: The Interaction of Pre and Post-Displacement Trauma

    Science.gov (United States)

    Wright, A. Michelle; Dhalimi, Abir; Lumley, Mark A.; Jamil, Hikmet; Pole, Nnamdi; Arnetz, Judith E.; Arnetz, Bengt B.

    2016-01-01

    Previous refugee research has been unable to link pre-displacement trauma with unemployment in the host country. The current study assessed the role of pre-displacement trauma, post-displacement trauma, and the interaction of both trauma types to prospectively examine unemployment in a random sample of newly-arrived Iraqi refugees. Participants (N=286) were interviewed three times over the first two years post-arrival. Refugees were assessed for pre-displacement trauma exposure, post-displacement trauma exposure, a history of unemployment in the country of origin and host country, and symptoms of posttraumatic stress disorder (PTSD) and depression. Analyses found that neither pre-displacement nor post-displacement trauma independently predicted unemployment 2 years post-arrival; however, the interaction of pre and post-displacement trauma predicted 2-year unemployment. Refugees with high levels of both pre and post-displacement trauma had a 91% predicted probability of unemployment, whereas those with low levels of both traumas had a 20% predicted probability. This interaction remained significant after controlling for sociodemographic variables and mental health upon arrival to the U.S. Resettlement agencies and community organizations should consider the interactive effect of encountering additional trauma after escaping the hardships of the refugee's country of origin. PMID:27535348

  1. Sensorless displacement estimation of a shape memory alloy coil spring actuator using inductance

    International Nuclear Information System (INIS)

    Kim, Hongjip; Lee, Dae-young; Cho, Kyu-Jin; Han, Yongsu; Ha, Jung-Ik

    2013-01-01

    To measure the displacement of a shape memory alloy (SMA) coil spring actuator for feedback control, displacement sensors larger than the actuator are normally required. In this study, a novel method for estimating the displacement of an SMA coil spring actuator without a sensor is proposed. Instead of a sensor, coil inductance is used for estimating the displacement. Coil inductance is estimated by measuring the voltage and the transient response of the current. It has a one-to-one relationship with the displacement of the coil and is not affected by load. Previous methods for estimating displacement using resistance measurements are heavily affected by load variations. The experimental results herein show that displacement is estimated with reasonable accuracy under varying loads using coil inductance. This sensorless method of estimating the displacement of an SMA coil spring actuator can be used to build a compact feedback controller because there is no need for a bulky displacement sensor. (paper)

  2. Small Displacement Detection of Biological Signals Using the Cyclic Frequency Method

    Directory of Open Access Journals (Sweden)

    Dan Zhang

    2015-01-01

    Full Text Available A new signal processing method called the Cyclic Frequency method is proposed for small displacement detection of vital signals such as heart rate and respiration using the CW radar method. We have presented experimental results of small displacement detection to confirm the validity of the method. The displacement amplitude 2.5 mm can be detected with a propagation frequency of 24.15 GHz. We may increase the propagation frequency for smaller displacement amplitude or target velocity.

  3. Oil/water displacement in microfluidic packed beds under weakly water-wetting conditions: competition between precursor film flow and piston-like displacement

    Science.gov (United States)

    Tanino, Yukie; Zacarias-Hernandez, Xanat; Christensen, Magali

    2018-02-01

    Optical microscopy was used to measure depth-averaged oil distribution in a quasi-monolayer of crushed marble packed in a microfluidic channel as it was displaced by water. By calibrating the transmitted light intensity to oil thickness, we account for depth variation in the fluid distribution. Experiments reveal that oil saturation at water breakthrough decreases with increasing Darcy velocity, U_{ {w}}, between capillary numbers {Ca} = μ _{ {w}} U_{ {w}}/σ = 9× 10^{-7} and 9× 10^{-6}, where μ _{ {w}} is the dynamic viscosity of water and σ is the oil/water interfacial tension, under the conditions considered presently. In contrast, end-point (long-time) remaining oil saturation depends only weakly on U_{ {w}}. This transient dependence on velocity is attributed to the competition between precursor film flow, which controls early time invasion dynamics but is inefficient at displacing oil, and piston-like displacement, which controls ultimate oil recovery. These results demonstrate that microfluidic experiments using translucent grains and fluids are a convenient tool for quantitative investigation of sub-resolution liquid/liquid displacement in porous media.

  4. Displacement and deformation measurement for large structures by camera network

    Science.gov (United States)

    Shang, Yang; Yu, Qifeng; Yang, Zhen; Xu, Zhiqiang; Zhang, Xiaohu

    2014-03-01

    A displacement and deformation measurement method for large structures by a series-parallel connection camera network is presented. By taking the dynamic monitoring of a large-scale crane in lifting operation as an example, a series-parallel connection camera network is designed, and the displacement and deformation measurement method by using this series-parallel connection camera network is studied. The movement range of the crane body is small, and that of the crane arm is large. The displacement of the crane body, the displacement of the crane arm relative to the body and the deformation of the arm are measured. Compared with a pure series or parallel connection camera network, the designed series-parallel connection camera network can be used to measure not only the movement and displacement of a large structure but also the relative movement and deformation of some interesting parts of the large structure by a relatively simple optical measurement system.

  5. Large scale intender test program to measure sub gouge displacements

    Energy Technology Data Exchange (ETDEWEB)

    Been, Ken; Lopez, Juan [Golder Associates Inc, Houston, TX (United States); Sancio, Rodolfo [MMI Engineering Inc., Houston, TX (United States)

    2011-07-01

    The production of submarine pipelines in an offshore environment covered with ice is very challenging. Several precautions must be taken such as burying the pipelines to protect them from ice movement caused by gouging. The estimation of the subgouge displacements is a key factor in pipeline design for ice gouged environments. This paper investigated a method to measure subgouge displacements. An experimental program was implemented in an open field to produce large scale idealized gouges on engineered soil beds (sand and clay). The horizontal force required to produce the gouge, the subgouge displacements in the soil and the strain imposed by these displacements were monitored on a buried model pipeline. The results showed that for a given keel, the gouge depth was inversely proportional to undrained shear strength in clay. The subgouge displacements measured did not show a relationship with the gouge depth, width or soil density in sand and clay tests.

  6. Characterization of the elastic displacement demand: Case study - Sofia city

    International Nuclear Information System (INIS)

    Paskaleva, I.; Kouteva, M.; Vaccari, F.; Panza, G.F.

    2008-02-01

    The results of the study on the seismic site response in a part of the metropolitan Sofia are discussed. The neo-deterministic seismic hazard assessment procedure has been used to compute realistic synthetic waveforms considering four earthquake scenarios, with magnitudes M = 3.7, M = 6.3 and M = 7.0. Source and site specific ground motion time histories are computed along three investigated cross sections, making use of the hybrid approach, combining the modal summation technique and the finite differences scheme. Displacement and acceleration response spectra are considered. These results are validated against the design elastic displacement response spectra and displacement demand, recommended in Eurocode 8. The elastic response design spectrum from the standard pseudo-acceleration, versus natural period, Tn, format is converted to the Sa - Sd format. The elastic displacement response spectra and displacement demand are discussed with respect to the earthquake magnitude, the seismic source-to-site distance, seismic source mechanism, and the local geological site conditions. (author)

  7. Atmospheric pressure loading effects on Global Positioning System coordinate determinations

    Science.gov (United States)

    Vandam, Tonie M.; Blewitt, Geoffrey; Heflin, Michael B.

    1994-01-01

    Earth deformation signals caused by atmospheric pressure loading are detected in vertical position estimates at Global Positioning System (GPS) stations. Surface displacements due to changes in atmospheric pressure account for up to 24% of the total variance in the GPS height estimates. The detected loading signals are larger at higher latitudes where pressure variations are greatest; the largest effect is observed at Fairbanks, Alaska (latitude 65 deg), with a signal root mean square (RMS) of 5 mm. Out of 19 continuously operating GPS sites (with a mean of 281 daily solutions per site), 18 show a positive correlation between the GPS vertical estimates and the modeled loading displacements. Accounting for loading reduces the variance of the vertical station positions on 12 of the 19 sites investigated. Removing the modeled pressure loading from GPS determinations of baseline length for baselines longer than 6000 km reduces the variance on 73 of the 117 baselines investigated. The slight increase in variance for some of the sites and baselines is consistent with expected statistical fluctuations. The results from most stations are consistent with approximately 65% of the modeled pressure load being found in the GPS vertical position measurements. Removing an annual signal from both the measured heights and the modeled load time series leaves this value unchanged. The source of the remaining discrepancy between the modeled and observed loading signal may be the result of (1) anisotropic effects in the Earth's loading response, (2) errors in GPS estimates of tropospheric delay, (3) errors in the surface pressure data, or (4) annual signals in the time series of loading and station heights. In addition, we find that using site dependent coefficients, determined by fitting local pressure to the modeled radial displacements, reduces the variance of the measured station heights as well as or better than using the global convolution sum.

  8. Distal displacement of the maxilla and the upper first molar.

    Science.gov (United States)

    Baumrind, S; Molthen, R; West, E E; Miller, D M

    1979-06-01

    Data from a sample of 198 Class II cases treated with various appliances which deliver distally directed forces to the maxilla were examined to determine the frequency of absolute distal displacement of the upper first molar and of the maxilla. Analysis revealed that such distal displacement is possible and that it is, in fact, a frequent finding following treatment. Long-range stability of distal displacement was not assessed.

  9. A retrospective review of bone tunnel enlargement after anterior cruciate ligament reconstruction with hamstring tendons fixed with a metal round cannulated interference screw in the femur.

    Science.gov (United States)

    Kobayashi, Masahiko; Nakagawa, Yasuaki; Suzuki, Takashi; Okudaira, Shuzo; Nakamura, Takashi

    2006-10-01

    To assess bone tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with the use of hamstring tendons fixed with a round cannulated interference (RCI) screw in the femur. A consecutive series of 30 ACL reconstructions performed with hamstring tendons fixed with an RCI screw in the femur and with staples via Leeds-Keio ligament in the tibia was retrospectively reviewed. The clinical outcome was evaluated through the Lysholm score. Anterior instability was tested by Telos-SE (Telos Japan, Tokyo, Japan) measurement. The location and angle of each femoral and tibial tunnel were measured with the use of plain radiographs, and bone tunnel enlargement greater than 2 mm detected any time 3, 6, 12, and 24 months postoperatively was defined as positive. Each factor (location and angle of the tunnels, sex, affected side, age, Lysholm score, and Telos-SE measurement) was compared between enlarged and nonenlarged groups. Positive enlargement of the bone tunnel (>2.0 mm) was observed in 36.7% (11 of 30) on the femoral side and 33.3% (10 of 30) on the tibial side, and in 6 knees of both sides. Half of patients (15 of 30) had an enlarged tunnel on the femoral or the tibial side until 1 year postoperatively. In most cases, enlargement reached maximum at 6 months postoperatively. Female patients tended to have an enlarged tunnel, especially on the femoral side (P < .05). Tunnel enlargement was not correlated with location and angle of the tunnels. Moreover, no difference was found in Lysholm score and Telos-SE measurement between enlarged and nonenlarged groups, although the nonenlarged group tended to exhibit higher Lysholm score and lesser instability. Bone tunnel enlargement of the femoral or tibial side was observed in half of patients (6 in both sides, 5 only in the femur, and 4 only in the tibia) after ACL reconstruction was performed with a hamstring tendon fixed with an RCI screw. Female patients had a greater chance for enlargement of the femoral tunnel

  10. The linear variable differential transformer (LVDT) position sensor for gravitational wave interferometer low-frequency controls

    Energy Technology Data Exchange (ETDEWEB)

    Tariq, Hareem E-mail: htariq@ligo.caltech.edu; Takamori, Akiteru; Vetrano, Flavio; Wang Chenyang; Bertolini, Alessandro; Calamai, Giovanni; DeSalvo, Riccardo; Gennai, Alberto; Holloway, Lee; Losurdo, Giovanni; Marka, Szabolcs; Mazzoni, Massimo; Paoletti, Federico; Passuello, Diego; Sannibale, Virginio; Stanga, Ruggero

    2002-08-21

    Low-power, ultra-high-vacuum compatible, non-contacting position sensors with nanometer resolution and centimeter dynamic range have been developed, built and tested. They have been designed at Virgo as the sensors for low-frequency modal damping of Seismic Attenuation System chains in Gravitational Wave interferometers and sub-micron absolute mirror positioning. One type of these linear variable differential transformers (LVDTs) has been designed to be also insensitive to transversal displacement thus allowing 3D movement of the sensor head while still precisely reading its position along the sensitivity axis. A second LVDT geometry has been designed to measure the displacement of the vertical seismic attenuation filters from their nominal position. Unlike the commercial LVDTs, mostly based on magnetic cores, the LVDTs described here exert no force on the measured structure.

  11. Control of DNA strand displacement kinetics using toehold exchange.

    Science.gov (United States)

    Zhang, David Yu; Winfree, Erik

    2009-12-02

    DNA is increasingly being used as the engineering material of choice for the construction of nanoscale circuits, structures, and motors. Many of these enzyme-free constructions function by DNA strand displacement reactions. The kinetics of strand displacement can be modulated by toeholds, short single-stranded segments of DNA that colocalize reactant DNA molecules. Recently, the toehold exchange process was introduced as a method for designing fast and reversible strand displacement reactions. Here, we characterize the kinetics of DNA toehold exchange and model it as a three-step process. This model is simple and quantitatively predicts the kinetics of 85 different strand displacement reactions from the DNA sequences. Furthermore, we use toehold exchange to construct a simple catalytic reaction. This work improves the understanding of the kinetics of nucleic acid reactions and will be useful in the rational design of dynamic DNA and RNA circuits and nanodevices.

  12. Searches for light sterile neutrinos with multitrack displaced vertices

    Science.gov (United States)

    Cottin, Giovanna; Helo, Juan Carlos; Hirsch, Martin

    2018-03-01

    We study discovery prospects for long-lived sterile neutrinos at the LHC with multitrack displaced vertices, with masses below the electroweak scale. We reinterpret current displaced vertex searches making use of publicly available, parametrized selection efficiencies for modeling the detector response to displaced vertices. We focus on the production of right-handed WR bosons and neutrinos N in a left-right symmetric model, and find poor sensitivity. After proposing a different trigger strategy (considering the prompt lepton accompanying the neutrino displaced vertex) and optimized cuts in the invariant mass and track multiplicity of the vertex, we find that the LHC with √{s }=13 TeV and 300 fb-1 is able to probe sterile neutrino masses between 10 GeV right-handed gauge boson mass of 2 TeV work joins other efforts in motivating dedicated experimental searches to target this low sterile neutrino mass region.

  13. The effect of a trunk release maneuver on Peak Pressure Index, trunk displacement and perceived discomfort in older adults seated in a high Fowler’s position: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Best Krista L

    2012-11-01

    Full Text Available Abstract Background Pressure ulcers pose significant negative individual consequences and financial burden on the healthcare system. Prolonged sitting in High Fowler’s position (HF is common clinical practice for older adults who spend extended periods of time in bed. While HF aids in digestion and respiration, being placed in a HF may increase perceived discomfort and risk of pressure ulcers due to increased pressure magnitude at the sacral and gluteal regions. It is likely that shearing forces could also contribute to risk of pressure ulcers in HF. The purpose of this study was to evaluate the effect of a low-tech and time-efficient Trunk Release Manuever (TRM on sacral and gluteal pressure, trunk displacement and perceived discomfort in ambulatory older adults. Method A randomized controlled trial was used. We recruited community-living adults who were 60 years of age and older using posters, newspaper advertisements and word-of-mouth. Participants were randomly allocated to either the intervention or control group. The intervention group (n = 59 received the TRM, while the control group (n = 58 maintained the standard HF position. Results The TRM group had significantly lower mean (SD PPI values post-intervention compared to the control group, 59.6 (30.7 mmHg and 79.9 (36.5 mmHg respectively (p = 0.002. There was also a significant difference in trunk displacement between the TRM and control groups, +3.2 mm and −5.8 mm respectively (p = 0.005. There were no significant differences in perceived discomfort between the groups. Conclusion The TRM was effective for reducing pressure in the sacral and gluteal regions and for releasing the trunk at the point of contact between the skin and the support surface, but did not have an effect on perceived discomfort. The TRM is a simple method of repositioning which may have important clinical application for the prevention of pressure ulcers that may occur as a result of HF.

  14. Piezoelectric displacement in ceramics

    International Nuclear Information System (INIS)

    Stewart, M.; Cain, M.; Gee, M.

    1999-01-01

    This Good Practice Guide is intended to aid a user to perform displacement measurements on piezoelectric ceramic materials such as PZT (lead zirconium titanate) in either monolithic or multilayer form. The various measurement issues that the user must consider are addressed, and good measurement practise is described for the four most suitable methods. (author)

  15. Influence of subcascade formation on displacement damage at high PKA energies

    Energy Technology Data Exchange (ETDEWEB)

    Stoller, R.E. [Oak Ridge National Lab., TN (United States); Greenwood, L.R. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-08-01

    The design of first generation fusion reactors will have to be rely on radiation effects data obtained from experiments conducted in fission reactors. Two issues must be addressed to use this data with confidence. The first is differences in the neutron energy spectrum, and the second is differences in nuclear transmutation rates. Differences in the neutron energy spectra are reflected in the energy spectra of the primary knockon atoms (PKA). The issue of PKA energy effects has been addressed through the use of displacement cascade simulations using the method of molecular dynamics (MD). Although MD simulations can provide a detailed picture of the formation and evolution of displacement cascades, they impose a substantial computational burden. However, recent advances in computing equipment permit the simulation of high energy displacement events involving more than one-million atoms; the results presented here encompass MD cascade simulation energies from near the displacement threshold to as high as 40 keV. Two parameters have been extracted from the MD simulations: the number of point defects that remain after the displacement event is completed and the fraction of the surviving interstitials that are contained in clusters. The MD values have been normalized to the number of atomic displacements calculated with the secondary displacement model by Norgett, Robinson, and Torrens (NRT).

