  1. Left ventricle expands maximally preceding end-diastole. Radionuclide ventriculography study

    International Nuclear Information System (INIS)

    Horinouchi, Osamu

    2002-01-01

    It has been considered that left ventricle (LV) expands maximally at the end-diastole. However, is it exactly coincident with this point? This study was aimed to determine whether the maximal expansion of LV coincides with the peak of R wave on electrocardiogram. Thirty-three angina pectoris patients with normal LV motion were examined using radionuclide ventriculography. Data were obtained from every 30 ms backward frame from the peak of R wave. All patients showed the time of maximal expansion preceded the peak of R wave. The intervals from the peak of R wave and the onset of P wave to maximal expansion of LV was 105±29 ms and 88±25 ms, respectively. This period corresponds to the timing of maximal excurtion of mitral valve by atrial contraction, and the centripetal motion of LV without losing its volume before end-diastole may be interpreted on account of the movement of mitral valve toward closure. These findings suggest that LV expands maximally between P and R wave after atrial contraction, preceding the peak of R wave thought conventionally as the end-diastole. (author)

  2. Value of the regurgitant volume to end diastolic volume ratio to predict the regression of left ventricular dimensions after valve replacement in aortic insufficiency

    NARCIS (Netherlands)

    P.M. Fioretti (Paolo); C. Tirtaman; E. Bos (Egbert); P.W.J.C. Serruys (Patrick); J.R.T.C. Roelandt (Jos)

    1987-01-01

    textabstractThe aim of this study was to assess the value of regurgitant stroke volume (RSV) to end-diastolic volume (EDV) ratio to predict the regression of left ventricular (LV) dimensions after uncomplicated valve replacement in 34 patients with severe pure aortic insufficiency. The RSV/EDV ratio

  3. Differing responses in right and left ventricular filling, loading and volumes during positive end-expiratory pressure

    International Nuclear Information System (INIS)

    Schulman, D.S.; Biondi, J.W.; Matthay, R.A.; Zaret, B.L.; Soufer, R.

    1989-01-01

    Using a combined hemodynamic and radionuclide technique, 20 patients with varied ventricular function were evaluated during positive end-expiratory pressure (PEEP) application. Left ventricular (LV) and right ventricular (RV) ejection fractions and cardiac output were measured, and ventricular volumes were derived. Seven patients (group 1) who had an increase in LV end-diastolic volume with PEEP and 13 patients (group 2) who had the more typical response, a decrease in LV end-diastolic volume with PEEP, were identified. Compared with group 2, group 1 patients had a higher incidence of coronary artery disease (5 of 7 vs 1 of 13, p less than 0.005) and lower cardiac output (3.9 +/- 1.6 vs 9.1 +/- 3.2 liters/min, p less than 0.005), LV ejection fraction (27 +/- 13 vs 51 +/- 21%, p less than 0.05), RV ejection fraction (15 +/- 6 vs 32 +/- 8%, p less than 0.005) and peak filling rate (1.32 +/- 0.43 vs 3.51 +/- 1.70 end-diastolic volumes/s, p less than 0.05). LV and RV volumes increased and peak filling rate decreased with PEEP in group 1, whereas in group 2 LV volume decreased and RV volume and peak filling rate remained unchanged. Using stepwise regression analysis, the change in LV volume with PEEP was related directly to baseline systemic vascular resistance and inversely to baseline blood pressure. Similarly, the change in peak filling rate with PEEP was inversely related to the change in RV end-diastolic volume. Thus, the hemodynamic response to PEEP is heterogeneous and may be related to LV ischemia

  4. Pressure-volume Relationship in the Stress-echocardiography Laboratory: Does (Left Ventricular End-diastolic) Size Matter?

    Science.gov (United States)

    Bombardini, Tonino; Mulieri, Louis A; Salvadori, Stefano; Costantino, Marco Fabio; Scali, Maria Chiara; Marzilli, Mario; Picano, Eugenio

    2017-02-01

    The variation between rest and peak stress end-systolic pressure-volume relation is an afterload-independent index of left ventricular contractility. Whether and to what extent it depends on end-diastolic volume remains unclear. The aim of this study was to assess the dependence of the delta rest-stress end-systolic pressure-volume relation on end-diastolic volume in patients with negative stress echo and all ranges of resting left ventricular function. We analyzed interpretable data obtained in 891 patients (593 men, age 63 ± 12 years) with ejection fraction 47% ± 12%: 338 were normal or near-normal or hypertensive; 229 patients had coronary artery disease; and 324 patients had ischemic or nonischemic dilated cardiomyopathy. They were studied with exercise (n = 172), dipyridamole (n = 482) or dobutamine (n = 237) stress echocardiography. The end-systolic pressure-volume relation was evaluated at rest and peak stress from raw measurement of systolic arterial pressure by cuff sphygmomanometer and end-systolic volume by biplane Simpson rule 2-dimensional echocardiography. Absolute values of delta rest-stress end-systolic pressure-volume relation were higher for exercise and dobutamine than for dipyridamole. In the overall population, an inverse relationship between end-systolic pressure-volume relation and end-diastolic volume was present at rest (r 2 = 0.69, P stress (r 2 = 0.56, P stress end-systolic pressure-volume relation was considered (r 2 = 0.13). Left ventricular end-diastolic volume does not affect the rest-stress changes in end-systolic pressure-volume relation in either normal or abnormal left ventricles during physical or pharmacological stress. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  5. Left-sided cardiac chamber evaluation using single-phase mid-diastolic coronary computed tomography angiography: derivation of normal values and comparison with conventional end-diastolic and end-systolic phases

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Jonathan R. [Technion-Israel Institute of Technology, Haifa (Israel); Abadi, Sobhi [Rambam Health Care Campus, Medical Imaging Department, Haifa (Israel); Solomonica, Amir [Rambam Health Care Campus, Cardiology Department, Haifa (Israel); Mutlak, Diab; Aronson, Doron; Agmon, Yoram; Lessick, Jonathan [Rambam Health Care Campus, Cardiology Department, Haifa (Israel); Technion-Israel Institute of Technology, Haifa (Israel)

    2016-10-15

    With increasing use of prospective scanning techniques for cardiac computed tomography (CT), meaningful evaluation of chamber volumes is no longer possible due to lack of normal values. We aimed to define normal values for mid-diastolic (MD) chamber volumes and to determine their significance in comparison to maximum volumes. Normal ranges at MD for left ventricular (LV) volume and mass and left atrial (LA) volume were determined from 101 normal controls. Thereafter, 109 consecutive CT scans, as well as 21 post-myocardial infarction patients, were analysed to determine the relationship between MD and maximum volumes. MD volumes correlated closely with maximal volumes (r = 0.99) for both LV and LA, and could estimate maximum volumes accurately. LV mass, measured at ED or MD, were very similar (r = 0.99). Abnormal MD volumes had excellent sensitivity and specificity to detect chamber enlargement based on maximal volumes (LV 86 %, 100 %, respectively; LA 100 %, 92 %, respectively). A single MD phase can identify patients with cardiomegaly or LV hypertrophy with a high degree of accuracy and MD volumes can give an accurate estimate of maximum LV and LA volumes. circle Traditionally, helical cardiac CT provided clinically important information from chamber volume analysis. (orig.)

  6. Left ventricular diastolic filling in patients with systemic hypertension

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru; Kanao, Keisuke

    1985-01-01

    To study the prevalence and significance of left ventricular (LV) diastolic dysfunction in mild to moderate systemic hypertension (HT), cardiac blood pool imagings with Tc-99 m were obtained in 10 normal subjects and 27 patients with HT. The patients with HT did not show any evidence of coronary heart disease, renal insufficiency, cerebrovascular accident or diabetes mellitus. They were divided into 3 groups; (1) HT-1 (n=10): without evidence of echocardiographic (UCG) and electrocardiographic (ECG) left ventricular hypertrophy (LVH), (2) HT-2 (n=8): with evidence of ECG-LVH without UCG-LVH, (3) HT-3 (n=9): with evidence of UCG-LVH. UCG-LVH was defined when posterior or interventricular septal tall thickness exceeded 13 mm at end-diastole. From UCG findings LV mass was calculated and from UCG findings and auscultating brachial systolic pressure LV peak-systolic wall stress (WS) was obtained. Cardiac blood pool imagings were performed at modified LAO at rest and during exercise stress. Indices of LV systolic function (rest ejection fraction, mean ejection rate during the first third of ejection and exercise ejection fraction response) were essentially similar in normal subjects and all HT groups. In contrast, LV diastolic filling rate during the first third of diastole (1/3 FR mean) decreased significantly in any group of HT, and it was prominent in HT-3. In patients with HT, 1/3 FR mean did not correlate with blood pressure, LV peak-systolic WS, LV systolic functions and LV end-diastolic volume. But it correlated inversely with LV mass (r=-0.84). These results suggest that impairment of early diastolic LV filling can be detected before systolic cardiac impairment and LVH develop, and it is, at least in part, relate to the LV mass. (author)

  7. Correlation between left ventricular diastolic function before and after valve replacement surgery and myocardial ultrastructural changes in patients with left ventricular volume-overloaded valvular heart diseases

    International Nuclear Information System (INIS)

    Okada, Tomiro

    1993-01-01

    Left ventricular (LV) diastolic functions in 23 patients with aortic regurgitation (AR) and 22 patients with mitral regurgitation (MR) were evaluated by gated blood pool scintigraphy. LV myocardial biopsy was performed during open heart surgery, and LV myocardial ultrastructural changes were evaluated by electron microscope. Correlation between LV diastolic function and myocardial ultrastructural changes was examined. It was suggested that preoperative LV diastolic dysfunction occurred earlier than LV systolic dysfunction in patients with AR and MR. LV early diastolic dysfunction was especially significant in patients with AR. LV systolic function was significantly improved postoperatively compared with LV diastolic function in patients with AR and MR. It was suggested that LV interstitial fibrosis caused LV diastolic dysfunction in patients with AR and MR, and insufficiency of myocardial thickening as compensation in patients with MR. It was presumed that LV diastolic dysfunction was irreversible in patients with AR and MR in the distant postoperative period due to persistence of the preoperative myocardial ultrastructural change, e.g., interstitial fibrosis. These LV diastolic indices measured by gated pool scintigraphy were useful in predicting LV ultrastructural changes and postoperative LV dysfunction in patients with LV volume-overloaded valvular heart disease. (author)

  8. Diastolic compliance and exercise-induced left ventricular diastolic volume changes in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Choi, W.; Varma, V.; Wasserman, A.; Katz, R.; Reba, R.; Ross, A.

    1983-01-01

    This study consists of 46 consecutive patients who had supine resting and exercise multigated (MUGA) blood pool studies. All patients had angio-graphically important coronary stenosis in at least one major vessel. Thirty-five out of 46 patients with coronary artery disease increased left ventricular end diastolic volume with a supine exercise. The remaining eleven patients dit not dilate the left ventricle. Those patients, who were able to increase their end diastolic volume during exercise, had better compliance of the left ventricle manifested by lower end diastolic pressures, whereas, patients with poor left ventricular compliance were unable to volume expand during supine exercise

  9. Age-specific changes in left ventricular diastolic function: A velocity-encoded magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Ashrafpoor, Golmehr [Sorbonne Universites, UPMC Univ Paris 06, UMR 7371, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); INSERM, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); CNRS, UMR 7371, Laboratoire d' Imagerie Biomedicale, Paris (France); Universite Paris Descartes, Cardiovascular Imaging Department, European Hospital Georges Pompidou, Paris (France); Bollache, Emilie; Cesare, Alain de; Giron, Alain; Defrance, Carine; Kachenoura, Nadjia [Sorbonne Universites, UPMC Univ Paris 06, UMR 7371, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); INSERM, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); CNRS, UMR 7371, Laboratoire d' Imagerie Biomedicale, Paris (France); Redheuil, Alban [Sorbonne Universites, UPMC Univ Paris 06, UMR 7371, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); INSERM, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); CNRS, UMR 7371, Laboratoire d' Imagerie Biomedicale, Paris (France); Hopital Pitie-Salpetriere, Department of Cardiovascular Radiology, Institut de Cardiologie, Paris (France); ICAN, Imaging Core Lab, Paris (France); Azarine, Arshid [INSERM, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); Universite Paris Descartes, Cardiovascular Imaging Department, European Hospital Georges Pompidou, Paris (France); Perdrix, Ludivine; Ladouceur, Magalie [European Hospital Georges Pompidou, Cardiology Department, Paris (France); Diebold, Benoit [Sorbonne Universites, UPMC Univ Paris 06, UMR 7371, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); INSERM, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); CNRS, UMR 7371, Laboratoire d' Imagerie Biomedicale, Paris (France); European Hospital Georges Pompidou, Cardiology Department, Paris (France); Mousseaux, Elie [Sorbonne Universites, UPMC Univ Paris 06, UMR 7371, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); INSERM, UMR S 1146, Laboratoire d' Imagerie Biomedicale, Paris (France); CNRS, UMR 7371, Laboratoire d' Imagerie Biomedicale, Paris (France); Universite Paris Descartes, Cardiovascular Imaging Department, European Hospital Georges Pompidou, Paris (France); European Hospital Georges Pompidou, Cardiology Department, Paris (France)

    2015-04-01

    Our objectives were to assess the ability of phasecontrast MRI (PC-MRI) to detect sub-clinical age-related variations of left ventricular (LV) diastolic parameters and thus to provide age-related reference ranges currently available for echocardiography but not for MRI-PC, and to identify independent associates of such variations. We studied 100 healthy volunteers (age = 42 ± 15years, 50 females) who had MRI with simultaneous blood pressure measurements. LV mass and volumes were assessed. Semiautomated analysis of PC-MRI data provided: 1) early transmitral (Ef) and atrial (Af) peak filling flow-rates (ml/s) and filling volume (FV), 2) deceleration time (DT), isovolumic relaxation time (IVRT), and 3) early myocardial longitudinal (E') peak velocity. MRI-PC diastolic parameters were reproducible as reflected by low coefficients of variations (ranged between 0.31 to 6.26 %). Peak myocardial velocity E' (r = -0.63, p < 0.0001) and flow-rate parameters were strongly and independently associated to age (Ef/Af:r = -0.63, DT:r = 0.46, IVRT:r = 0.44, Ef/FV:r = -0.55, Af/FV:r = 0.56, p < 0.0001). Furthermore, LV relaxation parameters (E', DT, IVRT), were independently associated to LV remodelling (LV mass/end-diastolic volume) and myocardial wall thickness (p < 0.01). PC-MRI age-related reference ranges of diastolic parameters are provided. Such parameters might be useful for a fast, reproducible and reliable characterization of diastolic function in patients referred for clinical MRI exam. (orig.)

  10. Systolic and Diastolic Left Ventricular Mechanics during and after Resistance Exercise.

    Science.gov (United States)

    Stöhr, Eric J; Stembridge, Mike; Shave, Rob; Samuel, T Jake; Stone, Keeron; Esformes, Joseph I

    2017-10-01

    To improve the current understanding of the impact of resistance exercise on the heart, by examining the acute responses of left ventricular (LV) strain, twist, and untwisting rate ("LV mechanics"). LV echocardiographic images were recorded in systole and diastole before, during and immediately after (7-12 s) double-leg press exercise at two intensities (30% and 60% of maximum strength, one-repetition maximum). Speckle tracking analysis generated LV strain, twist, and untwisting rate data. Additionally, beat-by-beat blood pressure was recorded and systemic vascular resistance (SVR) and LV wall stress were calculated. Responses in both exercise trials were statistically similar (P > 0.05). During effort, stroke volume decreased, whereas SVR and LV wall stress increased (P mechanics (P 0.05). Immediately after exercise, systolic LV mechanics returned to baseline levels (P mechanics, but increases diastolic mechanics after exercise, suggesting that resistance exercise has a differential impact on systolic and diastolic heart muscle function. The findings may explain why acute resistance exercise has been associated with reduced stroke volume but chronic exercise training may result in increased LV volumes.

  11. Diastolic chamber properties of the left ventricle assessed by global fitting of pressure-volume data: improving the gold standard of diastolic function.

    Science.gov (United States)

    Bermejo, Javier; Yotti, Raquel; Pérez del Villar, Candelas; del Álamo, Juan C; Rodríguez-Pérez, Daniel; Martínez-Legazpi, Pablo; Benito, Yolanda; Antoranz, J Carlos; Desco, M Mar; González-Mansilla, Ana; Barrio, Alicia; Elízaga, Jaime; Fernández-Avilés, Francisco

    2013-08-15

    In cardiovascular research, relaxation and stiffness are calculated from pressure-volume (PV) curves by separately fitting the data during the isovolumic and end-diastolic phases (end-diastolic PV relationship), respectively. This method is limited because it assumes uncoupled active and passive properties during these phases, it penalizes statistical power, and it cannot account for elastic restoring forces. We aimed to improve this analysis by implementing a method based on global optimization of all PV diastolic data. In 1,000 Monte Carlo experiments, the optimization algorithm recovered entered parameters of diastolic properties below and above the equilibrium volume (intraclass correlation coefficients = 0.99). Inotropic modulation experiments in 26 pigs modified passive pressure generated by restoring forces due to changes in the operative and/or equilibrium volumes. Volume overload and coronary microembolization caused incomplete relaxation at end diastole (active pressure > 0.5 mmHg), rendering the end-diastolic PV relationship method ill-posed. In 28 patients undergoing PV cardiac catheterization, the new algorithm reduced the confidence intervals of stiffness parameters by one-fifth. The Jacobian matrix allowed visualizing the contribution of each property to instantaneous diastolic pressure on a per-patient basis. The algorithm allowed estimating stiffness from single-beat PV data (derivative of left ventricular pressure with respect to volume at end-diastolic volume intraclass correlation coefficient = 0.65, error = 0.07 ± 0.24 mmHg/ml). Thus, in clinical and preclinical research, global optimization algorithms provide the most complete, accurate, and reproducible assessment of global left ventricular diastolic chamber properties from PV data. Using global optimization, we were able to fully uncouple relaxation and passive PV curves for the first time in the intact heart.

  12. Correlation between left ventricular diastolic function before and after valve replacement surgery and myocardial ultrastructural changes in patients with left ventricular volume-overloaded valvular heart diseases; Evaluation with gated blood pool scintigraphy using [sup 99m]Tc

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Tomiro (Okayama Univ. (Japan). School of Medicine)

    1993-06-01

    Left ventricular (LV) diastolic functions in 23 patients with aortic regurgitation (AR) and 22 patients with mitral regurgitation (MR) were evaluated by gated blood pool scintigraphy. LV myocardial biopsy was performed during open heart surgery, and LV myocardial ultrastructural changes were evaluated by electron microscope. Correlation between LV diastolic function and myocardial ultrastructural changes was examined. It was suggested that preoperative LV diastolic dysfunction occurred earlier than LV systolic dysfunction in patients with AR and MR. LV early diastolic dysfunction was especially significant in patients with AR. LV systolic function was significantly improved postoperatively compared with LV diastolic function in patients with AR and MR. It was suggested that LV interstitial fibrosis caused LV diastolic dysfunction in patients with AR and MR, and insufficiency of myocardial thickening as compensation in patients with MR. It was presumed that LV diastolic dysfunction was irreversible in patients with AR and MR in the distant postoperative period due to persistence of the preoperative myocardial ultrastructural change, e.g., interstitial fibrosis. These LV diastolic indices measured by gated pool scintigraphy were useful in predicting LV ultrastructural changes and postoperative LV dysfunction in patients with LV volume-overloaded valvular heart disease. (author).

  13. NT-pro-BNP levels in patients with acute pulmonary embolism are correlated to right but not left ventricular volume and function.

    Science.gov (United States)

    Pasha, Sharif M; Klok, Frederikus A; van der Bijl, Noortje; de Roos, Albert; Kroft, Lucia J M; Huisman, Menno V

    2012-08-01

    N-terminal pro-Brain Natriuretic Peptide (NT-pro-BNP) is primarily secreted by left ventricular (LV) stretch and wall tension. Notably, NT-pro-BNP is a prognostic marker in acute pulmonary embolism (PE), which primarily stresses the right ventricle (RV). We sought to evaluate the relative contribution of the RV to NT-pro-BNP levels during PE. A post-hoc analysis of an observational prospective outcome study in 113 consecutive patients with computed tomography (CT)-proven PE and 226 patients in whom PE was clinically suspected but ruled out by CT. In all patients RV and LV function was established by assessing ECG-triggered-CT measured ventricular end-diastolic-volumes and ejection fraction (EF). NT-pro-BNP was assessed in all patients. The correlation between RV and LV end-diastolic-volumes and systolic function was evaluated by multiple linear regression corrected for known confounders. In the PE cohort increased RVEF (β-coefficient (95% confidence interval [CI]) -0.044 (± -0.011); p<0.001) and higher RV end-diastolic-volume (β-coefficient 0.005 (± 0.001); p<0.001) were significantly correlated to NT-pro-BNP, while no correlation was found with LVEF (β-coefficient 0.005 (± 0.010); p=0.587) and LV end-diastolic-volume (β-coefficient -0.003 (± 0.002); p=0.074). In control patients without PE we found a strong correlation between NT-pro-BNP levels and LVEF (β-coefficient -0.027 (± -0.006); p<0.001) although not LV end-diastolic-volume (β-coefficient 0.001 (± 0.001); p=0.418). RVEF (β-coefficient -0.002 (± -0.006); p=0.802) and RV end-diastolic-volume (β-coefficient <0.001 (± 0.001); p=0.730) were not correlated in patients without PE. In PE patients, lower RVEF and higher RV end-diastolic-volume were significantly correlated to NT-pro-BNP levels as compared to control patients without PE. These observations provide pathophysiological ground for the well-known prognostic value of NT-pro-BNP in acute PE.

  14. Left ventricular remodeling and fibrosis: Sex differences and relationship with diastolic function in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Chen, You-Zhou; Qiao, Shu-Bin; Hu, Feng-Huan; Yuan, Jian-Song; Yang, Wei-Xian; Cui, Jin-Gang; Zhang, Yan; Zhang, Chang-Lin

    2015-01-01

    Highlights: • There are significant differences in LV remodeling and fibrosis as divided by sex. • Women have worse diastolic dysfunction compared to men measured by CMR. • LV remodeling and fibrosis correlate with markers of diastolic dysfunction. - Abstract: Objectives: We investigated sex differences in left ventricular (LV) remodeling and fibrosis and their relationship with LV diastolic dysfunction by cardiovascular magnetic resonance (CMR). Methods: CMR imaging was performed simultaneously in 152 age-matched patients (76 men, 76 women; mean age: 49 ± 9 years) without LV systolic dysfunction. LV remodeling index (LVRI) was calculated as the ratio of LV mass and end-diastolic volume. Diastolic function indexes including peak filling rate (PFR) and time to PFR (tPFR) were evaluated. Extent of late gadolinium enhancement (LGE) was measured. Results: LVRI and extent of LGE were greater in women compared with men (1.48 ± 0.22 vs. 1.36 ± 0.28 g/ml; 13.15 ± 2.48 vs. 11.35 ± 2.34 g, respectively, both P < 0.001). Women had lower PFR and higher tPFR (both P < 0.001) than men. LVRI and the extent of LGE showed significant relationships with parameters of diastolic function in both sex. In a multivariate analysis, LVRI remained a strong independent predictor of PFR and TPFR in women (β = −0.272, P = 0.032; β = 0.348, P = 0.016, respectively), and in men (β = −0.374, P < 0.001; β = 0.660, P < 0.001, respectively). Furthermore, the extent of LGE also remained an independent predictor of PFR in women (β = −0.283, P = 0.033) and men (β = −0.492, P < 0.001). Conclusions: There are prominent sex differences in LV remodeling and myocardial fibrosis. We suggest that the effects of LV remodeling and fibrosis may lead to diastolic dysfunction with greater susceptibility to worse clinical outcome in women

  15. Left ventricular remodeling and fibrosis: Sex differences and relationship with diastolic function in hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, You-Zhou [Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Qiao, Shu-Bin, E-mail: qsbfw@sina.com [Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Hu, Feng-Huan; Yuan, Jian-Song; Yang, Wei-Xian; Cui, Jin-Gang [Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Zhang, Yan [Department of Radiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Zhang, Chang-Lin [Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China)

    2015-08-15

    Highlights: • There are significant differences in LV remodeling and fibrosis as divided by sex. • Women have worse diastolic dysfunction compared to men measured by CMR. • LV remodeling and fibrosis correlate with markers of diastolic dysfunction. - Abstract: Objectives: We investigated sex differences in left ventricular (LV) remodeling and fibrosis and their relationship with LV diastolic dysfunction by cardiovascular magnetic resonance (CMR). Methods: CMR imaging was performed simultaneously in 152 age-matched patients (76 men, 76 women; mean age: 49 ± 9 years) without LV systolic dysfunction. LV remodeling index (LVRI) was calculated as the ratio of LV mass and end-diastolic volume. Diastolic function indexes including peak filling rate (PFR) and time to PFR (tPFR) were evaluated. Extent of late gadolinium enhancement (LGE) was measured. Results: LVRI and extent of LGE were greater in women compared with men (1.48 ± 0.22 vs. 1.36 ± 0.28 g/ml; 13.15 ± 2.48 vs. 11.35 ± 2.34 g, respectively, both P < 0.001). Women had lower PFR and higher tPFR (both P < 0.001) than men. LVRI and the extent of LGE showed significant relationships with parameters of diastolic function in both sex. In a multivariate analysis, LVRI remained a strong independent predictor of PFR and TPFR in women (β = −0.272, P = 0.032; β = 0.348, P = 0.016, respectively), and in men (β = −0.374, P < 0.001; β = 0.660, P < 0.001, respectively). Furthermore, the extent of LGE also remained an independent predictor of PFR in women (β = −0.283, P = 0.033) and men (β = −0.492, P < 0.001). Conclusions: There are prominent sex differences in LV remodeling and myocardial fibrosis. We suggest that the effects of LV remodeling and fibrosis may lead to diastolic dysfunction with greater susceptibility to worse clinical outcome in women.

  16. Global end-diastolic volume an emerging preload marker vis-a-vis other markers - Have we reached our goal?

    Directory of Open Access Journals (Sweden)

    P M Kapoor

    2016-01-01

    Full Text Available A reliable estimation of cardiac preload is helpful in the management of severe circulatory dysfunction. The estimation of cardiac preload has evolved from nuclear angiography, pulmonary artery catheterization to echocardiography, and transpulmonary thermodilution (TPTD. Global end-diastolic volume (GEDV is the combined end-diastolic volumes of all the four cardiac chambers. GEDV has been demonstrated to be a reliable preload marker in comparison with traditionally used pulmonary artery catheter-derived pressure preload parameters. Recently, a new TPTD system called EV1000™ has been developed and introduced into the expanding field of advanced hemodynamic monitoring. GEDV has emerged as a better preload marker than its previous conventional counterparts. The advantage of it being measured by minimum invasive methods such as PiCCO™ and newly developed EV1000™ system makes it a promising bedside advanced hemodynamic parameter.

  17. Mast cell stabilization decreases cardiomyocyte and LV function in dogs with isolated mitral regurgitation.

    Science.gov (United States)

    Pat, Betty; Killingsworth, Cheryl; Chen, Yuanwen; Gladden, James D; Walcott, Greg; Powell, Pamela C; Denney, Thomas; Gupta, Himanshu; Desai, Ravi; Tillson, Michael; Dillon, A Ray; Dell'italia, Louis J

    2010-09-01

    Mast cells are increased in isolated mitral regurgitation (MR) in the dog and may mediate extracellular matrix loss and left ventricular (LV) dilatation. We tested the hypothesis that mast cell stabilization would attenuate LV remodeling and improve function in the MR dog. MR was induced in adult dogs randomized to no treatment (MR, n = 5) or to the mast cell stabilizer, ketotifen (MR + MCS, n = 4) for 4 months. LV hemodynamics were obtained at baseline and after 4 months of MR and magnetic resonance imaging (MRI) was performed at sacrifice. MRI-derived, serial, short-axis LV end-diastolic (ED) and end-systolic (ES) volumes, LVED volume/mass ratio, and LV 3-dimensional radius/wall thickness were increased in MR and MR + MCS dogs compared with normal dogs (n = 6) (P < .05). Interstitial collagen was decreased by 30% in both MR and MR + MCS versus normal dogs (P < .05). LV contractility by LV maximum time-varying elastance was significantly depressed in MR and MR + MCS dogs. Furthermore, cardiomyocyte fractional shortening was decreased in MR versus normal dogs and further depressed in MR + MCS dogs (P < .05). In vitro administration of ketotifen to normal cardiomyocytes also significantly decreased fractional shortening and calcium transients. Chronic mast cell stabilization did not attenuate eccentric LV remodeling or collagen loss in MR. However, MCS therapy had a detrimental effect on LV function because of a direct negative inotropic effect on cardiomyocyte function. Published by Elsevier Inc.

  18. Low tidal volume ventilation ameliorates left ventricular dysfunction in mechanically ventilated rats following LPS-induced lung injury.

    Science.gov (United States)

    Cherpanath, Thomas G V; Smeding, Lonneke; Hirsch, Alexander; Lagrand, Wim K; Schultz, Marcus J; Groeneveld, A B Johan

    2015-10-07

    High tidal volume ventilation has shown to cause ventilator-induced lung injury (VILI), possibly contributing to concomitant extrapulmonary organ dysfunction. The present study examined whether left ventricular (LV) function is dependent on tidal volume size and whether this effect is augmented during lipopolysaccharide(LPS)-induced lung injury. Twenty male Wistar rats were sedated, paralyzed and then randomized in four groups receiving mechanical ventilation with tidal volumes of 6 ml/kg or 19 ml/kg with or without intrapulmonary administration of LPS. A conductance catheter was placed in the left ventricle to generate pressure-volume loops, which were also obtained within a few seconds of vena cava occlusion to obtain relatively load-independent LV systolic and diastolic function parameters. The end-systolic elastance / effective arterial elastance (Ees/Ea) ratio was used as the primary parameter of LV systolic function with the end-diastolic elastance (Eed) as primary LV diastolic function. Ees/Ea decreased over time in rats receiving LPS (p = 0.045) and high tidal volume ventilation (p = 0.007), with a lower Ees/Ea in the rats with high tidal volume ventilation plus LPS compared to the other groups (p tidal volume ventilation without LPS (p = 0.223). A significant interaction (p tidal ventilation and LPS for Ees/Ea and Eed, and all rats receiving high tidal volume ventilation plus LPS died before the end of the experiment. Low tidal volume ventilation ameliorated LV systolic and diastolic dysfunction while preventing death following LPS-induced lung injury in mechanically ventilated rats. Our data advocates the use of low tidal volumes, not only to avoid VILI, but to avert ventilator-induced myocardial dysfunction as well.

  19. Automatic detection of end-diastole and end-systole from echocardiography images using manifold learning

    International Nuclear Information System (INIS)

    Gifani, Parisa; Behnam, Hamid; Shalbaf, Ahmad; Sani, Zahra Alizadeh

    2010-01-01

    The automatic detection of end-diastole and end-systole frames of echocardiography images is the first step for calculation of the ejection fraction, stroke volume and some other features related to heart motion abnormalities. In this paper, the manifold learning algorithm is applied on 2D echocardiography images to find out the relationship between the frames of one cycle of heart motion. By this approach the nonlinear embedded information in sequential images is represented in a two-dimensional manifold by the LLE algorithm and each image is depicted by a point on reconstructed manifold. There are three dense regions on the manifold which correspond to the three phases of cardiac cycle ('isovolumetric contraction', 'isovolumetric relaxation', 'reduced filling'), wherein there is no prominent change in ventricular volume. By the fact that the end-systolic and end-diastolic frames are in isovolumic phases of the cardiac cycle, the dense regions can be used to find these frames. By calculating the distance between consecutive points in the manifold, the isovolumic frames are mapped on the three minimums of the distance diagrams which were used to select the corresponding images. The minimum correlation between these images leads to detection of end-systole and end-diastole frames. The results on six healthy volunteers have been validated by an experienced echo cardiologist and depict the usefulness of the presented method

  20. Left ventricular diastolic dyssynchrony assessed with phase analysis of gated myocardial perfusion SPECT: a comparison with tissue Doppler imaging

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Veltman, Caroline E.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Mooyaart, Eline A.Q.; Wall, Ernst E. van der; Schalij, Martin J.; Bax, Jeroen J.; Delgado, Victoria; Younis, Imad Al; Hiel, Bernies van der; Dibbets-Schneider, Petra

    2011-01-01

    The aim of the current study was to evaluate the feasibility of phase analysis on gated myocardial perfusion SPECT (GMPS) for the assessment of left ventricular (LV) diastolic dyssynchrony in a head-to-head comparison with tissue Doppler imaging (TDI). The population consisted of patients with end-stage heart failure of New York Heart Association functional class III or IV with a reduced LV ejection fraction of ≤35%. LV diastolic dyssynchrony was calculated using TDI as the maximal time delay between early peak diastolic velocities of two opposing left ventricle walls (diastolic mechanical delay). Significant LV diastolic dyssynchrony was defined as a diastolic mechanical delay of >55 ms on TDI. Furthermore, phase analysis on GMPS was performed to evaluate LV diastolic dyssynchrony; diastolic phase standard deviation (SD) and histogram bandwidth (HBW) were used as markers of LV diastolic dyssynchrony. A total of 150 patients (114 men, mean age 66.0 ± 10.4 years) with end-stage heart failure were enrolled. Both diastolic phase SD (r = 0.81, p 55 ms) showed significantly larger diastolic phase SD (68.1 ± 13.4 vs. 40.7 ± 14.0 , p < 0.01) and diastolic HBW (230.6 ± 54.3 vs. 129.0 ± 55.6 , p < 0.01) as compared to patients without LV diastolic dyssynchrony on TDI (≤55 ms). Finally, phase analysis on GMPS showed a good intra- and interobserver reproducibility for the determination of diastolic phase SD (ICC 0.97 and 0.88) and diastolic HBW (ICC 0.98 and 0.93). Phase analysis on GMPS showed good correlations with TDI for the assessment of LV diastolic dyssynchrony. (orig.)

  1. Percutaneous closure of patent ductus arteriosus in children: Immediate and short-term changes in left ventricular systolic and diastolic function

    Directory of Open Access Journals (Sweden)

    Saurabh Kumar Gupta

    2011-01-01

    Full Text Available Objective: To evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA on left ventricular (LV systolic and diastolic function in children. Background: Limited studies are available on alteration in LV hemodynamics, especially diastolic function, after PDA closure. Methods: Thirty-two consecutive children with isolated PDA treated by trans-catheter closure were studied. The LV systolic and diastolic function were assessed by two-dimensional (2D echocardiography and tissue Doppler imaging 1 day before the PDA closure, on day 1, and on follow-up. Results: At baseline, none of the patients had LV systolic dysfunction. On day 1 post-PDA closure, 8 (25% children developed LV systolic dysfunction. The baseline LV ejection fraction (LVEF, LV end-systolic dimension (LVESD, and PDA diastolic gradient predicted the post-closure LVEF. Patients who developed post-closure LV systolic dysfunction had poorer LV diastolic function than those who did not. LV diastolic properties improved after PDA closure; however, the improvement in LV diastolic properties lagged behind the improvement in the LV systolic function. All children were asymptomatic and had normal LVEF on follow up of >3 months. Conclusions: Percutaneous closure of PDA is associated with the reversible LV systolic dysfunction. Improvement in the LV diastolic function lags behind that in the LV systolic function.

  2. Percutaneous closure of patent ductus arteriosus in children: Immediate and short-term changes in left ventricular systolic and diastolic function.

    Science.gov (United States)

    Gupta, Saurabh Kumar; Krishnamoorthy, Km; Tharakan, Jaganmohan A; Sivasankaran, S; Sanjay, G; Bijulal, S; Anees, T

    2011-07-01

    To evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) systolic and diastolic function in children. Limited studies are available on alteration in LV hemodynamics, especially diastolic function, after PDA closure. Thirty-two consecutive children with isolated PDA treated by trans-catheter closure were studied. The LV systolic and diastolic function were assessed by two-dimensional (2D) echocardiography and tissue Doppler imaging 1 day before the PDA closure, on day 1, and on follow-up. At baseline, none of the patients had LV systolic dysfunction. On day 1 post-PDA closure, 8 (25%) children developed LV systolic dysfunction. The baseline LV ejection fraction (LVEF), LV end-systolic dimension (LVESD), and PDA diastolic gradient predicted the post-closure LVEF. Patients who developed post-closure LV systolic dysfunction had poorer LV diastolic function than those who did not. LV diastolic properties improved after PDA closure; however, the improvement in LV diastolic properties lagged behind the improvement in the LV systolic function. All children were asymptomatic and had normal LVEF on follow up of >3 months. Percutaneous closure of PDA is associated with the reversible LV systolic dysfunction. Improvement in the LV diastolic function lags behind that in the LV systolic function.

  3. Diastolic dysfunction and diastolic heart failure: diagnostic, prognostic and therapeutic aspects

    Directory of Open Access Journals (Sweden)

    Galderisi Maurizio

    2005-04-01

    Full Text Available Abstract Left ventricular (LV diastolic dysfunction (DD and diastolic heart failure (HF, that is symptomatic DD, are due to alterations of myocardial diastolic properties. These alterations involve relaxation and/or filling and/or distensibility. Arterial hypertension associated to LV concentric remodelling is the main determinant of DD but several other cardiac diseases, including myocardial ischemia, and extra-cardiac pathologies involving the heart are other possible causes. In the majority of the studies, isolated diastolic HF has been made equal to HF with preserved systolic function (= normal ejection fraction but the true definition of this condition needs a quantitative estimation of LV diastolic properties. According to the position of the European Society of Cardiology and subsequent research refinements the use of Doppler echocardiography (transmitral inflow and pulmonary venous flow and the new ultrasound tools has to be encouraged for diagnosis of DD. In relation to uncertain definitions, both prevalence and prognosis of diastolic heart failure are very variable. Despite an apparent lower death rate in comparison with LV systolic HF, long-term follow-up (more than 5 years show similar mortality between the two kinds of HF. Recent studies performed by Doppler diastolic indexes have identified the prognostic power of both transmitral E/A ratio 1.5 (restrictive patterns. The therapy of LV DD and HF is not well established but ACE-inhibitors, angiotensin inhibitors, aldosterone antagonists and β-blockers show potential beneficial effect on diastolic properties. Several trials, completed or ongoing, have been planned to treat DD and diastolic HF.

  4. Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET.

    Science.gov (United States)

    Harms, Hendrik Johannes; Stubkjær Hansson, Nils Henrik; Tolbod, Lars Poulsen; Kim, Won Yong; Jakobsen, Steen; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiaer, Jørgen; Sörensen, Jens

    2016-09-01

    Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  5. Assessment of global and regional LV function obtained by quantitative gated SPECT using {sup 99m}Tc-tetrofosmin. Comparison with left ventricular cineangiography and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Kazunobu; Nakajima, Toru; Aoki, Naoto; Abe, Sumihisa; Handa, Shunnosuke; Suzuki, Yutaka [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine

    1998-11-01

    The quantitative gated SPECT (QGS) software that has automatic edge detection algorithm of the left ventricle, is able to calculate LV volumes and visualize LV wall motion with perfusion throughout the cardiac cycle. We evaluated the reliability of global and regional LV function derived from QGS using {sup 99m}Tc-tetrofosmin by comparing with left ventricular cineangiography (LVG) and echocardiography (ECHO). In 22 cardiac patients, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were calculated. Using cinematic display, regional LV wall motion were scored on a 3-point scale (1=normal, 2=hypokinesis, 3=akinesis; WMS). EDV, ESV and LVEF correlated well with those by LVG (p<0.001 for each). Correlation between WMS derived from QGS and ECHO was high (r=0.85, p<0.001). There was an inverse correlation between WMS and LVEF (r=0.77, p<0.001). In conclusion, QGS is useful to evaluate global LV function. Regional wall motion evaluated by QGS is good enough for clinical application. (author)

  6. LV function monitoring to discard functional abnormalities in athletes with altered ventricular re-polarization

    International Nuclear Information System (INIS)

    Flotats, A.; Camacho, V.; Mena, E.; Tembl, A.; Estorch, M.; Carrio, I.; Serra-Grima, R.; Borras, X.; Cinca, J.

    2002-01-01

    Aim: Marked ventricular re-polarization abnormalities (MRA) in athletes may suggest the presence of associated heart disease. Assessment of LV function during exercise may contribute to rule out heart disease and help to decide continuation of physical training. The aim of the study was to assess whether athletes with MRA show a particular response of LV function to exhausting exercise. Material and Methods: Thirty-nine male athletes underwent monitoring of LV function with a miniaturised radionuclide detector (VEST, Capintec, Inc.) during bicycle exhausting exercise. There were 22 athletes with MRA in the ECG at rest (negative T waves equal or more than 2mm in up to 3 ECG leads) and 17 with normal ECG. All were symptom free. Age and physical fitness were comparable in both groups. Clinical examination, ECG, exercise test and echocardiography were performed in all athletes. Results: In all cases LV wall thickness was that expected for highly conditioned sportsmen. Both groups of athletes attained a similar energy expenditure. During exercise, athletes with MRA showed a tendency to normalise re-polarization. There were no differences in heart rate, LV end-systolic volume, LVEF, cardiac output , and peak ejection and filling rates at rest, 50%, 75%, 85% and 100% of peak HR, nor at 2, 5 and 10 min of recovery between both groups of athletes. At rest stroke volume was lower in athletes with MRA (60% vs. 64%, p=0.044). There were also no differences in LV end-diastolic volume (EDV), except at peak HR, when EDV increased in athletes with normal ECG while it decreased in athletes with MRA (p=0.047). Conclusions: The presence of marked ventricular re-polarization abnormalities in athletes does not substantially affect exercise performance nor LV function and should not preclude physical training. The VEST is a useful means to assess LV function during exhausting upright bicycle exercise

  7. Arterial stiffness and wave reflection: sex differences and relationship with left ventricular diastolic function.

    Science.gov (United States)

    Russo, Cesare; Jin, Zhezhen; Palmieri, Vittorio; Homma, Shunichi; Rundek, Tatjana; Elkind, Mitchell S V; Sacco, Ralph L; Di Tullio, Marco R

    2012-08-01

    Increased arterial stiffness and wave reflection have been reported in heart failure with normal ejection fraction (HFNEF) and in asymptomatic left ventricular (LV) diastolic dysfunction, a precursor of HFNEF. It is unclear whether women, who have higher frequency of HFNEF, are more vulnerable than men to the deleterious effects of arterial stiffness on LV diastolic function. We investigated, in a large community-based cohort, whether sex differences exist in the relationship among arterial stiffness, wave reflection, and LV diastolic function. Arterial stiffness and wave reflection were assessed in 983 participants from the Cardiovascular Abnormalities and Brain Lesions study using applanation tonometry. The central pulse pressure/stroke volume index, total arterial compliance, pulse pressure amplification, and augmentation index were used as parameters of arterial stiffness and wave reflection. LV diastolic function was evaluated by 2-dimensional echocardiography and tissue-Doppler imaging. Arterial stiffness and wave reflection were greater in women compared with men, independent of body size and heart rate (all Pfunction in both sexes. Further adjustment for cardiovascular risk factors attenuated these relationships; however, a higher central pulse pressure/stroke volume index predicted LV diastolic dysfunction in women (odds ratio, 1.54; 95% confidence intervals, 1.03 to 2.30) and men (odds ratio, 2.09; 95% confidence interval, 1.30 to 3.39), independent of other risk factors. In conclusion, in our community-based cohort study, higher arterial stiffness was associated with worse LV diastolic function in men and women. Women's higher arterial stiffness, independent of body size, may contribute to their greater susceptibility to develop HFNEF.

  8. Hypertensive heart disease versus hypertrophic cardiomyopathy: multi-parametric cardiovascular magnetic resonance discriminators when end-diastolic wall thickness ≥ 15 mm

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Jonathan C.L. [University Hospitals Bristol NHS Foundation Trust, NIHR Bristol Cardiovascular Biomedical Research Unit, Cardiac Magnetic Resonance Department, Bristol Heart Institute (United Kingdom); University of Bristol, School of Physiology, Pharmacology and Neuroscience, Faculty of Biomedical Sciences (United Kingdom); Rohan, Stephen [University of Bristol, Medical School, Faculty of Medicine and Dentistry (United Kingdom); Ghosh Dastidar, Amardeep; Harries, Iwan; Lawton, Christopher B. [University Hospitals Bristol NHS Foundation Trust, NIHR Bristol Cardiovascular Biomedical Research Unit, Cardiac Magnetic Resonance Department, Bristol Heart Institute (United Kingdom); Ratcliffe, Laura E.; Burchell, Amy E.; Nightingale, Angus K. [University Hospitals Bristol NHS Foundation Trust, CardioNomics Research Group, Clinical Research and Imaging Centre, Bristol Heart Institute (United Kingdom); Hart, Emma C.; Paton, Julian F.R. [University of Bristol, School of Physiology, Pharmacology and Neuroscience, Faculty of Biomedical Sciences (United Kingdom); University Hospitals Bristol NHS Foundation Trust, CardioNomics Research Group, Clinical Research and Imaging Centre, Bristol Heart Institute (United Kingdom); Hamilton, Mark C.K. [University Hospitals Bristol NHS Foundation Trust, Department of Radiology, Bristol Royal Infirmary (United Kingdom); Manghat, Nathan E. [University Hospitals Bristol NHS Foundation Trust, NIHR Bristol Cardiovascular Biomedical Research Unit, Cardiac Magnetic Resonance Department, Bristol Heart Institute (United Kingdom); University Hospitals Bristol NHS Foundation Trust, Department of Radiology, Bristol Royal Infirmary (United Kingdom)

    2017-03-15

    European guidelines state left ventricular (LV) end-diastolic wall thickness (EDWT) ≥15 mm suggests hypertrophic cardiomyopathy (HCM), but distinguishing from hypertensive heart disease (HHD) is challenging. We identify cardiovascular magnetic resonance (CMR) predictors of HHD over HCM when EDWT ≥15 mm. 2481 consecutive clinical CMRs between 2014 and 2015 were reviewed. 464 segments from 29 HCM subjects with EDWT ≥15 mm but without other cardiac abnormality, hypertension or renal impairment were analyzed. 432 segments from 27 HHD subjects with EDWT ≥15 mm but without concomitant cardiac pathology were analyzed. Magnitude and location of maximal EDWT, presence of late gadolinium enhancement (LGE), LV asymmetry (>1.5-fold opposing segment) and systolic anterior motion of the mitral valve (SAM) were measured. Multivariate logistic regression was performed. Significance was defined as p<0.05. HHD and HCM cohorts were age-/gender-matched. HHD had significantly increased indexed LV mass (110±27 g/m{sup 2} vs. 91±31 g/m{sup 2}, p=0.016) but no difference in site or magnitude of maximal EDWT. Mid-wall LGE was significantly more prevalent in HCM. Elevated indexed LVM, mid-wall LGE and absence of SAM were significant multivariate predictors of HHD, but LV asymmetry was not. Increased indexed LV mass, absence of mid-wall LGE and absence of SAM are better CMR discriminators of HHD from HCM than EDWT ≥15 mm. circle Hypertrophic cardiomyopathy (HCM) is often diagnosed with end-diastolic wall thickness ≥15 mm. (orig.)

  9. Hypertensive heart disease versus hypertrophic cardiomyopathy: multi-parametric cardiovascular magnetic resonance discriminators when end-diastolic wall thickness ≥ 15 mm

    International Nuclear Information System (INIS)

    Rodrigues, Jonathan C.L.; Rohan, Stephen; Ghosh Dastidar, Amardeep; Harries, Iwan; Lawton, Christopher B.; Ratcliffe, Laura E.; Burchell, Amy E.; Nightingale, Angus K.; Hart, Emma C.; Paton, Julian F.R.; Hamilton, Mark C.K.; Manghat, Nathan E.

    2017-01-01

    European guidelines state left ventricular (LV) end-diastolic wall thickness (EDWT) ≥15 mm suggests hypertrophic cardiomyopathy (HCM), but distinguishing from hypertensive heart disease (HHD) is challenging. We identify cardiovascular magnetic resonance (CMR) predictors of HHD over HCM when EDWT ≥15 mm. 2481 consecutive clinical CMRs between 2014 and 2015 were reviewed. 464 segments from 29 HCM subjects with EDWT ≥15 mm but without other cardiac abnormality, hypertension or renal impairment were analyzed. 432 segments from 27 HHD subjects with EDWT ≥15 mm but without concomitant cardiac pathology were analyzed. Magnitude and location of maximal EDWT, presence of late gadolinium enhancement (LGE), LV asymmetry (>1.5-fold opposing segment) and systolic anterior motion of the mitral valve (SAM) were measured. Multivariate logistic regression was performed. Significance was defined as p<0.05. HHD and HCM cohorts were age-/gender-matched. HHD had significantly increased indexed LV mass (110±27 g/m"2 vs. 91±31 g/m"2, p=0.016) but no difference in site or magnitude of maximal EDWT. Mid-wall LGE was significantly more prevalent in HCM. Elevated indexed LVM, mid-wall LGE and absence of SAM were significant multivariate predictors of HHD, but LV asymmetry was not. Increased indexed LV mass, absence of mid-wall LGE and absence of SAM are better CMR discriminators of HHD from HCM than EDWT ≥15 mm. circle Hypertrophic cardiomyopathy (HCM) is often diagnosed with end-diastolic wall thickness ≥15 mm. (orig.)

  10. Geographic origin as a determinant of left ventricular mass and diastolic function - the Cardiovascular Risk in Young Finns Study.

    Science.gov (United States)

    Vähämurto, L; Juonala, M; Ruohonen, S; Hutri-Kähönen, N; Kähönen, M; Laitinen, T; Tossavainen, P; Jokinen, E; Viikari, J; Raitakari, O T; Pahkala, K

    2018-03-01

    Eastern Finns have higher risk of coronary heart disease (CHD) and carotid intima-media thickness than western Finns although current differences in CHD risk factors are minimal. Left ventricular (LV) mass and diastolic function predict future cardiovascular events but their east-west differences are unknown. We examined the association of eastern/western baseline origin with LV mass and diastolic function. The study population included 2045 subjects of the Cardiovascular Risk in Young Finns Study with data from the baseline survey (1980) and the latest follow-up (2011) when echocardiography was performed at the age of 34-49 years. Subjects with eastern baseline origin had in 2011 higher LV mass (139±1.0 vs. 135±1.0 g, p=0.006) and E/e'-ratio indicating weaker LV diastolic function (4.86±0.03 vs. 4.74±0.03, p=0.02) than western subjects. Results were independent of age, sex, area of examination and CHD risk factors such as blood pressure and BMI (LV mass indexed with height: porigin (135±0.9 vs. 131±0.9 ml, p=0.0011) but left atrial end-systolic volume, also indicating LV diastolic function, was not different between eastern and western subjects (43.4±0.5 vs. 44.0±0.5 ml, p=0.45). Most of the subjects were well within the normal limits of these echocardiographic measurements. In our healthy middle-aged population, geographic origin in eastern Finland associated with higher LV mass compared to western Finland. Higher E/e'-ratio suggests that subjects with eastern baseline origin might have higher prevalence of diastolic dysfunction in the future than western subjects.

  11. Peak negative myocardial velocity gradient in early diastole as a noninvasive indicator of left ventricular diastolic function: comparison with transmitral flow velocity indices.

    Science.gov (United States)

    Shimizu, Y; Uematsu, M; Shimizu, H; Nakamura, K; Yamagishi, M; Miyatake, K

    1998-11-01

    We sought to assess the clinical significance of peak negative myocardial velocity gradient (MVG) in early diastole as a noninvasive indicator of left ventricular (LV) diastolic function. Peak systolic MVG has been shown useful for the quantitative assessment of regional wall motion abnormalities, but limited data exist regarding the diastolic MVG as an indicator of LV diastolic function. Peak negative MVG was obtained from M-mode tissue Doppler imaging (TDI) in 43 subjects with or without impairment of systolic and diastolic performance: 12 normal subjects, 12 patients with hypertensive heart disease (HHD) with normal systolic performance and 19 patients with dilated cardiomyopathy (DCM), and was compared with standard Doppler transmitral flow velocity indices. In a subgroup of 30 patients, effects of preload increase on these indices were assessed by performing passive leg lifting. In an additional 11 patients with congestive heart failure at the initial examination, the measurements were repeated after 26+/-16 days of volume-reducing therapy. Peak negative MVG was significantly depressed both in HHD (-3.9+/-1.3/s, p indices failed to distinguish DCM from normal due to the pseudonormalization. Transmitral flow velocity indices were significantly altered (peak early/late diastolic filling velocity [E/A]=1.1+/-0.5 to 1.5+/-0.7, p indicator of LV diastolic function that is less affected by preload alterations than the transmitral flow velocity indices, and thereby could be used for the follow-up of patients with nonischemic LV dysfunction presenting congestive heart failure.

  12. Abnormal glucose metabolism in acute myocardial infarction: influence on left ventricular function and prognosis

    DEFF Research Database (Denmark)

    Høfsten, Dan E; Løgstrup, Brian B; Møller, Jacob E

    2009-01-01

    tolerance test before discharge. LV function was assessed using echocardiographic measurements (LV end-diastolic volume, LV end-systolic volume, LV ejection fraction, restrictive diastolic filling pattern, early transmitral flow velocity to early diastolic mitral annular velocity ratio [E/e'], and left...... atrial volume index) and by measuring plasma N-terminal pro-B-type natriuretic peptide levels. RESULTS: After adjustment for age and gender, a linear relationship between the degree of abnormal glucose metabolism was observed for each marker of LV dysfunction (p(trend)

  13. Reference absolute and indexed values for left and right ventricular volume, function and mass from cardiac computed tomography

    International Nuclear Information System (INIS)

    Stojanovska, Jadranka; Prasitdumrong, Hutsaya; Patel, Smita; Sundaram, Baskaran; Gross, Barry H.; Yilmaz, Zeynep N.; Kazerooni, Ella A.

    2014-01-01

    Left ventricular (LV) and right ventricular (RV) volumetric and functional parameters are important biomarkers for morbidity and mortality in patients with heart failure. To retrospectively determine reference mean values of LV and RV volume, function and mass normalised by age, gender and body surface area (BSA) from retrospectively electrocardiographically gated 64-slice cardiac computed tomography (CCT) by using automated analysis software in healthy adults. The study was approved by the institutional review board with a waiver of informed consent. Seventy-four healthy subjects (49% female, mean age 49.6±11) free of hypertension and hypercholesterolaemia with a normal CCT formed the study population. Analyses of LV and RV volume (end-diastolic, end-systolic and stroke volumes), function (ejection fraction), LV mass and inter-rater reproducibility were performed with commercially available analysis software capable of automated contour detection. General linear model analysis was performed to assess statistical significance by age group after adjustment for gender and BSA. Bland–Altman analysis assessed the inter-rater agreement. The reference range for LV and RV volume, function, and LV mass was normalised to age, gender and BSA. Statistically significant differences were noted between genders in both LV mass and RV volume (P-value<0.0001). Age, in concert with gender, was associated with significant differences in RV end-diastolic volume and LV ejection fraction (P-values 0.027 and 0.03). Bland–Altman analysis showed acceptable limits of agreement (±1.5% for ejection fraction) without systematic error. LV and RV volume, function and mass normalised to age, gender and BSA can be reported from CCT datasets, providing additional information important for patient management.

  14. Left Ventricular Diastolic Function and Characteristics in Fetal Aortic Stenosis

    Science.gov (United States)

    Friedman, Kevin G.; Schidlow, David; Freud, Lindsay; Escobar-Diaz, Maria; Tworetzky, Wayne

    2014-01-01

    Fetal aortic valvuloplasty (FAV) has shown promise in averting progression of mid-gestation aortic stenosis (AS) to hypoplastic left heart syndrome in a subset of patients. Patients who achieve biventricular circulation after FAV frequently have left ventricular (LV) diastolic dysfunction (DD). This study evaluates DD in fetuses with AS by comparing echocardiographic indices of LV diastolic function in fetuses undergoing FAV (n=20) to controls (n=40) and evaluates for LV factors associated with DD in FAV patients. We also compared pre- and post-FAV DD variables (n=16). Median gestational age (24 weeks, range 18–29 weeks) and fetal heart rate were similar between FAV and controls. Compared to controls, FAV patients had universally abnormal LV diastolic parameters including fused mitral inflow E and A waves (p=0.008), higher E velocity(p<0.001), shorter mitral inflow time (p=0.001), lower LV lateral annulus E′ (p<0.001), septal E′ (p=0.003) and higher E/E′ (p<0.001) than controls. FAV patients had abnormal right ventricular mechanics with higher tricuspid inflow E velocity (p<0.001), and shorter tricuspid inflow time (p=0.03). Worse LV diastolic function (lower LV E′) was associated with higher endocardial fibroelastosis (EFE) grade (r=0.74, p<0.001), large LV volume (r=0.55, p=0.013) and sphericity (r=0.58, P=0.009) and with lower LV pressure by mitral regurgitation jet (r=−0.68, p<0.001). Post-FAV, fewer patients had fused mitral inflow E and A than pre-FAV (p=0.05) and septal E′ was higher (=0.04). In conclusion, fetuses with mid-gestation AS have evidence of marked DD. Worse DD is associated with larger, more spherical LV, with more extensive EFE and lower LV pressure. PMID:24819899

  15. Resting early peak diastolic filling rate: a sensitive index of myocardial dysfunction in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Polak, J.F.; Kemper, A.J.; Bianco, J.A.; Parisi, A.F.; Tow, D.E.

    1982-01-01

    Resting first-pass radionuclide angiocardiography (RNA) was used to derive left-ventricular (LV) peak diastolic filling rates (PFR) in normals (Group 1:N . 12) and in patients with coronary artery disease (CAD), both without (Group 2:N . 27) and with previous myocardial infarction (Group 3:N . 23). Resting peak filling rates were significantly depressed in both Group 2 (1.61 +/- 0.36; p less than 0.01) and Group 3 (1:35 +/- 0.26; p less than 0.001) patients when compared with Group 1, normals (2.14 +/- 0.63). Even though LV systolic function of Group 2 patients was normal and comparable to that in Group 1 (EF . 0.55 +/- 0.06 against EF 0.55 +/- 0.06 NS), diastolic dysfunction [PFR less than 1.61 end diastolic volume/sec (EDV/sec)] was present at rest in 14 of 27 (52%). Depressed PFR values was also seen in 20 of 23 Group 3 patients (87%). It appears that (a) resting PFR is a sensitive and easily obtainable parameter of the diastolic dysfunction associated with CAD; (b) abnormal PFR values are seen in almost all patients with previous myocardial damage, and (c) a significant proportion of CAD patients without any evidence of abnormal systolic function have depressed resting PFR of the LV

  16. Exploratory assessment of left ventricular strain-volume loops in severe aortic valve diseases.

    Science.gov (United States)

    Hulshof, Hugo G; van Dijk, Arie P; George, Keith P; Hopman, Maria T E; Thijssen, Dick H J; Oxborough, David L

    2017-06-15

    Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long-term survival. Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions. In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ-volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction. We showed that our novel ԑ-volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction). Finally, we showed that the ԑ-volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. The purpose of this study was to examine left ventricular (LV) strain (ԑ)-volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty-seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four-chamber images to construct ԑ-volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ-volume relationship during systole (Sslope); end-systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ-diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were

  17. Feasibility of the left ventricular volume measurement by acoustic quantification method. Comparison with ultrafast computed tomography

    International Nuclear Information System (INIS)

    Tomimoto, Shigehiro; Nakatani, Satoshi; Tanaka, Norio; Uematsu, Masaaki; Beppu, Shintaro; Nagata, Seiki; Hamada, Seiki; Takamiya, Makoto; Miyatake, Kunio

    1995-01-01

    Acoustic quantification (AQ: the real-time automated boundary detection system) allows instantaneous measurement of cardiac chamber volumes. The feasibility of this method was evaluated by comparing the left ventricular (LV) volumes obtained with AQ to those derived from ultrafast computed tomography (UFCT), which enables accurate measurements of LV volumes even in the presence of LV asynergy, in 23 patients (8 with ischemic heart disease, 5 with cardiomyopathy, 3 with valvular heart disease). Both LV end-diastolic and end-systolic volumes obtained with the AQ method were in good agreement with those obtained with UFCT (y=1.04χ-16.9, r=0.95; y=0.87χ+15.7, r=0.91; respectively). AQ was reliable even in the presence of LV asynergy. Interobserver variability for the AQ measurement was 10.2%. AQ provides a new, clinically useful method for real-time accurate estimation of the left ventricular volume. (author)

  18. Feasibility of the left ventricular volume measurement by acoustic quantification method. Comparison with ultrafast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomimoto, Shigehiro; Nakatani, Satoshi; Tanaka, Norio; Uematsu, Masaaki; Beppu, Shintaro; Nagata, Seiki; Hamada, Seiki; Takamiya, Makoto; Miyatake, Kunio [National Cardiovascular Center, Suita, Osaka (Japan)

    1995-01-01

    Acoustic quantification (AQ: the real-time automated boundary detection system) allows instantaneous measurement of cardiac chamber volumes. The feasibility of this method was evaluated by comparing the left ventricular (LV) volumes obtained with AQ to those derived from ultrafast computed tomography (UFCT), which enables accurate measurements of LV volumes even in the presence of LV asynergy, in 23 patients (8 with ischemic heart disease, 5 with cardiomyopathy, 3 with valvular heart disease). Both LV end-diastolic and end-systolic volumes obtained with the AQ method were in good agreement with those obtained with UFCT (y=1.04{chi}-16.9, r=0.95; y=0.87{chi}+15.7, r=0.91; respectively). AQ was reliable even in the presence of LV asynergy. Interobserver variability for the AQ measurement was 10.2%. AQ provides a new, clinically useful method for real-time accurate estimation of the left ventricular volume. (author).

  19. Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography

    International Nuclear Information System (INIS)

    Vourvouri, E.C.; Poldermans, D.; Sianos, G.; Sozzi, F.B.; Schinkel, A.F.L.; Sutter, J. de; Roelandt, J.R.T.C.; Bax, J.J.; Parcharidis, G.; Valkema, R.

    2001-01-01

    The objective of this study was to perform a head-to-head comparison between two-dimensional (2D) echocardiography and gated single-photon emission computed tomography (SPET) for the evaluation of left ventricular (LV) function and volumes in patients with severe ischaemic LV dysfunction. Thirty-two patients with chronic ischaemic LV dysfunction [mean LV ejection fraction (EF) 25%±6%] were studied with gated SPET and 2D echocardiography. Regional wall motion was evaluated by both modalities and scored by two independent observers using a 16-segment model with a 5-point scoring system (1= normokinesia, 2= mild hypokinesia, 3= severe hypokinesia, 4= akinesia and 5= dyskinesia). LVEF and LV end-diastolic and end-systolic volumes were evaluated by 2D echocardiography using the Simpson's biplane discs method. The same parameters were calculated using quantitative gated SPET software (QGS, Cedars-Sinai Medical Center). The overall agreement between the two imaging modalities for assessment of regional wall motion was 69%. The correlations between gated SPET and 2D echocardiography for the assessment of end-diastolic and end-systolic volumes were excellent (r=0.94, P<0.01, and r=0.96, P<0.01, respectively). The correlation for LVEF was also good (r=0.83, P<0.01). In conclusion: in patients with ischaemic cardiomyopathy, close and significant relations between gated SPET and 2D echocardiography were observed for the assessment of regional and global LV function and LV volumes; gated SPET has the advantage that it provides information on both LV function/dimensions and perfusion. (orig.)

  20. E/e' Ratio: An Index of LV Filling Pressures Revisited

    Directory of Open Access Journals (Sweden)

    Sherif F. Nagueh

    2013-01-01

    Full Text Available There is a clinical need for the assessment of cardiac function in patients who present with symptoms and signs of pulmonary and systemic congestion. Echocardiography has been utilized over the years to answer this question. It is possible to study left ventricular (LV systolic and diastolic function as well as pulmonary artery pressures and right ventricular function using this technique. With respect to LV diastolic function, an ideal assessment includes evaluation of LV relaxation and LV filling pressures. There are several parameters that when properly acquired and analyzed can predict the 2 fundamental aspects noted above of LV diastolic function. The mitral annulus early diastolic recoil velocity (e’ recorded by tissue Doppler imaging (TDI was introduced as an index of LV relaxation. Further, e’ velocity is combined with mitral peak velocity E to predict LV filling pressures1. I will discuss the supporting literature for the last statement and point to the limitations in its application.

  1. Left ventricular ejection fraction and volumes as measured by 3D echocardiography and ultrafast computed tomography

    International Nuclear Information System (INIS)

    Vieira, Marcelo Luiz Campos; Nomura, Cesar H.; Tranchesi Junior, Bernardino; Oliveira, Wercules A. de; Naccarato, Gustavo; Serpa, Bruna S.; Passos, Rodrigo B.D.; Funari, Marcelo B. G.; Fischer, Claudio H.; Morhy, Samira S.

    2009-01-01

    Background: Real-time three-dimensional echocardiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. Objective: To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. Methods: Thirty nine consecutive patients (27 men, mean age of 57+- 12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT. LVEF and LV volumes were analyzed. Statistical analysis: coefficient of correlation (r: Pearson), Bland-Altman analysis, linear regression analysis, 95% CI, p 5 .58)%; end-diastolic volume ranged from 49.6 to 178.2 (87+-27.8) ml; end-systolic volume ranged from 11.4 to 78 (33.1+-13.6) ml. CT scan measurements: LVEF ranged from 53 to 86% (67.8+-7.78); end-diastolic volume ranged from 51 to 186 (106.5+-30.3) ml; end-systolic volume ranged from 7 to 72 (35.5+-13.4)ml. Correlations between RT-3D-Echo and CT were: LVEF (r: 0.7888, p<0.0001, 95% CI 0.6301 to 0.8843); end-diastolic volume (r: 0.7695, p<0.0001, 95% CI 0.5995 to 0.8730); end-systolic volume (r: 0.8119, p<0.0001, 95% CI 0.6673 to 0.8975). Conclusion: Good correlation between LVEF and ventricular volume parameters as measured by RT-3D-Echo and 64-slice ultrafast CT was found in the present case series. (author)

  2. Effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy: pressure-volume analysis with a nonimaging scintillation probe.

    Science.gov (United States)

    Bonow, R O; Ostrow, H G; Rosing, D R; Cannon, R O; Lipson, L C; Maron, B J; Kent, K M; Bacharach, S L; Green, M V

    1983-11-01

    To investigate the effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy, we studied 14 patients at catheterization with a nonimaging scintillation probe before and after serial intravenous infusions of low-, medium-, and high-dose verapamil (total dose 0.17 to 0.72 mg/kg). Percent change in radionuclide stroke counts after verapamil correlated well with percent change in thermodilution stroke volume (r = .87), and changes in diastolic and systolic counts were used to assess relative changes in left ventricular volumes after verapamil. Verapamil produced dose-related increases in end-diastolic counts (19 +/- 9% increase; p less than .001), end-systolic counts (91 +/- 54% increase; p less than .001), and stroke counts (7 +/- 10% increase; p less than .02). This was associated with a decrease in ejection fraction (83 +/- 8% control, 73 +/- 10% verapamil; p less than .001) and, in the 10 patients with left ventricular outflow tract gradients, a reduction in gradient (62 +/- 27 mm Hg control, 32 +/- 35 mm Hg verapamil; p less than .01). The end-systolic pressure-volume relation was shifted downward and rightward in all patients, suggesting a negative inotropic effect. In 10 patients, left ventricular pressure-volume loops were constructed with simultaneous micromanometer pressure recordings and the radionuclide time-activity curve. In five patients, verapamil shifted the diastolic pressure-volume curve downward and rightward, demonstrating improved pressure-volume relations despite the negative inotropic effect, and also increased the peak rate of rapid diastolic filling. In the other five patients, the diastolic pressure-volume relation was unaltered by verapamil, and increased end-diastolic volumes occurred at higher end-diastolic pressures; in these patients, the peak rate of left ventricular diastolic filling was not changed by verapamil. The negative inotropic effects of intravenous verapamil are

  3. Effects of Thyroid Hormone on Left Ventricular Volume and Function in Hyperthyroidism

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Koh, Chang Soon

    1983-01-01

    The purpose of this study is to investigate the effects of thyroid hormone on the left ventricular (LV) volume and function in man with untreated hyperthyroidism and to determine the effects of successful therapy for thyrotoxicosis on the ventricular pathophysiology. In the present study, equilibrium ralhianuclide cardiac angiography was performed and LV volume index, ejection phase indexes of LV performance, serum thyroid hormone levels and other hemodynamic parameters were measured in 28 normal subjects and 39 patients with hyperthyroidism before treatment and again every 4 weeks for the first 2 months after the initiation of effective therapy. The result obtained were as follows; 1) In the untreated hyperthyroid state heart rate, blood volume, cardiac index and stroke volume index (97±14 beats/min, 73.5±11.8 ml/kg, 6.9±1.4 l/min/m2 and 77.6±13.8 ml/m2, respectively) were increased significantly compared to those in normal control (74±12 beats/min, 65.6±14.8 ml/kg, 3.8±1.2 l/min/m2 and 56.6±13.2 ml/m2 respectively). (Mean±SD). 2) There was a significant increase in LV end-diastolic volume index in patients with hyperthyroidism (30.5±7.5 for hyperthyroid group compared to a normal control of 22.2±6.5; P<0.001), whereas end-systolic volume index remained unchanged 9.6±3.6 and 8.8±3.3 respectively. 3) In patients with hyperthyroidism, LV ejection fraction was 70.0±5.6%, fractional shortening 32.9±5.1%, mean velocity of circumferential fiber shortening (mean Vcf) 1.34±0.31 circ/sec and maximum ejection rate 3.47±0.80. All the ejection phase indexes were significantly greater than those in normal control (65.2±5.7%, 28.8±3.2%, 0.88±0.37 circ/sec and 2.27±0.50, respectively; p<0.001). 4) Effective therapy produced significant decrease in all the values of serum thyroid hormone concenrations (p<0.001), hemodynamic parameters (p<0.001), end-diastolic volume index (p<0.01) and ejection phase indexes of LV contractility in patients with hyperthyroidism

  4. Beneficial effects of elevating cardiac preload on left-ventricular diastolic function and volume during heat stress

    DEFF Research Database (Denmark)

    Brothers, R M; Pecini, Redi; Dalsgaard, Morten

    2014-01-01

    via volume loading while heat stressed would 1) increase indices of left ventricular diastolic function, and 2) preserve left ventricular end-diastolic volume (LVEDV) during a subsequent simulated hemorrhagic challenge induced by lower-body negative pressure (LBNP). Indices of left ventricular......Volume loading normalizes tolerance to a simulated hemorrhagic challenge in heat-stressed individuals, relative to when these individuals are thermoneutral. The mechanism(s) by which this occurs is unknown. This project tested two unique hypotheses; that is, the elevation of central blood volume...... diastolic function were evaluated in nine subjects during the following conditions: thermoneutral, heat stress, and heat stress after acute volume loading sufficient to return ventricular filling pressures toward thermoneutral levels. LVEDV was also measured in these subjects during the aforementioned...

  5. Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Mendoza Dorinna D

    2010-07-01

    Full Text Available Abstract Objectives To examine relationships between severity of echocardiography (echo -evidenced diastolic dysfunction (DD and volumetric filling by automated processing of routine cine cardiovascular magnetic resonance (CMR. Background Cine-CMR provides high-resolution assessment of left ventricular (LV chamber volumes. Automated segmentation (LV-METRIC yields LV filling curves by segmenting all short-axis images across all temporal phases. This study used cine-CMR to assess filling changes that occur with progressive DD. Methods 115 post-MI patients underwent CMR and echo within 1 day. LV-METRIC yielded multiple diastolic indices - E:A ratio, peak filling rate (PFR, time to peak filling rate (TPFR, and diastolic volume recovery (DVR80 - proportion of diastole required to recover 80% stroke volume. Echo was the reference for DD. Results LV-METRIC successfully generated LV filling curves in all patients. CMR indices were reproducible (≤ 1% inter-reader differences and required minimal processing time (175 ± 34 images/exam, 2:09 ± 0:51 minutes. CMR E:A ratio decreased with grade 1 and increased with grades 2-3 DD. Diastolic filling intervals, measured by DVR80 or TPFR, prolonged with grade 1 and shortened with grade 3 DD, paralleling echo deceleration time (p 80 identified 71% of patients with echo-evidenced grade 1 but no patients with grade 3 DD, and stroke-volume adjusted PFR identified 67% with grade 3 but none with grade 1 DD (matched specificity = 83%. The combination of DVR80 and PFR identified 53% of patients with grade 2 DD. Prolonged DVR80 was associated with grade 1 (OR 2.79, CI 1.65-4.05, p = 0.001 with a similar trend for grade 2 (OR 1.35, CI 0.98-1.74, p = 0.06, whereas high PFR was associated with grade 3 (OR 1.14, CI 1.02-1.25, p = 0.02 DD. Conclusions Automated cine-CMR segmentation can discern LV filling changes that occur with increasing severity of echo-evidenced DD. Impaired relaxation is associated with prolonged

  6. Left ventricular volume measurements with free breathing respiratory self-gated 3-dimensional golden angle radial whole-heart cine imaging - Feasibility and reproducibility.

    Science.gov (United States)

    Holst, Karen; Ugander, Martin; Sigfridsson, Andreas

    2017-11-01

    To develop and evaluate a free breathing respiratory self-gated isotropic resolution technique for left ventricular (LV) volume measurements. A 3D radial trajectory with double golden-angle ordering was used for free-running data acquisition during free breathing in 9 healthy volunteers. A respiratory self-gating signal was extracted from the center of k-space and used with the electrocardiogram to bin all data into 3 respiratory and 25 cardiac phases. 3D image volumes were reconstructed and the LV endocardial border was segmented. LV volume measurements and reproducibility from 3D free breathing cine were compared to conventional 2D breath-held cine. No difference was found between 3D free breathing cine and 2D breath-held cine with regards to LV ejection fraction, stroke volume, end-systolic volume and end-diastolic volume (Pcine and 2D breath-held cine (Pcine and conventional 2D breath-held cine showed similar values and test-retest repeatability for LV volumes in healthy volunteers. 3D free breathing cine enabled retrospective sorting and arbitrary angulation of isotropic data, and could correctly measure LV volumes during free breathing acquisition. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Modification of a Volume-Overload Heart Failure Model to Track Myocardial Remodeling and Device-Related Reverse Remodeling

    Science.gov (United States)

    Tuzun, Egemen; Bick, Roger; Kadipasaoglu, Cihan; Conger, Jeffrey L.; Poindexter, Brian J.; Gregoric, Igor D.; Frazier, O. H.; Towbin, Jeffrey A.; Radovancevic, Branislav

    2011-01-01

    Purpose. To provide an ovine model of ventricular remodeling and reverse remodeling by creating congestive heart failure (CHF) and then treating it by implanting a left ventricular assist device (LVAD). Methods. We induced volume-overload heart failure in 2 sheep; 20 weeks later, we implanted an LVAD and assessed recovery 11 weeks thereafter. We examined changes in histologic and hemodynamic data and levels of cellular markers of CHF. Results. After CHF induction, we found increases in LV end-diastolic pressure, LV systolic and diastolic dimensions, wall thickness, left atrial diameter, and atrial natriuretic protein (ANP) and endothelin-1 (ET-1) levels; β-adrenergic receptor (BAR) and dystrophin expression decreased markedly. Biopsies confirmed LV remodeling. After LVAD support, LV systolic and diastolic dimensions, wall thickness, and mass, and ANP and ET-1 levels decreased. Histopathologic and hemodynamic markers improved, and BAR and dystrophin expression normalized. Conclusions. We describe a successful sheep model for ventricular and reverse remodeling. PMID:22347659

  8. Left ventricular end-diastolic volume is decreased at maximal exercise in athletes with marked repolarisation abnormalities: a continuous radionuclide monitoring study

    International Nuclear Information System (INIS)

    Flotats, Albert; Camacho, Valle; Mena, Esther; Estorch, Montserrat; Tembl, Ana; Fuertes, Jordi; Carrio, Ignasi; Serra-Grima, Ricard; Borras, Xavier; Cinca, Juan

    2005-01-01

    Although marked repolarisation abnormalities (MRAs) are considered innocuous in trained athletes, their functional significance awaits clarification. The aim of this study was to further evaluate the pathophysiological implications of such MRAs. We compared left ventricular (LV) functional response to exhausting exercise in 39 male athletes with (n=22) or without (n=17) MRAs and with no structural cardiac abnormalities, by means of a portable radionuclide monitoring system (Vest, Capintec, Inc., Ramsey, NJ). MRAs were defined by the presence of negative T waves ≥2 mm in three or more rest ECG leads. The Vest data were averaged for 30 s and analysed at baseline and at different heart rate (HR) values (50%, 75%, 85%, 95% and 100% of peak HR), as well as at 2, 5 and 10 min of recovery. There were no significant differences in the effect of exhausting exercise between athletes with and athletes without MRAs. However, there was a significant difference in the trend in end-diastolic volume (EDV) during exercise depending upon the group of athletes considered (p=0.05). EDV differed significantly between the two groups of athletes at peak HR (p=0.031). EDV in athletes with MRAs was lower than that in athletes without MRAs (102%±7% vs 107%±8%, p=0.034). EDV is decreased at peak HR in athletes with MRAs. Such high HR values are infrequently achieved or maintained during sporting activities; therefore, in the absence of structural heart disease, MRAs should not preclude physical training and competitive availability. (orig.)

  9. Total average diastolic longitudinal displacement by colour tissue doppler imaging as an assessment of diastolic function

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sørensen, Tor; Søgaard, Peter

    2016-01-01

    of LD during early diastole and atrial contraction, can potentially be used as a simple and reliable alternative. METHODS: In 206 patients, using GE Healthcare Vivid E7 and 9 and Echopac BT11 software, we determined both diastolic LD, measured in the septal and lateral walls in the apical 4-chamber view...... by TDI, and the degree of diastolic dysfunction, based on current guidelines. Of these 206 patients, 157 had cardiac anomalies that could potentially affect diastolic LD such as severe systolic heart failure (n = 45), LV hypertrophy (n = 49), left ventricular (LV) dilation (n = 30), and mitral...... for the general discrimination of patients with or without diastolic dysfunction. Using linear regression, total average diastolic LD was estimated to fall by 2.4 mm for every increase in graded severity of diastolic dysfunction (β = -0.61, p-value

  10. Reduction in Left Ventricular Wall Stress and Improvement in Function in Failing Hearts using Algisyl-LVR

    Science.gov (United States)

    Lee, Lik Chuan; Zhihong, Zhang; Hinson, Andrew; Guccione, Julius M.

    2013-01-01

    Injection of Algisyl-LVR, a treatment under clinical development, is intended to treat patients with dilated cardiomyopathy. This treatment was recently used for the first time in patients who had symptomatic heart failure. In all patients, cardiac function of the left ventricle (LV) improved significantly, as manifested by consistent reduction of the LV volume and wall stress. Here we describe this novel treatment procedure and the methods used to quantify its effects on LV wall stress and function. Algisyl-LVR is a biopolymer gel consisting of Na+-Alginate and Ca2+-Alginate. The treatment procedure was carried out by mixing these two components and then combining them into one syringe for intramyocardial injections. This mixture was injected at 10 to 19 locations mid-way between the base and apex of the LV free wall in patients. Magnetic resonance imaging (MRI), together with mathematical modeling, was used to quantify the effects of this treatment in patients before treatment and at various time points during recovery. The epicardial and endocardial surfaces were first digitized from the MR images to reconstruct the LV geometry at end-systole and at end-diastole. Left ventricular cavity volumes were then measured from these reconstructed surfaces. Mathematical models of the LV were created from these MRI-reconstructed surfaces to calculate regional myofiber stress. Each LV model was constructed so that 1) it deforms according to a previously validated stress-strain relationship of the myocardium, and 2) the predicted LV cavity volume from these models matches the corresponding MRI-measured volume at end-diastole and end-systole. Diastolic filling was simulated by loading the LV endocardial surface with a prescribed end-diastolic pressure. Systolic contraction was simulated by concurrently loading the endocardial surface with a prescribed end-systolic pressure and adding active contraction in the myofiber direction. Regional myofiber stress at end-diastole and

  11. Diastolic Heart Failure

    OpenAIRE

    Wake, Ryotaro; Yoshikawa, Junichi; Yoshiyama, Minoru

    2012-01-01

    Primary diastolic failure is typically seen in patients with hypertensive or valvular heart disease as well as in hypertrophic or restrictive cardiomyopathy but can also occur in a variety of clinical disorders, especially tachycardia and ischemia. Diastolic dysfunction has a particularly high prevalence in elderly patients and is generally associated, with low mortality but high morbidity. The pathophysiology of diastolic dysfunction includes delayed relaxation, impaired LV filling and/or in...

  12. Evaluation of left ventricular mass in vitro and in vivo with MR imaging

    International Nuclear Information System (INIS)

    Mogelvang, J.; Thomsen, C.; Mehisen, J.; Henriksen, O.; Horn, T.

    1986-01-01

    The left ventricular (LV) mass was determined by MR multisection imaging in ten unopened postmortem human hearts and compared with the true weight of the isolated LV. In addition, the LV mass in 14 patients was determined by MR imaging. LV myocardial volume determined from acquisitions at end diastole were compared with the volume determined from acquisitions at end systole. The LV masses as determined on MR imaging showed excellent correlation with reference values (r = .99, P < .001). There was fine correlation between myocardial volume (mass) estimated in vivo in diastole and systole (r = .95, P < .0001). These results suggest that MR imaging is accurate for the determination of LV mass in vivo

  13. Normalised radionuclide measures of left ventricular diastolic function

    International Nuclear Information System (INIS)

    Lee, K.J.; Southee, A.E.; Bautovich, G.J.; Freedman, B.; McLaughlin, A.F.; Rossleigh, M.A.; Hutton, B.F.; Morris, J.G.; Royal Prince Alfred Hospital, Sydney

    1989-01-01

    Abnormal left ventricular diastolic function is being increasingly recognised in patients with clinical heart failure and normal systolic function. A simple routine radionuclide measure of diastolic function would therefore be useful. To establish, the relationship of peak diastolic filling rate (normalized for either end diastolic volume, stroke volume, or peak systolic emptying rate), and heart rate, age, and left ventricular ejection fraction was studied in 64 subjects with normal cardiovascular systems using routine gated heart pool studies. The peak filling rate when normalized to end diastolic volume correlated significantly with heart rate, age and left ventricular ejection fraction, whereas normalization to stroke volume correlated significantly to heart rate and age but not to left ventricular ejection fraction. Peak filling rate normalized for peak systolic emptying rate correlated with age only. Multiple regression equations were determined for each of the normalized peak filling rates in order to establish normal ranges for each parameter. When using peak filling rate normalized for end diastolic volume or stroke volume, appropriate allowance must be made for heart rate, age and ejection fraction. Peak filling rate normalized to peak ejection rate is a heart rate independent parameter which allows the performance of the patient's ventricle in diastole to be compared with its systolic function. It may be used in patients with normal systolic function to serially follow diastolic function, or if age corrected to screen for diastolic dysfunction. (orig.)

  14. Left ventricular diastolic function in type 2 diabetes mellitus and the association with coronary artery calcium score: a cardiac MRI study.

    Science.gov (United States)

    Graça, Bruno; Donato, Paulo; Ferreira, Maria João; Castelo-Branco, Miguel; Caseiro-Alves, Filipe

    2014-06-01

    The purpose of this study was to compare cardiac MRI-derived parameters of left ventricular (LV) diastolic function between uncomplicated type 2 diabetes mellitus (DM2) and normoglycemic control subjects and to evaluate whether these parameters of LV diastolic function are related to coronary atherosclerosis. We prospectively studied 41 subjects with DM2 and 21 normoglycemic control subjects (30 women and 32 men; mean age, 57.2 ± 7.1 [SD] years) with no evidence of overt cardiovascular disease. We used cardiac MRI to measure LV volumes, LV peak filling rate (PFR), and transmitral flow and CT to determine coronary artery calcium scores. Absolute values of the peak filling rate (PFR) were significantly lower in DM2 patients than in control subjects (mean ± SD, 293.2 ± 51.7 vs 375.7 ± 102.8 mL/s, respectively; p DM2 patients compared with control subjects. DM2 patients with coronary artery calcification showed a lower PFR normalized to stroke volume (SV) (mean ± SD, 4.4 ± 1.0 vs 5.3 ± 1.4, respectively; p = 0.038) and lower mitral peak E velocities (40.1 ± 11.3 vs 48.0 ± 7.3 cm/s; p = 0.024) than DM2 patients without coronary calcification. PFR normalized to SV was independently associated with the presence of coronary artery calcification (β = -1.5, p = 0.005). DM2 decreases cardiovascular MRI-derived parameters of LV diastolic function. Patients with DM2 and coronary atherosclerosis show a more impaired LV diastolic function than patients without coronary atherosclerosis.

  15. Overweight causes left ventricular diastolic asynchrony and diastolic dysfunction: a study based on speckle tracking echocardiography in healthy subjects.

    Science.gov (United States)

    Nakabachi, Masahiro; Mikami, Taisei; Okada, Kazunori; Onozuka, Hisao; Kaga, Sanae; Inoue, Mamiko; Yokoyama, Shinobu; Nishida, Mutsumi; Shimizu, Chikara; Matsuno, Kazuhiko; Iwano, Hiroyuki; Yamada, Satoshi; Tsutsui, Hiroyuki

    2012-09-01

    Left ventricular (LV) diastolic dysfunction is often observed in healthy subjects and can be a cause of heart failure with preserved ejection fraction (EF). We aimed to investigate the role of LV diastolic asynchrony as a cause of diastolic dysfunction in healthy subjects. In 40 healthy subjects, two-dimensional speckle tracking imaging (2DSTI) was performed to measure the peak early diastolic longitudinal strain rates (Esr) of the apical, mid-ventricular, and basal segments of the septum and posterior wall. A mean value of the Esr of the 6 segments (mEsr) was calculated. The time from aortic valve closure to the Esr was measured for each segment, and the standard deviation (SDTEsr) was calculated. The peak global early diastolic strain rate (gEsr) was measured with a region of interest (ROI) on the whole LV myocardium. LV flow propagation velocity (FPV) was measured using conventional Doppler techniques. SDTEsr was not correlated with age, but was significantly correlated with body mass index (BMI) (r = 0.41, p < 0.01). Although no significant correlation was observed between mEsr and FPV, gEsr and SDTEsr significantly correlated with FPV (r = 0.41, p < 0.01; r = -0.54, p < 0.001). As a result of the multiple regression analysis, SDTEsr was the single determinant of FPV. Diastolic asynchrony, associated with overweight but not with aging, may contribute to diastolic dysfunction in healthy subjects.

  16. Automatic detection of end-diastolic and end-systolic frames in 2D echocardiography.

    Science.gov (United States)

    Zolgharni, Massoud; Negoita, Madalina; Dhutia, Niti M; Mielewczik, Michael; Manoharan, Karikaran; Sohaib, S M Afzal; Finegold, Judith A; Sacchi, Stefania; Cole, Graham D; Francis, Darrel P

    2017-07-01

    Correctly selecting the end-diastolic and end-systolic frames on a 2D echocardiogram is important and challenging, for both human experts and automated algorithms. Manual selection is time-consuming and subject to uncertainty, and may affect the results obtained, especially for advanced measurements such as myocardial strain. We developed and evaluated algorithms which can automatically extract global and regional cardiac velocity, and identify end-diastolic and end-systolic frames. We acquired apical four-chamber 2D echocardiographic video recordings, each at least 10 heartbeats long, acquired twice at frame rates of 52 and 79 frames/s from 19 patients, yielding 38 recordings. Five experienced echocardiographers independently marked end-systolic and end-diastolic frames for the first 10 heartbeats of each recording. The automated algorithm also did this. Using the average of time points identified by five human operators as the reference gold standard, the individual operators had a root mean square difference from that gold standard of 46.5 ms. The algorithm had a root mean square difference from the human gold standard of 40.5 ms (P<.0001). Put another way, the algorithm-identified time point was an outlier in 122/564 heartbeats (21.6%), whereas the average human operator was an outlier in 254/564 heartbeats (45%). An automated algorithm can identify the end-systolic and end-diastolic frames with performance indistinguishable from that of human experts. This saves staff time, which could therefore be invested in assessing more beats, and reduces uncertainty about the reliability of the choice of frame. © 2017, Wiley Periodicals, Inc.

  17. Diastolic Backward-Traveling Decompression (Suction) Wave Correlates With Simultaneously Acquired Indices of Diastolic Function and Is Reduced in Left Ventricular Stunning.

