WorldWideScience

Sample records for lymphoma computed tomography

  1. Multifocal sparganosis mimicking lymphoma involvement: Multimodal imaging findings of ultrasonography, CT, MRI, and position emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heo, So Young; Park, Ji Yeon; Park, Noh Hyuck; Park, Chan Sub; Kim, Tae Jung [Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Yi, Seong Yoon [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang (Korea, Republic of); Jun, Hyun Jung [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2016-01-15

    Sparganosis is a rare parasitic disease caused by the migrating plerocercoid larva of Spirometra species tapeworms. The most frequent clinical manifestation is a subcutaneous nodule resembling a neoplasm. In this study, we presented multimodal findings of ultrasonography, computed tomography, magnetic resonance imaging, positron emission tomography-computed tomography and follow-up imagings on multifocal sparganosis, mimicking lymphoma involvement in a patient with lymphoma.

  2. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Jakobsen, Annika Loft; Hansen, Mads;

    2006-01-01

    In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study was to investigate the value...

  3. Use of Computed Tomography Angiography in Hodgkin Lymphoma Survivors

    OpenAIRE

    Küpeli, Serhan

    2014-01-01

    In the treatment of Hodgkin lymphoma, anthracyclines known to be cardiotoxic and radiotherapy to the involved lymphatic areas are frequently used. In literature deaths from myocardial infarction at young ages after Hodgkin lymphoma have been reported. The real incidence of cardiovascular diseases in patients treated for Hodgkin lymphoma is not known. There is a significant correlation between mediastinal radiotherapy and development of a coronary artery abnormality. Coronary computed tomogra...

  4. Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; d´Amore, Francesco; Juul Mylam, Karen

    2012-01-01

    Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma......Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma...

  5. 18F-fluorodeoxyglucose positron emission tomography/computed tomography comparison of gastric lymphoma and gastric carcinoma

    OpenAIRE

    Li, Xiao-Feng; Fu, Qiang; Dong, You-Wen; Liu, Jian-Jing; Song,Xiu-yu; Dai, Dong; Zuo, Cong; Xu, Wen-Gui

    2016-01-01

    AIM To compare 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) features in gastric lymphoma and gastric carcinoma. METHODS Patients with newly diagnosed gastric lymphoma or gastric carcinoma who underwent 18F-FDG PET/CT prior to treatment were included in this study. We reviewed and analyzed the PET/CT features of gastric wall lesions, including FDG avidity, pattern (focal/diffuse), and intensity [maximal standard uptake value: (SUVmax)]. The correlati...

  6. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... standard limits the reliability of accuracy calculations. RESULTS: FDG-PET would have upstaged 19% of patients and downstaged 5% of patients, leading to a different treatment in 9% of patients. For FDG-PET/CT, the corresponding figures are 17%, 5%, and 7%. In nodal regions, the sensitivity of FDG...

  7. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome.

    Science.gov (United States)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome.

  8. Value of computed tomography-guided core needle biopsy in diagnosis of primary pulmonary lymphomas.

    Science.gov (United States)

    Wang, Zhiwei; Li, Xiaoguang; Chen, Jin; Jin, Zhengyu; Shi, Haifeng; Zhang, Xiaobo; Pan, Jie; Liu, Wei; Yang, Ning; Chen, Jie

    2013-01-01

    To evaluate the value of computed tomography (CT)-guided core needle biopsy in diagnosis of primary pulmonary lymphoma and its subtypes. A retrospective analysis of the records of all patients with primary pulmonary lymphoma between January 2005 and August 2011 was performed. There were 25 patients referred to the radiology department for CT-guided core needle biopsy. The success rate and complications were assessed. A definitive diagnosis and accurate histologic subtype were obtained in 21 patients with a success rate of 84.0%. Diagnosis was made in the other four patients with bronchoscopy and surgery. Non-Hodgkin lymphoma (NHL) was the diagnosis in all patients. Most subtypes were mucosa-associated lymphoid tissue (MALT) lymphomas (n = 19). The remaining subtypes included three diffuse large B-cell NHLs, two peripheral T-cell lymphomas not otherwise specified, and one anaplastic large cell NHL. The success rate of core needle biopsy was 95% (18 of 19) for MALT lymphomas, 67% (2 of 3) for diffuse large B cell NHLs, and 33% (1 of 3) for other NHLs. The success rate for MALT lymphomas was significantly higher than that of non-MALT lymphomas according to Fisher exact t test (P = .031). No serious complications occurred in any patients. CT-guided core needle biopsy is a reliable procedure to assist in diagnosis and classification of primary pulmonary lymphomas, especially MALT lymphomas. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  9. (18)F-fluorodeoxyglucose positron emission tomography/computed tomography comparison of gastric lymphoma and gastric carcinoma.

    Science.gov (United States)

    Li, Xiao-Feng; Fu, Qiang; Dong, You-Wen; Liu, Jian-Jing; Song, Xiu-Yu; Dai, Dong; Zuo, Cong; Xu, Wen-Gui

    2016-09-14

    To compare (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) features in gastric lymphoma and gastric carcinoma. Patients with newly diagnosed gastric lymphoma or gastric carcinoma who underwent (18)F-FDG PET/CT prior to treatment were included in this study. We reviewed and analyzed the PET/CT features of gastric wall lesions, including FDG avidity, pattern (focal/diffuse), and intensity [maximal standard uptake value: (SUVmax)]. The correlation of SUVmax with gastric clinicopathological variables was investigated by χ(2) test, and receiver-operating characteristic (ROC) curve analysis was performed to determine the differential diagnostic value of SUVmax-associated parameters in gastric lymphoma and gastric carcinoma. Fifty-two patients with gastric lymphoma and 73 with gastric carcinoma were included in this study. Abnormal gastric FDG accumulation was found in 49 patients (94.23%) with gastric lymphoma and 65 patients (89.04%) with gastric carcinoma. Gastric lymphoma patients predominantly presented with type I and type II lesions, whereas gastric carcinoma patients mainly had type III lesions. The SUVmax (13.39 ± 9.24 vs 8.35 ± 5.80, P gastric lymphoma compared with gastric carcinoma. ROC curve analysis suggested a better performance of SUVmax/THKmax in the evaluation of gastric lesions between gastric lymphoma and gastric carcinoma in comparison with that of SUVmax alone. PET/CT features differ between gastric lymphoma and carcinoma, which can improve PET/CT evaluation of gastric wall lesions and help differentiate gastric lymphoma from gastric carcinoma.

  10. 18F-fluorodeoxyglucose positron emission tomography/computed tomography comparison of gastric lymphoma and gastric carcinoma

    Science.gov (United States)

    Li, Xiao-Feng; Fu, Qiang; Dong, You-Wen; Liu, Jian-Jing; Song, Xiu-Yu; Dai, Dong; Zuo, Cong; Xu, Wen-Gui

    2016-01-01

    AIM To compare 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) features in gastric lymphoma and gastric carcinoma. METHODS Patients with newly diagnosed gastric lymphoma or gastric carcinoma who underwent 18F-FDG PET/CT prior to treatment were included in this study. We reviewed and analyzed the PET/CT features of gastric wall lesions, including FDG avidity, pattern (focal/diffuse), and intensity [maximal standard uptake value: (SUVmax)]. The correlation of SUVmax with gastric clinicopathological variables was investigated by χ2 test, and receiver-operating characteristic (ROC) curve analysis was performed to determine the differential diagnostic value of SUVmax-associated parameters in gastric lymphoma and gastric carcinoma. RESULTS Fifty-two patients with gastric lymphoma and 73 with gastric carcinoma were included in this study. Abnormal gastric FDG accumulation was found in 49 patients (94.23%) with gastric lymphoma and 65 patients (89.04%) with gastric carcinoma. Gastric lymphoma patients predominantly presented with type I and type II lesions, whereas gastric carcinoma patients mainly had type III lesions. The SUVmax (13.39 ± 9.24 vs 8.35 ± 5.80, P gastric lymphoma compared with gastric carcinoma. ROC curve analysis suggested a better performance of SUVmax/THKmax in the evaluation of gastric lesions between gastric lymphoma and gastric carcinoma in comparison with that of SUVmax alone. CONCLUSION PET/CT features differ between gastric lymphoma and carcinoma, which can improve PET/CT evaluation of gastric wall lesions and help differentiate gastric lymphoma from gastric carcinoma. PMID:27678362

  11. Are we ready for positron emission tomography/computed tomography-based target volume definition in lymphoma radiation therapy?

    Science.gov (United States)

    Yeoh, Kheng-Wei; Mikhaeel, N George

    2013-01-01

    Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) has become indispensable for the clinical management of lymphomas. With consistent evidence that it is more accurate than anatomic imaging in the staging and response assessment of many lymphoma subtypes, its utility continues to increase. There have therefore been efforts to incorporate PET/CT data into radiation therapy decision making and in the planning process. Further, there have also been studies investigating target volume definition for radiation therapy using PET/CT data. This article will critically review the literature and ongoing studies on the above topics, examining the value and methods of adding PET/CT data to the radiation therapy treatment algorithm. We will also discuss the various challenges and the areas where more evidence is required.

  12. Change in the diagnosis from classical Hodgkin's lymphoma to anaplastic large cell lymphoma by (18)F flourodeoxyglucose positron emission tomography/computed tomography: Importance of recognising disease pattern on imaging and immunohistochemistry.

    Science.gov (United States)

    Senthil, Raja; Mohapatra, Ranjan Kumar; Sampath, Mouleeswaran Koramadai; Sundaraiya, Sumati

    2016-01-01

    Anaplastic large cell lymphoma (ALCL) is a rare type of nonHodgkin's lymphoma (NHL), but one of the most common subtypes of T-cell lymphoma. It is an aggressive T-cell lymphoma, and some ALCL may mimic less aggressive classical HL histopathlogically. It may be misdiagnosed unless careful immunohistochemical examination is performed. As the prognosis and management of these two lymphomas vary significantly, it is important to make a correct diagnosis. We describe a case who was diagnosed as classical HL by histopathological examination of cervical lymph node, in whom (18)F-flouro deoxyglucose positron emission tomography/computed tomography appearances were unusual for HL and warranted review of histopathology that revealed anaplastic lymphoma kinase-1 negative anaplastic large T-cell lymphoma, Hodgkin-like variant, thereby changing the management.

  13. Intramuscular manifestation of non-Hodgkin lymphoma and myeloma: Prevalence, clinical signs, and computed tomography features

    Energy Technology Data Exchange (ETDEWEB)

    Surov, Alexey; Spielmann, Rolf-Peter; Behrmann, Curd (Dept. of Radiology, Martin Luther Univ., Halle-Wittenberg (Germany)), e-mail: alex.surow@medizin.uni-halle.de; Holzhausen, Hans-Juergen (Dept. of Hematology/Oncology, Martin Luther Univ., Halle-Wittenberg (Germany)); Arnold, Dirk (Dept. of Pathology, Martin Luther Univ., Halle-Wittenberg (Germany)); Schmidt, Joerg (Dept. of Medical Statistics and Controlling, Martin Luther Univ., Halle-Wittenberg (Germany))

    2010-01-15

    Background: Intramuscular manifestations of malignant immuno proliferative diseases (IMMID) are very rare. Purpose: To determine the prevalence and the clinical features of IMMID in a large series of patients, and to analyze their radiological appearances. Material and Methods: Between 1997 and 2007, 20 patients with IMMID (non-Hodgkin lymphoma [NHL], n=14, and myeloma, n=6) were identified. All patients underwent computed tomography (CT). In five cases, magnetic resonance imaging (MRI) was additionally performed. Results: Clinically, 16 patients presented with local pain and soft-tissue swelling. In four patients, IMMID was found incidentally. The most common site was the erector spinae muscle, followed by the iliopsoas and pelvic muscles. In 13 cases of IMMID, diffuse mass-forming muscle infiltration was found. Focal intramuscular masses were identified in seven cases. Conclusion: NHL mostly manifests as diffuse muscle enlargement, whereas myelomas form focal intramuscular masses. Nevertheless, CT and MR appearances are nonspecific and can be misinterpreted as muscle sarcoma or inflammatory disease. Although rare, muscle involvement should be considered in the differential diagnosis of muscle disorders in patients with non-Hodgkin lymphoma and myeloma

  14. Whole-body positron emission tomography using fluorodeoxyglucose for staging of lymphoma: effectiveness and comparison with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Stumpe, K.D.M.; Urbinelli, M.; Steinert, H.C.; Glanzmann, C.; Buck, A.; von Schulthess, G.K. [Department of Medical Radiology, University Hospital, Zurich (Switzerland)

    1998-07-01

    The purpose of this study was to evaluate whole-body positron emission tomography (WB-PET) as a staging modality in Hodgkin`s disease (HD) and non-Hodgkin lymphoma (NHL) and to compare it with computed tomography (CT) in a retrospective study. Seventy-one WB-PET studies using fluorodeoxyglucose (FDG) and 49 CT examinations were performed in 19 women and 31 men. Transaxial images were acquired and reformatted coronally and sagittally in PET. CT sections were obtained from the skull base to the pelvic floor. The written reports of the imaging data were compared with a reference standard constructed on the basis of all the data on the individual patients, including clinical follow-up of at least 6 months. The sensitivity and specificity of PET were, respectively, 86% and 96% for HD (n=53), and 89% and 100% for NHL (n=18). For CT sensitivity and specificity were 81% and 41% for HD (n=33) and 86% and 67% for NHL (n=16). Differences between PET and CT sensitivities were not significant, while in HD there was a significant difference in the specificity of PET and CT examinations, mainly because CT was unable to distinguish between active or recurrent disease and residual scar tissue after therapy. FDG tumour uptake was found in high- as well as low-grade NHL patients. In conclusion, PET appears to be highly sensitive and specific for staging of lymphoma. It is at least as sensitive as CT, and more specific, particularly in patients undergoing restaging, where a well-recognized diagnostic dilemma in CT is the presence of a post-therapeutic residual mass. (orig.) With 4 figs., 3 tabs., 23 refs.

  15. Abdomen/pelvis computed tomography in staging of pediatric Hodgkin Lymphoma: is it always necessary?

    Science.gov (United States)

    Farruggia, Piero; Puccio, Giuseppe; Sala, Alessandra; Todesco, Alessandra; Terenziani, Monica; Mura, Rosamaria; D'Amico, Salvatore; Casini, Tommaso; Mosa, Clara; Pillon, Marta; Boaro, Maria Paola; Bottigliero, Gaetano; Burnelli, Roberta; Consarino, Caterina; Fedeli, Fausto; Mascarin, Maurizio; Perruccio, Katia; Schiavello, Elisabetta; Trizzino, Angela; Ficola, Umberto; Garaventa, Alberto; Rossello, Mario

    2016-09-01

    The purpose of the study was to determine if abdomen/pelvis computed tomography (CT) can be safety omitted in the initial staging of a subgroup of children affected by Hodgkin Lymphoma (HL). Every participating center of A.I.E.O.P (Associazione Italiana di Ematologia ed Oncologia Pediatrica) sent local staging reports of 18F-fluorodeoxyglucose positron emission tomography (PET) and abdominal ultrasound (US) along with digital images of staging abdomen/pelvis CT to the investigation center where the CT scans were evaluated by an experienced pediatric radiologist. The local radiologist who performed the US was unaware of local CT and PET reports (both carried out after US), and the reviewer radiologist examining the CT images was unaware of local US, PET and CT reports. A new abdominal staging of 123 patients performed on the basis of local US report, local PET report, and centralized CT report was then compared to a simpler staging based on local US and PET. No additional lesion was discovered by CT in patients with abdomen/pelvis negativity in both US and PET or isolated spleen positivity in US (or US and PET), and so it seems that in the initial staging, abdomen/pelvis CT can be safety omitted in about 1/2 to 2/3 of children diagnosed with HL.

  16. AIDS related thoracic lymphoma: evaluation by computed tomography; Linfoma toracico na sindrome da imunodeficiencia adquirida: avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Siciliano, Antonio Alexandre de Oliveira [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Servico de Radiodiagnostico; Marchiori, Edson [Universidade Federal, Rio de Janeiro, RJ (Brazil). Curso de Pos-graduacao em Radiologia

    2000-02-01

    The authors reviewed five cases of patients with acquired immunodeficiency syndrome (AIDS) related lymphoma to describe the thoracic findings on computed tomography. The patients were followed at Hospital Universitario Clementino Fraga Filho, Hospital Universitario Antonio Pedro and Hospital da Lagoa, from November, 1989 to March 1998. Epidemiological, clinical and pathological data from these patients were quiet variable and pulmonary nodules and masses, hilar and mediastinal lymphadenopathy, and thoracic wall masses were observed. AIDS related lymphomas involving the chest are pleomorphic and most commonly extranodal. (author)

  17. Definition of bulky disease in early stage Hodgkin lymphoma in computed tomography era: prognostic significance of measurements in the coronal and transverse planes

    OpenAIRE

    Kumar, Anita; Burger, Irene A.; Zhang, Zhigang; Drill, Esther N; Migliacci, Jocelyn C.; Ng, Andrea; LaCasce, Ann; Wall, Darci; Thomas E Witzig; Ristow, Kay; Yahalom, Joachim; Moskowitz, Craig H.; Zelenetz, Andrew D.

    2016-01-01

    Disease bulk is an important prognostic factor in early stage Hodgkin lymphoma, but its definition is unclear in the computed tomography era. This retrospective analysis investigated the prognostic significance of bulky disease measured in transverse and coronal planes on computed tomography imaging. Early stage Hodgkin lymphoma patients (n=185) treated with chemotherapy with or without radiotherapy from 2000–2010 were included. The longest diameter of the largest lymph node mass was measured...

  18. Definition of bulky disease in early stage Hodgkin lymphoma in computed tomography era: prognostic significance of measurements in the coronal and transverse planes

    OpenAIRE

    Kumar, Anita; Burger, Irene A.; Zhang, Zhigang; Drill, Esther N; Migliacci, Jocelyn C.; Ng, Andrea; LaCasce, Ann; Wall, Darci; Thomas E Witzig; Ristow, Kay; Yahalom, Joachim; Moskowitz, Craig H.; Zelenetz, Andrew D.

    2016-01-01

    Disease bulk is an important prognostic factor in early stage Hodgkin lymphoma, but its definition is unclear in the computed tomography-era. This retrospective analysis investigated the prognostic significance of bulky disease measured in transverse and coronal planes on computed tomography imaging. Early stage Hodgkin lymphoma patients (n=185) treated with chemotherapy with or without radiotherapy from 2000-2010 were included. The longest diameter of the largest lymph node mass was measured...

  19. Assessment of the nature of residual masses at end of treatment in lymphoma patients using volume perfusion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Syha, R.; Gruenwald, L.; Spira, D.; Ketelsen, D.; Claussen, C.D.; Horger, M. [Eberhard Karls University, Department of Diagnostic Radiology, Tuebingen (Germany); Horger, T. [Technische Universitaet Muenchen, M2 - Lehrstuhl fuer Numerische, Garching (Germany); Vogel, W. [Eberhard Karls University, Department of Medical Oncology and Haematology, Tuebingen (Germany)

    2014-03-15

    To determine the diagnostic benefit of volume perfusion computed tomography (VPCT) at end of treatment for response assessment in lymphoma patients. Seventy-five patients with different lymphoma subtypes were included: 50/75 patients had residual masses at end of treatment, 26/50 patients underwent VPCT at baseline and at end of treatment, and 24/50 patients only had end-of-treatment VPCTs. We evaluated the size of the main lymphoma mass, its blood flow (BF), blood volume (BV) and k-trans, calculated ratios (baseline and end of treatment) as well as sensitivity/specificity/negative (NPV)/positive predictive values (PPV). For VPCT at end of treatment, a cutoff threshold between responders and non-responders was calculated. For patients undergoing VPCT at baseline and end of treatment, reduction in size, BF, BV and k-trans was significant (P < 0.001). Identification of non-response was reached at: <53 % reduction in size (sensitivity/specificity/accuracy/PPV/NPV of 88.89 %/62.5 %/80.77 %/84.21 %/71.43 %), <15 % reduction of BF (sensitivity/specificity/accuracy/PPV/NPV of 100 %/37.5 %/80.77 %/0.26 %/100 %), or <45 % reduction of k-trans (sensitivity/specificity/accuracy/PPV/NPV of 88.89 %/75 %/84.62 %/88.89 %/75 %). In the subgroup undergoing VPCT at end of treatment, BF >18.51 ml/100 ml indicated non-responsiveness (sensitivity 92.86 %, specificity 72.73 %, accuracy 84 %, PPV 81.25 %, NPV 88.89 %). VPCT seems adequate for assessment of lymphoma response at end of treatment. The degree of residual lymphoma perfusion at end of treatment helps to identify patients likely to remain in remission 1 year after completion of therapy. (orig.)

  20. Tuberculosis versus non-Hodgldn's lymphomas involving small bowel mesentery: Evaluation with contrast-enhanced computed tomography

    Institute of Scientific and Technical Information of China (English)

    Peng Dong; Bin Wang; Quan-Ye Sun; Hui Cui

    2008-01-01

    AIM: To evaluate the specific computed tomography (CT) imaging criteria for differentiating tuberculosis involving the small bowel mesenteric lymph nodes from lymphomas.METHODS: We retrospectively reviewed the anatomic distribution,CT enhancement patterns of lymphoma in 18 patients with mesenteric tuberculosis and 22 with untreated non-Hodgkin's lymphomas (NHL) involving small bowel mesentery (SBM).Of the 18 patients with tuberculosis,9 had purely mesenteric tuberculous lymphadenopathy (TL),and 9 had mesenteric TL accompanied with tuberculous mesenteritis (TLM).RESULTS: CT showed that tuberculosis and NHL mainly affected lymph nodes in the body and root of SBM.Homogeneously enhanced lymph nodes in the body and root of SBM were found more often in the NHL (P<0.05).Homogeneously mixed peripheral enhanced lymph nodes in the body of SBM were found more often in mesenteric TL and TLM (P<0.05).Peripheral enhanced lymph nodes in the root of SBM were found more often in mesenteric TL and TLM (P<0.01)."Sandwich sign" in the root of SBM was observed more often in NHL (P<0.05).COMCLUSION: Anatomic lymph node distribution,sandwich sign and specific enhancement patterns of lymphadenopathy in SBM on CT images can be used in differentiating between tuberculosis and untreated NHL involving SBM.

  1. Computed tomography of the liver in newly diagnosed Hodgkin disease and non-Hodgkin lymphoma: Staging implications

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, C.H.; Hussain, S.; Seltzer, S.E.; Chiles, C.; Castellino, R.A.

    1986-02-01

    In newly diagnosed patients with Hodgkin disease and non-Hodgkin lymphoma, the value of computed tomography (CT) of the liver was assessed as regards impact on the staging process. 201 patients at two medical centers had pretreatment abdominal CT within two weeks of liver biopsy. CT sensitivity, specificity and accuracy in both groups were determined and sensitivity in both groups was very low (8%). If liver biopsy results had been omitted, reliance on CT and other clinical staging procedures alone would have led to important staging errors in 18 of these 201 patients (9%) - overstaging would have occurred twice and understaging 16 times. In 7 additional patients, the lack of demonstration by CT of documented liver disease was without clinical consequence because disseminated extranodal lymphoma was visible at other sites or at extrahepatic regions of the same CT scan. In patients with newly diagnosed Hodgkin disease and non-Hodgkin lymphoma, CT is an unreliable indicator of liver status and cannot replace liver biopsy in supplying the data required for optimal management.

  2. Cervical lymph node hyperplasia on [(18)F]-fluorodeoxyglucose positron emission tomography/computed tomography scan after treatment of children and adolescents with malignant lymphoma.

    Science.gov (United States)

    Hu, Ying-Ying; Zhang, Xu; Long, Wen; Lin, Xiao-Ping; Zhang, Ya-Rui; Li, Yuan-Hua; Xiao, Zi-Zheng; Zheng, Rong-Liang; Liang, Pei-Yan; Fan, Wei

    2015-07-01

    To define imaging manifestations and clinical prognosis of cervical lymph node hyperplasia using [(18)F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning after treatment of children and adolescents with malignant lymphoma. Children and adolescent patients with malignant lymphoma who had high FDG uptake in their cervical lymph nodes via PET/CT after treatment, which was not due to tumor recurrence or residue, were retrospectively analyzed. Twenty-seven patients with a median age of 12 years were included; 11 had Hodgkin's disease and 16 had non-Hodgkin's lymphoma. The time from PET/CT scan to completion of therapy was 1-36 months, 85.2% (23/27) of which took place within 12 months. Three patients had confirmed lymph node follicular hyperplasia by biopsy, while all 27 patients achieved disease-free survival during the follow-up period. The maximum standardized uptake values (SUVmax) of cervical lymph nodes were 2.2-16.2 and the maximum short axis ranged from 0.3 to 1.2 cm. Cervical lymph node hyperplasia was noted in neck levels I-V, and neck level II bilaterally had the highest incidence (100%). Bilateral cervical lymph node hyperplasia was symmetrical in terms of both the SUVmax and affected locations. Thymic hyperplasia and nasopharyngeal lymphoid hyperplasia were both observed in 24 patients (88.9%). There was no relationship in terms of the SUVmax between cervical lymph nodes and thymic tissue, cervical nodes or nasopharyngeal lymphoid tissue. Cervical lymph node hyperplasia with high FDG uptake on PET/CT scans found after treating children and adolescents with malignant lymphoma can be benign processes. Awareness of this possibility may help avoid invasive procedures and over-treatment. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography evaluation of subcutaneous panniculitis-like T cell lymphoma and treatment response

    Science.gov (United States)

    Gorodetskiy, Vadim R; Mukhortova, Olga V; Aslanidis, Irakli P; Klapper, Wolfram; Probatova, Natalya A

    2016-01-01

    Subcutaneous panniculitis-like T cell lymphoma (SPTCL) is a very rare variant of non-Hodgkin’s lymphoma. Currently, there is no standard imaging method for staging of SPTCL nor for assessment of treatment response. Here, we describe our use of fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for staging and monitoring of treatment response in 3 cases of SPTCL. Primary staging by PET/CT showed that all 3 patients had multiple foci in the subcutaneous fat tissue, with SUVmax from 10.5 to 14.6. Involvement of intra-abdominal fat with high SUVmax was identified in 2 of the patients. Use of the triple drug regimen of gemcitabine, cisplatin and methylprednisolone (commonly known as “GEM-P”) as first-line therapy or second-line therapy facilitated complete metabolic response for all 3 cases. FDG PET/CT provides valuable information for staging and monitoring of treatment response and can reveal occult involvement of the intra-abdominal visceral fat. High FDG uptake on pre-treatment PET can identify patients with aggressive disease and help in selection of first-line therapy. PMID:27672640

  4. Cervical lymph node hyperplasia on [{sup 18}F]-fluorodeoxyglucose positron emission tomography/computed tomography scan after treatment of children and adolescents with malignant lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Ying-Ying, E-mail: huyy@sysucc.org.cn; Zhang, Xu, E-mail: zhangxu2@sysucc.org.cn; Long, Wen, E-mail: longwen2@sysucc.org.cn; Lin, Xiao-Ping, E-mail: linxp@sysucc.org.cn; Zhang, Ya-Rui, E-mail: zhangyr@sysucc.org.cn; Li, Yuan-Hua, E-mail: liyh@sysucc.org.cn; Xiao, Zi-Zheng, E-mail: xiaozzh@sysucc.org.cn; Zheng, Rong-Liang, E-mail: zhengrl@sysucc.org.cn; Liang, Pei-Yan, E-mail: liangpy@sysucc.org.cn; Fan, Wei, E-mail: fanwei@sysucc.org.cn

    2015-07-15

    Highlights: • Cervical lymph node hyperplasia is a benign processes. • Lymph node hyperplasia found in treated children and adolescents with lymphoma. • We define imaging manifestations of cervical lymph node hyperplasia in PET/CT. • Awareness of lymph node hyperplasia avoid invasive procedures and over-treatment. - Abstract: Purpose: To define imaging manifestations and clinical prognosis of cervical lymph node hyperplasia using [{sup 18}F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning after treatment of children and adolescents with malignant lymphoma. Methods: Children and adolescent patients with malignant lymphoma who had high FDG uptake in their cervical lymph nodes via PET/CT after treatment, which was not due to tumor recurrence or residue, were retrospectively analyzed. Results: Twenty-seven patients with a median age of 12 years were included; 11 had Hodgkin's disease and 16 had non-Hodgkin's lymphoma. The time from PET/CT scan to completion of therapy was 1–36 months, 85.2% (23/27) of which took place within 12 months. Three patients had confirmed lymph node follicular hyperplasia by biopsy, while all 27 patients achieved disease-free survival during the follow-up period. The maximum standardized uptake values (SUV{sub max}) of cervical lymph nodes were 2.2–16.2 and the maximum short axis ranged from 0.3 to 1.2 cm. Cervical lymph node hyperplasia was noted in neck levels I–V, and neck level II bilaterally had the highest incidence (100%). Bilateral cervical lymph node hyperplasia was symmetrical in terms of both the SUV{sub max} and affected locations. Thymic hyperplasia and nasopharyngeal lymphoid hyperplasia were both observed in 24 patients (88.9%). There was no relationship in terms of the SUV{sub max} between cervical lymph nodes and thymic tissue, cervical nodes or nasopharyngeal lymphoid tissue. Conclusion: Cervical lymph node hyperplasia with high FDG uptake on PET/CT scans found

  5. Renal lymphoma: spectrum of computed tomography findings; Linfoma renal: espectro de imagens na tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Maranhao, Carol Pontes de Miranda; Bauab Junior, Tufik [Faculdade de Medicina do Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Dept. de Imagem]. E-mail: tbauab@riopreto.com.br

    2005-04-01

    Isolated renal lymphoma is rare due to the absence of lymphoid tissue in kidneys. Secondary involvement occurs more frequently and is reported in up to 1/3 of the autopsies of patients who died from lymphoma. Some authors believe this is actually the only existing form of renal lymphoma. The involvement of the kidney by lymphoma would occur through hematogenic metastasis or direct tumor invasion of the peri renal space. These different types of involvement determine the several forms of renal lymphoma presentation: multiple nodules, solitary mass, renal invasion from contiguous retroperitoneal disease, peri renal disease and diffuse infiltration. In this study the imaging findings features of the different forms of involvement are presented and discussed. (author)

  6. Kikuchi-Fujimoto disease mimicking tuberculous lymphadenitis or lymphoma on fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography

    Directory of Open Access Journals (Sweden)

    Abdul Rahim N

    2016-07-01

    Full Text Available Noraini Abdul Rahim,1 Abdul Jalil Nordin,2 Chiara Rusconi,3 Cristina Gabutti,3 Erika Ravelli,4 Claudio Rossetti5 1Diagnostic Imaging Department, Serdang Hospital, Selangor, 2Centre for Diagnostic Nuclear Imaging, University Putra Malaysia, Serdang, Malaysia; 3Department of Haematology, Ospedale Niguarda, Milan, 4Unit of Haematology, Valduce Hospital, Como, 5Department of Advance Technology (Nuclear Medicine, Ospedale Niguarda, Milan, Italy Abstract: Kikuchi-Fujimoto disease, also known as histiocytic lymphadenitis is a rare and benign disease characterized by regional cervical lymphadenopathy with fever of unknown origin, affecting mainly young women. We describe a case of a young Asian female who was initially misdiagnosed as having tuberculous lymphadenitis because of multiple lymphadenopathies with 18-fluorodeoxyglucose uptake on positron emission tomography/computed tomography. Final histologic diagnosis of Kikuchi-Fujimoto disease was made after excisional biopsy of the affected lymph node. The cervical lymphadenopathy has reduced in size and lung lesions disappeared after 2 months without specific treatment. Keywords: cervical lymphadenopathy, Kikuchi disease, PET/CT features

  7. The Correlation Between Pre-treatment Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Parameters and Clinical Prognostic Factors in Pediatric Hodgkin Lymphoma

    Science.gov (United States)

    Tatcı, Ebru; Uslu Biner, İnci; Emir, Suna; Tanyıldız, Hikmet Gülşah; Özmen, Özlem; Alagöz, Engin; Gökçek, Atila; Şahin, Gürses

    2017-01-01

    Objective: To compare standardized uptake values (SUV) derived from pre-treatment 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) imaging and clinical prognostic factors in pediatric patients with Hodgkin lymphoma (HL). Methods: Pre-treatment FDG PET/CT findings of 28 children with HL were evaluated in this retrospective study. Metabolic tumor volume (MTV), SUVmax normalized by weight (SUVweight), lean body mass (SUVlbm), body surface area (SUVbsa) and plasma glucose levels of tumors (SUVglucose) were calculated using pre-treatment FDG PET/CT scan images. These metabolic parameters were correlated with clinical factors [age, sex, number of lymph node groups, presence of splenic involvement, bulky mediastinal disease, Ann Arbor stage, serum white blood cell (WBC) count, erythrocyte sedimentation rate (ESR), serum albumin and hemoglobin levels]. Results: SUVbsa, SUVlbm, SUVweight, SUVglucose and MTV were higher in patients with stage III-IV disease, bulky tumor and ≥3 lymph node groups (p0.05). SUVbsa and SUVlbm were higher in patients with anemia (p0.05). Conclusion: Metabolic parameters derived from pre-treatment FDG PET/CT may have an important role in predicting high-risk disease in patients with HL. Also, SUVbsa and SUVlbm may be better markers than SUVweight in the quantitative evaluation of FDG PET/CT scans in pediatric patients. PMID:28291005

  8. Lymphadenopathy resulting from acute toxoplasmosis mimicking relapse of non-Hodgkin′s lymphoma on fluorodeoxyglucose positron emission tomography/computed tomography

    Directory of Open Access Journals (Sweden)

    Prathamesh Joshi

    2012-01-01

    Full Text Available We report a case documenting fluorodeoxyglucose (FDG accumulation in cervical, supraclavicular and axillary lymph nodes resulting from acute toxoplasmosis. A 50-year-old Indian female with history of non-Hodgkin′s lymphoma (NHL of left breast, postchemotherapy status, was found to have hypermetabolic right cervical, supraclavicular and axillary lymph nodes on a surveillance FDG positron emission tomography/computed tomography (PET/CT scan. Her previous two PET/CT scans were unremarkable with no evidence of metabolically active disease. Therefore, a differential diagnosis of relapse of NHL versus infectious/inflammatory pathology was raised in the report. Biopsy of axillary lymph node demonstrated features characteristic of toxoplasmosis. The serological test results were also compatible with acute toxoplasmosis infection. Infective and inflammatory diseases are known to accumulate FDG, resulting in false positives for malignancy. This case demonstrates lymph nodal toxoplasmosis as a potential cause of false positive FDG PET/CT findings in patients with known malignancy and highlights the importance of histopathological and laboratory correlation for the accurate interpretation of FDG PET/CT scans.

  9. Predictive value of pretreatment positron emission tomography/computed tomography in patients with newly diagnosed extranodal natural killer/T-cell lymphoma.

    Science.gov (United States)

    Bai, Bing; Huang, Hui-Qiang; Cai, Qi-Chun; Fan, Wei; Wang, Xiao-Xiao; Zhang, Xu; Lin, Ze-Xiao; Gao, Yan; Xia, Yun-Fei; Guo, Ying; Cai, Qing-Qing; Jiang, Wen-Qi; Lin, Tong-Yu

    2013-03-01

    The role of (18)Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) in extranodal natural killer/T-cell lymphoma (ENKL) is not well established. This study aimed to investigate the prognostic role of the pretreatment maximum standardized uptake value (SUV(max)) on PET/CT in patients with newly diagnosed ENKL. Among 364 consecutive patients with newly diagnosed ENKL, 81 patients were included and reviewed. The impact of SUV(max) on survival and the relationship between SUV(max) and other clinicopathological parameters were analyzed. The median SUV(max) was 14.6 (range 2.0-45.4). The optimal cutoff value of SUV(max) to predict overall survival (OS) was 15. Patients with high SUV(max) (SUVmax >15) were associated with bulky disease (P KPI, P = 0.046), resistance to primary treatment (P = 0.014), poor OS (P 60 years (P = 0.001), stage III-IV (P = 0.023), SUV(max) >15 (P = 0.020), and bulky disease (>5 cm) (P = 0.002). By using the SUV(max), patients in most subgroups stratified by the KPI or the International Prognostic Index (IPI) were further discriminated in OS with significant statistical difference. Our results suggest the pretreatment SUV(max) is predictive of prognosis in patients with newly diagnosed ENKL. The SUV(max) may provide additional prognostic information for IPI and KPI.

  10. Gallium-67 scintigraphy in lymphoma: is there a benefit of image fusion with computed tomography?

    Energy Technology Data Exchange (ETDEWEB)

    Chajari, M' Hammed; Chesnay, Eric; Batalla, Alain; Bardet, Stephane [Service de Medecine Nucleaire, Centre Francois Baclesse, Caen (France); Lacroix, Joelle [Service de Radiologie, Centre Francois Baclesse, Caen (France); Peny, Anne-Marie; Delcambre, Corinne; Genot, Jean-Yves; Fruchard, C. [Service d' Hematologie-Cancerologie, Centre Francois Baclesse, Caen (France); Henry-Amar, Michel [Service de Recherche Clinique, Centre Francois Baclesse, Caen (France)

    2002-03-01

    We investigated whether use of CT/{sup 67}Ga SPET fusion imaging could help in the interpretation of {sup 67}Ga scintigraphy. From November 1999 to May 2001, 52 consecutive fusion studies were performed in 38 patients [22 patients with Hodgkin's disease (HD) and 16 patients with non-Hodgkin's lymphoma (NHL)] as part of pre-treatment staging (n=13), treatment evaluation (n=20) or evaluation of suspected recurrence (n=19). {sup 67}Ga scintigraphy was carried out 2 and 6 days following the injection of 185-220 MBq {sup 67}Ga citrate. On day 2, {sup 67}Ga SPET and CT were performed, focussing on the chest and/or the abdomen/pelvis. Data from each imaging method were co-registered using external markers. {sup 67}Ga scintigraphy and CT were initially interpreted independently by nuclear medicine physicians and radiologists. CT/{sup 67}Ga SPET fusion studies were then jointly interpreted and both practitioners indicated when fusion provided additional information in comparison with CT and {sup 67}Ga SPET alone. Image fusion was considered to be of benefit in 12/52 (23%) studies which were performed for initial staging (n=4), treatment evaluation (n=4) or evaluation of suspected recurrence (n=4). In these cases, image fusion allowed either confirmation and/or localisation of pathological gallium uptake (n=10) or detection of lesions not visible on CT scan (n=2). Fusion was relevant for discrimination between osseous lesions and lymph node involvement adjacent to bone, especially in the thoracic and lumbar spine and pelvis. In the abdomen and pelvis, fusion helped to differentiate physiological bowel elimination from abnormal uptake, and assisted in precisely locating uptake in neighbouring viscera of the left hypochondrium, including the spleen, left liver lobe, coeliac area, stomach wall and even the splenic flexure. At the thoracic level, fusion also proved useful for demonstrating clearly the relationships of abnormal foci to the pleura, hepatic dome

  11. Low-Dose Chest Computed Tomography for Lung Cancer Screening Among Hodgkin Lymphoma Survivors: A Cost-Effectiveness Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wattson, Daniel A., E-mail: dwattson@partners.org [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Hunink, M.G. Myriam [Departments of Radiology and Epidemiology, Erasmus Medical Center, Rotterdam, the Netherlands and Center for Health Decision Science, Harvard School of Public Health, Boston, Massachusetts (United States); DiPiro, Pamela J. [Department of Imaging, Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Das, Prajnan [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hodgson, David C. [Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Mauch, Peter M.; Ng, Andrea K. [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2014-10-01

    Purpose: Hodgkin lymphoma (HL) survivors face an increased risk of treatment-related lung cancer. Screening with low-dose computed tomography (LDCT) may allow detection of early stage, resectable cancers. We developed a Markov decision-analytic and cost-effectiveness model to estimate the merits of annual LDCT screening among HL survivors. Methods and Materials: Population databases and HL-specific literature informed key model parameters, including lung cancer rates and stage distribution, cause-specific survival estimates, and utilities. Relative risks accounted for radiation therapy (RT) technique, smoking status (>10 pack-years or current smokers vs not), age at HL diagnosis, time from HL treatment, and excess radiation from LDCTs. LDCT assumptions, including expected stage-shift, false-positive rates, and likely additional workup were derived from the National Lung Screening Trial and preliminary results from an internal phase 2 protocol that performed annual LDCTs in 53 HL survivors. We assumed a 3% discount rate and a willingness-to-pay (WTP) threshold of $50,000 per quality-adjusted life year (QALY). Results: Annual LDCT screening was cost effective for all smokers. A male smoker treated with mantle RT at age 25 achieved maximum QALYs by initiating screening 12 years post-HL, with a life expectancy benefit of 2.1 months and an incremental cost of $34,841/QALY. Among nonsmokers, annual screening produced a QALY benefit in some cases, but the incremental cost was not below the WTP threshold for any patient subsets. As age at HL diagnosis increased, earlier initiation of screening improved outcomes. Sensitivity analyses revealed that the model was most sensitive to the lung cancer incidence and mortality rates and expected stage-shift from screening. Conclusions: HL survivors are an important high-risk population that may benefit from screening, especially those treated in the past with large radiation fields including mantle or involved-field RT. Screening

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special ... the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT ...

  13. Computed tomography findings in patients less than 20 years old with lymphoma; Aspectos da tomografia computadorizada no linfoma em pacientes abaixo de 20 anos de idade

    Energy Technology Data Exchange (ETDEWEB)

    Borba, Adriana Moreira Viana [Pontificia Universidade Catolica do Rio de Janeiro (PUC-RJ), Rio de Janeiro, RJ (Brazil). Escola de Medicina; Monteiro, Alexandra Maria Vieira; Lucena, Stella Beatriz Goncalves de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Faculdade de Ciencias Medicas; Lima, Claudio Marcio Amaral de Oliveira; Ribeiro, Erica Barreiros [Hospital Naval Marcilio Dias, Rio de Janeiro, RJ (Brazil)]. E-mail: cmaol@br.inter.net; Skinner, Luis Flavio [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Faculdade de Ciencias Medicas. Hospital Universitario Pedro Ernesto (HUPE)

    2007-03-15

    Objective: To describe the general findings of lymphoma and their histological patterns in patients less than 20 years old. Materials And Methods: Twenty-two cases (16 male and 6 female, mean age 11.5 years) from the digital archive of computed tomography at the Cancer Control Center of Hospital Universitario Pedro Ernesto - Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil, were retrospectively analyzed in the period between March 2003 and July 2005. Of these 22 cases, 12 were Hodgkin's and 10 were non-Hodgkin's. Results: Overall, mediastinal lymphadenomegaly was the most frequent finding (59%), with predominance in the Hodgkin's subgroup (75%), followed by hepatosplenomegaly (50%) and cervical and retroperitoneal lymphadenomegaly (27.3%). The Hodgkin's subgroup presented a prevalence of lymphadenopathy, in many lymph node chains, followed by hepatosplenomegaly (50%). One case was found with unilateral tonsillar mass, pulmonary ground-glass opacities, and renal nodules. In the non-Hodgkin's subgroup, the disease was predominantly extranodal, characterized by hepatosplenomegaly (50%), thickening of the intestinal wall (40%), pleural effusion (30%), pulmonary nodule (20%), ascites (10%), pericardial effusion (10%) and mixed bone lesions (10%). Conclusion: Computed tomography is an extremely useful method for detection, staging and follow-up of lymphomas, with alert findings like mediastinal lymphadenopathy, hepatosplenomegaly, unilateral tonsillar mass and thickening of intestinal wall. (author)

  14. Definition of bulky disease in early stage Hodgkin lymphoma in computed tomography era: prognostic significance of measurements in the coronal and transverse planes.

    Science.gov (United States)

    Kumar, Anita; Burger, Irene A; Zhang, Zhigang; Drill, Esther N; Migliacci, Jocelyn C; Ng, Andrea; LaCasce, Ann; Wall, Darci; Witzig, Thomas E; Ristow, Kay; Yahalom, Joachim; Moskowitz, Craig H; Zelenetz, Andrew D

    2016-10-01

    Disease bulk is an important prognostic factor in early stage Hodgkin lymphoma, but its definition is unclear in the computed tomography era. This retrospective analysis investigated the prognostic significance of bulky disease measured in transverse and coronal planes on computed tomography imaging. Early stage Hodgkin lymphoma patients (n=185) treated with chemotherapy with or without radiotherapy from 2000-2010 were included. The longest diameter of the largest lymph node mass was measured in transverse and coronal axes on pre-treatment imaging. The optimal cut off for disease bulk was maximal diameter greater than 7 cm measured in either the transverse or coronal plane. Thirty patients with maximal transverse diameter of 7 cm or under were found to have bulk in coronal axis. The 4-year overall survival was 96.5% (CI: 93.3%, 100%) and 4-year relapse-free survival was 86.8% (CI: 81.9%, 92.1%) for all patients. Relapse-free survival at four years for bulky patients was 80.5% (CI: 73%, 88.9%) compared to 94.4% (CI: 89.1%, 100%) for non-bulky; Cox HR 4.21 (CI: 1.43, 12.38) (P=0.004). In bulky patients, relapse-free survival was not impacted in patients treated with chemoradiotherapy; however, it was significantly lower in patients treated with chemotherapy alone. In an independent validation cohort of 38 patients treated with chemotherapy alone, patients with bulky disease had an inferior relapse-free survival [at 4 years, 71.1% (CI: 52.1%, 97%) vs 94.1% (CI: 83.6%, 100%), Cox HR 5.27 (CI: 0.62, 45.16); P=0.09]. Presence of bulky disease on multidimensional computed tomography imaging is a significant prognostic factor in early stage Hodgkin lymphoma. Coronal reformations may be included for routine Hodgkin lymphoma staging evaluation. In future, our definition of disease bulk may be useful in identifying patients who are most appropriate for chemotherapy alone.

