WorldWideScience

Sample records for lymphography

  1. Quantitative lymphography

    International Nuclear Information System (INIS)

    Mostbeck, A.; Lofferer, O.; Kahn, P.; Partsch, H.; Koehn, H.; Bialonczyk, Ch.; Koenig, B.

    1984-01-01

    Labelled colloids and macromolecules are removed lymphatically. The uptake of tracer in the regional lymphnodes is a parameter of lymphatic flow. Due to great variations in patient shape - obesity, cachexia - and accompanying variations in counting efficiencies quantitative measurements with reasonable accuracy have not been reported to date. A new approach to regional absorption correction is based on the combination of transmission and emission scans for each patient. The transmission scan is used for calculation of an absorption correction matrix. Accurate superposition of the correction matrix and the emission scan is achieved by computing the centers of gravity of point sources and - in the case of aligning opposite views - by cross correlation of binary images. In phantom studies the recovery was high (98.3%) and the coefficient of variation of repeated measurement below 1%. In patient studies a standardized stress is a prerequisite for reliable and comparable results. Discrimination between normals (14.3 +- 4.2D%) and patients with lymphedema (2.05 +- 2.5D%) was highly significant using praefascial lymphography and sc injection. Clearence curve analysis of the activities at the injection site, however, gave no reliable data for this purpose. In normals, the uptake in lymphnodes after im injection is by one order of magnitude lower then the uptake after sc injection. The discrimination between normals and patients with postthromboic syndrome was significant. Lymphography after ic injection was in the normal range in 2/3 of the patients with lymphedema and is therefore of no diagnostic value. The difference in uptake after ic and sc injection demonstrated for the first time by our quantitative method provides new insights into the pathophysiology of lymphedema and needs further investigation. (Author)

  2. Lymphography - an outdated technique

    International Nuclear Information System (INIS)

    Peters, P.E.

    1982-01-01

    The indications for lymphography have changed with the availability of non-invasive techniques like ultrasonic techniques and computerized tomography. This review discusses: Recent results of lymphography in histologically verified patient collectives with lymphatic systemic diseases and lymphatic metastizing tumors. The present role of lymphography is derived from this status report as well as the future perspectives. (orig.) [de

  3. Noncontrast Magnetic Resonance Lymphography.

    Science.gov (United States)

    Arrivé, Lionel; Derhy, Sarah; El Mouhadi, Sanaâ; Monnier-Cholley, Laurence; Menu, Yves; Becker, Corinne

    2016-01-01

    Different imaging techniques have been used for the investigation of the lymphatic channels and lymph glands. Noncontrast magnetic resonance (MR) lymphography has significant advantages in comparison with other imaging modalities. Noncontrast MR lymphography uses very heavily T2-weighted fast spin echo sequences which obtain a nearly complete signal loss in tissue background and specific display of lymphatic vessels with a long T2 relaxation time. The raw data can be processed with different algorithms such as maximum intensity projection algorithm to obtain an anatomic representation. Standard T2-weighted MR images easily demonstrate the location of edema. It appears as subcutaneous infiltration of soft tissue with a classical honeycomb pattern. True collection around the muscular area may be demonstrated in case of severe lymphedema. Lymph nodes may be normal in size, number, and signal intensity; in other cases, lymph nodes may be smaller in size or number of lymph nodes may be restricted. MR lymphography allows a classification of lymphedema in aplasia (no collecting vessels demonstrated); hypoplasia (a small number of lymphatic vessels), and numerical hyperplasia or hyperplasia (with an increased number of lymphatic vessels of greater and abnormal diameter). Noncontrast MR lymphography is a unique noninvasive imaging modality for the diagnosis of lymphedema. It can be used for positive diagnosis, differential diagnosis, and specific evaluation of lymphedema severity. It may also be used for follow-up evaluation after treatment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Thoracic duct lymphography by subcutaneous contrast agent ...

    African Journals Online (AJOL)

    A second lymphography revealed a collateral thoracic duct that was not detected during the first lymphography. The collateral duct was ligated and chylothorax was resolved after the second surgery. The lymphography applied in this study was minimally-invasive and easily provided images of the thoracic duct in a dog with ...

  5. Experimental and clinical studies on CT lymphography

    International Nuclear Information System (INIS)

    Hirata, Yuzo; Kono, Michio

    1982-01-01

    Indirect lymphography using computed tomographic apparatus (CT Lymphography) was attempted in 15 dogs with newly devised contrast medium for the opacification of hilar and mediastinal lymphnodes. Clinical application was performed in 2 cases of lung cancer. Newly devised contrast material is an emulsion, which consists of oily contrast medium, non-ionic surfactant and glucose solution. The contrast medium was injected percutaneously into subdiaphragmatic space, or into bronchial walls by bronchofiberscopic technique. CT was able to demonstrate the opacified hilar and mediastinal nodes much more in number than demonstrated in conventional radiograms. It was true in 6 to 11 cases when injected into subdiaphragmatic spaces, and in 2 of 4 cases with an injection into bronchial walls. In clinical studies, CT revealed opacification of mediastinal nodes in one case of lung cancer. Although the procedure is still inferior to the demonstrability of routine indirect lymphography for the evaluation of the fine structure of each node, it showed no remarkable side effects. As the satisfactory method of opacifying hilar and mediastinal nodes has not yet been established, our method is thought to be of value in applying for detection of the metastatic lymphnodes. (author)

  6. Lymphography prior to laparoscopic Palomo varicocelectomy to prevent postoperative hydrocele.

    Science.gov (United States)

    Chiarenza, Salvatore F; D'Agostino, Sergio; Scarpa, Mariagrazia; Fabbro, Mariangelica; Costa, Lorenzo; Musi, Luciano

    2006-08-01

    We report our experience with preoperative lymphography to identify and perioperatively preserve the ligature of the lymphatic vessels to reduce the incidence of postoperative testicular hydrocele in patients undergoing laparoscopic Palomo varicocelectomy for adolescent varicocele. Twenty-seven consecutive patients with varicocele had preoperative lymphography. The mean age was 13.5 years (range, 8-18 years) and the mean grade of varicocele was III. We performed lymphography with intrascrotal isosulfan blue. The laparoscopic Palomo procedure was successfully carried out in all patients. In 17 patients (63%) we were able to identify and conserve the lymphatic vessels by lymphography. Mean follow-up was 9.5 months (range, 6-24 months). None of the 27 patients had a recurrence. None of the 17 patients with positive lymphography had a testicular hydrocele. One of the 10 remaining patients developed a sizable hydrocele. Preoperative lymphography prior to laparoscopic Palomo varicocelectomy is a simple and feasible method for preventing testicular hydrocele. However, the method should be standardized to identify the exact site, the correct level of injection of blue dye, and to determine the optimal time to perform lymphography prior to the procedure.

  7. Microlithiasis pulmonum after iodine-lipiodol lymphography

    International Nuclear Information System (INIS)

    Tiedjen, K.U.; Kosberg, R.; Krueger, G.

    1986-01-01

    A pulmonary fibrosis with marked calcifications in a 83 year old female patient is reported. With previous unconspicuous thoracic x-ray findings (1975 and 1978) a bipedal oily lymphography was carried out for diagnosis of a systemic malignant lymphoma. The calcifiing pulmonary fibrosis was investigated with the help of tomographhy, xeroradiography, scintigraphy of the lung and the sceletal system as well as magnetic resonance imaging. A biopsy was denied by the patient. The etiological possibilities of an idiopathic disease as well as an induction by the oily contrast medium and a concomitant affection of a malignant lymphoma are discussed. (orig./WL) [de

  8. Use of labelled dextran in radionuclide lymphography

    International Nuclear Information System (INIS)

    Kafka, P.; Kubicek, J.; Duska, F.; Vizda, J.

    1986-01-01

    Dextran labelled with 99m Tc is a new promising radiopharmaceutical for radionuclide lymphography. So far colloids were mainly used which either had an unsuitable type of emitted radiation or the particles were too large. Dextran with a molecular weight of 70,000 was used. This weight is optimal with regard to the quality of imaging and the risk of adverse reactions. The procedure of labelling is described in detail. The properties of labelled dextran were studied in experiments on dogs weighing 8 to 12 kg to whom 14.8 to 22.2 MBq was administered subcutaneously into the front or hind paws. Scans were made immediately on application and after 45 mins. A quick passage was detected of the labelled dextran from interstitial spaces to the lymphatic vessels. Lymph nodes were well visualized within 1 hour. The quality control of the prepared 99m Tc-dextran was made using paper chromatography; 10 to 20% of free technetium was found. The replacement of colloids used so far with the new preparation seems to be feasible. Examinations using colloids with 198 Au require the patient to be present for 2 days, while dextran tests will be a matter of 1 to 2 hours. (A.K.)

  9. Studies on the diagnostic accuracy of lymphography

    International Nuclear Information System (INIS)

    Luening, M.; Stargardt, A.; Abet, L.

    1979-01-01

    Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is recommended, among other things, for performance control at the end of training and continuing education courses in other fields of x-ray diagnosis as well. (orig.) [de

  10. Modern radiographic contrast agents for lymphography and prospects for their function

    International Nuclear Information System (INIS)

    Sviridov, N.K.

    1985-01-01

    Modern radiopaque agents (RPA) for lymphography are considered as well as prospects for the use of the latest RPA, synthesized by a number of firms, in direct and indirect lymphography. Due to the fact that all oil RPA cause a number of complications, investigations to find new nonionogenic RPA for lymphography are carried out. Reproduction of the best RPA in our country is an actual and urgent task

  11. Computed tomography lymphography for the detection of sentinel nodes in patients with gastric carcinoma

    International Nuclear Information System (INIS)

    Tsujimoto, Hironori; Yaguchi, Yoshihisa; Sakamoto, Naoko

    2010-01-01

    The sentinel node (SN) concept has been found to be feasible in gastric cancer. However, the lymphatic network of gastric cancer may be more complex, and it may be difficult to visualize all the SN distributed in unexpected areas by conventional modalities. In this study, we evaluate the feasibility and efficacy of CT lymphography for the detection of SN in gastric cancer. A total 24 patients with early gastric cancer were enrolled in the study. Three modalities (CT lymphography, dye and radioisotope [RI] methods) were used for the detection of SN. The images of CT lymphography were obtained at 10 min after injection of contrast agents. The SN were successfully identified by CT lymphography in 83.3% of patients; detection rates by the dye and RI methods were 95% and 100%, respectively. Most patients, in whom SN were successfully detected by CT lymphography, had positive results at 5 min after injection of the contrast material. The SN stations detected by CT lymphography were consistent with or included those detected by dye and/or RI methods. In conclusion, CT lymphography for the detection of SN in gastric cancer is feasible and has several advantages. However, based on this initial experience, CT lymphography had a relatively low detection rate compared with conventional methods, and further efforts will be necessary to improve the detection rate and widen the clinical application of CT lymphography for the detection of SN in gastric cancer. (author)

  12. Value of lymphography in the diagnosis of urological tumors

    International Nuclear Information System (INIS)

    Fischer, G.E.

    1981-01-01

    Between 1975 and 1979, 204 lymphadenectomies in patients with tumors of the prostate, kidneys, bladder and testicles were carried through following bilateral pedal lymphography. Referred to all organs, the positive and negative initial lymphographic findings were in accordance with the histological ones in about 67%. The more extended the primary tumor, the greater was the consistency of lymphographic and histological findings. This is most obvious in renal adenocarcinomas. (orig./MG) [de

  13. Thyroid lymphography-computed tomography (TLG-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Koukichi (Kansai Medical Univ., Moriguchi, Osaka (Japan))

    1992-10-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author).

  14. Thyroid lymphography-computed tomography (TLG-CT)

    International Nuclear Information System (INIS)

    Matsuyama, Koukichi

    1992-01-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author)

  15. Video-assisted breast surgery and 3-dimensional computed tomographic mammary lymphography (2). Sentinel node biopsy with 3D-CT mammary lymphography

    International Nuclear Information System (INIS)

    Yamashita, Koji

    2010-01-01

    I have studied endoscopic surgery for breast diseases and 3-dimensional (3D) computed tomographic (CT) lymphography for sentinel node (SN) biopsy. In this second in a series of reports, I explain the techniques of 3D-CT lymphography. 3D-CT lymphography can show the detailed lymphatic flow from the breast tumor toward the SNs and the exact local relation between axillary lymph nodes. I have developed this 3D image-processing system to more precisely depict the anatomical structures of the mammary lymphovascular system. This system allows us to systematically collect axillary lymph nodes, including SNs. 3D-CT lymphography was performed to mark SNs on the skin on the day before surgery. Above the tumor and near the areola, 2 ml of Iopamiron 300 was injected subcutaneously. Sixteen-channel multidetector-row helical CT scan images were obtained 1 minute after injection to detect SNs, and after 3 and 5 minutes to observe lymph flow into the venous angle. The scan images were reconstructed to produce 3D images. SN biopsy was performed with the dye-staining method and endoscopy. 3D-CT lymphography accurately showed lymphatic flow from the tumor to SNs. We classified the relationship between the lymph ducts and the drained SNs into 4 patterns. Following up 3 and 5 minutes after injection of the contrast agent, we can follow the lymph ducts beyond the SN into the second and third nodes toward the venous angle with the complex plexus. The figure of the axillary nodes shows 5 beads-like grouped nodes. 3D-CT lymphography can also recognize the metastatic patterns of the enhanced lymph node. These patterns will predict the metastasis before SN biopsy. 3D-CT lymphography can also be used to detect lymph flow from the arm to avoid harming the arm lymph channel during axillary node dissection and SN biopsy. With 3D-CT lymphography, we can more accurately and precisely recognize lymph flow and the positional relations of SN and axillary nodes to surrounding anatomical structures

  16. Value of Lymphography before and after Radical Hysterectomy in Carcinoma of the Uterine Cervic

    International Nuclear Information System (INIS)

    Kim, Choon Yul; Oh, Yung Ho; Yang, Woo Jin; Bahk, Yong Whee

    1983-01-01

    Radiological demonstration of lymph vessels and lymph nodes may be achieved only by direct lymphography, which is performed by injecting contrast material directly into the lymph vessels, lymph nodes, or occasionally into lymph cysts. Clinical lymphography is performed essentially according to the direct technique of Kinmonth (1952 and 1954). Lymphography has become a routine procedure in patients with carcinoma of the uterine cervix. Thorough assessment of the extent of carcinoma of the uterine cervix is necessary to the intelligent management of any patient with uterine carcinoma. This presentation is to outline the technique of lymphangio-adenography (lymphography), lymphographic finding and diagnostic criteria of the cervical carcinoma, and evaluation of the accuracy of lymphographic diagnosis in cervical carcinoma. A retrospective review of the lymphograms of 145 patients with carcinoma of the uterine cervix was undertaken. All lymphograms were performed at Kang Nam St. Mary's and St. Mary's Hospitals, Catholic Medical College from 1975 to 1982. Of these patients 87 were got radical hysterectomy and lymphographic diagnosis was compared with tissue pathology of the lymph nodes removed, and determined the diagnostic accuracy of lymphography. Lymphography can make a significant contribution in the pretreatment assessment of patients with carcinoma of the uterine cervix. Strick adherence to rigid criteria will yield excellent pathologic correlation in the event of a positive radiographic diagnosis of metastatic carcinoma. Once a positive diagnosis is made, it should influence the management of the cancer patients. The results were as follow: 1. The accuracy of lymphography in diagnosing lymph node matastasis of carcinoma of the uterine cervix was 85.1%, 82.4% in sensitivity and 86.8% in specificity. 2. Metastic lymph nodes were moderately to markedly enlarged and irregular in shape and shown motheaten marginal filling defects in 92.7%. These were ranged from 3mm

  17. Comparison of computed tomography, lymphography, and phlebography in 200 consecutive patients with regard to retroperitoneal metastases from testicular tumor

    International Nuclear Information System (INIS)

    Lien, H.H.; Kolbenstvedt, A.; Talle, K.; Fossa, S.D.; Klepp, O.; Ous, S.