    Science.gov (United States)

    Ladwiniec, Andrew; White, Paul A; Nijjer, Sukhjinder S; O'Sullivan, Michael; West, Nick E J; Davies, Justin E; Hoole, Stephen P

    2016-09-01

    Wave intensity analysis can distinguish proximal (propulsion) and distal (suction) influences on coronary blood flow and is purported to reflect myocardial performance and microvascular function. Quantifying the amplitude of the peak, backwards expansion wave (BEW) may have clinical utility. However, simultaneously acquired wave intensity analysis and left ventricular (LV) pressure-volume loop data, confirming the origin and effect of myocardial function on the BEW in humans, have not been previously reported. Patients with single-vessel left anterior descending coronary disease and normal ventricular function (n=13) were recruited prospectively. We simultaneously measured LV function with a conductance catheter and derived wave intensity analysis using a pressure-low velocity guidewire at baseline and again 30 minutes after a 1-minute coronary balloon occlusion. The peak BEW correlated with the indices of diastolic LV function: LV dP/dtmin (rs=-0.59; P=0.002) and τ (rs=-0.59; P=0.002), but not with systolic function. In 12 patients with paired measurements 30 minutes post balloon occlusion, LV dP/dtmax decreased from 1437.1±163.9 to 1299.4±152.9 mm Hg/s (median difference, -110.4 [-183.3 to -70.4]; P=0.015) and τ increased from 48.3±7.4 to 52.4±7.9 ms (difference, 4.1 [1.3-6.9]; P=0.01), but basal average peak coronary flow velocity was unchanged, indicating LV stunning post balloon occlusion. However, the peak BEW amplitude decreased from -9.95±5.45 W·m(-2)/s(2)×10(5) to -7.52±5.00 W·m(-2)/s(2)×10(5) (difference 2.43×10(5) [0.20×10(5) to 4.67×10(5); P=0.04]). Peak BEW assessed by coronary wave intensity analysis correlates with invasive indices of LV diastolic function and mirrors changes in LV diastolic function confirming the origin of the suction wave. This may have implications for physiological lesion assessment after percutaneous coronary intervention. URL: http://www.isrctn.org. Unique identifier: ISRCTN42864201. © 2016 American Heart

  18. Quantitative analysis of cardiac function: Comparison of electrocardiogram dual gated single photon emission tomography, planar radionuclide ventriculogram and contrast ventriculography in the determination of LV volume and ejection fraction

    Energy Technology Data Exchange (ETDEWEB)

    Ziada, G.; Abdel-Dayem, H.M.; Higazy, E.; Mohamed, M.M.; Bahar, R.; Hayat, N.; Yousof, A.M.

    1987-03-01

    A dual gated tomography (DGT) program for end systolic and end diastolic acquisition and subsequent processing for calculation of LVEF, end diastolic and end systolic volumes (EDV, ESV) has been evaluated in 20 healthy volunteers (25 years-40 years) and 45 patients (25 years-60 years): 20 with ischaemic heart disease and 25 with valvular heart disease (VHD). All had biplane multigated blood pool (MUGA) studies in the 40/sup 0/ LAO projection using in vivo /sup 99m/Tc-R BCs, immediately followed by DG. The results in the patients group were correlated with contrast ventriculography (CV). In the volunteer group, the normal values for LVEF, EDV and ESV measured with DGT were found to be 63%+10%, 91 ml + 6 ml and 30 ml + 6ml and r value for the LVEF=0.91 compared with MUGA. In the IHD group, r values compared with CV were 0.915 and 0.97 for the EDV and ESV and 0.934 for the LVEF. Compared with the MUGA, the r value for LVEF was 0.883. In the VHD group, r values were 0.98 for both the EDV and ESV and 0.948 for the LVEF (P<0.002) compared with CV and 0.789 for the LVEF compared with the MUGA. We feel that DGT is an accurate and reproducible technique for LV function measurements.

  19. Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods

    International Nuclear Information System (INIS)

    Montaudon, M.; Laffon, E.; Berger, P.; Corneloup, O.; Latrabe, V.; Laurent, F.

    2006-01-01

    This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method. (orig.)

  20. Usefulness of acoustic quantification method in left ventricular volume and ejection fraction. Compared with ventriculography and scintigraphy

    International Nuclear Information System (INIS)

    Shibata, Takahiro; Honda, Youichi; Kashiwagi, Hidehiko

    1996-01-01

    Acoustic quantification method (AQ: on-line automated boundary detection system) has proved to have a good correlation with left ventriculography (LVG) and scintigraphy (SG) in patients with normal left ventricular (LV) function. The aim of this study is to determine whether AQ is also useful in patients with abnormal LV function. We examined 54 patients with LV asynergy. End-diastolic volumes with AQ, LVG and SG were 77, 135, 118 ml. A good correlation was found between AQ and LVG and SG (LVG; r=0.81, SG; r=0.68). End-systolic volumes with AQ, LVG and SG were 38, 64 and 57 ml. Left ventricular volumes obtained from AQ had a good correlation with LVG and SG, but were underestimated. LV ejection fraction obtained from AQ had good correlation with those with LVG and SG (LVG; r=0.84. SG; r=0.77). On-line AQ appears to be a useful noninvasive method for evaluation of the left ventricular ejection fraction, but care must be exercised when estimations of left ventricular volumes are made. (author)

  1. Reduced left ventricular filling following blood volume extraction does not result in compensatory augmentation of cardiac mechanics.

    Science.gov (United States)

    Lord, Rachel; MacLeod, David; George, Keith; Oxborough, David; Shave, Rob; Stembridge, Mike

    2018-04-01

    What is the central question of this study? A reduction in left ventricular (LV) filling, and concomitant increase in heart rate, augments LV mechanics to maintain stroke volume (SV); however, the impact of reduced LV filling in isolation on SV and LV mechanics is currently unknown. What is the main finding and its importance? An isolated decrease in LV filling did not provoke a compensatory increase in mechanics to maintain SV; in contrast, LV mechanics and SV were reduced. These data indicate that when LV filling is reduced without changes in heart rate, LV mechanics do not compensate to maintain SV. An acute non-invasive reduction in preload has been shown to augment cardiac mechanics to maintain stroke volume and cardiac output. Such interventions induce concomitant changes in heart rate, whereas blood volume extraction reduces preload without changes in heart rate. Therefore, the purpose of this study was to determine whether a preload reduction in isolation resulted in augmented stroke volume achieved via enhanced cardiac mechanics. Nine healthy volunteers (four female, age 29 ± 11 years) underwent echocardiography for the assessment of left ventricular (LV) volumes and mechanics in a supine position at baseline and end extraction after the controlled removal of 25% of total blood volume (1062 ± 342 ml). Arterial blood pressure was monitored continuously by a pressure transducer attached to an indwelling radial artery catheter. Heart rate and total peripheral resistance were unchanged from baseline to end extraction, but systolic blood pressure was reduced (from 148 to 127 mmHg). From baseline to end extraction there were significant reductions in left ventricular end-diastolic volume (from 89 to 71 ml) and stroke volume (from 56 to 37 ml); however, there was no change in LV twist, basal or apical rotation. In contrast, LV longitudinal strain (from -20 to -17%) and basal circumferential strain (from -22 to -19%) were significantly reduced from

  2. Validity of automated measurement of left ventricular ejection fraction and volume using the Philips EPIQ system.

    Science.gov (United States)

    Hovnanians, Ninel; Win, Theresa; Makkiya, Mohammed; Zheng, Qi; Taub, Cynthia

    2017-11-01

    To assess the efficiency and reproducibility of automated measurements of left ventricular (LV) volumes and LV ejection fraction (LVEF) in comparison to manually traced biplane Simpson's method. This is a single-center prospective study. Apical four- and two-chamber views were acquired in patients in sinus rhythm. Two operators independently measured LV volumes and LVEF using biplane Simpson's method. In addition, the image analysis software a2DQ on the Philips EPIQ system was applied to automatically assess the LV volumes and LVEF. Time spent on each analysis, using both methods, was documented. Concordance of echocardiographic measures was evaluated using intraclass correlation (ICC) and Bland-Altman analysis. Manual tracing and automated measurement of LV volumes and LVEF were performed in 184 patients with a mean age of 67.3 ± 17.3 years and BMI 28.0 ± 6.8 kg/m 2 . ICC and Bland-Altman analysis showed good agreements between manual and automated methods measuring LVEF, end-systolic, and end-diastolic volumes. The average analysis time was significantly less using the automated method than manual tracing (116 vs 217 seconds/patient, P Automated measurement using the novel image analysis software a2DQ on the Philips EPIQ system produced accurate, efficient, and reproducible assessment of LV volumes and LVEF compared with manual measurement. © 2017, Wiley Periodicals, Inc.

  3. Left ventricular mechanical adaptation to chronic aortic regurgitation in intact dogs

    International Nuclear Information System (INIS)

    Florenzano, F.; Glantz, S.A.

    1987-01-01

    Increased and end-diastolic wall stress has been hypothesized to stimulate left ventricular (LV) hypertrophy following volume overload. The authors instrumented intact-chest dogs with radiopaque markers in both ventricles and created volume overload by puncturing one aortic valve cusp. An x-ray system with biplane fluoroscopic and cineradiographic capabilities was used. End-diastolic stress increased immediately, then fell over 3 mo as the heart hypertrophied. End-systolic stress did not change significantly. Chamber contractility, quantified as E/sub max/, the end-systolic pressure-volume line slope, increased. E/sub max/ normalized by multiplying by LV mass increased following the lesion before but not after β-blockade with propranolol and did not change significantly over time, suggesting that chamber contractility changed because of increased mass and sympathetic tone rather than changed intrinsic muscle function. LV mass did not initially correlate with lesion size, but steady-state mass did. Over the range of lesions the authors produced, increased end-diastolic wall stress appears to stimulate hypertrophy at a fixed rate, which stops when end-diastolic wall stress has been reduced to an acceptable level

  4. Atrial function, atrial volume and cardiovascular clinical outcomes in patients with end-stage renal disease - A study of cardiac computed tomography

    DEFF Research Database (Denmark)

    Rasmussen, Laust Dupont; Winther, Simon; Jørgensen, Hanne Skou

    2017-01-01

    and mortality data were extracted from the Western Denmark Heart Registry, a review of patient records and patient interviews. RESULTS: Baseline patient characteristics did not differ between LAEDV tertiles. LAEDV was positively associated with measures of LV function - both LVEDV (β = 0.36, p ... mass (β = 0.30, p positively and LAEF negatively associated with NT-PRO-BNP (LAEDV: β = 10.28, p patients died and 19 (16.2%) patients suffered......BACKGROUND: Patients with chronic kidney disease (CKD) have an increased risk of cardiovascular events. Previous studies using 2-dimensional echocardiography show that left atrial end-diastolic volume (LAEDV) predicts cardiovascular outcomes and mortality in patients with CKD. However, contrast...

  5. Relationship between left ventricular diastolic function and myocardial sympathetic denervation measured by {sup 123}I-meta-iodobenzylguanidine imaging in Anderson-Fabry disease

    Energy Technology Data Exchange (ETDEWEB)

    Spinelli, Letizia; Giudice, Caterina Anna; Imbriaco, Massimo; Trimarco, Bruno; Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Pellegrino, Teresa [Institute of Biostructure and Bioimaging, National Council of Research, Naples (Italy); Pisani, Antonio; Riccio, Eleonora [University Federico II, Department of Public Health, Naples (Italy); Salvatore, Marco [IRCCS SDN, Naples (Italy)

    2016-04-15

    Whether cardiac sympathetic nervous function abnormalities may be present in patients with Anderson-Fabry disease (AFD) remains unexplored. We investigated the relationship between left ventricular (LV) function and cardiac sympathetic nervous function in patients with AFD. Twenty-five patients (12 men, mean age 43 ± 13 years) with genetically proved AFD and preserved LV ejection fraction and ten age and gender-matched control subjects underwent speckle tracking echocardiography and {sup 123}I-meta-iodobenzylguanidine (MIBG) imaging from which early and late heart to mediastinum (H/M) ratios and myocardial washout rate values were calculated. In AFD patients, a significant correlation between late H/M ratio and LV mass index (r = -61, p = 0.001), left atrial volume (r = -0.72, p < 0.001), systolic pulmonary artery pressure (r = -0.75, p < 0.001), and early diastolic untwisting rate (r = -0.66, p < 0.001) was found. Ten AFD patients exhibited a late H/M ratio below two fold standard deviation of control subjects (≤1.75). Patients showing late H/M ratio ≤ 1.75 had significantly higher LV mass index, relative wall thickness, left atrial volume and systolic pulmonary artery pressure, lower systolic longitudinal strain and an early diastolic untwisting rate compared to patients with late H/M ratio > 1.75. At multivariable linear regression analysis, early diastolic untwisting rate was the only independent predictor of late H/M ratio ≤ 1.75 (odds ratio 1.15, 95 % confidence interval 1.07-1.31, p < 0.05). The present findings provide the first demonstration of a cardiac sympathetic derangement in AFD patients with preserved LV ejection fraction, which is mostly related to LV diastolic dysfunction. (orig.)

  6. Relation Between Pressure and Volume Unloading During Ramp Testing in Patients Supported with a Continuous-Flow Left Ventricular Assist Device

    DEFF Research Database (Denmark)

    Jung, Mette H; Hassager, Christian; Balling, Louise

    2015-01-01

    Pulmonary capillary wedge pressure (PCWP) is the key to describing left ventricular (LV) unloading, however, the relation between pressure and the echocardiography-derived surrogate of LV volume (left ventricular end-diastolic diameter (LVEDD)) as a function of pump speed (RPM) in continuous......-flow left ventricular assist device (CF-LVAD) patients is unknown. In this study the pressure-volume relationship as a function of RPM during ramp testing was investigated by simultaneously measuring PCWP by Swan-Ganz catheter and LVEDD by echocardiography. The ramp protocol started at usual pump setting...

  7. Exploratory assessment of left ventricular strain–volume loops in severe aortic valve diseases

    Science.gov (United States)

    Hulshof, Hugo G.; van Dijk, Arie P.; George, Keith P.; Hopman, Maria T. E.; Thijssen, Dick H. J.

    2017-01-01

    Key points Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long‐term survival.Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions.In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ–volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction.We showed that our novel ԑ–volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction).Finally, we showed that the ԑ–volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. Abstract The purpose of this study was to examine left ventricular (LV) strain (ԑ)–volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty‐seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four‐chamber images to construct ԑ–volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ–volume relationship during systole (Sslope); end‐systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ–diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects

  8. Vortex-ring mixing as a measure of diastolic function of the human heart: Phantom validation and initial observations in healthy volunteers and patients with heart failure.

    Science.gov (United States)

    Töger, Johannes; Kanski, Mikael; Arvidsson, Per M; Carlsson, Marcus; Kovács, Sándor J; Borgquist, Rasmus; Revstedt, Johan; Söderlind, Gustaf; Arheden, Håkan; Heiberg, Einar

    2016-06-01

    To present and validate a new method for 4D flow quantification of vortex-ring mixing during early, rapid filling of the left ventricle (LV) as a potential index of diastolic dysfunction and heart failure. 4D flow mixing measurements were validated using planar laser-induced fluorescence (PLIF) in a phantom setup. Controls (n = 23) and heart failure patients (n = 23) were studied using 4D flow at 1.5T (26 subjects) or 3T (20 subjects) to determine vortex volume (VV) and inflowing volume (VVinflow ). The volume mixed into the vortex-ring was quantified as VVmix-in = VV-VVinflow . The mixing ratio was defined as MXR = VVmix-in /VV. Furthermore, we quantified the fraction of the end-systolic volume (ESV) mixed into the vortex-ring (VVmix-in /ESV) and the fraction of the LV volume at diastasis (DV) occupied by the vortex-ring (VV/DV). PLIF validation of MXR showed fair agreement (R(2) = 0.45, mean ± SD 1 ± 6%). MXR was higher in patients compared to controls (28 ± 11% vs. 16 ± 10%, P Vortex-ring mixing can be quantified using 4D flow. The differences in mixing parameters observed between controls and patients motivate further investigation as indices of diastolic dysfunction. J. Magn. Reson. Imaging 2016;43:1386-1397. © 2015 Wiley Periodicals, Inc.

  9. Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction.

    Science.gov (United States)

    Goo, Hyun Woo; Park, Sang-Hyub

    2015-12-01

    To assess agreement between two semi-automatic, three-dimensional (3D) computed tomography (CT) ventricular volumetry methods with different user interactions in patients with congenital heart disease. In 30 patients with congenital heart disease (median age 8 years, range 5 days-33 years; 20 men), dual-source, multi-section, electrocardiography-synchronized cardiac CT was obtained at the end-systolic (n = 22) and/or end-diastolic (n = 28) phase. Nineteen left ventricle end-systolic (LV ESV), 28 left ventricle end-diastolic (LV EDV), 22 right ventricle end-systolic (RV ESV), and 28 right ventricle end-diastolic volumes (RV EDV) were successfully calculated using two semi-automatic, 3D segmentation methods with different user interactions (high in method 1, low in method 2). The calculated ventricular volumes of the two methods were compared and correlated. A P value volumetry shows good agreement and high correlation between the two methods, but method 2 tends to slightly underestimate LV ESV, LV EDV, and RV ESV.

  10. Relationship of carotid arterial functional and structural changes to left atrial volume in untreated hypertension.

    Science.gov (United States)

    Jaroch, Joanna; Rzyczkowska, Barbara; Bociąga, Zbigniew; Vriz, Olga; Driussi, Caterina; Loboz-Rudnicka, Maria; Dudek, Krzysztof; Łoboz-Grudzień, Krystyna

    2016-04-01

    The contribution of arterial functional and structural changes to left ventricular (LV) diastolic dysfunction has been the area of recent research. There are some studies on the relationship between arterial stiffness (a.s.) and left atrial (LA) remodelling as a marker of diastolic burden. Little is known about the association of arterial structural changes and LA remodelling in hypertension (H). The aim of this study was to examine the relationship between carotid a.s. and intima-media thickness (IMT) and LA volume in subjects with H. The study included 245 previously untreated hypertensives (166 women and 79 men, mean age 53.7 ± 11.8 years). Each patient was subjected to echocardiography with measurement of LA volume, evaluation of left ventricular hypertrophy (LVH) and LV systolic/diastolic function indices, integrated assessment of carotid IMT and echo-tracking of a.s. and wave reflection parameters. Univariate regression analysis revealed significant correlations between indexed LA volume and selected clinical characteristics, echocardiographic indices of LVH and LV diastolic/systolic function and a.s./wave reflection parameters. The following parameters were identified as independent determinants of indexed LA volume on multivariate regression analysis: diastolic blood pressure (beta = -0.229, P arterial stiffness but not intima-media thickness and LA volume in patients with untreated hypertension.

  11. CARDIAC STRUCTURAL AND FUNCTIONAL ABNORMALITIES IN FEMALES WITH UNTREATED HYPOPITUITARISM DUE TO SHEEHAN SYNDROME: RESPONSE TO HORMONE REPLACEMENT THERAPY.

    Science.gov (United States)

    Laway, Bashir Ahmad; Ramzan, Mahroosa; Allai, Mohd Sultan; Wani, Arshad Iqbal; Misgar, Raiz Ahmad

    2016-09-01

    Data on cardiac abnormalities in females with untreated hypopituitarism are limited. We investigated echocardiographic abnormalities in females with untreated hypopituitarism and their response to treatment. Twenty-three females with treatment-naïve hypopituitarism and 30 matched healthy controls were evaluated for cardiac structure and function. Echocardiographic evaluation was done at presentation and after achieving a euthyroid and eucortisol state. Fourteen (61%) patients had mitral regurgitation, and 11 (48%) had pericardial effusion as against none among controls. Indices of left ventricular (LV) size like LV end diastolic dimension (LVEDD; 44.5 ± 3.5 mm in cases vs. 47.6 ± 3.8 mm in controls, P = .004), and LV diastolic volume (LVEDV; 91.8 ± 18.0 mL versus 106.5 ± 20.4 mL, P = .009) were significantly lower in the SS group compared with controls. LV mass (LVM) was 70.8 ± 19.2 g in cases and 108.0 ± 33.2 g in controls (P = .02). Similarly, indices of LV systolic function like stroke volume (SV; 59.1 ± 12.0 mL in cases and 74.4 ± 15.8 mL in controls; P = .000), ejection fraction (EF; 64.3 ± 6.2 % in cases against 69.9 ± 9.2 % in controls; P = .03), and fractional shortening (FS; 34.9 ± 4.7% versus 40.1 ± 4.4%, P = .000) were significantly decreased in patients compared with controls. Cardiac abnormalities normalized with restoration of a euthyroid and eucortisol state. Pericardial effusion, mitral regurgitation, and diminished LVM are common in females with untreated hypopituitarism. ACTH = adrenocorticotrophic hormone BMI = body mass index DT = deceleration time EDV = end-diastolic volume EF = ejection fraction FS = fractional shortening GH = growth hormone IGF-1 = insulin growth factor-1 ITT = insulin tolerance test IVSd = interventricular septal diameter LH = luteinizing hormone LV = left ventricular LVEDD = LV end diastolic dimension LVEDV = LV end diastolic volume LVM = LV mass MRI = magnetic resonance imaging MVP = mitral value prolapse PPH

  12. Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography

    International Nuclear Information System (INIS)

    Pai, Moon Sun; Yang, You Jung; Im, Ki Chun; Hong, Il Ki; Yun, Sung Cheol; Kang, Duk Hyun; Song, Jae Kwan; Moon, Dae Hyuk

    2005-01-01

    Systemic errors in the gated single photon emission computed tomography (SPECT) measurement of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) may occur. We evaluated whether patient-related factors affected the accuracy of EDV, ESV, and EF measured by electrocardiogram-gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. EDV, ESV, and EF were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated EDV and ESV, and overestimated EF, but 4D-MSPECT overestimated all those values (p<0.001). Independent variables that increased the difference in EDV between echocardiography and gated SPECT were decreasing LV end-diastolic wall thickness, decreasing body surface area, female sex and increasing EDV (p< 0.001). Those for ESV were decreasing LV end-systolic wall thickness, female sex, and decreasing ESV (p<0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in EF (p< 0.001). Adenosine stress SPECT showed significantly higher EDV and ESV values and a lower EF than did redistribution SPECT (p< 0.001). In determination of EF, QGS demonstrated a smaller bias than did 4D-MSPECT. However, in men with LV hypertrophy, 4D-MSPECT was superior to QGS. Systemic error by gated Tl-201 SPECT is determined by individual patient-characteristics

  13. Types of Diastolic Dysfunction of the Left Ventricle in Adolescents with Myocardial Pathology

    Directory of Open Access Journals (Sweden)

    L.F. Bogmat

    2014-05-01

    Full Text Available In adolescents with myocardial pathology during isometric tests we detected three types of diastolic dysfunction of the left ventricle (LV of the heart, depending on E/A ratio. The most pronounced signs of diastolic filling disorders were detected in the third group of patients, as evidenced: by a tendency to increase isovolumic relaxation time, a significant increase of slowing down time of the first phase of left ventricular filling, reduced LV filling rate both in the first phase of the passive filling and the second phase of active LV filling, increasing E/A ratio of more than 2, significant dilation of the left atrium, as well as positive increase in diastolic reserve that confirms deeper diastolic dysfunction in these adolescents compared with other subgroups.

  14. Prognostic implications of left ventricular diastolic dysfunction with preserved systolic function following acute myocardial infarction

    DEFF Research Database (Denmark)

    Poulsen, S H; Møller, J E; Nørager, B

    2001-01-01

    of the mitral and pulmonary venous flow, and the propagation velocity of early mitral flow by color M-mode Doppler echocardiography in 183 consecutive patients at day 5-7 following their first acute MI. Patients were classified into four groups: group A: preserved LV systolic and diastolic function (n = 73......%) and D (38%) compared to A (2%) (p class >or=II (p = 0.006), and age (0.008) as predictors of cardiac death or readmission due to heart failure. The presence of LV diastolic dysfunction with preserved......The contribution of diastolic dysfunction in patients with preserved left ventricular (LV) systolic function to impaired functional status and cardiac mortality in myocardial infarction (MI) is unknown. In the present study, assessment of LV diastolic function was performed by Doppler analysis...

  15. Is the presence of end-diastolic forward flow specific for restrictive right ventricular physiology in repaired tetralogy of Fallot?

    Science.gov (United States)

    Mori, Yoshiki; Murakami, Tomotaka; Inoue, Nao; Kaneko, Sachie; Nakashima, Yasumi; Koide, Masaaki

    2017-08-01

    End-diastolic forward flow (EDFF) is recognized as restrictive right ventricular physiology (r-RVP), but conflicting results have been reported about effects on the clinical outcome in repaired tetralogy of Fallot (r-TOF). We hypothesized that the EDFF by Doppler was not specific for diagnosing r-RVP. Sixty-two consecutive patients aged 15.7±11.6years who underwent cardiac catheterization were studied. Patients were divided according to the presence of EDFF (group 1: EDFF+, group 2: EDFF-) and RV size (group A: small RV, group B: large RV [>150ml/m 2 ]). Group 1 (n=23) had higher a right atrial pressure (RAP), pressure gradient between the RAP and pulmonary diastolic pressure (PDP), and atrial natriuretic peptide (ANP) levels than group 2. Four patients (17.4%) in group 1 and 89.7% of patients in group 2 had a normal RAP range (a wave<10mmHg). There were no differences in the RV volume, ejection fraction (EF), B-type natriuretic peptide levels, and severity of pulmonary regurgitation (PR) between groups 1 and 2. Group A had better RV and LVEF than group B, as well as a smaller LV size. The RAP in subgroup 1A was higher than that of the other 3 subgroups. Subgroup 1B had a similar RAP to group 2, and a lower PDP and a more severe PR than subgroup 1A. Patients with EDFF are associated with increased ANP levels. The presence of EDFF may not be specific for r-RVP, since it is observed in some TOF patients with low PDP (severe PR) and normal RAP. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Evaluation of left ventricular function and volume in patients with dilated cardiomyopathy: Gated myocardial single-photon emission tomography (SPECT) versus echocardiography

    International Nuclear Information System (INIS)

    Berk, Fatma; Isgoren, S.; Demir, H.; Kozdag, G.; Ural, D.; Komsuoglu, B.

    2005-01-01

    Left ventricular function, volumes and regional wall motion provide valuable diagnostic information and are of long-term prognostic importance in patients with dilated cardiomyopathy (DCM). This study was designed to compare the effectiveness of 2D-echocardiography and gated single-photon emission tomography (SPECT) for evaluation of these parameters in patients with DCM. Gated SPECT and 2D-echocardiography were performed in 33 patients having DCM. Gated SPECT data, including left ventricular ejection fraction (LVEF), were processed using an automated algorithm. Standard technique was used for 2D-echocardiography. Regional wall motion was evaluated using both modalities and was scored by two independent observers using a 16-sement model with a 5-point scoring system. The overall agreement between the two imaging modalities for the assessment of regional wall motion was 56% (298/528 segments). With gated SPECT, LEVF, end-diastolic volume (EDV), and end-diastolic volume (EDV), and end-systolic volume (ESV) were 27+-9%, 217+-73mL, respectively, and 30.8%, 195+-58mL and, 137+-48 mL with echocardiography. The correlation between gated SPECT and 2-D-echocardiography was good (r=0.76, P<0.01) for the assessment of LVEF. The correlation for EDV and ESV were also good, but with wider limits of agreement (r=0.72, P<0.01 and r=0.73, P<0.01, respectively) and significantly higher values were obtained with gated SPECT (P<0.01). Gated SPECT and 2D-echocardiography correlate well for the assessment of LV function and LV volumes. Like 2D-echocardiography, gated SPECT provides reliable information about LV function and dimension with the additional advantage of perfusion data. (author)

  17. Changes with age in left ventricular function and volumes at rest and postexercise in postmenopausal women

    International Nuclear Information System (INIS)

    Yamada, Kiyoyasu; Isobe, Satoshi; Hirai, Makoto

    2006-01-01

    In postmenopausal women, it has been reported that the plasma estrogen levels diminish immediately after menopause, and that this phenomenon affects left ventricular (LV) function and volumes. However, the effects of age on LV function and volumes for a relatively short period in the postmenopausal women remain to be established. Electrocardiographically gated-myocardial single-photon emission computed tomography (SPECT) has recently provided accurate estimations of perfusion, cardiac systolic and diastolic functions. We investigated the age-related changes in LV function and volumes in postmenopausal women using electrocardiographically gated-myocardial scintigraphy. Twenty-two consecutive healthy postmenopausal women (mean age of 63.8±9.4 years, from 42 to 77 years) without cardiac disease underwent stress/rest technetium-99m tetrofosmin gated-myocardial SPECT with 16 frames per cardiac cycle at baseline and follow-up (1.0±0.3 years later). LV ejection fraction (LVEF) and LV volumes were calculated by quantitative gated SPECT (QGS) software. Fourier series were retained for the analysis of the volume curve. From this volume curve, we derived the following diastolic indices: peak filling rate (PFR) and time to PFR (TPFR). End-systolic volume index (ESVI) significantly decreased at postexercise (p=0.02) and tended to decrease at rest (p=0.06) from the baseline to the follow-up study. LVEF significantly increased at both postexercise (p=0.01) and rest (p=0.03) from the baseline to the follow-up study. The TPFR at rest tended to be prolonged from the baseline to the follow-up study (p=0.07). The absolute increase in LVEF at postexercise tended to decrease with age [4.8% (50s) vs. 3.4% (60s) vs. 1.2% (70s)]. An age-related change in cardiac performance is apparent at an approximately 1 year follow-up in postmenopausal women. In particular, the increase in LV systolic function tends to show the greatest value in the 50s subjects among the 3 generations. (author)

  18. Relationship between myocardial extracellular space expansion estimated with post-contrast T1 mapping MRI and left ventricular remodeling and neurohormonal activation in patients with dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji Hyun; Son, Jung Woo; Chung, Hye Moon [Cardiology Division, Dept. of Internal Medicine, Yonsei University College of Medicine, Seoul (Korea, Republic of); and others

    2015-10-15

    Post-contrast T1 values are closely related to the degree of myocardial extracellular space expansion. We determined the relationship between post-contrast T1 values and left ventricular (LV) diastolic function, LV remodeling, and neurohormonal activation in patients with dilated cardiomyopathy (DCM). Fifty-nine patients with DCM (mean age, 55 ± 15 years; 41 males and 18 females) who underwent both 1.5T magnetic resonance imaging and echocardiography were enrolled. The post-contrast 10-minute T1 value was generated from inversion time scout images obtained using the Look-Locker inversion recovery sequence and a curve-fitting algorithm. The T1 sample volume was obtained from three interventricular septal points, and the mean T1 value was used for analysis. The N-Terminal pro-B-type natriuretic peptide (NT-proBNP) level was measured in 40 patients. The mean LV ejection fraction was 24 ± 9% and the post-T1 value was 254.5 ± 46.4 ms. The post-contrast T1 value was significantly correlated with systolic longitudinal septal velocity (s'), peak late diastolic velocity of the mitral annulus (a'), the diastolic elastance index (Ed, [E/e']/stroke volume), LV mass/volume ratio, LV end-diastolic wall stress, and LV end-systolic wall stress. In a multivariate analysis without NT-proBNP, T1 values were independently correlated with Ed (β = -0.351, p = 0.016) and the LV mass/volume ratio (β = 0.495, p = 0.001). When NT-proBNP was used in the analysis, NT-proBNP was independently correlated with the T1 values (β = -0.339, p = 0.017). Post-contrast T1 is closely related to LV remodeling, diastolic function, and neurohormonal activation in patients with DCM.

  19. Left ventricular diastolic function is associated with symptom status in severe aortic valve stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Christensen, Nicolaj L; Videbæk, Lars

    2014-01-01

    atrial volume index, and deceleration time were still associated with the presence of symptoms. CONCLUSIONS: The present study demonstrates that symptomatic status in severe AS is associated with impaired diastolic function, LV hypertrophy, concentric remodeling, and left atrial dilatation when corrected...... function, and left atrial dilatation compared with asymptomatic patients. METHODS AND RESULTS: In a retrospective descriptive study, we compared clinical characteristics and echocardiographic parameters in 99 symptomatic and 139 asymptomatic patients with severe AS and LV ejection fraction ≥50.......001), and had a lower prevalence of hypertension (73% versus 40%; Ptime (199±58 versus...

  20. Interaction of Left Ventricular Size and Sex on Outcome of Cardiac Resynchronization Therapy Among Patients With a Narrow QRS Duration in the EchoCRT Trial

    DEFF Research Database (Denmark)

    Varma, Niraj; Sogaard, Peter; Bax, Jeroen J

    2018-01-01

    BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac Resynchroniz......BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac...... Resynchronization Therapy) trial enrolling patients with heart failure with QRSd New York Heart Association class III, QRSd

  1. Effects of long-term adrenergic beta-blockade on left ventricular diastolic filling in patients with acute myocardial infarction

    DEFF Research Database (Denmark)

    Poulsen, S H; Jensen, S E; Egstrup, K

    1999-01-01

    BACKGROUND: Left ventricular (LV) systolic and diastolic function are known to be affected in the wake of a myocardial infarction (MI). beta-Adrenergic blocking agents have demonstrated improvement of LV systolic and diastolic function in patients with dilated cardiomyopathy and theoretically would...... have same beneficial effects in MI. beta-Adrenergic blocking agents are widely used in MI; however only few reports on changes of LV systolic and diastolic function during long-term treatment after acute MI are available. METHODS: Two-dimensional and Doppler echocardiography were used to evaluate LV...

  2. The ratio of right ventricular volume to left ventricular volume reflects the impact of pulmonary regurgitation independently of the method of pulmonary regurgitation quantification

    International Nuclear Information System (INIS)

    Śpiewak, Mateusz; Małek, Łukasz A.; Petryka, Joanna; Mazurkiewicz, Łukasz; Miłosz, Barbara; Biernacka, Elżbieta K.; Kowalski, Mirosław; Hoffman, Piotr; Demkow, Marcin; Miśko, Jolanta; Rużyłło, Witold

    2012-01-01

    Background: Previous studies have advocated quantifying pulmonary regurgitation (PR) by using PR volume (PRV) instead of commonly used PR fraction (PRF). However, physicians are not familiar with the use of PRV in clinical practice. The ratio of right ventricle (RV) volume to left ventricle volume (RV/LV) may better reflect the impact of PR on the heart than RV end-diastolic volume (RVEDV) alone. We aimed to compare the impact of PRV and PRF on RV size expressed as either the RV/LV ratio or RVEDV (mL/m 2 ). Methods: Consecutive patients with repaired tetralogy of Fallot were included (n = 53). PRV, PRF and ventricular volumes were measured with the use of cardiac magnetic resonance. Results: RVEDV was more closely correlated with PRV when compared with PRF (r = 0.686, p 2.0 [area under the curve (AUC) PRV = 0.770 vs AUC PRF = 0.777, p = 0.86]. Conversely, with the use of the RVEDV-based criterion (>170 mL/m 2 ), PRV proved to be superior over PRF (AUC PRV = 0.770 vs AUC PRF = 0.656, p = 0.0028]. Conclusions: PRV and PRF have similar significance as measures of PR when the RV/LV ratio is used instead of RVEDV. The RV/LV ratio is a universal marker of RV dilatation independent of the method of PR quantification applied (PRF vs PRV)

  3. Left ventricular remodeling and change of systolic function after closure of patent ductus arteriosus in adults: device and surgical closure.

    Science.gov (United States)

    Jeong, Young-Hoon; Yun, Tae-Jin; Song, Jong-Min; Park, Jung-Jun; Seo, Dong-Man; Koh, Jae-Kon; Lee, Se-Whan; Kim, Mi-Jeong; Kang, Duk-Hyun; Song, Jae-Kwan

    2007-09-01

    Left ventricular (LV) remodeling and predictors of LV systolic function late after closure of patent ductus arteriosus (PDA) in adults remain to be clearly demonstrated. In 45 patients with PDA, including 28 patients who received successful occlusion using the Amplatzer device (AD group) (AGA, Golden Valley, MN) and 17 patients who received surgical closure (OP group), echocardiography studies were performed before closure and 1 day (AD group) or within 7 days (OP group) after closure, and then were repeated at > or = 6 months (17 +/- 13 months). In both groups, LV ejection fraction (EF) and end-diastolic volume index were significantly decreased immediately after closure, whereas end-systolic volume index did not change. During the long-term follow-up period, end-systolic as well as end-diastolic volume indices decreased significantly in both groups and LV EF recovered compared to the immediate postclosure state. However, LV EF remained low compared to the preclosure state. Five patients (11.1%) including 3 patients in the AD group and 2 patients in the OP group showed persistent late LV systolic dysfunction (EF or = 62% had a sensitivity of 72% and a specificity of 83% for predicting late normal LV EF after closure. Left ventricular EF remains low late after PDA closure compared with preclosure state in adults. Preclosure LV EF is the best index to predict late postclosure LV EF.

  4. Early diastolic mitral annular velocity at the interventricular septal annulus correctly reflects left ventricular longitudinal myocardial relaxation.

    Science.gov (United States)

    Okada, Kazunori; Mikami, Taisei; Kaga, Sanae; Onozuka, Hisao; Inoue, Mamiko; Yokoyama, Shinobu; Nishino, Hisao; Nishida, Mutsumi; Matsuno, Kazuhiko; Iwano, Hiroyuki; Yamada, Satoshi; Tsutsui, Hiroyuki

    2011-12-01

    Early diastolic mitral annular velocity (e') obtained by tissue Doppler imaging (TDI) is widely used to evaluate left ventricular (LV) diastolic function based on the assumption that it reflects myocardial relaxation in the long-axis direction. In this study, we aimed to determine whether or not e' truly reflects early diastolic longitudinal myocardial relaxation, and which is the most useful for evaluating LV diastolic function among e' measured at the interventricular-septal annulus (IS-e'), that measured at the lateral annulus (LW-e') or their mean value (M-e'). IS-e', LW-e', and M-e' were measured using colour TDI in 15 patients with hypertrophic cardiomyopathy, 13 patients with hypertension, and 19 control subjects. Using two-dimensional speckle-tracking imaging, early diastolic myocardial strain rates (SR(E)) were measured for the IS (IS-SR(E)), LW (LW-SR(E)), and entire LV myocardium (G-SR(E)). IS-e' was excellently correlated with IS-SR(E) (r = 0.90, P < 0.001); the correlation was better than that between LW-e' and LW-SR(E) (r = 0.75, P < 0.001). IS-e' and M-e' were well correlated with G-SR(E) (r = 0.88, P < 0.001 and r = 0.86, P< 0.001, respectively) and with LV early diastolic flow propagation velocity (FPV) (r = 0.77, P < 0.001 and r = 0.78, P < 0.001, respectively). The correlations of LW-e' to G-SR(E) (r = 0.80, P < 0.001) and FPV (r = 0.75, P < 0.001) did not reach this level. IS-e' well reflected LV longitudinal myocardial relaxation and LV diastolic function, and was found to be more useful in evaluating LV diastolic function than LW-e'.

  5. Effects of upright and supine position on cardiac rest and exercise response in aortic regurgitation.

    Science.gov (United States)

    Shen, W F; Roubin, G S; Fletcher, P J; Choong, C Y; Hutton, B F; Harris, P J; Kelly, D T

    1985-02-01

    The effects of upright and supine position on cardiac response to exercise were assessed by radionuclide ventriculography in 15 patients with moderate to severe aortic regurgitation (AR) and in 10 control subjects. In patients with AR, heart rate was higher during upright exercise, but systolic and diastolic blood pressure and left ventricular (LV) output were similar during both forms of exercise. LV stroke volume and end-diastolic volume were not altered during supine exercise. LV end-systolic volume increased and ejection fraction decreased during supine exercise, but both were unchanged during upright exercise. Of 15 patients, 5 in the upright and 12 in the supine position had an abnormal LV ejection fraction response to exercise (p less than 0.01). Right ventricular ejection fraction increased and regurgitant index decreased with both forms of exercise and was not significantly different between the 2 positions. Thus, posture is important in determining LV response to exercise in patients with moderate to severe AR.

  6. Increased left ventricular mass and diastolic dysfunction are associated with endothelial dysfunction in normotensive offspring of subjects with essential hypertension.

    Science.gov (United States)

    Zizek, Bogomir; Poredos, Pavel

    2007-01-01

    We aimed to investigate left ventricular (LV) morphology and function in normotensive offspring of subjects with essential hypertension (familial trait - FT), and to determine the association between LV mass and determinants of LV diastolic function and endothelium-dependent (NO-mediated) dilation of the brachial artery (BA). The study encompassed 76 volunteers of whom 44 were normotonics with FT aged 28-39 (mean 33) years and 32 age-matched controls without FT. LV mass and LV diastolic function was measured using conventional echocardiography and tissue Doppler imaging (TDI). LV diastolic filling properties were assessed and reported as the peak E/A wave ratio, and peak septal annular velocities (E(m) and E(m)/A(m) ratio) on TDI. Using high-resolution ultrasound, BA diameters at rest and during reactive hyperaemia (flow-mediated dilation--FMD) were measured. In subjects with FT, the LV mass index was higher than in controls (92.14+/-24.02 vs 70.08+/-20.58); p<0.001). Offspring of hypertensive families had worse LV diastolic function than control subjects (lower E/A ratio, lower E(m) and E(m)/A(m) ratio; p<0.001). In subjects with FT, FMD was decreased compared with the controls (6.11+/-3.28% vs 10.20+/-2.07%; p<0.001). LV mass index and E(m)/A(m) ratio were associated with FMD (p<0.001). In normotensive individuals with FT, LV morphological and functional changes were found. We demonstrated that an increase in LV mass and alterations in LV diastolic function are related to endothelial dysfunction.

  7. Routine Chest X-ray: Still Valuable for the Assessment of Left Ventricular Size and Function in the Era of Super Machines?

    Science.gov (United States)

    Morales, Maria-Aurora; Prediletto, Renato; Rossi, Giuseppe; Catapano, Giosuè; Lombardi, Massimo; Rovai, Daniele

    2012-01-01

    The development of technologically advanced, expensive techniques has progressively reduced the value of chest X-ray in clinical practice for the assessment of left ventricular (LV) dilatation and dysfunction. Although controversial data are reported on the role of this widely available technique in cardiac assessment, it is known that the cardio-thoracic ratio is predictive of risk of progression in the NYHA Class, hospitalization, and outcome in patients with LV dysfunction. This study aimed to evaluate the reliability of the transverse diameter of heart shadow [TDH] by chest X-ray for detecting LV dilatation and dysfunction as compared to Magnetic Resonance Imaging (MRI) performed for different clinical reasons. In 101 patients, TDH was measured in digital chest X-ray and LV volumes and ejection fraction (EF) by MRI, both exams performed within 2 days. A direct correlation between TDH and end-diastolic volumes (r = .75, Pvalues of 14.5 mm in females identified LV end-diastolic volumes >150 mL (sensitivity: 82%, specificity: 69%); in males a cut-off value of 15.5 mm identified LV end-diastolic volumes >210 mL (sensitivity: 84%; specificity: 72%). A negative relation was found between TDH and LVEF (r = -.54, Pvalues of TDH discriminated patients with LV systolic dysfunction - LVEF <35% (sensitivity and specificity: 67% and 57% in females; 76% and 59% in males, respectively). Chest X-ray may still be considered a reliable technique in predicting LV dilatation by the accurate measurement of TDH as compared to cardiac MRI. Technologically advanced, expensive, and less available imaging techniques should be performed on the basis of sound clinical requests.

  8. Longitudinal changes and prognostic implications of left ventricular diastolic function in first acute myocardial infarction

    DEFF Research Database (Denmark)

    Poulsen, S H; Jensen, S E; Egstrup, K

    1999-01-01

    BACKGROUND: Left ventricular (LV) diastolic dysfunction contributes to signs and symptoms of clinical heart failure and may be related to prognosis in heart diseases. LV diastolic dysfunction is reported to be present in acute myocardial infarction (MI); however, little is known about the time...... demonstrated a significant LV dilation during 1-year follow-up. Patients with initial pseudonormal/restrictive LV filling pattern were more frequently readmitted to the hospital for heart failure and had significant higher New York Heart Association class score compared with patients with normal or impaired...

  9. Chymase inhibition prevents fibronectin and myofibrillar loss and improves cardiomyocyte function and LV torsion angle in dogs with isolated mitral regurgitation.

    Science.gov (United States)

    Pat, Betty; Chen, Yuanwen; Killingsworth, Cheryl; Gladden, James D; Shi, Ke; Zheng, Junying; Powell, Pamela C; Walcott, Greg; Ahmed, Mustafa I; Gupta, Himanshu; Desai, Ravi; Wei, Chih-Chang; Hase, Naoki; Kobayashi, Tsunefumi; Sabri, Abdelkarim; Granzier, Henk; Denney, Thomas; Tillson, Michael; Dillon, A Ray; Husain, Ahsan; Dell'italia, Louis J

    2010-10-12

    The left ventricular (LV) dilatation of isolated mitral regurgitation (MR) is associated with an increase in chymase and a decrease in interstitial collagen and extracellular matrix. In addition to profibrotic effects, chymase has significant antifibrotic actions because it activates matrix metalloproteinases and kallikrein and degrades fibronectin. Thus, we hypothesize that chymase inhibitor (CI) will attenuate extracellular matrix loss and LV remodeling in MR. We studied dogs with 4 months of untreated MR (MR; n=9) or MR treated with CI (MR+CI; n=8). Cine MRI demonstrated a >40% increase in LV end-diastolic volume in both groups, consistent with a failure of CI to improve a 25% decrease in interstitial collagen in MR. However, LV cardiomyocyte fractional shortening was decreased in MR versus normal dogs (3.71±0.24% versus 4.81±0.31%; P<0.05) and normalized in MR+CI dogs (4.85±0.44%). MRI with tissue tagging demonstrated an increase in LV torsion angle in MR+CI versus MR dogs. CI normalized the significant decrease in fibronectin and FAK phosphorylation and prevented cardiomyocyte myofibrillar degeneration in MR dogs. In addition, total titin and its stiffer isoform were increased in the LV epicardium and paralleled the changes in fibronectin and FAK phosphorylation in MR+CI dogs. These results suggest that chymase disrupts cell surface-fibronectin connections and FAK phosphorylation that can adversely affect cardiomyocyte myofibrillar structure and function. The greater effect of CI on epicardial versus endocardial titin and noncollagen cell surface proteins may be responsible for the increase in torsion angle in chronic MR.

  10. Percutaneous closure of patent ductus arteriosus in children: Immediate and short-term changes in left ventricular systolic and diastolic function

    OpenAIRE

    Gupta, Saurabh Kumar; Krishnamoorthy, KM; Tharakan, Jaganmohan A; Sivasankaran, S; Sanjay, G; Bijulal, S; Anees, T

    2011-01-01

    Objective: To evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) systolic and diastolic function in children. Background: Limited studies are available on alteration in LV hemodynamics, especially diastolic function, after PDA closure. Methods: Thirty-two consecutive children with isolated PDA treated by trans-catheter closure were studied. The LV systolic and diastolic function were assessed by two-dimensional (2D) echocardiography ...

  11. The ratio of right ventricular volume to left ventricular volume reflects the impact of pulmonary regurgitation independently of the method of pulmonary regurgitation quantification

    Energy Technology Data Exchange (ETDEWEB)

    Śpiewak, Mateusz, E-mail: mspiewak@ikard.pl [Department of Coronary Artery Disease and Structural Heart Diseases, Institute of Cardiology, Warsaw (Poland); Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Małek, Łukasz A., E-mail: lmalek@ikard.pl [Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Department of Interventional Cardiology and Angiology, Institute of Cardiology, Warsaw (Poland); Petryka, Joanna, E-mail: joannapetryka@hotmail.com [Department of Coronary Artery Disease and Structural Heart Diseases, Institute of Cardiology, Warsaw (Poland); Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Mazurkiewicz, Łukasz, E-mail: lmazurkiewicz@ikard.pl [Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Department of Cardiomyopathy, Institute of Cardiology, Warsaw (Poland); Miłosz, Barbara, E-mail: barbara-milosz@o2.pl [Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Department of Radiology, Institute of Cardiology, Warsaw (Poland); Biernacka, Elżbieta K., E-mail: kbiernacka@ikard.pl [Department of Congenital Heart Diseases, Institute of Cardiology, Warsaw (Poland); Kowalski, Mirosław, E-mail: mkowalski@ikard.pl [Department of Congenital Heart Diseases, Institute of Cardiology, Warsaw (Poland); Hoffman, Piotr, E-mail: phoffman@ikard.pl [Department of Congenital Heart Diseases, Institute of Cardiology, Warsaw (Poland); Demkow, Marcin, E-mail: mdemkow@ikard.pl [Department of Coronary Artery Disease and Structural Heart Diseases, Institute of Cardiology, Warsaw (Poland); Miśko, Jolanta, E-mail: jmisko@wp.pl [Cardiac Magnetic Resonance Unit, Institute of Cardiology, Warsaw (Poland); Department of Radiology, Institute of Cardiology, Warsaw (Poland); Rużyłło, Witold, E-mail: wruzyllo@ikard.pl [Institute of Cardiology, Warsaw (Poland)

    2012-10-15

    Background: Previous studies have advocated quantifying pulmonary regurgitation (PR) by using PR volume (PRV) instead of commonly used PR fraction (PRF). However, physicians are not familiar with the use of PRV in clinical practice. The ratio of right ventricle (RV) volume to left ventricle volume (RV/LV) may better reflect the impact of PR on the heart than RV end-diastolic volume (RVEDV) alone. We aimed to compare the impact of PRV and PRF on RV size expressed as either the RV/LV ratio or RVEDV (mL/m{sup 2}). Methods: Consecutive patients with repaired tetralogy of Fallot were included (n = 53). PRV, PRF and ventricular volumes were measured with the use of cardiac magnetic resonance. Results: RVEDV was more closely correlated with PRV when compared with PRF (r = 0.686, p < 0.0001, and r = 0.430, p = 0.0014, respectively). On the other hand, both PRV and PRF showed a good correlation with the RV/LV ratio (r = 0.691, p < 0.0001, and r = 0.685, p < 0.0001, respectively). Receiver operating characteristic analysis showed that both measures of PR had similar ability to predict severe RV dilatation when the RV/LV ratio-based criterion was used, namely the RV/LV ratio > 2.0 [area under the curve (AUC){sub PRV} = 0.770 vs AUC{sub PRF} = 0.777, p = 0.86]. Conversely, with the use of the RVEDV-based criterion (>170 mL/m{sup 2}), PRV proved to be superior over PRF (AUC{sub PRV} = 0.770 vs AUC{sub PRF} = 0.656, p = 0.0028]. Conclusions: PRV and PRF have similar significance as measures of PR when the RV/LV ratio is used instead of RVEDV. The RV/LV ratio is a universal marker of RV dilatation independent of the method of PR quantification applied (PRF vs PRV)

  12. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    Directory of Open Access Journals (Sweden)

    Jonny Nordström

    2017-11-01

    Full Text Available Abstract Background Quantitative measurement of myocardial blood flow (MBF is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD. 15O-water positron emission tomography (PET is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV volumes and ejection fraction (EF is not possible from standard 15O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B 15O-water images and from first pass (FP images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV, end-diastolic volume (EDV, stroke volume (SV and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Results Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p < 0.001. Conclusion Calculation of LV volumes and LVEF from dynamic 15O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  13. PECULIARITIES OF PARAMETERS OF ECHOCARDIOGRAPHY IN PATIENTS WITH ACUTE CORONARY SYNDROMES WITH COMORBID ANXIETY AND DEPRESSIVE DISORDERS

    Directory of Open Access Journals (Sweden)

    N. Yu. Shimohina

    2014-01-01

    Full Text Available This study has assessed the functional parameters of the cardiovascular system by echocardiography in patients with acute coronary syndrome (ACS in combination with anxiety and depressive disorders (ADD. Were examined 152 patients in the first 24 hours after the onset of ACS. All patients in the first 48 hours after hospitalization was performed transthoracic echocardiography (EchoCG on the apparatus Vivid E9 (General Electric, USA. These echocardiographic indices were analyzed: stroke volume (SV of left ventricular (LV, minute volume of heart (MVH, ejection fraction (EF, determined by the method Teicholz, end-systolic volume (ESV, end-diastolic volume (EDV, thickness of interventricular septum in diastole (TISD, thickness of posterior wall the LV in diastole (TPWLD, anteroposterior size of the left atrium (LA. Local contractility of LV assessed by the presence of hypo- or akinesia and dyskinesia zones. Diastolic function of LV was assessed by transmitral blood Dopplerograms, noted the presence of valvular cardiac pathology. In the first 72 hours after being transferred from emergency rooms all patients were tested of test of Spielberg–Hanin, Hospital Anxiety and Depression Scale, Beck questionnaire and depression scale epidemiological studies Center USA for determine the presence or not ADD.A result of study patients with ACS in conjunction with ADD have significant excess volume indices of LV in comparison with patients without ADD, in addition, this group have an increase in the size of the LA, MVH and left ventricular has hypertrophy in terms TISD comparison with the group. According to data EchoCG in patients with ACS and ADD very often visualized local contractility disturbances LV, zone of dyskinesia and defeat sclerotic of the aortic and mitral valves and diastolic dysfunction of LV in the type “slow relaxation” in comparison with patients with ACS without ADD.In patients with ACS concomitant ADD has a negative effect on the

  14. Cardiac resynchronization induces major structural and functional reverse remodeling in patients with New York Heart Association class I/II heart failure

    DEFF Research Database (Denmark)

    St John Sutton, Martin; Ghio, Stefano; Plappert, Ted

    2009-01-01

    BACKGROUND: Cardiac resynchronization therapy (CRT) improves LV structure, function, and clinical outcomes in New York Heart Association class III/IV heart failure with prolonged QRS. It is not known whether patients with New York Heart Association class I/II systolic heart failure exhibit left...... ventricular (LV) reverse remodeling with CRT or whether reverse remodeling is modified by the cause of heart failure. METHODS AND RESULTS: Six hundred ten patients with New York Heart Association class I/II heart failure, QRS duration > or =120 ms, LV end-diastolic dimension > or =55 mm, and LV ejection...... reduction in LV end-diastolic and end-systolic volume indexes and a 3-fold greater increase in LV ejection fraction in patients with nonischemic causes of heart failure. CONCLUSIONS: CRT in patients with New York Heart Association I/II resulted in major structural and functional reverse remodeling at 1 year...

  15. Effect of Mitral Annular Calcium on Left Ventricular Diastolic Parameters.

    Science.gov (United States)

    Codolosa, Jose N; Koshkelashvili, Nikoloz; Alnabelsi, Talal; Goykhman, Igor; Romero-Corral, Abel; Pressman, Gregg S

    2016-03-01

    Assessment of left ventricular (LV) diastolic function by Doppler flow imaging and tissue Doppler is an integral part of the echocardiographic examination. Mitral annular calcium (MAC) is frequently encountered on echocardiography. The aim of this study was to assess the impact of MAC, quantitatively measured by computed tomography scan, on echocardiographic LV diastolic parameters. We included 155 patients aged ≥65 years. Computed tomography reconstructions of the mitral annulus were created, and calcium identified and quantified by Agatston technique. Calcium locations were assigned using an overlaid template depicting the annular segments in relation to surrounding anatomic structures. Echocardiographic assessment of diastolic function was performed in standard fashion. Mean age was 77 years; 49% were men; and 43% were black. Patients with MAC had lower septal e' (p = 0.003), lateral e' (p = 0.04), and average e' (p = 0.01) compared with those without MAC. They also had a higher E-wave velocity (p = 0.01) and E/e' ratio (p <0.001). When evaluated by severity of MAC, and after adjustment for multiple clinical factors, there was a graded (inverse) relation between MAC severity and septal e' (p = 0.01), lateral e' (p = 0.01), and average e' (p = 0.01). In conclusion, LV diastolic parameters, as measured by Doppler echocardiography, are altered in the presence of MAC. This could be due to direct effects of MAC on annular function or might reflect truly reduced diastolic function. Interpretation of diastolic parameters in patients with MAC should be performed with caution. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. The influence of percutaneous closure of patent ductus arteriosus on left ventricular size and function: a prospective study using two- and three-dimensional echocardiography and measurements of serum natriuretic peptides.

    Science.gov (United States)

    Eerola, Anneli; Jokinen, Eero; Boldt, Talvikki; Pihkala, Jaana

    2006-03-07

    We aimed to evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) hemodynamics. Today, most PDAs are closed percutaneously. Little is known, however, about hemodynamic changes after the procedure. Of 37 children (ages 0.6 to 10.6 years) taken to the catheterization laboratory for percutaneous PDA closure, the PDA was closed in 33. Left ventricular diastolic and systolic dimensions, volumes, and function were examined by two-dimensional (2D) and three-dimensional (3D) echocardiography and serum concentrations of natriuretic peptides measured before PDA closure, on the following day, and 6 months thereafter. Control subjects comprised 36 healthy children of comparable ages. At baseline, LV diastolic diameter measured >+2 SD in 5 of 33 patients. In 3D echocardiography, a median LV diastolic volume measured 54.0 ml/m2 in the control subjects and 58.4 ml/m2 (p closure and 57.2 ml/m2 (p = NS) 6 months after closure. A median N-terminal brain natriuretic peptide (pro-BNP) concentration measured 72 ng/l in the control group and 141 ng/l in the PDA group before closure (p = 0.001) and 78.5 ng/l (p = NS) 6 months after closure. Patients differed from control subjects in indices of LV systolic and diastolic function at baseline. By the end of follow-up, all these differences had disappeared. Even in the subgroup of patients with normal-sized LV at baseline, the LV diastolic volume decreased significantly during follow-up. Changes in LV volume and function caused by PDA disappear by 6 months after percutaneous closure. Even the children with normal-sized LV benefit from the procedure.

  17. A high-sugar and high-fat diet impairs cardiac systolic and diastolic function in mice.

    Science.gov (United States)

    Carbone, Salvatore; Mauro, Adolfo G; Mezzaroma, Eleonora; Kraskauskas, Donatas; Marchetti, Carlo; Buzzetti, Raffaella; Van Tassell, Benjamin W; Abbate, Antonio; Toldo, Stefano

    2015-11-01

    Heart failure (HF) is a clinical syndrome characterized by dyspnea, fatigue, exercise intolerance and cardiac dysfunction. Unhealthy diet has been associated with increased risk of obesity and heart disease, but whether it directly affects cardiac function, and promotes the development and progression of HF is unknown. We fed 8-week old male or female CD-1 mice with a standard diet (SD) or a diet rich in saturated fat and sugar, resembling a "Western" diet (WD). Cardiac systolic and diastolic function was measured at baseline and 4 and 8 weeks by Doppler echocardiography, and left ventricular (LV) end-diastolic pressure (EDP) by cardiac catheterization prior to sacrifice. An additional group of mice received WD for 4 weeks followed by SD (wash-out) for 8 weeks. WD-fed mice experienced a significant decreased in LV ejection fraction (LVEF), reflecting impaired systolic function, and a significant increase in isovolumetric relaxation time (IRT), myocardial performance index (MPI), and LVEDP, showing impaired diastolic function, without any sex-related differences. Switching to a SD after 4 weeks of WD partially reversed the cardiac systolic and diastolic dysfunction. A diet rich in saturated fat and sugars (WD) impairs cardiac systolic and diastolic function in the mouse. Further studies are required to define the mechanism through which diet affects cardiac function, and whether dietary interventions can be used in patients with, or at risk for, HF. Published by Elsevier Ireland Ltd.

  18. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

    Science.gov (United States)

    Qin, J. J.; Jones, M.; Shiota, T.; Greenberg, N. L.; Firstenberg, M. S.; Tsujino, H.; Zetts, A. D.; Sun, J. P.; Cardon, L. A.; Odabashian, J. A.; hide

    2000-01-01

    AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, Pmethods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

  19. Extent of late gadolinium enhancement at right ventricular insertion points in patients with hypertrophic cardiomyopathy: relation with diastolic dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yinsu [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); The First Affiliated Hospital of Nanjing Medical University, Department of Radiology, Nanjing, Jiangsu (China); Park, Eun-Ah; Lee, Whal; Chu, Ajung; Chung, Jin Wook; Park, Jae Hyung [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Kim, Hyung-Kwan [Seoul National University Hospital, Division of Cardiology, Department of Internal Medicine, Seoul (Korea, Republic of)

    2015-04-01

    Our aim was to examine the association between the extent of late gadolinium enhancement (LGE) at right ventricular insertion points (RVIP) and left ventricular (LV) functional parameters in patients with hypertrophic cardiomyopathy (HCM). Sixty-one HCM patients underwent echocardiography and cardiovascular magnetic resonance (CMR) within one week. Mitral annular velocities (E/E') were obtained from echocardiography; LV ejection fraction (EF), LV mass index, LV wall maximal thickness, and left atrial volume index (LAVI) were obtained from MR. LGE extent was quantified (proportion of total LV myocardial mass) according to location: % RVIP-LGE and % non-RVIP-LGE. Although LGE was commonly present in both apical (74 %) and non-apical HCMs (88 %) (p = 0.163), RVIP-LGE was more frequent (86 % vs. 47 %, p = 0.002) in non-apical HCMs in which E/E' was significantly higher (19.23 ± 8.40 vs. 13.13 ± 5.06, p = 0.009). In addition, RVIP-LGE extent was associated with LV diastolic dysfunction (r = 0.45, p < 0.001 for E/E'; r = 0.53, p < 0.001 for LAVI) and lower LVEF (r = -0.42, p = 0.001). There was no correlation between non-RVIP-LGE extent and other parameters. Multiple linear regression analysis revealed RVIP-LGE extent as an independent predictor of E/E' (β = 0.45, p < 0.001) and LAVI in HCM patients (β = 0.53, p < 0.001). The extent of LGE at RVIPs in HCM patients is associated with increased estimated LV filling pressure and chronic diastolic burden. (orig.)

  20. Altered Aortic Upper Wall TDI Velocity Is Inversely Related with Left Ventricular Diastolic Function in Operated Tetralogy of Fallot.

    Science.gov (United States)

    Bassareo, Pier Paolo; Saba, Luca; Marras, Andrea R; Mercuro, Giuseppe

    2016-12-01

    Postoperative tetralogy of Fallot (TOF) patients often develop progressive aortic root dilatation due to an impairment in aortic elastic properties. (1) to assess aortic elasticity at the level of the aortic upper wall by tissue Doppler imaging (TDI); (2) to evaluate the influence of aortic elasticity on left ventricular (LV) diastolic function in TOF patients. Twenty-eight postoperative TOF patients (14 males, 14 females. Mean age: 25.7 ± 1.6 years) and 28 age- and sex-matched normal subjects were examined. Aortic distensibility and stiffness index were calculated. Aortic wall systolic and diastolic velocities, LV systolic and diastolic parameters were assessed by TDI. Aortic distensibility was significantly lower (P = .024), and aortic stiffness index significantly higher (P = .036) in TOF patients compared to controls. E/E' was significantly higher in TOF than in control group (P < .001). Aortic upper wall early diastolic velocity (AWEDV) was significantly correlated with aortic stiffness index (r: -0.42; P < .03), aortic distensibility (r = 0.54; P < .004), left atrial volume (r = -0.62; P = .0004), and E/E' ratio (r = -0.87; P < .0001). The latter relationship remained significant even when excluding the influence of age at surgery (r = -0.60; P < .0007) and of previous palliative surgery (r = -0.53; P < .02). Aortic elastic properties can be directly assessed using TDI to measure AWEDV. Aortic elasticity is significantly lower in postoperative TOF patients, exerting a negative effect also on LV diastolic function, with a potential long-term influence on clinical status. © 2016 Wiley Periodicals, Inc.

  1. Association diastolic function by echo and infarct size by magnetic resonance imaging after STEMI

    DEFF Research Database (Denmark)

    Søholm, Helle; Lønborg, Jacob; Andersen, Mads J

    2016-01-01

    OBJECTIVES: Left ventricular (LV) diastolic dysfunction is a predictor of increased morbidity and mortality; however, little is known about diastolic function and the degree of myocardial damage after myocardial infarction (MI). The aim was to assess the association between diastolic dysfunction ...

  2. Acceleration rate of mitral inflow E wave: a novel transmitral doppler index for assessing diastolic function.

    Science.gov (United States)

    Badkoubeh, Roya Sattarzadeh; Tavoosi, Anahita; Jabbari, Mostafa; Parsa, Amir Farhang Zand; Geraeli, Babak; Saadat, Mohammad; Larti, Farnoosh; Meysamie, Ali Pasha; Salehi, Mehrdad

    2016-06-10

    We performed comprehensive transmitral and pulmonary venous Doppler echocardiographic studies to devise a novel index of diastolic function. This is the first study to assess the utility of the acceleration rate (AR) of the E wave of mitral inflow as a primary diagnostic modality for assessing diastolic function. Study group consisted of 84 patients (53 + 11 years) with left ventricle (LV) diastolic dysfunction and 34 healthy people (35 ± 9 years) as control group, who were referred for clinically indicated two-dimensional transthoracic echocardiogram (TTE) during 2012 and 2013 to Imam Hospital. Normal controls were defined as patients without clinical evidence of cardiac disease and had normal TTE. LV diastolic function was determined according to standardized protocol of American Society of Echocardiography (ASE). As our new parameter, AR of E wave of mitral inflow was also measured in all patients. It was represented by the slope of the line between onset of E wave and peak of it. Correlation between AR of E wave and LV diastolic function grade was measured using the Spearman correlation coefficient. Receiver operating characteristic (ROC) curve was used to determine the sensitivity and specificity of AR of E wave in diagnosing LV diastolic dysfunction in randomly selected two-thirds of population then its derived cutoff was evaluated in rest of the population. The institutional review board of the hospital approved the study protocol. All participants gave written informed consent. This investigation was in accordance with the Declaration of Helsinki. The mean value of AR was 1010 ± 420 cm/s(2) in patients whereas the mean value for the normal controls was 701 ± 210 cm/s(2). There was a strong and graded relation between AR of E wave of mitral inflow and LV diastolic function grade (Spearman P ≤0.0001, rs =0.69). ROC curve analysis revealed that AR of E wave of mitral inflow =750 cm/s(2) predicted moderate or severe LV diastolic

  3. Evaluation of diastolic phase by left ventricular volume curve using s2-gated equilibrium method among radioisotope angiography

    International Nuclear Information System (INIS)

    Watanabe, Yoshirou; Sakai, Akira; Inada, Mitsuo; Shiraishi, Tomokuni; Kobayashi, Akitoshi

    1982-01-01

    S2-gated (the second heart sound) method was designed by authors. In 6 normal subjects and 16 patients (old myocardial infarction 12 cases, hypertension 2 cases and aortic regurgitation 2 cases), radioisotope (RI) angiography using S2-gated equilibrium method was performed. In RI angiography, sup(99m)Tc-human serum albumin (HSA) 555MBq (15mCi) as tracer, PDP11/34 as minicomputer and PCG/ECG symchromizer (Metro Inst.) were used. Then left ventricular (LV) volume curve by S2-gated and electrocardiogram (ECG) R wave-gated method were obtained. Using LV volume curve, left ventricular ejection fraction (EF), mean ejection rate (mER, s -1 ), mean filling rate (mFR, -1 ) and rapid filling fraction (RFF) were calculated. mFR indicated mean filling rate during rapid filling phase. RFF was defined as the filling fraction during rapid filling phase among stroke volume. S2-gated method was reliable in evaluation of early diastolic phase, compared with ECG-gated method. There was the difference between RFF in normal group and myocardial infarction (MI) group (p < 0.005). RFF in 2 groups were correlated with EF (r = 0.82, p < 0.01). RFF was useful in evaluating MI cases who had normal EF values. The comparison with mER by ECG-gated and mFR by S2-gated was useful in evaluating MI cases who had normal mER values. mFR was remarkably lower than mER in MI group, but was equal to mER in normal group approximately. In conclusion, the evaluation using RFF and mFR by S2-gated method was useful in MI cases who had normal systolic phase indices. (author)

  4. Diastolic And Systolic Right Ventricular Dysfunction Precedes Left Ventricular Dysfunction In Patients Paced From Right Ventricular Apex

    Directory of Open Access Journals (Sweden)

    Dwivedi SK

    2006-07-01

    Full Text Available Background: Cardiac dysfunction after right ventricular (RV apical pacing is well known but its extent, time frame of appearance and individual effect on left ventricular (LV, RV systolic and diastolic parameters has not evaluated in a systematic fashion. Methods: Patients with symptomatic bradycardia and ACC-AHA Class I indication for permanent pacemaker implantation (PPI were implanted a single chamber (VVI pacemaker. They were followed prospectively by echocardiographic examination which was done at baseline, 1 week, 1 month and 6 months after implantation. Parameters observed were chamber dimensions (M-line, chamber volumes, cardiac output (modified Simpson's method, systolic functions (ejection fraction, pre-ejection period, ejection time and ratio and diastolic functions( isovolumic relaxation time & deceleration time of left and right heart. Results: Forty eight consecutive patients (mean age 65.6±11.8 yrs, 66.7% males, mean EF 61.82±10.36% implanted a VVI pacemaker were enrolled in this study. The first significant change to appear in cardiac function after VVI pacing was in diastolic properties of RV as shown by increase in RV isovolumic relaxation time (IVRT from 65.89±15.93 to 76.58±17.00 ms,(p<0.001 at 1week and RV deceleration time (DT from 133.84±38.13 to 153.09±31.41 ms, (p=0.02 at 1 month. Increase in RV internal dimension (RVID from 1.26±0.41 to 1.44±0.44, (p<0.05 was also noticed at 1 week. The LV diastolic parameters were significantly altered after 1 month with increase in LV-IVRT from 92.36±21.47 to 117.24±27.21ms, (p<0.001 and increase in LV DT from 147.56±31.84 to 189.27±28.49ms,(p<0.01. This was followed by LV systolic abnormality which appeared at 6 months with an increase in LVPEP from 100.33±14.43 to 118.41±21.34ms, (p<0.001 and increase in LVPEP/LVET ratio from 0.34±0.46 to 0.44±0.10, (p<0.001]. The reduction in LV EF was manifested at 6 months falling from 61.82±10.36% to52.52±12.11%, (p<0

  5. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET.

    Science.gov (United States)

    Nordström, Jonny; Kero, Tanja; Harms, Hendrik Johannes; Widström, Charles; Flachskampf, Frank A; Sörensen, Jens; Lubberink, Mark

    2017-11-14

    Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15 O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard 15 O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B ) 15 O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15 O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p dynamic 15 O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  6. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    International Nuclear Information System (INIS)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi

    1991-01-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner [PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01]. Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR [T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01]. However, T-PER/RR and T-PFR/RR values were rather constant (20.9±3.2%, 17.0±2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high [r= 0.91 p<0.001]. To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author)

  7. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    Energy Technology Data Exchange (ETDEWEB)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi (Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine)

    1991-05-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner (PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01). Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR (T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01). However, T-PER/RR and T-PFR/RR values were rather constant (20.9+-3.2%, 17.0+-2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high (r= 0.91 p<0.001). To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author).

  8. The influence of right ventricular apical pacing on left atrial volume in patients with normal left ventricular function

    Directory of Open Access Journals (Sweden)

    AR Moaref1

    2008-03-01

    Full Text Available Background: Right ventricular apical (RVA pacing has been reported to induce several deleterious effects particularly in the presence of structural heart disease but can also involve patients with normal left ventricular (LV function. Left atrial (LA enlargement is one of these effects, but the majority of studies have measured LA dimension rather than volume.Objective: The present prospective study was designed to assess the effect of RVA pacing on LA volume in patients with normal LV function.Patients and Methods: The study comprised 41 consecutive patients with LV ejection fraction ≥ 45% and LV end diastolic dimension ≤ 56 mm who underwent single-or dual- chamber pacemaker implantation in RVA and followed for LA volume measurement and pacemaker analysis at least during the ensuing 4.2 months. Results: In all, 21 patients were excluded from the study due to five spontaneous wide QRS complex (≥120msec, one recent acute coronary syndrome,one significant valvular heart disease, three pacing frequency <90%, eight death or losing follow up in three cases. In remaining 20 patients, LA volume ragned from 21 to 54 mm3 with mean of 37.3±9.7 mm3 prior to pacemaker implantation that increased to 31 to 103 mm3 (54.3±17.0 during follow-up (P<0.001.Conclusion: RVA pacing might lead to an increase in LA volume even in patients with normal LV function.

  9. Correlation between late gadolinium enhancement and diastolic function in hypertrophic cardiomyopathy assessed by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Motoyasu, Munenobu; Kurita, Tairo; Onishi, Katsuya

    2008-01-01

    Diastolic dysfunction is common in patients with overt hypertrophic cardiomyopathy (HCM). Steady-state cine magnetic resonance imaging (MRI) enables measurement of the diastolic function of the left ventricle (LV), and late gadolinium enhanced MRI can delineate the presence and extent of fibrosis in HCM. The purpose of this study was to determine the relationship between the extent of myocardial fibrosis demonstrated by late gadolinium-enhanced MRI and diastolic dysfunction. Seventeen patients (13 men, mean age 57.7±9.8 years) with HCM were studied. The severity index of late gadolinium enhancement was determined by scoring the extent of enhanced tissue in 30 myocardial segments. The peak filling rate (PFR), LV ejection fraction and LV mass were determined by cine MRI. Contrast-enhanced MRI demonstrated late gadolinium enhancement in 97 of 510 segments (19%) and 13 of the 17 patients (77%). The severity index of late gadolinium enhancement demonstrated a significant negative correlation with PFR (r=-0.86, p<0.01) and with the LV ejection fraction (r=-0.59, p<0.05). No significant correlation was observed between the severity index of late gadolinium enhancement and LV mass (r=0.23, p=0.30). The extent of myocardial fibrosis revealed by late gadolinium-enhanced MRI has a strong relationship to diastolic dysfunction in patients with HCM. (author)

  10. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Ali, M.; Abid, A.R.; Rehman, T.A.; Masood, A.; Sohail, S.

    2010-01-01

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By applying 2 X 2 table sensitivity was 77.7%, specificity was 80

  11. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M; Abid, A R; Rehman, T A; Masood, A; Sohail, S [Allama Iqbal Medical College/Jinnah Hospital, Lahore(Pakistan)

    2010-10-15

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E < 10 was observed in 31 (51.7%), 11 - 15 in 20 (33.3%) and > 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By

  12. Assessment of early diastolic intraventricular pressure gradient in the left ventricle among patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Kobayashi, Maki; Takahashi, Ken; Yamada, Mariko; Yazaki, Kana; Matsui, Kotoko; Tanaka, Noboru; Shigemitsu, Sachie; Akimoto, Katsumi; Kishiro, Masahiko; Nakanishi, Keisuke; Kawasaki, Shiori; Nii, Masaki; Itatani, Keiichi; Shimizu, Toshiaki

    2017-11-01

    Assessment of left ventricular (LV) dysfunction is vital in patients with repaired tetralogy of Fallot (rTOF). The early diastolic intraventricular pressure gradient (IVPG) in the LV plays an important role in diastolic function. IVPG is calculated as the intraventricular pressure difference divided by the LV length, which allows to account for differences in LV size and therefore calculate IVPG in children. We aimed to investigate the mechanisms of LV diastolic dysfunction by measuring mid-to-apical IVPG as an indicator of the active suction force sucking blood from the left atrium into the LV. We included 38 rTOF patients and 101 healthy controls. The study population was stratified based on age group into children (4-9 years), adolescents (10-15 years), and adults (16-40 years). IVPGs were calculated based on mitral inflow measurements obtained using color M-mode Doppler echocardiography. Although total IVPGs did not differ between rTOF patients and controls, mid-to-apical IVPGs in adolescents and adults were smaller among rTOF patients than among controls (0.15 ± 0.05 vs. 0.21 ± 0.06 mmHg/cm, p < 0.05; 0.09 ± 0.07 vs. 0.17 ± 0.05 mmHg/cm, p < 0.001; respectively). Additionally, only mid-to-apical IVPG correlated linearly with peak circumferential strain (ρ = 0.217, p = 0.011), longitudinal strain (ρ = -0.231, p = 0.006), torsion (ρ = -0.200, p = 0.018), and untwisting rate in early diastole (ρ = -0.233, p = 0.006). In rTOF, the mechanisms underlying diastolic dysfunction involve reduced active suction force, which correlates with reduced LV deformation in all directions.

  13. A newly developed maneuver, field change conversion (FCC), improved evaluation of the left ventricular volume more accurately on quantitative gated SPECT (QGS) analysis

    International Nuclear Information System (INIS)

    Tajima, Osamu; Shibasaki, Masaki; Hoshi, Toshiko; Imai, Kamon

    2002-01-01

    The purpose of this study was to investigate whether a newly developed maneuver that reduces the reconstruction area by a half more accurately evaluates left ventricular (LV) volume on quantitative gated SPECT (QGS) analysis. The subjects were 38 patients who underwent left ventricular angiography (LVG) followed by G-SPECT within 2 weeks. Acquisition was performed with a general purpose collimator and a 64 x 64 matrix. On QGS analysis, the field magnification was 34 cm in original image (Original: ORI), and furthermore it was changed from 34 cm to 17 cm to enlarge the re-constructed image (Field Change Conversion: FCC). End-diastolic volume (EDV) and end-systolic volume (ESV) of the left ventricle were also obtained using LVG. EDV was 71±19 ml, 83±20 ml and 98±23 ml for ORI, FCC and LVG, respectively (p<0.001: ORI versus LVG, p<0.001: ORI versus FCC, p<0.001: FCC versus LVG). ESV was 28±12 ml, 34±13 ml and 41±14 ml for ORI, FCC and LVG, respectively (p<0.001: ORI versus LVG, p<0.001: ORI versus FCC, p<0.001: FCC versus LVG). FCC was better than ORI for calculating LV volume in clinical cases. Furthermore, FCC is a useful method for accurately measuring the LV volume on QGS analysis. (author)

  14. Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold.

    Science.gov (United States)

    Kido, Tomoyuki; Kido, Teruhito; Nakamura, Masashi; Watanabe, Kouki; Schmidt, Michaela; Forman, Christoph; Mochizuki, Teruhito

    2016-08-24

    Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard cine CMR. This prospective study aimed to evaluate the diagnostic quality and accuracy of single-breath-hold full cardiac cycle CS cine CMR, acquired over two heart beats, to quantify LV volume in comparison to multi-breath-hold standard cine CMR. Eighty-one participants underwent standard segmented breath-hold cine and CS real-time cine CMR examinations to obtain a stack of eight contiguous short-axis images with same high spatial (1.7 × 1.7 mm(2)) and temporal resolution (41 ms). Two radiologists independently performed qualitative analysis of image quality (score, 1 [i.e., "nondiagnostic"] to 5 [i.e., "excellent"]) and quantitative analysis of the LV volume measurements. The total examination time was 113 ± 7 s for standard cine CMR and 24 ± 4 s for CS cine CMR (p cine image quality was slightly lower than standard cine (4.8 ± 0.5 for standard vs. 4.4 ± 0.5 for CS; p cine were above 4 (i.e., good). No significant differences existed between standard and CS cine MR for all quantitative LV measurements. The mean differences with 95 % confidence interval (CI), based on Bland-Altman analysis, were 1.3 mL (95 % CI, -14.6 - 17.2) for LV end-diastolic volume, 0.2 mL (95 % CI, -9.8 to10.3) for LV end-systolic volume, 1.1 mL (95 % CI, -10.5 to 12.7) for LV stroke volume, 1.0 g (95 % CI, -11.2 to 13.3) for LV mass, and 0.4 % (95 % CI, -4.8 - 5.6) for LV ejection fraction. The interobserver and intraobserver variability for CS cine MR ranged from -4.8 - 1.6 % and from -7.3 - 9.3 %, respectively, with slopes of the regressions ranging 0.88-1.0 and 0

  15. Effects of Propranolol on the Left Ventricular Volume of Normal Subjects During CT Coronary Angiography

    International Nuclear Information System (INIS)

    Mo, Yuan Heng; Jaw, Fu Shan; Wang, Yung Cheng; Jeng, Chin Ming; Peng, Shinn Forng

    2011-01-01

    The purpose of this study is to determine the effects of propranolol on the left ventricular (LV) volume during CT coronary angiography. The LV volume of 252 normal Chinese subjects (126 subjects with propranolol medication and 126 age- and gender-matched Chinese subjects without medication) was estimated using 64 slices multi-detector CT (MDCT). The heart rate difference was analyzed by the logistic linear regression model with variables that included gender, age, body height, body weight, systolic blood pressure (SBP), diastolic blood pressure (DBP) and the dosage of propranolol. The following global LV functional parameters were calculated: the real-end diastolic volume (EDV), the real-end systolic volume (ESV) and the real-ejection fraction (EF). The female subjects had a greater decrease of heart rate after taking propranolol. The difference of heart rate was negatively correlated with the dosage of propranolol. The real-EDV, the real-ESV and the real-EF ranged from 48.1 to 109 mL/m2, 6.1 to 57.1 mL/m2 and 41% to 88%, respectively. There was no significant difference in the SBP and DBP between the groups without and with propranolol medication (123 ± 17 and 80 ± 10 mmHg; 120 ± 14 and 80 ± 11 mmHg, respectively). The real-EDV showed no significant difference between these two groups, but the real-ESV and real-EF showed significant differences between these two groups (69.4 ± 9.3 and 70.6 ± 8.9 mL/m2; 23.5 ± 5.7 and 25.6 ± 3.7 mL/m2, 66.5 ± 5.1% and 63.5 ± 4.6%, respectively). The difference of heart rate is significantly influenced by gender and the dosage of propranolol. Propranolol will also increase the ESV, which contributes to a decreased EF, while the SBP, DBP and EDV are not statistically changed.

  16. Evaluation of left ventricular volume by MRI using modified Simpson's rule method

    International Nuclear Information System (INIS)

    Okamura, Masahiro; Kondo, Takeshi; Anno, Naoko

    1990-01-01

    The conventional contrast left ventriculogrpahy (LVG) has been the gold standard for estimating left ventricular volume (LVV), but it is an invasive technique, and volume overload must be caused by contrast medium. the true left ventricular (LV) long axis may not be obtained by LVG in routine right anterior oblique (RAO) projection. MRI, on the other hand, is noninvasive, does not require contrast medium, and permits to obtain the true LV long axis sections. Thus, MRI seems the ideal technique for estimating LVV. To estimate LVV, we have developed the on-line programs for calculating LVV by single-plane (SMS) or biplane modified Simpson's rule method (BMS), and have applied these programs to the water in the bottle with the elliptic short axis plane, normal volunteer and patients with various heart diseases. In the water phantom, the water volume calculated by the BMS was more accurate than the SMS. In nine normal volunteers, multiple LV short axis sections in each end-systole and end-diastole were obtained by ECG-gated spin echo MRI, LVV as standard was calculated by true Simpson's rule method (TS) on these images. Then both vertical and horizontal LV long axis sections were also obtained by ECG-gated field echo (FE) rephasing cine MRI, LVV was calculated by the BMS or SMS on these images. The BMS or SMS significantly correlated (r=0.974, r=0.927, 0.947) with TS for estimating LVV, respectively. In 20 patients with various heart diseases, both vertical and horizontal LV long axis sections were obtained by FE cine MRI. LVV (r=0.907 and r=0.901) and EF (r=0.822 and r=0.938) calculated by the SMS on the vertical or horizontal LV long axis sections significantly correlated with the conventional RAO-LVG, respectively. In conclusion, the MRI using our on-line programs would be clinically useful for estimating LVV and EF. (author)

  17. Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study

    Directory of Open Access Journals (Sweden)

    Allansdotter-Johnsson Ase

    2009-01-01

    Full Text Available Abstract Background Knowledge about age-specific normal values for left ventricular mass (LVM, end-diastolic volume (EDV, end-systolic volume (ESV, stroke volume (SV and ejection fraction (EF by cardiac magnetic resonance imaging (CMR is of importance to differentiate between health and disease and to assess the severity of disease. The aims of the study were to determine age and gender specific normal reference values and to explore the normal physiological variation of these parameters from adolescence to late adulthood, in a cross sectional study. Methods Gradient echo CMR was performed at 1.5 T in 96 healthy volunteers (11–81 years, 50 male. Gender-specific analysis of parameters was undertaken in both absolute values and adjusted for body surface area (BSA. Results Age and gender specific normal ranges for LV volumes, mass and function are presented from the second through the eighth decade of life. LVM, ESV and EDV rose during adolescence and declined in adulthood. SV and EF decreased with age. Compared to adult females, adult males had higher BSA-adjusted values of EDV (p = 0.006 and ESV (p Conclusion LV volumes, mass and function vary over a broad age range in healthy individuals. LV volumes and mass both rise in adolescence and decline with age. EF showed a rapid decline in adolescence compared to changes throughout adulthood. These findings demonstrate the need for age and gender specific normal ranges for clinical use.

  18. Atorvastatin therapy during the peri-infarct period attenuates left ventricular dysfunction and remodeling after myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Xian-Liang Tang

    Full Text Available Although statins impart a number of cardiovascular benefits, whether statin therapy during the peri-infarct period improves subsequent myocardial structure and function remains unclear. Thus, we evaluated the effects of atorvastatin on cardiac function, remodeling, fibrosis, and apoptosis after myocardial infarction (MI. Two groups of rats were subjected to permanent coronary occlusion. Group II (n = 14 received oral atorvastatin (10 mg/kg/d daily for 3 wk before and 4 wk after MI, while group I (n = 12 received equivalent doses of vehicle. Infarct size (Masson's trichrome-stained sections was similar in both groups. Compared with group I, echocardiographic left ventricular ejection fraction (LVEF and fractional area change (FAC were higher while LV end-diastolic volume (LVEDV and LV end-systolic and end-diastolic diameters (LVESD and LVEDD were lower in treated rats. Hemodynamically, atorvastatin-treated rats exhibited significantly higher dP/dt(max, end-systolic elastance (Ees, and preload recruitable stroke work (PRSW and lower LV end-diastolic pressure (LVEDP. Morphometrically, infarct wall thickness was greater in treated rats. The improvement of LV function by atorvastatin was associated with a decrease in hydroxyproline content and in the number of apoptotic cardiomyocyte nuclei. We conclude that atorvastatin therapy during the peri-infarct period significantly improves LV function and limits adverse LV remodeling following MI independent of a reduction in infarct size. These salubrious effects may be due in part to a decrease in myocardial fibrosis and apoptosis.

  19. Left ventricular function in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Takahashi, Hiromi; Yamaguchi, Ryutaro; Ifuku, Masayasu

    1985-01-01

    The present study was to investigate of left ventricular (LV) function during exercise in 26 patients with hypertrophic cardiomyopathy(HCM) usingTc-99m equilibrium angiocardiography, and to elucidate the mechanism of impaired functional reserve during exercise. In patients with HCM, LV ejection fraction decreased from 65 ± 8 (mean ± SD) % at rest to 59 ± 18 % at peak exercise, in contrast to an increase among controls (from 56 ± 9 % to 64 ± 9 %). As compared with resting values, cardiac output increased to 168 ± 24 % at peak exercise in HCM, but the increase was significantly less than that in controls (215 ± 47 %). Stroke volume decreased gradually to 83 ± 16 % during exercise in HCM, while it increased to 114 ± 10 % at an exercise level of half intensity, and it decreased slightly to 106 ± 16 % at peak exercise. LV end-systolic volume decreased among controls to 78 ± 27 % at peak exercise, but remained unchanged in HCM (118 ± 58 %). An increase in peak ejection rate at peak exercise was less in HCM than in controls (143 ± 26 % vs 170 ± 42 %). No significant differences were observed between the two groups concerning changes in indices of LV diastolic function including LV end-diastolic volume, peak filling rate or 1/3 filling rate during exercise. In the analysis of LV function curves, pulmonary arterial diastolic pressure increased to a greater extent in HCM than in controls (19 ± 6 mmHg vs 11 ± 6 mmHg); whereas, an increase in the stroke work index was less in HCM (80 ± 26 g.m/m 2 /beat vs 121 ± 21 g.m/m 2 /beat) at peak exercise. Thus, the LV function curve shifted downward and to the right in patients with HCM. The above findings indicate that LV functional reserve during exercise is impaired, especially as to systolic function in patients with HCM, while deterioration of diastolic function may be partly compromised by elevated filling pressure. (J.P.N.)

  20. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  1. Evaluation of Left Ventricular Diastolic Dysfunction with Early Systolic Dysfunction Using Two-Dimensional Speckle Tracking Echocardiography in Canine Heart Failure Model.

    Science.gov (United States)

    Wu, Wei-Chun; Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Tang, Yue; Wang, Hao

    2016-04-01

    This study evaluated the role of two-dimensional speckle tracking echocardiography (2DSTE) for predicting left ventricular (LV) diastolic dysfunction in pacing-induced canine heart failure. Pacing systems were implanted in 8 adult mongrel dogs, and continuous rapid right ventricular pacing (RVP, 240 beats/min) was maintained for 2 weeks. The obtained measurements from 2DSTE included global strain rate during early diastole (SRe) and during late diastole (SRa) in the longitudinal (L-SRe, L-SRa), circumferential (C-SRe, C-SRa), and radial directions (R-SRe, R-SRa). Changes in heart morphology were observed by light microscopy and transmission electron microscopy at 2 weeks. The onset of LV diastolic dysfunction with early systolic dysfunction occurred 3 days after RVP initiation. Most of the strain rate imaging indices were altered at 1 or 3 days after RVP onset and continued to worsen until heart failure developed. Light and transmission electron microscopy showed myocardial vacuolar degeneration and mitochondrial swelling in the left ventricular at 2 weeks after RVP onset. Pearson's correlation analysis revealed that parameters of conventional echocardiography and 2DSTE showed moderate correlation with LV pressure parameters, including E/Esep' (r = 0.58, P echocardiography and strain rate imaging could effectively predict LV diastolic dysfunction (area under the curve: E/Esep' 0.78; L-SRe 0.84; E/L-SRe 0.80; R-SRe 0.80). 2DSTE was a sensitive and accurate technique that could be used for predicting LV diastolic dysfunction in canine heart failure model. © 2015, Wiley Periodicals, Inc.

  2. EFFECT OF MITRAL REGURGITATION ON CHRONIC HEART FAILURE COURSE AND STRUCTURE-FUNCTIONAL HEART STATE

    Directory of Open Access Journals (Sweden)

    V. N. Larina

    2009-01-01

    Full Text Available Aim. To evaluate chronic heart failure (CHF course, functional and structural heart changes in patients with functional mitral regurgitation (MR of various degrees.Material and methods. A total of 104 outpatients (60-85 y. o. with CHF of functional class II-IV by NYHA and functional MR of I-II degrees and MR of III-IV degrees were included into the study groups.Results: Patients in both groups were comparable in sex, age, CHF duration, body mass index, systolic and diastolic blood pressure, clinical state by the clinical state scale, quality of life, anxious and depressive status. The majority of patients with MR III had significant left ventricle (LV systolic dysfunction (p=0,029, severe CHF course (p=0,034, received furosemide (p=0.004 and digoxin (p=0,004. They had significant increase in end-diastolic dimension (p<0,001, end-systolic dimension (p<0,001, left atrium (p=0,004, end-diastolic volume (p<0,001, end-systolic volume (p<0,001, pulmonary artery pressure (p<0,001, decrease in LV relative wall thickness (p=0,021 and LV ejection fraction (p<0,001. Patients of this group were hospitalized because of CHF decompensation and ischemic heart disease exacerbation more often (p=0,045.Conclusion. MR can be considered as one of sensitive predictors of LV geometry and function alteration in CHF patients and play an important role in symptoms development.