  15. Definition of bulky disease in early stage Hodgkin lymphoma in computed tomography era: prognostic significance of measurements in the coronal and transverse planes

    Science.gov (United States)

    Kumar, Anita; Burger, Irene A.; Zhang, Zhigang; Drill, Esther N.; Migliacci, Jocelyn C.; Ng, Andrea; LaCasce, Ann; Wall, Darci; Witzig, Thomas E.; Ristow, Kay; Yahalom, Joachim; Moskowitz, Craig H.; Zelenetz, Andrew D.

    2016-01-01

    Disease bulk is an important prognostic factor in early stage Hodgkin lymphoma, but its definition is unclear in the computed tomography era. This retrospective analysis investigated the prognostic significance of bulky disease measured in transverse and coronal planes on computed tomography imaging. Early stage Hodgkin lymphoma patients (n=185) treated with chemotherapy with or without radiotherapy from 2000–2010 were included. The longest diameter of the largest lymph node mass was measured in transverse and coronal axes on pre-treatment imaging. The optimal cut off for disease bulk was maximal diameter greater than 7 cm measured in either the transverse or coronal plane. Thirty patients with maximal transverse diameter of 7 cm or under were found to have bulk in coronal axis. The 4-year overall survival was 96.5% (CI: 93.3%, 100%) and 4-year relapse-free survival was 86.8% (CI: 81.9%, 92.1%) for all patients. Relapse-free survival at four years for bulky patients was 80.5% (CI: 73%, 88.9%) compared to 94.4% (CI: 89.1%, 100%) for non-bulky; Cox HR 4.21 (CI: 1.43, 12.38) (P=0.004). In bulky patients, relapse-free survival was not impacted in patients treated with chemoradiotherapy; however, it was significantly lower in patients treated with chemotherapy alone. In an independent validation cohort of 38 patients treated with chemotherapy alone, patients with bulky disease had an inferior relapse-free survival [at 4 years, 71.1% (CI: 52.1%, 97%) vs. 94.1% (CI: 83.6%, 100%), Cox HR 5.27 (CI: 0.62, 45.16); P=0.09]. Presence of bulky disease on multidimensional computed tomography imaging is a significant prognostic factor in early stage Hodgkin lymphoma. Coronal reformations may be included for routine Hodgkin lymphoma staging evaluation. In future, our definition of disease bulk may be useful in identifying patients who are most appropriate for chemotherapy alone. PMID:27390360

  16. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging.

    Science.gov (United States)

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E

    2016-03-01

    The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board-approved study. After a single F-FDG injection, patients consecutively underwent F-FDG PET[Fraction Slash]CT and F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on F-FDG PET/CT and F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for F-FDG PET/CT, F-FDG PET/MR, and F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between F-FDG PET/MR DWI and F-FDG PET/CT, 99.2% (κ, 0.96) between F-FDG PET/MR and F-FDG PET/CT, and 99.4% (κ, 0.97) between F-FDG PET/MR DWI and F-FDG PET/MR. There was a strong correlation between F-FDG PET/CT and F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax

  17. Pulmonary lymphomas: high-resolution computed tomography and anatomopathological correlation; Linfomas pulmonares: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@zipmail.com.br; Valiant, Paulo Marcos [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Patologia; Gutierrez, Ana Luiza Telles de Miranda; Bodanese, Larissa [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto, SP (Brazil)

    2002-02-01

    This paper describes the high-resolution computed tomography and anatomopathological findings of pulmonary lymphomas. We studied the chest high-resolution computed tomographs and histopathological data of 10 patients with biopsy-proven non-Hodgkin's or Hodgkin's disease. The most common radiologic findings in this series were areas of consolidation with air-bronchogram (n = 8). Others findings included multiple pulmonary nodules (n = 4), thickening of bronchovascular bundles (n =3) and foci of ground-glass attenuation (n =2). The present series results are consistent with the current available literature on radiographic appearance of the disease. The pathological correspondence of the areas of air space consolidation was alveolar filling by neoplastic cells, the thickening of bronchovascular bundles was secondary to lymphomatous cells infiltrates, and the areas of ground-glass attenuation corresponded to alveolar septal infiltration by these cells. (author)

  18. Impact of 18F-fluorodeoxyglucose positron emission tomography/computed tomography staging in newly diagnosed classical Hodgkin lymphoma: fewer cases with stage I disease and more with skeletal involvement.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Hutchings, Martin; Mylam, Karen Juul; Brown, Peter de Nully; Bukh, Anne; Johnsen, Hans Erik; Kamper, Peter; Loft, Annika; Iyer, Victor; Gormsen, Lars Christian; Nielsen, Anne Lerberg; Bøgsted, Martin; d'Amore, Francesco

    2014-10-01

    (18)F-Fluorodeoxyglucose positron emission tomography/ computed tomography (PET/CT) is a highly accurate staging method in classical Hodgkin lymphoma (cHL). We retrospectively compared the staging results obtained in two large cohorts of patients with cHL diagnosed before (n = 324) and after (n = 406) the introduction of PET/CT staging in a retrospective study. In PET/CT staged patients, stage I disease was less frequent (16% vs. 27%, p disease was more frequent (17% vs. 10%, p = 0.02). Imaging-detected skeletal involvement was recognized more often in PET/CT staged patients (17% vs. 2%, p Hodgkin Study Group (GHSG) risk classification (early, intermediate, advanced disease) predicted outcome in PET/CT staged patients. In conclusion, PET/CT led to higher disease stages, and the more frequently diagnosed skeletal lesions may be an adverse prognostic factor.

  19. Prognostic impact of clinician-based interpretation of 18F-fluorodeoxyglucose positron emission tomography/computed tomography reports obtained in patients with newly diagnosed diffuse large B-cell lymphoma

    DEFF Research Database (Denmark)

    Mylam, Karen J; El-Galaly, Tarec C; Hutchings, Martin;

    2014-01-01

    The aim of this study was to evaluate the prognostic value of clinician interpretation of positron emission tomography/computed tomography (PET/CT) reports at mid-therapy, interim PET (I-PET) and after the end of first-line therapy (E-PET) in patients with diffuse large B-cell lymphoma (DLBCL...... indeterminate. Indeterminate reports accounted for 59% of I-PET and 49% of E-PET reports. Two-year overall survival (OS) for patients with a positive, indeterminate and negative I-PET was 58%, 87% and 89% (p ....001) for positive, indeterminate and negative interpretation of PET/CT reports. Progression-free survival and OS did not differ significantly in patients with a negative and an indeterminate I-PET report. The use of well-defined reporting criteria, e.g. the Deauville five-point scale, is likely to reduce the number...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  3. High rate of unnecessary thymectomy and its cause. Can computed tomography distinguish thymoma, lymphoma, thymic hyperplasia, and thymic cysts?

    Energy Technology Data Exchange (ETDEWEB)

    Ackman, Jeanne B., E-mail: jackman@mgh.harvard.edu [MGH Department of Radiology, Division of Thoracic Imaging and Intervention, Founders House 202, 55 Fruit Street, Boston, MA 02114 (United States); Verzosa, Stacey, E-mail: sverzosa@mgh.harvard.edu [Massachusetts General Hospital, Harvard Medical School (United States); Kovach, Alexandra E., E-mail: akovach@mgh.harvard.edu [Massachusetts General Hospital, Harvard Medical School (United States); Louissaint, Abner, E-mail: alouissaint@mgh.harvard.edu [Massachusetts General Hospital, Harvard Medical School (United States); Lanuti, Michael, E-mail: mlanuti@mgh.harvard.edu [Massachusetts General Hospital, Harvard Medical School (United States); Wright, Cameron D., E-mail: cdwright@mgh.harvard.edu [Massachusetts General Hospital, Harvard Medical School (United States); Shepard, Jo-Anne O., E-mail: jshepard@mgh.harvard.edu [Massachusetts General Hospital, Harvard Medical School (United States); Halpern, Elkan F., E-mail: elk@mgh-ita.org [Massachusetts General Hospital, Harvard Medical School (United States)

    2015-03-15

    Highlights: •The unnecessary thymectomy rate of 44% was due to concern for thymoma, based on CT findings. •It was comprised of lymphoma, thymic cysts, thymic hyperplasia, and reactive or atrophic tissue. •There are significant differentiating features of these lesions on CT. •Knowledge of these CT features may help avert unnecessary thymectomy. •Shortcomings of CT in the evaluation of these lesions remain; in such cases, MRI or biopsy can help. -- Abstract: Purpose: To determine the non-therapeutic thymectomy rate in a recent six-year consecutive thymectomy cohort, the etiology of these unnecessary thymectomies, and the differentiating CT features of thymoma, lymphoma, thymic hyperplasia, and thymic cysts. Materials and methods: Electronic data base query of all thymectomies performed at the Massachusetts General Hospital from 2006 to 2012 yielded 160 thymectomy cases, 124 of which had available imaging. The non-therapeutic thymectomy rate (includes thymectomy for lymphoma and benign disease) was calculated. Preoperative clinical and CT imaging features were assessed by review of the in-house electronic medical record by 2 thoracic surgeons and 2 pathology-blinded radiologists, respectively. Results: The non-therapeutic thymectomy rate of 43.8% (70/160) was largely secondary to concern for thymoma and was comprised of lymphoma (54.3%, 38/70), thymic bed cysts (24.3%, 17/70), thymic hyperplasia (17.1%, 12/70), and reactive or atrophic tissue (4.3%, 3/70). Among these four lesions, there were significant differences in location with respect to midline, morphology, circumscription, homogeneity of attenuation, fatty intercalation, coexistent lymphadenopathy, overt pericardial invasion, and mass effect (p < 0.001). True thymic cysts ranged in attenuation from −20 to 58 Hounsfield units (HU), with a mean attenuation of 23 HU. Conclusion: The high rate of unnecessary thymectomy was due to misinterpretation of thymic cysts, thymic hyperplasia, and lymphoma as

  4. Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Girinsky, Theodore, E-mail: girinsky.theodore@orange.fr [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); M’Kacher, Radhia [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Lessard, Nathalie [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Koscielny, Serge [Biostatistics and Epidemiology Unit, Institut Gustave Roussy, Villejuif (France); Elfassy, Eric; Raoux, François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France); Carde, Patrice [Department of Hematology, Institut Gustave Roussy, Villejuif (France); Santos, Marcos Dos [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Margainaud, Jean-Pierre [Department of Head and Neck Surgery, Institut Gustave Roussy, Villejuif (France); Sabatier, Laure [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Ghalibafian, Mithra [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Paul, Jean-François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France)

    2014-05-01

    Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patients (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  6. Computational diagnosis of canine lymphoma

    Science.gov (United States)

    Mirkes, E. M.; Alexandrakis, I.; Slater, K.; Tuli, R.; Gorban, A. N.

    2014-03-01

    One out of four dogs will develop cancer in their lifetime and 20% of those will be lymphoma cases. PetScreen developed a lymphoma blood test using serum samples collected from several veterinary practices. The samples were fractionated and analysed by mass spectrometry. Two protein peaks, with the highest diagnostic power, were selected and further identified as acute phase proteins, C-Reactive Protein and Haptoglobin. Data mining methods were then applied to the collected data for the development of an online computer-assisted veterinary diagnostic tool. The generated software can be used as a diagnostic, monitoring and screening tool. Initially, the diagnosis of lymphoma was formulated as a classification problem and then later refined as a lymphoma risk estimation. Three methods, decision trees, kNN and probability density evaluation, were used for classification and risk estimation and several preprocessing approaches were implemented to create the diagnostic system. For the differential diagnosis the best solution gave a sensitivity and specificity of 83.5% and 77%, respectively (using three input features, CRP, Haptoglobin and standard clinical symptom). For the screening task, the decision tree method provided the best result, with sensitivity and specificity of 81.4% and >99%, respectively (using the same input features). Furthermore, the development and application of new techniques for the generation of risk maps allowed their user-friendly visualization.

  7. Aspectos da tomografia computadorizada no linfoma em pacientes abaixo de 20 anos de idade Computed tomography findings in patients less than 20 years old with lymphoma

    Directory of Open Access Journals (Sweden)

    Adriana Moreira Viana Borba

    2007-04-01

    Full Text Available OBJETIVO: Descrever os achados gerais do linfoma em pacientes abaixo de 20 anos de idade e por subtipo histológico. MATERIAIS E MÉTODOS: Estudo retrospectivo do arquivo digital de tomografia computadorizada do Centro de Controle do Câncer do Hospital Universitário Pedro Ernesto da Universidade do Estado do Rio de Janeiro, no período de março de 2003 a julho de 2005. Dos 22 casos - 16 do sexo masculino e 6 do sexo feminino, com média de idade de 11,5 anos -, 12 eram do subtipo Hodgkin e 10 eram não-Hodgkin. RESULTADOS: Dos achados gerais, verificamos as linfonodomegalias mediastinais como o mais freqüente (59%, com predomínio no grupo Hodgkin (75%, seguido por hepatoesplenomegalia (50% e linfonodomegalias cervicais e retroperitoneais (27,3%. No subtipo Hodgkin houve predomínio do acometimento linfonodal, em sucessivas cadeias, seguido pela hepatoesplenomegalia (50%. Verificamos um caso de massa tonsilar unilateral, opacidade pulmonar em "vidro-fosco" e nódulos renais. No subtipo não-Hodgkin houve predomínio extranodal caracterizado por hepatoesplenomegalia (50%, espessamento de alça intestinal (40%, derrame pleural (30%, nódulo pulmonar (20%, ascite (10%, derrame pericárdico (10% e lesões ósseas mistas (10%. CONCLUSÃO: A tomografia computadorizada é de grande valia no diagnóstico, estadiamento e seguimento do linfoma, com achados de alerta como massa linfonodal, notadamente mediastinal, hepatoesplenomegalia, massa unilateral na tonsila e espessamento parietal de alça intestinal.OBJECTIVE: To describe the general findings of lymphoma and their histological patterns in patients less than 20 years old. MATERIALS AND METHODS: Twenty-two cases (16 male and 6 female, mean age 11.5 years from the digital archive of computed tomography at the Cancer Control Center of "Hospital Universitário Pedro Ernesto - Universidade do Estado do Rio de Janeiro", Rio de Janeiro, RJ, Brazil, were retrospectively analyzed in the period between

  8. Mortui vivos docent - the dead teach the living: 18-flurodeoxyglocose positron emission tomography-computed tomography findings in a case of intravascular B cell lymphoma

    Directory of Open Access Journals (Sweden)

    Prathamesh V Joshi

    2013-01-01

    Full Text Available Intravascular large B-cell lymphoma is a rare and aggressive variant of diffuse large B-cell non-Hodgkin′s lymphoma. Its atypical presentation often delays the diagnosis and due to its aggressive behavior, the diagnosis is made post-mortem in half of the cases. We present FDG PET/CT findings in a case of IVLCL. In our case, the report of the patient′s bone marrow biopsy after death of the patient revealed the presence of IVLCL. After availability of final diagnosis, we reviewed the literature and a better explanation of the FDG PET/CT findings could be obtained. We describe this case, to call for heightened awareness in physicians for the rare but possible diagnosis of IVCLL, particularly in an elderly patient who presents with fever of unknown origin and demonstrates similar FDG PET/CT findings. Considering the characteristic scan findings described in our patient and other cases in literature, FDG PET/CT can be used in suspected cases of IVLCL for early diagnosis of this rapidly fatal malignancy.

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, more ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ... stroke and brain tumors. It also helps your doctor to evaluate your face, sinuses, and skull or ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ... the best imaging modality for sinusitis. Tell your doctor if there’s a possibility you are pregnant and ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... for a recovery period and will be given instructions on any limitations in activity for the day. ... Images related to Children's (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) CT (Computed Tomography) Sponsored ...

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography ( ... more commonly known as a CT or CAT scan, is a diagnostic medical test that, like traditional ...

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless ... table. Other imaging methods such as ultrasound or magnetic resonance (MR) imaging can provide pictures of certain areas ...

  5. Proton computed tomography

    Science.gov (United States)

    Bucciantonio, Martina; Sauli, Fabio

    2015-05-01

    Proton computed tomography (pCT) is a diagnostic method capable of in situ imaging the three-dimensional density distribution in a patient before irradiation with charged particle beams. Proposed long time ago, this technology has been developed by several groups, and may become an essential tool for advanced quality assessment in hadrontherapy. We describe the basic principles of the method, its performance and limitations as well as provide a summary of experimental systems and of results achieved.

  6. Imaging cutaneous T-Cell lymphoma with optical coherence tomography

    DEFF Research Database (Denmark)

    Ring, H.C.; Hansen Stamp, I.M.; Jemec, G.B.E.

    2012-01-01

    Aim: To investigate the presentation of a patch-stage cutaneous T-cell lymphoma (CTCL) using optical coherence tomography (OCT). Methods: A patient with a patch caused by CTCL was photographed digitally, OCT-scanned and biopsied. A normal skin area adjacent to the patch was OCT-scanned for compar......Aim: To investigate the presentation of a patch-stage cutaneous T-cell lymphoma (CTCL) using optical coherence tomography (OCT). Methods: A patient with a patch caused by CTCL was photographed digitally, OCT-scanned and biopsied. A normal skin area adjacent to the patch was OCT.......13 mm. A good immediate correlation was found between histology and OCT imaging of the sample. Conclusion: The aetiology of the elongated structures is thought to be lymphomatous infiltrates. Similar findings have been described in ocular lymphoma and may therefore be an important characteristic...

  7. Computer processing of tomography data

    OpenAIRE

    Konečný, Jan

    2011-01-01

    Computer processing of tomography data Tomographs are one of the most important diagnostic devices, which are used in every hospital nowadays; they have already been so for a considerable period of time. The different types of tomographs and the processing of tomographic data and imaging of these data are the subject of this thesis. I have described the four most common types of tomography: X-ray Computed Tomography, Magnetic Resonance Imaging, Positron Emission Tomography and Single Photon E...

  8. Multiplanner spine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. K.; Jeon, H. J.; Hong, K. C.; Chung, K. B.; Suh, W. H. [Korea University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    The computed tomography is useful in evaluation of bony structures and adjacent soft tissues of the spine. Recently, the multiplanar spine CT scan is highly superior than usual axial scan, because of easily demonstrable longitudinal dimension, level of spine and spinal canal. We evaluated 62 cases of spine CT, whom complains of spinal symptoms, from July, 1982 to January, 1983. The results were as follows: 1. The sex distribution of cases were 45 male and 17 female, ages were from 15 years to 76 years, and sites were 15 cervical spine, 7 thoracic spine, 42 lumbar spine and 21 sacral spine. 2. Sixty two cases of the CT diagnosis were reviewed and shows 19 cases of herniated intervertebral disc, 7 cases of spine fracture, 5 cases of degenerative disease, 4 cases of metastatic cancer, 2 cases of posterior longitudinal ligament ossification, 1 case of cord injury and 24 cases of normal. 3. The CT findings of herniated intervertebral disc were protruding disc, obliteration of anterior epidural fat, with or without indentation of dural sac and calcification within posterior disc margin. In cases of trauma, the multiplanar spine CT scan detects more specific extension of the fracture sites, and it is able to demonstrate relationship between fracture fragment and spinal cord, therefore operability can be decided. In case of posterior longitudinal ligament ossification, it is easy to demonstrate linear high density along posterior margin of vertebral bodies on sagittal reconstruction scan. 4. The computed tomography is diagnostic in detection of spinal disease. However, multiplanar spine CT is more diagnostic than axial computed tomography such as detecting the longitudinal dimension and demonstration of spinal canal.

  9. Abdominal perfusion computed tomography.

    Science.gov (United States)

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-02-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis.

  10. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    Clinical trials for the treatment of cystic fibrosis (CF) lung disease are important to test and optimize new therapeutic interventions. To evaluate the effect of these interventions, sensitive and accurate outcome measures are needed. The most commonly used endpoints are spirometric variables...... are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  11. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  12. Diffuse abnormalities of the trachea: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@gmail.com; Pozes, Aline Serfaty [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Escola de Medicina. Dept. de Radiologia; Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Radiologia; Irion, Klaus Loureiro [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Barillo, Jorge Luiz; Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil). Dept. de Cirurgia Clinica; Souza, Carolina Althoff [University of Ottawa, Ottawa, ON (Canada)

    2008-01-15

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  13. Metrizamide computed tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, T.; Tamakawa, Y.; Arii, H. (Akita Univ. (Japan). Faculty of Medicine); Takahashi, M.; Hirota, K.

    1981-11-01

    Serial computed tomography of the cervical cord was performed following metrizamide myelography in five cases of clinically suspected syringomyelia. The syrinx filled with refluxed metrizamide was demonstrated in all of the cases. The reflux of metrizamide into the syrinx was most marked several hours following intrathecal injection of metrizamide. Computed tomography combined with metrizamide myelography is essential in the diagnosis of communicating syringomyelia.

  14. Positron Emission Tomography/Computed Tomography Findings During Therapy Predict Outcome in Patients With Diffuse Large B-Cell Lymphoma Treated With Chemotherapy Alone but Not in Those Who Receive Consolidation Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Dabaja, Bouthaina S., E-mail: bdabaja@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hess, Kenneth [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Shihadeh, Ferial [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Podoloff, Donald A. [Department of Nuclear Medicine, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Medeiros, L. Jeffrey [Department of Hematopathology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Mawlawi, Osama [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Arzu, Isidora [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Oki, Yasuhiro; Hagemeister, Fredrick B.; Fayad, Luis E. [Department of Lymphoma/Myeloma, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Reed, Valerie K.; Kedir, Aziza; Wogan, Christine F. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rodriguez, Alma [Office of the Executive Vice President and Physician-in-Chief, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2014-06-01

    Purpose: To assess the value of mid-therapy positron emission tomography (PET) findings for predicting survival and disease progression in patients with diffuse large B-cell lymphoma, considering type of therapy (chemotherapy with or without radiation therapy). Methods and Materials: We retrospectively evaluated 294 patients with histologically confirmed diffuse large B-cell lymphoma with respect to age, sex, disease stage, International Prognostic Index score, mid-therapy PET findings (positive or negative), and disease status after therapy and at last follow-up. Overall survival (OS) and progression-free survival (PFS) were compared according to mid-therapy PET findings. Results: Of the 294 patients, 163 (55%) were male, 144 (49%) were age >61 years, 110 (37%) had stage I or II disease, 219 (74%) had International Prognostic Index score ≤2, 216 (73%) received ≥6 cycles of rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone, and 88 (30%) received consolidation radiation therapy. Five-year PFS and OS rates were associated with mid-therapy PET status: PFS was 78% for those with PET-negative (PET−) disease versus 63% for PET-positive (PET+) disease (P=.024), and OS was 82% for PET− versus 62% for PET+ (P<.002). These associations held true for patients who received chemotherapy only (PFS 71% for PET− vs 52% PET+ [P=.012], OS 78% for PET− and 51% for PET+ [P=.0055]) but not for those who received consolidation radiation therapy (PFS 84% PET− vs 81% PET+ [P=.88]; OS 90% PET− vs 81% PET+ [P=.39]). Conclusion: Mid-therapy PET can predict patient outcome, but the use of consolidation radiation therapy may negate the significance of mid-therapy findings.

  15. Pigmented villonodular synovitis mimics metastases on fluorine 18 fluorodeoxyglucose position emission tomography-computed tomography.

    Science.gov (United States)

    Elumogo, Comfort O; Kochenderfer, James N; Civelek, A Cahid; Bluemke, David A

    2016-04-01

    Pigmented villonodular synovitis (PVNS) is a benign joint disease best characterized on magnetic resonance imaging (MRI). The role of fluorine 18 fluorodeoxyglucose ((18)F-FDG) position emission tomography-computed tomography (PET-CT) in the diagnosis or characterization remains unclear. PVNS displays as a focal FDG avid lesion, which can masquerade as a metastatic lesion, on PET-CET. We present a case of PVNS found on surveillance imaging of a lymphoma patient.

  16. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... What are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  18. PET-CT在淋巴瘤中的应用:第56届美国血液学会年会报道%Application of positron emission tomography-computed tomography in lymphoma: reports from the 56th American Society of Hematology annual meeting

    Institute of Scientific and Technical Information of China (English)

    刘辉; 张春丽

    2015-01-01

    Positron emission tomography-computed tomography (PET-CT) is widely used in the diagnosis and grading of FDG-uptake lymphoma,particularly in the extranodal lesions.Baseline PET-CT improves the accuracy of subsequent response assessment.Focal FDG uptake within the bone or bone marrow is highly sensitive for involvement in Hodgkin' s lymphoma (HL) and diffuse large B-cell lymphoma (DLBCL) and is better than bone marrow biopsy.Many international trials suggest that interim scan is prognostic,but not proven as a method to guide therapy.A negative PET-CT scan at the end of therapy is the best predictor of a good outcome.However,surveillance PET-CT scan should not be done routinely.%PET-CT可用于具有FDG摄取活性的淋巴瘤分期,尤其对结外病变的诊断优于其他检查.基线的PET-CT评估利于后续的治疗效果评价.PET-CT对霍奇金淋巴瘤和弥漫大B细胞淋巴瘤的骨髓受累评价优于骨髓活组织检查.目前许多研究表明中期PET-CT与非霍奇金淋巴瘤的治疗预后相关,但尚不足以依据其结果调整治疗方案.终期PET-CT是评估FDG摄取性淋巴瘤预后的最佳指标.不推荐PET-CT用于淋巴瘤患者的随访监测.

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  3. Computed tomography of the prostate.

    Science.gov (United States)

    Van Engelshoven, J M; Kreel, L

    1979-02-01

    The conventional anatomy of the prostate is reviewed and the computed tomography (CT) anatomy described and illustrated. The results of 55 "normal" cases were analyzed for size and relationship to the symphysis pubis, retropubic space, and bladder, as shown on CT sections correlating the features with age and possible urinary symptoms. Attention is also drawn to the differences between phleboliths and prostatic calcification. Computed tomography is an effective method of demonstrating the prostate and surrounding structures and of assessing prostatic enlargement.

  4. Prognostic impact of fat tissue loss and cachexia assessed by computed tomography scan in elderly patients with diffuse large B-cell lymphoma treated with immunochemotherapy.

    Science.gov (United States)

    Camus, Vincent; Lanic, Helene; Kraut, Jerôme; Modzelewski, Romain; Clatot, Florian; Picquenot, Jean M; Contentin, Nathalie; Lenain, Pascal; Groza, Luminata; Lemasle, Emilie; Fronville, Carole; Cardinael, Nathalie; Fontoura, Marie-Laure; Chamseddine, Ali; Brehar, Oana; Stamatoullas, Aspasia; Leprêtre, Stéphane; Tilly, Hervé; Jardin, Fabrice

    2014-07-01

    Approximately 30% of DLBCL patients are older than 70 yr. This study evaluated the prognostic impact of a cachexia score (CS) including fat tissue loss (adipopenia) and sarcopenia as assessed by computed tomography (CT scan) in elderly DLBCL patients treated with chemotherapy and rituximab (R). This retrospective analysis included 80 DLBCL patients older than 70 yr treated with R-CHOP or R-miniCHOP. Skeletal muscle (SM) and visceral (V) and subcutaneous (S) adipose (A) tissues were measured by analysing CT images at the third lumbar (L3) level. The median age of the patients was 78 yr. Forty-four and 46 patients were considered sarcopenic and adipopenic, respectively. The median progression-free survival (PFS) was 13.6 months in the adipopenic group and 49.4 months in the non-adipopenic group [hazard ratio (HR) = 2.27; 95% confidence interval (CI): 1.3-4; P = 0.0042]. The median overall survival (OS) was 25.7 months in the adipopenic group and 57.1 months in the non-adipopenic group (HR = 1.93; 95% CI: 1.05-3.55; P = 0.0342). A two-point CS including adipopenia and sarcopenia was created and defined two distinct risk groups with differences in outcomes that were highly significant. The CS was predictive of the prognosis in a multivariate analysis including body mass index (BMI) (< or ≥ 25 kg/m(2) ), age (< or ≥ 80 yr), international prognostic index (IPI) and albuminaemia (HR = 3.67; 95% CI = 1.93-6.97; P < 0.0001). A CS including sarcopenia and adipopenia, assessed by a single CT scan slice, predicts outcome independent of BMI and the IPI. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Imaging Cutaneous T-Cell Lymphoma with Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Hans Christian Ring

    2012-07-01

    Full Text Available Aim: To investigate the presentation of a patch-stage cutaneous T-cell lymphoma (CTCL using optical coherence tomography (OCT. Methods: A patient with a patch caused by CTCL was photographed digitally, OCT-scanned and biopsied. A normal skin area adjacent to the patch was OCT-scanned for comparison, but not biopsied. The OCT image and the histological image were compared. Results: The OCT images illustrated a thickened and hyperreflective stratum corneum. OCT also demonstrated several elongated hyporeflective structures in the dermis. The largest structure was measured to have a width of 0.13 mm. A good immediate correlation was found between histology and OCT imaging of the sample. Conclusion: The aetiology of the elongated structures is thought to be lymphomatous infiltrates. Similar findings have been described in ocular lymphoma and may therefore be an important characteristic of cutaneous lymphoma. It may further be speculated that the differences in OCT images may reflect the biological behaviour of the infiltrate. This observation therefore suggests that OCT imaging may be a relevant tool for the in vivo investigation of mycosis fungoides and other CTCLs, but in order to verify these observed patterns in OCT imaging, further investigations will be required.

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... other in a ring, called a gantry. The computer workstation that processes the imaging information is located ...

  10. Non-Hodgkin lymphoma: computed tomographic demonstration of unusual extranodal involvement

    Energy Technology Data Exchange (ETDEWEB)

    Glazer, H.S.; Lee, J.K.T.; Balfe, D.M.; Mauro, M.A.; Griffith, R.; Sagel, S.S.

    1983-10-01

    With the advent of computed tomography, lymphomatous involvement of sites other than lymph nodes is being seen with increasing frequency. Review of computed tomographic scans in 400 patients with newly diagnosed or recurrent non-Hodgkin lymphoma revealed 37 patients to have involvement of 56 unusual sites below the diaphragm: psoas/iliacus muscle (16 patients), kidney (13 patients), pancreas (5 patients), adrenal (4 patients), skin/subcutaneous tissue (4 patients), abdominal wall musculature (4 patients), peritoneum (4 patients), omentum (3 patients), and female reproductive tract (3 patients). These were mostly seen in patients with lymphomas of diffuse architecture, especially diffuse histiocytic lymphoma. Concomitant retroperitoneal and/or mesenteric adenopathy was very common; extraodal involvement was rarely the only site of initial or recurrent lymphoma.

  11. Non-Hodgkin lymphoma: computed tomographic demonstration of unusual extranodal involvement.

    Science.gov (United States)

    Glazer, H S; Lee, J K; Balfe, D M; Mauro, M A; Griffith, R; Sagel, S S

    1983-10-01

    With the advent of computed tomography, lymphomatous involvement of sites other than lymph nodes is being seen with increasing frequency. Review of computed tomographic scans in 400 patients with newly diagnosed or recurrent non-Hodgkin lymphoma revealed 37 patients to have involvement of 56 unusual sites below the diaphragm: psoas/iliacus muscle (16 patients), kidney (13 patients), pancreas (5 patients), adrenal (4 patients), skin/subcutaneous tissue (4 patients), abdominal wall musculature (4 patients), peritoneum (4 patients), omentum (3 patients), and female reproductive tract (3 patients). These were mostly seen in patients with lymphomas of diffuse architecture, especially diffuse histiocytic lymphoma. Concomitant retroperitoneal and/or mesenteric adenopathy was very common; extranodal involvement was rarely the only site of initial or recurrent lymphoma.

  12. Computed tomography of the abnormal thymus

    Energy Technology Data Exchange (ETDEWEB)

    Baron, R.L.; Lee, J.K.T.; Sagel, S.S.; Levitt, R.G.

    1982-01-01

    Computed tomography (CT) should be the imaging method of choice following plain chest radiographs when a suspected thymic abnormality requires further evaluation. Based upon a six-year experience, including the evaluation of 25 patients with thymic pathology, CT was found useful in suggesting or excluding a diagnosis of thymoma and in distinguishing thymic hyperplasis from thymoma in patients with myasthenia gravis. The thickness of the thymic lobes determined by CT was found to be a more accurate indicator of infiltrative disease (thymic hyperplasia and lymphoma) than the width. CT was helpful in differentiating benign thymic cysts from solid tumors, and in defining the extent of a thymic neoplasms. On occasion, CT may suggest the specific histologic nature of a thymic lesion.

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  1. Computed tomography:the details.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2007-07-01

    Computed Tomography (CT) is a well established technique, particularly in medical imaging, but also applied in Synthetic Aperture Radar (SAR) imaging. Basic CT imaging via back-projection is treated in many texts, but often with insufficient detail to appreciate subtleties such as the role of non-uniform sampling densities. Herein are given some details often neglected in many texts.

  2. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  3. Cranial computed tomography in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Boltshauser, E. (Zuerich Univ. (Switzerland). Kinderklinik)

    1984-01-01

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect to probable therapeutic consequences and expected diagnostic yield. In the view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy.

  4. Predictive value of early F-18-fluoro-deoxyglucose positron emission tomography in chemosensitive relapsed lymphoma

    NARCIS (Netherlands)

    Schot, B; van Imhoff, G; Pruim, J; Sluiter, W; Vaalburg, W; Vellenga, E

    2003-01-01

    F-18-fluoro-deoxyglucose (FDG) positron emission tomography (PET) might be a better tool than computerized tomography (CT) in predicting long-term treatment outcome in patients with relapsed chemosensitive lymphoma who are candidates for autologous stem cell transplantation (ASCT). We studied patien

  5. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...... contains a survey of application examples from the manufacturing industry as well as from other industries, e.g., electrical and electronic devices, inhomogeneous materials, and from the food industry. Challenges as well as major national and international coordinated activities in the field of industrial...

  6. Computed Tomography in Forensic Medicine

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2015-01-01

    Modern diagnostic imagining techniques are gaining popularity in forensic medicine. Denmark has been involved in the development of this use of imaging techniques from the beginning. The Institute of Forensic Medicine at the University of Southern Denmark acquired a helical computed tomography (CT...... AND METHODS: This thesis investigated 900 forensic cases that were CT-scanned and autopsied at the Institute of Forensic Medicine, University of Southern Denmark, from 2006-2011. The scanner was a Siemens Somatom Spirit dual-slice CT-scanner with a Siemens Syngo MultiModality workstation. Contrast enhancement...

  7. Gallium-67 Scintigraphy in the Era of Positron Emission Tomography and Computed Tomography; Tertiary centre experience

    Directory of Open Access Journals (Sweden)

    Badriya Al-Suqri

    2015-08-01

    Full Text Available Objectives: Although 18F-fluorodeoxyglucose positron emission tomography (PET/computed tomography (CT has largely replaced the use of gallium-67 (67Ga scintigraphy in the evaluation and follow-up of lymphoma patients, 67Ga scans are still of value, particularly in countries where no PET/CT service is available. The current study presents the experience of a tertiary care centre using 67Ga scintigraphy for the evaluation of lymphomas and infections. Methods: A retrospective review was conducted of all 67Ga scans performed between 2007 and 2011 at the Royal Hospital in Muscat, Oman. Images and reports of 67Ga scans were compared to clinical and radiological follow-up data including CT and PET/CT scans and biopsies when available. Results: A total of 74 patients were referred for 67Ga scintigraphy during this period with 12 patients excluded due to lack of follow-up data, resulting in 62 patients. Among these patients, 90 67Ga scans were performed, including 59 for lymphoma, 29 for infection and two for sarcoidosis assessment. Of the infection assessment scans, 22 were performed to assess pyrexia of unknown origin and seven for follow-up after known infections. Sensitivity and specificity were found to be 80% and 88%, respectively, for the lymphoma assessment scans. For the infection assessment scans, sensitivity and specificity were reported to be 80% and 100%, respectively. Conclusion: Results from this study were consistent with other reported rates of 67Ga scan sensitivity and specificity in the evaluation of lymphomas and infections. This indicates that 67Ga scintigraphy is a useful tool for these types of evaluations when PET/CT services are not available.

  8. Future of cardiac computed tomography

    Institute of Scientific and Technical Information of China (English)

    Carlo N De Cecco; U Joseph Schoepf

    2015-01-01

    Coronary computed tomography angiography(CCTA)has become an integral tool in the noninvasive diagnostic workup of patients with suspected coronary artery disease in both elective and emergency settings. Today, it represents a mature technique providing accurate, non-invasive morphological assessment of the coronary arteries and atherosclerotic plaque burden. Iterative reconstruction algorithms, low kV imaging, and single-heart beat acquisitions hold promise to further reduce dose requirements and improve the safety and robustness of the technique in several circumstances including imaging of heavily calcified vessels, patients with morbid obesity or irregular heart rates, and assessment in the emergency setting. However, it has become clear over recent years that cardiac radiologists need to take further steps towards the development and integration of functional imaging with morphological CCTA assessment to truly provide a comprehensive evaluation of the heart. Computed tomography myocardial perfusion imaging, including both dynamic and static dual-energy approaches, has demonstrated the ability to directly assess and quantify myocardial ischemia with simultaneous CCTA acquisition with a reasonable contrast medium volume and radiation dose delivered to the patient. In order to promote CCTA in the clinical and research environments, radiologists should prepare to embrace the change from morphological to functional imaging, furnishing all the necessary resources and information to referring clinicians.

  9. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can "instantaneously"...

  10. Positron emission tomography/computerized tomography in the evaluation of primary non-Hodgkin's lymphoma of prostate.

    Science.gov (United States)

    Pan, Bo; Han, Jian-Kui; Wang, Shi-Cun; Xu, Ao

    2013-10-21

    Primary malignant lymphoma of the prostate is exceedingly rare. Here we report a case of a 65-year-old man who presented with increased urinary frequency, urinary urgency, and urinary incontinence for two years. Benign prostatic hypertrophy was suspected at primary impression. Ultrasound revealed a hypoechoic lesion of the prostate. The total serum prostate-specific antigen was within normal range. Positron emission tomography/computerized tomography (PET/CT) showed a hypermetabolic prostatic lesion. Prostate biopsy was consistent with a non-germinal center diffuse large B cell lymphoma. There was complete remission of the prostatic lesion following six cycles of chemotherapy as shown on the second PET/CT imaging. ¹⁸F-fluoro-deoxy glucose PET/CT is not only a complement to conventional imaging, but also plays a significant role in the diagnosis and evaluation of treatment response of prostatic lymphoma.

  11. Computed tomography of the gallbladder.

    Science.gov (United States)

    Havrilla, T R; Reich, N E; Haaga, J R; Seidelmann, F E; Cooperman, A M; Alfidi, R J

    1978-06-01

    Computed tomography (CT) was used to study 79 patients with suspected gallbladder disease. First and second generation scanners were used to determine the efficacy of CT in detecting cholecystitis or cholelithiasis. Manifestations of gallbladder disease such as hydrops, opaque and nonopaque gallstones, chronic cholecystitis with thickened inflammatory walls, and secondary liver abscesses can be easily detected. It is a useful technique for individuals in whom the gallbladder has failed to opacity on oral cholecystography. The scanning method is described, and estimates of reliability are given including its accuracy, limitations, and place in the management of gallbladder disease, especially cholelithiasis. When conventional radiographic examinations or ultrasound fail to give definitive diagnostic information, CT can be a useful alternative with an overall diagnostic accuracy greater than 80%.

  12. [Computer tomography of sports injuries].

    Science.gov (United States)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  13. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  14. Computed tomography of cryogenic cells

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Gerd; Anderson, E.; Vogt, S.; Knochel, C.; Weiss, D.; LeGros, M.; Larabell, C.

    2001-08-30

    Due to the short wavelengths of X-rays and low numerical aperture of the Fresnel zone plates used as X-ray objectives, the depth of field is several microns. Within the focal depth, imaging a thick specimen is to a good approximation equivalent to projecting the specimen absorption. Therefore, computed tomography based on a tilt series of X-ray microscopic images can be used to reconstruct the local linear absorption coefficient and image the three-dimensional specimen structure. To preserve the structural integrity of biological objects during image acquisition, microscopy is performed at cryogenic temperatures. Tomography based on X-ray microscopic images was applied to study the distribution of male specific lethal 1 (MSL-1), a nuclear protein involved in dosage compensation in Drosophila melanogaster, which ensures that males with single X chromosome have the same amount of most X-linked gene products as females with two X chromosomes. Tomographic reconstructions of X-ray microscopic images were used to compute the local three-dimensional linear absorption coefficient revealing the arrangement of internal structures of Drosophila melanogaster cells. Combined with labelling techniques, nanotomography is a new technique to study the 3D distribution of selected proteins inside whole cells. We want to improve this technique with respect to resolution and specimen preparation. The resolution in the reconstruction can be significantly improved by reducing the angular step size to collect more viewing angles, which requires an automated data acquisition. In addition, fast-freezing with liquid ethane instead of cryogenic He gas will be applied to improve the vitrification of the hydrated samples. We also plan to apply cryo X-ray nanotomography in order to study different types of cells and their nuclear protein distributions.

  15. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19, ... The ECG is also needed to help the computer that is connected to the CT scanner create ...

  16. RADIATION DOSE IN PAEDIATRIC COMPUTED TOMOGRAPHY ...

    African Journals Online (AJOL)

    Computed tomography (CT) is a powerful tool for the accurate ... increasing, and estimates suggest that quantitative lifetime ... Keywords: Computed Tomography, Radiation Risk, Radiation Dose, Patient Dose ... techniques, such as MRI and ultrasound, which do not ..... in the course of management are not monitored to.

  17. [Computed tomography and cranial paleoanthropology].

    Science.gov (United States)

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils.

  18. Computed tomography of the orbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jai Korl; Lee, Hwang Bok; Kang, Eun Young; Seol, Hae Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of); Ahn, Byeong Yeob [Han Mi Hospital, Seoul (Korea, Republic of)

    1987-04-15

    The development of computed tomography (CT) provided a noninvasive safe technique for imaging the orbit in any plane exquisitely demonstrating its normal anatomy as well as its pathologic process. The orbit is an ideal structure to be examined by CT because of large difference of absorption values between the intraorbital fat, muscle, optic nerve and vessels. In this study, the authors reviewed CT findings of 66 pathologically proven orbital tumors and tumorous conditions among the total of 98 cases who had taken orbital CT scan because if exophthalmos, ocular pain, diplopia and other ophthalmologic symptoms suggesting orbital masses during the period of 3 years. For the analysis of characteristic CT findings of the orbital lesions, all lesions are divided into 4 groups according to the site of origin, i.e., tumors arising in the eyeball (group 1); from intraconal space (group 2); from extraconal space (group 3); and from extraorbital regions (group 4). The results are as follows; 1.Extra tumor detection and localization was possible in 63 cases. Thus the detection rate was 95% with CT scan. 2.Among 36 males and 30 females, their age ranged from 10 months to 72 years. 3.Intraocular tumors (group 1) were 10 cases. Retinoblastoma occurred wholly in the young children under 5 years and combined with calcification in 57%. Choroidal melanoma occurred wholly in adults. 4.Intraconal tumors (group 2) were 9 cases. Vascular tumors (7 cases) were the most frequent and well enhancing mass. 5.The tumors arising in the extraconal region (group 3) were pseudotumor (12 cases), lymphoma (3 cases), dermoid cyst (4 cases), metastasis (2 cases), adenoid cystic carcinoma (1 case) and teratoma (1 case). A case of lymphoma demonstrating retrobulbar ill defined mass with scleral l thickening could not be differentiated from the pseudotumor which showing similar finding. 6.The lesions arising from extraorbital region (group 4) were PNS cancer (9 cases), mucocele (3 cases), lid cancer (4

  19. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  20. Computed tomography of arachnoid cyst

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Min Gi; Bae, Weon Tae; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun; Chung, Hyun De [College of Medicine, Chonnam National University, Kwangju (Korea, Republic of)

    1988-02-15

    The preoperative diagnosis of intracranial arachnoid cysts has been simplified, and made more rapid and accurate with computed tomography (CT). Using CT cisternography, detailed anatomic and physiologic information of arachnoid cysts could be obtained. CT features of pathologically proven 21 arachnoid cysts that were examined at Chonnam National University Hospital from June 1983 to May 1987 were analyzed. The results were as follows: 1.Prevalent age group was the 1st decade (8 cases) and male to female ratio was 17:4. 2.Clinical features were related to the location of arachnoid cyst, common symptoms were headache (53.3%), convulsion, mental change and walking disturbance. 3.Location of the arachnoid cyst were in supratentorial region (15 cases) most in middle cranial fossa (12 cases), and infratentorial region (6 cases), common at the retrocerebellar cisternal space (3 cases). 4.Shapes of arachnoid cyst were biconvex with straight inner margin (8 cases), spherical (7 cases), simple biconvex (3 cases) and others (3 cases). 5.Size of the arachnoid cyst, in the greatest dimension, was ranged from 2cm to 9cm and commonly distributed between 3cm to 5cm (14 cases). 6.Of all 14 cases, who did CT cisternography using metrizamide (11 cases) and iopamidol (3 cases), 2 cases had communication with the subarachnoid space.

  1. A Freeware Path to Neutron Computed Tomography

    Science.gov (United States)

    Schillinger, Burkhard; Craft, Aaron E.