    1983-01-01

    Two hundred patients with testicular tumor were examined by computed tomography (CT), lymphography, and phlebography of the inferior vena cava and left renal and testicular veins. Metastases were demonstrated in 71. CT was positive in 66, lymphography in 60, phlebography in 53, and a combination of lymphography and phlebography in 65. CT was particularly helpful in studying the upper retroperitoneal space and defining the extent of tumor. Lymphography was preferable for demonstrating metastases in non-enlarged, contrastfilled nodes. Phlebography was never the only positive examination and is not recommended as a routine procedure, though it may be helpful in planning surgery. The authors suggest that CT be performed first, followed by lymphography in negative or equivocal cases

  18. Exploration of inner mammary chains by isotopic lymphography

    International Nuclear Information System (INIS)

    Arnaud, D.; Basse-Cathalinat, B.; Blanquet, P.; Dilhuydy, J.M.; Ducassou, D.

    1978-01-01

    The indirect isotopic lymphography of the internal mammary lymph nodes, is an interesting method of investigations as it is the only one which allows the visualization of these nodes, quite difficult to explore. The radioactive molecule used for this study is an antimony sulfocolloid labelled by technetium-99m. This material seems to be the most suitable more for its physical than physiological properties; it is injected into the posterium wall of the rectus muscle on both sides of the medium line. The main parameters obtained from this study on 30 normal and 20 pathological patients give morphological data: number of nodes, their position within intercostal spaces, the width of both chains, their aspect, the presence of subclavicular nodes, or the intercatenar spontaneous passage. On the other hand, the semeiologic data are much more difficult to individualize because of the very great variability of those nodes. Some special shapes give us no doubt as to the spreading of the nodes; but most of the time, just a modification of the scintigram aspect at the time assures us of the extension of neoplasm. This method, almost non invasive for the patient, and for which no local reaction of intolerance has been found, allows the radiotherapist to define its scope of irradiation on each patient, instead of referring himself to literature data, which are only average values [fr

  19. Computed tomography and lymphography of the retroperitoneal space in testicular tumours. A comparison

    Energy Technology Data Exchange (ETDEWEB)

    Cionini, L; Casamassima, F; Villari, N; Pirtoli, L; Forzini, L [Florence Univ. (Italy). Ist. di Radiologia

    1981-01-01

    The value of CT and lymphography of the retroperitoneum was compared in 31 patients with testicular tumors. In no patient with normal or equivocal lymphography was more information gained by CT. In abnormal cases, the presence of metastatic deposits was well detected at both examinations, but CT proved more useful in defining the exact extent of the tumor and facilitated the proper arrangement of the irradiation fields. A strategy in the sequence of investigation in testicular tumors is suggested, aiming to save CT time when CT information is not likely to be of significance for treatment planning.

  20. Computed tomography, lymphography, and staging laparotomy: correlations in initial staging of Hodgkin disease

    Energy Technology Data Exchange (ETDEWEB)

    Castellino, R.A.; Hoppe, R.T.; Blank, N.; Young, S.W.; Neumann, C.; Rosenberg, S.A.; Kaplan, H.S.

    1984-07-01

    One hundred twenty-one patients with newly diagnosed, previously untreated Hodgkin disease underwent abdominal and pelvic computed tomographic (CT) scanning and bipedal lymphography. These studies were followed by staging laparotomy, which included biopsy of the liver, retroperitoneal and mesenteric lymph nodes, and splenectomy. Correlation of the results of the imaging studies with the histopathologic diagnoses revealed a small - but significant - increased accuracy of lymphography compared with CT in assessing the retroperitoneal lymph nodes. The theoretical advantages of CT scanning in detecting lymphomatous deposits in lymph nodes about the celiac axis and the mesentery, or in the liver and spleen, were not confirmed.

  1. Indirect caudal lymphography using a new water-soluble contrast agent - animal experimental studies in pigs

    International Nuclear Information System (INIS)

    Apitzsch, D.E.; Kroll, H.U.; Zuehlke, H.V.

    1981-01-01

    Animal experiments on caudal lymphography in pigs are presented, using a new water-soluble contrast medium which is renally excreted. Indirect cutaneous administration renders possible the radiological visualization of the entire lymphatic drainage system of the lower limb, the retro-peritoneal space and the thoracic duct. Visualization of the lymphatic system is rapid, homogeneous and can be repeated as often as desired. The quality of the lymphogram is as good as that obtained by the current methods in common use. (orig.)

  2. Animal experimental studies of indirect lymphography of the eye, face and neck regions using iotasul

    International Nuclear Information System (INIS)

    Wenzel-Hora, B.I.; Siefert, H.M.; Gruentzig, J.

    1982-01-01

    In experiments in the dog, it is possible to demonstrate the lymph drainage system of the conjunctiva and lids as far as the jugular trunk by means of indirect administration of the water-soluble contrast medium lotasul and application of a pressure bandage. Quicker opacification of th cervical lymph nodes can be achieved by simultaneous indirect lymphography (SIL) which also includes the chin region. (orig.)

  3. Primary lower limb lymphoedema. Classification with non-contrast MR lymphography

    Energy Technology Data Exchange (ETDEWEB)

    Arrive, Lionel; Derhy, S.; El Mouhadi, S.; Monnier-Cholley, L.; Menu, Y. [Saint-Antoine Hospital, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Sorbonne Universites, UPMC Universite Paris 06, Faculte de Medecine Pierre et Marie Curie, Paris (France); Dahan, B. [Cochin Hospital, Department of Emergency Medicine, Paris (France); Becker, C. [HEGP, Department of Thoracic Surgery, Paris (France)

    2018-01-15

    The purpose of the present study was to analyse the performance of non-contrast MR lymphography for the classification of primary lower limb lymphoedema in 121 consecutive patients with 187 primary lower limb lymphoedemas. 121 consecutive patients with clinically diagnosed primary lower limb lymphoedema underwent non-contrast MR lymphography with a free-breathing 3D fast spin-echo sequence with a very long TR/TE (4000/884 ms). MR examinations were retrospectively reviewed for severity of lymphoedema (absent, mild, moderate, severe) and characteristics of inguinal lymph nodes and iliac and inguinal lymphatic trunks graded as aplasic (no lymph nodes or lymphatic trunks), hypoplasic (less lymph nodes or lymphatic trunks), normal and hyperplasic (more lymph nodes or more and/or dilated trunks). There was an excellent correlation between clinical stage and severity of lymphoedema (Cramer's V of 0,73 (p < 0.001)). Differentiation was feasible between inguinal lymphatic vessel aplasia (21%), hypoplasia (15%), normal pattern (53%) and hyperplasia (11%). Severe lymphoedema was observed in 46% of aplasic patterns and in 37% of hyperplasic patterns, but in only 15% of hypoplasic patterns and never observed in normal patterns (p < 0.001). Non-contrast MR lymphography is able to classify primary lower limb lymphoedemas into hyperplasic, aplasic, hypoplasic and normal patterns. (orig.)

  4. Lymphography and computed tomography in the assessment of lymphnode invasion by bladder cancer. Comparison of diagnostic value

    International Nuclear Information System (INIS)

    Leguay, O.; Bellin, M.F.; Richard, F.; Mallet, A.; Grellet, J.

    1989-01-01

    The diagnostic value of lymphography and computed tomography (CT) in the assessment of lymph node invasion by bladder cancers has been compared on the basis of 30 observations. Although computed tomography apparently yields better results (reliability: 93%) than lymphography (reliability: 87%), these findings have no statistical significance. The study of literature shows that the statistical exploitation of the results was seldom carried out. The combination of both exploration techniques seems to improve predictive values, but this improvement was not statistically significant in the study [fr

  5. Lymphography with percutaneous fine needle cytology for the detection of malignant lymph node involvement

    International Nuclear Information System (INIS)

    Fencl, P.; Mylbachr, L.; Neradov, M.; Starek, J.; Doleckova, M.

    1988-01-01

    The authors present their experience of lymphograpy and percutaneous fine needle cytological biopsy of 60 patients with malignancies. Cytological specimens were taken from 98 lymph nodes in patients with cervical cancer (36), vulvar cancer (2), uterine sarcoma (2), vesical cancer (2), prostate gland cancer (3), Hodgkin's lymphoma (4), non Hodgkin's lymphoma (6), seminoma (4), lung cancer (1). Malignant cells were found in 31 persons in 41 nodes. Half of the dubious lymphography nodes had malignant cells in the biopsy material. Curiously enough, the contrast medium causes granulomatous inflammation of time-dependent intensity. 3 refs.; 2 figs.; 2 tabs

  6. Involvement of the thoracic duct in liver cirrhosis patients with ascites. Using MR lymphography

    International Nuclear Information System (INIS)

    Kuboyama, Shin-ichi; Ishii, Kunihide; Koga, Hiroyuki

    2003-01-01

    To elucidate whether the morphological changes of the thoracic duct are observed in patients with liver cirrhosis and ascites, the thoracic duct was examined at magnetic resonance (MR) lymphography without contrast agent. In 7 healthy volunteers, the thoracic duct was clearly visualized as an intermittent or continuous straight line along the thoracic aorta (its mean diameter was 3.9 mm). In 20 liver cirrhosis without ascites, its mean diameter was 3.6 mm. In 6 liver cirrhosis with refractory ascites, the thoracic duct was visualized as straight or slightly tortuous and slender line (its mean diameter was 2.5 mm). On the other hand, 7 cases with ascites which respond well to the administration of diuretics showed tortuous and dilated thoracic duct (its mean diameter was 4.3 mm). In cases with refractory ascites, mean diameter of the thoracic duct was significantly reduced, compared with the cases without ascites and with ascites that respond well to the administration of diuretics. Thus, it was found that the morphological differences of the thoracic duct depend on the response to the diuretics in liver cirrhosis patients with ascites. To elucidate whether the morphological changes of the thoracic duct are observed in patients with liver cirrhosis and ascites, the thoracic duct was examined at magnetic resonance lymphography without contrast agent. In cases with refractory ascites, mean diameter of the thoracic duct was significantly reduced, compared with the cases without ascites and with ascites that respond well to the administration of diuretics. (author)

  7. An experimental study on MR lymphography with various iron colloid agents

    Energy Technology Data Exchange (ETDEWEB)

    Okuhata, Yoshitaka (Nihon Univ., Tokyo (Japan). School of Medicine)

    1992-08-01

    Magnetic resonance (MR) lymphography with iron colloid agents was evaluated in an animal model. The agents examined were ferric gluconate (FeG), saccharated ferric oxide (SFO), iron chondroitin sulfate (ICS) and cideferron (CiF), which were used as intravenous medication for iron deficiency anemia. The author performed time-dose-response and correlative histologic studies. MR images of the popliteal lymph nodes of rabbits were obtained at 1.5 T with a spin-echo sequence (TR=300, TE=30 msec) before and after subcutaneous injection of the agents to dorsal hind-feet. The images were evaluated by signal intensity (SI). Histologic specimens were evaluated for distribution and relative quantity of stained iron with a color image analyzer. The SI with FeG 4 mgFe increased by 50% at 5 to 60 minutes after injection but returned to the pre-contrast level 48 hours later. The SIs with SFO 8 mgFe, ICS 1 mgFe and CiF 1 mgFe decreased to the background level at 60 minutes and 48 hours after injection. The histologic study in combination with the images indicated that in case of FeG the particles in lymph increased SI while in the other agents those within macrophages decreased SI. Because the agents are already used clinically, they can be safety applied to MR lymphography. (author).

  8. Direct lymphography and lower mesentericography - possibilities and limits in determining the localization, stage and operability of rectal cancer

    International Nuclear Information System (INIS)

    Viyachki, I.; Todorova, L.

    1976-01-01

    The indications for direct lymphography and lower mesentericography in determining the localization, stage and operability of rectal cancer are discussed in detail. Direct lymphography was attempted in 23 and lower selective mesentericography in 12 patients with rectal cancer. Essential is only the positive result, although it indicates an advanced malignant process. Lower mesentericography, especially the selective one, furnishes valuable information on the localization and stage of rectal cancer, and hence on its operability. Major importance is attached to the combined use of the two methods. They may thus complement one another in the diagnosis of the early stages of rectal cancer and may be helpful in the search of early recurrences after radical treatment. (author)

  9. Evaluation of MR lymphography with positive lymphotropic contrast agent in diagnosing lymph node lesions

    International Nuclear Information System (INIS)

    Zhou Zhengyang; Yu Haiping; Chen Junkun; Zhu Bin

    2010-01-01

    Objective: To evaluate the interstital MR lymphography using positive lymphotropic contrast agent for differentiation of metastatic lymph nodes from inflammatory lymph nodes hyperplasm. Methods: Eighteen New Zealand white rabbits weighted at 2. 0-2. 5 kg were used. Inflammatory hyperplastic popliteal lymph node model was established in 9 rabbits by injection of complete freund adjuvant into the interdigitial skin of the dorsal aspect of one hind leg, and tumor-bearing popliteal lymph node model was established in another 9 rabbits by injection of VX2 tumor cell suspension. The popliteal lymph nodes of another hind leg of all 18 rabbits were assigned to the normal contral group. In each group, every rabbit underwent MR lymphography examination before and after the inoculation. Volumes of 0.2 ml of Gd [ DTPA-bis ( 2-aminoethoxy ) ethane ] polymeric contrast agent ( Gd-poly-DTPA-EOEA ) injection were injected subcutaneously into the dorsal feet of both hind legs of two groups of rabbits. T 1 -weighted 3D gradient-echo images were obtained, and source images were used to reconstruct images of MIP before and after the administration of agent. The maximum short-axis diameter (MSAD) of each popliteal lymph node was measured on the enhanced 3D MIP images, and the signal-to-noise ratio (SNR) measurement was performed in the largest popliteal node of each rabbit at each time point in delayed scan. Independent- samples t test was used to compare the sizes of popliteal nodes in MSADs between inflammatorily hyperplastic and tumor-bearing nodes after the inoculation, and the values of SNRs of popliteal nodes at each time point between inflammatorily hyperplastic, tumor-bearing and normal popliteal lymph nodes. Imaging results of the popliteal nodes were analyzed and correlated with pathological findings. Results: All of the rabbits were successfully inoculated except of the 2 rabbits in tumor-bearing nodal group. The size in MSAD of 13 inflammatorily hyperplastic and 11 tumor

  10. Indirect Lymphography and its Importance in Oncology; La Lymphographie Indirecte et son Interet en Oncologie; Kosvennaya limfografiya i ee znachenie v onkologii; La Linfografia Indirecta y su Interes en Oncologia

    Energy Technology Data Exchange (ETDEWEB)

    Delaloye, B.; Magnenat, P. [Laboratoire des Radioisotopes, Clinique Medicale Universitaire de Lausanne, Lausanne (Switzerland)

    1964-10-15

    Indirect lymphography, which only requires a subcutaneous injection of colloidal gold-198 with a particle diameter of 50 A in the tributary region of the lymphatic system being explored, makes possible, by scintigraphic recording, a clear representation of the ganglionic lymphatic chains. The problems of collimation in getting optimum definition are discussed. With this method of investigating the lymphatic system, measurement of the time of appearance of the gold in the blood yields indirect information regarding the rate of transit of the colloidal gold particles in the lymphatic vessels. Useful information is also obtained on neoplastic infiltrations of the ganglia and hence it is possible to determine the extent of a metastatic infiltration. Clinical examples are described. In addition, the authors describe a new technique for hepatic lymphography by the transcutaneous, sub-capsular injection of colloidal gold-198. This technique reveals the anterior and posterior mediastinal lymphatic chains. (author) [French] La lymphographie indirecte, qui ne necessite qu'une injection sous-cutanee d'or-198 colloiedal dont le diametre des particules est de 50 Adans le territoire tributaire du systeme lymphatique que l'on veut explorer, permet par enregistrement scintigraphique une bonne mise en evidence des chaines ganglionnaires lymphatiques. Les problemes de collimation sont discutes afin d'obtenir la meilleure definition possible. Ce mode d'investigation du systeme lymphatique permet, lorsqu'on mesure le temps d'apparition de l'or dans le sang, d'obtenir indirectement des renseignements sur la vitesse du transit des particules d'or colloiedal dans les vaisseaux lymphatiques. On obtient egalement d'utiles renseignements sur les infiltrations neoplastiques des ganglions et, de ce fait, il est possible de connaitre l'etendue d'une infiltration metastatique. Des exemples cliniques sont decrits. De plus, les auteurs decrivent une nouvelle technique de lymphogtaphie hepatique

  11. The evaluation of multi-structure, multi-atlas pelvic anatomy features in a prostate MR lymphography CAD system

    Science.gov (United States)

    Meijs, M.; Debats, O.; Huisman, H.