  3. EFFECT OF MITRAL REGURGITATION ON CHRONIC HEART FAILURE COURSE AND STRUCTURE-FUNCTIONAL HEART STATE

    Directory of Open Access Journals (Sweden)

    V. N. Larina

    2016-01-01

    Full Text Available Aim. To evaluate chronic heart failure (CHF course, functional and structural heart changes in patients with functional mitral regurgitation (MR of various degrees.Material and methods. A total of 104 outpatients (60-85 y. o. with CHF of functional class II-IV by NYHA and functional MR of I-II degrees and MR of III-IV degrees were included into the study groups.Results: Patients in both groups were comparable in sex, age, CHF duration, body mass index, systolic and diastolic blood pressure, clinical state by the clinical state scale, quality of life, anxious and depressive status. The majority of patients with MR III had significant left ventricle (LV systolic dysfunction (p=0,029, severe CHF course (p=0,034, received furosemide (p=0.004 and digoxin (p=0,004. They had significant increase in end-diastolic dimension (p<0,001, end-systolic dimension (p<0,001, left atrium (p=0,004, end-diastolic volume (p<0,001, end-systolic volume (p<0,001, pulmonary artery pressure (p<0,001, decrease in LV relative wall thickness (p=0,021 and LV ejection fraction (p<0,001. Patients of this group were hospitalized because of CHF decompensation and ischemic heart disease exacerbation more often (p=0,045.Conclusion. MR can be considered as one of sensitive predictors of LV geometry and function alteration in CHF patients and play an important role in symptoms development.

  4. CXL-1020, a Novel Nitroxyl (HNO Prodrug, Is More Effective than Milrinone in Models of Diastolic Dysfunction—A Cardiovascular Therapeutic: An Efficacy and Safety Study in the Rat

    Directory of Open Access Journals (Sweden)

    Steve R. Roof

    2017-11-01

    Full Text Available The nitroxyl (HNO prodrug, CXL-1020, induces vasorelaxation and improves cardiac function in canine models and patients with systolic heart failure (HF. HNO's unique mechanism of action may be applicable to a broader subset of cardiac patients. This study investigated the load-independent safety and efficacy of CXL-1020 in two rodent (rat models of diastolic heart failure and explored potential drug interactions with common HF background therapies. In vivo left-ventricular hemodynamics/pressure-volume relationships assessed before/during a 30 min IV infusion of CXL-1020 demonstrated acute load-independent positive inotropic, lusitropic, and vasodilatory effects in normal rats. In rats with only diastolic dysfunction due to bilateral renal wrapping (RW or pronounced diastolic and mild systolic dysfunction due to 4 weeks of chronic isoproterenol exposure (ISO, CXL-1020 attenuated the elevated LV filling pressures, improved the end diastolic pressure volume relationship, and accelerated relaxation. CXL-1020 facilitated Ca2+ re-uptake and enhanced myocyte relaxation in isolated cardiomyocytes from ISO rats. Compared to milrinone, CXL-1020 more effectively improved Ca2+ reuptake in ISO rats without concomitant chronotropy, and did not enhance Ca2+ entry via L-type Ca2+ channels nor increase myocardial arrhythmias/ectopic activity. Acute-therapy with CXL-1020 improved ventricular relaxation and Ca2+ cycling, in the setting of chronic induced diastolic dysfunction. CXL-1020's lusitropic effects were greater than those seen with the cAMP-dependent agent milrinone, and unlike milrinone it did not produce chronotropy or increased ectopy. HNO is a promising new potential therapy for both systolic and diastolic heart failure.

  5. Doppler echocardiographic study in adolescents and young adults with sickle cell anemia

    Directory of Open Access Journals (Sweden)

    Wolney de Andrade Martins

    1999-12-01

    Full Text Available OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA. METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS. The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.

  6. Estimation of left ventricular operating stiffness from Doppler early filling deceleration time in humans.

    Science.gov (United States)

    Garcia, M J; Firstenberg, M S; Greenberg, N L; Smedira, N; Rodriguez, L; Prior, D; Thomas, J D

    2001-02-01

    Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.

  7. Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot.

    Science.gov (United States)

    Kim, Ho Jin; Mun, Da Na; Goo, Hyun Woo; Yun, Tae-Jin

    2017-04-01

    Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m 2 vs. 175 mL/m 2 , p=0.008; median LV-EDVI: 94 mL/m 2 vs. 92 mL/m 2 , p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

  8. Effects of coil closure of patent ductus arteriosus on left anterior descending coronary artery blood flow using transthoracic Doppler echocardiography.

    Science.gov (United States)

    Harada, Kenji; Toyono, Manotomo; Tamura, Masamichi

    2004-06-01

    Transthoracic Doppler echocardiography provides noninvasive measurements of coronary blood flow in the left anterior descending coronary artery (LAD). This method has the potential to show the effects of acute changes in loading conditions on blood flow. Coil closure of patent ductus arteriosus (PDA) is a model of acute changes in blood pressure and left ventricular (LV) preload that influences coronary blood flow. We applied this technique to assess the coronary blood flow changes for patients with PDA before and immediately after PDA coil closure. We examined 9 patients (1.8 +/- 1.1 years) with simple PDA and 8 age-matched healthy children. LV dimensions and LV mass were measured. Maximum peak flow velocity and flow volume in the LAD were measured. Pulmonary to systemic flow ratios (Qp/Qs) were obtained by cardiac catheterization. After PDA coil closure, LV end-diastolic dimension decreased, and systolic and diastolic blood pressures increased significantly. The maximum peak flow velocity, LAD flow volume, and the ratio of LAD flow volume to LV mass increased significantly. The changes in maximum peak flow velocity and the ratio of LAD flow volume to LV mass (F/M) correlated positively with the changes in diastolic pressure and Qp/Qs. In 5 patients who had Qp/Qs > 1.5, the mean F/M was significantly lower compared with control subjects, but they increased to normal values after coil closure of PDA. PDA coil closure increases diastolic pressure and decreases Qp/Qs, resulting in improvement of myocardial perfusion. These findings provide new insights into the relationship between cardiac function and coronary circulation in pediatric patients with heart diseases associated with PDA.

  9. Cardiac adaptations to high-intensity aerobic training in premenopausal and recent postmenopausal women

    DEFF Research Database (Denmark)

    Egelund, Jon; Jørgensen, Peter Godsk; Mandrup, Camilla M

    2017-01-01

    and after a 12-week period of high-intensity aerobic cycle training. LV internal diastolic diameter and LV mass were similar in the 2 groups at baseline and increased by ≈2% to 8% (P=0.04-0.0007) with training in both groups. Left atrial end-diastolic and end-systolic volumes were similar for both groups......BACKGROUND: We examined the role of menopause on cardiac dimensions and function and assessed the efficacy of exercise training before and after menopause. METHODS AND RESULTS: Two groups of healthy premenopausal (n=36, 49.4±0.3 years) and postmenopausal (n=37, 53.5±0.5 years) women with no history...... and increased by 23% to 36% (P=0.0006-0.0001) with training. Systolic function assessed by mean global strain was similar in both groups at baseline and increased by ≈8% (P=0.0004) with training in the postmenopausal group. LV displacement increased by ≈3% (P=0.04) in the premenopausal women only. Diastolic...

  10. The total right/left-volume index: a new and simplified cardiac magnetic resonance measure to evaluate the severity of Ebstein anomaly of the tricuspid valve: a comparison with heart failure markers from various modalities.

    Science.gov (United States)

    Hösch, Olga; Sohns, Jan Martin; Nguyen, Thuy-Trang; Lauerer, Peter; Rosenberg, Christina; Kowallick, Johannes Tammo; Kutty, Shelby; Unterberg, Christina; Schuster, Andreas; Faßhauer, Martin; Staab, Wieland; Paul, Thomas; Lotz, Joachim; Steinmetz, Michael

    2014-07-01

    The classification of clinical severity of Ebstein anomaly still remains a challenge. The aim of this study was to focus on the interaction of the pathologically altered right heart with the anatomically-supposedly-normal left heart and to derive from cardiac magnetic resonance (CMR) a simple imaging measure for the clinical severity of Ebstein anomaly. Twenty-five patients at a mean age of 26±14 years with unrepaired Ebstein anomaly were examined in a prospective study. Disease severity was classified using CMR volumes and functional measurements in comparison with heart failure markers from clinical data, ECG, laboratory and cardiopulmonary exercise testing, and echocardiography. All examinations were completed within 24 hours. A total right/left-volume index was defined from end-diastolic volume measurements in CMR: total right/left-volume index=(RA+aRV+fRV)/(LA+LV). Mean total right/left-volume index was 2.6±1.7 (normal values: 1.1±0.1). This new total right/left-volume index correlated with almost all clinically used biomarkers of heart failure: brain natriuretic peptide (r=0.691; P=0.0003), QRS (r=0.432; P=0.039), peak oxygen consumption/kg (r=-0.479; P=0.024), ventilatory response to carbon dioxide production at anaerobic threshold (r=0.426; P=0.048), the severity of tricuspid regurgitation (r=0.692; P=0.009), tricuspid valve offset (r=0.583; P=0.004), and tricuspid annular plane systolic excursion (r=0.554; P=0.006). Previously described severity indices ([RA+aRV]/[fRV+LA+LV]) and fRV/LV end-diastolic volume corresponded only to some parameters. In patients with Ebstein anomaly, the easily acquired index of right-sided to left-sided heart volumes from CMR correlated well with established heart failure markers. Our data suggest that the total right/left-volume index should be used as a new and simplified CMR measure, allowing more accurate assessment of disease severity than previously described scoring systems. © 2014 American Heart Association, Inc.

  11. Cardiac atrophy after bed rest and spaceflight

    Science.gov (United States)

    Perhonen, M. A.; Franco, F.; Lane, L. D.; Buckey, J. C.; Blomqvist, C. G.; Zerwekh, J. E.; Peshock, R. M.; Weatherall, P. T.; Levine, B. D.

    2001-01-01

    Cardiac muscle adapts well to changes in loading conditions. For example, left ventricular (LV) hypertrophy may be induced physiologically (via exercise training) or pathologically (via hypertension or valvular heart disease). If hypertension is treated, LV hypertrophy regresses, suggesting a sensitivity to LV work. However, whether physical inactivity in nonathletic populations causes adaptive changes in LV mass or even frank atrophy is not clear. We exposed previously sedentary men to 6 (n = 5) and 12 (n = 3) wk of horizontal bed rest. LV and right ventricular (RV) mass and end-diastolic volume were measured using cine magnetic resonance imaging (MRI) at 2, 6, and 12 wk of bed rest; five healthy men were also studied before and after at least 6 wk of routine daily activities as controls. In addition, four astronauts were exposed to the complete elimination of hydrostatic gradients during a spaceflight of 10 days. During bed rest, LV mass decreased by 8.0 +/- 2.2% (P = 0.005) after 6 wk with an additional atrophy of 7.6 +/- 2.3% in the subjects who remained in bed for 12 wk; there was no change in LV mass for the control subjects (153.0 +/- 12.2 vs. 153.4 +/- 12.1 g, P = 0.81). Mean wall thickness decreased (4 +/- 2.5%, P = 0.01) after 6 wk of bed rest associated with the decrease in LV mass, suggesting a physiological remodeling with respect to altered load. LV end-diastolic volume decreased by 14 +/- 1.7% (P = 0.002) after 2 wk of bed rest and changed minimally thereafter. After 6 wk of bed rest, RV free wall mass decreased by 10 +/- 2.7% (P = 0.06) and RV end-diastolic volume by 16 +/- 7.9% (P = 0.06). After spaceflight, LV mass decreased by 12 +/- 6.9% (P = 0.07). In conclusion, cardiac atrophy occurs during prolonged (6 wk) horizontal bed rest and may also occur after short-term spaceflight. We suggest that cardiac atrophy is due to a physiological adaptation to reduced myocardial load and work in real or simulated microgravity and demonstrates the plasticity

  12. Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study

    International Nuclear Information System (INIS)

    Cain, Peter A; Ahl, Ragnhild; Hedstrom, Erik; Ugander, Martin; Allansdotter-Johnsson, Ase; Friberg, Peter; Arheden, Hakan

    2009-01-01

    Knowledge about age-specific normal values for left ventricular mass (LVM), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) by cardiac magnetic resonance imaging (CMR) is of importance to differentiate between health and disease and to assess the severity of disease. The aims of the study were to determine age and gender specific normal reference values and to explore the normal physiological variation of these parameters from adolescence to late adulthood, in a cross sectional study. Gradient echo CMR was performed at 1.5 T in 96 healthy volunteers (11–81 years, 50 male). Gender-specific analysis of parameters was undertaken in both absolute values and adjusted for body surface area (BSA). Age and gender specific normal ranges for LV volumes, mass and function are presented from the second through the eighth decade of life. LVM, ESV and EDV rose during adolescence and declined in adulthood. SV and EF decreased with age. Compared to adult females, adult males had higher BSA-adjusted values of EDV (p = 0.006) and ESV (p < 0.001), similar SV (p = 0.51) and lower EF (p = 0.014). No gender differences were seen in the youngest, 11–15 year, age range. LV volumes, mass and function vary over a broad age range in healthy individuals. LV volumes and mass both rise in adolescence and decline with age. EF showed a rapid decline in adolescence compared to changes throughout adulthood. These findings demonstrate the need for age and gender specific normal ranges for clinical use

  13. Quantitation of right and left ventricular volume with MR imaging in patients with primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Boxt, L.M.; Katz, J.; Kolb, T.; Czegledy, F.P.; Barst, R.J.

    1990-01-01

    This paper tests the utility of MR imaging in quantitating changes in ventricular volume and function in patients with primary pulmonary hypertension (PPH). Right ventricular (RV) and left ventricular (LV) end-diastolic (ED) and end-systolic (ES) volumes were determined in six patients with PPH and in eight controls. Short-axis images were obtained from the cardiac apex to the base at ED and ES, and the ventricular cavities were planimetered. Volumes were computed by summing the areas of the cavities times the thickness of the sections (12-14 mm). The intersection gap (1-3 mm) was averaged between adjacent sections. Results were indexed to the subject's body surface area. This technique was verified by comparison of results obtained by this method with the water displacement volumes of ventricular casts of eight excised bovine hearts and six water-filled balloons. Linear regression and the unpaired Students t test were used to test significance

  14. Performance of new automated transthoracic three-dimensional echocardiographic software for left ventricular volumes and function assessment in routine clinical practice: Comparison with 3 Tesla cardiac magnetic resonance.

    Science.gov (United States)

    Levy, Franck; Dan Schouver, Elie; Iacuzio, Laura; Civaia, Filippo; Rusek, Stephane; Dommerc, Carinne; Marechaux, Sylvestre; Dor, Vincent; Tribouilloy, Christophe; Dreyfus, Gilles

    2017-11-01

    Three-dimensional (3D) transthoracic echocardiography (TTE) is superior to two-dimensional Simpson's method for assessment of left ventricular (LV) volumes and LV ejection fraction (LVEF). Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time-consuming. To evaluate the feasibility, accuracy and reproducibility of new fully automated fast 3D TTE software (HeartModel A.I. ; Philips Healthcare, Andover, MA, USA) for quantification of LV volumes and LVEF in routine practice; to compare the 3D LV volumes and LVEF obtained with a cardiac magnetic resonance (CMR) reference; and to optimize automated default border settings with CMR as reference. Sixty-three consecutive patients, who had comprehensive 3D TTE and CMR examinations within 24hours, were eligible for inclusion. Nine patients (14%) were excluded because of insufficient echogenicity in the 3D TTE. Thus, 54 patients (40 men; mean age 63±13 years) were prospectively included into the study. The inter- and intraobserver reproducibilities of 3D TTE were excellent (coefficient of variation<10%) for end-diastolic volume (EDV), end-systolic volume (ESV) and LVEF. Despite a slight underestimation of EDV using 3D TTE compared with CMR (bias=-22±34mL; P<0.0001), a significant correlation was found between the two measurements (r=0.93; P=0.0001). Enlarging default border detection settings leads to frequent volume overestimation in the general population, but improved agreement with CMR in patients with LVEF≤50%. Correlations between 3D TTE and CMR for ESV and LVEF were excellent (r=0.93 and r=0.91, respectively; P<0.0001). 3D TTE using new-generation fully automated software is a feasible, fast, reproducible and accurate imaging modality for LV volumetric quantification in routine practice. Optimization of border detection settings may increase agreement with CMR for EDV assessment in dilated ventricles. Copyright © 2017 Elsevier Masson

  15. Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2017-04-01

    Full Text Available Background: Cardiac computed tomography (CT has emerged as an alternative to magnetic resonance imaging (MRI for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI in 11 patients (median age, 19 years who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI and semiautomatic 3-dimensional region-growing method (CT were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI, which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI (r=0.88, p<0.001, the right ventricular end-systolic volume index (RV-ESVI (r=0.84, p=0.001, the left ventricular end-diastolic volume index (LV-EDVI (r=0.90, p=0.001, and the LV-ESVI (r=0.55, p=0.079. While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m 2 vs. 175 mL/m 2 , p=0.008; median LV-EDVI: 94 mL/m 2 vs. 92 mL/m 2 , p=0.026, no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

  16. Comparison of frequencies of left ventricular systolic and diastolic heart failure in Chinese living in Hong Kong.

    Science.gov (United States)

    Yip, G W; Ho, P P; Woo, K S; Sanderson, J E

    1999-09-01

    There is a wide variation (13% to 74%) in the reported prevalence of heart failure associated with normal left ventricular (LV) systolic function (diastolic heart failure). There is no published information on this condition in China. To ascertain the prevalence of diastolic heart failure in this community, 200 consecutive patients with the typical features of congestive heart failure were studied with standard 2-dimensional Doppler echocardiography. A LV ejection fraction (LVEF) >45% was considered normal. The results showed that 12.5% had significant valvular heart disease. Of the remaining 175 patients, 132 had a LVEF >45% (75%). Therefore, 66% of patients with a clinical diagnosis of heart failure had a normal LVEF. Heart failure with normal LV systolic function was more common than systolic heart failure in those >70 years old (65% vs 47%; p = 0.015). Most (57%) had an abnormal relaxation pattern in diastole and 14% had a restrictive filling pattern. In the systolic heart failure group, a restrictive filling pattern was more common (46%). There were no significant differences in the sex distribution, etiology, or prevalence of LV hypertrophy between these 2 heart failure groups. In conclusion, heart failure with a normal LVEF or diastolic heart failure is more common than systolic heart failure in Chinese patients with the symptoms of heart failure. This may be related to older age at presentation and the high prevalence of hypertension in this community.

  17. Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction

    International Nuclear Information System (INIS)

    Navare, Sachin M.; Liu, Yi-Hwa; Wackers, Frans J.T.

    2003-01-01

    Electrocardiographic (ECG) gated single-photon emission tomography (SPET) allows for simultaneous assessment of myocardial perfusion and left ventricular (LV) function. Presently 8-frame per cardiac cycle ECG gating of SPET images is standard. The aim of this study was to compare the effect of 8-frame and 16-frame gated SPET on measurements of LV volumes and to evaluate the effects of the presence of myocardial perfusion defects and of radiotracer dose administered on the calculation of LV volumes. A total of 86 patients underwent technetium-99m SPET myocardial perfusion imaging using 16-frame per cardiac cycle acquisition. Eight-frame gated SPET images were generated by summation of contiguous frames. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated from the 16-frame and 8-frame data sets. The patients were divided into groups according to the administered dose of the radiotracer and the size of the perfusion defect. Results. Sixteen frame per cardiac cycle acquisition resulted in significantly larger EDV (122±72 ml vs 115±68 ml, P<0.0001), smaller ESV (64±58.6 ml vs 67.6±59.5 ml, P<0.0001), and higher LVEF (55.3%±18% vs 49%±17.4%, P<0.0001) as compared to 8-frame SPET imaging. This effect was seen regardless of whether a high or a low dose was administered and whether or not significant perfusion defects were present. This study shows that EDV, ESV and LVEF determined by 16-frame gated SPET are significantly different from those determined by 8-frame gated SPET. The radiotracer dose and perfusion defects do not affect estimation of LV parameters by 16-frame gated SPET. (orig.)

  18. Determinants of global left ventricular peak diastolic filling rate during rest and exercise in normal volunteers

    International Nuclear Information System (INIS)

    Filiberti, A.W.; Bianco, J.A.; Baker, S.P.; Doherty; Nalivaika, L.A.; King, M.A.; Alpert, J.S.

    1984-01-01

    Early peak diastolic filling rate (PFR) of the left ventricle (LV) is said to be a sensitive index of LV dysfunction in patients with coronary disease, hypertension and hypertrophic cardiomyopathy. Radionuclide (RN0 multigated PFR was measured in 20 normal volunteers (13 males, 7 females, mean age 31 yrs., range 20-43) at rest and during supine bicycle exercise conducted to a symptomatic end-point. At rest, RN PFR was 3.4 +- SD 0.4 end-diastolic vols./sec (range 3.1 - 3.6). During exercise all normal volunteers had a progressive and numerically and statistically significant increase in PFR. Stepwise multiple linear regression (BMPD2R) was applied to the rest and exercise PFR data to develop a linear model describing the main determinants of the RN PFR. The potential independent variables which were included in the model were heart rate (HR), ejection fraction (EF), systolic arterial pressure, systolic ejection rate and exercise stage. Ranking of variables for prediction of RN PFR, and exclusion of less important variables, was done by F value criteria. The final multivariate equation was: LVPFR = -3.84437 + 0.03834 HR + 0.07537 LVEF. The model fit was highly significant (p<0.001), and accounted for 89 per cent of variability in the PFR. The authors conclude that the left ventricular peak filling rate is critically determined by heart rate and by ejection fraction at rest and during exercise

  19. High baseline left ventricular and systolic volume may identify patients at risk of chemotherapy-induced cardiotoxicity

    International Nuclear Information System (INIS)

    Atiar Rahman; Alex Gedevanishvili; Seham Ali; Elma G Briscoe; Vani Vijaykumar

    2004-01-01

    Introduction and Methods: Use of chemotherapeutic drugs in the treatment of cancer may lead to serious cardiotoxicity and to post-treatment heart failure. Various strategies have been developed to minimize the risk of cardiotoxicity including avoiding the total dosage given to each patient above a certain 'threshold' value; and monitoring the patient's cardiac function by means of the 'Multiple Gated Acquisition' (MUGA) scan using Technetium 99m . However, even with all these precautions some patients still develop cardiotoxicity and it is not well known which factors predict deterioration of cardiac functions in patients with optimized chemotherapeutic dosages. In this retrospective study we sought to evaluate the predictive value of seven variables (age, sex, baseline LV ejection fraction, LV end diastolic [LDEDV] and end systolic volumes [LVESV], peak diastolic filling rate, preexisting malignancies requiring chemotherapy) in 172 patients (n=Breast Carcinoma 86, lymphoma 62, Leukemias and others 24) undergoing chemotherapy from 1995 until 2000. There was no cut off for left ventricular ejection fraction prior to chemotherapy. However, patients were excluded from analysis if they had significant cardiac arrhythmias or received doses higher than considered safe for cardiotoxicity at the beginning of the study. Significant cardiotoxicity was defined as a drop in post chemotherapy LVEF by >15%. Results: Logistic regression models were used to predict the probability of developing cardiotoxicity as a function of the seven prognostic covariates. The mean age of all patients was 51+13 years. Significant Cardiac toxicity was noted in 10 percent of patients. The overall risk estimate for subsequent heart failure after chemotherapy, however, climbed to 18 percent in patients with a presenting LVESD >50 mL. Using multivariate logistic regression model, older age was noted to be a weak risk factors for cardiac toxicity (confidence interval 0.8-1.2; p 50 mL) appeared to

  20. Noninvasive and invasive evaluation of cardiac dysfunction in experimental diabetes in rodents

    Directory of Open Access Journals (Sweden)

    Salemi Vera

    2007-04-01

    Full Text Available Abstract Background Because cardiomyopathy is the leading cause of death in diabetic patients, the determination of myocardial function in diabetes mellitus is essential. In the present study, we provide an integrated approach, using noninvasive echocardiography and invasive hemodynamics to assess early changes in myocardial function of diabetic rats. Methods Diabetes was induced by streptozotocin injection (STZ, 50 mg/kg. After 30 days, echocardiography (noninvasive at rest and invasive left ventricular (LV cannulation at rest, during and after volume overload, were performed in diabetic (D, N = 7 and control rats (C, N = 7. The Student t test was performed to compare metabolic and echocardiographic differences between groups at 30 days. ANOVA was used to compare LV invasive measurements, followed by the Student-Newman-Keuls test. Differences were considered significant at P Results Diabetes impaired LV systolic function expressed by reduced fractional shortening, ejection fraction, and velocity of circumferential fiber shortening compared with that in the control group. The diabetic LV diastolic dysfunction was evidenced by diminished E-waves and increased A-waves and isovolumic relaxation time. The myocardial performance index was greater in diabetic compared with control rats, indicating impairment in diastolic and systolic function. The LV systolic pressure was reduced and the LV end-diastolic pressure was increased at rest in diabetic rats. The volume overload increased LVEDP in both groups, while LVEDP remained increased after volume overload only in diabetic rats. Conclusion These results suggest that STZ-diabetes induces systolic and diastolic dysfunction at rest, and reduces the capacity for cardiac adjustment to volume overload. In addition, it was also demonstrated that rodent echocardiography can be a useful, clinically relevant tool for the study of initial diabetic cardiomyopathy manifestations in asymptomatic patients.

  1. Left cardiac chambers reverse remodeling after percutaneous mitral valve repair with the MitraClip system.

    Science.gov (United States)

    Scandura, Salvatore; Ussia, Gian Paolo; Capranzano, Piera; Caggegi, Anna; Sarkar, Kunal; Cammalleri, Valeria; Mangiafico, Sarah; Chiarandà, Marta; Immè, Sebastiano; Di Pasqua, Fabio; Pistritto, Anna Maria; Millan, Giovanni; Tamburino, Corrado

    2012-10-01

    Successful mitral valve surgical repair, decreasing volume overload, has been shown to provide reverse left ventricular (LV) and/or left atrial remodeling in most patients. Percutaneous mitral valve repair with the MitraClip system (Abbott, Abbott Park, IL) has been associated with favorable clinical outcomes in patients with mitral regurgitation at high risk of surgery. However, specific data on left cardiac chambers reverse remodeling after such procedures are limited. This was a prospective observational study of consecutive patients at high risk of surgery, with moderate-to-severe or severe mitral regurgitation undergoing MitraClip system implantation. Follow-up echocardiography was performed at 6 months. The evaluated parameters were the LV end-diastolic and end-systolic volume indexes, LV sphericity index, LV ejection fraction, and left atrial volume index. Reverse LV remodeling was defined as a decrease of 10% in the LV end-diastolic volume index. The study population included 44 patients: 14 with degenerative and 30 with functional mitral regurgitation. At 6 months of follow-up, significant reductions in the median and interquartile range of the sphericity index (from 0.57 [interquartile range 0.54-0.62] to 0.54 [interquartile range 0.50-0.58]; P interquartile range 63.0-102.2] to 60.7 mL/m(2) [50.8-84.4]; P interquartile range 28.2-70.5] to 28.9 mL/m(2) [interquartile range 22.2-55.8]; P interquartile range 30.0-55.0%] to 46.0% [interquartile range 35.0-58.0%]; P < .001) from baseline to 6 months. Minor differences in the left atrial volume index were observed. Reverse remodeling, according to the specified definition, was observed in 77.3% of the patients. The present study reports positive LV reshape effects after mitral valve repair with the MitraClip system, showing significant improvements in LV size and function. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  2. Diastolic dysfunction is associated with insulin resistance, but not with aldosterone level in normotensive offspring of hypertensive families.

    Science.gov (United States)

    Zizek, Bogomir; Poredos, Pavel; Trojar, Andrej; Zeljko, Tadej

    2008-01-01

    We investigated left ventricular (LV) morphology and function in association with insulin level/insulin resistance (IR) and aldosterone level in normotensive offspring of subjects with essential hypertension (familial trait, FT). The study encompassed 76 volunteers of whom 44 were normotensive with FT (aged 28-39 years) and 32 age-matched controls without FT. LV mass and function were measured using conventional echocardiography and tissue Doppler imaging. LV diastolic function was reported as peak septal annular velocities (E(m) and E(m)/A(m) ratio) in tissue Doppler imaging. Fasting insulin and aldosterone were determined. In subjects with FT, the LV mass was higher than in controls (92.14 +/- 24.02 vs. 70.08 +/- 20.58 g; p < 0.001). The study group had a worse LV diastolic function than control subjects (lower E(m) and E(m)/A(m) ratio; p < 0.001). In subjects with FT, the E(m)/A(m) ratio was independently associated with IR (partial p = 0.029 in multivariate model, R(2) = 0.51), but not with LV mass. The aldosterone level was comparable in both groups. In normotensive individuals with FT, LV morphological and functional abnormalities were found. LV dysfunction but not an increase in LV mass is associated with IR. The aldosterone level is probably not responsible for the development of early hypertensive heart disease. (c) 2008 S. Karger AG, Basel.

  3. Association of left ventricular longitudinal and circumferential systolic dysfunction with diastolic function in hypertension: a nonlinear analysis focused on the interplay with left ventricular geometry.

    Science.gov (United States)

    Ballo, Piercarlo; Nistri, Stefano; Cameli, Matteo; Papesso, Barbara; Dini, Frank Lloyd; Galderisi, Maurizio; Zuppiroli, Alfredo; Mondillo, Sergio

    2014-02-01

    The relationships of left ventricular (LV) longitudinal and circumferential systolic dysfunction with diastolic performance in hypertensive patients have never been compared. In 532 asymptomatic hypertensive patients, circumferential function was assessed with the use of midwall fractional shortening (mFS) and stress-corrected mFS (SCmFS), whereas longitudinal function was assessed with the use of left atrioventricular plane displacement (AVPD) and systolic mitral annulus velocity (s'). Early diastolic annular velocity (e') and the E/e' ratio were measured. Global longitudinal and circumferential strain were determined in a subset of 210 patients. e' was linearly related to all systolic indexes (AVPD: R = 0.40; s': R = 0.39; mFS: R = 0.16; SCmFS: R = 0.17; all P SCmFS. Longitudinal indexes were superior to circumferential ones in predicting e' <8 cm/s, E/e' <8, and E/e' ≥13. The effect of LV geometry on LV diastolic function was evident among patients with preserved systolic longitudinal function, but was blunted among patients with impaired longitudinal function. In multivariable analyses, only longitudinal indexes remained associated with e' and E/e'. Analyses using strains provided similar results. In asymptomatic hypertensive subjects, LV diastolic performance is independently associated with longitudinal systolic dysfunction, but not with circumferential systolic dysfunction. Subtle longitudinal systolic impairment plays a role in mediating the effect of LV geometry on diastolic performance. These findings may support the need of critically revising the concept of isolated diastolic dysfunction in these patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Relationship between left ventricular mechanics and low free triiodothyronine levels after myocardial infarction: a prospective study.

    Science.gov (United States)

    Jankauskienė, Edita; Orda, Paulius; Barauskienė, Greta; Mickuvienė, Narseta; Brožaitienė, Julija; Vaškelytė, Jolanta Justina; Bunevičius, Robertas

    2016-04-01

    Low free triiodothyronine (fT3) levels following acute myocardial infarction (AMI) are associated with greater impairment in cardiac mechanics compared with patients with AMI who have normal values of thyroid hormones. The objectives are to investigate left ventricular (LV) function and mechanics during a 6-month follow-up after myocardial infarction and to evaluate their prognostic implication using two-dimensional (2D) echocardiography and 2D speckle-tracking echocardiography in patients with low fT3 levels. The study design is prospective cohort study. One hundred forty patients with first-onset AMI were grouped according to serum fT3 levels: low fT3 group (fT3 3.2 pmol/L; n = 96). Low levels of fT3 were associated with greater LV diameters and LV end-diastolic volume, and decreased systolic LV function. Systolic apical and basal rotation, peak systolic global longitudinal strain and strain rate, and LV twist and torsion were significantly decreased in the low fT3 group. The prognostic implication for predicting low fT3 levels was evaluated using ROC analysis. LV end-diastolic diameter index is the most sensitive (94.12 %), but has low specificity (37.93 %; area = 0.659, p = 0.01). By contrast, LV end-systolic volume is the most specific (94.03 %), but has low sensitivity (26.32 %; area = 0.594, p = 0.04). Low fT3 levels are significantly associated with worse LV mechanics. Low fT3 levels are important for prediction of LV structure, function, rotation, and deformation parameters during the late post-myocardial infarction period.

  5. Effects of cardiac energy efficiency in diastolic heart failure. Assessment with positron emission tomography with 11C-acetate

    International Nuclear Information System (INIS)

    Hasegawa, Shinji; Yamamoto, Kazuhiro; Sakata, Yasushi; Takeda, Yasuharu; Kajimoto, Katsufumi; Kanai, Yasukazu; Hori, Masatsugu; Hatazawa, Jun

    2008-01-01

    Diastolic heart failure (DHF) has become a high social burden, and its major underlying cardiovascular disease is hypertensive heart disease. However, the pathogenesis of DHF remains to be clarified. This study aimed to assess the effects of cardiac energy efficiency in DHF patients. 11 C-Acetate positron emission tomography and echocardiography were conducted in 11 DHF Japanese patients and 10 normal volunteers. The myocardial clearance rate of radiolabeled 11 C-acetate was measured to calculate the work metabolic index (WMI), an index of cardiac efficiency. The ratio of peak mitral E wave velocity to peak early diastolic septal myocardial velocity (E/e') was calculated to assess left ventricular (LV) filling pressure. The LV mass index was greater and the mean age was higher in the DHF patients than in the normal volunteers. There was no difference in WMI between the two groups. However, WMI varied widely among the DHF patients and was inversely correlated with E/e' (r=-0.699, p=0.017). In contrast, there was no correlation in the normal volunteers. In conclusion, the inefficiency of energy utilization is not a primary cause of diastolic dysfunction or DHF, and cardiac efficiency may not affect diastolic function in normal hearts. However, the energy-wasting state may induce the elevation of LV filling pressure in DHF patients, which was considered to principally result from the progressive diastolic dysfunction. (author)

  6. Prediction of infarct volume in patients undergoing reperfusion therapy by Tc-99m antimyosin SPECT

    International Nuclear Information System (INIS)

    Yasuda, T.; Leinbach, R.C.; Khaw, B.A.; Gold, H.K.; Strauss, H.W.

    1984-01-01

    The predictability of infarct volume by Tc-99m antimyosin SPECT was evaluated within 24 hours of chest pain and this was compared to the length of akinesis (AK) from the pre-discharge left ventriculogram (LVgram). Ten patients (pts) with acute myocardial infarction who underwent streptokinase thrombolytic therapy (success 8, failure 2) were subjects of this investigation. None had previous infarction. Average reperfusion time was within 4.5 hours and 20mCi of Tc-99m antimyosin was given intravenously within 8 hours after chest pain; SPECT imaging was performed within 18 hours after injection. Infarct volume was calculated from SPECT and expressed as grams of myocardial infarction (GMI). Ten days later, a 30 0 RAO contrast LVgram was recorded and the length of AK (corrected for magnification) was measured along the LV border at the end-diastolic phase and expressed as cm of AK. GMI and AK were measured independently without knowledge of each other. Results are given. The data demonstrate a good correlation of GMI and AK. Infarct volume can be measured by antimyosin SPECT within 24 hours of chest pain and predict residual LV dysfunction in pts undergoing reperfusion therapy

  7. Sildenafil and diastolic dysfunction after acute myocardial infarction in patients with preserved ejection fraction

    DEFF Research Database (Denmark)

    Andersen, Mads J; Ersbøll, Mads; Axelsson, Anna

    2013-01-01

    with diastolic dysfunction after myocardial infarction. METHODS AND RESULTS: Seventy patients with diastolic dysfunction and near normal left ventricular ejection fraction on echocardiography were randomly assigned sildenafil 40 mg thrice daily or matching placebo for 9 weeks. Before randomization and after 9......, and systemic vascular resistance index (resting, P=0.0002; peak exercise, P=0.007) and diastolic blood pressure (resting, P=0.005; peak exercise, P=0.02) were lower in the sildenafil group. Resting left ventricular end-diastolic volume index increased (P=0.001) within the sildenafil group but was unchanged...

  8. Changes in Mitral Annular Ascent with Worsening Echocardiographic Parameters of Left Ventricular Diastolic Function

    Directory of Open Access Journals (Sweden)

    Paula M. Hernández Burgos

    2016-01-01

    Full Text Available Background. While the mitral annular plane systolic excursion (MAPSE has been suggested as a surrogate measurement of left ventricular ejection fraction, less is known about the relative value of mitral annular ascent (MAa. Methods. Our database was queried for complete transthoracic echocardiograms performed for any clinical indication. Baseline echocardiographic measurements were compared to determine any correlation between MAa and traditional Echo-Doppler echocardiographic measures to characterize left ventricular diastolic dysfunction (LVDD. Results. Patients with normal LV diastolic function were younger (41±13 years than patients with LVDD (stage 1: 61±13 years; stage 2: 57±14 years; and stage 3: 66±17 years; p=0.156. LV ejection fraction decreased in patients with stage 2 LVDD (63±17% and was further reduced in patients with stage 3 LVDD (28±21; p=0.003. Discussion. While a vigorous MAa excursion was seen in patients with stage 1 LVDD, MAa significantly decreased in stage 2 and stage 3 LVDD patients. Our results highlight the importance of atrioventricular coupling, as MAa motion seems to reflect changes in left atrial pressure. Additional studies are now required to better examine atrioventricular interactions and electromechanical coupling that might improve our assessment of LV diastolic function.

  9. Urinary type IV collagen is related to left ventricular diastolic function and brain natriuretic peptide in hypertensive patients with prediabetes.

    Science.gov (United States)

    Iida, Masato; Yamamoto, Mitsuru; Ishiguro, Yuko S; Yamazaki, Masatoshi; Ueda, Norihiro; Honjo, Haruo; Kamiya, Kaichirou

    2014-01-01

    Urinary type IV collagen is an early biomarker of diabetic nephropathy. Concomitant prediabetes (the early stage of diabetes) was associated with left ventricular (LV) diastolic dysfunction and increased brain natriuretic peptide (BNP) in hypertensive patients. We hypothesized that urinary type IV collagen may be related to these cardiac dysfunctions. We studied hypertensive patients with early prediabetes (HbA1c 110, n=18), those with prediabetes (HbA1c 5.7-6.4, n=98), and those with diabetes (HbA1c>6.5 or on diabetes medications, n=92). The participants underwent echocardiography to assess left atrial volume/body surface area (BSA) and the ratio of early mitral flow velocity to mitral annular velocity (E/e'). Left ventricular diastolic dysfunction (LVDD) was defined if patients had E/e'≥15, or E/e'=9-14 accompanied by left atrial volume/BSA≥32ml/mm(2). Urinary samples were collected for type IV collagen and albumin, and blood samples were taken for BNP and HbA1c. Urinary type IV collagen and albumin increased in parallel with the deterioration of glycemic status. In hypertensive patients with prediabetes, subjects with LVDD had higher levels of BNP and urinary type IV collagen than those without LVDD. In contrast, in hypertensive patients with diabetes, subjects with LVDD had higher urinary albumin and BNP than those without LVDD. Urinary type IV collagen correlated positively with BNP in hypertensive patients with prediabetes, whereas it correlated with HbA1c in those with diabetes. In hypertensive patients with prediabetes, urinary type IV collagen was associated with LV diastolic dysfunction and BNP. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Analysis of end-systolic pressure-volume relation by gated radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Horoki; Katsume, Hiroshi; Ijichi, Hamao; Miyanaga, Hajime

    1982-01-01

    Left ventricular end-systolic pressure-volume relation has been proved experimentally to b e an useful index of left ventricular contractility relatively independent of preload or afterload. But less clinical application has been reported because of its invasive nature, and we evaluated this relationship non-invasively using gated radionuclide angiocardiography as volume determination and cuff sphyngomanometer in the arm as pressure measurement. Gated equilibrium blood pool scintigrams were obtained at rest and during intravenous infusion of angiotensin or nitrate. Ventricular volumes were derived from ventricular activity and peripheral blood volume and activity. The peak systolic pressure (PSP) by cuff method to end-systolic volume index (ESVI) relations showed good linearity (r gt .930 in 84% of consecutive 50 cases) and were gentler in the groups with more impaired left ventricular function. Emax was related exponentially to ejection fraction (EF) and hyperbolically to end-diastolic volume index. The dead volume (VoI) was unfixed and fell into positive or negative value, and was not related to EF under control condition. PSP/ESVI in each loading condition was less variable with the alteration of blood pressure than EF. The linear relation was found between PSP/ESVI under control condition and Emax (PSP/ESVI = 0.651.Emax + 0.958, r = 0.841, p lt .001). Thus in measuring ventricular volume, gated radionuclide angiocardiography is a non-invasive method less affected by the geometry of the left ventricle. Non-invasive determination of end-systolic pressure-volume relation using the volume by radionuclide and the blood pressure by cuff method is clinically useful in the assessment of left ventricular contractility. (author)

  11. Impact of a systolic parameter, defined as the ratio of right brachial pre-ejection period to ejection time, on the relationship between brachial-ankle pulse wave velocity and left ventricular diastolic function.

    Science.gov (United States)

    Hsu, Po-Chao; Lin, Tsung-Hsien; Lee, Chee-Siong; Chu, Chun-Yuan; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2011-04-01

    Arterial stiffness is correlated with left ventricular (LV) diastolic function as well as susceptibility to LV systolic function. Therefore, if LV systolic function is not known, the relationship between arterial stiffness and LV diastolic function is difficult to determine. A total of 260 patients were included in the study. The brachial-ankle pulse wave velocity (baPWV) and the ratio of right brachial pre-ejection period to ejection time (rbPEP/rbET) were measured using an ABI-form device. Patients were classified into four groups. Groups 1, 2, 3 and 4 were patients with rbPEP/rbET and baPWV below the median, rbPEP/rbET above but baPWV below the median, rbPET/rbET below but baPWV above the median, and rbPET/rbET and baPWV above the median, respectively. The LV ejection fractions in groups 1 and 3 were higher than those in groups 2 and 4 (Pwave velocity to Ea that were comparable to those in groups 3 and 4. In conclusion, rbPEP/rbET had an impact on the relationship between baPWV and LV diastolic function. In patients with high rbPEP/rbET but low baPWV, low baPWV may not indicate good LV diastolic function but implies that cardiac dysfunction may precede vascular dysfunction in such patients. When interpreting the relationship between baPWV and LV diastolic function, the rbPEP/rbET value obtained from the same examination should be considered.

  12. Left ventricular volume during supine exercise: importance of myocardial scar in patients with coronary heart disease

    International Nuclear Information System (INIS)

    Mann, D.L.; Scharf, J.; Ahnve, S.; Gilpin, E.

    1987-01-01

    Existing studies suggest that exercise-induced ischemia produces an increase in left ventricular end-diastolic volume; however, all of these studies have included patients with previous myocardial infarction. To test whether the end-diastolic volume response to exercise is related to the extent of myocardial scar, the results of gated radionuclide supine exercise tests performed on 130 subjects were reviewed. The patient group comprised 130 subjects were reviewed. The patient group comprised 130 men aged 35 to 65 years (mean +/- SD 52 +/- 5) with documented coronary heart disease. The extent of myocardial ischemia and scar formation was assessed by stress electrocardiography and thallium-201 scintigraphy. Patients were classified into three groups on the basis of left ventricular end-diastolic volume response at peak exercise: group 1 (n = 72) had an increase of end-diastolic volume greater than 10%, group 2 (n = 41) had a change in end-diastolic volume less than 10% and group 3 (n = 17) had a decrease in end-diastolic volume greater than 10% (n = 17). At rest there was no significant difference among groups in heart rate, systolic blood pressure, end-diastolic (EDVrest) or end-systolic volumes or ejection fraction (p greater than 0.05); however, at peak exercise the end-systolic volume response was significantly greater for group 1 (p less than 0.002)

  13. Left Ventricular Diastolic Function in Type 2 Diabetes Mellitus and the Association With Coronary Artery Calcium Score: A Cardiac MRI Study

    OpenAIRE

    Graça, B; Donato, P; Ferreira, MJ; Castelo-Branco, M; Caseiro-Alves, F

    2014-01-01

    OBJECTIVE: The purpose of this study was to compare cardiac MRI-derived parameters of left ventricular (LV) diastolic function between uncomplicated type 2 diabetes mellitus (DM2) and normoglycemic control subjects and to evaluate whether these parameters of LV diastolic function are related to coronary atherosclerosis. SUBJECTS AND METHODS: We prospectively studied 41 subjects with DM2 and 21 normoglycemic control subjects (30 women and 32 men; mean age, 57.2 ± 7.1 [SD] years) with ...

  14. Tissue advanced glycation end products are associated with diastolic function and aerobic exercise capacity in diabetic heart failure patients

    NARCIS (Netherlands)

    Willemsen, Suzan; Hartog, Jasper W. L.; Hummel, Yoran M.; van Ruijven, Marieke H. I.; van der Horst, Iwan C. C.; van Veldhuisen, Dirk J.; Voors, Adriaan A.

    Aims Advanced glycation end products (AGEs) are increased in patients with diabetes and are associated with diastolic dysfunction through the formation of collagen crosslinks in the heart. The association among AGEs, diastolic function, and aerobic capacity in heart failure (HF) patients with and

  15. Antiremodeling effects on the left ventricle during beta-blockade with metoprolol in the treatment of chronic heart failure

    DEFF Research Database (Denmark)

    Grønning, Bjørn Aaris; Nilsson, J C; Sondergaard, Lars

    2000-01-01

    to the Metoprolol CR/XL Randomized Intervention Trial in Heart Failure (MERIT-HF), 41 patients were examined with magnetic resonance imaging three times in a six-month period, assessing LV dimensions and function. RESULTS: Decreases in both LV end-diastolic volume index (150 ml/m2 at baseline to 126 ml/m2 after six...... months, p = 0.007) and LV end-systolic volume index (107 ml/m2 to 81 ml/m2, p = 0.001) were found, whereas LV ejection fraction increased in the metoprolol CR/XL group (29% to 37%, p = 0.005). No significant changes were seen in the placebo group regarding these variables. Left ventricular stroke volume...... index remained unchanged, whereas LV mass index decreased in both groups (175 g/m2 to 160 g/m2 in the placebo group [p = 0.005] and 179 g/m2 to 164 g/m2 in the metoprolol CR/XL group [p = 0.011). CONCLUSIONS: This study is the first randomized study to demonstrate that the beta1-blocker metoprolol CR...

  16. Cardiac Fibroblast-Dependent Extracellular Matrix Accumulation Is Associated with Diastolic Stiffness in Type 2 Diabetes

    Science.gov (United States)

    Hutchinson, Kirk R.; Lord, C. Kevin; West, T. Aaron; Stewart, James A.

    2013-01-01

    Cardiovascular complications are a leading cause of death in patients with type 2 diabetes mellitus (T2DM). Diastolic dysfunction is one of the earliest manifestations of diabetes-induced changes in left ventricular (LV) function, and results from a reduced rate of relaxation and increased stiffness. The mechanisms responsible for increased stiffness are not completely understood. Chronic hyperglycemia, advanced glycation endproducts (AGEs), and increased levels of proinflammatory and profibrotic cytokines are molecular pathways known to be involved in regulating extracellular matrix (ECM) synthesis and accumulation resulting in increased LV diastolic stiffness. Experiments were conducted using a genetically-induced mouse model of T2DM generated by a point mutation in the leptin receptor resulting in nonfunctional leptin receptors (db/db murine model). This study correlated changes in LV ECM and stiffness with alterations in basal activation of signaling cascades and expression of profibrotic markers within primary cultures of cardiac fibroblasts from diabetic (db/db) mice with nondiabetic (db/wt) littermates as controls. Primary cultures of cardiac fibrobroblasts were maintained in 25 mM glucose (hyperglycemic-HG; diabetic db/db) media or 5 mM glucose (normoglycemic-NG, nondiabetic db/wt) media. The cells then underwent a 24-hour exposure to their opposite (NG; diabetic db/db) media or 5 mM glucose (HG, nondiabetic db/wt) media. Protein analysis demonstrated significantly increased expression of type I collagen, TIMP-2, TGF-β, PAI-1 and RAGE in diabetic db/db cells as compared to nondiabetic db/wt, independent of glucose media concentration. This pattern of protein expression was associated with increased LV collagen accumulation, myocardial stiffness and LV diastolic dysfunction. Isolated diabetic db/db fibroblasts were phenotypically distinct from nondiabetic db/wt fibroblasts and exhibited a profibrotic phenotype in normoglycemic conditions. PMID:23991045

  17. Mitral valve coaptation and its relationship to late diastolic flow: A color Doppler and vector flow map echocardiographic study in normal subjects.

    Science.gov (United States)

    Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard

    2017-04-01

    Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78±16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow. © 2017, Wiley Periodicals, Inc.

  18. ASSESSMENT OF DIASTOLIC DYSFUNCTION, ARTERIAL STIFFNESS, AND CAROTID INTIMA-MEDIA THICKNESS IN PATIENTS WITH ACROMEGALY.

    Science.gov (United States)

    Cansu, Güven Barış; Yılmaz, Nusret; Yanıkoğlu, Atakan; Özdem, Sebahat; Yıldırım, Aytül Belgi; Süleymanlar, Gültekin; Altunbaş, Hasan Ali

    2017-05-01

    Early diagnosis and treatment of cardiovascular diseases, the most frequent cause of morbidity and mortality in acromegaly, may be an efficient approach to extending the lifespan of affected patients. Therefore, it is crucial to determine any cardiovascular diseases in the subclinical period. The study objectives were to determine markers of subclinical atherosclerosis and asses heart structure and function. This was a cross-sectional, single-center study of 53 patients with acromegaly and 22 age- and sex-matched healthy individuals. Carotid intima-media thickness (CIMT), pulse-wave velocity (PWV), and echocardiographic data were compared between these groups. CIMT and PWV were higher in the acromegaly group than in the healthy group (P = .008 and P = .002, respectively). Echocardiography showed that left ventricular diastolic dysfunction was present in 11.3% of patients. Left ventricular mass index and left atrial volume index were higher in the patients (P = .016 and Pacromegaly and the control group. Our results showed that subclinical atherosclerosis (i.e., CIMT and PWV markers) and heart structure and function were worse in patients with acromegaly than in healthy individuals. Because there were no differences in these parameters between patients with controlled and uncontrolled acromegaly, our results suggest that the structural and functional changes do not reverse with biochemical control. AA = active acromegaly BSA = body surface area CA = biochemically controlled acromegaly CH = concentric hypertrophy CIMT = carotid intima-media thickness DBP = diastolic blood pressure DM = diabetes mellitus ECHO = echocardiography EDV = enddiastolic volume EF = ejection fraction ESV = endsystolic volume GH = growth hormone HC = healthy control HL = hyperlipidemia HT = hypertension IGF-1 = insulin-like growth factor 1 LA = left atrial LAV = left atrial volume LAVI = left atrial volume index LV = left ventricular LVDD = left ventricular diastolic dysfunction LVEF = left

  19. Churg-Strauss syndrome associated with rapid deterioration of left ventricular diastolic dysfunction and conduction disturbance.

    Science.gov (United States)

    Chin, Jung Yeon; Yi, Jeong Eun; Youn, Ho-Joong

    2013-10-01

    Cardiac involvement in Churg-Strauss syndrome (CSS) is a major cause of mortality. Here we report a case of a 75-year-old woman with eosinophilic endomyocarditis due to CSS. An electrocardiogram showed intraventricular conduction delay, and echocardiography showed an impaired relaxation pattern and biventricular apical thickening. Magnetic resonance imaging revealed subendocardial delayed enhancement with biventricular apical thrombi. Endomyocardial biopsy showed perivascular eosinophilic infiltration. Despite resolution of the hypereosinophilia after steroid therapy, her left ventricular (LV) diastolic function worsened into a restrictive pattern and she died with a ventricular escape rhythm on her 14th day in the hospital. This case is unusual in that there was rapid progression of the LV diastolic dysfunction and conduction disturbance due to CSS. © 2013, Wiley Periodicals, Inc.

  20. Preoperative left ventricular internal dimension in end-diastole as earlier identification of early patent ductus arteriosus operation and postoperative intensive care in very low birth weight infants.

    Science.gov (United States)

    Saida, Ken; Nakamura, Tomohiko; Hiroma, Takehiko; Takigiku, Kiyohiro; Yasukochi, Satoshi

    2013-10-01

    Patent ductus arteriosus (PDA) is common in premature infants. In very low birth weight infants (VLBWI), PDA requires surgical therapy in many cases. It is unclear to know at-risk infants showing cardio-dysfunction after PDA surgery. The purpose of this study was to identify at-risk infants showing cardio-dysfunction after surgery for patent ductus arteriosus (PDA). We examined the relationship between left ventricular (LV) performance before and after PDA ligation in a retrospective observational cohort study. We studied 64 preterm neonates with symptomatic PDA before and after surgical ligation. Echocardiographic examinations were performed pre- and postoperatively. M-mode measurements included left ventricular internal dimension in end-diastole (LVIDd) and LV fractional shortening (FS). All cases showed decreased LVFS after PDA closure. Most cases (49/64, 77%) showed postoperative FS decreased to below normal (<28%). Preoperative relative LVIDd was significantly larger in abnormal FS infants (137 ± 18%) than in normal FS infants (118 ± 11%; p<0.01). A cut-off value of preoperative relative LVIDd (absolute LVIDd/normal value) for predicting postoperative cardio-dysfunction was 127.4% (sensitivity, 0.735; specificity, 0.933; area under curve, 0.817). Determination of preoperative LVIDd might facilitate earlier identification of infants needing early PDA surgery and postoperative intensive care. © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Interaction of Left Ventricular Remodeling and Regional Dyssynchrony on Long-Term Prognosis after Cardiac Resynchronization Therapy

    DEFF Research Database (Denmark)

    Tayal, Bhupendar; Sogaard, Peter; Delgado-Montero, Antonia

    2017-01-01

    BACKGROUND: Left ventricular (LV) remodeling in heart failure (HF) manifested by chamber dilatation is associated with worse clinical outcomes. However, the impact of LV dilatation on the association of measures of dyssynchrony with long-term prognosis and resynchronization potential after cardiac...... resynchronization therapy (CRT) remains unclear. METHODS: Two hundred sixty CRT patients in New York Heart Association classes II to IV, with ejection fractions ≤ 35% and QRS intervals ≥ 120 msec, were prospectively studied. Quantitative echocardiographic assessment of LV volumes and mechanical dyssynchrony...... of the baseline indexed LV end-diastolic volume (EDVI). Patients with less dilated left ventricles (EDVI left ventricles (EDVI ≥ 90 mL/m(2)) for both primary (adjusted hazard ratio [HR], 2.20; 95% CI, 1.44-3.38; P

  2. Comparison of echocardiographic and cardiac magnetic resonance imaging measurements of functional single ventricular volumes, mass, and ejection fraction (from the Pediatric Heart Network Fontan Cross-Sectional Study).

    Science.gov (United States)

    Margossian, Renee; Schwartz, Marcy L; Prakash, Ashwin; Wruck, Lisa; Colan, Steven D; Atz, Andrew M; Bradley, Timothy J; Fogel, Mark A; Hurwitz, Lynne M; Marcus, Edward; Powell, Andrew J; Printz, Beth F; Puchalski, Michael D; Rychik, Jack; Shirali, Girish; Williams, Richard; Yoo, Shi-Joon; Geva, Tal

    2009-08-01

    Assessment of the size and function of a functional single ventricle (FSV) is a key element in the management of patients after the Fontan procedure. Measurement variability of ventricular mass, volume, and ejection fraction (EF) among observers by echocardiography and cardiac magnetic resonance imaging (CMR) and their reproducibility among readers in these patients have not been described. From the 546 patients enrolled in the Pediatric Heart Network Fontan Cross-Sectional Study (mean age 11.9 +/- 3.4 years), 100 echocardiograms and 50 CMR studies were assessed for measurement reproducibility; 124 subjects with paired studies were selected for comparison between modalities. Interobserver agreement for qualitative grading of ventricular function by echocardiography was modest for left ventricular (LV) morphology (kappa = 0.42) and weak for right ventricular (RV) morphology (kappa = 0.12). For quantitative assessment, high intraclass correlation coefficients were found for echocardiographic interobserver agreement (LV 0.87 to 0.92, RV 0.82 to 0.85) of systolic and diastolic volumes, respectively. In contrast, intraclass correlation coefficients for LV and RV mass were moderate (LV 0.78, RV 0.72). The corresponding intraclass correlation coefficients by CMR were high (LV 0.96, RV 0.85). Volumes by echocardiography averaged 70% of CMR values. Interobserver reproducibility for the EF was similar for the 2 modalities. Although the absolute mean difference between modalities for the EF was small (<2%), 95% limits of agreement were wide. In conclusion, agreement between observers of qualitative FSV function by echocardiography is modest. Measurements of FSV volume by 2-dimensional echocardiography underestimate CMR measurements, but their reproducibility is high. Echocardiographic and CMR measurements of FSV EF demonstrate similar interobserver reproducibility, whereas measurements of FSV mass and LV diastolic volume are more reproducible by CMR.

  3. Prognostic significance of radionuclide-assessed diastolic function in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Chikamori, T.; Dickie, S.; Poloniecki, J.D.; Myers, M.J.; Lavender, J.P.; McKenna, W.J.

    1990-01-01

    To evaluate the prognostic significance of diastolic function in hypertrophic cardiomyopathy (HC), technetium-99m gated equilibrium radionuclide angiography, acquired in list mode, was performed in 161 patients. Five diastolic indexes were calculated. During 3.0 +/- 1.9 years, 13 patients had disease-related deaths. With univariate analysis, these patients were younger (29 +/- 20 vs 42 +/- 16 years; p less than 0.05), had a higher incidence of syncope (p less than 0.025), dyspnea (p less than 0.001), reduced peak filling rate (2.9 +/- 0.9 vs 3.4 +/- 1.0 end-diastolic volume/s; p = 0.09) with increased relative filling volume during the rapid filling period (80 +/- 7 vs 75 +/- 12%; p = 0.06) and decreased atrial contribution (17 +/- 7 vs 22 +/- 11%; p = 0.07). Stepwise discriminant analysis revealed that young age at diagnosis, syncope at diagnosis, reduced peak ejection rate, positive family history, reduced peak filling rate, increased relative filling volume by peak filling rate and concentric left ventricular hypertrophy were the most statistically significant (p = 0.0001) predictors of disease-related death (sensitivity 92%, specificity 76%, accuracy 77%, positive predictive value 25%). Discriminant analysis excluding the diastolic indexes, however, showed similar predictability (sensitivity 92%, specificity 76%, accuracy 78%, positive predictive value 26%). To obtain more homogeneous groups for analysis, patients were classified as survivors or electrically unstable, including sudden death, out-of-hospital ventricular fibrillation and nonsustained ventricular tachycardia during 48-hour ambulatory electrocardiography, and heart failure death or cardiac transplant

  4. Study of the association between left ventricular diastolic impairment and cardiac autonomic neuropathy in diabetic patients using [123I] metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Suzuki, Rokuro; Tanaka, Shiro; Tojo, Osamu; Ishii, Tomofusa; Sato, Toshihiko; Fujii, Satoru; Tumura, Kei.

    1994-01-01

    The association between left ventricular (LV) diastolic dysfunction and myocardial MIBG accumulation was investigated. The subjects were 14 Type II diabetic patients who had no evidence of ischemic heat disease, LV hypertrophy or dilated cardiomyopathy as determined by exercise Tl-201 myocardial scintigraphy and echocardiography. In 14 diabetic patients, isovolumic relaxation time (IRT) was measured by M-mode echocardiography, and the subjects were subdivided into two groups: Group1, 8 patients with impaired left ventricular diastolic function (IRT≥80 msec), and Group 2, 6 patients with normal left ventricular diastolic function (IRT 123 I-MIBG myocardial scintigraphy was performed, and the myocardial accumulation of 123 I-MIBG was investigated. The ratio of myocardial to mediastinal MIBG uptake was significantly (p<0.01) lower in Group 1 than in Group 2. And scintigraphic defects were significantly (p<0.05) more numerous in Group 1 than in Group 2. Patients in Group 1 had a greater frequency of cardiac autonomic neuropathy evaluated by QTc interval and coefficient of variation of R-R interval, when compared with Group 2. These data suggest that, in diabetic patients with no evidence of ischemic heart disease, LV hypertrophy or dilated cardiomyopathy, impairment of left ventricular diastolic function is associated with cardiac autonomic neuropathy. (author)

  5. Prediction of acute cardiac rejection by changes in left ventricular volumes

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.K.; Boniaszczuk, J.

    1988-01-01

    Sixteen patients underwent heart transplantation (11 orthotopic, five heterotopic). Monitoring for acute rejection was by both endomyocardial biopsy (EMB) and multigated equilibrium blood pool scanning with technetium 99m-labelled red blood cells. From the scans information was obtained on left ventricular volumes (stroke, end-diastolic, and end-systolic), ejection fraction, and heart rate. Studies (208) were made in the 16 patients. There was a highly significant correlation between the reduction in stroke volume and end-diastolic volume (and a less significant correlation in end-systolic volume) and increasing acute rejection seen on EMB. Heart rate and ejection fraction did not correlate with the development of acute rejection. Correlation of a combination of changes in stroke volume and end-diastolic volume with EMB showed a sensitivity of 85% and a specificity of 96%. Radionuclide scanning is therefore a useful noninvasive tool for monitoring acute rejection

  6. Diastolic dysfunction predicts new-onset atrial fibrillation and cardiovascular events in patients with acute myocardial infarction and depressed left ventricular systolic function: a CARISMA substudy

    DEFF Research Database (Denmark)

    Jons, Christian; Joergensen, Rikke Moerch; Hassager, Christian

    2010-01-01

    The aim of this study was to investigate the association between diastolic dysfunction and long-term occurrence of new-onset atrial fibrillation (AF) and cardiac events in patients with acute myocardial infarction (AMI) and left ventricular (LV) systolic dysfunction.......The aim of this study was to investigate the association between diastolic dysfunction and long-term occurrence of new-onset atrial fibrillation (AF) and cardiac events in patients with acute myocardial infarction (AMI) and left ventricular (LV) systolic dysfunction....

  7. MR image analysis: Longitudinal cardiac motion influences left ventricular measurements

    International Nuclear Information System (INIS)

    Berkovic, Patrick; Hemmink, Maarten; Parizel, Paul M.; Vrints, Christiaan J.; Paelinck, Bernard P.

    2010-01-01

    Background: Software for the analysis of left ventricular (LV) volumes and mass using border detection in short-axis images only, is hampered by through-plane cardiac motion. Therefore we aimed to evaluate software that involves longitudinal cardiac motion. Methods: Twenty-three consecutive patients underwent 1.5-Tesla cine magnetic resonance (MR) imaging of the entire heart in the long-axis and short-axis orientation with breath-hold steady-state free precession imaging. Offline analysis was performed using software that uses short-axis images (Medis MASS) and software that includes two-chamber and four-chamber images to involve longitudinal LV expansion and shortening (CAAS-MRV). Intraobserver and interobserver reproducibility was assessed by using Bland-Altman analysis. Results: Compared with MASS software, CAAS-MRV resulted in significantly smaller end-diastolic (156 ± 48 ml versus 167 ± 52 ml, p = 0.001) and end-systolic LV volumes (79 ± 48 ml versus 94 ± 52 ml, p < 0.001). In addition, CAAS-MRV resulted in higher LV ejection fraction (52 ± 14% versus 46 ± 13%, p < 0.001) and calculated LV mass (154 ± 52 g versus 142 ± 52 g, p = 0.004). Intraobserver and interobserver limits of agreement were similar for both methods. Conclusion: MR analysis of LV volumes and mass involving long-axis LV motion is a highly reproducible method, resulting in smaller LV volumes, higher ejection fraction and calculated LV mass.

  8. Left Ventricular Diastolic Function in Type 2 Diabetes Mellitus: Prevalence and Association with Myocardial and Vascular Disease

    DEFF Research Database (Denmark)

    Poulsen, Mikael Kjaer; Henriksen, Jan Erik; Dahl, Jordi

    2010-01-01

    and myocardial perfusion. METHODS AND RESULTS: -In a prospective observational study 305 T2DM patients (diabetes duration: 4.5+/-5.3 years) referred consecutively to a diabetes clinic for the first time were screened for LV systolic and diastolic function by echocardiography. Vascular function was estimated...... on myocardial perfusion scintigraphy (MPS) was more frequent in patients with grade 2 diastolic dysfunction and LAVI >32 ml/m(2) compared with those having normal or grade 1 diastolic dysfunction (p=0.002) or LAVI...

  9. Plasma Levels of High Sensitivity Cardiac Troponin T in Adults with Repaired Tetralogy of Fallot

    Science.gov (United States)

    Lai, Clare T. M.; Wong, Sophia J.; Ip, Janice J. K.; Wong, Wai-keung; Tsang, Kwong-cheong; Lam, Wendy W. M.; Cheung, Yiu-fai

    2015-01-01

    Detectable low circulating level of cardiac troponin T (cTnT) may reflect subclinical myocardial injury. We tested the hypothesis that circulating levels of hs-cTnT are altered in adults with repaired tetralogy of Fallot (TOF) and associated with ventricular volume load and function. Eighty-eight TOF patients and 48 controls were studied. Plasma hs-cTnT levels were determined using a highly sensitive assay (hs-cTnT). The right (RV) and left ventricular (LV) volumes and ejection fraction (EF) were measured using 3D echocardiography and, in 52 patients, cardiac magnetic resonance (CMR). The median (interquartile range) for male and female patients were 4.87 (3.83–6.62) ng/L and 3.11 (1.00–3.87) ng/L, respectively. Thirty percent of female but none of the male patients had increased hs-cTnT levels. Female patients with elevated hs-cTnT levels, compared to those without, had greater RV end-diastolic and end-systolic volumes and LV systolic dyssynchrony index (all p < 0.05). For patient cohort only, hs-cTnT levels correlated positively with CMR-derived RV end-diastolic volume and negatively with echocardiography-derived LV and RV EF (all p < 0.05). Multiple linear regression identified sex and RV EF as significant correlates of log-transformed hs-cTnT levels. Increased hs-cTnT levels occur in 30% of female patients after TOF repair, and are associated with greater RV volumes and worse RV EF. PMID:26360613

  10. Evaluation of global and regional left ventricular function obtained by quantitative gated SPECT using {sup 99m}Tc-tetrofosmin for left ventricular dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Kazunobu; Nakajima, Tohru; Iseki, Harukazu; Abe, Sumihisa; Handa, Shunnosuke; Suzuki, Yutaka [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine

    2000-08-01

    The quantitative gated SPECT (QGS) software is able to calculate LV volumes and visualize LV wall motion and perfusion throughout the cardiac cycle using an automatic edge detection algorithm of the left ventricle. We evaluated the reliability of global and regional LV function assessment derived from QGS by comparing it with the results from left ventriculo-cineangiography (LVG). In 20 patients with left ventricular dysfunction who underwent ECG gated {sup 99m}Tc-tetrofosmin SPECT, the end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were calculated. The QGS-assessed regional wall motion was determined using the cinematic display. QGS-derived EDV, ESV and LVEF correlated well with those by LVG (p<0.001 for each). There was a good correlation between wall motion score (WMS) derived from the QGS and the LVG (r=0.40, p<0.05). In some patients with extensive myocardial infarction, there was a discrepancy in the regional wall motion results between QGS and LVG. The ECG-gated SPECT using QGS is useful to evaluate global and regional LV functions in left ventricular dysfunction. (author)

  11. Validation of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volume: comparison with cast-validated biplane cineventriculography

    International Nuclear Information System (INIS)

    Dell'Italia, L.J.; Starling, M.R.; Walsh, R.A.; Badke, F.R.; Lasher, J.C.; Blumhardt, R.

    1985-01-01

    To determine the accuracy of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volumes, the authors initially studied 14 postmortem human right ventricular casts by water displacement and biplane cineventriculography. Biplane cineventriculographic right ventricular cast volumes, calculated by a modification of Simpson's rule algorithm, correlated well with right ventricular cast volumes measured by water displacement (r = .97, y = 8 + 0.88x, SEE = 6 ml). Moreover, the mean volumes obtained by both methods were no different (73 +/- 28 vs 73 +/- 25 ml). Subsequently, they studied 16 patients by both biplane cineventriculography and equilibrium radionuclide angiography. The uncorrected radionuclide right ventricular volumes were calculated by normalizing background corrected end-diastolic and end-systolic counts from hand-drawn regions of interest obtained by phase analysis for cardiac cycles processed, frame rate, and blood sample counts. Attenuation correction was performed by a simple geometric method. The attenuation-corrected radionuclide right ventricular end-diastolic volumes correlated with the cineventriculographic end-diastolic volumes (r = .91, y = 3 + 0.92x, SEE = 27 ml). Similarly, the attenuation-corrected radionuclide right ventricular end-systolic volumes correlated with the cineventriculographic end-systolic volumes (r = .93, y = - 1 + 0.91x, SEE = 16 ml). Also, the mean attenuation-corrected radionuclide end-diastolic and end-systolic volumes were no different than the average cineventriculographic end-diastolic and end-systolic volumes (160 +/- 61 and 83 +/- 44 vs 170 +/- 61 and 86 +/- 43 ml, respectively)

  12. ω-3 Polyunsaturated fatty acids prevent pressure overload-induced ventricular dilation and decrease in mitochondrial enzymes despite no change in adiponectin

    Directory of Open Access Journals (Sweden)

    O'Shea Karen M

    2010-09-01

    Full Text Available Abstract Background Pathological left ventricular (LV hypertrophy frequently progresses to dilated heart failure with suppressed mitochondrial oxidative capacity. Dietary marine ω-3 polyunsaturated fatty acids (ω-3 PUFA up-regulate adiponectin and prevent LV dilation in rats subjected to pressure overload. This study 1 assessed the effects of ω-3 PUFA on LV dilation and down-regulation of mitochondrial enzymes in response to pressure overload; and 2 evaluated the role of adiponectin in mediating the effects of ω-3 PUFA in heart. Methods Wild type (WT and adiponectin-/- mice underwent transverse aortic constriction (TAC and were fed standard chow ± ω-3 PUFA for 6 weeks. At 6 weeks, echocardiography was performed to assess LV function, mice were terminated, and mitochondrial enzyme activities were evaluated. Results TAC induced similar pathological LV hypertrophy compared to sham mice in both strains on both diets. In WT mice TAC increased LV systolic and diastolic volumes and reduced mitochondrial enzyme activities, which were attenuated by ω-3 PUFA without increasing adiponectin. In contrast, adiponectin-/- mice displayed no increase in LV end diastolic and systolic volumes or decrease in mitochondrial enzymes with TAC, and did not respond to ω-3 PUFA. Conclusion These findings suggest ω-3 PUFA attenuates cardiac pathology in response to pressure overload independent of an elevation in adiponectin.

  13. Relation of N-Terminal Pro-B-Type Natriuretic Peptide and Left Ventricular Diastolic Function to Exercise Tolerance in Patients With Significant Valvular Heart Disease and Normal Left Ventricular Systolic Function.

    Science.gov (United States)

    Hwang, Ji-Won; Park, Sung-Ji; Cho, Eun Jeong; Kim, Eun Kyoung; Lee, Ga Yeon; Chang, Sung-A; Choi, Jin-Oh; Lee, Sang-Chol; Park, Seung Woo

    2017-06-01

    An association between N-terminal prohormone brain natriuretic peptide (NT-proBNP) and exercise tolerance in patients with valvular heart disease (VHD) has been suggested; however, there are few data available regarding this relation. The aim of this study is to evaluate the correlation between exercise tolerance and NT-proBNP in patients with asymptomatic or mildly symptomatic significant VHD and normal left ventricular ejection fraction (LV EF). A total of 96 patients with asymptomatic or mildly symptomatic VHD and normal LV EF (≥50%) underwent cardiopulmonary exercise echocardiography. NT-proBNP levels were determined at baseline and after exercise in 3 hours. Patients were divided in 2 groups based on lower (left atrial volume index before exercise, right ventricular systolic pressure before exercise, E velocity after exercise, and E/e' ratio after exercise varied significantly. In addition, peak VO 2 was inversely related to NT-proBNP before (r = -0.352, p left atrial volume index, E/e' ratio, and right ventricular systolic pressure before and after exercise. NT-proBNP after exercise was also directly related to the same parameters. NT-proBNP levels both before and after exercise were higher in the group with lower exercise tolerance. In conclusion, through the correlation among exercise tolerance, NT-proBNP, and parameters of diastolic dysfunction, we demonstrated that diastolic dysfunction and NT-proBNP could predict exercise tolerance in patients with significant VHD and normal LV EF. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function

    NARCIS (Netherlands)

    Coolen, Bram F.; Abdurrachim, Desiree; Motaal, Abdallah G.; Nicolay, Klaas; Prompers, Jeanine J.; Strijkers, Gustav J.

    2013-01-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered

  15. Independent prognostic value of left ventricular mass, diastolic function, and fasting plasma glucose

    DEFF Research Database (Denmark)

    Pareek, Manan; Nielsen, Mette Lundgren; Leósdóttir, Margrét

    2016-01-01

    OBJECTIVE: To explore the independent prognostic value of left ventricular (LV) mass, diastolic function, and fasting plasma glucose (FPG) for the prediction of incident cardiac events in a random population sample. DESIGN AND METHOD: 415 women and 999 men aged 56-79 years, included between 2002...

  16. Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography. Comparison with cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Belge, Benedicte; Pasquet, Agnes; Vanoverschelde, Jean-Louis J.; Coche, Emmanuel; Gerber, Bernhard L.

    2006-01-01

    Retrospective reconstruction of ECG-gated images at different parts of the cardiac cycle allows the assessment of cardiac function by multi-detector row CT (MDCT) at the time of non-invasive coronary imaging. We compared the accuracy of such measurements by MDCT to cine magnetic resonance (MR). Forty patients underwent the assessment of global and regional cardiac function by 16-slice MDCT and cine MR. Left ventricular (LV) end-diastolic and end-systolic volumes estimated by MDCT (134±51 and 67±56 ml) were similar to those by MR (137±57 and 70±60 ml, respectively; both P=NS) and strongly correlated (r=0.92 and r=0.95, respectively; both P<0.001). Consequently, LV ejection fractions by MDCT and MR were also similar (55±21 vs. 56±21%; P=NS) and highly correlated (r=0.95; P<0.001). Regional end-diastolic and end-systolic wall thicknesses by MDCT were highly correlated (r=0.84 and r=0.92, respectively; both P<0.001), but significantly lower than by MR (8.3±1.8 vs. 8.8±1.9 mm and 12.7±3.4 vs. 13.3±3.5 mm, respectively; both P<0.001). Values of regional wall thickening by MDCT and MR were similar (54±30 vs. 51±31%; P=NS) and also correlated well (r=0.91; P<0.001). Retrospectively gated MDCT can accurately estimate LV volumes, EF and regional LV wall thickening compared to cine MR. (orig.)

  17. Cardiovascular adaptations to 4 and 12 months of football or strength training in 65- to 75-year-old untrained men

    DEFF Research Database (Denmark)

    Schmidt, Jakob Friis; Hansen, Peter Riis; Rostgaard Andersen, Thomas

    2014-01-01

    The study examined the effects of 1 year of football or strength training on cardiovascular function in 65- to 75-year-old men. Twenty-six untrained men (age: 68.2 ± 3.2 years) were randomized to football training (FTG; n = 9), strength training (STG; n = 9), or control (CG; n = 8). In FTG, left...... ventricular (LV) internal diastolic diameter, end-diastolic volume, and mass index were 8%, 21%, and 18% higher (P 12 months, with no changes in STG and CG. After 12 months, LV ejection fraction was increased (P ... longitudinal two-dimensional strain by 8% and 6%, whereas right ventricular systolic function improved (P 12%, respectively, after 12 months...

  18. Impact Study of Electric Vehicle (EV) Integration on Low Voltage (LV) Grids

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cha, Seung-Tae; Nielsen, Arne Hejde

    2012-01-01

    the single line diagram (SLD) of the LV grid. The demand profiles of end-users are determined by the end-user yearly consumption and avreaged demand profiles of different customer types in Denmark. Five charging scenarios have been tested using the developed LV grid. The first two charging scenarios are dumb....... The two charging power levels are 1 phase 16 A and 3 phase 16 A. The loading of the power components and voltage profile are analyzed to quantify the impact of the charging scenarios and charging power levels on LV grids....

  19. Left atrial strain: a new parameter for assessment of left ventricular filling pressure.

    Science.gov (United States)

    Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio

    2016-01-01

    In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.

  20. Ambulatory monitoring of left ventricular function in patients with Parkinson`s disease and postural hypotension

    Energy Technology Data Exchange (ETDEWEB)

    Nappi, A. [Dept. of Nuclear Medicine, Univ. ``Federico II``, Naples (Italy); Cuocolo, A. [Dept. of Nuclear Medicine, Univ. ``Federico II``, Naples (Italy); Iazzetta, N. [Inst. of Internal Medicine and Metabolic Diseases, Univ. ``Federico II``, Naples (Italy); Ferrara, L.A. [Inst. of Internal Medicine and Metabolic Diseases, Univ. ``Federico II``, Naples (Italy); Marotta, T. [Inst. of Internal Medicine and Metabolic Diseases, Univ. ``Federico II``, Naples (Italy); Pace, L. [Dept. of Nuclear Medicine, Univ. ``Federico II``, Naples (Italy); Nicolai, E. [Dept. of Nuclear Medicine, Univ. ``Federico II``, Naples (Italy); De Michele, G. [Inst. of Neurological Sciences, Univ. ``Federico II``, Naples (Italy); Campanella, G. [Inst. of Neurological Sciences, Univ. ``Federico II``, Naples (Italy); Salvatore, M. [National Cancer Inst., Naples (Italy); Postiglione, A. [Inst. of Internal Medicine and Metabolic Diseases, Univ. ``Federico II``, Naples (Italy)

    1994-12-01

    Left ventricular (LV) function was continuously monitored using a radionuclide detector (VEST) after intravenous injection of 25 mCi technetium-99m labelled red blood cells in nine patients with Parkinson`s disease and postural hypotension (group 1) and ten patients with Parkinson`s disease but without postural hypotension (group 2). LV function and blood pressure were monitored in the supine position for 15 min (period A), upon changing posture from the supine to the upright position for 10 min (period B), and upon returning to the supine position for 10 min (period C). In group 1, the passage from period A to period B induced a significant decrease in end-diastolic volume, end-systolic volume and ejection fraction (all P<0.01). In group 2, ejection fraction increased (P<0.05) upon changing posture from the supine to the upright position. Ejection fraction (F=33, P<0.01), end-diastolic volume (F=9, P<0.05) and end-systolic volume (F=10, P<0.05) were significantly different between the two groups. In group 1, stroke volume, cardiac output and vascular peripheral resistance decreased from period A to period B (all P<0.001). In group 2, no changes in stroke volume, cardiac output and vascular peripheral resistance were observed from period A to period B. All parameters were similar in the two groups during the periods A and C. Upon changing posture from the supine to the upright position, patients with Parkinson`s disease and postural hypotension showed marked changes in parameters of LV function induced by vascular abnormalities. The results of this study may help to clarify the potential risk of sudden postural changes in such patients, which may cause fainting, syncope and increased risk of ischaemic coronary and cerebrovascular attacks and of lower limb fractures. (orig.)

  1. Increased dependence on slow filling for left ventricular diastolic filling in patients with coronary artery disease and a depressed systolic function

    International Nuclear Information System (INIS)

    Yamagishi, Takashi; Ozaki, Masaharu; Furutani, Yuhji; Yamamoto, Kouzo; Saeki, Atsushi; Satoh, Shinichi; Kusukawa, Reizo

    1990-01-01

    Contributions of rapid filling, slow filling and atrial systole to the left ventricular(LV) filling volume were analyzed with the use of radionuclide ventriculography at rest, both globally and regionally, in 34 patients with isolated disease of the left anterior descending coronary artery. The patients included 17 with a normal ejection fraction (EF≥50%; group 1) and 17 with a depressed EF (<50%; group 2), and the data were compared with those obtained from 13 normal subjects. A computer program subdivided the LV image into 4 regions, and time-activity curves were constructed globally and regionally by reverse-gating from the R wave. In both groups the contribution of rapid filling to the LV filling volume was decreased significantly in the affected septal and apical regions, and in the global left ventricle compared with that in normal subjects. In group 1, the contribution of atrial systole showed an increase in these affected regions and in the global left ventricle. In contrast, in group 2, the atrial contribution was not increased globally or regionally as much as was expected. However, the contribution of slow filling was either increased significantly or tended to increase in the affected regions and in the global left ventricle. There were negative correlations between the contribution of rapid filling and that of slow filling in the global left ventricle (r=-0.73, p<0.001) and in each of the septal, apical and lateral regions (r≥-0.60, p<0.001), which suggested that the contribution of slow filling as well as of atrial systole undergoes an increase as rapid filling is impaired. Thus, in patients with coronary artery disease, the left ventricle relies on slow filling as well as atrial systole to affect diastolic LV filling in the affected regions and in the global left ventricle in the presence of LV systolic dysfunction. (author)

  2. Worsening diastolic function is associated with elevated fasting plasma glucose and increased left ventricular mass in a supra-additive fashion in an elderly, healthy, Swedish population

    DEFF Research Database (Denmark)

    Pareek, Manan; Nielsen, Mette Lundgren; Gerke, Oke

    2015-01-01

    AIMS: To examine whether increasing fasting plasma glucose (FPG) levels were associated with worsening left ventricular (LV) diastolic function, independently of LV mass index (LVMI) in elderly, otherwise healthy subjects. METHODS AND RESULTS: We tested cross-sectional associations between...... echocardiographically determined averaged E/é ratio/diastolic function, LVMI, cardiovascular risk factors, and FPG categorized as normal (NFG), impaired (IFG), and new-onset diabetes mellitus (DM), in 483 men and 208 women aged 56-79years without overt cardiovascular disease, who received no cardiovascular, anti...

  3. Quantitative relationships between thallium-201 estimated myocardial infarct size and left ventricular function in the acute or convalescent phase of the first attack of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Hajime (Kagoshima Univ. (Japan). Faculty of Medicine); Ueda, Keiji; Sakai, Makoto (and others)

    1983-07-01

    Correlations between left ventricular (LV) function and infarct size estimated by computer-assisted thallium (Tl)-201 scintigraphy were studied in 16 patients in the acute or convalescent phase of the first attack of transmural myocardial infarction (MI). Tl-201 estimation of the infarct size was done using a ''corrected'' circumferential profile method, by which the total defect score could be obtained. The LV function was evaluated by radionuclide angiography, echocardiography and cardiac catheterization study. The following results were obtained: 1) A close inverse relationship was found between the defect score and the ejection fraction (r = -0.649, p < 0.01). 2) The linear correlation coefficient was 0.540 (p < 0.05) between the defect score and the pulmonary arterial end-diastolic pressure and -0.616 (p < 0.02) between the defect score and the stroke volume index. There was no significant correlation between the defect score and the cardiac index. 3) There was a linear correlation between the defect score and the LV end-diastolic dimension (r = -0.852, p < 0.001). However, there was no relation between the defect score and the left atrial dimension. When the LV indices were compared between the small (S) and the large (L) defect score group, the L defect group had faster heart rate, larger LV chamber size and the smaller stroke volume index than the S defect group. However, there was no significant difference in the cardiac index between these 2 groups. These results suggest that the LV dilatation in acute or convalescent phase of the first attack of transmural MI is an ominous sign because it was usually accompanied by large infarct size. The present study also indicates that LV dilatation accompanying a large infarct does not satisfactorily compensate for LV dysfunction by Frank-Starling mechanism.

  4. Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Borleffs, C.J.W.; Schalij, Martin J.; Wall, Ernst E. van der; Bax, Jeroen J.; Dibbets-Schneider, Petra; Hiel, Bernies van der; Younis, Imad Al

    2011-01-01

    The aim of the current study was to evaluate the relationship between the site of latest mechanical activation as assessed with gated myocardial perfusion SPECT (GMPS), left ventricular (LV) lead position and response to cardiac resynchronization therapy (CRT). The patient population consisted of consecutive patients with advanced heart failure in whom CRT was currently indicated. Before implantation, 2-D echocardiography and GMPS were performed. The echocardiography was performed to assess LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV) and LV ejection fraction (LVEF). The site of latest mechanical activation was assessed by phase analysis of GMPS studies and related to LV lead position on fluoroscopy. Echocardiography was repeated after 6 months of CRT. CRT response was defined as a decrease of ≥15% in LVESV. Enrolled in the study were 90 patients (72% men, 67±10 years) with advanced heart failure. In 52 patients (58%), the LV lead was positioned at the site of latest mechanical activation (concordant), and in 38 patients (42%) the LV lead was positioned outside the site of latest mechanical activation (discordant). CRT response was significantly more often documented in patients with a concordant LV lead position than in patients with a discordant LV lead position (79% vs. 26%, p<0.01). After 6 months, patients with a concordant LV lead position showed significant improvement in LVEF, LVESV and LVEDV (p<0.05), whereas patients with a discordant LV lead position showed no significant improvement in these variables. Patients with a concordant LV lead position showed significant improvement in LV volumes and LV systolic function, whereas patients with a discordant LV lead position showed no significant improvements. (orig.)

  5. Simple area-based measurement for multidetector computed tomography to predict left ventricular size

    International Nuclear Information System (INIS)

    Schlett, Christopher L.; Kwait, Dylan C.; Mahabadi, Amir A.; Hoffmann, Udo; Bamberg, Fabian; O'Donnell, Christopher J.; Fox, Caroline S.

    2010-01-01

    Measures of left ventricular (LV) mass and dimensions are independent predictors of morbidity and mortality. We determined whether an axial area-based method by computed tomography (CT) provides an accurate estimate of LV mass and volume. A total of 45 subjects (49% female, 56.0 ± 12 years) with a wide range of LV geometry underwent contrast-enhanced 64-slice CT. LV mass and volume were derived from 3D data. 2D images were analysed to determine LV area, the direct transverse cardiac diameter (dTCD) and the cardiothoracic ratio (CTR). Furthermore, feasibility was confirmed in 100 Framingham Offspring Cohort subjects. 2D measures of LV area, dTCD and CTR were 47.3 ± 8 cm 2 , 14.7 ± 1.5 cm and 0.54 ± 0.05, respectively. 3D-derived LV volume (end-diastolic) and mass were 148.9 ± 45 cm 3 and 124.2 ± 34 g, respectively. Excellent inter- and intra-observer agreement were shown for 2D LV area measurements (both intraclass correlation coefficients (ICC) = 0.99, p 0.27). Compared with traditionally used CTR, LV size can be accurately predicted based on a simple and highly reproducible axial LV area-based measurement. (orig.)

  6. Progression of Left Ventricular Dysfunction and Remodelling under Optimal Medical Therapy in CHF Patients: Role of Individual Genetic Background

    Directory of Open Access Journals (Sweden)

    Marzia Rigolli

    2011-01-01

    Full Text Available Background. Neurohormonal systems play an important role in chronic heart failure (CHF. Due to interindividual heterogeneity in the benefits of therapy, it may be hypothesized that polymorphisms of neurohormonal systems may affect left ventricular (LV remodelling and systolic function. We aimed to assess whether genetic background of maximally treated CHF patients predicts variations in LV systolic function and volumes. Methods and Results. We prospectively studied 131 CHF outpatients on optimal treatment for at least six months. Echocardiographic evaluations were performed at baseline and after 12 months. Genotype analysis for ACE I/D, β1adrenergic receptor (AR Arg389Gly, β2AR Arg16Gly, and β2AR Gln27Glu polymorphisms was performed. No differences in baseline characteristics were detected among subgroups. ACE II was a significant predictor of improvement of LV end-diastolic and end-systolic volume (=.003 and =.002, respectively but not of LV ejection fraction (LVEF; β1AR389 GlyGly was related to improvement of LVEF (=.02 and LV end-systolic volume (=.01. The predictive value of polymorphisms remained after adjustment for other clinically significant predictors (<.05 for all. Conclusions. ACE I/D and β1AR Arg389Gly polymorphisms are independent predictors of reverse remodeling and systolic function recovery in CHF patients under optimal treatment.