  16. Sleep quality among internally displaced Georgian adolescents and population-based controls.

    Science.gov (United States)

    Sakhelashvili, Irine; Eliozishvili, Marine; Lortkipanidze, Nani; Oniani, Nikoloz; Cervena, Katerina; Darchia, Nato

    2016-09-01

    Sleep problems in children and adolescents are a significant public health concern and may be linked to a variety of psychoemotional difficulties. This study aimed to evaluate sleep quality and associated factors in conflict-affected Georgian adolescents after 9 months of forced displacement. Thirty-three internally displaced adolescents (mean age 11.4 years) and 33 adolescents (mean age 10.8 years) from the general population completed the Epworth Sleepiness Scale and the Children's Depression Inventory (CDI). Parents completed the Children's Sleep-Wake Scale and provided information on their socioeconomic status (SES) and the adolescents' sleep behavior, academic performance, and peer social relationships. The groups differed significantly in sleep quality, peer relationships, SES, and CDI scores. In the internally displaced group, the only significant predictor of sleep quality was SES, which increased the predictive capacity of the model (demographic and psychosocial variables) by 20% in the hierarchical analyses. The most significant predictor in the non-internally displaced group was CDI. This research indicates that displacement may affect sleep quality and psychosocial functioning. The importance of family SES as a contributing factor to displaced adolescents' poor sleep quality is highlighted. An integrated approach designed to improve the psychosocial environment of internally displaced adolescents is needed for their protection. © The Author(s) 2015.

  17. Customizing Structure-Function Displacements in the Macula for Individual Differences.

    Science.gov (United States)

    Turpin, Andrew; Chen, Siyuan; Sepulveda, Juan A; McKendrick, Allison M

    2015-09-01

    In the macula, retinal ganglion cells (RGCs) are displaced from their receptive fields. We used optical coherence tomography (OCT) to customize displacements for individual eyes by taking into account macular shape parameters, and determined the likely effect of individual anatomical differences on structure-function mapping in the central visual field. Using the population average model of Drasdo et al. as a starting point, we altered the RGC count in that model based on the ratio of an individual's RGC layer plus inner plexiform layer thickness to the population average on a pointwise basis as a function of eccentricity from the fovea. For 20 adults (age, 24-33; median age, 28) with normal vision, we computed displacements with the original model and our customized approach. We report the variance in displacements among individuals and compare the effects of such displacements on structure-function mapping of the commonly used the 10-2 visual field pattern. As expected, customizing the displacement using individual OCT data made only a small difference on average from the population-based values predicted by the Drasdo et al. model. However, the range between individuals was over 1° at many locations, and closer to 2° at some locations in the superior visual field. Individualizing macular displacement measurements based on OCT data for an individual can result in large spatial shifts in the retinal area corresponding to 10-2 locations, which may be important for clinical structure-function analysis when performed on a local, spatial scale.

  18. Contactless sub-millimeter displacement measurements

    Science.gov (United States)

    Sliepen, Guus; Jägers, Aswin P. L.; Bettonvil, Felix C. M.; Hammerschlag, Robert H.

    2008-07-01

    Weather effects on foldable domes, as used at the DOT and GREGOR, are investigated, in particular the correlation between the wind field and the stresses caused to both metal framework and tent clothing. Camera systems measure contactless the displacement of several dome points. The stresses follow from the measured deformation pattern. The cameras placed near the dome floor do not disturb telescope operations. In the set-ups of DOT and GREGOR, these cameras are up to 8 meters away from the measured points and must be able to detect displacements of less than 0.1 mm. The cameras have a FireWire (IEEE1394) interface to eliminate the need for frame grabbers. Each camera captures 15 images of 640 × 480 pixels per second. All data is processed on-site in real-time. In order to get the best estimate for the displacement within the constraints of available processing power, all image processing is done in Fourier-space, with all convolution operations being pre-computed once. A sub-pixel estimate of the peak of the correlation function is made. This enables to process the images of four cameras using only one commodity PC with a dual-core processor, and achieve an effective sensitivity of up to 0.01 mm. The deformation measurements are well correlated to the simultaneous wind measurements. The results are of high interest to upscaling the dome design (ELTs and solar telescopes).

  19. Displacive stability of a void in a void lattice

    International Nuclear Information System (INIS)

    Brailsford, A.D.

    1977-01-01

    It has recently been suggested that the stability of the void-lattice structure in irradiated metals may be attributed to the effect of the overlapping of the point-defect diffusion fields associated with each void. It is shown here, however, that the effect is much too weak. When one void is displaced from its lattice site, the displacement is shown to relax to zero as proposed, but a conservative estimate indicates that the characteristic time is equivalent to an irradiation dose of the order of 300 displacements per atom which is generally much greater than the dose necessary for void-lattice formation

  20. A displacement based FE formulation for steady state problems

    NARCIS (Netherlands)

    Yu, Y.

    2005-01-01

    In this thesis a new displacement based formulation is developed for elasto-plastic deformations in steady state problems. In this formulation the displacements are the primary variables, which is in contrast to the more common formulations in terms of the velocities as the primary variables. In a

  1. The effects of gamma irradiation on neutron displacement sensitivity of lateral PNP bipolar transistors

    International Nuclear Information System (INIS)

    Wang, Chenhui; Chen, Wei; Liu, Yan; Jin, Xiaoming; Yang, Shanchao; Qi, Chao

    2016-01-01

    The effects of gamma irradiation on neutron displacement sensitivity of four types of lateral PNP bipolar transistors (LPNPs) with different neutral base widths, emitter widths and the doping concentrations of the epitaxial base region are studied. The physical mechanisms of the effects are explored by defect analysis using deep level transient spectroscopy (DLTS) techniques and numerical simulations of recombination process in the base region of the lateral PNP bipolar transistors, and are verified by the experiments on gate-controlled lateral PNP bipolar transistors (GCLPNPs) manufactured in the identical commercial bipolar process with different gate bias voltage. The results indicate that gamma irradiation increases neutron displacement damage sensitivity of lateral PNP bipolar transistors and the mechanism of this phenomenon is that positive charge induced by gamma irradiation enhances the recombination process in the defects induced by neutrons in the base region, leading to larger recombination component of base current and greater gain degradation.

  2. The effects of gamma irradiation on neutron displacement sensitivity of lateral PNP bipolar transistors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chenhui, E-mail: wangchenhui@nint.ac.cn; Chen, Wei; Liu, Yan; Jin, Xiaoming; Yang, Shanchao; Qi, Chao

    2016-09-21

    The effects of gamma irradiation on neutron displacement sensitivity of four types of lateral PNP bipolar transistors (LPNPs) with different neutral base widths, emitter widths and the doping concentrations of the epitaxial base region are studied. The physical mechanisms of the effects are explored by defect analysis using deep level transient spectroscopy (DLTS) techniques and numerical simulations of recombination process in the base region of the lateral PNP bipolar transistors, and are verified by the experiments on gate-controlled lateral PNP bipolar transistors (GCLPNPs) manufactured in the identical commercial bipolar process with different gate bias voltage. The results indicate that gamma irradiation increases neutron displacement damage sensitivity of lateral PNP bipolar transistors and the mechanism of this phenomenon is that positive charge induced by gamma irradiation enhances the recombination process in the defects induced by neutrons in the base region, leading to larger recombination component of base current and greater gain degradation.

  3. Development of a Real-Time GPS/Seismic Displacement Meter: Seismic Component and Communications

    Science.gov (United States)

    Vernon, F.; Bock, Y.

    2002-12-01

    In two abstracts, we report on an ongoing effort to develop an Integrated Real-Time GPS/Seismic System for Orange and Western Riverside Counties, California, spanning three major strike-slip faults in southern California (San Andreas, San Jacinto, and Elsinore) and significant populations and civilian infrastructure. The system relying on existing GPS and seismic networks will collect and analyze GPS and seismic data for the purpose of estimating and disseminating real-time positions and total ground displacements (dynamic, as well as static) covering all phases of the seismic cycle, from fractions of seconds to years. Besides its intrinsic scientific use as a real-time displacement meter (transducer), the GPS/Seismic System will be a powerful tool for local and state decision makers for risk mitigation, disaster management, and structural monitoring (dams, bridges, and buildings). Furthermore, the GPS/Seismic System will become an integral part of California's spatial referencing and positioning infrastructure, which is complicated by tectonic motion, seismic displacements, and land subsidence. This development is taking place under the umbrella of the California Spatial Reference Center, in partnership with local (The Counties, Riverside County Flood and Water Conservation District, Southern California Metropolitan Water District), state (Caltrans), and Federal agencies (NGS, NASA, USGS), the geophysics community (SCEC2/SCIGN), and the private sector (RBF Consulting). The project is leveraging considerable funding, resources, and research and development from SCIGN, CSRC and two NSF-funded IT projects at UCSD and SDSU: RoadNet (Real-Time Observatories, Applications and Data Management Network) and the High Performance Wireless Research and Education Network (HPWREN). These two projects are funded to develop both the wireless networks and the integrated, seamless, and transparent information management system that will deliver seismic, geodetic, oceanographic

  4. Case report: traumatic displacement of a cochlear implant magnet.

    Science.gov (United States)

    Keereweer, Stijn; Van der Schroeff, Marc P; Pullens, Bas

    2014-04-01

    To date, over 200 000 cochlear implants (CIs) have been implanted worldwide and the incidence is still increasing. We present a case of traumatic displacement of CI magnet to raise awareness about this complication and to highlight the need for vigilance during surgery as well as for proper counseling. The clinical presentation of a 1.5-year-old boy with a traumatic displacement of a CI magnet was presented and the literature was reviewed for this rare complication. After minor head injury, the sound processor could no longer connect to the CI. X-ray imaging demonstrated displacement of the CI magnet. During revision surgery, the magnet was replaced by a new magnet in the silicon holding cap. Intraoperative impedance measurements were normal and the CI was successfully activated 4 weeks postoperatively. Clinicians and patients should be aware of the risk of displacement of the CI magnet after (minor) head injury. Young boys tend to have a higher risk for this complication.

  5. Performance of ductless personalized ventilation in conjunction with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Melikov, Arsen Krikor; Vesely, Michal

    2014-01-01

    perception of the environment. The subjects could control the position of the DPV supply diffuser and the personalized air flow (air velocity). The use of DPV improved perceived air quality and thermal comfort compared to displacement ventilation alone. At 26 °C and 29 °C the percentage dissatisfied with air......, increased eye dryness sensation was reported by 30% of subjects. The personalized air flow selected by nearly 80% of the subjects at 26 °C was between 10 and 20 l/s corresponding to the target air velocity of 1.2–1.7 m/s. At 29 °C almost 90% of subjects chose a personalized air flow between 15 and 20 l/s (1...

  6. Urban displaced youth in Kabul

    Directory of Open Access Journals (Sweden)

    Nassim Majidi

    2014-05-01

    Full Text Available Displaced young people in Kabul are waiting to see what the coming year brings for Afghanistan before making a decision as whether to move on again. This provides a window of opportunity to develop youth-sensitive programming.

  7. Temporary organ displacement coupled with image-guided, intensity-modulated radiotherapy for paraspinal tumors

    International Nuclear Information System (INIS)

    Katsoulakis, Evangelia; Thornton, Raymond H; Yamada, Yoshiya; Solomon, Stephen B; Maybody, Majid; Housman, Douglas; Niyazov, Greg; Riaz, Nadeem; Lovelock, Michael; Spratt, Daniel E; Erinjeri, Joseph P

    2013-01-01

    To investigate the feasibility and dosimetric improvements of a novel technique to temporarily displace critical structures in the pelvis and abdomen from tumor during high-dose radiotherapy. Between 2010 and 2012, 11 patients received high-dose image-guided intensity-modulated radiotherapy with temporary organ displacement (TOD) at our institution. In all cases, imaging revealed tumor abutting critical structures. An all-purpose drainage catheter was introduced between the gross tumor volume (GTV) and critical organs at risk (OAR) and infused with normal saline (NS) containing 5-10% iohexol. Radiation planning was performed with the displaced OARs and positional reproducibility was confirmed with cone-beam CT (CBCT). Patients were treated within 36 hours of catheter placement. Radiation plans were re-optimized using pre-TOD OARs to the same prescription and dosimetrically compared with post-TOD plans. A two-tailed permutation test was performed on each dosimetric measure. The bowel/rectum was displaced in six patients and kidney in four patients. One patient was excluded due to poor visualization of the OAR; thus 10 patients were analyzed. A mean of 229 ml (range, 80–1000) of NS 5-10% iohexol infusion resulted in OAR mean displacement of 17.5 mm (range, 7–32). The median dose prescribed was 2400 cGy in one fraction (range, 2100–3000 in 3 fractions). The mean GTV D min and PTV D min pre- and post-bowel TOD IG-IMRT dosimetry significantly increased from 1473 cGy to 2086 cGy (p=0.015) and 714 cGy to 1214 cGy (p=0.021), respectively. TOD increased mean PTV D95 by 27.14% of prescription (p=0.014) while the PTV D05 decreased by 9.2% (p=0.011). TOD of the bowel resulted in a 39% decrease in mean bowel D max (p=0.008) confirmed by CBCT. TOD of the kidney significantly decreased mean kidney dose and D max by 25% (0.022). TOD was well tolerated, reproducible, and facilitated dose escalation to previously radioresistant tumors abutting critical structures while

  8. All-fiber multimode interference micro-displacement sensor

    International Nuclear Information System (INIS)

    Antonio-Lopez, J E; LiKamWa, P; Sanchez-Mondragon, J J; May-Arrioja, D A

    2013-01-01

    We report an all-fiber micro-displacement sensor based on multimode interference (MMI) effects. The micro-displacement sensor consists of a segment of No-Core multimode fiber (MMF) with one end spliced to a segment of single mode fiber (SMF) which acts as the input. The other end of the MMF and another SMF are inserted into a capillary ferrule filled with index matching liquid. Since the refractive index of the liquid is higher than that of the ferrule, a liquid MMF with a diameter of 125 µm is formed between the fibers inside the ferrule. When the fibers are separated this effectively increases the length of the MMF. Since the peak wavelength response of MMI devices is very sensitive to changes in the MMF's length, this can be used to detect micro-displacements. By measuring spectral changes we have obtained a sensing range of 3 mm with a sensitivity of 25 nm mm −1 and a resolution of 20 µm. The sensor can also be used to monitor small displacements by using a single wavelength to interrogate the transmission of the MMI device close to the resonance peak. Under this latter regime we were able to obtain a sensitivity of 7000 mV mm −1 and a sensing range of 100 µm, with a resolution up to 1 µm. The simplicity and versatility of the sensor make it very suitable for many diverse applications. (paper)

  9. Point Coupled Displacement Sensor, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Real-time displacement measurement techniques are needed to acquire aerodynamic and structural system characteristics in flight. This proposal describes the...

  10. The Effect of Predicted Vehicle Displacement on Ground Crew Task Performance and Hardware Design

    Science.gov (United States)

    Atencio, Laura Ashley; Reynolds, David W.

    2011-01-01

    NASA continues to explore new launch vehicle concepts that will carry astronauts to low- Earth orbit to replace the soon-to-be retired Space Transportation System (STS) shuttle. A tall vertically stacked launch vehicle (> or =300 ft) is exposed to the natural environment while positioned on the launch pad. Varying directional winds and vortex shedding cause the vehicle to sway in an oscillating motion. Ground crews working high on the tower and inside the vehicle during launch preparations will be subjected to this motion while conducting critical closeout tasks such as mating fluid and electrical connectors and carrying heavy objects. NASA has not experienced performing these tasks in such environments since the Saturn V, which was serviced from a movable (but rigid) service structure; commercial launchers are likewise attended by a service structure that moves away from the vehicle for launch. There is concern that vehicle displacement may hinder ground crew operations, impact the ground system designs, and ultimately affect launch availability. The vehicle sway assessment objective is to replicate predicted frequencies and displacements of these tall vehicles, examine typical ground crew tasks, and provide insight into potential vehicle design considerations and ground crew performance guidelines. This paper outlines the methodology, configurations, and motion testing performed while conducting the vehicle displacement assessment that will be used as a Technical Memorandum for future vertically stacked vehicle designs.

  11. Retention of Displaced Students after Hurricanes Katrina and Rita

    Science.gov (United States)

    Coco, Joshua Christian

    2017-01-01

    The purpose of the study was to investigate the strategies that university leaders implemented to improve retention of displaced students in the aftermaths of Hurricanes Katrina and Rita. The universities that participated in this study admitted displaced students after Hurricanes Katrina and Rita. This study utilized a qualitative…

  12. load-displacement and stability characteristics of tidn-walled beams

    African Journals Online (AJOL)

    construction. Such structural ... The finite displacement formulation is used for load- displacement .... The other stress term, which is the incremental linear stress term a/ is .... formulation, only two out of the four general governing ..... 119, Paper. No. 2700 ... Deformations Spatial Buckling of Thin-Walled Beams and Frames ...

  13. 40 CFR 86.419-2006 - Engine displacement, motorcycle classes.

    Science.gov (United States)

    2010-07-01

    ... reference in § 86.1). (2) For rotary engines, displacement means the maximum volume of a combustion chamber... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Engine displacement, motorcycle... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES...