    2015-03-01

    In prostate cancer, the detection of metastatic lymph nodes indicates progression from localized disease to metastasized cancer. The detection of positive lymph nodes is, however, a complex and time consuming task for experienced radiologists. Assistance of a two-stage Computer-Aided Detection (CAD) system in MR Lymphography (MRL) is not yet feasible due to the large number of false positives in the first stage of the system. By introducing a multi-structure, multi-atlas segmentation, using an affine transformation followed by a B-spline transformation for registration, the organ location is given by a mean density probability map. The atlas segmentation is semi-automatically drawn with ITK-SNAP, using Active Contour Segmentation. Each anatomic structure is identified by a label number. Registration is performed using Elastix, using Mutual Information and an Adaptive Stochastic Gradient optimization. The dataset consists of the MRL scans of ten patients, with lymph nodes manually annotated in consensus by two expert readers. The feature map of the CAD system consists of the Multi-Atlas and various other features (e.g. Normalized Intensity and multi-scale Blobness). The voxel-based Gentleboost classifier is evaluated using ROC analysis with cross validation. We show in a set of 10 studies that adding multi-structure, multi-atlas anatomical structure likelihood features improves the quality of the lymph node voxel likelihood map. Multiple structure anatomy maps may thus make MRL CAD more feasible.

  12. Sentinel nodes identified by computed tomography-lymphography accurately stage the axilla in patients with breast cancer

    International Nuclear Information System (INIS)

    Motomura, Kazuyoshi; Sumino, Hiroshi; Noguchi, Atsushi; Horinouchi, Takashi; Nakanishi, Katsuyuki

    2013-01-01

    Sentinel node biopsy often results in the identification and removal of multiple nodes as sentinel nodes, although most of these nodes could be non-sentinel nodes. This study investigated whether computed tomography-lymphography (CT-LG) can distinguish sentinel nodes from non-sentinel nodes and whether sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. This study included 184 patients with breast cancer and clinically negative nodes. Contrast agent was injected interstitially. The location of sentinel nodes was marked on the skin surface using a CT laser light navigator system. Lymph nodes located just under the marks were first removed as sentinel nodes. Then, all dyed nodes or all hot nodes were removed. The mean number of sentinel nodes identified by CT-LG was significantly lower than that of dyed and/or hot nodes removed (1.1 vs 1.8, p <0.0001). Twenty-three (12.5%) patients had ≥2 sentinel nodes identified by CT-LG removed, whereas 94 (51.1%) of patients had ≥2 dyed and/or hot nodes removed (p <0.0001). Pathological evaluation demonstrated that 47 (25.5%) of 184 patients had metastasis to at least one node. All 47 patients demonstrated metastases to at least one of the sentinel nodes identified by CT-LG. CT-LG can distinguish sentinel nodes from non-sentinel nodes, and sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. Successful identification of sentinel nodes using CT-LG may facilitate image-based diagnosis of metastasis, possibly leading to the omission of sentinel node biopsy

  13. Magnetic Resonance Lymphography Findings in Patients With Biochemical Recurrence After Prostatectomy and the Relation With the Stephenson Nomogram

    International Nuclear Information System (INIS)

    Meijer, Hanneke J.M.; Debats, Oscar A.; Roach, Mack; Span, Paul N.; Witjes, J. Alfred; Kaanders, Johannes H.A.M.; Lin, Emile N.J.Th. van; Barentsz, Jelle O.

    2012-01-01

    Purpose: To estimate the occurrence of positive lymph nodes on magnetic resonance lymphography (MRL) in patients with a prostate-specific antigen (PSA) recurrence after prostatectomy and to investigate the relation between score on the Stephenson nomogram and lymph node involvement on MRL. Methods and Materials: Sixty-five candidates for salvage radiation therapy were referred for an MRL to determine their lymph node status. Clinical and histopathologic features were recorded. For 49 patients, data were complete to calculate the Stephenson nomogram score. Receiver operating characteristic (ROC) analysis was performed to determine how well this nomogram related to the MRL result. Analysis was done for the whole group and separately for patients with a PSA <1.0 ng/mL to determine the situation in candidates for early salvage radiation therapy, and for patients without pathologic lymph nodes at initial lymph node dissection. Results: MRL detected positive lymph nodes in 47 patients. ROC analysis for the Stephenson nomogram yielded an area under the curve (AUC) of 0.78 (95% confidence interval, 0.61-0.93). Of 29 patients with a PSA <1.0 ng/mL, 18 had a positive MRL. Of 37 patients without lymph node involvement at initial lymph node dissection, 25 had a positive MRL. ROC analysis for the Stephenson nomogram showed AUCs of 0.84 and 0.74, respectively, for these latter groups. Conclusion: MRL detected positive lymph nodes in 72% of candidates for salvage radiation therapy, in 62% of candidates for early salvage radiation therapy, and in 68% of initially node-negative patients. The Stephenson nomogram showed a good correlation with the MRL result and may thus be useful for identifying patients with a PSA recurrence who are at high risk for lymph node involvement.

  14. The use of indocyanine green lymphography for the treatment of postoperative chylothorax with lipiodol lymphangiography in a 2-year-old child

    Directory of Open Access Journals (Sweden)

    Motoi Kato

    2017-08-01

    Full Text Available Postoperative chylothorax in infants prolongs hospital stay and possibly causes developmental delay because of its conservative treatment including inanition. Several medical and surgical treatments may be applied, but none constitute the absolute solution. Treatment with lipiodol during lymphangiography for postoperative chylothorax has been reported to be highly effective and less invasive in adults. On the other hand, few cases have been reported in infants. We demonstrate successful blockage of chyle leakage with lipiodol injection through the inguinal lymph node in a 2-year-old infant. The patient had undergone on-pump coarctectomy and chylothorax developed soon after surgery. Several medical treatments were partially effective, but the chest tube could not be removed because sequential aspiration was required to maintain a normal respiratory status. With the patient under general anesthesia, lipiodol injection combined with indocyanine green (ICG lymphography was performed. Lymphography combined with ICG significantly contributed not only to intraoperative detection of the inguinal lymph nodes but also to postoperative early detection of lymphedema caused by this procedure. This procedure required a simple maneuver and is probably applicable to other cases of traumatic chylothorax, such as after surgeries on the esophagus, trachea, or other components of the posterior mediastinum.

  15. Microsurgery guided by sequential preoperative lymphography using {sup 68}Ga-NEB PET and MRI in patients with lower-limb lymphedema

    Energy Technology Data Exchange (ETDEWEB)

    Long, Xiao; Gao, Chao; Yang, Elan [Peking Union Medical College Hospital Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Plastic Surgery, Beijing (China); Zhang, Jingjing [Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Nuclear Medicine, Beijing (China); National Institute of Biomedical Imaging and Bioengineering (NIBIB), National Institutes of Health (NIH), Laboratory of Molecular Imaging and Nanomedicine LOMIN, Bethesda, MD (United States); Zhang, Daming; Xue, Huadan [Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiology, Beijing (China); Chi, Chongwei [Institute of Automation Chinese Academy of Sciences Beijing, Key Laboratory of Molecular Imaging of Chinese Academy of Sciences, Beijing (China); Lang, Lixin; Niu, Gang; Chen, Xiaoyuan [National Institute of Biomedical Imaging and Bioengineering (NIBIB), National Institutes of Health (NIH), Laboratory of Molecular Imaging and Nanomedicine LOMIN, Bethesda, MD (United States); Zhu, Zhaohui; Li, Fang [Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Nuclear Medicine, Beijing (China)

    2017-08-15

    The popularity of contemporary microsurgical techniques in treatment of lower-limb lymphedema calls for better visualization of the lymphatic system, both preoperatively and intra-operatively. The aim of this prospective study was to investigate the feasibility of a novel combination of {sup 68}Ga-NEB positron emission tomography (PET) with magnetic resonance lymphography (MRL) in evaluating lymphedema and guiding surgical intervention. A total of 11 patients (F 9, M 2, age range 29-69 y) with lower-limb lymphedema classified into stage I to III were recruited. PET acquisition was performed at 30, 60 and 90 min after subcutaneous injection of the albumin-binding radiotracer {sup 68}Ga-NEB into the bilateral first web spaces of the feet. All the patients were also subjected to {sup 99m}Tc-sulfur colloid (SC) lymphoscintigraphy for comparison. Gd-DTPA-enhanced magnetic resonance imaging (MRI) was performed using sequences specialized for lymphatic vessel scans. All the patients underwent surgical interventions within a week. The surgical approach includes the use of a linear marker for edema localization and indocyanine green (ICG) lymphography with a near-infrared surgical navigation system intra-operatively. Lymph transport in lymphatic channels was clearly observed by visualization of {sup 68}Ga-NEB activity in the lymphatic vessels and within lymph nodes for all 11 patients as well as the visualization of the edema section plane with dermal backflow (DB), abnormally increased and disconnected uptake along the lymphatic channels. Preoperative {sup 68}Ga-NEB PET combined with MRL provides advantageous three-dimensional images, higher temporal resolution, significantly shorter time lapse before image acquisition after tracer injection and more accurate pathological lymphatic vessel distribution than {sup 99m}Tc-SC lymphoscintigraphy combined with MRI. This study documented an effective imaging pattern to combine {sup 68}Ga-NEB PET and MRL in patients with lower

  16. Lymphography and computed tomography of abdominal nodes in newly diagnosed patients with Hodgkin's disease in clinical stage I-III

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, C.H.

    1986-10-01

    Between 1978 and 1983, 80 patients with Hodgkin's disease (HD) in clinical Stage I-III had computed tomography (CT) of the abdomen and pelvis and lymphography (LAG) prior to staging laparatomy with multiple lymph node biopsies at Stanford University Medical Center. There were 224 biopsied nodal sites. The sensitivity and specificity for CT to determine the status of biopsied paraortic and iliac nodes was .61 and .91 vs. .94 and .90 for LAG. CT appeared of even lower sensitivity (.13) in evaluating splenic hilar, celiac axis and portal nodes. Including all biopsy proven subdiaphragmatic nodal sites, CT's sensitivity to diagnose the presence of subdiaphragmatic adenopathy was .38 vs. .52 in LAG. Assessment of the final pathological stage was more successful by LAG (.61) than by CT (.49). Positive and negative predictive values of both tests indicate higher reliability of LAG results as regards individual intraabdominal nodes (LAG .71, .98 vs. CT .58, .86), the entire subdiaphragmatic nodal area (LAG .79, .77 vs. CT .61, .71) and prediction of final pathological stage. LAG appeared to be the more useful test during initial staging of newly diagnosed and untreated patients with HD. None of the test for itself or in combination can replace laparatomy when exact information is necessary for further clinical decisions.

  17. Observation of the lymph flow in the lower extremities of edematous patients with noninvasive methods. RI-lymphography with a computer onlined gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Isao; Hirota, Akio; Watanabe, Sumio (Toho Univ., Tokyo (Japan). School of Medicine)

    1983-09-01

    An RI-lymphography with a computer onlined gamma camera was used for observing the lymph flow of edematous patients without any invasive procedures and for estimating the active movement of lymph vessels. Subjects were composed of 8 normal volunteers (group 1), 41 non-edematous patients (group 2) and 26 edematous patients (group 3). Four mCi of Tc-99m-HSA in a volume of 0.1 ml was injected subcutaneously in the pretibial region of the lower extremity, and immediately after the injection scintigram was recorded on the thigh every 5 sec. for 30 min. Results: 1) Normal volunteers; Time-activity curves showed a gradual increase in RI activity in relation to time without remarkable spike-like fluctuations. The maximum count attained was less than 200 cps in all experiments. 2) Non-edematous patients; In 46 out of 57 experiments (80.8%), the similar time-activity curves were observed as those of the normal volunteers. On the other hand, time-activity curves in 11 out of 57 (19.2%) showed a much steeper stepwise-increase simultaneously with remarkable spike-waves. The maximum count was over 200 cps in these cases. 3) Edematous patients; In 12 out of 35 experiments (34.3%), the maximum count was over 200 cps. In these edematous diseases other than lymphedema and hyperthyroidism, time-activity curves showed a rapid stepwise increase with a lot of spikes, and the maximum count was over 500 cps in 6 experiments. In 23 out of 35 (65.7%), the maximum count was less than 200 cps. In these cases, edema was attributable to secondary lymphedema, hypothyroidism, aging and so on. 4) Relationship between edema and lymph flow: When subjects were divided into 3 groups (non-edema, mild and severe edema), the maximum count 200 cps was observed in 16.7% in non-edema group, 45.8% in mild and 9.1% in severe edema group.

  18. Lymphography in chylothorax and chylous ascites

    International Nuclear Information System (INIS)

    Rabkin, I.Kh.; Lein, A.P.

    1982-01-01

    Sixteen lymphographic studies were made in patients with chylothorax and chylous ascites, which were spontaneous in 14 cases. Disseminated and limited lymphatic system lesions were revealed. Abundant lesions were mostly presented by multiple cysts and lymphangiectasia. Meanwhile solitary cysts, lymphangiomas, wall defects were detected in limited lesions. Lymphographic semiotics for chylothorax and chylous ascites has been developed. Direct signs of damage to the lymph vessels are classified with the most valuable symptoms: radiographic agent extravasation, the contrast substance congestion in the lesion area, its concentration in the pleural or abdominal cavities

  19. MR lymphography with macromolecular Gd-DTPA compounds

    International Nuclear Information System (INIS)

    Hamm, B.; Wagner, S.; Branding, G.; Taupitz, M.; Wolf, K.J.