    Neutron computed tomography has become a routine method at many neutron sources due to the availability of digital detection systems, powerful computers and advanced software. The commercial packages Octopus by Inside Matters and VGStudio by Volume Graphics have been established as a quasi-standard for high-end computed tomography. However, these packages require a stiff investment and are available to the users only on-site at the imaging facility to do their data processing. There is a demand from users to have image processing software at home to do further data processing; in addition, neutron computed tomography is now being introduced even at smaller and older reactors. Operators need to show a first working tomography setup before they can obtain a budget to build an advanced tomography system. Several packages are available on the web for free; however, these have been developed for X-rays or synchrotron radiation and are not immediately useable for neutron computed tomography. Three reconstruction packages and three 3D-viewers have been identified and used even for Gigabyte datasets. This paper is not a scientific publication in the classic sense, but is intended as a review to provide searchable help to make the described packages usable for the tomography community. It presents the necessary additional preprocessing in ImageJ, some workarounds for bugs in the software, and undocumented or badly documented parameters that need to be adapted for neutron computed tomography. The result is a slightly complicated, but surprisingly high-quality path to neutron computed tomography images in 3D, but not a replacement for the even more powerful commercial software mentioned above.

  2. Orbital computed tomography for exophthalmos

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Keun; Lee, Hyun; Sol, Chang Hyo; Kim, Byung Soo [College of Medicine, Pusan National University, Busan (Korea, Republic of)

    1987-06-15

    Since exophthalmos is caused by any decrease in the size of bony orbit or occurrence of mass within the rigid orbit, the accurate diagnosis of its causes are essential in determining the therapeutic aims. Exophthalmos is one of the important signs being the indication for orbital computed tomography along with periorbital swelling, visual loss, orbital trauma and diplopia. CT as the diagnostic tool for the cause of exophthalmos not only displays a superb role with uncomparable quality in comparison to any conventional diagnostic methods but also has a decisive role in determining the therapeutic aims and the appropriate operative method when the operation is indicated. The orbital CT was performed from May in 1983 to May in 1985 whose with chief complaints were exophthalmos and 23 cases were confirmed by operation, biopsy, clinical progression or other diagnostic procedures. Here was report thoroughly analyzed 23 cases. The results were as follows : 1. The etiologic disease of exophthalmos were 6 cases of pseudotumor, 4 cases of thyroid ophthalmopathy, 4 cases of maxill ary sinus and nasal cavity Ca., 3 cases of mucocele and 1 case of alveolar soft part sarcoma, osteoma, dermoid cyst, pleomorphic adenoma, meningioma, and C.C.F. each. 2. The origin of the etiologic diseases of exophthalmos were 13 cases of primary within bony orbit and 10 cases of secondary from adjacent structure. 3. The site of lesions were 11 cases of intraconal and extraconal, 10 cases of extraconal, and 2 cases of intraconal origin. 4. The degree of exophthalmos in CT scan was in proportion to the volume of the mass except in the case of thyroid ophthalmopathy. The upper limit of normal range by CT scan using regression line equation was 16.2 mm in approximation. 5. CT was a very useful diagnostic tool in the accurate assessment of the kinds of lesion, its location, and its relationship to adjacent structures in the diagnosis of etiologic diseases of exophthalmos.

  3. Iterative Reconstruction for Cardiopulmonary Computed Tomography

    NARCIS (Netherlands)

    Willemink, M.J.

    2015-01-01

    Introduction The number of computed tomography (CT) examinations has increased rapidly since CT became commercially available. This resulted in growing concerns regarding the risk of malignancies induced by application of medical ionizing radiation. Therefore, radiation dose reduction strategies ar

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... materials and a metallic taste in his/her mouth that lasts for a few minutes. Occasionally, a ...

  5. Quantitative computed tomography evaluation of pulmonary disease

    DEFF Research Database (Denmark)

    Mcevoy, Fintan J; Buelund, Lene; Strathe, Anders B

    2009-01-01

    Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present.......Objective assessment of pulmonary disease from computed tomography (CT) examinations is desirable but difficult. When such assessments can be made, it is important that they are related to some part of the pathophysiologic process present....

  6. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  7. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  8. Single photon emission computed tomography/computed tomography of the skull in malignant otitis externa.

    Science.gov (United States)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Kamaleshwaran, Koramadai Karuppusamy; Agrawal, Kanhaiyalal; Gupta, Ashok Kumar; Mittal, Bhagwant Rai

    2012-01-01

    Malignant otitis externa is a severe, rare infective condition of the external auditory canal and skull base. The diagnosis is generally made from a range of clinical, laboratory, and imaging findings. Technetium 99m methylene diphosphonate bone scintigraphy is known to detect osteomyelitis earlier than computed tomography. The authors present a patient with bilateral malignant otitis externa where the extent of skull base involvement was determined on 3-phase bone scintigraphy with single photon emission computed tomography/computed tomography.

  9. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  10. 18F-FLT PET/CT在弥漫大B细胞淋巴瘤诊断及分期中的价值%Value of 18F-FLT Positron Emission Tomography/Computed Tomography in Diagnosis and Staging of Diffuse Large B-cell Lymphoma

    Institute of Scientific and Technical Information of China (English)

    王瑞民; 朱海燕; 李菲; 刘长滨; 关志伟; 姚树林

    2012-01-01

    The aim of this study was to evaluate the role of 18 F-FLT positron emission tomography/computed tomography (PET/CT) in diagnosis and staging of diffuse large B-cell lymphoma ( DLBCL) patients and compare with CT. Thirty-six patients with DLBCL in our hospital from September 2008 to Desember 2009 were prospectively evaluated. All 36 patients underwent whole body and head 18F-FLT PET/CT and CT (chest, abdomen cavity and pelvis) were studied before therapy. The maximal standardized uptake value (SUVmax) of every single focus and the SUVmax of aortic arch blood pool were measured and used to calculate the median T/MB value (tumor SUVmax/ mediastinal SUVmax) of every patient. The results showed that the consistency of " F-FLT PET/CT and CT examinations in focus of DLBCL was 79. 10% , the sensitivity, specificity, positive predictive value, negative predictive value and accurate rate of 18 F-FLT PET/CT were 96. 65% , 100% , 100% , 61. 11% and 96.82% , respectively, which were much higher than that of CT (85.44% , 57.14% , 96.70% , 21.05% and 83.64%). It is concluded that the I8F-FLT PET/CT is a good means for DLBCL diagnosis and staging, which is more sensitive and specific than CT.%本研究旨在比较18F-FLT PET/CT与CT对弥漫大B细胞淋巴瘤(DLBCL)的诊断及分期的评估价值,分析DLBCL病灶的18F-FLT PET/CT显像及分布特点.收集2008年9月至2009年12月在本院经病理确诊的36例DLBCL患者,以18F-FLT PET/CT及CT扫描全身及头颅,用18F-FLT PET/CT及CT测量原发肿瘤的部位、大小及SUVmax,计算与主动脉弓血池SUVmax比值(T/MB).结果表明,18F-FLT PET/CT及CT检测DLBCL病灶的一致率为79.10%,其敏感性分别为96.65%、85.44%,特异性分别为100%、57.14%,阳性预测值分别为100%、96.70%,阴性预测值分别为61.11%、21.05%,假阳性率分别为0%、42.86%,假阴性率分别为3.35%、14.56%,准确率分别为96.82%、83.64%.以上指标组间比较均有统计学差异(P<0

  11. High-definition optical coherence tomography features of primary vitreoretinal lymphoma.

    Science.gov (United States)

    Forooghian, Farzin; Merkur, Andrew B; White, Valerie A; Shen, Defen; Chan, Chi-Chao

    2011-09-29

    Primary vitreoretinal lymphoma is a high-grade intraocular malignancy that presents as a vitritis with creamy subretinal lesions. In cases where the vitritis is dense, the characteristic subretinal lesions can be difficult to see on clinical examination. Novel high-definition imaging techniques that allow for deeper penetration through opaque media could have diagnostic utility in such cases. The authors present a case of a patient who presented with a dense vitritis that precluded visualization of fundus details. Spectral-domain optical coherence tomography using high-definition raster imaging demonstrated subretinal deposits along with outer retinal atrophy. These findings were suggestive of primary vitreoretinal lymphoma and prompted diagnostic vitrectomy. Pathological examination of the vitreous specimen confirmed the diagnosis of primary vitreoretinal lymphoma.

  12. Proton computed tomography images with algebraic reconstruction

    Science.gov (United States)

    Bruzzi, M.; Civinini, C.; Scaringella, M.; Bonanno, D.; Brianzi, M.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Presti, D. Lo; Maccioni, G.; Pallotta, S.; Randazzo, N.; Romano, F.; Sipala, V.; Talamonti, C.; Vanzi, E.

    2017-02-01

    A prototype of proton Computed Tomography (pCT) system for hadron-therapy has been manufactured and tested in a 175 MeV proton beam with a non-homogeneous phantom designed to simulate high-contrast material. BI-SART reconstruction algorithms have been implemented with GPU parallelism, taking into account of most likely paths of protons in matter. Reconstructed tomography images with density resolutions r.m.s. down to 1% and spatial resolutions CT in hadron-therapy.

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ... a gantry, which rotates around the patient. The computer that processes the imaging information and monitor are ...

  15. Computed tomography in meningeal carcinomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Koizumi, H.; Ono, N.; Horikoshi, S.; Uki, J.; Takeda, F. (Saitama Cancer Center (Japan))

    1982-04-01

    CT findings of meningeal carcinomatosis were studied in 17 patients (seven with lung cancer, two with breast cancer, one with gastric cancer, one with malignant melanoma, five with leukemia, and one with malignant lymphoma). The diagnosis was confirmed by a cytological survey of the cerebrospinal fluid and/or autopsy. Signs and symptoms caused by meningeal carcinomatosis at the CT examination varied from individual to individual. Those most frequently observed were signs of increased intracranial pressure, often accompanied by cranial nerve palsies, paresthesia, motor weakness, cerebellar signs, and nuchal stiffness, CT scan revealed evidence of meningeal carcinomatosis in ten cases out of the seventeen. CT evidences were obtained in 16.7% of the cases with hematologic malignancy and in 81.8% of those with non-hematologic malignancies. The CT findings of meningeal carcinomatosis may be summarized as follows: I. 1) Obliteration and narrowing of the cisterns and sulci, with contrast enhancement along them. 2) Enhanced spots/areas beneath the brain surface, with contrast enhancement. 3) Diffuse, slightly high density of the brain surface, with contrast enhancement. 4) Enhancement of the ventricular wall. 5) Hydrocephalus. II. 1) No CT abnormalities.

  16. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E; Haase, Robert; Laule, Michael

    2017-01-01

    OBJECTIVES: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninva...... angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low...

  17. Gastric lymphoma

    Directory of Open Access Journals (Sweden)

    Sravani Padala

    2016-06-01

    Full Text Available Gastrointestinal lymphomas represent 5-20% of extra nodal lymphomas and mainly occur in the stomach and small intestine. Clinical findings are not specific, thus often determining a delay in the diagnosis. Imaging features at conventional and cross-sectional imaging must be known by the radiologist since he/she plays a pivotal role in the diagnosis and disease assessment, thus assisting in the choice of the optimal treatment to patients. This review focuses on the wide variety of imaging presentation of esophageal, gastric, and small and large bowel lymphoma presenting their main imaging appearances at conventional and cross-sectional imaging, mainly focusing on computed tomography and magnetic resonance, helping in the choice of the best imaging technique for the disease characterization and assessment and the recognition of potential complications. Gastrointestinal tract is the most common extra nodal site involved by lymphoma. Although lymphoma can involve any part of the gastrointestinal tract .The most frequent sites in order of its occurrence are the stomach followed by small intestine and ileocecal region. Gastrointestinal tract lymphoma is usually secondary to the widespread nodal diseases and primary gastrointestinal tract lymphoma is relatively rare. [Int J Res Med Sci 2016; 4(6.000: 2481-2486

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... which are then displayed on a monitor. Special software can also generate three-dimensional (3-D) images ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ...

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or ... of the machine, the x-ray tube and electronic x-ray detectors are located opposite each other ...

  2. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M. [Service Central de Radiologie et Imagerie Medicale, CHU Grenoble (France)

    2000-02-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  3. Diagnostic role of 18F-fluorodeoxyglucose positron emission tomography for follicular lymphoma with gastrointestinal involvement

    Institute of Scientific and Technical Information of China (English)

    Masaya Iwamuro; Hiroyuki Okada; Katsuyoshi Takata; Katsuji Shinagawa; Shigeatsu Fujiki; Junji Shiode; Atsushi Imagawa

    2012-01-01

    AIM:To investigate the capacity for 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)to evaluate patients with gastrointestinal lesions of follicular lymphoma.@@METHODS:This retrospective case series consisted of 41 patients with follicular lymphoma and gastrointestinal involvement who underwent 18F-FDG-PET and endoscopic evaluations at ten different institutions between November 1996 and October 2011.Data for endoscopic,radiological,and biological examinations performed were retrospectively reviewed from clinical records.A semi-quantitative analysis of 18F-FDG uptake was performed for each involved area by calculating the maximum standardized uptake value (SUVmax).Based on the positivity of 18F-FDG uptake in the gastrointestinal lesions analyzed,patients were subdivided into two groups.To identify potential predictive factors for 18F-FDG positivity,these two groups were compared with respect to gender,age at diagnosis of lymphoma,histopathological grade,pattern of follicular dendritic cells,mitotic rate,clinical stage,soluble interleukin-2 receptor levels detected by 18F-FDG-PET,lactate dehydrogenase (LDH) levels,hemoglobin levelsbone marrow involvement,detectability of gastrointestinal lesions by computed tomography (CT) scanningand follicular lymphoma international prognostic index (FLIPI) risk.@@RESULTS:Involvement of follicular lymphoma in the stomach,duodenum,jejunum,ileum,cecum,colon,and rectum was identified in 1,34,6,3,2,3,and 6patients,respectively.No patient had esophageal involvement.In total,19/41 (46.3%) patients exhibited true-positive 18F-FDG uptake in the lesions present in their gastrointestinal tract.In contrast,false-negative 18F-FDG uptake was detected in 24 patients (58.5%),while false-positive 18F-FDG uptake was detected in 5 patients (12.2%).In the former case,2/19 patients had both 18F-FDG-positive lesions and 18F-FDG-negative lesions in the gastrointestinal tract.In patients with 18F-FDG avidity,the SUVmax value of

  4. Cervical diplomyelia revealed by computed tomography (CT)

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, G.B.; Davidovits, P.; Cerisoli, M.; Giulioni, M.

    1982-05-01

    An unusual case of cervical diplomyelia diagnosed by Computed Tomography (CT) is reported. The usefulness of CT examination in the evaluation of spinal dysraphic defects is emphasized, though performed without CSF enhancement. Visualisation of spinal cord splitting in the absence of bony spicula allows the authors to differentiate between diplomyelia and diastematomyelia which have been often described by using both terms interchangeably.

  5. Computed tomography demonstration of cholecystogastric fistula

    Directory of Open Access Journals (Sweden)

    Chung Kuao Chou, MD, MPH

    2016-06-01

    Full Text Available Cholecystogastric fistula is a rare complication of chronic cholecystitis or long-standing cholelithiasis. It results from the gradual erosion of the approximated, chronically inflamed wall of the gall bladder and stomach with fistulous tract formation. The present case describes the direct visualization of a cholecystogastric fistula by computed tomography in a patient without prior biliary system complaints.

  6. Computed tomography in untreated congenital adrenal hyperplasia

    Energy Technology Data Exchange (ETDEWEB)

    Harinarayana, C.V.; Renu, G.; Ammini, A.C.; Khurana, M.L.; Ved, P.; Karmarkar, M.G.; Ahuja, M.M.S.; Berry, M. (AIIMS, New Delhi (India))

    1991-02-01

    Six children with untreated congenital adrenal hyperplasia (CAH) were examined by computed tomography (CT). Three cases demonstrated diffuse enlargement of both adrenal glands with preservation of normal configuration and two showed tumorous transformation in one of the enlarged glands. One had equivocal in this group (age 2 years) also showed bilateral hyperplasia. (orig.).

  7. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  8. Cone beam computed tomography in veterinary dentistry

    NARCIS (Netherlands)

    van Thielen, B.; Siguenza, F.; Hassan, B.

    2012-01-01

    The purpose of this study was to assess the feasibility of cone beam computed tomography (CBCT) in imaging dogs and cats for diagnostic dental veterinary applications. CBCT scans of heads of six dogs and two cats were made. Dental panoramic and multi-planar reformatted (MPR) para-sagittal reconstruc

  9. Neutron computed tomography of rat lungs

    Energy Technology Data Exchange (ETDEWEB)

    Metzke, R W; Wall, W A [Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany); Runck, H; Stahl, C A; Schneider, M; Guttmann, J [Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany); Schillinger, B; Calzada, E; Muehlbauer, M; Schulz, M [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany); Priebe, H-J, E-mail: metzke@lnm.mw.tum.d [Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)

    2011-01-07

    Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 {mu}m, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

  10. Parallel Computing for the Computed-Tomography Imaging Spectrometer

    Science.gov (United States)

    Lee, Seungwon

    2008-01-01

    This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

  11. Computed tomography of tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Noriko; Sato, Hiromi; Kawaguchi, Tetsuro; Fujita, Katsuzo; Tanaka, Makoto (Kobe Univ. (Japan). School of Medicine)

    1982-12-01

    Recently, tuberculous meningitis has become rather rare except in areas where tuberculosis is still endemic. Six adolescents and young adults with tuberculous meningitis were evaluated by means of serial computerized tomography (CT), and the results were correlated with the findings of surgical specimens or autopsies. All cases showed meningeal irritation and fever at onset. CSF cultures revealed the presence of tuberculous bacilli. Four cases advanced rapidly to the clinical stage III and expired in a short period-between two weeks to one month from onset. On initial CT scanning, the disappearance of the basal cistern was a characteristic finding in all these cases. With the progression, an enhancement of the basal cistern on contrast injection, a localized hypodensity in adjacent parenchyma, and symmetrical ventricular dilatation appeared. Two autopsied cases showed tuberculous granulomas with purulent materials, thickened meninges, and caseous necrosis in the parenchyma around the basal cistern. The other two cases progressed rather slowly. CT findings at Stage II showed multiple enhanced spots in the basal subcortical area following contrast injection. Tuberculous granulomas were identified in these parts by means of explorative craniotomy. The authors point out the pathognomonic CT findings of tuberculous meningitis and emphasize the necessity of serial CT for the early detection and management of tuberculous meningitis.

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... detectors rotate around the patient. At the same time, the examination table is moving through the scanner, so that the x-ray beam follows a spiral path. A special computer program processes this series of pictures, or slices of the body, to ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  14. Single photon emission computed tomography/computed tomography for malignant otitis externa: lesion not shown on planar image.

    Science.gov (United States)

    Chen, Yu-Hung; Hsieh, Hung-Jen

    2013-01-01

    Malignant otitis externa is a severe and rare infection of the external acoustic meatus. Triphasic bone and (67)Ga scintigraphies are used to initial detect and follow-up the response of therapy. With single photon emission computed tomography/computed tomography images, the diagnostic sensitivity is higher. We presented a case with malignant otitis externa with initial negative planar scintigraphic finding. The lesion was detected by photon emission computed tomography/computed tomography images. We concluded that the photon emission computed tomography/computed tomography should be performed routinely for patients with suspected malignant otitis externa, even without evidence of lesion on planar images.

  15. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  16. Computed tomography of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Haughton, V.M.; Williams, A.L.

    1982-01-01

    The book describes the computed tomographic (CT) techniques for imaging the different elements comprising the spinal column and canal. The use of intravenous and intrathecal contrast enhancement and of xenon enhancement is briefly mentioned. Reconstruction techniques and special problems regarding CT of the spine are presented. CT of the spinal cord, meninges and subarachnoid space, epidural space, intervertebral discs, facet joints, and vertebrae present normal anatomy, and several common pathologic conditions. (KRM)

  17. Computed tomography in mitochondrial cytopathy

    Energy Technology Data Exchange (ETDEWEB)

    Egger, J.; Kendall, B.E.

    1981-10-01

    The clinical and computed tomographic (CT) findings in 11 proven cases of mitochondrial cytopathy (mitochondrial myopathy, Kearns Sayre syndrome, ophthalmoplegia plus) were studied. The CT changes included focal low density lesions in the basal ganglia and white matter and atrophy which could be slight or diffuse and severe. Calcification has been described in the basal ganglia, but did not occur in our series. Serial CT showed progression of the abnormalities. The differential diagnosis is discussed.

  18. Computed tomography of thymic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Candardjis, G.

    1987-05-01

    Computed tomographic examinations of 38 patients with surgically and histologically proven diagnosis were reviewed. Twenty subjects (52%) had an invasive thymoma and 16% an hyperplastic thymus. Myasthenia gravis was present in 6 cases (16%) of thymic abnormalities, four (10,5%) with invasive thymoma and two (5%) with thymic hyperplasia. Graves' disease was also present in one case of thymic hyperplasia. We emphasize the contribution of CT to the diagnosis and the prognosis.

  19. Cerebral candidiasis. Computed tomography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Chaabane, M.; Ladeb, M.F.; Bouhaouala, M.H.; Ben Hammouda, M.; Ataalah, R.; Gannouni, A.; Krifa, H.

    1989-07-01

    A three year old child who had been suffering from oral candidiasis since the age of 1 year presented with osteitis of the clavicle, 2 cerebral frontal abscesses and an occipital abscess which extended across the calvaria and was associated with osteolysis. Histological and microbiological studies following surgery confirmed the diagnosis of candidiasis in this girl who was found to have IgA immunodefinciency. The authors report the computed tomographic appearance of the cerebral lesions and review the literature. (orig.).

  20. Trip report: Marshall Space Center computed tomography

    Science.gov (United States)

    Harbour, J. R.; Andrews, M. K.

    BIR Inc. is a small company out of the Chicago area which sells equipment for producing images by tomography. They have built a relatively large instrument, called ACTIS, for NASA at the Marshall Space Center in Huntsville, Alabama and still gave access to this instrument. BIR has a grant from the Department of Energy (DOE) to determine the utility of computed tomography (CT) for characterization of nuclear and hazardous waste within the DOE complex. As part of this effort, the potential of this technique for obtaining images of canistered waste forms has been investigated. Funding for data acquisition was provided through this grant.

  1. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  2. 2-[18F]fluoro-2-deoxyglucose positron-emission tomography in staging, response evaluation, and treatment planning of lymphomas

    DEFF Research Database (Denmark)

    Specht, Lena

    2007-01-01

    2-[18F]fluoro-2-deoxyglucose positron-emission tomography (FDG-PET) is used increasingly in the clinical management of lymphomas. With regard to staging, FDG-PET is more sensitive and specific than conventional staging methods in FDG avid lymphomas (ie, Hodgkin lymphoma and most aggressive non-Ho...

  3. Computed tomography of bones and joints.

    Science.gov (United States)

    Bruna, J; Sehr, A

    1989-01-01

    The monograph sums up the problem of CT diagnosis of bones and joints making use of predominantly the authors' own experience based on CT tests of more than 45,000 patients examined at the Department of Radiology, Charles University Medical Faculty of Hygiene teaching hospital in Prague in the years 1980-1988. Specific scans of the skeleton were made in 4,500 patients, mostly for suspicion or closer assessment of neoplasms (43.5%), the radicular lumbosacral syndrome (34.5%), and injuries (12%). The opening chapters sum up basic facts about the principle of computed tomography, the apparatus in use, the evaluation of CT images, CT radiation doses, and the patients' preparation for CT scanning. The use of contrast media is discussed with regard to the possible hazards involved and to the need to hear allergological opinion first. For spinal canal visualization non-ionogenic contrast media are used exclusively. The management of side reactions to contrast medium application is also reviewed. Indications for bone and joint computed tomography now comprise a whole series of traumatological, orthopaedic, oncological, rheumatological, neurological and rehabilitation conditions, each of which is discussed in detail in a separate chapter. CT anatomical studies offer the advantage of being applicable even in patients examined for other than bone or articular diseases. The option of simultaneous soft tissue assessment represents another advantage. The authors describe different anatomical structures in terms of CT images, some of them complete with dimensional and density values. The chapter on anomalies and developmental variants stresses the relevance of computed tomography for precise characteristics of clefts of the spinal column and facial bones and for the diagnosis of anomalies and dysplasias of the spinal column and the chest. A rare case of cephalothoracopagus is demonstrated. As for traumatology, computed tomography is found useful in diagnosing fractures of the

  4. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans Henrik;

    2015-01-01

    -CCTR, showed that coronary CT angiographies accounted for only 23% of all nonregistered cardiac CTs, indicating >90% completeness of coronary CT angiographies in the WDHR-CCTR. The completeness of individual variables varied substantially (range: 0%-100%), but was >85% for more than 70% of all variables. Using......BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... expected numbers; and 4) positive predictive values as well as negative predictive values of 19 main patient and procedure variables. RESULTS: By December 31, 2012, almost 22,000 cardiac CTs with up to 40 variables for each procedure have been registered. Of these, 87% were coronary CT angiography...

  5. [Pneumothorax revealed by postoperative computed tomography].

    Science.gov (United States)

    Ikeda, Shizuka; Katori, Kiyoshi; Fujimoto, Minoru; Nitahara, Keiichi; Higa, Kazuo

    2005-11-01

    We report a case of pneumothorax revealed by postoperative computed tomography. A 39-year-old obese woman (height 153 cm, weight 70 kg) with fractures of the radius, ulna, clavicle, and femur in a traffic accident, was scheduled for osteosynthesis. Anesthesia was induced with thiopental and maintained with 50% nitrous oxide in oxygen and sevoflurane. The Spo2 decreased from 99% to 94% during the surgery. Bilateral chest sounds were symmetrical. The Spo2 increased to 100% after discontinuation of nitrous oxide. Pneumothorax was not evident on a postoperative chest X-ray, but computed tomography of the chest demonstrated right-sided pneumothorax. An ECG electrode had overlapped the fractured rib on the preoperative chest X-ray.

  6. Cone beam computed tomography in endodontic

    Energy Technology Data Exchange (ETDEWEB)

    Durack, Conor; Patel, Shanon, E-mail: conordurack1@hotmail.com [Unit of Endodontology, Department of Conservative Dentistry, King' s College London, London (United Kingdom)

    2012-07-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillofacial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontic. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice. (author)

  7. Contrast-induced nephropathy after computed tomography

    Directory of Open Access Journals (Sweden)

    Luciano da Silva Selistre

    2015-03-01

    Full Text Available Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively. Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

  8. Cone beam computed tomography in endodontics.

    Science.gov (United States)

    Durack, Conor; Patel, Shanon

    2012-01-01

    Cone beam computed tomography (CBCT) is a contemporary, radiological imaging system designed specifically for use on the maxillo-facial skeleton. The system overcomes many of the limitations of conventional radiography by producing undistorted, three-dimensional images of the area under examination. These properties make this form of imaging particularly suitable for use in endodontics. The clinician can obtain an enhanced appreciation of the anatomy being assessed, leading to an improvement in the detection of endodontic disease and resulting in more effective treatment planning. In addition, CBCT operates with a significantly lower effective radiation dose when compared with conventional computed tomography (CT). The purpose of this paper is to review the current literature relating to the limitations and potential applications of CBCT in endodontic practice.

  9. Computed tomography of ancient Egyptian mummies.

    Science.gov (United States)

    Harwood-Nash, D C

    1979-12-01

    This first report of the application of computed tomography (CT) to the study of ancient mummies, the desiccated brain of a boy and the body of a young woman within her cartonnage, shows that CT is uniquely suitable for the study of such antiquities, a study that does not necessitate destruction of the mummy or its cartonnage. Exquisite images result that are of great paleoanatomical, paleopathological, and archeological significance.

  10. Computed tomography and obstructive biliary disease.

    Science.gov (United States)

    Havrilla, T R; Haaga, J R; Alfidi, R J; Reich, N E

    1977-05-01

    Forty-four patients with confirmed biliary diseases were studied to determine the value of computed tomography (CT) in the diagnosis of biliary pathology. The results indicate that CT is useful and highly accurate in differentiating between obstructive (surgical) and nonobstructive (medical) disease entities. Of the cases with proved obstruction, 88% were correctly identified. All of the nonobstructive cases had positive CT correlation. In addition, the underlying cause of the occlusion was determined in the majority of cases.

  11. Cone Beam Computed Tomography - Know its Secrets

    OpenAIRE

    Kumar, Mohan; Shanavas, Muhammad; Sidappa, Ashwin; Kiran, Madhu

    2015-01-01

    Cone-beam computed tomography (CBCT) is an advanced imaging modality that has high clinical applications in the field of dentistry. CBCT proved to be a successful investigative modality that has been used for dental and maxillofacial imaging. Radiation exposure dose from CBCT is 10 times less than from conventional CT scans during maxillofacial exposure. Furthermore, CBCT is highly accurate and can provide a three-dimensional volumetric data in axial, sagittal and coronal planes. This article...

  12. Computed Tomography of Transverse Phase Space

    Energy Technology Data Exchange (ETDEWEB)

    Watts, A. [Fermilab; Johnstone, C. [Fermilab; Johnstone, J. [Fermilab

    2016-09-19

    Two computed tomography techniques are explored to reconstruct beam transverse phase space using both simulated beam and multi-wire profile data in the Fermilab Muon Test Area ("MTA") beamline. Both Filtered Back-Projection ("FBP") and Simultaneous Algebraic Reconstruction Technique ("SART") algorithms [2] are considered and compared. Errors and artifacts are compared as a function of each algorithm’s free parameters, and it is shown through simulation and MTA beamline profiles that SART is advantageous for reconstructions with limited profile data.

  13. Cone beam computed tomography use in orthodontics.

    Science.gov (United States)

    Nervina, J M

    2012-03-01

    Cone beam computed tomography (CBCT) is widely used by orthodontists to obtain three-dimensional (3-D) images of their patients. This is of value as malocclusion results from discrepancies in three planes of space. This review tracks the use of CBCT in orthodontics, from its validation as an accurate and reliable tool, to its use in diagnosing and treatment planning, and in assessing treatment outcomes in orthodontics.

  14. Encapsulating peritonitis: computed tomography and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kadow, Juliana Santos; Fingerhut, Carla Jeronimo Peres; Fernandes, Vinicius de Barros; Coradazzi, Klaus Rizk Stuhr; Silva, Lucas Marciel Soares; Penachim, Thiago Jose, E-mail: vinicius.barros.fernandes@gmail.com [Pontificia Universidade Catolica de Campinas (PUC-Campinas), Campinas, SP (Brazil). Hospital e Maternidade Celso Pierro

    2014-07-15

    Sclerosing encapsulating peritonitis is a rare and frequently severe entity characterized by total or partial involvement of small bowel loops by a membrane of fibrous tissue. The disease presents with nonspecific clinical features of intestinal obstruction, requiring precise imaging diagnosis to guide the treatment. The present report emphasizes the importance of computed tomography in the diagnosis of this condition and its confirmation by surgical correlation. (author)

  15. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice.

  16. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  17. Positron Computed Tomography: Current State, Clinical Results and Future Trends

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1980-09-01

    An overview is presented of positron computed tomography: its advantages over single photon emission tomography, its use in metabolic studies of the heart and chemical investigation of the brain, and future trends. (ACR)

  18. Computed tomography appearances of sclerosing encapsulating peritonitis

    Energy Technology Data Exchange (ETDEWEB)

    George, C. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)]. E-mail: cheriangeorge@hotmail.com; Al-Zwae, K. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Nair, S. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom); Cast, J.E.I. [Department of Radiology, Hull Royal Infirmary, Hull (United Kingdom)

    2007-08-15

    Sclerosing encapsulating peritonitis (SEP) is a serious complication of peritoneal dialysis (PD) characterized by thickened peritoneal membranes, which lead to decreased ultra-filtration and intestinal obstruction. Its early clinical features are nonspecific, and it is often diagnosed late following laparotomy and peritoneal biopsy, when the patient develops small bowel obstruction, which can be a life-threatening complication. However, this is changing with increasing awareness of computed tomography (CT) findings in SEP. CT can yield an early, non-invasive diagnosis that may improve patient outcome. We present a review of the CT appearances of SEP.

  19. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...... and limitations of sparse reconstruction methods in CT, in particular in a quantitative sense. For example, relations between image properties such as contrast, structure and sparsity, tolerable noise levels, suficient sampling levels, the choice of sparse reconstruction formulation and the achievable image...

  20. Computed tomography in neuronal ceroid lipofuscinosis

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neuronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter.

  1. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...... measurement uncertainties in the range 1.5–5.5 μm, showing a good stability over the 6 months of the circulation. The comparison has shown that CT measurements on the industrial parts used lie in the range 6–53 μm, with maximum values up to 158 μm....

  2. Tomography and spectroscopy as quantum computations

    CERN Document Server

    Miquel, C; Saraceno, M; Knill, E H; Laflamme, R; Negrevergne, C; Miquel, Cesar; Paz, Juan Pablo; Saraceno, Marcos; Knill, Emmanuel; Laflamme, Raymond; Negrevergne, Camille

    2001-01-01

    Determining the state of a system and measuring properties of its evolution are two of the most important tasks a physicist faces. For the first purpose one can use tomography, a method that after subjecting the system to a number of experiments determines all independent elements of the density matrix. For the second task, one can resort to spectroscopy, a set of techniques used to determine the spectrum of eigenvalues of the evolution operator. In this letter, we show that tomography and spectroscopy can be naturally interpreted as dual forms of quantum computation. We show how to adapt the simplest case of the well-known phase estimation quantum algorithm to perform both tasks, giving it a natural interpretation as a simulated scattering experiment. We show how this algorithm can be used to implement an interesting form of tomography by performing a direct measurement of the Wigner function of a quantum system. We present results of such measurements performed on a system of three qubits using liquid state...

  3. Usefulness of {sup 18}F-fluorodeoxyglucose positron emission tomography in follicular lymphoma management; Apport de la tomographie a emission de positons au {sup 18}F-fluorodeoxyglucose dans la prise en charge des lymphomes folliculaires

    Energy Technology Data Exchange (ETDEWEB)

    Le Dortz, L.; Devillers, A.; Prigent, F.; Bahri, H.; Hervouet, T.; Garin, E. [Centre Eugene-Marquis, Service de Medecine Nucleaire, 35 - Rennes (France); Guibert, S. de.; Lamy, T. [CHU de Rennes, Service d' Hematologie, 35 - Rennes (France); Rolland, Y. [Centre Eugene-Marquis, Service de Radiologie, 35 - Rennes (France); Bayat, S. [CHU de Rennes, Dept. d' Information Medicale, 35 - Rennes (France)

    2009-06-15

    Purpose To assess the usefulness of positron emission tomography/computed tomography in staging, prognosis evaluation and re staging of patients with follicular lymphoma. Patients and methods a retrospective study was performed on 45 patients with untreated biopsy-proven follicular lymphoma who underwent F.D.G.-PET/CT and CT before and after chemo-immunotherapy induction treatment (rituximab combined with cyclophosphamide, doxorubicin, vincristine and prednisone). Results PET/CT detected more nodal (+51%) and extra nodal (+89%) lesions than CT. PET/CT changed Ann Arbor stage in eight patients (18%). Five patients (11%) initially considered with early stage (I/II) were finally managed as advanced stage (III/IV). In this study, initial PET/CT was significantly more accurate to identify patients with poor prognosis than F.L.I.P.I.. Poor prognosis was defined as incomplete therapeutic response or early relapse. Accuracy of PET/CT for therapeutic response assessment was significantly higher than that of CT (0.97 vs 0.64), especially because of its ability to identify inactive residual masses. Beside, post-treatment PET/CT was able to predict patients outcome. The median progression free survival (P.F.S.) was 48 months in the PET/CT negative group as compared to 17.2 months for the group with residual uptake (P < 10-4). Conclusion F.D.G.-PET/CT is a very useful tool for staging, assessing prognosis and therapeutic response of patients with follicular lymphoma. (authors)

  4. COMPUTED TOMOGRAPHY OF TOOTH RESORPTION IN CATS.

    Science.gov (United States)

    Lang, Linda G; Wilkinson, Thomas E; White, Tammy L; Farnsworth, Raelynn K; Potter, Kathleen A

    2016-09-01

    Tooth resorption is the most common dental disease in cats and can be a source of oral pain. The current clinical gold standard for diagnosis includes a combination of oral exam and dental radiography, however early lesions are not always detected. Computed tomography (CT) of the skull, including the dental arches, is a commonly performed diagnostic procedure, however the appearance of tooth resorption on CT and the diagnostic ability of CT to detect tooth resorption have not been evaluated. The purpose of this prospective, descriptive, diagnostic accuracy study was to characterize the CT appearance of tooth resorption in a sample of affected cats and to evaluate the sensitivity and specificity of CT for tooth resorption compared to the clinical gold standard of oral exam and intraoral dental radiography. Twenty-eight cat cadaver specimens were recruited for inclusion. Each specimen was evaluated using oral exam, intraoral dental radiography, and computed tomography (four different slice thicknesses). Each tooth was evaluated for the presence or absence of tooth resorption. Teeth with lesions and a subset of normal teeth were evaluated with histopathology. On CT, tooth resorption appeared as irregularly marginated hypoattenuating defects in the mineral attenuating tooth components, most commonly involving the root or cementoenamel junction. Sensitivity for CT detection of tooth resorption was fair to poor (42.2-57.7%) and specificity was good to excellent (92.8-96.3%). Findings from this study indicated that CT has high specificity but low sensitivity for detection of tooth resorption in cats.

  5. Computed tomography in pelvic and acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Born, H.; Schmidt, C.

    1988-06-01

    In a retrospective study we analyzed the results of 127 patients, who were examined not only by means of conventional radiography but also by means of computed tomography after a trauma of the pelvic. Our investigations were based upon such patients, to whom a definite diagnostic procedure of plain radiography had been performed. Therefore all polytraumatized patients were inapplicable. They were only examined by computed tomography because of other more important accompanying injuries of other body regions. We compared the results of 127 patients with pelvic trauma. The results of the CT were in accordance with the results of the plain radiography for 103 patients. The results of the CT concerning the availability and the localization of the fractures were basically coincident with the plain radiography for 22 patients, but the CT showed a higher degree of trauma and additional intraarticular fragments. Two isolated lesions of the sacroiliac joint could not be recognized by both methods. They could only be diagnosed by bone scintigraphy on the third day after trauma.

  6. SADMFR guidelines for the use of cone-beam computed tomography/ Digital Volume Tomography

    OpenAIRE

    Dula, Karl; Bornstein, Michael M.; Buser, Daniel; Dagassan-Berndt, Dorothea; Ettlin, Dominik A; Filippi, Andreas; Gabioud, François; Katsaros, Christos; Krastl, Gabriel; Lambrecht, J. Thomas; Lauber, Roland; Luebbers, Heinz-Theo; Pazera, Pawel; Türp, Jens C.

    2014-01-01

    Cone-Beam Computed Tomography (CBCT) has been introduced in 1998. This radiological imaging procedure has been provided for dentistry and is comparable to computed tomography (CT) in medicine. It is expected that CBCT will have the same success in dental diagnostic imaging as computed tomography had in medicine. Just as CT is responsible for a significant rise in radiation dose to the population from medical X-ray diagnostics, CBCT studies will be accompanied by a significant increase of the ...

  7. Computed Tomography Technology: Development and Applications for Defence

    Science.gov (United States)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-09-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT&E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  8. Use of high-resolution computed tomography and positron emission tomography/computed tomography in the management of stage IA adenocarcinoma.

    Science.gov (United States)

    Miyata, Yoshihiro; Tsutani, Yasuhiro; Okada, Morihito

    2012-01-01

    Preoperative determination of malignant behavior is critical in choosing suitable therapeutic strategies such as sublobar resection for patients with small lung cancers. The aim of present review was to evaluate high-resolution computed tomography and fluorodeoxyglucose-positron emission tomography/computed tomography as tools for management of clinical stage IA adenocarcinoma.

  9. Spatiotemporal computed tomography of dynamic processes

    Science.gov (United States)

    Kaestner, Anders; Münch, Beat; Trtik, Pavel; Butler, Les

    2011-12-01

    Modern computed tomography (CT) equipment allowing fast 3-D imaging also makes it possible to monitor dynamic processes by 4-D imaging. Because the acquisition time of various 3-D-CT systems is still in the range of at least milliseconds or even hours, depending on the detector system and the source, the balance of the desired temporal and spatial resolution must be adjusted. Furthermore, motion artifacts will occur, especially at high spatial resolution and longer measuring times. We propose two approaches based on nonsequential projection angle sequences allowing a convenient postacquisition balance of temporal and spatial resolution. Both strategies are compatible with existing instruments, needing only a simple reprograming of the angle list used for projection acquisition and care with the projection order list. Both approaches will reduce the impact of artifacts due to motion. The strategies are applied and validated with cold neutron imaging of water desorption from originally saturated particles during natural air-drying experiments and with x-ray tomography of a polymer blend heated during imaging.

  10. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  11. Advanced proton imaging in computed tomography

    CERN Document Server

    Mattiazzo, S; Giubilato, P; Pantano, D; Pozzobon, N; Snoeys, W; Wyss, J

    2015-01-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. Proton computed tomography (pCT) scanners, currently in their R&D phase, provide the ultimate 3D imaging for hadrons treatment guidance. A key component of a pCT scanner is the detector used to track the protons, which has great impact on the scanner performances and ultimately limits its maximum speed. In this article, a novel proton-tracking detector was presented that would have higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. This advancement in performances is achieved by employing the very latest development in monolithic active pixel detectors (to build high granularity, low material budget, ...

  12. Analysis of airways in computed tomography

    DEFF Research Database (Denmark)

    Petersen, Jens

    Chronic Obstructive Pulmonary Disease (COPD) is major cause of death and disability world-wide. It affects lung function through destruction of lung tissue known as emphysema and inflammation of airways, leading to thickened airway walls and narrowed airway lumen. Computed Tomography (CT) imaging...... have become the standard with which to assess emphysema extent but airway abnormalities have so far been more challenging to quantify. Automated methods for analysis are indispensable as the visible airway tree in a CT scan can include several hundreds of individual branches. However, automation...... of scan on airway dimensions in subjects with and without COPD. The results show measured airway dimensions to be affected by differences in the level of inspiration and this dependency is again influenced by COPD. Inspiration level should therefore be accounted for when measuring airways, and airway...

  13. Findings of computed tomography in intracranial tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Jo, H. G.; Bae, K. S.; Lee, H. K.; Kwon, K. H.; Kim, K. J. [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    In intracranial tuberculosis, the Computed Tomography (CT) is a new radiological technique which is helpful in diagnosis and determining the location, extents of the lesion. It can also make it possible to assess the presence and degree of the complications and to evaluate the effectiveness of treatment. 25 cases of clinically proven intracranial tuberculosis were studied by CT, in Soonchunhyang hospital from Jun. 1980 to Jun. 1983. The result were as follows; 1. 4 cases were normal in CT finding, despite of the clinically proven tuberculous meningitis. 2. Total or partial obliteration of cisterns were observed in 13 cases. 3. Intense abnormal contrast enhancement of the cisterns were observed in 8 cases. 4. 19 cases show moderate to marked ventricular dilatation. 5. 2 cases of cerebral infarction were observed. 6. One case of tuberculoma was observed.

  14. Computed Tomography in the Modern Slaughterhouse

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb

    of technology. Recently, the use of X-ray computed tomography (CT) coupled with methods from image analysis has been introduced as a powerful means to optimise production, by providing detailed information on the raw materials. This thesis covers two aspects of the application of CT in the modern abattoir...... concerns measurements of each single carcass, to improve the raw material utilisation by individually adapted processing. Measurements performed online in the abattoir demand fast, robust and cost-effective imaging. We propose a tomographic reconstruction algorithm, enabling a substantial reduction...... of the subject-specific X-ray data needed to produce high quality images for accurate measurements. This is very beneficial for the abattoirs, as a reduction in acquired data translates directly into higher speed and a lower cost. The thesis demonstrates the great potential of CT as a technology for improving...

  15. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...... table position. Advances in reconstruction algorithms make it possible to reduce the radiation dose for each examination to acceptable levels. Regarding abdominal imaging, CT perfusion is still considered a research tool, but several studies have proven it as a reliable non-invasive technique...... for assessment of vascularity. CT perfusion has also been used for tumor characterization, staging of disease, response evaluation of newer drugs targeted towards angiogenesis and as a method for early detection of recurrence after radiation and embolization. There are several software solutions available...

  16. Computed tomography in metastatic renal cell carcinoma.

    Science.gov (United States)

    Griffin, Nyree; Grant, Lee Alexander; Bharwani, Nishat; Sohaib, S Aslam

    2009-08-01

    Recent developments in chemotherapy have resulted in several new drug treatments for metastatic renal cell carcinoma (RCC). These therapies have shown improved progression-free survival and are applicable to many more patients than the conventional cytokine-based treatments for metastatic RCC. Consequently imaging is playing a greater part in the management of such patients. Computed tomography (CT) remains the primary imaging modality with other imaging modalities playing a supplementary role. CT is used in the diagnosis and staging of metastatic RCC. It is used in the follow-up of patients after nephrectomy, in assessing the extent of metastatic disease, and in evaluating response to treatment. This review looks at the role of CT in patients with metastatic RCC and describes the appearances of metastatic RCC before and following systemic therapy.

  17. Reconstructing cetacean brain evolution using computed tomography.

    Science.gov (United States)

    Marino, Lori; Uhen, Mark D; Pyenson, Nicholas D; Frohlich, Bruno

    2003-05-01

    Until recently, there have been relatively few studies of brain mass and morphology in fossil cetaceans (dolphins, whales, and porpoises) because of difficulty accessing the matrix that fills the endocranial cavity of fossil cetacean skulls. As a result, our knowledge about cetacean brain evolution has been quite limited. By applying the noninvasive technique of computed tomography (CT) to visualize, measure, and reconstruct the endocranial morphology of fossil cetacean skulls, we can gain vastly more information at an unprecedented rate about cetacean brain evolution. Here, we discuss our method and demonstrate it with several examples from our fossil cetacean database. This approach will provide new insights into the little-known evolutionary history of cetacean brain evolution.