  14. A wireless laser displacement sensor node for structural health monitoring.

    Science.gov (United States)

    Park, Hyo Seon; Kim, Jong Moon; Choi, Se Woon; Kim, Yousok

    2013-09-30

    This study describes a wireless laser displacement sensor node that measures displacement as a representative damage index for structural health monitoring (SHM). The proposed measurement system consists of a laser displacement sensor (LDS) and a customized wireless sensor node. Wireless communication is enabled by a sensor node that consists of a sensor module, a code division multiple access (CDMA) communication module, a processor, and a power module. An LDS with a long measurement distance is chosen to increase field applicability. For a wireless sensor node driven by a battery, we use a power control module with a low-power processor, which facilitates switching between the sleep and active modes, thus maximizing the power consumption efficiency during non-measurement and non-transfer periods. The CDMA mode is also used to overcome the limitation of communication distance, which is a challenge for wireless sensor networks and wireless communication. To evaluate the reliability and field applicability of the proposed wireless displacement measurement system, the system is tested onsite to obtain the required vertical displacement measurements during the construction of mega-trusses and an edge truss, which are the primary structural members in a large-scale irregular building currently under construction. The measurement values confirm the validity of the proposed wireless displacement measurement system and its potential for use in safety evaluations of structural elements.

  15. A Wireless Laser Displacement Sensor Node for Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Se Woon Choi

    2013-09-01

    Full Text Available This study describes a wireless laser displacement sensor node that measures displacement as a representative damage index for structural health monitoring (SHM. The proposed measurement system consists of a laser displacement sensor (LDS and a customized wireless sensor node. Wireless communication is enabled by a sensor node that consists of a sensor module, a code division multiple access (CDMA communication module, a processor, and a power module. An LDS with a long measurement distance is chosen to increase field applicability. For a wireless sensor node driven by a battery, we use a power control module with a low-power processor, which facilitates switching between the sleep and active modes, thus maximizing the power consumption efficiency during non-measurement and non-transfer periods. The CDMA mode is also used to overcome the limitation of communication distance, which is a challenge for wireless sensor networks and wireless communication. To evaluate the reliability and field applicability of the proposed wireless displacement measurement system, the system is tested onsite to obtain the required vertical displacement measurements during the construction of mega-trusses and an edge truss, which are the primary structural members in a large-scale irregular building currently under construction. The measurement values confirm the validity of the proposed wireless displacement measurement system and its potential for use in safety evaluations of structural elements.

  16. A Combined Approach to Cartographic Displacement for Buildings Based on Skeleton and Improved Elastic Beam Algorithm

    Science.gov (United States)

    Liu, Yuangang; Guo, Qingsheng; Sun, Yageng; Ma, Xiaoya

    2014-01-01

    Scale reduction from source to target maps inevitably leads to conflicts of map symbols in cartography and geographic information systems (GIS). Displacement is one of the most important map generalization operators and it can be used to resolve the problems that arise from conflict among two or more map objects. In this paper, we propose a combined approach based on constraint Delaunay triangulation (CDT) skeleton and improved elastic beam algorithm for automated building displacement. In this approach, map data sets are first partitioned. Then the displacement operation is conducted in each partition as a cyclic and iterative process of conflict detection and resolution. In the iteration, the skeleton of the gap spaces is extracted using CDT. It then serves as an enhanced data model to detect conflicts and construct the proximity graph. Then, the proximity graph is adjusted using local grouping information. Under the action of forces derived from the detected conflicts, the proximity graph is deformed using the improved elastic beam algorithm. In this way, buildings are displaced to find an optimal compromise between related cartographic constraints. To validate this approach, two topographic map data sets (i.e., urban and suburban areas) were tested. The results were reasonable with respect to each constraint when the density of the map was not extremely high. In summary, the improvements include (1) an automated parameter-setting method for elastic beams, (2) explicit enforcement regarding the positional accuracy constraint, added by introducing drag forces, (3) preservation of local building groups through displacement over an adjusted proximity graph, and (4) an iterative strategy that is more likely to resolve the proximity conflicts than the one used in the existing elastic beam algorithm. PMID:25470727

  17. A three-frame digital image correlation (DIC) method for the measurement of small displacements and strains

    International Nuclear Information System (INIS)

    Cofaru, C; Philips, W; Van Paepegem, W

    2012-01-01

    Digital image correlation (DIC) has become a well-established approach for the calculation of full-field displacement and strains within the field of experimental mechanics. Since their introduction, DIC methods have been relying on only two images to measure the displacements and strains that materials undergo under load. It can be foreseen that the use of additional image information for the calculus of displacements and strains, although computationally more expensive, can positively impact DIC method accuracy under both ideal and challenging experimental conditions. Such accuracy improvements are especially important when measuring very small deformations, which still constitutes a great challenge: small displacements and strains translate into equally small digital image intensity changes on the material’s surface, which are affected by the digitization processes of the imaging hardware and by other image acquisition effects such as image noise. This paper proposes a new three-frame Newton–Raphson DIC method and evaluates it from the standpoints of accuracy and speed. The method models the deformations that are to be measured under the assumption that the deformation occurs at approximately the same rate between each two consecutive images in the three image sequences that are employed. The aim is to investigate how the use of image data from more than two images impacts accuracy and what is the effect on the computational speed. The proposed method is compared with the classic two-frame Newton–Raphson method in three experiments. Two experiments rely on numerically deformed images that simulate heterogeneous deformations. The third experiment uses images from a real deformation experiment. Results indicate that although it is computationally more demanding, the three-frame method significantly improves displacement and strain accuracy and is less sensitive to image noise. (paper)

  18. Lepton flavor violation with displaced vertices

    Directory of Open Access Journals (Sweden)

    Julian Heeck

    2018-01-01

    Full Text Available If light new physics with lepton-flavor-violating couplings exists, the prime discovery channel might not be ℓ→ℓ′γ but rather ℓ→ℓ′X, where the new boson X could be an axion, majoron, familon or Z′ gauge boson. The most conservative bound then comes from ℓ→ℓ′+inv, but if the on-shell X can decay back into leptons or photons, displaced-vertex searches could give much better limits. We show that only a narrow region in parameter space allows for displaced vertices in muon decays, μ→eX,X→γγ,ee, whereas tauon decays can have much more interesting signatures.

  19. Passive Smoking in a Displacement Ventilated Room

    DEFF Research Database (Denmark)

    Bjørn, Erik; Nielsen, Peter V.

    The aim of this research is to see if the displacement ventilation principle can protect a person from exposure to passive tobacco smoking. This is done by full-scale experiments with two breathing thermal manikins, smoke visualisations, and tracer gas measurements. In some situations, exhaled...... smoke will stratify in a certain height due to the vertical temperature gradient. This horizontal layer of exhaled tobacco smoke may lead to exposure. In other situations, the smoke is mixed into the upper zone, and the passive smoker is protected to some extent by the displacement principle...

  20. Simulation and experimental studies of a double-fiber angular displacement sensor

    Science.gov (United States)

    Zhu, Ruixue; Jing, Ruiping; Cheng, Yongjin

    2017-03-01

    A novel optical fiber angular displacement sensor is reported in this study. It gets the rotating angle of an object by means of the intensity modulation of a reflected light. The sensor probe, which is composed of an emitting fiber and a receiving fiber that are aligned along the vertical direction closely, is fixed directly on the rotating object. The measurements for axial displacement and angular displacement were operated separately. In particular, measurements for angular displacement were performed when the reflector is placed at different distances from the sensor probe separately. There is an excellent linearity between the angular displacement and the sensor output power. The results indicate that the larger the distance between the sensor probe and the reflector, the higher sensitivity the angular displacement sensor has. A theoretical model of the sensor is also developed and the simulate computation demonstrates that the theoretical results are in accordance with the experimental ones. The linear sensing range is ±7.2°, and the maximum sensitivity is 13.71%/deg. Furthermore, the hysteresis and the reproducibility of the measurement of the sensor are investigated. The designed sensor provides a kind of simple and effective method for measuring the angular displacement of a shaft system in practice due to its small size, light weight, good linearity and reproducibility.

  1. Assessing interventions available to internally displaced persons in Abia state, Nigeria.

    Science.gov (United States)

    Enwereji, Ee

    2009-03-01

    Internally displaced persons are faced with several problems, such as sexual violence, and deserve appropriate intervention, especially in view of the increasing prevalence of HIV/AIDS and other infections in Nigeria. This study attempts to assess interventions offered by governmental authorities and organizations to internally displaced persons and to identify gaps in services as well as to identify what needs to be strengthened. The author reviewed relevant published and unpublished documents and collected data by interviews with semi-structured questions. Twenty-five organizations and government and police departments and 55 internally displaced persons were interviewed. None of the organizations, including governmental institutions, provided social services or assistance in prevention of HIV/AIDS to internally displaced persons. The main services provided by 17 (68%) organizations to 43 (78.2%) of internally displaced persons were provision of food, clothing and money, but these were provided on an ad hoc basis. Only 3 organizations (12%) included spiritual counseling and resolution of communal conflicts in their services. The fact that most organizations, including the government, do not have services for internally displaced persons indicates lack of support for internally displaced persons. The government should be urged to include these people in most prevention services, including HIV/AIDS prevention and treatment. This should help reduce the national prevalence of HIV/AIDS.

  2. Noise cancellation properties of displacement noise free interferometer

    International Nuclear Information System (INIS)

    Sato, Shuichi; Kawamura, Seiji; Nishizawa, Atsushi; Chen Yanbei

    2010-01-01

    We have demonstrated the practical feasibility of a displacement- and frequency-noise-free laser interferometer (DFI) by partially implementing a recently proposed optical configuration using bi-directional Mach-Zehnder interferometers (MZIs). The noise cancellation efficiency was evaluated by comparing the displacement noise spectrum of the MZIs and the DFI, demonstrating up to 50 dB of noise cancellation. In addition, the possible extension of DFI as QND device is explored.

  3. Lattice Boltzmann simulation of immiscible displacement in the cavity with different channel configurations

    Science.gov (United States)

    Lou, Qin; Zang, Chenqiang; Yang, Mo; Xu, Hongtao

    In this work, the immiscible displacement in a cavity with different channel configurations is studied using an improved pseudo-potential lattice Boltzmann equation (LBE) model. This model overcomes the drawback of the dependence of the fluid properties on the grid size, which exists in the original pseudo-potential LBE model. The approach is first validated by the Laplace law. Then, it is employed to study the immiscible displacement process. The influences of different factors, such as the surface wettability, the distance between the gas cavity and liquid cavity and the surface roughness of the channel are investigated. Numerical results show that the displacement efficiency increases and the displacement time decreases with the increase of the surface contact angle. On the other hand, the displacement efficiency increases with increasing distance between the gas cavity and the liquid cavity at first and finally reaches a constant value. As for the surface roughness, two structures (a semicircular cavity and a semicircular bulge) are studied. The comprehensive results show that although the displacement processes for both the structures depend on the surface wettability, they present quite different behaviors. Specially, for the roughness structure constituted by the semicircular cavity, the displacement efficiency decreases and displacement time increases evidently with the size of the semicircular cavity for the small contact angle. The trend slows down as the increase of the contact angle. Once the contact angle exceeds a certain value, the size of the semicircular cavity almost has no influence on the displacement process. While for the roughness structure of a semicircular bulge, the displacement efficiency increases with the size of bulge first and then it decreases for the small contact angle. The displacement efficiency increases first and finally reaches a constant for the large contact angle. The results also show that the displacement time has an

  4. Association of Ipsilateral Rib Fractures With Displacement of Midshaft Clavicle Fractures.

    Science.gov (United States)

    Stahl, Daniel; Ellington, Matthew; Brennan, Kindyle; Brennan, Michael

    2017-04-01

    To determine whether the presence of ipsilateral rib fractures affects the rate of a clavicle fracture being unstable (>100% displacement). A retrospective review from 2002-2013 performed at a single level 1 trauma center evaluated 243 midshaft clavicle fractures. Single Level 1 trauma center. These fractures were subdivided into those with ipsilateral rib fractures (CIR; n = 149) and those without ipsilateral rib fractures (CnIR; n = 94). The amount of displacement was measured on the initial injury radiograph and subsequent follow-up radiographs. Fractures were classified into either 100% displacement, based on anteroposterior radiographs. Ipsilateral rib fractures were recorded based on which number rib was fractured and the total number of fractured ribs. One hundred sixteen (78%) of the CIR group and 51 (54%) of the CnIR group were found to have >100% displacement at follow-up (P = 0.0047). Seventy-two percent of the CIR group demonstrated progression from 100% displacement of the fracture compared with only 54% of the CnIR group (P fracture to >100% was 4.08 (P = 0.000194) when ribs 1-4 were fractured and not significant for rib fractures 5-8 or 9-12. The presence of concomitant ipsilateral rib fractures significantly increases the rate of midshaft clavicle fractures being >100% displaced. In addition, a fracture involving the upper one-third of the ribs significantly increases the rate of the clavicle fracture being >100% displaced on early follow-up. Clavicle fractures with associated ipsilateral rib fractures tend to demonstrate an increased amount of displacement on follow-up radiographs compared with those without ipsilateral rib fractures. Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

  5. Nonimaging speckle interferometry for high-speed nanometer-scale position detection

    NARCIS (Netherlands)

    van Putten, E.G.; Lagendijk, Aart; Mosk, Allard

    2012-01-01

    We experimentally demonstrate a nonimaging approach to displacement measurement for complex scattering materials. By spatially controlling the wavefront of the light that incidents on the material, we concentrate the scattered light in a focus on a designated position. This wavefront acts as a

  6. Optimum design of seat region in valves suitable for digital displacement machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    Digital displacement fluid power is an upcoming technology setting new standards for the achievable efficiency in variable displacement fluid power pumps and motors. In the present work, an annular seat valve suitable for use in digital displacement units is considered, and the valve geometry...

  7. Overloaded CDMA Systems with Displaced Binary Signatures

    Directory of Open Access Journals (Sweden)

    Vanhaverbeke Frederik

    2004-01-01

    Full Text Available We extend three types of overloaded CDMA systems, by displacing in time the binary signature sequences of these systems: (1 random spreading (PN, (2 multiple-OCDMA (MO, and (3 PN/OCDMA (PN/O. For each of these systems, we determine the time shifts that minimize the overall multiuser interference power. The achievable channel load with coded and uncoded data is evaluated for the conventional (without displacement and improved (with displacement systems, as well as for systems based on quasi-Welch-bound-equality (QWBE sequences, by means of several types of turbo detectors. For each system, the best performing turbo detector is selected in order to compare the performance of these systems. It is found that the improved systems substantially outperform their original counterparts. With uncoded data, (improved PN/O yields the highest acceptable channel load. For coded data, MO allows for the highest acceptable channel load over all considered systems, both for the conventional and the improved systems. In the latter case, channel loads of about 280% are achievable with a low degradation as compared to a single user system.

  8. A differential Michelson interferometer with orthogonal single frequency laser for nanometer displacement measurement

    International Nuclear Information System (INIS)

    Yan, Liping; Chen, Benyong; Wang, Bin

    2017-01-01

    A novel differential Michelson laser interferometer is proposed to eliminate the influence of environmental fluctuations for nanometer displacement measurement. This differential interferometer consists of two homodyne interferometers in which two orthogonal single frequency beams share common reference arm and partial measurement arm. By modulating the displacement of the common reference arm with a piezoelectric transducer, the common-mode displacement drift resulting from the environmental disturbances can be well suppressed and the measured displacement as differential-mode displacement signal is achieved. In addition, a phase difference compensation method is proposed for accurately determining the phase difference between interference signals by correcting the time interval according to the average speed in one cycle of interference signal. The nanometer displacement measurement experiments were performed to demonstrate the effectiveness and feasibility of the proposed interferometer and show that precision displacement measurement with standard deviation less than 1 nm has been achieved. (paper)

  9. Mechanism of vertical displacement events in JT-60U disruptive discharges

    International Nuclear Information System (INIS)

    Nakamura, Y.; Yoshino, R.; Neyatani, Y.; Tsunematsu, T.; Azumi, M.; Pomphrey, N.; Jardin, S.C.

    1996-01-01

    Enhanced vertical displacement events (VDEs), which are frequently observed in JT-60U disruptive discharges, are investigated using the Tokamak Simulation Code (TSC). The rapid plasma current quench can accelerate the vertical displacement, owing to both the up/down asymmetry of the eddy current distribution arising from the asymmetric geometry of the JT-60U vacuum vessel and the degradation of magnetic field decay index n, leading to high growth rates of positional instability. For a slightly elongated configuration (n = -0.9), the asymmetry of attractive forces on the toroidal plasma plays a dominant role in the VDE mechanism. For a more elongated configuration (n = -1.7), the degradation of field decay index n plays an important role on VDEs, in addition to the effect of asymmetric attractive forces. It is shown that the VDE characteristics of a highly elongated configuration with a rapid plasma current quench can be dominated by the field decay index degradation. It is also pointed out that both the softening of current quenches as was experimentally developed in the JT-60U tokamak, and the optimization of the allowable elongation of the plasma cross-section are critical issues in the development of a general control strategy of discharge termination. (author). 21 refs, 10 figs

  10. A Novel Computational Method to Reduce Leaky Reaction in DNA Strand Displacement

    Directory of Open Access Journals (Sweden)

    Xin Li

    2015-01-01

    Full Text Available DNA strand displacement technique is widely used in DNA programming, DNA biosensors, and gene analysis. In DNA strand displacement, leaky reactions can cause DNA signals decay and detecting DNA signals fails. The mostly used method to avoid leakage is cleaning up after upstream leaky reactions, and it remains a challenge to develop reliable DNA strand displacement technique with low leakage. In this work, we address the challenge by experimentally evaluating the basic factors, including reaction time, ratio of reactants, and ion concentration to the leakage in DNA strand displacement. Specifically, fluorescent probes and a hairpin structure reporting DNA strand are designed to detect the output of DNA strand displacement, and thus can evaluate the leakage of DNA strand displacement reactions with different reaction time, ratios of reactants, and ion concentrations. From the obtained data, mathematical models for evaluating leakage are achieved by curve derivation. As a result, it is obtained that long time incubation, high concentration of fuel strand, and inappropriate amount of ion concentration can weaken leaky reactions. This contributes to a method to set proper reaction conditions to reduce leakage in DNA strand displacement.