    1990-01-01

    This paper investigates the suitability of macromolecular Gd-DTPA compounds as signal-enhancing lymphographic agents in MR imaging. Two Gd-DTPA polylysin compounds and Gd-DTPA albumin, with molecular weights of 48,000,170,000, and 87,000 daltons, respectively, were tested in rabbits at gadolinium doses of 5 and 15 μmol per animal. Three animals were examined at each dose with T1-weighted sequences. The iliac lymph nodes were imaged prior to and during unilateral endolymphatic infusion into a femoral lymph vessel as well as over a period of 2 hours thereafter. All contrast media showed a homogeneous and pronounced signal enhancement in the lymph nodes during infusion at both doses

  20. Lymphatic imaging: Lymphography, computed tomography and scintigraphy, 2nd ed

    International Nuclear Information System (INIS)

    Close, M.E.; Wallace, S.

    1985-01-01

    The latest addition to the Golden's Diagnostic Radiology series deals not only with imaging of the lymphatic system but also with lymphatic anatomy, its pathophysiology, and treatment of disorders. The first two chapters deal with the history of the discovery of the lymphatic system and its normal anatomy. The section on technique contains practical information and discussion of lymphatic physiology and the pathology of lymphomas. Half of the book's 16 chapters are devoted to problems encountered in clinical imaging. The approach is both by anatomy (thorax, neck, abdomen) and pathology (benign disease, lymphoma, solid tumors)

  1. Evaluation of a new component used for isotopic lymphography: colloidal rhenium sulfide sup(99m)Tc labelled

    International Nuclear Information System (INIS)

    Pecking, A.; Le Mercier, N.; Gobin, R.; Bardy, A.; Najean, Y.

    1978-01-01

    We have studied for lymphatic scintigraphy a new radiopharmaceutical, sup(99m)Tc-labelled rhenium sulfocolloid. This preliminary study includes 20 adults patients with lymphomas and lymphoedemas. The principal advantage of this drug is its absence of toxicity and local pain, so that a rapid sub-cutaneous injection without local anesthesia is made possible. Good results have been obtained, as well in morphological studies of para-aortic and mammary lymph nodes as for kinetic studies of lymphatic flow in lymphoedemas. No liver and spleen uptake of radio-isotope was observed after foot injection [fr

  2. Foot skin depots of 18F-fluorodeoxyglucose do not enable PET/CT lymphography of the lower extremity lymphatic system in man

    DEFF Research Database (Denmark)

    Jensen, Mads Radmer; Simonsen, Lene; Lonsdale, Markus

    2013-01-01

    consecutive PET scans of the same region.Blood activity increased faster and to a greater extent in the great saphenous veins compared to the medial cubital vein. PET/CT images showed activity in the superficial and deep veins of the lower extremities. No lymphatic collectors or nodes were visualized....... CONCLUSION: Neither subcutaneous nor intradermal injection of 18F-FDG allows imaging of the lower extremity lymphatic system in man....

  3. Visualization of the thoracic duct by lymphoscintigraphy

    International Nuclear Information System (INIS)

    Baulieu, F.; Baulieu, J.L.; Itti, R.; Tours Univ., 37

    1987-01-01

    Imaging of the thoracic duct is usually performed by radiological lymphography. However, this procedure, which uses an oil based dye injected directly into the lymph channels, has some adverse effects. In this paper we note that lymphoscintigraphy, a physiological and non invasive method, may visualize thoracic duct abnormalities, and might be particularly usefull when radiological lymphography is contraindicated. (orig.)

  4. Direct lymphangiography as treatment option of lymphatic leakage: Indications, outcomes and role in patient's management

    Energy Technology Data Exchange (ETDEWEB)

    Gruber-Rouh, Tatjana, E-mail: tgruberrouh@googlemail.com [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Naguib, Nagy N.N. [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Department of Radiology, Faculty of Medicine, Alexandria University, Alexandria (Egypt); Lehnert, Thomas; Harth, Marc; Thalhammer, Axel; Beeres, Martin [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Tsaur, Igor [Department of Urology, Johann Wolfgang Goethe University Frankfurt, Frankfurt am Main (Germany); Hammersting, Renate; Wichmann, Julian L.; Vogl, Thomas J.; Jacobi, Volkmar [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2014-12-15

    Background: To evaluate the effectiveness of lymphography as a minimally invasive treatment option of lymphatic leakage in terms of local control and to investigate which parameters influence the success rate. Method: This retrospective study protocol was approved by the ethic committee. Patient history, imaging data, therapeutic options and follow-up were recorded and retrospectively analyzed. Between June 1998 and February 2013, 71 patients (m:w = 42:29, mean age, 52.4; range 42–75 years) with lymphatic leakage in form of lymphatic fistulas (n = 37), lymphocele (n = 11), chylothorax (n = 13) and chylous ascites (n = 10) underwent lymphography. Sixty-four patients (90.1%) underwent successful lymphography while lymphography failed in 7 cases. Therapeutic success was evaluated and correlated to the volume of lymphatic leakage and to the volume of the applied iodized oil. Result: Signs of leakage or contrast extravasation were directly detected in 64 patients. Of 64 patients, 45 patients (70.3%) were treated and cured after lymphography. Based on the lymphography findings, 19 patients (29.7%) underwent surgical intervention with a completely occlusion of lymphatic leakage. The lymphatic leak could be completely occluded in 96.8% of patients when the lymphatic drainage volume was less than 200 mL/day (n = 33). Even when lymphatic drainage was higher than 200 mL/day (n = 31), therapeutic lymphography was still successful in 58.1% of the patients. Conclusion: Lymphography is an effective, minimally invasive method in the detection and treatment of lymphatic leakage. The volume of lymphatic drainage per day is a significant predictor of the therapeutic success rate.

  5. Direct lymphangiography as treatment option of lymphatic leakage: Indications, outcomes and role in patient's management

    International Nuclear Information System (INIS)

    Gruber-Rouh, Tatjana; Naguib, Nagy N.N.; Lehnert, Thomas; Harth, Marc; Thalhammer, Axel; Beeres, Martin; Tsaur, Igor; Hammersting, Renate; Wichmann, Julian L.; Vogl, Thomas J.; Jacobi, Volkmar

    2014-01-01

    Background: To evaluate the effectiveness of lymphography as a minimally invasive treatment option of lymphatic leakage in terms of local control and to investigate which parameters influence the success rate. Method: This retrospective study protocol was approved by the ethic committee. Patient history, imaging data, therapeutic options and follow-up were recorded and retrospectively analyzed. Between June 1998 and February 2013, 71 patients (m:w = 42:29, mean age, 52.4; range 42–75 years) with lymphatic leakage in form of lymphatic fistulas (n = 37), lymphocele (n = 11), chylothorax (n = 13) and chylous ascites (n = 10) underwent lymphography. Sixty-four patients (90.1%) underwent successful lymphography while lymphography failed in 7 cases. Therapeutic success was evaluated and correlated to the volume of lymphatic leakage and to the volume of the applied iodized oil. Result: Signs of leakage or contrast extravasation were directly detected in 64 patients. Of 64 patients, 45 patients (70.3%) were treated and cured after lymphography. Based on the lymphography findings, 19 patients (29.7%) underwent surgical intervention with a completely occlusion of lymphatic leakage. The lymphatic leak could be completely occluded in 96.8% of patients when the lymphatic drainage volume was less than 200 mL/day (n = 33). Even when lymphatic drainage was higher than 200 mL/day (n = 31), therapeutic lymphography was still successful in 58.1% of the patients. Conclusion: Lymphography is an effective, minimally invasive method in the detection and treatment of lymphatic leakage. The volume of lymphatic drainage per day is a significant predictor of the therapeutic success rate

  6. Chapter 20. Lymphatic system

    International Nuclear Information System (INIS)

    Meyniel, G.; Plagne, R.; Veyre, A.

    1975-01-01

    It is recalled than in isotopic lymphography the tracer may be introduced into the lymphatic system by two methods: direct lymphography when the product is injected directly into a lymphatic vessel or lymph node, indirect lymphography when the product is injected into interstitial tissues, taken up by the lymph flow and fixed by the glands. The disadvantages of the direct method at present restrict the radioisotopic exploration of the lymphatic system to indirect lymphography. This technique, whereby the lymphatic draining of the tracer injection zone may be followed, is described. The use of metallic colloids (Au-198, In-111, Tc-99m) fixed by the glands gives a sharp and lasting contrast, but also possesses disadvantages. The conditions required of a selective tracer are examined and the possibilities of various types of molecules for this study estimated. In spite of undeniable disadvantages the colloids of technetium-99m are being used more and more because of the quality of the images obtained. The results are interpreted and the chief indications of the method defined. The therapeutic possibilities of isotopic lymphography are also shown [fr

  7. Limphographic characteristics of the metastases in cancer of the urinary bladder

    International Nuclear Information System (INIS)

    Baldzhijski, A.; Panchev, V.; Simeonov, I.

    1984-01-01

    A total of 887 pedal lymphographies have been performed, 178 of them (173 men and 5 women) in a search for metastases of bladder cancer. Lymphography showed positive result for metastases in 110 patients (61,71 per cent); in 58 patients it was evaluated as negative for metastases (32,58 per cent) and in 9 (5,63 per cent) gave equivocal result. Most frequently affected were the iliac lywph groups, thf first barrier - 100 per cent involvement in proven metastases. Next in incidence of involvement (second barrier) were the paraortal lymphgroups - 55,45 per cent. Te external iliac inguinal groups were the ones most seldom affected

  8. VIIth international symposium on nuclear medicine

    International Nuclear Information System (INIS)

    1983-01-01

    The conference proceedings contain abstracts of 100 presented papers, mainly dealing with radioimmunoassays, radiopharmaceuticals, scintiscanning, computer tomography, radionuclide lymphography, ventriculography, angiography, nuclear cardiology, liquid scintillator techniques, radioisotope generators, radiospirometry and various uses of labelled compounds and tracer techniques in nuclear medicine. (M.D.)

  9. Czechoslovak congress of radiology with international participation

    International Nuclear Information System (INIS)

    1986-01-01

    The booklet contains 125 abstracts of papers presented at the congress, dealing with diagnostic and therapeutic applications of X-rays, 60 Co, 137 Cs, betatron radiation, with scintigraphy, angiography, lymphography, with radiosensitizers, contrast media and with a host of activities performed and results achieved at radiological departments. (A.K.)

  10. Radiology of metastases to the minor pelvis

    International Nuclear Information System (INIS)

    Weigert, F.; Rohde, U.; Lindner, P.

    1985-01-01

    Reviewing the literature and summarizing our own experience, the role of various imaging modalities concerning diagnosis of metastases to lymph nodes and organs in the pelvic cavity is discussed. Especially ultrasound, CT and lymphography are compared, the importance of fine-needle-aspiration is emphasized. Possible advantages of MRI are mentioned. (orig.) [de

  11. The prevention of the primary lymphedema

    International Nuclear Information System (INIS)

    Benda, K.; Lebloch, D.; Bendova, M.

    1998-01-01

    The endangered familiar members of the ailing with the primary lymphedema are clinically examined (anamnesis, physical examination of the extremities and biochemical examination) and by radionuclide lymphography of the extremities. For the proved latent stadium of the lymphedema the complex of preventive therapy is recommended. (authors)

  12. Factors Associated with Lower Extremity Dysmorphia Caused by Lower Extremity Lymphoedema.

    Science.gov (United States)

    Yamamoto, T; Yamamoto, N; Yoshimatsu, H; Narushima, M; Koshima, I

    2017-07-01

    Indocyanine green (ICG) lymphography has been reported to be useful for the early diagnosis of lymphoedema. However, no study has reported the usefulness of ICG lymphography for evaluation of lymphoedema with lower extremity dysmorphia (LED). This study aimed to elucidate independent factors associated with LED in secondary lower extremity lymphoedema (LEL) patients. This was a retrospective observational study of 268 legs of 134 secondary LEL patients. The medical charts were reviewed to obtain data of clinical demographics and ICG lymphography based severity stage (leg dermal backflow [LDB] stage). LED was defined as a leg with a LEL index of 250 or higher. Logistic regression analysis was used to identify independent factors associated with LED. LED was observed in 106 legs (39.6%). Multivariate analysis revealed that independent factors associated with LED were higher LDB stages compared with LDB stage 0 (LDB stage III; OR 17.586; 95% CI 2.055-150.482; p = .009) (LDB stage IV; OR 76.794; 95% CI 8.132-725.199; p < .001) (LDB stage V; OR 47.423; 95% CI 3.704-607.192; p = .003). On the other hand, inverse associations were observed in higher age (65 years or older; OR 0.409; 95% CI 0.190-0.881; p = .022) and higher body mass index (25 kg/m 2 or higher; OR 0.408; 95% CI 0.176-0.946; p = .037). Independent factors associated with LED were elucidated. ICG lymphography based severity stage showed the strongest association with LED, and was useful for evaluation of progressed LEL with LED. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Radiology today

    International Nuclear Information System (INIS)

    Donner, M.W.; Heuck, F.H.W.

    1981-01-01

    The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)

  14. A conservative approach to a thoracic duct injury caused by left subclavian vein catheterization

    OpenAIRE

    Vedran Premuzic; Ranko Smiljanic; Drazen Perkov

    2018-01-01

    Thoracic duct injury is a rare complication of left subclavian vein catheterization. A significant injury could lead to chylothorax, a condition with high mortality rate if not treated. It is diagnosed with lymphography or by laboratory tests of pleural fluid aspirate. A 51 year old Caucasian male with a history of unregulated hypertension presented to our Emergency department (ED) with anginous symptoms and increased serum creatinine level. After the placement of a temporary central venous c...

  15. Gammascintigraphy of metastases of the lymph nodes

    International Nuclear Information System (INIS)

    Mechev, D.S.; Shishkina, V.V.

    1985-01-01

    It was indicated that according to the degree of informative value all the methods used in this study can be listed as follows: the method of combined use of positive and negative scintigraphy, the method of positive scintigraphy with Ga 67 -citrate (the tymph nodes above the diagram) and Tc 99 -pertechnate (the lymph nodes below the diaphragm), the method of indirect radionuclide lymphography with colloids. The main indices of radionuclide methods in the diagnosis of the lymph node metastatic involvement are presented

  16. Topics in clinical oncology. 15

    International Nuclear Information System (INIS)

    Cepcek, P.

    1987-12-01

    The monograph comprising primarily papers on topical subjects of oncology and cancer research, contains also a selection of papers presented at the 2. Congress of the Czechoslovak Society of Nuclear Medicine and Radiation Hygiene. Seven papers were selected on behalf of their subject related to clinical oncology. All of them were iputted in INIS; five of them deal with the scintiscanning of the skeleton of cancer patients, one with radioimmunodetection of tumors, and one with radionuclide lymphography. (A.K.)

  17. Mediastinal lymphoscintigraphy after intraperitoneal injection of 99mTc-HSA-D

    International Nuclear Information System (INIS)

    Kawahara, Hidejirou; Hirai, Katsuya; Aoki, Teruaki; Takayama, Sumio; Mori, Yutaka

    1998-01-01

    An intraperitoneal injection tube was inserted into the abdominal cavity (right subphrenic lesion 3, left subphrenic lesion 3, Douglas pouch 3) in patients with recurrent gastric cancer and those receiving non curative resection. 99m Tc-HSA-D, 1 ml (740 MBq) was administered through the tube. After the injection, lymph flow dynamics was observed with a scinticamera. In the subphrenic injection group, there was no significant difference in the mediastinal lymphography between right and left subphrenic injection. In that group, mediastinal lymphography had been observed promptly after the administration. However, in the Douglas injection group, until 99m Tc-HSA-D reached the diaphragm no mediastinal lymphography was observed. The HSA-D count in the peripheral blood increased in the Douglas injection group but it remained low in the subphrenic injection group. Therefore it is conceivable that the main pathway was the diaphragm lymphatic system between the intraabdominal lymphatic system and the mediastinal lymphatic system. And intraperitoneal administration of the anticancer agent may not only have a sufficiently effect on the intraabdominal lymphatic system but also on the mediastinal lymphatic system. Especially subphrenic injection is very useful because concentration of the agent in peripheral blood may be held at a low level. (author)

  18. Radiologic techniques in staging malignant lymphoma

    International Nuclear Information System (INIS)

    Strijk, S.P.

