WorldWideScience

Sample records for lung vascular leakage

  1. Synergism between endotoxin priming and exotoxin challenge in provoking severe vascular leakage in rabbit lungs.

    Science.gov (United States)

    Schütte, H; Rosseau, S; Czymek, R; Ermert, L; Walmrath, D; Krämer, H J; Seeger, W; Grimminger, F

    1997-09-01

    Lipopolysaccharides (LPS) of gram-negative bacteria prime rabbit lungs for enhanced thromboxane-mediated vasoconstriction upon subsequent challenge with the exotoxin Escherichia coli hemolysin (HlyA) (Walmrath et al. J. Exp. Med. 1994;180:1437-1443). We investigated the impact of endotoxin priming and subsequent HlyA challenge on lung vascular permeability while maintaining constancy of capillary pressure. Rabbit lungs were perfused in a pressure-controlled mode in the presence of the thromboxane receptor antagonist BM 13.505, with continuous monitoring of flow. Perfusion for 180 min with 10 ng/ml LPS did not provoke vasoconstriction or alteration of capillary filtration coefficient (Kfc) values. HlyA (0.021 hemolytic units/ml) induced thromboxane release and a transient decrease in perfusion flow in the absence of significant changes in Kfc. Similar results were obtained when LPS and HlyA were coapplied simultaneously. However, when the HlyA challenge was undertaken after 180 min of LPS priming, a manifold increase in Kfc values was noted, with concomitant severe lung edema formation, although capillary pressure remained unchanged. Thus, endotoxin primes the lung vasculature to respond with a severe increase in vascular permeability to a subsequent low-dose application of HlyA. Such synergism between endotoxin priming and exotoxin challenge in provoking lung vascular leakage may contribute to the pathogenesis of respiratory failure in sepsis and severe lung infection.

  2. Aerosolized PGE1, PGI2 and nitroprusside protect against vascular leakage in lung ischaemia-reperfusion.

    Science.gov (United States)

    Schütte, H; Löckinger, A; Seeger, W; Grimminger, F

    2001-07-01

    High permeability oedema is an important feature in lung injury secondary to ischaemia-reperfusion. This study investigated the influence of aerosolized prostaglandin E1 (PGE1), prostaglandin I2 (PCI2) and the nitric oxide (NO)-donor, sodium nitroprusside (SNP) on microvascular barrier function in pulmonary ischaemia-reperfusion. Buffer-perfused rabbit lungs were exposed to 180 or 210 min of warm ischaemia while maintaining anoxic ventilation and a positive intravascular pressure. Reperfusion provoked a transient, mostly precapillary elevation of vascular resistance, followed by a severe increase of the capillary filtration coefficient (Kfc) versus nonischaemic controls (3.17+/-0.34 versus 0.85+/-0.05 cm3 x s(-1) cmH2O(-1) x g(-1) x 10(-4) after 30 min of reperfusion), and progressive oedema formation. Short-term aerosolization of SNP, PGE1 or PGI2 at the beginning of ischaemia largely suppressed the Kfc increase (1.36+/-0.22, 1.32+/-0.23 and 1.32+/-0.22 cm3 x s(-1) x cmH2O(-1) x g(-1) x 10(-4), respectively) and oedema formation. In contrast, application prior to reperfusion was much less effective, with some reduction of Kfc increase by PGI2 and SNP and no effect of PGE, (1.79+/-0.31, 2.2+/-0.53 and 3.2+/-0.05 cm3 x s(-1) x cmH2O(-1) x g(-1) x 10(-4), respectively). Haemodynamics, including microvascular pressure, were only marginally affected by the chosen doses of aerosolized vasodilators. It is concluded that short-term aerosolization of prostaglandin E1, prostaglandin I2 and sodium nitroprusside at the onset of ischaemia is highly effective in maintaining endothelial barrier properties in pulmonary ischaemia-reperfusion. This effect is apparently attributable to nonvasodilatory mechanisms exerted by these agents. Alveolar deposition of prostaglandins and/or nitric oxide donors by the aerosol technique may offer pulmonary protection in ischaemia-reperfusion injury.

  3. Hemolysis-induced Lung Vascular Leakage Contributes to the Development of Pulmonary Hypertension.

    Science.gov (United States)

    Rafikova, Olga; Williams, Elissa R; McBride, Matthew L; Zemskova, Marina; Srivastava, Anup; Nair, Vineet; Desai, Ankit A; Langlais, Paul R; Zemskov, Evgeny; Simon, Marc; Mandarino, Lawrence J; Rafikov, Ruslan

    2018-04-13

    While hemolytic anemia-associated pulmonary hypertension (PH) and pulmonary arterial hypertension (PAH) are more common than the prevalence of idiopathic PAH alone, the role of hemolysis in the development of PAH is poorly characterized. We hypothesized that hemolysis independently contributes to PAH pathogenesis via endothelial barrier dysfunction with resulting perivascular edema and inflammation. Plasma samples from patients with and without PAH (both confirmed by right heart catheterization) were used to measure free hemoglobin (Hb) and its correlation with PAH severity. A sugen(50mg/kg)/hypoxia(3wks)/normoxia(2wks) rat model was used to elucidate the role of free Hb/heme pathways in PAH. Human lung microvascular endothelial cells (HLMVECs) were utilized to study heme-mediated endothelial barrier effects. Our data indicate that PAH patients have increased levels of free Hb in plasma that correlate with PAH severity. There is also a significant accumulation of free Hb and depletion of haptoglobin in the rat model. In rats, perivascular edema was observed at early time points concomitant with increased infiltration of inflammatory cells. Heme-induced endothelial permeability in HLMVECs involved activation of the p38/HSP27 pathway. Indeed, the rat model also exhibited increased activation of p38/HSP27 during the initial phase of PH. Surprisingly, despite the increased levels of hemolysis and heme-mediated signaling, there was no heme oxygenase-1 activation. This can be explained by observed destabilization of HIF1a during the first two weeks of PH regardless of hypoxic conditions. Our data suggest that hemolysis may play a significant role in PAH pathobiology.

  4. Impact of arachidonic versus eicosapentaenoic acid on exotonin-induced lung vascular leakage: relation to 4-series versus 5-series leukotriene generation.

    Science.gov (United States)

    Grimminger, F; Wahn, H; Mayer, K; Kiss, L; Walmrath, D; Seeger, W

    1997-02-01

    Escherichia coli hemolysin (HlyA) is a proteinaceous pore-forming exotoxin that is implicated as a significant pathogenicity factor in extraintestinal E. coli infections including sepsis. In perfused rabbit lungs, subcytolytic concentrations of the toxin evoke thromboxane-mediated vasoconstriction and prostanoid-independent protracted vascular permeability increase (11). In the present study, the influence of submicromolar concentrations of free arachidonic acid (AA) and eicosapentaenoic acid (EPA) on the HlyA-induced leakage response was investigated. HlyA at concentration from 0.02 to 0.06 hemolytic units/ml provoked a dose-dependent, severalfold increase in the capillary filtration coefficient (Kfc), accompanied by the release of leukotriene(LT)B4, LTC4, and LTE4 into the recirculating buffer fluid. Simultaneous application of 100 nmol/L AA markedly augmented the HlyA-elicited leakage response, concomitant with an amplification of LTB4 release and a change in the kinetics of cysteinyl-LT generation. In contrast, 50 to 200 nmol/L EPA suppressed in a dose-dependent manner the HlyA-induced increase in Kfc values. This was accompanied by a blockage of 4-series LT generation and a dose-dependent appearance of LTB5, LTC5, and LTE5. In addition, EPA fully antagonized the AA-induced amplification of the HlyA-provoked Kfc increase, again accompanied by a shift from 4-series to 5-series LT generation. We conclude that the vascular leakage provoked by HlyA in rabbit lungs is differentially influenced by free AA versus free EPA, related to the generation of 4- versus 5-series leukotrienes. The composition of lipid emulsions used for parenteral nutrition may thus influence inflammatory capillary leakage.

  5. Macrophage migration inhibitory factor induces vascular leakage via autophagy

    Directory of Open Access Journals (Sweden)

    Hong-Ru Chen

    2015-01-01

    Full Text Available Vascular leakage is an important feature of acute inflammatory shock, which currently has no effective treatment. Macrophage migration inhibitory factor (MIF is a pro-inflammatory cytokine that can induce vascular leakage and plays an important role in the pathogenesis of shock. However, the mechanism of MIF-induced vascular leakage is still unclear. In this study, using recombinant MIF (rMIF, we demonstrated that MIF induced disorganization and degradation of junction proteins and increased the permeability of human endothelial cells in vitro. Western blotting analysis showed that rMIF treatment induced LC3 conversion and p62 degradation. Inhibition of autophagy with a PI3K inhibitor (3-MA, a ROS scavenger (NAC or autophagosomal-lysosomal fusion inhibitors (bafilomycin A1 and chloroquine rescued rMIF-induced vascular leakage, suggesting that autophagy mediates MIF-induced vascular leakage. The potential involvement of other signaling pathways was also studied using different inhibitors, and the results suggested that MIF-induced vascular leakage may occur through the ERK pathway. In conclusion, we showed that MIF triggered autophagic degradation of endothelial cells, resulting in vascular leakage. Inhibition of MIF-induced autophagy may provide therapeutic targets against vascular leakage in inflammatory shock.

  6. Lung protein leakage in feline septic shock.

    Science.gov (United States)

    Schützer, K M; Larsson, A; Risberg, B; Falk, A

    1993-06-01

    The aim of the present study was to explore lung microvascular leakage of protein and water in a feline model of septic shock, using a double isotope technique with external gamma camera detection and gravimetric lung water measurements. The experiments were performed on artificially ventilated cats. One group of cats (n = 8) was given an infusion of live Escherichia coli bacteria, and another group (n = 5) served as a control group receiving saline. Plasma transferrin was radiolabeled in vivo with indium-113m-chloride, and erythrocytes were labeled with technetium-99m. The distribution of these isotopes in the lungs was continuously measured with a gamma camera. A normalized slope index (NSI) was calculated, indicative of the transferrin accumulation corrected for changes in local blood volume that reflect protein leakage. In the septic group there was a protein leakage after bacterial infusion, with a NSI of 39 x 10(-4) +/- 5 x 10(-4) min-1 (mean +/- SEM), and the PaO2 diminished from 21 +/- 1 to 9.5 +/- 1 kPa. In control cats a slight protein leakage with a NSI of 9 +/- 10(-4) +/- 2 x 10(-4) min-1 was detected, probably caused by the operative procedure, but PaO2 did not change. Wet-to-dry-weight ratios of postmortem lungs were not significantly different between the groups. It was concluded that an intravenous infusion of live E. coli bacteria induces a lung capillary protein leakage without increased lung water and a concomitantly disturbed gas exchange.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Microvascular dysfunction with increased vascular leakage response in mice systemically exposed to arsenic.

    Science.gov (United States)

    Chen, Shih-Chieh; Huang, Shin-Yin; Lu, Chi-Yu; Hsu, Ya-Hung; Wang, Dean-Chuan

    2014-09-01

    The mechanisms underlying cardiovascular disease induced by arsenic exposure are not completely understood. The objectives of this study were to investigate whether arsenic-fed mice have an increased vascular leakage response to vasoactive agents and whether enhanced type-2 protein phosphatase (PP2A) activity is involved in mustard oil-induced leakage. ICR mice were fed water or sodium arsenite (20 mg/kg) for 4 or 8 weeks. The leakage response to vasoactive agents was quantified using the Evans blue (EB) technique or vascular labeling with carbon particles. Increased EB leakage and high density of carbon-labeled microvessels were detected in arsenic-fed mice treated with mustard oil. Histamine induced significantly higher vascular leakage in arsenic-fed mice than in water-fed mice. Pretreatment with the PP2A inhibitor okadaic acid or the neurokinin 1 receptor (NK1R) blocker RP67580 significantly reduced mustard oil-induced vascular leakage in arsenic-fed mice. The protein levels of PP2Ac and NK1R were similar in both groups. PP2A activity was significantly higher in the arsenic-fed mice compared with the control group. These findings indicate that microvessels generally respond to vasoactive agents, and that the increased PP2A activity is involved in mustard oil-induced vascular leakage in arsenic-fed mice. Arsenic may initiate endothelial dysfunction, resulting in vascular leakage in response to vasoactive agents.

  8. Transcytosis Involvement in Transport System and Endothelial Permeability of Vascular Leakage during Dengue Virus Infection

    Directory of Open Access Journals (Sweden)

    Chanettee Chanthick

    2018-02-01

    Full Text Available The major role of endothelial cells is to maintain homeostasis of vascular permeability and to preserve the integrity of vascular vessels to prevent fluid leakage. Properly functioning endothelial cells promote physiological balance and stability for blood circulation and fluid components. A monolayer of endothelial cells has the ability to regulate paracellular and transcellular pathways for transport proteins, solutes, and fluid. In addition to the paracellular pathway, the transcellular pathway is another route of endothelial permeability that mediates vascular permeability under physiologic conditions. The transcellular pathway was found to be associated with an assortment of disease pathogeneses. The clinical manifestation of severe dengue infection in humans is vascular leakage and hemorrhagic diatheses. This review explores and describes the transcellular pathway, which is an alternate route of vascular permeability during dengue infection that corresponds with the pathologic finding of intact tight junction. This pathway may be the route of albumin transport that causes endothelial dysfunction during dengue virus infection.

  9. Vascular injury in lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Tucker, A D; Wyatt, J H; Barry, J M; Undery, D

    1975-10-01

    Inhaled particulates which stimulate a 'delayed', cellular mode of alveolar clearance are excreted to the airways through lymphoid foci in the bronchial bifurcations. The anatomic relations and developing pathology of the tissues adjacent to these foci, including the divisions of accompanying arteries, were studied by serial sectioning and photomicrographic modelling of rat lungs. The changes are typical of classic 'delayed' inflammatory reactions and, in the rat, the fully developed stage is characterised by fibrinoid necrosis involving all three layers of the arterial wall in a linear lesion across the leading edge of the flow divider. An hypothesis was developed to relate the injury to pulsatile forces. Recent published findings indicate that similarly placed lesions, with species-specific changes in development, are universal in both cerebral and extra-cranial arterial forks of man and animals. Possible associations of the microvascular changes with human atherosclerosis and their further significance in pulmonary and systemic effects arising from industrial and environmental contaminants are explored.

  10. Vascular injury in lung disease

    International Nuclear Information System (INIS)

    Tucker, A.D.; Wyatt, J.H.; Barry, J.M.; Undery, Dawn.

    1975-10-01

    Inhaled particulates which stimulate a 'delayed', cellular mode of alveolar clearance are excreted to the airways through lymphoid foci in the bronchial bifurcations. The anatomic relations and developing pathology of the tissues adjacent to these foci, including the divisions of accompanying arteries, were studied by serial sectioning and photomicrographic modelling of rat lungs. The changes are typical of classic 'delayed' inflammatory reactions and, in the rat, the fully developed stage is characterised by fibrinoid necrosis involving all three layers of the arterial wall in a linear lesion across the leading edge of the flow divider. An hypothesis was developed to relate the injury to pulsatile forces. Recent published findings indicate that similarly placed lesions, with species-specific changes in development, are universal in both cerebral and extra-cranial arterial forks of man and animals. Possible associations of the microvascular changes with human atherosclerosis and their further significance in pulmonary and systemic effects arising from industrial and environmental contaminants are explored. (author)

  11. Longitudinal visualization of vascular occlusion, reperfusion, and remodeling in a zebrafish model of retinal vascular leakage using OCT angiography

    Science.gov (United States)

    Spitz, Kathleen; Bozic, Ivan; Desai, Vineet; Rao, Gopikrishna M.; Pollock, Lana M.; Anand-Apte, Bela; Tao, Yuankai K.

    2017-02-01

    Diabetic retinopathy (DR) and age-related macular degeneration (AMD) are two of the leading causes of blindness and visual impairment in the world. Neovascularization results in severe vision loss in DR and AMD and, thus, there is an unmet need to identify mechanisms of pathogenesis and novel anti-angiogenic therapies. Zebrafish is a leading model organism for studying human disease pathogenesis, and the highly conserved drug activity between zebrafish and humans and their ability to readily absorb small molecules dissolved in water has benefited pharmaceutical discovery. Here, we use optical coherence tomography (OCT) and OCT angiography (OCT-A) to perform noninvasive, in vivo retinal imaging in a zebrafish model of vascular leakage. Zebrafish were treated with diethylaminobenzaldehyde (DEAB) to induce vascular leakage and imaged with OCT and OCT-A at six time points over two weeks: baseline one day before treatment and one, three, six, eight, and ten days post treatment. Longitudinal functional imaging showed significant vascular response immediately after DEAB treatment. Observed vascular changes included partial or complete vascular occlusion immediately after treatment and reperfusion during a two-week period. Increased vascular tortuosity several days post treatment indicated remodeling, and bifurcations and collateral vessel formation were also observed. In addition, significant treatment response variabilities were observed in the contralateral eye of the same animal. Anatomical and functional normalization was observed in most animals by ten days post treatment. These preliminary results motivate potential applications of OCT-A as a tool for studying pathogenesis and therapeutic screening in zebrafish models of retinal vascular disease.

  12. Angiogenin and vascular endothelial growth factor expression in lungs of lung cancer patients.

    Science.gov (United States)

    Rozman, Ales; Silar, Mira; Kosnik, Mitja

    2012-12-01

    BACKGROUND.: Lung cancer is the leading cause of cancer deaths. Angiogenesis is crucial process in cancer growth and progression. This prospective study evaluated expression of two central regulatory molecules: angiogenin and vascular endothelial growth factor (VEGF) in patients with lung cancer. PATIENTS AND METHODS.: Clinical data, blood samples and broncho-alveolar lavage (BAL) from 23 patients with primary lung carcinoma were collected. BAL fluid was taken from part of the lung with malignancy, and from corresponding healthy side of the lung. VEGF and angiogenin concentrations were analysed by an enzyme-linked immunosorbent assay. Dilution of bronchial secretions in the BAL fluid was calculated from urea concentration ratio between serum and BAL fluid. RESULTS.: We found no statistical correlation between angiogenin concentrations in serum and in bronchial secretions from both parts of the lung. VEGF concentrations were greater in bronchial secretions in the affected side of the lung than on healthy side. Both concentrations were greater than serum VEGF concentration. VEGF concentration in serum was in positive correlation with tumour size (p = 0,003) and with metastatic stage of disease (p = 0,041). There was correlation between VEGF and angiogenin concentrations in bronchial secretions from healthy side of the lung and between VEGF and angiogenin concentrations in bronchial secretions from part of the lung with malignancy. CONCLUSION.: Angiogenin and VEGF concentrations in systemic, background and local samples of patients with lung cancer are affected by different mechanisms. Pro-angiogenic activity of lung cancer has an important influence on the levels of angiogenin and VEGF.

  13. Gamma-secretase inhibitor treatment promotes VEGF-A-driven blood vessel growth and vascular leakage but disrupts neovascular perfusion.

    Directory of Open Access Journals (Sweden)

    Mattias Kalén

    Full Text Available The Notch signaling pathway is essential for normal development due to its role in control of cell differentiation, proliferation and survival. It is also critically involved in tumorigenesis and cancer progression. A key enzyme in the activation of Notch signaling is the gamma-secretase protein complex and therefore, gamma-secretase inhibitors (GSIs--originally developed for Alzheimer's disease--are now being evaluated in clinical trials for human malignancies. It is also clear that Notch plays an important role in angiogenesis driven by Vascular Endothelial Growth Factor A (VEGF-A--a process instrumental for tumor growth and metastasis. The effect of GSIs on tumor vasculature has not been conclusively determined. Here we report that Compound X (CX, a GSI previously reported to potently inhibit Notch signaling in vitro and in vivo, promotes angiogenic sprouting in vitro and during developmental angiogenesis in mice. Furthermore, CX treatment suppresses tumor growth in a mouse model of renal carcinoma, leads to the formation of abnormal vessels and an increased tumor vascular density. Using a rabbit model of VEGF-A-driven angiogenesis in skeletal muscle, we demonstrate that CX treatment promotes abnormal blood vessel growth characterized by vessel occlusion, disrupted blood flow, and increased vascular leakage. Based on these findings, we propose a model for how GSIs and other Notch inhibitors disrupt tumor blood vessel perfusion, which might be useful for understanding this new class of anti-cancer agents.

  14. Gap junction protein connexin43 exacerbates lung vascular permeability.

    Directory of Open Access Journals (Sweden)

    James J O'Donnell

    Full Text Available Increased vascular permeability causes pulmonary edema that impairs arterial oxygenation and thus contributes to morbidity and mortality associated with Acute Respiratory Distress Syndrome and sepsis. Although components of intercellular adhesive and tight junctions are critical for maintaining the endothelial barrier, there has been limited study of the roles of gap junctions and their component proteins (connexins. Since connexins can modulate inflammatory signaling in other systems, we hypothesized that connexins may also regulate pulmonary endothelial permeability. The relationships between connexins and the permeability response to inflammatory stimuli were studied in cultured human pulmonary endothelial cells. Prolonged treatment with thrombin, lipopolysaccharide, or pathological cyclic stretch increased levels of mRNA and protein for the major connexin, connexin43 (Cx43. Thrombin and lipopolysaccharide both increased intercellular communication assayed by transfer of microinjected Lucifer yellow. Although thrombin decreased transendothelial resistance in these cells, the response was attenuated by pretreatment with the connexin inhibitor carbenoxolone. Additionally, the decreases of transendothelial resistance produced by either thrombin or lipopolysaccharide were attenuated by reducing Cx43 expression by siRNA knockdown. Both carbenoxolone and Cx43 knockdown also abrogated thrombin-induced phosphorylation of myosin light chain. Taken together, these data suggest that increased lung vascular permeability induced by inflammatory conditions may be amplified via increased expression of Cx43 and intercellular communication among pulmonary endothelial cells.

  15. Vascular and epithelial damage in the lung of the mouse after X rays or neutrons

    International Nuclear Information System (INIS)

    Law, M.P.; Ahier, R.G.