  11. Position control of ECRH launcher mirrors by laser speckle sensor

    International Nuclear Information System (INIS)

    Michelsen, Poul K.; Bindslev, Henrik; Hansen, Rene Skov; Hanson, Steen G.

    2003-01-01

    The planned ECRH system for JET included several fixed and steerable mirrors some of which should have been fixed to the building structure and some to the JET vessel structure. A similar system may be anticipated for ITER and for other fusion devices in the future. In order to have high reproducibility of the ECRH beam direction, it is necessary to know the exact positions of the mirrors. This is not a trivial problem because of thermal expansion of the vessel structures and of the launcher itself and of its support structure, the mechanical load on mirrors and support structures, and the accessibility to the various mirrors. We suggest to use a combination of infrared diagnostic of beam spot positions and a new technique published recently, which is based on a non-contact laser speckle sensor for measuring one- and two-dimensional angular displacement. The method is based on Fourier transforming the scattered field from a single laser beam that illuminates the target. The angular distribution of the light field at the target is linearly mapped onto an array image sensor placed in the Fourier plane. Measuring the displacement of this so-called speckle pattern facilitates the determination of the mirror orientation. Transverse target movement can be measured by observing the speckle movement in the image plane of the object. No special surface treatment is required for surfaces having irregularities of the order of or larger than the wavelength of the incident light. For the JET ECRH launcher it is mainly for the last mirror pointing towards the plasma where the technique may be useful. This mirror has to be steerable in order to reflect the microwave beam in the correct direction towards the plasma. Maximum performance of the microwave heating requires that the beam hits this mirror at its centre and that the mirror is turned in the correct angle. Inaccuracies in the positioning of the pull rods for controlling the mirror turning and thermal effects makes it

  12. Development of a High Precision Displacement Measurement System by Fusing a Low Cost RTK-GPS Sensor and a Force Feedback Accelerometer for Infrastructure Monitoring.

    Science.gov (United States)

    Koo, Gunhee; Kim, Kiyoung; Chung, Jun Yeon; Choi, Jaemook; Kwon, Nam-Yeol; Kang, Doo-Young; Sohn, Hoon

    2017-11-28

    A displacement measurement system fusing a low cost real-time kinematic global positioning system (RTK-GPS) receiver and a force feedback accelerometer is proposed for infrastructure monitoring. The proposed system is composed of a sensor module, a base module and a computation module. The sensor module consists of a RTK-GPS rover and a force feedback accelerometer, and is installed on a target structure like conventional RTK-GPS sensors. The base module is placed on a rigid ground away from the target structure similar to conventional RTK-GPS bases, and transmits observation messages to the sensor module. Then, the initial acceleration, velocity and displacement responses measured by the sensor module are transmitted to the computation module located at a central monitoring facility. Finally, high precision and high sampling rate displacement, velocity, and acceleration are estimated by fusing the acceleration from the accelerometer, the velocity from the GPS rover, and the displacement from RTK-GPS. Note that the proposed displacement measurement system can measure 3-axis acceleration, velocity as well as displacement in real time. In terms of displacement, the proposed measurement system can estimate dynamic and pseudo-static displacement with a root-mean-square error of 2 mm and a sampling rate of up to 100 Hz. The performance of the proposed system is validated under sinusoidal, random and steady-state vibrations. Field tests were performed on the Yeongjong Grand Bridge and Yi Sun-sin Bridge in Korea, and the Xihoumen Bridge in China to compare the performance of the proposed system with a commercial RTK-GPS sensor and other data fusion techniques.

  13. Directional dependence of the threshold displacement energies in metal oxides

    Science.gov (United States)

    Cowen, Benjamin J.; El-Genk, Mohamed S.

    2017-12-01

    Molecular dynamics (MD) simulations are performed to investigate the directional dependence and the values of the threshold energies (TDEs) for the displacements of the oxygen and metal atoms and for producing stable Frenkel pairs in five metal oxides of Cr2O3, Al2O3, TiO2, SiO2, and MgO. The TDEs for the Frenkel pairs and atoms displacement are calculated in 66 crystallographic directions, on both the anion and cation sublattices. The performed simulations are for metal and oxygen PKA energies up to 350 and 400 eV, respectively. The calculated probability distributions for the atoms displacement and average number of Frenkel pairs produced in the different oxides are compared. The results revealed unique symmetrical patterns of the TDEs for the displacement of the atoms and the formation of stable Frenkel pairs, confirming the strong dependence on the direction and the crystalline structure of the oxides. Results also showed that the formation of stable Frenkel pairs is associated with the displacements of the PKAs and/or of the SKAs. The probabilities of the TDEs for the displacement of the oxygen and metal PKAs are consistently lower than those of the atoms in the crystal. In SiO2, TDEs for the displacement of oxygen and metal atoms and those for the formation of stable Frenkel pairs are the lowest, while those in TiO2 are among the highest. The results for Cr2O3 and Al2O3, which have the same crystal structure, are similar. The calculated TDEs for MgO, Al2O3 and TiO2 are generally in good agreement with the experimental values and the probability distributions of the TDEs for the PKAs in TiO2 are in good agreement with reported MD simulation results.

  14. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK).

    Science.gov (United States)

    Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen

    2017-01-01

    Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of -0.75 D to 1.0 D ×175° in her right eye 1 month later. We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management.

  15. Mental health problems among internally displaced persons in Darfur.

    Science.gov (United States)

    Hamid, Abdalla A R M; Musa, Saif A

    2010-08-01

    War victims are regarded as one of the highest risk groups for mental disturbances. This study investigated the effects of the Darfur conflict on mental health of 430 internally displaced persons (IDPs) from three camps located around Fasher and Nyala towns. A stratified random sampling technique was used to select participants. Male participants represented 50.6% of the sample while female participants represented 49.4%. The Posttraumatic Stress Disorder Checklist and the General Health Questionnaire (GHQ-28) were used in addition to a questionnaire measuring demographic variables and living conditions. It was hypothesized that high prevalence of posttraumatic stress disorder (PTSD) symptoms and of nonpsychotic psychiatric symptoms will be evident. Results showed a high dissatisfaction rate (72%) with living conditions among IDPs. There was also high prevalence of PTSD (54%) and general distress (70%) among IDPs. Female participants showed more somatic symptoms than their male counterparts. Married participants were more distressed, anxious, and showed more social dysfunction, while single ones reported more avoidance symptoms. Significant differences related to date of displacement were found in PTSD and hyperarousal. The group of IDPs displaced in 2003 scored higher on these scales than those displaced in 2004 and 2005. There was also significant difference related to date of displacement in distress, somatic symptoms, depression, anxiety, and social dysfunction. IDPs displaced in 2003 scored higher on these scales. Results are discussed in light of the study hypotheses and previous findings. It is concluded that three factors might affect the dissatisfaction of IDPs with living conditions inside camps. These are: lack of employment, unsuitability of food items, and lack of security around camps. It was recommended that psychological support services should be among the prime relief services provided by aid agencies.

  16. Patient positioning in radiotherapy based on surface imaging using time of flight cameras

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, M., E-mail: marlene.gilles@univ-brest.fr; Fayad, H.; Clement, J. F.; Bert, J.; Visvikis, D. [INSERM, UMR 1101, LaTIM, Brest 29609 (France); Miglierini, P. [Academic Radiotherapy Department, CHRU Morvan, Brest 29200 (France); Scheib, S. [Varian Medical Systems Imaging Laboratory GmbH, Baden-Daettwil 5405 (Switzerland); Cozzi, L. [Radiotherapy and Radiosurgery Department, Instituto Clinico Humanitas, Rozzano 20089 (Italy); Boussion, N.; Schick, U.; Pradier, O. [INSERM, UMR 1101, LaTIM, Brest 29609, France and Academic Radiotherapy Department, CHRU Morvan, Brest 29200 (France)

    2016-08-15

    Purpose: To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. Methods: A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, and head and neck cancer patients. Results: The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. Conclusions: The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).

  17. On the atomic displacement fields of small interstitial dislocation loops

    International Nuclear Information System (INIS)

    Zhou, Z.; Dudarev, S.L.; Jenkins, M.L.; Sutton, A.P.; Kirk, M.A.

    2005-01-01

    The atomic displacement fields of dislocation loops of size 1-5 nm formed by self-interstitial atoms in α-Fe have been calculated using isotropic elasticity theory and anisotropic elasticity theory, and compared with atomic simulations for loops formed by 43-275 self-interstitial atoms. The atomic displacements predicted by anisotropic elasticity theory were in good agreement with those given by the atomistic simulations at distances greater than 3 nm from the loop plane, but the displacements predicted by isotropic elasticity theory showed significant discrepancies at distances up to 15 nm

  18. Change in coastal sedimentation conditions due to positive shore displacement in Oeregrundsgrepen

    International Nuclear Information System (INIS)

    Brydsten, Lars

    1999-12-01

    This report is a part the SKB project 'SAFE' (Safety Assessment of the Final Repository of Radioactive Operational Waste). The aim of project SAFE is to update the previous safety analysis of SFR-1. SFR-1 is a low and intermediate level radioactive waste disposal facility, which is situated in bedrock beneath the Baltic Sea, 1 km off the coast near the Forsmark Nuclear Power Plant. At a possible discharge of radionuclides from SFR-1 today, ground water currents will presumably transport the radionuclides to the sea bottom. Many radionuclides are able to absorb on to fine particles, and it is likely that the radionuclides would adsorb on to particles in the sediment or particles suspended in the seawater. The adsorption is strong, and therefore the dynamics of the radionuclides are governed by the dynamics of the fine particles. A mathematical model has been developed to simulate the resuspension of fine particles caused by wave movement. The model simulates the wave-induced near bottom water dynamics based on meteorological data. First, the wave's characteristics in deep water are calculated. Then the gradual change of the wave's characteristics is calculated as it reaches shallower water. The maximum near-bottom orbital velocity is calculated for the entire fetch distance, and the wave's ability to resuspend fine-grained particles is determined using well-known semiempirical methods. A large variety of weather conditions are simulated and the results are shown as a map for two different bottom types: accumulated bottoms (continual accumulation of fine grained particles and any radionuclides present) and erosional/accumulation bottoms (periods with accumulation alternating with periods with erosion). The model has been calibrated for four areas close to SFR-1, which provides a range of different sedimentation conditions. Since shore displacement is positive, currently approximately 60 cm per century, sedimentation conditions have fluctuated and will continue to

  19. Vertical displacement of the brain and the target area during open stereotaxic neurosurgery

    International Nuclear Information System (INIS)

    Wester, K.; Kraekenes, J.

    2001-01-01

    During stereotaxic thalamotomies, we observed that the brain surface was sinking. The study was carried out to investigate to what extent the target area also was displaced and how this would affect the accuracy of the stereotaxic procedure. In 12 thalamotomies, with the patients operated on in the sitting position, we found that the cortical surface sank 0-9 (mean 5) mm during the operation. The vertical co-ordinate of the thalamic target was consequently adjusted per-operatively, and the electrodes were advanced on additional distance of 1-5.5 (mean 3.5) mm in an attempt to compensate for the assumed sinking of the target. This per-operative adjustment was based on the surgeon's experience and the results of macro-stimulation studies. The exact location of the thalamotomy lesion, and thereby the accuracy of the adjustment, was evaluated on 3 months postoperative CT scans. These showed that the intended target was hit with a sufficient degree of accuracy in all the patients, although the vertical co-ordinate had been slightly over-adjusted, as the center of the lesion on the average was located 1 mm below the intended location. Thus, if the vertical position had not been adjusted, the lesion would on the average have been located 2.5 mm too high compared with the intended target. Patients undergoing thalamotomy and other stereotaxic procedures, where a high degree of accuracy is needed, should be operated on in the sitting position. At the thalamic level, the vertical displacement of the target should be adjusted for by additional advancement of the stereotaxic probe. On average, this compensatory adjustment should be about half the per-operative sinking of the cortical surface. (author)

  20. DNA fork displacement rates in human cells

    International Nuclear Information System (INIS)

    Kapp, L.N.; Painter, R.B.

    1981-01-01

    DNA fork displacement rates were measured in 20 human cell lines by a bromodeoxyuridine-313 nm photolysis technique. Cell lines included representatives of normal diploid, Fanconi's anemia, ataxia telangiectasia, xeroderma pigmentosum, trisomy-21 and several transformed lines. The average value for all the cell lines was 0.53 +- 0.08 μm/min. The average value for individual cell lines, however, displayed a 30% variation. Less than 10% of variation in the fork displacement rate appears to be due to the experimental technique; the remainder is probably due to true variation among the cell types and to culture conditions. (Auth.)

  1. DNA fork displacement rates in human cells

    Energy Technology Data Exchange (ETDEWEB)

    Kapp, L.N.; Painter, R.B. (California Univ., San Francisco (USA). Lab. of Radiobiology)

    1981-11-27

    DNA fork displacement rates were measured in 20 human cell lines by a bromodeoxyuridine-313 nm photolysis technique. Cell lines included representatives of normal diploid, Fanconi's anemia, ataxia telangiectasia, xeroderma pigmentosum, trisomy-21 and several transformed lines. The average value for all the cell lines was 0.53 +- 0.08 ..mu..m/min. The average value for individual cell lines, however, displayed a 30% variation. Less than 10% of variation in the fork displacement rate appears to be due to the experimental technique; the remainder is probably due to true variation among the cell types and to culture conditions.

  2. Bucket Foundation Response Under Various Displacement Rates

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2016-01-01

    in a multi-bucket foundation system. The foundation model is at a scale of approximately 1:20 prototype foundation size. The tests are performed in a pressure tank with the foundation model installed in dense sand. Based on the data, the conclusion is that the bucket foundation design in a storm case should......The present testing program aims at showing the pore pressure response around a bucket foundation skirt as well as the load and displacement change due to ten different displacement rates. Research findings are useful for a numerical model calibration focusing on the design of the upwind foundation...

  3. 187 DISPLACEMENT AND ENVIRONMENTAL PROTECTION

    African Journals Online (AJOL)

    Fr. Ikenga

    The national and international communities are confronted with the monumental task of ... displacement and environmental protection present a vicious cycle which today has ... Thus, issues of environmental protection viz-a-viz investment and .... out the conditions for product or process standards, the use of best available ...

  4. Hyoid Displacement in Post-Treatment Cancer Patients: Preliminary Findings

    Science.gov (United States)

    Zu, Yihe; Yang, Zhenyu; Perlman, Adrienne L.

    2011-01-01

    Purpose: Dysphagia after head and neck cancer treatment is a health care issue; in some cases, the cause of death is not cancer but, rather, the passage of food or liquid into the lungs. Hyoid displacement is known to be important to safe swallowing function. The purpose of this study was to evaluate hyoid displacement after cancer treatment.…

  5. Retrospective evaluation of positional movements of patients with prostate cancer submitted to IGRT (radiotherapy guided by image)

    International Nuclear Information System (INIS)

    Rocha, N.K.S.; Filipov, D.; Soboll, D.S.

    2017-01-01

    It is a retrospective study that analyzed positional fluctuations of 29 patients submitted to prostate radiotherapy, using IGRT. The minimum and maximum averages of the lateral, longitudinal and vertical displacements were calculated, obtaining a general average of the displacements that remained close to zero and one the most evident variation between the lateral and vertical axes

  6. Measurements of plasma position in TJ-I Tokamak

    International Nuclear Information System (INIS)

    Qin, J.; Ascasibar, E.; Navarro, A.P.; Ochando, M.A.; Pastor, I.; Pedrosa, M.A.; Rodriguez, L.; Sanchez, J.; Team, TJ-I.

    1994-01-01

    This report presents the experimental measurements of plasma position in TJ-I tokamak by using small magnetic probes. The basis of method has been described in our previous work (1) in which the plasma current is considered as a filament current. The observed relations between the disruptive instabilities and plasma displacements are also show here. (Author) 7 refs

  7. Seismic characteristics and identification of negative flower structures, positive flower structures, and positive structural inversion

    Energy Technology Data Exchange (ETDEWEB)

    Harding, T.P.

    1985-04-01

    Negative and positive flower structures and positive inverted structures imply specific modes of formation, and their distinctive characteristics make them important criteria for the identification of certain structural styles. A negative flower structure from the Andaman Sea consists of a shallow synform bounded by upward-spreading strands of a wrench fault that have mostly normal separations. Paralleling monoclines and oblique, en echelon normal faults flank the divergent wrench fault. A positive flower structure from the Ardmore basin, Oklahoma, consists of a shallow antiform displaced by the upward diverging strands of a wrench fault that have mostly reverse separations. En echelon folds are present on either side of this convergent wrench fault. Positive structural inversion at the Rambutan oil field, South Sumatra basin, has formed a shallow anticlinorium and has partly uplifted the underlying graben. Deeper fault segments bounding the graben have retained their normal fault profiles, but at shallow levels some of these faults have reverse separations.

  8. 5 CFR 330.607 - Notification of surplus and displaced employees.

    Science.gov (United States)

    2010-01-01

    ... employees. 330.607 Section 330.607 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS RECRUITMENT, SELECTION, AND PLACEMENT (GENERAL) Agency Career Transition Assistance Plans (CTAP) for Local Surplus and Displaced Employees § 330.607 Notification of surplus and displaced employees...

  9. Viscous Flow with Large Fluid-Fluid Interface Displacement

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Koblitz; Hassager, Ole; Saasen, Arild

    1998-01-01

    The arbitrary Lagrange-Euler (ALE) kinematic description has been implemented in a 3D transient finite element program to simulate multiple fluid flows with fluid-fluid interface or surface displacements. The description of fluid interfaces includes variable interfacial tension, and the formulation...... is useful in the simulation of low and intermediate Reynolds number viscous flow. The displacement of two immiscible Newtonian fluids in a vertical (concentric and eccentric) annulus and a (vertical and inclined)tube is simulated....