  7. EFFECT OF ISRADIPINE AND NIFEDIPINE ON DIASTOLIC FUNCTION IN PATIENTS WITH LEFT-VENTRICULAR DYSFUNCTION DUE TO CORONARY-ARTERY DISEASE - A RANDOMIZED, DOUBLE-BLIND, NUCLEAR, STETHOSCOPE STUDY

    NARCIS (Netherlands)

    VANDENTOREN, EW; DEVRIES, RJM; PORTEGIES, MCM; BLANKSMA, PK; VANGILST, WH; HILLEGE, HJ; VANVELDHUISEN, DJ; LIE, KI

    To elucidate the effect of isradipine and nifedipine on left ventricular (LV) systolic and diastolic function, each drug was given intravenously (i.v.) in equihypotensive doses to 10 patients accepted for coronary arteriography for stable angina pectoris. All 20 patients had LV ejection fraction

  8. Exercise training does not improve myocardial diastolic tissue velocities in Type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Nenonen Arja

    2007-09-01

    Full Text Available Abstract Background Myocardial diastolic tissue velocities are reduced already in newly onset Type 2 diabetes mellitus (T2D. Poor disease control may lead to left ventricular (LV systolic dysfunction and heart failure. The aim of this study was to assess the effects of exercise training on myocardial diastolic function in T2D patients without ischemic heart disease. Methods 48 men (52.3 ± 5.6 yrs with T2D were randomized to supervised training four times a week and standard therapy (E, or standard treatment alone (C for 12 months. Glycated hemoglobin (HbA1c, oxygen consumption (VO2max, and muscle strength (Sit-up were measured. Tissue Doppler Imaging (TDI was used to determine the average maximal mitral annular early (Ea and late (Aa diastolic as well as systolic (Sa velocities, systolic strain (ε and strain rate (έ from the septum, and an estimation of left ventricular end diastolic pressure (E/Ea. Results Exercise capacity (VO2max, E 32.0 to 34.7 vs. C 32.6 to 31.5 ml/kg/min, p = .001, muscle strength (E 12.7 to 18.3 times vs. C 14.6 to 14.7 times, p 1c (E 8.2 to 7.5% vs. C 8.0 to 8.4%, p = .006 improved significantly in the exercise group compared to the controls (ANOVA. Systolic blood pressure decreased in the E group (E 144 to 138 mmHg vs. C 146 to 144 mmHg, p = .04. Contrary to risk factor changes diastolic long axis relaxation did not improve significantly, early diastolic velocity Ea from 8.1 to 7.9 cm/s for the E group vs. C 7.4 to 7.8 cm/s (p = .85, ANOVA. Likewise, after 12 months the mitral annular systolic velocity, systolic strain and strain rate, as well as E/Ea were unchanged. Conclusion Exercise training improves endurance and muscle fitness in T2D, resulting in better glycemic control and reduced blood pressure. However, myocardial diastolic tissue velocities did not change significantly. Our data suggest that a much longer exercise intervention may be needed in order to reverse diastolic impairment in diabetics, if at all

  9. Sympathetic stimulation alters left ventricular relaxation and chamber size.

    Science.gov (United States)

    Burwash, I G; Morgan, D E; Koilpillai, C J; Blackmore, G L; Johnstone, D E; Armour, J A

    1993-01-01

    Alterations in left ventricular (LV) contractility, relaxation, and chamber dimensions induced by efferent sympathetic nerve stimulation were investigated in nine anesthetized open-chest dogs in sinus rhythm. Supramaximal stimulation of acutely decentralized left stellate ganglia augmented heart rate, LV systolic pressure, and rate of LV pressure rise (maximum +dP/dt, 1,809 +/- 191 to 6,304 +/- 725 mmHg/s) and fall (maximum -dP/dt, -2,392 +/- 230 to -4,458 +/- 482 mmHg/s). It also reduced the time constant of isovolumic relaxation, tau (36.5 +/- 4.8 to 14.9 +/- 1.1 ms). Simultaneous two-dimensional echocardiography recorded reductions in end-diastolic and end-systolic LV cross-sectional chamber areas (23 and 31%, respectively), an increase in area ejection fraction (32%), and increases in end-diastolic and end-systolic wall thicknesses (14 and 13%, respectively). End-systolic and end-diastolic wall stresses were unchanged by stellate ganglion stimulation (98 +/- 12 to 95 +/- 9 dyn x 10(3)/cm2; 6.4 +/- 2.4 to 2.4 +/- 0.3 dyn x 10(3)/cm2, respectively). Atrial pacing to similar heart rates did not alter monitored indexes of contractility. Dobutamine and isoproterenol induced changes similar to those resulting from sympathetic neuronal stimulation. These data indicate that when the efferent sympathetic nervous system increases left ventricular contractility and relaxation, concomitant reductions in systolic and diastolic dimensions of that chamber occur that are associated with increasing wall thickness such that LV wall stress changes are minimized.

  10. Assessment of left ventricular mass in sequential studies with cine MR imaging

    International Nuclear Information System (INIS)

    Tomei, E.; Semelka, R.; Wagner, S.; Mayo, J.; Chatterjee, K.; Parmley, W.W.; O'Sullivan, M.; Wolfe, C.L.; Caputo, G.; Higgins, C.B.

    1989-01-01

    The aim of this study was to measure left ventricular (LV) mass in 11 healthy volunteers, 10 patients with dilated cardiomyopathy, and eight patients with LV hypertrophy (LVH), using two sequential studies to compare the characteristics of LV mass in the same subject and in different clinical situations. All subjects underwent short- axis cine MR imaging at 1.5 T. Each subject had two separate studies: the healthy volunteers within 6 months and those with cardiac disease within 1 week. Measurements (both end- systolic and end-diastolic) included LV mass, LV mass index, and wall thickness. LV mass was substantially increased in both DCM and LVH. The interstudy variability for end- systolic and end-diastolic mass was 5.2% and 3.8%, respectively, for healthy volunteers, 5.2% and 4.0% for LVH, and 3.8% and 6.1% for DCM. The low variability indicates the reproducibility of this technique in sequential studies when no change is expected

  11. Improvement of exercise capacity and left ventricular diastolic function with metoprolol XL after acute myocardial infarction

    DEFF Research Database (Denmark)

    Poulsen, S H; Jensen, S E; Egstrup, K

    2000-01-01

    dysfunction after acute myocardial infarction were given metoprolol XL (n = 29) or placebo (n = 30). The effects of metoprolol XL on exercise capacity in relation to effects on LV diastolic filling were studied. Two-dimensional Doppler echocardiography and maximal symptom limited bicycle test were performed...

  12. Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation.

    Science.gov (United States)

    Garcia, M J; Smedira, N G; Greenberg, N L; Main, M; Firstenberg, M S; Odabashian, J; Thomas, J D

    2000-01-01

    To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.

  13. Closing the loop: modelling of heart failure progression from health to end-stage using a meta-analysis of left ventricular pressure-volume loops.

    Science.gov (United States)

    Warriner, David R; Brown, Alistair G; Varma, Susheel; Sheridan, Paul J; Lawford, Patricia; Hose, David R; Al-Mohammad, Abdallah; Shi, Yubing

    2014-01-01

    The American Heart Association (AHA)/American College of Cardiology (ACC) guidelines for the classification of heart failure (HF) are descriptive but lack precise and objective measures which would assist in categorising such patients. Our aim was two fold, firstly to demonstrate quantitatively the progression of HF through each stage using a meta-analysis of existing left ventricular (LV) pressure-volume (PV) loop data and secondly use the LV PV loop data to create stage specific HF models. A literature search yielded 31 papers with PV data, representing over 200 patients in different stages of HF. The raw pressure and volume data were extracted from the papers using a digitising software package and the means were calculated. The data demonstrated that, as HF progressed, stroke volume (SV), ejection fraction (EF%) decreased while LV volumes increased. A 2-element lumped parameter model was employed to model the mean loops and the error was calculated between the loops, demonstrating close fit between the loops. The only parameter that was consistently and statistically different across all the stages was the elastance (Emax). For the first time, the authors have created a visual and quantitative representation of the AHA/ACC stages of LVSD-HF, from normal to end-stage. The study demonstrates that robust, load-independent and reproducible parameters, such as elastance, can be used to categorise and model HF, complementing the existing classification. The modelled PV loops establish previously unknown physiological parameters for each AHA/ACC stage of LVSD-HF, such as LV elastance and highlight that it this parameter alone, in lumped parameter models, that determines the severity of HF. Such information will enable cardiovascular modellers with an interest in HF, to create more accurate models of the heart as it fails.

  14. Closing the loop: modelling of heart failure progression from health to end-stage using a meta-analysis of left ventricular pressure-volume loops.

    Directory of Open Access Journals (Sweden)

    David R Warriner

    Full Text Available INTRODUCTION: The American Heart Association (AHA/American College of Cardiology (ACC guidelines for the classification of heart failure (HF are descriptive but lack precise and objective measures which would assist in categorising such patients. Our aim was two fold, firstly to demonstrate quantitatively the progression of HF through each stage using a meta-analysis of existing left ventricular (LV pressure-volume (PV loop data and secondly use the LV PV loop data to create stage specific HF models. METHODS AND RESULTS: A literature search yielded 31 papers with PV data, representing over 200 patients in different stages of HF. The raw pressure and volume data were extracted from the papers using a digitising software package and the means were calculated. The data demonstrated that, as HF progressed, stroke volume (SV, ejection fraction (EF% decreased while LV volumes increased. A 2-element lumped parameter model was employed to model the mean loops and the error was calculated between the loops, demonstrating close fit between the loops. The only parameter that was consistently and statistically different across all the stages was the elastance (Emax. CONCLUSIONS: For the first time, the authors have created a visual and quantitative representation of the AHA/ACC stages of LVSD-HF, from normal to end-stage. The study demonstrates that robust, load-independent and reproducible parameters, such as elastance, can be used to categorise and model HF, complementing the existing classification. The modelled PV loops establish previously unknown physiological parameters for each AHA/ACC stage of LVSD-HF, such as LV elastance and highlight that it this parameter alone, in lumped parameter models, that determines the severity of HF. Such information will enable cardiovascular modellers with an interest in HF, to create more accurate models of the heart as it fails.

  15. Assessment of left ventricular function by gated cardiac blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1991-01-01

    To elucidate the usefulness of gated cardiac blood-pool single photon emission CT (SPECT) with Tc-99m for the evaluation of left ventricular (LV) global and regional functions, 18 patients with coronary artery disease were studied. Thirty-two gated projection images were obtained over 360-degree at 16 frames per cardiac cycle. As LV volume was calculated by integrating the numbers of voxels which constituted LV and multiplying by the volume of a single voxel (0.1143 ml), we performed phantom studies to determine the appropriate cut-off level to detect LV outline. These cut-off levels were affected by the background activity and organ volume itself. So we constructed Volume-Cut-Level-Curve at each background activity. In clinical studies, short axis images which constituted LV were selected and provisional LV volumes were calculated at the cut-off levels of 45, 50 and 55%. These volumes were plotted on the Volume-Cut-Level-Curve and the true cut-off levels were obtained to calculate LV end-diastolic or end-systolic volume (EDV, ESV). The cut-off levels were different at every patient and ED or ES. EDV, ESV and LV ejection fraction obtained by SPECT were correlatd well with those obtained by contrast ventriculography (LVG) (r=0.89, 0.94, 0.94 each, p<0.01). For the LV wall motion analysis, LVGs obtained at two projections were compared with SPECT or gated cardiac blood-pool planar imaging (Planar) in 5 segments. In addition to visual comparison, wall motion scores (WMS) based on the degree of wall motion abnormality were calculated in each segment. Correlation of WMS between LVG and SPECT (r=0.84) was significantly (p<0.01) superior to that between LVG and Planar (r=0.62). Especially in SPECT, wall motion analyses at septal and infero-posterior segments were superior to those in Planar. Although gated SPECT requires relatively long time to perform, it is a useful method to detect LV global and regional functions. (author)

  16. Diastolic effects of chronic digitalization in systolic heart failure.

    Science.gov (United States)

    Hassapoyannes, C A; Bergh, M E; Movahed, M R; Easterling, B M; Omoigui, N A

    1998-10-01

    The efficacy of short-term digitalization on exercise tolerance may, in part, reflect enhanced diastolic performance. However, cardiac glycosides can impair ventricular relaxation from cytosolic Ca++ overload. To detect any time-dependent adverse effect, we assessed the diastolic function after long-term use of digitalis in patients with mild to moderate systolic left ventricular failure. From a cohort of 80 patients who received long-term, randomized, double-blind treatment with digitalis versus placebo at the WJB Dorn Veterans Affairs Medical Center, 38 survivors were evaluated at the end of follow-up (mean 48.4 months) with evaluators blinded to treatment used. Each survivor underwent equilibrium scintigraphic and echocardiographic assessment of diastolic function. Peak and mean filling rates normalized with filling volume (FV), diastolic phase durations normalized with duration of diastole, and filling fractions were measured from the time-activity curve. The isovolumic relaxation period and ventricular dimensions were computed echocardiographically. By actual-treatment-received analysis, treated versus untreated patients manifested a trend toward longer isovolumic relaxation (80.76 ms vs 61.54 ms, P = .06) but a markedly lower peak rapid filling rate (6.39 FV/sec vs 10.56 FV/sec, P = .02) despite comparable loading conditions. In addition, treated patients exhibited a lower mean rate of rapid filling (2.75 FV/sec vs 3.78 FV/sec, P = .05) in the absence of a longer rapid filling duration. However, the end-diastolic ventricular dimension did not differ between the 2 groups. Similar results were obtained by intention-to-treat analysis. Importantly, the mortality rate from worsening heart failure in the inception cohort was lower in the digitalis group versus the placebo group (P = .05) with no difference in total cardiac or all-cause mortality. After long-term digitalization for systolic left ventricular failure, cross-sectional comparison with a control group

  17. Factors of Formation of Various Types of Left Ventricular Diastolic Filling in Adolescents with Myocardium Pathology

    Directory of Open Access Journals (Sweden)

    L.F. Bogmat

    2016-08-01

    of general peripheral vascular resistance and cardiac output, and geometric one includes left atrial diameter and the left ventricular end-diastolic size. Formation of left ventricular diastolic dysfunction type 3 is influenced by such components of the neurohormonal system, as renin and angiotensin-II, then the process subsequently includes peripheral vascular tone and a geometric factor in the form of left atrial diameter and left ventricular end-diastolic size. Thus, in the initial stages of left ventricular diastolic dysfunction in adolescents with myocardial pathology, a significant role is played by the sympathoadrenal system, peripheral vascular tone and left atrial function, and then sequentially the renin-angiotensin system is being involved, which causes an increase in myocardial stiffness and, as a result, the inclusion in the pathological process not only of the left atrium, but also the structure (end-diastolic volume and function of the left ventricle (stroke volume.

  18. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  19. Effect of obstructive sleep apnea on mitral valve tenting.

    Science.gov (United States)

    Pressman, Gregg S; Figueredo, Vincent M; Romero-Corral, Abel; Murali, Ganesan; Kotler, Morris N

    2012-04-01

    Obstructive apneas produce high negative intrathoracic pressure that imposes an afterload burden on the left ventricle. Such episodes might produce structural changes in the left ventricle over time. Doppler echocardiograms were obtained within 2 months of attended polysomnography. Patients were grouped according to apnea-hypopnea index (AHI): mild/no obstructive sleep apnea (OSA; AHI <15) and moderate/severe OSA (AHI ≥15). Mitral valve tenting height and area, left ventricular (LV) long and short axes, and LV end-diastolic volume were measured in addition to tissue Doppler parameters. Comparisons of measurements at baseline and follow-up between and within groups were obtained; correlations between absolute changes (Δ) in echocardiographic parameters were also performed. After a mean follow-up of 240 days mitral valve tenting height increased significantly (1.17 ± 0.12 to 1.28 ± 0.17 cm, p = 0.001) in moderate/severe OSA as did tenting area (2.30 ± 0.41 to 2.66 ± 0.60 cm(2), p = 0.0002); Δtenting height correlated with ΔLV end-diastolic volume (rho 0.43, p = 0.01) and Δtenting area (rho 0.35, p = 0.04). In patients with mild/no OSA there was no significant change in tenting height; there was a borderline significant increase in tenting area (2.20 ± 0.44 to 2.31 ± 0.43 cm(2), p = 0.05). Septal tissue Doppler early diastolic wave decreased (8.04 ± 2.49 to 7.10 ± 1.83 cm/s, p = 0.005) in subjects with moderate/severe OSA but not in in those with mild/no OSA. In conclusion, in patients with moderate/severe OSA, mitral valve tenting height and tenting area increase significantly over time. This appears to be related, at least in part, to changes in LV geometry. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Reproducibility of peak filling and peak emptying rate determined by cardiovascular magnetic resonance imaging for assessment of biventricular systolic and diastolic dysfunction in patients with pulmonary arterial hypertension

    DEFF Research Database (Denmark)

    Göransson, Christoffer; Vejlstrup, Niels; Carlsen, Jørn

    2018-01-01

    Right ventricular (RV) and left ventricular (LV) diastolic stiffness may be independent contributors to disease progression in pulmonary arterial hypertension (PAH). The aims of this study are to assess reproducibility of peak emptying rate (PER) and early diastolic peak filling rate (PFR) for both...

  1. Dietary therapy in heart failure with preserved ejection fraction and/or left ventricular diastolic dysfunction in patients with metabolic syndrome.

    Science.gov (United States)

    von Bibra, Helene; Ströhle, Alexander; St John Sutton, Martin; Worm, Nicolai

    2017-05-01

    Heart failure is an ongoing epidemic of left ventricular (LV) dilatation and/or dysfunction due to the increasing prevalence of predisposing risk factors such as age, physical inactivity, (abdominal) obesity, and type-2-diabetes. Approximately half of these patients have diastolic heart failure (HFpEF). The prognosis of HFpEF is comparable to that of systolic heart failure, but without any known effective treatment. A biomathematically corrected diagnostic approach is presented that quantifies diastolic dysfunction via the predominant age dependency of LV diastolic function and unmasks (metabolic) risk factors, that are independent of age and, therefore, potential targets for therapy. Patients with HFpEF have reduced cardiac energy reserve that is frequently caused by insulin resistance. Consequently, HFpEF and/or LV diastolic dysfunction may be regarded as a cardiac manifestation of the metabolic syndrome (MetS). Accordingly, a causal therapy for metabolically induced dysfunction aims at normalizing insulin sensitivity by improving postprandial glucose and lipid metabolism. The respective treatments include 1) weight loss induced by dietary energy restriction that is often not sustained long-term and 2) independent of weight loss, focus on carbohydrate modification in exchange for an increase in protein and fat, ideally combined with an aerobic exercise program. Hence, beneficial effects of different macronutrient compositions in the dietary therapy of the underlying MetS are discussed together with the most recently available publications and meta-analyses. Modulation/restriction of carbohydrate intake normalizes postprandial hyperglycemic and insulinemic peaks and has been shown to improve all manifestations of the MetS and also to reduce cardiovascular risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Frequency-dependent left ventricular performance in women and men.

    Science.gov (United States)

    Wainstein, Rodrigo V; Sasson, Zion; Mak, Susanna

    2012-06-01

    We aimed to determine whether sex differences in humans extend to the dynamic response of the left ventricular (LV) chamber to changes in heart rate (HR). Several observations suggest sex influences LV structure and function in health; moreover, this physiology is also affected in a sex-specific manner by aging. Eight postmenopausal women and eight similarly aged men underwent a cardiac catheterization-based study for force-interval relationships of the LV. HR was controlled by right atrial (RA) pacing, and LV +dP/dt(max) and volume were assessed by micromanometer-tipped catheter and Doppler echocardiography, respectively. Analysis of approximated LV pressure-volume relationships was performed using a time-varying model of elastance. External stroke work was also calculated. The relationship between HR and LV +dP/dt(max) was expressed as LV +dP/dt(max) = b + mHR. The slope (m) of the relationship was steeper in women compared with men (11.8 ± 4.0 vs. 6.1 ± 4.1 mmHg·s(-1)·beats(-1)·min(-1), P = 0.01). The greater increase in contractility in women was reproducibly observed after normalizing LV +dP/dt(max) to LV end-diastolic volume (LVVed) or by measuring end-systolic elastance. LVVed and stroke volume decreased more in women. Thus, despite greater increases in contractility, HR was associated with a lesser rise in cardiac output and a steeper fall in external stroke work in women. Compared with men, women exhibit greater inotropic responses to incremental RA pacing, which occurs at the same time as a steeper decline in external stroke work. In older adults, we observed sexual dimorphism in determinants of LV mechanical performance.

  3. Predicting device failure after percutaneous repair of functional mitral regurgitation in advanced heart failure: Implications for patient selection.

    Science.gov (United States)

    Stolfo, Davide; De Luca, Antonio; Morea, Gaetano; Merlo, Marco; Vitrella, Giancarlo; Caiffa, Thomas; Barbati, Giulia; Rakar, Serena; Korcova, Renata; Perkan, Andrea; Pinamonti, Bruno; Pappalardo, Aniello; Berardini, Alessandra; Biagini, Elena; Saia, Francesco; Grigioni, Francesco; Rapezzi, Claudio; Sinagra, Gianfranco

    2018-04-15

    Patients with heart failure (HF) and severe symptomatic functional mitral regurgitation (FMR) may benefit from MitraClip implantation. With increasing numbers of patients being treated the success of procedure becomes a key issue. We sought to investigate the pre-procedural predictors of device failure in patients with advanced HF treated with MitraClip. From April 2012 to November 2016, 76 patients with poor functional class (NYHA class III-IV) and severe left ventricular (LV) remodeling underwent MitraClip implantation at University Hospitals of Trieste and Bologna (Italy). Device failure was assessed according to MVARC criteria. Patients were subsequently followed to additionally assess the patient success after 12months. Mean age was 67±12years, the mean Log-EuroSCORE was 23.4±16.5%, and the mean LV end-diastolic volume index and ejection fraction (EF) were 112±33ml/m 2 and 30.6±8.9%, respectively. At short-term evaluation, device failure was observed in 22 (29%) patients. Univariate predictors of device failure were LVEF, LV and left atrial volumes and anteroposterior mitral annulus diameter. Annulus dimension (OR 1.153, 95% CI 1.002-1.327, p=0.043) and LV end-diastolic volume (OR 1.024, 95% CI 1.000-1.049, p=0.049) were the only variables independently associated with the risk of device failure at the multivariate model. Pre-procedural anteroposterior mitral annulus diameter accurately predicted the risk of device failure after MitraClip in the setting of advanced HF. Its assessment might aid the selection of the best candidates to percutaneous correction of FMR. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Left-ventricular reduction surgery: pre- and postoperative evaluation by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Wiese, T.H.; Lembcke, A.; Hamm, B.; Hotz, H.; Konertz, W.; Borges, A.C.; Baumann, G.

    2001-01-01

    Aim: To evaluate the role of cine magnetic resonance imaging (MRI) in the preoperative assessment and postoperative follow-up of patients undergoing left ventricular (LV) reduction surgery. Patients and Methods: 6 patients with cardiomegaly were examined on a 1.5 T MR imager before and after LV reduction surgery. The heart was imaged along the short and long axes using a breath-hold ECG-triggered cine gradient-echo sequence for assessing ventricular and valvular morphology and function and performing volumetry (end-diastolic and end-systolic volumes, ejection fraction). Results: Postoperatively, the mean ejection fraction increased from 21.7% to 33.4% and the enddiastolic and end-systolic left ventricular volumes decreased in all patients (304.0 and 252.5 ml before to 205.0 and 141.9 ml after surgery). Mean myocardial mass decreased slightly from 283.8 g to 242.7 g. Differences were significant for all parameters (p [de

  5. Carotid Artery End-Diastolic Velocity and Future Cerebro-Cardiovascular Events in Asymptomatic High Risk Patients.

    Science.gov (United States)

    Chung, Hyemoon; Jung, Young Hak; Kim, Ki-Hyun; Kim, Jong-Youn; Min, Pil-Ki; Yoon, Young Won; Lee, Byoung Kwon; Hong, Bum-Kee; Rim, Se-Joong; Kwon, Hyuck Moon; Choi, Eui-Young

    2016-01-01

    Prognostic value of additional carotid Doppler evaluations to carotid intima-media thickness (IMT) and plaque has not been completely evaluated. A total of 1119 patients with risk factors for, but without, overt coronary artery disease (CAD), who underwent both carotid ultrasound and Doppler examination were included in the present study. Parameters of interest included peak systolic and end-diastolic velocities, resistive indices of the carotid arteries, IMT, and plaque measurements. The primary end-point was all-cause cerebro-cardiovascular events (CVEs) including acute myocardial infarction, coronary revascularization therapy, heart failure admission, stroke, and cardiovascular death. Model 1 covariates comprised age and sex; Model 2 also included hypertension, diabetes and smoking; Model 3 also had use of aspirin and statin; and Model 4 also included IMT and plaque. The mean follow-up duration was 1386±461 days and the mean age of the study population was 60±12 years. Amongst 1119 participants, 43% were women, 57% had a history of hypertension, and 23% had diabetes. During follow-up, 6.6% of patients experienced CVEs. Among carotid Doppler parameters, average common carotid artery end-diastolic velocity was the independent predictor for future CVEs after adjustments for all models variables (HR 0.95 per cm/s, 95% confident interval 0.91-0.99, p=0.034 in Model 4) and significantly increased the predictive value of Model 4 (global χ(2)=59.0 vs. 62.8, p=0.029). Carotid Doppler measurements in addition to IMT and plaque evaluation are independently associated with future CVEs in asymptomatic patients at risk for CAD.

  6. Effect of streptozotocin-induced diabetes on left ventricular function in adult rats: an in vivo Pinhole Gated SPECT study

    Directory of Open Access Journals (Sweden)

    Weytjens Caroline

    2007-10-01

    Full Text Available Abstract Background Recent studies have suggested that diabetes mellitus (DM may cause left ventricular (LV dysfunction directly resulting in increased susceptibility to heart failure. Using pinhole collimators and advances in data processing, gated SPECT was recently adapted to image the rat heart. The present study was aimed to assess this new imaging technique for quantifying LV function and remodeling from the Streptozotocin (STZ rat model compared to controls. Methods Twenty one rats were randomly assigned to control or diabetic group. Six months after the induction of diabetes by STZ, Pinhole 99 m Tc-sestamibi gated SPECT was performed for determining rat LV volumes and function. Post-mortem histopathologic analysis was performed to evaluate the determinant of LV remodeling in this model. Results After six months, the normalized to body weight LV End-systolic volume was significantly different in diabetic rats compared to controls (0.46 ± 0.02 vs 0.33 ± 0.03 μL/g; p = 0.01. The normalized LV End-diastolic volume was also different in both groups (1.51 ± 0.03 vs 0.88 ± 0.05 μL/g; p = 0.001 and the normalized stroke volume was significantly higher in STZ-rats (1.05 ± 0.02 vs 0.54 ± 0.06 μL/g; p = 0.001. The muscular fibers were thinner at histology in the diabetic rats (0.44 ± 0.07 vs 0.32 ± 0.06 AU; p = 0.01. Conclusion Pinhole 99 m Tc-sestamibi gated SPECT can successfully be applied for the evaluation of cardiac function and remodeling in STZ-induced diabetic rats. In this model, LV volumes were significantly changed compared to a control population, leading to a LV dysfunction. These findings were consistent with the histopathological abnormalities. Finally, these data further suggest the presence of diabetes cardiomyopathy.

  7. Effect of well-controlled gestational diabetes on left ventricular diastolic dysfunction in neonates.

    Science.gov (United States)

    Ghandi, Yazdan; Habibi, Danial; Nasri, Khadijeh; Alinejad, Saeed; Taherahmad, Hassan; Arjmand Shabestari, Ali; Nematinejad, Ali

    2018-06-17

    There are some evidences supporting the relation between gestational diabetes mellitus (GDM) and diastolic dysfunction. The aim of our study was to investigate the effect of well-controlled GDM on morphological and functional myocardium. We designed a prospective cross-sectional study to evaluate left ventricular (LV) diastolic function of 60 neonates born from mothers with well-controlled GDM (case group) on days of 3-5 after birth. The infants of diabetic mothers (IDM) group were divided into two groups: diabetic mothers treated only with diet (class A) and group of mothers on medical therapy by insulin or metformin (class B). Traditional echocardiography and pulsed-wave Doppler (PWD), tissue Doppler imaging (TDI) were performed for all the neonates. The study group consisted of 60 neonates as males (M) = 32, (0.53%) and females (F) = 28, (0.46%). Using M-mode echocardiography, interventricular septum thickness (IVS), and LV mass were significantly higher in IDM than control group (p = .0001). The PWD showed both a significantly more peak mitral flow at early diastolic wave (E) and an early filling deceleration time (E-DT) (p = .0001). Tissue Doppler echocardiography parameters A' (cm/s) (p = .0001), E' (cm/s) (p = .002), and E'/A' ratio (p = .0001), left ventricular myocardial performance index (LVMPI), and isovolumetric relaxation time (IVRT) were outstandingly different between the two groups (p = .0001, respectively). Evaluating the GDM group mothers of class A and class B, no significant difference was noted in PWD or TDI parameters compared with the healthy ones. It seems that neonates of mothers with well-controlled GDM are still at increased risk of cardiac hypertrophy, subclinical diastolic dysfunction, and impaired left ventricular relaxation. This can be interpreted that focusing only on glycemic control is not enough to prevent cardiac dysfunction.

  8. Gestational changes in left ventricular myocardial contractile function: new insights from two-dimensional speckle tracking echocardiography.

    Science.gov (United States)

    Sengupta, Shantanu P; Bansal, Manish; Hofstra, Leonard; Sengupta, Partho P; Narula, Jagat

    2017-01-01

    The goal of this study was to evaluate the impact of pregnancy and labor on left ventricular (LV) myocardial mechanics using speckle tracking echocardiography (STE). Pregnancy is characterized by profound hormonal and hemodynamic alterations that directly or indirectly influence cardiac structure and function. However, the impact of these changes on left ventricular (LV) myocardial contractile function has not been fully elucidated. In this prospective, longitudinal study, 35 pregnant women underwent serial clinical and echocardiographic evaluation during each trimester and at labor. Two dimensional STE was performed to measure global LV longitudinal, circumferential and radial strain (GLS, GCS and GRS, respectively). Similar data obtained from 20 nulliparous, age-matched women were used as control. All strain values during pregnancy were adjusted for age and hemodynamic parameters. There was a progressive increase in heart rate, systolic and diastolic blood pressure, cardiac output and LV stroke-work during pregnancy. LV end-diastolic and end-systolic volumes also increased progressively but LV ejection fraction remained unaltered, except for slight reduction during the second trimester. Compared to the controls, GLS and GCS were reduced in the first trimester itself (GLS -22.39 ± 5.43 % vs. -18.66 ± 0.64 %, P 0.0002; GCS -20.84 ± 3.20 vs. -17.88 ± 0.09, P counterbalancing changes in the myocardial mechanics. LV longitudinal and circumferential strain are reduced whereas radial strain is increased. These counterbalancing changes serve to maintain overall LV ejection performance within a normal range and enable the maternal heart to meet the hemodynamic demands of pregnancy and labor.

  9. Evaluation of right ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Stubgaard, M; Thomsen, C

    1988-01-01

    stroke volume was calculated as the difference between end-diastolic and end-systolic volume and compared to left ventricular stroke volume and to stroke volume determined simultaneously by a classical indicator dilution technique. There was good agreement between right ventricular stroke volume......Right ventricular volumes were determined in 12 patients with different levels of right and left ventricular function by magnetic resonance imaging (MRI) using an ECG gated multisection technique in planes perpendicular to the diastolic position of the interventricular septum. Right ventricular...... determined by MRI and by the indicator dilution method and between right and left ventricular stroke volume determined by MRI. Thus, MRI gives reliable values not only for left ventricular volumes, but also for right ventricular volumes. By MRI it is possible to obtain volumes from both ventricles...

  10. Effects of Combined Milrinone and Levosimendan Treatment on Systolic and Diastolic Function During Postischemic Myocardial Dysfunction in a Porcine Model.

    Science.gov (United States)

    Axelsson, Birger; Häggmark, Sören; Svenmarker, Staffan; Johansson, Göran; Gupta, Anil; Tydén, Hans; Wouters, Patrick; Haney, Michael

    2016-09-01

    It is not known whether there are positive or negative interactions on ventricular function when a calcium-sensitizing inotrope is added to a phosphodiesterase inhibitor in the clinical setting of acute left ventricular (LV) dysfunction. We hypothesized that when levosimendan is added to milrinone treatment, there will be synergetic inotropic and lusitropic effects. This was tested in an anesthetized porcine postischemic global LV injury model, where ventricular pressures and volumes (conductance volumetry) were measured. A global ischemic injury was induced by repetitive left main stem coronary artery occlusions. Load-independent indices of LV function were assessed before and after ventricular injury, after milrinone treatment, and finally after addition of levosimendan to the milrinone treatment. Nonparametric, within-group comparisons were made. The protocol was completed in 12 pigs, 7 of which received the inotrope treatment and 5 of which served as controls. Milrinone led to positive lusitropic effects seen by improvement in tau after myocardial stunning. The addition of levosimendan to milrinone further increased lusitropic state. The latter effect could however not be attributed solely to levosimendan, since lusitropic state also improved spontaneously in time-matched controls at the same rate during the corresponding period. When levosimendan was added to milrinone infusion, there was no increase in systolic function (preload recruitable stroke work) compared to milrinone treatment alone. We conclude that in this model of postischemic LV dysfunction, there appears to be no clear improvement in systolic or diastolic function after addition of levosimendan to established milrinone treatment but also no negative effects of levosimendan in this context. © The Author(s) 2016.

  11. Measurement of right ventricular volumes using 131I-MAA

    International Nuclear Information System (INIS)

    Sekimoto, T.; Grover, R.F.

    1975-01-01

    A method is presented for determining the right ventricular residual ratio, that is, the ratio of the end-systolic volume to the end-diastolic volume during each cardiac cycle. 131 I-MAA was injected as a bolus into the right ventricle, and the ratio of isotope remaining in the chamber during the succeeding cardiac cycles was determined with a collimated scintillation counter placed over the right ventricle. Since the counter detected the radioactivity from the entire right ventricular cavity, potential errors from incomplete mixing were minimized. The washout curve from the ventricle was distorted somewhat by the accumulation of isotope in intervening lung tissue. This distortion was eliminated by subtracting the build-up curve of radioactivity in the lung recorded simultaneously with a second scintillation counter positioned over the lateral chest wall. In 14 dogs anesthetized with chloralose, the right ventricular residual ratio was relatively constant at 40.4 +- 3.1 per cent. Duplicate measurements differed by less than 3 percent indicating the good reproducibility of the method. Right ventricular stroke volume was determined from cardiac output (dye dilution) and heart rate. With this and the simultaneously determined residual ratio ( 131 I-MAA), end-diastolic volume could be calculated. Stroke volume and stroke work were highly correlated with end-diastolic volume, in keeping with the Frank-Starling mechanism. (U.S.)

  12. Reproducibility of small animal cine and scar cardiac magnetic resonance imaging using a clinical 3.0 tesla system

    International Nuclear Information System (INIS)

    Manka, Robert; Jahnke, Cosima; Hucko, Thomas; Dietrich, Thore; Gebker, Rolf; Schnackenburg, Bernhard; Graf, Kristof; Paetsch, Ingo

    2013-01-01

    To evaluate the inter-study, inter-reader and intra-reader reproducibility of cardiac cine and scar imaging in rats using a clinical 3.0 Tesla magnetic resonance (MR) system. Thirty-three adult rats (Sprague–Dawley) were imaged 24 hours after surgical occlusion of the left anterior descending coronary artery using a 3.0 Tesla clinical MR scanner (Philips Healthcare, Best, The Netherlands) equipped with a dedicated 70 mm solenoid receive-only coil. Left-ventricular (LV) volumes, mass, ejection fraction and amount of myocardial scar tissue were measured. Intra-and inter-observer reproducibility was assessed in all animals. In addition, repeat MR exams were performed in 6 randomly chosen rats within 24 hours to assess inter-study reproducibility. The MR imaging protocol was successfully completed in 32 (97%) animals. Bland-Altman analysis demonstrated high intra-reader reproducibility (mean bias%: LV end-diastolic volume (LVEDV), -1.7%; LV end-systolic volume (LVESV), -2.2%; LV ejection fraction (LVEF), 1.0%; LV mass, -2.7%; and scar mass, -1.2%) and high inter-reader reproducibility (mean bias%: LVEDV, 3.3%; LVESV, 6.2%; LVEF, -4.8%; LV mass, -1.9%; and scar mass, -1.8%). In addition, a high inter-study reproducibility was found (mean bias%: LVEDV, 0.1%; LVESV, -1.8%; LVEF, 1.0%; LV mass, -4.6%; and scar mass, -6.2%). Cardiac MR imaging of rats yielded highly reproducible measurements of cardiac volumes/function and myocardial infarct size on a clinical 3.0 Tesla MR scanner system. Consequently, more widely available high field clinical MR scanners can be employed for small animal imaging of the heart e.g. when aiming at serial assessments during therapeutic intervention studies

  13. Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function-Current Clinical Applications and Literature Review Update.

    Science.gov (United States)

    Velasco, Omar; Beckett, Morgan Q; James, Aaron W; Loehr, Megan N; Lewis, Taylor G; Hassan, Tahmin; Janardhanan, Rajesh

    2017-01-01

    Our review of real-time three-dimensional echocardiography (RT3DE) discusses the diagnostic utility of RT3DE and provides a comparison with two-dimensional echocardiography (2DE) in clinical cardiology. A Pubmed literature search on RT3DE was performed using the following key words: transthoracic, two-dimensional, three-dimensional, real-time, and left ventricular (LV) function. Articles included perspective clinical studies and meta-analyses in the English language, and focused on the role of RT3DE in human subjects. Application of RT3DE includes analysis of the pericardium, right ventricular (RV) and LV cavities, wall motion, valvular disease, great vessels, congenital anomalies, and traumatic injury, such as myocardial contusion. RT3DE, through a transthoracic echocardiography (TTE), allows for increasingly accurate volume and valve motion assessment, estimated LV ejection fraction, and volume measurements. Chamber motion and LV mass approximation have been more accurately evaluated by RT3DE by improved inclusion of the third dimension and quantification of volumetric movement. Moreover, RT3DE was shown to have no statistical significance when comparing the ejection fractions of RT3DE to cardiac magnetic resonance (CMR). Analysis of RT3DE data sets of the LV endocardial exterior allows for the volume to be directly quantified for specific phases of the cardiac cycle, ranging from end systole to end diastole, eliminating error from wall motion abnormalities and asymmetrical left ventricles. RT3DE through TTE measures cardiac function with superior diagnostic accuracy in predicting LV mass, systolic function, along with LV and RV volume when compared with 2DE with comparable results to CMR.

  14. Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function—Current Clinical Applications and Literature Review Update

    Directory of Open Access Journals (Sweden)

    Morgan Q. Beckett

    2017-03-01

    Full Text Available Our review of real-time three-dimensional echocardiography (RT3DE discusses the diagnostic utility of RT3DE and provides a comparison with two-dimensional echocardiography (2DE in clinical cardiology. A Pubmed literature search on RT3DE was performed using the following key words: transthoracic, two-dimensional, three-dimensional, real-time, and left ventricular (LV function. Articles included perspective clinical studies and meta-analyses in the English language, and focused on the role of RT3DE in human subjects. Application of RT3DE includes analysis of the pericardium, right ventricular (RV and LV cavities, wall motion, valvular disease, great vessels, congenital anomalies, and traumatic injury, such as myocardial contusion. RT3DE, through a transthoracic echocardiography (TTE, allows for increasingly accurate volume and valve motion assessment, estimated LV ejection fraction, and volume measurements. Chamber motion and LV mass approximation have been more accurately evaluated by RT3DE by improved inclusion of the third dimension and quantification of volumetric movement. Moreover, RT3DE was shown to have no statistical significance when comparing the ejection fractions of RT3DE to cardiac magnetic resonance (CMR. Analysis of RT3DE data sets of the LV endocardial exterior allows for the volume to be directly quantified for specific phases of the cardiac cycle, ranging from end systole to end diastole, eliminating error from wall motion abnormalities and asymmetrical left ventricles. RT3DE through TTE measures cardiac function with superior diagnostic accuracy in predicting LV mass, systolic function, along with LV and RV volume when compared with 2DE with comparable results to CMR.

  15. Impact of endothelial dysfunction on left ventricular remodeling after successful primary coronary angioplasty for acute myocardial infarction. Analysis by quantitative ECG-gated SPECT

    International Nuclear Information System (INIS)

    Matsuo, Shinro; Nakae, Ichiro; Matsumoto, Tetsuya; Horie, Minoru

    2006-01-01

    We hypothesized that endothelial cell integrity in the risk area would influence left ventricular remodeling after acute myocardial infarction. Twenty patients (61±8 y.o.) with acute myocardial infarction underwent 99m Tc-tetrofosmin imaging in the sub-acute phase and three months after successful primary angioplasty due to myocardial infarction. All patients were administered angiotensin-converting enzyme inhibitor after revascularization. Cardiac scintigraphies with quantitative gated SPECT were performed at the sub-acute stage and again 3 months after revascularization to evaluate left ventricular (LV) remodeling. The left ventricular ejection fraction (EF) and end-systolic and end-diastolic volume (ESV, EDV) were determined using a quantitative gated SPECT (QGS) program. Three months after myocardial infarction, all patients underwent cardiac catheterization examination with coronary endothelial function testing. Bradykinin (BK) (0.2, 0.6, 2.0 μg/min) was administered via the left coronary artery in a stepwise manner. Coronary blood flow was evaluated by Doppler flow velocity measurement. Patients were divided into two groups by BK-response: a preserved endothelial function group (n=10) and endothelial dysfunction group (n=10). At baseline, both global function and LV systolic and diastolic volumes were similar in both groups. However, LV ejection fraction was significantly improved in the preserved-endothelial function group, compared with that in the endothelial dysfunction group (42±10% to 48±9%, versus 41±4% to 42±13%, p<0.05). LV volumes progressively increased in the endothelial dysfunction group compared to the preserved-endothelial function group (123±45 ml to 128±43 ml, versus 111±47 ml to 109±49 ml, p<0.05). In re-perfused acute myocardial infarction, endothelial function within the risk area plays an important role with left ventricular remodeling after myocardial infarction. (author)

  16. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, Naples (Italy); Duilio, Carlo; Santomauro, Maurizio [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2005-09-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction {>=}50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  17. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    International Nuclear Information System (INIS)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto; Duilio, Carlo; Santomauro, Maurizio

    2005-01-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction ≥50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  18. Serum levels of advanced glycation end products are associated with left ventricular diastolic function in patients with type 1 diabetes

    DEFF Research Database (Denmark)

    Berg, T J; Snorgaard, O; Faber, J

    1999-01-01

    Impairment of left ventricular diastolic function, possibly caused by increased collagen cross-linking of the cardiac muscle, is common in patients with type 1 diabetes even without coronary artery disease. Advanced glycation end products (AGEs) cross-link tissue collagen and are found within...

  19. Cardiothoracic ratio on chest radiograph in pediatric heart disease: How does it correlate with heart volumes at magnetic resonance imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Grotenhuis, Heynric B. [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); Zhou, Cheng; Isaac, Kathryn V. [The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Tomlinson, George [University of Toronto, Department of Medicine, Toronto General Hospital and Mt. Sinai Hospital, Toronto (Canada); Seed, Mike; Grosse-Wortmann, Lars; Yoo, Shi-Joon [The University of Toronto, Division of Cardiology, Department of Paediatrics, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto (Canada); The University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada)

    2015-10-15

    The cardiothoracic ratio by chest radiograph is widely used as a marker of cardiac size. The purpose of this study is to correlate cardiothoracic ratio and cardiac volumes as measured by cardiovascular magnetic resonance (MR) in common structural and myopathic heart disease with increased cardiac size due to volume overload or hypertrophy. A retrospective single center study was performed in all patients between 2007 and 2013 with repaired tetralogy of Fallot (TOF), aortic regurgitation, isolated left-to-right shunt and hypertrophic cardiomyopathy (HCM) who underwent cardiovascular MR and chest radiograph within 6 months of each other. Cardiothoracic ratios by chest radiograph (frontal and lateral) were compared to cardiac volumes (indexed for body surface area) by cardiovascular MR. One hundred twenty-seven patients (mean age: 11.2 ± 5.5 years) were included in this study (76 with TOF, 23 with isolated left-to-right shunt, 16 with aortic regurgitation and 12 with HCM). Frontal cardiothoracic ratio of all groups correlated with indexed right ventricular (RV) end-diastolic volume (EDVI) (r = 0.40, P < 0.01) and indexed total heart volume (THVI) (r = 0.27, P < 0.01). In TOF patients, frontal cardiothoracic ratio correlated with RVEDVI (r = 0.34, P < 0.01; coefficient of variation = 27.6%), indexed RV end-systolic volume (ESVI) (r = 0.44, P < 0.01; coefficient of variation = 33.3%) and THVI (r = 0.35, P < 0.01; coefficient of variation = 19.6%), although RV volumes and THVI showed widespread variation given the high coefficients of variation. In patients with aortic regurgitation, frontal cardiothoracic ratio correlated with left ventricular (LV) EDVI (r = 0.50, P = 0.047), but not with THVI and aortic regurgitant fraction, and widespread variation for LV EDVI (coefficient of variation = 19.2%), LV ESVI (coefficient of variation = 32.5%) and THVI (coefficient of variation = 13.6%) was also observed. Frontal cardiothoracic ratio was not correlated with cardiac volumes

  20. Effects of rapid digitalization on total and regional myocardial performance in patients with coronary artery disease.

    Science.gov (United States)

    Ferlinz, J; DelVicario, M; Aronow, W S

    1978-09-01

    In order to evaluate the effects of rapid digitalization on LV volumes, ejection fraction, and asynergy, 21 patients without heart failure were studied with a combination of hemodynamic and angiographic techniques before and after administration of intravenous ouabain (0.007 mg./Kg.). Seven patients had no CAD and served as normal (control) subjects (Group I), while 14 patients had extensive coronary disease (Group II). All pre-ouabain parameters were within the normal limits in Group I. After ouabain infusion, all indices of LV contractility: dP/dt, VCF, and ejection fraction rose significantly in the normal group, while LV filling pressure and end-diastolic volume remained unchanged. The baseline hemodynamic and volumetric values for Group II patients corresponded closely to their normal (Group I) counterparts, and exhibited similar changes after ouabain administration. Eight patients in Group II also had regional disorders of LV contractility, delineated by 23 abnormal hemiaxes of shortening. After ouabain, 15 out of 23 asynergic segments (65 per cent) improved, seven remained unchanged, and one worsened. It is therefore concluded that rapid digitalization not only enhances LV performance in normal subjects and in patients with CAD, but can also markedly reduce the extent of LV asynergy.

  1. Three-dimensional echocardiography in various types of heart disease: a comparison study of magnetic resonance imaging and 64-slice computed tomography in a real-world population.

    Science.gov (United States)

    Squeri, Angelo; Censi, Stefano; Reverberi, Claudio; Gaibazzi, Nicola; Baldelli, Marco; Binno, Simone Maurizio; Properzi, Enrico; Bosi, Stefano

    2017-03-01

    Accurate quantification of left ventricular (LV) volumes [end-diastolic volume (EDV) and end-systolic volume (ESV)] and ejection fraction (EF) is of critical importance. The development of real-time three-dimensional echocardiography (RT3DE) has shown better correlation than two-dimensional (2D) echocardiography with magnetic resonance imaging (MRI) measurements. The aim of our study was to assess the accuracy of RT3DE and 64-slice computed tomography (CT) in the evaluation of LV volumes and function using MRI as the reference standard in a real-world population with various types of heart disease with different chamber geometry. The study population consisted of 66 patients referred for cardiac MRI for various pathologies. All patients underwent cardiac MRI, and RT3DE and 64 slices CT were then performed on a subsequent day. The study population was then divided into 5 clinical groups depending on the underlying heart disease. RT3DE volumes correlated well with MRI values (R 2 values: 0.90 for EDV and 0.94 for ESV). RT3DE measurements of EF correlated well with MRI values (R 2  = 0.86). RT3DE measurements resulted in slightly underestimated values of both EDV and ESV, as reflected by biases of -9.18 and -4.50 mL, respectively. Comparison of RT3DE and MRI in various types of cardiomyopathies showed no statistical difference between different LV geometrical patterns. These results confirm that RT3DE has good accuracy in everyday clinical practice and can be of clinical utility in all types of cardiomyopathy independently of LV geometric pattern, LV diameter or wall thickness, taking into account a slight underestimation of LV volumes and EF compared to MRI.

  2. The influence of type 2 diabetes and gender on ventricular repolarization dispersion in patients with sub-clinic left ventricular diastolic dysfunction.

    Science.gov (United States)

    Jani, Ylber; Kamberi, Ahmet; Xhunga, Sotir; Pocesta, Bekim; Ferati, Fatmir; Lala, Dali; Zeqiri, Agim; Rexhepi, Atila

    2015-01-01

    To assess the influence of type 2 DM and gender, on the QT dispersion, Tpeak-Tend dispersion of ventricular repolarization, in patients with sub-clinic left ventricular diastolic dysfunction of the heart. QT dispersion, that reflects spatial inhomogeneity in ventricular repolarization, Tpeak-Tend dispersion, this on the other hand reflects transmural inhomogeneity in ventricular repolarization, that is increased in an early stage of cardiomyopathy, and in patients with left ventricular diastolic dysfunction, as well. The left ventricular diastolic dysfunction, a basic characteristic of diabetic heart disease (diabetic cardiomyopathy), that developes earlier than systolic dysfunction, suggests that diastolic markers might be sensitive for early cardiac injury. It is also demonstrated that gender has complex influence on indices of myocardial repolarization abnormalities such as QT interval and QT dispersion. We performed an observational study including 300 diabetic patients with similar epidemiological-demographic characteristics recruited in our institution from May 2009 to July 2014, divided into two groups. Demographic and laboratory echocardiographic data were obtained, twelve lead resting electrocardiography, QT, QTc, Tpeak-Tend-intervals and dispersion, were determined manually, and were compared between various groups. For statistical analysis a t-test, X(2) test, and logistic regression are used according to the type of variables. A p value <0.05 was considered statistically significant for a confidence interval of 95%. QTc max. interval, QTc dispersion and Tpeak-Tend dispersion, were significantly higher in diabetic group with subclinical LV (left ventricular) diastolic dysfunction, than in diabetic group with normal left ventricular diastolic function (445.24±14.7 ms vs. 433.55±14.4 ms, P<0.000; 44.98±18.78 ms vs. 32.05±17.9 ms, P<0.000; 32.60±1.6 ms vs. 17.46±2.0 ms, P<0.02. Prolonged QTc max. interval was found in 33% of patients, indiabetic group

  3. Left Ventricle: Fully Automated Segmentation Based on Spatiotemporal Continuity and Myocardium Information in Cine Cardiac Magnetic Resonance Imaging (LV-FAST

    Directory of Open Access Journals (Sweden)

    Lijia Wang

    2015-01-01

    Full Text Available CMR quantification of LV chamber volumes typically and manually defines the basal-most LV, which adds processing time and user-dependence. This study developed an LV segmentation method that is fully automated based on the spatiotemporal continuity of the LV (LV-FAST. An iteratively decreasing threshold region growing approach was used first from the midventricle to the apex, until the LV area and shape discontinued, and then from midventricle to the base, until less than 50% of the myocardium circumference was observable. Region growth was constrained by LV spatiotemporal continuity to improve robustness of apical and basal segmentations. The LV-FAST method was compared with manual tracing on cardiac cine MRI data of 45 consecutive patients. Of the 45 patients, LV-FAST and manual selection identified the same apical slices at both ED and ES and the same basal slices at both ED and ES in 38, 38, 38, and 41 cases, respectively, and their measurements agreed within -1.6±8.7 mL, -1.4±7.8 mL, and 1.0±5.8% for EDV, ESV, and EF, respectively. LV-FAST allowed LV volume-time course quantitatively measured within 3 seconds on a standard desktop computer, which is fast and accurate for processing the cine volumetric cardiac MRI data, and enables LV filling course quantification over the cardiac cycle.

  4. Effect of fluid loading on left ventricular volume and stroke volume variability in patients with end-stage renal disease: a pilot study

    Science.gov (United States)

    Kanda, Hirotsugu; Hirasaki, Yuji; Iida, Takafumi; Kanao-Kanda, Megumi; Toyama, Yuki; Kunisawa, Takayuki; Iwasaki, Hiroshi

    2015-01-01

    Purpose The aim of this study was to investigate fluid loading-induced changes in left ventricular end-diastolic volume (LVEDV) and stroke volume variability (SVV) in patients with end-stage renal disease (ESRD) using real-time three-dimensional transesophageal echocardiography and the Vigileo-FloTrac system. Patients and methods After obtaining ethics committee approval and informed consent, 28 patients undergoing peripheral vascular procedures were studied. Fourteen patients with ESRD on hemodialysis (HD) were assigned to the HD group and 14 patients without ESRD were assigned to the control group. Institutional standardized general anesthesia was provided in both groups. SVV was measured using the Vigileo-FloTrac system. Simultaneously, a full-volume three-dimensional transesophageal echocardiography dataset was acquired to measure LVEDV, left ventricular end-systolic volume, and left ventricular ejection fraction. Measurements were obtained before and after loading 500 mL hydroxyethyl starch over 30 minutes in both groups. Results In the control group, intravenous colloid infusion was associated with a significant decrease in SVV (13.8%±2.6% to 6.5%±2.6%, P<0.001) and a significant increase in LVEDV (83.6±23.4 mL to 96.1±28.8 mL, P<0.001). While SVV significantly decreased after infusion in the HD group (16.2%±6.0% to 6.2%±2.8%, P<0.001), there was no significant change in LVEDV. Conclusion Our preliminary data suggest that fluid responsiveness can be assessed not by LVEDV but also by SVV due to underlying cardiovascular pathophysiology in patients with ESRD. PMID:26527879

  5. Left ventricular fluid dynamics in heart failure: echocardiographic measurement and utilities of vortex formation time.

    Science.gov (United States)

    Poh, Kian Keong; Lee, Li Ching; Shen, Liang; Chong, Eric; Tan, Yee Leng; Chai, Ping; Yeo, Tiong Cheng; Wood, Malissa J

    2012-05-01

    In clinical heart failure (HF), inefficient propagation of blood through the left ventricle (LV) may result from suboptimal vortex formation (VF) ability of the LV during early diastole. We aim to (i) validate echocardiographic-derived vortex formation time (adapted) (VFTa) in control subjects and (ii) examine its utility in both systolic and diastolic HF. Transthoracic echocardiography was performed in 32 normal subjects and in 130 patients who were hospitalized with HF [91, reduced ejection fraction (rEF) and 39, preserved ejection fraction (pEF)]. In addition to biplane left ventricular ejection fraction (LVEF) and conventional parameters, the Tei index and tissue Doppler (TD) indices were measured. VFTa was obtained using the formula: 4 × (1 - β)/π × α³ × LVEF, where β is the fraction of total transmitral diastolic stroke volume contributed by atrial contraction (assessed by time velocity integral of the mitral E- and A-waves) and α is the biplane end-diastolic volume (EDV)(1/3) divided by mitral annular diameter during early diastole. VFTa was correlated with demographic, cardiac parameters, and a composite clinical endpoint comprising cardiac death and repeat hospitalization for HF. Mean VFTa was 2.67 ± 0.8 in control subjects; reduced in HF, preserved EF HF, 2.21 ± 0.8; HF with reduced EF, 1.25 ± 0.6 (PTD early diastolic myocardial velocities (E', septal, r = 0.46; lateral, r = 0.43), systolic myocardial velocities (S', septal, r = 0.47; lateral, r = 0.41), and inversely with the Tei index (r = -0.41); all Ps < 0.001. Sixty-two HF patients (49%) met the composite endpoint. VFTa of <1.32 was associated with significantly reduced event-free survival (Kaplan Meier log rank = 16.3, P= 0.0001) and predicted the endpoint with a sensitivity and specificity of 65 and 72%, respectively. VFTa, a dimensionless index, incorporating LV geometry, systolic and diastolic parameters, may be useful in the diagnosis and prognosis of HF.

  6. Sixty-four-slice multidetector computed tomography for preoperative evaluation of left ventricular function and mass in patients with mitral regurgitation: comparison with magnetic resonance imaging and echocardiography

    International Nuclear Information System (INIS)

    Guo, Ying-kun; Yang, Zhi-gang; Ning, Gang; Rao, Li; Pen, Ying; Wu, Yang; Dong, Li; Zhang, Tai-ming; Zhang, Xiao-chun; Wang, Qi-ling

    2009-01-01

    Quantitative values of left ventricular (LV) function and muscle mass in patients with mitral regurgitation are independent predictors of cardiac morbidity and mortality. The aim of this study was to prospectively evaluate whether 64-MDCT can assess the LV function in patients with mitral regurgitation with high accuracy when compared with the MRI and echocardiography results. Fifty-one patients with mitral regurgitation underwent retrospectively ECG-gated 64-MDCT, echocardiography, and MRI for assessing the global ventricular function. End-diastolic and end-systolic volume, stroke volume, ejection fraction, and mass were measured on 64-MDCT and echocardiography, and compared with the results measured on MRI which served as the reference standard. Intertechnique agreement was tested by using Pearson's correlation and Bland-Altman analyses. No significant differences were revealed in calculated LV function and mass between the 64-MDCT and MRI (paired t test, p = 0.07-0.53). Pearson's correlation analysis showed the functional parameters and mass correlated closely between the 64-MDCT and MRI (r = 0.89-0.96, p < 0.001). When compared with MRI, echocardiography underestimated the volumetric parameters of LV (paired t test, p = 0.0003-0.004), but significantly overestimated the EF values (p = 0.003), and moderate correlations of functional parameters were obtained (r = 0.78, 0.60, 0.81, and 0.62, respectively). ECG-gated 64-MDCT allows for accurate and reliable assessment of LV function in patients with mitral regurgitation, whereas LV volumes measured by two-dimensional echocardiography were underestimated and the ejection fraction was overestimated when compared with those achieved by using MRI. (orig.)

  7. Time course of infarct healing and left ventricular remodelling in patients with reperfused ST segment elevation myocardial infarction using comprehensive magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ganame, Javier; Messalli, Giancarlo; Dymarkowski, Steven; Abbasi, Kayvan; Bogaert, Jan; Masci, Pier Giorgio; Werf, Frans van de; Janssens, Stefan

    2011-01-01

    To describe the time course of myocardial infarct (MI) healing and left ventricular (LV) remodelling and to assess factors predicting LV remodelling using cardiac MRI. In 58 successfully reperfused MI patients, MRI was performed at baseline, 4 months (4M), and 1 year (1Y) post MI Infarct size decreased between baseline and 4M (p < 0.001), but not at 1Y; i.e. 18 ± 11%, 12 ± 8%, 11 ± 6% of LV mass respectively; this was associated with LV mass reduction. Infarct and adjacent wall thinning was found at 4M, whereas significant remote wall thinning was measured at 1Y. LV end-diastolic and end-systolic volumes significantly increased at 1Y, p < 0.05 at 1Y vs. baseline and vs. 4M; this was associated with increased LV sphericity index. No regional or global LV functional improvement was found at follow-up. Baseline infarct size was the strongest predictor of adverse LV remodelling. Infarct healing, with shrinkage of infarcted myocardium and wall thinning, occurs early post-MI as reflected by loss in LV mass and adjacent myocardial remodelling. Longer follow-up demonstrates ongoing remote myocardial and ventricular remodelling. Infarct size at baseline predicts long-term LV remodelling and represents an important parameter for tailoring future post-MI pharmacological therapies designed to prevent heart failure. (orig.)

  8. Real-time adjustment of ventricular restraint therapy in heart failure.

    Science.gov (United States)

    Ghanta, Ravi K; Lee, Lawrence S; Umakanthan, Ramanan; Laurence, Rita G; Fox, John A; Bolman, Ralph Morton; Cohn, Lawrence H; Chen, Frederick Y

    2008-12-01

    Current ventricular restraint devices do not allow for either the measurement or adjustment of ventricular restraint level. Periodic adjustment of restraint level post-device implantation may improve therapeutic efficacy. We evaluated the feasibility of an adjustable quantitative ventricular restraint (QVR) technique utilizing a fluid-filled polyurethane epicardial balloon to measure and adjust restraint level post-implantation guided by physiologic parameters. QVR balloons were implanted in nine ovine with post-infarction dilated heart failure. Restraint level was defined by the maximum restraint pressure applied by the balloon to the epicardium at end-diastole. An access line connected the balloon lumen to a subcutaneous portacath to allow percutaneous access. Restraint level was adjusted while left ventricular (LV) end-diastolic volume (EDV) and cardiac output was assessed with simultaneous transthoracic echocardiography. All nine ovine successfully underwent QVR balloon implantation. Post-implantation, restraint level could be measured percutaneously in real-time and dynamically adjusted by instillation and withdrawal of fluid from the balloon lumen. Using simultaneous echocardiography, restraint level could be adjusted based on LV EDV and cardiac output. After QVR therapy for 21 days, LV EDV decreased from 133+/-15 ml to 113+/-17 ml (p<0.05). QVR permits real-time measurement and physiologic adjustment of ventricular restraint therapy after device implantation.

  9. Alternative parameters for echocardiographic assessment of fetal diastolic function

    Directory of Open Access Journals (Sweden)

    Zielinsky P.

    2004-01-01

    Full Text Available Alternative methods to assess ventricular diastolic function in the fetus are proposed. Fetal myocardial hypertrophy in maternal diabetes was used as a model of decreased left ventricular compliance (LVC, and fetal respiratory movements as a model of increased LVC. Comparison of three groups of fetuses showed that, in 10 fetuses of diabetic mothers (FDM with septal hypertrophy (SH, the mean excursion index of the septum primum (EISP (ratio between the linear excursion of the flap valve and the left atrial diameter was 0.36 ± 0.09, in 8 FDM without SH it was 0.51 ± 0.09 (P = 0.001, and in the 8 normal control fetuses (NCF it was 0.49 ± 0.12 (P = 0.003. In another study, 28 fetuses in apnea had a mean EISP of 0.39 ± 0.05 which increased to 0.57 ± 0.07 during respiration (P < 0.001. These two studies showed that the mobility of the septum primum was reduced when LVC was decreased and was increased when LVC was enhanced. Mean pulmonary vein pulsatility was higher in 14 FDM (1.83 ± 1.21 than in 26 NCF (1.02 ± 0.31; P = 0.02. In the same fetuses, mean left atrial shortening was decreased (0.40 ± 0.11 in relation to NCF (0.51 ± 0.09; P = 0.011. These results suggest that FDM may have a higher preload than normal controls, probably as a result of increased myocardial mass and LV hypertrophy. Prenatal assessment of LV diastolic function by fetal echocardiography should include analysis of septum primum mobility, pulmonary vein pulsatility, and left atrial shortening.

  10. Age- and gender-specific differences in left and right ventricular cardiac function and mass determined by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sandstede, J.; Lipke, C.; Beer, M.; Hofmann, S.; Pabst, T.; Kenn, W.; Hahn, D.; Neubauer, S.

    2000-01-01

    We examined possible age- and gender-specific differences in the function and mass of left (LV) and right (RV) ventricles in 36 healthy volunteers using cine gradient-recalled echo magnetic resonance imaging. Subjects were divided into four groups (nine men and nine women in each): men aged under 45 years (32 ± 7), women aged under 45 (27 ± 6), men aged over 45 (59 ± 8), and women aged over 45 (57 ± 9). Functional analysis of cardiac volume and mass and of LV wall motion was performed by manual segmentation of the endocardial and epicardial borders of the end-diastolic and end-systolic frame; both absolute and normalized (per square meter body surface area) values were evaluated. With age there was a significant decrease in both absolute and normalized LV and RV chamber volumes (EDV, ESV), while LV and RV masses remained unchanged. Gender-specific differences were found in cardiac mass and volume (for men and women, respectively: LV mass, 155 ± 18 and 110 ± 16 g; LV EDV, 118 ± 27 and 96 ± 21 ml; LV ESV, 40 ± 13 and 29 ± 9 ml; RV mass, 52 ± 10 and 39 ± 5 g; RV EDV, 131 ± 28 and 100 ± 23 ml; RV ESV, 53 ± 17 and 33 ± 15 ml). Normalization to body surface area eliminated differences in LV volumes but not those in LV mass, RV mass, or RV function. Functional parameters such as cardiac output and LV ejection fraction showed nonsignificant or only slight differences and were thus largely independent of age and gender. Intra- and interobserver variability ranged between 1.4 % and 5.9 % for all parameters. Cine magnetic resonance imaging thus shows age- and gender-specific differences in cardiac function, and therefore the evaluation of cardiac function in patients should consider age- and gender-matched normative values. (orig.)

  11. Global and regional left ventricular function: a comparison between gated SPECT, 2D echocardiography and multi-slice computed tomography

    International Nuclear Information System (INIS)

    Henneman, Maureen M.; Bax, Jeroen J.; Holman, Eduard R.; Schuijf, Joanne D.; Jukema, J.W.; Wall, Ernst E. van der; Stokkel, Marcel P.M.; Lamb, Hildo J.; Roos, Albert de

    2006-01-01

    Global and regional left ventricular (LV) function are important indicators of the cardiac status in patients with coronary artery disease (CAD). Therapy and prognosis are to a large extent dependent on LV function. Multi-slice computed tomography (MSCT) has already earned its place as an imaging modality for non-invasive assessment of the coronary arteries, but since retrospective gating to the patient's ECG is performed, information on LV function can be derived. In 49 patients with known or suspected CAD, coronary angiography with MSCT imaging was performed, in addition to gated SPECT and 2D echocardiography. LV end-diastolic and LV end-systolic volumes and LV ejection fraction were analysed with dedicated software (CMR Analytical Software System, Medis, Leiden, The Netherlands for MSCT; gated SPECT by QGS, Cedars-Sinai Medical Center, Los Angeles, CA, USA), and by the biplane Simpson's rule for 2D echocardiography. Regional wall motion was evaluated according to a 17-segment model and a three-point score system. Correlations were fairly good between gated SPECT and MSCT (LVEDV: r=0.65; LVESV: r=0.63; LVEF: r=0.60), and excellent between 2D echocardiography and MSCT (LVEDV: r=0.92; LVESV: r=0.93; LVEF: r=0.80). Agreement for regional wall motion was 95% (κ=0.66) between gated SPECT and MSCT, and 96% (κ=0.73) between 2D echocardiography and MSCT. Global and regional LV function and LV volumes can be adequately assessed with MSCT. Correlations with 2D echocardiography are stronger than with gated SPECT. (orig.)

  12. Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.

    Science.gov (United States)

    Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N

    1993-01-01

    There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Echocardiographic dimensions and function in adults with primary growth hormone resistance (Laron syndrome).

    Science.gov (United States)

    Feinberg, M S; Scheinowitz, M; Laron, Z

    2000-01-15

    Patients with primary growth hormone (GH) resistance-Laron Syndrome (LS)-have no GH signal transmission, and thus, no generation of circulating insulin-like growth factor-I (IGF-I), and should serve as a unique model to explore the controversies concerning the longterm effect of GH/IGF-I deficiency on cardiac dimension and function. We assessed 8 patients with LS (4 men, 4 women) with a mean (+/- SD) age of 38+/-7 years (range 22 to 45), and 8 aged-matched controls (4 men, 4 women) with a mean age of 38+/-9 years (range 18 to 47) by echocardiography at rest, following exercise, and during dobutamine administration. Left ventricular (LV) septum, posterior wall, and end-diastolic diameter were significantly reduced in untreated patients with LS compared with the control group (p<0.05 for all). Systolic Doppler-derived parameters, including LV stroke volume, stroke index, cardiac output, and cardiac index, were significantly lower (p<0.05 for all) than in the control subjects, whereas LV diastolic Doppler parameters, including mitral valve waves E, A, E/A ratio, and E deceleration time, were similar in both groups. LV ejection fraction at rest as well as the stress-induced increment of the LV ejection fraction were similar in both groups. Our results show that untreated patients with long-term IGF-I deficiency have reduced cardiac dimensions and output but normal LV ejection fraction at rest and LV contractile reserve following stress.

  14. Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method

    Energy Technology Data Exchange (ETDEWEB)

    Varga-Szemes, Akos; Schoepf, U.J.; Suranyi, Pal; De Cecco, Carlo N.; Fox, Mary A. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Muscogiuri, Giuseppe [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Medical-Surgical Sciences and Translational Medicine, Rome (Italy); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Cannao, Paola M. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Milan, Scuola di Specializzazione in Radiodiagnostica, Milan (Italy); Renker, Matthias [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Kerckhoff Heart and Thorax Center, Bad Nauheim (Germany); Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Ruzsics, Balazs [Royal Liverpool and Broadgreen University Hospitals, Department of Cardiology, Liverpool (United Kingdom)

    2016-05-15

    To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular (LV) volumes and mass (LVM) using conventional and threshold-based segmentations. Phase-contrast images were used to independently measure stroke volume (SV). LV parameters were evaluated by two independent readers. Evaluation times using the conventional and threshold-based methods were 8.4 ± 1.9 and 4.2 ± 1.3 min, respectively (P < 0.0001). LV parameters measured by the conventional and threshold-based methods, respectively, were end-diastolic volume (EDV) 146 ± 59 and 134 ± 53 ml; end-systolic volume (ESV) 64 ± 47 and 59 ± 46 ml; SV 82 ± 29 and 74 ± 28 ml (flow-based 74 ± 30 ml); ejection fraction (EF) 59 ± 16 and 58 ± 17 %; and LVM 141 ± 55 and 159 ± 58 g. Significant differences between the conventional and threshold-based methods were observed in EDV, ESV, and LVM measurements; SV from threshold-based and flow-based measurements were in agreement (P > 0.05) but were significantly different from conventional analysis (P < 0.05). Excellent inter-observer agreement was observed. Threshold-based LV segmentation provides improved accuracy and faster assessment compared to conventional contour-based methods. (orig.)

  15. Cardiac hemodynamics in PCI : effects of ischemia, reperfusion and mechanical support

    NARCIS (Netherlands)

    Remmelink, M.

    2009-01-01

    The combined pressure-conductance catheter provides the opportunity to continuously assess systolic and diastolic LV function from pressure-volume loops in the catheterization laboratory, enabling accurate assessment of the timing and magnitude of the LV dynamic effects of therapeutic interventions.

  16. Evaluation of left ventricular function using electrocardiographically gated myocardial SPECT with (123)I-labeled fatty acid analog.

    Science.gov (United States)

    Nanasato, M; Ando, A; Isobe, S; Nonokawa, M; Hirayama, H; Tsuboi, N; Ito, T; Hirai, M; Yokota, M; Saito, H

    2001-12-01

    Electrocardiographically (ECG) gated myocardial SPECT with (99m)Tc-tetrofosmin has been used widely to assess left ventricular (LV) function. However, the accuracy of variables using ECG gated myocardial SPECT with beta-methyl-p-(123)I-iodophenylpentadecanoic acid (BMIPP) has not been well defined. Thirty-six patients (29 men, 7 women; mean age, 61.6 +/- 15.6 y) with ischemic heart disease underwent ECG gated myocardial SPECT with (123)I-BMIPP and with (99m)Tc-tetrofosmin and left ventriculography (LVG) within 1 wk. LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), and LV end-systolic volume (LVESV) were determined on gated SPECT using commercially available software for automatic data analysis. These volume-related items on LVG were calculated with an area-length method and were estimated by 2 independent observers to evaluate interobserver validity. The regional wall motion with these methods was assessed visually. LVEF was 41.1% +/- 12.5% on gated SPECT with (123)I-BMIPP, 44.5% +/- 13.1% on gated SPECT with (99m)Tc-tetrofosmin, and 46.0% +/- 12.7% on LVG. Global LV function and regional wall motion between both gated SPECT procedures had excellent correlation (LVEF, r = 0.943; LVEDV, r = 0.934; LVESV, r = 0.952; regional wall motion, kappa = 0.92). However, the correlations of global LV function and regional wall motion between each gated SPECT and LVG were significantly lower. Gated SPECT with (123)I-BMIPP showed the same interobserver validity as gated SPECT with (99m)Tc-tetrofosmin. Gated SPECT with (123)I-BMIPP provides high accuracy with regard to LV function and is sufficiently applicable for use in clinical SPECT. This technique can simultaneously reveal myocardial fatty acid metabolism and LV function, which may be useful to evaluate various cardiac diseases.

  17. Cardiovascular performance with E. coli challenges in a canine model of human sepsis

    International Nuclear Information System (INIS)

    Natanson, C.; Danner, R.L.; Fink, M.P.; MacVittie, T.J.; Walker, R.I.; Conklin, J.J.; Parrillo, J.E.

    1988-01-01

    The authors investigated cardiovascular dysfunction by injecting lethal and nonlethal bacterial challenges into conscious dogs. E coli bacteria of varying numbers were placed in a peritoneal clot. Cardiovascular function was studied with simultaneous radionuclide scans and thermodilution cardiac outputs. In surviving animals, the number of bacteria in the clot increased as the corresponding systolic cardiac function decreased. Cardiac function was measured by left ventricular (LV) ejection fraction (EF) and LV function curves. Furthermore, the diastolic volume-pressure relationship of survivors shifted progressively to the right. This increase in LV size was associated with maintenance of measures of cardiac performance at similar levels. Death occurred only in the group with the highest bacterial dose. Compared with survivors receiving the same number of bacterial, nonsurvivors had a decrease in LV size, a leftward shift in LV diastolic volume-pressure relationship, and a decrease in both LVSWI and SVI. Data from survivors suggest that increasing the number of bacteria produces changes in myocardial compliance and contractility. These changes increase LV size (preload), a major determinant of cardiac performance that possibility enhances survival

  18. Ergotamine-derived dopamine agonists and left ventricular function in Parkinson patients: systolic and diastolic function studied by conventional echocardiography, tissue Doppler imaging, and two-dimensional speckle tracking.

    Science.gov (United States)

    Rasmussen, Vibeke Guldbrand; Poulsen, Steen Hvitfeldt; Dupont, Erik; Ostergaard, Karen; Safikhany, Gholamhossein; Egeblad, Henrik

    2008-11-01

    Ergot-derived dopamine agonists (EDDA) induce fibrotic heart valve disease. We aimed to investigate whether EDDA treatment also affects left ventricular (LV) function. Myocardial function was evaluated in 110 Parkinson patients [mean age (63.4 +/- 9.0 years)] treated for at least 6 months with either EDDA (n = 71) or non-EDDA (n = 39). LV ejection fraction did not differ between EDDA and non-EDDA patients [63 +/- 4% vs. 65 +/- 4% (ns)]. There was no difference in prevalence of diastolic dysfunction between EDDA and non-EDDA patients [7% vs. 8% (ns)]. Finally, averaged LV systolic myocardial strain and longitudinal displacement analysed by means of two-dimensional speckle tracking showed no difference between EDDA and non-EDDA patients [strain: 19 +/- 3% vs. 19 +/- 2% (ns) and longitudinal displacement: 12 +/- 2 mm vs. 12 +/- 2 mm (ns)]. Elevated p-NT-proBNP was found in 38% of EDDA patients and in 59% of non-EDDA patients (ns). In contrast to the well-established association between EDDA treatment and valvular fibrosis, EDDA did not have a detectable adverse impact on myocardial systolic and diastolic function.

  19. Topical minoxidil: cardiac effects in bald man.

    Science.gov (United States)

    Leenen, F H; Smith, D L; Unger, W P

    1988-01-01

    Systemic cardiovascular effects during chronic treatment with topical minoxidil vs placebo were evaluated using a double-blind, randomized design for two parallel groups (n = 20 for minoxidil, n = 15 for placebo). During 6 months of follow-up, blood pressure did not change, whereas minoxidil increased heart rate by 3-5 beats min-1. Compared with placebo, topical minoxidil caused significant increases in LV end-diastolic volume, in cardiac output (by 0.751 min-1) and in LV mass (by 5 g m-2). We conclude that in healthy subjects short-term use of topical minoxidil is likely not to be detrimental. However, safety needs to be established regarding ischaemic symptoms in patients with coronary artery disease as well as for the possible development of LV hypertrophy in healthy subjects during years of therapy. PMID:3191000

  20. Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

    Science.gov (United States)

    Shiota, Takahiro; Jones, Michael; Tsujino, Hiroyuki; Qin, Jian Xin; Zetts, Arthur D.; Greenberg, Neil L.; Cardon, Lisa A.; Panza, Julio A.; Thomas, James D.

    2002-01-01

    BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

  1. Evaluation of single right atrial volume and function with magnetic resonance imaging in children with hypoplastic left heart

    Energy Technology Data Exchange (ETDEWEB)

    Vijarnsorn, Chodchanok [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada); Mahidol University, Siriraj Hospital, Bangkok (Thailand); Myers, Kimberley; Patton, David J. [Alberta Children' s Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Department of Pediatrics, Calgary, AB (Canada); Noga, Michelle; Crawley, Cinzia; Tham, Edythe [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada)

    2016-06-15

    Standardized methods to evaluate atrial properties in single ventricles are lacking. To determine the feasibility of quantifying right atrial volumes and function in hypoplastic left heart using MRI. We studied 15 infants with hypoplastic left heart prior to Glenn surgery (mean age 4.2 months [standard deviation 0.3]) who underwent cardiac MRI with evaluation of atrial volumes and emptying fraction using monoplane two-chamber, monoplane four-chamber, and biplane methods, all of which were compared to the atrial short-axial oblique stack method. We compared atrial end-diastolic volume, end-systolic volume and emptying fraction among these methods. We analyzed reproducibility of the methods using Bland-Altman plots. Both four-chamber and biplane methods showed high correlations for atrial end-diastolic volume (r = 0.7 and r = 0.8, respectively; P < 0.01) and end-systolic volume (r = 0.8 and r = 0.9, respectively; P < 0.01) with small mean differences (-0.2 ± 2.9 standard deviation [SD] ml and -0.8 ± 1.6 ml, respectively, for atrial end-diastolic volume and -0.8 ± 1.5 ml and -0.9 ± 0.9 ml, respectively, for atrial end-systolic volume). The short-axial oblique method was the most reproducible, followed by the four-chamber method. MRI assessment of atrial volume and function is feasible in hypoplastic left heart and might provide further insight into single-ventricle mechanics. (orig.)

  2. HDL mimetic peptide CER-522 treatment regresses left ventricular diastolic dysfunction in cholesterol-fed rabbits.

    Science.gov (United States)

    Merlet, Nolwenn; Busseuil, David; Mihalache-Avram, Teodora; Mecteau, Melanie; Shi, Yanfen; Nachar, Walid; Brand, Genevieve; Brodeur, Mathieu R; Charpentier, Daniel; Rhainds, David; Sy, Gavin; Schwendeman, Anna; Lalwani, Narendra; Dasseux, Jean-Louis; Rhéaume, Eric; Tardif, Jean-Claude

    2016-07-15

    High-density lipoprotein (HDL) infusions induce rapid improvement of experimental atherosclerosis in rabbits but their effect on ventricular function remains unknown. We aimed to evaluate the effects of the HDL mimetic peptide CER-522 on left ventricular diastolic dysfunction (LVDD). Rabbits were fed with a cholesterol- and vitamin D2-enriched diet until mild aortic valve stenosis and hypercholesterolemia-induced LV hypertrophy and LVDD developed. Animals then received saline or 10 or 30mg/kg CER-522 infusions 6 times over 2weeks. We performed serial echocardiograms and LV histology to evaluate the effects of CER-522 therapy on LVDD. LVDD was reduced by CER-522 as shown by multiple parameters including early filling mitral deceleration time, deceleration rate, Em/Am ratio, E/Em ratio, pulmonary venous velocities, and LVDD score. These findings were associated with reduced macrophages (RAM-11 positive cells) in the pericoronary area and LV, and decreased levels of apoptotic cardiomyocytes in CER-522-treated rabbits. CER-522 treatment also resulted in decreased atheromatous plaques and internal elastic lamina area in coronary arteries. CER-522 improves LVDD in rabbits, with reductions of LV macrophage accumulation, cardiomyocyte apoptosis, coronary atherosclerosis and remodelling. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Right ventricular function during one-lung ventilation: effects of pressure-controlled and volume-controlled ventilation.

    Science.gov (United States)

    Al Shehri, Abdullah M; El-Tahan, Mohamed R; Al Metwally, Roshdi; Qutub, Hatem; El Ghoneimy, Yasser F; Regal, Mohamed A; Zien, Haytham

    2014-08-01

    To test the effects of pressure-controlled (PCV) and volume-controlled (VCV) ventilation during one-lung ventilation (OLV) for thoracic surgery on right ventricular (RV) function. A prospective, randomized, double-blind, controlled, crossover study. A single university hospital. Fourteen pairs of consecutive patients scheduled for elective thoracotomy. Patients were assigned randomly to ventilate the dependent lung with PCV or VCV mode, each in a randomized crossover order using tidal volume of 6 mL/kg, I: E ratio 1: 2.5, positive end-expiratory pressure (PEEP) of 5 cm H2O and respiratory rate adjusted to maintain normocapnia. Intraoperative changes in RV function (systolic and early diastolic tricuspid annular velocity (TAV), end-systolic volume (ESV), end-diastolic volume (EDV) and fractional area changes (FAC)), airway pressures, compliance and oxygenation index were recorded. The use of PCV during OLV resulted in faster systolic (10.1±2.39 vs. 5.8±1.67 cm/s, respectively), diastolic TAV (9.2±1.99 vs. 4.6±1.42 cm/s, respectively) (prights reserved.

  4. Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR

    Energy Technology Data Exchange (ETDEWEB)

    Maffei, Erica; Seitun, Sara [Giovanni XXIII Hospital, Cardiovascular Radiology Unit, Monastier di Treviso (Italy); Messalli, Giancarlo; Catalano, Onofrio [SDN Foundation - IRCCS, Naples (Italy); Martini, Chiara; Cademartiri, Filippo [Giovanni XXIII Hospital, Cardiovascular Radiology Unit, Monastier di Treviso (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Nieman, Koen; Rossi, Alexia; Mollet, Nico R. [Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Guaricci, Andrea I. [Azienda Ospedaliero-Universitaria di Foggia, Department of Cardiology, Foggia (Italy); Tedeschi, Carlo [Ospedale San Gennaro, Department of Cardiology, Naples (Italy)

    2012-05-15

    To compare Magnetic Resonance (MR) and Computed Tomography (CT) for the assessment of left (LV) and right (RV) ventricular functional parameters. Seventy nine patients underwent both Cardiac CT and Cardiac MR. Images were acquired using short axis (SAX) reconstructions for CT and 2D cine b-SSFP (balanced-steady state free precession) SAX sequence for MR, and evaluated using dedicated software. CT and MR images showed good agreement: LV EF (Ejection Fraction) (52 {+-} 14% for CT vs. 52 {+-} 14% for MR; r = 0.73; p > 0.05); RV EF (47 {+-} 12% for CT vs. 47 {+-} 12% for MR; r = 0.74; p > 0.05); LV EDV (End Diastolic Volume) (74 {+-} 21 ml/m{sup 2} for CT vs. 76 {+-} 25 ml/m{sup 2} for MR; r = 0.59; p > 0.05); RV EDV (84 {+-} 25 ml/m{sup 2} for CT vs. 80 {+-} 23 ml/m{sup 2} for MR; r = 0.58; p > 0.05); LV ESV (End Systolic Volume)(37 {+-} 19 ml/m{sup 2} for CT vs. 38 {+-} 23 ml/m{sup 2} for MR; r = 0.76; p > 0.05); RV ESV (46 {+-} 21 ml/m{sup 2} for CT vs. 43 {+-} 18 ml/m{sup 2} for MR; r = 0.70; p > 0.05). Intra- and inter-observer variability were good, and the performance of CT was maintained for different EF subgroups. Cardiac CT provides accurate and reproducible LV and RV volume parameters compared with MR, and can be considered as a reliable alternative for patients who are not suitable to undergo MR. circle Cardiac-CT is able to provide Left and Right Ventricular function. circle Cardiac-CT is accurate as MR for LV and RV volume assessment. (orig.)

  5. Effects of timing on intracoronary autologous bone marrow-derived cell transplantation in acute myocardial infarction: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Xu, Jia-Ying; Liu, Dai; Zhong, Yang; Huang, Rong-Chong

    2017-10-16

    Several cell-based therapies for adjunctive treatment of acute myocardial infarction have been investigated in multiple clinical trials, but the timing of transplantation remains controversial. We conducted a meta-analysis of randomized controlled trials to investigate the effects of timing on bone marrow-derived cell (BMC) therapy in acute myocardial infarction (AMI). A systematic literature search of PubMed, MEDLINE, and Cochrane Evidence-Based Medicine databases from January 2000 to June 2017 was performed on randomized controlled trials with at least a 3-month follow-up for patients with AMI undergoing emergency percutaneous coronary intervention (PCI) and receiving intracoronary BMC transfer thereafter. The defined end points were left ventricular (LV) ejection fraction, LV end-diastolic and end-systolic index. The data were analyzed to evaluate the effects of timing on BMC therapy. Thirty-four RCTs comprising a total of 2,307 patients were included; the results show that, compared to the control group, AMI patients who received BMC transplantation showed significantly improved cardiac function. BMC transplantation 3-7 days after PCI (+3.32%; 95% CI, 1.91 to 4.74; P BMC transplantation 3-7 days after PCI reduced LV end-diastolic indexes (-4.48; 95% CI, -7.98 to -0.98; P = 0.01) and LV end-systolic indexes (-6.73; 95% CI, -11.27 to -2.19; P = 0.004). However, in the groups who received BMC transplantation either within 24 hours or later than 7 days there was no significant effect on treatment outcome. In subgroup analysis, the group with LVEF ≤ 50% underwent a significant decrease in LV end-diastolic index after BMC transplantation (WMD = -3.29, 95% CI, -4.49 to -2.09; P BMC transplantation in the group with LVEF ≤ 50% (WMD = -5.25, 95% CI, -9.30 to -1.20; P = 0.01), as well as in patients who received a dose of 10^7-10^8 cells (WMD = -12.99, 95% CI, -19.07 to -6.91; P BMC transfer at 3 to 7 days post-AMI was

  6. Quercetin prevents left ventricular hypertrophy in the Apo E knockout mouse

    Directory of Open Access Journals (Sweden)

    Elena Ulasova

    2013-01-01

    Full Text Available Hypercholesterolemia is a risk factor for the development of hypertrophic cardiomyopathy. Nevertheless, there are few studies aimed at determining the effects of dietary compounds on early or mild cardiac hypertrophy associated with dyslipidemia. Here we describe left ventricular (LV hypertrophy in 12 week-old Apo E−/− hypercholesterolemic mice. The LV end diastolic posterior wall thickness and overall LV mass were significantly increased in Apo E−/− mice compared with wild type (WT controls. Fractional shortening, LV end diastolic diameter, and hemodynamic parameters were unchanged from WT mice. Oral low dose quercetin (QCN; 0.1 µmol QCN/kg body weight for 6 weeks significantly reduced total cholesterol and very low density lipoprotein in the plasma of Apo E−/− mice. QCN treatment also significantly decreased LV posterior wall thickness and LV mass in Apo E−/− mice. Myocardial geometry and function were unaffected in WT mice by QCN treatment. These data suggest that dietary polyphenolic compounds such as QCN may be effective modulators of plasma cholesterol and could prevent maladaptive myocardial remodeling.

  7. The influence of type 2 diabetes and gender on ventricular repolarization dispersion in patients with sub-clinic left ventricular diastolic dysfunction

    Science.gov (United States)

    Jani, Ylber; Kamberi, Ahmet; Xhunga, Sotir; Pocesta, Bekim; Ferati, Fatmir; Lala, Dali; Zeqiri, Agim; Rexhepi, Atila

    2015-01-01

    Objective: To assess the influence of type 2 DM and gender, on the QT dispersion, Tpeak-Tend dispersion of ventricular repolarization, in patients with sub-clinic left ventricular diastolic dysfunction of the heart. Background: QT dispersion, that reflects spatial inhomogeneity in ventricular repolarization, Tpeak-Tend dispersion, this on the other hand reflects transmural inhomogeneity in ventricular repolarization, that is increased in an early stage of cardiomyopathy, and in patients with left ventricular diastolic dysfunction, as well. The left ventricular diastolic dysfunction, a basic characteristic of diabetic heart disease (diabetic cardiomyopathy), that developes earlier than systolic dysfunction, suggests that diastolic markers might be sensitive for early cardiac injury. It is also demonstrated that gender has complex influence on indices of myocardial repolarization abnormalities such as QT interval and QT dispersion. Material and methods: We performed an observational study including 300 diabetic patients with similar epidemiological-demographic characteristics recruited in our institution from May 2009 to July 2014, divided into two groups. Demographic and laboratory echocardiographic data were obtained, twelve lead resting electrocardiography, QT, QTc, Tpeak-Tend-intervals and dispersion, were determined manually, and were compared between various groups. For statistical analysis a t-test, X2 test, and logistic regression are used according to the type of variables. A p value <0.05 was considered statistically significant for a confidence interval of 95%. Results: QTc max. interval, QTc dispersion and Tpeak-Tend dispersion, were significantly higher in diabetic group with subclinical LV (left ventricular) diastolic dysfunction, than in diabetic group with normal left ventricular diastolic function (445.24±14.7 ms vs. 433.55±14.4 ms, P<0.000; 44.98±18.78 ms vs. 32.05±17.9 ms, P<0.000; 32.60±1.6 ms vs. 17.46±2.0 ms, P<0.02. Prolonged QTc max

  8. Increased left ventricular myocardial extracellular volume is associated with longer cardiopulmonary bypass times, biventricular enlargement and reduced exercise tolerance in children after repair of Tetralogy of Fallot.