  18. Computed tomography findings of malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Shiota, Yutaro; Sato, Toshio; Yamaguchi, Kazuo; Ono, Tetsuya; Kaji, Masaro; Niiya, Harutaka (Kure Kyosai Hospital, Hiroshima (Japan))

    1994-04-01

    Computed tomography (CT) findings were assessed in 7 patients with malignant mesothelioma. CT findings were also reviewed in 9 patients with lung cancer and pleuritis carcinomatosa and in 11 patients with tuberculous pleuritis. Five patients with malignant mesothelioma underwent CT scans twice, on admission and from 1 to 7 months after admission. Tuberculous pleuritis could be distinguished from pleuritis carcinomatosa and malignant mesothelioma by the presence or absence of pleural nodularity and chest wall invasion. Although it was difficult to identify specific CT features clearly distinguishing malignant mesothelioma from pleuritis carcinomatosa, characteristic findings of malignant mesothelioma appeared to include the rapid development and progression of pleural rind and a tendency to spread directly into the chest wall. We divided the pleural into the four regions; upper anterior, upper posterior, lower anterior and lower posterior regions. Pleural changes were more frequently seen in the lower pleural regions than in the upper pleural regions in malignant mesothelioma. (author).

  19. Ultra-high resolution computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Knoxville, TN); Tobin, Jr., Kenneth William (Harriman, TN); Gleason, Shaun S. (Knoxville, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2002-01-01

    A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.

  20. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...... - CIA-CT”. In the comparison, 27 laboratories from 8 countries were involved, and CT scanned two items selected among common industrial parts: a polymer part and a metal part. Altogether, 27 sets of items were circulated in parallel to the participants. Different measurands are considered, encompassing...... influence from the surrounding wall thickness on the measurement of roundness was documented for the metal item. The comparison shows that CT scanning on small industrial parts, generally speaking, is connected with uncertainties in the range 8-53 μm, as compared to an uncertainty range of 1.5-5.5 μm using...

  1. Intravenous coronary angiography using electron beam computed tomography

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A H; van Geuns, R J; van Ooijen, P M; Oudkerk, M; de Feyter, P J

    1999-01-01

    Intravenous coronary angiography with electron beam computed tomography (EBCT) allows for the noninvasive visualisation of coronary arteries. With dedicated computer hardware and software, three-dimensional renderings of the coronary arteries, veins, and other cardiac structures can be constructed f

  2. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  3. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J.N.; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  4. Computed tomography in traumatic defects of the diaphragm.

    Science.gov (United States)

    Demos, T C; Solomon, C; Posniak, H V; Flisak, M J

    1989-03-01

    Two patients with traumatic diaphragmatic defects visible on computed tomography are presented. The diagnosis was delayed for several years in both patients. The diagnosis of these acquired diaphragmatic defects is often difficult. Computed tomography can lead to earlier diagnosis by demonstrating the defect in some patients when radiographic studies are not diagnostic.

  5. Diagnosis of lumbar disc hernia with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizumi, Atsuro; Ohira, Nobuhiro; Ojima, Tadashi; Oshida, Midori; Horaguchi, Mitsuru (Tohoku Rosai Hospital, Sendai (Japan))

    1982-07-01

    Results of computed tomography performed on patients with clinically diagnosed hernia were compared with those of myelography and operative findings. This comparative study suggested that computed tomography is quite different from other methods and very useful in diagnosis of hernia. Some cases of hernia were shown, and the characteristics of CT were reviewed.

  6. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on t

  7. X-Ray Computed Tomography for Advanced Materials and Processes.

    Science.gov (United States)

    1992-06-30

    percent. In this example, we have assumed $I M, $5(X)K and $200K CT systems operating at 10 percent of the capital investment per year for maintenance...Computed Tomo &:aphy of Composites," WRDC-TR-90-4014, July 1990. 5. P. Burstein and R. H. Bossi, "A Guide to Computed Tomography System Specifications," WRDC...Lannutti, "Applications of High- Resolution Computed Tomography," Proceedings of the 1991 Industrial Computed Tomography II Topical Conference, May 20-24

  8. Computed tomography of posterior pararenal and properitoneal metastases.

    Science.gov (United States)

    Posniak, H V; Tempany, C; Demos, T C; Love, L

    1988-01-01

    Identification of the retroperitoneal fascial planes with modern computed tomographic scanners allows for precise localization of pathologic processes in the individual compartments of the retroperitoneum. Metastatic disease to the posterior pararenal space or properitoneal space in 6 patients is reported. Two patients had diffuse histiocytic lymphoma and 4 had metastatic melanoma.

  9. Micro computed tomography for vascular exploration

    Directory of Open Access Journals (Sweden)

    Zhuang Zhen W

    2010-03-01

    Full Text Available Abstract Vascular exploration of small animals requires imaging hardware with a very high spatial resolution, capable of differentiating large as well as small vessels, in both in vivo and ex vivo studies. Micro Computed Tomography (micro-CT has emerged in recent years as the preferred modality for this purpose, providing high resolution 3D volumetric data suitable for analysis, quantification, validation, and visualization of results. The usefulness of micro-CT, however, can be adversely affected by a range of factors including physical animal preparation, numerical quantification, visualization of results, and quantification software with limited possibilities. Exacerbating these inherent difficulties is the lack of a unified standard for micro-CT imaging. Most micro-CT today is aimed at particular applications and the software tools needed for quantification, developed mainly by imaging hardware manufacturers, lack the level of detail needed to address more specific aims. This review highlights the capabilities of micro-CT for vascular exploration, describes the current state of imaging protocols, and offers guidelines and suggestions aimed at making micro-CT more accurate, replicable, and robust.

  10. Radiation doses from computed tomography in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, J.E.M.; Tingey, D.R.C

    1997-11-01

    Recent surveys in various countries have shown that computed tomography (CT) is a significant and growing contributor to the radiation dose from diagnostic radiology. Australia, with 332 CT scanners (18 per million people), is well endowed with CT equipment compared to European countries (6 to 13 per million people). Only Japan, with 8500 units (78 per million people), has a significantly higher proportion of CT scanners. In view of this, a survey of CT facilities, frequency of examinations, techniques and patient doses has been performed in Australia. It is estimated that there are 1 million CT examinations in Australia each year, resulting in a collective effective dose of 7000 Sv and a per caput dose of 0.39 mSv. This per caput dose is much larger than found in earlier studies in the UK and New Zealand but is less than 0.48 mSv in Japan. Using the ICRP risk factors, radiation doses from CT could be inducing about 280 fatal cancers per year in Australia. CT is therefore a significant, if not the major, single contributor to radiation doses and possible risk from diagnostic radiology. (authors) 28 refs., 11 tabs., 10 figs.

  11. Dedicated breast computed tomography: Basic aspects

    Energy Technology Data Exchange (ETDEWEB)

    Sarno, Antonio; Mettivier, Giovanni, E-mail: mettivier@na.infn.it; Russo, Paolo [Dipartimento di Fisica, Università di Napoli Federico II, Via Cintia, Napoli I-80126, Italy and INFN Sezione di Napoli, Napoli I-80126 (Italy)

    2015-06-15

    X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

  12. Computed tomography characterisation of additive manufacturing materials.

    Science.gov (United States)

    Bibb, Richard; Thompson, Darren; Winder, John

    2011-06-01

    Additive manufacturing, covering processes frequently referred to as rapid prototyping and rapid manufacturing, provides new opportunities in the manufacture of highly complex and custom-fitting medical devices and products. Whilst many medical applications of AM have been explored and physical properties of the resulting parts have been studied, the characterisation of AM materials in computed tomography has not been explored. The aim of this study was to determine the CT number of commonly used AM materials. There are many potential applications of the information resulting from this study in the design and manufacture of wearable medical devices, implants, prostheses and medical imaging test phantoms. A selection of 19 AM material samples were CT scanned and the resultant images analysed to ascertain the materials' CT number and appearance in the images. It was found that some AM materials have CT numbers very similar to human tissues, FDM, SLA and SLS produce samples that appear uniform on CT images and that 3D printed materials show a variation in internal structure.

  13. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  14. Computed Tomography Following Body Stuffing Heroin

    Directory of Open Access Journals (Sweden)

    Sean P. Nordt

    2015-12-01

    Full Text Available A 37-year-old male presented to the emergency department (ED in police custody for “medical clearance” before being taken to jail. The patient was approached by police officers for suspicion of selling illicit drugs. When approached by police he ran away and was witnessed to swallow several small plastic baggies suspected to contain heroin. He was apprehended and brought to the ED. On arrival, he was asymptomatic with a blood pressure 144/83mmHg, heart rate 67bpm, respiratory rate of 19bpm, oxygen saturation of 99% on room air and afebrile. A Glasgow coma score was 15 and he was alert and oriented to person, place and time. Patient had a negative review of systems. On physical examination pupils were 4mm and reactive to light, lungs clear to auscultation and had normal respiratory rate with normal cardiovascular exam. Abdomen was soft, non-tender and non-distended with present bowel sounds. The patient admitted to ingesting approximately 20 packets of heroin to avoid being charged with possession. The patient declined activated charcoal and whole bowel irrigation (WBI with polyethylene glycol-electrolyte solution (PEG-ELS. The patient declined a urine toxicology immunoassay screen. A computed tomography (CT of his abdomen with contrast was obtained and read as normal except for a cluster of foreign bodies within the distal stomach likely contained within a plastic bag.

  15. Virtual computed tomography cystoscopy in bladder pathologies

    Directory of Open Access Journals (Sweden)

    Halil Arslan

    2006-04-01

    Full Text Available OBJECTIVE: Assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT in patients with different urinary bladder pathologies compared to the conventional cystoscopy. MATERIALS AND METHODS: Eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. RESULTS: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88% of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. CONCLUSION: Virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion.

  16. Virtual computed tomography cystoscopy in bladder pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban [Yuzuncu Yil University School of Medicine, Van (Turkey). Dept. of Radiology and Urology]. E-mail: drhalilarslan@hotmail.com

    2006-03-15

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  17. Application of computed tomography to spinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Sha, N.; Kurihara, A.; Kataoka, O. (Kobe Univ. (Japan). School of Medicine)

    1980-08-01

    The axial tomographic examination of the spine and its soft tissues is now readily available for orthopaedic surgery. If the appropriate conditions are maintained, computed tomography (CT) can provide useful information concerning the diagnosis and the treatment of spinal diseases. There are, however, some pitfalls in interpreting CT scans: 1) the existence of the lesion may be masked, and 2) its extent and configuration may be over- or under-evaluated depending on such technical factors as the slicing level, the slicing angle, the window width, and the window level. Experimental studies were carried out on a plaster of Paris model of the spine and a cadaver spine to determine the appropriate technical factors by which the CT (EMI whole body CT scanner 5005) can be applied accurately to a diseased spine. The factors obtained were then applied in examining ninety-nine patients with various spinal disorders. Window levels ranging between 100 and 150 were found to be most appropriate. The slicing angle should be 90/sup 0/, or perpendicular to the long axis of the object under study. However, deviations of +10 or -10 degrees are acceptable. The CT view of the spine may be divided into two patterns at the cervical and thoracic levels and into three patterns at the lumbar level. In addition, the usefulness and the diagnostic value of CT for various spinal problems are discussed based on our clinical material.

  18. Computed tomography in acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, Karl-Olof [HUG-Geneva University Hospital, Geneva University Medical School, Department of Neuroradiology, Department of Imaging and Medical Informatics, Geneva (Switzerland); Baird, Alison E. [SUNY Downstate Medical Center, Cerebrovascular Disease and Stroke, 450 Clarkson Avenue, Box 1213, Brooklyn, NY (United States)

    2010-03-15

    Stroke remains the third most important cause of mortality in industrialized countries; this has prompted research for improvements in both diagnostic and therapeutic strategies for patients with signs of acute cerebral ischemia. Over the last decade, there has been a parallel in progress in techniques in both diagnostic and therapeutic options. While previously only used for excluding hemorrhage, imaging now has the possibility to detect ischemia, vascular occlusion, as well as detect tissue at risk in one setting. It should also allow to monitor treatment and predict/exclude therapeutic complications. Parallel to advances in magnetic resonance imaging of stroke, computed tomography has improved immensely over the last decade due to the development of CT scanners that are faster and that allow to acquire studies such as CT perfusion or CT angiography in a reliable way. CT can detect many signs that might help us detect impending signs of massive infarction, but we still lack the experience to use these alone to prevent a patient from benefitting from possible therapy. (orig.)

  19. Application of computed tomography in paleoanthropological research

    Institute of Scientific and Technical Information of China (English)

    Xiujie Wu; Lynne A.Schepartz

    2009-01-01

    Hominin fossils are the most important materials for exploring questions about human origins and evolution. Because human fossils are very rare, it is impossible to use highly destructive techniques in order to study their morphology. Traditional analyses can only rely on the information gained from the study of the external morphology of specimens, and these approaches limited the study of human evolution. The application of computed tomography (CT) has facilitated major developments in paleoanthropology. To date, few studies on Chinese hominin fossils have used CT scanning methodology, but this is rapidly changing. In order to better understand the appli-cation of CT methodology in paleoanthropology, we review the applications of CT scanning on hominin fossils throughout the world.Studies examined include virtual fossil reconstruction, the use of endocasts to elucidate brain morphology, biomechanical analyses of bone distribution, imaging of mummies and research on early human health, and skeletal and dental microanatomical research.2009 National Natural Science Foundation of China and Chinese Academy of Sciences. Published by Elsevier Limited and Science in China Press. All rights reserved.

  20. Computed tomography of the orbital lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Eon; Suh, Soo Jhi; Kim, Ho Kyun; Kim, Soon Yong [Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    1980-06-15

    The use of computed tomography in investigation of orbital lesions was of value for the localization of the lesions as well as making the specific diagnosis. We advocated the combined use of transverse axial section and contrast enhancement in CT as a routine procedure often including coronal section in the diagnosis of orbital lesions because of its usefulness and more precise three dimensional imaging. The authors examined 68 patients with various ophthalmic problems by EMI-CT scanner 5005 from October 1977 to November 1979. Fifty one orbital lesions out of 68 CT scans were analyzed by CT, angiography and operative findings and results were as follows; 1. Among 43 males and 25 females, their age range was from 4 months to 66 years with the most frequent age group of first decade (17 cases; 25%) 2. The distribution of the lesions was mucocele, pseudotumor, optic nerve atrophy, metastasis, lacrimal gland tumor, persistent hypertrophic primary vitreous, granulosa cell myoblastoma, hemangioma in order with 13 malignancies (25%). 3. It was difficult to differentiate pathological diagnosis of the lesions, but the character of the lesions was determined by its characteristic location, and its relationship to eyeball, optic nerve, extraocular muscles and bony orbit. 4. It was thought that more accurate diagnosis of orbital lesions could be made by development of CT scanner having fine matrix, short time exposure and thin slice in the future.

  1. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  2. Gradient computation for VTI acoustic wavefield tomography

    KAUST Repository

    Li, Vladimir

    2016-09-06

    Wavefield tomography can handle complex subsurface geology better than ray-based techniques and, ultimately, provide a higher resolution. Here, we implement forward and adjoint wavefield extrapolation for VTI (transversely isotropic with a vertical symmetry axis) media using a pseudospectral operator that employes a separable approximation of the P-wave dispersion relation. This operator is employed to derive the gradients of the differential semblance optimization (DSO) and modified stack-power objective functions. We also obtain the gradient expressions for the data-domain objective function, which can incorporate borehole information necessary for stable VTI velocity analysis. These gradients are compared to the ones obtained with a space-time finite-difference (FD) scheme for a system of coupled wave equations. Whereas the kernels computed with the two wave-equation operators are similar, the pseudospectral method is not hampered by the imprint of the shear-wave artifact. Numerical examples also show that the modified stack-power objective function produces cleaner gradients than the more conventional DSO operator.

  3. Perfusion computed tomography in renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Chandan; J; Das; Usha; Thingujam; Ananya; Panda; Sanjay; Sharma; Arun; Kumar; Gupta

    2015-01-01

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma(RCC). While contrast enhanced computed tomography(CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT(p CT), goes down to the molecular level and provides new perspectives in imaging of RCC. p CT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using p CT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of p CT in staging and response assessment in patients with RCCs.

  4. REVIEW: X-ray computed tomography

    Science.gov (United States)

    Kalender, Willi A.

    2006-07-01

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.

  5. Computer tomography-aided ventriculography and cisternography

    Energy Technology Data Exchange (ETDEWEB)

    Cernoch, Z.; Sercl, M.; Heger, L.; Parizek, J. (Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta)

    1983-01-28

    Computer tomography was used in 42 patients for the exploration of ventricular and subarachnoidal spaces following intraventricular, lumbar or suboccipital injections of 3 to 5 ml Amipaque using the kind of manoeuvre to permit optimum filling of the region concerned. This type of CT ventriculo- or cisternography is a significant supplement to plain CT examination particularly because it supplies data on the causes of CSF passage blocks. Thus, in two female patients it proved possible to localize cysts in the 3rd ventricle, the density of which was no different from that of CSF. As regards benign stenoses of the aqueduct, it is likely to yield less information than conventional specific ventriculography. On the other hand, the technique gives perfect visualization of all possible communications between pathological intracranial cavities and the ventricular system. CT cisternography proved useful for the identification of small-size isodense growths in the region of the sella turcica, and brought convincing evidence of the causes of profuse liquorrhea by demonstrating the presence of nasal meningocele. It was also found helpful in the analysis of the craniocervical region, otherwise difficult to survey.

  6. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  7. A Detector for Proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blazey, G.; et al.

    2013-12-06

    Radiation therapy is a widely recognized treatment for cancer. Energetic protons have distinct features that set them apart from photons and make them desirable for cancer therapy as well as medical imaging. The clinical interest in heavy ion therapy is due to the fact that ions deposit almost all of their energy in a sharp peak – the Bragg peak- at the very end of their path. Proton beams can be used to precisely localize a tumor and deliver an exact dose to the tumor with small doses to the surrounding tissue. Proton computed tomography (pCT) provides direct information on the location on the target tumor, and avoids position uncertainty caused by treatment planning based on imaging with X-ray CT. The pCT project goal is to measure and reconstruct the proton relative stopping power distribution directly in situ. To ensure the full advantage of cancer treatment with 200 MeV proton beams, pCT must be realized.

  8. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  9. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings*

    Science.gov (United States)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tânia Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanês, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mário Flores

    2015-01-01

    Objective To evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and Methods Retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results Abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion Computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. PMID:25987748

  10. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  11. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which ena...

  12. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  13. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    2005-01-01

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic mo

  14. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  15. Positron emission tomography/computed tomography for optimized colon cancer staging and follow up

    DEFF Research Database (Denmark)

    Engelmann, Bodil Elisabeth; Loft, Annika; Kjær, Andreas;

    2014-01-01

    OBJECTIVES: Optimal management of colon cancer (CC) requires detailed assessment of extent of disease. This study prospectively investigates the diagnostic accuracy of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (PET/CT) for staging and detection of recurrence...

  16. The Use of GPUs for Solving the Computed Tomography Problem

    Directory of Open Access Journals (Sweden)

    A.E. Kovtanyuk

    2014-07-01

    Full Text Available Computed tomography (CT is a widespread method used to study the internal structure of objects. The method has applications in medicine, industry and other fields of human activity. In particular, Electronic Imaging, as a species CT, can be used to restore the structure of nanosized objects. Accurate and rapid results are in high demand in modern science. However, there are computational limitations that bound the possible usefulness of CT. On the other hand, the introduction of high-performance calculations using Graphics Processing Units (GPUs provides improving quality and performance of computed tomography investigations. Moreover, parallel computing with GPUs gives significantly higher computation speeds when compared with (Central Processing Units CPUs, because of architectural advantages of the former. In this paper a computed tomography method of recovering the image using parallel computations powered by NVIDIA CUDA technology is considered. The implementation of this approach significantly reduces the required time for solving the CT problem.

  17. Single-photon emission computed tomography/computed tomography in brain tumors.

    Science.gov (United States)

    Schillaci, Orazio; Filippi, Luca; Manni, Carlo; Santoni, Riccardo

    2007-01-01

    Anatomic imaging procedures (computed tomography [CT] and magnetic resonance imaging [MRI]) have become essential tools for brain tumor assessment. Functional images (positron emission tomography [PET] and single-photon emission computed tomography [SPECT]) can provide additional information useful during the diagnostic workup to determine the degree of malignancy and as a substitute or guide for biopsy. After surgery and/or radiotherapy, nuclear medicine examinations are essential to assess persistence of tumor, to differentiate recurrence from radiation necrosis and gliosis, and to monitor the disease. The combination of functional images with anatomic ones is of the utmost importance for a full evaluation of these patients, which can be obtained by means of imaging fusion. Despite the fast-growing diffusion of PET, in most cases of brain tumors, SPECT studies are adequate and provide results that parallel those obtained with PET. The main limitation of SPECT imaging with brain tumor-seeking radiopharmaceuticals is the lack of precise anatomic details; this drawback is overcome by the fusion with morphological studies that provide an anatomic map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT or MRI demonstrated usefulness for brain tumor assessment, but this process is often time consuming and not practical for everyday nuclear medicine studies. The recent development of dual-modality integrated imaging systems, which allow the acquisition of SPECT and CT images in the same scanning session, and their co-registration by means of the hardware, has facilitated this process. In SPECT studies of brain tumors with various radiopharmaceuticals, fused images are helpful in providing the precise localization of neoplastic lesions, and in excluding the disease in sites of physiologic tracer uptake. This information is useful for optimizing diagnosis, therapy monitoring, and radiotherapy treatment planning, with a

  18. Computed tomography (CT) and diastematomyelia's diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Santos, M.B. dos; Luca, V. de; Ferreira, M.A.S. (Rio de Janeiro Univ. (Brazil). Faculdade de Medicina); Barros, A.P. de (Rio de Janeiro Univ. (Brazil). Hospital Universitario)

    After a case of diastematomyelia observed at the University Hospital (Federal University of Rio de Janeiro, Brazil) a review is done of the pertaining literature, and the contribution of the computed tomography for the diagnosis of this disease is emphasized.

  19. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  20. Perfusion computed tomography to assist decision making for stroke thrombolysis

    Science.gov (United States)

    Levi, Christopher; Krishnamurthy, Venkatesh; McElduff, Patrick; Miteff, Ferdi; Spratt, Neil J.; Bateman, Grant; Donnan, Geoffrey; Davis, Stephen; Parsons, Mark

    2015-01-01

    The use of perfusion imaging to guide selection of patients for stroke thrombolysis remains controversial because of lack of supportive phase three clinical trial evidence. We aimed to measure the outcomes for patients treated with intravenous recombinant tissue plasminogen activator (rtPA) at a comprehensive stroke care facility where perfusion computed tomography was routinely used for thrombolysis eligibility decision assistance. Our overall hypothesis was that patients with ‘target’ mismatch on perfusion computed tomography would have improved outcomes with rtPA. This was a prospective cohort study of consecutive ischaemic stroke patients who fulfilled standard clinical/non-contrast computed tomography eligibility criteria for treatment with intravenous rtPA, but for whom perfusion computed tomography was used to guide the final treatment decision. The ‘real-time’ perfusion computed tomography assessments were qualitative; a large perfusion computed tomography ischaemic core, or lack of significant perfusion lesion-core mismatch were considered relative exclusion criteria for thrombolysis. Specific volumetric perfusion computed tomography criteria were not used for the treatment decision. The primary analysis compared 3-month modified Rankin Scale in treated versus untreated patients after ‘off-line’ (post-treatment) quantitative volumetric perfusion computed tomography eligibility assessment based on presence or absence of ‘target’ perfusion lesion-core mismatch (mismatch ratio >1.8 and volume >15 ml, core perfusion computed tomography-selected rtPA-treated patients to an Australian historical cohort of non-contrast computed tomography-selected rtPA-treated patients. Of 635 patients with acute ischaemic stroke eligible for rtPA by standard criteria, thrombolysis was given to 366 patients, with 269 excluded based on visual real-time perfusion computed tomography assessment. After off-line quantitative perfusion computed tomography classification

  1. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  2. Computed tomography and childhood seizure disorder in Ibadan ...

    African Journals Online (AJOL)

    Computed tomography and childhood seizure disorder in Ibadan. ... AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING ... the subjects who had cranial scans done in five years were children with seizures disorders.

  3. Optimisation of post mortem cardiac computed tomography compared to optical coherence tomography and histopathology - Technical note

    DEFF Research Database (Denmark)

    Precht, Helle; Leth, Peter Mygind; Thygesen, Jesper

    2014-01-01

    Introduction: Coronary atherosclerosis is a leading cause of mortality. New technological developments in computed tomography (CT), including dual energy, iterative reconstructions and high definition scanning, could significantly improve the non-invasive identification of atherosclerosis plaques...

  4. Cone beam computed tomography in Endodontics - a review.

    Science.gov (United States)

    Patel, S; Durack, C; Abella, F; Shemesh, H; Roig, M; Lemberg, K

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on the applications and limitations of CBCT; (ii) make recommendations for the use of CBCT in Endodontics; (iii) highlight areas of further research of CBCT in Endodontics. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  5. A Clinical Evaluation of Cone Beam Computed Tomography

    Science.gov (United States)

    2013-07-31

    multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 2011;40:67-75...submitted to the Faculty of the Endodontics Graduate Program Naval Postgraduate Dental School Uniformed Services University of the Health Sciences...in partial fulfillment of the requirements of the degree of Master of Science in Oral Biology June 2013 Naval Postgraduate Dental

  6. Computed tomography of the mediastinum in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Guertler, K.F.; Janzen, R.W.C.; Hagemann, J.; Otto, H.F.

    1982-01-01

    Computed tomography of the mediastinum was performed in 45 patients with myasthenia gravis. Surgery was carried out in fourteen. Amongst these, there were four thymomas, one thymolipoma, eight thymic hyperplasias and one normal thymus gland. A further patient, who did not have surgery, probably also had a thymic tumour. The normal thymus and thymic hyperplasia cannot be distinguished on computed tomography. Differentiation of small thymomas from normal thymus is not always possible. Invasion by thymomas can only be appreciated with large tumours.

  7. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints. Vergleich von konventioneller Tomographie und Computertomographie bei Erkrankungen der Sakroiliakalgelenke

    Energy Technology Data Exchange (ETDEWEB)

    Moritz, J.D.; Ganter, H.; Winter, C. (Bundeswehrkrankenhaus, Giessen (Germany, F.R.). Roentgenabteilung Evangelisches Krankenhaus, Giessen (Germany, F.R.). Roentgenabteilung)

    1990-10-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.).

  8. Burkitt lymphoma as a cause of intussusceptions: The significance of positron emission tomography scan in the follow-up

    Directory of Open Access Journals (Sweden)

    Radovanović Zoran

    2017-01-01

    Full Text Available Introduction. Burkitt lymphoma (BL is a high-grade, highrisk type of non-Hodgkin lymphoma characterized by a very rapid cell progression. Although BL is a rare cause of intussusceptions, it must arouse suspicion if the intussusception occurs outside the characteristic peak. Case report. A previously healthy 7-year-old boy was hospitalized for recurrent abdominal pain, loss of appetite and body weight, a fever of up to 38°C, persistent vomiting and with soft tumefaction ileocecally. Nuclear magnetic resonance (NMR revealed intussusceptions due to a tumor mass, which was followed by a surgical procedure (right hemicolectomy and terminoterminal anastomosis. Histopathological examination confirmed the diagnosis of primary abdominal Burkitt lymphoma. In spite of the subsequent oncologic treatment lasting for four months, an undifferentiated mass was detected in the retroperitoneal space below the lower pole of the right kidney. Positron emission tomography (PET scan was performed in order to detect the metabolic activity of the deposit in the retroperitoneal space. A high metabolic activity of Burkitt lymphoma confirmed its presence, as well as the need for additional surgical intervention for tumor extirpation. PET scan undoubtedly contributed to distinguishing the visibility of tumor cells and to the detection of the subcentimeter tumor mass. Conclusion. The timely diagnosis, high tumor sensitivity to chemotherapy as well as the great importance of PET scan in the early detection of tumor recurrence, significantly increase the survival rate in patients with BL.

  9. Insufficiency of Positron Emission Tomography and Magnetic Resonance Spectroscopy in the Diagnosis of Intravascular Lymphoma of the Central Nervous System

    Directory of Open Access Journals (Sweden)

    Nobuyuki Kawai

    2012-07-01

    Full Text Available Intravascular large B-cell lymphoma (IVL is a rare type of extranodal lymphoma with an aggressive clinical course characterized by the proliferation of lymphoma cells within the lumen of small vessels. Diagnosis is often difficult because of marked variability in clinical presentation and nonspecific laboratory and radiological findings, especially when central nervous system (CNS symptoms are the only manifestation. Modern metabolic imaging techniques such as positron emission tomography (PET and 1H-magnetic resonance spectroscopy (MRS have been reported to be useful in the diagnosis of conventional primary CNS lymphoma. We report the case of a 69-year-old man who presented with a progressive leukoencephalopathic syndrome. The patient was examined by 18F-fluorodeoxyglucose and 11C-methionine PET and MRS, but none of these examinations were able to show the presence of a tumor in the lesions or to clarify the tumor characteristics. Brain biopsy was the only way to obtain a definite diagnosis of IVL. The patient was treated intensively with standard immunochemotherapy but died 6 months after the diagnosis. Here, we discuss the insufficiency of modern metabolic imaging techniques, including PET and MRS, and recommend a rapid decision of brain biopsy in the diagnosis of IVL only involving the CNS.

  10. Incidence of blunt craniocervical artery injuries: use of whole-body computed tomography trauma imaging with adapted computed tomography angiography.

    Science.gov (United States)

    Fleck, Steffen K; Langner, Soenke; Baldauf, Joerg; Kirsch, Michael; Kohlmann, Thomas; Schroeder, Henry W S

    2011-09-01

    The incidence of traumatic craniocervical artery dissection varies in published trauma series. To determine the frequency of traumatic craniocervical artery injury in polytrauma patients by using standardized whole-body trauma computed tomography with adapted computed tomography angiography of the craniocervical vessels. A total of 718 consecutive patients requiring whole-body trauma computed tomography (16-row multislice) because of the mechanism of their injury patterns and an Injury Severity Scale score greater than 16 were analyzed prospectively. After a cranial scan, computed tomography angiography of the craniocervical vessels with 40 mL of iodinated contrast agent was performed using bolus tracking. The overall incidence of blunt carotid and vertebral injuries (BCVIs) in the screened population was 1.7%. BCVIs were observed in 27.3% of patients with detected isolated cervical spine injuries and in 3.9% of patients with isolated cranial fractures with or without intracranial hemorrhage, whereas 5.3% of patients with combined cervical and cranial lesions were associated with BCVIs. In addition, 0.4% of BCVIs occurred in patients without evidence of head or neck trauma. Whole-body trauma computed tomography with an adapted scanning protocol for the craniocervical vessels is a fast, safe, and feasible method for detecting vascular injuries. It allows prompt further treatment if necessary. Computed tomography angiography could be a part of a broad screening protocol for craniocervical vessels in documented injuries of the head and neck and in trauma mechanisms influencing the craniocervical region as well.

  11. FDG-PET/CT in lymphoma

    Science.gov (United States)

    D'souza, Maria M; Jaimini, Abhinav; Bansal, Abhishek; Tripathi, Madhavi; Sharma, Rajnish; Mondal, Anupam; Tripathi, Rajendra Prashad

    2013-01-01

    Lymphomas are a heterogeneous group of diseases that arise from the constituent cells of the immune system or from their precursors. 18F-fludeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) is now the cornerstone of staging procedures in the state-of-the-art management of Hodgkin's disease and aggressive non-Hodgkin's lymphoma. It plays an important role in staging, restaging, prognostication, planning appropriate treatment strategies, monitoring therapy, and detecting recurrence. However, its role in indolent lymphomas is still unclear and calls for further investigational trials. The protean PET/CT manifestations of lymphoma necessitate a familiarity with the spectrum of imaging findings to enable accurate diagnosis. A meticulous evaluation of PET/CT findings, an understanding of its role in the management of lymphomas, and knowledge of its limitations are mandatory for the optimal utilization of this technique. PMID:24604942

  12. Foveola pharyngea - demonstration in conventional tomography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fiegler, W.; Stolle, E.

    1980-08-01

    The foveola pharyngea is a cavity on the underside of the clivus, located before the tuberculum pharyngeum and, as a larger pit it was detectable in approx. 1% overall in approx. 4% of the personally examined X-rays (11/284) and computed tomograms (6/154) of the skull base. The canalis basilaris medianus inferior and canalis basilaris medianus bifurcatus almost always empties into one of the three forms of the foveola pharyngea (foveola pharyngea infundibuliformis posterior). The differential diagnosis to canalis basilaris medianus, canalis craniopharyngeus, sutura sphenooccipitalis and bone destruction is discussed.

  13. Development of a proton Computed Tomography Detector System

    CERN Document Server

    Naimuddin, Md; Blazey, G; Boi, S; Dyshkant, A; Erdelyi, B; Hedin, D; Johnson, E; Krider, J; Rukalin, V; Uzunyan, S A; Zutshi, V; Fordt, R; Sellberg, G; Rauch, J E; Roman, M; Rubinov, P; Wilson, P

    2015-01-01

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  14. Development of a proton Computed Tomography Detector System

    Energy Technology Data Exchange (ETDEWEB)

    Naimuddin, Md. [Delhi U.; Coutrakon, G. [Northern Illinois U.; Blazey, G. [Northern Illinois U.; Boi, S. [Northern Illinois U.; Dyshkant, A. [Northern Illinois U.; Erdelyi, B. [Northern Illinois U.; Hedin, D. [Northern Illinois U.; Johnson, E. [Northern Illinois U.; Krider, J. [Northern Illinois U.; Rukalin, V. [Northern Illinois U.; Uzunyan, S. A. [Northern Illinois U.; Zutshi, V. [Northern Illinois U.; Fordt, R. [Fermilab; Sellberg, G. [Fermilab; Rauch, J. E. [Fermilab; Roman, M. [Fermilab; Rubinov, P. [Fermilab; Wilson, P. [Fermilab

    2016-02-04

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  15. Development of a proton Computed Tomography detector system

    Science.gov (United States)

    Naimuddin, Md.; Coutrakon, G.; Blazey, G.; Boi, S.; Dyshkant, A.; Erdelyi, B.; Hedin, D.; Johnson, E.; Krider, J.; Rukalin, V.; Uzunyan, S. A.; Zutshi, V.; Fordt, R.; Sellberg, G.; Rauch, J. E.; Roman, M.; Rubinov, P.; Wilson, P.

    2016-02-01

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  16. Evaluating iterative reconstruction performance in computed tomography.

    Science.gov (United States)

    Chen, Baiyu; Ramirez Giraldo, Juan Carlos; Solomon, Justin; Samei, Ehsan

    2014-12-01

    Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed to evaluate the performance of IR with both task-specific and task-generic strategies. The performance of IR in CT was mathematically assessed with an observer model that predicted the detection accuracy in terms of the detectability index (d'). d' was calculated based on the properties of the image noise and resolution, the observer, and the detection task. The characterizations of image noise and resolution were extended to accommodate the nonlinearity of IR. A library of tasks was mathematically modeled at a range of sizes (radius 1-4 mm), contrast levels (10-100 HU), and edge profiles (sharp and soft). Unique d' values were calculated for each task with respect to five radiation exposure levels (volume CT dose index, CTDIvol: 3.4-64.8 mGy) and four reconstruction algorithms (filtered backprojection reconstruction, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 3 and 5, SAFIRE3 and SAFIRE5; all provided by Siemens Healthcare, Forchheim, Germany). The d' values were translated into the areas under the receiver operating characteristic curve (AUC) to represent human observer performance. For each task and reconstruction algorithm, a threshold dose was derived as the minimum dose required to achieve a threshold AUC of 0.9. A task-specific dose reduction potential of IR was calculated as the difference between the threshold doses for IR and FBP. A task-generic comparison was further made between IR and FBP in terms of the percent of all tasks yielding an AUC higher than the threshold. IR required less dose than FBP to achieve the threshold AUC. In general, SAFIRE5 showed the most significant dose reduction potentials (11-54 mGy, 77%-84%), followed by

  17. Multimodality imaging of cardiothoracic lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Carter, Brett W., E-mail: bcarter2@mdanderson.org [The University of Texas MD Anderson Cancer Center, Department of Diagnostic Radiology, Section of Thoracic Imaging, 1515 Holcombe Blvd., Unit 1478, Houston, TX 77030 (United States); Wu, Carol C. [Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, FND-202, Boston, MA 02114 (United States); Khorashadi, Leila [Department of Radiology, Mount Auburn Hospital, Cambridge, MA 02138 (United States); Godoy, Myrna C.B.; Groot, Patricia M. de [The University of Texas MD Anderson Cancer Center, Department of Diagnostic Radiology, Section of Thoracic Imaging, 1515 Holcombe Blvd., Unit 1478, Houston, TX 77030 (United States); Abbott, Gerald F. [Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, FND-202, Boston, MA 02114 (United States); Lichtenberger III, John P. [Department of Radiology, David Grant Medical Center, Travis AFB, CA 94535 (United States)

    2014-08-15

    Lymphoma is the most common hematologic malignancy and represents approximately 5.3% of all cancers. The World Health Organization published a revised classification scheme in 2008 that groups lymphomas by cell type and molecular, cytogenetic, and phenotypic characteristics. Most lymphomas affect the thorax at some stage during the course of the disease. Affected structures within the chest may include the lungs, mediastinum, pleura, and chest wall, and lymphomas may originate from these sites as primary malignancies or secondarily involve these structures after arising from other intrathoracic or extrathoracic sources. Pulmonary lymphomas are classified into one of four types: primary pulmonary lymphoma, secondary pulmonary lymphoma, acquired immunodeficiency syndrome-related lymphoma, and post-transplantation lymphoproliferative disorders. Although pulmonary lymphomas may produce a myriad of diverse findings within the lungs, specific individual features or combinations of features can be used, in combination with secondary manifestations of the disease such as involvement of the mediastinum, pleura, and chest wall, to narrow the differential diagnosis. While findings of thoracic lymphoma may be evident on chest radiography, computed tomography has traditionally been the imaging modality used to evaluate the disease and effectively demonstrates the extent of intrathoracic involvement and the presence and extent of extrathoracic spread. However, additional modalities such as magnetic resonance imaging of the thorax and {sup 18}F-FDG PET/CT have emerged in recent years and are complementary to CT in the evaluation of patients with lymphoma. Thoracic MRI is useful in assessing vascular, cardiac, and chest wall involvement, and PET/CT is more accurate in the overall staging of lymphoma than CT and can be used to evaluate treatment response.

  18. Lens dosimetry during examination of the sella turcica: comparison between conventional tomography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Louis, O.; Bette, L.; Noseda, A.

    1986-01-01

    Lens irradiation measurements were performed with thermo-luminescent lithium fluoride dosimeters during tomographic examinations of the sella turcica, simulated on a phantom head. Lens dosimetry during linear or hypocycloidal conventional tomography was compared with that during computed tomography (CT). Results showed that CT involved much lower radiation exposure to the lens than did conventional tomography and that the major part of the irradiation delivered by CT was related to axial scanning. Therefore, the major finding was that lens irradiation during CT of the sella can be kept at a particularly low level (< 1 m Gy/8 sections) when only coronal scanning is performed.

  19. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  20. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle Westergren;

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...... study investigates the positive (PPV) and negative predictive value (NPV) of PET-CT in stage I disease and the clinical impact of the scan results in all disease stages....

  1. Optimisation of post mortem cardiac computed tomography compared to optical coherence tomography and histopathology - Technical note

    DEFF Research Database (Denmark)

    Precht, Helle; Leth, Peter Mygind; Thygesen, Jesper

    2014-01-01

    Introduction: Coronary atherosclerosis is a leading cause of mortality. New technological developments in computed tomography (CT), including dual energy, iterative reconstructions and high definition scanning, could significantly improve the non-invasive identification of atherosclerosis plaques....... Here, a new method for optimising cardiac coronary CT with optical coherence tomography (OCT) and histopathology is presented. Materials and methods: Twenty human hearts obtained from autopsies were used. A contrast agent that solidifies after cooling was injected into the coronary arteries. CT...

  2. Shielding Calculations for Positron Emission Tomography - Computed Tomography Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Baasandorj, Khashbayar [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yang, Jeongseon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    Integrated PET-CT has been shown to be more accurate for lesion localization and characterization than PET or CT alone, and the results obtained from PET and CT separately and interpreted side by side or following software based fusion of the PET and CT datasets. At the same time, PET-CT scans can result in high patient and staff doses; therefore, careful site planning and shielding of this imaging modality have become challenging issues in the field. In Mongolia, the introduction of PET-CT facilities is currently being considered in many hospitals. Thus, additional regulatory legislation for nuclear and radiation applications is necessary, for example, in regulating licensee processes and ensuring radiation safety during the operations. This paper aims to determine appropriate PET-CT shielding designs using numerical formulas and computer code. Since presently there are no PET-CT facilities in Mongolia, contact was made with radiological staff at the Nuclear Medicine Center of the National Cancer Center of Mongolia (NCCM) to get information about facilities where the introduction of PET-CT is being considered. Well-designed facilities do not require additional shielding, which should help cut down overall costs related to PET-CT installation. According to the results of this study, building barrier thicknesses of the NCCM building is not sufficient to keep radiation dose within the limits.

  3. Evaluation of myocardial ischemia by multiple detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fabio Vieira, E-mail: rccury@me.com [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Cury, Roberto Caldeira [Hospital Samaritano, Sao Paulo, SP (Brazil)

    2015-01-15

    For years, cardiovascular diseases have been the leading cause of death worldwide, bringing on important social and economic consequences. Given this scenario, the search for a method capable of diagnosing coronary artery diseases in an early and accurate way is increasingly higher. The coronary computed tomography angiogram is already widely established for the stratification of coronary artery diseases, and, more recently, the computed tomography myocardial perfusion imaging has been providing relevant information by correlating ischemia and the coronary anatomy. The objective of this review is to describe the evaluation of myocardial ischemia by multiple detector computed tomography. This study will resort to controlled clinical trials that show the possibility of a single method to identify the atherosclerotic load, presence of coronary artery luminal narrowing and possible myocardial ischemia, by means of a fast, practical and reliable method validated by a multicenter study. (author)

  4. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  5. Invasive thymoma; Radiologic evaluation by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Choon Sik; Choe, Kyu Ok [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1985-04-15

    In 6 cases of invasive thymoma proved histologically from 1981 to 1984 in Yonsei University Medical Center, the CT findings and pattern were analysed. The results were as follows; 1. Of 6 cases, 4 were males and 2 were females. All cases were between 40-64 years and the average was 51 year old. 2. Of 6 cases, 2 female patients were associated with myasthenia gravis. 3. By the histological examination, 2 were confirmed as mixed cell type, 2 spindle cell type, 1 lymphocytic type and 1 epithelial cell type. 4. CT findings of invasive thymoma were 1) A discrete but lobulated and irregular marginated soft tissue mass in the superoanterior mediastinum replacing the normal mediastinal fat tissue. 2) Usually irregular low density areas within the mass suggesting central necrosis or calcification in 1 of 6 cases was noted. 3) Local invasiveness of the mass shown as obliteration of the normal fat plans surrounding great vessels, irregular thickening or nodular shadows of the pleura, diagphragm and pericardium and irregular and ragged tumor-lung interfaces if the tumor invade to the structures. 4) Frequent extension of tumor to middle and post. mediastinum along pericardium or mediastinal pleura with resultant extrinsic indentation and/or invasion of the hilar region. 5). Extensive tumor infiltration to middle and post. mediastinum in 1 case, indistinguishable from lymphoma. 6) Low attenuation numbered area of brain in another 1 case, but not confirmed histologically.

  6. Predictive value of initial involvement and early response assessment using positron‑emission tomography with 18F‑FLT in patients with non‑Hodgkin lymphoma

    Directory of Open Access Journals (Sweden)

    Yu. N. Likar

    2012-01-01

    Full Text Available The monitoring of treatment efficacy in patients with diffuse large B‑cell lymphoma (DLBCL is generally performed by common computed tomography (CT. However, CT cannot distinguish between a real and residual tissue mass and in addition cannot be very useful in assessment of early response. 18F‑FDG Positron‑emission tomography (PET has high prognostic implications at treatment completion but is limited as an early predictor. We present the results of a retrospective study where we have evaluated predictive value of initial and interim‑PET(I‑PET with 18F‑FLT on clinical outcome.Methods. 39 patients were evaluated retrospectively with 18F‑FLT PET before treatment and interim 18F‑FLT PET after 1 cycles of chemotherapy. PET was performed 40−60 minutes after injection of 270−340 MBq of 18F‑FLT. Maximum standardized uptake values (SUVmax  were calculated on a lesion. Response was assessed according to protocol during and in the end of therapy.Results. All lymphoma lesions identified by a reference method (18F‑FDG PET/CT or CT showed increased focal tracer uptake of 18F‑FLT. Initial mean SUVmax was significantly higher in patients who showed progressive disease and partial response (SUVmax = 9.5 ± 3.2 than inpatients who achieved complete response (SUVmax = 6.3 ± 1.6 (p = 0.018. PFS for positive and negative patients after interim 18F‑FLT PET was 85.1 % and 35.7 %, respectively (р < 0.05.Conclusion. High initial 18F‑FLT uptake is a negative treatment response predictor in patients with DLBCL. Positive I‑PET with 18F‑FLT is a negative PFS predictor compare to patients with negative I‑PET.

  7. Computed tomography of sellar and parasellar lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, Mitsunori; Aoki, Hideo (Yamaguchi Univ., Ube (Japan). School of Medicine)

    1982-06-01

    Neuroradiological modalities, particularly CT, for sellar and parasellar lesions were reviewed. Although accurate preoperative diagnosis is sometimes difficult, CT diagnosed 83% as far as pituitary adenoma, craniopharyngioma and meningioma were concerned and demonstrated abnormal findings in 95% of parasellar tumors. At the authors' department, CT visualized abnormalities in all cases, with the exception of suprasellar arachnoid cyst, but a histological diagnosis was possible only in 84%. Since lesions including tumors cannot be completely denied even if CT shows normal images, findings by modalities such as plain craniography, cerebral tomography, cerebral angiography and cisternography should be judged comprehensively.