    1989-01-01

    The response of the lung was studied in CFLP mice after exposure of the whole thorax to X rays (250 kVp) or cyclotron neutrons (16 MeV deuterons on Be, mean energy 7.5 MeV). To measure blood volume and leakage of plasma proteins, 51Cr-labeled red blood cells and 125I-albumin were injected intravenously and 24 h later lungs were lavaged via the trachea. Radioactivities in lung tissue and lavage fluid were determined to estimate the accumulation of albumin in the interstitial and alveolar spaces indicating damage to blood vessels and alveolar epithelium respectively. Function of type II pneumonocytes was assessed by the amounts of surfactant (assayed as lipid phosphorous) released into the lavage fluid. During the first 6 weeks, lavage protein and surfactant were increased, the neutron relative biological effectiveness (RBE) being unity. During pneumonitis at 12-24 weeks, surfactant levels were normal, blood volume was decreased, and both interstitial and alveolar albumin were increased. Albumin levels then decreased. At late times after exposure (42-64 weeks) alveolar albumin returned to normal but interstitial albumin was still slightly elevated. Values of RBE for changes in blood volume and interstitial and alveolar albumin at 15 weeks and for changes in blood volume and interstitial albumin at 46 weeks were 1.4, comparable with that for animal survival at 180 days. The results indicate that surfactant production is not critical for animal survival. They suggest that changes in blood vessels and alveolar epithelium occur during acute pneumonitis; epithelial repair follows but some vascular damage may persist. The time course of the changes in albumin levels did not correlate with increases in collagen biosynthesis which have been observed as early as 1 month after exposure and persist for up to 1 year

  16. Lung irradiation induces pulmonary vascular remodelling resembling pulmonary arterial hypertension

    NARCIS (Netherlands)

    Ghobadi, G.; Bartelds, B.; van der Veen, S. J.; Dickinson, M. G.; Brandenburg, S.; Berger, R. M. F.; Langendijk, J. A.; Coppes, R. P.; van Luijk, P.

    Background Pulmonary arterial hypertension (PAH) is a commonly fatal pulmonary vascular disease that is often diagnosed late and is characterised by a progressive rise in pulmonary vascular resistance resulting from typical vascular remodelling. Recent data suggest that vascular damage plays an

  17. Post-treatment vascular leakage and inflammatory responses around brain cysts in porcine neurocysticercosis.

    Directory of Open Access Journals (Sweden)

    Siddhartha Mahanty

    2015-03-01

    Full Text Available Cysticidal treatment of neurocysticercosis, an infection of humans and pig brains with Taenia solium, results in an early inflammatory response directed to cysts causing seizures and focal neurological manifestations. Treatment-induced pericystic inflammation and its association with blood brain barrier (BBB dysfunction, as determined by Evans blue (EB extravasation, was studied in infected untreated and anthelmintic-treated pigs. We compared the magnitude and extent of the pericystic inflammation, presence of EB-stained capsules, the level of damage to the parasite, expression of genes for proinflammatory and regulatory cytokines, chemokines, and tissue remodeling by quantitative PCR assays between treated and untreated infected pigs and between EB-stained (blue and non stained (clear cysts. Inflammatory scores were higher in pericystic tissues from EB-stained cysts compared to clear cysts from untreated pigs and also from anthelmintic-treated pigs 48 hr and 120 hr after treatment. The degree of inflammation correlated with the severity of cyst wall damage and both increased significantly at 120 hours. Expression levels of the proinflammatory genes for IL-6, IFN-γ, TNF-α were higher in EB-stained cysts compared to clear cysts and unaffected brain tissues, and were generally highest at 120 hr. Additionally, expression of some markers of immunoregulatory activity (IL-10, IL-2Rα were decreased in EB-stained capsules. An increase in other markers for regulatory T cells (CTLA4, FoxP3 was found, as well as significant increases in expression of two metalloproteases, MMP1 and MMP2 at 48 hr and 120 hr post-treatment. We conclude that the increase in severity of the inflammation caused by treatment is accompanied by both a proinflammatory and a complex regulatory response, largely limited to pericystic tissues with compromised vascular integrity. Because treatment induced inflammation occurs in porcine NCC similar to that in human cases, this model

  18. From here to there, progenitor cells and stem cells are everywhere in lung vascular remodeling

    Directory of Open Access Journals (Sweden)

    Rebecca L. Heise

    2016-08-01

    Full Text Available The field of stem cell biology, cell therapy and regenerative medicine has expanded almost exponentially in the last decade. Clinical trials are evaluating the potential therapeutic use of stem cells in many adult and pediatric lung diseases with vascular component, such as bronchopulmonary dysplasia (BPD, chronic obstructive pulmonary disease (COPD, idiopathic pulmonary fibrosis (IPF or pulmonary arterial hypertension (PAH. Extensive research activity is exploring lung resident and circulating progenitor cells and their contribution to vascular complications of chronic lung diseases, and researchers hope to use resident or circulating stem/progenitor cells to treat chronic lung diseases and their vascular complications. It is becoming more and more clear that progress in mechanobiology will help to understand the various influences of physical forces and extracellular matrix composition on the phenotype and features of the progenitor cells and stem cells. The current review provides an overview of current concepts in the field.

  19. Expression of lung vascular and airway ICAM-1 after exposure to bacterial lipopolysaccharide

    DEFF Research Database (Denmark)

    Beck-Schimmer, B; Schimmer, R C; Warner, R L

    1997-01-01

    model. This increase was reduced by 81% after treatment of animals with anti-tumor necrosis factor-alpha (TNF-alpha) antibody and by 37% after treatment with anti-interleukin-1 (IL-1) antibody. The same interventions reduced whole-lung ICAM-1 protein by 85% and 25%, respectively. The studies were...... extended to assess the locale in lung of ICAM-I upregulation. Lung vascular ICAM-1 content, which was assessed by vascular fixation of [125I]anti-ICAM-1, rose 4-fold after airway instillation of LPS. This rise was also TNF-alpha-dependent. Under the same experimental conditions, fixation of [125I...... lavage fluids (BALFs) of animals after intratracheal instillation of LPS. Retrieved alveolar macrophages showed a small, significant, and transient increase in surface expression of ICAM-1. These data indicate, at the very least, a dual compartmentalized (vascular and airway) upregulation of ICAM-1 after...

  20. Effects of irradiation on the vascularity of lung

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, K; Takegawa, Y; Nagase, M; Akiyama, H [Tokushima Univ. (Japan). School of Medicine

    1975-06-01

    Effects of irradiation on the intravascular volume of the lung were studied with respect to changes in intravascular volume over a period of time after irradiation, the effect of fractionation of the dose and the influence of the irradiation dose rate. After a single irradiation with 1000 rad or 3000 rad, applied locally to the lung, the intravascular volume decreased significantly in 1 to 3 months after irradiation. The changes in the intravascular volumes of lungs could be lessened by fractionation of the dose or by low dose rate irradiation.

  1. Extravascular lung water and the pulmonary vascular permeability index may improve the definition of ARDS

    OpenAIRE

    Perel, Azriel

    2013-01-01

    The recent Berlin definition has made some improvements in the older definition of acute respiratory distress syndrome (ARDS), although the concepts and components of the definition remained largely unchanged. In an effort to improve both predictive and face validity, the Berlin panel has examined a number of additional measures that may reflect increased pulmonary vascular permeability, including extravascular lung water. The panel concluded that although extravascular lung water has improve...

  2. AIRFIX: the first digital postoperative chest tube airflowmetry--a novel method to quantify air leakage after lung resection.

    Science.gov (United States)

    Anegg, Udo; Lindenmann, Jorg; Matzi, Veronika; Mujkic, Dzenana; Maier, Alfred; Fritz, Lukas; Smolle-Jüttner, Freyja Maria

    2006-06-01

    Prolonged air leak after pulmonary resection is a common complication and a major limiting factor for early discharge from hospital. Currently there is little consensus on its management. The aim of this study was to develop and evaluate a measuring device which allows a simple digital bed-side quantification of air-leaks compatible to standard thoracic drainage systems. The measuring device (AIRFIX) is based upon a 'mass airflow' sensor with a specially designed software package that is connected to a thoracic suction drainage system. Its efficacy in detecting pulmonary air-leaks was evaluated in a series of 204 patients; all postoperative measurements were done under standardized conditions; the patients were asked to cough, to take a deep breath, to breathe out against the resistance of a flutter valve, to keep breath and to breathe normally. As standard parameters, the leakage per breath or cough (ml/b) as well as the leakage per minute (ml/min) were displayed and recorded on the computer. Air-leaks within a range of 0.25-45 ml/b and 5-900 ml/min were found. Removal of the chest tubes was done when leakage volume on Heimlich valve was less than 1.0 ml/b or 20 ml/min. After drain removal based upon the data from chest tube airflowmetry none of the patients needed re-drainage due to pneumothorax. The AIRFIX device for bed-side quantification of air-leaks has proved to be very simple and helpful in diagnosis and management of air-leaks after lung surgery, permitting drain removal without tentative clamping.

  3. Clostridium sordellii lethal toxin kills mice by inducing a major increase in lung vascular permeability.

    Science.gov (United States)

    Geny, Blandine; Khun, Huot; Fitting, Catherine; Zarantonelli, Leticia; Mazuet, Christelle; Cayet, Nadège; Szatanik, Marek; Prevost, Marie-Christine; Cavaillon, Jean-Marc; Huerre, Michel; Popoff, Michel R

    2007-03-01

    When intraperitoneally injected into Swiss mice, Clostridium sordellii lethal toxin reproduces the fatal toxic shock syndrome observed in humans and animals after natural infection. This animal model was used to study the mechanism of lethal toxin-induced death. Histopathological and biochemical analyses identified lung and heart as preferential organs targeted by lethal toxin. Massive extravasation of blood fluid in the thoracic cage, resulting from an increase in lung vascular permeability, generated profound modifications such as animal dehydration, increase in hematocrit, hypoxia, and finally, cardiorespiratory failure. Vascular permeability increase induced by lethal toxin resulted from modifications of lung endothelial cells as evidenced by electron microscopy. Immunohistochemical analysis demonstrated that VE-cadherin, a protein participating in intercellular adherens junctions, was redistributed from membrane to cytosol in lung endothelial cells. No major sign of lethal toxin-induced inflammation was observed that could participate in the toxic shock syndrome. The main effect of the lethal toxin is the glucosylation-dependent inactivation of small GTPases, in particular Rac, which is involved in actin polymerization occurring in vivo in lungs leading to E-cadherin junction destabilization. We conclude that the cells most susceptible to lethal toxin are lung vascular endothelial cells, the adherens junctions of which were altered after intoxication.

  4. Targeting of the pulmonary capillary vascular niche promotes lung alveolar repair and ameliorates fibrosis.

    Science.gov (United States)

    Cao, Zhongwei; Lis, Raphael; Ginsberg, Michael; Chavez, Deebly; Shido, Koji; Rabbany, Sina Y; Fong, Guo-Hua; Sakmar, Thomas P; Rafii, Shahin; Ding, Bi-Sen

    2016-02-01

    Although the lung can undergo self-repair after injury, fibrosis in chronically injured or diseased lungs can occur at the expense of regeneration. Here we study how a hematopoietic-vascular niche regulates alveolar repair and lung fibrosis. Using intratracheal injection of bleomycin or hydrochloric acid in mice, we show that repetitive lung injury activates pulmonary capillary endothelial cells (PCECs) and perivascular macrophages, impeding alveolar repair and promoting fibrosis. Whereas the chemokine receptor CXCR7, expressed on PCECs, acts to prevent epithelial damage and ameliorate fibrosis after a single round of treatment with bleomycin or hydrochloric acid, repeated injury leads to suppression of CXCR7 expression and recruitment of vascular endothelial growth factor receptor 1 (VEGFR1)-expressing perivascular macrophages. This recruitment stimulates Wnt/β-catenin-dependent persistent upregulation of the Notch ligand Jagged1 (encoded by Jag1) in PCECs, which in turn stimulates exuberant Notch signaling in perivascular fibroblasts and enhances fibrosis. Administration of a CXCR7 agonist or PCEC-targeted Jag1 shRNA after lung injury promotes alveolar repair and reduces fibrosis. Thus, targeting of a maladapted hematopoietic-vascular niche, in which macrophages, PCECs and perivascular fibroblasts interact, may help to develop therapy to spur lung regeneration and alleviate fibrosis.

  5. Targeting of the pulmonary capillary vascular niche promotes lung alveolar repair and ameliorates fibrosis

    Science.gov (United States)

    Cao, Zhongwei; Lis, Raphael; Ginsberg, Michael; Chavez, Deebly; Shido, Koji; Rabbany, Sina Y.; Fong, Guo-Hua; Sakmar, Thomas P.; Rafii, Shahin; Ding, Bi-Sen

    2016-01-01

    Although the lung can undergo self-repair after injury, fibrosis in chronically injured or diseased lungs can occur at the expense of regeneration. Here we study how a hematopoietic-vascular niche regulates alveolar repair and lung fibrosis. Using intratracheal injection of bleomycin or hydrochloric acid in mice, we show that repetitive lung injury activates pulmonary capillary endothelial cells (PCECs) and perivascular macrophages, impeding alveolar repair and promoting fibrosis. Whereas the chemokine receptor CXCR7, expressed on PCECs, acts to prevent epithelial damage and ameliorate fibrosis after a single round of treatment with bleomycin or hydrochloric acid, repeated injury leads to suppression of CXCR7 expression and recruitment of vascular endothelial growth factor receptor 1 (VEGFR1)-expressing perivascular macrophages. This recruitment stimulates Wnt/β-catenin–dependent persistent upregulation of the Notch ligand Jagged1 (encoded by Jag1) in PCECs, which in turn stimulates exuberant Notch signaling in perivascular fibroblasts and enhances fibrosis. Administration of a CXCR7 agonist or PCEC-targeted Jag1 shRNA after lung injury promotes alveolar repair and reduces fibrosis. Thus, targeting of a maladaptbed hematopoietic-vascular niche, in which macrophages, PCECs and perivascular fibroblasts interact, may help to develop therapy to spur lung regeneration and alleviate fibrosis. PMID:26779814

  6. Lung heparan sulfates modulate Kfc during increased vascular pressure: evidence for glycocalyx-mediated mechanotransduction

    Science.gov (United States)

    Cluff, Mark; Kingston, Joseph; Hill, Denzil; Chen, Haiyan; Hoehne, Soeren; Malleske, Daniel T.; Kaur, Rajwinederjit

    2012-01-01

    Lung endothelial cells respond to changes in vascular pressure through mechanotransduction pathways that alter barrier function via non-Starling mechanism(s). Components of the endothelial glycocalyx have been shown to participate in mechanotransduction in vitro and in systemic vessels, but the glycocalyx's role in mechanosensing and pulmonary barrier function has not been characterized. Mechanotransduction pathways may represent novel targets for therapeutic intervention during states of elevated pulmonary pressure such as acute heart failure, fluid overload, and mechanical ventilation. Our objective was to assess the effects of increasing vascular pressure on whole lung filtration coefficient (Kfc) and characterize the role of endothelial heparan sulfates in mediating mechanotransduction and associated increases in Kfc. Isolated perfused rat lung preparation was used to measure Kfc in response to changes in vascular pressure in combination with superimposed changes in airway pressure. The roles of heparan sulfates, nitric oxide, and reactive oxygen species were investigated. Increases in capillary pressure altered Kfc in a nonlinear relationship, suggesting non-Starling mechanism(s). nitro-l-arginine methyl ester and heparanase III attenuated the effects of increased capillary pressure on Kfc, demonstrating active mechanotransduction leading to barrier dysfunction. The nitric oxide (NO) donor S-nitrosoglutathione exacerbated pressure-mediated increase in Kfc. Ventilation strategies altered lung NO concentration and the Kfc response to increases in vascular pressure. This is the first study to demonstrate a role for the glycocalyx in whole lung mechanotransduction and has important implications in understanding the regulation of vascular permeability in the context of vascular pressure, fluid status, and ventilation strategies. PMID:22160307

  7. HRCT of the lung in collagen vascular diseases

    International Nuclear Information System (INIS)

    Diederich, S.; Roos, N.; Schmitz-Linneweber, B.; Gaubitz, M.; Peters, P.E.

    1996-01-01

    Collagen vascular diseases, representing systemic soft tissue disorders, may cause a broad spectrum of pathologic changes of the respiratory tract. The type and extent of manifestations can vary considerably among individuals and entities. This survey describes the chest radiographic and, in particular, high-resolution computed tomographic and, in particular, high-resolution computed tomographic (HRCT) findings of individual lesions of the respiratory tract. It includes fibrosing alveolitis (alveolitis, interstitial pneumonia, pulmonary fibrosis) and bronchial (bronchitis/bronchiolitis, bronchiectasis), pleural and vascular manifestations, as well as lymphadenopathy and abnormalities related to therapy. We present typical patterns of changes in progressive systemic sclerosis (PSS, scleroderma), systemic lupus erythematosus (SLE), mixed connective tissue disease (MCTD, Sharp syndrome), Sjoegren syndrome, overlap syndrome and rheumatoid arthritis (RA). Furthermore, we describe findings which are specific for individual entities such as esophageal involvement in PSS, acute pneumonitis and pulmonary hemorrhage in SLE, lymphoproliferative disease in Sjoegren syndrome and necrobiotic nodules in RA. (orig.) [de

  8. Α-Melanocyte-Stimulating Hormone Protects Early Diabetic Retina from Blood-Retinal Barrier Breakdown and Vascular Leakage via MC4R.

    Science.gov (United States)

    Cai, Siwei; Yang, Qianhui; Hou, Mengzhu; Han, Qian; Zhang, Hanyu; Wang, Jiantao; Qi, Chen; Bo, Qiyu; Ru, Yusha; Yang, Wei; Gu, Zhongxiu; Wei, Ruihua; Cao, Yunshan; Li, Xiaorong; Zhang, Yan

    2018-01-01

    Blood-retinal barrier (BRB) breakdown and vascular leakage is the leading cause of blindness of diabetic retinopathy (DR). Hyperglycemia-induced oxidative stress and inflammation are primary pathogenic factors of this severe DR complication. An effective interventional modality against the pathogenic factors during early DR is needed to curb BRB breakdown and vascular leakage. This study sought to examine the protective effects of α-Melanocyte-stimulating hormone (α-MSH) on early diabetic retina against vascular hyperpermeability, electrophysiological dysfunction, and morphological deterioration in a rat model of diabetes and probe the mechanisms underlying the α-MSH's anti-hyperpermeability in both rodent retinas and simian retinal vascular endothelial cells (RF6A). Sprague Dawley rats were injected through tail vein with streptozotocin to induce diabetes. The rats were intravitreally injected with α-MSH or saline at Week 1 and 3 after hyperglycemia. In another 2 weeks, Evans blue assay, transmission electron microscopy, electroretinogram (ERG), and hematoxylin and eosin (H&E) staining were performed to examine the protective effects of α-MSH in diabetic retinas. The expression of pro-inflammatory factors and tight junction at mRNA and protein levels in retinas was analyzed. Finally, the α-MSH's anti-hyperpermeability was confirmed in a high glucose (HG)-treated RF6A cell monolayer transwell culture by transendothelial electrical resistance (TEER) measurement and a fluorescein isothiocyanate-Dextran assay. Universal or specific melanocortin receptor (MCR) blockers were also employed to elucidate the MCR subtype mediating α-MSH's protection. Evans blue assay showed that BRB breakdown and vascular leakage was detected, and rescued by α-MSH both qualitatively and quantitatively in early diabetic retinas; electron microscopy revealed substantially improved retinal and choroidal vessel ultrastructures in α-MSH-treated diabetic retinas; scotopic ERG suggested

  9. Targeting the vascular and perivascular niches as a regenerative therapy for lung and liver fibrosis.

    Science.gov (United States)

    Cao, Zhongwei; Ye, Tinghong; Sun, Yue; Ji, Gaili; Shido, Koji; Chen, Yutian; Luo, Lin; Na, Feifei; Li, Xiaoyan; Huang, Zhen; Ko, Jane L; Mittal, Vivek; Qiao, Lina; Chen, Chong; Martinez, Fernando J; Rafii, Shahin; Ding, Bi-Sen

    2017-08-30

    The regenerative capacity of lung and liver is sometimes impaired by chronic or overwhelming injury. Orthotopic transplantation of parenchymal stem cells to damaged organs might reinstate their self-repair ability. However, parenchymal cell engraftment is frequently hampered by the microenvironment in diseased recipient organs. We show that targeting both the vascular niche and perivascular fibroblasts establishes "hospitable soil" to foster the incorporation of "seed," in this case, the engraftment of parenchymal cells in injured organs. Specifically, ectopic induction of endothelial cell (EC)-expressed paracrine/angiocrine hepatocyte growth factor (HGF) and inhibition of perivascular NOX4 [NADPH (reduced form of nicotinamide adenine dinucleotide phosphate) oxidase 4] synergistically enabled reconstitution of mouse and human parenchymal cells in damaged organs. Reciprocally, genetic knockout of Hgf in mouse ECs ( Hgf iΔEC/iΔEC ) aberrantly up-regulated perivascular NOX4 during liver and lung regeneration. Dysregulated HGF and NOX4 pathways subverted the function of vascular and perivascular cells from an epithelially inductive niche to a microenvironment that inhibited parenchymal reconstitution. Perivascular NOX4 induction in Hgf iΔEC/iΔEC mice recapitulated the phenotype of human and mouse liver and lung fibrosis. Consequently, EC-directed HGF and NOX4 inhibitor GKT137831 stimulated regenerative integration of mouse and human parenchymal cells in chronically injured lung and liver. Our data suggest that targeting dysfunctional perivascular and vascular cells in diseased organs can bypass fibrosis and enable reparative cell engraftment to reinstate lung and liver regeneration. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  10. Influence of vascular network design on gas transfer in lung assist device technology.

    Science.gov (United States)

    Bassett, Erik K; Hoganson, David M; Lo, Justin H; Penson, Elliot J N; Vacanti, Joseph P

    2011-01-01

    Blood oxygenators are vital for the critically ill, but their use is limited to the hospital setting. A portable blood oxygenator or a lung assist device for ambulatory or long-term use would greatly benefit patients with chronic lung disease. In this work, a biomimetic blood oxygenator system was developed which consisted of a microfluidic vascular network covered by a gas permeable silicone membrane. This system was used to determine the influence of key microfluidic parameters-channel size, oxygen exposure length, and blood shear rate-on blood oxygenation and carbon dioxide removal. Total gas transfer increased linearly with flow rate, independent of channel size and oxygen exposure length. On average, CO(2) transfer was 4.3 times higher than oxygen transfer. Blood oxygen saturation was also found to depend on the flow rate per channel but in an inverse manner; oxygenation decreased and approached an asymptote as the flow rate per channel increased. These relationships can be used to optimize future biomimetic vascular networks for specific lung applications: gas transfer for carbon dioxide removal in patients with chronic obstructive pulmonary disease or oxygenation for premature infants requiring complete lung replacement therapy.