    Science.gov (United States)

    Riesenkampff, Eugénie; Luining, Wietske; Seed, Mike; Chungsomprasong, Paweena; Manlhiot, Cedric; Elders, Bernadette; McCrindle, Brian W; Yoo, Shi-Joon; Grosse-Wortmann, Lars

    2016-10-26

    Unfavorable left ventricular (LV) remodelling may be associated with adverse outcomes after Tetralogy of Fallot (TOF) repair. We sought to assess T1 cardiovascular magnetic resonance (CMR) markers of diffuse LV myocardial fibrosis in children after TOF repair, and associated factors. In this prospective, cross-sectional study, native (=non-contrast) T1 times and extracellular volume fraction (ECV) were quantified in the LV myocardium using CMR. Results were related to ventricular volumes and function, degree of pulmonary regurgitation, as well as surgical characteristics, and exercise capacity. There was no difference in native T1 times or ECV between 31 TOF patients (age at CMR 13.9 ± 2.4 years, 19 male) and 15 controls (age at CMR 13.4 ± 2.6 years, 7 male). Female TOF patients had higher ECVs than males (25.2 ± 2.9 % versus 22.7 ± 3.3 %, p < 0.05). In the patient group, higher native T1 and ECV correlated with higher Z-Scores of right and left ventricular end-diastolic volumes, but not with reduced left and right ventricular ejection fraction or higher pulmonary regurgitation fraction. Longer cardiopulmonary bypass and aortic cross clamp times at surgery correlated with increased native T1 times and ECVs (r = 0.48, p < 0.05 and r = 0.65, p < 0.01, respectively). Maximum workload (percent of predicted for normal) correlated inversely with ECV (r = -0.62, p < 0.05). Higher native T1 times correlated with worse LV longitudinal (r = 0.50, p < 0.05) and mid short axis circumferential strain (r = 0.38, p < 0.05). As compared to controls, TOF patients did not express higher markers of diffuse fibrosis. Longer cardiopulmonary bypass and aortic cross clamp times at surgery as well as biventricular enlargement and reduced exercise tolerance are associated with markers of diffuse myocardial fibrosis after TOF repair. Female patients have higher markers of diffuse myocardial fibrosis than males.

  9. Dual-source computed tomography. Effect on regional and global left ventricular function assessment compared to magnetic resonance imaging; Untersuchung der regionalen und globalen linksventrikulaeren Funktion mit der Dual-Source-Computertomografie im Vergleich zur Magnetresonanztomografie

    Energy Technology Data Exchange (ETDEWEB)

    Lueders, F.; Seifarth, H.; Wessling, J.; Heindel, W.; Juergens, Kai Uwe [Inst. fuer Klinische Radiologie, Universitaetsklinikum Muenster (Germany); Fischbach, R. [Klinik fuer Radiologie, Nuklearmedizin und Neuroradiologie, Asklepios Klinik Altona (Germany)

    2009-10-15

    Purpose: to determine regional and global left ventricular (LV) functional parameters and to perform segmental wall thickness (SWT) and motion (WM) analysis of dual source CT (DSCT) with optimized temporal resolution versus MRI. Materials and Methods: 30 patients with known or suspected CAD, non-obstructive HCM, DCM, ARVCM, Fallot Tetralogy, cardiac sarcoidosis and cardiac metastasis underwent DSCT and MRI. The DSCT and MR images were evaluated: end-systolic (ESV), end-diastolic LV (EDV) volumes, stroke volume (SV), ejection fraction (EF), and myocardial mass (MM) as well as LV wall thickening and segmental WM applying the AHA model were obtained and statistically analyzed. Results: The mean LV-EDV (r = 0.96) and ESV (r = 0.98) as well as LV-EF (r = 0.97), SV (r = 0.83), and MM (r = 0.95) correlated well. Bland Altman analysis revealed little systematic underestimation of LV-EF (-1.1 {+-} 7.8%), EDV (-0.3 {+-} 18.2 ml), SV (-1.3 {+-} 16.7 ml) and little overestimation of ESV (1.1 {+-} 7.8 ml) and MM (12.8 {+-} 14.4 g) determined by DSCT. Systolic reconstruction time points correlated well (DSCT 32.2 {+-} 6.7 vs. MRI 35.6 {+-} 4.4% RR-interval). The LV wall thickness obtained by DSCT and MRI showed close correlation in all segments (diameter diff 0.42 {+-} 1 mm). In 413 segments (89%) WM abnormalities were equally rated, whereas DSCT tended to underestimate the degree of wall motion impairment. Conclusion: DSCT with optimized temporal resolution enables regional and global LV function analysis as well as segmental WM analysis in good correlation with MRI. However, the degree of WM impairment is slightly underestimated by DSCT. (orig.)

  10. Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoracic 3-dimensional echocardiography

    International Nuclear Information System (INIS)

    Gutberlet, M.; Grothoff, M.; Roettgen, R.; Lange, P.; Felix, R.; Abdul-Khaliq, H.; Schroeter, J.; Schmitt, B.; Vogel, M.

    2003-01-01

    Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8±9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec trademark (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and 3D-echocardiography, the correlation was r=0.97 for the end-systolic volumes, r=0.98 for the end-diastolic volumes, r=0.79 for the end-systolic muscle mass and r=0.77 for the end-diastolic muscle mass. The agreement between both methods was considered good for the calculated end-diastolic volumes and sufficient for the calculated end-systolic volumes. The muscle mass calculations showed larger differences especially for the end-systolic mass. Mean intraobserver variability was 18.6% for end-systolic and 8.3% for end-diastolic volumes. Conclusion: In patients with an abnormal left ventricular configuration due to congenital heart disease, the new method of 3D-echocardiography is sufficient for volume calculations in preselected patients. The high intraobserver variability is still a limitation of transthoracic 3D-echocardiography in comparison to MRI. (orig.) [de

  11. MANAGING HIGH-END, HIGH-VOLUME INNOVATIVE PRODUCTS

    Directory of Open Access Journals (Sweden)

    Gembong Baskoro

    2008-01-01

    Full Text Available This paper discuses the concept of managing high-end, high-volume innovative products. High-end, high-volume consumer products are products that have considerable influence to the way of life. Characteristic of High-end, high-volume consumer products are (1 short cycle time, (2 quick obsolete time, and (3 rapid price erosion. Beside the disadvantages that they are high risk for manufacturers, if manufacturers are able to understand precisely the consumer needs then they have the potential benefit or success to be the market leader. High innovation implies to high utilization of the user, therefore these products can influence indirectly to the way of people life. The objective of managing them is to achieve sustainability of the products development and innovation. This paper observes the behavior of these products in companies operated in high-end, high-volume consumer product.

  12. The Doppler echocardiographic myocardial performance index predicts left-ventricular dilation and cardiac death after myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To investigate the value of the Doppler-derived myocardial performance index to predict early left-ventricular (LV) dilation and cardiac death after a first acute myocardial infarction (AMI), Doppler echocardiography was performed within 24 h of hospital admission, on day 5, 1 and 3 months after...... AMI in 125 consecutive patients. The index measured on day 1 correlated well with the change in end-diastolic volume index observed from day 1 to 3 months following AMI (r = 0.66, p 0.0001). One-year survival in patients with Doppler index index > or = 0......, we conclude that the Doppler echocardiographic myocardial performance index is a predictor of LV dilation and cardiac death after a first AMI....

  13. Differential effects comparing exercise and pharmacologic stress on left ventricular function using gated Tc-99m sestamibi SPECT

    International Nuclear Information System (INIS)

    Ohtaki, Yuka; Chikamori, Taishiro; Igarashi, Yuko; Hida, Satoshi; Tanaka, Hirokazu; Hatano, Tsuguhisa; Usui, Yasuhiro; Miyagi, Manabu; Yamashina, Akira

    2008-01-01

    Although post-ischemic stunning has emerged as an important marker for severe coronary artery disease (CAD), differences in stress methods may have different effects on left ventricular (LV) volumes and function. To assess differential effects comparing exercise and pharmacologic stress on the LV measurements, 99m Tc-sestamibi gated single-photon emission computed tomography (SPECT) acquired more than 30 min after stress and at rest was evaluated in 38 patients undergoing adenosine triphosphate (ATP) stress (ATP group) and 38 age- and sex-matched patients subjected to exercise stress (Ex group) among 268 patients with normal SPECT findings. Coronary risk factors and LV volumetric measurements at baseline were similar in the two groups. Compared with volumetric measurements at rest, end-diastolic volume (EDV) increased (72±21 ml to 74±21 ml; P=0.01), end-systolic volume increased (25±12 ml to 28±13 ml; P=0.001), and ejection fraction (EF) decreased after stress (66%±8% to 63%±9%; P<0.002) in the ATP group. In the Ex group, by contrast, no such change was observed. In addition, changes in EDV (3±6 vs. -1±5 ml; P=0.01) and the stress-to-rest ratio of EDV (1.04±0.09 vs. 0.99±0.08; P<0.02) after stress were greater in the ATP than in the Ex group. Differential effects of stress methods on LV volumes persist more than 30 min after the stress. These findings should be kept in mind when interpreting post-ischemic stunning. (author)

  14. Real-time 3D echo in patient selection for cardiac resynchronization therapy.

    Science.gov (United States)

    Kapetanakis, Stamatis; Bhan, Amit; Murgatroyd, Francis; Kearney, Mark T; Gall, Nicholas; Zhang, Qing; Yu, Cheuk-Man; Monaghan, Mark J

    2011-01-01

    this study investigated the use of 3-dimensional (3D) echo in quantifying left ventricular mechanical dyssynchrony (LVMD), its interhospital agreement, and potential impact on patient selection. assessment of LVMD has been proposed as an improvement on conventional criteria in selecting patients for cardiac resynchronization therapy (CRT). Three-dimensional echo offers a reproducible assessment of left ventricular (LV) structure, function, and LVMD and may be useful in selecting patients for this intervention. we studied 187 patients at 2 institutions. Three-dimensional data from baseline and longest follow-up were quantified for volume, left ventricular ejection fraction (LVEF), and systolic dyssynchrony index (SDI). New York Heart Association (NYHA) functional class was assessed independently. Several outcomes from CRT were considered: 1) reduction in NYHA functional class; 2) 20% relative increase in LVEF; and 3) 15% reduction in LV end-systolic volume. Sixty-two cases were shared between institutions to analyze interhospital agreement. there was excellent interhospital agreement for 3D-derived LV end-diastolic and end- systolic volumes, EF, and SDI (variability: 2.9%, 1%, 7.1%, and 7.6%, respectively). Reduction in NYHA functional class was found in 78.9% of patients. Relative improvement in LVEF of 20% was found in 68% of patients, but significant reduction in LV end-systolic volume was found in only 41.5%. The QRS duration was not predictive of any of the measures of outcome (area under the curve [AUC]: 0.52, 0.58, and 0.57 for NYHA functional class, LVEF, and LV end-systolic volume), whereas SDI was highly predictive of improvement in these parameters (AUC: 0.79, 0.86, and 0.66, respectively). For patients not fulfilling traditional selection criteria (atrial fibrillation, QRS duration <120 ms, or undergoing device upgrade), SDI had similar predictive value. A cutoff of 10.4% for SDI was found to have the highest accuracy for predicting improvement following

  15. Correlation of radiological assessment of congestive heart failure with left ventricular end-diastolic pressure

    International Nuclear Information System (INIS)

    Herman, P.G.; Kahn, A.; Kallman, C.E.; Rojas, K.A.; Bodenheimer, M.M.

    1988-01-01

    Left ventricular end-diastolic pressure (LVEDP) has been considered a reliable indicator of left ventricular function. The purpose of this study was to correlate the radiologic assessment of congestive heart failure with LVEDP. The population of the study consisted of 85 consecutive cases in four ranges of LVEDP ( 24). The PA chest radiographs obtained 1 day prior to cardiac catherization were assessed for radiological evidence of congestive heart failure and were graded from normal to abnormal (0-3). The results will be summarized in the authors' presentation. The discordance of radiological assessment of congestive heart failure in patients with elevated LVEDP will be discussed in light of recent advances in pathophysiologic understanding of left ventricular function and the impact of new classes of drugs in the management of these patients

  16. Cardiac pathologies in female carriers of Duchenne muscular dystrophy assessed by cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Schelhorn, Juliane; Schemuth, Haemi; Nensa, Felix; Nassenstein, Kai; Forsting, Michael; Schlosser, Thomas; Schoenecker, Anne; Neudorf, Ulrich; Schara, Ulrike

    2015-01-01

    Duchenne muscular dystrophy (DMD) is the most common and severe dystrophinopathy. DMD carriers rarely present with clinical symptoms, but may suffer from cardiac involvement. Because echocardiographic findings are inconsistent and cardiac magnetic resonance imaging (CMRI) data are limited, this study sought to investigate asymptomatic carriers for cardiac abnormalities using CMRI. Fifteen genetically confirmed DMD carriers (age, 32.3 ± 10.2 years) were prospectively examined on a 1.5T MR system. Cine, T2, and late-gadolinium-enhanced (LGE) images were acquired, and were evaluated in consensus by two experienced readers. Left ventricular (LV) parameters were analysed semiautomatically, normalized to BSA. Normalized LV end-diastolic volume was increased in 7 % (73.7 ± 16.8 ml/m 2 ; range, 48-116 ml/m 2 ) and normalized LV end-systolic volume in 20 % (31.5 ± 13.3 ml/m 2 ; range, 15-74 ml/m 2 ). EF was reduced in 33 % (58.4 ± 7.6 %; range, 37-69 %) and normalized LV myocardial mass in 80 % (40.5 ± 6.8 g/m 2 ; range, 31-55 g/m 2 ). In 80 %, regional myocardial thinning was detected in more than one segment. In 13 % and 40 %, apical-lateral accentuation of LV non-compaction was present. LGE was found in 60 % (midmyocardial inferolateral accentuation). Given the high frequency of cardiac pathologies detected by CMRI, regular cardiac risk assessment is advisable for DMD carriers. Besides clinical examination, CMRI is an excellent tool for this purpose. (orig.)

  17. Pulmonary capillary recruitment in response to hypoxia in healthy humans: a possible role for hypoxic pulmonary venoconstriction?

    DEFF Research Database (Denmark)

    Taylor, Bryan J; Kjaergaard, Jesper; Snyder, Eric M

    2011-01-01

    We examined mechanisms by which hypoxia may elicit pulmonary capillary recruitment in humans. On separate occasions, twenty-five healthy adults underwent exposure to intravenous saline infusion (30 ml/kg ∼ 15 min) or 17-h normobaric hypoxia ( [FIO2 = 12.5%). Cardiac output (Q) and pulmonary...... capillary blood volume (Vc) were measured before and after saline infusion and hypoxic-exposure by a rebreathing method. Pulmonary artery systolic pressure (sPpa) and left ventricular (LV) diastolic function were assessed before and after hypoxic-exposure via echocardiography. Saline infusion increased Q......Ppa and LV diastolic function. In conclusion, hypoxia-induced pulmonary capillary recruitment in humans is only partly accounted for by changes in Q, sPpa and LV diastolic function. We speculate that hypoxic pulmonary venoconstriction may play a role in such recruitment....

  18. Left ventricular functional parameters and geometric patterns in Korean adults on coronary CT angiography with a 320-detector-row CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam; Cho, Won Jin; Kim, Young Dae [College of Medicine, Dong-A University, Busan (Korea, Republic of); Shin, Kyung Min; Lim, Jae Kwang; Lee, Jong Min [Dept. of Radiology, Kyungpook National University, Daegu (Korea, Republic of)

    2017-08-01

    To assess the normal reference values of left ventricle (LV) functional parameters in Korean adults on coronary CT angiography (CCTA) with a 320-detector-row CT scanner, and to analyze sex-related differences and correlations with various clinical characteristics. This study retrospectively enrolled 172 subjects (107 men and 65 women; age, 58 ± 10.9 years; body surface area [BSA], 1.75 ± 0.2 m{sup 2}) who underwent CCTA without any prior history of cardiac disease. The following parameters were measured by post-processing the CT data: LV volume, LV functional parameters (ejection fraction, stroke volume, cardiac output, etc.), LV myocardial mass, LV inner diameter, and LV myocardial thickness (including septal wall thickness [SWT], posterior wall thickness [PWT], and relative wall thickness [RWT = 2 × PWT / LV inner diameter]). All of the functional or volumetric parameters were normalized using the BSA. The general characteristics and co-morbidities for the enrolled subjects were recorded, and the correlations between these factors and the LV parameters were then evaluated. The LV myocardial thickness (SWT, 1.08 ± 0.18 cm vs. 0.90 ± 0.17 cm, p < 0.001; PWT, 0.91 ± 0.15 cm vs. 0.78 ± 0.10 cm, p < 0.001; RWT, 0.38 ± 0.08 cm vs. 0.33 ± 0.05 cm, p < 0.001), LV volume (LV end-diastolic volume, 112.9 ± 26.1 mL vs. 98.2 ± 21.0 mL, p < 0.001; LV end-systolic volume, 41.7 ± 14.7 mL vs. 33.7 ± 12.2 mL, p = 0.001) and mass (145.0 ± 29.1 g vs. 107.9 ± 20.0 g, p < 0.001) were significantly greater in men than in women. However, these differences were not significant after normalization using BSA, except for the LV mass (LV mass index, 79.6 ± 14.0 g/m{sup 2} vs. 66.2 ± 11.0 g/m{sup 2},p < 0.001). The cardiac output and ejection fraction were not significantly different between the men and women (cardiac output, 4.3 ± 1.0 L/min vs. 4.2 ± 0.9 L/min, p = 0.452; ejection fraction, 63.4 ± 7.7% vs. 66.4 ± 7.6%, p = 0.079). Most of the LV parameters were

  19. Clinical and ultrasound results after aortic valve replacement: intermediate-term follow-up with the St. Jude Medical prosthesis.

    Science.gov (United States)

    Montalescot, G; Thomas, D; Drobinski, G; Evans, J I; Vicaut, E; Chatellier, G; Whyte, R I; Busquet, P; Bejean-Lebuisson, A; Grosgogeat, Y

    1989-07-01

    Mortality, morbidity, quality of life, and left ventricular (LV) function were evaluated in 49 patients after aortic valve replacement with the St. Jude prosthesis. Total follow-up was 2577 patient-months; survivors were followed-up for 4 to 7 years by clinical examination and echocardiography. The actuarial survival rate at 6 years was 79.6%, and there were no valve-related deaths. The linearized rates for thromboembolism and hemorrhage were 0.93% and 3.26% per patient-year, respectively. In 34% of the survivors the quality of life was poor. In the first three postoperative months, patients with aortic stenosis (n = 12) had a significant decrease in the muscle cross-sectional area (p less than 0.01) and patients with aortic regurgitation (n = 11) had decreases in both LV end-diastolic diameter (p less than 0.05) and cross-sectional area (p less than 0.001). All of these results were maintained at 5 years without modification of LV systolic function. Despite the good overall results, six patients deteriorated and had major LV dilatation. Multivariate logistic regression analysis identified two independent preoperative variables associated with a poor outcome defined as death of LV dysfunction (p less than 0.05): age and end-diastolic diameter. Thus meticulous follow-up showed a high incidence of hemorrhage and a poor quality of life in many of the survivors. It was concluded that in high-risk patients (age and end-diastolic diameter) surgery should probably be considered earlier.

  20. First third filling parameters of left ventricle assessed from gated equilibrium studies in patients with various heart diseases

    Energy Technology Data Exchange (ETDEWEB)

    Adatepe, M.H.; Nichols, K.; Powell, O.M.; Isaacs, G.H.

    1984-01-01

    The authors determined the first third filling fraction (1/3 FF), the maximum filling rate (1/3 FR) and the mean filling rate (1/3 MFR) for the first third diastolic filling period of the left ventricle in patients with coronary artery disease (CAD), valvular heart disease (VHD), pericardial effusion (PE), cardiomyopathies (CM), chronic obstructive lung disease (COPD) and in 5 normals-all from resting gated equilibrium studies. Parameters are calculated from the third order Fourier fit to the LV volume curve and its derivative. 1/3 FF% = 1/3 diastolic count - end systolic count / 1/3 diastolic count x 100. Patients with CAD are divided into two groups: Group I with normal ejection fraction (EF) and wall motion (WM); Group II with abnormal EF and WM. Results are shown in the table. Abnormal filling parameters are found not only in CAD but in VHD, PE and CM. The authors conclude that the first third LV filling parameters are sensitive but non-specific indicators of filling abnormalities caused by diverse etiologic factors. Abnormal first third filling parameters may occur in the presence of a normal resting EF and WM in CAD.

  1. Evaluation of P-Wave Dispersion, Diastolic Function, and Atrial Electromechanical Conduction in Pediatric Patients with Subclinical Hypothyroidism.

    Science.gov (United States)

    Irdem, Ahmet; Aydın Sahin, Derya; Kervancioglu, Mehmet; Baspinar, Osman; Sucu, Murat; Keskin, Mehmet; Kilinc, Metin

    2016-09-01

    This study aimed to evaluate ventricular diastolic dysfunction, inter- and intraatrial conduction delay, and P-wave dispersion in pediatric patients with subclinical hypothyroidism. The study comprised a total of 30 pediatric patients with subclinical hypothyroidism (SH) (mean age 7.8 ± 3.2 years) and 30 healthy children (mean age 8.4 ± 3.6 years) as the control group. A SH diagnosis was made in the event of increased serum thyroid-stimulating hormone (TSH) and decreased serum free triiodothyronine (T3 ) and free thyroxine (T4 ) concentrations. Conventional Doppler imaging (TDI) showed low mitral early diastolic E-wave velocity and E/A ratio (P wave velocity (P = 0.001) in hypothyroidism patients. Moreover, patients with hypothyroidism had significantly lower left ventricular (LV) septal Em velocity and Em /Am ratios compared with the control group (P wave dispersion was significantly different in the pediatric patients with hypothyroidism (P wave dispersion, and ventricle diastolic dysfunction in pediatric patients with hypothyroidism. © 2016, Wiley Periodicals, Inc.

  2. Serial assessment of left ventricular function in various patient groups with Tl-201 gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wei Lingge; Kadoya, Masumi; Momose, Mitsuhiro; Kurozumi, Masahiro; Matsushita, Tsuyoshi; Yamada, Akira

    2007-01-01

    The present study was performed to assess stress-related left ventricular (LV) function variations in various patient groups and to determine if they were affected by sex or the type of stress experienced. We used thallium (Tl)-201 gated myocardial perfusion single-photon emission computed tomography (SPECT) for the analysis. A total of 270 patients were examined by electrocardiography-gated myocardial perfusion SPECT imaging to assess LV function. After injection of Tl-201 at a dose of 111 MBq at peak stress, SPECT scans were acquired at 10 min (after stress) and 3 h (rest) after injection on a three-headed camera. In the normal perfusion group, the mean LV ejection fraction (LVEF) was significantly higher, and both the end-diastolic volume index (EDVI) and end-systolic volume index (ESVI) were significantly lower in women than in men (P<0.05). Poststress stunning occurred in 29 of 98 patients (30.0%) in the ischemia group and in 42 of 90 patients (46.7%) in the fixed group. There was a significant difference in poststress stunning between bicycle ergometer stress and dipyridamole stress (P<0.05). In patients with normal perfusion, LVEF, EDVI, and ESVI determined by gated Tl-201 SPECT should be corrected for sex. In addition, the influence of the type of stress should be considered when assessing stress-related LV function variations. (author)

  3. Clinical characteristics of the respiratory and cardiovascular systems in patients with combination of chronic obstructive pulmonary disease and heart failure

    Directory of Open Access Journals (Sweden)

    I. I. Vyshnyvetskyy

    2017-06-01

    deterioration of the heart geometry (increasing of myocardial mass index, indexes of LV end-systolic and end-diastolic volumes, increased frequency of all variants of LV pathological remodeling detection, RV wall thickness, the ratio of RV/LV diastolic function impairment (increased frequency of all types diastolic dysfunction detection; development of pulmonary hypertension (increasing of the maximum flow velocity, pressure gradient, and the systolic pressure in the pulmonary artery, the frequency of detection of the absence of a-wave. Conclusions. The presence of heart failure in patients with COPD worsens important clinical, laboratory and instrumental parameters of the cardiovascular and respiratory systems.

  4. Absent end diastolic flow of umbilical artery Doppler: pregnancy outcome in 62 cases.

    Science.gov (United States)

    Poulain, P; Palaric, J C; Milon, J; Betremieux, P; Proudhon, J F; Signorelli, D; Grall, J Y; Giraud, J R

    1994-02-01

    We retrospectively studied the outcome of pregnancy in 62 cases of absent end diastolic flow (AEDF) of umbilical artery Doppler flow velocity waveform. The history of pregnancies revealed that nearly all were of high risk. Many cases presented cerebral (65%) or uterine (55.5%) Doppler flow abnormalities, or both (38%). We noted 10 fetal deaths and decided 7 pregnancy terminations. Malformation and chromosomal defect rate was 16%. We noted 44 (71%) live-births, a very high rate of cesarean section (86%), prematurity (75%), small for gestational age (39%). Forty-five percent of the neonates had a 1-min Apgar score under 7, which dropped to 27% at 5 min. Neonate mortality rate was 6.9% and the total mortality rate was 34% (21/62). Morbidity was significant (7 cases with severe morbidity, 2 cases with chromosomal abnormality of poor prognosis). We compared different sub-groups with a view to looking for some prenatal factors which predict poor neonatal outcome in case of AEDF.

  5. Predictors of Renal Denervation Efficacy in the Treatment of Resistant Hypertension.

    Science.gov (United States)

    Ripp, Tatiana M; Mordovin, Victor F; Pekarskiy, Stanislav E; Ryabova, Tamara R; Zlobina, Marina V; Baev, Andrei E; Anfinogenova, Yana; Popov, Sergey V

    2015-12-01

    The aims of the study were to evaluate the effects of renal sympathetic denervation (RSD) on the heart and to identify the predictors of RSD efficacy in patients with resistant arterial hypertension. The study comprised 60 RSD patients (54.6 ± 9.5 years) who received full-dose antihypertensive therapy (4.1 drugs) including diuretics. Initially, 58.6% of patients had abnormal left ventricular (LV) diastolic function. All patients received echocardiography before and 24 weeks after RSD. Renal sympathetic denervation was achieved through the endovascular radiofrequency ablation (RFA) of the renal arteries. Drug therapy continued for the entire period of observation. After RSD, all patients were retrospectively assigned to two groups: group 1 comprised patients (n = 22; 36.7%) in whom the myocardial mass (MM) of the left ventricle decreased by more than 10 g after RSD; group 2 comprised patients (n = 38; 63.3%) in whom LV MM increased or decreased by less than 10 g. Anthropometry, arterial blood pressure, heart rate, therapy, and LV end-diastolic dimensions (EDD) were comparable in these groups. After RSD, the values of office blood pressure significantly decreased and MM regressed by more than 10 g in 36.7% of patients; LV diastolic function normalized in 31% of patients, and diastolic dysfunction improved in 14% of patients. The study found the associations between the initial LV wall dimensions and LV MM changes. Unlike LV EDD, arterial blood pressure, or heart rate, the initial values of LV wall thickness predicted LV MM regress. #NCT01499810 https://clinicaltrials.gov/ct2/show/NCT01499810.

  6. Fully automated segmentation of left ventricle using dual dynamic programming in cardiac cine MR images

    Science.gov (United States)

    Jiang, Luan; Ling, Shan; Li, Qiang

    2016-03-01

    Cardiovascular diseases are becoming a leading cause of death all over the world. The cardiac function could be evaluated by global and regional parameters of left ventricle (LV) of the heart. The purpose of this study is to develop and evaluate a fully automated scheme for segmentation of LV in short axis cardiac cine MR images. Our fully automated method consists of three major steps, i.e., LV localization, LV segmentation at end-diastolic phase, and LV segmentation propagation to the other phases. First, the maximum intensity projection image along the time phases of the midventricular slice, located at the center of the image, was calculated to locate the region of interest of LV. Based on the mean intensity of the roughly segmented blood pool in the midventricular slice at each phase, end-diastolic (ED) and end-systolic (ES) phases were determined. Second, the endocardial and epicardial boundaries of LV of each slice at ED phase were synchronously delineated by use of a dual dynamic programming technique. The external costs of the endocardial and epicardial boundaries were defined with the gradient values obtained from the original and enhanced images, respectively. Finally, with the advantages of the continuity of the boundaries of LV across adjacent phases, we propagated the LV segmentation from the ED phase to the other phases by use of dual dynamic programming technique. The preliminary results on 9 clinical cardiac cine MR cases show that the proposed method can obtain accurate segmentation of LV based on subjective evaluation.

  7. Evaluation of left ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Thomsen, C; Mehlsen, J

    1986-01-01

    Left ventricular end-diastolic and end-systolic volumes were determined in 17 patients with different levels of left ventricular function by magnetic resonance imaging (MRI). A 1.5 Tesla Magnet was used obtaining ECG triggered single and multiple slices. Calculated cardiac outputs were compared...

  8. Athlete's Heart: Is the Morganroth Hypothesis Obsolete?

    Science.gov (United States)

    Haykowsky, Mark J; Samuel, T Jake; Nelson, Michael D; La Gerche, Andre

    2018-05-01

    In 1975, Morganroth and colleagues reported that the increased left ventricular (LV) mass in highly trained endurance athletes versus nonathletes was primarily due to increased end-diastolic volume while the increased LV mass in resistance trained athletes was solely due to an increased LV wall thickness. Based on the divergent remodelling patterns observed, Morganroth and colleagues hypothesised that the increased "volume" load during endurance exercise may be similar to that which occurs in patients with mitral or aortic regurgitation while the "pressure" load associated with performing a Valsalva manoeuvre (VM) during resistance exercise may mimic the stress imposed on the heart by systemic hypertension or aortic stenosis. Despite widespread acceptance of the four-decade old Morganroth hypothesis in sports cardiology, some investigators have questioned whether such a divergent "athlete's heart" phenotype exists. Given this uncertainty, the purpose of this brief review is to re-evaluate the Morganroth hypothesis regarding: i) the acute effects of resistance exercise performed with a brief VM on LV wall stress, and the patterns of LV remodelling in resistance-trained athletes; ii) the acute effects of endurance exercise on biventricular wall stress, and the time course and pattern of LV and right ventricular (RV) remodelling with endurance training; and iii) the value of comparing "loading" conditions between athletes and patients with cardiac pathology. Copyright © 2018. Published by Elsevier B.V.

  9. Relation of Left Atrial Size, Cardiac Morphology, and Clinical Outcome in Asymptomatic Aortic Stenosis

    DEFF Research Database (Denmark)

    Christensen, Nicolaj Lyhne; Dahl, Jordi; Carter-Storch, Rasmus

    2017-01-01

    characterized by higher LV mass index (73 ± 17 g/m² vs. 66 ± 16 g/m² , p=0.03), increased right ventricle (70 ± 14 ml/m² vs. 63 ± 12 ml/m², p=0.01) and LV end-diastolic volume index (84 ± 18 ml/m² vs. 77 ± 16 ml/m², p=0.05), and higher brain natriuretic peptide (BNP). No difference in late enhancement was seen......Left atrial (LA) dilatation in asymptomatic severe aortic stenosis (AS) may be an indicator of advanced disease. The aim was to investigate the association between LA volume index (LAVi) and left ventricular (LV) morphology assessed with cardiac magnetic resonance imaging (cMRI), and to assess...... underwent echocardiography, cMRI, exercise test, and patients were followed for the composite endpoint of death, readmission or aortic valve replacement. AVA index was similar (0.45 ± 0.08 cm² /m² vs. 0.45 ± 0.09 cm², p=0.85) in patients with a dilated and normal LA. On cMRI patients with dilated LA were...

  10. Tilapia lake virus (TiLV): Literature review

    OpenAIRE

    Jansen, Mona Dverdal; Mohan, Chadag Vishnumurthy

    2017-01-01

    Tilapia lake virus (TiLV) is an emerging infectious agent that has recently been identified in diseased tilapia on three continents. At the time of writing, scientific publications have reported TiLV in samples collected from Colombia, Ecuador, Egypt, Israel and Thailand. While the link between TiLV and disease outbreaks in Israel and Thailand are well documented, further investigations are being undertaken to determine the significance of TiLV in the other countries. Israel and Taiwan Provin...

  11. Physiological Interaction of Heart and Lung in Thoracic Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ghobadi, Ghazaleh; Veen, Sonja van der [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Bartelds, Beatrijs [Center for Congenital Heart Disease, Beatrix Children Hospital, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Boer, Rudolf A. de [Department of Cardiology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Dickinson, Michael G. [Center for Congenital Heart Disease, Beatrix Children Hospital, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Jong, Johan R. de [Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Faber, Hette; Niemantsverdriet, Maarten [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Brandenburg, Sytze [Kernfysisch Versneller Instituut, University of Groningen, Groningen (Netherlands); Berger, Rolf M.F. [Center for Congenital Heart Disease, Beatrix Children Hospital, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Langendijk, Johannes A. [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Coppes, Robert P. [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Luijk, Peter van, E-mail: p.van.luijk@umcg.nl [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands)

    2012-12-01

    Introduction: The risk of early radiation-induced lung toxicity (RILT) limits the dose and efficacy of radiation therapy of thoracic tumors. In addition to lung dose, coirradiation of the heart is a known risk factor in the development RILT. The aim of this study was to identify the underlying physiology of the interaction between lung and heart in thoracic irradiation. Methods and Materials: Rat hearts, lungs, or both were irradiated to 20 Gy using high-precision proton beams. Cardiopulmonary performance was assessed using breathing rate measurements and F{sup 18}-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG-PET) scans biweekly and left- and right-sided cardiac hemodynamic measurements and histopathology analysis at 8 weeks postirradiation. Results: Two to 12 weeks after heart irradiation, a pronounced defect in the uptake of {sup 18}F-FDG in the left ventricle (LV) was observed. At 8 weeks postirradiation, this coincided with LV perivascular fibrosis, an increase in LV end-diastolic pressure, and pulmonary edema in the shielded lungs. Lung irradiation alone not only increased pulmonary artery pressure and perivascular edema but also induced an increased LV relaxation time. Combined irradiation of lung and heart induced pronounced increases in LV end-diastolic pressure and relaxation time, in addition to an increase in right ventricle end-diastolic pressure, indicative of biventricular diastolic dysfunction. Moreover, enhanced pulmonary edema, inflammation and fibrosis were also observed. Conclusions: Both lung and heart irradiation cause cardiac and pulmonary toxicity via different mechanisms. Thus, when combined, the loss of cardiopulmonary performance is intensified further, explaining the deleterious effects of heart and lung coirradiation. Our findings show for the first time the physiological mechanism underlying the development of a multiorgan complication, RILT. Reduction of dose to either of these organs offers new opportunities to

  12. Postsystolic Shortening by Speckle Tracking Echocardiography Is an Independent Predictor of Cardiovascular Events and Mortality in the General Population

    DEFF Research Database (Denmark)

    Brainin, Philip; Biering-Sørensen, Sofie Reumert; Møgelvang, Rasmus

    2018-01-01

    ). The secondary end point was all-cause death. The postsystolic index (PSI) was defined as follows: [(maximum strain in cardiac cycle-peak systolic strain)/(maximum strain in cardiac cycle)]×100. PSS was regarded as present if PSI >20%. During a median follow-up of 11 years, 149 participants (12%) were diagnosed...... as having MACEs and 236 participants (18%) died. Increasing number of walls with PSS predicted both end points, an association that persisted after adjustment for age, sex, estimated glomerular filtration rate, global longitudinal strain, hypertension, heart rate, left ventricular ejection fraction, LV mass...... index, pro-B-type natriuretic peptide, previous ischemic heart disease, systolic blood pressure, average peak early diastolic longitudinal mitral annular velocity (e'), ratio between peak transmitral early and late diastolic inflow velocity (E/A), and left atrial volume index: MACEs (hazard ratio, 1...

  13. Gender-Based Differences in Cardiac Remodeling and ILK Expression after Myocardial Infarction

    International Nuclear Information System (INIS)

    Sofia, Renato Rodrigues; Serra, Andrey Jorge; Silva, Jose Antonio Jr; Antonio, Ednei Luiz; Manchini, Martha Trindade; Oliveira, Fernanda Aparecida Alves de; Teixeira, Vicente Paulo Castro; Tucci, Paulo José Ferreira

    2014-01-01

    Gender can influence post-infarction cardiac remodeling. To evaluate whether gender influences left ventricular (LV) remodeling and integrin-linked kinase (ILK) after myocardial infarction (MI). Female and male Wistar rats were assigned to one of three groups: sham, moderate MI (size: 20-39% of LV area), and large MI (size: ≥40% of LV area). MI was induced by coronary occlusion, and echocardiographic analysis was performed after six weeks to evaluate MI size as well as LV morphology and function. Real-time RT-PCR and Western blot were used to quantify ILK in the myocardium. MI size was similar between genders. MI resulted in systolic dysfunction and enlargement of end-diastolic as well as end-systolic dimension of LV as a function of necrotic area size in both genders. Female rats with large MI showed a lower diastolic and systolic dilatation than the respective male rats; however, LV dysfunction was similar between genders. Gene and protein levels of ILK were increased in female rats with moderate and large infarctions, but only male rats with large infarctions showed an altered ILK mRNA level. A negative linear correlation was evident between LV dimensions and ILK expression in female rats with large MI. Post-MI ILK expression is altered in a gender-specific manner, and higher ILK levels found in females may be sufficient to improve LV geometry but not LV function

  14. Application of MV/LV Transformers with OLTC for Increasing the PV Hosting Capacity Of LV Grids

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Heckmann, Wolfram; Geibel, Dominik

    2015-01-01

    The increased use of grid connected photovoltaic (PV) systems in low voltage (LV) grids also raises concern regarding the effects of these new generation units on the grid operation. Overvoltage in LV grids during high PV generation periods is one of the well-known effects caused by PV systems......) and the reactive power absorption by PV inverters, are investigated using field test results and simulations performed on the mentioned LV grid. The results show that the application of OLTC can effectively increase the PV hosting capacity of the grid......., which potentially can decrease the PV hosting capacity of electric grids. This paper presents the applications of medium voltage to low voltage (MV/LV) transformers with on-load tap changers (OLTCs) to prevent overvoltage in high PV penetration conditions. Autonomous methods for controlling...

  15. Restoration of optimal ellipsoid left ventricular geometry: lessons learnt from in silico surgical modelling.

    Science.gov (United States)

    Adhyapak, Srilakshmi M; Menon, Prahlad G; Rao Parachuri, V

    2014-02-01

    decreases following SVR. Both the regional end diastolic volume (EDV) and end systolic volume (ESV) at the apex decreased significantly corresponding to greater reductions in apical volumes by the technique of rectangular patch plasty (apical EDV 2.1607 ± 0.20577 to 0.4774 ± 0.1775 ml, P = 0.007; apical ESV 1.9708 ± 0.36451 to 0.442 ± 0.047 ml, P = 0.013). This pilot study was done using novel in silico techniques for virtual surgical modelling, which helped in accurate estimation and planning of optimal LV restoration by SVR.

  16. Relationship of radionuclide measurements of left ventricular diastolic filling in patients with type I diabetes mellitus to subsequent clinical cardiac disease

    International Nuclear Information System (INIS)

    Ohashi, K.; Gerson, M.C.; Khoury, J.C.; Fischer, E.A.; Smith, H.S.

    1990-01-01

    This paper evaluates left ventricular diastolic filling (LVDF) in patients with type I diabetes mellitus (DM) in order to identify increased risk for subsequent cardiac events. The authors obtained radionuclide ventriculograms in 54 patients with type I DM. Median follow-up for cardiac complications was 63 months. We assessed peak filling rate (PFR; in end diastolic volume [EDV] per second), first 1/2 filling fraction (1/2 FF), and first 1/2 filling fraction/R-R interval (1/2 FF/R-R) by analysis of convariance to account for effects of age and R-R interval. Cardiac complications ere found in 15 of 54 patients

  17. Prognostic value of CT-derived left atrial and left ventricular measures in patients with acute chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, University Medical Center Utrecht (Netherlands); Vliegenthart, Rozemarijn [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); University of Groningen/University Medical Center Groningen, Center for Medical Imaging − North East Netherlands, Department of Radiology, Groningen (Netherlands); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Nance, John W. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Bamberg, Fabian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Abro, Joseph A. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Carr, Christine M. [Division of Emergency Medicine, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Litwin, Sheldon E. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); and others

    2017-01-15

    Highlights: • LV mass and LA diameter are independent prognostic factor for composite MACE. • LV mass and LA diameter were not significant prognostic factors for MACE in African Americans. • Assessment of LV mass by CT may have a role in the management of patients. - Abstract: Purpose: To determine which left atrial (LA) and left ventricular (LV) parameters are associated with future major adverse cardiac event (MACE) and whether these measurements have independent prognostic value beyond risk factors and computed tomography (CT)-derived coronary artery disease measures. Materials and methods: This retrospective analysis was performed under an IRB waiver and in HIPAA compliance. Subjects underwent coronary CT angiography (CCTA) using a dual-source CT system for acute chest pain evaluation. LV mass, LV ejection fraction (EF), LV end-systolic volume (ESV) and LV end-diastolic volume (EDV), LA ESV and LA diameter, septal wall thickness and cardiac chamber diameters were measured. MACE was defined as cardiac death, non-fatal myocardial infarction, unstable angina, or late revascularization. The association between cardiac CT measures and the occurrence of MACE was quantified using Cox proportional hazard analysis. Results: 225 subjects (age, 56.2 ± 11.2; 140 males) were analyzed, of whom 42 (18.7%) experienced a MACE during a median follow-up of 13 months. LA diameter (HR:1.07, 95%CI:1.01–1.13 per mm) and LV mass (HR:1.05, 95%CI:1.00–1.10 per g) remained significant prognostic factor of MACE after controlling for Framingham risk score. LA diameter and LV mass were also found to have prognostic value independent of each other. The other morphologic and functional cardiac measures were no significant prognostic factors for MACE. Conclusion: CT-derived LA diameter and LV mass are associated with future MACE in patients undergoing evaluation for chest pain, and portend independent prognostic value beyond traditional risk factors, coronary calcium score, and

  18. Restrictive annuloplasty to treat functional mitral regurgitation: optimize the restriction to improve the results?

    Science.gov (United States)

    Totaro, Pasquale; Adragna, Nicola; Argano, Vincenzo

    2008-03-01

    Today, the 'gold standard' treatment of functional mitral regurgitation (MR) is the subject of much discussion. Although restrictive annuloplasty is currently considered the most reproducible technique, the means by which the degree of annular restriction is optimized remains problematic. The study was designed in order to identify whether the degree of restriction of the mitral annulus could influence early and midterm results following the treatment of functional MR using restrictive annuloplasty. A total of 32 consecutive patients with functional MR grade > or = 3+ was enrolled, among whom the mean anterior-posterior (AP) mitral annulus diameter was 39 +/- 3 mm. Restrictive mitral annuloplasty (combined with coronary artery bypass grafting) was performed in all patients using a Carpentier-Edwards Classic or Physio ring (size 26 or 28). The degree of AP annular restriction was calculated for each patient, and correlated with early and mid-term residual MR and left ventricular (LV) reverse remodeling (in terms of LV end-diastolic diameter (LVEDD) and LV end-diastolic volume (LVEDV) reduction). All surviving patients were examined at a one-year follow up. The mean AP mitral annulus restriction achieved was 48 +/- 4%. Intraoperatively, transesophageal echocardiography showed no residual MR in any patient. Before discharge from hospital, transthoracic echocardiography confirmed an absence of residual MR and showed significant LV reverse remodeling (LVEDV from 121 +/- 25 ml to 97 +/- 26 ml; LVEDD from 55 +/- 6 mm to 47 +/- 8 mm). A significant correlation (r = 0.57, p 40% of preoperative) appears to have a favorable influence on early postoperative LV reverse remodeling, and also allows for complete resolution of functional MR. In addition, 'no tolerance' of early residual MR seems to have a favorable influence on mid-term results, leading to a reduction in the one-year recurrence of significant MR.

  19. Impact of age and sex on normal left heart structure and function.

    Science.gov (United States)

    Hagström, Linn; Henein, Michael Y; Karp, Kjell; Waldenström, Anders; Lindqvist, Per

    2017-11-01

    Accurate age- and sex-related normal reference values of ventricular structure and function are important to determine the level of dysfunction in patients. The aim of this study therefore was to document normal age range sex-related measurements of LV structural and functional measurements to serve such purpose. We evaluated left ventricular structure and function in 293 healthy subjects between 20 and 90 years with equally distributed gender. Doppler echocardiography was used including measure of both systolic and diastolic functions. Due to systolic LV function, only long axis function correlated with age (r = 0·55, P<0·01) and the correlation was stronger in females. Concerning diastolic function, there was a strong age correlation in all parameters used (r = 0·40-0·74, P<0·001). Due to LV structural changes over age, females showed a larger reduction in end-diastolic volumes, but no or trivial difference in wall thickness after the age of 60 years. Age is associated with significant normal changes in left ventricular structure and function, which should be considered when deciding on normality. These changes are related to systemic arterial changes as well as body stature, thus reflecting overall body ageing process. Furthermore, normal cardiac ageing in females might partly explain the higher prevalence of heart failure with preserved ejection in females. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  20. Effect of preload reduction by hemodialysis on left atrial volume and echocardiographic Doppler parameters in patients with end-stage renal disease.

    Science.gov (United States)

    Barberato, Silvio H; Mantilla, Diego E V; Misocami, M Arcio; Gonçalves, Simone M; Bignelli, Alexandre T; Riella, Miguel C; Pecoits-Filho, Roberto

    2004-11-01

    Left atrial (LA) volume has been proposed as a less preload-dependent parameter of diastolic function than Doppler mitral inflow. We hypothesize that in the absence of mitral regurgitation and atrial fibrilation, LA enlargement could be a more practical (and relatively preload-independent) method for the evaluation of left ventricular diastolic function. The aim of the present study was to determine the effects of preload reduction by hemodialysis on LA volume.

  1. Vasodilator stress impairs the left ventricular function obtained with gated single-photon emission computed tomography in patients with known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    Odagiri, Keiichi; Uehara, Akihiko; Kurata, Chinori

    2010-01-01

    Transient ischemic dilatation (TID) and post-stress dysfunction of the left ventricle (LV) are important markers of severe coronary artery disease (CAD). To clarify the effects of stressor type on TID and post-stress LV dysfunction, changes in LV measurements were compared between patients with exercise- or vasodilator-induced stress. The 689 patients referred for technetium-99m tetrofosmin myocardial perfusion imaging were included. Patients were stressed with either a vasodilator (n=236) or exercise (n=453). LV measurements were obtained with electrocardiogram (ECG)-gated single photon emission computed tomography (SPECT). LV end-diastolic and end-systolic volume indexes (LVEDVI, LVESVI) increased and LV ejection fraction (LVEF) decreased after stress in the vasodilator-stress group. Vasodilator-stress and the summed difference score (SDS) were independent variables that decreased LVEF after stress. Even in patients without reversible defects, vasodilator-stress impaired LV function. There were no differences in the stress-to-rest ratios of LVEDVI (rEDV) and LVESVI (rESV) among patients with normal myocardial perfusion, fixed defects and reversible defects in the vasodilator-stress group, whereas in the exercise-stress group, rESV was significantly higher in the patients with reversible defects than in those without reversible defects. Within the vasodilator-stress group, neither rEDV nor rESV correlated with the SDS. Vasodilator-stress by itself decreases LVEF after stress. TID should be carefully interpreted when vasodilator-stress is used to detect severe CAD. (author)

  2. Safety and Efficacy of Transcatheter Closure of Patent Ductus Arteriosus With Severe Mitral Regurgitation in Adults.

    Science.gov (United States)

    Wang, Zhongkai; Chen, Tao; Chen, Liang; Qin, Yongwen; Zhao, Xianxian

    2016-01-01

    Transcatheter closure is the usual treatment for patent ductus arteriosus (PDA), but its safety and efficacy have not been reported in adult PDA patients with severe mitral regurgitation. A retrospective study on 27 consecutive patients diagnosed with PDA and severe mitral regurgitation and treated using transcatheter closure between September 2010 and September 2012 at the Department of Cardiology of Changhai Hospital in Changhai, China. Left ventricular (LV) diastolic volume and function, pulmonary artery pressure, and instantaneous reverse-flow volume were examined by echocardiography before PDA closure, immediately after closure, and 1 year after closure. After the procedure, the LV diastolic volume (P.05). Pulmonary arterial systolic pressure was unchanged 1 year after closure (from 46.41 ± 19.92 mm Hg to 45.43 ± 13.64 mm Hg; P=.58). All procedures were uneventful and only mild complications occurred (hemolysis in 2 cases, subcutaneous hematoma in 4 cases, and fever in 2 cases). Transcatheter closure can decrease the LV volume and instantaneous reverse-flow volume in adult PDA patients with severe mitral regurgitation. This procedure is effective and has a good safety profile.

  3. Patient-Specific MRI-Based Right Ventricle Models Using Different Zero-Load Diastole and Systole Geometries for Better Cardiac Stress and Strain Calculations and Pulmonary Valve Replacement Surgical Outcome Predictions.

    Directory of Open Access Journals (Sweden)

    Dalin Tang

    Full Text Available Accurate calculation of ventricular stress and strain is critical for cardiovascular investigations. Sarcomere shortening in active contraction leads to change of ventricular zero-stress configurations during the cardiac cycle. A new model using different zero-load diastole and systole geometries was introduced to provide more accurate cardiac stress/strain calculations with potential to predict post pulmonary valve replacement (PVR surgical outcome.Cardiac magnetic resonance (CMR data were obtained from 16 patients with repaired tetralogy of Fallot prior to and 6 months after pulmonary valve replacement (8 male, 8 female, mean age 34.5 years. Patients were divided into Group 1 (n = 8 with better post PVR outcome and Group 2 (n = 8 with worse post PVR outcome based on their change in RV ejection fraction (EF. CMR-based patient-specific computational RV/LV models using one zero-load geometry (1G model and two zero-load geometries (diastole and systole, 2G model were constructed and RV wall thickness, volume, circumferential and longitudinal curvatures, mechanical stress and strain were obtained for analysis. Pairwise T-test and Linear Mixed Effect (LME model were used to determine if the differences from the 1G and 2G models were statistically significant, with the dependence of the pair-wise observations and the patient-slice clustering effects being taken into consideration. For group comparisons, continuous variables (RV volumes, WT, C- and L- curvatures, and stress and strain values were summarized as mean ± SD and compared between the outcome groups by using an unpaired Student t-test. Logistic regression analysis was used to identify potential morphological and mechanical predictors for post PVR surgical outcome.Based on results from the 16 patients, mean begin-ejection stress and strain from the 2G model were 28% and 40% higher than that from the 1G model, respectively. Using the 2G model results, RV EF changes correlated negatively with

  4. Cardiac pathologies in female carriers of Duchenne muscular dystrophy assessed by cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schelhorn, Juliane; Schemuth, Haemi; Nensa, Felix; Nassenstein, Kai; Forsting, Michael; Schlosser, Thomas [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Schoenecker, Anne; Neudorf, Ulrich [University Hospital Essen, Department of Pediatric Cardiology, Essen (Germany); Schara, Ulrike [University Hospital Essen, Department of Pediatric Neurology, Essen (Germany)

    2015-10-15

    Duchenne muscular dystrophy (DMD) is the most common and severe dystrophinopathy. DMD carriers rarely present with clinical symptoms, but may suffer from cardiac involvement. Because echocardiographic findings are inconsistent and cardiac magnetic resonance imaging (CMRI) data are limited, this study sought to investigate asymptomatic carriers for cardiac abnormalities using CMRI. Fifteen genetically confirmed DMD carriers (age, 32.3 ± 10.2 years) were prospectively examined on a 1.5T MR system. Cine, T2, and late-gadolinium-enhanced (LGE) images were acquired, and were evaluated in consensus by two experienced readers. Left ventricular (LV) parameters were analysed semiautomatically, normalized to BSA. Normalized LV end-diastolic volume was increased in 7 % (73.7 ± 16.8 ml/m{sup 2}; range, 48-116 ml/m{sup 2}) and normalized LV end-systolic volume in 20 % (31.5 ± 13.3 ml/m{sup 2}; range, 15-74 ml/m{sup 2}). EF was reduced in 33 % (58.4 ± 7.6 %; range, 37-69 %) and normalized LV myocardial mass in 80 % (40.5 ± 6.8 g/m{sup 2}; range, 31-55 g/m{sup 2}). In 80 %, regional myocardial thinning was detected in more than one segment. In 13 % and 40 %, apical-lateral accentuation of LV non-compaction was present. LGE was found in 60 % (midmyocardial inferolateral accentuation). Given the high frequency of cardiac pathologies detected by CMRI, regular cardiac risk assessment is advisable for DMD carriers. Besides clinical examination, CMRI is an excellent tool for this purpose. (orig.)

  5. Improved approach to quantitative cardiac volumetrics using automatic thresholding and manual trimming: a cardiovascular MRI study.

    Science.gov (United States)

    Rayarao, Geetha; Biederman, Robert W W; Williams, Ronald B; Yamrozik, June A; Lombardi, Richard; Doyle, Mark

    2018-01-01

    To establish the clinical validity and accuracy of automatic thresholding and manual trimming (ATMT) by comparing the method with the conventional contouring method for in vivo cardiac volume measurements. CMR was performed on 40 subjects (30 patients and 10 controls) using steady-state free precession cine sequences with slices oriented in the short-axis and acquired contiguously from base to apex. Left ventricular (LV) volumes, end-diastolic volume, end-systolic volume, and stroke volume (SV) were obtained with ATMT and with the conventional contouring method. Additionally, SV was measured independently using CMR phase velocity mapping (PVM) of the aorta for validation. Three methods of calculating SV were compared by applying Bland-Altman analysis. The Bland-Altman standard deviation of variation (SD) and offset bias for LV SV for the three sets of data were: ATMT-PVM (7.65, [Formula: see text]), ATMT-contours (7.85, [Formula: see text]), and contour-PVM (11.01, 4.97), respectively. Equating the observed range to the error contribution of each approach, the error magnitude of ATMT:PVM:contours was in the ratio 1:2.4:2.5. Use of ATMT for measuring ventricular volumes accommodates trabeculae and papillary structures more intuitively than contemporary contouring methods. This results in lower variation when analyzing cardiac structure and function and consequently improved accuracy in assessing chamber volumes.

  6. Correlation of trabeculae and papillary muscles with clinical and cardiac characteristics and impact on CMR measures of LV anatomy and function

    NARCIS (Netherlands)

    Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L T F; Salton, Carol J.; Blease, Susan J.; Yeon, Susan B.; Breeuwer, Marcel; O'Donnell, Christopher J.; Manning, Warren J.

    2012-01-01

    Objectives: The goal of this study was to assess the relationship of left ventricular (LV) trabeculae and papillary muscles (TPM) with clinical characteristics in a community-based, free-living adult cohort and to determine the effect of TPM on quantitative measures of LV volume, mass, and ejection

  7. Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT. Can we use the same reference database?

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Yamaguchi, Hitoshi; Tsujimura, Eiichiro; Nishimura, Tsunehiko [Osaka Univ., Suita (Japan). Graduate School of Medicine

    2000-04-01

    The purpose of this study was to compare left ventricular (LV) volume and ejection fraction (LVEF) measurements obtained with electrocardiographic gated single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (GS-MPI) with those obtained with gated SPECT cardiac blood-pool imaging (GS-pool). Fifteen patients underwent GS-MPI with technetium-99m tetrofosmin and GS-pool with technetium-99m-erythrocyte, within a mean interval of 8{+-}3 days. Eight patients had suspected dilated cardiomyopathy and seven patients had angiographically significant coronary artery disease. End-diastolic volume (EDV), end-systolic volume (ESV) and LVEF measurements were estimated from GS-MPI images by means of Cedars-Sinai automatic quantitative program and from GS-pool images by the threshold technique. Mean differences between GS-MPI and GS-pool in EDV, ESV and LVEF measurements were -2.8{+-}10.5 ml [95% confidence interval (CI): -8.6{+-}3.0 ml], 2.6{+-}7.3 ml (CI: -1.4-6.6 ml) and -2.3{+-}5.1% (CI: -5.1-0.6%), respectively. No significant difference in the mean differences from 0 was found for EDV, ESV or LVEF measurements. Bland-Altman plots revealed no trend over the measured LV volumes and LVEF. For all parameters, regression lines approximated lines of identity. The excellent agreement between GS-MPI and GS-pool measurements suggests that, for estimation of LV volumes and LVEF, these two techniques may be used interchangeably and measurements by one method can serve as a reference for the other. (author)

  8. Current distribution in LV networks during 1-phase MV short-circuit

    NARCIS (Netherlands)

    Waes, van J.B.M.; Provoost, F.; Merwe, van der J.; Cobben, J.F.G.; Deursen, van A.P.J.; van Riet, M.J.M.; Laan, van der P.C.T.

    2000-01-01

    This paper describes the consequences of a fault in a medium voltage network on the grounding systems at the LV-side. To study the current distribution and to verify the models, we deliberately introduced one phase to ground faults in the 10 kV floating MV network. The selected site was the end of a

  9. Heart failure: when form fails to follow function.

    Science.gov (United States)

    Katz, Arnold M; Rolett, Ellis L

    2016-02-01

    Cardiac performance is normally determined by architectural, cellular, and molecular structures that determine the heart's form, and by physiological and biochemical mechanisms that regulate the function of these structures. Impaired adaptation of form to function in failing hearts contributes to two syndromes initially called systolic heart failure (SHF) and diastolic heart failure (DHF). In SHF, characterized by high end-diastolic volume (EDV), the left ventricle (LV) cannot eject a normal stroke volume (SV); in DHF, with normal or low EDV, the LV cannot accept a normal venous return. These syndromes are now generally defined in terms of ejection fraction (EF): SHF became 'heart failure with reduced ejection fraction' (HFrEF) while DHF became 'heart failure with normal or preserved ejection fraction' (HFnEF or HFpEF). However, EF is a chimeric index because it is the ratio between SV--which measures function, and EDV--which measures form. In SHF the LV dilates when sarcomere addition in series increases cardiac myocyte length, whereas sarcomere addition in parallel can cause concentric hypertrophy in DHF by increasing myocyte thickness. Although dilatation in SHF allows the LV to accept a greater venous return, it increases the energy cost of ejection and initiates a vicious cycle that contributes to progressive dilatation. In contrast, concentric hypertrophy in DHF facilitates ejection but impairs filling and can cause heart muscle to deteriorate. Differences in the molecular signals that initiate dilatation and concentric hypertrophy can explain why many drugs that improve prognosis in SHF have little if any benefit in DHF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  10. Diagnostic and Prognostic Value of Long-Axis Strain and Myocardial Contraction Fraction Using Standard Cardiovascular MR Imaging in Patients with Nonischemic Dilated Cardiomyopathies.

    Science.gov (United States)

    Arenja, Nisha; Riffel, Johannes H; Fritz, Thomas; André, Florian; Aus dem Siepen, Fabian; Mueller-Hennessen, Matthias; Giannitsis, Evangelos; Katus, Hugo A; Friedrich, Matthias G; Buss, Sebastian J

    2017-06-01

    Purpose To assess the utility of established functional markers versus two additional functional markers derived from standard cardiovascular magnetic resonance (MR) images for their incremental diagnostic and prognostic information in patients with nonischemic dilated cardiomyopathy (NIDCM). Materials and Methods Approval was obtained from the local ethics committee. MR images from 453 patients with NIDCM and 150 healthy control subjects were included between 2005 and 2013 and were analyzed retrospectively. Myocardial contraction fraction (MCF) was calculated by dividing left ventricular (LV) stroke volume by LV myocardial volume, and long-axis strain (LAS) was calculated from the distances between the epicardial border of the LV apex and the midpoint of a line connecting the origins of the mitral valve leaflets at end systole and end diastole. Receiver operating characteristic curve, Kaplan-Meier method, Cox regression, and classification and regression tree (CART) analyses were performed for diagnostic and prognostic performances. Results LAS (area under the receiver operating characteristic curve [AUC] = 0.93, P < .001) and MCF (AUC = 0.92, P < .001) can be used to discriminate patients with NIDCM from age- and sex-matched control subjects. A total of 97 patients reached the combined end point during a median follow-up of 4.8 years. In multivariate Cox regression analysis, only LV ejection fraction (EF) and LAS independently indicated the combined end point (hazard ratio = 2.8 and 1.9, respectively; P < .001 for both). In a risk stratification approach with classification and regression tree analysis, combined LV EF and LAS cutoff values were used to stratify patients into three risk groups (log-rank test, P < .001). Conclusion Cardiovascular MR-derived MCF and LAS serve as reliable diagnostic and prognostic markers in patients with NIDCM. LAS, as a marker for longitudinal contractile function, is an independent parameter for outcome and offers incremental

  11. Matrix metalloproteinases and left ventricular function and structure in spinal cord injured subjects.

    Science.gov (United States)

    Schreiber, Roberto; Paim, Layde R; de Rossi, Guilherme; Matos-Souza, José R; Costa E Silva, Anselmo de A; Souza, Cristiane M; Borges, Mariane; Azevedo, Eliza R; Alonso, Karina C; Gorla, José I; Cliquet, Alberto; Nadruz, Wilson

    2014-11-01

    Subjects with spinal cord injury (SCI) exhibit impaired left ventricular (LV) diastolic function, which has been reported to be attenuated by regular physical activity. This study investigated the relationship between circulating matrix metalloproteinases (MMPs) and tissue inhibitors of MMPs (TIMPs) and echocardiographic parameters in SCI subjects and the role of physical activity in this regard. Forty-two men with SCI [19 sedentary (S-SCI) and 23 physically-active (PA-SCI)] were evaluated by clinical, anthropometric, laboratory, and echocardiographic analysis. Plasmatic pro-MMP-2, MMP-2, MMP-8, pro-MMP-9, MMP-9, TIMP-1 and TIMP-2 levels were determined by enzyme-linked immunosorbent assay and zymography. PA-SCI subjects presented lower pro-MMP-2 and pro-MMP-2/TIMP-2 levels and improved markers of LV diastolic function (lower E/Em and higher Em and E/A values) than S-SCI ones. Bivariate analysis showed that pro-MMP-2 correlated inversely with Em and directly with E/Em, while MMP-9 correlated directly with LV mass index and LV end-diastolic diameter in the whole sample. Following multiple regression analysis, pro-MMP-2, but not physical activity, remained associated with Em, while MMP-9 was associated with LV mass index in the whole sample. These findings suggest differing roles for MMPs in LV structure and function regulation and an interaction among pro-MMP-2, diastolic function and physical activity in SCI subjects. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke (Toyama Medical and Pharmaceutical Univ. (Japan))

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  13. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke [Toyama Medical and Pharmaceutical Univ. (Japan)

    1993-09-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author).

  14. Measurement of left ventricular volume by biplane cine magnetic resonance imaging in children

    International Nuclear Information System (INIS)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Murakami, Arata; Futatsuya, Ryuusuke

    1993-01-01

    To determine the ability of cine magnetic resonance imaging (MRI) to assess left ventricular (LV) volumes, we studied 20 children (age 4 months to 10 years) with various heart disease, validated by comparison with biplane LV angiography. Previous MRI studies to assess LV volumes have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using biplane cine MRI and planes aligned with the true cardiac axes (the intrinsic long and short axis) of the LV was developed in views comparable with biplane LV angiography. In all patients, LV volumes were calculated by a Simpson's rule algorithm, both in MRI and LV angiography. MRI determined LV volumes were slightly underestimated but correlated reasonably well with angiographic values (LVEDV: Y=0.88X + 1.58, R=0.98, LVESV: Y=0.72X + 1.02, R=0.98). Especially, even in the patients who have abnormal left ventricular geometry such as Tetralogy of Fallot, MRI determined LV volumes correlated well with angiographic values. It is concluded that biplane cine MRI, using the intrinsic LV long and short axis planes, permits noninvasive assessment of LV volumes in views comparable to standard angiographic projections and appears practical for clinical use in childhood heart disease, because the scan and analysis time are relatively short. (author)

  15. Cardiac MRI: evaluation of phonocardiogram-gated cine imaging for the assessment of global und regional left ventricular function in clinical routine

    International Nuclear Information System (INIS)

    Nassenstein, Kai; Schlosser, Thomas; Orzada, Stephan; Haering, Lars; Czylwik, Andreas; Zenge, Michael; Mueller, Edgar; Eberle, Holger; Bruder, Oliver; Ladd, Mark E.; Maderwald, Stefan

    2012-01-01

    To validate a phonocardiogram (PCG)-gated cine imaging approach for the assessment of left ventricular (LV) function. In this prospective study, cine MR imaging of the LV was performed twice in 79 patients by using retrospectively PCG- and retrospectively ECG-gated cine SSFP sequences at 1.5 T. End-diastolic volumes (EDV), end-systolic volumes (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM), as well as regional wall motion were assessed. Subgroup analyses were performed for patients with valvular defects and for patients with dysrhythmia. PCG-gated imaging was feasible in 75 (95%) patients, ECG-gating in all patients. Excellent correlations were observed for all volumetric parameters (r > 0.98 for all variables analysed). No significant differences were observed for EDV (-0.24 ± 3.14 mL, P = 0.5133), ESV (-0.04 ± 2.36 mL, P = 0.8951), SV (-0.20 ± 3.41 mL, P = 0.6083), EF (-0.16 ± 1.98%, P = 0.4910), or MM (0.31 ± 4.2 g, P = 0.7067) for the entire study cohort, nor for either of the subgroups. PCG- and ECG-gated cine imaging revealed similar results for regional wall motion analyses (115 vs. 119 segments with wall motion abnormalities, P = 0.3652). The present study demonstrates that PCG-gated cine imaging enables accurate assessment of global and regional LV function in the vast majority of patients in clinical routine. (orig.)

  16. Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR.

    Science.gov (United States)

    Hippeläinen, Eero; Mäkelä, Teemu; Kaasalainen, Touko; Kaleva, Erna

    2017-12-01

    Developments in single photon emission tomography instrumentation and reconstruction methods present a potential for decreasing acquisition times. One of such recent options for myocardial perfusion imaging (MPI) is IQ-SPECT. This study was motivated by the inconsistency in the reported ejection fraction (EF) and left ventricular (LV) volume results between IQ-SPECT and more conventional low-energy high-resolution (LEHR) collimation protocols. IQ-SPECT and LEHR quantitative results were compared while the equivalent number of iterations (EI) was varied. The end-diastolic (EDV) and end-systolic volumes (ESV) and the derived EF values were investigated. A dynamic heart phantom was used to produce repeatable ESVs, EDVs and EFs. Phantom performance was verified by comparing the set EF values to those measured from a gated multi-slice X-ray computed tomography (CT) scan (EF True ). The phantom with an EF setting of 45, 55, 65 and 70% was imaged with both IQ-SPECT and LEHR protocols. The data were reconstructed with different EI, and two commonly used clinical myocardium delineation software were used to evaluate the LV volumes. The CT verification showed that the phantom EF settings were repeatable and accurate with the EF True being within 1% point from the manufacture's nominal value. Depending on EI both MPI protocols can be made to produce correct EF estimates, but IQ-SPECT protocol produced on average 41 and 42% smaller EDV and ESV when compared to the phantom's volumes, while LEHR protocol underestimated volumes by 24 and 21%, respectively. The volume results were largely similar between the delineation methods used. The reconstruction parameters can greatly affect the volume estimates obtained from perfusion studies. IQ-SPECT produces systematically smaller LV volumes than the conventional LEHR MPI protocol. The volume estimates are also software dependent.

  17. Measuring Regional Changes in the Diastolic Deformation of the Left Ventricle of SHR Rats Using microPET Technology and Hyperelastic Warping

    International Nuclear Information System (INIS)

    Gullberg, Grant T; VERESS, ALEXANDER I.; WEISS, JEFFREY A.; HUESMAN, RONALD H.; REUTTER, BRYAN W.; TAYLOR, SCOTT E.; SITEK, AREK; FENG, BING; YANG, YONGFENG; GULLBERG, GRANT T.

    2008-01-01

    The objective of this research was to assess applicability of a technique known as hyperelastic warping for the measurement of local strains in the left ventricle (LV) directly from microPET image data sets. The technique uses differences in image intensities between template (reference) and target (loaded) image data sets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target images. For validation, the template image was defined as the end-systolic microPET image data set from a Wistar Kyoto (WKY) rat. The target image was created by mapping the template image using the deformation results obtained from a FE model of diastolic filling. Regression analysis revealed highly significant correlations between the simulated forward FE solution and image derived warping predictions for fiber stretch (R2 = 0.96), circumferential strain (R2 = 0.96), radial strain (R2 = 0.93), and longitudinal strain (R2 = 0.76) (p < 0.001 for all cases). The technology was applied to microPET image data of two spontaneously hypertensive rats (SHR) and a WKY control. Regional analysis revealed that, the lateral freewall in the SHR subjects showed the greatest deformation compared with the other wall segments. This work indicates that warping can accurately predict the strain distributions during diastole from the analysis of microPET data sets

  18. Measuring Regional Changes in the Diastolic Deformation of the Left Ventricle of SHR Rats Using microPET Technology and Hyperelastic Warping

    Energy Technology Data Exchange (ETDEWEB)

    Gullberg, Grant T; VERESS , ALEXANDER I.; WEISS, JEFFREY A.; HUESMAN, RONALD H.; REUTTER, BRYAN W.; TAYLOR , SCOTT E.; SITEK , AREK; FENG, BING; YANG , YONGFENG; GULLBERG, GRANT T.

    2008-04-04

    The objective of this research was to assess applicability of a technique known as hyperelastic warping for the measurement of local strains in the left ventricle (LV) directly from microPET image data sets. The technique uses differences in image intensities between template (reference) and target (loaded) image data sets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target images. For validation, the template image was defined as the end-systolic microPET image data set from a Wistar Kyoto (WKY) rat. The target image was created by mapping the template image using the deformation results obtained from a FE model of diastolic filling. Regression analysis revealed highly significant correlations between the simulated forward FE solution and image derived warping predictions for fiber stretch (R2 = 0.96), circumferential strain (R2 = 0.96), radial strain (R2 = 0.93), and longitudinal strain (R2 = 0.76) (p<0.001for all cases). The technology was applied to microPET image data of two spontaneously hypertensive rats (SHR) and a WKY control. Regional analysis revealed that, the lateral freewall in the SHR subjects showed the greatest deformation compared with the other wall segments. This work indicates that warping can accurately predict the strain distributions during diastole from the analysis of microPET data sets.

  19. Impact of Valvuloarterial Impedance on Concentric Remodeling in Aortic Stenosis and Its Regression after Valve Replacement.

    Science.gov (United States)

    Jang, Jeong Yoon; Seo, Jeong-Sook; Sun, Byung Joo; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan

    2016-09-01

    Left ventricle (LV) in patients with aortic stenosis (AS) faces a double hemodynamic load incorporating both valvular stenosis and reduced systemic arterial compliance (SAC). This study aimed to evaluate the impact of global LV afterload on LV hypertrophy (LVH) before and after aortic valve replacement (AVR). The study cohort included 453 patients (247 males; mean age, 64 ± 11 years) who underwent AVR. Pre- and post-AVR echocardiographic examinations were retrospectively analyzed including an index of valvuloarterial impedance (Z VA ) and LV mass index/LV end-diastolic volume index (LVMI/LVEDVI) as a parameter of LVH. Pre-AVR LVMI/LVEDVI was 2.7 ± 0.9 g/mL with an aortic valve area (AVA) of 0.6 ± 0.2 cm 2 . Z VA was 5.9 ± 1.9 mm Hg/mL/m 2 and showed a stronger correlation (β = 0.601, p regression in 322 patients with follow-up duration >1 year after AVR. Z VA is a major determinant of concentric remodeling in AS before AVR and LVH regression after AVR, which should be incorporated in routine evaluation of AS.

  20. Left ventricular dysfunction in repaired tetralogy of Fallot: incidence and impact on atrial arrhythmias at long term-follow up.

    Science.gov (United States)

    Ait Ali, Lamia; Trocchio, GianLuca; Crepaz, Roberto; Stuefer, Josef; Stagnaro, Nicola; Siciliano, Valeria; Molinaro, Sabrina; Sicari, Rosa; Festa, Pierluigi

    2016-09-01

    Left ventricle (LV) systolic dysfunction in repaired tetralogy of Fallot (TOF) has been identified as a risk factor for functional status and adverse outcome. The aims of this cross-sectional followed by a prospective study were: (1) to evaluate the prevalence of LV systolic dysfunction in a large cohort of adults with repaired tetralogy of Fallot, (2) to test the relationship between LV systolic dysfunction and other known risk factors and (3) to evaluate the impact of LV systolic dysfunction on adverse cardiac events. In a multicenter study, 237 adults repaired TOF (58 % males, age 30 ± 10 years) were evaluated by cardiac magnetic resonance (CMR). Demographics, surgical history, ECG, Echo-Color Doppler and follow-up data were recorded. LV was dilated (Z value >2) in 16 patients (6 %), however 56 patients (23.6 %) had a reduced LV systolic function left ventricle ejection fraction (LVEF) (Z value <-2). Patients with LV systolic dysfunction were mainly males (82 %), had reduced right ventricle ejection fraction (RVEF), and higher right and left Late Gadolinium Enhanced scores. In a multivariate regression analysis male gender and RVEF resulted to be independent factors associated to LV systolic dysfunction. Atrial arrhythmias were the main adverse cardiac event at the follow-up and were associated to higher biventricular volumes and lower biventricular ejection fraction (EF); however multivariable analysis identified age, right ventricle end-diastolic volume (RVEDVi) and tricuspid regurgitation as independents factors associated to atrial arrhythmias. At long term follow-up at least ¼ of repaired TOF has LV dysfunction. Lower LVEF is associated to male gender and lower RVEF.

  1. Left ventricular volume analysis as a basic tool to describe cardiac function.

    Science.gov (United States)

    Kerkhof, Peter L M; Kuznetsova, Tatiana; Ali, Rania; Handly, Neal

    2018-03-01

    The heart is often regarded as a compression pump. Therefore, determination of pressure and volume is essential for cardiac function analysis. Traditionally, ventricular performance was described in terms of the Starling curve, i.e., output related to input. This view is based on two variables (namely, stroke volume and end-diastolic volume), often studied in the isolated (i.e., denervated) heart, and has dominated the interpretation of cardiac mechanics over the last century. The ratio of the prevailing coordinates within that paradigm is termed ejection fraction (EF), which is the popular metric routinely used in the clinic. Here we present an insightful alternative approach while describing volume regulation by relating end-systolic volume (ESV) to end-diastolic volume. This route obviates the undesired use of metrics derived from differences or ratios, as employed in previous models. We illustrate basic principles concerning ventricular volume regulation by data obtained from intact animal experiments and collected in healthy humans. Special attention is given to sex-specific differences. The method can be applied to the dynamics of a single heart and to an ensemble of individuals. Group analysis allows for stratification regarding sex, age, medication, and additional clinically relevant covariates. A straightforward procedure derives the relationship between EF and ESV and describes myocardial oxygen consumption in terms of ESV. This representation enhances insight and reduces the impact of the metric EF, in favor of the end-systolic elastance concept advanced 4 decades ago.

  2. Significant correlation of P-wave parameters with left atrial volume index and left ventricular diastolic function.

    Science.gov (United States)

    Tsai, Wei-Chung; Lee, Kun-Tai; Wu, Ming-Tsang; Chu, Chih-Sheng; Lin, Tsung-Hsien; Hsu, Po-Chao; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2013-07-01

    The 12-lead electrocardiogram (ECG) is a commonly used tool to access left atrial enlargement, which is a marker of left ventricular diastolic dysfunction (LVDD). The aim of this study was to evaluate any association of the P-wave measurements in ECG with left atrial volume (LAV) index and LVDD. This study enrolled 270 patients. In this study, 4 ECG P-wave parameters corrected by heart rate, that is, corrected P-wave maximum duration (PWdurMaxC), corrected P-wave dispersion (PWdisperC), corrected P-wave area (PWareaC) and corrected mean P-wave duration (meanPWdurC), were measured. LAV and left ventricular diastolic parameters were measured from echocardiography. LVDD was defined as a pseudonormal or restrictive mitral inflow pattern. The 4 P-wave parameters were significantly correlated with the LAV index after adjusting for age, sex, diabetes, hypertension, coronary artery disease, body mass index and diastolic blood pressure in multivariate analysis. The standardized β coefficients of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 0.338, 0.298, 0.215 and 0.296, respectively. The 4 P-wave parameters were also significantly correlated with LVDD after multivariate logistic regression analysis. The odds ratios (95% confidence intervals) of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 1.03 (1.01-1.04), 1.02 (1.04-1.04), 1.04 (1.02-1.07) and 1.01 (1.00-1.02), respectively. This study demonstrated that PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were important determinants of the LAV index and LVDD. Therefore, screening patients by means of the 12-lead ECG may be helpful in identifying a high-risk group of increased LAV index and LVDD.

  3. Ia diastolic dysfunction: an echocardiographic grade.

    Science.gov (United States)

    Pandit, Anil; Mookadam, Farouk; Hakim, Fayaz A; Mulroy, Eoin; Saadiq, Rayya; Doherty, Mairead; Cha, Stephen; Seward, James; Wilansky, Susan

    2015-01-01

    To demonstrate that a distinct group of patients with Grade Ia diastolic dysfunction who do not conform to present ASE/ESE diastolic grading exists. Echocardiographic and demographic data of the Grade Ia diastolic dysfunction were extracted and compared with that of Grades I and II in 515 patients. The mean of age of the cohort was 75 ± 9 years and body mass index did not differ significantly between the 3 groups (P = 0.45). Measurements of left atrial volume index (28.58 ± 7 mL/m(2) in I, 33 ± 10 mL/m(2) in Ia, and 39 ± 12 mL/m(2) in II P Ia, and 79 ± 15 msec in II P Ia, and 217 ± 57 msec in II P Ia, and 22 ± 8 in II), and lateral E/e' (8 ± 3 in I, 15 ± 6 in Ia, and 18 ± 9 in II P Ia compared with I and II. These findings remained significant even after adjusting for age, gender, diabetes, and smoking. Patients with echocardiographic characteristics of relaxation abnormality (E/A ratio of Ia group. © 2014, Wiley Periodicals, Inc.

  4. Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging.

    Science.gov (United States)

    Kido, Tomoyuki; Kido, Teruhito; Nakamura, Masashi; Watanabe, Kouki; Schmidt, Michaela; Forman, Christoph; Mochizuki, Teruhito

    2017-09-25

    Compressed sensing (CS) cine magnetic resonance imaging (MRI) has the advantage of being inherently insensitive to respiratory motion. This study compared the accuracy of free-breathing (FB) CS and breath-hold (BH) standard cine MRI for left ventricular (LV) volume assessment.Methods and Results:Sixty-three patients underwent cine MRI with both techniques. Both types of images were acquired in stacks of 8 short-axis slices (temporal/spatial resolution, 41 ms/1.7×1.7×6 mm 3 ) and compared for ejection fraction, end-diastolic and systolic volumes, stroke volume, and LV mass. Both BH standard and FB CS cine MRI provided acceptable image quality for LV volumetric analysis (score ≥3) in all patients (4.7±0.5 and 3.7±0.5, respectively; Pcine MRI (median, IQR: BH standard, 83.8 mL, 64.7-102.7 mL; FB CS, 79.0 mL, 66.0-101.0 mL; P=0.0006). The total acquisition times for BH standard and FB CS cine MRI were 113±7 s and 24±4 s, respectively (Pcine MRI is a clinically useful alternative to BH standard cine MRI in patients with impaired BH capacity.

  5. Hemodynamic and respiratory factors that influence the opening of patent foramen ovale in mechanically ventilated patients.

    Science.gov (United States)

    Vavlitou, A; Minas, G; Zannetos, S; Kyprianou, T; Tsagourias, M; Matamis, D

    2016-01-01

    Patent foramen ovale (PFO) is an anatomic variant that may lead to several pathological conditions, notably right to left shunt, paradoxical embolism, hypoxemia, and cerebral fat embolism. Mechanical positive pressure ventilation may increase the prevalence of PFO opening in Intensive Care Unit (ICU) patients; however, the respiratory and hemodynamic determinants of PFO opening have been poorly investigated. Contrast-enhanced transesophageal echocardiogram (ce-TEE) is considered the gold standard for PFO detection. We prospectively performed a multicenter study using ce-TEE in order to determine the respiratory and hemodynamic factors that may lead to PFO opening. One hundred and eight consecutive ICU adult patients under mechanical ventilation from three tertiary care hospitals, were included in the study. A standard multiplane ce-TEE was performed, and the dimensions and function of the right and left ventricle were studied. In each patient, the right ventricle (RV) end-diastolic area, RV end-systolic area, left ventricle (LV) end-diastolic area, and LV ejection fraction were measured using the modified Simpson's rule and the four-chamber view. At least three bubble tests were performed to detect PFO opening. Ventilatory parameters such as tidal volume, plateau pressure, static lung compliance, and positive end-expiratory pressure were recorded during the bubble test. Data for 81 men and 27 women were analyzed. PFO was detected in 27 % of the study population. Statistical significance was found between the presence of PFO and plateau pressure (odds ratio 3.421, 95 % CI: 1.2-9.4, p =0.017). Additionally, the presence of right ventricular dilatation (RV>LV) was strongly associated with PFO opening (odds ratio 3.163, 95 % CI: 1.2-8.075, p =0.018). In this group of mechanically ventilated, critically ill adult patients, right ventricular dilatation and plateau pressure above 26 mmHg were significantly associated with foramen ovale opening. Hippokratia 2016, 20

  6. Biventricular MR volumetric analysis and MR flow quantification in the ascending aorta and pulmonary trunk for quantification of valvular regurgitation

    International Nuclear Information System (INIS)

    Rominger, M.B.

    2004-01-01

    Purpose: To test the value of biventricular volumetric analysis and the combination of biventricular volumetric analysis with flow quantification in the ascending aorta (Ao) and pulmonary trunk (Pu) for quantification of regurgitation volume and cardiac function in valvular regurgitation (VR) according to location and presence of single or multivalvular disease. Materials and Methods: In 106 patients, the stroke volumes were assessed by measuring the biventricular volumes and the forward-stroke volumes in the great and small circulation by measuring the flow in the Ao and Pu. Valve regurgitation volumes and quotients were calculated for single and multivalvular disease and correlated with semiquantitative 2D-echocardiography (grade I-IV). For the assessment of the cardiac function in VR, the volumetric parameters of ejection fraction and end-diastolic (EDV) and end-systolic (ESV) volumes were determined. Results: The detection rate was 49% for left ventricular (LV) VR and 42% for right ventricular (RV) VR. Low LV VR and RV VR usually could not be detected quantitatively, with the detection rate improving with echocardiographically higher insufficiency grades. Quantitative MRI could detect a higher grade solitary aortic valve insufficiency (≥2) in 11 of 12 patients and higher grade mitral valve insufficiency in 4 of 10 patients. A significant increase in RV and LV ventricular EDV and ESV was seen more often with increased MR regurgitation volumes. Aortic stenosis did not interfere with flow measurements in the Ao. Conclusions: Biventricular volumetry combined with flow measurements in Ao and Pu is a robust, applicable and simple method to assess higher grade regurgitation volumes and the cardiac function in single and multivalvular regurgitation at different locations. It is an important application for the diagnosis of VR by MRI [de

  7. Cardiopulmonary physiology: why the heart and lungs are inextricably linked.

    Science.gov (United States)

    Verhoeff, Kevin; Mitchell, Jamie R

    2017-09-01

    Because the heart and lungs are confined within the thoracic cavity, understanding their interactions is integral for studying each system. Such interactions include changes in external constraint to the heart, blood volume redistribution (venous return), direct ventricular interaction (DVI), and left ventricular (LV) afterload. During mechanical ventilation, these interactions can be amplified and result in reduced cardiac output. For example, increased intrathoracic pressure associated with mechanical ventilation can increase external constraint and limit ventricular diastolic filling and, therefore, output. Similarly, high intrathoracic pressures can alter blood volume distribution and limit diastolic filling of both ventricles while concomitantly increasing pulmonary vascular resistance, leading to increased DVI, which may further limit LV filling. While LV afterload is generally considered to decrease with increased intrathoracic pressure, the question arises if the reduced LV afterload is primarily a consequence of a reduced LV preload. A thorough understanding of the interaction between the heart and lungs can be complicated but is essential for clinicians and health science students alike. In this teaching review, we have attempted to highlight the present understanding of certain salient aspects of cardiopulmonary physiology and pathophysiology, as well as provide a resource for multidisciplined health science educators and students. Copyright © 2017 the American Physiological Society.

  8. IGF-1 Prevents Diastolic and Systolic Dysfunction Associated with Cardiomyopathy and Preserves Adrenergic Sensitivity

    Science.gov (United States)

    Roof, Steve R.; Boslett, James; Russell, Duncan; del Rio, Carlos; Alecusan, Joe; Zweier, Jay L.; Ziolo, Mark T.; Hamlin, Robert; Mohler, Peter J.; Curran, Jerry

    2015-01-01

    Aims Insulin-like growth factor 1 (IGF-1)-dependent signaling promotes exercise-induced physiological cardiac hypertrophy. However, the in vivo therapeutic potential of IGF-1 for heart disease is not well established. Here we test the potential therapeutic benefits of IGF-1 on cardiac function using an in vivo model of chronic catecholamine-induced cardiomyopathy. Methods Rats were perfused with isoproterenol via osmotic pump (1 mg/kg/day) and treated with 2 mg/kg IGF-1 (2 mg/kg/day, 6 days a week) for 2 or 4 weeks. Echocardiography, ECG, and blood pressure were assessed. In vivo pressure-volume loop studies were conducted at 4 weeks. Heart sections were analyzed for fibrosis and apoptosis, and relevant biochemical signaling cascades were assessed. Results After 4 weeks, diastolic function (EDPVR, EDP, tau, E/A ratio), systolic function (PRSW, ESPVR, dP/dtmax), and structural remodeling (LV chamber diameter, wall thickness) were all adversely affected in isoproterenol-treated rats. All these detrimental effects were attenuated in rats treated with Iso+IGF-1. Isoproterenol-dependent effects on BP were attenuated by IGF-1 treatment. Adrenergic sensitivity was blunted in isoproterenol-treated rats but was preserved by IGF-1 treatment. Immunoblots indicate that cardioprotective p110α signaling and activated Akt are selectively upregulated in Iso+IGF-1 treated hearts. Expression of iNOS was significantly increased in both the Iso and Iso+IGF-1 groups, however tetrahydrobiopterin (BH4) levels were decreased in the Iso group and maintained by IGF-1 treatment. Conclusion IGF-1 treatment attenuates diastolic and systolic dysfunction associated with chronic catecholamine-induced cardiomyopathy while preserving adrenergic sensitivity and promoting BH4 production. These data support the potential use of IGF-1 therapy for clinical applications for cardiomyopathies. PMID:26399932

  9. Ex vivo stretch reveals altered mechanical properties of isolated dystrophin-deficient hearts.

    Directory of Open Access Journals (Sweden)

    Matthew S Barnabei

    Full Text Available Duchenne muscular dystrophy (DMD is a progressive and fatal disease of muscle wasting caused by loss of the cytoskeletal protein dystrophin. In the heart, DMD results in progressive cardiomyopathy and dilation of the left ventricle through mechanisms that are not fully understood. Previous reports have shown that loss of dystrophin causes sarcolemmal instability and reduced mechanical compliance of isolated cardiac myocytes. To expand upon these findings, here we have subjected the left ventricles of dystrophin-deficient mdx hearts to mechanical stretch. Unexpectedly, isolated mdx hearts showed increased left ventricular (LV compliance compared to controls during stretch as LV volume was increased above normal end diastolic volume. During LV chamber distention, sarcomere lengths increased similarly in mdx and WT hearts despite greater excursions in volume of mdx hearts. This suggests that the mechanical properties of the intact heart cannot be modeled as a simple extrapolation of findings in single cardiac myocytes. To explain these findings, a model is proposed in which disruption of the dystrophin-glycoprotein complex perturbs cell-extracellular matrix contacts and promotes the apparent slippage of myocytes past each other during LV distension. In comparison, similar increases in LV compliance were obtained in isolated hearts from β-sarcoglycan-null and laminin-α(2 mutant mice, but not in dysferlin-null mice, suggesting that increased whole-organ compliance in mdx mice is a specific effect of disrupted cell-extracellular matrix contacts and not a general consequence of cardiomyopathy via membrane defect processes. Collectively, these findings suggest a novel and cell-death independent mechanism for the progressive pathological LV dilation that occurs in DMD.

  10. Magnetic resonance imaging of hypertrophic cardiomyopathy. Evaluation of diastolic function

    International Nuclear Information System (INIS)

    Schwarz, F.; Reiser, M.F.; Theisen, D.; Schwab, F.; Beckmann, B.M.; Schuessler, F.; Kaeaeb, S.; Zinsser, D.; Goelz, T.

    2013-01-01

    Hypertrophic cardiomyopathy (HCM) has a prevalence of approximately 0.2% and is clinically asymptomatic in many patients or presents with unspecific symptoms. This explains the importance of imaging for the diagnosis of HCM as well as for the assessment of the clinical course. The definitive finding in HCM is myocardial hypertrophy with thickening of the ventricular wall ≥ 15 mm. While echocardiography is an excellent screening tool magnetic resonance imaging (MRI) allows a comprehensive analysis of the heart in HCM. This includes a detailed analysis of the distribution and extent of myocardial hypertrophy, a thorough evaluation of systolic and diastolic cardiac function, the assessment of the presence and extent of dynamic outflow tract obstruction as well as the description of the systolic anterior motion (SAM) phenomenon of the mitral valve with secondary mitral insufficiency. When contrast material is administered, additional information about myocardial perfusion as well as the presence and extent of myocardial fibrosis can be obtained. This study compared systolic functional parameters as well as end systolic and end diastolic wall thickness of patients with and without diastolic dysfunction. (orig.) [de

  11. A targeted mutation within the feline leukemia virus (FeLV) envelope protein immunosuppressive domain to improve a canarypox virus-vectored FeLV vaccine.