    1987-01-01

    The main subject of this thesis is the evaluation of radiologic techniques in staging patients with newly diagnosed and untreated malignant lymphoma, or restaging patients with recurrent disease after a period of complete remission. Lymphography and, more recently, CT are available to examine the infradiaphragmatic nodes. CT also offers the possibility to examine other organ systems in the abdomen, and to visualize more lymph-node regions than lymphography. In ch. 2 and 4 the diagnostic performance of CT and lymphography in HD and NHL respectively are discussed. Literature data are summarized, and own results are given. The main goal is to determine whether the two methods are overlapping, competitive or complementary, and to answer the question what would be required for optimal staging. Staging laparotomy showed the unreliability of non-invasive examination methods for determining the presence or absence of lymphoma in the spleen. In ch. 3 and 5 the results of CT-based estimations of size of the spleen in relation to its histologic state, in patients with HD and NHL respectively are presented. The chest can be examined for lymphoma by conventional radiography, conventional tomography or computed tomography (CT). In ch. 6 the literature is reviewed, and the results with our patients are presented. The diagnostic performance of each examination is evaluated, and the results are analysed to define the most desirable approach in the examination of the chest for staging purposes. In ch. 7 the uncommon radiologic observation of calcification in lymph nodes, afflicted with HD and NHL is described. The literature is reviewed, and the clinical significance is indicated. 180 refs.; 22 figs.; 24 tabs

  19. Prefabricated Cervical Skin Flaps for Hemi-Facial Resurfacing: Elucidating the Natural History of Postoperative Edema Using Indocyanine Green.

    Science.gov (United States)

    Li, Ke; Min, Peiru; Sadigh, Parviz; Grassetti, Luca; Lazzeri, Davide; Torresetti, Matteo; Marsili, Riccardo; Feng, Shaoqing; Liu, Ningfei; Zhang, Yi Xin

    2018-02-01

    The increases in capillary wall permeability and capillary hydrostatic pressure are considered to be the causes for the acute swelling seen in flaps; however, disruption of the circulating flap lymphatics could be another contributory factor. In this study we monitor the development of flap edema in a series of 18 prefabricated flaps and aim to delineate the natural history of this phenomenon by use of lymphography. Postoperative swelling was monitored in a series of 18 pre-expanded prefabricated cervical skin flaps used for hemi-facial burns-scar resurfacing. Time to spontaneous resolution, presence or absence of venous congestion, and clinical outcome were recorded. In two cases, indocyanine-green (ICG) lymphography was used to monitor the dermal backflow pattern until swelling had completely resolved. Average moving velocity of ICG after injection as well as flap thickness was also recorded over the follow-up period. The average moving velocity of ICG in the flap lymphatics improved from 0.48 cm/min to 1.5 cm/min in the first 12 days after flap transfer. The dermal backflow pattern was stardust in the first 12 days, indicating moderate lymphedema, transforming to splash from week three, and a robust collecting lymphatic vessel occurring from the fifth month, indicating mild lymphedema and lymphatic channel recovery, respectively. Transient swelling was observed in all prefabricated flaps in our series. We postulate that this is mostly secondary to lymphatic disruption that subsides as lymphangiogenesis takes place. ICG lymphography is an inexpensive, safe, and easy-to-use imaging technology that could be used in the monitoring of postoperative lymphedema seen in prefabricated flaps.

  20. Lymphographic criteria of lymphatic edema of the limbs in terms of microsurgery

    International Nuclear Information System (INIS)

    Rabkin, I.Kh.; Krylov, V.S.; Milanov, N.O.; Lein, A.P.; Ermakov, N.P.

    1980-01-01

    Based on the assessment of the results of 126 lymphographic studies, performed on patients with lymphatic edema of the limbs of various genesis, an important role has been assigned to lymphography as the criterion for establishing indications and contra-indications for microsurgical lymphovenous anastomosis. A special technique of pre-operation lymphophlebographic examination of patients with lymphatic edema of the limbds has been developed. A working scheme of primary lymphatic edemas, as well as the detailed interpretation of lymphographic appearance of primary and secondary lymphatic edemas are also provided

  1. Characteristics of lymphographic semiotics in children with Hodgkin's disease

    International Nuclear Information System (INIS)

    Baryshnikov, V.L.; Krivenko, Eh.V.; Minkh, N.V.

    1984-01-01

    Direct low lymphography was performed in 140 children aged 2.5 to 16 wheh Hodgkin's disease. Typical changes in the lymph nodes were found in 45 (32.14%) patient;. Symptoms of disordered drainage function of the nodes in children occur more frequently than in adults (in 71% of the cases observed). X.ray signs of the morphological changes in the lymph nodes that in combination with functional symptoms give 4 main symptomocomplexes which are characteristic of Hodgkin's disease in children are singled out

  2. Normal anatomy of the lymphatic system in the CT-image

    International Nuclear Information System (INIS)

    Steinbrich, W.; Peters, P.E.

    1982-01-01

    To evaluate a pathologic process of a lymphatic node, detailed knowledge is required of the normal anatomy of the lumphatic system in an axial CT image. The anatomy is demonstrated in a comparative study before and after lymphography with CT-scans of patients with normal lymphadenographs. Hereby it appears that with the high-resolution scanning method and favourable imaging conditions even small lymphatic nodes can be differentiated without a lymphographic contrast technique. However, nerves and vessels cannot be differentiated. The extreme variability in the size of normal lymphatic nodes makes the differentiation of pathologic processes very difficult. (orig.) [de

  3. Soft tissue tumors - imaging methods

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1985-01-01

    Soft Tissue Tumors - Imaging Methods: Imaging methods play an important diagnostic role in soft tissue tumors concerning a preoperative evaluation of localization, size, topographic relationship, dignity, and metastatic disease. The present paper gives an overview about diagnostic methods available today such as ultrasound, thermography, roentgenographic plain films and xeroradiography, radionuclide methods, computed tomography, lymphography, angiography, and magnetic resonance imaging. Besides sonography particularly computed tomography has the most important diagnostic value in soft tissue tumors. The application of a recently developed method, the magnetic resonance imaging, cannot yet be assessed in its significance. (orig.) [de

  4. Urologic imaging and interventional techniques

    International Nuclear Information System (INIS)

    Bush, W.H.

    1989-01-01

    This book provides an overview of all imaging modalities and invasive techniques of the genitourinary system. Three general chapters discuss ionic and nonionic contrast media, the management of reactions to contrast media, and radiation doses from various uroradiologic procedures. Chapters are devoted to intravenous pyelography, computed tomography, magnetic resonance imaging, ultrasound, nuclear medicine, lymphography, arteriography, and venography. Two chapters discuss the pediatric applications of uroradiology and ultrasound. Two chapters integrate the various imaging techniques of the upper and lower genitourinary systems into an algorithmic approach for various pathologic entities

  5. Clinico-lymphographic diagnosis of post-traumatic edema

    International Nuclear Information System (INIS)

    Chepelenko, G.V.

    1989-01-01

    Clinico-lymphographic comparisons in various manifestations of posttraumatic edema are presented. Early and delayed stages of chronic lymph flow violations are singled out. Data on distal non-progressing edema above foot edema following bone fractures in the low third of shank, in case of chronic edema of various limb segments occuring on the back-ground of muscle tissue atrophy are given. A clinico-lymphographic classification of posttraumatic edema is developed. Some new information on the value of lymphography in assessment of lymphographic lumen in bone defects, its substitution and elongation is reported

  6. Preclinical studies of lymphographic applilcation of 99mTc-dextrans of different molecular weight

    International Nuclear Information System (INIS)

    Lamka, J.; Kvetina, J.; Kafka, P.

    1986-01-01

    In a preclinical investigation on rabbits the distribution was tested of dextrans of two molecular weights (40,000 and 70,000) with regard to their use as a carrier in indirect lymphography. The tests showed that both 99m Tc-dextrans achieve high ratios of lymph/blood levels. It is suggested that for clinical work it is better to use dextran with a molecular weight of 70,000 than that with a molecular weight of 40,000. (author)

  7. The application of the bilateral collimator to parasternal lymphoscintigraphy: a new method to measure the depth of the lymph node

    International Nuclear Information System (INIS)

    Ohtake, E.; Toyama, H.; Iio, M.; Noguchi, M.; Kawaguchi, S.; Murata, H.; Chiba, K.; Yamada, H.

    1980-01-01

    The bilateral collimator has been widely adopted for obtaining two simultaneous views of the heart in nuclear cardiology. As an additional useful clinical application of the bilateral collimator, it has been used for parasternal lymphoscintigraphy. Lymphography with a contrast medium for the parasternal lymphatics is technically very difficult and the radionuclide method is adopted. Lymphoscintigraphy has been used in order to determine the existence of malignant invasion to the lymph nodes, and also to find the depth of the lymph node as a guide to operation and radiation therapy of the nodes. (author)

  8. Nodal lymphomas of the abdomen

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Caramella, E.; Manzino, J.J.

    1986-01-01

    Modern imaging modalities have greatly contributed to current knowledge about intra-abdominal nodal lymphomas. Since both intra and retroperitoneal node involvement can be demonstrated by computed tomography (CT) and ultrasonography, it seems legitimate to treat these two sites together in the same chapter, particularly since the older separation between intraperitoneal and retroperitoneal nodal disease was based to a large degree on the limitations of lymphography. Hodgkin's disease (HD) has benefited less from recent technological advances. The diversity in the incidence of nodal involvement between HD and NHL, the diagnostic capabilities of modern imaging techniques, and the histopathological features of lymphomatous non-Hodgkin and Hodgkin nodes, justify adoption of an investigatory approach which takes all of these factors into account. Details of this investigative strategy are discussed in this paper following a review of available imaging modalities. In current practice, the four main methods for the exploration of abdominal lymph nodes are lymphography, ultrasonography, CT, and radionuclide studies. The first three techniques are also utilized to guide biopsies for staging purposes and for the evaluation of response to treatment

  9. Les indications de la biopsie de foie dans le bilan d'extension de la maladie de Hodgkin

    OpenAIRE

    Rémond Pla , Anne

    2000-01-01

    Non disponible / Not available; Le bilan d'extension lors de la maladie de Hodgkin s'est considérablementsimplifié depuis les années 1970. La biopsie de foie reste un des deux seulsexamens invasifs, avec la lymphographie bipédieuse.Il nous a paru intéressant, en l'absence de consensus sur ce point, de définir àquelles indications doit être réservée la biopsie.Au terme de notre étude rétrospective et à partir des données de la littérature,il nous semble que la seule indication valable soit de ...

  10. Roentgenoradionuclide study of the liver lymphatic system (the development of the method and criteria for the evaluation of extravascular plasma flow)

    Energy Technology Data Exchange (ETDEWEB)

    Tatochenko, K V; Morgunov, N B; Uskov, I A [Pervyj Moskovskij Meditsinskij Inst. (USSR)

    1984-05-01

    An attempt was made to develop an instrumental method for the evaluation of the extravascular plasma flow (lymph flow) of the liver. Ultrasonography of the liver does not give an opportunity to differentiate between different states including those accompanied by the excess lymph discharge into the liver. The results of intraparenchymal lymphography of the liver were analysed in patients with and without biliary and portal hypertension. 11 criteria have been singled out that make it possible to judge an elevated production of the lymph in the liver. A method of ''radioangiolymphography'' of the liver based on the administration of diffusing and nondiffusing radiopharmaceuticals in the afferent vessels of the liver was worked out. Variation in the parameters of the radionuclide circulation seems to reflect significantly extrahepatic circulation in the liver and holds great promise for the use in hepatology.

  11. A conservative approach to a thoracic duct injury caused by left subclavian vein catheterization

    Directory of Open Access Journals (Sweden)

    Vedran Premuzic

    2018-01-01

    Full Text Available Thoracic duct injury is a rare complication of left subclavian vein catheterization. A significant injury could lead to chylothorax, a condition with high mortality rate if not treated. It is diagnosed with lymphography or by laboratory tests of pleural fluid aspirate. A 51 year old Caucasian male with a history of unregulated hypertension presented to our Emergency department (ED with anginous symptoms and increased serum creatinine level. After the placement of a temporary central venous catheter for hemodialysis in left subclavian vein, he developed lymph leakage on puncture site beside the catheter, at drainage rate of 75 ml/h. In the absence of more serious clinical symptoms, conservative treatment with close patient monitoring and diet changes was chosen, rather than more invasive treatment options.

  12. Detection of endotoxins in radiopharmaceutical preparations. III. Limulus test assessment using radiopharmaceutical preparations; correlation with the rabbit pyrogen test

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Y; Bahri, F; Bruneau, J; Dubuis, M; Dubuis, N; Merlin, L; Michaud, T; Peysson, S

    1986-01-01

    Experiments using 17 radiopharmaceuticals containing known amounts of added endotoxin show that none of them inhibits the pyrogenic reaction of the rabbit. Gelation of the Limulus amoebocyte lysate (LAL) is inhibited by 4 of them: colloidal erbium 169Er citrate, colloidal rhenium 186Re sulfide, colloidal technetium /sup 99m/Tc (Re) sulfide for liver scintigraphy and the colloidal technetium /sup 99m/Tc (Re) sulfide for lymphography. This inhibition is cancelled, either by dilution or after neutral pH adjustment. Both controls were performed on 313 batches of various radiopharmaceuticals, 95% of results were identical (93% negative, 2% positive). The remaining 5% correspond to positive LAL tests vs negative rabbit tests on the same batches. No negative LAL test vs positive rabbit test was observed.

  13. How size evaluation of lymph node is protocol dependent in MRI when using ultrasmall superparamagnetic iron oxide nanoparticles

    International Nuclear Information System (INIS)

    Gharehaghaji, Nahideh; Oghabian, Mohammad Ali; Sarkar, Saeed; Darki, Fahimeh; Beitollahi, Ali

    2009-01-01

    In this study, the volume of susceptibility artifact was evaluated in T1 and T2-weighted spin echo (SE) and gradient echo (GRE) images at various parameters using registration and subtraction methods. In order to state an important misinterpretation problem in lymphography, it was demonstrated that a lymph node size may be enlarged approximately 10 times when a T2*-weighted GRE protocol is used. To overcome this problem a technical consideration using multisequence (GRE and SE) paradigm was suggested to ensure both lymph node detection and metastasis identification in lymphatic system. The paradigm was also extended by post-processing manipulation of the SE images using a registration and subtraction approach for detection of lymphatic lesions.

  14. Primary disorders of the lymphatic vessels--a unified concept.

    Science.gov (United States)

    Levine, C

    1989-03-01

    Congenital defects of lymphatics constitute a spectrum of disorders that may manifest with a variety of clinical presentations including lymphedema, chylous effusions, lymphangiomatous malformations with cystic masses and localized gigantism, and intestinal lymphangiectasia with malabsorption. These entities constitute a relatively rare group of disorders, the origin of which remains somewhat controversial, but in some it appears to be due to early lymphatic obstruction. Five cases are described, which demonstrate the anatomical pathology of these entities. A classification and description of the defects is also presented. An attempt is made to present a unified theory of origin for this seemingly diverse group of diseases. While these entities may be challenging from a diagnostic and therapeutic standpoint, a wide variety of imaging modalities, which includes lymphography, computed tomography scanning, and ultrasound, may be used to diagnose the extent and internal structural characteristics of the abnormalities.