  10. Origins of displacements caused by underground nuclear explosions

    International Nuclear Information System (INIS)

    Rinehart, John S.

    1970-01-01

    Elastic theory has been used to calculate the relative displacement that will occur between the two sides of a loose boundary when a plane wave strikes the boundary obliquely. The calculations suggest that the displacements produced along loose fractures and faults close in to the underground nuclear explosions are a direct consequence of reflection of the transient stress wave at this loose boundary. Quantitatively the results agree fairly well with the limited data that are available. (author)

  11. Origins of displacements caused by underground nuclear explosions

    Energy Technology Data Exchange (ETDEWEB)

    Rinehart, John S [ESSA Research Laboratories, and Department of Mechanical Engineering, University of Colorado, Boulder, CO (United States)

    1970-05-15

    Elastic theory has been used to calculate the relative displacement that will occur between the two sides of a loose boundary when a plane wave strikes the boundary obliquely. The calculations suggest that the displacements produced along loose fractures and faults close in to the underground nuclear explosions are a direct consequence of reflection of the transient stress wave at this loose boundary. Quantitatively the results agree fairly well with the limited data that are available. (author)

  12. The Displaced Female Voice: Poetry of Natalya Gorbanevskaya

    Directory of Open Access Journals (Sweden)

    Muneerah Badr Almahasheer

    2017-05-01

    Full Text Available Natalya Gorbanevskaya’s poetry uses unanchored imagery, direct address, and other specific means of creating a mood of rootlessness that is ambiguous and echoes her own experience as a Russian exile. Her work focuses on themes of displacement and trauma that are common to those who are forcibly made to leave their homes. This article is one of the first close readings of selected poems by Gorbanevskaya that is to merit attention to her displacement, marginalized feminine identity and resistance to the hegemony of political repression. The loss of her home in a literal and a geographical sense, and her status as an expatriate in Paris, can be understood as a complete displacement for Gorbanevskaya, forging her identity as a political refugee poet. Her work further reveals the power of poetry in reclaiming identity, asserting memory, and resisting the patriarchal system.

  13. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK

    Directory of Open Access Journals (Sweden)

    Tsai TH

    2017-04-01

    Full Text Available Tsung-Han Tsai,1 Kai-Ling Peng,1 Chien-Jen Lin2 1Department of Ophthalmology, 2Department of Radiology, Chi Mei Medical Center, Tainan, Taiwan Background: Laser in situ keratomileusis (LASIK is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK.Case presentation: A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of −0.75 D to 1.0 D ×175° in her right eye 1 month later.Literature review: We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014.Conclusion: Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could

  14. On the biophysics and kinetics of toehold-mediated DNA strand displacement.

    Science.gov (United States)

    Srinivas, Niranjan; Ouldridge, Thomas E; Sulc, Petr; Schaeffer, Joseph M; Yurke, Bernard; Louis, Ard A; Doye, Jonathan P K; Winfree, Erik

    2013-12-01

    Dynamic DNA nanotechnology often uses toehold-mediated strand displacement for controlling reaction kinetics. Although the dependence of strand displacement kinetics on toehold length has been experimentally characterized and phenomenologically modeled, detailed biophysical understanding has remained elusive. Here, we study strand displacement at multiple levels of detail, using an intuitive model of a random walk on a 1D energy landscape, a secondary structure kinetics model with single base-pair steps and a coarse-grained molecular model that incorporates 3D geometric and steric effects. Further, we experimentally investigate the thermodynamics of three-way branch migration. Two factors explain the dependence of strand displacement kinetics on toehold length: (i) the physical process by which a single step of branch migration occurs is significantly slower than the fraying of a single base pair and (ii) initiating branch migration incurs a thermodynamic penalty, not captured by state-of-the-art nearest neighbor models of DNA, due to the additional overhang it engenders at the junction. Our findings are consistent with previously measured or inferred rates for hybridization, fraying and branch migration, and they provide a biophysical explanation of strand displacement kinetics. Our work paves the way for accurate modeling of strand displacement cascades, which would facilitate the simulation and construction of more complex molecular systems.

  15. General Series Solutions for Stresses and Displacements in an Inner-fixed Ring

    Science.gov (United States)

    Jiao, Yongshu; Liu, Shuo; Qi, Dexuan

    2018-03-01

    The general series solution approach is provided to get the stress and displacement fields in the inner-fixed ring. After choosing an Airy stress function in series form, stresses are expressed by infinite coefficients. Displacements are obtained by integrating the geometric equations. For an inner-fixed ring, the arbitrary loads acting on outer edge are extended into two sets of Fourier series. The zero displacement boundary conditions on inner surface are utilized. Then the stress (and displacement) coefficients are expressed by loading coefficients. A numerical example shows the validity of this approach.

  16. ANALYTICAL MODEL FOR LATHE TOOL DISPLACEMENTS CALCULUS IN THE MANUFACTURING P ROCESS

    Directory of Open Access Journals (Sweden)

    Catălin ROŞU

    2014-01-01

    Full Text Available In this paper, we present an analytical model for lathe tools displacements calculus in the manufacturing process. We will present step by step the methodology for the displacements calculus and in the end we will insert these relations in a program for automatic calculus and we extract the conclusions. There is taken into account only the effects of the bending moments (because these insert the highest displacements. The simplifying assumptions and the calculus relations for the displacements (linea r and angular ones are presented in an original way.

  17. Study on the applicability of the desk displacement ventilation concept

    NARCIS (Netherlands)

    Loomans, Marcel G.L.C.

    1999-01-01

    This paper summarizes an experimental and numerical study into a ventilation concept that combines displacement ventilation with task conditioning, the so-called desk displacement ventilation (DDV) concept. The study uses steady-state and transient results to discuss the applicability of the DDV

  18. Iraqi Refugees and Internally Displaced Persons: A Deepening Humanitarian Crisis

    National Research Council Canada - National Science Library

    Margesson, Rhoda; Sharp, Jeremy M; Bruno, Andorra

    2007-01-01

    .... It is estimated that in total (including those displaced prior to the war) there may be 2 million Iraqi refugees who have fled to Jordan, Syria, and other neighboring states, and approximately 2 million Iraqis who have been displaced within Iraq itself...

  19. Atomic displacements in dilute alloys of Cr, Nb and Mo

    Indian Academy of Sciences (India)

    physics pp. 497–514. Atomic displacements in dilute alloys of Cr, Nb and Mo ... used to calculate dynamical matrix and the impurity-induced forces up to second nearest ... origin, the lattice is strained, and the host atoms get displaced to new ...

  20. Does Donor Age of Nonirradiated Achilles Tendon Allograft Influence Mid-Term Results of Revision ACL Reconstruction?

    Science.gov (United States)

    Zaffagnini, Stefano; Roberti di Sarsina, Tommaso; Bonanzinga, Tommaso; Nitri, Marco; Macchiarola, Luca; Stefanelli, Federico; Lucidi, Gianandrea; Grassi, Alberto

    2018-01-01

    Purpose  The purpose of the present study was to investigate if the donor age of nonirradiated Achilles tendon allograft could influence the clinical results of revision anterior cruciate ligament (ACL) reconstruction. Methods  All patients that underwent ACL revision between 2004 and 2008 with at least 4 years of follow-up were included. For all the patients that met the inclusion criteria, the age of the graft donor was obtained from the tissue bank. Lysholm score was administered to patients that met inclusion criteria. In addition, patients were divided in two groups based on the donor age (<45 years vs. ≥45 years), and the baseline characteristics and outcomes were compared. Results  Fifty-two patients were evaluated at a mean 4.8 ± 0.8 years follow-up with Lysholm score. The Lysholm significantly improved from 62.3 ± 6.6 at preoperative status to 84.4 ± 12.3 at final follow-up. The mean donor age was 48.7 ± 8.4 years; a significant difference in Lysholm score was noted between patients that received an allograft with a donor age <45 years (14 patients; 27%) and those receiving an allograft with a donor age ≥45 years (38; 73%) (89.5 ± 3.2 vs. 80.1 ± 11.1, respectively; p  = 0.0469). The multiple regression model showed the donor age, the final follow-up, and the preoperative Lysholm score as significant predictors of postoperative Lysholm score ( p  < 0.0002). Conclusion  Donor age of nonirradiated Achilles tendon allograft influenced the mid-term results of revision ACL reconstruction, thus advising the use of grafts from young donors. Level of Evidence  Level III, retrospective comparative study. PMID:29675501

  1. Validation of ISTTOK Plasma Position Controller

    International Nuclear Information System (INIS)

    Valcarcel, D. F.; Carvalho, I. S.; Carvalho, B. B.; Fernandes, H.; Silva, C.; Duarte, P.; Duarte, A.; Carvalho, P. J.; Pereira, T.

    2008-01-01

    Active control of plasma position on the ISTTOK tokamak is of extreme importance due to the inherent instability caused by an unfavourable curvature of the external equilibrium magnetic field. The consequences of this instability can be suppressed by applying a dynamic equilibrium field. A digital real-time plasma position control system for ISTTOK has been developed to perform this task. This system uses magnetic measurements to determine the plasma position and feeds the control signal to power supplies that generate the equilibrium fields. After commissioning, the results obtained have shown some discrepancies between the magnetic plasma position reconstruction and several other diagnostics, such as tomography. This discrepancy at some extent is due to the effect of the external magnetic fields on the poloidal magnetic measurements. This work presents a study that addresses this issue. In a future work it will lead to the development of a corrected plasma position algorithm, aiming at obtaining improved performance of plasma discharges and controlled plasma column displacements

  2. Plasma position control on Alcator C

    International Nuclear Information System (INIS)

    Pribyl, P.A.

    1981-05-01

    The Alcator C MHD equilibrium is investigated from the standpoint of determining the plasma position. A review of equilibrium theory is presented, indicating that the central flux surfaces of the plasma should be displaced about 1 to 2 cm from the outermost. Further, the plasma should have a slightly noncircular cross-section. A comparison is made between the observed and predicted profiles. Flux loops sensitive to plasma position generate the error signal for the feedback control circuit. This measurement agrees with other position-sensitive diagnostics, such as limiter heating, and centroids of density, soft x-ray, and electron cyclotron emission. A linear model is developed for the position control feedback system, including the vertical field SCR supply, plasma, and feedback electronics. Operation of the control system agrees well with that predicted by the model, with acceptable plasma position being maintained for the duration of the discharge. The feedback control system is in daily use for Alcator C runs

  3. SU-E-T-507: Interfractional Variation of Fiducial Marker Position During HDR Brachytherapy with Cervical Interstitial Needle Template

    Energy Technology Data Exchange (ETDEWEB)

    Shen, S; Kim, R; Benhabib, S; Araujo, J; Burnett, L; Duan, J; Popple, R; Wu, X; Cardan, R; Brezovich, I [UniversityAlabama Birmingham, Birmingham, AL (United Kingdom)

    2014-06-01

    Purpose: HDR brachytherapy using interstitial needle template for cervical cancer is commonly delivered in 4-5 fractions. Routine verification of needle positions before each fraction is often based on radiographic imaging of implanted fiducial markers. The current study evaluated interfractional displacement of implanted fiducial markers using CT images. Methods: 9 sequential patients with cervical interstitial needle implants were evaluated. The superior and inferior borders of the target volumes were defined by fiducial markers in planning CT. The implant position was verified with kV orthogonal images before each fraction. A second CT was acquired prior 3rd fraction (one or 2 days post planning CT). Distances from inferior and superior fiducial markers to pubic symphysis plane (perpendicular to vaginal obtulator)were measured. Distance from needle tip of a reference needle (next to the inferior marker) to the pubic symphysis plane was also determined. The difference in fiducial marker distance or needle tip distance between planning CT and CT prior 3rd fraction were measured to assess markers migration and needle displacement. Results: The mean inferior marker displacement was 4.5 mm and ranged 0.9 to 11.3 mm. The mean superior marker displacement was 2.7 mm and ranged 0 to 10.4 mm. There was a good association between inferior and superior marker displacement (r=0.95). Mean averaged inferior and superior marker displacement was 3.3 mm and ranged from 0.1 to 10.9 mm, with a standard deviation of 3.2 mm. The mean needle displacement was 5.6 mm and ranged 0.2 to 15.6 mm. Needle displacements were reduced (p<0.05) after adjusting according to needle-to-fiducials distance. Conclusion: There were small fiducial marker displacements between HDR fractions. Our study suggests a target margin of 9.7 mm to cover interfractional marker displacements (in 95% cases) for pretreatment verification based on radiographic imaging.

  4. Control of plasma position in the CASTOR tokamak

    International Nuclear Information System (INIS)

    Valovic, M.

    1988-11-01

    A simple servo-system designed for plasma position control in the CASTOR tokamak is described. Both radial and vertical plasma displacements were minimized using two servo-loops consisting of detection coils, a conventional electric controller and an amplifier operated as an unipolar voltage-controlled current source. To ensure the optimum conditions in the start-up phase of the discharge, currents in the servo-systems were externally preprogrammed. The prescribed plasma position was maintained with the accuracy of 3 mm. The feedback control improves plasma parameters, e.g. it removes the positional disruption at the end of the tokamak discharge. (J.U.). 4 figs., 3 refs

  5. Rotational displacement skills in rhesus macaques (Macaca mulatta).

    Science.gov (United States)

    Hughes, Kelly D; Santos, Laurie R

    2012-11-01

    Rotational displacement tasks, in which participants must track an object at a hiding location within an array while the array rotates, exhibit a puzzling developmental pattern in humans. Human children take an unusually long time to master this task and tend to solve rotational problems through the use of nongeometric features or landmarks as opposed to other kinds of spatial cues. We investigated whether these developmental characteristics are unique to humans by testing rotational displacement skills in a monkey species, the rhesus macaque (Macaca mulatta), using a looking-time method. Monkeys first saw food hidden in two differently colored boxes within an array. The array was then rotated 180° and the boxes reopened to reveal the food in an expected or unexpected location. Our first two experiments explored the developmental time-course of performance on this rotational displacement task. We found that adult macaques looked longer at the unexpected event, but such performance was not mirrored in younger-aged macaques. In a third study, we systematically varied featural information and visible access to the array to investigate which strategies adult macaques used in solving rotational displacements. Our results show that adult macaques need both sets of information to solve the task. Taken together, these results suggest both similarities and differences in mechanisms by which human and nonhuman primates develop this spatial skill.

  6. Adjusting the displaced tip of peripherally inserted central catheter under DSA guidance

    International Nuclear Information System (INIS)

    Mao Yanjun; Dong Huijuan; Zhang Lingjuan; Li Hongmei; Xu Lianqin

    2009-01-01

    Objective: To explore a new method to adjust the displaced tip of peripherally inserted central catheter (PICC) under DSA guidance. Methods: Under DSA guidance, the displaced tip of PICC was repositioned to the ideal junction area of superior vena cava with right atrium with proper manipulation. Results: Under DSA guidance, the displaced tip of PICC was successfully corrected in 13 cases. The mean operative time was 15.53 minutes, which was markedly shorter than that needed by blind adjusting beside the bed. Conclusion: The displacement of PICC tip is a common occurrence, which is hard to be avoided. Under DSA guidance, the adjusting manipulation of the displaced PICC tip is safe and time-saving with high successful rate. It is worth popularizing this technique in clinical practice. (authors)

  7. Airflow and Contaminant Distribution in Hospital Wards with a Displacement Ventililation System

    DEFF Research Database (Denmark)

    Qian, H.; Nielsen, Peter Vilhelm; Li, Y.

    2004-01-01

    Airflow and Contaminant Distribution in Hospital Wards with a Displacement Ventilalation System. The 2nd International Conference on Build Environment and Public Health, BEPH 2004, Shenzhen , China . ABSTRACT Displacement ventilation has not been considered to be an applicable system for hospital...... to accurately predict three-dimensional distribution of air velocity, temperature, and contaminant concentration in the ward. Indoor airflow in a displacement ventilation system involves a combination of different flow streams such as the gravity currents and thermal plumes. It is important to choose...... ventilation system in hospital wards. It is for this purpose that we study the performance of displacement ventilation in hospital wards as one of the steps to optimize the ventilation design. When the prospect of applying displacement ventilation system in a hospital ward is examined, it should be necessary...

  8. Needle displacement during HDR brachytherapy in the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Damore, Steven J.; Syed, A.M. Nisar; Puthawala, Ajmel A.; Sharma, Anil

    2000-01-01

    Purpose: We used clinical patient data to examine implant displacement between high dose rate (HDR) brachytherapy fractions for prostate cancer to determine its impact on treatment delivery. Materials and Methods: We analyzed the verification films taken prior to each fraction for 96 consecutive patients treated with HDR brachytherapy boosts as part of their radiation therapy for definitive treatment of organ-confined prostate cancer at our institution. Patients were treated with 18-24 Gy in 4 fractions of HDR delivered in 40 hours followed by 36-39.6 Gy external beam radiation to the prostate. We determined the mean and maximum displacement distances of marker seeds placed in the prostate and of the implanted needles between HDR fractions. Results: Mean and maximum displacement distances between fractions were documented up to 7.6 mm and 28.5 mm, respectively, for the implant needles and 3.6 mm and 11.4 mm, respectively, for the gold marker seeds. All displacement of implant needles occurred in the caudal direction. At least 1 cm caudal displacement of needles occurred prior to 15.5% all fractions. Manual adjustment of needles was required prior to 15% of fractions, and adjustment of the CLP only was required in 24%. Most of the displacement for both the marker seeds and needles occurred between the first and second fractions. Conclusions: There is significant caudal displacement of interstitial implant needles between HDR fractions in our prostate cancer patients. Obtaining verification films and making adjustments in the treatment volume prior to each fraction is necessary to avoid significant inaccuracies in treatment delivery

  9. Occupant Kinematics in Simulated Autonomous Driving Vehicle Collisions: Influence of Seating Position, Direction and Angle.