    Science.gov (United States)

    Schlecht-Louf, Géraldine; Mangeney, Marianne; El-Garch, Hanane; Lacombe, Valérie; Poulet, Hervé; Heidmann, Thierry

    2014-01-01

    We previously delineated a highly conserved immunosuppressive (IS) domain within murine and primate retroviral envelope proteins that is critical for virus propagation in vivo. The envelope-mediated immunosuppression was assessed by the ability of the proteins, when expressed by allogeneic tumor cells normally rejected by engrafted mice, to allow these cells to escape, at least transiently, immune rejection. Using this approach, we identified key residues whose mutation (i) specifically abolishes immunosuppressive activity without affecting the "mechanical" function of the envelope protein and (ii) significantly enhances humoral and cellular immune responses elicited against the virus. The objective of this work was to study the immunosuppressive activity of the envelope protein (p15E) of feline leukemia virus (FeLV) and evaluate the effect of its abolition on the efficacy of a vaccine against FeLV. Here we demonstrate that the FeLV envelope protein is immunosuppressive in vivo and that this immunosuppressive activity can be "switched off" by targeted mutation of a specific amino acid. As a result of the introduction of the mutated envelope sequence into a previously well characterized canarypox virus-vectored vaccine (ALVAC-FeLV), the frequency of vaccine-induced FeLV-specific gamma interferon (IFN-γ)-producing cells was increased, whereas conversely, the frequency of vaccine-induced FeLV-specific interleukin-10 (IL-10)-producing cells was reduced. This shift in the IFN-γ/IL-10 response was associated with a higher efficacy of ALVAC-FeLV against FeLV infection. This study demonstrates that FeLV p15E is immunosuppressive in vivo, that the immunosuppressive domain of p15E can modulate the FeLV-specific immune response, and that the efficacy of FeLV vaccines can be enhanced by inhibiting the immunosuppressive activity of the IS domain through an appropriate mutation.

  12. Left ventricular function during acute high-altitude exposure in a large group of healthy young Chinese men.

    Directory of Open Access Journals (Sweden)

    Mingyue Rao

    Full Text Available The purpose of this study was to observe left ventricular function during acute high-altitude exposure in a large group of healthy young males.A prospective trial was conducted in Szechwan and Tibet from June to August, 2012. By Doppler echocardiography, left ventricular function was examined in 139 healthy young Chinese men at sea level; within 24 hours after arrival in Lhasa, Tibet, at 3700 m; and on day 7 following an ascent to Yangbajing at 4400 m after 7 days of acclimatization at 3700 m. The resting oxygen saturation (SaO2, heart rate (HR and blood pressure (BP were also measured at the above mentioned three time points.Within 24 hours of arrival at 3700 m, the HR, ejection fraction (EF, fractional shortening (FS, stroke volume (SV, cardiac output (CO, and left ventricular (LV Tei index were significantly increased, but the LV end-systolic dimension (ESD, end-systolic volume (ESV, SaO2, E/A ratio, and ejection time (ET were significantly decreased compared to the baseline levels in all subjects. On day 7 at 4400 m, the SV and CO were significantly decreased; the EF and FS Tei were not decreased compared with the values at 3700 m; the HR was further elevated; and the SaO2, ESV, ESD, and ET were further reduced. Additionally, the E/A ratio was significantly increased on day 7 but was still lower than it was at low altitude.Upon acute high-altitude exposure, left ventricular systolic function was elevated with increased stroke volume, but diastolic function was decreased in healthy young males. With higher altitude exposure and prolonged acclimatization, the left ventricular systolic function was preserved with reduced stroke volume and improved diastolic function.

  13. Automatic segmentation of the left ventricle in a cardiac MR short axis image using blind morphological operation

    Science.gov (United States)

    Irshad, Mehreen; Muhammad, Nazeer; Sharif, Muhammad; Yasmeen, Mussarat

    2018-04-01

    Conventionally, cardiac MR image analysis is done manually. Automatic examination for analyzing images can replace the monotonous tasks of massive amounts of data to analyze the global and regional functions of the cardiac left ventricle (LV). This task is performed using MR images to calculate the analytic cardiac parameter like end-systolic volume, end-diastolic volume, ejection fraction, and myocardial mass, respectively. These analytic parameters depend upon genuine delineation of epicardial, endocardial, papillary muscle, and trabeculations contours. In this paper, we propose an automatic segmentation method using the sum of absolute differences technique to localize the left ventricle. Blind morphological operations are proposed to segment and detect the LV contours of the epicardium and endocardium, automatically. We test the benchmark Sunny Brook dataset for evaluation of the proposed work. Contours of epicardium and endocardium are compared quantitatively to determine contour's accuracy and observe high matching values. Similarity or overlapping of an automatic examination to the given ground truth analysis by an expert are observed with high accuracy as with an index value of 91.30% . The proposed method for automatic segmentation gives better performance relative to existing techniques in terms of accuracy.

  14. Factors influencing liver and spleen volume changes after donor hepatectomy for living donor liver transplantation

    International Nuclear Information System (INIS)

    Bae, Ji Hee; Ryeom, Hunku; Song, Jung Hup

    2013-01-01

    To define the changes in liver and spleen volumes in the early postoperative period after partial liver donation for living-donor liver transplantation (LDLT) and to determine factors that influence liver and spleen volume changes. 27 donors who underwent partial hepatectomy for LDLT were included in this study. The rates of liver and spleen volume change, measured with CT volumetry, were correlated with several factors. The analyzed factors included the indocyanine green (ICG) retention rate at 15 minutes after ICG administration, preoperative platelet count, preoperative liver and splenic volumes, resected liver volume, resected-to-whole liver volume ratio (LV R /LV W ), resected liver volume to the sum of whole liver and spleen volume ratio [LV R /(LV W + SV 0 )], and pre and post hepatectomy portal venous pressures. In all hepatectomy donors, the volumes of the remnant liver and spleen were increased (increased rates, 59.5 ± 50.5%, 47.9 ± 22.6%). The increment rate of the remnant liver volume revealed a positive correlation with LV R /LV W (r = 0.759, p R /LV W influences the increment rate of the remnant liver volume.

  15. Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.; Amidan, Brett G.

    2014-09-30

    This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

  16. The study of alteration in left ventricular volume and pressure to volume ratio during exercise in patients with coronary heart disease

    International Nuclear Information System (INIS)

    Liu Zhonglin; Pei Zhuguo; Zang Bin

    1994-01-01

    The alterations induced by exercise in left ventricular end diastolic volume index (EDVI), end systolic volume index (ESVI) and systolic blood pressure to end systolic volume ratio (P/ESV) were studied in 15 normal subjects and 42 patients with coronary heart disease using a non-geometric count-based method and supine bicycle exercise test. Normal subjects had an increase in EDVI and a decrease in ESVI, but coronary heart disease patients had an increase in both EDVI and ESVI. The extent of increase induced by exercise in EDVI was greater in angina patients than that in normal and old myocardial infarction subjects. The P/ESV can be used to evaluate left ventricular systolic pressure-volume relationship. For the P/ESV exercise response, the sensitivity, specificity and accuracy for coronary heart disease were 95%, 93% and 95%, respectively

  17. Heart Failure with Preserved Ejection Fraction – Concept, Pathophysiology, Diagnosis and Challenges for Treatment

    Directory of Open Access Journals (Sweden)

    Lidija Veterovska Miljkovik

    2015-07-01

    Full Text Available Heart failure (HF with preserved left ventricular (LV ejection fraction (HFpEF occurs in 40 to 60% of the patients with HF, with a prognosis which is similar to HF with reduced ejection fraction (HFrEF. HFpEF pathophysiology is different from that of HFrEF, and has been characterized with diastolic dysfunction. Diastolic dysfunction has been defined with elevated left ventricular stiffness, prolonged iso-volumetric LV relaxation, slow LV filing and elevated LV end-diastolic pressure. Arterial hypertension occurs in majority cases with HFpEF worldwide. Patients are mostly older and obese. Diabetes mellitus and atrial fibrillation appear proportionally in a high frequency of patients with HFpEF. The HFpEF diagnosis is based on existence of symptoms and signs of heart failure, normal or approximately normal ejection and diagnosing of LV diastolic dysfunction by means of heart catheterization or Doppler echocardiography and/or elevated concentration of plasma natriuretic peptide. The present recommendations for HFpEF treatment include blood pressure control, heart chamber frequency control when atrial fibrillation exists, in some situations even coronary revascularization and an attempt for sinus rhythm reestablishment. Up to now, it is considered that no medication or a group of medications improve the survival of HFpEF patients. Due to these causes and the bad prognosis of the disorder, rigorous control is recommended of the previously mentioned precipitating factors for this disorder. This paper presents a universal review of the most important parameters which determine this disorder.

  18. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function.

    Science.gov (United States)

    Coolen, Bram F; Abdurrachim, Desiree; Motaal, Abdallah G; Nicolay, Klaas; Prompers, Jeanine J; Strijkers, Gustav J

    2013-03-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered at will to increase the frame rate because of gradient hardware, spatial resolution, and signal-to-noise limitations. To overcome these limitations associated with electrocardiography-triggered Cine MRI, in this paper, we introduce a retrospectively triggered Cine MRI protocol capable of producing high-resolution high frame rate Cine MRI of the mouse heart for addressing left ventricular diastolic function. Simulations were performed to investigate the influence of MRI sequence parameters and the k-space filling trajectory in relation to the desired number of frames per cardiac cycle. An optimized protocol was applied in vivo and compared with electrocardiography-triggered Cine for which a high-frame rate could only be achieved by several interleaved acquisitions. Retrospective high frame rate Cine MRI proved superior to the interleaved electrocardiography-triggered protocols. High spatial-resolution Cine movies with frames rates up to 80 frames per cardiac cycle were obtained in 25 min. Analysis of left ventricular filling rate curves allowed accurate determination of early and late filling rates and revealed subtle impairments in left ventricular diastolic function of diabetic mice in comparison with nondiabetic mice. Copyright © 2012 Wiley Periodicals, Inc.

  19. Factors influencing liver and spleen volume changes after donor hepatectomy for living donor liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Ji Hee; Ryeom, Hunku; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2013-11-15

    To define the changes in liver and spleen volumes in the early postoperative period after partial liver donation for living-donor liver transplantation (LDLT) and to determine factors that influence liver and spleen volume changes. 27 donors who underwent partial hepatectomy for LDLT were included in this study. The rates of liver and spleen volume change, measured with CT volumetry, were correlated with several factors. The analyzed factors included the indocyanine green (ICG) retention rate at 15 minutes after ICG administration, preoperative platelet count, preoperative liver and splenic volumes, resected liver volume, resected-to-whole liver volume ratio (LV{sub R}/LV{sub W}), resected liver volume to the sum of whole liver and spleen volume ratio [LV{sub R}/(LV{sub W} + SV{sub 0})], and pre and post hepatectomy portal venous pressures. In all hepatectomy donors, the volumes of the remnant liver and spleen were increased (increased rates, 59.5 ± 50.5%, 47.9 ± 22.6%). The increment rate of the remnant liver volume revealed a positive correlation with LV{sub R}/LV{sub W} (r = 0.759, p < 0.01). The other analyzed factors showed no correlation with changes in liver and spleen volumes. The spleen and remnant liver volumes were increased at CT volumetry performed 2 weeks after partial liver donation. Among the various analyzed factors, LV{sub R}/LV{sub W} influences the increment rate of the remnant liver volume.

  20. Termination of dobutamine infusion causes transient rebound left heart diastolic dysfunction in healthy elderly women but not in men

    DEFF Research Database (Denmark)

    Ahtarovski, Kiril A; Iversen, Kasper K; Lønborg, Jacob T

    2013-01-01

    Men and women are known to react differently to stress. Thus, stress cardiomyopathy almost solely strikes women. Stress cardiomyopathy is suggested to relate to sex differences in catecholamine reaction. Left heart function during dobutamine stress is well described, but sex-specific inotropic...... and lusitropic response to abrupt termination of dobutamine stress is not. We aimed to investigate sex differences in left ventricular (LV) and atrial (LA) function during and after dobutamine stress. We enrolled 20 healthy elderly subjects (60-70 yr, 10 females) and measured their LV and LA volumes throughout......, and conduit volumes. Sex differences were not observed at rest or during dobutamine stress. Compared with prestress values, at T15 a rebound decrease in LV peak filling rate was observed in women (-22 ± 3%, P...

  1. Cardiac magnetic resonance findings predicting mortality in patients with pulmonary arterial hypertension: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Baggen, Vivan J.M.; Leiner, Tim; Habets, Jesse; Post, Marco C.; Dijk, Arie P. van; Sieswerda, Gertjan T.; Roos-Hesselink, Jolien W.; Boersma, Eric

    2016-01-01

    To provide a comprehensive overview of all reported cardiac magnetic resonance (CMR) findings that predict clinical deterioration in pulmonary arterial hypertension (PAH). MEDLINE and EMBASE electronic databases were systematically searched for longitudinal studies published by April 2015 that reported associations between CMR findings and adverse clinical outcome in PAH. Studies were appraised using previously developed criteria for prognostic studies. Meta-analysis using random effect models was performed for CMR findings investigated by three or more studies. Eight papers (539 patients) investigating 21 different CMR findings were included. Meta-analysis showed that right ventricular (RV) ejection fraction was the strongest predictor of mortality in PAH (pooled HR 1.23 [95 % CI 1.07-1.41], p = 0.003) per 5 % decrease. In addition, RV end-diastolic volume index (pooled HR 1.06 [95 % CI 1.00-1.12], p = 0.049), RV end-systolic volume index (pooled HR 1.05 [95 % CI 1.01-1.09], p = 0.013) and left ventricular end-diastolic volume index (pooled HR 1.16 [95 % CI 1.00-1.34], p = 0.045) were of prognostic importance. RV and LV mass did not provide prognostic information (p = 0.852 and p = 0.983, respectively). This meta-analysis substantiates the clinical yield of specific CMR findings in the prognostication of PAH patients. Decreased RV ejection is the strongest and most well established predictor of mortality. (orig.)

  2. Cardiac magnetic resonance findings predicting mortality in patients with pulmonary arterial hypertension: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Baggen, Vivan J.M. [AHMaZON Centre for Adult Congenital Heart Disease, University Medical Centre Utrecht, Radboud University Medical Centre Nijmegen and St. Antonius Hospital Nieuwegein, Department of Cardiology, Utrecht (Netherlands); Erasmus Medical Centre, Department of Cardiology, Rotterdam (Netherlands); Leiner, Tim; Habets, Jesse [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands); Post, Marco C.; Dijk, Arie P. van; Sieswerda, Gertjan T. [AHMaZON Centre for Adult Congenital Heart Disease, University Medical Centre Utrecht, Radboud University Medical Centre Nijmegen and St. Antonius Hospital Nieuwegein, Department of Cardiology, Utrecht (Netherlands); Roos-Hesselink, Jolien W. [Erasmus Medical Centre, Department of Cardiology, Rotterdam (Netherlands); Boersma, Eric [Erasmus Medical Centre, Department of Cardiology, Rotterdam (Netherlands); Erasmus Medical Centre, Department of Clinical Epidemiology, Rotterdam (Netherlands)

    2016-11-15

    To provide a comprehensive overview of all reported cardiac magnetic resonance (CMR) findings that predict clinical deterioration in pulmonary arterial hypertension (PAH). MEDLINE and EMBASE electronic databases were systematically searched for longitudinal studies published by April 2015 that reported associations between CMR findings and adverse clinical outcome in PAH. Studies were appraised using previously developed criteria for prognostic studies. Meta-analysis using random effect models was performed for CMR findings investigated by three or more studies. Eight papers (539 patients) investigating 21 different CMR findings were included. Meta-analysis showed that right ventricular (RV) ejection fraction was the strongest predictor of mortality in PAH (pooled HR 1.23 [95 % CI 1.07-1.41], p = 0.003) per 5 % decrease. In addition, RV end-diastolic volume index (pooled HR 1.06 [95 % CI 1.00-1.12], p = 0.049), RV end-systolic volume index (pooled HR 1.05 [95 % CI 1.01-1.09], p = 0.013) and left ventricular end-diastolic volume index (pooled HR 1.16 [95 % CI 1.00-1.34], p = 0.045) were of prognostic importance. RV and LV mass did not provide prognostic information (p = 0.852 and p = 0.983, respectively). This meta-analysis substantiates the clinical yield of specific CMR findings in the prognostication of PAH patients. Decreased RV ejection is the strongest and most well established predictor of mortality. (orig.)

  3. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers.

    Science.gov (United States)

    Schantz, Daryl I; Dragulescu, Andreea; Memauri, Brett; Grotenhuis, Heynric B; Seed, Mike; Grosse-Wortmann, Lars

    2016-10-01

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (PHydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a "variable" that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient.

  4. Assessment of ventriculo-vascular properties in repaired coarctation using cardiac magnetic resonance-derived aortic, left atrial and left ventricular strain

    Energy Technology Data Exchange (ETDEWEB)

    Shang, Quanliang [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Central South University, Department of Radiology, Second Xiangya Hospital, Changsha, Hunan Province (China); Sarikouch, Samir; Beerbaum, Philipp [Hannover Medical School, Hannover (Germany); Patel, Shivani; Danford, David A.; Kutty, Shelby [University of Nebraska College of Medicine and Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Schuster, Andreas [Department of Cardiology and Pneumonology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Steinmetz, Michael [Department of Pediatric Cardiology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Goettingen (Germany); Ou, Phalla [University Paris Diderot, Department of Radiology, Hospital Bichat, APHP, Paris (France)

    2017-01-15

    In patients with repaired coarctation of aorta (CoA), we assessed ventriculo-vascular characteristics using CMR-derived aortic area strain (AAS), left atrial (LA) and left ventricular (LV) longitudinal and circumferential strain (LS, CS). Seventy-five subjects including 50 with repaired CoA divided into hypertensive (n = 25), normotensive (n = 25) and 25 controls were studied. AAS was measured at 3 levels: ascending aorta, proximal descending and descending aorta. LA and LV LS were measured using CMR-feature tracking. LA and LV end-diastolic volumes, ejection fraction (EF) and mass were measured. Mean patient age was 19.7 ± 6.7 and controls 23 ± 15 (years). All strains (LA, LV, ascending and descending aortic) were lower in CoA subgroups compared to controls except the AAS at diaphragm, which was not different. Comparisons between hypertensive and normotensive CoA showed no differences in LV mass, LV volumetric indices, and LA and LV strain indices; however, ascending AAS was lower in hypertensive subgroup (p = 0.02). Ascending AAS was correlated with LV mass (r = -0.4, p = 0.005), LVEF (r = -0.4, p = 0.004), systolic blood pressure (r = -0.5, p = 0.0001) and LVLS (r = 0.5, p = 0.001). Ascending AAS correlated with LV mass, EF and LVLS. In hypertensive CoA, ascending AAS was reduced compared to normotensive CoA and controls, indicating vascular remodelling differences influenced by ongoing hypertension. (orig.)

  5. Peak systolic pressure-volume relationships in man

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Katsume, Hiroshi; Ochiai, Masakazu; Ijichi, Hamao

    1985-01-01

    We determined the relationship between left ventricular (LV) peak systolic pressure (PSP) and end-systolic volume, non-invasively using cuff sphygmomanometry and radionuclide angiocardiography (RNA). Systolic blood pressure (SBP) measured in the arm was substituted for PSP. LV enddiastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were determined by a non-geometric method of gated RNA and recorded in three different hemodynamic states: at rest (basal state), during increased SBP after angiotensin administration (initial dose, 1-2 μg/min) and during decreased SBP after nitrate (sublingual nitroglycerin, 0.3-0.6 mg, or intravenous isosorbide dinitrate, 0.5-1.0 mg/min). The reproducibility of this method, tested in six subjects, proved to be good. Fifty-five subjects were divided into four groups based on EF at rest. The EDV and ESV were increased by angiotensin, and decreased by nitrate in all groups. EF was decreased by angiotensin and increased by nitrate. In contrast, the changes in PSP/ESVI due to these drugs remained in a narrow range in all groups. The regression lines of the PSP/ESVI relationship were almost linear and were steeper in the group with higher EF. Esub(max), the slope of the lines, was 5.75 +- 3.48 mmHg/ml/m 2 in group 1 (EF>50%), 3.16 +- 1.83 mmHg/ml/m 2 in group 2 (EF 49-40%), 2.27 +- 0.86 mmHg/ml/m 2 in group 3 (EF 39-30%) and 0.59 +- 0.50 mmHg/ml/m 2 in group 4 (EF<29%). The theoretical volume at zero pressure (VoI) did not meet in a definite value and was not related to EF at rest. Thus, the left ventricular peak systolic pressure-end-systolic volume relationship can be assessed non-invasively from radionuclide angiocardiography, which can be widely used for the evaluation of ventricular contractility, even in patients with asynergic ventricular contraction for whom echocardiography is unsuitable in measuring ventricular volume. (author)

  6. Studies of left ventricular volume estimation from single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hiraki, Yoshio; Shimizu, Mitsuharu; Joja, Ikuo; Aono, Kaname; Yanagi, Hidekiyo; Indo, Haruaki; Seno, Yoshimasa; Teramoto, Shigeru; Nagaya, Isao.

    1988-01-01

    We studied the comparative accuracy of 99m Tc cardiac blood pool Single Photon Emission Computed Tomography (SPECT) for the measurement of left ventricular volume in 20 patients undergoing SPECT and single plane contrast left ventriculography (LVG). Left ventricular volume was calculated based on the total number of voxels in left ventricle. End-diastolic left ventricular volume (EDV) and end-systolic left ventricular volume (ESV) calculated from SPECT were compared with those from LVG. SPECT volume values showed a high degree of correlation with those by LVG (r = 0.923 for EDV, r = 0.903 for ESV). We appreciated the usefulness and accuracy of SPECT in measuring left ventricular volume because of its three-dimensional information. (author)

  7. Exercise radionuclide ventriculographic study of mitral stenosis before and after percutaneous mirtal valvuloplasty

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Shim, Won Heum; Cho, Seung Yun; Kim, Sung Soon; Lee, Woong Ku; Kim, Myeong Jin; Choe, Kyu Ok [Yonsei University, College of Medicine, Seoul (Korea, Republic of); Park, Seung Jung [Asan Medical Center, College of Medicine, University of Ulsan, Seoul (Korea, Republic of)

    1992-11-15

    We performed radionuclide ventriculography before and within 1 week after percutaneous mirtal valvuloplasty (PMV) to evaluate left ventricular (LV) function in 20 patients (2 meals and 17 females, mean age of 38 {+-} 10 years) who were pure mitral stenosis before PMV and less than grade 1 mirtal regurgitation developed after PMV. 9 out of 20 patients had atrial fibrillation and 3 patients developed a small left-to-right shunt (Qp/Qs < 1.5) after PMV. PMV using double-balloon technique resulted in a increase in mitral valve area (0.9 {+-} 0.3 to 2.1 {+-} 0.8cm{sup 2}, {rho} < 0.001) and in rest cardiac output (4.2 {+-} 1.0 to 4.8 {+-} 1.4 L/min, {rho} < 0.005). And also a decrease in mean mitral gradient (16.2 {+-} 7.0 to 5.2 {+-} 3.0 mmHg, {rho} < 0.001) was noted. Comparisons of LV function by supine bicycle exercise radionuclide ventriculography before and after PMV showed no significant changes in rest LV ejection fraction (LVEF, 55.2 {+-} 9.7 to 56.1 {+-} 11.0%, {rho} > 0.05), maximal exercise LVEF (60.9 {+-} 10.3 to 59.3 {+-} 11.1%, {rho} > 0.05), peak ejection rate (2.02 {+-} 0.58 to 2.15 {+-} 0.60 EDV/ses, {rho} > 0.05), and peak filling rate (1.04 {+-} 0.55 to 1.52 {+-} 0.49 EDV/ses, {rho} > 0.05). However, LV end diastolic volume (LVEDV, -29.3 {+-} 19.0 to +3.3 {+-} 32.9%, {rho} < 0.001), stroke volume (SV,-22.0 {+-} 22.0 to +11.2 {+-} 40.0%, {rho} < 0.001), and cardiac output (CO, 64.6 {+-} 54.0 to 100.4 {+-} 69.7%, {rho} < 0.05) with exercise compared to resting values were significantly increased. We conclude that PMV resulted in a significant increase in LVEDV, SV, and CO with exercise, but decreased LV systolic performance and no improvement in diastolic filling.

  8. New approach for simplified and automated measurement of left ventricular ejection fraction by ECG gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu; Adachi, Haruhiko; Sugihara, Hiroki; Katsume, Hiroshi; Ijichi, Hamao; Okamoto, Kunio; Hosoba, Minoru

    1984-12-01

    Background (BKG) correction is important but debatable in the measurement of Left ventricular ejection fraction (LVEF) with ECG gated blood pool scintigraphy. We devised a new simplified BKG processing (fixed BKG method) without BKG region-of-interest (ROI) assignment, and the accuracy and reproducibility were assessed in 25 patients with various heart diseases and 5 normal subjects by comparison with LVEF obtained by contrast levolgraphy (LVG-EF). Four additional protocols for LVEF measurement with BKG-ROI assignment were also assessed for reference. LVEF calculated using the fixed BKG ratio of 0.64 (BKG count rates were 64%) of end-diastolic count rates of LV) with ''Fixed'' LV-ROI was best correlated with LVG-EF (r = 0.936, p < 0.001) and most approximated (Fixed BKG ratio method EF: 61.1 +- 20.1, LVG-EF: 61.2 +- 20.4% (mean +- SD)) among other protocols. The wide availability of the fixed value of 0.64 was tested in various diseases, body size and end-diastolic volume by LVG, and the results were to be little influenced by them. Furthermore, fixed BKG method produced lower inter-and intra- observer variability than other protocols requiring BKG-ROI assignment, probably due to its simplified processing. In conclusion, fixed BKG ratio method simplifies the measurement of LVEF, and is feasible for automated processing and single probe system.

  9. Evaluation of left ventricular diastolic function by appreciating the shape of time activity curve

    International Nuclear Information System (INIS)

    Nishimura, Tohru; Taya, Makoto; Shimoyama, Katsuya; Sasaki, Akira; Mizuno, Haruyoshi; Tahara, Yorio; Ono, Akifumi; Ishikawa, Kyozo

    1993-01-01

    To determine left ventricular diastolic function (LVDF), the shape of time activity curve and primary differential curve, as acquired by Tc-99m radionuclide angiography, were visually assessed. The study popoulation consisted of 1647 patients with heart disease, such as hypertension, ischemic heart disease, cardiomyopathy and valvular disease. Fifty-six other patients were served as controls. The LVDF was divided into 4 degrees: 0=normal, I=slight disturbance, II=moderate disturbance, and III=severe disturbance. LVDF variables, including time to peak filling (TPF), TPF/time to end-systole, peak filling rate (PFR), PFR/t, 1/3 filling fraction (1/3 FR), and 1/3 FR/t, were calculated from time activity curve. There was no definitive correlation between each variable and age or heart rate. Regarding these LVDF variables, except for 1/3 FR, there was no significant difference between the group 0 of heart disease patients and the control group. Among the groups 0-III of heart disease patients, there were significant difference in LVDF variables. Visual assessement concurred with left ventricular ejection fraction, PFR/end-diastolic curve, and filling rate/end-diastolic curve. Visual assessment using time activity curve was considered useful in the semiquantitative determination of early diastolic function. (N.K.)

  10. Assessment of left ventricular function and mass by MR imaging: a stereological study based on the systematic slice sampling procedure.

    Science.gov (United States)

    Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John

    2011-06-01

    The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  11. Assessment of Diffuse Ventricular Myocardial Fibrosis Using Native T1 in Children With Repaired Tetralogy of Fallot.

    Science.gov (United States)

    Yim, Deane; Riesenkampff, Eugenie; Caro-Dominguez, Pablo; Yoo, Shi-Joon; Seed, Mike; Grosse-Wortmann, Lars

    2017-03-01

    Myocardial fibrosis is linked with adverse clinical outcomes in adults after tetralogy of Fallot repair (rTOF). Native T1 times (T1) by cardiac magnetic resonance have been shown to be a surrogate marker of diffuse myocardial fibrosis. The objective was to quantify native T1 in children post-rTOF and to evaluate their relationship with surgical, imaging, and clinical factors. A retrospective cross-sectional study was performed. Midventricular native T1 were obtained in 100 children post-rTOF using a modified look-locker inversion recovery cardiac magnetic resonance sequence and compared with 35 pediatric controls. rTOF patients, aged 13.0±2.9 years, had higher indexed right ventricular (RV) end-diastolic (range 85-326 mL/m 2 , mean 148 mL/m 2 ) volumes, and lower RV and left ventricular (LV) ejection fractions compared with controls. RV, but not LV, T1 were higher in patients than in controls (1031±74 versus 954±32 ms, P <0.001) and female patients had higher RV T1 compared with males (1051±79 versus 1017±68 ms, P =0.02). LV T1 correlated with RV T1 ( r =0.45, P <0.001), cardiopulmonary bypass ( r =0.30, P =0.007), and aortic cross-clamp times ( r =0.32, P =0.004). RV T1 correlated inversely with RV outflow tract gradient ( r =-0.28, P =0.02). Longer aortic cross-clamp times were independently associated with LV and RV T1 on multivariable analysis. There was no association between exercise intolerance, arrhythmia, and native T1 or LV extracellular volume. Children after rTOF do not have elevated LV native T1 or LV extracellular volume, but show evidence of increased RV native T1 suggestive of diffuse RV fibrosis, for which volume loading seems to be a risk factor. Surgical bypass and cross-clamp times are associated with fibrotic remodeling over a decade later. © 2017 American Heart Association, Inc.

  12. Cardiosphere-Derived Cells Reverse Heart Failure With Preserved Ejection Fraction in Rats by Decreasing Fibrosis and Inflammation

    Directory of Open Access Journals (Sweden)

    Romain Gallet, MD

    2016-01-01

    Full Text Available The pathogenesis of heart failure with a preserved ejection fraction (HFpEF is unclear. Myocardial fibrosis, inflammation, and cardiac hypertrophy have been suggested to contribute to the pathogenesis of HFpEF. Cardiosphere-derived cells (CDCs are heart-derived cell products with antifibrotic and anti-inflammatory properties. This study tested whether rat CDCs were sufficient to decrease manifestations of HFpEF in hypertensive rats. Starting at 7 weeks of age, Dahl salt-sensitive rats were fed a high-salt diet for 6 to 7 weeks and randomized to receive intracoronary CDCs or placebo. Dahl rats fed normal chow served as controls. High-salt rats developed hypertension, left ventricular (LV hypertrophy, and diastolic dysfunction, without impairment of ejection fraction. Four weeks after treatment, diastolic dysfunction resolved in CDC-treated rats but not in placebo. The improved LV relaxation was associated with lower LV end-diastolic pressure, decreased lung congestion, and enhanced survival in CDC-treated rats. Histology and echocardiography revealed no decrease in cardiac hypertrophy after CDC treatment, consistent with the finding of sustained, equally-elevated blood pressure in CDC- and placebo-treated rats. Nevertheless, CDC treatment decreased LV fibrosis and inflammatory infiltrates. Serum inflammatory cytokines were likewise decreased after CDC treatment. Whole-transcriptome analysis revealed that CDCs reversed changes in numerous transcripts associated with HFpEF, including many involved in inflammation and/or fibrosis. These studies suggest that CDCs normalized LV relaxation and LV diastolic pressure while improving survival in a rat model of HFpEF. The benefits of CDCs occurred despite persistent hypertension and cardiac hypertrophy. By selectively reversing inflammation and fibrosis, CDCs may be beneficial in the treatment of HFpEF.

  13. Changes in left atrial deformation in hypertrophic cardiomyopathy: Evaluation by vector velocity imaging

    Directory of Open Access Journals (Sweden)

    Hala Mahfouz Badran

    2012-12-01

    Full Text Available Objectives: Hypertrophic cardiomyopathy (HCM represents a generalized myopathic process affecting both ventricular and atrial myocardium. We assessed the global and regional left atrial (LA function and its relation to left ventricular (LV mechanics and clinical status in patients with HCM using Vector Velocity Imaging (VVI. Methods: VVI of the LA and LV was acquired from apical four- and two-chamber views of 108 HCM patients (age 40±19years, 56.5% men and 33 healthy subjects, all had normal LV systolic function. The LA subendocardium was traced to obtain atrial volumes, ejection fraction, velocities, and strain (ɛ/strain rate (SR measurements. Results: Left atrial reservoir (ɛsys,SRsys and conduit (early diastolic SRe function were significantly reduced in HCM compared to controls (P-1.8s-1 was 81% sensitive and 30% specific, SRa>-1.5s-1 was 73% sensitive and 40% specific. By multivariate analysis global LVɛsys and LV septal thickness are independent predictors for LAɛsys, while end systolic diameter is the only independent predictor for SRsys, P<.001. Conclusion: Left atrial reservoir and conduit function as measured by VVI were significantly impaired while contractile function was preserved among HCM patients. Left atrial deformation was greatly influenced by LV mechanics and correlated to severity of phenotype.

  14. "Pulmonary valve replacement diminishes the presence of restrictive physiology and reduces atrial volumes": a prospective study in Tetralogy of Fallot patients.

    Science.gov (United States)

    Pijuan-Domenech, Antonia; Pineda, Victor; Castro, Miguel Angel; Sureda-Barbosa, Carlos; Ribera, Aida; Cruz, Luz M; Ferreira-Gonzalez, Ignacio; Dos-Subirà, Laura; Subirana-Domènech, Teresa; Garcia-Dorado, David; Casaldàliga-Ferrer, Jaume

    2014-11-15

    Pulmonary valve replacement (PVR) reduces right ventricular (RV) volumes in the setting of long-term pulmonary regurgitation after Tetralogy of Fallot (ToF) repair; however, little is known of its effect on RV diastolic function. Right atrial volumes may reflect the burden of RV diastolic dysfunction. The objective of this paper is to evaluate the clinical, echocardiographic, biochemical and cardiac magnetic resonance (CMR) variables, focusing particularly on right atrial response and right ventricular diastolic function prior to and after elective PVR in adult patients with ToF. This prospective study was conducted from January 2009 to April 2013 in consecutive patients > 18 years of age who had undergone ToF repair in childhood and were accepted for elective PVR. Twenty patients (mean age: 35 years; 70% men) agreed to enter the study. PVR was performed with a bioporcine prosthesis. Concomitant RV reduction was performed in all cases when technically possible. Pulmonary end-diastolic forward flow (EDFF) decreased significantly from 5.4 ml/m(2) to 0.3 ml/m(2) (p volumes by 25% (p = 0.0024): mean indexed diastolic/systolic atrial volumes prior to surgery were 43 ml/m(2) (SD+/-4.6)/63 ml/m(2) (SD+/-5.5), and dropped to 33 ml/m(2) (SD+/-3)/46 ml/m(2) (SD+/-2.55) post-surgery. All patients presented right ventricular diastolic and systolic volume reductions, with a mean volume reduction of 35% (p volumes in keeping with the known reduction in RV volumes, after PVR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Utility of pulmonary venous flow diastolic deceleration time in an adult patient undergoing surgical closure of atrial septal defect and coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Dharmesh R Agrawal

    2013-01-01

    Full Text Available Acute left ventricular (LV failure has been reported after surgical closure of atrial septal defect (ASD in adult patients. We report acute LV failure in a 56 year old gentleman following coronary artery bypass grafting (CABG and surgical closure of ASD. Transesophageal echocardiography examination of the patient following closure of ASD and CABG showed a residual ASD and a shunt (Qp :Qs = 1.5. The residual ASD was closed after re-institution of cardiopulmonary bypass (CPB under cardioplegic cardiac arrest. However, the patient did not tolerate closure of the residual ASD. The CPB was re-established and under cardioplegic cardiac arrest residual ASD was reopened to create a fenestration. This time patient was weaned easily from CPB. Postoperatively, 16 hours after extubation, patient became hemodynamically unstable, the patient was electively put on ventilator and intra-aortic balloon pump. Later the patient was weaned off successfully from ventilator. Retrospective analysis of pulmonary venous flow diastolic deceleration time (PVDT D recorded during prebypass period measured 102 msec suggestive of high left atrial pressure which indicate possibility of LV failure after ASD closure.

  16. Prognostic value of systolic mitral annular velocity measured with Doppler tissue imaging in patients with chronic heart failure caused by left ventricular systolic dysfunction

    Science.gov (United States)

    Nikitin, N P; Loh, P H; de Silva, R; Ghosh, J; Khaleva, O Y; Goode, K; Rigby, A S; Alamgir, F; Clark, A L; Cleland, J G F

    2006-01-01

    Objective To assess the prognostic value of various conventional and novel echocardiographic indices in patients with chronic heart failure (CHF) caused by left ventricular (LV) systolic dysfunction. Methods 185 patients with a mean (SD) age of 67 (11) years with CHF and LV ejection fraction < 45% despite optimal pharmacological treatment were prospectively enrolled. The patients underwent two dimensional echocardiography with tissue harmonic imaging to assess global LV systolic function and obtain volumetric data. Transmitral flow was assessed with conventional pulse wave Doppler. Systolic (Sm), early, and late diastolic mitral annular velocities were measured with the use of colour coded Doppler tissue imaging. Results During a median follow up of 32 months (range 24–38 months in survivors), 34 patients died and one underwent heart transplantation. Sm velocity (hazard ratio (HR) 0.648, 95% confidence interval (CI) 0.463 to 0.907, p  =  0.011), diastolic arterial pressure (HR 0.965, 95% CI 0.938 to 0.993, p  =  0.015), serum creatinine (HR 1.006, 95% CI 1.001 to 1.011, p  =  0.023), LV ejection fraction (HR 0.945, 95% CI 0.899 to 0.992, p  =  0.024), age (HR 1.035, 95% CI 1.000 to 1.071, p  =  0.052), LV end systolic volume index (HR 1.009, 95% CI 0.999 to 1.019, p  =  0.067), and restrictive pattern of transmitral flow (HR 0.543, 95% CI 0.278 to 1.061, p  =  0.074) predicted the outcome of death or transplantation on univariate analysis. On multivariate analysis, only Sm velocity (HR 0.648, 95% CI 0.460 to 0.912, p  =  0.013) and diastolic arterial pressure (HR 0.966, 95% CI 0.938 to 0.994, p  =  0.016) emerged as independent predictors of outcome. Conclusions In patients with CHF and LV systolic dysfunction despite optimal pharmacological treatment, the strongest independent echocardiographic predictor of prognosis was Sm velocity measured with quantitative colour coded Doppler tissue

  17. The accuracy of ventricular volume measurement and the optimal slice thickness by using multislice helical computed tomography

    International Nuclear Information System (INIS)

    Cui Wei; Guo Yuyin

    2005-01-01

    Objective: To determine the optimal slice thickness for ventricular volume measurement by tomographic multislice Simpson's method and to evaluate the accuracy of ventricular volume measured by multislice helical computed tomography (MSCT) in human ventricular casts. Methods: Fourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned with MSCT scanner by using a scanning protocol similar to clinical practice. A series of LV and RV short-axis images were reconstructed with slice thickness of 2 mm, 3.5 mm, 5 mm, 7 mm, and 10 mm, respectively. Multislice Simpson's method was used to calculate LV and RV volumes and true cast volume was determined by water displacement. Results: The true LV and RV volumes were (55.57 ± 28.91) ml, and (64.23 ± 24.51) ml, respectively. The calculated volumes from different slice thickness ranged from (58.78 ± 28.93) ml to (68.15 ± 32.57) ml for LV casts, and (74.45 ± 27.81) ml to (88.14 ± 32.91) ml for RV casts, respectively. Both the calculated LV and RV volumes correlated closely with the corresponding true volumes (all r > 0.95, P<0.001), but overestimated the corresponding true volume by (3.21 ± 5.95) to (12.58 ± 8.56) ml for LV and (10.22 ± 8.45) to (23.91 ± 12.24) ml for RV (all P<0.01). There was a close correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P<0.001). However, when slice thickness was reduced to 5.0 mm, the overestimation became nonsignificant for slice thickness through 2.0 mm to 5.0 mm, and also for both LV and RV volume measurements. Conclusion: Both LV and RV volumes can be accurately calculated with MSCT. A 5 mm slice thickness is enough and most efficient for accurate measurement of LV and RV volume. (authors)

  18. Diastolic coronary artery pressure-flow velocity relationships in conscious man.

    Science.gov (United States)

    Dole, W P; Richards, K L; Hartley, C J; Alexander, G M; Campbell, A B; Bishop, V S

    1984-09-01

    We characterised the diastolic pressure-flow velocity relationship in the normal left coronary artery of conscious man before and after vasodilatation with angiographic contrast medium. Phasic coronary artery pressure and flow velocity were measured in ten patients during individual diastoles (0.5 to 1.0 s) using a 20 MHz catheter-tipped, pulsed Doppler transducer. All pressure-flow velocity curves were linear over the diastolic pressure range of 110 +/- 15 (SD) mmHg to 71 +/- 7 mmHg (r = 0.97 +/- 0.01). In the basal state, values for slope and extrapolated zero flow pressure intercept averaged 0.35 +/- 0.12 cm X s-1 X mmHg-1 and 51.7 +/- 8.6 mmHg, respectively. Vasodilatation resulted in a 2.5 +/- 0.5 fold increase in mean flow velocity. The diastolic pressure-flow velocity relationship obtained during peak vasodilatation compared to that during basal conditions was characterised by a steeper slope (0.80 +/- 0.48 cm X s-1 X mmHg-1, p less than 0.001) and lower extrapolated zero flow pressure intercept (37.9 +/- 9.8 mmHg, p less than 0.05). Mean right atrial pressure for the group averaged 4.4 +/- 1.7 mmHg, while left ventricular end-diastolic pressure averaged 8.7 +/- 2.8 mmHg. These observations in man are similar to data reported in the canine coronary circulation which are consistent with a vascular waterfall model of diastolic flow regulation. In this model, coronary blood flow may be regulated by changes in diastolic zero flow pressure as well as in coronary resistance.

  19. Precision of gated equilibrium radioventriculography in measuring left ventricular stroke volume

    International Nuclear Information System (INIS)

    Bourguignon, M.H.; Wise, R.A.; Ehrlich, W.E.; Douglas, K.H.; Camargo, E.E.; Harrison, K.E.; Wagner, H.N. Jr.

    1983-01-01

    We have demonstrated that relative changes of small amplitude in ventricular stroke volume can be measured accurately in dogs when a fully automated technique for delineation of end diastolic and end systolic region of interest (ROI) is used. Consequently, we expect such a technique to be very sensitive in measuring relative changes of any ventricular quantitative parameter from gated equilibrium radio ventriculography in humans

  20. Myocardial perfusion SPECT for assessment of left ventricular function and volume- comparison with echocardiography

    International Nuclear Information System (INIS)

    Cheng Xu; Huang Gang

    2004-01-01

    Objective: The purpose of this study was to evaluate left ventricular volume and function by gated SPECT and comparison of the results with echocardiography. Methods: 65 Consecutive patients (49 male, 16 female; mean age 61+11 years) who underwent both gated 99m Tc-MIBI myocardial perfusion SPECT and echocardiography within a 15 days period were included in the study. Exclusion criteria were any change in clinical status between acquisition of the gated SPECT and echocardiography studies, acute myocardial infarction occurring less than 7 days before study, and surgical procedures occurring within 30 days of the study. The clinical diagnosis of each patient was not considered, as this was not relevant to the purpose of the study. The diagnoses were as follows: coronary artery disease (n=46), hypertensive heart disease (n=8), old myocardial infarction (n=5), myocarditis (n=2), and routine medical examination(n=4). A dose of 740 MBq of 99 Tc m -sestamibi was administered in resting condition. Gated SPECT images were obtained with ADAC Vertex MCD-AC SPECT system. The raw projection images were reconstructed with filtered back-projection (ramp filter), without attenuation correction. The data, including left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV) were obtained using AUTOQUANT software (ADAC corporation). The echocardiography study used its standard techniques. Two nuclear medicine physicians processed the raw images respectively to evaluate internal reproducibility of gated SPECT. In order to compare the results of gated SPECT with echocardiography on different left ventricular volumes, all patients were divided into two groups (EDV 90 ml, n=34) based by EDV measurements in echocardiography. Results: The correlation coefficient of LVEF, EDV, ESV between SPECT and echocardiography were 0.77, 0.86 and 0.90 respectively. P 0.07). The reproducibility of gated SPECT was excellent. There were no significant differences in

  1. Comparative Efficacy of Feline Leukemia Virus (FeLV) Inactivated Whole-Virus Vaccine and Canarypox Virus-Vectored Vaccine during Virulent FeLV Challenge and Immunosuppression.

    Science.gov (United States)

    Patel, M; Carritt, K; Lane, J; Jayappa, H; Stahl, M; Bourgeois, M

    2015-07-01

    Four vaccines for feline leukemia virus (FeLV) are available in the United States. This study's purpose was to compare the efficacy of Nobivac feline 2-FeLV (an inactivated, adjuvanted whole-virus vaccine) and PureVax recombinant FeLV (a live, canarypox virus-vectored vaccine) following FeLV challenge. Cats were vaccinated at 9 and 12 weeks with Nobivac feline 2-FeLV (group A, n = 11) or PureVax recombinant FeLV (group B, n = 10). Group C (n = 11) comprised unvaccinated controls. At 3 months postvaccination, cats were immunosuppressed and challenged with FeLV-A/61E. The outcomes measured were persistent antigenemia at 12 weeks postchallenge (PC) and proviral DNA and viral RNA at 3 to 9 weeks PC. Persistent antigenemia was observed in 0 of 11 cats in group A, 5 of 10 cats in group B, and 10 of 11 cats in group C. Group A was significantly protected compared to those in groups B (P 0.063). The preventable fraction was 100% for group A and 45% for group B. At 9 weeks PC, proviral DNA and viral RNA were detected 1 of 11 cats in group A, 6 of 10 cats in group B, and 9 of 11 cats in group C. Nucleic acid loads were significantly lower in group A than in group C (P feline 2-FeLV-vaccinated cats were fully protected against persistent antigenemia and had significantly smaller amounts of proviral DNA and plasma viral RNA loads than PureVax recombinant FeLV-vaccinated cats and unvaccinated controls. Copyright © 2015, Patel et al.

  2. MRI-based volumetric assessment of cardiac anatomy and dose reduction via active breathing control during irradiation for left-sided breast cancer

    International Nuclear Information System (INIS)

    Krauss, Daniel J.; Kestin, Larry L.; Raff, Gilbert; Yan Di; Wong, John; Gentry, Ralph; Letts, Nicola; Vargas, Carlos E.; Martinez, Alvaro A.; Vicini, Frank A.

    2005-01-01

    Purpose: Heart dose-volume analysis using computed tomography (CT) is limited because of motion artifact and poor delineation between myocardium and ventricular space. We used dedicated cardiac magnetic resonance imaging (MRI) to quantify exclusion of left ventricular (LV) myocardium via active breathing control (ABC) during left breast irradiation and to determine the correlation between irradiated whole heart and LV volumes. Methods and materials: Fifteen patients who completed adjuvant irradiation for early-stage left breast cancer participated. Treatment consisted of 45 Gy to the entire breast using ABC followed by a 16-Gy electron boost to the lumpectomy cavity. Patients underwent planning CT scans in free breathing (FB) and moderate deep inspiration breath hold (mDIBH). Electrocardiogram-gated cardiac MRI was performed in the treatment position using α-cradle immobilization. MRI scans were acquired in late diastole (LD), mid-diastole (MD), and systole (S) for both FB and mDIBH. After image fusion with the patients' radiation therapy planning CT scan, MRI LV volumes were defined for the three examined phases of the cardiac cycle, and comparative dose-volume analysis was performed. Results: Cardiac volume definition was found to differ significantly because of combinations of respiratory and intrinsic heart motion. The fraction of LV myocardium receiving 50% (22.5 Gy) of the prescribed whole breast dose (V 22.5 ) was reduced by 85.3%, 91.8%, and 94.6% via ABC for LD, MD, and S, respectively. Linear regression revealed strong correlation between MRI-defined whole heart and LV V 22.5 reduction via ABC, suggesting that LV myocardium accounts for up to approximately 50% of the excluded heart volume through this technique. Significant but weaker correlations were noted between CT-defined whole heart and LV V 22.5 reductions with marked variability in the measurements of patients with larger amounts of heart in the treatment field. Conclusions: Cardiac MRI

  3. Spatial correlation of action potential duration and diastolic dysfunction in transgenic and drug-induced LQT2 rabbits.

    Science.gov (United States)

    Odening, Katja E; Jung, Bernd A; Lang, Corinna N; Cabrera Lozoya, Rocio; Ziupa, David; Menza, Marius; Relan, Jatin; Franke, Gerlind; Perez Feliz, Stefanie; Koren, Gideon; Zehender, Manfred; Bode, Christoph; Brunner, Michael; Sermesant, Maxime; Föll, Daniela

    2013-10-01

    Enhanced dispersion of action potential duration (APD) is a major contributor to long QT syndrome (LQTS)-related arrhythmias. To investigate spatial correlations of regional heterogeneities in cardiac repolarization and mechanical function in LQTS. Female transgenic LQTS type 2 (LQT2; n = 11) and wild-type littermate control (LMC) rabbits (n = 9 without E4031 and n = 10 with E4031) were subjected to phase contrast magnetic resonance imaging to assess regional myocardial velocities. In the same rabbits' hearts, monophasic APDs were assessed in corresponding segments. In LQT2 and E4031-treated rabbits, APD was longer in all left ventricular segments (P < .01) and APD dispersion was greater than that in LMC rabbits (P < .01). In diastole, peak radial velocities (Vr) were reduced in LQT2 and E4031-treated compared to LMC rabbits in LV base and mid (LQT2: -3.36 ± 0.4 cm/s, P < .01; E4031-treated: -3.24 ± 0.6 cm/s, P < .0001; LMC: -4.42 ± 0.5 cm/s), indicating an impaired diastolic function. Regionally heterogeneous diastolic Vr correlated with APD (LQT2: correlation coefficient [CC] 0.38, P = .01; E4031-treated: CC 0.42, P < .05). Time-to-diastolic peak Vr were prolonged in LQT2 rabbits (LQT2: 196.8 ± 2.9 ms, P < .001; E4031-treated: 199.5 ± 2.2 ms, P < .0001, LMC 183.1 ± 1.5), indicating a prolonged contraction duration. Moreover, in transgenic LQT2 rabbits, diastolic time-to-diastolic peak Vr correlated with APD (CC 0.47, P = .001). In systole, peak Vr were reduced in LQT2 and E4031-treated rabbits (P < .01) but longitudinal velocities or ejection fraction did not differ. Finally, random forest machine learning algorithms enabled a differentiation between LQT2, E4031-treated, and LMC rabbits solely based on "mechanical" magnetic resonance imaging data. The prolongation of APD led to impaired diastolic and systolic function in transgenic and drug-induced LQT2 rabbits. APD correlated with regional diastolic dysfunction, indicating that LQTS is not purely an

  4. Accelerated cardiovascular magnetic resonance of the mouse heart using self-gated parallel imaging strategies does not compromise accuracy of structural and functional measures

    Directory of Open Access Journals (Sweden)

    Dörries Carola

    2010-07-01

    Full Text Available Abstract Background Self-gated dynamic cardiovascular magnetic resonance (CMR enables non-invasive visualization of the heart and accurate assessment of cardiac function in mouse models of human disease. However, self-gated CMR requires the acquisition of large datasets to ensure accurate and artifact-free reconstruction of cardiac cines and is therefore hampered by long acquisition times putting high demands on the physiological stability of the animal. For this reason, we evaluated the feasibility of accelerating the data collection using the parallel imaging technique SENSE with respect to both anatomical definition and cardiac function quantification. Results Findings obtained from accelerated data sets were compared to fully sampled reference data. Our results revealed only minor differences in image quality of short- and long-axis cardiac cines: small anatomical structures (papillary muscles and the aortic valve and left-ventricular (LV remodeling after myocardial infarction (MI were accurately detected even for 3-fold accelerated data acquisition using a four-element phased array coil. Quantitative analysis of LV cardiac function (end-diastolic volume (EDV, end-systolic volume (ESV, stroke volume (SV, ejection fraction (EF and LV mass in healthy and infarcted animals revealed no substantial deviations from reference (fully sampled data for all investigated acceleration factors with deviations ranging from 2% to 6% in healthy animals and from 2% to 8% in infarcted mice for the highest acceleration factor of 3.0. CNR calculations performed between LV myocardial wall and LV cavity revealed a maximum CNR decrease of 50% for the 3-fold accelerated data acquisition when compared to the fully-sampled acquisition. Conclusions We have demonstrated the feasibility of accelerated self-gated retrospective CMR in mice using the parallel imaging technique SENSE. The proposed method led to considerably reduced acquisition times, while preserving high

  5. The influence of adrenergic stimulation on sex differences in left ventricular twist mechanics.

    Science.gov (United States)

    Williams, Alexandra M; Shave, Rob E; Cheyne, William S; Eves, Neil D

    2017-06-15

    Sex differences in left ventricular (LV) mechanics occur during acute physiological challenges; however, it is unknown whether sex differences in LV mechanics are fundamentally regulated by differences in adrenergic control. Using two-dimensional echocardiography and speckle tracking analysis, this study compared LV mechanics in males and females matched for LV length during post-exercise ischaemia (PEI) and β 1 -adrenergic receptor blockade. Our data demonstrate that while basal rotation was increased in males, LV twist was not significantly different between the sexes during PEI. In contrast, during β 1 -adrenergic receptor blockade, LV apical rotation, twist and untwisting velocity were reduced in males compared to females. Significant relationships were observed between LV twist and LV internal diameter and sphericity index in females, but not males. These findings suggest that LV twist mechanics may be more sensitive to alterations in adrenergic stimulation in males, but more highly influenced by ventricular structure and geometry in females. Sex differences in left ventricular (LV) mechanics exist at rest and during acute physiological stress. Differences in cardiac autonomic and adrenergic control may contribute to sex differences in LV mechanics and LV haemodynamics. Accordingly, this study aimed to investigate sex differences in LV mechanics with altered adrenergic stimulation achieved through post-handgrip-exercise ischaemia (PEI) and β 1 -adrenergic receptor (AR) blockade. Twenty males (23 ± 5 years) and 20 females (22 ± 3 years) were specifically matched for LV length (males: 8.5 ± 0.5 cm, females: 8.2 ± 0.6 cm, P = 0.163), and two-dimensional speckle-tracking echocardiography was used to assess LV structure and function at baseline, during PEI and following administration of 5 mg bisoprolol (β 1 -AR antagonist). During PEI, LV end-diastolic volume and stroke volume were increased in both groups (P adrenergic stimulation

  6. L.V. switchgear - design and development

    International Nuclear Information System (INIS)

    Armes, D.S.; Brown, R.D.

    1992-01-01

    This work describes the methods employed in the design and development of L.V. switchgear to meet the prospective conditions and operational requirements imposed on equipment at sites of PWR power stations. The work concentrates on the aspects of design, manufacture, qualification work and quality assurance particular to the range of L.V. switchgear distribution boards manufactured by Laurence, Scott and Electromotors Ltd. for Sizewell B Power Station and contrasts this equipment with other equipment for conventional (i.e. non-nuclear) power station purposes. (Author)

  7. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis

    International Nuclear Information System (INIS)

    Kaniewska, Malwina; Schuetz, Georg M.; Willun, Steffen; Dewey, Marc; Schlattmann, Peter

    2017-01-01

    To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I"2 statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. (orig.)

  8. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kaniewska, Malwina; Schuetz, Georg M.; Willun, Steffen; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Schlattmann, Peter [Jena University Hospital, Department of Medical Statistics, Informatics and Documentation, Jena (Germany)

    2017-04-15

    To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I{sup 2} statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. (orig.)

  9. Pulmonary thallium uptake: Correlation with systolic and diastolic left ventricular function at rest and during exercise

    International Nuclear Information System (INIS)

    Mannting, F.

    1990-01-01

    Quantified pulmonary 201-thallium uptake, assessed as pulmonary/myocardial ratios (PM) and body surface area-corrected absolute pulmonary uptake (Pc), was determined from single photon emission computed tomography studies in 22 normal subjects and 46 consecutive patients with coronary artery disease (CAD). By means of equilibrium radionuclide angiography (ERNA), ejection fraction (EF), peak ejection rate (PER) in end-diastolic volume (EDV/sec) and peak filling rate (PFR) in EDV/sec and stroke volume (SV/sec) units, PFR/PER ratio, and time to peak filling rate (TPFR) in milliseconds were computed at rest and during exercise (n = 35). Left ventricular response to exercise was assessed as delta EF, relative delta EF, delta EDV, and delta ESV. In normal subjects the PM ratios showed significant inverse correlation with PER at rest and with EF, PER, and PFRedv during exercise. For the left ventricular response to exercise, delta ESV showed significant correlation with the PM ratios. The body surface area-corrected pulmonary uptake values showed no correlation with any of the variables. In patients with CAD the PM ratios and Pc uptake showed significant inverse correlation with EF, PER, PFRedv and to exercise EF, exercise PER, and exercise PFRedv. For the left ventricular response to exercise, delta EF showed significant inverse correlation with the PM ratios but not with the Pc uptake. Neither in normal subjects nor in patients with CAD did any of the independent diastolic variables show significant correlation with the PM ratios or Pc values. Thus pulmonary thallium uptake is correlated with systolic left ventricular function at rest and during exercise in normal subjects and in patients with CAD but not with diastolic function. In normal subjects delta ESV and in patients with CAD, delta EF showed correlation with pulmonary thallium uptake

  10. Diastolic pressure underestimates age-related hemodynamic impairment.

    Science.gov (United States)

    Galarza, C R; Alfie, J; Waisman, G D; Mayorga, L M; Cámera, L A; del Río, M; Vasvari, F; Limansky, R; Farías, J; Tessler, J; Cámera, M I

    1997-10-01

    It has been hypothesized that as large arteries become more rigid with age, the pattern of hypertension changes from diastolic to systolic. Thus, diastolic blood pressure (DBP) may lose its ability to reflect the increase in vascular resistance with age. To assess this, we studied the age-related changes in blood pressure pattern and its steady-state and pulsatile determinants. We performed an epidemiological analysis based on a national survey of 10,462 subjects from Argentina. A hemodynamic analysis (impedance cardiography) was then carried out in 636 consecutive hypertensive patients (age, 25 to 74 years). Whereas the rate of increment in the prevalence of mild to moderate hypertension (MMH) reached a plateau after the sixth decade, isolated and borderline systolic forms of hypertension began a steep and sustained rise. Among patients with MMH, DBP remained stable from the third to the seventh decade, whereas SBP maintained a sustained increase. Despite similar DBP, the systemic vascular resistance index increased 47% (P<.01) and the cardiac index decreased 27% (P<.01), whereas the ratio of stroke volume to pulse pressure, an index of arterial compliance, decreased 45% (P<.01). However, there were no significant differences between older patients with MMH and those with isolated systolic hypertension in the level of SBP, vascular resistance, stroke volume, and cardiac index. Compared with age-matched normotensive control subjects, the ratio of stroke volume to pulse pressure was much more reduced in isolated systolic hypertension (48%) than in MMH (30%). In summary, the present study, carried out in a large sample of hypertensive subjects with a wide age range, showed a simultaneous impairment in vascular resistance and arterial compliance associated with aging in different patterns of hypertension. The magnitude of these changes, with opposite effects on DBP but additive effects on SBP, suggests that a hemodynamic mechanism could determine the transition in the

  11. A new dynamic myocardial phantom for evaluation of SPECT and PET quantitation in systolic and diastolic conditions

    International Nuclear Information System (INIS)

    Dreuille, O. de; Bendriem, B.; Riddell, C.

    1996-01-01

    We present a new dynamic myocardial phantom designed to evaluate SPECT and PET imaging in systolic and diastolic conditions. The phantom includes a thoracic attenuating media and the myocardial wall thickness varying during the scan can be performed. In this study the phantom was used with three different wall thickness characteristic of a systolic, end-diastolic and pathologic end-diastolic condition. The myocardium was filled with 99m Tc, 18 F and Gd and imaged by SPECT, PET and MRI. SPECT attenuation correction was performed using a modified PET transmission. A bull's eyes image was obtained for all data and wall ROI were then drawn for analysis. Using MRI as a reference, error from PET, SPECT and attenuation corrected SPECT were calculated. Systolic PET performances agree with MRI. Quantitation loss due to wall thickness reduction compared to the systole. Attenuation correction in SPECT leads to significant decrease of the error both in systole (from 29% to 14%) and diastole (35% to 22%). This is particularly sensitive for septum and inferior walls. SPECT residual errors (14% in systole and 22% in pathologic end-diastole) are likely caused by scatter, noise and depth dependent resolution effect. The results obtained with this dynamical phantom demonstrate the quantitation improvement achieved in SPECT with attenuation correction and also reinforce the need for variable resolution correction in addition to attenuation correction

  12. Dissociation between cardiomyocyte function and remodeling with beta-adrenergic receptor blockade in isolated canine mitral regurgitation.

    Science.gov (United States)

    Pat, Betty; Killingsworth, Cheryl; Denney, Thomas; Zheng, Junying; Powell, Pamela; Tillson, Michael; Dillon, A Ray; Dell'Italia, Louis J

    2008-12-01

    The low-pressure volume overload of isolated mitral regurgitation (MR) is associated with increased adrenergic drive, left ventricular (LV) dilatation, and loss of interstitial collagen. We tested the hypothesis that beta1-adrenergic receptor blockade (beta1-RB) would attenuate LV remodeling after 4 mo of MR in the dog. beta1-RB did not attenuate collagen loss or the increase in LV mass in MR dogs. Using MRI and three-dimensional (3-D) analysis, there was a 70% increase in the LV end-diastolic (LVED) volume-to-LV mass ratio, a 23% decrease in LVED midwall circumferential curvature, and a >50% increase in LVED 3-D radius/wall thickness in MR dogs that was not attenuated by beta1-RB. However, beta1-RB caused a significant increase in LVED length from the base to apex compared with untreated MR dogs. This was associated with an increase in isolated cardiomyocyte length (171+/-5 microm, P<0.05) compared with normal (156+/-3 microm) and MR (165+/-4 microm) dogs. Isolated cardiomyocyte fractional shortening was significantly depressed in MR dogs compared with normal dogs (3.73+/-0.31 vs. 5.02+/-0.26%, P<0.05) and normalized with beta1-RB (4.73+/-0.48%). In addition, stimulation with the beta-adrenergic receptor agonist isoproterenol (25 nM) increased cardiomyocyte fractional shortening by 215% (P<0.05) in beta1-RB dogs compared with normal (56%) and MR (50%) dogs. In summary, beta1-RB improved LV cardiomyocyte function and beta-adrenergic receptor responsiveness despite further cell elongation. The failure to attenuate LV remodeling associated with MR could be due to a failure to improve ultrastructural changes in extracellular matrix organization.

  13. Association of ACE gene D polymorphism with left ventricular hypertrophy in patients with diastolic heart failure: a case-control study.

    Science.gov (United States)

    Bahramali, Ehsan; Rajabi, Mona; Jamshidi, Javad; Mousavi, Seyyed Mohammad; Zarghami, Mehrdad; Manafi, Alireza; Firouzabadi, Negar

    2016-02-09

    To explore the association between ACE gene insertion/deletion (I/D) polymorphism with left ventricular hypertrophy (LVH) in patients with hypertension who have developed heart failure with preserved ejection fraction (HFpEF). Being a major contributor to the development of diastolic heart dysfunction, the renin angiotensin aldosterone system and its genetic variations are thought to induce LVH in hypertensive hearts apart from haemodynamic factors. Case control study. An Iranian referral university hospital. 176 patients with hypertension and a diagnosis of HFpEF on presence of symptoms of heart failure plus Doppler echocardiographic documentation of left ventricular (LV) diastolic dysfunction and/or elevated NT-proBNP levels. Those with significant coronary, valvular, pericardial and structural heart diseases were excluded as well as patients with atrial fibrillation, renal failure and pulmonary causes of dyspnoea. They were divided into two cohorts of 88 cases with and 88 controls without LVH, after determination of LV mass index, using two-dimensional and M-mode echocardiography. The I/D polymorphism of the ACE gene was determined using the PCR method. The D allele was significantly more prevalent among cases with compared with controls without LVH (p=0.0007). Genotype distributions also differed significantly under additive (p=0.005, OR=0.53, 95% CI 0.34 to 0.84) and recessive (p=0.001, OR=0.29, 95% CI 0.13 to 0.66) models. In patients with hypertension who develop HFpEF, the D allele of the ACE gene is probably associated with the development of LVH. With the detrimental effects of LVH on the heart's diastolic properties, this can signify the role of genetic contributors to the development of HFpEF in patients with hypertension and may serve as a future risk predictor for the disease. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Left ventricular function in response to dipyridamole stress: head-to-head comparison between {sup 82}Rubidium PET and {sup 99m}Tc-sestamibi SPECT ECG-gated myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giorgi, Maria Clementina; Meneghetti, Jose Claudio; Soares, Jose; Izaki, Marisa; Falcao, Andrea; Imada, Rodrigo; Chalela, William; Oliveira, Marco Antonio de; Nomura, Cesar [Department of Radiology and Nuclear Medicine and Molecular Imaging Service - Heart Institute of the University of Sao Paulo Medical School, Sao Paulo (Brazil); Verberne, Hein J. [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, P.O. Box 22700, Amsterdam (Netherlands)

    2017-05-15

    Myocardial perfusion imaging (MPI) with {sup 99m}Tc-sestamibi (sestamibi) SPECT and rubidium-82 ({sup 82}Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and {sup 82}Rb MPI after a single dipyridamole stress dose. Sestamibi and {sup 82}Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the {sup 82}Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R{sup 2} = 0.261, p = 0.005; R{sup 2} = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and {sup 82}Rb showed no significant trend post-stress (R{sup 2} = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R{sup 2} = 0.032, p = 0.009). Differences in left ventricular volumes between sestamibi and {sup 82}Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and {sup 82}Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and {sup 82}Rb MPI. (orig.)

  15. Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass

    International Nuclear Information System (INIS)

    Nadkarni, S.K.; Drangova, M.; Boughner, D.R.; Fenster, A.; Department of Medical Biophysics, Medical Sciences Building, University of Western Ontario, London, Ontario N6A 5C1

    2000-01-01

    Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEM inter = 13.5%, %SEM intra = 11.4%, and for 2D echocardiography was %SEM inter = 21.5%, %SEM intra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography. (author)

  16. Acute Cardiac Impairment Associated With Concurrent Chemoradiotherapy for Esophageal Cancer: Magnetic Resonance Evaluation

    International Nuclear Information System (INIS)

    Hatakenaka, Masamitsu; Yonezawa, Masato; Nonoshita, Takeshi; Nakamura, Katsumasa; Yabuuchi, Hidetake; Shioyama, Yoshiyuki; Nagao, Michinobu; Matsuo, Yoshio; Kamitani, Takeshi; Higo, Taiki; Nishikawa, Kei; Setoguchi, Taro; Honda, Hiroshi

    2012-01-01

    Purpose: To evaluate acute cardiac effects of concurrent chemoradiotherapy (CCRT) for esophageal cancer. Methods and Materials: This prospective study was approved by the institutional review board, and written informed consent was obtained from all participants. The left ventricular function (LVF) of 31 patients with esophageal cancer who received cisplatin and 5-fluorouracil–based CCRT was evaluated using cardiac cine magnetic resonance imaging. The patients were classified into two groups according to mean LV dose. The parameters related to LVF were compared between before and during (40 Gy) or between before and after CCRT using a Wilcoxon matched-pairs single rank test, and parameter ratios (during/before CCRT, after/before CCRT) were also compared between the groups with a t test. Data were expressed as mean ± SE. Results: In the low LV-dose group (n = 10; mean LV dose 2 ), LV stroke volume index (38.6 ± 1.56 vs. 29.9 ± 1.60 mL/m 2 ), and LV ejection fraction (56.9% ± 1.79% vs. 52.8% ± 1.15%) decreased significantly (p < 0.05) after CCRT. Heart rate increased significantly (before vs. during vs. after CCRT; 66.8 ± 3.05 vs. 72.4 ± 4.04 vs. 85.4 ± 3.75 beats per minute, p < 0.01). Left ventricle wall motion decreased significantly (p < 0.05) in segments 8 (before vs. during vs. after CCRT; 6.64 ± 0.54 vs. 4.78 ± 0.43 vs. 4.79 ± 0.50 mm), 9 (6.88 ± 0.45 vs. 5.04 ± 0.38 vs. 5.27 ± 0.47 mm), and 10 (9.22 ± 0.48 vs. 8.08 ± 0.34 vs. 8.19 ± 0.56 mm). The parameter ratios of LV end-diastolic volume index, stroke volume index, wall motion in segment 9, and heart rate showed significant difference (p < 0.05) after CCRT between the groups. Conclusions: Concurrent chemoradiotherapy for esophageal cancer impairs LVF from an early treatment stage. This impairment is prominent in patients with high LV dose.

  17. Measurement of left ventricular torsion using block-matching-based speckle tracking for two-dimensional echocardiography

    Science.gov (United States)

    Sun, Feng-Rong; Wang, Xiao-Jing; Wu, Qiang; Yao, Gui-Hua; Zhang, Yun

    2013-01-01

    Left ventricular (LV) torsion is a sensitive and global index of LV systolic and diastolic function, but how to noninvasively measure it is challenging. Two-dimensional echocardiography and the block-matching based speckle tracking method were used to measure LV torsion. Main advantages of the proposed method over the previous ones are summarized as follows: (1) The method is automatic, except for manually selecting some endocardium points on the end-diastolic frame in initialization step. (2) The diamond search strategy is applied, with a spatial smoothness constraint introduced into the sum of absolute differences matching criterion; and the reference frame during the search is determined adaptively. (3) The method is capable of removing abnormal measurement data automatically. The proposed method was validated against that using Doppler tissue imaging and some preliminary clinical experimental studies were presented to illustrate clinical values of the proposed method.

  18. Diastolic dysfunction characterizes cirrhotic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Piyush O. Somani

    2014-11-01

    Conclusions: Present study shows that although diastolic dysfunction is a frequent event in cirrhosis, it is usually of mild degree and does not correlate with severity of liver dysfunction. There are no significant differences in echocardiographic parameters between alcoholic and non-alcoholic cirrhosis. HRS is not correlated to diastolic dysfunction in cirrhotic patients. There is no difference in survival at one year between patients with or without diastolic dysfunction. Diastolic dysfunction in cirrhosis is unrelated to circulatory dysfunction, ascites and HRS.

  19. Regional left ventricular myocardial contraction abnormalities and asynchrony in patients with hypertrophic cardiomyopathy evaluated by magnetic resonance spatial modulation of magnetization myocardial tagging

    International Nuclear Information System (INIS)

    Mishiro, Yuichiro; Oki, Takashi; Iuchi, Arata

    1999-01-01

    Global left ventricular (LV) pump function is generally preserved in patients with hypertrophic cardiomyopathy (HCM). However, it is unknown whether regional myocardial contractility is impaired, especially in nonhypertrophied regions. The purpose of this study was to evaluate regional LV myocardial contraction in patients with HCM using magnetic resonance (MR) spatial modulation of magnetization (SPAMM) myocardial tagging. The study group comprised 20 patients with asymmetric septal hypertrophy (HCM group) and 16 age-matched normal patients (control group), and data were collected using transthoracic M-mode and 2-dimensional echocardiography, and MR SPAMM myocardial tagging. The systolic strain ratio, maximum systolic strain velocity, and time from end-diastole to maximum systolic strain (ΔT) in the anterior, ventricular septal, inferior and lateral regions for 2 LV short-axis sections at the levels of the chordae tendineae and papillary muscles were measured at 50-ms intervals by MR myocardial tagging. The end-diastolic anterior and ventricular septal wall thicknesses and LV mass index were significantly different between the HCM and control groups. The systolic strain ratio for all 4 walls, particularly the anterior and ventricular septal regions, was significantly lower in the HCM group. In the HCM group, the maximum systolic strain velocity was significantly lower and ΔT was significantly shorter for all 4 walls, particularly the anterior and ventricular septal regions. The standard deviation for the ΔT, calculated from the ΔT for the 8 regions of the 2 LV short-axis sections, was significantly greater in the HCM group. In conclusion, regional LV myocardial contraction is impaired in both hypertrophied and nonhypertrophied regions, and systolic LV wall asynchrony occurs in patients with HCM. (author)

  20. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  1. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  2. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart diseases (preliminary report)

    International Nuclear Information System (INIS)

    Madeja, G.; Konieczna, S.; Gosiewska-Marcinkowska, E.; Leszek, P.

    1991-01-01

    In 15 patients with mitral valve defect and 10 patients with aortic valve defect, left ventricular end-diastolic and end-systolic volumes were determined by gated radionuclide angiography. The results were compared with contrast ventriculography. The correlation coefficient between the two methods was much lower in cases of mitral valve diseases. (author). 1 tab

  3. Layer-specific systolic and diastolic strain in  hypertensive patients with and without mild diastolic dysfunction

    Directory of Open Access Journals (Sweden)

    Hisham Sharif PhD

    2018-03-01

    Full Text Available This study sought to examine layer-specific longitudinal and circumferential systolic and diastolic strain, strain rate (SR and diastolic time intervals in hypertensive patients with and without diastolic dysfunction. Fifty-eight treated hypertensive patients were assigned to normal diastolic function (NDF, N = 39 or mild diastolic dysfunction (DD, N = 19 group. Layer-specific systolic and diastolic longitudinal and circumferential strains and SR were assessed. Results showed no between-group difference in left ventricular mass index (DD: 92.1 ± 18.1 vs NDF: 88.4 ± 16.3; P = 0.44. Patients with DD had a proportional reduction in longitudinal strain across the myocardium (endocardial for DD −13 ± 4%; vs NDF −17 ± 3, P < 0.01; epicardial for DD −10 ± 3% vs NDF −13 ± 3%, P < 0.01; global for DD: −12 ± 3% vs NDF: −15 ± 3, P = 0.01, and longitudinal mechanical diastolic impairments as evidenced by reduced longitudinal strain rate of early diastole (DD 0.7 ± 0.2 L/s vs NDF 1.0 ± 0.3 L/s, P < 0.01 and absence of a transmural gradient in the duration of diastolic strain (DD endocardial: 547 ± 105 ms vs epicardial: 542 ± 113 ms, P = 0.24; NDF endocardial: 566 ± 86 ms vs epicardial: 553 ± 77 ms, P = 0.03. Patients with DD also demonstrate a longer duration of early circumferential diastolic strain (231 ± 71 ms vs 189 ± 58 ms, P = 0.02. In conclusion, hypertensive patients with mild DD demonstrate a proportional reduction in longitudinal strain across the myocardium, as well as longitudinal mechanical diastolic impairment, and prolonging duration of circumferential mechanical relaxation.

  4. Changes in left atrial deformation in hypertrophic cardiomyopathy: Evaluation by vector velocity imaging

    Science.gov (United States)

    Badran, Hala Mahfouz; Soltan, Ghada; Hassan, Hesham; Nazmy, Ahmed; Faheem, Naglaa; Saadan, Haythem; Yacoub, Magdi H.

    2012-01-01

    Abstract: Objectives: Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. We assessed the global and regional left atrial (LA) function and its relation to left ventricular (LV) mechanics and clinical status in patients with HCM using Vector Velocity Imaging (VVI). Methods: VVI of the LA and LV was acquired from apical four- and two-chamber views of 108 HCM patients (age 40 ± 19years, 56.5% men) and 33 healthy subjects, all had normal LV systolic function. The LA subendocardium was traced to obtain atrial volumes, ejection fraction, velocities, and strain (ϵ)/strain rate (SR) measurements. Results: Left atrial reservoir (ϵsys,SRsys) and conduit (early diastolic SRe) function were significantly reduced in HCM compared to controls (P  − 1.8s− 1 was 81% sensitive and 30% specific, SRa> − 1.5s− 1 was 73% sensitive and 40% specific. By multivariate analysis global LVϵsys and LV septal thickness are independent predictors for LAϵsys, while end systolic diameter is the only independent predictor for SRsys, P < .001. Conclusion: Left atrial reservoir and conduit function as measured by VVI were significantly impaired while contractile function was preserved among HCM patients. Left atrial deformation was greatly influenced by LV mechanics and correlated to severity of phenotype. PMID:24688992

  5. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Schantz, Daryl I. [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); University of Manitoba, Variety Children' s Heart Centre, Winnipeg, MB (Canada); Dragulescu, Andreea [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); Memauri, Brett [University of Manitoba, Department of Radiology, St. Boniface General Hospital, Winnipeg, MB (Canada); Grotenhuis, Heynric B. [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); Wilhelmina Children' s Hospital, Utrecht (Netherlands); Seed, Mike; Grosse-Wortmann, Lars [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2016-10-15

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a ''variable'' that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient. (orig.)

  6. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers

    International Nuclear Information System (INIS)

    Schantz, Daryl I.; Dragulescu, Andreea; Memauri, Brett; Grotenhuis, Heynric B.; Seed, Mike; Grosse-Wortmann, Lars

    2016-01-01

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a ''variable'' that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient. (orig.)

  7. ACE inhibition with spirapril improves diastolic function at rest independent of vasodilation during treatment with spirapril in mild to moderate hypertension

    DEFF Research Database (Denmark)

    Petersen, J R; Drabaek, H; Gleerup, Christian Peter-Ole G.

    1996-01-01

    the patients entered three periods lasting four weeks each, wherein they were treated with placebo, spirapril, or hydrochlorothiazide. Blood pressure, hemodynamic variables (stroke volume, heart rate, cardiac output, index of contractility, and systemic vascular resistance), echocardiography (left ventricular...... mass), and Doppler-derived atrial to early (A/E)-ratio velocity time integrals (VTI) were measured at the end of each of the four periods. Spirapril lowered the A/E-ratio VTIs (0.57, 0.12-1.00) (P ... indicate that spirapril lowers A/E ratio within four weeks in patients with mild to moderate essential hypertension. It thereby seems able to improve left ventricular diastolic function. The effect is not dependent upon changes in hemodynamic variables, blood pressure, left ventricular mass, or end...

  8. Effects of auto-servo ventilation on patients with sleep-disordered breathing, stable systolic heart failure and concomitant diastolic dysfunction: subanalysis of a randomized controlled trial.

    Science.gov (United States)

    Birner, Christoph; Series, Frederic; Lewis, Keir; Benjamin, Amit; Wunderlich, Silke; Escourrou, Pierre; Zeman, Florian; Luigart, Ruth; Pfeifer, Michael; Arzt, Michael

    2014-01-01

    Systolic heart failure (HF) is frequently accompanied by diastolic dysfunction and sleep-disordered breathing (SDB). The objective of this subset analysis was to determine effect sizes of auto-servo ventilation (ASV and biphasic positive airway pressure ASV) on echocardiographic measures of diastolic function in patients with systolic HF and SDB. Thirty-two patients with stable systolic HF, concomitant diastolic dysfunction [age 66 ± 9 years old, left ventricular (LV) ejection fraction: 30 ± 7% and New York Heart Association class II: 72%] and SDB (apnea-hypopnea index, AHI: 48 ± 19/h; 53% had predominantly obstructive sleep apnea) receiving either ASV (n = 19) or optimal medical treatment (control, n = 13) were analyzed in a randomized controlled clinical trial. Polysomnographic and echocardiographic measurements were obtained at baseline and after 12 weeks. AHI significantly improved in the ASV group compared to the control group (-39 ± 18 vs. -0.2 ± 13.2/h, p control visit, diastolic function assessed by the isovolumetric relaxation time (-10.3 ± 26.1 vs. 9.3 ± 49.1, p = 0.48) and deceleration time (-43.9 ± 88.8 vs. 12.4 ± 68.8, p = 0.40) tended to improve after ASV treatment, but did not reach statistical significance. Likewise, the proportion of patients whose diastolic dysfunction improved was nonsignificantly higher in the ASV than in the control group, respectively (37 vs. 15%, p = 0.25). ASV treatment efficiently abolishes SDB in patients with stable systolic HF and concomitant diastolic dysfunction, and was associated with a statistically nonsignificant improvement in measures of diastolic dysfunction. Thus, these data provide estimates of effect size and justify the evaluation of the effects of ASV on diastolic function in larger randomized controlled trials. Copyright © 2013 S. Karger AG, Basel.

  9. Development of conductor feedthrough module of LV electrical penetration assembly for research reactors

    International Nuclear Information System (INIS)

    Luo Zhiyuan; Wang Guangjin; Zhou Bin

    2007-01-01

    A LV electrical penetration assembly with perfusion sealing conductor feedthrough module was developed, which can be used for the connection of internal and external cables through the wall of the research reactor workshop. The LV electrical penetration assembly was combined with several independent modules. The maintenance and replacement of the assembly can be easily done in service. The sealing of conductor feedthrough module was achieved with the perfusion of self-extinguishing epoxy. The leakage between the conductor feedthrough module and the end plate module was blocked with rubber rings. The result of the leakage test and the electrical performance test for the samples of conductor feedthrough module satisfied the requirement of research reactor. The structure of the new electrical penetration assembly is simple and compact. It can be manufactured with mature technology and cost low price. The performance of the assembly is steady. It can be used widely in research reactors. (authors)

  10. Changes in left ventricular systolic function in patients with chronic heart failure with preserved ejection fraction and cardiorenal anemic syndrome

    Directory of Open Access Journals (Sweden)

    Vasylenko V.A.

    2015-09-01

    Full Text Available The feature of chronic heart failure (CHF in elderly people is increasing incidence of heart failure with preserved left ventricular ejection fraction (LVEF which is associated with age. Such patients account for almost half of the total number of patients with heart failure. Cardiorenal syndrome (CRS is associated with an increased risk of mortality in patients with CHF. The impact of CRS on the structural and functional condition of the heart in these patients is studied insufficiently. The study involved 103 patients with CHF II-IV NYHA with preserved LVEF (>45% and CRS (hemoglobin <120 g/l and diastolic dysfunction development of concentric hypertrophy is observed, it is accompanied by deterioration of LV systolic function, namely by the increase of end-systolic volume and decrease in the degree of LV fractional shortening size.

  11. Measurement of left-to-right shunts by gated radionuclide angiography: concise communication

    International Nuclear Information System (INIS)

    Rigo, P.; Chevigne, M.

    1982-01-01

    Gated cardiac blood-pool scans allow comparison of left- and right-ventricular stroke volume. We have applied these measurements to the quantification of left-to-right shunts (QP/QS) in nine patients with atrial septal defects, one patients with partial anomalous pulmonary venous return, four patients with ventricular septal defects, and two patients with patent ductus arteriosus. None of these patients had combined lesions. QP/QS was measured as the right-ventricular (RV) stroke counts divided by the left-ventricular (LV) stroke counts and as the LV stroke counts divided by the RV stroke counts in patients with RV and LV diastolic volume overload respectively. All patients had also QP/QS measurements by oximetry and first-pass radionuclide angiography. The stroke-count measurements indicated the overloaded ventricle in all patients. QP/QS determined by equilibrium gated studies correlated well with those obtained by oximetry (r . 0.79). Reproducibility of the equilibrium measurements was good. We conclude that gated cardiac blood-pool scans can measure left-to-right shunts and can distinguish between shunts with RV and LV volume overload

  12. Vortex formation and instability in the left ventricle

    Science.gov (United States)

    Le, Trung Bao; Sotiropoulos, Fotis; Coffey, Dane; Keefe, Daniel

    2012-09-01

    We study the formation of the mitral vortex ring during early diastolic filling in a patient-specific left ventricle (LV) using direct numerical simulation. The geometry of the left ventricle is reconstructed from Magnetic Resonance Imaging (MRI) data of a healthy human subject. The left ventricular kinematics is modeled via a cell-based activation methodology, which is inspired by cardiac electro-physiology and yields physiologic LV wall motion. In the fluid dynamics videos, we describe in detail the three-dimensional structure of the mitral vortex ring, which is formed during early diastolic filling. The ring starts to deform as it propagates toward the apex of the heart and becomes inclined. The trailing secondary vortex tubes are formed as the result of interaction between the vortex ring and the LV wall. These vortex tubes wrap around the circumference and begin to interact with and destabilize the mitral vortex ring. At the end of diastole, the vortex ring impinges on the LV wall and the large-scale intraventricular flow rotates in clockwise direction. We show for the first time that the mitral vortex ring evolution is dominated by a number of vortex-vortex and vortex-wall interactions, including lateral straining and deformation of vortex ring, the interaction of two vortex tubes with unequal strengths, helicity polarization of vortex tubes and twisting instabilities of the vortex cores.

  13. Left ventricular remodeling in preclinical experimental mitral regurgitation of dogs.

    Science.gov (United States)

    Dillon, A Ray; Dell'Italia, Louis J; Tillson, Michael; Killingsworth, Cheryl; Denney, Thomas; Hathcock, John; Botzman, Logan

    2012-03-01

    Dogs with experimental mitral regurgitation (MR) provide insights into the left ventricular remodeling in preclinical MR. The early preclinical left ventricular (LV) changes after mitral regurgitation represent progressive dysfunctional remodeling, in that no compensatory response returns the functional stroke volume (SV) to normal even as total SV increases. The gradual disease progression leads to mitral annulus stretch and enlargement of the regurgitant orifice, further increasing the regurgitant volume. Remodeling with loss of collagen weave and extracellular matrix (ECM) is accompanied by stretching and hypertrophy of the cross-sectional area and length of the cardiomyocyte. Isolated ventricular cardiomyocytes demonstrate dysfunction based on decreased cell shortening and reduced intracellular calcium transients before chamber enlargement or decreases in contractility in the whole heart can be clinically appreciated. The genetic response to increased end-diastolic pressure is down-regulation of genes associated with support of the collagen and ECM and up-regulation of genes associated with matrix remodeling. Experiments have not demonstrated any beneficial effects on remodeling from treatments that decrease afterload via blocking the renin-angiotensin system (RAS). Beta-1 receptor blockade and chymase inhibition have altered the progression of the LV remodeling and have supported cardiomyocyte function. The geometry of the LV during the remodeling provides insight into the importance of regional differences in responses to wall stress. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Left ventricular volume determination from single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-01-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting

  15. Left ventricular volume determination from single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-02-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting.

  16. Evaluation of ECG-gated [(11)C]acetate PET for measuring left ventricular volumes, mass, and myocardial external efficiency.

    Science.gov (United States)

    Hansson, Nils Henrik; Tolbod, Lars; Harms, Johannes; Wiggers, Henrik; Kim, Won Yong; Hansen, Esben; Zaremba, Tomas; Frøkiær, Jørgen; Jakobsen, Steen; Sørensen, Jens

    2016-08-01

    Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P PET (P PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P PET-based MEE bias was strongly associated with LV wall thickness. Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.

  17. Studies on the synthesis of isotopes of superheavy element Lv (Z = 116)

    Energy Technology Data Exchange (ETDEWEB)

    Santhosh, K.P.; Safoora, V. [Kannur University, School of Pure and Applied Physics, Payyanur (India)

    2017-11-15

    The probable projectile-target combinations for the synthesis of superheavy nucleus {sup 296}Lv found in the cold valley of {sup 296}Lv have been identified by studying the interaction barrier of the colliding nuclei, probability of compound nucleus formation, P{sub CN}, and survival probability W{sub sur}. At energies near and above the Coulomb barrier, the capture, fusion and evaporation residue (ER) cross sections for the probable combinations for the hot and cold fusion reactions are systematically investigated. By considering intensities of the projectile beams, availabilities of the targets and half lives of the colliding nuclei, the combination {sup 48}Ca + {sup 248}Cm is found to be the most probable projectile-target pair for the synthesis of {sup 296}Lv. The calculated maximum value of 2n, 3n, 4n and 5n channel cross section for the reaction {sup 48}Ca + {sup 248}Cm are 0.599 pb, 5.957 pb, 4.805 pb, and 0.065 pb, respectively. Moreover, the production cross sections for the synthesis of isotopes {sup 291-295,298}Lv using {sup 48}Ca projectile on {sup 243-247,250}Cm targets are calculated. Among these reactions, the reactions {sup 48}Ca + {sup 247}Cm → {sup 295}Lv and {sup 48}Ca + {sup 250}Cm → {sup 298}Lv have maximum production cross section in 3n (10.697 pb) and 4n (12.006 pb) channel, respectively. Our studies on the SHE Lv using the combinations {sup 48}Ca + {sup 245}Cm → {sup 293}Lv and {sup 48}Ca + {sup 248}Cm → {sup 296}Lv are compared with available experimental data and with other theoretical studies. Our studies are in agreement with experimental data and we hope that these studies will be a guide for the future experiments to synthesize the isotopes of Lv. (orig.)

  18. Assessment of left ventricular function in patients with atrial fibrillation by left ventricular filling and function curves determined by ECG gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu

    1986-06-01

    Accurate cardiac function in patients with atrial fibrillation (Af) is difficult to assess, since a wide fluctuation of cardiac cycle makes the ventricular hemodynamics variable. Although ECG gated blood pool scintigraphy (EGBPS) is useful to evaluate left ventricular (LV) function, a conventional EGBPS might have a problem in applying to Af. Therefore, a new processing algorithm was devised to make multiple gated images discriminated by preceding R-R intervals (PRR), and LV filling and function curves were obtained in 62 patients with Af to evaluate LV function. LV filling curve, obtained by plotting end-diastolic volume (EDV) againt PRR, demonstrated that the blood filling was impaired in mitral stenosis and constrictive pericarditis, but recovered after mitral commissurotomy. LV function curve, by plotting stroke volume (SV) againt EDV, was quantitatively analysed by the indices such as Slope and Position. Both indices reduced significantly in heart failure. When compared among underlying diseases individually, the indices decreased in the following order; lone Af, hyperthyroidism, senile Af, hypertension, mitral valve disease, ischemic heart disease, dilated cardiomyopathy and aortic regurgitation. After the treatment with digitalis and/or diuretics, left and upward shift of function curve was observed. The rise in heart rate by atropine infusion made Slope and Position unchanged, and which implied that function curve was little influenced by heart rate per se. The rise in systolic blood pressure by angiotensin-II infusion caused shifts in function curve to rightward and downward. Downward shift, mostly seen in patients with gentler slope in control state, may imply afterload mismatch due to a decrease in preload reserve. (J.P.N.).