  15. Accuracy of abdominal lymph node scintigraphy in tumor diagnostics

    International Nuclear Information System (INIS)

    Kucharczyk, D.

    1978-01-01

    In view of the diagnostical correspondence between lymph node scintigraphy and X-ray lymphograpy, this dissertation, which is based on 110 systematic comparative evaluations, examines the diagnostical weight of the scintigraphic criteria for tumor growth, discusses diagnostical discrepancies and confirms the efficacy of lymph node scintigraphy in detecting malignomas. In discussing the diagnostical results in the light of previous experience, the shortcomings of the nuclear medical method in tumor diagnostics are shown to be attributable to the uncertainty of the individual scintigraphic criteria. Owing to the variability of the lymph node system as to topography, anatomy and retention rate and the fact that it cannot morphologically be well differentiated in the scintigram, X-ray lymphography to verify the scintigraphic result and preclude misinterpretation remains an indispensable measure. (orig.) [de

  16. Determination of the anatomic borders of the irradiation area for cervical and corporal carcinomas

    International Nuclear Information System (INIS)

    Moeller-Kuhlmann, G.

    1980-01-01

    Intention of the present study was to refer the silhouettes of the irradiation field to anatomically definite osseous structures. For this examination the caudal, cranial and the lateral borders were marked by different methods and their position with respect to the corresponding osseous structures was detected. For documenting the soft-tissue structures the following techniques could be applied: lymphography, hysterosalpingography, vaginal contrasting and computerized tomography. The evaluation of the obtained results showed that the dorsal silhouette ranges between the 4th and 5th lumbar vertebrae, that the lateral silhouette reaches the middle of the head of the femur and that the caudal one includes the obturator. The detection and definition of the target area for curative radiotherapy of corporal and cervical carcinomas can therefore renounce on the contrast representation of soft-tissue organs. On the contrary it is even possible to adjust the irradiation field with the therapy simulator under consideration of anatomically fixed osseous structures. (orig./MG) [de

  17. Regional lymphadonectomy in uterine cervix carcinoma patients after radiotherapy

    International Nuclear Information System (INIS)

    Bokhman, Ya.V.; Kuznetsov, V.V.

    1981-01-01

    A group of patients with uterine cervix carcinoma with metastatic indices in regional lymphatic vessels detected on lymphograms is studied. It is established that after radiation treatment the relative resistance of lymphogenic metastases to the ionizing radiation is found in 14.9% patients. Extraperitoneal removal of regional lymphatic collectors after a complete course of combined radiation therapy in patients with uterine cervix carcinoma with histologically proved metastases improves 3-year results of survival up to 40%. In the case of multiple and bilateral metastatic injury of regional lymph nodes the therapeutic value of extraperitoneal lymphadenectomy reduces sharply. The diagnostic value of X-ray contrast lymphography not only for defining regional metastases, but for planning and carrying out the treatment of patients with uterine cervix carcinoma is pointed out [ru

  18. Roentgenoradionuclide study of the liver lymphatic system (the development of the method and criteria for the evaluation of extravascular plasma flow)

    International Nuclear Information System (INIS)

    Tatochenko, K.V.; Morgunov, N.B.; Uskov, I.A.

    1984-01-01

    An attempt was made to develop an instrumental method for the evaluation of the extravascular plasma flow (lymph flow) of the liver. Ultrasonography of the liver does not give an opportunity to differentiate between different states including those accompanied by the excess lymph discharge into the liver. The results of intraparenchymal lymphography of the liver were analysed in patients with and without biliary and portal hypertension. 11 criteria have been singled out that make it possible to judge an elevated production of the lymph in the liver. A method of ''radioangiolymphography'' of the liver based on the administration of diffusing and nondiffusing radiopharmaceuticals in the afferent vessels of the liver was worked out. Variation in the parameters of the radionuclide circulation seems to reflect significantly extrahepatic circulation in the liver and holds great promise for the use in hepatology

  19. Assessment of organ doses by standard X-ray procedures in the GDR

    International Nuclear Information System (INIS)

    Tautz, M.; Brandt, G.A.

    1986-01-01

    A modern method has been described to assess the radiation burden by X-ray procedures with consideration of the standards of our Society for Medical Radiology in the GDR. The underlying methodology is a Monte Carlo computer technique, which simulates stochastically the energy deposition of X-ray photons in a mathematically described heterogeneous anthropomorphic phantom by Rosenstein (US Department of Health, Education and Welfare). To apply the procedure specific values for the following parameters must be determined for each dose estimation: projection and view, X-ray field size and location entrance exposure at skin surface, beam quality, source-to-image receptor distance. The base data are obtained in terms of tissue-air ratio. Organ doses were calculated for chest, urography, skull, cervical spine, thoracic spine, lumbar spine, pelvis and lymphography. Concluding possibilities have been discussed for reduction of radiation burden. 9 refs., 6 figs., 9 tabs. (author)

  20. Central high signal in inflammatory swollen lymph nodes on SPIO-enhanced interstitial MR lymphograms. A mimic of lymph node metastasis

    International Nuclear Information System (INIS)

    Suzuki, Daisuke; Yamaguchi, Masayuki; Furuta, Toshihiro; Fujii, Hirofumi; Okuyama, Yasuo; Yoshikawa, Kohki

    2012-01-01

    This study demonstrates that the central high signal which has been considered to be useful for the differential diagnosis of inflammation and metastasis in SPIO (super-paramagnetic iron oxide)-enhanced interstitial MR lymphography, is observable even in the simple inflammation of the lymph node (LN),. Lymphadenitis was induced by injection of Freund's complete adjuvant in the foot pad of 10 ddY mice, where ferucarbotran (a clinical SPIO agent) at 0.17 micro-moles Fe/foot in 6 mice or the control saline in 4 mice was administered 2 weeks later. Lipid-suppressed T2-weighted fast-spin-echo images (T2WIs) were acquired (retention time/effective echo time 4000/60 ms: resolution 78 x 78 x 1000 micro-m 3 ) of the popliteal LN in vivo and ex vivo using 3T whole body scanner (Signa HDx) with a radiofrequency coil dedicated to mice. Areas of high signal crossing the LN center on the in vivo transverse T2WIs were measured to evaluate non-enhanced areas quantitatively. Iron deposit in LNs was evaluated by Prussian blue staining. In mice given SPIO, the mean area of high signal was 3.9 mm 2 vs 11.3 in those given the saline, low signal in the periphery in 6/6 mice vs 0/4, ex vivo low signal in the whole area in 1 case vs 0 and periphery in 5 cases vs 0, and iron deposit in the whole in 2 cases vs 0 and periphery in 4 cases vs 0, respectively. The finding indicates that a central high signal in swollen sentinel LNs in clinical SPIO-enhanced interstitial MR lymphography with a high magnetic field does not always mean the presence of metastatic foci. (T.T.)

  1. Technological evolution of axillary lymph nodes: Radiological visualisation in breast cancer patients

    International Nuclear Information System (INIS)

    Eglitis, J.; Krumins, V.; Stengrevics, A.; Berzins, A.; Vevere, I.; Storozenko, G.

    2004-01-01

    Full text: In patients with breast cancer, detection of axillary lymph node spread has a great prognostic significance. Visualisation of lymphatic glands is attracting attention of radiologists since long. Lymphogram usually shows 4-9 lymph glands as compared to 8 to 50 identified during surgical intervention. Lymphography is a laborious and complicated process requiring specific skills. Likewise, the evaluation and interpretation of results depends upon the experience of the specialist. We evaluated 234 breast cancer patients and found that lymphograms of these patients initially detected 1-2 central axillary lymph nodes followed by others. During surgical intervention, the total number of lymphatic glands removed from these patients was 3,241 of which only 2,693 (83.1%) were seen on lymphography. On further evaluation it was found that the largest groups of lymphatic nodes were seen in the following pattern (i) central axillary (ii) subclavicular (iii) lateral, with central axillary lymph nodes being the biggest (1.5 - 2 cm) and subclavicular the smallest (0.2 - 0.5 cm). Sternal lymph nodes receive lymph from medial quadrants of the breast and / or if the axillary lymph nodes are obstructed by metastases. The results of lymphography and post-operative examination matched in 71.7-75 % of cases. False positivity was seen in 19.2 % and false negative 9.1 % instances. As this method was not sufficiently selective and specific, its relative upsurge receded backwards and was forgotten. The last decade of the twentieth century saw a sentinel node (SN) concept. In advanced countries, the possibility to detect breast cancer of up to 1 cm diameter corresponding to T1A category, when the axillary lymph nodes still are not involved in malignant growth, accounts about 50%. Hence the search of lymphatic spread vis-a-vis sentinel node detection has gained more importance. Earlier, SN detection involved colour contrast methods, which was reasonably sensitive and specific in

  2. [Chylopericardium as a complication of cardiac surgery: report of two cases and review of the literature].

    Science.gov (United States)

    Velinović, Milos; Vranes, Mile; Kocica, Mladen; Djukić, Petar; Mikić, Aleksandar; Vukomanović, Vladislav; Kacar, Sasa; Putnik, Svetozar; Marković, Dejan; Seferović, Petar M

    2007-01-01

    Chylopericardium refers to existing communication between the pericardial sac and the thoracic duct carrying the chyle. The objective of our report was to highlight the specificity of diagnosis and treatment of this rare but tedious condition through the analysis of two case reports. Male patient, aged 63 years, with chylopericardium was diagnosed perioperatively (implantation of artificial aortic--St. Jude No 21 and mitral valve--St. Jude No 29). Etiology of pericardial effusion was established by Sudan III staining of punctate specimen obtained by subxiphoid pericardial puncture. Probable cause of chylopericardium was the lesion of ductus thoracicus during cross-clamping of the superior caval vein with a Cooley clamp. Initial treatment included diet rich in medium-chain triglycerides which resulted in resolution of the effusion. During five-year follow-up, there were no recurrences of pericardial effusion. The second patient was female, 21 years old, with chylopericardium after partial pericardiectomy performed because of the chronic severely symptomatic pericardial effusion, resistant to other forms of treatment. Pericardiocentesis provided 650 ml of yellowish fluid with a high concentration of cholesterol (3.2 mmol/l), triglycerides (16.6 mmol/l), and proteins (64.7 g/l), which verified chylopericardium, most probably as a consequence of the lesion of ductus thoracicus during partial pericardiectomy. Diet rich in medium-chain triglycerides failed to decrease the effusion, after two weeks of treatment (daily secretion 250-350 ml). Lymphography revealed lesion of ductus thoracicus, most probably at Th9/Th10 level, with no direct visualization of extravasal accumulation of contrast media. Surgical ligation of ductus thoracicus was performed through the right thoracotomy. However, postoperative secretion increased to 1000 ml/day. Patient underwent redo surgery comprising the ligation of lymphatic vessels, guided by extravasation of intraoperatively iwected

  3. A study of the area of paraaortic lymph nodes dissection in gastric cancer based on lymphatic flow of the stomach using radioactive isotope

    Energy Technology Data Exchange (ETDEWEB)

    Sasagawa, Tsuyoshi (Tokyo Women' s Medical Coll. (Japan))

    1992-04-01

    In gastric cancer patients, I subdivided paraaortic lymph nodes (No.16) into 4 zones. Using RI lymphography I analyzed the lymphatic flow from the cardiac and pyloric region to the No.16. Also, based on these results as well as studies of clinical lymph node metastasis, I elucidate the rational No.16 area in extended lymph node dissection. The lymphatic flows to the No.16 by RI lymphography showed the following routes. The route from the cardiac region was: (1) along the left gastric artery heading towards lymph node around the celiac artery and into the left/right No.16; (2) along the posterior gastric artery and splenic artery from lymph node around the splenic artery directly to the left No.16; (3) along the inferior phrenic artery from left cardiac lymph node and lymph node at the splenic hilus directly to the left upper No.16. The route from the pyloric region was: (1) along the common hepatic artery heading towards lymph node around the celiac artery to the left/right No.16; (2) from infrapyloric lymph node along the gastrocolic trunc flowing to lymph node at the root of the mesenterium and No.16. In upper gastric cancer, there was a high rate of metastasis to lymph node along the lesser curvature and right cardial lymph node, and lymph node along the left gastric artery and splenic artery. There were 3 cases in which metastasis was positive only to cardial lymph node and upper left No.16. In lower gastric cancer, there was a high rate of metastasis to infrapyloric lymph node, lymph node along the lesser curvature, lymph node along the left gastric artery and the common hepatic artery. In all cases which metastasized in group 4, the No.16 metastasis rate was significantly higher in the upper left No.16, being 84.8%. Given the above, the area of paraaortic lymph node dissection in extended lymph node dissection, irrespective of whether it is upper or lower gastric cancer, must be done in the 4 zones, and especially, the upper left No.16 is important. (author).

  4. Total lymphoid irradiation in the Wistar rat: technique and dosimetry

    International Nuclear Information System (INIS)

    Hoogenhout, J.; Kazem, I.; de Jong, J.

    1983-01-01

    The technical and dosimetric aspects of total lymphoid irradiation (TLI) in the Wistar rat were evaluated as part of a set-up to develop a new model for tumor xenotransplantation. Information obtained from anatomical dissections, radionuclide imaging of the spleen, lymphography and chromolymphography was used to standardize the localization portals cut out in a lead plate. The two portals encompassed the lymphoid tissue above and below the diaphragm. A specially designed masonite phantom was used to measure the dose distribution in the simulated target volumes. Ionization chamber dosimetery, thermoluminescence dosimetry and film densitometry were used for measuring exposure and absorbed dose. Irradiation was performed with 250 kV X rays (HVL 3.1 mm Cu). The dose rate was regulated by adjusting the treatment distance. The dose inhomogeneity measured in the target volumes varied between 80-100%. The side scatter dose to non target tissues under the shielded area between the two portals ranged between 20-30%. The technique and dosimetry of total lymphoid irradiation in Wistar rats are now standardized and validated and pave the way for tumor xenotransplantation experiments

  5. Lymphedema of the limbs. Isotopic lymphograhy

    International Nuclear Information System (INIS)

    Doucet, J.