    Science.gov (United States)

    Kitagawa, Yuichi; Hayashi, Shigeki; Yamada, Katsunori; Gotoh, Mitsuaki

    2017-11-01

    This two-part study analyzed occupant kinematics in simulated collisions of future automated driving vehicles in terms of seating configuration. In part one, a frontal collision was simulated with four occupants with the front seats reversed. The left front seat occupant was unbelted while the others were belted. In part two of the study, occupant restraint was examined in various seating configurations using a single seat model with a three-point seatbelt. The seat direction with respect to impact was considered as forward, rearward, and lateral facing in 45 degree increments. The effect of seat recline was also studied in the forward-facing and rear-facing cases by assuming three positions: driving position, resting position and relaxed position. Occupants were represented by human body finite element models. The results of part one showed that the front seat (rear-facing) occupants were restrained by the seatback, resulting in T1 forward displacement less than 100 mm; the rear seat occupants were restrained by the seatbelt resulting larger T1 forward displacement more than 500 mm. The results of the part two showed the directional dependence of occupant restraint. Greater T1 displacements were observed when the occupant faced lateral or front oblique. However, the seatbelt provided some restraint in all directions considered. The seatback generated contact force to the occupant when it was in the impact direction, including the lateral directions. The relaxed position allowed increased excursion compared to the driving position when the occupant faced rearward, but the magnitude of this increase was lower with lower impact speed.

  10. Crack displacement sensing and measurement in concrete using circular grating moire fringes and pattern matching

    Science.gov (United States)

    Chan, H. M.; Yen, K. S.; Ratnam, M. M.

    2008-09-01

    The moire method has been extensively studied in the past and applied in various engineering applications. Several techniques are available for generating the moire fringes in these applications, which include moire interferometry, projection moire, shadow moire, moire deflectometry etc. Most of these methods use the superposition of linear gratings to generate the moire patterns. The use of non-linear gratings, such as circular, radial and elongated gratings has received less attention from the research community. The potential of non-linear gratings in engineering measurement has been realized in a limited number of applications, such as rotation measurement, measurement of linear displacement, measurement of expansion coefficients of materials and measurement of strain distribution. In this work, circular gratings of different pitch were applied to the sensing and measurement of crack displacement in concrete structures. Gratings of pitch 0.50 mm and 0.55 mm were generated using computer software and attached to two overlapping acrylic plates that were bonded to either side of the crack. The resulting moire patterns were captured using a standard digital camera and compared with a set of reference patterns generated using a precision positioning stage. Using several image pre-processing stages, such as filtering and morphological operations, and pattern matching the magnitude displacements along two orthogonal axes can be detected with a resolution of 0.05 mm.

  11. Research on Dynamic Parameters and Position Accuracy of Pneumatics Muscles

    Directory of Open Access Journals (Sweden)

    Edvard Sadovskij

    2012-12-01

    Full Text Available The article deals with pneumatic muscle MAS-20-200N-AA-MC-O, its dynamic properties and positioning accuracy as well as overviews experimental and theoretical works. The paper introduces the diagrams of vibration acceleration, discusses displacement dependence on pressure and load and presents a diagram of speed dependence on operating pressure. Vibroacceleration has been measured employing two accelerometers. Measurements have been carried out in three mutually perpendicular directions: x, y and z. The most important one is direction z, because this way the muscle performs a valuable displacement along the axis of the muscle, since this direction is the movement of the working muscle.Article in Lithuanian

  12. Research on Dynamic Parameters and Position Accuracy of Pneumatics Muscles

    Directory of Open Access Journals (Sweden)

    Edvard Sadovskij

    2013-02-01

    Full Text Available The article deals with pneumatic muscle MAS-20-200N-AA-MC-O, its dynamic properties and positioning accuracy as well as overviews experimental and theoretical works. The paper introduces the diagrams of vibration acceleration, discusses displacement dependence on pressure and load and presents a diagram of speed dependence on operating pressure. Vibroacceleration has been measured employing two accelerometers. Measurements have been carried out in three mutually perpendicular directions: x, y and z. The most important one is direction z, because this way the muscle performs a valuable displacement along the axis of the muscle, since this direction is the movement of the working muscle.Article in Lithuanian

  13. Forced migration and mental health: prolonged internal displacement, return migration and resilience.

    Science.gov (United States)

    Siriwardhana, Chesmal; Stewart, Robert

    2013-03-01

    Forced internal displacement has been rising steadily, mainly due to conflict. Many internally displaced people (IDP) experience prolonged displacement. Global research evidence suggests that many of these IDP are at high risk for developing mental disorders, adding weight to the global burden of disease. However, individual and community resilience may act as protective factors. Return migration may be an option for some IDP populations, especially when conflicts end, although return migration may itself be associated with worse mental health. Limited evidence is available on effects of resettlement or return migration following prolonged forced internal displacement on mental health. Also, the role of resilience factors remains to be clarified following situations of prolonged displacement. The public health impact of internal displacement is not clearly understood. Epidemiological and interventional research in IDP mental health needs to look beyond medicalised models and encompass broader social and cultural aspects. The resilience factor should be integrated and explored more in mental health research among IDP and a clearly focused multidisciplinary approach is advocated.

  14. Wrong vertex displacements due to Lee-Wick resonances at LHC

    International Nuclear Information System (INIS)

    Alvarez, E.; Schat, C.; Rold, L. da; Szynkman, A.

    2009-01-01

    We show how a resonance from the recently proposed Lee-Wick Standard Model could lead to wrong vertex displacements at LHCb. We study which could be the possible 'longest lived' Lee-Wick particle that could be created at LHC, and we study its possible decays and detections. We conclude that there is a region in the parameter space which would give wrong vertex displacements as a unique signature of the Lee-Wick Standard Model at LHCb. Further numerical simulation shows that LHC era could explore these wrong vertex displacements through Lee-Wick leptons below 500 GeV. (author)

  15. Dual-reflector configuration in varied line-space grating displacement sensor

    International Nuclear Information System (INIS)

    Liu Zhengkun; Xu Xiangdong; Fu Shaojun; Zhou Qin; Liu Bin

    2008-01-01

    A method to improve the accuracy of the wavelength encoding varied line-space grating displacement sensor is presented. Based on the detailed analysis of the measured displacement errors from the single-mirror configuration sensor, a dual-reflector configuration is used to replace the previous configuration, and greatly decreases its errors. Experiments are conducted in order to make comparison of the two configurations. The results show that the measured displacement error of the sensor with dual-reflector configuration is lower than 0.03 mm in full scale (0 to 50 mm), only about 10% of the sensor with single-mirror configuration

  16. Relation between anterior displacement of the temporomandibular joint disc and size of the condyle

    International Nuclear Information System (INIS)

    Ohgushi, Masatoshi; Kubota, Hisashi; Yamaguchi, Kouichi; Shibata, Takanori

    1996-01-01

    To elucidate the cause of anterior displacement of the disc, we evaluated the relation between anterior displacement and the size of the condyle from MR images in 301 patients (602 TMJs) with clinical diagnosis of internal derangement. We found that the size of condyles with anterior displacement of the disc was significantly smaller than that of condyles without anterior displacement. This result suggests that small condyles may give rise to anterior displacement of the disc. (author)

  17. Surgical treatment of patellofemoral instability using trochleoplasty or MPFL reconstruction: a systematic review.

    Science.gov (United States)

    Testa, Enrique Adrian; Camathias, Carlo; Amsler, Felix; Henle, Philipp; Friederich, Niklaus F; Hirschmann, Michael Tobias

    2017-08-01

    Trochleoplasty and reconstruction of the medial patellofemoral ligament (MPFL) are among the most commonly performed surgical treatments in patients with patellofemoral instability. The primary purpose of the study was to perform a systematic literature review on trochleoplasty in the treatment of patients with patellofemoral instability. The secondary purpose was to compare the outcomes with those seen in patients treated after reconstruction of the MPFL. A standardised search on search engines was performed. All observational and experimental studies dealing with trochleoplasty were then obtained and reviewed in a consensus meeting. Fifteen articles out of 1543 were included and analysed using the CASP appraisal scoring system. Twenty-five studies on MPFL reconstruction were obtained for comparison. The clinical and radiological outcomes were statistically analysed. Both treatment groups showed significant improvement in outcomes from pre- to post-operatively. The mean post-operative Kujala and the Lysholm scores significantly increased in both groups when compared to preoperatively (trochleoplasty group: Kujala 61.4-80.8 and Lysholm 55.5-78.5; MPFL group: Kujala 46.9-88.8 and Lysholm 59.9-91.1). Post-operatively a positive apprehension test was found in 20 and 8 % of the trochleoplasty and MPFL groups, respectively. No significant differences in redislocation (2 %) and subluxation (5-6 %) rates were found. This systematic review showed that both trochleoplasty and MPFL reconstruction are able to deliver good clinical outcomes with stable patellofemoral joints. III.

  18. Speed and Displacement Control System of Bearingless Brushless DC Motor Based on Improved Bacterial Foraging Algorithm

    Directory of Open Access Journals (Sweden)

    Diao Xiaoyan

    2016-01-01

    Full Text Available To solve the deficiencies of long optimization time and poor precision existing in conventional bacterial foraging algorithm (BFA in the process of parameter optimization, an improved bacterial foraging algorithm (IBFA is proposed and applied to speed and displacement control system of bearingless brushless DC (Bearingless BLDC motors. To begin with the fundamental principle of BFA, the proposed method is introduced and the individual intelligence is efficiently used in the process of parameter optimization, and then the working principle of bearingless BLDC motors is expounded. Finally, modeling and simulation of the speed and displacement control system of bearingless BLDC motors based on the IBFA are carried out by taking the software of MATLAB/Simulink as a platform. Simulation results show that, speed overshoot, torque ripple and rotor position oscillation are dramatically reduced, thus the proposed method has good application prospects in the field of bearingless motors.

  19. Off-Axis Gaussian Beams with Random Displacement in Atmospheric Turbulence

    Directory of Open Access Journals (Sweden)

    Yahya Baykal

    2006-10-01

    Full Text Available Our recent work in which we study the propagation of the general Hermite-sinusoidal-Gaussian laser beams in wireless broadband access telecommunication systems is elaborated in this paper to cover the special case of an off-axis Gaussian beam. We mainly investigate the propagation characteristics in atmospheric turbulence of an off-axis Gaussian beam possessing Gaussian distributed random displacement parameters. Our interest is to search for different types of laser beams that will improve the performance of a wireless broadband access system when atmospheric turbulence is considered. Our formulation is based on the basic solution of the second order mutual coherence function evaluated at the receiver plane. For fixed turbulence strength, the coherence length calculated at the receiver plane is found to decrease as the variance of the random displacement is increased. It is shown that as the turbulence becomes stronger, coherence lengths due to off-axis Gaussian beams tend to approach the same value, irrespective of the variance of the random displacement. As expected, the beam spreading is found to be pronounced for larger variance of displacement parameter. Average intensity profiles when atmospheric turbulence is present are plotted for different values of the variance of the random displacement parameter of the off-axis Gaussian beam.

  20. Women's sexual and reproductive health in post-socialist Georgia: does internal displacement matter?

    Science.gov (United States)

    Doliashvili, Khatuna; Buckley, Cynthia J

    2008-03-01

    Persons displaced by armed conflicts, natural disasters or other events are at increased risk for health problems. The Republic of Georgia has a substantial population of internally displaced women who may face elevated risks of STIs and pelvic inflammatory disease (PID). The 1999 Georgia Reproductive Health Survey was used to examine the prevalence of self-reported STI and PID diagnoses among displaced and nondisplaced sexually experienced women. Multivariate analyses were conducted to determine whether displacement is associated with STI and PID risk, and whether the behavioral and socioeconomic factors associated with these diagnoses differ between internally displaced women and the general population. In models that controlled for behavioral factors only, displacement was associated with elevated odds of PID diagnosis (odds ratio, 1.3), but the relationship was only marginally significant when socioeconomic factors were added (1.3). Displacement was not associated with STI diagnosis. The factors associated with STI and PID diagnoses among displaced women generally differed from those in the general population, but access to medical care and previous STI diagnosis were associated with PID diagnosis in both groups. Among nondisplaced women, residing in the capital city was associated with increased odds of STI diagnosis (2.2) but reduced odds of PID diagnosis (0.8). These findings highlight the importance of displacement status in determining a woman's reproductive health risks, and underscore the complex relationships between behavioral and socioeconomic variables and the elevation of STI and PID risk.

  1. Analysis of displacement damage and defect production under cascade damage conditions

    DEFF Research Database (Denmark)

    Zinkle, S.J.; Singh, B.N.

    1993-01-01

    and residual defect production must be treated separately. An evaluation of experimental and computer defect production studies indicates that the overall fraction of defects surviving correlated annihilation in an energetic displacement cascade in copper decreases from about 30% of the Norgett......-Robinson-Torrens (NRT) calculated displacements at 4 K to about 10% of the NRT displacements at 300 K. Due to differences in the thermal stability of vacancy versus interstitial clusters, the fractions of freely migrating defects available for inducing microstructural changes at elevated temperatures may be higher...... for vacancies than for interstitials. The available evidence suggests that the fraction of freely migrating vacancies at temperatures relevant for void swelling in copper is greater than or similar to 5% of the calculated NRT displacements....

  2. Comparing Teaching Approaches About Maxwell's Displacement Current

    Science.gov (United States)

    Karam, Ricardo; Coimbra, Debora; Pietrocola, Maurício

    2014-08-01

    Due to its fundamental role for the consolidation of Maxwell's equations, the displacement current is one of the most important topics of any introductory course on electromagnetism. Moreover, this episode is widely used by historians and philosophers of science as a case study to investigate several issues (e.g. the theory-experiment relationship). Despite the consensus among physics educators concerning the relevance of the topic, there are many possible ways to interpret and justify the need for the displacement current term. With the goal of understanding the didactical transposition of this topic more deeply, we investigate three of its domains: (1) The historical development of Maxwell's reasoning; (2) Different approaches to justify the term insertion in physics textbooks; and (3) Four lectures devoted to introduce the topic in undergraduate level given by four different professors. By reflecting on the differences between these three domains, significant evidence for the knowledge transformation caused by the didactization of this episode is provided. The main purpose of this comparative analysis is to assist physics educators in developing an epistemological surveillance regarding the teaching and learning of the displacement current.

  3. Improved multiple displacement amplification (iMDA) and ultraclean reagents.

    Science.gov (United States)

    Motley, S Timothy; Picuri, John M; Crowder, Chris D; Minich, Jeremiah J; Hofstadler, Steven A; Eshoo, Mark W

    2014-06-06

    Next-generation sequencing sample preparation requires nanogram to microgram quantities of DNA; however, many relevant samples are comprised of only a few cells. Genomic analysis of these samples requires a whole genome amplification method that is unbiased and free of exogenous DNA contamination. To address these challenges we have developed protocols for the production of DNA-free consumables including reagents and have improved upon multiple displacement amplification (iMDA). A specialized ethylene oxide treatment was developed that renders free DNA and DNA present within Gram positive bacterial cells undetectable by qPCR. To reduce DNA contamination in amplification reagents, a combination of ion exchange chromatography, filtration, and lot testing protocols were developed. Our multiple displacement amplification protocol employs a second strand-displacing DNA polymerase, improved buffers, improved reaction conditions and DNA free reagents. The iMDA protocol, when used in combination with DNA-free laboratory consumables and reagents, significantly improved efficiency and accuracy of amplification and sequencing of specimens with moderate to low levels of DNA. The sensitivity and specificity of sequencing of amplified DNA prepared using iMDA was compared to that of DNA obtained with two commercial whole genome amplification kits using 10 fg (~1-2 bacterial cells worth) of bacterial genomic DNA as a template. Analysis showed >99% of the iMDA reads mapped to the template organism whereas only 0.02% of the reads from the commercial kits mapped to the template. To assess the ability of iMDA to achieve balanced genomic coverage, a non-stochastic amount of bacterial genomic DNA (1 pg) was amplified and sequenced, and data obtained were compared to sequencing data obtained directly from genomic DNA. The iMDA DNA and genomic DNA sequencing had comparable coverage 99.98% of the reference genome at ≥1X coverage and 99.9% at ≥5X coverage while maintaining both balance

  4. Non-uniform-tilt-modulated fiber Bragg grating for temperature-immune micro-displacement measurement

    International Nuclear Information System (INIS)

    Guo, Tuan; Chen, Chengkun; Albert, Jacques

    2009-01-01

    Temperature-immune micro-displacement measurement is demonstrated by using a Gaussian-chirped tilted fiber Bragg grating (TFBG). The internal tilt angles of the sensing TFBG are effectively modulated via a displacement-induced Gaussian-strain-gradient along the specially designed bending cantilever beam. The phase mismatch between different effective pitches and tilt angles weakens the core-to-cladding mode coupling as the beam is displaced. While the power of the ghost mode resonance in transmission shows a strong sensitivity to the displacement, it is immune from spatially uniform temperature changes. Ghost-power-referenced displacement measurement and temperature-insensitive property are experimentally achieved for this cost-effective sensing device

  5. Potential displacement of petroleum imports by solar energy technologies

    Energy Technology Data Exchange (ETDEWEB)

    DeLeon, P.; Jackson, B.L.; McNown, R.F.; Mahrenholz, G.J.

    1980-05-01

    The United States currently imports close to half of its petroleum requirements. This report delineates the economic, social, and political costs of such a foreign oil dependency. These costs are often intangible, but combined they clearly constitute a greater price for imported petroleum than the strictly economic cost. If we can assume that imported oil imposes significant socioeconomic costs upon the American economy and society, one way to reduce these costs is to develop alternative, domestic energy sources - such as solar energy technologies - which can displace foreign petroleum. The second half of this report estimates that by the year 2000, solar energy technologies can displace 3.6 quads of petroleum. This figure includes solar energy applications in utilities, industrial and agricultural process heat, and transportation. The estimate can be treated as a lower bound; if the United States were to achieve the proposed goal of 20 quads by 2000, the amount of displaced oil probably would be greater. Although all the displaced oil would not be imported, the reduction in imported petroleum would relieve many of the conditions that increase the present cost of foreign oil to the American consumer.