  19. Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function.

    Science.gov (United States)

    Goebel, Juliane; Nensa, Felix; Schemuth, Haemi P; Maderwald, Stefan; Gratz, Marcel; Quick, Harald H; Schlosser, Thomas; Nassenstein, Kai

    2016-08-01

    To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or high temporal resolution in comparison to a reference steady-state free precession cine (SSFP) sequence for reliable quantification of left ventricular (LV) volumes. LV short axis stacks of two compressed sensing breath-hold cine sequences with high spatial resolution (SPARSE-SENSE HS: temporal resolution: 40 msec, in-plane resolution: 1.0 × 1.0 mm(2) ) and high temporal resolution (SPARSE-SENSE HT: temporal resolution: 11 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) and of a reference cine SSFP sequence (standard SSFP: temporal resolution: 40 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) were acquired in 16 healthy volunteers on a 1.5T MR system. LV parameters were analyzed semiautomatically twice by one reader and once by a second reader. The volumetric agreement between sequences was analyzed using paired t-test, Bland-Altman plots, and Passing-Bablock regression. Small differences were observed between standard SSFP and SPARSE-SENSE HS for stroke volume (SV; -7 ± 11 ml; P = 0.024), ejection fraction (EF; -2 ± 3%; P = 0.019), and myocardial mass (9 ± 9 g; P = 0.001), but not for end-diastolic volume (EDV; P = 0.079) and end-systolic volume (ESV; P = 0.266). No significant differences were observed between standard SSFP and SPARSE-SENSE HT regarding EDV (P = 0.956), SV (P = 0.088), and EF (P = 0.103), but for ESV (3 ± 5 ml; P = 0.039) and myocardial mass (8 ± 10 ml; P = 0.007). Bland-Altman analysis showed good agreement between the sequences (maximum bias ≤ -8%). Two compressed sensing cine sequences, one with high spatial resolution and one with high temporal resolution, showed good agreement with standard SSFP for LV volume assessment. J. Magn. Reson. Imaging 2016;44:366-374. © 2016 Wiley Periodicals, Inc.

  20. Simultaneous determination of dynamic cardiac metabolism and function using PET/MRI.

    Science.gov (United States)

    Barton, Gregory P; Vildberg, Lauren; Goss, Kara; Aggarwal, Niti; Eldridge, Marlowe; McMillan, Alan B

    2018-05-01

    Cardiac metabolic changes in heart disease precede overt contractile dysfunction. However, metabolism and function are not typically assessed together in clinical practice. The purpose of this study was to develop a cardiac positron emission tomography/magnetic resonance (PET/MR) stress test to assess the dynamic relationship between contractile function and metabolism in a preclinical model. Following an overnight fast, healthy pigs (45-50 kg) were anesthetized and mechanically ventilated. 18 F-fluorodeoxyglucose ( 18 F-FDG) solution was administered intravenously at a constant rate of 0.01 mL/s for 60 minutes. A cardiac PET/MR stress test was performed using normoxic gas (F I O 2  = .209) and hypoxic gas (F I O 2  = .12). Simultaneous cardiac imaging was performed on an integrated 3T PET/MR scanner. Hypoxic stress induced a significant increase in heart rate, cardiac output, left ventricular (LV) ejection fraction (EF), and peak torsion. There was a significant decline in arterial SpO 2 , LV end-diastolic and end-systolic volumes in hypoxia. Increased LV systolic function was coupled with an increase in myocardial FDG uptake (Ki) during hypoxic stress. PET/MR with continuous FDG infusion captures dynamic changes in both cardiac metabolism and contractile function. This technique warrants evaluation in human cardiac disease for assessment of subtle functional and metabolic abnormalities.

  1. Age-related left ventricular remodeling and associated risk for cardiovascular outcomes: the Multi-Ethnic Study of Atherosclerosis.

    Science.gov (United States)

    Cheng, Susan; Fernandes, Verônica R S; Bluemke, David A; McClelland, Robyn L; Kronmal, Richard A; Lima, João A C

    2009-05-01

    Age-related alterations of left ventricular (LV) structure and function that may predispose to cardiovascular events are not well understood. We used cardiac MRI to examine age-related differences in LV structure and function in 5004 participants without overt cardiovascular disease when enrolled in the Multi-Ethnic Study of Atherosclerosis; 1099 participants received additional strain analyses by MRI tagging. We also assessed the relation of age-associated remodeling with cardiovascular outcomes using Cox proportional hazard models adjusting for cardiovascular risk factors. Although LV mass decreased with age (-0.3 g per year), the mass-to-volume ratio markedly increased (+5 mg/mL per year, Pfall in stroke volume (-0.4 mL per year, P or =65 years; hazard ratio, 1.68 [CI 0.77 to 3.68]) individuals with the highest compared to lowest mass-to-volume ratio quintile (P(interaction)=0.013). Age is associated with a phenotype of LV remodeling marked by increased mass-to-volume ratio and accompanied by systolic as well as diastolic myocardial dysfunction that is not reflected by preserved ejection fraction. This pattern of ventricular remodeling confers significant cardiovascular risk, particularly when present earlier in life.

  2. Relaxation and filling of the left ventricle assessed by Doppler echocardiography

    International Nuclear Information System (INIS)

    Myreng, Y.

    1990-01-01

    In patients with coronary disease the Doppler method described in the present work was capable of detecting a delayed left ventricular (LV) relaxation and a shift of LV filling from early towards late diastole. This might reflect changes in LV diastolic function due to myocardial ischemia. Furthermore, the method allowed monitoring of changes during treatment with atenolol and verapamil. These changes indicated that atenolol and verapamil were able to partially correct the relaxation abnormailty and increase the relative contribution of early diastolic filling. Although all the numerous variables that influence LV transmitral filling could be controlled in this noninvasive clinical study, the results suggest that antianginal drugs may have beneficial effect on diastolic function in coronary disease. 62 refs., 3 figs., 4 tabs

  3. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart disease

    International Nuclear Information System (INIS)

    Konieczna, S.; Madeja, G.; Gosiewska-Marcinkowska, E.; Szumilak, B.; Brodzki, L.M.; Leszek, P.

    1992-01-01

    The aim of this study was to investigate usability of the Massardo method in calculating the left ventricular volume in patients with valvular defect. The group consisted of 21 patients with mitral defect. Left ventricular volumes obtained by contrast ventriculography were used for reference. The correlation coefficient between these two methods was 0.94, SEE=29 ml, V nucl =0.94 V c.vent +11. The end-systolic and end-diastolic outlines were marked manually. We concluded that the Massardo methods is an effective method of calculating the left ventricular volume also in group of patients with mitral defect. (author). 11 refs, 4 tabs

  4. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2011-04-01

    Full Text Available Abstract Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking

  5. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    International Nuclear Information System (INIS)

    Töger, Johannes; Carlsson, Marcus; Söderlind, Gustaf; Arheden, Håkan; Heiberg, Einar

    2011-01-01

    Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR) can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking complements and provides incremental information compared to particle

  6. Cardiac resynchronization therapy by multipoint pacing improves response of left ventricular mechanics and fluid dynamics: a three-dimensional and particle image velocimetry echo study.

    Science.gov (United States)

    Siciliano, Mariachiara; Migliore, Federico; Badano, Luigi; Bertaglia, Emanuele; Pedrizzetti, Gianni; Cavedon, Stefano; Zorzi, Alessandro; Corrado, Domenico; Iliceto, Sabino; Muraru, Denisa

    2017-11-01

    To characterize the effect of multipoint pacing (MPP) compared to biventricular pacing (BiV) on left ventricle (LV) mechanics and intraventricular fluid dynamics by three-dimensional echocardiography (3DE) and echocardiographic particle imaging velocimetry (Echo-PIV). In 11 consecutive patients [8 men; median age 65 years (57-75)] receiving cardiac resynchronization therapy (CRT) with a quadripolar LV lead (Quartet,St.Jude Medical,Inc.), 3DE and Echo-PIV data were collected for each pacing configuration (CRT-OFF, BiV, and MPP) at follow-up after 6 months. 3DE data included LV volumes, LV ejection fraction (LVEF), strain, and systolic dyssynchrony index (SDI). Echo-PIV was used to evaluate the directional distribution of global blood flow momentum, ranging from zero, when flow force is predominantly along the base-apex direction, up to 90° when it becomes transversal. MPP resulted in significant reduction in end-diastolic and end-systolic volumes compared with both CRT-OFF (P = 0.02; P = 0.008, respectively) and BiV (P = 0.04; P = 0.03, respectively). LVEF and cardiac output were significant superior in MPP compared with CRT-OFF, but similar between MPP and BiV. Statistical significant differences when comparing global longitudinal and circumferential strain and SDI with MPP vs. CRT-OFF were observed (P = 0.008; P = 0.008; P = 0.01, respectively). There was also a trend towards improvement in strain between BiV and MPP that did not reach statistical significance. MPP reflected into a significant reduction of the deviation of global blood flow momentum compared with both CRT-OFF and BiV (P = 0.002) indicating a systematic increase of longitudinal alignment from the base-apex orientation of the haemodynamic forces. These preliminary results suggest that MPP resulted in significant improvement of LV mechanics and fluid dynamics compared with BiV. However, larger studies are needed to confirm this hypothesis. © Crown copyright 2016.

  7. Exercise-induced stunning continues for at least one hour: evaluation with quantitative gated single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Tsujimura, Eiichiro; Yamaguchi, Hitoshi; Tokita, Naoki; Maruyama, Atsushi; Xiuli, Mu; Nishimura, Tsunehiko [Division of Tracer Kinetics, Biomedical Research Center, Osaka University Medical School, Suita, Osaka (Japan)

    1999-04-29

    To elucidate the after-effect of exercise on left ventricular (LV) function, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were evaluated at 1 h after exercise and at rest by technetium-99m tetrofosmin gated myocardial single-photon emission tomography (SPET) using an automated program in 53 subjects. The subjects were grouped as follows: normal scan (n = 16), ischaemia (n = 19) and infarction (n = 18), based on the interpretation of perfusion images. Postexercise LVEF did not differ from resting LVEF in the groups with normal scan and infarction. In patients with ischaemia, postexercise EDV (90{+-}17 ml, mean {+-}SD) and ESV (44{+-}15 ml) were significantly higher than EDV (84{+-}15 ml, P = 0.001) and ESV (36{+-}14 ml, P<0.0005) at rest. LVEF was significantly depressed 1 h after exercise (53%{+-}9% vs 58%{+-}9%, P<0.0001). In ischaemic patients with depressed postexercise LVEF, LVEF difference between rest and postexercise showed a significant correlation with the sum of defect scores, which were reversible from exercise to rest perfusion images (r = 0.92, P<0.0001). These results indicate that exercise-induced LV dysfunction (myocardial stunning) continues for at least 1 h in ischaemic patients and that the extent of LVEF depression is determined by the severity of ischaemia. (orig.) With 7 figs., 19 refs.

  8. Exercise-induced stunning continues for at least one hour: evaluation with quantitative gated single-photon emission tomography

    International Nuclear Information System (INIS)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Tsujimura, Eiichiro; Yamaguchi, Hitoshi; Tokita, Naoki; Maruyama, Atsushi; Xiuli, Mu; Nishimura, Tsunehiko

    1999-01-01

    To elucidate the after-effect of exercise on left ventricular (LV) function, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were evaluated at 1 h after exercise and at rest by technetium-99m tetrofosmin gated myocardial single-photon emission tomography (SPET) using an automated program in 53 subjects. The subjects were grouped as follows: normal scan (n = 16), ischaemia (n = 19) and infarction (n = 18), based on the interpretation of perfusion images. Postexercise LVEF did not differ from resting LVEF in the groups with normal scan and infarction. In patients with ischaemia, postexercise EDV (90±17 ml, mean ±SD) and ESV (44±15 ml) were significantly higher than EDV (84±15 ml, P = 0.001) and ESV (36±14 ml, P<0.0005) at rest. LVEF was significantly depressed 1 h after exercise (53%±9% vs 58%±9%, P<0.0001). In ischaemic patients with depressed postexercise LVEF, LVEF difference between rest and postexercise showed a significant correlation with the sum of defect scores, which were reversible from exercise to rest perfusion images (r = 0.92, P<0.0001). These results indicate that exercise-induced LV dysfunction (myocardial stunning) continues for at least 1 h in ischaemic patients and that the extent of LVEF depression is determined by the severity of ischaemia. (orig.)

  9. Seismic monitoring during acid stimulation of wells LV-4 and LV-13 at the Las Tres Virgenes geothermal field, BCS, Mexico; Monitoreo sismico durante la estimulacion acida de los pozos LV-4 y LV-13 del campo geotermico de Las Tres Virgenes, BCS, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Venegas Salgado, Saul; Arredondo Fragoso, Jesus; Ramirez Silva, German; Flores Armenta, Magaly; Ramirez Montes, Miguel [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico)]. E-mail: magaly.flores@cfe.gob.mx

    2006-07-15

    From September through December 2004 a seismic monitoring in the Las Tres Virgenes, BCS, geothermal field was carried out simultaneously with the acid stimulation of wells LV-4 and LV-13. The seismic network had four digital seismographs and recorded 174 local seismic events, 131 regional ones and many more volcanic signals at seismic station TV20 during the acid stimulation. Additionally, 37 seismic events were located, 22 of them inside the most important geothermal zone at depths between 0.4 and 4 km with typically low magnitudes (0.7 to 2.2 Md). Two relevant zones were determined: Zone A related to the El Volcan fault system and Zone B related to injection well LV-8. In Zone A the well-induction stage and the operation start of the wells LV-4 and LV-13 after acidification on October 30 and November 17, 2004, increased seismic activity to a maximum of 12 daily events in early December. When the two wells in Zone B were cooled before the acidification, the seismic events recorded there increased to a maximum of 6 daily events on October 2, and then decreased. Also in Zone B the seismic activity increased after well-induction and the start of well production once they were acidified, recording up to 11 daily events in late November. According to the seismic distribution, we may conclude that the most active fault systems are El Volcan and El Viejo. New proposals for well locations in the field are supported by these results. [Spanish] De septiembre a diciembre de 2004 se realizo un estudio de monitoreo sismico en el campo geotermico de Las Tres Virgenes, BCS, simultaneamente con las estimulaciones acidas de los pozos LV-4 y LV-13. Se utilizo una red sismica conformada por cuatro sismografos digitales, logrando registrar en la estacion sismica TV20 un total de 174 sismos locales, 131 sismos regionales y muchas mas senales de tipo volcanico, durante el periodo del monitoreo de la estimulacion acida. Ademas, se localizaron un total de 37 sismos, de los cuales 22 se

  10. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease

    International Nuclear Information System (INIS)

    Bak, So Hyeon; Jeon, Hae Jeong; Ko, Sung Min; Yang, Hyun Suk; Hwang, Hweung Kon; Song, Meong Gun

    2012-01-01

    Background: Left ventricular (LV) function is a vital parameter for prognosis, therapy guidance, and follow-up of cardiovascular disease. Dual-source computed tomography (DSCT) provides an accurate analysis of global LV function. Purpose: To assess the performance of DSCT in the determination of global LV functional parameters in comparison with cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) in patients with valvular heart disease (VHD). Material and Methods: A total of 111 patients (58 men, mean age 49.9 years) with known VHD and who underwent DSCT, 2D-TTE, and CMR a period of 2 weeks before undergoing valve surgery were included in this study. LV end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were calculated by DSCT using the threshold-based technique, by 2D-TTE using a modified Simpson's method, and by CMR using Simpson's method. Agreement for parameters of LV global function was determined with the Pearson's correlation coefficient (r) and Bland-Altman analysis. All the DSCT and CMR data-sets were assessed independently by two readers. Results: Fifty of the total 111 patients had aortic VHD, 29 patients had mitral VHD, and 32 patients had mixed aortic and mitral VHD. An excellent inter-observer agreement was seen for the assessment of global LV function using DSCT (r 0.910-0.983) and CMR (r = 0.854-0.965). An excellent or good correlation (r 0.93, 0.95, 0.87, and 0.71, respectively, P < 0.001) was noted between the DSCT and 2D-TTE values for EDV, ESV, SV, and EF. EDV (33.7 mL, P < 0.001), ESV (12.1 mL, P < 0.001), SV (21.2 mL, P < 0.001), and EF (1.6%, P = 0.019) were significantly overestimated by DSCT when compared with 2D-TTE. An excellent correlation (r = 0.96, 0.97, 0.91, and 0.94, respectively, P < 0.001) between DSCT and CMR was seen in the evaluation of EDV, ESV, SV, and EF. EDV (15.9 mL, P < 0.001), ESV (7.3 mL, P < 0.001), and SV (8.5 mL, P < 0

  11. Preferential effects of low volume versus high volume replacement with crystalloid fluid in a hemorrhagic shock model in pigs.

    Science.gov (United States)

    Ponschab, Martin; Schöchl, Herbert; Keibl, Claudia; Fischer, Henrik; Redl, Heinz; Schlimp, Christoph J

    2015-10-06

    Fluid resuscitation is a core stone of hemorrhagic shock therapy, and crystalloid fluids seem to be associated with lower mortality compared to colloids. However, as redistribution starts within minutes, it has been suggested to replace blood loss with a minimum of a three-fold amount of crystalloids. The hypothesis was that in comparison to high volume (HV), a lower crystalloid volume (LV) achieves a favorable coagulation profile and exerts sufficient haemodynamics in the acute phase of resuscitation. In 24 anaesthetized pigs, controlled arterial blood loss of 50 % of the estimated blood volume was either (n = 12) replaced with a LV (one-fold) or a HV (three-fold) volume of a balanced, acetated crystalloid solution at room temperature. Hemodynamic parameters, dilution effects and coagulation profile by standard coagulation tests and thromboelastometry at baseline and after resuscitation were determined in both groups. LV resuscitation increased MAP significantly less compared to the HV, 61 ± 7 vs. 82 ± 14 mmHg (p controlled blood loss, a one fold LV crystalloid replacement strategy is sufficient to adequately raise blood pressure up to a mean arterial pressure >50 mm Hg. The concept of damage control resuscitation (DCR) with permissive hypotension may be better met by using LV as compared to a three fold HV resuscitation strategy. High volume administration of an acetated balanced crystalloid does not lead to hyperchloraemic acidosis, but may negatively influence clinical parameters, such as higher blood pressure, lower body temperature and impaired coagulation parameters, which could potentially increase bleeding after trauma. Replacement of acute blood loss with just an equal amount of an acetated balanced crystalloid appears to be the preferential treatment strategy in the acute phase after controlled bleeding.

  12. Intraventricular dyssynchrony in light chain amyloidosis: a new mechanism of systolic dysfunction assessed by 3-dimensional echocardiography

    Directory of Open Access Journals (Sweden)

    Truran Seth

    2008-08-01

    Full Text Available Abstract Background Light chain amyloidosis (AL is a rare but often fatal disease due to intractable heart failure. Amyloid deposition leads to diastolic dysfunction and often preserved ejection fraction. We hypothesize that AL is associated with regional systolic dyssynchrony. The aim is to compare left ventricular (LV regional synchrony in AL subjects versus healthy controls using 16-segment dyssynchrony index measured from 3-dimension-al (3D echocardiography. Methods Cardiac 3D echocardiography full volumes were acquired in 10 biopsy-proven AL subjects (60 ± 3 years, 5 females and 10 healthy controls (52 ± 1 years, 5 females. The LV was subdivided into 16 segments and the time from end-diastole to the minimal systolic volume for each of the 16 segments was expressed as a percent of the cycle length. The standard deviations of these times provided a 16-segment dyssynchrony index (16-SD%. 16-SD% was compared between healthy and AL subjects. Results Left ventricular ejection fraction was comparable (control vs. AL: 62.4 ± 0.6 vs. 58.6 ± 2.8%, p = NS. 16-SD% was significantly higher in AL versus healthy subjects (5.93 ± 4.4 vs. 1.67 ± 0.87%, p = 0.003. 16-SD% correlated with left ventricular mass index (R 0.45, p = 0.04 but not to left ventricular ejection fraction. Conclusion Light chain amyloidosis is associated with left ventricular regional systolic dyssynchrony. Regional dyssynchrony may be an unrecognized mechanism of heart failure in AL subjects.

  13. Left Ventricular Function After Prolonged Exercise in Equine Endurance Athletes

    DEFF Research Database (Denmark)

    Flethøj, M.; Schwarzwald, C. C.; Haugaard, M. M.

    2016-01-01

    Doppler imaging, and two-dimensional speckle tracking. Correlation between echocardiographic variables and cardiac troponin I was evaluated. Results: Early diastolic myocardial velocities decreased significantly in longitudinal (baseline: −17.4 ± 2.4cm/s; end of ride: −15.8 ± 3.2cm/s (P = .013); morning......Background: Prolonged exercise in human athletes is associated with transient impairment of left ventricular (LV) function, known as cardiac fatigue. Cardiac effects of prolonged exercise in horses remain unknown. Objectives :To investigate the effects of prolonged exercise on LV systolic...... and diastolic function in horses. Animals: Twenty-six horses competing in 120–160 km endurance rides. Methods: Cross-sectional field study. Echocardiography was performed before and after rides, and the following morning, and included two-dimensional echocardiography, anatomical M-mode, pulsed-wave tissue...

  14. Structural and functional changes in the heart and clinical features of heart failure with preserved left ventricular ejection fraction in patients after myocardial infarction, comorbided with arterial hypertension

    Directory of Open Access Journals (Sweden)

    V. D. Syvolap

    2013-12-01

    class I, 32% - NYHA class II, 48% - NYHA class III and 10% have NYHA class IV. In the first group revealed a significant increase of left ventricular end diastolic volume (13,8%, p <0,05, left ventricular end systolic volume (14,9%, p <0,05 and left atrial volume index (35%, p <0,05 compared with patients from the second group. Patients from the second group had a significant increase of left ventricular mass index (15,2%, p <0,05, left ventricular posterior wall ( 12,8%, p <0,05 and interventricular septum (10%, p <0,05 compared with patients from the third group. Patients from the first group had a higher E/E ' ratio (26%, p <0,05 compared with patients from the second group. In patients from the second group revealed decreased E/A (30,8%, p <0,05, E '(35,7%, p <0,05 and increased E/E' (13, 3%, p <0,05 compared with patients from the third group. Patients after myocardial infarction with arterial hypertension and diastolic heart failure had diastolic dysfunction mainly on the type of violation of relaxation (74%. 22% of these patients had pseudonormal type of diastolic dysfunction and 4% had restrictive LV filling type. Conclusion: In patients with post-infarction cardiosclerosis and diastolic heart failure with arterial hypertension severity of clinical manifestations of heart failure correlates with left atrial volume index and markers of diastolic dysfunction such as E' and E/E'. In patients with post-infarction cardiosclerosis and arterial hypertension with diastolic heart failure had predominantly concentric hypertrophy with increased left atrial volume index and moderate left ventricular dilatation and mild diastolic dysfunction. In patients after myocardial infarction with arterial hypertension and asymptomatic diastolic dysfunction observed structural and functional changes in the type of concentric hypertrophy with thickened walls and increased left ventricular mass index.

  15. Significance of left ventricular volume measurement after heart transplantation using radionuclide techniques

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.; Boniaszczuk, J.

    1985-01-01

    Multigated equilibrium blood pool scanning using Technetium 99m labeled red blood cells was used to measure left ventricular volumes in three heterotopic and one orthotopic heart transplant recipient(s). Simultaneously, an endomyocardial biopsy was performed and the degree of acute rejection was assessed by a histological scoring system. The scores were correlated to changes in ejection fraction and heart rate. Technetium 99m scanning data were pooled according to the endomyocardial biopsy score: no rejection; mild rejection; moderate rejection, and severe rejection. In each group, the median of the left ventricular volume parameters was calculated and correlated with the endomyocardial biopsy score, using a non-parametric one-way analysis of variance. A decrease in stroke volume correlated best with the endomyocardial biopsy score during acute rejection. A decrease in end-diastolic left ventricular volumes did not correlate as well. Changes in the end-systolic left ventricular volumes were not statistically significant, but using a simple correlation between end-systolic left ventricular volumes and endomyocardial biopsy the correlation reached significance. Changes in left ventricular volumes measured by Technetium 99m scanning may be useful to confirm the presence or absence of acute rejection in patients with heart grafts

  16. Evaluation of methods for MR imaging of human right ventricular heart volumes and mass

    International Nuclear Information System (INIS)

    Jauhiainen, T.; Jaervinen, V.M.; Hekali, P.E.

    2002-01-01

    Purpose: To assess the utility of two different imaging directions in the evaluation of human right ventricular (RV) heart volumes and mass with MR imaging; to compare breath-hold vs. non-breath-hold imaging in volume analysis; and to compare turbo inversion recovery imaging (TIR) with gradient echo imaging in RV mass measurement. Material and Methods: We examined 12 healthy volunteers (age 27-59 years). Breath-hold gradient echo MR imaging was performed in two imaging planes: 1) perpendicular to the RV inflow tract (RVIT view), and 2) in the transaxial view (TA view). The imaging was repeated in the TA view while the subjects were breathing freely. To analyze RV mass using TIR images, the RV was again imaged at end-diastole using the two views. The RV end-diastolic cavity (RVEDV) and muscle volume as well as end-systolic cavity volume (RVESV) were determined with the method of discs. All measurements were done blindly twice to assess repeatability of image analysis. To assess reproducibility of the measurements, 6 of the subjects were imaged twice at an interval of 5-9 weeks. Results: RVEDV averaged 133.2 ml, RVESV 61.5 ml and the RVmass 46.2 g in the RVIT view and 119.9 ml, 56.9 ml and 38.3 g in the TA view, respectively. The volumes obtained with breath-holding were slightly but not significantly smaller than the volumes obtained during normal breathing. There were no marked differences in the RV muscle mass obtained with gradient echo imaging compared to TIR imaging in either views. Repeatability of volume analysis was better in TA than RVIT view: the mean differences were 0.7±4.0 ml and 5.4±14.0 ml in end-diastole and 1.6±3.1 ml and 1.5±13.9 ml in end-systole, respectively. Repeatability of mass analysis was good in both TIR and cine images in the RVIT view but slightly better in TIR images: 0.5±2.4 g compared to 0.8±2.9 g in cine images. Reproducibility of imaging was good, mean differences for RVEDV and RVESV were 1.0±4.8 ml and 0.8±2.8 ml

  17. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance

    International Nuclear Information System (INIS)

    Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M. Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian

    2008-01-01

    Objectives: To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Methods: Thirty-two consecutive patients (mean age, 56.5 ± 9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48 h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and κ-statistics. Results: The 64-slice MSCT agreed well with CMR for assessment of LVEF (r = 0.92; p < 0.0001), LVdV (r = 0.98; p < 0.0001) and LVsV (r = 0.98; p < 0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r = 0.84; p < 0.0001), LVdV (r = 0.83; p < 0.0001) and LVsV (r = 0.80; p < 0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (κ = 0.89 versus 0.63) with CMR. Conclusion: 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT

  18. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Annuar, Bin Rapaee [Faculty of Medicine, University Malaysia Sarawak (Malaysia); Department of Cardiology, Sarawak General Hospital (Malaysia)], E-mail: rannuar@fmhs.unimas.my; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam [Department of Cardiology, Sarawak General Hospital (Malaysia); Seyfarth, M. Tobias [Sieman Medical Solution (Germany); Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat [Department of Cardiology, Sarawak General Hospital (Malaysia); Lin, Naing [Universiti Sains Malaysia (Malaysia); Liew, Houng Bang; Sim, Kui Hian [Department of Cardiology, Sarawak General Hospital (Malaysia)

    2008-01-15

    Objectives: To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Methods: Thirty-two consecutive patients (mean age, 56.5 {+-} 9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48 h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and {kappa}-statistics. Results: The 64-slice MSCT agreed well with CMR for assessment of LVEF (r = 0.92; p < 0.0001), LVdV (r = 0.98; p < 0.0001) and LVsV (r = 0.98; p < 0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r = 0.84; p < 0.0001), LVdV (r = 0.83; p < 0.0001) and LVsV (r = 0.80; p < 0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement ({kappa} = 0.89 versus 0.63) with CMR. Conclusion: 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.

  19. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: a comparison with cardiac magnetic resonance.

    Science.gov (United States)

    Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian

    2008-01-01

    To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Thirty-two consecutive patients (mean age, 56.5+/-9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and kappa-statistics. The 64-slice MSCT agreed well with CMR for assessment of LVEF (r=0.92; p<0.0001), LVdV (r=0.98; p<0.0001) and LVsV (r=0.98; p<0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r=0.84; p<0.0001), LVdV (r=0.83; p<0.0001) and LVsV (r=0.80; p<0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (kappa=0.89 versus 0.63) with CMR. 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.

  20. Inferring microbial interaction networks from metagenomic data using SgLV-EKF algorithm.

    Science.gov (United States)

    Alshawaqfeh, Mustafa; Serpedin, Erchin; Younes, Ahmad Bani

    2017-03-27

    Inferring the microbial interaction networks (MINs) and modeling their dynamics are critical in understanding the mechanisms of the bacterial ecosystem and designing antibiotic and/or probiotic therapies. Recently, several approaches were proposed to infer MINs using the generalized Lotka-Volterra (gLV) model. Main drawbacks of these models include the fact that these models only consider the measurement noise without taking into consideration the uncertainties in the underlying dynamics. Furthermore, inferring the MIN is characterized by the limited number of observations and nonlinearity in the regulatory mechanisms. Therefore, novel estimation techniques are needed to address these challenges. This work proposes SgLV-EKF: a stochastic gLV model that adopts the extended Kalman filter (EKF) algorithm to model the MIN dynamics. In particular, SgLV-EKF employs a stochastic modeling of the MIN by adding a noise term to the dynamical model to compensate for modeling uncertainties. This stochastic modeling is more realistic than the conventional gLV model which assumes that the MIN dynamics are perfectly governed by the gLV equations. After specifying the stochastic model structure, we propose the EKF to estimate the MIN. SgLV-EKF was compared with two similarity-based algorithms, one algorithm from the integral-based family and two regression-based algorithms, in terms of the achieved performance on two synthetic data-sets and two real data-sets. The first data-set models the randomness in measurement data, whereas, the second data-set incorporates uncertainties in the underlying dynamics. The real data-sets are provided by a recent study pertaining to an antibiotic-mediated Clostridium difficile infection. The experimental results demonstrate that SgLV-EKF outperforms the alternative methods in terms of robustness to measurement noise, modeling errors, and tracking the dynamics of the MIN. Performance analysis demonstrates that the proposed SgLV-EKF algorithm

  1. Effect of vildagliptin, a dipeptidyl peptidase 4 inhibitor, on cardiac hypertrophy induced by chronic beta-adrenergic stimulation in rats

    Science.gov (United States)

    2014-01-01

    Background Heart failure with left ventricular (LV) hypertrophy is often associated with insulin resistance and inflammation. Recent studies have shown that dipeptidyl peptidase 4 (DPP4) inhibitors improve glucose metabolism and inflammatory status. We therefore evaluated whether vildagliptin, a DPP4 inhibitor, prevents LV hypertrophy and improves diastolic function in isoproterenol-treated rats. Methods Male Wistar rats received vehicle (n = 20), subcutaneous isoproterenol (2.4 mg/kg/day, n = 20) (ISO), subcutaneous isoproterenol (2.4 mg/kg/day + oral vildagliptin (30 mg/kg/day, n = 20) (ISO-VL), or vehicle + oral vildagliptin (30 mg/kg/day, n = 20) (vehicle-VL) for 7 days. Results Blood pressure was similar among the four groups, whereas LV hypertrophy was significantly decreased in the ISO-VL group compared with the ISO group (heart weight/body weight, vehicle: 3.2 ± 0.40, ISO: 4.43 ± 0.39, ISO-VL: 4.14 ± 0.29, vehicle-VL: 3.16 ± 0.16, p vildagliptin lowered the elevated LV end-diastolic pressure observed in the ISO group, but other parameters regarding LV diastolic function such as the decreased minimum dp/dt were not ameliorated in the ISO-VL group. Histological analysis showed that vildagliptin attenuated the increased cardiomyocyte hypertrophy and perivascular fibrosis, but it did not affect angiogenesis in cardiac tissue. In the ISO-VL group, quantitative PCR showed attenuation of increased mRNA expression of tumor necrosis factor-α, interleukin-6, insulin-like growth factor-l, and restoration of decreased mRNA expression of glucose transporter type 4. Conclusions Vildagliptin may prevent LV hypertrophy caused by continuous exposure to isoproterenol in rats. PMID:24521405

  2. Cardiac magnetic resonance imaging for evaluation of non-compaction cardiomyopathy in patients with or without left ventricular systolic dysfunction

    International Nuclear Information System (INIS)

    Deviggiano, A.; Deschle, H.; Lewkowicz, J.M.; Tajer, C.D.; Carrascosa, P.; Capunay, C.; Vallejos, J.; Stewart Harris, A.

    2011-01-01

    Background: Non-compaction cardiomyopathy (NCC) is a genetic disorder characterized by deep trabeculations in the ventricular wall, which define recesses communicating with the main ventricular chamber. The prevalence of NCC is greater in symptomatic populations with left ventricular dysfunction; yet, it may also be detected in asymptomatic patients with normal left ventricular function using novel diagnostic tools. However, this condition is under-diagnosed due to a low index of clinical suspicion and to the use of echocardiography classifications based on different diagnostic criteria. The use of cardiac magnetic resonance imaging (CMRI) has established two diagnostic criteria that clearly recognize this disease. Objective: To evaluate the clinical and morphological characteristics of patients with NCC with and without systolic dysfunction undergoing cardiac magnetic resonance imaging (CMRI). Material and Methods: A total of 20 patients with NCC were retrospectively included. The following parameters were determined: left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV); left ventricular end-diastolic diameter (LVEDD); left ventricular end-systolic diameter (LVESD); cardiac mass and left ventricular trabeculations. The distribution of NC myocardium was evaluated according to the model of 17 myocardial segments. Results: Mean myocardial thickness was 13.1 ± 3.3 mm and 3.6 ± 0.6 mm in NC versus normal myocardium, respectively. Patients with left ventricular dysfunction presented increased LVEDD, LVEDV, total cardiac mass, and LV non-compaction and trabeculations. We found a positive correlation and a linear relationship between LVEDD and TLVM (g/m 2 ): r=0.76; r 2 =0.59; p [es

  3. Validation of rest and exercise radionuclide angiography in patients with aortic regurgitation

    International Nuclear Information System (INIS)

    Gosiewska-Marcinkowska, E.; Rawczynska-Englert, I.; Szumilak, B.; Konieczna, S.; Rozycka-Chrzanowska, B.

    1992-01-01

    The aim of the study was to evaluate the significance of rest and stress test using radionuclide angiography (RA) in assessment of left ventricular (LV) function in the patients with aortic regurgitation (AR). In 32 patients we analyzed pre and 12 months after aortic valve replacement (AVR) the clinical data (including LV cavity dimension, LV hypertrophy, relative heart volume - RHV, the value of diastolic pressure) and the RA at rest and during supine stress test. We compared the clinical data with eject fraction (EF) and rest (EFr), at exercise (EFex) and ΔEF=EFex-EFr. Results show good correlation between clinical data and EF. Conclusions: 1) exercise RA is an useful method of estimation of LV function and after AVR; 2) early evaluation of the reserve of the LV allows to establish the appropriate time for AVR even before the signs of insufficiency of the LV are revealed. (author). 8 refs, 2 tabs

  4. Effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 on the left ventricular pressure-volume relationship in the halothane-anesthetized dogs.

    Science.gov (United States)

    Honda, Atsushi; Nakamura, Yuji; Ohara, Hiroshi; Cao, Xin; Nomura, Hiroaki; Katagi, Jun; Wada, Takeshi; Izumi-Nakaseko, Hiroko; Ando, Kentaro; Sugiyama, Atsushi

    2016-03-15

    Cardiac effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 were assessed in the halothane-anesthetized dogs under the monitoring of left ventricular pressure-volume relationship, which were compared with those of clinically recommended doses of dopamine, dobutamine and milrinone (n=4-5 for each treatment). ONO-AE1-329 was intravenously administered in doses of 0.3, 1 and 3 ng/kg/min for 10 min with a pause of 20 min. Dopamine in a dose of 3 µg/kg/min for 10 min, dobutamine in a dose of 1 µg/kg/min for 10 min and milrinone in a dose of 5 µg/kg/min for 10 min followed by 0.5 µg/kg/min for 10 min were intravenously administered. Low dose of ONO-AE1-329 increased the stroke volume. Middle dose of ONO-AE1-329 increased the cardiac output, left ventricular end-diastolic volume, ejection fraction, maximum upstroke/downstroke velocities of the left ventricular pressure and external work, but decreased the end-systolic pressure and internal work besides the change by the low dose. High dose of ONO-AE1-329 increased the heart rate and maximum elastance, but decreased the end-systolic volume besides the changes by the middle dose. Dopamine, dobutamine and milrinone exerted essentially similar cardiac effects to ONO-AE1-329, but they did not significantly change the end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, end-systolic pressure, maximum elastance, external work or internal work. Thus, EP4-receptor stimulation by ONO-AE1-329 may have potential to better promote the passive ventricular filling than the conventional cardiotonic drugs, which could become a candidate of novel therapeutic strategy for the treatment of heart failure with preserved ejection fraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Left ventricular wall stress and sarcoplasmic reticulum Ca(2+)-ATPase gene expression in renal hypertensive rats: dose-dependent effects of ACE inhibition and AT1-receptor blockade.

    Science.gov (United States)

    Zierhut, W; Studer, R; Laurent, D; Kästner, S; Allegrini, P; Whitebread, S; Cumin, F; Baum, H P; de Gasparo, M; Drexler, H

    1996-05-01

    Cardiac hypertrophy is associated with altered Ca2+ handling and may predispose to the development of LV dysfunction and cardiac failure. At the cellular level, the re-expression of ANF represents a well-established marker of myocyte hypertrophy while the decreased expression of the sarcoplasmatic reticulum (SR) Ca(2+)-ATPase is thought o play a crucial role in the alterations of Ca2+ handling and LV function. We assessed the dose-dependent effect of chronic ACE inhibition or AT1 receptor blockade on cardiac function in relation to the cardiac expression of the SR Ca(2+)-ATPase and ANF. Renal hypertensive rats (2K-1C) were treated for 12 weeks with three different doses of the ACE inhibitor benazepril, the AT1-receptor antagonist valsartan (each drug 0.3, 3, and 10 mg/kg per day i.p.) or placebo. LV dimensions, hypertrophy and wall stress were determined in vivo by magnetic resonance imaging and the gene expressions of ANF and SR Ca(2+)-ATPase were quantified by Northern blot. Low doses of both drugs did not affect blood pressure, hypertrophy, systolic wall stress and the ANF and SR Ca(2+)-ATPase gene expression. High doses of each drug reduced systolic blood pressure, wall stress, and LV hypertrophy to a similar extent and to values comparable to normotensive, age-matched rats. In addition, high dose treatment reduced LV end-systolic and end-diastolic volume as compared to untreated 2K-1C animals and normalized the mRNA levels of both ANF and SR Ca(2+)-ATPase (as compared to normotensive animals). We conclude that in this model, high doses of ACE inhibition and AT1-receptor blockade are necessary to normalize systolic blood pressure, LV hypertrophy and systolic LV wall stress which, in turn, is associated with restoration of a normal cardiac phenotype with respect to SR Ca(2+)-ATPase and ANF and normalization of cardiac function.

  6. Real-Time Three-Dimensional Echocardiography of the Left Ventricle-Pediatric Percentiles and Head-to-Head Comparison of Different Contour-Finding Algorithms: A Multicenter Study.

    Science.gov (United States)

    Krell, Kristina; Laser, Kai Thorsten; Dalla-Pozza, Robert; Winkler, Christian; Hildebrandt, Ursula; Kececioglu, Deniz; Breuer, Johannes; Herberg, Ulrike

    2018-03-28

    Real-time three-dimensional echocardiography (RT3DE) is a promising method for accurate assessment of left ventricular (LV) volumes and function, however, pediatric reference values are scarce. The aim of the study was to establish pediatric percentiles in a large population and to compare the inherent influence of different evaluation software on the resulting measurements. In a multicenter prospective-design study, 497 healthy children (ages 1 day to 219 months) underwent RT3DE imaging of the LV (ie33, Philips, Andover, MA). Volume analysis was performed using QLab 9.0 (Philips) and TomTec 4DLV2.7 (vendor-independent; testing high (TomTec 75 ) and low (TomTec 30 ) contour-finding activity). Reference percentiles were computed using Cole's LMS method. In 22 subjects, cardiovascular magnetic resonance imaging (CMR) was used as the reference. A total of 370/497 (74.4%) of the subjects provided adequate data sets. LV volumes had a significant association with age, body size, and gender; therefore, sex-specific percentiles were indexed to body surface area. Intra- and interobserver variability for both workstations was good (relative bias ± SD for end-diastolic volume [EDV] in %: intraobserver: QLab = -0.8 ± 2.4; TomTec 30  = -0.7 ± 7.2; TomTec 75  = -1.9 ± 6.7; interobserver: QLab = 2.4 ± 7.5; TomTec 30  = 1.2 ± 5.1; TomTec 75  = 1.3 ± 4.5). Intervendor agreement between QLab and TomTec 30 showed larger bias and wider limits of agreement (bias: QLab vs TomTec 30 : end-systolic volume [ESV] = 0.8% ± 23.6%; EDV = -2.2% ± 17.0%) with notable individual differences in small children. QLab and TomTec underestimated CMR values, with the highest agreement between CMR and QLab. RT3DE allows reproducible noninvasive assessment of LV volumes and function. However, intertechnique variability is relevant. Therefore, our software-specific percentiles, based on a large pediatric population, serve as a reference for both commonly used

  7. Treating myocardial stunning randomly, with either propofol or isoflurane following transient coronary occlusion and reperfusion in pigs

    Directory of Open Access Journals (Sweden)

    Urdaneta Felipe

    2009-01-01

    Full Text Available Propofol and isoflurane may be used during fast track anesthesia for off-pump bypass, where transient ischemia is common. The purpose of this study was to compare the effects of propofol vs isoflurane in a porcine model of acute coronary occlusion. Twenty five pigs were randomized to receive general anesthesia with either isoflurane, 1 MAC (n = 13, or propofol, 3 mg/kg bolus followed by 200 μg/ kg/min infusion (n = 12. Pressure-tipped catheters were placed in the left ventricle (LV and carotid artery; cardiac output was measured by ultrasound; two pairs of ultrasonic dimension catheters were placed in the subendocardium of LV. The slope of LV end-systolic pressure-volume relationship (E max was calculated. Reversible ischemia for 15 mins was accomplished with an occluder around the left anterior descending artery followed by reperfusion period. Measurements were done at baseline, end ischemia, early (5 min and late (30 min reperfusion. The data collected included systemic hemodynamics, LV end-diastolic pressure (LVEDP, dP/dt, E max , and the presence of ventricular arrhythmias. The number of animals studied to completion was 19 (n = 11 in the isoflurane group; n = 8 in propofol group. There was a significant difference in E max between isoflurane and propofol during early and late reperfusion [3.4 (0.5 and 4.0 (0.3 vs 2.6 (0.4 and 3.2 (0.5 mmHg/sec, respectively; P < 0.05]. Postreperfusion ventricular fibrillation occurred in 54% animals in the propofol group vs none in the isoflurane group ( P < 0.05. Isoflurane administration was found to be cardioprotective against ventricular depression and arrhythmias compared to propofol.

  8. Elevated plasma levels of TNF-alpha and Interleukin-6 in patients with diastolic dysfunction and glucose metabolism disorders

    Directory of Open Access Journals (Sweden)

    Ellinghaus Peter

    2009-11-01

    Full Text Available Abstract Background Diabetes mellitus (DM has reached epidemic proportions and is an important risk factor for heart failure (HF. Left ventricular diastolic dysfunction (LVDD is recognized as the earliest manifestation of DM-induced LV dysfunction, but its pathophysiology remains incompletely understood. We sought to evaluate the relationship between proinflammatory cytokine levels (TNF-alpha, IL-6 and tissue Doppler derived indices of LVDD in patients with stable coronary artery disease. Methods We enrolled 41 consecutive patients (mean age 65+/-10 years submitted for coronary angiography. Echocardiographic assessment was performed in all patients. Pulsed tissue Doppler imaging was performed at the mitral annulus and was characterized by the diastolic early relaxation velocity Em. Conventional transmitral flow was measured with pw-doppler. Early (E transmitral flow velocity was measured. LVDD was defined as E/Em ratio ≥ 15, E/Em 8-14 was classified as borderline. Plasma levels of TNF-alpha and IL-6 were determined in all patients. A standardized oral glucose tolerance test was performed in subjects without diabetes. Results Patients with E/Em ratio ≥ 15, classified as LVDD and those with E/Em ratio 8-14 (classified as borderline had significantly higher IL-6 (P = 0,001, TNF-alpha (P Conclusion This study reveals that increased plasma levels of IL-6 and TNF-alpha were associated with LVDD. These findings suggest a link between low-grade inflammation and the presence of LVDD. An active proinflammatory process may be of importance in the pathogenesis of diastolic dysfunction.

  9. LV reverse remodeling imparted by aortic valve replacement for severe aortic stenosis; is it durable? A cardiovascular MRI study sponsored by the American Heart Association

    Directory of Open Access Journals (Sweden)

    Caruppannan Ketheswaram

    2011-04-01

    Full Text Available Abstract Background In patients with severe aortic stenosis (AS, long-term data tracking surgically induced effects of afterload reduction on reverse LV remodeling are not available. Echocardiographic data is available short term, but in limited fashion beyond one year. Cardiovascular MRI (CMR offers the ability to serially track changes in LV metrics with small numbers due to its inherent high spatial resolution and low variability. Hypothesis We hypothesize that changes in LV structure and function following aortic valve replacement (AVR are detectable by CMR and once triggered by AVR, continue for an extended period. Methods Tweny-four patients of which ten (67 ± 12 years, 6 female with severe, but compensated AS underwent CMR pre-AVR, 6 months, 1 year and up to 4 years post-AVR. 3D LV mass index, volumetrics, LV geometry, and EF were measured. Results All patients survived AVR and underwent CMR 4 serial CMR's. LVMI markedly decreased by 6 months (157 ± 42 to 134 ± 32 g/m2, p 2. Similarly, EF increased pre to post-AVR (55 ± 22 to 65 ± 11%,(p 2. LV stroke volume increased rapidly from pre to post-AVR (40 ± 11 to 44 ± 7 ml, p Conclusion After initial beneficial effects imparted by AVR in severe AS patients, there are, as expected, marked improvements in LV reverse remodeling. Via CMR, surgically induced benefits to LV structure and function are durable and, unexpectedly express continued, albeit markedly incomplete improvement through 4 years post-AVR concordant with sustained improved clinical status. This supports down-regulation of both mRNA and MMP activity acutely with robust suppression long term.

  10. Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling

    International Nuclear Information System (INIS)

    Heilmaier, Christina; Nassenstein, Kai; Nielles-Vallespin, Sonia; Zuehlsdorff, Sven; Hunold, Peter; Barkhausen, Joerg

    2010-01-01

    Purpose: To prospectively assess the performance of highly accelerated cine MRI in multi-orientations combined with a new guide-point modeling post-processing technique (GPM approach) for assessment of left ventricular (LV) function compared to the standard summation of slices method based on a stack of short axis views (SoS approach). Materials and methods: 33 consecutive patients were examined on a 1.5 T scanner with a standard steady state free precession (SSFP) sequence (TR, 3.0 ms; TE, 1.5 m; flip angle (FA), 60 o ; acceleration factor (AF), 2) analyzed with the SoS method and a highly accelerated, single breath-hold temporal parallel acquisition SSFP sequence (TR, 4.6 ms; TE, 1.1 ms; AF, 3) post-processed with the GPM method. LV function values were measured by two independent readers with different experience in cardiac MRI and compared by using the paired t-test and F-test. Inter- and intraobserver agreements were calculated using Bland-Altman-Plots. Results: Mean acquisition and post-processing time was significantly shorter with the GPM approach (15 s/3 min versus 360 s/6 min). For all LV function parameters interobserver agreement between the experienced and non-experienced reader was significantly improved when the GPM approach was used. However, end-diastolic and end-systolic volumes were larger for the GPM technique when compared to the SoS method (P 0.121). In both readers and for all parameters variances did not differ significantly (P ≥ 0.409) and the two approaches showed an excellent linear correlation (r > 0.951). Conclusion: Due to its accurate, fast and reproducible assessment of LV function parameters highly accelerated MRI combined with the GPM technique may become the technique of first choice for assessment of LV function in clinical routine.

  11. Assessment of various systolic phase indexes for the detection of coronary artery disease by multi-gated blood pool imaging at rest

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru; Kanao, Keisuke

    1982-01-01

    After Tc-99m was labeled with red blood cells in vivo, multi-gated blood pool imaging (MGBPI) was obtained at anterior and 40-degree left anterior oblique (LAO) position at rest. In addition to left ventricular (LV) ejection fraction (EF) and wall motion (WM) abnormality, first-third EF, mean normalized systolic ejection rate, SdV/dt/EDV (LV peak ejection rate normalized by end-diastolic volume) and SdV/dt/V (peak ejection rate normalized by LV volume at the peak ejection) were calculated. Patients were divided into 3 groups; Normal (n = 14), coronary artery disease (CAD) with normal EF (> = 55%) and normal WM (Group I, n = 16), and CAD with abnormal EF and/or WM abnormality (Group II, n = 31). In all subjects of Normal and 13 patients of Group I, graded supine exercise stress MGBPI was performed at LAO position by using bicycle ergometer. All systolic phase indexes were correlated well with EF (r > = 0.77, p - 1 , p - 1 as a criteria of CAD, sensitivity of this index was 91% (100% in Group II and 75% in Group I). This sensitivity in Group I was identical with that of exercise stress MGBPI. Specificity of SdV/dt/V (86%) was a little inferior to that of exercise stress MGBPI (93%), but it was not statistically significant. In conclusion, SdV/dt/V is a useful systolic phase index to detect CAD. (J.P.N.)

  12. Morphological and Functional Measurements of the Heart Obtained by Magnetic Resonance Imaging in Brazilians

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Robson, E-mail: robmacedo@yahoo.com [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil); Fernandes, Juliano Lara [Universidade Estadual de Campinas, Campinas, SP (Brazil); Andrade, Solange Souza; Rochitte, Carlos Eduardo [Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Lima, Kênio Costa; Maciel, Álvaro Campos Cavalcanti [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil); Maciel, Fernanda Cunha; Alves, Geraldo Souza Pinho [Universidade Potiguar, Natal, RN (Brazil); Coelho, Otávio Rizzi [Universidade Estadual de Campinas, Campinas, SP (Brazil); Diniz, Rosiane Viana Zuza [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil)

    2013-07-15

    Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter =4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age.

  13. Morphological and Functional Measurements of the Heart Obtained by Magnetic Resonance Imaging in Brazilians

    International Nuclear Information System (INIS)

    Macedo, Robson; Fernandes, Juliano Lara; Andrade, Solange Souza; Rochitte, Carlos Eduardo; Lima, Kênio Costa; Maciel, Álvaro Campos Cavalcanti; Maciel, Fernanda Cunha; Alves, Geraldo Souza Pinho; Coelho, Otávio Rizzi; Diniz, Rosiane Viana Zuza

    2013-01-01

    Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter =4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age

  14. Synergistic Utility of Brain Natriuretic Peptide and Left Ventricular Global Longitudinal Strain in Asymptomatic Patients With Significant Primary Mitral Regurgitation and Preserved Systolic Function Undergoing Mitral Valve Surgery.

    Science.gov (United States)

    Alashi, Alaa; Mentias, Amgad; Patel, Krishna; Gillinov, A Marc; Sabik, Joseph F; Popović, Zoran B; Mihaljevic, Tomislav; Suri, Rakesh M; Rodriguez, L Leonardo; Svensson, Lars G; Griffin, Brian P; Desai, Milind Y

    2016-07-01

    In asymptomatic patients with ≥3+ mitral regurgitation and preserved left ventricular (LV) ejection fraction who underwent mitral valve surgery, we sought to discover whether baseline LV global longitudinal strain (LV-GLS) and brain natriuretic peptide provided incremental prognostic utility. Four hundred and forty-eight asymptomatic patients (61±12 years and 69% men) with ≥3+ primary mitral regurgitation and preserved left ventricular ejection fraction, who underwent mitral valve surgery (92% repair) at our center between 2005 and 2008, were studied. Baseline clinical and echocardiographic data (including LV-GLS using Velocity Vector Imaging, Siemens, PA) were recorded. The Society of Thoracic Surgeons score was calculated. The primary outcome was death. Mean Society of Thoracic Surgeons score, left ventricular ejection fraction, mitral effective regurgitant orifice, indexed LV end-diastolic volume, and right ventricular systolic pressure were 4±1%, 62±3%, 0.55±0.2 cm(2), 58±13 cc/m(2), and 37±15 mm Hg, respectively. Forty-five percent of patients had flail. Median log-transformed BNP and LV-GLS were 4.04 (absolute brain natriuretic peptide: 60 pg/dL) and -20.7%. At 7.7±2 years, death occurred in 41 patients (9%; 0% at 30 days). On Cox analysis, a higher Society of Thoracic Surgeons score (hazard ratio 1.55), higher baseline right ventricular systolic pressure (hazard ratio 1.11), more abnormal LV-GLS (hazard ratio 1.17), and higher median log-transformed BNP (hazard ratio 2.26) were associated with worse longer-term survival (all Pright ventricular systolic pressure) provided incremental prognostic utility (χ(2) for longer-term mortality increased from 31-47 to 61; Pleft ventricular ejection fraction who underwent mitral valve surgery, brain natriuretic peptide and LV-GLS provided synergistic risk stratification, independent of established factors. © 2016 American Heart Association, Inc.

  15. Simultaneous pressure-volume measurements using optical sensors and MRI for left ventricle function assessment during animal experiment.

    Science.gov (United States)

    Abi-Abdallah Rodriguez, Dima; Durand, Emmanuel; de Rochefort, Ludovic; Boudjemline, Younes; Mousseaux, Elie

    2015-01-01

    Simultaneous pressure and volume measurements enable the extraction of valuable parameters for left ventricle function assessment. Cardiac MR has proven to be the most accurate method for volume estimation. Nonetheless, measuring pressure simultaneously during MRI acquisitions remains a challenge given the magnetic nature of the widely used pressure transducers. In this study we show the feasibility of simultaneous in vivo pressure-volume acquisitions with MRI using optical pressure sensors. Pressure-volume loops were calculated while inducing three inotropic states in a sheep and functional indices were extracted, using single beat loops, to characterize systolic and diastolic performance. Functional indices evolved as expected in response to positive inotropic stimuli. The end-systolic elastance, representing the contractility index, the diastolic myocardium compliance, and the cardiac work efficiency all increased when inducing inotropic state enhancement. The association of MRI and optical pressure sensors within the left ventricle successfully enabled pressure-volume loop analysis after having respective data simultaneously recorded during the experimentation without the need to move the animal between each inotropic state. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Impairment of left ventricular function during coronary angioplastic occlusion evaluated with a nonimaging scintillation probe.

    Science.gov (United States)

    Hartmann, A; Maul, F D; Zimny, M; Klepzig, H; Vallbracht, C; Kneissl, H G; Schräder, R; Hör, G; Kaltenbach, M

    1991-09-01

    Impairment of left ventricular function during controlled myocardial ischemia induced by coronary angioplasty has been reported from angiographic and echocardiographic studies. Ejection fraction, peak ejection, peak filling rates, and end-systolic and end-diastolic volumes were investigated before, during and after coronary occlusion on-line with a nonimaging scintillation probe. The study consisted of 18 patients (mean age 59 +/- 10 years) with coronary artery stenosis of greater than 70%. During balloon inflation of 60 seconds' duration, coronary occlusion pressure was 31.6 +/- 12 mm Hg. There was no significant change in heart rate. Delay between first and second dilatation was 109 +/- 63 seconds. Ejection fraction decreased from 53 +/- 16 to 40 +/- 12% (first dilatation, p less than 0.01) and to 39 +/- 14% (second dilatation, p less than 0.01) and recovered to 51 +/- 16% 5 minutes after the second dilatation. Peak ejection rate was significantly reduced during the first and second balloon inflations. Peak filling rate decreased from 2.5 +/- 0.8 to 2.0 +/- 0.7 end-diastolic volume.s-1 (first dilatation, p less than 0.01) and to 1.8 +/- 0.7 end-diastolic volume.s-1 (second dilatation, p less than 0.01) and remained reduced at 2.2 +/- 0.7 end-diastolic volume.s-1 (p = not significant) at 5 minutes after the second dilatation. End-systolic and end-diastolic volumes increased significantly during the first and second dilatations and returned to normal after dilatation. It is concluded that short, controlled myocardial ischemia during coronary angioplasty leads to a decrease in systolic and diastolic left ventricular function. Sequential dilatations do not further decrease function if a sufficient interval is kept.

  17. Evaluation of the influence of change in heart rate on left ventricular diastolic function indices

    International Nuclear Information System (INIS)

    Kimura, Motomasa; Yamagishi, Hiroaki; Seino, Yasuyuki; Odano, Ikuo; Sakai, Kunio; Yamamoto, Tomohiko; Tsuda, Takashi

    1988-01-01

    In order to assess the influence of change in heart rate on left ventricular diastolic function indices, ECG gated cardiac pool study was performed in 6 patients with implanted programmable AAI pacemakers. Heart rate was changed by atrial pacing from 50 to 120 beats/min, every 10 beats/min. The filling fraction during first third of diastole (1/3FF), the peak filling rate (PFR), mean first third filling rate (1/3FR-mean) and early filling volume ratio (%EFV), being used as the indices of left ventricular diastolic performance, were assessed. In accordance with increase in heart rate, 1/3FF decreased significantly. PFR were fairly stable from 50 to 80 beats/min, but increased significantly from 90 to 120 beats/min. 1/3FR-mean and %EFV did not change significantly, but 1/3FR-mean showed decreasing tendency and %EFV showed increasing tendency as the heart rate was increased. %EFV was more changeable index than other indices among clinical cases. These results indicate that PFR and 1/3FR-mean were appropriate diastolic phase indices at rest. (author)

  18. Usefulness of {sup 201}Tl myocardial perfusion SPECT in prediction of left ventricular remodeling following an acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seok Nam; Park, C. H.; Hwang, Kyung Hoon [Ajou Univ. College of Medicine, Suwon (Korea, Republic of)

    2000-02-01

    We investigated the role of myocardial perfusion SPECT in prediction of ventricular dilatation and the role of revascularization including thrombolytic therapy and PTCA in prevention of ventricular dilatation after an acute myocardial linfarction (AMI). We performed dipyridamole stress, 4 hour redistribution, and 24 hour reinjection Tl-201 SPECT in 6 patients with AMI two to nine days after attack. Perfusion and wall motion abnormalities were quantified by perfusion index(PI) and wall motion index (WMI). Left ventricular ejection fraction (LVEF), WMI and ventricular volume were measured within 1 week of AMI and after average of 6 months. According to serial changes of left ventricular end-diastolic volume (LVEDV), patients were divided into two groups. We compared WMI, PI and LVEF between the two groups. Relationships among degree of volume, stress-rest PI, WMI, CKMB,Q wave, LVEF and revascularization were analysed using multivariate analysis. Only initial rest perfusion index was significantly different between the two groups (p<0.05). While initial LVEF, stress PI, CKMB, trial of revascularization procedure, presence of Q wave and WMI were not significantly different between the two groups. Eight of 16 patients (50%) showed LV dilatation on follow-up echocardiography. Three of 3 patients (100%) who did not undergo revascualrization procedure documented LV dilatation. And only 5 (38%) of the remaining 13 patients who underwent revascularization revealed LV dilatation. There was no difference in infarct location between the two groups. By multivariate linear regression analysis in patients only undergoing revascularization, rest perfusion index was the only significant factor. Myocardial perfusion SPECT performed prior to revascularization was useful in prediction of LV dilatation after an AMI. Rest perfusion index on myocardial perfusion plays as a significant predictor of left ventricular dilatation after AMI. And revascularization appears to be a valuable

  19. Relief of mitral leaflet tethering following chronic myocardial infarction by chordal cutting diminishes left ventricular remodeling.

    Science.gov (United States)

    Messas, Emmanuel; Bel, Alain; Szymanski, Catherine; Cohen, Iris; Touchot, Bernard; Handschumacher, Mark D; Desnos, Michel; Carpentier, Alain; Menasché, Philippe; Hagège, Albert A; Levine, Robert A

    2010-11-01

    one of the key targets in treating mitral regurgitation (MR) is reducing the otherwise progressive left ventricular (LV) remodeling that exacerbates MR and conveys adverse prognosis. We have previously demonstrated that severing 2 second-order chordae to the anterior mitral leaflet relieves tethering and ischemic MR acutely. The purpose of this study was to test whether this technique reduces the progression of LV remodeling in the chronic ischemic MR setting. a posterolateral MI was created in 18 sheep by obtuse marginal branch ligation. After chronic remodeling and MR development at 3 months, 6 sheep were randomized to sham surgery (control group) and 12 to second-order chordal cutting (6 each to anterior leaflet [AntL] and bileaflet [BiL] chordal cutting, techniques that are in clinical application). At baseline, chronic infarction (3 months), and follow-up at a mean of 6.6 months post-myocardial infarction (MI) (euthanasia), we measured LV end-diastolic (EDV) and end-systolic volume (ESV), ejection fraction, wall motion score index, and posterior leaflet (PL) restriction angle relative to the annulus by 2D and 3D echocardiography. All measurements were comparable among groups at baseline and chronic MI. At euthanasia, AntL and BiL chordal cutting limited the progressive remodeling seen in controls. LVESV increased relative to chronic MI by 109±8.7% in controls versus 30.5±6.1% with chordal cutting (Pbenefits have the potential to improve clinical outcomes.

  20. Comparative study of diastolic filling under varying left ventricular wall stiffness

    Science.gov (United States)

    Mekala, Pritam; Santhanakrishnan, Arvind

    2014-11-01

    Pathological remodeling of the human cardiac left ventricle (LV) is observed in hypertensive heart failure as a result of pressure overload. Myocardial stiffening occurs in these patients prior to chronic maladaptive changes, resulting in increased LV wall stiffness. The goal of this study was to investigate the change in intraventricular filling fluid dynamics inside a physical model of the LV as a function of wall stiffness. Three LV models of varying wall stiffness were incorporated into an in vitro flow circuit driven by a programmable piston pump. Windkessel elements were used to tune the inflow and systemic pressure in the model with least stiffness to match healthy conditions. Models with stiffer walls were comparatively tested maintaining circuit compliance, resistance and pump amplitude constant. 2D phase-locked PIV measurements along the central plane showed that with increase in wall stiffness, the peak velocity and cardiac output inside the LV decreased. Further, inflow vortex ring propagation toward the LV apex was reduced with increasing stiffness. The above findings indicate the importance of considering LV wall relaxation characteristics in pathological studies of filling fluid dynamics.

  1. Acute Effects of Hemodialysis on Left and Right Ventricular Function: A Doppler Tissue Imaging Study

    Directory of Open Access Journals (Sweden)

    Tansel Erol

    2012-08-01

    Full Text Available Purpose: Doppler tissue imaging (DTI allows noninvasive assessment of both left ventricular (LV and right ventricular (RV function. The aim of this study was to evaluate the effect of hemodialysis (HD on LV and RV function using DTI. Method: Our study group included 30 patients on chronic HD program (mean age 45 15 years. Myocardial (Sm, Em, Am and annular velocities (Ea, Aa were measured in several cardiac territories before and after HD. Results: After HD, Ea significantly reduced from 10.8 3.4 cm/s to 9.6 2.4 cm/s (p = 0.029. Patients exhibited a lower Em following HD in all measured territories. Em/Am ratio was also reduced for each LV wall investigated after HD in all measured territories. At the RV segments, Sm, Em, and Am decreased significantly in all measured territories. Em of the anterior wall was positively related to ultrafiltration volume (r = 0.25, p = 0.006, whereas the decrease of Sm of RV basal segment correlated with a decrease of diastolic blood pressure (r = 0.23, p < 0.01. Conclusion: Our data indicate that a single HD session is associated with acute changes of systolic and diastolic parameters of LV and RV. [Cukurova Med J 2012; 37(4.000: 215-222

  2. Enhancing ejection fraction measurement through 4D respiratory motion compensation in cardiac PET imaging

    Science.gov (United States)

    Tang, Jing; Wang, Xinhui; Gao, Xiangzhen; Segars, W. Paul; Lodge, Martin A.; Rahmim, Arman

    2017-06-01

    ECG gated cardiac PET imaging measures functional parameters such as left ventricle (LV) ejection fraction (EF), providing diagnostic and prognostic information for management of patients with coronary artery disease (CAD). Respiratory motion degrades spatial resolution and affects the accuracy in measuring the LV volumes for EF calculation. The goal of this study is to systematically investigate the effect of respiratory motion correction on the estimation of end-diastolic volume (EDV), end-systolic volume (ESV), and EF, especially on the separation of normal and abnormal EFs. We developed a respiratory motion incorporated 4D PET image reconstruction technique which uses all gated-frame data to acquire a motion-suppressed image. Using the standard XCAT phantom and two individual-specific volunteer XCAT phantoms, we simulated dual-gated myocardial perfusion imaging data for normally and abnormally beating hearts. With and without respiratory motion correction, we measured the EDV, ESV, and EF from the cardiac-gated reconstructed images. For all the phantoms, the estimated volumes increased and the biases significantly reduced with motion correction compared with those without. Furthermore, the improvement of ESV measurement in the abnormally beating heart led to better separation of normal and abnormal EFs. The simulation study demonstrated the significant effect of respiratory motion correction on cardiac imaging data with motion amplitude as small as 0.7 cm. The larger the motion amplitude the more improvement respiratory motion correction brought about on the EF measurement. Using data-driven respiratory gating, we also demonstrated the effect of respiratory motion correction on estimating the above functional parameters from list mode patient data. Respiratory motion correction has been shown to improve the accuracy of EF measurement in clinical cardiac PET imaging.

  3. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  4. Integration of SPICE with TEK LV500 ASIC Design Verification System

    Directory of Open Access Journals (Sweden)

    A. Srivastava

    1996-01-01

    Full Text Available The present work involves integration of the simulation stage of design of a VLSI circuit and its testing stage. The SPICE simulator, TEK LV500 ASIC Design Verification System, and TekWaves, a test program generator for LV500, were integrated. A software interface in ‘C’ language in UNIX ‘solaris 1.x’ environment has been developed between SPICE and the testing tools (TekWAVES and LV500. The function of the software interface developed is multifold. It takes input from either SPICE2G.6 or SPICE 3e.1. The output generated by the interface software can be given as an input to either TekWAVES or LV500. A graphical user interface has also been developed with OPENWlNDOWS using Xview tool kit on SUN workstation. As an example, a two phase clock generator circuit has been considered and usefulness of the software demonstrated. The interface software could be easily linked with VLSI design such as MAGIC layout editor.

  5. Radionuclide analysis of right and left ventricular response to exercise in patients with atrial and ventricular septal defects

    International Nuclear Information System (INIS)

    Peter, C.A.; Bowyer, K.; Jones, R.H.

    1983-01-01

    In patients with ventricular or atrial septal defect, the ventricle which is chronically volume overloaded might not appropriately respond to increased demand for an augmentation in output and thereby might limit total cardiac function. In this study we simultaneously measured right and left ventricular response to exercise in 10 normal individuals, 10 patients with ventricular septal defect (VSD), and 10 patients with atrial septal defect (ASD). The normal subjects increased both right and left ventricular ejection fraction, end-diastolic volume, and stroke volume to achieve a higher cardiac output during exercise. Patients with VSD failed to increase right ventricular ejection fraction, but increased right ventricular end-diastolic volume and stroke volume. Left ventricular end-diastolic volume did not increase in these patients but ejection fraction, stroke volume, and forward left ventricular output achieved during exercise were comparable to the response observed in healthy subjects. In the patients with ASD, no rest-to-exercise change occurred in either right ventricular ejection fraction, end-diastolic volume, or stroke volume. In addition, left ventricular end-diastolic volume failed to increase, and despite an increase in ejection fraction, left ventricular stroke volume remained unchanged from rest to exercise. Therefore, cardiac output was augmented only by the heart rate increase in these patients. Right ventricular function appeared to be the major determinant of total cardiac output during exercise in patients with cardiac septal defects and left-to-right shunt

  6. Total average diastolic longitudinal displacement by colour tissue doppler imaging as an assessment of diastolic function

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sørensen, Tor; Søgaard, Peter

    2016-01-01

    BACKGROUND: The current method for a non-invasive assessment of diastolic dysfunction is complex with the use of algorithms of many different echocardiographic parameters. Total average diastolic longitudinal displacement (LD), determined by colour tissue Doppler imaging (TDI) via the measurement...

  7. La piattaforma POS/LV di Applanix nelle applicazioni di laser scanner cinematico

    OpenAIRE

    Domenico Santarsiero

    2008-01-01

    The Applanix POS/LV platform in cinematic laser scanner applicationsOn the 11th of march the GEOmedia editorial unit had the pleasure of hosting a technical meeting dedicated to the Applanix LANDMark new Position and Orientation System for Land Vehicles (POS/LV)field test. The meeting, which is part of an italian tour organized by Louis Nastro (Applanix Director of Land Products) and Terenzio Mariani (Sales manager for Italy), helped to test the functionalities of a complete POS/LV system equ...

  8. Radionuclide angiographic evaluation of left ventricular performance at rest and during exercise in patients with aortic regurgitation

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Heo, J.

    1986-01-01

    Radionuclide angiographic evaluation of LV performance at rest and during exercise in patients with AR have shown that an abnormal EF response to exercise may be observed in asymptomatic patients with normal resting LV function. The EF response to exercise has been correlated with a number of clinical and exercise measurements; important among these are the slope of the systolic pressure-to-end-systolic volume, end-systolic volume, cardiac index, pulmonary capillary wedge pressure, and wall stress. The changes in the regurgitant fraction, EF, and LV volume have shown considerable individual variability; they have also allowed a better understanding of the circulatory responses during exercise. Radionuclide angiography provides a reliable and reproducible method of measuring the rest LVEF that is important in the timing and the outcome of valve replacement. The value of the EF response to exercise in patient management is not yet clear; it is possible that other radionuclide-derived measurements at rest or during exercise, such as the systolic pressure-to-end-systolic volume relationship, and the end-systolic volume may provide complementary information to that provided by the EF

  9. Evaluation of the cardiac efficiency by means of functional radiocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    A new method of evaluating the cardiac efficiency by means of radiocardiography performed on exertion with /sup 113m/InCl is reported. Analysis of stroke volume, end diastolic volume and of the quotient of cardiac output to end diastolic volume on exertion enables an adequate evaluation of the actual myocardial efficiency.

  10. Hemodynamic and radionuclide effects of acute captopril therapy for heart failure: changes in left and right ventricular volumes and function at rest and during exercise

    International Nuclear Information System (INIS)

    Massie, B.; Kramer, B.L.; Topic, N.; Henderson, S.G.

    1982-01-01

    Although the resting hemodynamic effects of captopril in congestive heart failure are known, little information is available about the hemodynamic response to captopril during exercise or about changes in noninvasive measurements of the size and function of both ventricles. In this study, 14 stable New York Heart Association class III patients were given 25 mg of oral captopril. Rest and exercise hemodynamic measurements and blood pool scintigrams were performed simultaneously before and 90 minutes after captopril. The radionuclide studies were analyzed for left and right ventricular end-diastolic volumes, end-systolic volumes, ejection fractions and pulmonary blood volume. The primary beneficial responses at rest were decreases in left and right ventricular end-diastolic volumes from 388 +/- 81 to 350 +/- 77 ml and from 52 +/- 26 to 43 +/- 20 volume units, respectively, and in their corresponding filling pressures, from 24 +/- 10 to 17 +/- 9 mm Hg and 10 +/- 5 to 6 +/- 5 mm Hg. Although stroke volume did not increase significantly, both left and right ventricular ejection fractions increased slightly, from 19 +/- 6% to 22+/- 5% and from 25 +/- 9% to 29 +/- 11%, respectively. During exercise, similar changes were noted in both hemodynamic and radionuclide indexes. This, in patients with moderate symptomatic limitation from chronic heart failure, captopril predominantly reduces ventricular volume and filling pressure, with a less significant effect on cardiac output. These effects persist during exercise, when systemic vascular resistance is already very low. Radionuclide techniques are valuable in assessing the drug effect in these subjects, particularly when ventricular volumes are also measured

  11. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Bak, So Hyeon; Jeon, Hae Jeong (Dept. of Radiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)); Ko, Sung Min (Dept. of Radiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of); Research Inst. of Medical Science, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)), Email: 20070437@kuh.ac.kr; Yang, Hyun Suk; Hwang, Hweung Kon (Dept. of Cardiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)); Song, Meong Gun (Dept. of Thoracic Surgery, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of))

    2012-04-15

    Background: Left ventricular (LV) function is a vital parameter for prognosis, therapy guidance, and follow-up of cardiovascular disease. Dual-source computed tomography (DSCT) provides an accurate analysis of global LV function. Purpose: To assess the performance of DSCT in the determination of global LV functional parameters in comparison with cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) in patients with valvular heart disease (VHD). Material and Methods: A total of 111 patients (58 men, mean age 49.9 years) with known VHD and who underwent DSCT, 2D-TTE, and CMR a period of 2 weeks before undergoing valve surgery were included in this study. LV end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were calculated by DSCT using the threshold-based technique, by 2D-TTE using a modified Simpson's method, and by CMR using Simpson's method. Agreement for parameters of LV global function was determined with the Pearson's correlation coefficient (r) and Bland-Altman analysis. All the DSCT and CMR data-sets were assessed independently by two readers. Results: Fifty of the total 111 patients had aortic VHD, 29 patients had mitral VHD, and 32 patients had mixed aortic and mitral VHD. An excellent inter-observer agreement was seen for the assessment of global LV function using DSCT (r 0.910-0.983) and CMR (r = 0.854-0.965). An excellent or good correlation (r 0.93, 0.95, 0.87, and 0.71, respectively, P < 0.001) was noted between the DSCT and 2D-TTE values for EDV, ESV, SV, and EF. EDV (33.7 mL, P < 0.001), ESV (12.1 mL, P < 0.001), SV (21.2 mL, P < 0.001), and EF (1.6%, P = 0.019) were significantly overestimated by DSCT when compared with 2D-TTE. An excellent correlation (r = 0.96, 0.97, 0.91, and 0.94, respectively, P < 0.001) between DSCT and CMR was seen in the evaluation of EDV, ESV, SV, and EF. EDV (15.9 mL, P < 0.001), ESV (7.3 mL, P < 0.001), and SV

  12. Early myocardial dysfunction in streptozotocin-induced diabetic mice: a study using in vivo magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Chandrasekaran Suresh

    2007-02-01

    Full Text Available Abstract Background Diabetes is associated with a cardiomyopathy that is independent of coronary artery disease or hypertension. In the present study we used in vivo magnetic resonance imaging (MRI and echocardiographic techniques to examine and characterize early changes in myocardial function in a mouse model of type 1 diabetes. Methods Diabetes was induced in 8-week old C57BL/6 mice with two intraperitoneal injections of streptozotocin. The blood glucose levels were maintained at 19–25 mmol/l using intermittent low dosages of long acting insulin glargine. MRI and echocardiography were performed at 4 weeks of diabetes (age of 12 weeks in diabetic mice and age-matched controls. Results After 4 weeks of hyperglycemia one marker of mitochondrial function, NADH oxidase activity, was decreased to 50% of control animals. MRI studies of diabetic mice at 4 weeks demonstrated significant deficits in myocardial morphology and functionality including: a decreased left ventricular (LV wall thickness, an increased LV end-systolic diameter and volume, a diminished LV ejection fraction and cardiac output, a decreased LV circumferential shortening, and decreased LV peak ejection and filling rates. M-mode echocardiographic and Doppler flow studies of diabetic mice at 4 weeks showed a decreased wall thickening and increased E/A ratio, supporting both systolic and diastolic dysfunction. Conclusion Our study demonstrates that MRI interrogation can identify the onset of diabetic cardiomyopathy in mice with its impaired functional capacity and altered morphology. The MRI technique will lend itself to repetitive study of early changes in cardiac function in small animal models of diabetic cardiomyopathy.

  13. Early myocardial dysfunction in streptozotocin-induced diabetic mice: a study using in vivo magnetic resonance imaging (MRI)

    Science.gov (United States)

    Yu, Xichun; Tesiram, Yasvir A; Towner, Rheal A; Abbott, Andrew; Patterson, Eugene; Huang, Shijun; Garrett, Marion W; Chandrasekaran, Suresh; Matsuzaki, Satoshi; Szweda, Luke I; Gordon, Brian E; Kem, David C

    2007-01-01

    Background Diabetes is associated with a cardiomyopathy that is independent of coronary artery disease or hypertension. In the present study we used in vivo magnetic resonance imaging (MRI) and echocardiographic techniques to examine and characterize early changes in myocardial function in a mouse model of type 1 diabetes. Methods Diabetes was induced in 8-week old C57BL/6 mice with two intraperitoneal injections of streptozotocin. The blood glucose levels were maintained at 19–25 mmol/l using intermittent low dosages of long acting insulin glargine. MRI and echocardiography were performed at 4 weeks of diabetes (age of 12 weeks) in diabetic mice and age-matched controls. Results After 4 weeks of hyperglycemia one marker of mitochondrial function, NADH oxidase activity, was decreased to 50% of control animals. MRI studies of diabetic mice at 4 weeks demonstrated significant deficits in myocardial morphology and functionality including: a decreased left ventricular (LV) wall thickness, an increased LV end-systolic diameter and volume, a diminished LV ejection fraction and cardiac output, a decreased LV circumferential shortening, and decreased LV peak ejection and filling rates. M-mode echocardiographic and Doppler flow studies of diabetic mice at 4 weeks showed a decreased wall thickening and increased E/A ratio, supporting both systolic and diastolic dysfunction. Conclusion Our study demonstrates that MRI interrogation can identify the onset of diabetic cardiomyopathy in mice with its impaired functional capacity and altered morphology. The MRI technique will lend itself to repetitive study of early changes in cardiac function in small animal models of diabetic cardiomyopathy. PMID:17309798

  14. Assessment of vasodilator therapy in patients with severe congestive heart failure: limitations of measurements of left ventricular ejection fraction and volumes

    International Nuclear Information System (INIS)

    Firth, B.G.; Dehmer, G.J.; Markham, R.V. Jr.; Willerson, J.T.; Hillis, L.D.

    1982-01-01

    Although noninvasive techniques are often used to assess the effect of vasodilator therapy in patients with congestive heart failure, it is unknown whether changes in noninvasively determined left ventricular ejection fraction, volume, or dimension reliably reflect alterations in intracardiac pressure and flow. Accordingly, we compared the acute effect of sodium nitroprusside on left ventricular volume and ejection fraction (determined scintigraphically) with its effect on intracardiac pressure and forward cardiac index (determined by thermodilution) in 12 patients with severe, chronic congestive heart failure and a markedly dilated left ventricle. Nitroprusside (infused at 1.3 +/- 1.1 [mean +/- standard deviation] microgram/kg/min) caused a decrease in mean systemic arterial, mean pulmonary arterial, and mean pulmonary capillary wedge pressure as well as a concomitant increase in forward cardiac index. Simultaneously, left ventricular end-diastolic and end-systolic volume indexes decreased, but the scintigraphically determined cardiac index did not change significantly. Left ventricular ejection fraction averaged 0.19 +/- 0.05 before nitroprusside administration and increased by less than 0.05 units in response to nitroprusside in 11 of 12 patients. The only significant correlation between scintigraphically and invasively determined variables was that between the percent change in end-diastolic volume index and the percent change in pulmonary capillary wedge pressure (r . 0.68, p . 0.01). Although nitroprusside produced changes in scintigraphically determined left ventricular ejection fraction, end-systolic volume index, and cardiac index, these alterations bore no predictable relation to changes in intracardiac pressure, forward cardiac index, or vascular resistance. Furthermore, nitroprusside produced a considerably greater percent change in the invasively measured variables than in the scintigraphically determined ones

  15. Application of a simplified definition of diastolic function in severe sepsis and septic shock.

    Science.gov (United States)

    Lanspa, Michael J; Gutsche, Andrea R; Wilson, Emily L; Olsen, Troy D; Hirshberg, Eliotte L; Knox, Daniel B; Brown, Samuel M; Grissom, Colin K

    2016-08-04

    Left ventricular diastolic dysfunction is common in patients with severe sepsis or septic shock, but the best approach to categorization is unknown. We assessed the association of common measures of diastolic function with clinical outcomes and tested the utility of a simplified definition of diastolic dysfunction against the American Society of Echocardiography (ASE) 2009 definition. In this prospective observational study, patients with severe sepsis or septic shock underwent transthoracic echocardiography within 24 h of onset of sepsis (median 4.3 h). We measured echocardiographic parameters of diastolic function and used random forest analysis to assess their association with clinical outcomes (28-day mortality and ICU-free days to day 28) and thereby suggest a simplified definition. We then compared patients categorized by the ASE 2009 definition and our simplified definition. We studied 167 patients. The ASE 2009 definition categorized only 35 % of patients. Random forest analysis demonstrated that the left atrial volume index and deceleration time, central to the ASE 2009 definition, were not associated with clinical outcomes. Our simplified definition used only e' and E/e', omitting the other measurements. The simplified definition categorized 87 % of patients. Patients categorized by either ASE 2009 or our novel definition had similar clinical outcomes. In both definitions, worsened diastolic function was associated with increased prevalence of ischemic heart disease, diabetes, and hypertension. A novel, simplified definition of diastolic dysfunction categorized more patients with sepsis than ASE 2009 definition. Patients categorized according to the simplified definition did not differ from patients categorized according to the ASE 2009 definition in respect to clinical outcome or comorbidities.

  16. TO STUDY AND EVALUATE DIASTOLIC DYSFUNCTION IN PATIENTS OF ALCOHOLIC AND NON-ALCOHOLIC CIRRHOSIS

    Directory of Open Access Journals (Sweden)

    Gaurav Sudhir

    2016-04-01

    Full Text Available BACKGROUND Cardiovascular dysfunction is the major component of morbidity in patients of liver cirrhosis and a cardinal prognostic indicator in patients undergoing liver transplantation. The constellation of hyperdynamic circulation, peripheral vasodilation and volume overload alters the systolic and diastolic dysfunction leading to cirrhotic cardiomyopathy (CCM. In this study, we evaluated and compared the diastolic dysfunction among alcoholic and non-alcoholic cirrhotic patients. AIMS 1 To Study the Prevalence of Diastolic Dysfunction in Alcoholic & Non-Alcoholic Cirrhotics and Controls. 2 To Compare the Diastolic functional status between alcoholic and non-alcoholic cirrhosis patients. MATERIALS AND METHODS A cross-sectional case control study was conducted in 100 male cirrhotic patients consisting of alcoholic and non-alcoholic cirrhotic subjects with age matched 50 controls in Pt. JNM Medical College & Dr. BRAM Hospital, Raipur. Left ventricular diastolic dysfunction was assessed using echocardiographic parameters. STATISTICAL ANALYSIS The range, median, standard deviation and statistical significance were calculated. Most of the data is analysed by Student Ttest, Mann Whitney U test, while the data with frequency distribution is analysed by Fisher’s exact. With p value 1. CONCLUSION Our study showed that patients with alcoholic and non-alcoholic cirrhosis have higher occurrence of DD (49% and 46% respectively than controls owing to alterations in the myocardial contractile and relaxation function. It also shows that although DD is a frequent event in cirrhosis, it is usually of mild degree and does not correlate with severity of liver dysfunction. There were no significant differences in diastolic parameters between alcoholic and non-alcoholic cirrhosis concluding that alcohol likely plays a non-significant role in cardiovascular dysfunction in cirrhotics.

  17. Increased infarct wall thickness by a bio-inert material is insufficient to prevent negative left ventricular remodeling after myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Aboli A Rane

    Full Text Available Several injectable materials have been shown to preserve or improve cardiac function as well as prevent or slow left ventricular (LV remodeling post-myocardial infarction (MI. However, it is unclear as to whether it is the structural support or the bioactivity of these polymers that lead to beneficial effects. Herein, we examine how passive structural enhancement of the LV wall by an increase in wall thickness affects cardiac function post-MI using a bio-inert, non-degradable synthetic polymer in an effort to better understand the mechanisms by which injectable materials affect LV remodeling.Poly(ethylene glycol (PEG gels of storage modulus G' = 0.5±0.1 kPa were injected and polymerized in situ one week after total occlusion of the left coronary artery in female Sprague Dawley rats. The animals were imaged using magnetic resonance imaging (MRI at 7±1 day(s post-MI as a baseline and again post-injection 49±4 days after MI. Infarct wall thickness was statistically increased in PEG gel injected vs. control animals (p<0.01. However, animals in the polymer and control groups showed decreases in cardiac function in terms of end diastolic volume, end systolic volume and ejection fraction compared to baseline (p<0.01. The cellular response to injection was also similar in both groups.The results of this study demonstrate that passive structural reinforcement alone was insufficient to prevent post-MI remodeling, suggesting that bioactivity and/or cell infiltration due to degradation of injectable materials are likely playing a key role in the preservation of cardiac function, thus providing a deeper understanding of the influencing properties of biomaterials necessary to prevent post-MI negative remodeling.

  18. Real-time cardiac magnetic resonance cine imaging with sparse sampling and iterative reconstruction for left-ventricular measures: Comparison with gold-standard segmented steady-state free precession.

    Science.gov (United States)

    Camargo, Gabriel C; Erthal, Fernanda; Sabioni, Leticia; Penna, Filipe; Strecker, Ralph; Schmidt, Michaela; Zenge, Michael O; Lima, Ronaldo de S L; Gottlieb, Ilan

    2017-05-01

    Segmented cine imaging with a steady-state free-precession sequence (Cine-SSFP) is currently the gold standard technique for measuring ventricular volumes and mass, but due to multi breath-hold (BH) requirements, it is prone to misalignment of consecutive slices, time consuming and dependent on respiratory capacity. Real-time cine avoids those limitations, but poor spatial and temporal resolution of conventional sequences has prevented its routine application. We sought to examine the accuracy and feasibility of a newly developed real-time sequence with aggressive under-sampling of k-space using sparse sampling and iterative reconstruction (Cine-RT). Stacks of short-axis cines were acquired covering both ventricles in a 1.5T system using gold standard Cine-SSFP and Cine-RT. Acquisition parameters for Cine-SSFP were: acquisition matrix of 224×196, temporal resolution of 39ms, retrospective gating, with an average of 8 heartbeats per slice and 1-2 slices/BH. For Cine-RT: acquisition matrix of 224×196, sparse sampling net acceleration factor of 11.3, temporal resolution of 41ms, prospective gating, real-time acquisition of 1 heart-beat/slice and all slices in one BH. LV contours were drawn at end diastole and systole to derive LV volumes and mass. Forty-one consecutive patients (15 male; 41±17years) in sinus rhythm were successfully included. All images from Cine-SSFP and Cine-RT were considered to have excellent quality. Cine-RT-derived LV volumes and mass were slightly underestimated but strongly correlated with gold standard Cine-SSFP. Inter- and intra-observer analysis presented similar results between both sequences. Cine-RT featuring sparse sampling and iterative reconstruction can achieve spatial and temporal resolution equivalent to Cine-SSFP, providing excellent image quality, with similar precision measurements and highly correlated and only slightly underestimated volume and mass values. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Cardiac impairment evaluated by transesophageal echocardiography and invasive measurements in rats undergoing sinoaortic denervation.

    Directory of Open Access Journals (Sweden)

    Raquel A Sirvente

    Full Text Available BACKGROUND: Sympathetic hyperactivity may be related to left ventricular (LV dysfunction and baro- and chemoreflex impairment in hypertension. However, cardiac function, regarding the association of hypertension and baroreflex dysfunction, has not been previously evaluated by transesophageal echocardiography (TEE using intracardiac echocardiographic catheter. METHODS AND RESULTS: We evaluated exercise tests, baroreflex sensitivity and cardiovascular autonomic control, cardiac function, and biventricular invasive pressures in rats 10 weeks after sinoaortic denervation (SAD. The rats (n = 32 were divided into 4 groups: 16 Wistar (W with (n = 8 or without SAD (n = 8 and 16 spontaneously hypertensive rats (SHR with (n = 8 or without SAD (SHRSAD (n = 8. Blood pressure (BP and heart rate (HR did not change between the groups with or without SAD; however, compared to W, SHR groups had higher BP levels and BP variability was increased. Exercise testing showed that SHR had better functional capacity compared to SAD and SHRSAD. Echocardiography showed left ventricular (LV concentric hypertrophy; segmental systolic and diastolic biventricular dysfunction; indirect signals of pulmonary arterial hypertension, mostly evident in SHRSAD. The end-diastolic right ventricular (RV pressure increased in all groups compared to W, and the end-diastolic LV pressure increased in SHR and SHRSAD groups compared to W, and in SHRSAD compared to SAD. CONCLUSIONS: Our results suggest that baroreflex dysfunction impairs cardiac function, and increases pulmonary artery pressure, supporting a role for baroreflex dysfunction in the pathogenesis of hypertensive cardiac disease. Moreover, TEE is a useful and feasible noninvasive technique that allows the assessment of cardiac function, particularly RV indices in this model of cardiac disease.