    1978-01-01

    A new method, isotopic lymphography, is proposed as a simple means to estimate the real dynamics of lymphatic circulation, confirming or refuting the lymphoedema diagnosis. This simple and non-aggressive method does not require direct injection into a lymphatic and is therefore applicable whatever the state of the lymphatic circulation; labelled molecules injected into interstitial tissue are in fact drained by the lymphatic capillaries. - 0.5 ml of a sup(99m)Tc colloid solution is injected into the subcutaneous region of the first inter-digital space of each foot. - The product used is a polyvinylpyrolidone-stabilised antimony sulphate precolloid. The particle diameter is known to be an essential factor, governing tissular resorption, migration speed in the lymphatic network, impregnation of relays far from the injection point, degree of ganglionic granulopexy. In general a diameter below 50 A is desirable to avoid too much local stasis and allow the tracer to diffuse throughout the network. - The colloid is labelled with 2 to 3 mCi technetium sup(99m). Given the low activities injected and the physical characteristics of technetium sup(99m) the radiobiological risks are negligible. - The instrument used is a scintillation camera of which the detection head, placed above the two legs of the recumbent patient, explores the region between ankles and knees, then the thighs and finally the abdomen [fr

  6. An analysis of lymphographic signs for differentiating cancerous, lymphomatous, and normal lymph nodes

    International Nuclear Information System (INIS)

    Tatsuzaki, Hideo; Nakajima, Teiichi; Okumura, Toshiyuki; Akisada, Masayoshi

    1987-01-01

    Twenty-four lymphographic signs, obtained from a total of 204 cancerous (C), lymphomatous (L), and normal (N) lymph nodes, were analyzed based on the final diagnosis. Univariate analyses with correlation coefficient and multivariate regression analyses were employed to differentiate C, L, or N lymph nodes. Based on univariate analyses, lymphographic sings for C nodes were - enlarged node, irregular or deficient capsules or marginal sinuses, block of lymph vessels, extravasation, and defect in lymph-vascular and nodal phase (combination defect). The signs for L node were - enlarged node, elliptic shape from 2 projections, irregular or deficient capsules or marginal sinuses, and extravasation. Using multivariate analyses, the following signs were necessary for differentiating individual lymph nodes: (a) combination defect, specific pattern, granularity, nodal shape and stasis or preservation of lymph vessels for differentiating C from N nodes; (b) deficiencies of capsules, nodal shape, specific pattern, dislocation of lymph vessels, and nodal contrast for differentiating L from N nodes; and (c) character of defect, specific pattern, deformity, soft tissue shadow and nodal shape for differentiating C from L nodes. Should lymphography be used in the visualization of inside structure and lymphatic canal, it would even more increase the ability to diagnose cancer and malignant lymphomas. (Namekawa, K.)

  7. Understanding the three-dimensional anatomy of the superficial lymphatics of the limbs.

    Science.gov (United States)

    Tourani, Saam S; Taylor, G Ian; Ashton, Mark W

    2014-11-01

    There are minimal data in the current literature regarding the depth of the superficial lymphatic collectors of the limbs in relation to the various subcutaneous tissue layers. Injection, microdissection, radiographic, and histologic studies of the superficial lymphatics and the subcutaneous tissues of 32 limbs from 15 human cadavers were performed. Five layers were consistently identified in the integument of all the upper and lower limb specimens: (1) skin, (2) subcutaneous fat, (3) superficial fascia, (4) loose areolar tissue, and (5) deep fascia. Layer 2 was further divided into superficial (2a) and deep (2c) compartments by a thin, transparent, horizontal septum (layer 2b). The main superficial veins and the superficial nerves coursed in layer 4. The lymphatic collectors were found at layer 2c and layer 4. The use of consistent nomenclature to describe the subcutaneous tissue layers facilitates a greater understanding and discussion of the anatomy. In lymphovenous anastomosis for the treatment of lymphedema, indocyanine green lymphography is an unreliable method for identification of the superficial collectors of the thigh. The medial proximal leg, the dorsum of the wrist over the anatomical snuffbox, and the volar proximal forearm provide suitable areas for locating superficial collectors with nearby matching size veins. In vertical medial thigh lift, choosing a dissection plane superficial to the great saphenous vein is unlikely to preserve the collectors of the ventromedial bundle.

  8. Simultaneous utilization of different nuclear medical examinations in a patient with Klippel-Trenaunay syndrome - vs. proteus syndrome

    International Nuclear Information System (INIS)

    Rink, T.; Baum, R.P.; Hoer, G.; Menzel, I.; Niemczyk, M.; Kaufmann, R.; Fuchs, S.; Heller, K.

    1997-01-01

    A three-year-old male patient presented already at his birth a disproportional macrosomia of the left foot and a large, nodular nevus flammeus, in the left hip region, which led to the tentative diagnosis of a Klippel-Trenaunay syndrome. In the following years, both changes showed a continuous progression, with distinct soft-tissue swelling as well as papillomatous and verruciform vegetations of the nevus. Additionally, large, plain subcutaneous masses developed under the right shoulder, and a macrodactyly of the first and second left toe could be observed. Although several examinations had been performed in the meantime, the tentative diagnosis could not be confirmed up to that time. On the occasion of a severe local infection in the hip region, which led to the consideration of a surgical therapy, a radionuclide lymphography, a blood pool scintigraphy including dynamic phlebography and ventriculography as well as a bone scintigraphy were performed. These examinations were done simultaneously at one day in order to avoid a longer period of immobilization. The findings led to the diagnosis of a large lymphangioma, which could be confirmed histologically after surgery. In consideration of all results, the basic disorder seems to be the rare proteus syndrome rather than a Klippel-Trenaunay syndrome. (orig.) [de

  9. The present status in the clinical development of MR contrast media

    International Nuclear Information System (INIS)

    Laniado, M.; Kopp, A.F.

    1997-01-01

    The paramagnetic extracellular Gd contrast media (Gd-CM) Magnevist, Dotarem, Omniscan, and ProHance are on the market, whereas Gadovist, Optimark, and MultiHance (also used as a hepatobiliary CM) are undergoing clinical trials (phase III). Among other indications, Gd-CM are applied in tumours, inflammation, vascular pathologies, and MR-angiography. The paramagnetic hepatobiliary CM Teslascan, Eovist and MultiHance are in clinical trials (phase II and III). They improve tumour detection and characterisation. The Mn-CM Teslascan is also suited for pancreatic imaging, the Gd-CM MultiHance for imaging of myocardial infarction and the brain, and the Gd-CM Eovist has been used in liver CT. The superparamagnetic reticuloendothelial CM Endorem is on the market whereas Resovist is undergoing phase-III trials. Both agents have the same indications as the hepatobiliary CM. Sinerem is another superparamagnetic CM. However, it acts as a blood pool agent and accumulates in lymph nodes (MR lymphography). Gastrointestinal CM are divided into paramagnetic, superparamagnetic and diamagnetic agents acting either as positive or negative CM. Some are on the market, but their clinical value is limited. (orig.) [de

  10. Cost-analysis of staging methods for lymph nodes in patients with prostate cancer: MRI with a lymph node-specific contrast agent compared to pelvic lymph node dissection or CT

    International Nuclear Information System (INIS)

    Hoevels, Anke M.; Adang, Eddy M.; Heesakkers, Roel A.M.; Jager, Gerrit J.; Barentsz, Jelle O.

    2004-01-01

    The aim of this study was to compare the costs of three strategies in patients with prostate cancer in a specific setting: firstly, a strategy including MR lymphography (MRL) in which pelvic lymph node dissection (PLND) is foregone in case of a negative result. The second strategy involves computed tomography (CT) followed by a biopsy or PLND. The third strategy consists of PLND without imaging beforehand. A decision analytic model was constructed. This model represented the diagnostic process for patients with prostate cancer and intermediate or high risk for nodal metastases, comparing the costs of the three strategies. Cost analysis was done from the health care perspective. The model indicated that the expected costs for the MRL strategy were □2,527. The expected costs for the strategy using CT were □3,837 and for PLND □3,994. These results show that potential savings performing MRL instead of CT were □1,310 and □1,467 for PLND. Sensitivity analyses show that variation in costs of PLND was most influential on the costs of all strategies. However, the overall savings pattern did not alter. Average costs of MRL staging in our institution are less than for CT and PLND in staging lymph nodes of patients with prostate cancer and who are intermediate or high risk for nodal metastases. (orig.)

  11. Assessment of peripheral vessels and of the lymphatic system by means of gamma-camera scintiscan (gamma-scintigraphy of the whole body)

    Energy Technology Data Exchange (ETDEWEB)

    Ennis, J T

    1981-01-01

    For diagnosing pathologies of the peripheric vessels or of the lymphatic system, albumin aggregates marked with sup(99m) technetium (MAA) or antimonocolloids were used. The radionuclide venography is useful in diagnosing thrombosis, venous insufficiency, and permits a high degree of accuracy, comparable with that of phlebography. In the most cases the radionuclide lymphoscintigraphy is required for the diagnosis of lymphoedema and allows by distribution analysis an adequate morphological representation of the lymphatic ducts and glands. Contrary to lymphography, lymphoscintigraphy presents a completely physiological radionuclide transport and does not cause any reactive lymphatic node hyperplasia by contrast media. Increased capillary perfusion is found in collateral vessel formation in cases of arterial obstruction and ischaemic ulcus, whereas hypoperfusion is seen in obstructions of the larger arteries having no collateral vessels, and in bad circulatory states. Particularly in diabetics with microangiopathy, a peripheral distribution with hyperfusion of the skon presents itself as piece-meal necrosis. The importance and relevance of the perfusion scans of the extremities for the diagnostic assessment within the field of resection surgery is explained.

  12. A combined data mining approach using rough set theory and case-based reasoning in medical datasets

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Rezvan

    2014-06-01

    Full Text Available Case-based reasoning (CBR is the process of solving new cases by retrieving the most relevant ones from an existing knowledge-base. Since, irrelevant or redundant features not only remarkably increase memory requirements but also the time complexity of the case retrieval, reducing the number of dimensions is an issue worth considering. This paper uses rough set theory (RST in order to reduce the number of dimensions in a CBR classifier with the aim of increasing accuracy and efficiency. CBR exploits a distance based co-occurrence of categorical data to measure similarity of cases. This distance is based on the proportional distribution of different categorical values of features. The weight used for a feature is the average of co-occurrence values of the features. The combination of RST and CBR has been applied to real categorical datasets of Wisconsin Breast Cancer, Lymphography, and Primary cancer. The 5-fold cross validation method is used to evaluate the performance of the proposed approach. The results show that this combined approach lowers computational costs and improves performance metrics including accuracy and interpretability compared to other approaches developed in the literature.

  13. Carcinoma cervicis uteri. Long-term follow-up therapeutic results.

    Science.gov (United States)

    Ptácková, B; Kucera, F; Caha, A; Tacev, T; Spurný, V; Kabela, M; Konecný, M; Krystof, V

    1982-01-01

    The principle of the therapy of carcinoma cervicis uteri in the Research Institute of Clinical and Experimental Oncology in Brno is the combination of betatron megavoltage irradiation and cobalt 60 irradiation with intracavital radium irradiation. On the basis of many years' study concerning the therapy and therapeutic results of this tumor accurate directions of total therapy were elaborated. Carcinoma is diagnosed and classified precisely according to valid international directions. In addition to basic examination, limb lymphography was introduced giving the strategy of irradiation when lymphatic system is involved and in early stages of the disease. By preliminary evaluation of the obtained data a certain improvement of therapeutic results is proven. About 15% more patients are alive till 5 years without any signs of the disease than in precedent years. In spite of a high dose summation given by the extent of megavoltage irradiation the number of postirradiation reaction, nor early late, is increased to much. Complex therapy of this tumor is performed by a team of physicians composed of gynecologist, radiologist, rentgendiagnosticist, pathologist, and radiation physicist. By increasing the number of cured patients and their return and enclosure into further working process the savings in state budget are achieved. The effectiveness of the carcinoma cervicis uteri therapy is therefore dependent not only on earlier diagnosis and modern irradiation technique, but also on the cooperation of a team of physicians who plan, perform and follow the therapy.

  14. Lymphoscintigraphy and autologous stem cell implantation

    International Nuclear Information System (INIS)

    Peña, Yamile; Batista, Juan F.; Perera, Alejandro; Torres, Leonel A.; Sánchez, Elvia L.; Sánchez, Yolaine; Ducat, Luis; Prats, Anais; Hernández, Porfirio; Romero, Susana; Goicochea, Pedro; Quintela, Ana M.

    2016-01-01

    Lymphoscintigraphy is the criterion standard technique for the diagnosis of lymphedema. Advances of the application of autologous hematopoietic stem cells in ischemic disorders of lower limbs have increased the attention of researchers in this field. Aim: To determine the usefulness of lymphoscintigraphy for the assessment the efficacy of autologous stem cell implantation in patients with chronic lymphedema of the upper and lower limbs. Methods: Sixty-five patients were included. Clinical evaluation and lymphoscintigraphy were performed before and six months after stem cells implantation. The stem cells implantations were carried out by multiple superficial and deep injections in the trajectory of the lymphatic vessels and also in the inguinal region. A volume of 0.75 to 1.00 mL of cell suspension (1.0-2.2 x 109 stem cells) was administered in each injection site. Lymphoscintigraphy: Whole-body scans were acquired at 20 minutes, 1 hour, and 3 hours after administration of 185 to 259 MBq (5–7mCi) of 99m Tc-albumin nanocolloids in the interdigital space of both limbs. The anatomy and function of the lymphatic system were evaluated. Results: Functional assessment before implantation of stem cells showed that 69.2% of the patients had severe lymphatic insufficiency. The 61.5% of patients showed clinical improvement, confirmed by the results of the lymphoscintigraphy. The 46.1% of the cases evaluated showed a clear improvement. The study showed that the isotopic lymphography can evaluate the therapeutic response and its intensity. Conclusion: Lymphoscintigraphy is a useful technique for the evaluation and monitoring of autologous stem cell transplantation in patients with chronic lymphedema. (author)

  15. Radionuclide lymphoscintigraphy in the evaluation of peripheral edema

    International Nuclear Information System (INIS)

    Kim, Soon; Zeon, Seok Kil

    2000-01-01

    It has been difficulty to visualize lymphatics in living patients. Conventional or direct lymphography has been the gold standard for delineation of the lymphatic system, but this procedure is invasive, difficulty to perform, and harmful to the lymphatic vascular endothelium. The aim of our study was to determine its severity, and to understand the drainage patterns on patients with peripheral edema by functional lymphatic studies. Tc-99m antimony sulfide colloid 25 MBq with 0.4 ml volume was injected intradermally in the first, second and third web space of the foot or hand in 40 patients with peripheral edema (5 in upper extremity and 35 in lower extremity). Initial flow after injection and whole body images at approximately 30 minutes. 1-4 hours were obtained. In 9/40 cases with peripheral edema normal lymphoscintigram were revealed, primary lymphedema was observed in 5/31 cases. The imaging patterns in primary lymphedema were absent (3 cases) or delayed (2 cases) transport, lymphatic duct dilatation (1), cutoff (1), decrease in size and number of lymph nodes (2). The Common caused of edema in secondry lymphedema (26/31) were carcinoma (13), inflammation (5), post-operation (5), and unknown origin (3). The common imaging findings in carcinoma showed non-visualization of lymph nodes (13), dermal backflow (8), collateral circulation (5), and in inflammation lymphatic obstruction (2), increase in size and number of lymph nodes (2), delayed transport (1), and in post-operation dermal backflow (3), delayed transport (2), decrease in number and size of lymph node (2) Clear images patterns were observed difference between primary lymphedema an secondary lymphedema. Radionuclide lymphoscintigraphy is essentially non-invasive, easy to perform repeatedly, and harmless to the lymphatic vascular endothelium for evaluation of a patient with lymphedema

  16. Contribution of radioisotopic techniques to identify sentinel lymph-nodes (SLN) in breast cancer

    International Nuclear Information System (INIS)

    Zarlenga, Ana C.; Katz, Lidia; Armesto, Amparo; Noblia, Cristina; Gorostidi, Susana; Perez, Juan; Parma, Patricia

    2009-01-01

    The SLN (one or several) is the first to receive lymph from a tumor. When a cancer cell comes off the tumor and circulates along the outgoing lymph, it meets a barrier, the SLN that intercepts and destroys it. If not, the cancer cell can stay and reproduce in the SLN making a metastasis which can affect other nodes in the same way. It has been shown that if the original tumor is small there is little chance that the SLN could be invaded and therefore little chance of dissemination to other lymph-nodes. Nowadays due to early detection, breast tumors are smaller than one cm, therefore with such size there is little chance of axillary lymph-nodes being affected. If it is confirmed by histological study that the SLN is free of metastasis, it is not necessary to perform a axillary emptying. This identification of SLNs has been achieved because of the advances of Radioisotopic Techniques, which has been carried out in our Hospital since 1997. We have been adapting this technique to the national supply of equipment and radio compounds always under a reliable and secure way. The aim of this presentation is to highlight the radioisotopic identification of SLNs in clinical investigation in 'Angel H. Roffo Institute', and its daily practice compare with Positron Emission Tomography (PET). By combining Radioisotopic Lymphography, Lymphochromography and intra surgical detection of the SN with Gamma Probe, we have obtained a true negative value of 95% of the SN, with 5% false negative. Due to this method we have included SN study in daily practice breast tumor patients with tumor up to 5 cm of diameter. Comparing this methods result (5% false negative), with the PET results, using 18 F-FDG, that has 33% false negatives, we conclude that a negative result can not replace this method of SN detection. (author)

  17. Radionuclide studies of the lymphatic systems and their particular role in the assessment of the lymphoedema

    International Nuclear Information System (INIS)

    Zakkou, E.