  11. Clinical implications for Vascular Endothelial Growth Factor in the lung: friend or foe?

    Directory of Open Access Journals (Sweden)

    Gourgoulianis Konstantinos I

    2006-10-01

    Full Text Available Abstract Vascular endothelial growth factor (VEGF is a potent mediator of angiogenesis which has multiple effects in lung development and physiology. VEGF is expressed in several parts of the lung and the pleura while it has been shown that changes in its expression play a significant role in the pathophysiology of some of the most common respiratory disorders, such as acute lung injury, asthma, chronic obstructive pulmonary disease, obstructive sleep apnea, idiopathic pulmonary fibrosis, pulmonary hypertension, pleural disease, and lung cancer. However, the exact role of VEGF in the lung is not clear yet, as there is contradictory evidence that suggests either a protective or a harmful role. VEGF seems to interfere in a different manner, depending on its amount, the location, and the underlying pathologic process in lung tissue. The lack of VEGF in some disease entities may provide implications for its substitution, whereas its overexpression in other lung disorders has led to interventions for the attenuation of its action. Many efforts have been made in order to regulate the expression of VEGF and anti-VEGF antibodies are already in use for the management of lung cancer. Further research is still needed for the complete understanding of the exact role of VEGF in health and disease, in order to take advantage of its benefits and avoid its adverse effects. The scope of the present review is to summarize from a clinical point of view the changes in VEGF expression in several disorders of the respiratory system and focus on its diagnostic and therapeutic implications.

  12. Dual modal ultra-bright nanodots with aggregation-induced emission and gadolinium-chelation for vascular integrity and leakage detection.

    Science.gov (United States)

    Feng, Guangxue; Li, Jackson Liang Yao; Claser, Carla; Balachander, Akhila; Tan, Yingrou; Goh, Chi Ching; Kwok, Immanuel Weng Han; Rénia, Laurent; Tang, Ben Zhong; Ng, Lai Guan; Liu, Bin

    2018-01-01

    The study of blood brain barrier (BBB) functions is important for neurological disorder research. However, the lack of suitable tools and methods has hampered the progress of this field. Herein, we present a hybrid nanodot strategy, termed AIE-Gd dots, comprising of a fluorogen with aggregation-induced emission (AIE) characteristics as the core to provide bright and stable fluorescence for optical imaging, and gadolinium (Gd) for accurate quantification of vascular leakage via inductively-coupled plasma mass spectrometry (ICP-MS). In this report, we demonstrate that AIE-Gd dots enable direct visualization of brain vascular networks under resting condition, and that they form localized punctate aggregates and accumulate in the brain tissue during experimental cerebral malaria, indicative of hemorrhage and BBB malfunction. With its superior detection sensitivity and multimodality, we hereby propose that AIE-Gd dots can serve as a better alternative to Evans blue for visualization and quantification of changes in brain barrier functions. Copyright © 2017. Published by Elsevier Ltd.

  13. Placenta growth factor and vascular endothelial growth factor B expression in the hypoxic lung

    LENUS (Irish Health Repository)

    Sands, Michelle

    2011-01-25

    Abstract Background Chronic alveolar hypoxia, due to residence at high altitude or chronic obstructive lung diseases, leads to pulmonary hypertension, which may be further complicated by right heart failure, increasing morbidity and mortality. In the non-diseased lung, angiogenesis occurs in chronic hypoxia and may act in a protective, adaptive manner. To date, little is known about the behaviour of individual vascular endothelial growth factor (VEGF) family ligands in hypoxia-induced pulmonary angiogenesis. The aim of this study was to examine the expression of placenta growth factor (PlGF) and VEGFB during the development of hypoxic pulmonary angiogenesis and their functional effects on the pulmonary endothelium. Methods Male Sprague Dawley rats were exposed to conditions of normoxia (21% O2) or hypoxia (10% O2) for 1-21 days. Stereological analysis of vascular structure, real-time PCR analysis of vascular endothelial growth factor A (VEGFA), VEGFB, placenta growth factor (PlGF), VEGF receptor 1 (VEGFR1) and VEGFR2, immunohistochemistry and western blots were completed. The effects of VEGF ligands on human pulmonary microvascular endothelial cells were determined using a wound-healing assay. Results Typical vascular remodelling and angiogenesis were observed in the hypoxic lung. PlGF and VEGFB mRNA expression were significantly increased in the hypoxic lung. Immunohistochemical analysis showed reduced expression of VEGFB protein in hypoxia although PlGF protein was unchanged. The expression of VEGFA mRNA and protein was unchanged. In vitro PlGF at high concentration mimicked the wound-healing actions of VEGFA on pulmonary microvascular endothelial monolayers. Low concentrations of PlGF potentiated the wound-healing actions of VEGFA while higher concentrations of PlGF were without this effect. VEGFB inhibited the wound-healing actions of VEGFA while VEGFB and PlGF together were mutually antagonistic. Conclusions VEGFB and PlGF can either inhibit or potentiate the

  14. Placenta growth factor and vascular endothelial growth factor B expression in the hypoxic lung

    Directory of Open Access Journals (Sweden)

    McLoughlin Paul

    2011-01-01

    Full Text Available Abstract Background Chronic alveolar hypoxia, due to residence at high altitude or chronic obstructive lung diseases, leads to pulmonary hypertension, which may be further complicated by right heart failure, increasing morbidity and mortality. In the non-diseased lung, angiogenesis occurs in chronic hypoxia and may act in a protective, adaptive manner. To date, little is known about the behaviour of individual vascular endothelial growth factor (VEGF family ligands in hypoxia-induced pulmonary angiogenesis. The aim of this study was to examine the expression of placenta growth factor (PlGF and VEGFB during the development of hypoxic pulmonary angiogenesis and their functional effects on the pulmonary endothelium. Methods Male Sprague Dawley rats were exposed to conditions of normoxia (21% O2 or hypoxia (10% O2 for 1-21 days. Stereological analysis of vascular structure, real-time PCR analysis of vascular endothelial growth factor A (VEGFA, VEGFB, placenta growth factor (PlGF, VEGF receptor 1 (VEGFR1 and VEGFR2, immunohistochemistry and western blots were completed. The effects of VEGF ligands on human pulmonary microvascular endothelial cells were determined using a wound-healing assay. Results Typical vascular remodelling and angiogenesis were observed in the hypoxic lung. PlGF and VEGFB mRNA expression were significantly increased in the hypoxic lung. Immunohistochemical analysis showed reduced expression of VEGFB protein in hypoxia although PlGF protein was unchanged. The expression of VEGFA mRNA and protein was unchanged. In vitro PlGF at high concentration mimicked the wound-healing actions of VEGFA on pulmonary microvascular endothelial monolayers. Low concentrations of PlGF potentiated the wound-healing actions of VEGFA while higher concentrations of PlGF were without this effect. VEGFB inhibited the wound-healing actions of VEGFA while VEGFB and PlGF together were mutually antagonistic. Conclusions VEGFB and PlGF can either inhibit or

  15. Extravascular lung water and the pulmonary vascular permeability index may improve the definition of ARDS.

    Science.gov (United States)

    Perel, Azriel

    2013-01-24

    The recent Berlin definition has made some improvements in the older definition of acute respiratory distress syndrome (ARDS), although the concepts and components of the definition remained largely unchanged. In an effort to improve both predictive and face validity, the Berlin panel has examined a number of additional measures that may reflect increased pulmonary vascular permeability, including extravascular lung water. The panel concluded that although extravascular lung water has improved face validity and higher values are associated with mortality, it is infeasible to mandate on the basis of availability and the fact that it does not distinguish between hydrostatic and inflammatory pulmonary edema. However, the results of a multi-institutional study that appeared in the previous issue of Critical Care show that this latter reservation may not necessarily be true. By using extravascular lung water and the pulmonary vascular permeability index, both of which are derived from transpulmonary thermodilution, the authors could successfully differentiate between patients with ARDS and other patients in respiratory failure due to either cardiogenic edema or pleural effusion with atelectasis. This commentary discusses the merits and limitations of this study in view of the potential improvement that transpulmonary thermodilution may bring to the definition of ARDS.

  16. Use of spiral CT angiography to judge central pulmonary vascular involvement from lung cancer

    International Nuclear Information System (INIS)

    Tan Qunyou; Zhao Shaohong; Wang Fangze; Cai Zulong

    2000-01-01

    Objective: To evaluate the accuracy of spiral CT angiography (SCTA) in judging central pulmonary vascular involvement from lung cancer located in the hilum and correlate the resultant images with pathologic and surgical findings. Methods: SCTA was done in 33 patients who were preoperatively diagnosed as having lung carcinoma located in the hilum. Contrast medium was injected at a rate of 3 ml/sec with a power injector. The delay time was from 20 to 25 seconds. The pitch was 1 with 3 mm-collimation. Images of central pulmonary arteries and veins were reconstructed with shaded surface display (SSD), maximum intensity projection (MIP), curved planar reformation (CPR), and multi-planar reformation (MPR). Then the relation between tumor and vessels was assessed prospectively on both 3 mm interval axial CT and SCTA images with comparison to subsequent pathologic or surgical findings. Results: (1) In showing the integrity of central pulmonary arteries and veins, images reconstructed by different ways of SCTA had different strong and weak points. (2) The grading standard in this study, with which the relation between vessels and tumor was judged, reflected the basic and common characters of central pulmonary vascular involvement by tumor located in the hilum. compared with axial CT images, SCTA was more accurate in judging the relation between central pulmonary vessels and tumor, and the correlation of SCTA imaging features with pathological patterns and surgical findings was better than that of axial CT images, P < 0.05 and P < 0.0001, respectively. Conclusion: It was feasible to show the relation between central pulmonary vessel and lung cancer located in the hilum with SCTA. And the accuracy of judging the vascular involvement with SCTA was higher than that with axial CT

  17. Pulmonary Vascular Congestion: A Mechanism for Distal Lung Unit Dysfunction in Obesity.

    Science.gov (United States)

    Oppenheimer, Beno W; Berger, Kenneth I; Ali, Saleem; Segal, Leopoldo N; Donnino, Robert; Katz, Stuart; Parikh, Manish; Goldring, Roberta M

    2016-01-01

    Obesity is characterized by increased systemic and pulmonary blood volumes (pulmonary vascular congestion). Concomitant abnormal alveolar membrane diffusion suggests subclinical interstitial edema. In this setting, functional abnormalities should encompass the entire distal lung including the airways. We hypothesize that in obesity: 1) pulmonary vascular congestion will affect the distal lung unit with concordant alveolar membrane and distal airway abnormalities; and 2) the degree of pulmonary congestion and membrane dysfunction will relate to the cardiac response. 54 non-smoking obese subjects underwent spirometry, impulse oscillometry (IOS), diffusion capacity (DLCO) with partition into membrane diffusion (DM) and capillary blood volume (VC), and cardiac MRI (n = 24). Alveolar-capillary membrane efficiency was assessed by calculation of DM/VC. Mean age was 45±12 years; mean BMI was 44.8±7 kg/m2. Vital capacity was 88±13% predicted with reduction in functional residual capacity (58±12% predicted). Despite normal DLCO (98±18% predicted), VC was elevated (135±31% predicted) while DM averaged 94±22% predicted. DM/VC varied from 0.4 to 1.4 with high values reflecting recruitment of alveolar membrane and low values indicating alveolar membrane dysfunction. The most abnormal IOS (R5 and X5) occurred in subjects with lowest DM/VC (r2 = 0.31, ppulmonary vascular congestion and failure to achieve the high output state of obesity. Pulmonary vascular congestion and consequent fluid transudation and/or alterations in the structure of the alveolar capillary membrane may be considered often unrecognized causes of airway dysfunction in obesity.

  18. FDG uptake in the fatty tissues of supraclavicular and the vascular structure of the lung hilum

    International Nuclear Information System (INIS)

    Dang Yaping; Liu Gang; Li Miao

    2004-01-01

    Objectives: To investigate FDG uptake on the sites of supraclavicular region (SR) and the lung hilum (LH) and find out the exact tissues of the uptake. Methods: Supraclavicular region (SR) and lung hilum (LH) are common sites for lymph node metastases. A commonly reported site of non-malignant FDG uptake on PET imaging in the SR is muscular uptake. PET/CT offers a unique technique to correlate PET findings with CT anatomy in the SR and EH. From September 2002 to March 2003, 147 consecutive clinical patients imaged by FDG PET/CT whole-body scan (GE Discovery LS, CT attenuation correction, OSEM reconstruction) were retrospectively reviewed. The presence of abnormal FDG uptake on PET images in the sites of SR and LH regions was evaluated and the corresponding CT findings on the same regions were also assessed. Results: Of 147 patients, 8 cases (2M, 6F and mean age 44 years) were found with increased symmetrical FDG uptake in the regions of the lower neck and shoulder as well as costo-vertebral articulations, the positive rates were 2.1% and 11.3 % for men and women respectively, and the average rate was 5.4%. However, no FDG uptake was seen in the greater muscular structures of the cervical or thoracic spine. FDG uptake was seen in the fatty tissue between the shoulder muscle and the dorsal thoracic wall, but not within the muscles itself. Five patients (3M, 2F, age 56-74 years,3.4%) showed abnormal LH FDG uptake, which were definitely localized in the vascular structure of the lung hilum by CT Conclusion: Co-registered PET/CT imaging shows that the FDG uptake been well known in the SR and LH regions are not fully located in greater muscular structures and lymph nodes, but in the costo-vertebral articulation complex of the thoracic spine and fatty tissue of the shoulders as well as in the vascular structure of both lung hilum. The FDG uptake in the fatty tissue of the shoulders was mostly seen in women, while the uptake in vascular structure of the lung hilum were

  19. Correlation between matrix metalloproteinase-9 and vascular endothelial growth factor expression in lung adenocarcinoma.

    Science.gov (United States)

    Wen, Y L; Li, L

    2015-12-29

    The aim of this study was to investigate the correlation between the expression of matrix metalloproteinase-9 (MMP-9) and vascular endothelial growth factor (VEGF) and clinicopathological features of lung adenocarcinoma. The expression of MMP-9 and VEGF was evaluated by immunohistochemistry of 30 samples from lung adenocarcinoma patients and 12 paratumoral (normal) tissue samples. In addition, the change in VEGF or MMP-9 expression after MMP-9 or VEGF blockade, respectively, was measured using western blot in lung adenocarcinoma A549 cells. High expression of MMP-9 was found in 63.3% of adenocarcinoma tissues versus 16.7% in normal tissues (P correlation was identified between MMP-9 and VEGF expression (correlation coefficient = 0.7094, P < 0.001), and their mutual overexpression was associated with clinical staging and lymph node status (P < 0.05). In addition, an decrease in VEGF protein expression was observed after MMP-9 blockade by an MMP-9-specific monoclonal antibody. Similarly, a decrease in MMP-9 protein expression was found after VEGF blockade by a VEGF-specific monoclonal antibody. In conclusion, VEGF and MMP-9 are overexpressed in lung adenocarcinoma tissues, and they have a synergistic effect on the invasion and metastasis of adenocarcinoma.

  20. Platelet Vascular Endothelial Growth Factor is a Potential Mediator of Transfusion-Related Acute Lung Injury.

    Science.gov (United States)

    Maloney, James P; Ambruso, Daniel R; Voelkel, Norbert F; Silliman, Christopher C

    The occurrence of non-hemolytic transfusion reactions is highest with platelet and plasma administration. Some of these reactions are characterized by endothelial leak, especially transfusion related acute lung injury (TRALI). Elevated concentrations of inflammatory mediators secreted by contaminating leukocytes during blood product storage may contribute to such reactions, but platelet-secreted mediators may also contribute. We hypothesized that platelet storage leads to accumulation of the endothelial permeability mediator vascular endothelial growth factor (VEGF), and that intravascular administration of exogenous VEGF leads to extensive binding to its lung receptors. Single donor, leukocyte-reduced apheresis platelet units were sampled over 5 days of storage. VEGF protein content of the centrifuged supernatant was determined by ELISA, and the potential contribution of VEGF from contaminating leukocytes was quantified. Isolated-perfused rat lungs were used to study the uptake of radiolabeled VEGF administered intravascularly, and the effect of unlabeled VEGF on lung leak. There was a time-dependent release of VEGF into the plasma fraction of the platelet concentrates (62 ± 9 pg/ml on day one, 149 ± 23 pg/ml on day 5; mean ± SEM, pproducts.

  1. HRCT of the lung in collagen vascular diseases; HRCT der Lunge bei Kollagenosen

    Energy Technology Data Exchange (ETDEWEB)

    Diederich, S. [Inst. fuer Klinische Radiologie, Westfaelische Wilhelms-Univ., Muenster (Germany); Roos, N. [Inst. fuer Klinische Radiologie, Westfaelische Wilhelms-Univ., Muenster (Germany); Schmitz-Linneweber, B. [Medizinische Klinik B, Westfaelische Wilhelms-Univ., Muenster (Germany); Gaubitz, M. [Medizinische Klinik B, Westfaelische Wilhelms-Univ., Muenster (Germany); Peters, P.E. [Inst. fuer Klinische Radiologie, Westfaelische Wilhelms-Univ., Muenster (Germany)

    1996-07-01

    Collagen vascular diseases, representing systemic soft tissue disorders, may cause a broad spectrum of pathologic changes of the respiratory tract. The type and extent of manifestations can vary considerably among individuals and entities. This survey describes the chest radiographic and, in particular, high-resolution computed tomographic and, in particular, high-resolution computed tomographic (HRCT) findings of individual lesions of the respiratory tract. It includes fibrosing alveolitis (alveolitis, interstitial pneumonia, pulmonary fibrosis) and bronchial (bronchitis/bronchiolitis, bronchiectasis), pleural and vascular manifestations, as well as lymphadenopathy and abnormalities related to therapy. We present typical patterns of changes in progressive systemic sclerosis (PSS, scleroderma), systemic lupus erythematosus (SLE), mixed connective tissue disease (MCTD, Sharp syndrome), Sjoegren syndrome, overlap syndrome and rheumatoid arthritis (RA). Furthermore, we describe findings which are specific for individual entities such as esophageal involvement in PSS, acute pneumonitis and pulmonary hemorrhage in SLE, lymphoproliferative disease in Sjoegren syndrome and necrobiotic nodules in RA. (orig.) [Deutsch] Die Kollagenosen koennen als systemische Bindegewebserkrankungen auch zu einem breiten Spektrum pathologischer Veraenderungen am Respirationstrakt fuehren, wobei sich Art und Ausmass der Manifestationen innerhalb einzelner Entitaeten und zwischen verschiedenen Krankheitsbildern erheblich unterscheiden koennen. In der vorliegenden Uebersicht werden die entsprechenden Befunde von Thoraxuebersichtsaufnahme und insbesondere hochaufloesender Computertomographie (HRCT) beschrieben. Beruecksichtigt werden dabei die fibrosierende Alveolitis (Alveolitis, interstitielle Pneumonie, Lungenfibrose), bronchiale (Bronchitis/Bronchiolitis, Bronchiektasen), pleurale und vaskulaere Manifestationen sowie Lymphadenopathie und therapie-induzierte Befunde. Typische Befundmuster

  2. Single Sustained Inflation followed by Ventilation Leads to Rapid Cardiorespiratory Recovery but Causes Cerebral Vascular Leakage in Asphyxiated Near-Term Lambs.

    Directory of Open Access Journals (Sweden)

    Kristina S Sobotka

    Full Text Available A sustained inflation (SI rapidly restores cardiac function in asphyxic, bradycardic newborns but its effects on cerebral haemodynamics and brain injury are unknown. We determined the effect of different SI strategies on carotid blood flow (CaBF and cerebral vascular integrity in asphyxiated near-term lambs.Lambs were instrumented and delivered at 139 ± 2 d gestation and asphyxia was induced by delaying ventilation onset. Lambs were randomised to receive 5 consecutive 3 s SI (multiple SI; n = 6, a single 30 s SI (single SI; n = 6 or conventional ventilation (no SI; n = 6. Ventilation continued for 30 min in all lambs while CaBF and respiratory function parameters were recorded. Brains were assessed for gross histopathology and vascular leakage.CaBF increased more rapidly and to a greater extent during a single SI (p = 0.01, which then decreased below both other groups by 10 min, due to a higher cerebral oxygen delivery (p = 0.01. Blood brain barrier disruption was increased in single SI lambs as indicated by increased numbers of blood vessel profiles with plasma protein extravasation (p = 0.001 in the cerebral cortex. There were no differences in CaBF or cerebral oxygen delivery between the multiple SI and no SI lambs.Ventilation with an initial single 30 s SI improves circulatory recovery, but is associated with greater disruption of blood brain barrier function, which may exacerbate brain injury suffered by asphyxiated newborns. This injury may occur as a direct result of the initial SI or to the higher tidal volumes delivered during subsequent ventilation.

  3. Pulmonary microvascular hyperpermeability and expression of vascular endothelial growth factor in smoke inhalation- and pneumonia-induced acute lung injury.