  6. Multi-link laser interferometry architecture for interspacecraft displacement metrology

    Science.gov (United States)

    Francis, Samuel P.; Lam, Timothy T.-Y.; McClelland, David E.; Shaddock, Daniel A.

    2018-03-01

    Targeting a future Gravity Recovery and Climate Experiment (GRACE) mission, we present a new laser interferometry architecture that can be used to recover the displacement between two spacecraft from multiple interspacecraft measurements. We show it is possible to recover the displacement between the spacecraft centers of mass in post-processing by forming linear combinations of multiple, spatially offset, interspacecraft measurements. By canceling measurement error due to angular misalignment of the spacecraft, we remove the need for precise placement or alignment of the interferometer, potentially simplifying spacecraft integration. To realize this multi-link architecture, we propose an all-fiber interferometer, removing the need for any ultrastable optical components such as the GRACE Follow-On mission's triple mirror assembly. Using digitally enhanced heterodyne interferometry, the number of links is readily scalable, adding redundancy to our measurement. We present the concept, an example multi-link implementation and the signal processing required to recover the center of mass displacement from multiple link measurements. Finally, in a simulation, we analyze the limiting noise sources in a 9 link interferometer and ultimately show we can recover the 80 {nm}/√{ {Hz}} displacement sensitivity required by the GRACE Follow-On laser ranging interferometer.

  7. Development of a High Precision Displacement Measurement System by Fusing a Low Cost RTK-GPS Sensor and a Force Feedback Accelerometer for Infrastructure Monitoring

    Directory of Open Access Journals (Sweden)

    Gunhee Koo

    2017-11-01

    Full Text Available A displacement measurement system fusing a low cost real-time kinematic global positioning system (RTK-GPS receiver and a force feedback accelerometer is proposed for infrastructure monitoring. The proposed system is composed of a sensor module, a base module and a computation module. The sensor module consists of a RTK-GPS rover and a force feedback accelerometer, and is installed on a target structure like conventional RTK-GPS sensors. The base module is placed on a rigid ground away from the target structure similar to conventional RTK-GPS bases, and transmits observation messages to the sensor module. Then, the initial acceleration, velocity and displacement responses measured by the sensor module are transmitted to the computation module located at a central monitoring facility. Finally, high precision and high sampling rate displacement, velocity, and acceleration are estimated by fusing the acceleration from the accelerometer, the velocity from the GPS rover, and the displacement from RTK-GPS. Note that the proposed displacement measurement system can measure 3-axis acceleration, velocity as well as displacement in real time. In terms of displacement, the proposed measurement system can estimate dynamic and pseudo-static displacement with a root-mean-square error of 2 mm and a sampling rate of up to 100 Hz. The performance of the proposed system is validated under sinusoidal, random and steady-state vibrations. Field tests were performed on the Yeongjong Grand Bridge and Yi Sun-sin Bridge in Korea, and the Xihoumen Bridge in China to compare the performance of the proposed system with a commercial RTK-GPS sensor and other data fusion techniques.

  8. Constant displacement rate testing at elevated temperatures

    International Nuclear Information System (INIS)

    Pepe, J.J.; Gonyea, D.C.

    1989-01-01

    A short time test has been developed which is capable of determining the long time notch sensitivity tendencies of CrMoV rotor forging materials. This test is based on Constant Displacement Rate (CDR) testing of a specific notch bar specimen at 1200 0 F at 2 mils/in/hour displacement rate. These data were correlated to conventional smooth and notch bar rupture behavior for a series of CrMoV materials with varying long time ductility tendencies. The purpose of this paper is to describe the details of this new test procedure and some of the relevant mechanics of material information generated during its development

  9. Twiddler-syndrom er en årsag til pacemaker elektrode displacering

    DEFF Research Database (Denmark)

    Grønbech, Keea Treu; Hansen, Michael Gilså

    2013-01-01

    Twiddler's syndrome is a rare cause of pacemaker electrode displacement. The displacement is caused by the patient's manipulation with the pacemaker, so the electrode is retracted. We describe a case of a 79-year-old overweight woman with a known psychiatric anamnesis, who was admitted twice...

  10. Influence of stability of polymer surfactant on oil displacement mechanism

    Science.gov (United States)

    Liu, Li; Li, Chengliang; Pi, Yanming; Wu, Di; He, Ying; Geng, Liang

    2018-02-01

    At present, most of the oilfields of China have entered the late stage of high water-cut development, and three oil recovery technique has become the leading technology for improving oil recovery. With the improvement of three oil recovery techniques, the polymer surfactant flooding technology has been widely promoted in oil fields in recent years. But in the actual field experiment, it has been found that the polymer surfactant has chromatographic separation at the extraction end, which indicates that the property of the polymer surfactant has changed during the displacement process. At present, there was few literature about how the stability of polymer surfactant affects the oil displacement mechanism. This paper used HuaDing-I polymer surfactant to conduct a micro photolithography glass flooding experiment, and then compared the oil displacement law of polymer surfactant before and after static setting. Finally, the influence law of stability of polymer surfactant on the oil displacement mechanism is obtained by comprehensive analysis.

  11. Effect of displacement on resistance and capacitance of polyaniline film

    International Nuclear Information System (INIS)

    Karimov, Khasan Sanginovich; Saeed, Muhammad Tariq; Khalid, Fazal Ahmad; Moiz, Syed Abdul

    2011-01-01

    This paper investigates the properties of displacement sensors based on polyaniline (PANI) films. About 1 wt% of PANI micropowder is mixed and stirred in a solution of 90 wt% water and 10 wt% alcohol at room temperature. The films of PANI are deposited from solution by drop-casting on Ag electrodes, which are preliminary deposited on glass substrates. The thicknesses of the PANI films are in the range of 20 μm–80 μm. A displacement sensor with polyaniline film as an active material is designed and fabricated. The investigations showed that, on average, the AC resistance of the sensor decreases by 2 times and the capacitance accordingly increases by 1.6 times as the displacement changes in the range of 0 mm–0.5 mm. The polyaniline is the only active material of the displacement sensor. The resistance and capacitance of the PANI changes under the pressure of spring and elastic rubber, and this pressure is created by the downward movement of the micrometer. (general)

  12. A randomized clinical study of two interceptive approaches to palatally displaced canines.

    Science.gov (United States)

    Baccetti, Tiziano; Leonardi, Maria; Armi, Pamela

    2008-08-01

    This study evaluated the effectiveness of two interceptive approaches to palatally displaced canines (PDC), i.e. extraction of the primary canines alone or in association with the use of a cervical-pull headgear. The randomized prospective design comprised 75 subjects with PDC (92 maxillary canines) who were randomly assigned to three groups: extraction of the primary canine only (EG), extraction of the primary canine and cervical-pull headgear (EHG), and an untreated control group (CG). Panoramic radiographs were evaluated at the time of initial observation (T1) and after an average period of 18 months (T2). At T2, an evaluation of the success of canine eruption was undertaken. Between-group statistical comparisons, Kruskal-Wallis test with Bonferroni correction, were performed on the T1-T2 changes of the diagnostic parameters on panoramic radiographs and the prevalence rates of success in canine eruption. A superimposition study on lateral cephalograms at T1 and T2 was carried out to evaluate the changes in the sagittal position of the upper molars in the three groups. The removal of the primary canine as an isolated measure to intercept palatal displacement of maxillary canines showed a success rate of 65.2 per cent, which was significantly greater than that in the untreated controls (36 per cent). The additional use of a headgear resulted in successful eruption in 87.5 per cent of the subjects, with a significant improvement in the measurements for intraosseous canine position. The cephalometric superimposition study showed a significant mesial movement of the upper first molars in the CG and EG when compared with the EHG.

  13. Semen Displacement as a Sperm Competition Strategy in Humans

    Directory of Open Access Journals (Sweden)

    Gordon G. Gallup

    2004-01-01

    Full Text Available We examine some of the implications of the possibility that the human penis may have evolved to compete with sperm from other males by displacing rival semen from the cervical end of the vagina prior to ejaculation. The semen displacement hypothesis integrates considerable information about genital morphology and human reproductive behavior, and can be used to generate a number of interesting predictions.

  14. Meta-analysis of greenhouse gas displacement factors of wood product substitution

    International Nuclear Information System (INIS)

    Sathre, Roger; O'Connor, Jennifer

    2010-01-01

    A displacement factor can express the efficiency of using biomass to reduce net greenhouse gas (GHG) emission, by quantifying the amount of emission reduction achieved per unit of wood use. Here we integrate data from 21 different international studies in a meta-analysis of the displacement factors of wood products substituted in place of non-wood materials. We calculate the displacement factors in consistent units of tons of carbon (tC) of emission reduction per tC in wood product. The displacement factors range from a low of -2.3 to a high of 15, with most lying in the range of 1.0 to 3.0. The average displacement factor value is 2.1, meaning that for each tC in wood products substituted in place of non-wood products, there occurs an average GHG emission reduction of approximately 2.1 tC. Expressed in other units, this value corresponds to roughly 3.9 t CO 2 eq emission reduction per ton of dry wood used. The few cases of negative displacement factors are the result of worst-case scenarios that are unrealistic in current practice. This meta-analysis quantifies the range of GHG benefits of wood substitution, and provides a clear climate rationale for increasing wood substitution in place of other products, provided that forests are sustainably managed and that wood residues are used responsibly.

  15. Meta-analysis of greenhouse gas displacement factors of wood product substitution

    Energy Technology Data Exchange (ETDEWEB)

    Sathre, Roger [Ecotechnology, Mid Sweden University, 83125 Ostersund (Sweden); O' Connor, Jennifer [FPInnovations-Forintek, Vancouver, BC, Canada V6T 1W5 (Canada)

    2010-04-15

    A displacement factor can express the efficiency of using biomass to reduce net greenhouse gas (GHG) emission, by quantifying the amount of emission reduction achieved per unit of wood use. Here we integrate data from 21 different international studies in a meta-analysis of the displacement factors of wood products substituted in place of non-wood materials. We calculate the displacement factors in consistent units of tons of carbon (tC) of emission reduction per tC in wood product. The displacement factors range from a low of -2.3 to a high of 15, with most lying in the range of 1.0 to 3.0. The average displacement factor value is 2.1, meaning that for each tC in wood products substituted in place of non-wood products, there occurs an average GHG emission reduction of approximately 2.1 tC. Expressed in other units, this value corresponds to roughly 3.9 t CO{sub 2} eq emission reduction per ton of dry wood used. The few cases of negative displacement factors are the result of worst-case scenarios that are unrealistic in current practice. This meta-analysis quantifies the range of GHG benefits of wood substitution, and provides a clear climate rationale for increasing wood substitution in place of other products, provided that forests are sustainably managed and that wood residues are used responsibly.

  16. MOLECULAR DYNAMICS SIMULATIONS OF DISPLACEMENT CASCADES IN MOLYBDENUM

    International Nuclear Information System (INIS)

    Smith, Richard Whiting

    2003-01-01

    Molecular dynamics calculations have been employed to simulate displacement cascades in neutron irradiated Mo. A total of 90 simulations were conducted for PKA energies between 1 and 40 keV and temperatures from 298 to 923K. The results suggest very little effect of temperature on final defect count and configuration, but do display a temperature effect on peak defect generation prior to cascade collapse. Cascade efficiency, relative to the NRT model, is computed to lie between 1/4 and 1/3 in agreement with simulations performed on previous systems. There is a tendency for both interstitials and vacancies to cluster together following cascade collapse producing vacancy rich regions surrounded by interstitials. Although coming to rest in close proximity, the point defects comprising the clusters generally do not lie within the nearest neighbor positions of one another, except for the formation of dumbbell di-interstitials. Cascades produced at higher PKA energies (20 or 40 keV) exhibit the formation of subcascades

  17. Characterization of damaged composite laminates by an optical measurement of the displacement field

    International Nuclear Information System (INIS)

    Loukil, M S; Ayadi, Z; Varna, J

    2012-01-01

    The degradation of the elastic properties of composite laminates with intralaminar cracks is caused by reduced stress in the damaged layer which is mainly due to two parameters: the crack opening displacement (COD) and the crack sliding displacement (CSD). In this paper these parameters are measured experimentally providing laminate stiffness reduction models with valuable information for validation of used assumptions and for defining limits of their application. In particular, the displacement field on the edges of a [0/ +70 4 / −70 4 ] s glass fiber/epoxy laminate specimens with multiple intralaminar cracks is studied and the COD and CSD dependence on the applied mechanical load is measured. The specimen full-field displacement measurement is carried out using ESPI (Electronic Speckle Pattern Interferometry). By studying the displacement discontinuities, the crack face displacements were measured. A comparison between the COD and the CSD (for the same crack) is performed.

  18. Analysis and experiments of a novel and compact 3-DOF precision positioning platform

    International Nuclear Information System (INIS)

    Huang, Hu; Zhao, Hongwei; Fan, Zunqiang; Zhang, Hui; Ma, Zhichao; Yang, Zhaojun

    2013-01-01

    A novel 3-DOF precision positioning platform with dimensions of 48 mm X 50 mm X 35 mm was designed by integrating piezo actuators and flexure hinges. The platform has a compact structure but it can do high precision positioning in three axes. The dynamic model of the platform in a single direction was established. Stiffness of the flexure hinges and modal characteristics of the flexure hinge mechanism were analyzed by the finite element method. Output displacements of the platform along three axes were forecasted via stiffness analysis. Output performance of the platform in x and y axes with open-loop control as well as the z-axis with closed-loop control was tested and discussed. The preliminary application of the platform in the field of nanoindentation indicates that the designed platform works well during nanoindentation tests, and the closed-loop control ensures the linear displacement output. With suitable control, the platform has the potential to realize different positioning functions under various working conditions.

  19. Displacement of carbon-14 labelled amino acids from leaves

    International Nuclear Information System (INIS)

    Schiller, R.

    1973-01-01

    The displacement of amino acids from nature leaves was investigated. The amino acids (Ala, Asn, Asp, Glu, Gln, Val, Leu, Lys, Ser, Pro) were applied on the leaves in L-form, uniformly labelled with 14 C, and the type and direction of displacement have been observed. Most of the studies have been carried out on bush beans aged 3 to 4 weeks. The experiments were carried out in climatic chambers; in one case, barley plants just reaching maturity were used. In order to find out whether the applied amino acids were also displaced in their original form, freeze-dried plants were extracted and the 14 C activity of the various fraction was determined. The radioactivity of some free amino acids was determined after two-dimensional separation by thin film chromatography. (orig./HK) [de

  20. Design Method for Fast Switching Seat Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    corresponding to the piston movement, which has been shown to facilitate superior part load efficiency combined with high bandwidth compared to traditional displacement machines. However, DD machines need fast switching on-off valves with low pressure loss for efficient operation, especially in fast rotating......Digital Displacement (DD) machines are upcoming technology where the displacement of each pressure chamber is controlled electronically by use of two fast switching seat valves. The effective displacement and operation type (pumping/motoring) may be controlled by manipulating the seat valves...... method for DD seat valves are presented, taking into account the significant aspects related to obtaining efficient DD valves with basis in a given DD machine specifications. The seat area is minimized and the stroke length is minimized to obtain fast switching times while considering the pressure loss...

  1. Work-family conflict, emotional exhaustion, and displaced aggression toward others: the moderating roles of workplace interpersonal conflict and perceived managerial family support.

    Science.gov (United States)

    Liu, Yihao; Wang, Mo; Chang, Chu-Hsiang; Shi, Junqi; Zhou, Le; Shao, Ruodan

    2015-05-01

    Taking a resource-based self-regulation perspective, this study examined afternoon emotional exhaustion as a mediator linking the within-person relations between morning work-family conflict and later employee displaced aggression in the work and family domains. In addition, it examined resource-related contextual factors as moderators of these relations. The theoretical model was tested using daily diary data from 125 employees. Data were collected at 4 time points during each workday for 3 consecutive weeks. Multilevel modeling analysis showed that morning family-to-work conflict was positively related to afternoon emotional exhaustion, which in turn predicted displaced aggression toward supervisors and coworkers in the afternoon and displaced aggression toward family members in the evening. In addition, morning workplace interpersonal conflict exacerbated the impact of morning work-to-family conflict on afternoon emotional exhaustion, whereas perceived managerial family support alleviated the impact of morning family-to-work conflict on afternoon emotional exhaustion. These findings indicate the importance of adopting a self-regulation perspective to understand work-family conflict at work and its consequences (i.e., displaced aggression) in both work and family domains. (c) 2015 APA, all rights reserved.