  8. Anaesthesia for magnetic resonance imaging/computed tomography.

    Science.gov (United States)

    Funk, W; Taeger, K

    2000-08-01

    The need for general anaesthesia for magnetic resonance imaging/computed tomography investigations can be reduced by the implementation of structured sedation programmes supervised by anaesthetists. Despite its side-effects, chloral hydrate is still the drug most widely used. Rectal thiopental or intravenous propofol are suggested anaesthetic agents for pre-school children and uncooperative or claustrophobic individuals. Spiral computed tomography scans and ultrafast magnetic resonance imaging shorten immobilization times further. However, functional magnetic resonance imaging and intervention techniques in neuroradiology depend on a motionless patient. A useful strategy for testing anaesthesia equipment has been outlined.

  9. Computed tomography and magnetic resonance imaging of the pericardium.

    Science.gov (United States)

    Olson, M C; Posniak, H V; McDonald, V; Wisniewski, R; Moncada, R

    1989-07-01

    Computed tomography is an established modality for the evaluation of the pericardium. It is used to evaluate complicated pericardial effusions, pericardial thickening, calcific pericarditis, pericardial cysts, postoperative changes and primary and metastatic neoplasms of the pericardium. Magnetic resonance imaging is being used with increasing frequency in the evaluation of pericardial disease. It offers advantages over computed tomography, including a potential for tissue characterization, absence of ionizing radiation or need for intravenous contrast medium, and the ability to scan in any plane. Disadvantages include greater cost, longer examination times and the inability to identify calcification positively.

  10. Investigation of a near-infrared-ray computed tomography scanner

    Science.gov (United States)

    Sato, Eiichi; Oda, Yasuyuki; Satoi, Yuichi; Yamaguchi, Satoshi; Ishii, Tomotaka; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Watanabe, Manabu; Kusachi, Shinya

    2016-10-01

    In the near-infrared-ray computed tomography (NIR-CT) scanner, NIR rays are produced from a light-emitting diode (LED) and detected using an NIR phototransistor (PT). The wavelengths of the LED peak intensity and the PT high sensitivity in the data table are both 940 nm. The photocurrents flowing through the PTR are converted into voltages using an emitter-follower circuit, and the output voltages are sent to a personal computer through an analog-digital converter. The NIR projection curves for tomography are obtained by repeated linear scans and rotations of the object, and the scanning is conducted in both directions of its movement.

  11. Direct sagital computed tomography of the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Manzione, J.V. (Harvard Medical School, Boston, MA); Seltzer, S.E.; Katzberg, R.W.; Hammerschlag, S.B.; Chiango, B.F.

    1983-01-01

    Temporomandibular joint dysfunction is a common clinical problem that has been reported to affect 4%-28% of adults. Temporomandibular joint arthrography has shown that many of these patients have intraarticular abnormalities involving the meniscus. A noninvasive test that could demonstrate the meniscus as well as bony abnormalities of the joint would be an important advance. In an attempt to develop such a noninvasive test, we have performed direct sagittal computed tomography (CT) on cadaver temporomandibular joints and have correlated the images with anatomic sections. We are currently applying this technique clinically and report one representative example in which direct sagittal computed tomography of the temporomandibular joint accurately demonstrated an anteriorly displaced meniscus.

  12. Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography

    Institute of Scientific and Technical Information of China (English)

    Ka-Kit Wong; Arpit Gandhi; Benjamin L Viglianti; Lorraine M Fig; Domenico Rubello; Milton D Gross

    2016-01-01

    AIM: To review the benefits of single photon emission computed tomography(SPECT)/computed tomography(CT) hybrid imaging for diagnosis of various endocrine disorders.METHODS: We performed MEDLINE and Pub Med searches using the terms: "SPECT/CT"; "functional anatomic mapping"; "transmission emission tomography"; "parathyroid adenoma"; "thyroid cancer"; "neuroendocrine tumor"; "adrenal"; "pheochromocytoma"; "paraganglioma"; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts(case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology.RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the biodistribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTclabeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol(NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma.CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy from CT, translating to

  13. Industrial Computed Tomography using Proximal Algorithm

    KAUST Repository

    Zang, Guangming

    2016-04-14

    In this thesis, we present ProxiSART, a flexible proximal framework for robust 3D cone beam tomographic reconstruction based on the Simultaneous Algebraic Reconstruction Technique (SART). We derive the proximal operator for the SART algorithm and use it for minimizing the data term in a proximal algorithm. We show the flexibility of the framework by plugging in different powerful regularizers, and show its robustness in achieving better reconstruction results in the presence of noise and using fewer projections. We compare our framework to state-of-the-art methods and existing popular software tomography reconstruction packages, on both synthetic and real datasets, and show superior reconstruction quality, especially from noisy data and a small number of projections.

  14. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  15. 2-deoxy-2-(18F)fluoro-D-glucose positron emission tomography/computed tomography imaging in paediatric oncology

    Institute of Scientific and Technical Information of China (English)

    John; Freebody; Eva; A; Wegner; Monica; A; Rossleigh

    2014-01-01

    Positron emission tomography(PET) is a minimally in-vasive technique which has been well validated for the diagnosis, staging, monitoring of response to therapy, and disease surveillance of adult oncology patients. Tra-ditionally the value of PET and PET/computed tomogra-phy(CT) hybrid imaging has been less clearly defined for paediatric oncology. However recent evidence has emerged regarding the diagnostic utility of these mo-dalities, and they are becoming increasingly important tools in the evaluation and monitoring of children with known or suspected malignant disease. Important indi-cations for 2-deoxy-2-(18F)fluoro-D-glucose(FDG) PET in paediatric oncology include lymphoma, brain tumours, sarcoma, neuroblastoma, Langerhans cell histiocytosis, urogenital tumours and neurofibromatosis type Ⅰ. This article aims to review current evidence for the use of FDG PET and PET/CT in these indications. Attention will also be given to technical and logistical issues, the description of common imaging pitfalls, and dosimetric concerns as they relate to paediatric oncology.

  16. 3D artefact for concurrent scale calibration in Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2016-01-01

    A novel artefact for calibration of the scale in 3D X-ray Computed Tomography (CT) is presented. The artefact comprises a carbon fibre tubular structure on which a number of reference ruby spheres are glued. The artefact is positioned and scanned together with the workpiece inside the CT scanner ...

  17. Computer tomography in Caisson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, F.; Csobaly, S.

    1981-07-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts.

  18. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    subject number. The principal investigator collated all data collection sheets and organized them into a spreadsheet for final analysis. Data...available cone-beam computed tomography machine . Am J 01ihod Dentofacial Orthop 2008; 134:573-82. 7. Moshfeghi M, Tavakoli MA, Hosseini ET, et al

  19. Geometrical metrology on silicone rubber by computed tomography

    DEFF Research Database (Denmark)

    Müller, Pavel; Pacurar, Ramona Alexandra; De Chiffre, Leonardo

    2011-01-01

    Computed tomography (CT) represents a suitable measuring technique for investigation of deformable materials, since no forces are developed on the part during scanning. As for any other measuring instruments, the traceability of the CT scanners needs to be assured. An investigation on geometrical...

  20. Traceability investigation in Computed Tomography using industry-inspired workpieces

    DEFF Research Database (Denmark)

    Kraemer, Alexandra; Stolfi, Alessandro; Schneider, Timm

    2017-01-01

    This paper concerns an investigation of the accuracy of Computed Tomography (CT) measurements using four industry-inspired workpieces. A total of 16 measurands were selected and calibrated using CMMs. CT measurements on industry-inspired workpieces were carried out using two CTs having different...

  1. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    LENUS (Irish Health Repository)

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  2. Computed Tomography Features of Spontaneously Perforated Pyometra: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.S.; Tan, C.K.; Mak, C.W.; Chia, C.C.; Kuo, C.Y.; Yu, W.L. [Chi-Mei Medical Center, Tainan, Taiwan (China). Depts. of Intensive Care Medicine, Radiology, Obstetrics and Gynecology, and Surgery

    2006-03-15

    Spontaneous perforation of pyometra is an extremely rare emergent gynecologic disease. We report a 73-year-old woman with a spontaneously perforated pyometra presenting with acute abdomen in the emergency department. A dedicated computed tomography examination of the abdominal and pelvic regions revealed the diagnosis. The patient recovered well after surgical intervention and antibiotic treatment.

  3. Fractional flow reserve derived from coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Eftekhari, Ashkan; Min, James; Achenbach, Stephan

    2016-01-01

    AIMS: Fractional flow reserve (FFR) derived from coronary computed tomography (FFRCT) has high diagnostic performance in stable coronary artery disease (CAD). The diagnostic performance of FFRCT in patients with hypertension (HTN) and diabetes (DM), who are at risk of microvascular impairment, is...

  4. Computed tomography of the human developing anterior skull base

    NARCIS (Netherlands)

    J. van Loosen (J.); A.I.J. Klooswijk (A. I J); D. van Velzen (D.); C.D.A. Verwoerd (Carel)

    1990-01-01

    markdownabstractAbstract The ossification of the anterior skull base, especially the lamina cribrosa, has been studied by computed tomography and histopathology. Sixteen human fetuses, (referred to our laboratory for pathological examination after spontaneous abortion between 18 and 32 weeks of ge

  5. COMPUTED TOMOGRAPHY IN HYDATID CYST OF THE ORBIT

    Directory of Open Access Journals (Sweden)

    K. Abbassioun

    1982-07-01

    Full Text Available Two cases of hydatid cysts of the orbit causing unilateral exophthalmos are reported. Diagnosis were suspected by means of computed tomography (CT and confirmed at Operation. CT changes are described and its value in diagnosis of this lesion particularly in the endemic areas is stressed.

  6. Operator radiation exposure in cone-beam computed tomography guidance

    NARCIS (Netherlands)

    Braak, S.J.; Strijen Van, M. J L; Meijer, E.; Heesewijk Van, J. P M; Mali, W. P T M

    2016-01-01

    Objectives: Quantitative analysis of operator dose in cone-beam computed tomography guidance (CBCT-guidance) and the effect of protective shielding. Methods: Using a Rando phantom, a model was set-up to measure radiation dose for the operator hand, thyroid and gonad region. The effect of sterile rad

  7. Use of Computed Tomography Scans for Cochlear Implants

    OpenAIRE

    Whiting, Bruce R.; Holden, Timothy A.; Brunsden, Barry S.; Finley, Charles C.; Skinner, Margaret W.

    2007-01-01

    While 3-dimensional (3D) imaging by computed tomography has long been desirable for research and treatment of cochlear-implant patients, technical challenges have limited its wide application. Recent developments in scanner hardware and image processing techniques now allow image quality improvements that make clinical applications feasible. Validation experiments were performed to characterize a new methodology and its imaging performance.

  8. Computed tomography diagnosis of partial anomalous pulmonary venous drainage.

    Science.gov (United States)

    Posniak, H V; Dudiak, C M; Olson, M C

    1993-01-01

    A case of the rarely occurring partial anomalous pulmonary venous drainage of the right upper lobe into the azygos arch is presented. Computed tomography (CT) clearly demonstrated the abnormal vessel coursing through the right upper lobe and draining into the azygos arch.

  9. Coronary computed tomography - present status and future directions

    NARCIS (Netherlands)

    Apfaltrer, P.; Schoepf, U. J.; Vliegenthart, R.; Rowe, G. W.; Spears, J. R.; Fink, C.; Nance, J. W.

    2011-01-01

    The use of coronary computed tomography angiography (cCTA) is growing rapidly, in large part because of fast-paced technical innovations that have increased diagnostic accuracy while providing new opportunities for radiation dose reduction. cCTA using recent generation CT scanners has been repeatedl

  10. Coronary artery fly-through using electron beam computed tomography

    NARCIS (Netherlands)

    van Ooijen, P M; Oudkerk, M; van Geuns, R J; Rensing, B J; de Feyter, P J

    2000-01-01

    BACKGROUND: Virtual reality techniques have recently been introduced into clinical medicine. This study examines the possibility of coronary artery fly-through using a dataset obtained by noninvasive coronary angiography with contrast-enhanced electron-beam computed tomography. METHODS AND RESULTS:

  11. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer...

  12. Tolerance Verification of an Industrial Assembly using Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo; Regi, Francesco

    2016-01-01

    This paper reports on results of tolerance verification of a multi-material assembly by using Computed Tomography (CT). The workpiece comprises three parts which are made out of different materials. Five different measurands were inspected. The calculation of measurement uncertainties was attempt...

  13. Global seismic tomography and modern parallel computers

    Directory of Open Access Journals (Sweden)

    A. Piersanti

    2006-06-01

    Full Text Available A fast technological progress is providing seismic tomographers with computers of rapidly increasing speed and RAM, that are not always properly taken advantage of. Large computers with both shared-memory and distributedmemory architectures have made it possible to approach the tomographic inverse problem more accurately. For example, resolution can be quantified from the resolution matrix rather than checkerboard tests; the covariance matrix can be calculated to evaluate the propagation of errors from data to model parameters; the L-curve method can be applied to determine a range of acceptable regularization schemes. We show how these exercises can be implemented efficiently on different hardware architectures.

  14. Omitting radiotherapy in early positron emission tomography-negative stage I/II Hodgkin lymphoma is associated with an increased risk of early relapse

    DEFF Research Database (Denmark)

    Raemaekers, John M M; André, Marc P E; Federico, Massimo

    2014-01-01

    PURPOSE: Combined-modality treatment is standard treatment for patients with clinical stage I/II Hodgkin lymphoma (HL). We hypothesized that an early positron emission tomography (PET) scan could be used to adapt treatment. Therefore, we started the randomized EORTC/LYSA/FIL Intergroup H10 trial ...

  15. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science, Tec...

  16. Comparison of Computed Tomography Scout Based Reference Point Localization to Conventional Film and Axial Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C.H., E-mail: jchu@rush.edu

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  17. Cranial computed tomography in psychiatry. Kraniale Computertomographie in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Falkai, P. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany)); Bogerts, B. (Rheinische Landes- und Hochschulklinik Duesseldorf, Psychiatrische Klinik der Heinrich-Heine-Universitaet (Germany))

    1993-08-13

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.)

  18. Assessment of asthmatic inflammation using hybrid fluorescence molecular tomography-x-ray computed tomography

    Science.gov (United States)

    Ma, Xiaopeng; Prakash, Jaya; Ruscitti, Francesca; Glasl, Sarah; Stellari, Fabio Franco; Villetti, Gino; Ntziachristos, Vasilis

    2016-01-01

    Nuclear imaging plays a critical role in asthma research but is limited in its readings of biology due to the short-lived signals of radio-isotopes. We employed hybrid fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) for the assessment of asthmatic inflammation based on resolving cathepsin activity and matrix metalloproteinase activity in dust mite, ragweed, and Aspergillus species-challenged mice. The reconstructed multimodal fluorescence distribution showed good correspondence with ex vivo cryosection images and histological images, confirming FMT-XCT as an interesting alternative for asthma research.

  19. X-ray computed tomography of PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Pfrang, Andreas; Veyret, Damien; Tsotridis, Georgios [Commission of the European Communities, Petten (Netherlands). Joint Reseach Centre, Inst. for Energy; Janssen, Gaby [Energy Research Centre of the Netherlands ECN, Petten (Netherlands). Dept. of Hydrogen and Clean Fossil Fuels

    2010-07-01

    Proton exchange membrane (PEM) fuel cells were investigated by 3D x-ray computed tomography at a voxel size of 0.7 {mu}m. It is shown that this lab-based technique is not only suitable for the investigation of gas diffusion layers (GDL) as well as the investigation of membrane electrode assemblies (MEA), but also allows the calculation of macroscopic physical properties. The resolution of computed tomography is clearly sufficient to image the carbon fiber structure of gas diffusion layers in the as received GDLs as well as GDLs integrated into membrane electrode assemblies. It is also possible to visualize the catalyst layer within the MEA, which allows the investigation of layer thickness and structural defects on a larger scale than with conventional techniques. The macroscopic effective thermal conductivities of the gas diffusion layers were computed based on the 3D GDL structure reconstructed from tomography data to produce more reliable input data for fuel cell modeling. The computation was carried out by solving the energy equation considering a pure thermal conduction problem. The computations show - in agreement with the expectation and experimental data - that the through-plane thermal conductivities are lower than the in-plane thermal conductivities. (orig.)

  20. Coordinate Metrology by Traceable Computed Tomography

    DEFF Research Database (Denmark)

    Müller, Pavel

    metrology and coordinate metrology and is currently becoming more and more important measuring technique for dimensional measurements. This is mainly due to the fact that with CT, a complete three-dimensional model of the scanned part is in a relatively short time visualized using a computer...... is an important factor for decision making about manufactured parts. However, due to many influences in CT, estimation of the uncertainty is a challenge, also because standardized procedures and guidelines are not available yet. In this thesis, several methods for uncertainty estimation were applied in connection...

  1. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  2. The predictive role of interim positron emission tomography for Hodgkin lymphoma treatment outcome is confirmed using the interpretation criteria of the Deauville five-point scale

    DEFF Research Database (Denmark)

    Gallamini, Andrea; Barrington, Sally F; Biggi, Alberto

    2014-01-01

    A retrospective, international, multicenter study was undertaken to assess: (i) the prognostic role of 'interim' positron emission tomography performed during treatment with doxorubicin, bleomycin, vinblastine and dacarbazine in patients with Hodgkin lymphoma; and (ii) the reproducibility...... of the Deauville five-point scale for the interpretation of interim positron emission tomography scan. Two hundred and sixty patients with newly diagnosed Hodgkin lymphoma were enrolled. Fifty-three patients with early unfavorable and 207 with advanced-stage disease were treated with doxorubicin, bleomycin......, vinblastine and dacarbazine ± involved-field or consolidation radiotherapy. Positron emission tomography scan was performed at baseline and after two cycles of chemotherapy. Treatment was not changed according to the results of the interim scan. An international panel of six expert reviewers independently...

  3. Computed tomography of the acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ho Young; Suh, Jin Suck; Park, Chang Yun; Lee, Kil Woo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-04-15

    In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.

  4. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  5. Computed tomography of human joints and radioactive waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, E; Bernardi, R; Hollerbach, K; Logan, C; Martz, H; Roberson, G P

    1999-06-01

    X- and gamma-ray imaging techniques in nondestructive evaluation (NDE) and assay (NDA) have been increasing use in an array of industrial, environmental, military, and medical applications. Much of this growth in recent years is attributed to the rapid development of computed tomography (CT) and the use of NDE throughout the life-cycle of a product. Two diverse examples of CT are discussed. (1) The computational approach to normal joint kinematics and prosthetic joint analysis offers an opportunity to evaluate and improve prosthetic human joint replacements before they are manufactured or surgically implanted. Computed tomography data from scanned joints are segmented, resulting in the identification of bone and other tissues of interest, with emphasis on the articular surfaces. (2) They are developing NDE and NDE techniques to analyze closed waste drums accurately and quantitatively. Active and passive computed tomography (A and PCT) is a comprehensive and accurate gamma-ray NDA method that can identify all detectable radioisotopes present in a container and measure their radioactivity.

  6. Initial water quantification results using neutron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.K. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)], E-mail: axh174@psu.edu; Shi, L.; Brenizer, J.S.; Mench, M.M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University (United States)

    2009-06-21

    Neutron computed tomography is an important imaging tool in the field of non-destructive testing and in fundamental research for many engineering applications. Contrary to X-rays, neutrons can be attenuated by some light materials, such as hydrogen, but can penetrate many heavy materials. Thus, neutron computed tomography is useful in obtaining important three-dimensional information about a sample's interior structure and material properties that other traditional methods cannot provide. The neutron computed tomography system at Pennsylvania State University's Radiation Science and Engineering Center is being utilized to develop a water quantification technique for investigation of water distribution in fuel cells under normal conditions. A hollow aluminum cylinder test sample filled with a known volume of water was constructed for purposes of testing the quantification technique. Transmission images of the test sample at different angles were easily acquired through the synthesis of a dedicated image acquisition computer driving a rotary table controller and an in-house developed synchronization software package. After data acquisition, Octopus (version 8.2) and VGStudio Max (version 1.2) were used to perform cross-sectional and three-dimensional reconstructions of the sample, respectively. The initial reconstructions and water quantification results are presented.

  7. Brain computed tomography of the hypertensive patients

    Energy Technology Data Exchange (ETDEWEB)

    Bae, W. K.; Park, C. K.; Cho, O. K.; Hahm, C. K. [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1980-12-15

    Now a day, hypertension is more increasing in frequency and ranked the top of the causes of death in Korea and other nations. Most of cerebrovascular accidents in hypertensive patients are composed of vascular occlusive changes and hemorrhages. In cerebral angiogram, we can only detect occlusion of large artery and large mass effect from hematoma or cerebral infarction without identification of its entity. The computed tomogram, however, is the best way for evaluation of cerebrovascular diseases including detection of nature, location, amount, and associated changes. This study includes evaluation of computed tomograms of 106 patients with hypertension during the period of 17 months from Feb. 1979 to June 1980 in the department of radiology, college of Medicine, Hanyang University. The results were as follows. 1. Age distribution of the total 106 patients was broad ranging from 25 years to 76 years. 67.9% of patients were over the age of 50. The male and female sex ratio was 3:2. 2. 28 out of 106 patients were normal and 78 patients revealed abnormal on C. T. findings; those were intracranial hemorrhage (35 patients), cerebral infarction (32 patients) and brain atrophy (11 patients). 3. All of the intracranial hemorrhage except one were intracerebral hemorrhage; those were located in the cerebral hemisphere (19 patients), basal ganglia (15 patients) and brain stem (1 patient). The except one case of intracranial hemorrhage was subdural hematoma. 7 patients of intraventricular hemorrhage and 1 patient of subarachnoid hemorrhage were combined with intracerebral hemorrhage. 2/3 of patients who had hemorrhage in cerebral hemisphere revealed lesions in the parietal and temporal lobes. 4. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (20 cases), and the next was basal ganglia (11 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. The left basal ganglia was more commonly involved

  8. Computed Tomography of the Normal Bovine Tarsus.

    Science.gov (United States)

    Hagag, U; Tawfiek, M; Brehm, W; Gerlach, K

    2016-12-01

    The objective of this study was to provide a detailed multiplanar computed tomographic (CT) anatomic reference for the bovine tarsus. The tarsal regions from twelve healthy adult cow cadavers were scanned in both soft and bone windows via a 16-slice multidetector CT scanner. Tarsi were frozen at -20(o) C and sectioned to 10-mm-thick slices in transverse, dorsal and sagittal planes respecting the imaging protocol. The frozen sections were cleaned and then photographed. Anatomic structures were identified, labelled and compared with the corresponding CT images. The sagittal plane was indispensable for evaluation of bone contours, the dorsal plane was valuable in examination of the collateral ligaments, and both were beneficial for assessment of the tarsal joint articulations. CT images allowed excellent delineation between the cortex and medulla of bones, and the trabecular structure was clearly depicted. The tarsal soft tissues showed variable shades of grey, and the synovial fluid was the lowest attenuated structure. This study provided full assessment of the clinically relevant anatomic structures of the bovine tarsal joint. This technique may be of value when results from other diagnostic imaging techniques are indecisive. Images presented in this study should serve as a basic CT reference and assist in the interpretation of various bovine tarsal pathology. © 2016 Blackwell Verlag GmbH.

  9. Role of computed tomography in pancreatic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Kim, Ki Whang; Lee, Jong Tae; Oh, Sei Jung [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1991-03-15

    At Yonsei University Hospital from January 1984 to August 1990, computed tomographic (CT) scans of 13 patients with surgically proven pancreatic injuries after blunt abdominal trauma, including 6 pancreatic lacerations or contusions, 6 pancreatic fractures, and one post-traumatic pseudocyst, were retrospectively reviewed to determine the role and accuracy of the CT in evaluating pancreatic injury. CT can document gross pancreatic injury by showing focal or diffuse enlargement (1), area of diminished attenuation (3), separation (5), focal hematoma (2), and peripancreatic change, including peripancreatic hematoma (2), fluid collection (11), perirenal fascial thickening (10), omental and mesenteric change (5), and bowel change (2). CT correctly diagnosed pancreatic fracture in 5 cases, post-raumatic pseudocyst in 1 case, and pancreatic laceration in 3 cases in 9 of these patients. There were 4 false negative diagnoses, including 3 pancreatic lacerations and 1 pancreatic fracture. A CT is of pancreatic trauma could be difficult to diagnosis in patients who are scanned within 24 hrs after an injury or to distinguish a motion or streak artifact caused by a nasogastric tube or air-oral contrast fluid level in the stomach.

  10. Minimal Residual Disease Assessment in Lymphoma: Methods and Applications.

    Science.gov (United States)

    Herrera, Alex F; Armand, Philippe

    2017-09-21

    Standard methods for disease response assessment in patients with lymphoma, including positron emission tomography and computed tomography scans, are imperfect. In other hematologic malignancies, particularly leukemias, the ability to detect minimal residual disease (MRD) is increasingly influencing treatment paradigms. However, in many subtypes of lymphoma, the application of MRD assessment techniques, like flow cytometry or polymerase chain reaction-based methods, has been challenging because of the absence of readily detected circulating disease or canonic chromosomal translocations. Newer MRD detection methods that use next-generation sequencing have yielded promising results in a number of lymphoma subtypes, fueling the hope that MRD detection may soon be applicable in clinical practice for most patients with lymphoma. MRD assessment can provide real-time information about tumor burden and response to therapy, noninvasive genomic profiling, and monitoring of clonal dynamics, allowing for many possible applications that could significantly affect the care of patients with lymphoma. Further validation of MRD assessment methods, including the incorporation of MRD assessment into clinical trials in patients with lymphoma, will be critical to determine how best to deploy MRD testing in routine practice and whether MRD assessment can ultimately bring us closer to the goal of personalized lymphoma care. In this review article, we describe the methods available for detecting MRD in patients with lymphoma and their relative advantages and disadvantages. We discuss preliminary results supporting the potential applications for MRD testing in the care of patients with lymphoma and strategies for including MRD assessment in lymphoma clinical trials.

  11. The pleural sandwich sign in two cases of primary pleural lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoo Kyung; Lee, Myung Jae; Ryu, Yon Ju; Cho, Min Sun [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2015-02-15

    The sandwich sign is used to describe mesenteric lymphoma in which mesenteric vessels and fat are enveloped by enlarged mesenteric lymph nodes. We present two cases of primary pleural lymphoma demonstrating the 'pleural sandwich sign'. Contrast-enhanced computed tomography showed conglomerated parietal pleural and extrapleural masses encasing the intercostal arteries. Histopathological examinations confirmed low grade marginal zone B-cell lymphoma in an 80-year-old man and diffuse large B-cell lymphoma in a 68-year-old man. The pleural sandwich sign may suggest the diagnosis of primary pleural lymphoma.

  12. High Resolution Muon Computed Tomography at Neutrino Beam Facilities

    CERN Document Server

    Suerfu, Burkhant

    2015-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pio...

  13. Didactics and training in cardiovascular computed tomography angiography.

    Science.gov (United States)

    Bhojraj, Sanjay D; Al-Mallah, Mouaz H

    2009-01-01

    As the role of cardiovascular computed tomography angiography (CCTA) is further expanded through research, the use of this technology will expand as a result of demand both from medical professionals and the public. To ensure a standardized quality of interpretation of these scans in the face of an increased demand for physicians qualified to interpret these studies, the Society of Cardiovascular Computed Tomography, along with several other professional societies, has proposed a didactic curriculum for the study of CCTA. This review highlights the currently proposed didactic curriculum for the study of CCTA, examines current trends in training for both medical trainees and physicians in practice, and proposes future directions for the study of CCTA.

  14. Project of evaluation of doses in computed tomography in Poland

    Energy Technology Data Exchange (ETDEWEB)

    Slusarczyk-Kacprzyk, W.; Skrzynski, W.; Bulski, W. [Centre of Oncology, Medical Physics Dept., Warsaw (Poland)

    2006-07-01

    Project of evaluation of doses in computed tomography in Poland bases on the organization solutions implemented and evaluated at one of Polish oncological centres. In this study we analyzed doses for a group of 484 patients who underwent an examination with a G.E. HiSpeed CT scanner at the Centre of Oncology in Warsaw. Patient doses (weighted computed tomography dose index, C.T.D.I.w. and dose length product, D.L.P.) have been compared against reference values published by the Polish Ministry of Health. We found that typical patient doses do not exceed reference values. As reference dose levels are defined only for a standard-size patients, sometimes they may be exceeded for a properly done examination. Polish reference dose levels are not based on up-to-date data and should be revised. (authors)

  15. Mandibular condyle position in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Hyoung Joo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Kyung Hee Univ. School of Dentistry, Seoul (Korea, Republic of)

    2006-06-15

    To evaluate position of the mandibular condyle within articular fossa in an asymptomatic population radiographically by a cone beam computed tomography. Cone beam computed tomography of 60 temporomandibular joints was performed on 15 males and 15 females with no history of any temporomandibular disorders, or any other orthodontic or photoconductors treatments. Position of mandibular condyle within articular fossa at centric occlusion was evaluated. A statistical evaluation was done using a SPSS. In the sagittal views, mandibular condyle within articular fossa was laterally located at central section. Mandibular condyles in the right and left sides were showed asymmetric positional relationship at medial, central, and lateral sections. Mandibular condyle within articular fossa in an asymptomatic population was observed non-concentric position in the sagittal and coronal views.

  16. Usefulness of F-18 FDG PET/CT in subcutaneous panniculitis-like T cell lymphoma: disease extent and treatment response evaluation

    OpenAIRE

    Kim, Jin-Suk; Jeong, Young Jin; Sohn, Myung-Hee; Jeong, Hwan-Jeong; Lim, Seok Tae; KIM, Dong Wook; Kwak, Jae-Yong; Yim, Chang-Yeol

    2012-01-01

    Background. Subcutaneous panniculitis-like T-cell lymphoma (SPTCL) is a rare form of cutaneous lymphomas, accounting for less than 1% of cases of non-Hodgkin’s lymphoma. Fluorine-18 fluorodeoxyglucose (F-18 FDG) positron-emission tomography/computed tomography (PET/CT) findings of SPTCL before and after treatment were rarely reported. Case report. We report a case of SPTCL in which F-18 FDG PET/CT showed increased FDG accumulations in numerous subcutaneous nodules without extracutaneous disea...

  17. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    OpenAIRE

    Augusto Castelli von Atzingen; Dario Ariel Tiferes; Carlos Alberto Matsumoto; Thiago Franchi Nunes; Marcos Vinicius Alvim Soares Maia; Giuseppe D'Ippolito

    2012-01-01

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensiona...

  18. Moulding process characterization of paper bottles using computed tomography

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano

    2016-01-01

    The paper presents an approach of evaluating the moulding process for production of paper bottlesusing Computed Tomography (CT). Moulded Pulp Products (MPP) are made of a formed, dewateredand dried mixture of pulp fibers and water. Modern industrial pulp moulding is datedback to the year 1903 when...... a patent for MPP production was acquired by Martin L. Keyes1. Withan increasing demand for environmental friendly products, researchers are now focusing on investigatingadvance manufacturing process for production of MPP2....

  19. Computed tomography-based subclassification of chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Dirksen, Asger; Wille, Mathilde M W

    2016-01-01

    Computed tomography (CT) is an obvious modality for subclassification of COPD. Traditionally, the pulmonary involvement of chronic obstructive pulmonary disease (COPD) in smokers is understood as a combination of deleterious effects of smoking on small airways (chronic bronchitis and small airways...... observed in COPD are subtle. Furthermore, recent results indicate that emphysema may also be the essential pathophysiologic mechanism behind the airflow limitation of COPD. The definition of COPD excludes bronchiectasis as a symptomatic subtype of COPD, and CT findings in chronic bronchitis...

  20. Computed tomography changes following cryotherapy for hepatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    King, J.; Morris, D. L. [University of NSW, Sydney (Australia). Department of Surgery; Glenn, D. [St George Hospital, Kogarah, Sydney (Australia). Department of Radiology

    1997-05-01

    Encouraging survival and tumour marker results have been described in patients where the focally destructive technique, hepatic cryotherapy, is used to treat primary and secondary hepatic malignancy. Radiology allows assessment of the cryotherapy procedure and follow-up treatment. This paper aims to review and describe the appearance of hepatic cryotherapy by computed tomography which allows assessment of the adequacy of surgical technique and offers the ability to identify recurrences that may be suitable for further treatment. 11 refs., 1 tab., 9 figs.

  1. Predicting Neck Abscess with Contrast-Enhanced Computed Tomography

    OpenAIRE

    2014-01-01

    Neck abscesses are difficult to diagnose and treat. Currently, contrast-enhanced computed tomography (CECT) is the imaging modality of choice. The study aims to determine the predictive value of CECT findings in diagnosing neck abscess, causes of neck abscess and the most common neck space involved in the local population. 84 consecutive patients clinically suspected to have neck abscess who underwent CECT and surgical confirmation of pus were included. Demographic and clinical data were reco...

  2. Use of Cone Beam Computed Tomography in Endodontics

    Science.gov (United States)

    Scarfe, William C.; Levin, Martin D.; Gane, David; Farman, Allan G.

    2009-01-01

    Cone Beam Computed Tomography (CBCT) is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D) representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imaging adjunct for endodontics. PMID:20379362

  3. The role of computed tomography in modern paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Maudgil, D.D.; McHugh, K. E-mail: kmchugh@gosh.nhs.uk

    2002-08-01

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study.

  4. Contraindications to lumbar puncture as defined by computed cranial tomography.

    OpenAIRE

    Gower, D. J.; Baker, A. L.; Bell, W O; Ball, M R

    1987-01-01

    Papilloedema is not always an adequate predictor of potential complications from lumbar puncture, and many clinicians are using computed tomography (CT) before lumbar puncture in an effort to identify more accurately the "at risk" patient. This paper identifies the following anatomical criteria defined by CT scanning that correlate with unequal pressures between intracranial compartments and predispose a patient to herniation following decompression of the spinal compartment: lateral shift of...

  5. Computed tomography angiography in the investigation of carotid stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, A.J.P.; Mendelow, A.D.; Birchall, D

    2001-07-01

    The assessment of carotid atherosclerotic disease is an essential pre-requisite for determining a patients suitability for carotid endarterectomy to prevent ischaemic stroke. Catheter angiography is regarded as the most accurate investigative tool for this purpose. However, with its finite morbidity and invasiveness, there is an increasing reliance upon non-invasive methods to accurately assess carotid disease. We present a review of the technique and applications of computed tomography angiography. Goddard, A.J. P.et al. (2001)

  6. Ureterolithiasis: classical and atypical findings on unenhanced helical computed tomography.

    Science.gov (United States)

    Vaswani, Kuldeep K; El-Dieb, Adam; Vitellas, Kenneth M; Bennett, William F; Bova, James G

    2002-03-01

    Evaluation of patients with acute flank pain using helical computed tomography (CT) is a well-accepted, rapid, and safe procedure in the emergency setting. Various primary and secondary signs are described in the literature for evaluation of these patients. Our purpose is to demonstrate both the classical findings associated with ureteral calculi on unenhanced helical CT and atypical findings and potential pitfalls. We also provide readers with a systematic approach to interpreting unenhanced helical CT scans performed for acute flank pain.

  7. Use of Cone Beam Computed Tomography in Endodontics

    OpenAIRE

    Scarfe, William C.; Martin D. Levin; David Gane; Farman, Allan G.

    2009-01-01

    Cone Beam Computed Tomography (CBCT) is a diagnostic imaging modality that provides high-quality, accurate three-dimensional (3D) representations of the osseous elements of the maxillofacial skeleton. CBCT systems are available that provide small field of view images at low dose with sufficient spatial resolution for applications in endodontic diagnosis, treatment guidance, and posttreatment evaluation. This article provides a literature review and pictorial demonstration of CBCT as an imagin...

  8. Hypoplasia of the parotid gland: computed tomography sialography diagnosis.

    Science.gov (United States)

    Sun, Lisha; Sun, Zhipeng; Ma, Xuchen

    2013-10-01

    We report two unusual cases of non-syndromic hypoplasia of the parotid gland. The hypoplastic parotid gland mimicked a preauricular parotid tumor in one case and presented as an incidental image finding in the other case. Absence of the deep lobe and isthmus of the parotid parenchyma could be determined on axial computed tomography (CT) by revealing fat tissue composition of the parotid space. The underdeveloped superficial lobe of the gland was observed on three-dimensional CT sialography.

  9. Computed tomography of common congenital lesions of the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Yuen, H.Y. E-mail: drhyyuen@doctors.org.uk; Ahuja, A.T.; Wong, K.T.; Yue, V.; Hasselt, A.C. van

    2003-09-01

    This pictorial review describes the application of high-resolution computed tomography to the investigation and pre-operative work-up of the common lesions of congenital hearing loss, including congenital aural dysplasia, various congenital ossicular anomalies, inner ear dysmorphology, large vestibular aqueduct syndrome, and congenital absence of cochlear nerve and labyrinthitis ossificans from previous infection. The aim is to help radiologists to provide a more accurate diagnosis of underlying aetiology and assist in surgical planning.

  10. Computed tomography of partial unilateral agenesis of the pectoralis muscles.

    Science.gov (United States)

    Demos, T C; Johnson, C; Love, L; Posniak, H

    1985-01-01

    The most common congenitally absent muscles are the pectoralis major and minor. Absence is usually incomplete. This anomaly is often one component of a syndrome associated with other hand (Poland syndrome) and thoracic anomalies. Computed tomography can identify partial absence of the pectoralis muscle and exactly define the altered anatomy. A patient with myasthenia gravis and isolated partial agenesis of the pectoralis muscle is presented.

  11. Analysis of Multilayered Printed Circuit Boards using Computed Tomography

    Science.gov (United States)

    2014-05-01

    resistors harder to identify as Carbon is lower in the periodic table than Aluminium Oxide . Sample 2: Colour Bar Appendix D.2...Aluminium Al2O3 Aluminium Oxide BGA Ball Grid Array Coronal XZ Plane COTS Commercial Off The Shelf C Carbon CT Computed Tomography DC Direct Current...encapsulated in steel housing. Red Circle: Thin film resistors harder to identify as Carbon is lower in the periodic table than Aluminium Oxide . Sample 2

  12. Soil Macropore Structure Characterized by X-Ray Computed Tomography

    Institute of Scientific and Technical Information of China (English)

    FENG Jie; ZHANG Jia-Bao; ZHU An-Ning; BI Jing-Wei

    2003-01-01

    Undisturbed soil core with many macropores and disturbed soil core with only one macropore (diameter is 10 mm) were probed by x-ray computed tomography (CT). The size, number, shape and continuity of macropores in the transverse and vertical sections of soil were characterized using CT scanning images. The probability densities of macropores in the transverse section of soil core exhibited a logarithmic Γ distribution.Results indicated that CT scanning was a promising nondestructive method for characterizing macropores in soils.

  13. Role of computed tomography in the study of vascular pathology

    Energy Technology Data Exchange (ETDEWEB)

    Procacci, C.; Bicego, E.; Bergamo, I.A. and others

    1988-01-01

    The most important indications to the use of computed tomography (CT) in the study of vascular pathology are considered. They may be divided as follows: 1) demonstration of vascular involvement by thoraco-abdominal neoplasms; 2) differential diagnosis between primary vascular and extra-vascular pathology; 3) assessment of primary arterial pathology. For each group, those pathologies are considered, for which CT plays a fundamental role.

  14. Computed tomography of the pathological temporal bone. Malformations. Otospongiosis

    Energy Technology Data Exchange (ETDEWEB)

    Azais, O.; Drouineau, J.; Vandermarcq, P.; Barret, D.; Gasquet, C.

    1988-01-01

    The authors evaluate the value of computed tomography in the investigation of malformations and otospongiosis of the ear. Although the CT scan appears to be essential in the preoperative of malformations of the ear, especially as otological examination frequently contributes little to the evaluation of the middle ear, otospongiosis seems to be a less formal indication, except in the predominantly cochlear forms of the disease.

  15. Computed tomography in patients with Ehlers-Danlos syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hagino, Hiroshi; Sugitani, Akitoshi; Eda, Isematsu; Takashima, Sachio; Takeshita, Kenzo

    1985-09-01

    Three patients with Ehlers-Danlos syndrome were reported. Unusual findings on computed tomography were seen in two of the three patients. One case showed peculiar and marked dilatation of the 4th ventricle, supracerebellar cistern and lateral ventricle. The other case presented disproportionate enlargement of the anterior horn of the lateral ventricle. These CT findings in the two patients suggest that developmental abnormalities may constitute a structural defect.

  16. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)

  17. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  18. Helical computed tomography in the assessment of abdominal aortic pathology

    Energy Technology Data Exchange (ETDEWEB)

    Vicaretti, M.; Young, N.; Jenkins, J.; Fletcher, J. [Westmead Hospital, Westmead, NSW (Australia)

    1997-05-01

    A pilot study was undertaken to evaluate the role of helical computed tomography in the assessment of abdominal aortic pathology. A total of 17 patients underwent intra-arterial digital subtraction angiography (IADSA) and helical computed tomography, with eight patients undergoing subsequent operative intervention. A comparison of radiological findings between IADSA and helical computed tomography (CT) was made and, where applicable, a comparison was made with operative findings. Pathology included abdominal aortic aneurysm (AAA) (n=12), thoraco abdominal aneurysm (n=2) and dissection (n=1), graft distension following AAA repair (n=1) and plaque haemorrhage in the distal aorta following percutaneous transluminal angioplasty (PTA) of the iliac artery (n=1). Planned operative management as based on pre-operative helical CT imaging findings, in particular with reference to the type of graft used (straight or bifurcated) was not changed at operation. Our findings on helical CT in regards to AAA, thoraco-abdominal aneurysm and dissection correlated well with angiography and surgery findings. (authors). 26 refs., 2 tabs., 5 figs.

  19. Efficacy of multislice computed tomography for gastroenteric and hepatic surgeries

    Institute of Scientific and Technical Information of China (English)

    Hiroshi Ohtani; Mitsuo Tsubakimoto; Hidemi Kawajiri; Yuichi Arimoto; Koichi Ohno; Yasuhisa Fujimoto; Hiroko Oba; Kenji Adachi; Masaya Hirano; Shoichi Terakawa

    2005-01-01

    AIM: To determine the efficacy of multislice CT for gastroenteric and hepatic surgery.METHODS: Dual-phase helical computed tomography was performed in 50 of 51 patients who underwent gastroenteric and hepatic surgeries. Twenty-eight, eighteen and four patients suffering from colorectal cancer, gastric cancer,and liver cancer respectively underwent colorectal surgery (laparoscopic surgery: 6 cases), gastrectomy, and hepatectomy. Three-dimensional computed tomography imaging of the inferior mesenteric artery, celiac artery and hepatic artery was performed. And in the follow-up examination of postoperative patients, multiplanar reconstruction image was made in case of need.RESULTS: Scans in 50 patients were technically satisfactory and included in the analysis. Depiction of major visceral arteries, which were important for surgery and other treatments, could be done in all patients.Preoperative visualization of the left colic artery and sigmoidal arteries, the celiac artery and its branches, and hepatic artery was very useful to lymph node dissection,the planning of a reservoir and hepatectomy. And multiplanar reconstruction image was helpful to diagnosis for the postoperative follow-up of patients.CONCLUSION: Three-dimensional volume rendering or multiplanar reconstruction imaging performed by multislice computed tomography was very useful for gastroenteric and hepatic surgeries.

  20. Anatomical structure of lingual foramen in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Min Woo; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03 {+-} 0.08, and both lateral lingual foramina was 0.20 {+-} 0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9 mm {+-} 0.28, right lateral lingual foramen was 0.92 mm {+-} 0.23, and left lateral lingual foramen was 0.88 mm {+-} 0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  1. SADMFR guidelines for the use of Cone-Beam Computed Tomography/ Digital Volume Tomography.

    Science.gov (United States)

    Dula, Karl; Bornstein, Michael M; Buser, Daniel; Dagassan-Berndt, Dorothea; Ettlin, Dominik A; Filippi, Andreas; Gabioud, François; Katsaros, Christos; Krastl, Gabriel; Lambrecht, J Thomas; Lauber, Roland; Luebbers, Heinz-Theo; Pazera, Pawel; Türp, Jens C

    2014-01-01

    Cone-Beam Computed Tomography (CBCT) has been introduced in 1998. This radiological imaging procedure has been provided for dentistry and is comparable to computed tomography (CT) in medicine. It is expected that CBCT will have the same success in dental diagnostic imaging as computed tomography had in medicine. Just as CT is responsible for a significant rise in radiation dose to the population from medical X-ray diagnostics, CBCT studies will be accompanied by a significant increase of the dose to our patients by dentistry. Because of the growing concern for an uncritical and consequently rapidly increasing use of CBCT the Swiss Society of Dentomaxillofacial Radiology convened a first consensus conference in 2011 to formulate indications for CBCT, which can be used as guidelines. In this meeting, oral and maxillofacial surgery, orthodontics and temporomandibular joint disorders and diseases were treated and the most important and most experienced users of DVT in these areas were asked to participate. In general, a highly restrictive use of CBCT is required. Justifying main criterion for CBCT application is that additional, therapy-relevant information is expected that should lead to a significant benefit in patient care. All users of CBCT should have completed a structured, high-level training, just like that offered by the Swiss Society of Dentomaxillofacial Radiology.