    Science.gov (United States)

    Lange, Matthias; Hamahata, Atsumori; Traber, Daniel L; Connelly, Rhykka; Nakano, Yoshimitsu; Traber, Lillian D; Schmalstieg, Frank C; Herndon, David N; Enkhbaatar, Perenlei

    2012-11-01

    Acute lung injury (ALI) and sepsis are major contributors to the morbidity and mortality of critically ill patients. The current study was designed further evaluate the mechanism of pulmonary vascular hyperpermeability in sheep with these injuries. Sheep were randomized to a sham-injured control group (n=6) or ALI/sepsis group (n=7). The sheep in the ALI/sepsis group received inhalation injury followed by instillation of Pseudomonas aeruginosa into the lungs. These groups were monitored for 24 h. Additional sheep (n=16) received the injury and lung tissue was harvested at different time points to measure lung wet/dry weight ratio, vascular endothelial growth factor (VEGF) mRNA and protein expression as well as 3-nitrotyrosine protein expression in lung homogenates. The injury induced severe deterioration in pulmonary gas exchange, increases in lung lymph flow and protein content, and lung water content (P<0.01 each). These alterations were associated with elevated lung and plasma nitrite/nitrate concentrations, increased tracheal blood flow, and enhanced VEGF mRNA and protein expression in lung tissue as well as enhanced 3-nitrotyrosine protein expression (P<0.05 each). This study describes the time course of pulmonary microvascular hyperpermeability in a clinical relevant large animal model and may improve the experimental design of future studies. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  4. FDG uptake in the fatty tissues of supraclavicular and the vascular structure of the lung hilum

    International Nuclear Information System (INIS)

    Dang Yaping; Liu Gang; Li Miao

    2004-01-01

    Full text: Supraclavicular region (SR) and lung hilum (LH) are common sites for lymph node metastases. A commonly reported site of non-malignant FDG uptake on PET imaging in the SR is muscular uptake. PET/CT offers a unique technique to correlate PET findings with CT anatomy in the SR and LH. We carried out this study to investigate FDG uptake in SR and LH to find out the exact tissues of FDG uptake. From September 2002 to March 2003, 147 consecutive patients imaged by FDG PET/CT whole-body scan (GE Discovery LS, CT attenuation correction, OSEM reconstruction) were retrospectively reviewed. The presence of abnormal FDG uptake on PET images in SR and LH regions was evaluated and the corresponding CT findings on the same regions were also assessed. Of the 147 patients, 8 cases (2M, 6F and mean age 44 years) were found with increased symmetrical FDG uptake in the regions of the lower neck and shoulder as well as costo-vertebral articulations. The positive rates were 2.1% and 11.3% for men and women respectively, and the average rate was 5.4%. However, no FDG uptake was seen in the greater muscular structures of the cervical or thoracic spine. FDG uptake was seen in the fatty tissue between the shoulder muscle and the dorsal thoracic wall, but not within the muscles itself. Five patients (3M, 2F, age 56-74 years, 3.4%) showed abnormal FDG uptake in LH, which were definitely localized in the vascular structure of the lung hilum by CT. Co-registered PET/CT imaging shows that the FDG uptake, though well known in the SR and LH regions, is not fully located in greater muscular structures and lymph nodes, but in the costo-vertebral articulation complex of the thoracic spine and fatty tissue of the shoulders as well as in the vascular structure of both lung hilum. The FDG uptake in the fatty tissue of the shoulders was mostly seen in women, while the uptake in vascular structure of the lung hilum were found in aged people. (author)

  5. Isoproterenol attenuates high vascular pressure-induced permeability increases in isolated rat lungs.

    Science.gov (United States)

    Parker, J C; Ivey, C L

    1997-12-01

    To separate the contributions of cellular and basement membrane components of the alveolar capillary barrier to the increased microvascular permeability induced by high pulmonary venous pressures (Ppv), we subjected isolated rat lungs to increases in Ppv, which increased capillary filtration coefficient (Kfc) without significant hemorrhage (31 cmH2O) and with obvious extravasation of red blood cells (43 cmH2O). Isoproterenol (20 microM) was infused in one group (Iso) to identify a reversible cellular component of injury, and residual blood volumes were measured to assess extravasation of red blood cells through ruptured basement membranes. In untreated lungs (High Ppv group), Kfc increased 6.2 +/- 1.3 and 38.3 +/- 15.2 times baseline during the 31 and 43 cmH2O Ppv states. In Iso lungs, Kfc was 36.2% (P Kfc increases at moderate Ppv, possibly because of an endothelial effect, but it did not affect red cell extravasation at higher vascular pressures.

  6. Evaluation of serum and pleural levels of endostatin and vascular epithelial growth factor in lung cancer patients with pleural effusion.

    Science.gov (United States)

    Zhang, Yu; Yu, Li-Ke; Xia, Ning

    2012-03-01

    To evaluate the diagnostic value of endostatin (ES), vascular endothelial growth factor (VEGF) and carcinoembryonic antigen (CEA) in both serum and pleural effusion of lung cancer patients. Levels of ES, VEGF and CEA in 52 malignant pleural effusion due to lung cancer and 50 patients with non-malignant disease were measured by using sandwich enzyme-linked immunosorbent assay and microparticle enzyme immunoassay. The ES, VEGF and CEA levels in pleural effusion and serum, and their ratio (F/S) were higher in lung cancer group than that in benign group, and the differences were statistically significant (Ppleural effusion due to lung cancer. In comparison with either single determination of concentration in serum or pleural fluid, the combined detection of two or three markers is of important clinical significance in the diagnosis of lung cancer. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  7. In vivo immunotherapy of lung cancer using cross-species reactive vascular endothelial growth factor nanobodies

    Directory of Open Access Journals (Sweden)

    vFatemeh Kazemi-Lomedasht v

    2017-05-01

    Full Text Available Objective(s: Lung cancer is the main leading cause of cancer death worldwide. Angiogenesis is the main step in proliferation and spreading of tumor cells. Targeting vascular endothelial growth factor (VEGF is an effective approach for inhibition of cancer angiogenesis. Nanobodies (NBs are a novel class of antibodies derived from the camel. Unique characteristics of Nbs like their small size and good penetration to tumor tissues makes them promising tools in drug development.  Development of NBs targeting both human and mouse VEGF is required for understanding their in vivo functions.  Therefore, development of cross-species reactive anti-VEGF Nbs for immunotherapy of lung cancer was the main aim of the current study. Materials and Methods: Here we developed NBs from Camelus dromedarius library with high specificity and binding affinity to both human and mouse VEGF. In vitro and In vivo function of developed NB was evaluated on human endothelial cells and lung epithelial tumor cells (TC-1. Results: A nanobody showed the highest affinity to human and mouse VEGF and potently inhibited VEGF in the ELISA experiment. Anti-VEGF NBs significantly inhibited in vitro human endothelial cell migration through blockade of VEGF (P=0.045. Anti-VEGF NBs also significantly inhibited in vivo TC-1 growth in a dose-dependent manner (P=0.001 and resulted in higher survival rate in the nanobody treated group Conclusion: These findings demonstrate the potential of anti-VEGF NBsin tumor growth inhibition and are promising as novel cancer therapeutic candidate.

  8. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Park, Sang Hyub [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  9. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-01-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  10. Lung salvage by pulmonary arterioplasty after vascular injury during video-assisted thoracoscopic surgical right upper lobectomy.

    Science.gov (United States)

    Petel, M R; Mahieu, J; Baste, J M

    2015-01-01

    Video Assisted Thoracoscopic Surgical (VATS) lobectomy is now considered feasible and safe. Nevertheless, thoracic surgeons need to be aware of dramatic complications that may occur during this procedure and how best to manage them. We report the case of a severe tear of the right pulmonary artery (PA) during elective VATS upper lobectomy, leading to emergency conversion to control the bleeding. Initial arterial repair was performed by end-to-end anastomosis. Early CT angiography showed thrombosis of the right PA due to anastomotic stenosis. We performed emergency pulmonary arterioplasty with a prosthetic patch to save the right lung. A CT scan days after surgical lung salvage confirmed the permeability of the PA and normal vascularization of the two remaining right lobes. We discuss herein this dramatic complication of VATS lobectomy, the viability of the lung after pulmonary arterial thrombosis, and advocate for early postoperative imaging after pulmonary arterioplasty. Copyright© Acta Chirurgica Belgica.

  11. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy.

    Science.gov (United States)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-11-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy.

  12. An Isolated Pulmonary Hematoma Mimicking a Lung Tumor as the Initial Finding of Vascular Ehlers-Danlos Syndrome

    International Nuclear Information System (INIS)

    Kang, Eun Ju; Lee, Ki Nam; Choi, Pil Jo; Ki, Chang Seok

    2012-01-01

    The vascular type of Ehlers-Danlos syndrome (vEDS) is an uncommon inherited disorder characterized by abnormalities in type III collagen, presenting itself as arterial dissection or rupture. We report a case of an isolated pulmonary hematoma mimicking a lung tumor in an 18-year-old man which turned out to be the initial finding of vEDS. Pneumothorax and hemothorax occurred repeatedly for 15 months following the surgical removal of the mass, and were treated by repeated left upper and lower lobectomy and thoracotomy. The diagnosis of vEDS was confirmed by pathologic and genetic studies.

  13. An Isolated Pulmonary Hematoma Mimicking a Lung Tumor as the Initial Finding of Vascular Ehlers-Danlos Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam; Choi, Pil Jo [Dept. of Radiology, Dong-A University Medicine Center, Dong-A University College of Medicine, Busan (Korea, Republic of); Ki, Chang Seok [Dept. of Radiology, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2012-09-15

    The vascular type of Ehlers-Danlos syndrome (vEDS) is an uncommon inherited disorder characterized by abnormalities in type III collagen, presenting itself as arterial dissection or rupture. We report a case of an isolated pulmonary hematoma mimicking a lung tumor in an 18-year-old man which turned out to be the initial finding of vEDS. Pneumothorax and hemothorax occurred repeatedly for 15 months following the surgical removal of the mass, and were treated by repeated left upper and lower lobectomy and thoracotomy. The diagnosis of vEDS was confirmed by pathologic and genetic studies.

  14. Lung matrix and vascular remodeling in mechanically ventilated elastin haploinsufficient newborn mice

    Science.gov (United States)

    Hilgendorff, Anne; Parai, Kakoli; Ertsey, Robert; Navarro, Edwin; Jain, Noopur; Carandang, Francis; Peterson, Joanna; Mokres, Lucia; Milla, Carlos; Preuss, Stefanie; Alcazar, Miguel Alejandre; Khan, Suleman; Masumi, Juliet; Ferreira-Tojais, Nancy; Mujahid, Sana; Starcher, Barry; Rabinovitch, Marlene

    2014-01-01

    Elastin plays a pivotal role in lung development. We therefore queried if elastin haploinsufficient newborn mice (Eln+/−) would exhibit abnormal lung structure and function related to modified extracellular matrix (ECM) composition. Because mechanical ventilation (MV) has been linked to dysregulated elastic fiber formation in the newborn lung, we also asked if elastin haploinsufficiency would accentuate lung growth arrest seen after prolonged MV of neonatal mice. We studied 5-day-old wild-type (Eln+/+) and Eln+/− littermates at baseline and after MV with air for 8–24 h. Lungs of unventilated Eln+/− mice contained ∼50% less elastin and ∼100% more collagen-1 and lysyl oxidase compared with Eln+/+ pups. Eln+/− lungs contained fewer capillaries than Eln+/+ lungs, without discernible differences in alveolar structure. In response to MV, lung tropoelastin and elastase activity increased in Eln+/+ neonates, whereas tropoelastin decreased and elastase activity was unchanged in Eln+/− mice. Fibrillin-1 protein increased in lungs of both groups during MV, more in Eln+/− than in Eln+/+ pups. In both groups, MV caused capillary loss, with larger and fewer alveoli compared with unventilated controls. Respiratory system elastance, which was less in unventilated Eln+/− compared with Eln+/+ mice, was similar in both groups after MV. These results suggest that elastin haploinsufficiency adversely impacts pulmonary angiogenesis and that MV dysregulates elastic fiber integrity, with further loss of lung capillaries, lung growth arrest, and impaired respiratory function in both Eln+/+ and Eln+/− mice. Paucity of lung capillaries in Eln+/− newborns might help explain subsequent development of pulmonary hypertension previously reported in adult Eln+/− mice. PMID:25539853

  15. Immunohistochemical examination of plexiform-like complex vascular lesions in the lungs of broiler chickens selected for susceptibility to idiopathic pulmonary arterial hypertension.

    Science.gov (United States)

    Hamal, Krishna R; Erf, Gisela F; Anthony, Nicholas B; Wideman, Robert F

    2012-01-01

    Idiopathic pulmonary arterial hypertension (IPAH) is a disease of unknown cause that is characterized by elevated pulmonary arterial pressure and pulmonary vascular resistance, and by extensive vascular remodelling. In human IPAH patients, remodelling of the pulmonary vasculature results in the formation of plexiform lesions in the terminal pulmonary arterioles. Various molecules are expressed in the human plexiform lesions, including alpha smooth muscle actin, von Willebrand factor, vascular endothelial growth factor, vascular endothelial growth factor receptor type 2, hypoxia inducible factor-1α, survivin, tenascin, collagen, fibronectin, and various immune/inflammatory cells such as, cytotoxic lymphocytes, B lymphocytes, MHC class II cells, and monocytes/macrophages are also present. Plexiform lesions rarely develop in the lungs of laboratory animals, but plexiform-like complex vascular lesions (CVL) do develop spontaneously in the lungs of broiler chickens from an IPAH-susceptible line. To examine angioproliferative and immune-system-related activities associated with CVL in broiler lungs, paraformaldehyde-fixed, paraffin-embedded lung sections from 8-week-old to 24-week-old broiler chickens were stained immunohistochemically using monoclonal or polyclonal antibodies specific for angioproliferative molecules and immune/inflammatory cells. The CVL in the lungs of broiler chickens exhibited positive staining for both angioproliferative molecules and immune/inflammatory cells. These observations combined with the close histological resemblance of broiler CVL to the plexiform lesions of human IPAH patients further validates chickens from our IPAH-susceptible line as an excellent animal model of spontaneous plexogenic arteriopathy.

  16. Acute tumor vascular effects following fractionated radiotherapy in human lung cancer: In vivo whole tumor assessment using volumetric perfusion computed tomography

    International Nuclear Information System (INIS)

    Ng, Q.-S.; Goh, Vicky; Milner, Jessica; Padhani, Anwar R.; Saunders, Michele I.; Hoskin, Peter J.

    2007-01-01

    Purpose: To quantitatively assess the in vivo acute vascular effects of fractionated radiotherapy for human non-small-cell lung cancer using volumetric perfusion computed tomography (CT). Methods and Materials: Sixteen patients with advanced non-small-cell lung cancer, undergoing palliative radiotherapy delivering 27 Gy in 6 fractions over 3 weeks, were scanned before treatment, and after the second (9 Gy), fourth (18 Gy), and sixth (27 Gy) radiation fraction. Using 16-detector CT, multiple sequential volumetric acquisitions were acquired after intravenous contrast agent injection. Measurements of vascular blood volume and permeability for the whole tumor volume were obtained. Vascular changes at the tumor periphery and center were also measured. Results: At baseline, lung tumor vascularity was spatially heterogeneous with the tumor rim showing a higher vascular blood volume and permeability than the center. After the second, fourth, and sixth fractions of radiotherapy, vascular blood volume increased by 31.6% (paired t test, p = 0.10), 49.3% (p = 0.034), and 44.6% (p = 0.0012) respectively at the tumor rim, and 16.4% (p = 0.29), 19.9% (p = 0.029), and 4.0% (p = 0.0050) respectively at the center of the tumor. After the second, fourth, and sixth fractions of radiotherapy, vessel permeability increased by 18.4% (p = 0.022), 44.8% (p = 0.0048), and 20.5% (p = 0.25) at the tumor rim. The increase in permeability at the tumor center was not significant after radiotherapy. Conclusion: Fractionated radiotherapy increases tumor vascular blood volume and permeability in human non-small-cell lung cancer. We have established the spatial distribution of vascular changes after radiotherapy; greater vascular changes were demonstrated at the tumor rim compared with the center

  17. Interstitial lung disease associated with collagen vascular disorders: disease quantification using a computer-aided diagnosis tool

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Dicken, V.; Kneitz, C.; Hoehmann, M.; Kenn, W.; Hahn, D.

    2009-01-01

    The purpose of this study was to evaluate a computer-aided diagnosis (CAD) tool compared to human observers in quantification of interstitial lung disease (ILD) in patients with collagen-vascular disorders. A total of 52 patients with rheumatoid arthritis (n=24), scleroderma (n=14) and systemic lupus erythematosus (n=14) underwent thin-section CT. Two independent observers assessed the extent of ILD (EoILD), reticulation (EoRet) and ground-glass opacity (EoGGO). CAD assessed EoILD twice. Pulmonary function tests were obtained. Statistical evaluation used 95% limits of agreement and linear regression analysis. CAD correlated well with diffusing capacity (DL CO ) (R=-0.531, P CO (R=-0.705, P CO and moderately with FVC (DL CO : R=-0.663; FVC: R=-0.436; P≤0.005). The CAD system is a promising tool for ILD quantification, showing close correlation with human observers and physiologic impairment. (orig.)

  18. The relationship between the percentage of lung shunting on Tc-99m macroaggregated albumin (Tc-99m MAA scan and the grade of hepatocellular carcinoma vascularity

    Directory of Open Access Journals (Sweden)

    Rania Refaat

    2014-06-01

    Conclusion: Tc-99m MAA scan is fundamental prior to Y-90 microsphere SIRT as it minimizes the risk of post-radioembolization complications, hence, enhancing the safety of Y-90 microsphere subsequent administration. Moreover, the percentage of lung shunting varies considerably among patients with HCC relying on the grade of tumor vascularity.

  19. On Probability Leakage

    OpenAIRE

    Briggs, William M.

    2012-01-01

    The probability leakage of model M with respect to evidence E is defined. Probability leakage is a kind of model error. It occurs when M implies that events $y$, which are impossible given E, have positive probability. Leakage does not imply model falsification. Models with probability leakage cannot be calibrated empirically. Regression models, which are ubiquitous in statistical practice, often evince probability leakage.

  20. Evidência de alterações de permeabilidade vascular na dengue: quando a dosagem de albumina sérica define o quadro? Plasma leakage detection in severe dengue: when serum albumin quantification plays a role?

    Directory of Open Access Journals (Sweden)

    Carlos A.A. Brito

    2007-04-01

    Full Text Available Evidência de extravasamento vascular decorrente do aumento da permeabilidade capilar caracteriza e diferencia febre hemorrágica da dengue. Este artigo avalia o valor de albumina sérica na detecção de alterações de permeabilidade vascular em casos de dengue. Quatorze pacientes diagnosticados com febre hemorrágica da dengue em dois hospitais privados em Recife, Brasil, entre janeiro e maio de 2002 foram seguidos com dosagens diárias de hematócrito e albumina sérica. Ultra-son e Raio X de tórax foram realizados. Oito (57% casos apresentaram hemoconcentração de 20% ou mais. Hipoalbuminemia foi detectado em dez (71% pacientes. Dosagem de albumina sérica aumentou a detecção de alterações de permeabilidade em seis (43% casos na qual a hemoconcentração foi inferior a 20% e os sintomas foram compatíveis com um a resposta imune exacerbada. Raio-X foi normal em todos os casos. A utilização, portanto, de dosagem de albumina sérica aumenta a sensibilidade de detecção de casos de febre hemorrágica da dengue.Evidence of vascular leakage due to increased capillary permeability characterizes and differentiates dengue hemorrhagic fever. This article assesses the value of serum albumin for detecting vascular permeability abnormalities in dengue cases. Fourteen patients diagnosed with dengue hemorrhagic fever at two private hospitals in Recife, Brazil, between January and May 2002 were followed up with daily hematocrit and serum albumin assays. Ultrasound scans and chest X-rays were also performed. Eight (57% of the cases presented hemoconcentration of 20% or more. Hypoalbuminemia was detected in ten patients (71%. Serum albumin assays increased the detection of permeability abnormalities in six cases (43% in which the hemoconcentration was less than 20% and the symptoms were compatible with an exacerbated immune response. The X-rays were normal in all cases. Thus, the use serum albumin quantification increased the sensitivity of dengue

  1. Human lung fibroblast-derived matrix facilitates vascular morphogenesis in 3D environment and enhances skin wound healing.

    Science.gov (United States)

    Du, Ping; Suhaeri, Muhammad; Ha, Sang Su; Oh, Seung Ja; Kim, Sang-Heon; Park, Kwideok

    2017-05-01

    Extracellular matrix (ECM) is crucial to many aspects of vascular morphogenesis and maintenance of vasculature function. Currently the recapitulation of angiogenic ECM microenvironment is still challenging, due mainly to its diverse components and complex organization. Here we investigate the angiogenic potential of human lung fibroblast-derived matrix (hFDM) in creating a three-dimensional (3D) vascular construct. hFDM was obtained via decellularization of in vitro cultured human lung fibroblasts and analyzed via immunofluorescence staining and ELISA, which detect multiple ECM macromolecules and angiogenic growth factors (GFs). Human umbilical vein endothelial cells (HUVECs) morphology was more elongated and better proliferative on hFDM than on gelatin-coated substrate. To prepare 3D construct, hFDM is collected, quantitatively analyzed, and incorporated in collagen hydrogel (Col) with HUVECs. Capillary-like structure (CLS) formation at 7day was significantly better with the groups containing higher doses of hFDM compared to the Col group (control). Moreover, the group (Col/hFDM/GFs) with both hFDM and angiogenic GFs (VEGF, bFGF, SDF-1) showed the synergistic activity on CLS formation and found much larger capillary lumen diameters with time. Further analysis of hFDM via angiogenesis antibody array kit reveals abundant biochemical cues, such as angiogenesis-related cytokines, GFs, and proteolytic enzymes. Significantly up-regulated expression of VE-cadherin and ECM-specific integrin subunits was also noticed in Col/hFDM/GFs. In addition, transplantation of Col/hFMD/GFs with HUVECs in skin wound model presents more effective re-epithelialization, many regenerated hair follicles, better transplanted cells viability, and advanced neovascularization. We believe that current system is a very promising platform for 3D vasculature construction in vitro and for cell delivery toward therapeutic applications in vivo. Functional 3D vasculature construction in vitro is still

  2. Antiangiogenic therapy in lung cancer: focus on vascular endothelial growth factor pathway.

    LENUS (Irish Health Repository)

    Korpanty, Grzegorz

    2010-01-01

    Lung cancer (LC) is a leading cause of death worldwide. Recent advances in chemotherapeutic agents have not yielded any significant improvement in the prognosis of patients with LC. The five-year survival rate for all combined disease stages remains about 15%. For this reason, new therapies such as those that inhibit tumor angiogenesis or block activity of growth factor receptors are of special interest in this group of patients. In this review we will summarize the most recent clinical data on biologic therapies that inhibit tumor angiogenesis in LC, focusing on those that are most clinically relevant.

  3. Improving Intensity-Based Lung CT Registration Accuracy Utilizing Vascular Information

    Directory of Open Access Journals (Sweden)

    Kunlin Cao

    2012-01-01

    Full Text Available Accurate pulmonary image registration is a challenging problem when the lungs have a deformation with large distance. In this work, we present a nonrigid volumetric registration algorithm to track lung motion between a pair of intrasubject CT images acquired at different inflation levels and introduce a new vesselness similarity cost that improves intensity-only registration. Volumetric CT datasets from six human subjects were used in this study. The performance of four intensity-only registration algorithms was compared with and without adding the vesselness similarity cost function. Matching accuracy was evaluated using landmarks, vessel tree, and fissure planes. The Jacobian determinant of the transformation was used to reveal the deformation pattern of local parenchymal tissue. The average matching error for intensity-only registration methods was on the order of 1 mm at landmarks and 1.5 mm on fissure planes. After adding the vesselness preserving cost function, the landmark and fissure positioning errors decreased approximately by 25% and 30%, respectively. The vesselness cost function effectively helped improve the registration accuracy in regions near thoracic cage and near the diaphragm for all the intensity-only registration algorithms tested and also helped produce more consistent and more reliable patterns of regional tissue deformation.