  20. Formation and characterization of FeLV iscoms.

    NARCIS (Netherlands)

    L. Akerblom; K. Strö mstedt; S. Hö glund; A.D.M.E. Osterhaus (Albert); B. Morein (Bror)

    1989-01-01

    textabstractImmunostimulating complexes (ISCOMs) have been prepared from feline leukaemia virus (FeLV) envelope proteins. The ISCOMs were characterized biochemically in SDS-polyacrylamide gel electrophoresis showing the presence of proteins of estimated molecular weights of 15,000, 27,000 and

  1. Association between lectin complement pathway initiators, C-reactive protein and left ventricular remodeling in myocardial infarction-a magnetic resonance study

    DEFF Research Database (Denmark)

    Schoos, Mikkel Malby; Munthe-Fog, Lea; Skjoedt, Mikkel-Ole

    2013-01-01

    Lectin complement pathway (LP) activation is an important mechanism in myocardial ischemia reperfusion injury (IRI). LP is activated via the recognition molecules mannose-binding lectin (MBL), ficolins-2 and-3 and is regulated by MBL/Ficolin-associated Protein-1 (MAP-1). Also, C-reactive protein...... (CRP) and ficolin-2 interact in vitro, but the role of the ficolins in IRI is unknown.Methods and results In 55 patients with ST segment elevation myocardial infarction, we investigated the association of LP components and CRP in plasma samples with left ventricular (LV) end systolic and diastolic......-activation in IRI and LV remodeling....

  2. Adjustable, physiological ventricular restraint improves left ventricular mechanics and reduces dilatation in an ovine model of chronic heart failure.

    Science.gov (United States)

    Ghanta, Ravi K; Rangaraj, Aravind; Umakanthan, Ramanan; Lee, Lawrence; Laurence, Rita G; Fox, John A; Bolman, R Morton; Cohn, Lawrence H; Chen, Frederick Y

    2007-03-13

    Ventricular restraint is a nontransplantation surgical treatment for heart failure. The effect of varying restraint level on left ventricular (LV) mechanics and remodeling is not known. We hypothesized that restraint level may affect therapy efficacy. We studied the immediate effect of varying restraint levels in an ovine heart failure model. We then studied the long-term effect of restraint applied over a 2-month period. Restraint level was quantified by use of fluid-filled epicardial balloons placed around the ventricles and measurement of balloon luminal pressure at end diastole. At 4 different restraint levels (0, 3, 5, and 8 mm Hg), transmural myocardial pressure (P(tm)) and indices of myocardial oxygen consumption (MVO2) were determined in control (n=5) and ovine heart failure (n=5). Ventricular restraint therapy decreased P(tm) and MVO2, and improved mechanical efficiency. An optimal physiological restraint level of 3 mm Hg was identified to maximize improvement without an adverse affect on systemic hemodynamics. At this optimal level, end-diastolic P(tm) and MVO2 indices decreased by 27% and 20%, respectively. The serial longitudinal effects of optimized ventricular restraint were then evaluated in ovine heart failure with (n=3) and without (n=3) restraint over 2 months. Optimized ventricular restraint prevented and reversed pathological LV dilatation (130+/-22 mL to 91+/-18 mL) and improved LV ejection fraction (27+/-3% to 43+/-5%). Measured restraint level decreased over time as the LV became smaller, and reverse remodeling slowed. Ventricular restraint level affects the degree of decrease in P(tm), the degree of decrease in MVO2, and the rate of LV reverse remodeling. Periodic physiological adjustments of restraint level may be required for optimal restraint therapy efficacy.

  3. Assessment of cardiac morphology and ventricular function in healthy Chinese individuals using MRI

    International Nuclear Information System (INIS)

    Lu Minjie; Zhao Shihua; Jiang Shiliang

    2011-01-01

    Objective: To investigate reproducibility of cardiac MRI for assessment of cardiac morphology and ventricular function in selected normal Chinese Han population. Methods: Two hundred and sixty-nine normal volunteers underwent cardiac MRI using a 1.5 T MR system. HASTE and steady state free precession imaging were performed with long and short axis images and cine mode through the ventricle with wireless vector cardiac gating. The images were reviewed by two independent observers. The dimensions of cardiac chambers and ventricular function including ejection fraction (EF), end diastolic volume (EDV) , end systolic volume (ESV) and myocardial mass were evaluated. The data between male and female were compared by using two-tailed unpaired t test. Results: Total imaging time was (15±3) min. The anteroposterior diameter of the left atrium was (2.87±0.77) cm, the right atrial diameter perpendicular to the atrial septum was (3.61±0.57) cm, the end diastolic diameter of the left ventricle was (4.97± 0.52) cm, the end diastolic diameter of the right ventricle was (2.65±0.48) cm. On the left ventricle, EF was (60.62±7.08)%, EDV was (115.37±26.71) ml, ESV was (46.02±15.72) ml and LV mass was (82.97±24.03) g. On the right ventricle, EF was (47.73±6.50)%, EDV was (128.27±32.16) ml, ESV was (67.7±21.07) ml and RV mass was (48.24±13.42) g. There were no statistically significant differences in LVESV (P=0.144), LVEDV index (P=0.714), LVESV index (P=0.113), LVCI (P=0.199), RVEF (P=0.296) and RV mass (P=0.093), and statistically significant differences in other cardiac parameters between male and female. Conclusion: Cardiac MRI can provide useful information about cardiac function and morphology with a high level of reproducibility in normal Chinese Han population. (authors)

  4. Clinical Characteristics and Outcomes of Patients with Amphetamine-Associated Cardiomyopathy in South Auckland, New Zealand.

    Science.gov (United States)

    Kueh, Shaw-Hua Anthony; Gabriel, Ruvin S; Lund, Mayanna; Sutton, Tim; Bradley, Joshua; Kerr, Andrew J; Looi, Jen-Li

    2016-11-01

    Amphetamine-associated cardiomyopathy (AAC) is becoming an increasingly recognised entity. The characteristics and outcomes of these patients are poorly understood. Thirty patients admitted with heart failure and echocardiographic evidence of cardiomyopathy between 2005 and 2014 and who had a documented history of amphetamine abuse that was considered an important factor in the causation of their cardiomyopathy were retrospectively identified. Mean age at presentation was 40±10 years with a male predominance (n=25, 83%). The majority were of indigenous Maori ethnicity. At presentation, four patients were in cardiogenic shock. Five patients required intensive care unit (ICU) admission for inotropic support and mechanical ventilation. Fifteen had severe left ventricular (LV) dilation (mean LV end-diastolic dimension 6.8±1.0cm) and all patients had severe LV dysfunction (mean LV ejection fraction 22±8%). Despite optimal heart failure therapy, LV size remained significantly dilated with minimal improvement in LV function. During median follow-up of 18 months, five patients died from end-stage heart failure and 17 had at least one readmission with decompensated heart failure. Amphetamine-associated cardiomyopathy was seen predominantly in young indigenous Maori men. They presented with severe cardiomyopathy, often requiring ICU admission. Severe LV dilation and significant LV dysfunction persisted despite treatment and mortality was high. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  5. Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Meike [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Humboldt-University, Experimental and Clinical Research Center (ECRC), Charite Campus Buch, Berlin (Germany); Frauenrath, Tobias; Hezel, Fabian [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine, Berlin (Germany); Krombach, Gabriele A.; Kremer, Ute; Koppers, Benedikt [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Butenweg, Christoph; Goemmel, Andreas [Chair of Structural Statics and Dynamics, RWTH Aachen, Aachen (Germany); Utting, Jane F. [MRI, NHS Grampian, Aberdeen Royal Infirmary, Aberdeen (United Kingdom); Schulz-Menger, Jeanette [Humboldt-University, Working Group Cardiovascular MR, Franz-Volhard-Klinik, Department of Cardiology, HELIOS-Klinikum Berlin-Buch and Charite Campus Buch, Berlin (Germany); Niendorf, Thoralf [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Humboldt-University, Experimental and Clinical Research Center (ECRC), Charite Campus Buch, Berlin (Germany); Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine, Berlin (Germany)

    2010-06-15

    As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n = 14). Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT's performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct R-wave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects - even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived from VCG-triggered acquisitions (1.5 T: ESV{sub VCG} = (56 {+-} 17) ml, EDV{sub VCG} = (151 {+-} 32) ml, LVM{sub VCG} = (97 {+-} 27) g, SV{sub VCG} = (94 {+-} 19) ml, EF{sub VCG} = (63 {+-} 5)% cf. ESV{sub ACT} = (56 {+-} 18) ml, EDV{sub ACT} = (147 {+-} 36) ml, LVM{sub ACT} = (102 {+-} 29) g, SV{sub ACT} = (91 {+-} 22) ml, EF{sub ACT} = (62 {+-} 6)%; 3.0 T: ESV{sub VCG} = (55 {+-} 21) ml, EDV{sub VCG} = (151 {+-} 32) ml, LVM{sub VCG} = (101 {+-} 27) g, SV{sub VCG} = (96 {+-} 15) ml, EF{sub VCG} = (65 {+-} 7)% cf. ESV{sub ACT} = (54 {+-} 20) ml, EDV{sub ACT} = (146 {+-} 35) ml, LVM{sub ACT} = (101 {+-} 30) g, SV{sub ACT} = (92 {+-} 17) ml, EF{sub ACT} = (64 {+-} 6)%). ACT's intrinsic insensitivity to interference from electromagnetic fields renders it suitable for clinical CMR. (orig.)

  6. Evaluation of right ventricular volume and function by 2D and 3D echocardiography compared to MRI

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Petersen, Claus Leth; Kjaer, Andreas

    2005-01-01

    : Thirty-four subjects with (a) prior inferior ST-elevation myocardial infarction (n=17), (b) a history of pulmonary embolism and persistent dyspnea (n=7) or (c) normal subjects (n=10) had 2D and 3D echocardiography, SPECT and MRI within 24h. End-diastolic volume and peak tricuspid regurgitation velocity...... were increased in patients with a history of pulmonary embolism compared to healthy subjects, 130+/-26 ml vs. 94+/-26 ml, P... volume showed significant correlation to RV volumes by MRI. Tricuspid annular plane systolic excursion (TAPSE) had the better correlation to RVEF by MRI, r=0.48, P

  7. Agreement of left ventricular ejection fraction and volumes between adenosine stress TL-201 gated SPECT and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S. [College of Medicine, Univ. of Ewha, Seoul (Korea, Republic of); Moon, D. H.; Kim, H. M.; Yang, Y. J.; Kang, D. H. [Asan Medical Center, Seoul (Korea, Republic of)

    2003-07-01

    Electrocardiogram-gated TI-201 SPECT measurements of left ventricular ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) have shown high correlation with conventional methods. However, how much these parameters measured by TI-201 gated SPECT differ from those by echocardiography has not been assessed. Adenosine stress (Ad-G) and redistribution TI-201 gated SPECT (Re-G) and resting echocardiography were conducted in 337 patients (184 male, 153 female). EDV, ESV and LVEF measured by QGS software were compared with the results by echocardiography. Patients with arrhythmia (atrial fibrillation or frequent premature contractions) or evidence of fixed or reversible perfusion defects on TI-201 SPECT were excluded. EF, EDV and ESV measured by Ad-G (63.3{+-}9.8,73.8{+-}30.2,29.1{+-}20.1) and Re-G (65.2{+-}11.6,69.1{+-}30.1,26.5{+-}20.3) correlated well with those by Echo (61.4{+-}7.9,78.3{+-}2.7, 30.7{+-} 17.5 ; r of Ad-G=0.547, 0.850, 0.827, p<0.001 ; r of Re-G=0.585, 0.838, 0.819, p<0.001). However the difference (mean, SD, SEE of Echo - gated SPECT) was statistically significant (EF: Ad-G=1.71, 8.92, 0.48, Re-G=3.59, 10.39, 0.56, p<0.001 ; EDV: Ad-G=4.75, 16.21, 0.88, Re-G=9.53, 16.77, 0.91, p<0.001 ; ESV: Ad-G=1.75, 11.35, 0.61, p<0.05, Re-G=4.29, 11.7, 0.63, p<0.001). Bland-Altman plots showed that the difference of EDV and ESV did not vary in any systematic way over the range of measurement, whereas the difference of EF increased with increasing average EF by Echo and gated-SPECT. The difference of EF, EDV, and ESV between Ad-G and Echo was significantly smaller than those between Re-G and Echo (p<0.001). Gated TI-201 SPECT underestimates EDV and ESV over a wide range of volume. As a result, EF by gated TI-201 SPECT is overestimated especially in patients with small LV volume. Ad-G is preferable to Re-G in assessing left ventricular ejection fraction and volume in place of Echo because of smaller bias.

  8. Cardiac time intervals by tissue Doppler imaging M-mode echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor

    2016-01-01

    for myocardial myocytes to achieve an LV pressure equal to that of aorta increases, resulting in a prolongation of the isovolumic contraction time (IVCT). Furthermore, the ability of myocardial myocytes to maintain the LV pressure decreases, resulting in reduction in the ejection time (ET). As LV diastolic...... of whether the LV is suffering from impaired systolic or diastolic function. A novel method of evaluating the cardiac time intervals has recently evolved. Using tissue Doppler imaging (TDI) M-mode through the mitral valve (MV) to estimate the cardiac time intervals may be an improved method reflecting global...

  9. Decreased right heart blood volume determined by magnetic resonance imaging: evidence of central underfilling in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Søndergaard, L; Møgelvang, J

    1995-01-01

    mL, NS), and left atrial volume (70 vs. 57 mL, P = .08) were normal or slightly increased. The right ejection fraction (68% vs. 53%, P fraction was slightly reduced (61% vs. 69%, NS). The central and arterial blood volume (CBV), assessed......Whether the central blood volume is reduced or expanded in cirrhosis is still under debate. Accordingly, the current study was undertaken to assess the volume of the heart cavities. Ten cirrhotic patients and matched controls had their right and left ventricular end-diastolic volumes (RVDV and LVDV...... as the cardiac output (CO) multiplied by the central circulation time, was significantly decreased (1.47 vs. 1.81 L, P blood volume (4.43 vs. 3.64 L, P

  10. Global longitudinal strain and its dynamics after replacement of aortal valve in patients with severe aortic stenosis

    Directory of Open Access Journals (Sweden)

    N.V. Ponych

    2017-09-01

    Full Text Available The aim – to determine factors that may influence the global longitudinal strain (GLS and its dynamics after replacement aortic valve (RAV in patients with severe aortic stenosis (AS. Materials and methods. In a one-center prospective study, 30 patients with severe AS were sequentially screened for RAV surgery. Among them there were 16 (53,3 % men and 14 (46,7 % women. The median age was 63 (range from 46 to 77, quartiles 57–69 years. All patients underwent clinical and instrumental study, including transthoracic echocardiography (TTE and coronary angiography. In the early postoperative period and 6–12 months after surgery, all patients performed a repeat TTE according to a standard protocol that included an assessment of the GLS. GLS data and their dynamics was performed in the groups of patients with preserved (n = 18 and low (n = 12 left ventricular ejection fraction (LV EF. Results. In patients with preserved LV EF, the median of the preoperative GLS was –12 % (in the quartiles from –15 to –11 %, postoperative GLS –11 % (quartiles from –11 to –9 %. In patients with reduced LV EF, the median of the preoperative GLS was –6 % (from –8.5 to –4 % for quartiles, –8.5 % for postoperative GLS (from –10 to –6 % for quartiles (p < 0.001 for comparison of baseline and p < 0.05 relative to differences in dynamics of GLS in comparable groups. In the examined patients, significant correlations were found between baseline GLS with functional class of heart failure, concomitant tricuspid insufficiency, atrial fibrillation, duration of QRS complex, LV EF, end-diastolic, endsystolic volume index (EDV, ESV and volume left atrium (LA, left ventricular myocardial mass index, aortic valve orifice area index, E/A ratio, and Thei index. In turn, the positive dynamics of GLS significantly depended on the initial functional class of heart failure, the stage of arterial hypertension, the degree of tricuspid insufficiency, LV EF, the index

  11. Assessment of left ventricular deformation in patients with Ebstein’s anomaly by cardiac magnetic resonance tissue tracking

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xi; Zhang, Qin [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Yang, Zhi-gang, E-mail: yangzg666@163.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Shi, Ke; Xu, Hua-yan [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Xie, Lin-jun [Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041 (China); Jiang, Li; Diao, Kai-yue [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Guo, Ying-kun [Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041 (China)

    2017-04-15

    Purpose: The aim of this study was to clarify the feasibility of myocardial strain using cardiovascular magnetic resonance (CMR) for the evaluation of left ventricular (LV) deformation in patients with Ebstein’s anomaly (EA). Materials and methods: We recruited 32 patients with EA and 30 controls for CMR examination and measured LV function, dimension and tissue tracking parameters (the global and regional radial, circumferential and longitudinal peak strain), together with the right ventricle (RV) dimension. LV strain parameters were compared among the controls, patients with preserved LV ejection fraction (LVEF; ≥55%), and patients with reduced LVEF (<55%). Pearson’s correlation was used to evaluate relationships between tissue tracking parameters with the RVEDD/LVEDD index and LVEF. An ROC analysis was also performed to determine whether the cut-off values for PS could be used to differentiate LV dysfunction between patients with EA and controls. The intraclass correlation coefficient (ICC) was used to assess the inter- and intra-observer variability. Results: The global strain parameters all decreased significantly in the EA group compared with the control group (all P < 0.05). Furthermore, the global radial and circumferential peak strain (PS) were obviously even lower in the reduced LVEF group than the strain measured in preserved LVEF groups (28.64% vs. 37.39%, p < 0.05; and −8.20% vs. −17.89%; p < 0.05; respectively). The regional strain abnormalities in EA patients were mainly involved in basal and middle segments. The results also demonstrated a significant correlation between the ratio of the RV end-diastolic dimension to the LV end-diastolic dimension (RVEDD/LVEDD index) with the global circumferential PS (r = 0.508) and the longitudinal PS (r = 0.474), as well as a good correlation between radial PS and LVEF (r = 0.465). The ICCs for intra- and inter-observer variability were 0.797–0.904 and 0.701–0.896. Conclusions: LV strain serves an

  12. Back-end interconnection. A generic concept for high volume manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Bosman, J.; Budel, T.; De Kok, C.J.G.M.

    2013-10-15

    The general method to realize series connection in thin film PV modules is monolithical interconnection through a sequence of laser scribes (P1, P2 and P3) and layer depositions. This method however implies that the deposition processes are interrupted several times, an undesirable situation in high volume processing. In order to eliminate this drawback we focus our developments on the so called 'back-end interconnection concept' in which series interconnection takes place AFTER the deposition of the functional layers of the thin film PV device. The process of making a back-end interconnection combines laser scribing, curing, sintering and inkjet processes. These different processes interacts with each other and are investigated in order to create processing strategies that are robust to ensure high volume production. The generic approach created a technology base that can be applied to any thin film PV technology.

  13. Impact of Hepatocyte Growth Factor on Skeletal Myoblast Transplantation Late after Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Stacy B. O'blenes

    2013-01-01

    Full Text Available In clinical studies, skeletal myoblast (SKMB transplantation late after myocardial infarction (MI has minimal impact on left ventricular (LV function. This may be related to our previous observation that the extent of SKMB engraftment is minimal in chronic MI when compared to acute MI, which correlates with decreased hepatocyte growth factor (HGF expression, an important regulator of SKMB function. Here, we investigated delivery of exogenous HGF as a strategy for augmenting SKMB engraftment late after MI. Rats underwent SKMB transplantation 4 weeks after coronary ligation. HGF or vehicle control was delivered intravenously during the subsequent 2 weeks. LV function was assessed by MRI before and 2 weeks after SKMB transplantation. We evaluated HGF delivery, SKMB engraftment, and expression of genes associated with post-MI remodeling. Serum HGF was 6.2 ± 2.4 ng/mL after 2 weeks of HGF infusion (n = 7, but undetectable in controls (n = 7. LV end-diastolic volume and ejection fraction did not improve with HGF treatment (321 ± 27 mm 3 , 42% ± 2% vs. 285 ± 33 mm 3 , 43% ± 2%, HGF vs. control. MIs were larger in HGF-treated animals (50 ± 7 vs. 30 ± 6 mm 3 , P = 0.046, but the volume of engrafted SKMBs or percentage of MIs occupied by SKMBs did not increase with HGF (1.7 ± 0.3 mm 3 , 4.7% ± 1.9% vs. 1.4 ± 0.4 mm 3 , 5.3% ± 1.6%, HGF vs. control. Expression of genes associated with post-infarction remodeling was not altered by HGF. Delivery of exogenous HGF failed to augment SKMB engraftment and functional recovery in chronic MI. Expression of genes associated with LV remodeling was not altered by HGF. Alternative strategies to enhance engraftment of SKMB must be explored to optimize the clinical efficacy of SKMB transplantation.

  14. Hemodynamic responses to external counterbalancing of auto-positive end-expiratory pressure in mechanically ventilated patients with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Baigorri, F; de Monte, A; Blanch, L; Fernández, R; Vallés, J; Mestre, J; Saura, P; Artigas, A

    1994-11-01

    To study the effect of positive end-expiratory pressure (PEEP) on right ventricular hemodynamics and ejection fraction in patients with chronic obstructive pulmonary disease and positive alveolar pressure throughout expiration by dynamic hyperinflation (auto-PEEP). Open, prospective, controlled trial. General intensive care unit of a community hospital. Ten patients sedated and paralyzed with an acute exacerbation of chronic obstructive pulmonary disease undergoing mechanical ventilation. Insertion of a pulmonary artery catheter modified with a rapid response thermistor and a radial arterial catheter. PEEP was then increased from 0 (PEEP 0) to auto-PEEP level (PEEP = auto-PEEP) and 5 cm H2O above that (PEEP = auto-PEEP +5). At each level of PEEP, airway pressures, flow and volume, hemodynamic variables (including right ventricular ejection fraction by thermodilution technique), and blood gas analyses were recorded. The mean auto-PEEP was 6.6 +/- 2.8 cm H2O and the total PEEP reached was 12.2 +/- 2.4 cm H2O. The degree of lung inflation induced by PEEP averaged 145 +/- 87 mL with PEEP = auto-PEEP and 495 +/- 133 mL with PEEP = auto-PEEP + 5. The PEEP = auto-PEEP caused a right ventricular end-diastolic pressure increase, but there was no other significant hemodynamic change. With PEEP = auto-PEEP + 5, there was a significant increase in intravascular pressures; this amount of PEEP reduced cardiac output (from 4.40 +/- 1.38 L/min at PEEP 0 to 4.13 +/- 1.48 L/min; p 10% in only five cases and this group of patients had significantly lower right ventricular volumes than the group with less cardiac output variation (right ventricular end-diastolic volume: 64 +/- 9 vs. 96 +/- 26 mL/m2; right ventricular end-systolic volume: 38 +/- 6 vs. 65 +/- 21 mL/m2; p < .05) without significant difference in the other variables that were measured. Neither right ventricular ejection fraction nor right ventricle volumes changed as PEEP increased, but there were marked interpatient

  15. Biodegradation of di-n-butyl phthalate by bacterial consortium LV-1 enriched from river sludge.

    Directory of Open Access Journals (Sweden)

    Yangyang Wang

    Full Text Available A stable bacterial consortium (LV-1 capable of degrading di-n-butyl phthalate (DBP was enriched from river sludge. Community analysis revealed that the main families of LV-1 are Brucellaceae (62.78% and Sinobacteraceae (14.83%, and the main genera of LV-1 are Brucella spp. (62.78% and Sinobacter spp. (14.83%. The optimal pH and temperature for LV-1 to degrade DBP were pH 6.0 and 30°C, respectively. Inoculum size influenced the degradation ratio when the incubation time was < 24 h. The initial concentration of DBP also influenced the degradation rates of DBP by LV-1, and the degradation rates ranged from 69.0-775.0 mg/l/d in the first 24 h. Degradation of DBP was best fitted by first-order kinetics when the initial concentration was < 300 mg/l. In addition, Cd2+, Cr6+, and Zn2+ inhibited DBP degradation by LV-1 at all considered concentrations, but low concentrations of Pb2+, Cu2+, and Mn2+ enhanced DBP degradation. The main intermediates (mono-ethyl phthalate [MEP], mono-butyl phthalate [MBP], and phthalic acid [PA] were identified in the DBP degradation process, thus a new biochemical pathway of DBP degradation is proposed. Furthermore, LV-1 also degraded other phthalates with shorter ester chains (DMP, DEP, and PA.

  16. Left ventricular function in chronic aortic regurgitation

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Manno, B.; Amenta, A.; Kane, S.A.

    1983-01-01

    Left ventricular performance was determined in 42 patients with moderate or severe aortic regurgitation during upright exercise by measuring left ventricular ejection fraction and volume with radionuclide ventriculography. Classification of the patients according to exercise tolerance showed that patients with normal exercise tolerance (greater than or equal to 7.0 minutes) had a significantly higher ejection fraction at rest (probability [p] . 0.02) and during exercise (p . 0.0002), higher cardiac index at exercise (p . 0.0008) and lower exercise end-systolic volume (p . 0.01) than did patients with limited exercise tolerance. Similar significant differences were noted in younger patients compared with older patients in ejection fraction at rest and exercise (both p . 0.001) and cardiac index at rest (p . 0.03) and exercise (p . 0.0005). The end-diastolic volume decreased during exercise in 60% of the patients. The patients with a decrease in volume were significantly younger and had better exercise tolerance and a larger end-diastolic volume at rest than did patients who showed an increase in volume. The mean corrected left ventricular end-diastolic radius/wall thickness ratio was significantly greater in patients with abnormal than in those with normal exercise reserve (mean +/- standard deviation 476 +/- 146 versus 377 +/- 92 mm Hg, p less than 0.05). Thus, in patients with chronic aortic regurgitation: 1) left ventricular systolic function during exercise was related to age, exercise tolerance and corrected left ventricular end-diastolic radius/wall thickness ratio, and 2) the end-diastolic volume decreased during exercise, especially in younger patients and patients with normal exercise tolerance or a large volume at rest

  17. EV Charging Facilities and Their Application in LV Feeders with Photovoltaics

    DEFF Research Database (Denmark)

    Marra, Francesco; Yang, Guangya; Træholt, Chresten

    2013-01-01

    Low-voltage (LV) grid feeders with high penetration of photovoltaics (PVs) are often affected by voltage magnitude problems. To solve such issues, previous research has shown that reactive power methods, active power curtailment and grid reinforcement can be used for voltage support, yet showing...... several limits. We introduce the use of electric vehicle (EV) public charging stations with energy storage system (ESS) as a solution for voltage regulation in LV feeders with PV. A novel method is proposed to determine the ESS charging load required for voltage regulation and compare the results...... for the different locations in the feeder. With time-series simulations, we quantify the energy size required for a station ESS. A Belgian LV residential grid, modeled using real PV generation and load profiles, is used as case study. The method and simulation results show the effectiveness of using public EV...

  18. Left ventricular functions in children with newly diagnosed Graves' disease. A single-center study from Upper Egypt.

    Science.gov (United States)

    Metwalley, Kotb Abbass; Farghaly, Hekma Saad; Abdelhamid, Abdelrahman

    2018-01-01

    This study aimed to evaluate the left ventricular (LV) functions in a cohort of children with Graves' disease (GD). This is a cross-sectional case-control study. It included 36 children with GD and 36 healthy children matched for age and gender. Thyroid hormones (TSH, FT4, and FT3) and anti-thyroid autoantibodies [anti-thyroid peroxidase (anti-TPO), thyrotropin receptor (TRAbs), and thyroglobulin antibodies] were measured. Conventional and tissue Doppler imaging (TDI) echocardiographies were used to assess left ventricular systolic and diastolic functions. LV mass index (LVMI) and myocardial performance index (MPI) were also measured. Compared to healthy children, conventional echocardiography of patients with GD revealed higher LVMI (P = 0.001) indicating LV hypertrophy but normal LV functions while TDI revealed lower Em/Am ratio indicating LV diastolic dysfunction (P = 0.001). Significant correlations were reported between FT4 with LVMI (P = 0.05), Em/Am (P = 0.01), and MPI (P = 0.01). In multivariate analysis, a positive correlation was identified between FT4 with MPI (OR = 1.17; 95% CI = 1.09-1.15; P = 0.001). Children with newly diagnosed GD may have significant subclinical changes in LV structure and function (diastolic and global). TDI is more sensitive than conventional Doppler in detecting LV dysfunction. These findings highlight the importance of early monitoring of children with GD for left ventricular mass index and diastolic function. What is Known: • There is an increased risk for cardiac abnormalities in children with Graves' disease (GD). • Limited studies assessed left ventricular function in patients with GD. What is New: • Children with newly diagnosed GD may have significant subclinical changes in left ventricular structure and functions. • Children with newly diagnosed GD should be monitored for left ventricular mass index and diastolic function.

  19. 'Motion frozen' quantification and display of myocardial perfusion gated SPECT

    International Nuclear Information System (INIS)

    Slomka, P.J.; Hurwitz, G.A.; Baddredine, M.; Baranowski, J.; Aladl, U.E.

    2002-01-01

    Aim: Gated SPECT imaging incorporates both functional and perfusion information of the left ventricle (LV). However perfusion data is confounded by the effect of ventricular motion. Most existing quantification paradigms simply add all gated frames and then proceed to extract the perfusion information from static images, discarding the effects of cardiac motion. In an attempt to improve the reliability and accuracy of cardiac SPECT quantification we propose to eliminate the LV motion prior to the perfusion quantification via automated image warping algorithm. Methods: A pilot series of 14 male and 11 female gated stress SPECT images acquired with 8 time bins have been co-registered to the coordinates of the 3D normal templates. Subsequently the LV endo and epi-cardial 3D points (300-500) were identified on end-systolic (ES) and end-diastolic (ED) frames, defining the ES-ED motion vectors. The nonlinear image warping algorithm (thin-plate-spline) was then applied to warp end-systolic frame was onto the end-diastolic frames using the corresponding ES-ED motion vectors. The remaining 6 intermediate frames were also transformed to the ED coordinates using fractions of the motion vectors. Such warped images were then summed to provide the LV perfusion image in the ED phase but with counts from the full cycle. Results: The identification of the ED/ES corresponding points was successful in all cases. The corrected displacement between ED and ES images was up to 25 mm. The summed images had the appearance of the ED frames but have been much less noisy since all the counts have been used. The spatial resolution of such images appeared higher than that of summed gated images, especially in the female scans. These 'motion frozen' images could be displayed and quantified as regular non-gated tomograms including polar map paradigm. Conclusions: This image processing technique may improve the effective image resolution of summed gated myocardial perfusion images used for

  20. PREVENTION OF LEFT VENTRICLE SYSTOLIC DYSFUNCTION IN PATIENTS WITH ACUTE CORONARY SYNDROME WITH ST SEGMENT ELEVATION AFTER CARDIAC REVASCULARIZATION

    Directory of Open Access Journals (Sweden)

    A. L. Alyavi

    2016-01-01

    Full Text Available Aim. To study effects of bioflavonoid quercetin (corvitin on left ventricle (LV systolic dysfunction in patients with acute coronary syndrome with ST segment elevation (ACS+ST after cardiac revascularization.Material and methods. 60 patients with ACS+ST (44,2±1,3 y.o. were examined. Patients were admitted to hospital within 6 hours after complaints beginning. Patients were randomized in two groups. 30 patients of group A had standard therapy and cardiac revascularization. 30 patients of group B received corvitin additionally to standard therapy before cardiac revascularization. Echocardiography initially and stress-echocardiography with dobutamine after status stabilization (at 8-10 days of disease were performed.Results. Dobutamine test (with low and high doses showed myocardial viability in patients of group B. Patients of group A had irreversible LV systolic dysfunction in 32 % of segments. Corvitin slowed down LV dilatation progression in patients with ACS+ST. It resulted in the end-diastolic and end-systolic indexes did not change within 10 days. The LV ejection fraction was more increased in patients of group B in comparison with patients of group A.Conclusion. The early corvitin prescribing has positive effects on LV systolic function and prevents post-reperfusion complications. 

  1. PREVENTION OF LEFT VENTRICLE SYSTOLIC DYSFUNCTION IN PATIENTS WITH ACUTE CORONARY SYNDROME WITH ST SEGMENT ELEVATION AFTER CARDIAC REVASCULARIZATION

    Directory of Open Access Journals (Sweden)

    A. L. Alyavi

    2009-01-01

    Full Text Available Aim. To study effects of bioflavonoid quercetin (corvitin on left ventricle (LV systolic dysfunction in patients with acute coronary syndrome with ST segment elevation (ACS+ST after cardiac revascularization.Material and methods. 60 patients with ACS+ST (44,2±1,3 y.o. were examined. Patients were admitted to hospital within 6 hours after complaints beginning. Patients were randomized in two groups. 30 patients of group A had standard therapy and cardiac revascularization. 30 patients of group B received corvitin additionally to standard therapy before cardiac revascularization. Echocardiography initially and stress-echocardiography with dobutamine after status stabilization (at 8-10 days of disease were performed.Results. Dobutamine test (with low and high doses showed myocardial viability in patients of group B. Patients of group A had irreversible LV systolic dysfunction in 32 % of segments. Corvitin slowed down LV dilatation progression in patients with ACS+ST. It resulted in the end-diastolic and end-systolic indexes did not change within 10 days. The LV ejection fraction was more increased in patients of group B in comparison with patients of group A.Conclusion. The early corvitin prescribing has positive effects on LV systolic function and prevents post-reperfusion complications. 

  2. Knowledge-based reconstruction for measurement of right ventricular volumes on cardiovascular magnetic resonance images in a mixed population.

    Science.gov (United States)

    Pieterman, Elise D; Budde, Ricardo P J; Robbers-Visser, Daniëlle; van Domburg, Ron T; Helbing, Willem A

    2017-09-01

    Follow-up of right ventricular performance is important for patients with congenital heart disease. Cardiac magnetic resonance imaging is optimal for this purpose. However, observer-dependency of manual analysis of right ventricular volumes limit its use. Knowledge-based reconstruction is a new semiautomatic analysis tool that uses a database including knowledge of right ventricular shape in various congenital heart diseases. We evaluated whether knowledge-based reconstruction is a good alternative for conventional analysis. To assess the inter- and intra-observer variability and agreement of knowledge-based versus conventional analysis of magnetic resonance right ventricular volumes, analysis was done by two observers in a mixed group of 22 patients with congenital heart disease affecting right ventricular loading conditions (dextro-transposition of the great arteries and right ventricle to pulmonary artery conduit) and a group of 17 healthy children. We used Bland-Altman analysis and coefficient of variation. Comparison between the conventional method and the knowledge-based method showed a systematically higher volume for the latter group. We found an overestimation for end-diastolic volume (bias -40 ± 24 mL, r = .956), end-systolic volume (bias -34 ± 24 mL, r = .943), stroke volume (bias -6 ± 17 mL, r = .735) and an underestimation of ejection fraction (bias 7 ± 7%, r = .671) by knowledge-based reconstruction. The intra-observer variability of knowledge-based reconstruction varied with a coefficient of variation of 9% for end-diastolic volume and 22% for stroke volume. The same trend was noted for inter-observer variability. A systematic difference (overestimation) was noted for right ventricular size as assessed with knowledge-based reconstruction compared with conventional methods for analysis. Observer variability for the new method was comparable to what has been reported for the right ventricle in children and congenital

  3. Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration

    DEFF Research Database (Denmark)

    Nielsen, Jan Møller; Kristiansen, Steen B; Ringgaard, Steffen

    2007-01-01

    in mice (n = 52) with a Millar CC (SPR-839) and compared with MRI-derived volumes (V(MRI)). Significant correlations between V(CC) and V(MRI) [end-diastolic volume (EDV): R(2) = 0.85, P 2) = 0.88, P ... in the pulmonary artery was used to calibrate for parallel conductance and volume conversion was done by individual cylinder calibration. However, a significant underestimation was observed [EDV = -17.3 microl (-22.7 to -11.9 microl); ESV = -8.8 microl (-12.5 to -5.1 microl)]. Intravenous injection....... The dual-frequency method for estimation of parallel conductance failed to produce V(CC) that correlated with V(MRI). We conclude that selection of the calibration procedure for the CC has significant implications for the accuracy and precision of volume estimation and pressure-volume loop...

  4. Evaluation of impaired left ventricular ejection fraction and increased dimensions by multiple neurohumoral plasma concentrations

    DEFF Research Database (Denmark)

    Grønning, Bjørn Aaris; Nilsson, Jens C; Søndergaard, Lars

    2001-01-01

    failure. METHODS: Forty-eight patients with symptomatic heart failure were examined with blood samples and magnetic resonance imaging along with 20 age and gender-matched normal controls. RESULTS: In multiple regression analyses, BNP was the strongest independent marker for LV end-diastolic (r=0.71, P....0001), and end-systolic (r=0.75, Pr=0.69, Pr=-0.78, Pr=0.76, Pr=0.78, Pr=0.71, P....0001 (ENDO/BNP)], and ALDO for LVEF [r=-0.81, P

  5. Myocardial deformation assessed by longitudinal strain. Chamber specific normative data for CMR-feature tracking from the German competence network for congenital heart defects

    International Nuclear Information System (INIS)

    Shang, Quanliang; Patel, Shivani; Danford, David A.; Kutty, Shelby; Steinmetz, Michael; Schuster, Andreas; Beerbaum, Philipp; Sarikouch, Samir

    2018-01-01

    Left ventricular two-dimensional global longitudinal strain (LS) is superior to ejection fraction (EF) as predictor of outcome. We provide reference data for atrial and ventricular global LS during childhood and adolescence by CMR feature tracking (FT). We prospectively enrolled 115 healthy subjects (56 male, mean age 12.4 ± 4.1 years) at a single institution. CMR consisted of standard two-dimensional steady-state free-precession acquisitions. CMR-FT was performed on ventricular horizontal long-axis images for derivation of right and left atrial (RA, LA) and right and left ventricular (RV, LV) peak global LS. End-diastolic volumes (EDVs) and EF were measured. Correlations were explored for LS with age, EDV and EF of each chamber. Mean±SD of LS (%) for RA, RV, LA and LV were 26.56±10.2, -17.96±5.4, 26.45±10.6 and -17.47±5, respectively. There was a positive correlation of LS in LA, LV, RA and RV with corresponding EF (all P<0.05); correlations with age were weak. Gender-wise differences were not significant for atrial and ventricular LS, strain rate and displacement. Inter- and intra-observer comparisons showed moderate agreements. Chamber-specific nomograms for paediatric atrial and ventricular LS are provided to serve as clinical reference, and to facilitate CMR-based deformation research. (orig.)

  6. Myocardial deformation assessed by longitudinal strain. Chamber specific normative data for CMR-feature tracking from the German competence network for congenital heart defects

    Energy Technology Data Exchange (ETDEWEB)

    Shang, Quanliang [University of Nebraska College of Medicine, Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Central South University, Department of Radiology, Second Xiangya Hospital, Changsha, Hunan Province (China); Patel, Shivani; Danford, David A.; Kutty, Shelby [University of Nebraska College of Medicine, Children' s Hospital and Medical Center, Division of Pediatric Cardiology, Omaha, NE (United States); Steinmetz, Michael [Georg-August-University and German Centre for Cardiovascular Research (DZHK, Partner Site), Department of Paediatric Cardiology, Goettingen (Germany); Schuster, Andreas [Georg-August-University and German Centre for Cardiovascular Research (DZHK, Partner Site), Department of Cardiology and Pulmonology, Goettingen (Germany); Beerbaum, Philipp; Sarikouch, Samir [Hanover Medical School, Hanover (Germany)

    2018-03-15

    Left ventricular two-dimensional global longitudinal strain (LS) is superior to ejection fraction (EF) as predictor of outcome. We provide reference data for atrial and ventricular global LS during childhood and adolescence by CMR feature tracking (FT). We prospectively enrolled 115 healthy subjects (56 male, mean age 12.4 ± 4.1 years) at a single institution. CMR consisted of standard two-dimensional steady-state free-precession acquisitions. CMR-FT was performed on ventricular horizontal long-axis images for derivation of right and left atrial (RA, LA) and right and left ventricular (RV, LV) peak global LS. End-diastolic volumes (EDVs) and EF were measured. Correlations were explored for LS with age, EDV and EF of each chamber. Mean±SD of LS (%) for RA, RV, LA and LV were 26.56±10.2, -17.96±5.4, 26.45±10.6 and -17.47±5, respectively. There was a positive correlation of LS in LA, LV, RA and RV with corresponding EF (all P<0.05); correlations with age were weak. Gender-wise differences were not significant for atrial and ventricular LS, strain rate and displacement. Inter- and intra-observer comparisons showed moderate agreements. Chamber-specific nomograms for paediatric atrial and ventricular LS are provided to serve as clinical reference, and to facilitate CMR-based deformation research. (orig.)

  7. Assessment of left ventricular filling in various heart disease, especially in ischemic heart disease, by ECG-gated cardiac blood pool scintigraphy

    International Nuclear Information System (INIS)

    Nakagawa, Hiroaki

    1986-01-01

    Using ECG-gated cardiac blood pool scintigraphy (BPS), left ventricular (LV) diastolic function was evaluated in various heart disease, especially in ischemic heart disease (IHD). LV function indices (2 systolic and 9 diastolic) were obtained from LV time activity curve derived from BPS. Among various diastolic indices, peak filling rate (PFR) and 2 other indices were significantly influenced by heart rate (HR), so corrected values for HR were used for this study. Various degrees of disturbance in diastolic filling were found in many cases without systolic impairment. According to the mechanism responsible for diastolic impairment, LV time activity curve showed a characteristic pattern. In IHD, filling disturbance in early diastole was observed before the impairment of systolic contraction developed, so it was thought to be an early predictor of cardiac failure. In the scar region of myocardial infarction (MI), decrease in regional ejection fraction and asynchrony in wall motion were shown, and these resulted in marked deterioration of early diastolic filling. On the other hand in angina pectoris (AP), such systolic disorders were not shown in the ischemic region perfused by stenotic coronary artery, although the disturbance of regional filling was found. The exercise capacity in AP was more related to the impairment in diastolic function at resting state than in systolic function, and furthermore the reserve of diastolic function as well as of systolic function was shown to be an important determinant of exercise capacity in AP. As HR increased, increase of PFR and decrease in time to peak filling was found, which was thought to be a sort of compensation for the shortening diastolic time due to increase in HR during exercise. Such compensation was decreased in AP with reduced exercise capacity. (J.P.N.)

  8. Evaluation of cardiac sympathetic nerve activity and aldosterone suppression in patients with acute decompensated heart failure on treatment containing intravenous atrial natriuretic peptide

    International Nuclear Information System (INIS)

    Kasama, Shu; Toyama, Takuji; Kurabayashi, Masahiko; Iwasaki, Toshiya; Sumino, Hiroyuki; Kumakura, Hisao; Minami, Kazutomo; Ichikawa, Shuichi; Matsumoto, Naoya; Nakata, Tomoaki

    2014-01-01

    Aldosterone prevents the uptake of norepinephrine in the myocardium. Atrial natriuretic peptide (ANP), a circulating hormone of cardiac origin, inhibits aldosterone synthase gene expression in cultured cardiocytes. We evaluated the effects of intravenous ANP on cardiac sympathetic nerve activity (CSNA) and aldosterone suppression in patients with acute decompensated heart failure (ADHF). We studied 182 patients with moderate nonischemic ADHF requiring hospitalization and treated with standard therapy containing intravenous ANP and 10 age-matched normal control subjects. ANP was continuously infused for >96 h. In all subjects, delayed total defect score (TDS), heart to mediastinum ratio, and washout rate were determined by 123 I-metaiodobenzylguanidine (MIBG) scintigraphy. Left ventricular (LV) end-diastolic volume, end-systolic volume, and ejection fraction were determined by echocardiography. All patients with acute heart failure (AHF) were examined once within 3 days and then 4 weeks after admission, while the control subjects were examined only once (when their hemodynamics were normal). Moreover, for 62 AHF patients, plasma aldosterone concentrations were measured at admission and 1 h before stopping ANP infusion. 123 I-MIBG scintigraphic and echocardiographic parameters in normal subjects were more favorable than those in patients with AHF (all p < 0.001). After treatment, all these parameters improved significantly in AHF patients (all p < 0.001). We also found significant correlation between percent changes of TDS and aldosterone concentrations (r = 0.539, p < 0.001) in 62 AHF patients. The CSNA and LV performance were all improved in AHF patients. Furthermore, norepinephrine uptake of myocardium may be ameliorated by suppressing aldosterone production after standard treatment containing intravenous ANP. (orig.)

  9. Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function

    International Nuclear Information System (INIS)

    Sandner, Torleif A.; Huber, Armin M.; Theisen, Daniel; Reiser, Maximilian F.; Wintersperger, Bernd J.; Houck, Philip; Runge, Val M.; Sincleair, Spencer

    2008-01-01

    The ability of fast, parallel-imaging-based cine magnetic resonance (MR) to monitor global cardiac function in longitudinal exams at 3 Tesla was evaluated. Seventeen patients with chronic cardiac disease underwent serial cine MR imaging exams (n=3) at 3 Tesla. Data were acquired in short-axis orientation using cine steady-state free precession (SSFP) with a spatial resolution of 2.5 x 1.9 mm 2 at 45 ms temporal resolution. Multislice imaging (three slices/breath-hold) was performed using TSENSE acceleration (R=3) and standard single-slice cine (non-TSENSE) was performed at identical locations in consecutive breath-holds. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and myocardial mass (MM) of both cine approaches were compared for individual time-points as well as for longitudinal comparison. TSENSE-cine did not show significant differences for EDV (2.6 ml; P=.79), ESV (2.2 ml; P=0.81), EF (-0.3%; P=0.95) and MM (2.4 g; P=0.72) in comparison with non-TSENSE. Longitudinal ANOVA analysis did not reveal significant differences for any parameter, neither for non-TSENSE data (all P>0.7) nor for TSENSE data (all P>0.9). Multifactorial ANOVA showed non-significant differences (all P>0.7) at comparable data variances. Data acquisition was significantly shortened using TSENSE. Threefold accelerated multislice cine at 3 Tesla allows accurate assessment of volumetric LV data and accurate longitudinal monitoring of global LV function at a substantially shorter overall examination time. (orig.)

  10. Noninvasive prediction of left ventricular end-diastolic pressure in patients with coronary artery disease and preserved ejection fraction.

    Science.gov (United States)

    Abd-El-Aziz, Tarek A

    2012-01-01

    The aim of this study was to compare 3 different available methods for estimating left ventricular end-diastolic pressure (LVEDP) noninvasively in patients with coronary artery disease and preserved left ventricular ejection fraction (EF). We used 3 equations for noninvasive estimation of LVEDP: The equation of Mulvagh et al., LVEDP(1) = 46 - 0.22 (IVRT) - 0.10 (AFF) - 0.03 (DT) - (2 ÷ E/A) + 0.05 MAR; the equation of Stork et al., LVEDP(2) = 1.06 + 15.15 × Ai/Ei; and the equation of Abd-El-Aziz, LVEDP(3) = [0.54 (MABP) × (1 - EF)] - 2.23. ( A, A-wave velocity; AFF, atrial filling fraction; Ai, time velocity integral of A wave; DT, deceleration time; E, E-wave velocity; Ei, time velocity integral of E wave; IVRT, isovolumic relaxation time; MABP, mean arterial blood pressure; MAR, time from termination of mitral flow to the electrocardiographic R wave; Ti, time velocity integral of total wave.) LVEDP measured by catheterization was correlated with LVEDP(1) (r = 0.52, P Aziz, LVEDP = [0.54 MABP × (1 - EF)] - 2.23, appears to be the most accurate, reliable, and easily applied method for estimating LVEDP noninvasively in patients with preserved left ventricular ejection fraction and an LVEDP < 20 mm Hg. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  11. Late gadolinium enhancement and adverse outcomes in a contemporary cohort of adult survivors of tetralogy of Fallot.

    Science.gov (United States)

    Dobson, Richard J; Mordi, Ify; Danton, Mark H; Walker, Niki L; Walker, Hamish A; Tzemos, Nikolaos

    2017-01-01

    Myocardial fibrosis has been associated with poorer outcomes in tetralogy of Fallot, however only a handful of studies have assessed its significance in the current era. Our aim was to quantify the amount of late gadolinium enhancement in both the LV and RV in a contemporary cohort of adults with surgically repaired tetralogy of Fallot, and assess the relationship with adverse clinical outcomes. Single centre cohort study SETTING: National tertiary referral center Patients: One hundred fourteen patients with surgically repaired tetralogy of Fallot with median age 29.5 years (range 17.5-64.2). Prospective follow-up for mean 2.4 years (SD 1.29). Cardiovascular magnetic resonance was performed, and late gadolinium enhancement mass was estimated for the LV using the 5-SD remote myocardium method, and for the RV using a segmental scoring system. Cohort characterization was determined through the use of a computerized database. Survival analysis from time of scan to first adverse event, defined as an episode of atrial arrhythmia, sustained ventricular arrhythmia, hospitalization with heart failure, or implantable cardioverter-defibrillator insertion. Eleven patients experienced an adverse outcome in the follow-up period, although there were no deaths. LV late gadolinium enhancement was associated with adverse outcomes in a univariate model (P = .027). However, when adjusted for age at scan the significant variables included NYHA class (P = .006), peak oxygen uptake (P = .028), number of prior sternotomies (P = .044), and higher indexed RV and LV end diastolic volumes (P = .002 and P tetralogy of Fallot survivors, however assessment particularly of the LV holds promise for the future. © 2016 Wiley Periodicals, Inc.

  12. Benazepril inhibited the NF-κB and TGF-β networking on LV hypertrophy in rats.

    Science.gov (United States)

    Yan, Shi-Hai; Zhao, Ning-Wei; Zhu, Xuan-Xuan; Wang, Qiong; Wang, Hai-Dan; Fu, Rui; Sun, Yuan; Li, Qi-Yi

    2013-05-01

    Benazepril, an angiotensin-converting enzyme (ACE) inhibitor, has been used to treat hypertension, congestive heart failure, and chronic renal failure. However, its biological activity and mechanism of action in inflammation are not fully identified. The present study was designed to determine the in vivo anti-inflammatory effects of benazepril on LV hypertrophy in rats. LV hypertrophy was produced in rats by abdominal aortic coarctation. They were then divided into the following groups: sham operation; LV hypertrophy; LV hypertrophy+benazepril (1mg/kg in a gavage, once a day for 4 weeks). Both morphological assays (hemodynamic and hemorheological measurement; LV hypertrophy assessment), and molecular assays (protein levels of Collagen type I/III, TNF-α and VCAM-1; TGF-β gene expression; NF-κB or Smad activation; intracellular ROS production) were performed. The following effects were observed in rats treated with benazepril: (1) marked improvements in hemodynamic and hemorheological parameters; (2) significant reductions in LV hypertrophy, dilatation and fibrosis; (3) significantly attenuated protein levels of Collagen type I/III, TGF-β, TNF-α and VCAM-1, NF-κB or Smad activation, as well as intracellular ROS production. These results suggest that the anti-inflammatory properties of benazepril may be ascribed to their down-regulation of both NF-κB and TGF-β signaling pathways by acting on the intracellular ROS production in rats with LV hypertrophy, thus supporting the use of benazepril as an anti-inflammatory agent. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Changes in Left Ventricular Morphology and Function After Mitral Valve Surgery

    Science.gov (United States)

    Shafii, Alexis E.; Gillinov, A. Marc; Mihaljevic, Tomislav; Stewart, William; Batizy, Lillian H.; Blackstone, Eugene H.

    2015-01-01

    Degenerative mitral valve disease is the leading cause of mitral regurgitation in North America. Surgical intervention has hinged on symptoms and ventricular changes that develop as compensatory ventricular remodeling takes place. In this study, we sought to characterize the temporal response of left ventricular (LV) morphology and function to mitral valve surgery for degenerative disease, and identify preoperative factors that influence reverse remodeling. From 1986–2007, 2,778 patients with isolated degenerative mitral valve disease underwent valve repair (n=2,607/94%) or replacement (n=171/6%) and had at least 1 postoperative transthoracic echocardiogram (TTE); 5,336 TTEs were available for analysis. Multivariable longitudinal repeated-measures analysis was performed to identify factors associated with reverse remodeling. LV dimensions decreased in the first year after surgery (end-diastolic from 5.7±0.80 to 4.9±1.4 cm; end-systolic from 3.4±0.71 to 3.1±1.4 cm). LV mass index decreased from 139±44 to 112±73 g·m−2. Reduction of LV hypertrophy was less pronounced in patients with greater preoperative left heart enlargement (P.2). In conclusion, a positive response toward normalization of LV morphology and function after mitral valve surgery is greatest in the first year. The best response occurs when surgery is performed before left heart dilatation, LV hypertrophy, or LV dysfunction develop. PMID:22534055

  14. Clinical application of a right ventricular pressure-volume loop determined by gated blood-pool imaging and simultaneously measured right ventricular pressure

    International Nuclear Information System (INIS)

    Yasue, Takao; Watanabe, Sachiro; Sugishita, Nobuyoshi; Tanaka, Tsutomu; Yokoyama, Hideo

    1983-01-01

    The data obtained by ECG-gated radionuclide angiography were collected simultaneously with right ventricular pressure and thermal cardiac output (CO) obtained by a Swan-Ganz catheter in Scintipac 1200 (Shimazu Co) in order to create a right ventricular pressure-volume (RV P-V) loop. Subjects consisted of 15 patients with old myocardial infarction (MI group), seven with angina pectoris (AP group), six with congestive cardiomyopathy (CCM group) and five with neurocirculatory asthenia (NCA group). Right ventricular end-diastolic volume (RVEDV) was calculated as RVEDV = CO/(EF x HR) (CO = cardiac output; HR = heart rate). Systolic work (W sub(S)), diastolic work (W sub(D)) and net work (W sub(N)) were calculated from a RV P-V loop by Simpson's method. The measurements were performed before and 5 min after sublingual administration of nitroglycerin (NG) (0.3 mg). The results were as follows: 1. RV P-V loops shifted towards the left lower part of the P-V plane after sublingual administration of nitroglycerin, indicating the reduction of pressure and volume of the right ventricle. 2. Right ventricular ejection fraction (RVEF) in the MI, AP and CCM groups showed smaller values than that of the NCA group. 3. Right ventricular end-diastolic volume index (RVEDVI) showed a converse relation with RVEF. 4. Cardiac index in all groups decreased after NG and a statistical significance was seen in the MI, AP and NCA groups (p<0.05). 5. RV W sub(S), RV W sub(D) and RV W sub(N) showed no difference among each groups in the control state, and significantly decreased after NG. We conclude that the present method using RV P-V loop might be useful as a noninvasive bedside monitoring and permits the evaluation of RV function in a clinical setting

  15. Plasma brain natriuretic peptide concentrations in patients with valvular heart disease

    Science.gov (United States)

    Stewart, Ralph A; Lee, Mildred; Gabriel, Ruvin; Van Pelt, Niels; Newby, David E; Kerr, Andrew J

    2016-01-01

    Objective Plasma brain natriuretic peptide (BNP) concentrations predict prognosis in patients with valvular heart disease (VHD), but it is unclear whether this directly relates to disease severity. We assessed the relationship between BNP and echocardiographic measures of disease severity in patients with VHD. Methods Plasma BNP concentrations were measured in patients with normal left ventricular (LV) systolic function and isolated VHD (mitral regurgitation (MR), n=33; aortic regurgitation (AR), n=39; aortic stenosis (AS), n=34; mitral stenosis (MS), n=30), and age-matched and sex-matched controls (n=39) immediately prior to exercise stress echocardiography. Results Compared with controls, patients with VHD had elevated plasma BNP concentrations (MR median 35 (IQR 23–52), AR 34 (22–45), AS 31 (22–60), MS 58 (34–90); controls 24 (16–33) pg/mL; p<0.01 for all). LV end diastolic volume index varied by valve lesion; (MR (mean 77±14), AR (91±28), AS (50±17), MS (43±11), controls (52±13) mL/m2; p<0.0001). There were no associations between LV volume and BNP. Left atrial (LA) area index varied (MR (18±4 cm2/m2), AR (12±2), AS (11±3), MS (19±6), controls (11±2); p<0.0001), but correlated with plasma BNP concentrations: MR (r=0.42, p=0.02), MS (r=0.86, p<0.0001), AR (r=0.53, p=0.001), AS (r=0.52, p=0.002). Higher plasma BNP concentrations were associated with increased pulmonary artery pressure and reduced exercise capacity. Despite adverse cardiac remodelling, 81 (60%) patients had a BNP concentration within the normal range. Conclusions Despite LV remodelling, plasma BNP concentrations are often normal in patients with VHD. Conversely, mild elevations of BNP occur with LA dilatation in the presence of normal LV. Plasma BNP concentrations should be interpreted with caution when assessing patients with VHD. PMID:27175283

  16. Automatic extraction of myocardial mass and volumes using parametric images from dynamic nongated PET

    DEFF Research Database (Denmark)

    Harms, Hendrik Johannes; Hansson, Nils Henrik Stubkjær; Tolbod, Lars Poulsen

    2016-01-01

    Dynamic cardiac positron emission tomography (PET) is used to quantify molecular processes in vivo. However, measurements of left-ventricular (LV) mass and volumes require electrocardiogram (ECG)-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using non......-gated dynamic cardiac PET. METHODS: Thirty-five patients with aortic-valve stenosis and 10 healthy controls (HC) underwent a 27-min 11C-acetate PET/CT scan and cardiac magnetic resonance imaging (CMR). HC were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were......LV and WT only and an overestimation for LVEF at lower values. Intra- and inter-observer correlations were >0.95 for all PET measurements. PET repeatability accuracy in HC was comparable to CMR. CONCLUSION: LV mass and volumes are accurately and automatically generated from dynamic 11C-acetate PET without...

  17. Efficacy of liver parenchymal enhancement and liver volume to standard liver volume ratio on Gd-EOB-DTPA-enhanced MRI for estimation of liver function

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Tomohide; Fukukura, Yoshihiko; Kamimura, Kiyohisa; Takumi, Koji; Umanodan, Aya; Nakajo, Masayuki [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Radiology, Kagoshima City (Japan); Ueno, Shinichi [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Surgical Oncology and Digestive Surgery, Kagoshima City (Japan)

    2014-04-15

    We aimed to develop and assess the efficacy of a liver function index that combines liver enhancement and liver volume to standard liver volume (LV/SLV) ratio on gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced MRI. In all, 111 patients underwent a Gd-EOB-DTPA-enhanced MRI, including T1 mapping, before and 20 min after Gd-EOB-DTPA administration. We calculated the following Gd-EOB-DTPA-enhanced MRI-based liver function indices: relative enhancement of the liver, corrected enhancement of the liver-to-spleen ratio, LSC{sub N}20, increase rate of the liver-to-muscle ratio, reduction rate of T1 relaxation time of the liver, ΔR1 of the liver and K{sub Hep}; the indices were multiplied by the LV/SLV ratio. We calculated the correlations between an indocyanine green (ICG) clearance and the Gd-EOB-DTPA-enhanced MRI-based liver function indices multiplied by the LV/SLV ratio, by using Pearson correlation analysis. There were significant correlations between all Gd-EOB-DTPA-enhanced MRI-based liver function indices and ICG clearance (r = -0.354 to -0.574, P < 0.001). All Gd-EOB-DTPA-enhanced MRI-based liver function indices multiplied by the LV/SLV ratio (r = -0.394 to -0.700, P < 0.001) were more strongly correlated with the ICG clearance than those without multiplication by the LV/SLV ratio. Gd-EOB-DTPA-enhanced MRI-based liver function indices that combine liver enhancement and the LV/SLV ratio may more reliably estimate liver function. (orig.)

  18. Influence of magnification on the calculated value of left ventricular ejection fraction and volumes using quantitative gated perfusion SPECT

    International Nuclear Information System (INIS)

    Nunez, M.; Beretta, M.; Alonso, O.; Alvarez, B.; Canepa, J.; Mut, F.

    2002-01-01

    Aim: To compare left ventricular ejection fraction (LVEF), end-diastolic volumes (EDV) and end-systolic volumes (ESV) measured by quantitative gated SPECT (QGSPECT) in studies acquired with and without magnification factor (zoom). Material and Methods: We studied 30 consecutive patients (17 men, ages 61±14 years) referred for myocardial perfusion evaluation with a 2-day protocol. Studies were performed after injection of 925 MBq (25 mCi) of 99mTc-MIBI in the resting state. Gated SPECT was first acquired using a x2 zoom factor and immediately repeated with x1 zoom (no magnification), using a 64x64 matrix and 8 frames/cardiac cycle. Patients with arrhythmia were not included in the investigation. According to the median EDV calculated with the x2 zoom acquisition, the population was further divided in two sub-groups regarding the size of the LV cavity. Average LVEF, EDV, ESV and difference between values (delta) were then calculated for the total population and for each sub-group (a and b). Results: For the total population, results are expressed.Pearson correlation showed r=0.954 between LVEF with and without zoom (p<0.0001), but linear regression analysis did not fit a specific model (p=0.18). Median EDV with zoom was 92.5 ml, allowing to separate 15 cases with EDV above (a) and 15 below that value (b). Results for both sub-groups are presented. Conclusion: Calculated LVEF is higher with no zoom, at the expense of decreasing both EDV and ESV. Although differences were very significant for all parameters, ESV changes were specially relevant with no zoom, particularly in patients with smaller hearts. Although good correlation was found between LVEF with and without zoom, no specific correction factor was found to convert one value into the other. Magnification factor should be kept constant in gated SPECT if calculated LVEF values QGSPECT are expected to be reliable, and validation of the method using different zoom factors should be considered

  19. Validity of predicting left ventricular end systolic pressure changes following an acute bout of exercise.

    Science.gov (United States)

    Kappus, Rebecca M; Ranadive, Sushant M; Yan, Huimin; Lane, Abbi D; Cook, Marc D; Hall, Grenita; Harvey, I Shevon; Wilund, Kenneth R; Woods, Jeffrey A; Fernhall, Bo

    2013-01-01

    Left ventricular end systolic pressure (LV ESP) is important in assessing left ventricular performance and is usually derived from prediction equations. It is unknown whether these equations are accurate at rest or following exercise in a young, healthy population. Measured LV ESP vs. LV ESP values from the prediction equations were compared at rest, 15 min and 30 min following peak aerobic exercise in 60 participants. LV ESP was obtained by applanation tonometry at rest, 15 min post and 30 min post peak cycle exercise. Measured LV ESP was significantly lower (p<0.05) at all time points in comparison to the two calculated values. Measured LV ESP decreased significantly from rest at both the post15 and post30 time points (p<0.05) and changed differently in comparison to the calculated values (significant interaction; p<0.05). The two LV ESP equations were also significantly different from each other (p<0.05) and changed differently over time (significant interaction; p<0.05). The two commonly used prediction equations did not accurately predict either resting or post exercise LV ESP in a young, healthy population. Thus, LV ESP needs to be individually determined in young, healthy participants. Non-invasive measurement through applanation tonometry appears to allow for a more accurate determination of LV ESP. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. Impact of bileaflet mitral valve prolapse on quantification of mitral regurgitation with cardiac magnetic resonance: a single-center study.

    Science.gov (United States)

    Vincenti, Gabriella; Masci, Pier Giorgio; Rutz, Tobias; De Blois, Jonathan; Prša, Milan; Jeanrenaud, Xavier; Schwitter, Juerg; Monney, Pierre

    2017-07-27

    To quantify mitral regurgitation (MR) with CMR, the regurgitant volume can be calculated as the difference between the left ventricular (LV) stroke volume (SV) measured with the Simpson's method and the reference SV, i.e. the right ventricular SV (RVSV) in patients without tricuspid regurgitation. However, for patients with prominent mitral valve prolapse (MVP), the Simpson's method may underestimate the LV end-systolic volume (LVESV) as it only considers the volume located between the apex and the mitral annulus, and neglects the ventricular volume that is displaced into the left atrium but contained within the prolapsed mitral leaflets at end systole. This may lead to an underestimation of LVESV, and resulting an over-estimation of LVSV, and an over-estimation of mitral regurgitation. The aim of the present study was to assess the impact of prominent MVP on MR quantification by CMR. In patients with MVP (and no more than trace tricuspid regurgitation) MR was quantified by calculating the regurgitant volume as the difference between LVSV and RVSV. LVSV uncorr was calculated conventionally as LV end-diastolic (LVEDV) minus LVESV. A corrected LVESV corr was calculated as the LVESV plus the prolapsed volume, i.e. the volume between the mitral annulus and the prolapsing mitral leaflets. The 2 methods were compared with respect to the MR grading. MR grades were defined as absent or trace, mild (5-29% regurgitant fraction (RF)), moderate (30-49% RF), or severe (≥50% RF). In 35 patients (44.0 ± 23.0y, 14 males, 20 patients with MR) the prolapsed volume was 16.5 ± 8.7 ml. The 2 methods were concordant in only 12 (34%) patients, as the uncorrected method indicated a 1-grade higher MR severity in 23 (66%) patients. For the uncorrected/corrected method, the distribution of the MR grades as absent-trace (0 vs 11, respectively), mild (20 vs 18, respectively), moderate (11 vs 5, respectively), and severe (4 vs 1, respectively) was significantly different (p

  1. Comparative efficacy of amiodarone with ivabradin combination or amiodarone with bisoprolol combination in the prevention of atrial fibrillation recurrence in pa- tients with left ventricular diastolic dysfunction

    Directory of Open Access Journals (Sweden)

    K. G. Adamyan

    2015-01-01

    Full Text Available Aim. To study the efficacy of use of amiodarone with ivabradine combination or amiodarone with bisoprolol combination in the prevention of atrial fibrillation (AF recurrence in patients (pts with left ventricular diastolic dysfunction (LVDD after conversion to sinus rhythm. Material and methods. 65 patients (40 males, 25 females aged 53±8 years with persistent AF and LVDD were included into the study and randomized into 3 groups to receive ivabradine and amiodarone (22 pts, bisoprolol and amiodarone (22 pts or amiodarone alone (21 pts. Left atrium (LA volume indices, LA longitudinal strain rate (LASR in systole, LV mass index, mean heart rate (HR, 24-hour HR variability and the incidence of AF by 96 h ECG monitoring were measured after the titration period, and after 3 and 6 months of follow-up. Results. After 6 months of follow-up group 1 revealed significantly lower maximum LA volume index (21.3±2.4 vs 25.2±3.0 and 28.7±3.6 ml/m2 in the 2nd and control groups, respectively, P-wave LA volume index (15.3±3.5 versus 18.1±3.8 and 20.4±4.0 ml/m2 in the 2nd and control groups, respectively, and LA systolic volume index (7.3±1.2 versus 9.4±1.6 and 9.6±1.7 ml/m2 in 2nd and control groups, respectively. The incidence of side effects in group 1 was significantly less than that in group 2 and was not different compared with control group. Conclusion. Ivabradine and amiodarone combination provides better prevention of AF recurrence and less side-effects in pts with LVDD and persistent AF after sinus rhythm restoration as compared with bisoprolol and amiodarone combination, it also reduces LA maximum, conduit and systolic volumes, and increases LASR.

  2. A Non-Dimensional Analysis of Cardiovascular Response to Cold Stress. Part I. Identification of the Physical Parameters that Govern the Thermoregulatory Function of the Cardiovascular System.

    Science.gov (United States)

    1983-09-01

    together with an increased ventricular distensibility , tend to raise the end - 66 - diastolic volume. Again, however, :he inadequace emptying tends to... Distensibility (Sympathetic Increase, Para- sympathetic Decrease); (xi) Atrial contraction (end diastolic volume), (enhanced by sympathetic stimulation...Relationships For Striated Skeletal Muscle; Part III, Mechanics and Energetics of Muscular Contraction," Virginia Polytechnic Institute and State

  3. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart disease; Wartosc angiokardiografii radioizotopowej dla oznaczania objetosci lewej komory u chorych z zastawkowymi wadami serca

    Energy Technology Data Exchange (ETDEWEB)

    Konieczna, S.; Madeja, G.; Gosiewska-Marcinkowska, E.; Szumilak, B.; Brodzki, L.M.; Leszek, P. [Instytut Kardiologii, Warsaw (Poland)

    1992-12-31

    The aim of this study was to investigate usability of the Massardo method in calculating the left ventricular volume in patients with valvular defect. The group consisted of 21 patients with mitral defect. Left ventricular volumes obtained by contrast ventriculography were used for reference. The correlation coefficient between these two methods was 0.94, SEE=29 ml, V{sub nucl}=0.94 V{sub c.vent}+11. The end-systolic and end-diastolic outlines were marked manually. We concluded that the Massardo methods is an effective method of calculating the left ventricular volume also in group of patients with mitral defect. (author). 11 refs, 4 tabs.

  4. Effect of prolonged space flight on cardiac function and dimensions

    Science.gov (United States)

    Henry, W. L.; Epstein, S. E.; Griffith, J. M.; Goldstein, R. E.; Redwood, D. R.

    1974-01-01

    Echocardiographic studies were performed preflight 5 days before launch and on recovery day and 1, 2, 4, 11, 31 and 68 days postflight. From these echocardiograms measurements were made. From these primary measurements, left ventricular end-diastolic volume, end-systolic volume, stroke volume, and mass were derived using the accepted assumptions. Findings in the Scientist Pilot and Pilot resemble those seen in trained distance runners. Wall thickness measurements were normal in all three crewmembers preflight. Postflight basal studies were unchanged in the Commander on recovery day through 68 days postflight in both the Scientist Pilot and Pilot, however, the left ventricular end-diastolic volume, stroke volume, and mass were decreased slightly. Left ventricular function curves were constructed for the Commander and Pilot by plotting stroke volume versus end-diastolic volume. In both astronauts, preflight and postflight data fell on the same straight line demonstrating that no deterioration in cardiac function had occurred. These data indicate that the cardiovascular system adapts well to prolonged weightlessness and suggest that alterations in cardiac dimensions and function are unlikely to limit man's future in space.

  5. New classification of geometric ventricular patterns in severe aortic stenosis: Could it be clinically useful?

    Science.gov (United States)

    Di Nora, Concetta; Cervesato, Eugenio; Cosei, Iulian; Ravasel, Andreea; Popescu, Bogdan A; Zito, Concetta; Carerj, Scipione; Antonini-Canterin, Francesco; Popescu, Andreea C

    2018-04-16

    In severe aortic stenosis, different left ventricle (LV) remodeling patterns as a response to pressure overload have distinct hemodynamic profiles, cardiac function, and outcomes. The most common classification considers LV relative wall thickness and LV mass index to create 4 different groups. A new classification including also end-diastolic volume index has been recently proposed. To describe the prevalence of the newly identified remodeling patterns in patients with severe aortic stenosis and to evaluate their clinical relevance according to symptoms. We analyzed 286 consecutive patients with isolated severe aortic stenosis. Current guidelines were used for echocardiographic evaluation. Symptoms were defined as the presence of angina, syncope, or NYHA class III-IV. The mean age was 75 ± 9 years, 156 patients (54%) were men, while 158 (55%) were symptomatic. According to the new classification, the most frequent remodeling pattern was concentric hypertrophy (57.3%), followed by mixed (18.9%) and dilated hypertrophy (8.4%). There were no patients with eccentric remodeling; only 4 patients had a normalLV geometry. Symptomatic patients showed significantly more mixed hypertrophy (P < .05), while the difference regarding the prevalence of the other patterns was not statistically significant. When we analyzed the distribution of the classic 4 patterns stratified by the presence of symptoms, however, we did not find a significant difference (P = .157). The new classification had refined the description of different cardiac geometric phenotypes that develop as a response to pressure overload. It might be superior to the classic 4 patterns in terms of association with symptoms. © 2018 Wiley Periodicals, Inc.

  6. Targeted Gene-Silencing Reveals the Functional Significance of Myocardin Signaling in the Failing Heart

    Science.gov (United States)

    Torrado, Mario; Iglesias, Raquel; Centeno, Alberto; López, Eduardo; Mikhailov, Alexander T.

    2011-01-01

    Background Myocardin (MYOCD), a potent transcriptional coactivator of smooth muscle (SM) and cardiac genes, is upregulated in failing myocardium in animal models and human end-stage heart failure (HF). However, the molecular and functional consequences of myocd upregulation in HF are still unclear. Methodology/Principal Findings The goal of the present study was to investigate if targeted inhibition of upregulated expression of myocd could influence failing heart gene expression and function. To this end, we used the doxorubicin (Dox)-induced diastolic HF (DHF) model in neonatal piglets, in which, as we show, not only myocd but also myocd-dependent SM-marker genes are highly activated in failing left ventricular (LV) myocardium. In this model, intra-myocardial delivery of short-hairpin RNAs, designed to target myocd variants expressed in porcine heart, leads on day 2 post-delivery to: (1) a decrease in the activated expression of myocd and myocd-dependent SM-marker genes in failing myocardium to levels seen in healthy control animals, (2) amelioration of impaired diastolic dysfunction, and (3) higher survival rates of DHF piglets. The posterior restoration of elevated myocd expression (on day 7 post-delivery) led to overexpression of myocd-dependent SM-marker genes in failing LV-myocardium that was associated with a return to altered diastolic function. Conclusions/Significance These data provide the first evidence that a moderate inhibition (e.g., normalization) of the activated MYOCD signaling in the diseased heart may be promising from a therapeutic point of view. PMID:22028870

  7. Targeted gene-silencing reveals the functional significance of myocardin signaling in the failing heart.

    Directory of Open Access Journals (Sweden)

    Mario Torrado

    Full Text Available BACKGROUND: Myocardin (MYOCD, a potent transcriptional coactivator of smooth muscle (SM and cardiac genes, is upregulated in failing myocardium in animal models and human end-stage heart failure (HF. However, the molecular and functional consequences of myocd upregulation in HF are still unclear. METHODOLOGY/PRINCIPAL FINDINGS: The goal of the present study was to investigate if targeted inhibition of upregulated expression of myocd could influence failing heart gene expression and function. To this end, we used the doxorubicin (Dox-induced diastolic HF (DHF model in neonatal piglets, in which, as we show, not only myocd but also myocd-dependent SM-marker genes are highly activated in failing left ventricular (LV myocardium. In this model, intra-myocardial delivery of short-hairpin RNAs, designed to target myocd variants expressed in porcine heart, leads on day 2 post-delivery to: (1 a decrease in the activated expression of myocd and myocd-dependent SM-marker genes in failing myocardium to levels seen in healthy control animals, (2 amelioration of impaired diastolic dysfunction, and (3 higher survival rates of DHF piglets. The posterior restoration of elevated myocd expression (on day 7 post-delivery led to overexpression of myocd-dependent SM-marker genes in failing LV-myocardium that was associated with a return to altered diastolic function. CONCLUSIONS/SIGNIFICANCE: These data provide the first evidence that a moderate inhibition (e.g., normalization of the activated MYOCD signaling in the diseased heart may be promising from a therapeutic point of view.

  8. Path integral for stochastic inflation: Nonperturbative volume weighting, complex histories, initial conditions, and the end of inflation

    Science.gov (United States)

    Gratton, Steven

    2011-09-01

    In this paper we present a path integral formulation of stochastic inflation. Volume weighting can be naturally implemented from this new perspective in a very straightforward way when compared to conventional Langevin approaches. With an in-depth study of inflation in a quartic potential, we investigate how the inflaton evolves and how inflation typically ends both with and without volume weighting. The calculation can be carried to times beyond those accessible to conventional Fokker-Planck approaches. Perhaps unexpectedly, complex histories sometimes emerge with volume weighting. The reward for this excursion into the complex plane is an insight into how volume-weighted inflation both loses memory of initial conditions and ends via slow roll. The slow-roll end of inflation mitigates certain “Youngness Paradox”-type criticisms of the volume-weighted paradigm. Thus it is perhaps time to rehabilitate proper-time volume weighting as a viable measure for answering at least some interesting cosmological questions.

  9. Path integral for stochastic inflation: Nonperturbative volume weighting, complex histories, initial conditions, and the end of inflation

    International Nuclear Information System (INIS)

    Gratton, Steven

    2011-01-01

    In this paper we present a path integral formulation of stochastic inflation. Volume weighting can be naturally implemented from this new perspective in a very straightforward way when compared to conventional Langevin approaches. With an in-depth study of inflation in a quartic potential, we investigate how the inflaton evolves and how inflation typically ends both with and without volume weighting. The calculation can be carried to times beyond those accessible to conventional Fokker-Planck approaches. Perhaps unexpectedly, complex histories sometimes emerge with volume weighting. The reward for this excursion into the complex plane is an insight into how volume-weighted inflation both loses memory of initial conditions and ends via slow roll. The slow-roll end of inflation mitigates certain ''Youngness Paradox''-type criticisms of the volume-weighted paradigm. Thus it is perhaps time to rehabilitate proper-time volume weighting as a viable measure for answering at least some interesting cosmological questions.

  10. Advanced Age Attenuates Left Ventricular Filling Efficiency Quantified Using Vortex Formation Time: A Study of Octogenarians With Normal Left Ventricular Systolic Function Undergoing Coronary Artery Surgery.

    Science.gov (United States)

    Pagel, Paul S; Dye, Lonnie; Boettcher, Brent T; Freed, Julie K

    2018-03-07

    Blood flow across the mitral valve during early left ventricular (LV) filling produces a 3-dimensional rotational fluid body, known as a vortex ring, that enhances LV filling efficiency. Diastolic dysfunction is common in elderly patients, but the influence of advanced age on vortex formation is unknown. The authors tested the hypothesis that advanced age is associated with a reduction in LV filling efficiency quantified using vortex formation time (VFT) in octogenarians undergoing coronary artery bypass graft (CABG) surgery. Observational study. Veterans Affairs medical center. After institutional review board approval, octogenarians (n = 7; 82 ± 2 year [mean ± standard deviation]; ejection fraction 56% ± 7%) without valve disease or atrial arrhythmias undergoing CABG were compared with a younger cohort (n = 7; 55 ± 6 year; ejection fraction 57% ± 7%) who were undergoing coronary revascularization. None. All patients were monitored using radial and pulmonary arterial catheters and transesophageal echocardiography. Peak early LV filling (E) and atrial systole (A) blood flow velocities and their corresponding velocity-time integrals were obtained using pulse-wave Doppler echocardiography to determine E/A, atrial filling fraction (β), and E wave deceleration time. Pulse-wave Doppler also was used to measure pulmonary venous blood flow during systole and diastole. Mitral valve diameter (D) was calculated as the average of major and minor axis lengths obtained in the midesophageal LV bicommissural and long-axis transesophageal echocardiography imaging planes, respectively. VFT was calculated as 4 × (1 - β) × SV/(πD 3 ), where SV is the stroke volume measured using thermodilution. Systemic and pulmonary hemodynamics, LV diastolic function, and VFT were determined during steady-state conditions 30 minutes before cardiopulmonary bypass. A delayed relaxation pattern of LV filling (E/A 0.81 ± 0.16 v 1.29 ± 0.19, p = 0.00015; β 0.44 ± 0.05 v 0.35 ± 0.03, p = 0

  11. Early Diastolic Strain Rate in Relation to Systolic and Diastolic Function and Prognosis in Aortic Stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Barros-Gomes, Sergio; Videbæk, Lars

    2016-01-01

    OBJECTIVES: This study examined the impact of early mitral inflow velocity-to-early diastolic strain rate (E/SRe) ratio on long-term outcome after aortic valve replacement (AVR) in aortic stenosis (AS). BACKGROUND: In AS, increased filling pressures are associated with a poor prognosis and can...... be estimated using the early diastolic mitral inflow velocity-to-early diastolic velocity of the mitral annulus (E/e') ratio. Recent studies suggest that the E/SRe ratio surpasses the E/e' ratio in estimating outcome. METHODS: Pre-operative evaluation was performed in 121 patients with severe AS (aortic valve...... area 40% who were scheduled for AVR. Patients were divided according to E/SRe median and followed for 5 years. The primary endpoint was overall mortality. RESULTS: LVEF was lower (53 ± 7% vs. 56 ± 7%, respectively; p = 0.03) and a restrictive...

  12. The importance of integrated left atrial evaluation: From hypertension to heart failure with preserved ejection fraction.

    Science.gov (United States)

    Beltrami, Matteo; Palazzuoli, Alberto; Padeletti, Luigi; Cerbai, Elisabetta; Coiro, Stefano; Emdin, Michele; Marcucci, Rossella; Morrone, Doralisa; Cameli, Matteo; Savino, Ketty; Pedrinelli, Roberto; Ambrosio, Giuseppe

    2018-02-01

    Functional analysis and measurement of left atrium are an integral part of cardiac evaluation, and they represent a key element during non-invasive analysis of diastolic function in patients with hypertension (HT) and/or heart failure with preserved ejection fraction (HFpEF). However, diastolic dysfunction remains quite elusive regarding classification, and atrial size and function are two key factors for left ventricular (LV) filling evaluation. Chronic left atrial (LA) remodelling is the final step of chronic intra-cavitary pressure overload, and it accompanies increased neurohormonal, proarrhythmic and prothrombotic activities. In this systematic review, we aim to purpose a multi-modality approach for LA geometry and function analysis, which integrates diastolic flow with LA characteristics and remodelling through application of both traditional and new diagnostic tools. The most important studies published in the literature on LA size, function and diastolic dysfunction in patients with HFpEF, HT and/or atrial fibrillation (AF) are considered and discussed. In HFpEF and HT, pulsed and tissue Doppler assessments are useful tools to estimate LV filling pressure, atrio-ventricular coupling and LV relaxation but they need to be enriched with LA evaluation in terms of morphology and function. An integrated evaluation should be also applied to patients with a high arrhythmic risk, in whom eccentric LA remodelling and higher LA stiffness are associated with a greater AF risk. Evaluation of LA size, volume, function and structure are mandatory in the management of patients with HT, HFpEF and AF. A multi-modality approach could provide additional information, identifying subjects with more severe LA remodelling. Left atrium assessment deserves an accurate study inside the cardiac imaging approach and optimised measurement with established cut-offs need to be better recognised through multicenter studies. © 2017 John Wiley & Sons Ltd.

  13. Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Yuzo; Yonezawa, Masato; Matsuo, Yoshio; Kamitani, Takeshi; Higuchi, Ko; Honda, Hiroshi [Graduate School of Medical Sciences, Kyushu University, Department of Clinical Radiology, Higashi-ku, Fukuoka (Japan); Nagao, Michinobu; Kawanami, Satoshi [Graduate School of Medical Sciences, Kyushu University, Department of Molecular Imaging and Diagnosis, Higashi-ku, Fukuoka (Japan); Yamamura, Kenichiro [Graduate School of Medical Sciences, Kyushu University, Department of Pediatrics, Higashi-ku, Fukuoka (Japan); Sakamoto, Ichiro [Graduate School of Medical Sciences, Kyushu University, Department of Cardiovascular Medicine, Higashi-ku, Fukuoka (Japan); Shiokawa, Yuichi [Graduate School of Medical Sciences, Kyushu University, Department of Cardiovascular Surgery, Higashi-ku, Fukuoka (Japan); Yabuuchi, Hidetake [Graduate School of Medical Sciences, Kyushu University, Department of Health Sciences, Higashi-ku, Fukuoka (Japan)

    2014-12-15

    To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0 %) and PRF (-9.1 ± 2.0 %) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. (orig.)

  14. Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI

    International Nuclear Information System (INIS)

    Yamasaki, Yuzo; Yonezawa, Masato; Matsuo, Yoshio; Kamitani, Takeshi; Higuchi, Ko; Honda, Hiroshi; Nagao, Michinobu; Kawanami, Satoshi; Yamamura, Kenichiro; Sakamoto, Ichiro; Shiokawa, Yuichi; Yabuuchi, Hidetake

    2014-01-01

    To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0 %) and PRF (-9.1 ± 2.0 %) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. (orig.)

  15. Association Between Epicardial Fat Thickness and Premature Coronary Artery Disease: A Case Control Study

    Science.gov (United States)

    Faghihi, Shadi; Vasheghani-Farahani, Ali; Parsaee, Mozhgan; Saedi, Sedigheh; Ghadrdoost, Behshid

    2015-01-01

    Background: The association between epicardial fat thickness (EFT) and premature coronary artery disease (CAD) has not been elaborately studied. Objectives: In the present study, we sought whether such a relationship between EFT and CAD exists. Patients and Methods: Sixty two consecutive subjects, under 50 years of age, who underwent coronary angiography (CAG) with the aspect of CAD, were included in this case control study. They were divided into two groups of 31 subjects, namely CAD (cases) and non-CAD (controls) group, according to CAG data. Presence of conventional coronary risk factors, drug history, and anthropometric data were recorded. Then, each subject underwent standard transthoracic echocardiography for measuring EFT in the proximal part of right ventricular outflow tract in the parasternal long axis view at end diastole, as well as other parameters of systolic and diastolic function, and left ventricle (LV) mass. Images were stored for offline analysis when the echocardiocardiographers were blind to CAG data. Results: Among baseline characteristics, waist circumference, triglyceride levels, cigarette smoking and history of statin use were significantly higher in the CAD group. The body mass index (BMI) was significantly higher in the non-CAD group. According to echocardiographic data, the EFT with a cut off value of 2.95 mm could well differentiate subjects in each group. The LV mass and E/e were significantly higher in CAD group, in addition to EFT. Also, there was a significant correlation between EFT and waist circumference, as well as LV mass. However, no significant relation was between EFT and LV systolic and diastolic function. Conclusions: The EFT, as measured by echocardiography, with a cut off value 2.95 mm has a strong association with premature CAD. PMID:26380819

  16. The surface glycoprotein of a natural feline leukemia virus subgroup A variant, FeLV-945, as a determinant of disease outcome.

    Science.gov (United States)

    Bolin, Lisa L; Ahmad, Shamim; Levy, Laura S

    2011-10-15

    Feline leukemia virus (FeLV) is a natural retrovirus of domestic cats associated with degenerative, proliferative and malignant diseases. Studies of FeLV infection in a cohort of naturally infected cats were undertaken to examine FeLV variation, the selective pressures operative in FeLV infection that lead to predominance of natural variants, and the consequences for infection and disease progression. A unique variant, designated FeLV-945, was identified as the predominant isolate in the cohort and was associated with non-T-cell diseases including multicentric lymphoma. FeLV-945 was assigned to the FeLV-A subgroup based on sequence analysis and receptor utilization, but was shown to differ in sequence from a prototype member of FeLV-A, designated FeLV-A/61E, in the long terminal repeat (LTR) and the surface glycoprotein gene (SU). A unique sequence motif in the FeLV-945 LTR was shown to function as a transcriptional enhancer and to confer a replicative advantage. The FeLV-945 SU protein was observed to differ in sequence as compared to FeLV-A/61E within functional domains known to determine receptor selection and binding. Experimental infection of newborn cats was performed using wild type FeLV-A/61E or recombinant FeLV-A/61E in which the LTR (61E/945L) or LTR and SU (61E/945SL) were exchanged for that of FeLV-945. Infection with either FeLV-A/61E or 61E/945L resulted in T-cell lymphoma of the thymus, although 61E/945L caused disease significantly more rapidly. In contrast, infection with 61E/945SL resulted in the rapid induction of a multicentric lymphoma of B-cell origin, thus recapitulating the outcome of natural infection and implicating FeLV-945 SU as a determinant of disease outcome. Recombinant FeLV-B was detected infrequently and at low levels in multicentric lymphomas, and was thereby not implicated in disease induction. Preliminary studies of receptor interaction indicated that virus particles bearing FeLV-945 SU bind to the FeLV-A receptor more

  17. The impact of preload reduction with head-up tilt testing on longitudinal and transverse left ventricular mechanics: a study utilizing deformation volume analysis.

    Science.gov (United States)

    Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith; Oxborough, David

    2018-03-01

    Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function; however, the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume loops (deformation volume analysis - DVA). There was a leftward shift of the ε-volume loop from supine to 1 min and 5 min of HUT ( P  transverse thickening from supine to 1 min, which was further augmented at 5 min ( P  = 0.018). Preload reduction occurs within 1 min of HUT but does not further reduce at 5 min. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. © 2018 The authors.

  18. Protection of LV system against lightning

    OpenAIRE

    Yordanova Nedyalkova, Greta

    2010-01-01

    Lightning is a natural hazard and one of the greatest local mysteries. Scientists have not fully understood the mechanism of lightning. It is one of the most beautiful displays in nature and one of the nature's most dangerous phenomenon known to man. Overvoltage due to lightning is a very important problem of LV systems. Some lightning flashes damage buildings and a few kill or injure people and animals, either directly or indirectly, by causing fire and explosions. The need for protect...

  19. Cholinergic depletion and basal forebrain volume in primary progressive aphasia

    Directory of Open Access Journals (Sweden)

    Jolien Schaeverbeke

    2017-01-01

    In the PPA group, only LV cases showed decreases in AChE activity levels compared to controls. Surprisingly, a substantial number of SV cases showed significant AChE activity increases compared to controls. BF volume did not correlate with AChE activity levels in PPA. To conclude, in our sample of PPA patients, LV but not SV was associated with cholinergic depletion. BF atrophy in PPA does not imply cholinergic depletion.

  20. Two dimensional polar display of cardiac blood pool SPECT

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Mamiya, Toshio; Takahashi, Taku; Takishima, Teruo; Hasegawa, Noriko; Hashimoto, Masanori; Ohno, Ken

    1989-01-01

    A new method of ECG gated cardiac blood pool SPECT to illustrate the left ventricular (LV) wall motion in a single static image, two dimensional polar display (2DPD), was described. Circumferential profiles of the difference between end diastolic and end systolic short axis images of the LV were displayed in a similar way to the bull's eye plot of 201 Tl myocardial SPECT. The diagnoses by 2DPDs agreed with those by cinematic displays of ECG gated blood pool SPECT in 74 out of 84 segments (85.5%) of abnormal motion, and 155 out of 168 segments (80.3%) of normal motion. It is concluded that 2DPD can evaluate regional wall motion by a single static image in a significant number of patients, and is also useful in comparing with the bull's eye image of 201 Tl myorcardial SPECT. (orig.)