  2. Prismatic displacement effect of progressive multifocal glasses on reaction time and accuracy in elderly people

    Directory of Open Access Journals (Sweden)

    Ellison AC

    2014-05-01

    Full Text Available Ashton C Ellison, A John Campbell, M Clare Robertson, Gordon F SandersonDunedin School of Medicine, Department of Medicine, Dunedin, New ZealandBackground: Multifocal glasses (bifocals, trifocals, and progressives increase the risk of falling in elderly people, but how they do so is unclear. To explain why glasses with progressive addition lenses increase the risk of falls and whether this can be attributed to false projection, this study aimed to 1 map the prismatic displacement of a progressive lens, and 2 test whether this displacement impaired reaction time and accuracy.Methods: The reaction times of healthy ≥75-year-olds (31 participants were measured when grasping for a bar and touching a black line. Participants performed each test twice, wearing their progressives and new, matched single vision (distance glasses in random order. The line and bar targets were positioned according to the maximum and minimum prismatic displacement effect through the progressive lens, mapped using a focimeter.Results: Progressive spectacle lenses have large areas of prismatic displacement in the central visual axis and edges. Reaction time was faster for progressives compared with single vision glasses with a centrally-placed horizontal grab bar (mean difference 101 ms, P=0.011 [repeated measures analysis] and a horizontal black line placed 300 mm below center (mean difference 80 ms, P=0.007. There was no difference in accuracy between the two types of glasses.Conclusion: Older people appear to adapt to the false projection of progressives in the central visual axis. This adaptation means that swapping to new glasses or a large change in prescription may lead to a fall. Frequently updating glasses may be more beneficial.Keywords: fall prevention, false projection, stored visual spatial information

  3. Three-dimensional linear fracture mechanics analysis by a displacement-hybrid finite-element model

    International Nuclear Information System (INIS)

    Atluri, S.N.; Kathiresan, K.; Kobayashi, A.S.

    1975-01-01

    This paper deals with a finite-element procedures for the calculation of modes I, II and III stress intensity factors, which vary, along an arbitrarily curved three-dimensional crack front in a structural component. The finite-element model is based on a modified variational principle of potential energy with relaxed continuity requirements for displacements at the inter-element boundary. The variational principle is a three-field principle, with the arbitrary interior displacements for the element, interelement boundary displacements, and element boundary tractions as variables. The unknowns in the final algebraic system of equations, in the present displacement hybrid finite element model, are the nodal displacements and the three elastic stress intensity factors. Special elements, which contain proper square root and inverse square root crack front variations in displacements and stresses, respectively, are used in a fixed region near the crack front. Interelement displacement compatibility is satisfied by assuming an independent interelement boundary displacement field, and using a Lagrange multiplier technique to enforce such interelement compatibility. These Lagrangean multipliers, which are physically the boundary tractions, are assumed from an equilibrated stress field derived from three-dimensional Beltrami (or Maxwell-Morera) stress functions that are complete. However, considerable care should be exercised in the use of these stress functions such that the stresses produced by any of these stress function components are not linearly dependent

  4. Displacement pile installation effects in sand

    NARCIS (Netherlands)

    Beijer-Lundberg, A.

    2015-01-01

    Installation effects govern the post-installation behaviour of displacement piles in sand. These effects are currently not completely understood. Suitable experimental techniques to model these installation effects include field, laboratory and experimental models. In the current thesis a

  5. Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter Vilhelm

    1996-01-01

    in the lower part of the room close to the occupant. A personal exposure model for displacement ventilated rooms is proposed. The model takes the influence of gradients and the human thermal boundary layer into account. Two new quantities describing the interaction between a person and the ventilation......Personal exposure in a displacement ventilated room is examined. The stratified flow and the considerable concentration gradients necessitate an improvement of the widely used fully mixing compartmental approach. The exposure of a seated and a standing person in proportion to the stratification...... contaminant sources, this entrainment improves the indoor air quality. Measurements of exposure due to a passive contaminant source show a significant dependence on the flow field as well as on the contaminant source location. Poor system performance is found in the case of a passive contaminant released...

  6. Stability improvement for coil position locking of joule balance

    Science.gov (United States)

    Bai, Yang; Liu, Yongmeng; Lu, Yunfeng; Hu, Pengcheng; Wang, Dawei; Li, Zhengkun; Tan, Jiubin; Zhang, Zhonghua

    2017-08-01

    The relative vertical position locking precision between the exciting and suspended coils is an important uncertainty for the Planck constant traceability in joule balance. In order to improve the relative vertical position locking precision, several stability experiments are conducted. The stability characteristics of the suspended and exciting coils are measured using a six-axis laser interferometer system; meanwhile, the effectiveness of the active vibration isolation table is measured using a vibration measurement sensor. The piezoelectric ceramic actuators with PID controller are used to compensate the relative vertical displacement drifts while a six-axis laser interferometer system is used to measure the positions of two coils. Experimental results show that the relative vertical position is stably locked.

  7. Gaas Displacement Damage Dosimeter Based on Diode Dark Currents

    Directory of Open Access Journals (Sweden)

    Warner Jeffrey H.

    2017-01-01

    Full Text Available GaAs diode dark currents are correlated over a very large proton energy range as a function of displacement damage dose (DDD. The linearity of the dark current increase with DDD over a wide range of applied voltage bias deems this device an excellent candidate for a displacement damage dosimeter. Additional proton testing performed in situ enabled error estimate determination to within 10% for simulated space use.

  8. Damage energy and displacement cross sections: survey and sensitivity

    International Nuclear Information System (INIS)

    Doran, D.G.; Parkin, D.M.; Robinson, M.T.

    1976-10-01

    Calculations of damage energy and displacement cross sections using the recommendations of a 1972 IAEA Specialists' Meeting are reviewed. The sensitivity of the results to assumptions about electronic energy losses in cascade development and to different choices respecting the nuclear cross sections is indicated. For many metals, relative uncertainties and sensitivities in these areas are sufficiently small that adoption of standard displacement cross sections for neutron irradiations can be recommended

  9. Urban revitalization and displacement: types, causes, and public policy

    Energy Technology Data Exchange (ETDEWEB)

    Feagin, J.R.

    1981-05-01

    The policy research report reviews the scholarly and print media literatures on urban revitalization. The extent of revitalization; the incumbent or occupant upgrading; gentrification (displacement of low- and moderate-income households by better-off households); gentrification and displacement from all causes; and the role of powerful actors in revitalization are discussed. Public policy dealing with land use and development in urban areas is discussed. Future research needs are indicated.

  10. Neighborhood noise pollution as a determinant of displaced aggression: a pilot study.

    Science.gov (United States)

    Dzhambov, Angel; Dimitrova, Donka

    2014-01-01

    Noise pollution is still a growing public health problem with a significant impact on psychological health and well-being. The aim of this study was to investigate the impact of noise on displaced aggression (DA) in different subgroups of residents in one of the neighborhoods of Plovdiv city. A cross-sectional semi-structured interview survey was conducted using specially designed data registration forms and 33 close-ended and open-ended questions, divided into two major panels - one original and a modified version of the Displaced Aggression Questionnaire (DAQ). The mean score for DA was 61.12 (±19.97). Hearing noises above the perceived normal threshold, higher noise sensitivity and continuous noises were associated with higher levels of DA. Low frequency and high intensity noises were also associated with higher DA scores. Multiple regression model supported these findings. Contradictory to previous research age was positively correlated with noise sensitivity and aggression. We speculated that this might be due to the relatively lower socio-economic standard and quality of life in Bulgaria. Therefore, social climate might be modifying the way people perceive and react to environmental noise. Finally, the DAQ proved to be a viable measurement tool of these associations and might be further implemented and modified to suit the purposes of psychoacoustic assessment.

  11. Neutron scattering by anharmonic crystals and the effect of sublattice displacements

    International Nuclear Information System (INIS)

    Viswanathan, K.S.; Phillip, Jacob

    1979-01-01

    A theory has been described for the scattering of neutrons by anharmonic crystals, for which terms of the type Vsup(3) (k 1 j 1 ;-k 1 j 1 ;aj) which contribute to the sublattice displacements are not neglected. It is shown that the sublattice displacements will modify the phase factor arising from the scattering by any atom in the unit cell, and the Debye-Waller factor also gets altered both by the sublattice displacements as well as by higher order terms arising from anharmonicity. (author)

  12. Neogene displacements in the Solomon Islands Arc

    Science.gov (United States)

    Ridgway, J.

    1987-02-01

    The geology and present configuration of the Solomon Island arc can be explained in terms of the Neogene displacement of a single linear chain of islands. The central part of an original arc consisting of Bougainville, Choiseul, Santa Ysabel, Guadalcanal and San Cristobal was displaced to the northeast as a consequence of the attempted subduction of the Woodlark spreading system. Malaita arose on the northeastern side of the arc as a result of interaction between the arc and the Pacific Ocean floor and the volcanic islands of the New Georgia group formed to the southwest in response to the subduction of a spreading ridge, thus giving rise to the present double chain structure of the arc.

  13. Fission-neutron displacement cross sections in metals

    International Nuclear Information System (INIS)

    Takamura, Saburo; Aruga, Takeo; Nakata, Kiyotomo

    1985-01-01

    The sensitivity damage rates for 22 metals were measured after fission-spectrum neutron irradiation at low temperature and the experimental damage rates were compared with the theoretical calculation. The relation between the theoretical displacement cross section and the atomic weight of metals can be written by two curves; one is for fcc and hcp metals, and another is for bcc metals. On the other hand, the experimental displacement cross section versus atomic weight is shown approximately by a curve for both fcc and bcc metals, and the cross section for hcp metals deviates from the curve. The defect production efficiency is 0.3-0.4 for fcc metals and 0.6-0.8 for bcc metals. (orig.)

  14. Displacement of oil by carbon dioxide. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Orr, Jr., F. M.; Taber, J. J.

    1981-05-01

    Results of a comprehensive research program on factors influencing CO/sub 2/ flooding are reported. Equipment constructed for static equilibrium measurements of phase volumes, compositions, densities and viscosities is described. Design of an apparatus used for a variety of displacement tests is also reported. Apparatus and experimental procedures are described for a new experiment in which equilibrium phase compositions can be measured rapidly and continuously. Results of displacements of crude oil from slim tubes, cores and mixing cells are presented and interpreted in terms of detailed measurements of the phase behavior and fluid properties of the CO/sub 2/-crude oil mixtures. The complex phase behavior of low temperature CO/sub 2/-crude oil mixtures is described and compared with similar behavior for CO/sub 2/-alkane mixtures. A simple correlation is offered for the ranges of reservoir temperature and pressure at which liquid-liquid and liquid-liquid-vapor phase behavior should be expected to occur. Direct evidence is presented of the efficiency with which a CO/sub 2/-rich liquid phase can extract hydrocarbons from a crude oil. A simple one-dimensional process simulator for CO/sub 2/ flooding applications is described. Simulation results are compared with experimental data from slim tube displacements. Good agreement is reported between calculated and experimental results as long as the volume change of CO/sub 2/ on mixing with the oil is not too great.Sensitivity of calculated results to phase behavior and fluid properties is discussed. Comparison of displacement results, phase behavior measurements, and model calculations provides strong evidence that the high displacement efficiency which can be obtained when pressure is high enough and viscous fingering is controlled is the result of efficient extraction of a broad range of hydrocarbons by a dense CO/sub 2/-rich phase which is a liquid if the temperature is below about 50/sup 0/C (130/sup 0/F).

  15. Time between plastic displacements of elasto-plastic oscillators subject to Gaussian white noise

    DEFF Research Database (Denmark)

    Tarp-Johansen, Niels Jacob; Ditlevsen, Ove Dalager

    2001-01-01

    A one degree of freedom elasto-plastic oscillator subject to stationary Gaussian white noise has a plastic displacement response process of intermittent character. During shorter or longer time intervals the oscillator vibrates within the elastic domain without undergoing any plastic displacements...... between the clumps of plastic displacements. This is needed for a complete description of the plastic displacement process. A quite accurate fast simulation procedure is presented based on an amplitude model to determine the short waiting times in the transient regime of the elastic vibrations existing...

  16. How to avoid simulation sickness in virtual environments during user displacement

    Science.gov (United States)

    Kemeny, A.; Colombet, F.; Denoual, T.

    2015-03-01

    Driving simulation (DS) and Virtual Reality (VR) share the same technologies for visualization and 3D vision and may use the same technics for head movement tracking. They experience also similar difficulties when rendering the displacements of the observer in virtual environments, especially when these displacements are carried out using driver commands, including steering wheels, joysticks and nomad devices. High values for transport delay, the time lag between the action and the corresponding rendering cues and/or visual-vestibular conflict, due to the discrepancies perceived by the human visual and vestibular systems when driving or displacing using a control device, induces the so-called simulation sickness. While the visual transport delay can be efficiently reduced using high frequency frame rate, the visual-vestibular conflict is inherent to VR, when not using motion platforms. In order to study the impact of displacements on simulation sickness, we have tested various driving scenarios in Renault's 5-sided ultra-high resolution CAVE. First results indicate that low speed displacements with longitudinal and lateral accelerations under a given perception thresholds are well accepted by a large number of users and relatively high values are only accepted by experienced users and induce VR induced symptoms and effects (VRISE) for novice users, with a worst case scenario corresponding to rotational displacements. These results will be used for optimization technics at Arts et Métiers ParisTech for motion sickness reduction in virtual environments for industrial, research, educational or gaming applications.

  17. Displacement behaviour is associated with reduced stress levels among men but not women.

    Directory of Open Access Journals (Sweden)

    Changiz Mohiyeddini

    Full Text Available Sex differences in the ability to cope with stress may contribute to the higher prevalence of stress-related disorders among women compared to men. We recently provided evidence that displacement behaviour--activities such as scratching and face touching--represents an important strategy for coping with stressful situations: in a healthy population of men, displacement behaviour during a social stress test attenuated the relationship between anxiety experienced prior to this test, and the subsequent self-reported experience of stress. Here, we extend this work to look at physiological and cognitive (in addition to self-reported measures of stress, and study both men and women in order to investigate whether sex moderates the link between displacement behaviour and the response to stress. In a healthy study population, we quantified displacement behaviour, heart rate and cognitive performance during the Trier Social Stress Test, and used self-report questionnaires to assess the experience of stress afterwards. Men engaged in displacement behaviour about twice as often as women, and subsequently reported lower levels of stress. Bivariate correlations revealed that for men, higher rates of displacement behaviour were associated with decreased self-reported stress, fewer mistakes in the cognitive task and a trend towards lower heart rate; no relationships between displacement behaviour and stress measures were found for women. Moreover, moderation analyses revealed that high rates of displacement behaviour were associated with lower stress levels in men but not in women, and that high displacement behaviour rates were associated with poorer cognitive performance in women, but not men. These results point to an important sex difference in coping strategies, and highlight new avenues for research into sex biases in stress-related disorders.

  18. The effect of ameloblastoma and keratocystic odontogenic tumor on the displacement pattern of inferior alveolar canal in CBCT examinations

    Directory of Open Access Journals (Sweden)

    Isa Abdi

    2016-08-01

    Full Text Available Background. The inferior alveolar canal should be examined as a significant anatomical landmark, particularly in the posterior body and ramus of the mandible, for dental and surgical procedures. In the present study, the effects of two pathological lesions, ameloblastoma and keratocystic odontogenic tumor, on canal displacement were investigated. Methods. This study had a single-blinded design. Twenty-six patients with lesions in the mandible referred to Imam Reza Hospital, Tabriz, Iran, were studied in two equal groups (13 patients with a histopathological diagnosis of ameloblastoma and 13 with a histopathological diagnosis of odontogenic keratocyst. After confirming the initial incisional biopsy and pathological report, cone beam computed tomography (CBCT of lesions larger than 3 cm mesiodistaly and those involving the mandibular posterior body and ramus were included in the study. Two maxillofacial surgeons in association with an oral and maxillofacial radiologist examined three points on CBCT images to determine the mandibular canal position relative to the lesions from the lingual and buccal aspects. Results. The results of statistical analyses showed that in ameloblastoma, the inferior alveolar canal had been displaced more buccally in the ramus area (point A (84.6% but in the distal region (point C, the displacement was less buccal (41.6%. The canal was displaced buccally in 53.8% of cases at point A and in 46.2% of cases at point C in KOT lesions. Finally chi-squared test did not show any statistically significant differences between these two lesions. Conclusion. The results of this study showed no relationship between these lesions and the displacement of the mandibular canal.

  19. Atypical Case of Three Dental Implants Displaced into the Maxillary Sinus

    Directory of Open Access Journals (Sweden)

    João Felipe Bonatto Bruniera

    2015-01-01

    Full Text Available Oral rehabilitation with dental implants has become a routine treatment in contemporary dentistry. The displacement of dental implants into the sinus membrane, a complication related to the maxillary sinus, is one of the most common accidents reported in the literature. The treatment for this complication is the surgical removal of the implant. A 60-year-old woman with three dental implants displaced into the maxillary sinus (one implant displaced into the left maxillary sinus and two implants displaced into the right maxillary sinus underwent surgery for removal of the implants. The surgery to remove the implants was performed under local anesthesia through the Caldwell-Luc technique. The patient was subsequently administered antibiotic, anti-inflammatory, and analgesic drugs. The patient returned 7 days after the surgery for suture removal and is being regularly monitored to determine whether future rehabilitation of the edentulous area is necessary. In conclusion, surgical removal of the dental implant displaced into the maxillary sinus is the treatment of choice. This technique is appropriate because it allows the use of local anesthesia and provides direct visualization for the removal of the implants.

  20. Study of electroosmosis-driven two-liquid displacement flow in a microcapillary

    International Nuclear Information System (INIS)

    Gan, H Y; Yang, C; Wan, S Y M; Lim, G C; Lam, Y C

    2006-01-01

    Multi-liquid flow, such as one liquid displacing another liquid, is frequently encountered in practice. This can be achieved by electroosmotic (EO) pumping, which has its own unique characteristics and advantages. This investigation is on EO-driven, two-liquid displacement flow in a microcapillary. A theoretical model was developed to take into consideration the axial step change of velocity flow fields at the time-dependent liquid/liquid interface, continuity requirement, and induced local pressure gradients. The electrical current monitoring method was employed to measure the flowrate and subsequently determine the capillary zeta potentials which are required for the model prediction. The nonlinear change of the electrical current with time under a constant applied voltage was observed during the displacement process. The theoretical and experimental results validated the hypothesis that the non-uniform zeta potential and electric field induce local pressure gradients in the two different liquids. Our experimental results indicated that the time of displacement, and thus the flow velocity, is found to be dependent on the displacing flow direction, which has hitherto not been reported in the literature. The underlying mechanisms were postulated, but demand further investigation