  4. Clinical Observation of Recombinant Human Vascular Endostatin Durative Transfusion Combined with Window Period Arterial Infusion Chemotherapy in the Treatment of 
Advanced Lung Squamous Carcinoma

    Directory of Open Access Journals (Sweden)

    Yuan LV

    2015-08-01

    Full Text Available Background and objective Lung cancer is one of the most common malignant tumors in China. The aim of this study is to observe the efficacy and safety of recombinant human vascular endostatin (endostar durative transfusion combined with window period arterial infusion chemotherapy in the treatment of advanced lung squamous carcinoma. Methods From February 2014 to January 2015, 10 cases of the cytological or histological pathology diagnosed stage IIIb - stage IV lung squamous carcinoma were treated with recombinant human vascular endostatin (30 mg/d durative transfusion combined with window period arterial infusion chemotherapy. Over the same period of 10 cases stage IIIb - stage IV lung squamous carcinoma patients for pure arterial perfusion chemotherapy were compared. Recombinant human vascular endostatin was durative transfused every 24 hours for 7 days in combination group, and in the 4th day of window period, the 10 patients were received artery infusion chemotherapy, using docetaxel combined with cisplatin. Pure treatment group received the same arterial perfusion chemotherapy regimen. 4 weeks was a cycle. 4 weeks after 2 cycles, to evaluate the short-term effects and the adverse drug reactions. Results 2 groups of patients were received 2 cycles treatments. The response rate (RR was 70.0%, and the disease control rate (DCR was 90.0% in the combination group; In the pure treatment group were 50.0%, 70.0% respectively, there were no statistically significant difference (P=0.650, 0.582. The adverse reactions of the treatment were mild, including level 1-2 of gastrointestinal reaction and blood toxicity, there were no statistically significant difference (P=0.999, P=0.628. In the combination group, 1 patient occurred level 1 of cardiac toxicity. Conclusion Recombinant human vascular endostatin durative transfusion combined with window period arterial infusion chemotherapy in the treatment of advanced lung squamous carcinoma could take a

  5. Lung

    International Nuclear Information System (INIS)

    DeNardo, G.L.; Blankenship, W.J.; Burdine, J.A. Jr.; DeNardo, S.J.

    1975-01-01

    At present no simple statement can be made relative to the role of radionuclidic lung studies in the pediatric population. It is safe to assume that they will be used with increasing frequency for research and clinical applications because of their sensitivity and ready applicability to the pediatric patient. Methods comparable to those used in adults can be used in children older than 4 years. In younger children, however, a single injection of 133 Xe in solution provides an index of both regional perfusion and ventilation which is easier to accomplish. This method is particularly valuable in infants and neonates because it is rapid, requires no patient cooperation, results in a very low radiation dose, and can be repeated in serial studies. Radionuclidic studies of ventilation and perfusion can be performed in almost all children if the pediatrician and the nuclear medicine specialist have motivation and ingenuity. S []ontaneous pulmonary vascular occlusive disease which occurs in infants and pulmonary emboli in children are easily detected using radionuclides. The pathophysiologic defects of pulmonary agenesis, bronchopulmonary sequestration, and foreign body aspiration may be demonstrated by these techniques. These techniques also appear to be useful in following patients with bronchial asthma, cystic fibrosis, congenital emphysema, and postinfection pulmonary abnormalities. (auth)

  6. Anti-Vascular Endothelial Growth Factor Antibody Suppresses ERK and NF-κB Activation in Ischemia-Reperfusion Lung Injury.

    Directory of Open Access Journals (Sweden)

    Chou-Chin Lan

    Full Text Available Ischemia-reperfusion (IR-induced acute lung injury (ALI is implicated in several clinical conditions like lung transplantation, acute pulmonary embolism after thrombolytic therapy, re-expansion of collapsed lung from pneumothorax or pleural effusion, cardiopulmonary bypass and etc. Because mortality remains high despite advanced medical care, prevention and treatment are important clinical issues for IR-induced ALI. Vascular endothelial growth factor (VEGF has a controversial role in ALI. We therefore conducted this study to determine the effects of anti-VEGF antibody in IR-induced ALI. In the current study, the IR-induced ALI was conducted in a rat model of isolated-perfused lung in situ in the chest. The animals were divided into the control, control + preconditioning anti-VEGF antibody (bevacizumab, 5mg/kg, IR, IR + preconditioning anti-VEGF antibody (1mg/kg, IR+ preconditioning anti-VEGF antibody (5mg/kg and IR+ post-IR anti-VEGF antibody (5mg/kg group. There were eight adult male Sprague-Dawley rats in each group. The IR caused significant pulmonary micro-vascular hyper-permeability, pulmonary edema, neutrophilic infiltration in lung tissues, increased tumor necrosis factor-α, and total protein concentrations in bronchoalveolar lavage fluid. VEGF and extracellular signal-regulated kinase (ERK were increased in IR-induced ALI. Administration of preconditioning anti-VEGF antibody significantly suppressed the VEGF and ERK expressions and attenuated the IR-induced lung injury. This study demonstrates the important role of VEGF in early IR-induced ALI. The beneficial effects of preconditioning anti-VEGF antibody in IR-induced ALI include the attenuation of lung injury, pro-inflammatory cytokines, and neutrophilic infiltration into the lung tissues.

  7. Autoradiographic observations of the induced vascular injuries by arachidonic acid in rabbit's brain and lung using 111In-oxine labeled platelets

    International Nuclear Information System (INIS)

    Fujimoto, Tsukasa; Fukushima, Yoshiharu; Suzuki, Hidenori; Kuroiwa, Kyoko; Tanoue, Kenjiro; Yamazaki, Hiroh.

    1985-01-01

    Autoradiography using 111 In-oxine labeled autologous platelets was performed to observe the behavior of platelets in induced vascular injury by activated platelets in rabbit's brain and lung. Cerebrovascular injuries were induced by injection of arachidonic acid (AA) (0.7 mg/kg) into right internal carotid artery. Fourteen animals were pretreated with antiplatelet drug, ticlopidine (200 mg/kg) and 10 were controls. Before the AA injection, 111 In-oxine (300 μCi) labeled platelets were injected intravenously. Evans blue was given as a marker of disturbances of blood brain barrier. Sixty min after the AA injection, brains were removed and autoradiographic and electron microscopic studies were done. In the nontreated animals and some of the treated animals whose platelet aggregability was not suppressed, blue staining were seen in the cerebral hemisphere of injection side and hot radioactivity in autoradiogram were revealed in corresponding area. In the treated animals whose platelet aggregability was remarkably suppressed, no or slight blue staining or radioactivity were recognized. Only in hot radioactive area, platelet thrombi and vascular injuries were seen. Vascular injuries of lung were produced by decompression after keeping animals under hyperbalic condition (6 atomosphere absolute for 40 min). Before this procedure, 111 In-oxine labeled platelets were injected. Lungs of both 4 control and 4 decompression sickness animals were removed and autoradiographic and lightmicroscopic observations were performed. In lungs of decompression sickness animals remarkable spotty high radioactivity and prominent platelet aggregates in the vessels were seen. These findings were not seen in control animals. Our results suggested important roles of platelets in induced vascular injuries. And this autoradiographic approach seemed to be quite useful for observation of platelet's behavior in injured vessels and evaluation of antiplatelet drugs. (author)

  8. Effects on Pulmonary Vascular Mechanics of Two Different Lung-Protective Ventilation Strategies in an Experimental Model of Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Santos, Arnoldo; Gomez-Peñalver, Eva; Monge-Garcia, M Ignacio; Retamal, Jaime; Borges, João Batista; Tusman, Gerardo; Hedenstierna, Goran; Larsson, Anders; Suarez-Sipmann, Fernando

    2017-11-01

    To compare the effects of two lung-protective ventilation strategies on pulmonary vascular mechanics in early acute respiratory distress syndrome. Experimental study. University animal research laboratory. Twelve pigs (30.8 ± 2.5 kg). Acute respiratory distress syndrome was induced by repeated lung lavages and injurious mechanical ventilation. Thereafter, animals were randomized to 4 hours ventilation according to the Acute Respiratory Distress Syndrome Network protocol or to an open lung approach strategy. Pressure and flow sensors placed at the pulmonary artery trunk allowed continuous assessment of pulmonary artery resistance, effective elastance, compliance, and reflected pressure waves. Respiratory mechanics and gas exchange data were collected. Acute respiratory distress syndrome led to pulmonary vascular mechanics deterioration. Four hours after randomization, pulmonary vascular mechanics was similar in Acute Respiratory Distress Syndrome Network and open lung approach: resistance (578 ± 252 vs 626 ± 153 dyn.s/cm; p = 0.714), effective elastance, (0.63 ± 0.22 vs 0.58 ± 0.17 mm Hg/mL; p = 0.710), compliance (1.19 ± 0.8 vs 1.50 ± 0.27 mL/mm Hg; p = 0.437), and reflection index (0.36 ± 0.04 vs 0.34 ± 0.09; p = 0.680). Open lung approach as compared to Acute Respiratory Distress Syndrome Network was associated with improved dynamic respiratory compliance (17.3 ± 2.6 vs 10.5 ± 1.3 mL/cm H2O; p mechanics similarly. The use of higher positive end-expiratory pressures in the open lung approach strategy did not worsen pulmonary vascular mechanics, improved lung mechanics, and gas exchange but at the expense of a lower cardiac index.

  9. Acute Systemic Infection with Dengue Virus Leads to Vascular Leakage and Death through Tumor Necrosis Factor-α and Tie2/Angiopoietin Signaling in Mice Lacking Type I and II Interferon Receptors.

    Science.gov (United States)

    Phanthanawiboon, Supranee; Limkittikul, Kriengsak; Sakai, Yusuke; Takakura, Nobuyuki; Saijo, Masayuki; Kurosu, Takeshi

    2016-01-01

    Severe dengue is caused by host responses to viral infection, but the pathogenesis remains unknown. This is, in part, due to the lack of suitable animal models. Here, we report a non-mouse-adapted low-passage DENV-3 clinical isolate, DV3P12/08, derived from recently infected patients. DV3P12/08 caused a lethal systemic infection in type I and II IFN receptor KO mice (IFN-α/β/γR KO mice), which have the C57/BL6 background. Infection with DV3P12/08 induced a cytokine storm, resulting in severe vascular leakage (mainly in the liver, kidney and intestine) and organ damage, leading to extensive hemorrhage and rapid death. DV3P12/08 infection triggered the release of large amounts of TNF-α, IL-6, and MCP-1. Treatment with a neutralizing anti-TNF-α antibody (Ab) extended survival and reduced liver damage without affecting virus production. Anti-IL-6 neutralizing Ab partly prolonged mouse survival. The anti-TNF-α Ab suppressed IL-6, MCP-1, and IFN-γ levels, suggesting that the severe response to infection was triggered by TNF-α. High levels of TNF-α mRNA were expressed in the liver and kidneys, but not in the small intestine, of infected mice. Conversely, high levels of IL-6 mRNA were expressed in the intestine. Importantly, treatment with Angiopoietin-1, which is known to stabilize blood vessels, prolonged the survival of DV3P12/08-infected mice. Taken together, the results suggest that an increased level of TNF-α together with concomitant upregulation of Tie2/Angiopoietin signaling have critical roles in severe dengue infection.

  10. Interstitial lung disease associated with collagen vascular disorders: disease quantification using a computer-aided diagnosis tool

    Energy Technology Data Exchange (ETDEWEB)

    Marten, K.; Engelke, C. [University Hospital of Goettingen, Department of Radiology, Goettingen (Germany); Dicken, V. [MeVis Research GmbH, Bremen (Germany); Kneitz, C. [University Hospital of Wuerzburg, Dept. of Rheumatology and Clinical Immunology, Medizinische Klinik and Poliklinik, Wuerzburg (Germany); Hoehmann, M.; Kenn, W.; Hahn, D. [University Hospital of Wuerzburg, Department of Radiology, Wuerzburg (Germany)

    2009-02-15

    The purpose of this study was to evaluate a computer-aided diagnosis (CAD) tool compared to human observers in quantification of interstitial lung disease (ILD) in patients with collagen-vascular disorders. A total of 52 patients with rheumatoid arthritis (n=24), scleroderma (n=14) and systemic lupus erythematosus (n=14) underwent thin-section CT. Two independent observers assessed the extent of ILD (EoILD), reticulation (EoRet) and ground-glass opacity (EoGGO). CAD assessed EoILD twice. Pulmonary function tests were obtained. Statistical evaluation used 95% limits of agreement and linear regression analysis. CAD correlated well with diffusing capacity (DL{sub CO}) (R=-0.531, P<0.0001) and moderately with forced vital capacity (FVC) (R=-0.483, P=0.0008). There was close correlation between CAD and the readers (EoILD vs. CAD: R=0.716, P<0.0001; EoRet vs. CAD: R=0.69, P<0.0001). Subgroup analysis including patients with minimal EoGGO (<15%) strengthened the correlations between CAD and the readers, readers and PFT, and CAD and PFT. EoILD by readers correlated strongly with DL{sub CO} (R=-0.705, P<0.0001) and moderately with FVC (R=-0.559, P=0.0002). EoRet correlated closely with DL{sub CO} and moderately with FVC (DL{sub CO}: R=-0.663; FVC: R=-0.436; P{<=}0.005). The CAD system is a promising tool for ILD quantification, showing close correlation with human observers and physiologic impairment. (orig.)

  11. Bioinformatics Analyses of the Role of Vascular Endothelial Growth Factor in Patients with Non-Small Cell Lung Cancer.

    Directory of Open Access Journals (Sweden)

    Ying Wang

    Full Text Available This study was aimed to identify the expression pattern of vascular endothelial growth factor (VEGF in non-small cell lung cancer (NSCLC and to explore its potential correlation with the progression of NSCLC.Gene expression profile GSE39345 was downloaded from the Gene Expression Omnibus database. Twenty healthy controls and 32 NSCLC samples before chemotherapy were analyzed to identify the differentially expressed genes (DEGs. Then pathway enrichment analysis of the DEGs was performed and protein-protein interaction networks were constructed. Particularly, VEGF genes and the VEGF signaling pathway were analyzed. The sub-network was constructed followed by functional enrichment analysis.Total 1666 up-regulated and 1542 down-regulated DEGs were identified. The down-regulated DEGs were mainly enriched in the pathways associated with cancer. VEGFA and VEGFB were found to be the initiating factor of VEGF signaling pathway. In addition, in the epidermal growth factor receptor (EGFR, VEGFA and VEGFB associated sub-network, kinase insert domain receptor (KDR, fibronectin 1 (FN1, transforming growth factor beta induced (TGFBI and proliferating cell nuclear antigen (PCNA were found to interact with at least two of the three hub genes. The DEGs in this sub-network were mainly enriched in Gene Ontology terms related to cell proliferation.EGFR, KDR, FN1, TGFBI and PCNA may interact with VEGFA to play important roles in NSCLC tumorigenesis. These genes and corresponding proteins may have the potential to be used as the targets for either diagnosis or treatment of patients with NSCLC.

  12. Imbalance between vascular endothelial growth factor and endostatin correlates with the prognosis of operable non-small cell lung cancer.

    Science.gov (United States)

    Hu, Y; Hu, M-m; Shi, G-L; Han, Y; Li, B-L

    2014-09-01

    Angiogenesis is regulated by a balance of pro-angiogenic and anti-angiogenic factors. Vascular endothelial growth factor (VEGF) and endostatin respectively represents a frequent component of inducers and inhibitors in the process of angiogenesis. The ratio of VEGF/endostatin may reflect the balance of angiogenic switch. This study aimed to determine whether an imbalance between VEGF/endostatin exists in operable non-small cell lung cancer (NSCLC) patients and to assess the correlation, if any, between the imbalance and the prognosis. Preoperative serum levels of VEGF and endostatin were simultaneously determined by quantitiative enzyme-linked immunosorbent assay (ELISA) and the ratio of them was calculated among 98 NSCLC patients and 51 healthy controls. The relationship between these factors and clinicopathological features, including prognosis, was examined. The ratio of VEGF/endostatin levels was significantly higher in operable NSCLC patients [median, 10.4; interquartile range (IQR), 5.9-19.8] than in normal controls [median, 5.1; IQR, 3.3-9.7] (P = 0.002). While the ratio in patients who were still alive for more than 60 months was 8.3 (IQR, 4.3-17.9), the ratio in those who died was 12.9 (IQR, 8.0-22.1) (p = 0.017). In subgroup analysis of patients with pathological stage N0, there was a statistically significant increase of the survival time in the group with a lower ratio than in the group with a higher ratio (p = 0.032). Multivariate analysis confirmed that the VEGF/endostatin ratio was an independent prognostic factor (p = 0.018). There was an imbalance between VEGF and endostatin in serum of operable NSCLC patients. The imbalance correlated with the prognosis of operable NSCLC. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Expression of neuroimmune semaphorins 4A and 4D and their receptors in the lung is enhanced by allergen and vascular endothelial growth factor

    Directory of Open Access Journals (Sweden)

    Keegan Achsah D

    2011-05-01

    Full Text Available Abstract Background Semaphorins were originally identified as molecules regulating a functional activity of axons in the nervous system. Sema4A and Sema4D were the first semaphorins found to be expressed on immune cells and were termed "immune semaphorins". It is known that Sema4A and Sema4D bind Tim-2 and CD72 expressed on leukocytes and PlexinD1 and B1 present on non-immune cells. These neuroimmune semaphorins and their receptors have been shown to play critical roles in many physiological and pathological processes including neuronal development, immune response regulation, cancer, autoimmune, cardiovascular, renal, and infectious diseases. However, the expression and regulation of Sema4A, Sema4D, and their receptors in normal and allergic lungs is undefined. Results Allergen treatment and lung-specific vascular endothelial growth factor (VEGF expression induced asthma-like pathologies in the murine lungs. These experimental models of allergic airway inflammation were used for the expression analysis of immune semaphorins and their receptors employing immunohistochemistry and flow cytometry techniques. We found that besides accessory-like cells, Sema4A was also detected on bronchial epithelial and smooth muscle cells, whereas Sema4D expression was high on immune cells such as T and B lymphocytes. Surprisingly, under inflammation various cell types including macrophages, lymphocytes, and granulocytes in the lung expressed Tim-2, a previously defined marker for Th2 cells. CD72 was found on lung immune, inflammatory, and epithelial cells. Bronchial epithelial cells were positive for both plexins, whereas some endothelial cells selectively expressed Plexin D1. Plexin B1 expression was also detected on lung DC. Both allergen and VEGF upregulated the expression of neuroimmune semaphorins and their receptors in the lung tissue. However, the lung tissue Sema4A-Tim2 expression was rather weak, whereas Sema4D-CD72 ligand-receptor pair was vastly

  14. Isolation of a cDNA for a Growth Factor of Vascular Endothelial Cells from Human Lung Cancer Cells: Its Identity with Insulin‐like Growth Factor II

    Science.gov (United States)

    Hagiwara, Koichi; Kobayashi, Tatsuo; Tobita, Masato; Kikyo, Nobuaki; Yazaki, Yoshio

    1995-01-01

    We have found growth‐promoting activity for vascular endothelial cells in the conditioned medium of a human lung cancer cell line, T3M‐11. Purification and characterization of the growth‐promoting activity have been carried out using ammonium sulfate precipitation and gel‐exclusion chromatography. The activity migrated as a single peak just after ribonuclease. It did not bind to a heparin affinity column. These results suggest that the activity is not a heparin‐binding growth factor (including fibroblast growth factors) or a vascular endothelial growth factor. To identify the molecule exhibiting the growth‐promoting activity, a cDNA encoding the growth factor was isolated through functional expression cloning in COS‐1 cells from a cDNA library prepared from T3M‐11 cells. The nucleotide sequence encoded by the cDNA proved to be identical with that of insulin‐like growth factor II. PMID:7730145

  15. Vascular and lung function related to ultrafine and fine particles exposure assessed by personal and indoor monitoring: a cross-sectional study

    DEFF Research Database (Denmark)

    Olsen, Yulia; Karottki, Dorina Gabriela; Jensen, Ditte Marie

    2014-01-01

    -related effects. Methods: Associations between vascular and lung function, inflammation markers and exposure in terms of particle number concentration (PNC; d = 10-300 nm) were studied in a cross-sectional design with personal and home indoor monitoring in the Western Copenhagen Area, Denmark. During 48-h, PNC...... and PM2.5 were monitored in living rooms of 60 homes with 81 non-smoking subjects (30-75 years old), 59 of whom carried personal monitors both when at home and away from home. We measured lung function in terms of the FEV1/FVC ratio, microvascular function (MVF) and pulse amplitude by digital artery...... tonometry, blood pressure and biomarkers of inflammation including C-reactive protein, and leukocyte counts with subdivision in neutrophils, eosinophils, monocytes, and lymphocytes in blood. Results: PNC from personal and stationary home monitoring showed weak correlation (r = 0.15, p = 0.24). Personal UFP...

  16. Land-use Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  17. Data leakage quantification

    NARCIS (Netherlands)

    Vavilis, S.; Petkovic, M.; Zannone, N.; Atluri, V.; Pernul, G.

    2014-01-01

    The detection and handling of data leakages is becoming a critical issue for organizations. To this end, data leakage solutions are usually employed by organizations to monitor network traffic and the use of portable storage devices. These solutions often produce a large number of alerts, whose

  18. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  19. ATR confinement leakage determination

    International Nuclear Information System (INIS)

    Kuan, P.; Buescher, B.J.

    1998-01-01

    The air leakage rate from the Advanced Test Reactor (ATR) confinement is an important parameter in estimating hypothesized accidental releases of radiation to the environment. The leakage rate must be determined periodically to assure that the confinement has not degraded with time and such determination is one of the technical safety requirements of ATR operation. This paper reviews the methods of confinement leakage determination and presents an analysis of leakage determination under windy conditions, which can complicate the interpretation of the determined leakage rates. The paper also presents results of analyses of building air exchange under windy conditions. High wind can enhance air exchange and this could increase the release rates of radioisotopes following an accident

  20. Radioactivity leakage monitoring system

    International Nuclear Information System (INIS)

    Nakajima, Takuichiro; Noguchi, Noboru.

    1982-01-01

    Purpose: To obtain a device for detecting the leakage ratio of a primary coolant by utilizing the variation in the radioactivity concentration in a reactor container when the coolant is leaked. Constitution: A measurement signal is produced from a radioactivity measuring instrument, and is continuously input to a malfunction discriminator. The discriminator inputs a measurement signal to a concentration variation discriminator when the malfunction is recognized and simultaneously inputs a measurement starting time from the inputting time to a concentration measuring instrument. On the other hand, reactor water radioactivity concentration data obtained by sampling the primary coolant is input to a concentration variation computing device. A comparator obtains the ratio of the measurement signal from the measuring instrument and the computed data signal from the computing device at the same time and hence the leakage rate, indicates the average leakage rate by averaging the leakage rate signals and also indicates the total leakage amount. (Yoshihara, H.)