    1984-01-01

    Dynamic radionuclide studies of the lymphatic system are used to measure the length of time required for the tracer to transit the upper and lower extremities as well as to determine, for any given point of time, the transportation and storage capacities of lymph vessels and nodes, respectively. Secondary lymphoedemas of more substantial proportions can reliably be diagnosed and classified on the basis of degrees of severity. The presence of those lymphoedemas is typically indicated by dermal back flow at circulatory bottlenecks, delays or marked delays (by more than 15 min) in transit and durations of transit beyond the measurable range. Further characteristic signs are passive dilatation of the prefacial bundle of lymph vessels (which is likely to be a first degree dilatation, if seen in late scintigrams and a second or third degree dilatation in cases escaping scintigraphic detection) and wide-spread inhibitions of activity over the entire extremity examined. Combined oedematous changes of lymph vessels and veins can only be predicted from lymph circulation disorders. This method permits an immediate diagnosis of any conditions precluding the use of endolymphatic therapy in malignant melanomas, thus sparing the patient the discomforts of treatment and helping to avoid unnecessary expenditure. Dynamic scintigraphy offers advantages over lymphography in that it has a greater discriminating power in diagnostic evaluations of active or passive dilatation of the bundle of lymph vessels, dermal back flow as well as the functional performance of damaged lymph vessels and also in that it permits a more precise visualisation of the superfacial and deep vessels of the lymphatic systems. (TRV) [de

  18. Imaging long-term fate of intramyocardially implanted mesenchymal stem cells in a porcine myocardial infarction model.

    Directory of Open Access Journals (Sweden)

    Emerson C Perin

    Full Text Available The long-term fate of stem cells after intramyocardial delivery is unknown. We used noninvasive, repetitive PET/CT imaging with [(18F]FEAU to monitor the long-term (up to 5 months spatial-temporal dynamics of MSCs retrovirally transduced with the sr39HSV1-tk gene (sr39HSV1-tk-MSC and implanted intramyocardially in pigs with induced acute myocardial infarction. Repetitive [(18F]FEAU PET/CT revealed a biphasic pattern of sr39HSV1-tk-MSC dynamics; cell proliferation peaked at 33-35 days after injection, in periinfarct regions and the major cardiac lymphatic vessels and lymph nodes. The sr39HSV1-tk-MSC-associated [(18F]FEAU signals gradually decreased thereafter. Cardiac lymphography studies using PG-Gd-NIRF813 contrast for MRI and near-infrared fluorescence imaging showed rapid clearance of the contrast from the site of intramyocardial injection through the subepicardial lymphatic network into the lymphatic vessels and periaortic lymph nodes. Immunohistochemical analysis of cardiac tissue obtained at 35 and 150 days demonstrated several types of sr39HSV1-tk expressing cells, including fibro-myoblasts, lymphovascular cells, and microvascular and arterial endothelium. In summary, this study demonstrated the feasibility and sensitivity of [(18F]FEAU PET/CT imaging for long-term, in-vivo monitoring (up to 5 months of the fate of intramyocardially injected sr39HSV1-tk-MSC cells. Intramyocardially transplanted MSCs appear to integrate into the lymphatic endothelium and may help improve myocardial lymphatic system function after MI.

  19. Transnodal Lymphangiography in the Diagnosis and Treatment of Genital Lymphedema

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, F. M., E-mail: gomez_fermun@gva.es; Martinez-Rodrigo, J.; Marti-Bonmati, L. [Hospital Universitario y Politecnico La Fe, Servicio de Radiologia (Spain); Santos, E. [University of Pittsburgh, Department of Radiology (United States); Forner, I. [Hospital Universitario y Politecnico La Fe, Servicio de Medicina Fisica y Rehabilitacion (Spain); Lloret, M.; Perez-Enguix, D.; Garcia-Marcos, R. [Hospital Universitario y Politecnico La Fe, Servicio de Radiologia (Spain)

    2012-12-15

    Purpose: To report the success of groin nodal lymphography in the diagnosis and treatment of genital lymphedema. Methods and Materials: We present one female (8 years old [patient no. 1]) and two male (69 and [patient no. 2] 31 years old [patient no. 3], respectively) patients with genital lymphedema in whom conservative treatment failed. The girl also had lymphorrhagia. Genital lymphedema was caused by radical cystectomy (patient no. 2), lymphatic hyperplasia (patient no. 1), and idiopathic lymphangitis (patient no. 3). All of them underwent ultrasound-guided bilateral groin lymph node puncture. Afterward, 4-8 ml Lipiodol Ultra-Fluide (Guerbet) were injected at a rate of 0.2 ml/s. Lipiodol progression was assessed by fluoroscopy. Computed tomography scan of the abdomen and pelvis was performed immediately after and again at 24 h after the procedure to confirm the leak. The follow-up period was 15, 13, and 9 months, respectively. Technical success was considered as bilateral pelvic and abdominal filling of lymphatic vessels. Therapeutic success was considered as improvement or disappearance of genital lymphedema and/or lymphorrhagia. Results: Lipiodol leak to the scrotum was observed in patients no. 2 and 3. Lymphaticopelvic fistula and genital lymphatic hyperplasia were seen in patient no. 1. Genital lymphedema diminished within 1 week and almost disappeared in two cases (patients no. 1 and 3) or significantly improved (patient no. 2). lymphorrhagia also resolved in patient no. 1. No recurrence or worsening was detected during follow-up. Conclusion: Therapeutic lymphangiography by lymph node injection seems to be effective to treat genital lymphedema. Lymph node puncture lymphangiography is feasible and less cumbersome than pedal lymphangiography.

  20. Transnodal Lymphangiography in the Diagnosis and Treatment of Genital Lymphedema

    International Nuclear Information System (INIS)

    Gómez, F. M.; Martínez-Rodrigo, J.; Martí-Bonmatí, L.; Santos, E.; Forner, I.; Lloret, M.; Pérez-Enguix, D.; García-Marcos, R.

    2012-01-01

    Purpose: To report the success of groin nodal lymphography in the diagnosis and treatment of genital lymphedema. Methods and Materials: We present one female (8 years old [patient no. 1]) and two male (69 and [patient no. 2] 31 years old [patient no. 3], respectively) patients with genital lymphedema in whom conservative treatment failed. The girl also had lymphorrhagia. Genital lymphedema was caused by radical cystectomy (patient no. 2), lymphatic hyperplasia (patient no. 1), and idiopathic lymphangitis (patient no. 3). All of them underwent ultrasound-guided bilateral groin lymph node puncture. Afterward, 4–8 ml Lipiodol Ultra-Fluide (Guerbet) were injected at a rate of 0.2 ml/s. Lipiodol progression was assessed by fluoroscopy. Computed tomography scan of the abdomen and pelvis was performed immediately after and again at 24 h after the procedure to confirm the leak. The follow-up period was 15, 13, and 9 months, respectively. Technical success was considered as bilateral pelvic and abdominal filling of lymphatic vessels. Therapeutic success was considered as improvement or disappearance of genital lymphedema and/or lymphorrhagia. Results: Lipiodol leak to the scrotum was observed in patients no. 2 and 3. Lymphaticopelvic fistula and genital lymphatic hyperplasia were seen in patient no. 1. Genital lymphedema diminished within 1 week and almost disappeared in two cases (patients no. 1 and 3) or significantly improved (patient no. 2). lymphorrhagia also resolved in patient no. 1. No recurrence or worsening was detected during follow-up. Conclusion: Therapeutic lymphangiography by lymph node injection seems to be effective to treat genital lymphedema. Lymph node puncture lymphangiography is feasible and less cumbersome than pedal lymphangiography.

  1. Comparative diagnostic study of staging in renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Masaharu; Mori, Masaki; Ito, Sachiko and others

    1986-04-01

    A comparative diagnostic study was carried out on 56 patients with pathologically proven renal cell carcinoma which had been staged by CT, US, angiography (AG) and lymphography (LG) between June, 1980, and May, 1985. The confirmation of the tumor extent was established by surgery and microscopic examination in all patients except three, in whom the extent of the tumor was determined at autopsy. CT and AG were performed in all cases. It was also studied how far various factors such as histologic architecture, cell type, grade, growth mode, tumor necrosis and bleeding were related with prognosis, and how to evaluate them in imaging modality. Concerning the T factor, there was no difference in diagnostic ability between images, and since prognosis of T4 was inferior to those of T2 and T3, diagnosis of T4 was seen to require particular attention. Drawing ability of N and V factors was poor in US. In LG, evaluation of regional lymph nodes was difficult, so this seems to be an unnecessary examination because CT can provide sufficient evaluation. By imaging modality, diagnosis of architecture and cell type was difficult. By AG, avascular to hypovascular tumors were of solid type, and there were many spindle or pleomorphic cell types and combination of tubular-granular types, while the papillary type was few. By macroscopic growth mode, the infiltrating type was poor in prognosis, and the presence or absence of halo was evaluated by CT and AG. Prognosis was favorable in cases having no necrosis in the tumor or accompanied by hemorrhage. For the purpose of diagnosis, CT was found to be sufficient, and it was concluded that AG may be used only for the purpose of renal arterial embolization as a preoperative treatment of low-stage cases subjected to nephrectomy. US is sufficient only if satisfying the role of screening. (J.P.N.).

  2. Discrimination of benign and malignant lymph nodes at 7.0T compared to 1.5T magnetic resonance imaging using ultrasmall particles of iron oxide: a feasibility preclinical study.

    Science.gov (United States)

    Kinner, Sonja; Maderwald, Stefan; Albert, Juliane; Parohl, Nina; Corot, Claire; Robert, Philippe; Baba, Hideo A; Barkhausen, Jörg

    2013-12-01

    To investigate the feasibility and performance of 7T magnetic resonance imaging compared to 1.5T imaging to discriminate benign (normal and inflammatory changed) from tumor-bearing lymph nodes in rabbits using ultrasmall particles of iron oxide (USPIO)-based contrast agents. Six New Zealand White rabbits were inoculated with either complete Freund's adjuvant cell suspension (n = 3) to induce reactively enlarged lymph nodes or with VX2 tumor cells to produce metastatic lymph nodes (n = 3). Image acquisition was performed before and 24 hours after bolus injection of an USPIO contrast agent at 1.5T and afterward at 7T using T1-weighted and T2*-weighted sequences. Sensitivities, specificities, and negative and positive predictive values for the detection of lymph node metastases were calculated for both field strengths with histopathology serving as reference standard. Sizes of lymph nodes with no, inflammatory, and malignant changes were compared using a Mann-Whitney U-test. All 24 lymph nodes were detected at 1.5T as well as at 7T. At 1.5T, sensitivity amounted to 0.67, while specificity reached a value of 1. At the higher field strength (7T), imaging was able to reach sensitivity and specificity values of 1. No statistical differences were detected concerning lymph node sizes. Magnetic resonance lymphography with USPIO contrast agents allows for differentiation of normal and reactively enlarged lymph nodes compared to metastatic nodes. First experiments at 7T show promising results compared to 1.5T, which have to be evaluated in further trials. Copyright © 2013. Published by Elsevier Inc.

  3. Observation of the lymph flow in the lower extremities of edematous patients with noninvasive methods

    International Nuclear Information System (INIS)

    Arai, Isao; Hirota, Akio; Watanabe, Sumio

    1983-01-01

    An RI-lymphography with a computer onlined gamma camera was used for observing the lymph flow of edematous patients without any invasive procedures and for estimating the active movement of lymph vessels. Subjects were composed of 8 normal volunteers (group 1), 41 non-edematous patients (group 2) and 26 edematous patients (group 3). Four mCi of Tc-99m-HSA in a volume of 0.1 ml was injected subcutaneously in the pretibial region of the lower extremity, and immediately after the injection scintigram was recorded on the thigh every 5 sec. for 30 min. Results: 1) Normal volunteers; Time-activity curves showed a gradual increase in RI activity in relation to time without remarkable spike-like fluctuations. The maximum count attained was less than 200 cps in all experiments. 2) Non-edematous patients; In 46 out of 57 experiments (80.8%), the similar time-activity curves were observed as those of the normal volunteers. On the other hand, time-activity curves in 11 out of 57 (19.2%) showed a much steeper stepwise-increase simultaneously with remarkable spike-waves. The maximum count was over 200 cps in these cases. 3) Edematous patients; In 12 out of 35 experiments (34.3%), the maximum count was over 200 cps. In these edematous diseases other than lymphedema and hyperthyroidism, time-activity curves showed a rapid stepwise increase with a lot of spikes, and the maximum count was over 500 cps in 6 experiments. In 23 out of 35 (65.7%), the maximum count was less than 200 cps. In these cases, edema was attributable to secondary lymphedema, hypothyroidism, aging and so on. 4) Relationship between edema and lymph flow: When subjects were divided into 3 groups (non-edema, mild and severe edema), the maximum count 200 cps was observed in 16.7% in non-edema group, 45.8% in mild and 9.1% in severe edema group

  4. Study on stability of labeled yttrium-90 with lipiodol by chemical extraction for liver cancer

    International Nuclear Information System (INIS)

    Mu, P.Y.; Jiang, X.L.; Chen, J.; Zhu, Y.J.

    2005-01-01

    human's blood (heparan lithium be used as anticoagulant). The results show that loss efficiencies of labeled yttrium-90 after adding newly-born cattle serum 1 hour, 1 day, 3 and 7 days are 3.38%, 3.12%, 4.2 % and 6.02%, and loss efficiencies of labeled yttrium-90 after adding human's blood 1 hour, 1 day, 3 and 7 days are 2.55%, 5.92%, 7.82% and 5.64%. 90 Y has been used for successful preclinical studies in liver cancers. It is the most possible radioisotope for labeling with lipiodol to treat hepatocellular carcinoma, particularly in cases of unresectable liver tumors, since 90 Y is available from several commercial sources in clinical quality, 90 Y has a half-life of 64 h and emits β-electrons with a maximum energy E max of 2.27 Mev, giving it a maximum range in tissue of 12 mm. Lipiodol is a sterile injectable radioopaque diagnostic agent used in lymphography and hysterosalpingography, because it is selectively retained in hepatocellular carcinoma. Lipiodol has been used as a vehicle to deliver localized doses of chemotherapeutic and radioactive agents to hepatocellular carcinoma following intra- arterial hepatic infusion. The stability tested with newly-born cattle serum and human's blood in this study attained great result, so we can carry on the further animal test and clinical trial.