  2. Current status of PET/CT in the diagnosis and follow up of lymphomas

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Buchpiguel

    2011-01-01

    Full Text Available Lymphomas are a heterogeneous group of malignancies that have a distinct biological behavior according to the subtype and degree of differentiation. Adequate staging, which has a direct impact on prognosis, is essential to properly plan therapy. Structural cross-sectional imaging, such as computed tomography, has been the standard imaging tool to stage and monitor patients with lymphoma. However, molecular imaging such as positron emission tomography has shown complementary diagnostic and prognostic values. This review discusses the current value of positron emission tomography imaging using 2-[fluorine-18]fluoro-2-deoxy-d-glucose in staging, restaging, monitoring and detecting relapse in Hodgkin's and non-Hodgkin lymphoma.

  3. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  4. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest...

  5. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Preite Martinez, A; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C

    2007-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  6. Analysis of imaging findings and clinical abnormalities in patients with lymphoma; Analise de achados de imagem e alteracoes clinicas em pacientes com linfoma

    Energy Technology Data Exchange (ETDEWEB)

    Caldas, Flavio Augusto Ataliba; Montomiya, Carolina Tsumori [Faculdade de Medicina de Marilia, SP (Brazil)]. E-mail: flavio_caldas@hotmail.com; Silva, Helena Cristina da [Faculdade de Medicina de Marilia, SP (Brazil). Hospital de Clinicas

    2002-04-01

    Computed tomography is currently the method of choice for the diagnostic and staging of lymphomas. Computed tomography enables accurate measurements of both tumor extent and volume and provides information that can be used to plan an appropriate strategy for the treatment. The purpose of the present article is to describe and analyze the chest and abdomen computed tomography and ultrasound findings in HIV-negative patients with lymphoma. Clinical abnormalities, such as the reason the patient sought medical assistance already showing evidence of lymphocytic disease (not yet diagnosed at this point) and the physical examination abnormalities seen on the first consultation were also studied. This study comprised 30 patients: 40% with non-Hodgkin lymphoma, 46,6% with Hodgkin lymphoma, 10% with Burkitt's lymphoma and 3,3% with lymphoblastic lymphoma. (author)

  7. [Role of cone-beam computed tomography in diagnostic otorhinolaryngological imaging].

    Science.gov (United States)

    Perényi, Ádám; Bella, Zsolt; Baráth, Zoltán; Magyar, Péter; Nagy, Katalin; Rovó, László

    2016-01-10

    Accurate diagnosis and preoperative planning in modern otorhinolaryngology is strongly supported by imaging with enhanced visualization. Computed tomography is often used to examine structures within bone frameworks. Given the hazards of ionizing radiation, repetitive imaging studies exponentially increase the risk of damages to radiosensitive tissues. The authors compare multislice and cone-beam computed tomography and determine the role, advantages and disadvantages of cone-beam computed tomography in otorhinolaryngological imaging. They summarize the knowledge from the international literature and their individual imaging studies. They conclude that cone-beam computed tomography enables high-resolution imaging and reconstruction in any optional plane and in space with considerably lower effective radiation dose. Cone-beam computed tomography with appropriate indications proved to be an excellent diagnostic tool in otorhinolaryngological imaging. It makes an alternative to multislice computed tomography and it is an effective tool in perioperative and postoperative follow-up, especially in those cases which necessitate repetitive imaging with computed tomography.

  8. [Spiral computed tomography in the diagnosis of limb osteomyelitis].

    Science.gov (United States)

    Vasil'ev, A Iu; Bulanova, T V; Onishchenko, M P

    2003-01-01

    The results of radiation studies in 121 patients of different age (4 to 75 years) examined for limb osteomyelitis are analyzed. All the patients underwent routine X-ray study and computed tomography (CT), 26 patients had X-ray fistulography; 8, linear tomography; 10, CT fistulography; 6, scintigraphy, and 15, ultrasound study. Acute hematogenous osteomyelitis (AHO), chronic hematogenous osteomyelitis (CHO), and atypical (here Garre's sclerosing osteomyelitis and Brodie's abscess) osteomyelitis were ascertained in 10.6, 26.4, and 10.1% of cases, respectively. Posttraumatic osteomyelitis was diagnosed in almost 50% of the patients. CT defined the phase of chronic limb osteomyelitis. Spiral CT has proven to be the most effective technique for diagnosing limb osteomyelitis as compared with routine X-ray study: the accuracy of X-ray study was 81.8%, its sensitivity, 84.9%, and specificity, 60.0% and those of computed tomography were 96.7, 99.1, and 80.0%, respectively.

  9. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly.

  10. Right parietal stroke with Gerstmann's syndrome. Appearance on computed tomography, magnetic resonance imaging, and single-photon emission computed tomography.

    Science.gov (United States)

    Moore, M R; Saver, J L; Johnson, K A; Romero, J A

    1991-04-01

    We examined a patient who exhibited Gerstmann's syndrome (left-right disorientation, finger agnosia, dyscalculia, and dysgraphia) in association with a perioperative stroke in the right parietal lobe. This is the first description of the Gerstmann tetrad occurring in the setting of discrete right hemisphere pathologic findings. A well-localized vascular lesion was demonstrated by computed tomography, magnetic resonance imaging, and single-photon emission computed tomographic studies. The patient had clinical evidence of reversed functional cerebral dominance and radiologic evidence of reversed anatomic cerebral asymmetries.

  11. The role of positron emission tomography/computed tomography in planning radiotherapy in endometrial cancer.

    Science.gov (United States)

    Simcock, Bryony; Narayan, Kailash; Drummond, Elizabeth; Bernshaw, David; Wells, Elizabeth; Hicks, Rodney J

    2015-05-01

    The optimal method of assessing disease distribution in endometrial cancer is widely debated. Knowledge of disease distribution assists in planning adjuvant radiotherapy; in this study we used positron emission tomography/computed tomography (PET/CT) to assess disease distribution before radiotherapy. Seventy-three consecutive patients referred to the Peter MacCallum Cancer Centre for adjuvant radiotherapy for endometrial cancer, with either high-risk disease after a hysterectomy or recurrent disease, had a PET/CT before treatment. The findings on PET/CT and clinical course were recorded. PET/CT found additional disease in 35% of postoperative patients, changing planned treatment in 31%. In the group with known recurrence, additional disease was found in 72%, changing management in 36%. PET/CT is a valuable tool for planning radiotherapy in endometrial cancer.

  12. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Science.gov (United States)

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  13. Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Dongmei; Zhu, Shouping, E-mail: zhusp2009@gmail.com; Chen, Xueli; Chao, Tiantian; Cao, Xu; Zhao, Fengjun; Huang, Liyu; Liang, Jimin [Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education and School of Life Science and Technology, Xidian University, Xi' an, Shaanxi 710071 (China)

    2014-11-10

    X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging.

  14. Reconstruction Algorithms for Positron Emission Tomography and Single Photon Emission Computed Tomography and their Numerical Implementation

    CERN Document Server

    Fokas, A S; Marinakis, V

    2004-01-01

    The modern imaging techniques of Positron Emission Tomography and of Single Photon Emission Computed Tomography are not only two of the most important tools for studying the functional characteristics of the brain, but they now also play a vital role in several areas of clinical medicine, including neurology, oncology and cardiology. The basic mathematical problems associated with these techniques are the construction of the inverse of the Radon transform and of the inverse of the so called attenuated Radon transform respectively. We first show that, by employing mathematical techniques developed in the theory of nonlinear integrable equations, it is possible to obtain analytic formulas for these two inverse transforms. We then present algorithms for the numerical implementation of these analytic formulas, based on approximating the given data in terms of cubic splines. Several numerical tests are presented which suggest that our algorithms are capable of producing accurate reconstruction for realistic phanto...

  15. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  16. Diagnostic performance of exercise bicycle testing and single-photon emission computed tomography: Comparison with 64-slice computed tomography coronary angiography

    NARCIS (Netherlands)

    A.C. Weustink (Annick); L.A.E. Neefjes (Lisan); A. Rossi (Alexia); W.B. Meijboom (Willem Bob); K. Nieman (Koen); E. Capuano (Ermanno); H. Boersma (Eric); N.R.A. Mollet (Nico); G.P. Krestin (Gabriel); P.J. de Feyter (Pim)

    2012-01-01

    textabstractTo conduct a comparison of the diagnostic performance of exercise bicycle testing and singlephoton emission computed tomography (SPECT) with computed tomography coronary angiography (CTCA) for the detection of obstructive coronary artery disease (CAD) in patients with stable angina. 376

  17. 2-[18F]-fluoro-2-desoxy-D-glucose positron emission tomography initial staging impacts on survival in Hodgkin lymphoma

    Institute of Scientific and Technical Information of China (English)

    Juliano; J; Cerci; Camila; C; G; Linardi; Luís; F; Pracchia; José; Soares; Junior; Evelinda; Trindade; Dominique; Delbeke; Rodrigo; J; Cerci; Robert; Carr; José; C; Meneghetti; Valeria; Buccheri

    2013-01-01

    AIM:To assess the prognostic value and risk classification improvement of metabolic staging(MS)with Initial2-[18F]-fluoro-2-desoxy-D-glucose positron emission tomography(FDG-PET)in initial staging of Hodgkin’s Lymphoma(HL)patients to predict 5 years overall survival(5y-OS)and event free survival(EFS).METHODS:A total of 275 patients were included in this retrospective study,155 patients were staged with conventional anatomical staging(AS),and 120 also submitted to MS(FDG-PET).Prognostic analysis compared 5y-OS and 5y-EFS of patients staged with AS and MS.Risk-adjusted models incorporated clinical risk factors,computed tomography and FDG-PET staging.RESULTS:During the follow up of 267 evaluated patients,220(122 AS and 98 MS)achieved complete remission after first-line therapy(median follow-up:70±29 mo),treatment failure occurred in 79 patients and 34 died.The 5y-EFS for early vs advanced disease in AS patients was 79.3%and 66.7%,and 85.6%and53.6%in MS patients,respectively(P<0.01).The5y-OS for early and advanced disease with AS was91.3%and 81.5%,and 97.5%and 80.7%for patients staged with MS,respectively.Cox proportional hazards analysis demonstrated that FDG-PET added signifcant prognostic information and improved risk prediction(P=0.02).CONCLUSION:Initial staging FDG-PET could be used as an accurate and independent predictor of OS and EFS in HL,with impact in 5y-EFS and OS.

  18. Utility of emergency cranial computed tomography in patients without trauma.

    Science.gov (United States)

    Narayanan, Vignesh; Keniston, Angela; Albert, Richard K

    2012-09-01

    The objectives of this study were to determine, in patients admitted to the hospital from the emergency department (ED) without evidence of trauma, 1) the prevalence of clinically important abnormalities on cranial computed tomography (CCT) and 2) the frequency of emergent therapeutic interventions required because of these abnormalities. The authors retrospectively reviewed the records of all patients from 2007 between the ages of 18 and 89 years who had CCT as part of their ED evaluations prior to hospitalization. Patients with any indication of trauma were excluded, as were those who had a lumbar puncture (LP). Chief complaint, results of the ED neurologic examination, tomogram findings, and whether patients had emergent interventions were recorded. Patients presenting with altered mental status (AMS) were analyzed separately. Of the 766 patients meeting inclusion criteria, 83 (11%) had focal neurologic findings, and 61 (8%) had clinically important abnormalities on computed tomography. Emergent interventions occurred in only 12 (1.6%), 11 (92%) of whom had focal neurologic findings. In the subgroup of 287 patients with AMS as their presenting problem, 14 (4.9%) had focal findings, six (2%) had clinically important abnormalities on tomography, and only two (0.7%) required emergent interventions, both of whom had focal findings. Patients presenting with AMS were less likely to have positive findings on tomography (odds ratio [OR] = 0.16, 95% confidence interval [CI] = 0.07 to 0.39). Patients presenting with motor weakness or speech abnormalities, or who were unresponsive, were more likely to have positive findings on tomography (OR = 4.7, 95% CI = 2.6 to 8.6; OR = 4.4, 95% CI = 1.5 to 2.7; and OR = 3.3, 95% CI = 1.6 to 7.1, respectively). Of patients without evidence of trauma who receive CCT in the ED, the prevalence of focal neurologic findings and clinically important abnormalities on tomography is low, the need for emergent intervention is very low, and the

  19. A Rare Presentation of In Situ Mantle Cell Lymphoma and Follicular Lymphoma: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Josephine Taverna

    2014-01-01

    Full Text Available A 65-year-old gentleman presented with left groin swelling over the course of two months. Physical exam revealed nontender left inguinal adenopathy, and computed tomography scans detected multiple lymph nodes in the mesenteric, aortocaval, and right common iliac regions. An excisional lymph node biopsy was performed. Pathologic evaluation demonstrated follicular center site which stained positive for PAX5, CD20, CD10, Bcl-2, Bcl-6, and mantle zone cells. These findings demonstrated CCND1 and CD5 positivity, suggesting composite lymphoma comprising follicular lymphoma (FL with in situ mantle cell lymphoma (MCLIS. FL is known as indolent non-Hodgkin lymphoma; however, the clinical significance of a coexisting MCLIS continues to be elusive, and optimal management of these patients remains largely unknown. This case illustrates the diagnostic and therapeutic challenges of composite lymphomas. This paper also discusses advances in molecular pathogenesis and lymphoma genomics which offer novel insights into these rare diseases.

  20. First experiences from Copenhagen with paediatric single photon emission computed tomography/computed tomography

    DEFF Research Database (Denmark)

    Mortensen, Jann; Bech, Birthe Højlund; Højgaard, Liselotte

    2011-01-01

    OBJECTIVE: This study evaluates the diagnostic value of single photon emission computed tomographic (SPECT)/multislice computed tomographic (MSCT) fusion images compared with planar scintigraphy in children. METHODS: Fifteen children [eight girls, mean age 13 years (range 2-17 years)] who were...

  1. F-18 Fluorodeoxy Glucose Positron Emission Tomography/Computed Tomography Findings in a Rare Case of Penile Leiomyosarcoma

    Directory of Open Access Journals (Sweden)

    Kuruva Manohar

    2011-01-01

    Full Text Available Penile cancer is a rare entity accounting for only 0.4% all male malignancies. Penile leiomyosarcomas are even rarer with only around 35 cases reported in literature. We report a rare case of penile leiomyosarcoma illustrating F-18 Fluorodeoxy glucose (FDG positron emission tomography/computed tomography (PET/CT features and histopathology correlation.

  2. Primary bilateral adrenal non-Hodgkin's lymphoma associated with normal adrenal function.

    Science.gov (United States)

    Gu, Bin; Ding, Qiang; Xia, Guowei; Fang, Zujun; Fang, Jie; Jiang, Haowen; Yao, Mengshu

    2009-04-01

    Primary bilateral adrenal non-Hodgkin's lymphoma is rare. Adrenal insufficiency or adrenal failure as a result of tumor destruction is the main pathophysiological change of most cases. Normal adrenal function despite bulky bilateral adrenal masses is extremely rare. We present a case of primary bilateral adrenal non-Hodgkin's lymphoma associated with normal adrenal function. Positron emission tomography-computed tomography is helpful to the diagnosis.

  3. Successful treatment of a free-moving abdominal mass with radiation therapy guided by cone-beam computed tomography: a case report

    Directory of Open Access Journals (Sweden)

    Shihadeh Ferial

    2010-10-01

    Full Text Available Abstract Introduction Because tumors in the abdomen can change position, targeting these tumors for radiation therapy should be done with caution; use of daily image-guided radiation therapy is advised. Case presentation We report the case of a 72-year-old Caucasian man with recurrent mantle cell lymphoma who was referred for palliative radiation therapy for an abdominopelvic tumor. Computed tomography was used to generate images for radiation treatment planning. Comparison of those planning images with a positron emission tomography/computed tomography scan ordered during the planning period revealed that the tumor had moved from one side of the abdomen to the other during the three-day interval between scans. To account for this unusual tumor movement, we obtained a second set of planning computed tomography scans and used a Varian cone-beam computed tomography scanner with on-board imaging capability to target the tumor before each daily treatment session, leading to successful treatment and complete resolution of the mass. Conclusion Abdominal masses associated with the mesentery should be considered highly mobile; thus, radiation therapy for such masses should be used with the utmost caution. Modern radiation therapy techniques offer the ability to verify the tumor location in real time and shift the treatment ports accordingly over the course of treatment.

  4. Paradigm of pretest risk stratification before coronary computed tomography

    DEFF Research Database (Denmark)

    Jensen, Jesper Møller; Øvrehus, Kristian; Nielsen, Lene H

    2009-01-01

    BACKGROUND: The optimal method of determining the pretest risk of coronary artery disease as a patient selection tool before coronary multidetector computed tomography (MDCT) is unknown. OBJECTIVE: We investigated the ability of 3 different clinical risk scores to predict the outcome of coronary...... by receiver operating characteristic analysis. The distribution of low-, intermediate-, and high-risk persons, respectively, was established and compared for each of the 3 risk models. RESULTS: Overall, all risk prediction models performed equally well. However, the Duke risk model classified the low......-risk patients more correctly than did the other models (P value of the Duke risk model was superior to the other risk models (P

  5. Precision Medicine and PET/Computed Tomography: Challenges and Implementation.

    Science.gov (United States)

    Subramaniam, Rathan M

    2017-01-01

    Precision Medicine is about selecting the right therapy for the right patient, at the right time, specific to the molecular targets expressed by disease or tumors, in the context of patient's environment and lifestyle. Some of the challenges for delivery of precision medicine in oncology include biomarkers for patient selection for enrichment-precision diagnostics, mapping out tumor heterogeneity that contributes to therapy failures, and early therapy assessment to identify resistance to therapies. PET/computed tomography offers solutions in these important areas of challenges and facilitates implementation of precision medicine. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Laryngotracheobronchial papillomatosis: findings on computed tomography scans of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Araujo Neto, Cesar de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Radiologia; Meirelles, Gustavo Souza Portes [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil); Irion, Klaus Loureiro [The Royal Liverpool University Hospital, Liverpool (United Kingdom); Zanetti, Glaucia [Faculdade de Medicina de Petropolis (FMP), RJ (Brazil); Missrie, Israel [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Diagnostico por Imagem; Sato, Juliana [Universidade Federal de Sao Paulo (UNIFESP-EPM), SP (Brazil). Dept. de Otorrinolaringologia e Cirurgia de Cabeca e Pescoco

    2008-12-15

    Objectives: To present the findings of computed tomography (CT) scans of the chest in patients with laryngotracheobronchial papillomatosis. Methods: We retrospectively analyzed CT scans of eight patients, five males and three females, ranging from 5 to 18 years of age with a mean age of 10.5 years. Images were independently reviewed by two radiologists. In discrepant cases, a consensus was reached. Results: The most common CT findings were intratracheal polypoid lesions and pulmonary nodules, many of which were cavitated. Conclusions: In patients with laryngotracheobronchial papillomatosis, the most common tomographic finding was the combination of intratracheal polypoid lesions and multiple pulmonary nodules, many of which were cavitated. (author)

  7. Value of computed tomography in patients with mucopolysaccharidosis

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, J.; Grebell, F.S.

    1987-11-01

    Cranial computed tomography (CT) was performed on 11 cases of mucopolysaccharidosis (MPS) IVA (Morquio syndrome). Our results suggest that although having normal intelligence CT changes may be seen with increasing age. In two cases white matter low density was found and in a third there was gross dilatation of the ventricles, basal cisterns and subarachnoid space. Nine other patients with various types of mucopolysaccharidosis also had cranial CT performed and in general those types associated with mental retardation showed changes although there was an interesting exception involving a case of MPS IIIA who had a normal CT scan.

  8. Computed Tomography Appearances of Various Complications Associated with Pancreatic Pseudocysts

    Energy Technology Data Exchange (ETDEWEB)

    Cheol Kim, Hyun; Mo Yang, Dal; Jung Kim, Hyoung; Ho Lee, Dong; Tae Ko, Young; Won Lim, Joo (Dept. of Radiology, East-West Neo Medical Center, Kyung-Hee Univ., Seoul (Korea))

    2008-09-15

    Most pancreatic pseudocysts are common complications of acute or chronic pancreatitis. They usually occur within the pancreas or in peripancreatic tissues, and are visualized as round or oval fluid collections with thin or thick walls on computed tomography (CT) scans. However, pancreatic pseudocysts are often combined with various complications, e.g., various organ involvements, infection, hemorrhage with pseudoaneurysm formation, rupture with fistula formation, or gastrointestinal or biliary obstruction, which may necessitate prompt intervention or surgery. This review illustrates the CT appearances of various complications associated with pancreatic pseudocysts

  9. Material reconstruction for spectral computed tomography with detector response function

    Science.gov (United States)

    Liu, Jiulong; Gao, Hao

    2016-11-01

    Different from conventional computed tomography (CT), spectral CT using energy-resolved photon-counting detectors is able to provide the unprecedented material compositions. However accurate spectral CT needs to account for the detector response function (DRF), which is often distorted by factors such as pulse pileup and charge-sharing. In this work, we propose material reconstruction methods for spectral CT with DRF. The simulation results suggest that the proposed methods reconstructed more accurate material compositions than the conventional method without DRF. Moreover, the proposed linearized method with linear data fidelity from spectral resampling had improved reconstruction quality from the nonlinear method directly based on nonlinear data fidelity.

  10. Normal postperative computed tomography findings after avariety of pancreatic surgeries

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Ji Won; Hwang, Ho Kyoung; Lee, Min Wook; Kim, Ki Whang; Kang, Chang Moo; Kim, Myeong Jin; Chung, Yong Eun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Pancreatic surgery remains the only curative treatment for pancreatic neoplasms, and plays an important role in the management of medically intractable diseases. Since the original Whipple operation in the 20th century, surgical techniques have advanced, resulting in decreased postoperative complications and better clinical outcomes. Normal postoperative imaging findings vary greatly depending on the surgical technique used. Radiologists are required to be familiar with the normal postoperative imaging findings, in order to distinguish from postoperative complications or tumor recurrence. In this study, we briefly review a variety of surgical techniques for the pancreas, and present the normal postoperative computed tomography findings.

  11. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  12. Computed tomography in the evaluation of thyroid disease

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-05-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum.

  13. Aortic valve area assessed with 320-detector computed tomography

    DEFF Research Database (Denmark)

    Larsen, Linnea Hornbech; Kofoed, Klaus Fuglsang; Carstensen, Helle Gervig;

    2014-01-01

    To evaluate the diagnostic accuracy of aortic valve area (AVA) assessment with 320-detector Computed Tomography (MDCT) compared to transthoracic echocardiography (TTE) in a population with mild to severe aortic valve stenosis. AVA was estimated in 169 patients by planimetry on MDCT images (AVAMDCT......) and by the continuity equation with TTE (AVATTE). To generate a reference AVA (AVAREF) we used the stroke volume from MDCT divided by the velocity time integral from CW Doppler by TTE (according to the continuity equation: stroke volume in LVOT = stroke volume passing the aortic valve). AVAREF was used as the reference...

  14. Multidetector computer tomography: evaluation of blunt chest trauma in adults.

    Science.gov (United States)

    Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  15. Incidental findings on cone beam computed tomography: Relate and relay

    Directory of Open Access Journals (Sweden)

    Suhas P Pande

    2015-01-01

    Full Text Available Objective: To evaluate the presence of incidental findings on cone beam computed tomography (CBCT images and to recognize their clinical importance. Materials and Methods: A total of 700 CBCT scans between January 2013 to August 2014 at Government Dental College and Hospital were evaluated retrospectively. Results: 459 incidental findings (65.57% were observed in 700 patients. Most common individual incidental finding was mucosal thickening (119 followed by pineal/habenula calcification (99 and choroid plexus (77. Conclusion: The oral and maxillofacial radiologist should carefully interpret all scans and should not ignore the incidental findings and hence avoid untoward snowballing effects.

  16. X-ray computed tomography investigations of Cucuteni ceramic statuettes

    Directory of Open Access Journals (Sweden)

    Carmen Pavel

    2013-12-01

    Full Text Available Deciphering the internal structure of prehistoric artefacts can provide spectacular insights that might help us understand the people who made them. In order to preserve the integrity of these relics of past civilisations, it is desirable to make such investigations using non-destructive techniques. Recent decades have witnessed a growth in the X-ray computed tomography (CT applications in the study of cultural heritage objects. This paper presents and discusses tomographic investigations of two Cucuteni ceramic statuettes discovered in Romania. The study was made with a CT device specially designed for archaeometric applications.

  17. Differentiation of orbital cellulitis from preseptal cellulitis by computed tomography.

    Science.gov (United States)

    Goldberg, F; Berne, A S; Oski, F A

    1978-12-01

    Computed tomography (CT) was used in the management of four patients with periorbital inflammation. These patients were selected for CT scanning because of the difficulty, on clinical examination alone, in determining the degree of orbital disease. The CT scans confirmed the presence and defined the location of an orbital abscess in three patients and eliminated the presence of an abscess in the fourth. On the basis of this experience, CT scanning is recommended in the evaluation of children with periorbital inflammation in whom proptosis, ophthalmoplegia, or loss of visual acuity develops, or in whom severe eyelid edema prevents adequate eye examination.

  18. Unusual causes of colonic wall thickening on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Turner, D.R.; Markose, G.; Arends, M.J.; Ng, C.S.; Freeman, A.H

    2003-03-01

    Computed tomography (CT) appearances in 'colitis' are often non-specific, and include mural thickening and mesenteric fat stranding. In the western world, the majority of cases will have, or be subsequently diagnosed with, inflammatory bowel disease, pseudomembranous colitis or ischaemic colitis. However, other rare conditions may also produce these rather non-specific signs. We present a number of cases demonstrating colonic wall thickening on CT due to rarer diagnoses, which are correlated with the histopathological features. Some of these CT appearances have not been described previously in the literature.

  19. Bleeding Meckel's diverticulum diagnosis: an unusual indication for computed tomography.

    Science.gov (United States)

    Danzer, D; Gervaz, P; Platon, A; Poletti, P A

    2003-01-01

    Despite the wide use of modern investigation techniques, the diagnosis of complications related to Meckel's diverticulum (MD) remains difficult. Arteriography is commonly indicated for acute bleeding, and radionuclide scans may help in identifying the site of intestinal hemorrhage. In contrast, computed tomography (CT) is usually considered little use in the diagnosis of bleeding MD. We present the case of a young patient with massive gastrointestinal hemorrhage, in whom the diagnosis of MD bleeding was preoperatively made with contrast-enhanced CT after two negatives arteriographies.

  20. Cone-beam computed tomography: A miracle for orthodontics!

    Directory of Open Access Journals (Sweden)

    Jeevan M Khatri

    2015-01-01

    Full Text Available The branch of oral medicine and radiology has always played a role of back stage worker for the branch of orthodontics and dentofacial orthopaedics. It would have been difficult for an orthodontist to gift the bright smiles to his/her patients without the 2D and 3D black and white pictures provided by the oral radiologist. Moreover, the series of advances in the various imaging modalities are playing the role of a magician for the branch of orthodontia. The present article provides valuable information about one such miracle for the field of orthodontics-cone beam computed tomography (CBCT.

  1. Computed tomography of the thymus gland in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Thorvinger, B.; Lyttkens, K.; Samuelsson, L.

    Sixteen consecutive patients with myasthenia gravis were examined by computed tomography (CT) before thymectomy. Surgical and histologic findings were compared with those obtained at CT. The results, like those of most other recent studies, indicate that CT is a reliable method for identifying thymoma. In all three patients with thymoma, and in five out of eight patients with hyperplasia, the lesion was observed at CT, giving an overall accuracy of 80%. Although tymic hyperplasia is a basically histological diagnosis an enlarged gland may give a correct diagnosis of this abnormality.

  2. The value of computed tomography in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L.R.; Muhm, J.R.; Sheedy, P.F. II; Unni, K.K.; Bernatz, P.E.; Hermann, R.C. Jr.

    1983-01-01

    In a 5 year study, 19 patients with myasthenia gravis were studied by computed tomography (CT) and underwent thymectomy. CT was accurate in detecting the nine true thymic masses but could not differentiate thymomas from nonthymomatous masses, including thymic cysts. No thymoma was found in a patient under 25 years of age. In one case, the 18 sec scanner could not differentiate a large gland from a thymoma. In eight cases, glands with histologic thymic hyperplasia and histologically normal thymus appeared to be similar and could not be differentiated by CT.

  3. Urologic applications of multiplanar and three-dimensional computed tomography.

    Science.gov (United States)

    Olson, M C; Posniak, H V

    1995-01-01

    The introduction of helical computed tomography (CT) has resulted in improved quality of multiplanar reformations and three-dimensional reconstructions in the chest and abdomen and has made CT angiography a clinical reality. These imaging techniques are useful for evaluating the urinary tract, adding a new dimension to its display, resulting in improved diagnosis of renal and perirenal disease. This article reviews the indications and techniques utilized for multiplanar and three-dimensional CT for urology. The advantages and limitations are discussed, and normal and pathologic findings in the urinary tract illustrated.

  4. PRaVDA: High Energy Physics towards proton Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Price, T., E-mail: t.price@bham.ac.uk

    2016-07-11

    Proton radiotherapy is an increasingly popular modality for treating cancers of the head and neck, and in paediatrics. To maximise the potential of proton radiotherapy it is essential to know the distribution, and more importantly the proton stopping powers, of the body tissues between the proton beam and the tumour. A stopping power map could be measured directly, and uncertainties in the treatment vastly reduce, if the patient was imaged with protons instead of conventional x-rays. Here we outline the application of technologies developed for High Energy Physics to provide clinical-quality proton Computed Tomography, in so reducing range uncertainties and enhancing the treatment of cancer.

  5. Value of computed tomography scanning in chondromalacia patellae

    Energy Technology Data Exchange (ETDEWEB)

    Boven, F.; Bellemans, M.A.; Geurts, J.; de Boeck, H.; Potvliege, R.

    1982-06-01

    Sixtyseven patients with pain in the knee were studied. A computed tomography (CT) score indicating chondromalacia was devised, based on the results of CT after arthrography. This score takes account of the regularity, the congruity, and the imbibition of contrast material. Thus the patients could be divided into four groups: those who definitely have chondromalacia (++), probably (+), probably not (+-), and definitely not (-). These results were compared with the clinical diagnosis based on clinical signs, arthroscopy, or operation. Eighteen patients had clinically proved chondromalacia, CT scored 14++, 3+ and 1+-. Twentynine patients had no chondromalacia, CT scored 19-, 8+-, and 2+. Twenty patients had an uncertain clinical diagnosis. Arthrography was less accurate in detecting chondromalacia.

  6. Micro Computer Tomography for medical device and pharmaceutical packaging analysis.

    Science.gov (United States)

    Hindelang, Florine; Zurbach, Raphael; Roggo, Yves

    2015-04-10

    Biomedical device and medicine product manufacturing are long processes facing global competition. As technology evolves with time, the level of quality, safety and reliability increases simultaneously. Micro Computer Tomography (Micro CT) is a tool allowing a deep investigation of products: it can contribute to quality improvement. This article presents the numerous applications of Micro CT for medical device and pharmaceutical packaging analysis. The samples investigated confirmed CT suitability for verification of integrity, measurements and defect detections in a non-destructive manner. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Computed tomography in the evaluation of plexopathies and proximal neuropathies

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, J.D. (McGill Univ., Montreal, Quebec (Canada). Dept. of Neurology and Neurosurgery); Schmidt, B. (McGill Univ., Montreal, Quebec (Canada). Dept. of Radiology); Wee, R. (Montreal General Hospital, Quebec (Canada))

    1983-11-01

    The article describes nine patients with plexopathies or proximal mononeuropathies due to mass lesions. In four, computed tomography (CT) was the only radiological technique to show the cause of the neuropathy. In five patients, CT either unequivocally confirmed the presence of an abnormality or was superior to other imaging techniques in showing its full anatomical extent. CT scanning is a valuable aid in the assessment of lesions of the peripheral nervous system, particularly plexopathies and mononeuropathies caused by retroperitoneal, pelvic or superior pulmonary sulcus tumors.

  8. Angiography and computed tomography in cerebro-arterial occlusive diseases

    Energy Technology Data Exchange (ETDEWEB)

    Bradac, G.B.; Oberson, R.

    1983-01-01

    This second edition provides an exposition of occlusive diseases of the extra- and intracranial arterial circulation. The contents include: (1) pathology of the causes of cerebrovascular arterial occlusion; (2) the indications, hazards, technical aspects, and routine technique of cerebral angiography; (3) angiographic findings of the extracranial segments of the circulation to the brain; (4) computed tomography in the diagnosis of cerebrovascular diseases; (5) other investigations in the diagnosis of cerebrovascular occlusive disease; (6) conclusive considerations on the pathogenesis of transient ischemic attacks and infarctions.

  9. PET/Computed Tomography in Renal, Bladder, and Testicular Cancer.

    Science.gov (United States)

    Bouchelouche, Kirsten; Choyke, Peter L

    2015-07-01

    Imaging plays an important role in the clinical management of cancer patients. Hybrid imaging with PET/computed tomography (CT) is having a broad impact in oncology, and in recent years PET/CT is beginning to have an impact in urooncology. In both bladder and renal cancers, there is a need to study the efficacy of other tracers than F-18 fluorodeoxyglucose (FDG), particularly tracers with limited renal excretion. Thus, new tracers are being introduced. This review focuses on the clinical role of FDG and other PET agents in renal, bladder, and testicular cancers.

  10. Improved proton computed tomography by dual modality image reconstruction

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Bassler, Niels; Petersen, Jørgen B.B.;

    2014-01-01

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full...... nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully...

  11. Characterizing Green Fiber Bottle Prototypes Using Computed Tomography

    DEFF Research Database (Denmark)

    Saxena, Prateek; Bissacco, Giuliano; Stolfi, Alessandro

    2017-01-01

    in the desired shape and structure. However, there are certain limitations associated to the product characterization using tactile measuring methods. In this work, a new approach has been applied for defect analysis and quality control of non-homogenous prototype paper products using computed tomography.......Due to ever increasing demand of sustainability and biodegradability, there arises a need to develop environmental friendly packaging products. Green fiber bottle is a packaging product for carbonated beverages, made out of cellulose fibers. The production process accounts for moulding paper pulp...

  12. Benign breast lesions detected by positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Benveniste, Ana P., E-mail: apbenveniste@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Yang, Wei, E-mail: wyang@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Benveniste, Marcelo F., E-mail: mfbenveniste@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Mawlawi, Osama R., E-mail: omawlawi@mdanderson.org [Department of imaging physics, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Marom, Edith M., E-mail: emarom@mdanderson.org [Department of Diagnostic Radiology,The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-15

    {sup 18}F-fluorodeoxyglucose positron emission computed tomography (FDG PET-CT) is widely used in the initial staging and response evaluation of patients with malignancy. This review describes a spectrum of benign breast findings incidentally detected by FDG PET-CT at staging that may be misinterpreted as malignancy. We describe the pattern of distribution and intensity of FDG uptake in a spectrum of benign breast diseases with their corresponding typical morphological imaging characteristics to help the nuclear medicine physician and/or general radiologist identify benign lesions, avoiding unnecessary breast imaging work-up and biopsies.

  13. Temporomandibular joint computed tomography: development of a direct sagittal technique

    Energy Technology Data Exchange (ETDEWEB)

    van der Kuijl, B.; Vencken, L.M.; de Bont, L.G.; Boering, G. (Univ. of Groningen, (Netherlands))

    1990-12-01

    Radiology plays an important role in the diagnosis of temporomandibular disorders. Different techniques are used with computed tomography offering simultaneous imaging of bone and soft tissues. It is therefore suited for visualization of the articular disk and may be used in patients with suspected internal derangements and other disorders of the temporomandibular joint. Previous research suggests advantages to direct sagittal scanning, which requires special positioning of the patient and a sophisticated scanning technique. This study describes the development of a new technique of direct sagittal computed tomographic imaging of the temporomandibular joint using a specially designed patient table and internal light visor positioning. No structures other than the patient's head are involved in the imaging process, and misleading artifacts from the arm or the shoulder are eliminated. The use of the scanogram allows precise correction of the condylar axis and selection of exact slice level.

  14. Computed tomography of the craniocervical junction in rheumatoid arthritis.

    Science.gov (United States)

    Castor, W R; Miller, J D; Russell, A S; Chiu, P L; Grace, M; Hanson, J

    1983-02-01

    Thirty-three patients with rheumatoid arthritis had computed tomographic examination of the craniocervical junction. This demonstrated soft tissue features which have not previously been described in published reports. A low attenuation lesion between the odontoid and the transverse ligament shown in 11 patients was considered a premonitory sign of rupture of the transverse ligament or a manifestation of active disease. Computed tomography revealed spinal cord compression in 3 patients and ligamentous changes in the transverse ligament and the alar and spinal ligaments in 26 patients. Erosion of the odontoid was shown in 19 patients and subluxation in 20 patients. No relationship could be found between the clinical signs and symptoms and the radiological abnormalities except in the case of cord compression.

  15. Denoising Message Passing for X-ray Computed Tomography Reconstruction

    CERN Document Server

    Perelli, Alessandro; Can, Ali; Davies, Mike E

    2016-01-01

    X-ray Computed Tomography (CT) reconstruction from sparse number of views is becoming a powerful way to reduce either the radiation dose or the acquisition time in CT systems but still requires a huge computational time. This paper introduces an approximate Bayesian inference framework for CT reconstruction based on a family of denoising approximate message passing (DCT-AMP) algorithms able to improve both the convergence speed and the reconstruction quality. Approximate Message Passing for Compressed Sensing has been extensively analysed for random linear measurements but there are still not clear solutions on how AMP should be modified and how it performs with real world problems. In particular to overcome the convergence issues of DCT-AMP with structured measurement matrices, we propose a disjoint preconditioned version of the algorithm tailored for both the geometric system model and the noise model. In addition the Bayesian DCT-AMP formulation allows to measure how the current estimate is close to the pr...

  16. Computed tomography findings of paracoccidiodomycosis in musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Lima Junior, Francisco Valtenor Araujo; Savarese, Leonor Garbin; Monsignore, Lucas Moretti; Martinez, Roberto; Nogueira-Barbosa, Marcello Henrique, E-mail: fvaltenor@gmail.com [Universidade de Sao Paulo (FM/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina

    2015-01-15

    Objective: to evaluate musculoskeletal involvement in paracoccidioidomycosis at computed tomography. Materials and methods: development of a retrospective study based on a review of radiologic and pathologic reports in the institution database. Patients with histopathologically confirmed musculoskeletal paracoccidioidomycosis and submitted to computed tomography were included in the present study. The imaging findings were consensually described by two radiologists. In order to avoid bias in the analysis, one patient with uncountable bone lesions was excluded from the study. Results: a total of seven patients were included in the present study. A total of 18 bone lesions were counted. The study group consisted of 7 patients. A total number of 18 bone lesions were counted. Osteoarticular lesions were the first manifestation of the disease in four patients (57.14%). Bone lesions were multiple in 42.85% of patients. Appendicular and axial skeleton were affected in 85.71% and 42.85% of cases, respectively. Bone involvement was characterized by well-demarcated osteolytic lesions. Marginal osteosclerosis was identified in 72.22% of the lesions, while lamellar periosteal reaction and soft tissue component were present in 5.55% of them. One patient showed multiple small lesions with bone sequestra. Conclusion: paracoccidioidomycosis can be included in the differential diagnosis of either single or multiple osteolytic lesions in young patients even in the absence of a previous diagnosis of pulmonary or visceral paracoccidioidomycosis. (author)

  17. Limited-data computed tomography algorithms for the physical sciences.

    Science.gov (United States)

    Verhoeven, D

    1993-07-10

    Five limited-data computed tomography algorithms are compared. The algorithms used are adapted versions of the algebraic reconstruction technique, the multiplicative algebraic reconstruction technique, the Gerchberg-Papoulis algorithm, a spectral extrapolation algorithm descended from that of Harris [J. Opt. Soc. Am. 54, 931-936 (1964)], and an algorithm based on the singular value decomposition technique. These algorithms were used to reconstruct phantom data with realistic levels of noise from a number of different imaging geometries. The phantoms, the imaging geometries, and the noise were chosen to simulate the conditions encountered in typical computed tomography applications in the physical sciences, and the implementations of the algorithms were optimized for these applications. The multiplicative algebraic reconstruction technique algorithm gave the best results overall; the algebraic reconstruction technique gave the best results for very smooth objects or very noisy (20-dB signal-to-noise ratio) data. My implementations of both of these algorithms incorporate apriori knowledge of the sign of the object, its extent, and its smoothness. The smoothness of the reconstruction is enforced through the use of an appropriate object model (by use of cubic B-spline basis functions and a number of object coefficients appropriate to the object being reconstructed). The average reconstruction error was 1.7% of the maximum phantom value with the multiplicative algebraic reconstruction technique of a phantom with moderate-to-steep gradients by use of data from five viewing angles with a 30-dB signal-to-noise ratio.

  18. Computed tomography of intra - and extramural ethmoid cells: iconographic essay

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Fabricio Guimaraes [McGill University Health Centre (MUHC), Montreal, QC (Canada). Montreal General Hospital; Jovem, Cassio Lemos [Med Imagem, Teresina, PI (Brazil); Moura, Leonardo de Oliveira [Centro de Treinamento em Imagenologia (CETRIM), Joao Pessoa, PB (Brazil)

    2011-09-15

    The development of the paranasal sinuses is an intricate process that begins in the intrauterine life and terminates in early adulthood. Among the paranasal sinuses, the ethmoid cells or labyrinth are probably the most complex structures, being associated with the highest number of normal variants. Variations in the pattern of pneumatization of the ethmoid cells can be divided into intra - and extramural cells. Intramural cells are those which develop within the ethmoid labyrinth. Extramural cells are those that develop isolatedly. Computed tomography is the most useful tool in the evaluation of inflammatory processes of the paranasal sinuses. Computed tomography also plays a relevant role in the preoperative planning as well as in the postoperative follow-up, since it demonstrates exact anatomical details of normal structures with accuracy in the detection of variants. In the present pictorial essay, the authors describe the most common anatomical variants of the ethmoid labyrinth and their relationship with adjacent structures. Endoscopic sinonasal surgery has become increasingly less invasive, requiring more detailed anatomical imaging of this region. (author)

  19. Incidental cardiac findings on computed tomography imaging of the thorax

    Directory of Open Access Journals (Sweden)

    El-Gendi Hossam

    2010-12-01

    Full Text Available Abstract Background Investigation of pulmonary pathology with computed tomography also allows visualisation of the heart and major vessels. We sought to explore whether clinically relevant cardiac pathology could be identified on computed tomography pulmonary angiograms (CTPA requested for the exclusion of pulmonary embolism (PE. 100 consecutive CT contrast-enhanced pulmonary angiograms carried out for exclusion of PE at a single centre were assessed retrospectively by two cardiologists. Findings Evidence of PE was reported in 5% of scans. Incidental cardiac findings included: aortic wall calcification (54%, coronary calcification (46%, cardiomegaly (41%, atrial dilatation (18%, mitral annulus calcification (15%, right ventricular dilatation (11%, aortic dilatation (8% and right ventricular thrombus (1%. Apart from 3 (3% reports describing cardiomegaly, no other cardiac findings were described in radiologists' reports. Other reported pulmonary abnormalities included: lung nodules (14%, lobar collapse/consolidation (8%, pleural effusion (2%, lobar collapse/consolidation (8%, emphysema (6% and pleural calcification (4%. Conclusions CTPAs requested for the exclusion of PE have a high yield of cardiac abnormalities. Although these abnormalities may not have implications for acute clinical management, they may, nevertheless, be important in long-term care.

  20. Use of cone beam computed tomography in periodontology.

    Science.gov (United States)

    Acar, Buket; Kamburoğlu, Kıvanç

    2014-05-28

    Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimensional periapical and panoramic radiographs are routinely used for diagnosing periodontal bone levels. In two dimensional imaging, evaluation of bone craters, lamina dura and periodontal bone level is limited by projection geometry and superpositions of adjacent anatomical structures. Those limitations of 2D radiographs can be eliminated by three-dimensional imaging techniques such as computed tomography. Cone beam computed tomography (CBCT) generates 3D volumetric images and is also commonly used in dentistry. All CBCT units provide axial, coronal and sagittal multi-planar reconstructed images without magnification. Also, panoramic images without distortion and magnification can be generated with curved planar reformation. CBCT displays 3D images that are necessary for the diagnosis of intra bony defects, furcation involvements and buccal/lingual bone destructions. CBCT applications provide obvious benefits in periodontics, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

  1. Estimation of feline renal volume using computed tomography and ultrasound.

    Science.gov (United States)

    Tyson, Reid; Logsdon, Stacy A; Werre, Stephen R; Daniel, Gregory B

    2013-01-01

    Renal volume estimation is an important parameter for clinical evaluation of kidneys and research applications. A time efficient, repeatable, and accurate method for volume estimation is required. The purpose of this study was to describe the accuracy of ultrasound and computed tomography (CT) for estimating feline renal volume. Standardized ultrasound and CT scans were acquired for kidneys of 12 cadaver cats, in situ. Ultrasound and CT multiplanar reconstructions were used to record renal length measurements that were then used to calculate volume using the prolate ellipsoid formula for volume estimation. In addition, CT studies were reconstructed at 1 mm, 5 mm, and 1 cm, and transferred to a workstation where the renal volume was calculated using the voxel count method (hand drawn regions of interest). The reference standard kidney volume was then determined ex vivo using water displacement with the Archimedes' principle. Ultrasound measurement of renal length accounted for approximately 87% of the variability in renal volume for the study population. The prolate ellipsoid formula exhibited proportional bias and underestimated renal volume by a median of 18.9%. Computed tomography volume estimates using the voxel count method with hand-traced regions of interest provided the most accurate results, with increasing accuracy for smaller voxel sizes in grossly normal kidneys (-10.1 to 0.6%). Findings from this study supported the use of CT and the voxel count method for estimating feline renal volume in future clinical and research studies.