  1. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  2. Universal leakage elimination

    International Nuclear Information System (INIS)

    Byrd, Mark S.; Lidar, Daniel A.; Wu, L.-A.; Zanardi, Paolo

    2005-01-01

    'Leakage' errors are particularly serious errors which couple states within a code subspace to states outside of that subspace, thus destroying the error protection benefit afforded by an encoded state. We generalize an earlier method for producing leakage elimination decoupling operations and examine the effects of the leakage eliminating operations on decoherence-free or noiseless subsystems which encode one logical, or protected qubit into three or four qubits. We find that by eliminating a large class of leakage errors, under some circumstances, we can create the conditions for a decoherence-free evolution. In other cases we identify a combined decoherence-free and quantum error correcting code which could eliminate errors in solid-state qubits with anisotropic exchange interaction Hamiltonians and enable universal quantum computing with only these interactions

  3. Coregulation of glucose uptake and vascular endothelial growth factor (VEGF) in two small-cell lung cancer (SCLC) sublines in vivo and in vitro

    DEFF Research Database (Denmark)

    Pedersen, M W; Holm, S; Lund, E L

    2001-01-01

    We examined the relationship between (18)F- labeled 2-fluro-2-deoxy-d-glucose (FDG) uptake, and expression of glucose transporters (GLUTs) in two human small-cell lung cancer (SCLC) lines CPH 54A and CPH 54B. Changes in the expression of GLUTs and vascular endothelial growth factor (VEGF) during 12......-, 18-, and 24 hours of severe hypoxia in vivo (xenografts) and in vitro (cell cultures) were recorded for both tumor lines. The two SCLC lines are subpopulations of the same patient tumor. In spite of their common genomic origin they represent consistently different metabolic and microenvironmental...... phenotypes as well as treatment sensitivities. There were higher levels of Glut-1 protein in 54B and a correspondingly higher FDG uptake in this tumor line (P

  4. Morphological appearance, content of extracellular matrix and vascular density of lung metastases predicts permissiveness to infiltration by adoptively transferred natural killer and T cells

    DEFF Research Database (Denmark)

    Yang, Q.; Goding, S.; Hagenaars, M.

    2006-01-01

    . Analyses of tumors for extracellular matrix (ECM) components and PECAM-1(+) vasculature, revealed that the I-R lesions are hypovascularized and contain very little laminin, collagen and fibronectin. In contrast, the I-P loose tumors are well-vascularized and they contain high amounts of ECM components....... Interestingly, the distribution pattern of ECM components in the I-P loose tumors is almost identical to that of the normal lung tissue, indicating that these tumors develop around the alveolar walls which provide the loose tumors with both a supporting tissue and a rich blood supply. In conclusion, tumor...... infiltration by activated NK and T cells correlates with the presence of ECM components and PECAM-1(+) vasculature in the malignant tissue. Thus, analysis of the distribution of ECM and vasculature in tumor biopsies may help select patients most likely to benefit from cellular adoptive immunotherapy....

  5. Coolant leakage detecting device

    International Nuclear Information System (INIS)

    Yamauchi, Kiyoshi; Kawai, Katsunori; Ishihara, Yoshinao.

    1995-01-01

    The device of the present invention judges an amount of leakage of primary coolants of a PWR power plant at high speed. Namely, a mass of coolants contained in a pressurizer, a volume controlling tank and loop regions is obtained based on a preset relational formula and signals of each of process amount, summed up to determine the total mass of coolants for every period of time. The amount of leakage for every period of time is calculated by a formula of Karman's filter based on the total mass of the primary coolants for every predetermined period of time, and displays it on CRT. The Karman's filter is formed on every formula for several kinds of states formed based on the preset amount of the leakage, to calculate forecasting values for every mass of coolants. An adaptable probability for every preset leakage amount is determined based on the difference between the forecast value and the observed value and the scattering thereof. The adaptable probability is compared with a predetermined threshold value, which is displayed on the CRT. This device enables earlier detection of leakage and identification of minute leakage amount as compared with the prior device. (I.S.)

  6. The clinical usefulness of extravascular lung water and pulmonary vascular permeability index to diagnose and characterize pulmonary edema: a prospective multicenter study on the quantitative differential diagnostic definition for acute lung injury/acute respiratory distress syndrome

    Science.gov (United States)

    2012-01-01

    Introduction Acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) is characterized by features other than increased pulmonary vascular permeability. Pulmonary vascular permeability combined with increased extravascular lung water content has been considered a quantitative diagnostic criterion of ALI/ARDS. This prospective, multi-institutional, observational study aimed to clarify the clinical pathophysiological features of ALI/ARDS and establish its quantitative diagnostic criteria. Methods The extravascular lung water index (EVLWI) and the pulmonary vascular permeability index (PVPI) were measured using the transpulmonary thermodilution method in 266 patients with PaO2/FiO2 ratio ≤ 300 mmHg and bilateral infiltration on chest radiography, in 23 ICUs of academic tertiary referral hospitals. Pulmonary edema was defined as EVLWI ≥ 10 ml/kg. Three experts retrospectively determined the pathophysiological features of respiratory insufficiency by considering the patients' history, clinical presentation, chest computed tomography and radiography, echocardiography, EVLWI and brain natriuretic peptide level, and the time course of all preceding findings under systemic and respiratory therapy. Results Patients were divided into the following three categories on the basis of the pathophysiological diagnostic differentiation of respiratory insufficiency: ALI/ARDS, cardiogenic edema, and pleural effusion with atelectasis, which were noted in 207 patients, 26 patients, and 33 patients, respectively. EVLWI was greater in ALI/ARDS and cardiogenic edema patients than in patients with pleural effusion with atelectasis (18.5 ± 6.8, 14.4 ± 4.0, and 8.3 ± 2.1, respectively; P edema or pleural effusion with atelectasis patients (3.2 ± 1.4, 2.0 ± 0.8, and 1.6 ± 0.5; P edema patients. A PVPI value of 2.6 to 2.85 provided a definitive diagnosis of ALI/ARDS (specificity, 0.90 to 0.95), and a value < 1.7 ruled out an ALI/ARDS diagnosis (specificity, 0.95). Conclusion

  7. Enlarged pulmonary artery is predicted by vascular injury biomarkers and is associated with WTC-Lung Injury in exposed fire fighters: a case–control study

    Science.gov (United States)

    Schenck, Edward J; Echevarria, Ghislaine C; Girvin, Francis G; Kwon, Sophia; Comfort, Ashley L; Rom, William N; Prezant, David J; Weiden, Michael D; Nolan, Anna

    2014-01-01

    Objectives We hypothesise that there is an association between an elevated pulmonary artery/aorta (PA/A) and World Trade Center-Lung Injury (WTC-LI). We assessed if serum vascular disease biomarkers were predictive of an elevated PA/A. Design Retrospective case-cohort analysis of thoracic CT scans of WTC-exposed firefighters who were symptomatic between 9/12/2001 and 3/10/2008. Quantification of vascular-associated biomarkers from serum collected within 200 days of exposure. Setting Urban tertiary care centre and occupational healthcare centre. Participants Male never-smoking firefighters with accurate pre-9/11 forced expiratory volume in 1 s (FEV1) ≥75%, serum sampled ≤200 days of exposure was the baseline cohort (n=801). A subcohort (n=97) with available CT scans and serum biomarkers was identified. WTC-LI was defined as FEV1≤77% at the subspecialty pulmonary evaluation (n=34) and compared with controls (n=63) to determine the associated PA/A ratio. The subcohort was restratified based on PA/A≥0.92 (n=38) and PA/A<0.92(n=59) to determine serum vascular biomarkers that were predictive of this vasculopathy. Outcome measures The primary outcome of this study was to identify a PA/A ratio in a cohort of individuals exposed to WTC dust that was associated with WTC-LI. The secondary outcome was to identify serum biomarkers predictive of the PA/A ratio using logistic regression. Results PA/A≥0.92 was associated with WTC-LI, OR of 4.02 (95% CI 1.21 to 13.41; p=0.023) when adjusted for exposure, body mass index and age at CT. Elevated macrophage derived chemokine and soluble endothelial selectin were predictive of PA/A≥0.92, (OR, 95% CI 2.08, 1.05 to 4.11, p=0.036; 1.33, 1.06 to 1.68, p=0.016, respectively), while the increased total plasminogen activator inhibitor 1 was predictive of not having PA/A≥0.92 (OR 0.88, 0.79 to 0.98; p=0.024). Conclusions Elevated PA/A was associated with WTC-LI. Development of an elevated PA/A was predicted by biomarkers of

  8. Coolant leakage detection device

    International Nuclear Information System (INIS)

    Ito, Takao.

    1983-01-01

    Purpose: To surely detect the coolant leakage at a time when the leakage amount is still low in the intra-reactor inlet pipeway of FBR type reactor. Constitution: Outside of the intra-reactor inlet piping for introducing coolants at low temperature into a reactor core, an outer closure pipe is furnished. The upper end of the outer closure pipe opens above the liquid level of the coolants in the reactor, and a thermocouple is inserted to the opening of the upper end. In such a structure, if the coolants in the in-reactor piping should leak to the outer closure pipe, coolants over-flows from the opening thereof, at which the thermocouple detects the temperature of the coolants at a low temperature, thereby enabling to detect the leakage of the coolants at a time when it is still low. (Kamimura, M.)

  9. Channel follower leakage restrictor

    International Nuclear Information System (INIS)

    Williamson, H.E.; Smith, B.A.

    1977-01-01

    An improved means is provided to control coolant leakage between the flow channel and the lower tie plate of a nuclear fuel assembly. The means includes an opening in the lower tie plate and a movable element adjacent thereto. The coolant pressure within the tie plate biases the movable means toward the inner surface of the surrounding flow channel to compensate for any movement of the flow channel away from the lower tie plate to thereby control the leakage of coolant flow from the fuel assemblies to the spaces among the fuel assemblies of the core. 9 figures

  10. Pathophysiological Consequences of a Break in S1P1-Dependent Homeostasis of Vascular Permeability Revealed by S1P1 Competitive Antagonism.

    Science.gov (United States)

    Bigaud, Marc; Dincer, Zuhal; Bollbuck, Birgit; Dawson, Janet; Beckmann, Nicolau; Beerli, Christian; Fishli-Cavelti, Gina; Nahler, Michaela; Angst, Daniela; Janser, Philipp; Otto, Heike; Rosner, Elisabeth; Hersperger, Rene; Bruns, Christian; Quancard, Jean

    2016-01-01

    Homeostasis of vascular barriers depends upon sphingosine 1-phosphate (S1P) signaling via the S1P1 receptor. Accordingly, S1P1 competitive antagonism is known to reduce vascular barrier integrity with still unclear pathophysiological consequences. This was explored in the present study using NIBR-0213, a potent and selective S1P1 competitive antagonist. NIBR-0213 was tolerated at the efficacious oral dose of 30 mg/kg BID in the rat adjuvant-induced arthritis (AiA) model, with no sign of labored breathing. However, it induced dose-dependent acute vascular pulmonary leakage and pleural effusion that fully resolved within 3-4 days, as evidenced by MRI monitoring. At the supra-maximal oral dose of 300 mg/kg QD, NIBR-0213 impaired lung function (with increased breathing rate and reduced tidal volume) within the first 24 hrs. Two weeks of NIBR-0213 oral dosing at 30, 100 and 300 mg/kg QD induced moderate pulmonary changes, characterized by alveolar wall thickening, macrophage accumulation, fibrosis, micro-hemorrhage, edema and necrosis. In addition to this picture of chronic inflammation, perivascular edema and myofiber degeneration observed in the heart were also indicative of vascular leakage and its consequences. Overall, these observations suggest that, in the rat, the lung is the main target organ for the S1P1 competitive antagonism-induced acute vascular leakage, which appears first as transient and asymptomatic but could lead, upon chronic dosing, to lung remodeling with functional impairments. Hence, this not only raises the question of organ specificity in the homeostasis of vascular barriers, but also provides insight into the pre-clinical evaluation of a potential safety window for S1P1 competitive antagonists as drug candidates.

  11. Assessing Agulhas leakage

    NARCIS (Netherlands)

    van Sebille, E.

    2009-01-01

    Agulhas leakage, the water that flows from the Indian Ocean to the Atlantic Ocean, plays an important role in the circulation of the Atlantic Ocean. The magnitude of this flux of warm and saline Indian Ocean water into the much colder and fresher Atlantic Ocean can be related to the strength of the

  12. Roxby Downs water leakage

    International Nuclear Information System (INIS)

    1996-01-01

    The Environment, Resource and development Committee has been asked by Parliament to examine 'a massive leakage of water at Roxby Downs' and to make recommendations 'as to further action'. It has also been specifically asked to comment on 'the desirability of the Department of Mines and Energy having prime responsibility for environmental matters in relation to mining operations'. This report begins with a description of the Olympic Dam operations near Roxby Downs and with a brief overview of the regulations controlling those operations. The site of the leakage the Olympic Dam tailings retention system is then described in greater detail. Part 3 describes how the system was originally designed, modified and approved. It ends with a series of findings about the adequacy of the original design (including the monitoring systems built into it) and of the approvals process. Recommendations are then made about how future approvals should be handled. Part 4 of the report outlines how the tailings retention system was built and operated and how the massive leakage from it was detected and reported. Findings about the adequacy of the management of the system and about the initial reactions to the leakage are then made, together with recommendations designed to improve future management of the system. 25 refs., 15 figs

  13. JAK2 mediates lung fibrosis, pulmonary vascular remodelling and hypertension in idiopathic pulmonary fibrosis: an experimental study.

    Science.gov (United States)

    Milara, Javier; Ballester, Beatriz; Morell, Anselm; Ortiz, José L; Escrivá, Juan; Fernández, Estrella; Perez-Vizcaino, Francisco; Cogolludo, Angel; Pastor, Enrique; Artigues, Enrique; Morcillo, Esteban; Cortijo, Julio

    2018-06-01

    Pulmonary hypertension (PH) is a common disorder in patients with idiopathic pulmonary fibrosis (IPF) and portends a poor prognosis. Recent studies using vasodilators approved for PH have failed in improving IPF mainly due to ventilation ( V )/perfusion ( Q ) mismatching and oxygen desaturation. Janus kinase type 2 (JAK2) is a non-receptor tyrosine kinase activated by a broad spectrum of profibrotic and vasoactive mediators, but its role in PH associated to PH is unknown. The study of JAK2 as potential target to treat PH in IPF. JAK2 expression was increased in pulmonary arteries (PAs) from IPF (n=10; 1.93-fold; P=0.0011) and IPF+PH (n=9; 2.65-fold; Ppulmonary artery endothelial cells (HPAECs) and human pulmonary artery smooth muscle cells (HPASMCs) from patients with IPF in vitro treated with the JAK2 inhibitor JSI-124 or siRNA-JAK2 and stimulated with transforming growth factor beta. Both JSI-124 and siRNA-JAK2 inhibited the HPAEC to mesenchymal transition and the HPASMCs to myofibroblast transition and proliferation. JAK2 inhibition induced small PA relaxation in precision-cut lung slice experiments. PA relaxation was dependent of the large conductance calcium-activated potassium channel (BK Ca ). JAK2 inhibition activated BK Ca channels and reduced intracellular Ca 2+ . JSI-124 1 mg/kg/day, reduced bleomycin-induced lung fibrosis, PA remodelling, right ventricular hypertrophy, PA hypertension and V / Q mismatching in rats. The animal studies followed the ARRIVE guidelines. JAK2 participates in PA remodelling and tension and may be an attractive target to treat IPF associated to PH. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Autophagy inhibitor 3-methyladenine protects against endothelial cell barrier dysfunction in acute lung injury.

    Science.gov (United States)

    Slavin, Spencer A; Leonard, Antony; Grose, Valerie; Fazal, Fabeha; Rahman, Arshad

    2018-03-01

    Autophagy is an evolutionarily conserved cellular process that facilitates the continuous recycling of intracellular components (organelles and proteins) and provides an alternative source of energy when nutrients are scarce. Recent studies have implicated autophagy in many disorders, including pulmonary diseases. However, the role of autophagy in endothelial cell (EC) barrier dysfunction and its relevance in the context of acute lung injury (ALI) remain uncertain. Here, we provide evidence that autophagy is a critical component of EC barrier disruption in ALI. Using an aerosolized bacterial lipopolysaccharide (LPS) inhalation mouse model of ALI, we found that administration of the autophagy inhibitor 3-methyladenine (3-MA), either prophylactically or therapeutically, markedly reduced lung vascular leakage and tissue edema. 3-MA was also effective in reducing the levels of proinflammatory mediators and lung neutrophil sequestration induced by LPS. To test the possibility that autophagy in EC could contribute to lung vascular injury, we addressed its role in the mechanism of EC barrier disruption. Knockdown of ATG5, an essential regulator of autophagy, attenuated thrombin-induced EC barrier disruption, confirming the involvement of autophagy in the response. Similarly, exposure of cells to 3-MA, either before or after thrombin, protected against EC barrier dysfunction by inhibiting the cleavage and loss of vascular endothelial cadherin at adherens junctions, as well as formation of actin stress fibers. 3-MA also reversed LPS-induced EC barrier disruption. Together, these data imply a role of autophagy in lung vascular injury and reveal the protective and therapeutic utility of 3-MA against ALI.

  15. Colorectal Anastomotic Leakage: New perspectives

    NARCIS (Netherlands)

    F. Daams (Freek)

    2014-01-01

    markdownabstract__Abstract__ This thesis provides new perspectives on colorectal anastomotic leakages. In both experimental and clinical studies, aspects of prevention, early identification, treatment and consequences of anastomotic leakage are discussed.

  16. Leakage radiation interference microscopy.

    Science.gov (United States)

    Descrovi, Emiliano; Barakat, Elsie; Angelini, Angelo; Munzert, Peter; De Leo, Natascia; Boarino, Luca; Giorgis, Fabrizio; Herzig, Hans Peter

    2013-09-01

    We present a proof of principle for a new imaging technique combining leakage radiation microscopy with high-resolution interference microscopy. By using oil immersion optics it is demonstrated that amplitude and phase can be retrieved from optical fields, which are evanescent in air. This technique is illustratively applied for mapping a surface mode propagating onto a planar dielectric multilayer on a thin glass substrate. The surface mode propagation constant estimated after Fourier transformation of the measured complex field is well matched with an independent measurement based on back focal plane imaging.

  17. Leakage resilient password systems

    CERN Document Server

    Li, Yingjiu; Deng, Robert H

    2015-01-01

    This book investigates tradeoff between security and usability in designing leakage resilient password systems (LRP) and introduces two practical LRP systems named Cover Pad and ShadowKey. It demonstrates that existing LRP systems are subject to both brute force attacks and statistical attacks and that these attacks cannot be effectively mitigated without sacrificing the usability of LRP systems. Quantitative analysis proves that a secure LRP system in practical settings imposes a considerable amount of cognitive workload unless certain secure channels are involved. The book introduces a secur

  18. Elevated serum levels of vascular endothelial growth factor predict a poor prognosis of platinum-based chemotherapy in non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Zang JL

    2017-01-01

    Full Text Available Jialan Zang,1–3,* Yong Hu,1,2,* Xiaoyue Xu,1,2 Jie Ni,1,2 Dali Yan,1,2 Siwen Liu,4 Jieyu He,5 Jing Xue,4 Jianzhong Wu,4 Jifeng Feng2 1The Fourth Clinical School of Nanjing Medical University, 2Department of Chemotherapy, Nanjing Medical University Affiliated Cancer Hospital, Nanjing, 3Department of Oncology, The First Hospital of Harbin City, Harbin, 4Center of Clinical Laboratory, Nanjing Medical University Affiliated Cancer Hospital, 5Department of Public Health, Southeast University, Nanjing, People’s Republic of China *These authors contributed equally to this work Aim: This study was designed to investigate the predictive and prognostic values of serum vascular endothelial growth factor (VEGF level in non-small cell lung cancer (NSCLC patients treated with platinum-based chemotherapy. Methods: Patients’ peripheral blood samples were collected prior to chemotherapy and after 1 week of the third cycle of combination chemotherapy. Serum VEGF levels were evaluated through Luminex multiplex technique. Between September 2011 and August 2015, a total of 135 consecutive advanced or recurrent histologically verified NSCLC patients were enrolled in the study. Moreover, all the patients received platinum-based combination chemotherapy as a first-line treatment. Results: No significant associations were found between pretreatment serum VEGF levels and clinical characteristics, such as sex (P=0.0975, age (P=0.2522, stage (P=0.1407, lymph node metastasis (P=0.6409, tumor location (P=0.3520, differentiated degree (P=0.5608, pathological (histological type (P=0.4885, and response to treatment (P=0.9859. The VEGF load per platelet (VEGFPLT levels were not correlated with sex, age, primary tumor site, and pathological type in NSCLC patients (all P>0.05. The median survival time of progression-free survival (PFS was 6.407 and 5.29 months in the low and high groups, respectively, when using 280 pg/mL VEGF level as the cutoff point (P=0.024. Conclusion

  19. Ethamsylate and lung permeability in ventilated immature newborn rabbits.

    Science.gov (United States)

    Amato, M; Sun, B; Robertson, B

    1994-01-01

    The leakage of proteins in the immature neonatal lung can reduce the effect of exogenous surfactant. The effect of ethamsylate, a more specific prostaglandin inhibitor than indomethacin and aspirin-like drugs, on alveolar albumin leak was studied in a group of 27 immature newborn rabbits (gestational age 27 days). A pilot study was carried out using 4 animals and low-dose ethamsylate (10 mg/kg). A second group of animals (n = 12) received at birth, by intravenous injection, ethamsylate (50 mg/kg) and 10% human albumin (7 ml/kg). Animals not receiving ethamsylate (n = 11) served as control group. After 30 min of artificial ventilation with standard tidal volume (10 ml/kg) the lungs were lavaged and the amount of human albumin in lung lavage fluid was determined by immunodiffusion. No statistically significant differences were found in lung-thorax compliance and vascular to alveolar albumin leak between ethamsylate-treated animals and controls (p > 0.5). However, there was a statistically significant negative correlation between protein leak and lung compliance (r = -0.41; p ethamsylate administration on neonatal lung permeability in the immature neonate confirming that lung permeability is inversely related to compliance.

  20. Pulmonary artery reconstruction with a tailor-made bovine pericardial conduit following sleeve resection of a long segmental pulmonary artery for the treatment of lung cancer: technical details of the dog-ear method for adjusting diameter during vascular anastomosis.

    Science.gov (United States)

    Shimizu, Kimihiro; Nagashima, Toshiteru; Ohtaki, Yoichi; Takahashi, Toru; Mogi, Akira; Kuwano, Hiroyuki

    2017-05-01

    Sleeve resection of the pulmonary artery (PA) is always required for lung-sparing operations in which half or more of the vessel circumference is infiltrated by the primary tumor or metastatic hilar nodes. Following sleeve resection, conduit reconstruction may be indicated if there is excessive distance between the two vascular stumps, because there is a high degree of tension when repaired by direct anastomosis. We herein present a case of PA reconstruction using a tailor-made bovine pericardial conduit after sleeve resection of PA during lung cancer surgery. The length of resection was longer than 3 cm, and the difference in diameter between the conduit and peripheral PA stump was larger than 0.5 cm. We describe the surgical and oncological merits of a bovine pericardial conduit, and provide details of our reconstruction technique, focusing on adjustment of diameter between the conduit and peripheral PA (dog-ear method).

  1. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  2. Decreased plasma levels of the endothelial protective sphingosine-1-phosphate are associated with dengue-induced plasma leakage

    NARCIS (Netherlands)

    Michels, M.; Japtok, L.; Alisjahbana, B.; Wisaksana, R.; Sumardi, U.; Puspita, M.; Kleuser, B.; Mast, Q. de; Ven, A.J.A.M. van der

    2015-01-01

    BACKGROUND: A transient endothelial hyperpermeability is a hallmark of severe dengue infections. Sphingosine-1-phosphate (S1P) maintains vascular integrity and protects against plasma leakage. We related plasma S1P levels to dengue-induced plasma leakage and studied mechanisms that may underlie the

  3. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  4. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  5. Human amnion as a biological dressing used to prevent prolonged air leakage in thoracic surgery

    International Nuclear Information System (INIS)

    Mijewski, M.; Uhrynowska-Tyszkiewicz, I.; Piech, K.; Gogowski, M.

    2008-01-01

    Full text: Prolonged air leakage lasting 7 days or more is one of the most common complications in thoracic surgery. This complication may result in increased morbidity and prolonged hospital stay. Amnion allografts have been used to minimise this complication. The aim of our study was to evaluate the usefulness of human amnion grafts in the treatment of air leakage following thoracic surgery. Deep-frozen, radiation-sterilized (35 kGy) human amnion grafts prepared at the Central Tissue Bank in Warsaw (Poland) were used. Amnion allografts were applied to 69 patients who had surgery: 36 thoracotomies, and 33 rethoracotomies had been performed. During lung ventilation the air leakage sites were identified and covered by the amnion flap. Air leakage were evaluated during the postoperative period. Retrospectively we analysed air leakage duration in 170 thoracothomies and rethoracotomies without amnion transplantation. The separation of lung tissue and the liberation of pleural adhesions may be result in the lung and visceral pleura injury. Deep-frozen and radiation-sterilized human amnion is biocompatible, flexible, strong and airtight. It may be easily attached to the lung parenchyma and allows coverage of the area of the lung parenchyma deprived of the visceral pleura. The use of human amnion allografts is simple and safe. After treatment with amnion in 85% of the cases air leakage last less than 7 days, and only its traces were observed. Our results suggest that the human amnion grafts applied for the prevention of air leakage in lung surgery is a safe, simple and effective method. (Author)

  6. Vascular plugs - A key companion to Interventionists - 'Just Plug it'.

    Science.gov (United States)

    Ramakrishnan, Sivasubramanian

    2015-01-01

    Vascular plugs are ideally suited to close extra-cardiac, high flowing vascular communications. The family of vascular plugs has expanded. Vascular plugs in general have a lower profile and the newer variants can be delivered even through a diagnostic catheter. These features make them versatile and easy to use. The Amplatzer vascular plugs are also used for closing intracardiac defects including coronary arterio-venous fistula and paravalvular leakage in an off-label fashion. In this review, the features of currently available vascular plugs are reviewed along with tips and tricks of using them in the cardiac catheterization laboratory. Copyright © 2015. Published by Elsevier B.V.

  7. Atorvastatin along with imipenem attenuates acute lung injury in sepsis through decrease in inflammatory mediators and bacterial load.

    Science.gov (United States)

    Choudhury, Soumen; Kandasamy, Kannan; Maruti, Bhojane Somnath; Addison, M Pule; Kasa, Jaya Kiran; Darzi, Sazad A; Singh, Thakur Uttam; Parida, Subhashree; Dash, Jeevan Ranjan; Singh, Vishakha; Mishra, Santosh Kumar

    2015-10-15

    Lung is one of the vital organs which is affected during the sequential development of multi-organ dysfunction in sepsis. The purpose of the present study was to examine whether combined treatment with atorvastatin and imipenem could attenuate sepsis-induced lung injury in mice. Sepsis was induced by caecal ligation and puncture. Lung injury was assessed by the presence of lung edema, increased vascular permeability, increased inflammatory cell infiltration and cytokine levels in broncho-alveolar lavage fluid (BALF). Treatment with atorvastatin along with imipenem reduced the lung bacterial load and pro-inflammatory cytokines (IL-1β and TNFα) level in BALF. The markers of pulmonary edema such as microvascular leakage and wet-dry weight ratio were also attenuated. This was further confirmed by the reduced activity of MPO and ICAM-1 mRNA expression, indicating the lesser infiltration and adhesion of inflammatory cells to the lungs. Again, expression of mRNA and protein level of iNOS in lungs was also reduced in the combined treatment group. Based on the above findings it can be concluded that, combined treatment with atorvastatin and imipenem dampened the inflammatory response and reduced the bacterial load, thus seems to have promising therapeutic potential in sepsis-induced lung injury in mice. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Containment leakage rate testing requirements

    International Nuclear Information System (INIS)

    Arndt, E.G.

    1992-01-01

    This report presents the status of several documents under revision or development that provide requirements and guidance for testing nuclear power plant containment systems for leakage rates. These documents include the general revision to 10 CFR Part 50, Appendix J; the regulatory guide affiliated with the revision to Appendix J; the national standard that the regulatory guide endorses, ANSI/ANS-56.8, 'Containment System Leakage Rate Testing Requirements'; and the draft industry Licensing Topical Report, 'Standardized Program for Primary Containment Integrity Testing'. The actual or potential relationships between these documents are also explored

  9. Practical Leakage-Resilient Symmetric Cryptography

    DEFF Research Database (Denmark)

    Faust, Sebastian; Pietrzak, Krzysztof; Schipper, Joachim

    2012-01-01

    Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount of arbitr......Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount...

  10. Inhibition of Pyk2 blocks lung inflammation and injury in a mouse model of acute lung injury

    Directory of Open Access Journals (Sweden)

    Duan Yingli

    2012-01-01

    Full Text Available Abstract Background Proline-rich tyrosine kinase 2 (Pyk2 is essential in neutrophil degranulation and chemotaxis in vitro. However, its effect on the process of lung inflammation and edema formation during LPS induced acute lung injury (ALI remains unknown. The goal of the present study was to determine the effect of inhibiting Pyk2 on LPS-induced acute lung inflammation and injury in vivo. Methods C57BL6 mice were given either 10 mg/kg LPS or saline intratracheally. Inhibition of Pyk2 was effected by intraperitoneal administration TAT-Pyk2-CT 1 h before challenge. Bronchoalveolar lavage analysis of cell counts, lung histology and protein concentration in BAL were analyzed at 18 h after LPS treatment. KC and MIP-2 concentrations in BAL were measured by a mouse cytokine multiplex kit. The static lung compliance was determined by pressure-volume curve using a computer-controlled small animal ventilator. The extravasated Evans blue concentration in lung homogenate was determined spectrophotometrically. Results Intratracheal instillation of LPS induced significant neutrophil infiltration into the lung interstitium and alveolar space, which was attenuated by pre-treatment with TAT-Pyk2-CT. TAT-Pyk2-CT pretreatment also attenuated 1 myeloperoxidase content in lung tissues, 2 vascular leakage as measured by Evans blue dye extravasation in the lungs and the increase in protein concentration in bronchoalveolar lavage, and 3 the decrease in lung compliance. In each paradigm, treatment with control protein TAT-GFP had no blocking effect. By contrast, production of neutrophil chemokines MIP-2 and keratinocyte-derived chemokine in the bronchoalveolar lavage was not reduced by TAT-Pyk2-CT. Western blot analysis confirmed that tyrosine phosphorylation of Pyk2 in LPS-challenged lungs was reduced to control levels by TAT-Pyk2-CT pretreatment. Conclusions These results suggest that Pyk2 plays an important role in the development of acute lung injury in mice and

  11. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  12. Issues behind Competitiveness and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the vulnerability of heavy industry to carbon leakage and competitiveness loss. It reviews the existing literature on competitiveness and carbon leakage under uneven climate policies. It also suggests a statistical method to track carbon leakage, and applies this methodology to Phase I of the EU emissions trading scheme, for various industrial activities: iron and steel, cement, aluminium and refineries. Finally, it reviews measures to mitigate carbon leakage, as discussed in Australia, Canada, Europe, New Zealand and the US.

  13. Subsea Hydraulic Leakage Detection and Diagnosis

    OpenAIRE

    Stavenes, Thomas

    2010-01-01

    The motivation for this thesis is reduction of hydraulic emissions, minimizing of process emergency shutdowns, exploitation of intervention capacity, and reduction of costs. Today, monitoring of hydraulic leakages is scarce and the main way to detect leakage is the constant need for filling of hydraulic fluid to the Hydraulic Power Unit (HPU). Leakage detection and diagnosis has potential, which would be adressed in this thesis. A strategy towards leakage detection and diagnosis is given....

  14. Simulation of leakage through mechanical sealing device

    Science.gov (United States)

    Tikhomorov, V. P.; Gorlenko, O. A.; Izmerov, M. A.

    2018-03-01

    The procedure of mathematical modeling of leakage through the mechanical seal taking into account waviness and roughness is considered. The percolation process is represented as the sum of leakages through a gap between wavy surfaces and percolation through gaps formed by fractal roughness, i.e. the total leakage is determined by the slot model and filtration leakage. Dependences of leaks on the contact pressure of corrugated and rough surfaces of the mechanical seal elements are presented.

  15. Efficacy and safety of TachoSil® versus standard treatment of air leakage after pulmonary lobectomy

    DEFF Research Database (Denmark)

    Marta, Gabriel Mihai; Facciolo, Francesco; Ladegaard, Lars

    2010-01-01

    Alveolar air leakage remains a serious problem in lung surgery, being associated with increased postoperative morbidity, prolonged hospital stay and greater health-care costs. The aim of this study was to evaluate the sealing efficacy and safety of the surgical patch, TachoSil®, in lung surgery....

  16. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  17. CT evaluation of local leakage of bone cement after percutaneous kyphoplasty and vertebroplasty

    International Nuclear Information System (INIS)

    Lee, In Jae; Choi, A. Lam; Yie, Mi-Yeon; Yoon, Ji Young; Jeon, Eui Yong; Koh, Sung Hye; Yoon, Dae Young; Lim, Kyung Ja; Im, Hyoung June

    2010-01-01

    Background: Percutaneous injection of bone cement (acrylic cement) during percutaneous kyphoplasty and vertebroplasty can cause symptomatic or asymptomatic complications due to leakage, extravasation or vascular migration of cement. Purpose: To investigate and to compare the incidence and site of local leakage or complications of bone cement after percutaneous kyphoplasty and vertebroplasty using bone cement. Material and Methods: We retrospectively reviewed 473 cases of percutaneous kyphoplasty or vertebroplasty performed under fluoroscopic guidance. Of the 473 cases, follow-up CT scans that covered the treated bones were available for 83 cases (59 kyphoplasty and 24 vertebroplasty). Results: The rate of local leakage of bone cement was 87.5% (21/24) for percutaneous vertebroplasty and 49.2% (29/59) for kyphoplasty. The most common site of local leakage was perivertebral soft tissue (n=8, 38.1%) for vertebroplasty. The most common site of local leakage was a perivertebral vein (n=7, 24.1%) for kyphoplasty. Two cases of pulmonary cement embolism developed: one case after kyphoplasty and one case after vertebroplasty. Conclusion: Local leakage of bone cement was more common for percutaneous vertebroplasty compared with kyphoplasty (P<0.005). The most common sites of local leakage were perivertebral soft tissue and perivertebral vein.

  18. Functional high-resolution computed tomography of pulmonary vascular and airway reactions. Experimental results. Funktionelle HR-CT der Lunge. Experimentelle Untersuchungen pulmonaler Gefaess- und Atemwegsreaktionen

    Energy Technology Data Exchange (ETDEWEB)

    Herold, C.J. (Universitaetsklinik fuer Radiodiagnostik, Vienna (Austria) Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology); Brown, R.H. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Anesthesiology and Intensive Care Medicine Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Physiology); Wetzel, R.C.; Herold, S.M. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Anesthesiology and Intensive Care Medicine); Zeerhouni, E.A. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology)

    1993-03-01

    We describe the use of high-resolution computed tomography (HRCT) for assessment of the function of pulmonary vessels and airways. With its excellent spatial resolution, HRCT is able to demonstrate pulmonary structures as small as 300 [mu]m and can be used to monitor changes following various stimuli. HRCT also provides information about structures smaller than 300 [mu]m through measurement of parenchymal background density. To date, sequential, spiral and ultrafast HRCT techniques have been used in a variety of challenges to gather information about the anatomical correlates of traditional physiological measurements, thus making anatomical-physiological correlation possible. HRCT of bronchial reactivity can demonstrate the location and time course of aerosol-induced broncho-constriction and may show changes not apparent on spirometry. HRCT of the pulmonary vascular system visualized adaptations of vessels during hypoxia and intravascular volume loading and elucidates cardiorespiratory interactions. Experimental studies provide a basis for potential clinical applications of this method. (orig.).

  19. Contrast media for radiological examination in gastrointestinal tract leakage

    International Nuclear Information System (INIS)

    Ginai-Karamat, A.Z.

    1987-01-01

    The aim of this investigation has been to find a safe and suitable contrast medium (CM) for radiological evaluation of the gastrointestinal tract (GIT) in cases where leakage outside the GIT can be suspected. An experimental study was carried out to evaluate the reactions of various available CM in the bronchi and lungs, mediastinum, pleura and peritoneum of rats. The CM evaluated in the experimental study were, pure barium sulphate (without any additives), commercial barium sulphate (Micropaque, with additives), Dionosil, Hytrast, Gastrografin, Amipaque (in pleura Omnipaque) and Hexabrix. (Auth.)

  20. Reverse airflow in certain chest drains may be misinterpreted as prolonged air leakage

    DEFF Research Database (Denmark)

    Stouby, Anna; Neckelmann, Kirsten; Licht, Peter B

    2011-01-01

    Prolonged air leakage is common after lung resection. We observed that during deep inspiration some patients were able to empty the water-seal of commercial chest drainage systems and retract air back into the chest tube, which subsequently escaped during the following expiration, mimicking "true...

  1. Vascular Hyperpermeability Response in Animals Systemically Exposed to Arsenic.

    Science.gov (United States)

    Chen, Shih-Chieh; Chang, Chao-Yuah; Lin, Ming-Lu

    2018-01-01

    The mechanisms underlying cardiovascular diseases induced by chronic exposure to arsenic remain unclarified. The objectives of this study were to investigate whether increased vascular leakage is induced by inflammatory mustard oil in mice systemically exposed to various doses of arsenic and whether an increased vascular leakage response is still present in arsenic-fed mice after arsenic discontinuation for 2 or 6 months. ICR mice were fed water or various doses of sodium arsenite (10, 15, or 20 mg/kg/day; 5 days/week) for 8 weeks. In separate experiments, the mice were treated with sodium arsenite (20 mg/kg) for 2 or 8 weeks, followed by arsenic discontinuation for 2 or 6 months. Vascular permeability to inflammatory mustard oil was quantified using Evans blue (EB) techniques. Both arsenic-exposed and water-fed (control) mice displayed similar basal levels of EB leakage in the ears brushed with mineral oil, a vehicle of mustard oil. The levels of EB leakage induced by mustard oil in the arsenic groups fed with sodium arsenite (10 or 15 mg/kg) were similar to those of water-fed mice. However, increased levels of EB leakage in response to mustard oil stimulation were significantly higher in mice treated with sodium arsenite (20 mg/kg; high dose) than in arsenic-fed (10 or 15 mg/kg; low and middle doses) or control mice. After arsenic discontinuation for 2 or 6 months, mustard oil-induced vascular EB leakage in arsenic-fed (20 mg/kg) mice was similar to that in control mice. Dramatic increases in mustard oil-induced vascular leakage were only present in mice systemically exposed to the high arsenic dose, indicating the synergistic effects of the high arsenic dose and mustard oil.

  2. Vascular Endothelial Growth Factor in Plasma and Pleural Effusion Is a Biomarker for Outcome After Bevacizumab plus Carboplatin-Paclitaxel Treatment for Non-small Cell Lung Cancer with Malignant Pleural Effusion.

    Science.gov (United States)

    Tamiya, Motohiro; Tamiya, Akihiro; Yasue, Tomomi; Nakao, Keiko; Omachi, Naoki; Shiroyama, Takayuki; Tani, Eriko; Hamaguchi, Masanari; Morishita, Naoko; Suzuki, Hidekazu; Okamoto, Norio; Okishio, Kyoichi; Kawaguchi, Tomoya; Atagi, Shinji; Hirashima, Tomonori

    2016-06-01

    Malignant effusion is associated with high serum and plasma levels of vascular endothelial growth factor (VEGF). There are no biomarkers of outcome for bevacizumab treatment in patients with malignant pleural effusion (MPE). We previously reported that carboplatin-paclitaxel plus bevacizumab was effective for patients with advanced non-squamous non-small cell lung cancer (NSCLC) and MPE, although we did not evaluate the relationship between treatment outcomes and plasma or pleural effusion levels of VEGF. Therefore, this study evaluated whether plasma or pleural effusion VEGF might predict bevacizumab treatment outcome. We enrolled 23 patients with NSCLC and MPE between September 2010 and June 2012. Plasma VEGF levels were measured in 19 patients and pleural VEGF levels were measured in 22 patients. Compared to patients with a low plasma VEGF level, patients with a high level exhibited significantly shorter overall survival (OS: 13.8 vs. 6.5 months, p=0.04), progression-free survival (PFS: 8.7 vs. 4.8 months, peffusion, patients with a high VEGF level exhibited significantly shorter OS (19.6 vs. 6.9 months, peffusion may predict the outcome of bevacizumab treatment in patients with NSCLC and MPE. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  3. Vascular permeability and iron deposition biomarkers in longitudinal follow-up of cerebral cavernous malformations

    DEFF Research Database (Denmark)

    Girard, Romuald; Fam, Maged D; Zeineddine, Hussein A

    2017-01-01

    OBJECTIVE Vascular permeability and iron leakage are central features of cerebral cavernous malformation (CCM) pathogenesis. The authors aimed to correlate prospective clinical behavior of CCM lesions with longitudinal changes in biomarkers of dynamic contrast-enhanced quantitative permeability (...

  4. Why the CDM can reduce carbon leakage

    International Nuclear Information System (INIS)

    Kallbekken, S.

    2006-04-01

    Carbon leakage is an important concern because it can reduce the environmental effectiveness of the Kyoto Protocol. The Clean Development Mechanism, one of the flexibility mechanisms allowed under the protocol, has the potential to reduce carbon leakage significantly because it reduces the relative competitive disadvantage to Annex B countries of restricting greenhouse gas emissions. The economic intuition behind this mechanism is explored in a theoretical analysis. It is then analyzed numerically using a CGE model. The results indicate that, assuming appropriate accounting for leakage and under realistic assumptions on CDM activity, the CDM has the potential to reduce the magnitude of carbon leakage by around three fifths

  5. Postprocedural CT for perivertebral cement leakage in percutaneous vertebroplasty is not necessary - results from VERTOS II

    International Nuclear Information System (INIS)

    Venmans, Alexander; Klazen, Caroline A.; Rooij, Willem Jan van; Lohle, Paul N.; Vries, Jolanda de; Mali, Willem P.

    2011-01-01

    During percutaneous vertebroplasty (PV), perivertebral cement leakage frequently occurs. There is some concern that cement deposits may migrate towards the lungs via the veins during follow-up. We used baseline and follow-up computed tomography (CT) to assess the incidence and extend of late cement migration in a large consecutive patient cohort. VERTOS II is a prospective multicenter randomized controlled trial comparing PV with conservative therapy for osteoporotic vertebral compression fractures (OVCFs). Patients assigned to PV had baseline postprocedural CT scans of the treated vertebral bodies. After a mean follow-up of 22 months, 54 of 78 patients (69%) had follow-up CT. CT scans were analyzed and compared for perivertebral venous, discal, and soft tissue leakage. Perivertebral cement leakage occurred in 64 of 80 treated vertebrae (80%; 95% CI, 70% to 87%). All patients remained asymptomatic. Perivertebral venous leakage was present in 56 vertebrae (88%), mostly in the anterior external venous plexus (46 of 56, 82%). Discal leakage occurred in 22 of 64 vertebrae (34%) and soft tissue leakage in two of 64 (4%). Mean injected cement volume in vertebrae with leakage was higher (4.5 versus 3.7 cm 3 , p = 0.04). Follow-up CT scan showed unchanged perivertebral cement leakages without late cement migration. Perivertebral cement leaks during PV for OVCFs occurred frequently in the VERTOS II trial. Cement leakage occurred more frequently with higher injected volumes. However, all patients remained asymptomatic, and late cement migration during follow-up did not occur. Standard postprocedural CT of the treated vertebral body in PV is not necessary. (orig.)

  6. Postprocedural CT for perivertebral cement leakage in percutaneous vertebroplasty is not necessary - results from VERTOS II

    Energy Technology Data Exchange (ETDEWEB)

    Venmans, Alexander; Klazen, Caroline A.; Rooij, Willem Jan van; Lohle, Paul N. [St. Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Vries, Jolanda de [St. Elisabeth Ziekenhuis Tilburg, Department of Medical Psychology, Tilburg (Netherlands); Mali, Willem P. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands)

    2011-01-15

    During percutaneous vertebroplasty (PV), perivertebral cement leakage frequently occurs. There is some concern that cement deposits may migrate towards the lungs via the veins during follow-up. We used baseline and follow-up computed tomography (CT) to assess the incidence and extend of late cement migration in a large consecutive patient cohort. VERTOS II is a prospective multicenter randomized controlled trial comparing PV with conservative therapy for osteoporotic vertebral compression fractures (OVCFs). Patients assigned to PV had baseline postprocedural CT scans of the treated vertebral bodies. After a mean follow-up of 22 months, 54 of 78 patients (69%) had follow-up CT. CT scans were analyzed and compared for perivertebral venous, discal, and soft tissue leakage. Perivertebral cement leakage occurred in 64 of 80 treated vertebrae (80%; 95% CI, 70% to 87%). All patients remained asymptomatic. Perivertebral venous leakage was present in 56 vertebrae (88%), mostly in the anterior external venous plexus (46 of 56, 82%). Discal leakage occurred in 22 of 64 vertebrae (34%) and soft tissue leakage in two of 64 (4%). Mean injected cement volume in vertebrae with leakage was higher (4.5 versus 3.7 cm{sup 3}, p = 0.04). Follow-up CT scan showed unchanged perivertebral cement leakages without late cement migration. Perivertebral cement leaks during PV for OVCFs occurred frequently in the VERTOS II trial. Cement leakage occurred more frequently with higher injected volumes. However, all patients remained asymptomatic, and late cement migration during follow-up did not occur. Standard postprocedural CT of the treated vertebral body in PV is not necessary. (orig.)