  2. Simulation of computed tomography dose based on voxel phantom

    Science.gov (United States)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  3. Proton Computed Tomography: iterative image reconstruction and dose evaluation

    Science.gov (United States)

    Civinini, C.; Bonanno, D.; Brianzi, M.; Carpinelli, M.; Cirrone, G. A. P.; Cuttone, G.; Lo Presti, D.; Maccioni, G.; Pallotta, S.; Randazzo, N.; Scaringella, M.; Romano, F.; Sipala, V.; Talamonti, C.; Vanzi, E.; Bruzzi, M.

    2017-01-01

    Proton Computed Tomography (pCT) is a medical imaging method with a potential for increasing accuracy of treatment planning and patient positioning in hadron therapy. A pCT system based on a Silicon microstrip tracker and a YAG:Ce crystal calorimeter has been developed within the INFN Prima-RDH collaboration. The prototype has been tested with a 175 MeV proton beam at The Svedberg Laboratory (Uppsala, Sweden) with the aim to reconstruct and characterize a tomographic image. Algebraic iterative reconstruction methods (ART), together with the most likely path formalism, have been used to obtain tomographies of an inhomogeneous phantom to eventually extract density and spatial resolutions. These results will be presented and discussed together with an estimation of the average dose delivered to the phantom and the dependence of the image quality on the dose. Due to the heavy computation load required by the algebraic algorithms the reconstruction programs have been implemented to fully exploit the high calculation parallelism of Graphics Processing Units. An extended field of view pCT system is in an advanced construction stage. This apparatus will be able to reconstruct objects of the size of a human head making possible to characterize this pCT approach in a pre-clinical environment.

  4. Quantitative analysis of cholesteatoma using high resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Shigeru; Yamasoba, Tatsuya (Kameda General Hospital, Chiba (Japan)); Iinuma, Toshitaka

    1992-05-01

    Seventy-three cases of adult cholesteatoma, including 52 cases of pars flaccida type cholesteatoma and 21 of pars tensa type cholesteatoma, were examined using high resolution computed tomography, in both axial (lateral semicircular canal plane) and coronal sections (cochlear, vestibular and antral plane). These cases were classified into two subtypes according to the presence of extension of cholesteatoma into the antrum. Sixty cases of chronic otitis media with central perforation (COM) were also examined as controls. Various locations of the middle ear cavity were measured in terms of size in comparison with pars flaccida type cholesteatoma, pars tensa type cholesteatoma and COM. The width of the attic was significantly larger in both pars flaccida type and pars tensa type cholesteatoma than in COM. With pars flaccida type cholesteatoma there was a significantly larger distance between the malleus and lateral wall of the attic than with COM. In contrast, the distance between the malleus and medial wall of the attic was significantly larger with pars tensa type cholesteatoma than with COM. With cholesteatoma extending into the antrum, regardless of the type of cholesteatoma, there were significantly larger distances than with COM at the following sites: the width and height of the aditus ad antrum, and the width, height and anterior-posterior diameter of the antrum. However, these distances were not significantly different between cholesteatoma without extension into the antrum and COM. The hitherto demonstrated qualitative impressions of bone destruction in cholesteatoma were quantitatively verified in detail using high resolution computed tomography. (author).

  5. Glandular dose in breast computed tomography with synchrotron radiation.

    Science.gov (United States)

    Mettivier, G; Fedon, C; Di Lillo, F; Longo, R; Sarno, A; Tromba, G; Russo, P

    2016-01-21

    The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy). A Geant4 Monte Carlo code was implemented, simulating the photon irradiation from a synchrotron radiation source in the energetic range from 8 to 50 keV with 1 keV intervals, to evaluate the MGD. The code was validated with literature data, in terms of mammographic normalized glandular dose coefficients (DgN) and with ad hoc experimental data, in terms of computed tomography dose index (CTDI). Simulated cylindrical phantoms of different sizes (diameter at phantom base 8, 10, 12, 14 or 16 cm, axial length 1.5 times the radius) and glandular fraction by weight (0%, 14.3%, 25%, 50%, 75% and 100%) were implemented into the code. The validation of the code shows an excellent agreement both with previously published work and in terms of DgN and CDTI measurements. The implemented simulations show a dependence of the glandular dose estimate on the vertical dimension of the irradiated zone when a partial organ irradiation was implemented. Specific normalized coefficients for calculating the MGD to the whole breast or to the single irradiated slice were reported.

  6. Computed tomography findings of early abdominal postoperative complications

    Energy Technology Data Exchange (ETDEWEB)

    Zissin, R.; Osadchy, A. [Sapir Medical Center, Dept. of Diagnostic Imaging, Kfar Saba (Israel)]. E-mail: zisinrivka@clalit.org.il; Gayer, G. [Assaf Harofe Medical Center, Dept. of Diagnostic Imaging, Zrifin (Israel)

    2007-06-15

    Various surgical approaches are used for different abdominal pathological conditions. Postoperative complications occur not infrequently and vary according to the type of the surgery and the clinical context. Nowadays, multidetector computed tomography (MDCT) provides superb anatomic detail and diagnostic accuracy for various intraabdominal pathological processes, even if clinically unsuspected, and it thus has become an essential diagnostic tool for evaluating postoperative insults. Other advantages of abdominal MDCT include its accessibility and its speed, which allow scanning of uncooperative, marginally stable patients. Computed tomography (CT)-guided percutaneous (PC) drainage of postoperative collections is another advantage of CT. Therefore, although CT requires transportation of a critically ill, postoperative patient, it is recommended in any suspicious clinical setting because several conditions require prompt management and a correct diagnosis is crucial. In assessing a patient for suspected postoperative complications, several points should be taken into consideration, including the relevant clinical and laboratory data, the surgical findings, the type of the surgery, the time elapsed since surgery, and the operative technique (either open laparotomy of laparoscopic procedure). (author)

  7. Computed tomography angiography in patients with active gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Fatima Regina Silva; D' Ippolito, Giuseppe, E-mail: fatima.rsreis@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Cardia, P.P. [Hospital Vera Cruz, Campinas, SP (Brazil)

    2015-11-15

    Gastrointestinal bleeding represents a common medical emergency, with considerable morbidity and mortality rates, and a prompt diagnosis is essential for a better prognosis. In such a context, endoscopy is the main diagnostic tool; however, in cases where the gastrointestinal hemorrhage is massive, the exact bleeding site might go undetected. In addition, a trained professional is not always present to perform the procedure. In an emergency setting, optical colonoscopy presents limitations connected with the absence of bowel preparation, so most of the small bowel cannot be assessed. Scintigraphy cannot accurately demonstrate the anatomic location of the bleeding and is not available at emergency settings. The use of capsule endoscopy is inappropriate in the acute setting, particularly in the emergency department at night, and is a highly expensive method. Digital angiography, despite its high sensitivity, is invasive, presents catheterization-related risks, in addition to its low availability at emergency settings. On the other hand, computed tomography angiography is fast, widely available and minimally invasive, emerging as a promising method in the diagnostic algorithm of these patients, being capable of determining the location and cause of bleeding with high accuracy. Based on a critical literature review and on their own experience, the authors propose a computed tomography angiography protocol to assess the patient with gastrointestinal bleeding. (author)

  8. Breast ultrasound computed tomography using waveform inversion with source encoding

    Science.gov (United States)

    Wang, Kun; Matthews, Thomas; Anis, Fatima; Li, Cuiping; Duric, Neb; Anastasio, Mark A.

    2015-03-01

    Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the speed-of-sound distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Computer-simulation studies are conducted to demonstrate the use of the WISE method. Using a single graphics processing unit card, each iteration can be completed within 25 seconds for a 128 × 128 mm2 reconstruction region. The results suggest that the WISE method maintains the high spatial resolution of waveform inversion methods while significantly reducing the computational burden.

  9. Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography/computed tomography.

    Science.gov (United States)

    Rana, Nivedita; Rawat, Dinesh; Parmar, Madan; Dhawan, Devinder Kumar; Bhati, Ashok Kumar; Mittal, Bhagwant Rai

    2015-01-01

    This study was undertaken to evaluate the effect of external metal filters on the image quality of computed tomography (CT) and single photon emission computed tomography (SPECT)/CT images. Images of Jaszack phantom filled with water and containing iodine contrast filled syringes were acquired using CT (120 kV, 2.5 mA) component of SPECT/CT system, ensuring fixation of filter on X-ray collimator. Different thickness of filters of Al and Cu (1 mm, 2 mm, 3 mm, and 4 mm) and filter combinations Cu 1 mm, Cu 2 mm, Cu 3 mm each in combination with Al (1 mm, 2 mm, 3 mm, and 4 mm), respectively, were used. All image sets were visually analyzed for streak artifacts and contrast to noise ratio (CNR) was derived. Similar acquisition was done using Philips CT quality control (QC) phantom and CNR were calculated for its lexan, perspex, and teflon inserts. Attenuation corrected SPECT/CT images of Jaszack phantom filled with 444-555 MBq (12-15 mCi) of (99m)Tc were obtained by applying attenuation correction map generated by hardened X-ray beam for different filter combination, on SPECT data. Uniformity, root mean square (rms) and contrast were calculated in all image sets. Less streak artifacts at iodine water interface were observed in images acquired using external filters as compared to those without a filter. CNR for syringes, spheres, and inserts of Philips CT QC phantom was almost similar to Al 2 mm, Al 3 mm, and without the use of filters. CNR decreased with increasing copper thickness and other filter combinations. Uniformity and rms were lower, and value of contrast was higher for SPECT/CT images when CT was acquired with Al 2 mm and 3 mm filter than for images acquired without a filter. The study suggests that for Infinia Hawkeye 4, SPECT/CT system, Al 2 mm, and 3 mm are the optimum filters for improving image quality of SPECT/CT images of Jaszack or Philips CT QC phantom keeping other parameters of CT constant.

  10. Blunt trauma of bone structures of the chest: Computed tomography vs multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Petrović Kosta

    2013-01-01

    Full Text Available Background/Aim. Computerized tomography (CT, especially multidetector CT (MDCT, has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR. Methods. This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists independently and separately described the findings for 5-mmthick axial CT slices (5 mm CT as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thinslice examination together which was ultimately considered as a real, true finding. Results. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05. Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05 in favor of better display of injury by MDCT examination. Conclusion. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

  11. Massively parallel computers for 3D single-photon-emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Butler, C.S.; Miller, M.I. (Washington Univ., St. Louis, MO (United States). Electronic Systems and Signals Research Lab.); Miller, T.R.; Wallis, J.W. (Washington Univ., St. Louis, MO (United States). Edward Mallinckrodt Inst. of Radiology)

    1994-03-01

    Since the introduction of the expectation-maximization (EM) algorithm for generating maximum-likelihood (ML) and maximum a posteriori (MAP) estimates in emission tomography, there have been many investigators applying the ML method. However, almost all of the previous work has been restricted to two-dimensional (2D) reconstructions. The major focus and contribution of this paper is to demonstrate a fully three-dimensional (3D) implementation of the MAP method for single-photon-emission computed tomography (SPECT). The 3D reconstruction exhibits an improvement in resolution when compared to the generation of the series of separate 2D slice reconstructions. (Author).

  12. Is there a role for the use of volumetric cone beam computed tomography in periodontics?

    Science.gov (United States)

    du Bois, A H; Kardachi, B; Bartold, P M

    2012-03-01

    Volumetric computed cone beam tomography offers a number of significant advantages over conventional intraoral and extraoral panoramic radiography, as well as computed tomography. To date, periodontal diagnosis has relied heavily on the assessment of both intraoral radiographs and extraoral panoramic radiographs. With emerging technology in radiology there has been considerable interest in the role that volumetric cone beam computed tomography might play in periodontal diagnostics. This narrative reviews the current evidence and considers whether there is a role for volumetric cone beam computed tomography in periodontics.

  13. The diagnostic value of indeterminate lung lesions on staging chest computed tomographies in patients with colorectal cancer

    DEFF Research Database (Denmark)

    Christoffersen, Mette Williaume; Bulut, Orhan; Jess, Per

    2010-01-01

    INTRODUCTION: Selection of pulmonary staging modality in colorectal cancer surgery is controversial. Computed tomography (CT) clearly outperforms x-ray in terms of sensitivity, but findings of indeterminate lung lesions remain a problem. The aim of the present study was to evaluate the significance...... indeterminate lung findings. Four died postoperatively. The remaining 22 were followed for a median period of 26 months. RESULTS: In eight of the 22 patients (36%) lesions progressed. In one patient, the lesion turned out to be a primary lung cancer, in another a lymphoma. In the last six patients (27...... tenth into other lung malignancies, which were most often diagnosed in the second year after surgery. The development of lung metastases was significantly related to positive nodal disease and postoperative CEA elevation....

  14. Hypotension associated with advanced Hodgkin lymphoma

    Directory of Open Access Journals (Sweden)

    Ankit Mangla

    2014-09-01

    Full Text Available Hypotension is an extremely rare manifestation of Hodgkin lymphoma. We report the case of a patient who presented with new onset hypotension and was diagnosed with urosepsis and septic shock requiring pressor support for maintaining his blood pressure. computed tomography (CT scan of abdomen showed liver lesions, which were new on comparison with a CT abdomen done 3 weeks back. Biopsy of the liver lesions and subsequently a bone marrow biopsy showed large atypical Reed-Sternberg cells, positive for CD15 and CD 30 and negative for CD45, CD3 and CD20 on immunohistochemical staining, hence establishing the diagnosis of Hodgkin lymphoma. The mechanism involved in Hodgkin lymphoma causing hypotension remains anecdotal, but since it is mostly seen in patients with advanced Hodgkin lymphoma, it is hypothetically related to a complex interaction between cytokines and mediators of vasodilatation. Here we review relevant literature pertaining to presentation and pathogenesis of this elusive and rare association.

  15. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  16. Low Utility of Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography for Detecting Hepatocellular Carcinoma in Patients Before Liver Transplantation.

    Science.gov (United States)

    Alotaibi, Faisal; Kabbani, Monther; Abaalkhail, Faisal; Chorley, Alicia; Elbeshbeshy, Hany; Al-Hamoudi, Waleed; Alabbad, Saleh; Boehnert, Markus U; Alsofayan, Mohammad; Al-Kattan, Wael; Ahmed, Baderaldeen; Broering, Dieter; Al Sebayel, Mohamed; Elsiesy, Hussien

    2017-02-01

    Our program routinely used fluorodeoxyglucose-positron emission tomography/computed tomography as part of the liver transplant evaluation of patients with hepatocellular carcinoma. The aim of this study was to evaluate the role of this imaging modality in the pretransplant work-up. This was a retrospective chart review of our liver transplant database from January 2011 to December 2014 for all patients with hepatocellular carcinoma who underwent a liver transplant. Collected data included age, sex, cause of liver disease, imaging modality, fluorodeoxyglucose-positron emission tomography/computed tomography results, explant tissue analysis, type of transplant, and transplant outcome. During the study period, 275 liver transplants were performed. Fifty-three patients had hepatocellular carcinoma; 41 underwent fluorodeoxyglucose-positron emission tomography/computed tomography. Twenty-nine patients underwent living-donor liver transplant, and 12 patients underwent deceased-donor liver transplant. One of the 41 patients with negative FDG-imaging results had no evidence of hepatocellular carcinoma in the explant and was excluded from the study. The patients' average age was 58 years (range, 22-72 y), and 28 patients were men. The cause of liver disease was hepatitis C virus in 24 patients, cryptogenic cirrhosis in 12 patients, and hepatitis B virus in 5 patients. One patient had no hepatocellular carcinoma on explants and was excluded from the study. Twenty-five patients had hepatocellular carcinoma that met the Milan criteria, 7 were within the UCSF (University of California, San Francisco) criteria, and 8 exceeded the UCSF criteria. Of the 40 patients, 11 had positive fluorodeoxyglucose-positron emission tomography/computed tomography results (27.5%) with evidence of hepatocellular carcinoma in the explant; the remaining 29 patients (72.5%) had negative results. The fluorodeoxyglucose-positron emission tomography/computed tomography results were positive in 16% (4 of

  17. Simulation of emission tomography using grid middleware for distributed computing.

    Science.gov (United States)

    Thomason, M G; Longton, R F; Gregor, J; Smith, G T; Hutson, R K

    2004-09-01

    SimSET is Monte Carlo simulation software for emission tomography. This paper describes a simple but effective scheme for parallel execution of SimSET using NetSolve, a client-server system for distributed computation. NetSolve (version 1.4.1) is "grid middleware" which enables a user (the client) to run specific computations remotely and simultaneously on a grid of networked computers (the servers). Since the servers do not have to be identical machines, computation may take place in a heterogeneous environment. To take advantage of diversity in machines and their workloads, a client-side scheduler was implemented for the Monte Carlo simulation. The scheduler partitions the total decay events by taking into account the inherent compute-speeds and recent average workloads, i.e., the scheduler assigns more decay events to processors expected to give faster service and fewer decay events to those expected to give slower service. When compute-speeds and sustained workloads are taken into account, the speed-up is essentially linear in the number of equivalent "maximum-service" processors. One modification in the SimSET code (version 2.6.2.3) was made to ensure that the total number of decay events specified by the user is maintained in the distributed simulation. No other modifications in the standard SimSET code were made. Each processor runs complete SimSET code for its assignment of decay events, independently of others running simultaneously. Empirical results are reported for simulation of a clinical-quality lung perfusion study.

  18. Hodgkin's Lymphoma

    Science.gov (United States)

    ... behavior. Your type determines your treatment options. Classical Hodgkin's lymphoma Classical Hodgkin's lymphoma is the more common ... Hodgkin's lymphoma Lymphocyte-rich Hodgkin's lymphoma Lymphocyte-predominant Hodgkin's lymphoma This much rarer type of Hodgkin's lymphoma ...

  19. Computed tomography image reconstruction from only two projections

    CERN Document Server

    Mohammad-Djafari, Ali

    2007-01-01

    English: This paper concerns the image reconstruction from a few projections in Computed Tomography (CT). The main objective of this paper is to show that the problem is so ill posed that no classical method, such as analytical methods based on inverse Radon transform, nor the algebraic methods such as Least squares (LS) or regularization theory can give satisfactory result. As an example, we consider in detail the case of image reconstruction from two horizontal and vertical projections. We then show how a particular composite Markov modeling and the Bayesian estimation framework can possibly propose satisfactory solutions to the problem. For demonstration and educational purpose a set of Matlab programs are given for a live presentation of the results. ----- French: Ce travail, \\`a but p\\'edagogique, pr\\'esente le probl\\`eme inverse de la reconstruction d'image en tomographie X lorsque le nombre des projections est tr\\`es limit\\'e. voir le texte en Anglais et en Fran\\c{c}ais.

  20. Quantifying the debonding of inclusions through tomography and computational homology.

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Yang; Johnson, George C. (University of California, Berkeley, Berkeley, CA); Mota, Alejandro; Foulk, James W., III; Jin, Huiqing

    2010-09-01

    This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

  1. How does PET/CT help in selecting therapy for patients with Hodgkin lymphoma?

    DEFF Research Database (Denmark)

    Hutchings, Martin

    2012-01-01

    Positron emission tomography/computed tomography (PET/CT) has emerged as the most accurate tool for staging, treatment monitoring, and response evaluation in Hodgkin lymphoma (HL). Accurate staging and restaging are very important for the optimal management of HL, but we are only beginning...

  2. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  3. Virtual positron emission tomography/computed tomography-bronchoscopy: possibilities, advantages and limitations of clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Seemann, Marcus D. [University of Magdeburg, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Schaefer, Juergen F. [Eberhard-Karls University, Department of Diagnostic Radiology, Tuebingen (Germany); Englmeier, Karl-Hans [Institute of Medical Informatics, GSF-National Research Center for Environment and Health, Neuherberg (Germany)

    2007-03-15

    The aim of this study was to demonstrate the possibilities, advantages and limitations of virtual bronchoscopy using data sets from positron emission tomography (PET) and computed tomography (CT). Twelve consecutive patients with lung cancer underwent PET/CT. PET was performed with F-18-labelled 2-[fluorine-18]-fluoro-2-deoxy-D-glucose ({sup 18}F-FDG). The tracheobronchial system was segmented with a volume-growing algorithm, using the CT data sets, and visualized with a shaded-surface rendering method. The primary tumours and the lymph node metastases were segmented for virtual CT-bronchoscopy using the CT data set and for virtual PET/CT-bronchoscopy using the PET/CT data set. Virtual CT-bronchoscopy using the low-dose or diagnostic CT facilitates the detection of anatomical/morphological structure changes of the tracheobronchial system. Virtual PET/CT-bronchoscopy was superior to virtual CT-bronchoscopy in the detection of lymph node metastases (P=0.001), because it uses the CT information and the molecular/metabolic information from PET. Virtual PET/CT-bronchoscopy with a transparent colour-coded shaded-surface rendering model is expected to improve the diagnostic accuracy of identification and characterization of malignancies, assessment of tumour staging, differentiation of viable tumour tissue from atelectases and scars, verification of infections, evaluation of therapeutic response and detection of an early stage of recurrence that is not detectable or is misjudged in comparison with virtual CT-bronchoscopy. (orig.)

  4. Small-Animal Imaging Using Clinical Positron Emission Tomography/Computed Tomography and Super-Resolution

    Directory of Open Access Journals (Sweden)

    Frank P. DiFilippo

    2012-05-01

    Full Text Available Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT, an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling were investigated. National Electrical Manufacturers Association (NEMA NU 4 phantom and mouse data were acquired with a clinical PET/CT scanner, as both conventional static and stepped scans. Static scans were reconstructed with and without point spread function (PSF modeling. Stepped images were postprocessed with iterative deconvolution to produce super-resolution images. Image quality was markedly improved using the super-resolution technique, avoiding certain artifacts produced by PSF modeling. The 2 mm rod of the NU 4 phantom was visualized with high contrast, and the major structures of the mouse were well resolved. Although not a perfect substitute for a state-of-the-art small-animal PET/CT scanner, a clinical PET/CT scanner with super-resolution produces acceptable small-animal image quality for many preclinical research studies.

  5. Positron emission tomography/computer tomography in guidance of extrahepatic hepatocellular carcinoma metastasis management

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Hepatocellular carcinoma (HCC) is one of the most common primary cancers in the world. Surgery is the gold standard for treatment of patients with HCC. Recurrence and metastasis are the major obstacles to further improve the prognosis of HCC. Most recurrences are intrahepatic. However, 30% of the recurrences are extrahepatic. The role of resection in intrahepatic recurrences is widely accepted. The role of resection in extrahepatic HCC recurrence and metastasis is not well established. 18F fluorodeoxyglucose (18F-FDG) positron emission tomography/computer tomography (PET/CT) is useful in detecting distant metastasis from a variety of malignancies and shows superior accuracy to conventional imaging modalities in identification of intrahepatic and extrahepatic metastasis. We present one patient with one new isolated omental lymph node metastasis, who had a history of huge HCC resected six years ago. The metastatic focus was identified with 18 F-FDG PET/CT and resected. The follow-up revealed good prognosis with a long-term survival potential after resection of the omental lymphatic metastasis.

  6. Cone beam computed tomography: A boon for maxillofacial imaging

    Directory of Open Access Journals (Sweden)

    Sreenivas Rao Ghali

    2017-01-01

    Full Text Available In day to day practice, the radiographic techniques used individually or in combination suffer from some inherent limits of all planar two-dimensional (2D projections such as magnification, distortion, superimposition, and misrepresentation of anatomic structures. The introduction of cone-beam computed tomography (CBCT, specifically dedicated to imaging the maxillofacial region, heralds a major shift from 2D to three-dimensional (3D approach. It provides a complete 3D view of the maxilla, mandible, teeth, and supporting structures with relatively high resolution allowing a more accurate diagnosis, treatment planning and monitoring, and analysis of outcomes than conventional 2D images, along with low radiation exposure to the patient. CBCT has opened up new vistas for the use of 3D imaging as a diagnostic and treatment planning tool in dentistry. This paper provides an overview of the imaging principles, underlying technology, dental applications, and in particular focuses on the emerging role of CBCT in dentistry.

  7. Lung cancer screening: Computed tomography or chest radiographs?

    Institute of Scientific and Technical Information of China (English)

    Edwin; JR; van; Beek; Saeed; Mirsadraee; John; T; Murchison

    2015-01-01

    Worldwide, lung cancer is the leading cause of mortalitydue to malignancy. The vast majority of cases of lung cancer are smoking related and the most effective way of reducing lung cancer incidence and mortality is by smoking cessation. In the Western world, smoking cessation policies have met with limited success. The other major means of reducing lung cancer deaths is to diagnose cases at an earlier more treatable stage employing screening programmes using chest radiographs or low dose computed tomography. In many countries smoking is still on the increase, and the sheer scale of the problem limits the affordability of such screening programmes. This short review article will evaluate the current evidence and potential areas of research which may benefit policy making across the world.

  8. Survey of patient dose in computed tomography in Syria 2009.

    Science.gov (United States)

    Kharita, M H; Khazzam, S

    2010-09-01

    The radiation doses to patient in computed tomography (CT) in Syria have been investigated and compared with similar studies in different countries. This work surveyed 30 CT scanners from six different manufacturers distributed all over Syria. Some of the results in this paper were part of a project launched by the International Atomic Energy Agency in different regions of the world covering Asia, Africa and Eastern Europe. The dose quantities covered are CT dose index (CTDI(w)), dose-length product (DLP), effective dose (E) and collective dose. It was found that most CTDI(w) and DLP values were similar to the European reference levels and in line with the results of similar surveys in the world. The results were in good agreement with the UNSCEAR Report 2007. This study concluded a recommendation for national diagnostic reference level for the most common CT protocols in Syria. The results can be used as a base for future optimisation studies in the country.

  9. Micro-computed tomography for small animal imaging: Technological details

    Institute of Scientific and Technical Information of China (English)

    Hao Li; Hui Zhang; Zhiwei Tang; Guangshu Hu

    2008-01-01

    The high-resolution micro-computed tomography(micro-CT)system has now become an important tool for biological research.The micro-CT system enables a non-invasive inspection to screen anatomical changes in small animals.The promising advantages include high-spatial resolution,high sensitivity to bone and lung,short scan time and cost-effectiveness.The dose received by the small animal might be a critical concern in the research.In this article,the choice of the components,fundamental physical problems,the image reconstruction algorithm and the representative applications of micro-CT are summarized.Some results from our research group are also presented to show high-resolution images obtained by the micro-CT system.

  10. Experimental determination of the segregation process using computer tomography

    Directory of Open Access Journals (Sweden)

    Konstantin Beckmann

    2016-07-01

    Full Text Available Modelling methods such as DEM and CFD are increasingly used for developing high efficient combine cleaning systems. For this purpose it is necessary to verify the complex segregation and separation processes in the combine cleaning system. One way is to determine the segregation and separation function using 3D computer tomography (CT. This method makes it possible to visualize and analyse the movement behaviour of the components of the mixture during the segregation and separation process as well as the derivation of descriptive process parameters. A mechanically excited miniature test rig was designed and built at the company CLAAS Selbstfahrende Erntemaschinen GmbH to achieve this aim. The investigations were carried out at the Fraunhofer Institute for Integrated Circuits IIS. Through the evaluation of the recorded images the segregation process is described visually. A more detailed analysis enabled the development of segregation and separation function based on the different densities of grain and material other than grain.

  11. Temporal bone trauma and complications: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Ana Maria Doffemond; Gaiotti, Juliana Oggioni; Couto, Caroline Laurita Batista; Gomes, Natalia Delage; Diniz, Renata Lopes Furletti Caldeira; Motta, Emilia Guerra Pinto Coelho, E-mail: anadoffemond@yahoo.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unit of Radiology and Imaging Diagnosis

    2013-03-15

    Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others. (author)

  12. Malignant uveal melanoma and similar lesions studied by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mafee, M.F.; Peyman, G.A.; McKusick, M.A.

    1985-08-01

    Forty-four patients with intraocular disease were studied by computed tomography (CT); in 19 cases malignant uveal melanoma was considered the likely diagnosis. CT proved to be accurate in determining the location and size of uveal melanomas, demonstrating scleral invasion, and differentiating melanoma from choroidal detachment or angioma, toxocariasis, and senile macular degeneration. On CT, uveal melanomas appeared as hyperdense lesions with slight to moderate contrast enhancement. Tumors thinner than 2 mm could not be seen. Using dynamic CT, the authors noted moderate peak amplitude, normal or delayed tissue transit time, and persistently elevated washout phase (downslope), indicating increased permeability as the result of an impaired tumor blood barrier. Histological types of uveal melanoma could not be differentiated on the basis of circulatory patterns. Dynamic CT may be useful in distinguishing uveal melanoma from choroidal hemangioma or hematoma.

  13. [Vascular assessment in stroke codes: role of computed tomography angiography].

    Science.gov (United States)

    Mendigaña Ramos, M; Cabada Giadas, T

    2015-01-01

    Advances in imaging studies for acute ischemic stroke are largely due to the development of new efficacious treatments carried out in the acute phase. Together with computed tomography (CT) perfusion studies, CT angiography facilitates the selection of patients who are likely to benefit from appropriate early treatment. CT angiography plays an important role in the workup for acute ischemic stroke because it makes it possible to confirm vascular occlusion, assess the collateral circulation, and obtain an arterial map that is very useful for planning endovascular treatment. In this review about CT angiography, we discuss the main technical characteristics, emphasizing the usefulness of the technique in making the right diagnosis and improving treatment strategies. Copyright © 2012 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  14. Experimental determination of the segregation process using computer tomography

    Directory of Open Access Journals (Sweden)

    Konstantin Beckmann

    2016-08-01

    Full Text Available Modelling methods such as DEM and CFD are increasingly used for developing high efficient combine cleaning systems. For this purpose it is necessary to verify the complex segregation and separation processes in the combine cleaning system. One way is to determine the segregation and separation function using 3D computer tomography (CT. This method makes it possible to visualize and analyse the movement behaviour of the components of the mixture during the segregation and separation process as well as the derivation of descriptive process parameters. A mechanically excited miniature test rig was designed and built at the company CLAAS Selbstfahrende Erntemaschinen GmbH to achieve this aim. The investigations were carried out at the Fraunhofer Institute for Integrated Circuits IIS. Through the evaluation of the recorded images the segregation process is described visually. A more detailed analysis enabled the development of segregation and separation function based on the different densities of grain and material other than grain.

  15. Dimensional measurement of micro-moulded parts by computed tomography

    DEFF Research Database (Denmark)

    Ontiveros, S.; Yagüe-Fabra, J.A.; Jiménez, R.

    2012-01-01

    Computed tomography (CT) is progressively assuming an important role in metrology applications and great efforts are being made in order to turn it into a reliable and standardized measuring technology. CT is typically used for non-destructive tests, but it is currently becoming very popular...... for dimensional metrology applications due to its strategic advantages such as the capability of performing measurements on both the component's surface and volume, allowing inspection possibilities to otherwise non-accessible internal features. This paper focuses on the dimensional verification of two micro......-injection moulded components, selected from actual industrial productions, using CT metrological tools. For this purpose, several parts have been measured with two different CT machines, and the results have been compared with the measurements obtained by other measuring systems. The experimental work carried out...

  16. Cysticercosis of the brain. The value of computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almeida-Pinto, J.; Veiga-Pires, J.A.; Stocker, A.; Coelho, T.; Monteiro, L.

    Incidence and radiologic findings of neurocysticercosis were investigated in a series of 23 800 consecutive head examinations using computed tomography (CT). The condition was diagnosed in 168 case (0.7%). The parenchymatous form was the most common presentation (96.3%), while the meningeal form corresponded to only 11.9% of cases. These two forms coexisted in some cases. These findings reversed the knowledge on the condition based on conventional radiography. The different CT appearances in the brain are described and a new radiologic protocol for the CT evaluation of the condition is advocated, which includes a follow-up after a trial cure with Praziquantel in the presence of cysts not associated with suggestive brain calcifications. CT were more sensitive than conventional radiography in the differentiation between dead and living larvae, thus having an impact on the therapeutic management of the patients.

  17. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Atzingen, Augusto Castelli von [Clinical Radiology, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Tiferes, Dario Ariel; Matsumoto, Carlos Alberto; Nunes, Thiago Franchi; Maia, Marcos Vinicius Alvim Soares [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil)

    2012-05-15

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensional renderings, with sensitivity around 96% in the detection of lesions with dimensions equal or greater than 10 mm in size, when analyzed by experienced radiologists. The present pictorial essay includes examples of diseases and pseudolesions most frequently observed in this type of imaging study. The authors present examples of flat and polypoid lesions, benign and malignant lesions, diverticular disease of the colon, among other conditions, as well as pseudolesions, including those related to inappropriate bowel preparation and misinterpretation. (author)

  18. Use and impact of positron computed tomography scanning in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Mazziotta, J.C.; Engel, J. Jr.

    1984-01-01

    Through the effective combination of instrumentation, tracer kinetic principles, and radiopharmaceuticals, positron computed tomography (PET) allows for the analytic, noninvasive measurement of local tissue physiology in humans. A large number of studies have already been performed in patients with epilepsy using 18F-fluorodeoxyglucose (FDG) to measure local cerebral glucose utilization. In patients with complex partial epilepsy who are candidates for surgery, hypometabolic zones have been seen consistently (70%) in the interictal state. The complex anatomical and pathophysiological investigation of these hypometabolic zones is discussed. Ictal studies of patients with partial seizures have demonstrated a much more variable metabolic pattern which usually consists of hypermetabolism relative to baseline or interictal studies. Generalized epilepsy produced by electroconvulsive shock and petit mal epilepsy have been studied using FDG to estimate glucose metabolism.

  19. Meningitis tuberculosa: Clinical findings and results of cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Trautmann, M.; Loddenkemper, R.; Hoffmann, H.G.

    1982-10-01

    Guided by 9 own observations between 1977 and 1981, new diagnostic facilities in tuberculous meningitis are discussed. For differentiation from viral meningitis, measurement of CSF lactic acid concentration in addition to that of CSF glucose has proved to be of value in recent years. In accordance with the literature, two cases of this series which were examined for CSF lactic acid concentration showed markedly elevated levels of 8,4 rsp. 10,4 mmol/l. In contrast to this, in viral meningitis usually values of less than 3.5 mmol/l are found. Additionally, the presence of hypochlor- and hyponatremia, which could be demonstrated in 6 of our 9 patients, may raise the suspicion of tuberculous etiology. In the series presented, cranial computed tomography was of greatest diagnostic value, enabling the diagnosis of hydrocephalus internus in 5, and basal arachnoiditis in 2 cases.

  20. Three-dimensional computed tomography of the acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, R.S.; Muner, G.; Pozzi Mucelli, F.; Pozzi Mucelli, M.; Marotti, F.; Dalla Palma, L.

    1986-08-01

    Acetabular fractures represent a complex variety that are classified in different types. Conventional radiology is often inadequate to demonstrate and classify the fractures. Computed tomography (CT) has already been shown to be superior in this field. A further advantage of CT is represented by the recent availability of three-dimensional (3D) images that are realized from axial CT scans by means of a new software. The Authors report the applications of this new software to the study of the normal acetabulum and in patients with fractures. 3D images allows an effective demonstration of the fracture, its irradiation and the dislocation of bone fragments. The information is contained in one or few images rather than many axial images. Therefore the role of 3D images may be considered complementary to axial CT scans.

  1. Non-diffusing photochromic gel for optical computed tomography phantoms

    Science.gov (United States)

    Jordan, K.

    2013-06-01

    This study examines photochromic response in radiation sensitive hydrogels. Genipin, crosslinked, gelatin gel can support high resolution images because the chromophores do not diffuse. A low power, 633 nm He-Ne laser was used to write lines into the gels by a photobleaching reaction. Optical cone-beam computed tomography (CBCT) scans mapped the high resolution images in 3D with 0.25 mm voxel resolution. A straight line was written into a deformed gel and then readout in its relaxed, initial shape. The curved, photo-bleached line demonstrated deformable 3D dosimetry is possible with this system to the balloon edge. High resolution, photochromic images provide key information for characterizing optical CT scanners and 3D dosimeters. Many, ionizing radiation, dosimeter materials demonstrate either a photochromic or photothermal response, allowing this approach to be widely used in quantitative 3D scanning.

  2. Glasses for 3D ultrasound computer tomography: phase compensation

    Science.gov (United States)

    Zapf, M.; Hopp, T.; Ruiter, N. V.

    2016-03-01

    Ultrasound Computer Tomography (USCT), developed at KIT, is a promising new imaging system for breast cancer diagnosis, and was successfully tested in a pilot study. The 3D USCT II prototype consists of several hundreds of ultrasound (US) transducers on a semi-ellipsoidal aperture. Spherical waves are sequentially emitted by individual transducers and received in parallel by many transducers. Reflectivity volumes are reconstructed by synthetic aperture focusing (SAFT). However, straight forward SAFT imaging leads to blurred images due to system imperfections. We present an extension of a previously proposed approach to enhance the images. This approach includes additional a priori information and system characteristics. Now spatial phase compensation was included. The approach was evaluated with a simulation and clinical data sets. An increase in the image quality was observed and quantitatively measured by SNR and other metrics.

  3. Fossa navicularis magna detection on cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Syed, Ali Z. [Dept. of Oral and Maxillofacial Medicine and Diagnostic Sciences, School of Dental Medicine, Case Western Reserve University, Cleveland(United States); Mupparapu, Mel [Div. of Radiology, University of Pennsylvania School of Dental Medicine, Philadelphia (United States)

    2016-03-15

    Herein, we report and discuss the detection of fossa navicularis magna, a close radiographic anatomic variant of canalis basilaris medianus of the basiocciput, as an incidental finding in cone-beam computed tomography (CBCT) imaging. The CBCT data of the patients in question were referred for the evaluation of implant sites and to rule out pathology in the maxilla and mandible. CBCT analysis showed osseous, notch-like defects on the inferior aspect of the clivus in all four cases. The appearance of fossa navicularis magna varied among the cases. In some, it was completely within the basiocciput and mimicked a small rounded, corticated, lytic defect, whereas it appeared as a notch in others. Fossa navicularis magna is an anatomical variant that occurs on the inferior aspect of the clivus. The pertinent literature on the anatomical variations occurring in this region was reviewed.

  4. Computed tomography of the oropharynx in obstructive sleep apnea

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, S.G.; Gislason, T.; Lindholm, C.E.

    Computed tomography (CT) of the oropharynx was obtained in 32 consecutive adult patients with proven OSAS. An additional 15 patients with the same complaints, but without objective evidence of OSAS, were used as a control group, together with 20 normal subjects. The axial widths of the tongue and the genioglossus and hyoglossus muscles were measured by CT. Both the tongue and genioglossus widths were significantly larger in the OSAS patients than in the two control groups (p < 0.001). The increased tongue width will cause encroachment of the oropharyngeal airway below the level of the soft palate. Thus, CT can be used to measure the tongue size in order to evaluate its predictive value for the outcome of the UPPP procedure.

  5. Computed tomography using broadband Bessel THz beams and phase contrast.

    Science.gov (United States)

    Bitman, Assaf; Goldring, Sharone; Moshe, Inon; Zalevsky, Zeev

    2014-04-01

    We present new results demonstrating the capability of performing computed tomography (CT) using broadband Bessel terahertz (THz) beams. Nondiffractive beams such as these exhibit propagation-invariant lines of focus with an extended depth-of-field compared to conventional Gaussian beams. Using this property, we demonstrate a considerable improvement in the 3D reconstruction image of a synthetic sample through the backprojection algorithm. Only when THz Bessel beams are used, a full reconstruction of the object structure is made. Moreover, we use phase-contrast mechanism which improves the spatial resolution and reconstructed images. Our results highlight the potential in using nondiffractive Bessel beams to significantly improve 3D-image reconstruction of THz CT.

  6. Computed tomography of deep fat masses in multiple symmetrical lipomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Enzi, G.; Biondetti, P.R.; Fiore, D.; Mazzoleni, F.

    1982-07-01

    Deep fat masses were evaluated by computed tomography (CT) in 15 patients with multiple symmetrical lipomatosis. In 4 patients, peritracheal accumulations of fat were observed. In 3 of them, tracheal compression by lipomatous tissue was demonstrated: 2 were asymptomatic and the third severe respiratory insufficiency secondary to blockage of the air was by the vocal cords as the result of recurrent nerve palsy. In 6 patients, lipomatous tissue occupied the potential space between the spina scapulae and the trapezius, supraspinatus, and infraspinatus muscles. In 2, calcification of lipomatous masses was observed. There was no relationship between extension of subcutaneous fat and accumulation at deep sites. CT facilitates early detection of peritracheal lipomatous tissue and is helpful in follow-up when deep fat accumulation is responsible for space-occupying lesions requiring surgery.

  7. Dose reduction with adaptive bolus chasing computed tomography angiography.

    Science.gov (United States)

    Cai, Zhijun; Bai, Er-Wei; Wang, Ge; Sharafuddin, Melhem J; Abada, Hicham T

    2010-01-01

    Computed Tomography (CT) has become an effective diagnosis and evaluating tool in clinical; however, its radiation exposure has drawn great attention as more and more CT scans are performed every year. How to reduce the radiation dose and meanwhile keep the resultant CT images diagnosable becomes an important research topic. In this paper, we propose a dose reduction approach along with the adaptive bolus chasing CT Angiography (CTA) techniques, which are capable of tracking the contrast bolus peak over all the blood vessel segments during the CTA scan. By modulating the tube current (and collimator width) online, we can reduce the total radiation dose and maintain the contrast to noise ratio (CNR) of the blood vessel. Numerical experiments on reference DSA data sets show that by using the proposed dose reduction method, the effective radiation dose can be saved about 39%.

  8. Inspection of a Medieval Wood Sculpture Using Computer Tomography

    Science.gov (United States)

    Kapitany, K.; Somogyi, A.; Barsi, A.

    2016-06-01

    Computer tomography (CT) is an excellent technique for obtaining accurate 3D information about the human body. It allows to visualize the organs, bones and blood vessels, furthermore it enables to diagnose anomalies and diseases. Its spatial reconstruction capability supports other interesting applications, such as inspecting different, even valuable objects like ancient sculptures. Current paper presents a methodology of evaluating CT and video imagery through the example of investigating a wood Madonna with infant Jesus sculpture from the 14th century. The developed techniques extract the outer boundary of the statue, which has been triangulated to derive the surface model. The interior of the sculpture has also been revealed: the iron bolts and rivets as well as the woodworm holes can be mapped. By merging the interior and outer data (geometry and texture) interesting visualizations (perspective views, sections etc.) have been created.

  9. Software innovations in computed tomography for structural heart disease interventions.

    Science.gov (United States)

    Hell, Michaela; Marwan, Mohamed; Gaede, Luise; Achenbach, Stephan

    2016-05-17

    Computed tomography (CT) provides high, isotropic spatial resolution and has become firmly established in pre-procedural imaging for structural heart disease interventions. It allows determination of the exact dimensions of the target structure, provides information regarding the access route and permits identification of fluoroscopic projection angles to provide optimal visualisation for device placement. Several software solutions are available and have been systematically evaluated in the context of transcatheter aortic valve implantation (TAVI). The use of software products to perform automated measurements can be useful, especially when the experience and expertise regarding evaluation of CT in the context of structural heart disease are limited. In scientific studies, software has been demonstrated to provide accurate support for annulus sizing and prosthesis selection, to aid in reliably identifying patients in whom a transfemoral access may be problematic, and to suggest suitable angulations for fluoroscopic imaging to achieve an orthogonal view onto the aortic valve during implantation.

  10. Brain perfusion: computed tomography and magnetic resonance techniques.

    Science.gov (United States)

    Copen, William A; Lev, Michael H; Rapalino, Otto

    2016-01-01

    Cerebral perfusion imaging provides assessment of regional microvascular hemodynamics in the living brain, enabling in vivo measurement of a variety of different hemodynamic parameters. Perfusion imaging techniques that are used in the clinical setting usually rely upon X-ray computed tomography (CT) or magnetic resonance imaging (MRI). This chapter reviews CT- and MRI-based perfusion imaging techniques, with attention to image acquisition, clinically relevant aspects of image postprocessing, and fundamental differences between CT- and MRI-based techniques. Correlations with cerebrovascular physiology and potential clinical applications of perfusion imaging are reviewed, focusing upon the two major classes of neurologic disease in which perfusion imaging is most often performed: primary perfusion disorders (including ischemic stroke, transient ischemic attack, and reperfusion syndrome), and brain tumors. © 2016 Elsevier B.V. All rights reserved.

  11. Quantitative Pulmonary Imaging Using Computed Tomography and Magnetic Resonance Imaging

    Science.gov (United States)

    Washko, George R.; Parraga, Grace; Coxson, Harvey O.

    2011-01-01

    Measurements of lung function, including spirometry and body plethesmography, are easy to perform and are the current clinical standard for assessing disease severity. However, these lung functional techniques do not adequately explain the observed variability in clinical manifestations of disease and offer little insight into the relationship of lung structure and function. Lung imaging and the image based assessment of lung disease has matured to the extent that it is common for clinical, epidemiologic, and genetic investigation to have a component dedicated to image analysis. There are several exciting imaging modalities currently being used for the non-invasive study of lung anatomy and function. In this review we will focus on two of them, x-ray computed tomography and magnetic resonance imaging. Following a brief introduction of each method we detail some of the most recent work being done to characterize smoking-related lung disease and the clinical applications of such knowledge. PMID:22142490

  12. Clinicopathological characteristics and computed tomography features of mucinous gastric carcinoma.

    Science.gov (United States)

    Yan, C; Zhu, Z-G; Yan, M; Zhang, H; Pan, Z-L; Chen, J; Xiang, M; Chen, M-M; Liu, B-Y; Lin, Y-Z

    2011-01-01

    This study investigated the clinicopathological characteristics of mucinous gastric carcinoma (MGC) and assessed whether multidetector-row computed tomography (MDCT) could differentiate MGC from non-mucinous gastric carcinoma (NGC). Clinicopathological data from 542 patients with gastric carcinoma (23 MGC, 519 NGC), who underwent pre-operative MDCT examination and curative or palliative gastrectomy, were analysed. Only seven of the 23 patients with MGC were correctly diagnosed pre-operatively by endoscopic biopsy. The MGC patients had larger tumours, a higher frequency of lymph node metastases, were more likely to have tumours of tumour, node, metastasis stages III and IV, and were less likely to have a curative resection than NGC patients. In addition, five MGC patients had calcifications in the thickened gastric wall. In conclusion, MGC is rare and is detected mostly at an advanced stage. The diagnostic sensitivity of MGC by endoscopic biopsy was relatively low, whereas MDCT was helpful in distinguishing MGC from NGC.

  13. The possibilities of computer tomography in paecilomycosis of lungs

    Directory of Open Access Journals (Sweden)

    Abdusalom Ashurov

    2010-09-01

    Full Text Available We have analyzed computed tomography (CT results of chest in 56 patients with lung injures caused by paecilomycosis fungus at the age from 17 to 59 years. In our investigations, the perverted lung pattern due to pathology of interstitial tissue was observed in 52 (93% patients of 56 (with chronic bronchitis - 100%, exogenous-allergic alveolitis - 93%, recurrent pneumonia - 100% and with bronchial asthma - 80%. Analysis showed that CT provides wide opportunities in visualization of all spectrum of symptoms in lung tissue injury and could allow to increase the accuracy of determining the character and degree of injury, and also it could allow to determine localization and spreading of the pathological process.

  14. Gamma-ray computed tomography to characterize soil surface sealing

    Energy Technology Data Exchange (ETDEWEB)

    Pires, L.F.Luiz F. E-mail: lfpires@cena.usp.br; Macedo, Jose R. de; Souza, Manoel D. de; Bacchi, Osny O.S.; Reichardt, Klaus

    2002-09-01

    The application of sewage sludge as a fertilizer on soils may cause compacted surface layers (surface sealing), which can promote changes on soil physical properties. The objective of this work was to study the use of gamma-ray computed tomography, as a diagnostic tool for the evaluation of this sealing process through the measurement of soil bulk density distribution of the soil surface layer of samples subjected to sewage sludge application. Tomographic images were taken with a first generation tomograph with a resolution of 1 mm. The image analysis opened the possibility to obtain soil bulk density profiles and average soil bulk densities of the surface layer and to detect the presence of soil surface sealing. The sealing crust thickness was estimated to be in the range of 2-4 mm.

  15. Degeneration in dysplastic hips. A computer tomography study

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Rømer, Lone; Søballe, Kjeld

    2005-01-01

    BACKGROUND: Hip dysplasia is considered pre-osteoarthritic, causing degeneration in young individuals. OBJECTIVE: To determine the pattern of degenerative change in moderate to severely dysplastic hips in young patients. DESIGN AND PATIENTS: One hundred and ninety-three consecutively......-referred younger patients with hip pain believed to be caused by hip dysplasia constituted the study cohort. The average age was 35.5 years (range, 15-61 years). They were examined by close-cut transverse pelvic and knee computed tomography and antero-posterior radiographs (CT). We identified 197 hips...... with moderate to severe dysplasia, and 78 hips with normal morphology in the study cohort, whilst 111 hip joints were borderline dysplastic according to preset definitions. Comparative analyses of anatomy and distribution of degeneration between dysplastic and normal hips in the study cohort were performed...

  16. Initial results of finger imaging using Photoacoustic Computed Tomography

    CERN Document Server

    van Es, Peter; Moens, Hein J Bernelot; Steenbergen, Wiendelt; Manohar, Srirang

    2014-01-01

    We present a photoacoustic computed tomography investigation on a healthy human finger, to image blood vessels with a focus on vascularity across the interphalangeal joints. The cross-sectional images were acquired using an imager specifically developed for this purpose. The images show rich detail of the digital blood vessels with diameters between 100 $\\mu$m and 1.5 mm in various orientations and at various depths. Different vascular layers in the skin including the subpapillary plexus could also be visualized. Acoustic reflections on the finger bone of photoacoustic signals from skin were visible in sequential slice images along the finger except at the location of the joint gaps. Not unexpectedly, the healthy synovial membrane at the joint gaps was not detected due to its small size and normal vascularization. Future research will concentrate on studying digits afflicted with rheumatoid arthritis to detect the inflamed synovium with its heightened vascularization, whose characteristics are potential marke...

  17. Dacryocystography using computed tomography prior to external dacryocystorhinostomy

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ikue; Chijiiwa, Taeko [National Kyushu Medical Center, Fukuoka (Japan)

    2002-01-01

    We performed dacryocystography using computed tomography in 47 eyes of 45 patients of chronic dacryocystitis prior to external dacryocystorhinostomy. The radiopaque agent was injected into the lower canaliculus. The findings were useful in estimating the thickness of the bony wall of lacrimal fossa. The ethmoidal sinus was located adjacent and nasal to the lacrimal fossa in 11 eyes (23%). Care was needed in these cases not to create an anastomosis between the lacrimal sac and the ethmoidal sinus. The contrast medium was located in the nasolacrimal duct in 14 eyes (30%), suggesting that the obstruction was located in the lower nasolacrimal duct. Intraoperative irrigation-aspiration appeared to be indicated in these cases. Traumatic bony fracture with hypertrophy was present in one case, suggesting that nasolacrimal obstruction may be induced by facial trauma. (author)

  18. Quality Criteria Implementation for Brain Computed Tomography Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Calzado, A.; Rodriguez, R.; Munoz, A

    1998-07-01

    The main aim of this study was to implement the quality criteria proposed by the European Commission for brain computed tomography (CT) examinations. The proposed criteria were evaluated for 102 brain CT examinations, with a special emphasis on the diagnostic and radiation dose requirements. The examinations were selected at random from brain examinations performed over a period of a month at eight scanners of the CT Pace range. Achievement of image criteria was evaluated by two independent observers. The most important preliminary findings concerning image criteria fulfilment or lack of it and disagreements between observers are presented and discussed. The mean values of the proposed dosimetric quantities are compared to the reference values. The examinations performed with and without injection of a contrast agent are also analysed in relation to dosimetric quantities and criteria fulfilment. (author)

  19. Complicated cholecystitis: the complementary roles of sonography and computed tomography.

    Science.gov (United States)

    Charalel, Resmi A; Jeffrey, R Brooke; Shin, Lewis K

    2011-09-01

    Acute cholecystitis is a common cause of abdominal pain in the Western world. Unless treated promptly, patients with acute cholecystitis may develop complications such as gangrenous, perforated, or emphysematous cholecystitis. Because of the increased morbidity and mortality of complicated cholecystitis, early diagnosis and treatment are essential for optimal patient care. Nevertheless, complicated cholecystitis may pose significant challenges with cross-sectional imaging, including sonography and computed tomography (CT). Interpreting radiologists should be familiar with the spectrum of sonographic findings seen with complicated cholecystitis and as well as understand the complementary role of CT. Worrisome imaging findings for complicated cholecystitis include intraluminal findings (sloughed mucosa, hemorrhage, abnormal gas), gallbladder wall abnormalities (striations, asymmetric wall thickening, abnormal gas, loss of sonoreflectivity and contrast enhancement), and pericholecystic changes (echogenic fat, pericholecystic fluid, abscess formation). Finally, diagnosis of complicated cholecystitis by sonography and CT can guide alternative treatments including minimally invasive percutaneous and endoscopic options.

  20. Application of cone beam computed tomography in facial imaging science

    Institute of Scientific and Technical Information of China (English)

    Zacharias Fourie; Janalt Damstra; Yijin Ren

    2012-01-01

    The use of three-dimensional (3D) methods for facial imaging has increased significantly over the past years.Traditional 2D imaging has gradually being replaced by 3D images in different disciplines,particularly in the fields of orthodontics,maxillofacial surgery,plastic and reconstructive surgery,neurosurgery and forensic sciences.In most cases,3D facial imaging overcomes the limitations of traditional 2D methods and provides the clinician with more accurate information regarding the soft-tissues and the underlying skeleton.The aim of this study was to review the types of imaging methods used for facial imaging.It is important to realize the difference between the types of 3D imaging methods as application and indications thereof may differ.Since 3D cone beam computed tomography (CBCT) imaging will play an increasingly importanl role in orthodontics and orthognathic surgery,special emphasis should be placed on discussing CBCT applications in facial evaluations.

  1. Transcolonic retrograde ureteric catheterization assisted by 3-d computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Snow, T.M.; Olivier, J.; Vigar, M. [Gold Coast Hospital, Southport, QLD (Australia). Department of Radiology; Parnham, A.P. [Gold Coast Hospital, Southport, QLD (Australia). Department of Radiology

    1999-08-01

    A 42-year-old woman had bladder extrophy at birth, treated by ureterocolic anastomosis of her single kidney. She suffered recurrent hyperammonaemia, leading to comas, but refused an ileal conduit. During her most recent coma, it was decided to divert her urine to test whether this would reduce hyperammonaemia: this was accomplished by transcolonic retrograde catheterization of the ureter. This was only possible after computed tomography ureterography to show the ureterocolic anastomosis. Ureterocolic anastomosis is associated with several complications, the best known being hyperchloraemic acidosis and potassium deficiency. There is also a very high incidence of stricture at the anastomosis, both benign and malignant. Hyperammonaemia is less common. It can lead to disturbance of consciousness and seizures. It is caused by reabsorption of ammonia from the colon, exacerbated by the presence of urea-splitting organisms. Copyright (1999) Blackwell Science Pty Ltd 8 refs., 4 figs.

  2. Cholecystocolonic fistula mimicking acute cholecystitis diagnosed unequivocally by computed tomography.

    Science.gov (United States)

    Chick, Jeffrey Forris Beecham; Chauhan, Nikunj Rashmikant; Paulson, Vera Ashley; Adduci, Alexander J

    2013-12-01

    Cholecystocolonic fistula is an uncommon potential complication of cholecystitis found intraoperatively in 0.06-0.14 % of patients undergoing cholecystectomy and 0.1-0.5 % of autopsy series. Although cholecystocolonic fistula is the second most common cholecystoenteric fistula, second only to cholecystoduodenal fistula, it is diagnosed preoperatively in only 7.9 % of patients. Failure to preoperatively diagnose cholecystocolonic fistula places surgeons in precarious positions, as they may be forced to convert a seemingly routine cholecystectomy to a more sophisticated procedure coupled with adhesiolysis, colonic suturing, or colonic resection. We report a young patient who presented to the emergency department with complaints indicative of acute cholecystitis; however, preoperative ultrasound was suggestive of a cholecystoenteric fistula. Computed tomography and pathology were pathognomonic with clear visualization of the cholecystocolonic fistulous tract.

  3. Building a 3D Computed Tomography Scanner From Surplus Parts.

    Science.gov (United States)

    Haidekker, Mark A

    2014-01-01

    Computed tomography (CT) scanners are expensive imaging devices, often out of reach for small research groups. Designing and building a CT scanner from modular components is possible, and this article demonstrates that realization of a CT scanner from components is surprisingly easy. However, the high costs of a modular X-ray source and detector limit the overall cost savings. In this article, the possibility of building a CT scanner with available surplus X-ray parts is discussed, and a practical device is described that incurred costs of less than $16,000. The image quality of this device is comparable with commercial devices. The disadvantage is that design constraints imposed by the available components lead to slow scan speeds and a resolution of 0.5 mm. Despite these limitations, a device such as this is attractive for imaging studies in the biological and biomedical sciences, as well as for advancing CT technology itself.

  4. Cone beam computed tomography: A new vision in dentistry

    Directory of Open Access Journals (Sweden)

    Manas Gupta

    2015-01-01

    Full Text Available Cone beam computed tomography (CBCT is a developing imaging technique designed to provide relatively low-dose high-spatial-resolution visualization of high-contrast structures in the head and neck and other anatomic areas. It is a vital content of a dental patient's record. A literature review demonstrated that CBCT has been utilized for oral diagnosis, oral and maxillofacial surgery, endodontics, implantology, orthodontics; temporomandibular joint dysfunction, periodontics, and restorative and forensic dentistry. Recently, higher emphasis has been placed on the CBCT expertise, the three-dimensional (3D images, and virtual models. This literature review showed that the different indications for CBCT are governed by the needs of the specific dental discipline and the type of procedure performed.

  5. Computed tomography of the retroperitoneum in patients with femoral neuropathy.

    Science.gov (United States)

    Eustace, S; McCarthy, C; O'Byrne, J; Breatnach, E; Fitzgerald, E

    1994-08-01

    The authors illustrate the value of computed tomography (CT) of the retroperitoneum in patients presenting with femoral nerve signs. They describe 28 such patients, examined at a tertiary-care hospital between June 1990 and January 1993, in whom CT of the retroperitoneum contributed significantly to the diagnosis. The patients, 19 males and 9 females, ranged in age from 11 to 81 years. CT showed disease of the psoas compartment in 17 cases; the condition was due to a malignant lesion in 9 cases and was secondary to infection in 5 and to other causes in 3. Disease of the iliacus compartment was shown in 11 cases; it was due to a malignant lesion in 6 cases and was secondary to hemorrhage in 2, to infection in 1 and to a bursa in 1. The diagnostic features of the diseases encountered are discussed, and the importance of performing CT early is stressed.

  6. Cone Beam Computed Tomography Evaluation of Inverted Mesiodentes.

    Science.gov (United States)

    Al-Sehaibany, Fares S; Marzouk, Hazem M; Salama, Fouad S

    2016-01-01

    A mesiodens is the most common type of supernumerary teeth. The purpose of this report is to present a rare occurrence of non-syndromic impacted inverted mesiodentes in an 8.5-year-old boy who presented with a chief complaint of delayed eruption of his permanent maxillary left central incisor. Occlusal and panoramic radiographs, as well as cone beam computed tomography (CBCT) with a three-dimensional (3-D) reconstruction image, confirmed that one supernumerary tooth had perforated the nasal fossa floor and the other was in close approximation to the to the same site. Surgical removal of both mesiodentes was indicated. Radiographic evidence of complete healing was observed 12 months following surgical removal. The use of CBCT with a 3-D reconstruction image as a tool in diagnosis and evaluation of healing after surgical removal is recommended.

  7. PET/Computed Tomography Scanning and Precision Medicine: Esophageal Cancer.

    Science.gov (United States)

    Goel, Reema; Subramaniam, Rathan M; Wachsmann, Jason W

    2017-10-01

    Esophageal cancer commonly has a poor prognosis, which requires an accurate diagnosis and early treatment to improve outcome. Other modalities for staging, such as endoscopic ultrasound imaging and computed tomography (CT) scans, have a role in diagnosis and staging. However, PET with fluorine-18 fluoro-2-deoxy-d-glucose/CT (FDG PET/CT) scanning allows for improved detection of distant metastatic disease and can help to prevent unnecessary interventions that would increase morbidity. FDG PET/CT scanning is valuable in the neoadjuvant chemotherapy assessment and predicting survival outcomes subsequent to surgery. FDG PET/CT scanning detects recurrent disease and metastases in follow-up. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Computed tomography dose optimisation in cystic fibrosis: A review.

    LENUS (Irish Health Repository)

    Ferris, Helena

    2016-04-28

    Cystic fibrosis (CF) is the most common autosomal recessive disease of the Caucasian population worldwide, with respiratory disease remaining the most relevant source of morbidity and mortality. Computed tomography (CT) is frequently used for monitoring disease complications and progression. Over the last fifteen years there has been a six-fold increase in the use of CT, which has lead to a growing concern in relation to cumulative radiation exposure. The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality, but fulfil the requirements of a diagnostic quality CT. Dose-optimisation, particularly in CT, is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 mSv, a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation. This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation.

  9. Recent Developments in Computed Tomography for Urolithiasis: Diagnosis and Characterization

    Directory of Open Access Journals (Sweden)

    P. D. Mc Laughlin

    2012-01-01

    Full Text Available Objective. To critically evaluate the current literature in an effort to establish the current role of radiologic imaging, advances in computed tomography (CT and standard film radiography in the diagnosis, and characterization of urinary tract calculi. Conclusion. CT has a valuable role when utilized prudently during surveillance of patients following endourological therapy. In this paper, we outline the basic principles relating to the effects of exposure to ionizing radiation as a result of CT scanning. We discuss the current developments in low-dose CT technology, which have resulted in significant reductions in CT radiation doses (to approximately one-third of what they were a decade ago while preserving image quality. Finally, we will discuss an important recent development now commercially available on the latest generation of CT scanners, namely, dual energy imaging, which is showing promise in urinary tract imaging as a means of characterizing the composition of urinary tract calculi.

  10. Basal ganglia calcification on computed tomography in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shohei; Tani, Kenji; Ishigatsubo, Yoshiaki and others

    1988-09-01

    The development of basal ganglia calcification was studied in 85 patients with systemic lupus erythematosus (SLE) by computed tomography (CT). Bilateral calcification of the basal ganglia was found to occur in 5 patients (5.9 %) with SLE, but was not seen in patients with rheumatoid arthritis and progressive systemic sclerosis. All were female with a mean age of 42 years (range 29 - 49). The patients with calcification of the basal ganglia had neurological symptoms, such as psychiatric problems (3 cases), grand mal seizures (1 case), CSF abnormalities (2 cases), and EEG changes (4 cases). There were significantly higher incidences of alopecia, cutaneous vasculitis, leukopenia, and thrombocytopenia in the group with calcifications than those in the group with normal CT findings. Circulating immune complexes were detected and LE tests were positive in 2 patients. Endocrinological examination showed no abnormality in any. We suggest that basal ganglia calcification in SLE might be related to cerebral vasculitis.

  11. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2001-09-15

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  12. Effect of object location on the density measurement in cone-beam computed tomography versus multislice computed tomography.

    Science.gov (United States)

    Eskandarloo, Amir; Abdinian, Mehrdad; Salemi, Fatemeh; Hashemzadeh, Zahra; Safaei, Mehran

    2012-12-01

    Bone density measurement in a radiographic view is a valuable method for evaluating the density of bone quality before performing some dental procedures such as, dental implant placements. It seems that Cone-Beam Computed Tomography (CBCT) can be used as a diagnostic tool for evaluating the density of the bone, prior to any treatment, as the reported radiation dose in this method is minimal. The aim of this study is to investigate the effect of object location on the density measurement in CBCT versus Multislice computed tomography (CT). In an experimental study, three samples with similar dimensions, but different compositions, different densities (Polyethylene, Polyamide, Polyvinyl Chloride), and three bone pieces of different parts of the mandibular bone were imaged in three different positions by CBCT and Multislice CT sets. The average density value was computed for each sample in each position. Then the data obtained from each CBCT was converted to a Hounsfield unit and evaluated using a single variable T analysis. A P value <0.05 was considered to be significant. The density in a Multislice CT is stable in the form of a Hounsfield Number, but this density is variable in the images acquired through CBCT, and the change in the position results in significant changes in the density. In this study, a statistically significant difference (P value = 0.000) has been observed for the position of the sample and its density in CBCT in comparison to Multislice CT. Density values in CBCT are not real because they are affected by the position of the object in the machine.

  13. Aggressive primary thyroid lymphoma: imaging features of two elderly patients

    Directory of Open Access Journals (Sweden)

    Eu Hyun Kim

    2014-10-01

    Full Text Available

    We report two cases of aggressive thyroid lymphoma in elderly patients that presented as Epub ahead of print large infiltrative thyroid masses with extensive invasion to adjacent structures including trachea, esophagus, and common carotid artery. Ultrasonography displayed irregular shaped, heterogeneous hypoechoic mass, mimicking anaplastic carcinoma. Computed tomography showed heterogeneously enhancing mass compared to surrounding muscles without calcification and hemorrhage. After biopsy, the masses were histopathologically diagnosed as lymphoma. Aggressive primary thyroid lymphoma is rare; therefore, here we report its image features, with emphasis on ultrasonographic findings, and discuss its differential diagnosis.

  14. Aggressive primary thyroid lymphoma: imaging features of two elderly patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eu Hyun; Kim, Jee Young; Kim, Tae Jung [Yeouido St. Mary' s Hospital, The Catholic University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report two cases of aggressive thyroid lymphoma in elderly patients that presented as Epub ahead of print large infiltrative thyroid masses with extensive invasion to adjacent structures including trachea, esophagus, and common carotid artery. Ultrasonography displayed irregular shaped, heterogeneous hypoechoic mass, mimicking anaplastic carcinoma. Computed tomography showed heterogeneously enhancing mass compared to surrounding muscles without calcification and hemorrhage. After biopsy, the masses were histopathologically diagnosed as lymphoma. Aggressive primary thyroid lymphoma is rare; therefore, here we report its image features, with emphasis on ultrasonographic findings, and discuss its differential diagnosis.

  15. Hodgkin Lymphoma and Castleman Disease: When One Blood Disease Can Hide Another

    Directory of Open Access Journals (Sweden)

    L. Filliatre-Clement

    2017-01-01

    Full Text Available We describe a rare case of Castleman disease associated de novo with Hodgkin lymphoma. The incidence of Castleman disease is rare; only a few studies have described it in de novo association with Hodgkin lymphoma. The patient described here complained of unique evolutionary axillary adenopathy. A positron-emission tomography/computed tomography scan revealed hypermetabolic activity in this area. Diagnosis was based on a total excision biopsy of the adenopathy. The patient underwent complete remission with ABVD (doxorubicin, bleomycin, vinblastine, and dacarbazine chemotherapy for treating Hodgkin lymphoma after surgical excision of the unicentric Castleman disease lesion.

  16. Hodgkin Lymphoma and Castleman Disease: When One Blood Disease Can Hide Another.

    Science.gov (United States)

    Filliatre-Clement, L; Busby-Venner, H; Moulin, C; Roth-Guepin, G; Perrot, A

    2017-01-01

    We describe a rare case of Castleman disease associated de novo with Hodgkin lymphoma. The incidence of Castleman disease is rare; only a few studies have described it in de novo association with Hodgkin lymphoma. The patient described here complained of unique evolutionary axillary adenopathy. A positron-emission tomography/computed tomography scan revealed hypermetabolic activity in this area. Diagnosis was based on a total excision biopsy of the adenopathy. The patient underwent complete remission with ABVD (doxorubicin, bleomycin, vinblastine, and dacarbazine) chemotherapy for treating Hodgkin lymphoma after surgical excision of the unicentric Castleman disease lesion.

  17. (18)F-FDG PET/CT in bilateral primary adrenal T-cell lymphoma.

    Science.gov (United States)

    Santhosh, Sampath; Mittal, Bhagwant Rai; Shankar, Praveen; Kashyap, Raghava; Bhattacharya, Anish; Singh, Baljinder; Das, Ashim; Bhansali, Anil

    2011-01-01

    Primary adrenal lymphoma is extremely rare. We report a young patient who presented with non- specific symptoms of fever and abdominal pain. Conventional imaging modalities demonstrated bilateral bulky adrenal masses, and whole-body fluorine-18-fluorodesoxyglucose ((18)F-FDG) positron emission tomography/computed tomography showed intense (18)F-FDG-avid bilateral adrenal masses with no evidence of extra-adrenal spread. A pathological diagnosis of non-Hodgkin lymphoma of peripheral T-cell type was made. The present case indicates that primary adrenal lymphoma should be included in the differential diagnosis of bilateral adrenal masses.

  18. Quantification and clinical relevance of head motion during computed tomography.

    Science.gov (United States)

    Wagner, Arne; Schicho, Kurt; Kainberger, Franz; Birkfellner, Wolfgang; Grampp, Stephan; Ewers, Rolf

    2003-11-01

    To quantify the 3-dimensional translation and rotation components of head motion during computed tomography and to analyze the influence of such motion on perceptible artifacts and distortion of volume image data sets. Using high-precision optoelectronic motion-capture technology, changes in patient head position during axial CT scanning were registered in 20 cases and 2 phantoms with a spatial relative resolution better than 0.003 cm. Statistical analysis was performed on a base of 6-dimensional measurement-vectors, each with 3 translation and 3 rotation values. Because of the recording frequency of the tracking system, more than 80000 values were included in a statistical analysis. All 20 patients had head motion during the CT scanning, with only 4 of 20 patients showing perceptible motion artifacts. The frequency, the extent, and the direction of the movements did not correlate with either the observations made by the radiologic staff or with the patient's subjective estimation of comfort. Translation movements of the head during CT accounted for a maximum of 0.5 cm and rotations of more than 2 degrees without perceptible motion artifacts. The extent of positional changes of the head was found to correlate with the duration of scanning (Pearson's correlation coefficient: 0.647 for translation shifts, 0.453 for rotation shifts). The mean direction of head motion could be characterized predominantly as a rotation around the longitudinal axis of the body (xy plane) at a significance level of 0.01. Computed tomography evaluations of the head performed without rigid fixation suffer a spatial distortion of the volume image data sets, caused by interimage motion. The absence of motion artifacts is not correlated with the absence of motion.

  19. Multiscale and multimodality computed tomography for cortical bone analysis

    Science.gov (United States)

    Ostertag, A.; Peyrin, F.; Gouttenoire, P. J.; Laredo, J. D.; DeVernejoul, M. C.; Cohen Solal, M.; Chappard, C.

    2016-12-01

    In clinical studies, high resolution peripheral quantitative computed tomography (HR-pQCT) is used to separately evaluate cortical bone and trabecular bone with an isotropic voxel of 82 µm3, and typical cortical parameters are cortical density (D.comp), thickness (Ct.Th), and porosity (Ct.Po). In vitro, micro-computed tomography (micro-CT) is used to explore the internal cortical bone micro-structure with isotropic voxels and high resolution synchrotron radiation (SR); micro-CT is considered the ‘gold standard’. In 16 tibias and 8 femurs, HR-pQCT measurements were compared to conventional micro-CT measurements. To test modality effects, conventional micro-CT measurements were compared to SR micro-CT measurements at 7.5 µm3 SR micro-CT measurements were also tested at different voxel sizes for the femurs, specifically, 7.5 µm3 versus 2.8 µm3. D.comp (r  =  -0.88, p  images provided consistent results compared to those obtained using conventional micro-CT at the distal tibia. D.comp was highly correlated to Po.V/TV because it considers both the micro-porosity (Haversian systems) and macro-porosity (resorption lacunae) of cortical bone. The complexity of canal organization, (including shape, connectivity, and surface) are not fully considered in conventional micro-CT in relation to beam hardening and cone beam reconstruction artifacts. With the exception of Po.V/TV measurements, morphological and topological measurements depend on the characteristics of the x-ray beam, and to a lesser extent, on image resolution.

  20. Sex estimation from sternal measurements using multidetector computed tomography.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation.

  1. Evaluation of computer tomography in cerebro-vascular disease (Strokes)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Sik; Baek, Seung Yon; Rhee, Chung Sik; Kim, Hee Seup [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    1984-06-15

    Most of cerebrovascular disease are composed of vascular occulusive changes and hemorrhage. Now a day, the computed tomography is the best way for evaluation of cerebrovascular disease including detection of nature, location, and associated changes. This study includes evaluation of computed tomography of 70 patients with cerebrovascular disease during the period of 10 months from April. 1983 to Feb. 1984 in Department of Radiology, Ewha Womans University Hospital. The results were as follows: 1. Age distribution of the total 70 patients was broad ranging from 25 years to 79 years. 78.6% of patients were over the age of 50. The male and female sex ratio was 1.4:1. 2. 4 out of 70 patients were normal and 66 patients revealed abnormal on C.T. findings; those were intracranial hemorrhage (28 patients), cerebral infarction (34 patients) and brain atrophy (4 patients). 3. In cases of cerebral infarction, the cerebral hemisphere was most common site of lesion (28 cases), and next was basal ganglia (2 cases). Most of the infarcts in cerebral hemisphere were located in the parietal and temporal lobes. 4. In cases of intracranial hemorrhage, the basal ganglia was most common site of lesion (15 cases). The next common site was cerebral hemisphere (9 cases). 6 patients of all intracranial hemorrhage were combined with intraventricular hemorrhage. Ratio of right and left was 2:3. 5. In patients with motor weakness or hemiparesis, more common findings on CT scan were cerebral infarction. In case with hemiplegia, more common CT findings were intracerebral hemorrhage. 6. Of the 40 cases thought to be cerebral infarction initially by clinical findings and spinal tap. 8 cases (20.0%) were proved to be cerebral hemorrhage by the CT scan. However, of the 22 cases thought to be cerebral hemorrhage, initially, only two cases (9.0%) were cerebral infarction.

  2. Actinomycosis involving the liver. Computed tomography/ultrasound correlation.

    Science.gov (United States)

    Sheth, S; Fishman, E K; Sanders, R

    1987-06-01

    The clinical profile of pelvic actinomycosis, which is being recognized with increased frequency in IUD users, can be misleading in such patients and lead to dangerous delays in diagnosis. The authors present a case in which an IUD user initially sought medical attention for multiple liver abscesses secondary to spread from unsuspected ovarian actinomycosis. The 43-year-old patient, who was admitted with right upper quadrant pain and fever, had a 15-year history of IUD use, although the device had been removed 1 year prior to admission for apparent infection in the left ovary. Ultrasound revealed mixed cystic and solid liver lesions as well as a complex subcapsular fluid collection. A solid left adnexal mass was demonstrated in the pelvis. Computed tomography scan indicated extension of 1 of the complex cystic liver lesions through the liver capsule and into the abdominal wall. Needle aspirations of the liver lesions yielded thick pus that was later identified as Actinomyces israelii. Actinomycosis was evident in the ovarian lesion. Colonization of the vagina and uterus by actinomycosis has been reported by 1.6-5.3% of IUD users, and the risk appears to increase when the same IUD is used for a prolonged time period. In this case, neither the computed tomography scan nor ultrasound suggested an inflammatory process of the left ovary. Aspiration of a liver lesion under ultrasound guidance was necessary for the correct diagnosis. Since actinomycosis has the potential to spread to extrapelvic organs such as the peritoneum, liver, and brain, early diagnosis is essential.

  3. Artifacts in computed tomography scanning of moving objects.

    Science.gov (United States)

    Chen, George T Y; Kung, Jong H; Beaudette, Kevin P

    2004-01-01

    Target volumes in the thorax and abdomen are commonly computed tomography (CT) scanned during light respiration. In this article, we analyze the distortions introduced in helical scanning of moving objects. Objects of known geometry are placed on a moving sled and scanned in a multirow helical CT scanner. The motion of the sled approximates the magnitude and velocity of organ movement in patients during light respiration (amplitude 1 cm, period 4 seconds). Scans of the phantom are obtained in high speed mode at incremental phases of respiration, and the resulting images are compared with scans obtained when the phantom is static. Computer simulations of the scan process are also performed to interpret the results and extend the analysis to a greater range of parameters in scanning, motion, and object size. Resulting scans show that spherical test objects can be shortened by as much as 2 cm or twice the periodic motion amplitude. Object shape was significantly distorted, and the geometric center of the object was displaced by as much as +/-0.8 cm. Computer simulation results qualitatively agree with the experimentally observed phantom images. These simulations predict that the effect is clearly observable even if the amplitude is decreased to 0.5 cm. Implications of scanning moving objects on treatment planning are discussed.

  4. 99mTc-methylene diphosphonate single-photon emission computed tomography/computed tomography improves the diagnostic accuracy of osteoid osteoma

    Science.gov (United States)

    Squier, Samuel Brian; Lewis, Jacob Ian; Accurso, Joseph Matthew; Jain, Manoj Kumar

    2016-01-01

    We present a case of a 17-year-old football player who had previously received multiple facet joint injections for presumed secondary osteoarthritis. 99mTc-methylene diphosphonate single-photon emission computed tomography/computed tomography imaging of the cervical spine demonstrated focal increased radiopharmaceutical activity in the right C2 lamina, which was associated with an osteolytic lesion with a central irregular sclerotic nidus. Surgical pathology confirmed an osteoid osteoma. PMID:27833319

  5. Time-Domain Terahertz Computed Axial Tomography NDE System

    Science.gov (United States)

    Zimdars, David

    2012-01-01

    NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D

  6. Enhancement of photoacoustic tomography in the tissue with speed-of-sound variance using ultrasound computed tomography

    Institute of Scientific and Technical Information of China (English)

    程任翔; 陶超; 刘晓峻

    2015-01-01

    The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo-geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography to enhance the photoacoustic tomography in this situation. The speed-of-sound information is recovered by ultrasound computed to-mography. Then, an improved delay-and-sum method is used to reconstruct the image from the photoacoustic signals. The simulation results validate that the proposed method can obtain a better photoacoustic tomography than the conventional method when the speed-of-sound variance is increased. In addition, the influences of the speed-of-sound variance and the fan-angle on the image quality are quantitatively explored to optimize the image scheme. The proposed method has a good performance even when the speed-of-sound variance reaches 14.2%. Furthermore, an optimized fan angle is revealed, which can keep the good image quality with a low cost of hardware. This study has a potential value in extending the biomedical application of photoacoustic tomography.

  7. Centre of Rotation Determination Using Projection Data in X-ray Micro Computed Tomography

    OpenAIRE

    Olander, Birger

    1994-01-01

    There are several methods available to determine the Centre Of Rotation, COR, and align detectors and X-ray focus to COR in X-ray computed tomography. Some methods use narrow rods/needles or specially made alignment objects or phantoms. In X-ray Micro Computed Tomography (or Computerized Micro Tomography), μCT (CMT), methods using sample projection data for COR measurements are preferred since the replacement of alignment objects with samples often displace translation stages and make the ali...

  8. The diagnostic yield of fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in recurrent testicular seminoma

    Directory of Open Access Journals (Sweden)

    Athanasios Bantis

    2016-01-01

    Full Text Available The use of positron emission tomography-computed tomography (PET-CT scan imaging is undoubtedly a significant evolution in oncological urology, although at present of limited use in every day urology practice. The aim of this study is to highlight the indication and diagnostic accuracy of fluorine-18 fluorodeoxyglucose PET/CT in the staging of a patient with metachronous bilateral testicular seminoma, elevated tumor markers, and equivocal conventional imaging findings.

  9. Role of computed tomography and radionuclide scintigraphy in the localization of osteomyelitis in flat bones

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Conway, J.J.; Poznanski, A.K.; Tachdjian, M.O.; Dias, L.S.; Kelikian, A.S.

    1985-03-01

    The combined use of radionuclide scintigraphy and computed tomography is recommended for evaluating children with laboratory and clinical data suggestive of flat bone osteomyelitis despite normal conventional radiographs. In addition, computed tomography may be helpful in the presence of abnormal radiographs in determining the exact location of the focus of osteomyelitis and the most suitable route for appropriate drainage or to obtain culture material.

  10. Just Scan It!-Weapon Reconstruction in Computed Tomography on Historical and Current Swiss Military Guns.

    Science.gov (United States)

    Franckenberg, Sabine; Binder, Thomas; Bolliger, Stephan; Thali, Michael J; Ross, Steffen G

    2016-09-01

    Cross-sectional imaging, such as computed tomography, has been increasingly implemented in both historic and recent postmortem forensic investigations. It aids in determining cause and manner of death as well as in correlating injuries to possible weapons. This study illuminates the feasibility of reconstructing guns in computed tomography and gives a distinct overview of historic and recent Swiss Army guns.

  11. Quantitative computed tomography measures of emphysema and airway wall thickness are related to respiratory symptoms

    DEFF Research Database (Denmark)

    Grydeland, Thomas B; Dirksen, Asger; Coxson, Harvey O

    2010-01-01

    There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness.......There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness....

  12. Visualization of simulated small vessels on computed tomography using a model-based iterative reconstruction technique

    Directory of Open Access Journals (Sweden)

    Toru Higaki

    2017-08-01

    Full Text Available This article describes a quantitative evaluation of visualizing small vessels using several image reconstruction methods in computed tomography. Simulated vessels with diameters of 1–6 mm made by 3D printer was scanned using 320-row detector computed tomography (CT. Hybrid iterative reconstruction (hybrid IR and model-based iterative reconstruction (MBIR were performed for the image reconstruction.

  13. Quantitative computed tomography measures of emphysema and airway wall thickness are related to respiratory symptoms

    DEFF Research Database (Denmark)

    Grydeland, Thomas B; Dirksen, Asger; Coxson, Harvey O

    2010-01-01

    There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness.......There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness....

  14. Multi-dimensional visualization of coronary aberrancies using multi detector computed tomography

    NARCIS (Netherlands)

    van Ooijen, P; Dorgelo, J; Tukker, W; Willemsen, H; Oudkerk, M; Lewis, BS; Halon, DA; Flugelman, MY; Gensini, GF

    2003-01-01

    The purpose of this study was to evaluate the usefulness of three and four dimensional visualization of multi detector computed tomography datasets for the evaluation of coronary aberrancies. Multi detector computed tomography (MDCT) datasets were obtained in thirteen patients following a standard p

  15. Dynamic 3D computed tomography scanner for vascular imaging

    Science.gov (United States)

    Lee, Mark K.; Holdsworth, David W.; Fenster, Aaron

    2000-04-01

    A 3D dynamic computed-tomography (CT) scanner was developed for imaging objects undergoing periodic motion. The scanner system has high spatial and sufficient temporal resolution to produce quantitative tomographic/volume images of objects such as excised arterial samples perfused under physiological pressure conditions and enables the measurements of the local dynamic elastic modulus (Edyn) of the arteries in the axial and longitudinal directions. The system was comprised of a high resolution modified x-ray image intensifier (XRII) based computed tomographic system and a computer-controlled cardiac flow simulator. A standard NTSC CCD camera with a macro lens was coupled to the electro-optically zoomed XRII to acquire dynamic volumetric images. Through prospective cardiac gating and computer synchronized control, a time-resolved sequence of 20 mm thick high resolution volume images of porcine aortic specimens during one simulated cardiac cycle were obtained. Performance evaluation of the scanners illustrated that tomographic images can be obtained with resolution as high as 3.2 mm-1 with only a 9% decrease in the resolution for objects moving at velocities of 1 cm/s in 2D mode and static spatial resolution of 3.55 mm-1 with only a 14% decrease in the resolution in 3D mode for objects moving at a velocity of 10 cm/s. Application of the system for imaging of intact excised arterial specimens under simulated physiological flow/pressure conditions enabled measurements of the Edyn of the arteries with a precision of +/- kPa for the 3D scanner. Evaluation of the Edyn in the axial and longitudinal direction produced values of 428 +/- 35 kPa and 728 +/- 71 kPa, demonstrating the isotropic and homogeneous viscoelastic nature of the vascular specimens. These values obtained from the Dynamic CT systems were not statistically different (p less than 0.05) from the values obtained by standard uniaxial tensile testing and volumetric measurements.

  16. Value of computer tomography and sonography in the investigation of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, K.; Frommhold, H.; Grauthoff, H.; Moedder, U.; Heuser, L. Braun, G.; Buurman, R.; Scherer, K. (Bonn Univ. (Germany, F.R.). Radiologische Klinik; Hamburg Univ. (Germany, F.R.). Radiologische Klinik und Strahleninstitut; Koeln Univ. (Germany, F.R.). Radiologisches Inst. und Poliklinik)

    1980-05-01

    Three hundred and five patients were examined by computer tomography and sonography. In 117 patients no abnormalities were found in the pancreas. The accuracy of computer tomography was 87%, of sonography 85%. In 41 patients the presence of a carcinoma of the pancreas was confirmed histologically. In this group the sensitivity of computer tomography was 83%, of sonography 85%. Thirty-four patients suffered from acute pancreatitis. In this group sensitivity of the two methods was equal at 79%. 113 patients had changes of chronic pancreatitis. Sensitivity of computer tomography was 84%, of sonography 70%. Computer tomography is better at demonstrating calcification in the pancreas. Atrophy of the pancreas cannot be diagnosed by sonography.

  17. Comparison of Adsorbed Skin Dose Received by Patients in Cone Beam Computed Tomography, Spiral and Conventional Computed Tomography Scanninng

    Directory of Open Access Journals (Sweden)

    Rahimi A

    2011-12-01

    Full Text Available Background and Aims: The evaluation of absorbed dose received by patients could give useful information for radiation risk estimation. This study was performed to compare the entrance skin dose received by patients in cone beam computed tomography (CBCT, conventional and spiral computed tomography (CT.Materials and Methods: In this experimental study, 81 calibrated TLD chips were used. the TLD chips were placed on facial, thyroid and end of sternum skin surface in patients referred for CT of the paranasal sinuses(3 TLD chips for each area to estimate the absorbed dose received by central part of radiation field, thyroid and out of field areas, respectively. The data were analyzed using one-way ANOVA and Tukey tests. Results: The dose delivered to the center of irradiated field was about 0.79±0.09 mGy in CBCT technique compared with 16.31±3.71 and 18.84±4.12 mGy for spiral and conventional CT, respectively. The received dose by the out of field areas was about 54 percent of central area dose. There was statistical significant relationship between the imaging modalities and absorbed dose received by patients (P=0.016. The least absorbed dose was for CBCT and the greatest dose was for conventional CT imaging technique.Conclusion: The dose delivered to central area of irradiated field in conventional and spiral CT imaging modalities was about 24 times greater than of that in CBCT. Also, the highest received dose was for central area of radiated field and the lowest dose was for the out of field areas.

  18. The predictive role of interim positron emission tomography for Hodgkin lymphoma treatment outcome is confirmed using the interpretation criteria of the Deauville five-point scale.

    Science.gov (United States)

    Gallamini, Andrea; Barrington, Sally F; Biggi, Alberto; Chauvie, Stephane; Kostakoglu, Lale; Gregianin, Michele; Meignan, Michel; Mikhaeel, George N; Loft, Annika; Zaucha, Jan M; Seymour, John F; Hofman, Michael S; Rigacci, Luigi; Pulsoni, Alessandro; Coleman, Morton; Dann, Eldad J; Trentin, Livio; Casasnovas, Olivier; Rusconi, Chiara; Brice, Pauline; Bolis, Silvia; Viviani, Simonetta; Salvi, Flavia; Luminari, Stefano; Hutchings, Martin

    2014-06-01

    A retrospective, international, multicenter study was undertaken to assess: (i) the prognostic role of 'interim' positron emission tomography performed during treatment with doxorubicin, bleomycin, vinblastine and dacarbazine in patients with Hodgkin lymphoma; and (ii) the reproducibility of the Deauville five-point scale for the interpretation of interim positron emission tomography scan. Two hundred and sixty patients with newly diagnosed Hodgkin lymphoma were enrolled. Fifty-three patients with early unfavorable and 207 with advanced-stage disease were treated with doxorubicin, bleomycin, vinblastine and dacarbazine ± involved-field or consolidation radiotherapy. Positron emission tomography scan was performed at baseline and after two cycles of chemotherapy. Treatment was not changed according to the results of the interim scan. An international panel of six expert reviewers independently reported the scans using the Deauville five-point scale, blinded to treatment outcome. Forty-five scans were scored as positive (17.3%) and 215 (82.7%) as negative. After a median follow up of 37.0 (2-110) months, 252 patients are alive and eight have died. The 3-year progression-free survival rate was 83% for the whole study population, 28% for patients with interim positive scans and 95% for patients with interim negative scans (Pinterim positron emission tomography scans for predicting treatment outcome were 0.73, 0.94, 0.94 and 0.73, respectively. Binary concordance amongst reviewers was good (Cohen's kappa 0.69-0.84). In conclusion, the prognostic role and validity of the Deauville five-point scale for interpretation of interim positron emission tomography scans have been confirmed by the present study.

  19. Iterative image reconstruction and its role in cardiothoracic computed tomography.

    Science.gov (United States)

    Singh, Sarabjeet; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Padole, Atul; Lira, Diego; Kalra, Mannudeep K

    2013-11-01

    Revolutionary developments in multidetector-row computed tomography (CT) scanner technology offer several advantages for imaging of cardiothoracic disorders. As a result, expanding applications of CT now account for >85 million CT examinations annually in the United States alone. Given the large number of CT examinations performed, concerns over increase in population-based risk for radiation-induced carcinogenesis have made CT radiation dose a top safety concern in health care. In response to this concern, several technologies have been developed to reduce the dose with more efficient use of scan parameters and the use of "newer" image reconstruction techniques. Although iterative image reconstruction algorithms were first introduced in the 1970s, filtered back projection was chosen as the conventional image reconstruction technique because of its simplicity and faster reconstruction times. With subsequent advances in computational speed and power, iterative reconstruction techniques have reemerged and have shown the potential of radiation dose optimization without adversely influencing diagnostic image quality. In this article, we review the basic principles of different iterative reconstruction algorithms and their implementation for various clinical applications in cardiothoracic CT examinations for reducing radiation dose.

  20. Compensation for air voids in photoacoustic computed tomography image reconstruction

    Science.gov (United States)

    Matthews, Thomas P.; Li, Lei; Wang, Lihong V.; Anastasio, Mark A.

    2016-03-01

    Most image reconstruction methods in photoacoustic computed tomography (PACT) assume that the acoustic properties of the object and the surrounding medium are homogeneous. This can lead to strong artifacts in the reconstructed images when there are significant variations in sound speed or density. Air voids represent a particular challenge due to the severity of the differences between the acoustic properties of air and water. In whole-body small animal imaging, the presence of air voids in the lungs, stomach, and gastrointestinal system can limit image quality over large regions of the object. Iterative reconstruction methods based on the photoacoustic wave equation can account for these acoustic variations, leading to improved resolution, improved contrast, and a reduction in the number of imaging artifacts. However, the strong acoustic heterogeneities can lead to instability or errors in the numerical wave solver. Here, the impact of air voids on PACT image reconstruction is investigated, and procedures for their compensation are proposed. The contributions of sound speed and density variations to the numerical stability of the wave solver are considered, and a novel approach for mitigating the impact of air voids while reducing the computational burden of image reconstruction is identified. These results are verified by application to an experimental phantom.