  7. Valve packing leakage monitoring device

    International Nuclear Information System (INIS)

    Ezekoye, L.I.

    1985-01-01

    A device for monitoring leakage of fluid across a seal in a component connected to a pressurized fluid system including a housing having a chamber with an inlet for receiving fluid leaking across the seal and an outlet. A positioning means is connected to an orifice plug so as to move the plug for permitting the fluid to be discharged through the orifice at the same rate at which it enters the first chamber and means for detecting the movement of the plug is provided to produce and output signal corresponding to the distance moved by the plug and thereby indicate flow rate. The positioning means compromise a piston attached to the plug by a hollow tube and springs, which at low flow rates locate the piston. When flow increases sufficiently pressure increases and urges the piston upwards. A magnetic portion of tube actuates a succession of proximity switches to indicate flow rate. (author)

  8. VASCULAR SURGERY

    African Journals Online (AJOL)

    2016-06-02

    Jun 2, 2016 ... with the literature from South Africa over the last four decades, and reflects the high rate of interpersonal violence in the country.14,15 As expected, cervical ... via the intact circle of Willis in young patients is the most likely explanation for the lack of strokes. Five patients were referred to the Durban vascular ...

  9. Vascular Disorders

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Vascular Disorders Email to a friend * required fields ...

  10. Sensing of Vascular Permeability in Inflamed Vessel of Live Animal

    Directory of Open Access Journals (Sweden)

    Sang A Park

    2018-01-01

    Full Text Available Increase in vascular permeability is a conclusive response in the progress of inflammation. Under controlled conditions, leukocytes are known to migrate across the vascular barriers to the sites of inflammation without severe vascular rupture. However, when inflammatory state becomes excessive, the leakage of blood components may occur and can be lethal. Basically, vascular permeability can be analyzed based on the intensity of blood outflow. To evaluate the amount and rate of leakage in live mice, we performed cremaster muscle exteriorization to visualize blood flow and neutrophil migration. Using two-photon intravital microscopy of the exteriorized cremaster muscle venules, we found that vascular barrier function is transiently and locally disrupted in the early stage of inflammatory condition induced by N-formylmethionyl-leucyl-phenylalanine (fMLP. Measurement of the concentration of intravenously (i.v. injected Texas Red dextran inside and outside the vessels resulted in clear visualization of real-time increases in transient and local vascular permeability increase in real-time manner. We successfully demonstrated repeated leakage from a target site on a blood vessel in association with increasing severity of inflammation. Therefore, compared to other methods, two-photon intravital microscopy more accurately visualizes and quantifies vascular permeability even in a small part of blood vessels in live animals in real time.

  11. Mechanisms of enhanced lung injury during sepsis

    DEFF Research Database (Denmark)

    Czermak, B J; Breckwoldt, M; Ravage, Z B

    1999-01-01

    . Enhanced lung injury was associated with increased accumulation of neutrophils in lung, enhanced production of CXC chemokines (but not tumor necrosis factor-alpha) in bronchoalveolar lavage fluids, and increased expression of lung vascular intercellular adhesion molecule-1 (ICAM-1). Complement depletion...

  12. Forest Carbon Leakage Quantification Methods and Their Suitability for Assessing Leakage in REDD

    Directory of Open Access Journals (Sweden)

    Sabine Henders

    2012-01-01

    Full Text Available This paper assesses quantification methods for carbon leakage from forestry activities for their suitability in leakage accounting in a future Reducing Emissions from Deforestation and Forest Degradation (REDD mechanism. To that end, we first conducted a literature review to identify specific pre-requisites for leakage assessment in REDD. We then analyzed a total of 34 quantification methods for leakage emissions from the Clean Development Mechanism (CDM, the Verified Carbon Standard (VCS, the Climate Action Reserve (CAR, the CarbonFix Standard (CFS, and from scientific literature sources. We screened these methods for the leakage aspects they address in terms of leakage type, tools used for quantification and the geographical scale covered. Results show that leakage methods can be grouped into nine main methodological approaches, six of which could fulfill the recommended REDD leakage requirements if approaches for primary and secondary leakage are combined. The majority of methods assessed, address either primary or secondary leakage; the former mostly on a local or regional and the latter on national scale. The VCS is found to be the only carbon accounting standard at present to fulfill all leakage quantification requisites in REDD. However, a lack of accounting methods was identified for international leakage, which was addressed by only two methods, both from scientific literature.

  13. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  14. Leakage-resilient cryptography from minimal assumptions

    DEFF Research Database (Denmark)

    Hazay, Carmit; López-Alt, Adriana; Wee, Hoeteck

    2013-01-01

    We present new constructions of leakage-resilient cryptosystems, which remain provably secure even if the attacker learns some arbitrary partial information about their internal secret key. For any polynomial ℓ, we can instantiate these schemes so as to tolerate up to ℓ bits of leakage. While the...

  15. Predicting Envelope Leakage in Attached Dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, O. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Arena, L. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Griffiths, D. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  16. Leakage of caesium braquitherapy sources

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    In several Venezuelan public hospitals where cervix uteri tumours are treated by intracavitary radiotherapy, that use manual after loading Fletcher method, with Caesium 137 sources, the use of improper source holders, locally manufactured from pieces of drainage plastic tubing, which deteriorated and created a corrosive environment all around the sources, omission of manufacturer's recommendations regarding corrosion information, source storage, inspection and testing, violation of International Atomic Energy Agency Radiation Protection Procedures, and lack of proper regulatory control, resulted integrity damage to about sixty special form sources (ISO2919 C 63322), leakage of Cs-137 from a supposed insoluble refractory active content (caesium silicoaluminate), and contamination of applicators, floors and bedding. When the situation was detected by means removal contamination tests, after routine inspections, the sources were removed from the hospitals, decontaminated by means of immersion in 3% EDTA solution in ultrasonic bath, subjected to leaking assessment tests, and the ones that passed were placed in low cost stainless steel source holders, designed and built by the instituto Venezolano de Investigaciones Cientificas (IVIC) returned to the hospitals. The leaking sources were removed from use and considered radioactive waste. In order to avoid the occurrence of similar situations, all the importers of such sources are now required to send them to IVIC for testing and placement in proper source holders, before they are shipped to the hospitals. (author)

  17. Climate Policy and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the effects of the EU emissions trading scheme on the aluminium sector (i.e. competitiveness loss and carbon leakage). With its very high electricity intensity, primary aluminium stands out in the heavy industry picture: a sector whose emissions are not capped in the present EU ETS, European aluminium smelters still stand to lose profit margins and, possibly, market shares, as electricity prices increase following CO2 caps on generators' emissions - the famous pass-through of CO2 prices into electricity prices. The analysis includes a method of quantification of this issue, based on two indicators: profit margins and trade flows. As the EU is at the forefront of such policy, the paper provides policy messages to all countries on how trade exposed energy-intensive industries can be 'moved' by carbon constraint. This also is a contentious topic in Australia, Japan, New Zealand, and the US, where ambitious climate policies -- including cap-and-trade systems -- are currently debated.

  18. Experimental evaluation of clinical colon anastomotic leakage.

    Science.gov (United States)

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the

  19. Sildenafil attenuates pulmonary inflammation and fibrin deposition, mortality and right ventricular hypertrophy in neonatal hyperoxic lung injury

    Directory of Open Access Journals (Sweden)

    Boersma Hester

    2009-04-01

    Full Text Available Abstract Background Phosphodiesterase-5 inhibition with sildenafil has been used to treat severe pulmonary hypertension and bronchopulmonary dysplasia (BPD, a chronic lung disease in very preterm infants who were mechanically ventilated for respiratory distress syndrome. Methods Sildenafil treatment was investigated in 2 models of experimental BPD: a lethal neonatal model, in which rat pups were continuously exposed to hyperoxia and treated daily with sildenafil (50–150 mg/kg body weight/day; injected subcutaneously and a neonatal lung injury-recovery model in which rat pups were exposed to hyperoxia for 9 days, followed by 9 days of recovery in room air and started sildenafil treatment on day 6 of hyperoxia exposure. Parameters investigated include survival, histopathology, fibrin deposition, alveolar vascular leakage, right ventricular hypertrophy, and differential mRNA expression in lung and heart tissue. Results Prophylactic treatment with an optimal dose of sildenafil (2 × 50 mg/kg/day significantly increased lung cGMP levels, prolonged median survival, reduced fibrin deposition, total protein content in bronchoalveolar lavage fluid, inflammation and septum thickness. Treatment with sildenafil partially corrected the differential mRNA expression of amphiregulin, plasminogen activator inhibitor-1, fibroblast growth factor receptor-4 and vascular endothelial growth factor receptor-2 in the lung and of brain and c-type natriuretic peptides and the natriuretic peptide receptors NPR-A, -B, and -C in the right ventricle. In the lethal and injury-recovery model we demonstrated improved alveolarization and angiogenesis by attenuating mean linear intercept and arteriolar wall thickness and increasing pulmonary blood vessel density, and right ventricular hypertrophy (RVH. Conclusion Sildenafil treatment, started simultaneously with exposure to hyperoxia after birth, prolongs survival, increases pulmonary cGMP levels, reduces the pulmonary

  20. Small GTP-Binding Protein Rac Is an Essential Mediator of Vascular Endothelial Growth Factor-Induced Endothelial Fenestrations and Vascular Permeability

    DEFF Research Database (Denmark)

    Eriksson, A.; Cao, R.; Tritsaris, K.

    2003-01-01

    fenestrated endothelium, a feature linked with increased vascular permeability. A cell-permeable Rac antagonist (TAT-RacN17) converted VEGF-induced, leaky vascular plexuses into well-defined vascular networks. In addition, this Rac mutant blocked formation of VEGF-induced endothelial fenestrations...... in mediation of VEGF-induced vascular permeability but less so in neovascularization. This may have conceptual implications for applying Rac antagonists in treatment and prevention of VEGF-induced vascular leakage and edema in connection with ischemic disorders....

  1. Leakage Resilient Secure Two-Party Computation

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Hazay, Carmit; Patra, Arpita

    2012-01-01

    we initiate the study of {\\em secure two-party computation in the presence of leakage}, where on top of corrupting one of the parties the adversary obtains leakage from the content of the secret memory of the honest party. Our study involves the following contributions: \\BE \\item {\\em Security...... and returns its result. Almost independently of secure computation, the area of {\\em leakage resilient cryptography} has recently been evolving intensively, studying the question of designing cryptographic primitives that remain secure even when some information about the secret key is leaked. In this paper...

  2. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  3. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  4. Signal attenuation due to cavity leakage

    International Nuclear Information System (INIS)

    Sherman, M.H.; Modera, M.P.

    1988-01-01

    The propagation of sound waves in fluids requires information about three properties of the system: capacitance (compressibility), resistance (friction), and inductance (inertia). Acoustical design techniques to date have tended to ignore the frictional effects associated with airflow across the envelope of the acoustic cavity (e.g., resistive vents). Since such leakage through the cavity envelope is best expressed with a power law dependence on the pressure, standard Fourier techniques that rely on linearity cannot be used. In this article, the theory relevant to nonlinear leakage is developed and equations presented. Potential applications of the theory to techniques for quantifying the leakage of buildings are presented. Experimental results from pressure decays in a full-scale test structure are presented and the leakage so measured is compared with independent measurements to demonstrate the technique

  5. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  6. Electroplating eliminates gas leakage in brazed areas

    Science.gov (United States)

    Leigh, J. D.

    1966-01-01

    Electroplating method seals brazed or welded joints against gas leakage under high pressure. Any conventional electroplating process with many different metal anodes can be used, as well as the build up of layers of different metals to any required thickness.

  7. Analysis of ONKALO water leakage mapping results

    International Nuclear Information System (INIS)

    Ahokas, H.; Nummela, J; Turku, J.

    2014-04-01

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  8. Analysis of ONKALO water leakage mapping results

    Energy Technology Data Exchange (ETDEWEB)

    Ahokas, H.; Nummela, J; Turku, J. [Poeyry Finland Oy, Vantaa (Finland)

    2014-04-15

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  9. Technology evaluation for space station atmospheric leakage

    Energy Technology Data Exchange (ETDEWEB)

    Lemon, D.K.; Friesel, M.A.; Griffin, J.W.; Skorpik, J.R.; Shepard, C.L.; Antoniak, Z.I.; Kurtz, R.J.

    1990-02-01

    A concern in operation of a space station is leakage of atmosphere through seal points and through the walls as a result of damage from particle (space debris and micrometeoroid) impacts. This report describes a concept for a monitoring system to detect atmosphere leakage and locate the leak point. The concept is based on analysis and testing of two basic methods selected from an initial technology survey of potential approaches. 18 refs., 58 figs., 5 tabs.

  10. History of Lung Transplantation.

    Science.gov (United States)

    Dabak, Gül; Şenbaklavacı, Ömer

    2016-04-01

    History of lung transplantation in the world can be traced back to the early years of the 20 th century when experimental vascular anastomotic techniques were developed by Carrel and Guthrie, followed by transplantation of thoracic organs on animal models by Demikhov and finally it was James Hardy who did the first lung transplantation attempt on human. But it was not until the discovery of cyclosporine and development of better surgical techniques that success could be achieved in that field by the Toronto Lung Transplant Group led by Joel Cooper. Up to the present day, over 51.000 lung transplants were performed in the world at different centers. The start of lung transplantation in Turkey has been delayed for various reasons. From 1998 on, there were several attempts but the first successful lung transplant was performed at Sureyyapasa Hospital in 2009. Today there are four lung transplant centers in Turkey; two in Istanbul, one in Ankara and another one in Izmir. Three lung transplant centers from Istanbul which belong to private sector have newly applied for licence from the Ministry of Health.

  11. Carbon leakage from a Nordic perspective

    Energy Technology Data Exchange (ETDEWEB)

    Naess-Schmidt, S.; Hansen, Martin Bo; Sand Kirk, J. [Copenhagen Economics, Copenhagen (Denmark)

    2012-02-15

    Carbon pricing is generally considered a highly effective tool in reducing carbon emissions. Putting a price on carbon provides incentives for users and producers of fossil fuels to reduce consumption and develop low carbon products and processes. However, pursuing an ambitious climate policy can lead to carbon leakage, which refers to a situation where unilateral or regional climate change policy drives the relocation of industry investments and installations, and associated emissions, to third countries. This report by Copenhagen Economics has been commissioned by the Nordic Council of Ministers to give an overview of the industries at risk of carbon leakage in the Nordic countries, and estimate the expected extent of carbon leakage from unilateral climate policies in the Nordic countries. The report also assesses available policy options that may reduce the risk of carbon leakage, such as exemptions from energy tax and exemptions from quota obligations under green certificate schemes. The key drivers of carbon leakage are identified, which include energy intensity, product differentiation, transportation costs and capital intensity. The analysis suggests that industries such as paper and pulp, iron and steel, aluminium, cement, pharmaceuticals, chemicals, and fertilizers are most at risk of carbon leakage in the Nordic manufacturing sector. (Author)

  12. Leakage test evaluation used for qualification of iodine-125 seeds sealing

    International Nuclear Information System (INIS)

    Feher, Anselmo; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Calvo, Wilson A.P.; Somessari, Samir L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R.

    2009-01-01

    The prostate cancer is a problem of public health in Brazil, and the second cause of cancer deaths in men, exceeded only by lung cancer. Among the possible treatments available for prostate cancer is brachytherapy, in which small seeds containing Iodine-125 radioisotope are implanted in the prostate. The seed consists of a sealed titanium tube measuring 0.8 mm external diameter and 4.5 mm in length, containing a central silver wire with adsorbed Iodine-125. The tube sealing is made with titanium at the ends, using electric arc welding or laser process. This sealing must be leakage-resistant and free of cracks, therefore avoiding the Iodine-125 to deposit in the silver wire to escape and spread into the human body. To ensure this problem does not occur, rigorous leakage tests, in accordance with the standard Radiation protection - Sealed Radioactive Sources - leakage Test Methods - ISO 9978, should be applied. The aim of this study is to determine, implement and evaluate the leakage test to be used in the Iodine-125 seeds production, in order to qualify the sealing procedure. The standard ISO 9978 presents a list of tests to be carried out according to the type of source. The preferential methods for brachytherapy sources are soaking and helium. To assess the seeds leakage, the method of immersion test at room temperature was applied. The seeds are considered leakage-free if the detected activity does not exceed the 185 Bq (5 nCi). An Iodine standard was prepared and its value determined in a sodium iodide detector. A liquid scintillation counter was calibrated with the standard for seeds leakage tests. Forty-eight seeds were welded for these tests. (author)

  13. Lung cancer

    International Nuclear Information System (INIS)

    Aisner, J.

    1985-01-01

    This book contains 13 chapters. Some of the chapter titles are: The Pathology of Lung Cancer; Radiotherapy for Non-Small-Cell Cancer of the Lung; Chemotherapy for Non-Small-Cell Lung Cancer; Immunotherapy in the Management of Lung Cancer; Preoperative Staging and Surgery for Non-Small-Cell Lung Cancer; and Prognostic Factors in Lung Cancer

  14. Pickering unit 1 containment leakage characterization

    International Nuclear Information System (INIS)

    Zakaib, G.D.

    1994-01-01

    Results of the design pressure test carried out on Pickering Reactor Building number 1 during late 1992 showed that the leakage rate of the building was close to the safety analysis value of 2.7% contained mass per hour at the design pressure of 41.4 kPa(g) and was significantly higher than that reported after the previous test conducted in the spring of 1987. This unexpected finding initiated the longest and the most comprehensive containment leakage investigation ever undertaken by Ontario Hydro. A thorough investigation of leakage behaviour by repeated testing, inspections, leak search and analysis was launched. The extensive leak search effort included items such as: leak source detection by soap solution application, use of ultrasonic detectors, fogging and tracer gas techniques, systematic systems isolation, thermal imaging of the exterior, and quantification of leak sites by flowmeter and bagging. Using a specially designed volumetric technique, the root cause of the problem was finally confirmed as being due to 'pressure dependent laminar leakage' through the hairline cracks in the dome concrete. Structural analysis indicated that the thermal gradients and pressure loading combined to cause the cracking early in the structure's operating history and that overall structural integrity has not been compromised. Leakage rate analysis using a new fluid mechanics model augmented by the effect of thermal strains indicated that the leakage could be significantly less under certain transient temperature gradient conditions. Several options for repairing the dome were considered by a multidisciplinary team and it was finally decided to apply a specially engineered multilayer elastomeric coating to the exterior concrete surface. When the unit was re-tested in October 1993, a dramatic ten-fold improvement in leakage rate (down to 0.25%/h at design pressure) was observed. This is lower than even the commissioning results and comparable to the performance of newer units

  15. How to attribute market leakage to CDM projects

    NARCIS (Netherlands)

    Vöhringer, F.; Kuosmanen, T.K.; Dellink, R.B.

    2006-01-01

    Economic studies suggest that market leakage rates of greenhouse gas abatement can reach the two-digit percentage range. Although the Marrakesh Accords require Clean Development Mechanism (CDM) projects to account for leakage, most projects neglect market leakage. Insufficient leakage accounting is

  16. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  17. Dexamethasone attenuates VEGF expression and inflammation but not barrier dysfunction in a murine model of ventilator-induced lung injury.

    Directory of Open Access Journals (Sweden)

    Maria A Hegeman

    Full Text Available BACKGROUND: Ventilator-induced lung injury (VILI is characterized by vascular leakage and inflammatory responses eventually leading to pulmonary dysfunction. Vascular endothelial growth factor (VEGF has been proposed to be involved in the pathogenesis of VILI. This study examines the inhibitory effect of dexamethasone on VEGF expression, inflammation and alveolar-capillary barrier dysfunction in an established murine model of VILI. METHODS: Healthy male C57Bl/6 mice were anesthetized, tracheotomized and mechanically ventilated for 5 hours with an inspiratory pressure of 10 cmH2O ("lower" tidal volumes of ∼7.5 ml/kg; LVT or 18 cmH2O ("higher" tidal volumes of ∼15 ml/kg; HVT. Dexamethasone was intravenously administered at the initiation of HVT-ventilation. Non-ventilated mice served as controls. Study endpoints included VEGF and inflammatory mediator expression in lung tissue, neutrophil and protein levels in bronchoalveolar lavage fluid, PaO2 to FiO2 ratios and lung wet to dry ratios. RESULTS: Particularly HVT-ventilation led to alveolar-capillary barrier dysfunction as reflected by reduced PaO2 to FiO2 ratios, elevated alveolar protein levels and increased lung wet to dry ratios. Moreover, VILI was associated with enhanced VEGF production, inflammatory mediator expression and neutrophil infiltration. Dexamethasone treatment inhibited VEGF and pro-inflammatory response in lungs of HVT-ventilated mice, without improving alveolar-capillary permeability, gas exchange and pulmonary edema formation. CONCLUSIONS: Dexamethasone treatment completely abolishes ventilator-induced VEGF expression and inflammation. However, dexamethasone does not protect against alveolar-capillary barrier dysfunction in an established murine model of VILI.

  18. Determination of leakage areas in nuclear piping

    International Nuclear Information System (INIS)

    Keim, E.

    1997-01-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack

  19. Sustainable management of leakage from wastewater pipelines.

    Science.gov (United States)

    DeSilva, D; Burn, S; Tjandraatmadja, G; Moglia, M; Davis, P; Wolf, L; Held, I; Vollertsen, J; Williams, W; Hafskjold, L

    2005-01-01

    Wastewater pipeline leakage is an emerging concern in Europe, especially with regards to the potential effect of leaking effluent on groundwater contamination and the effects infiltration has on the management of sewer reticulation systems. This paper describes efforts by Australia, in association with several European partners, towards the development of decision support tools to prioritize proactive rehabilitation of wastewater pipe networks to account for leakage. In the fundamental models for the decision support system, leakage is viewed as a function of pipeline system deterioration. The models rely on soil type identification across the service area to determine the aggressiveness of the pipe environment and for division of the area into zones based on pipe properties and operational conditions. By understanding the interaction between pipe materials, operating conditions, and the pipe environment in the mechanisms leading to pipe deterioration, the models allow the prediction of leakage rates in different zones across a network. The decision support system utilizes these models to predict the condition of pipes in individual zones, and to optimize the utilization of rehabilitation resources by targeting the areas with the highest leakage rates.

  20. Determination of leakage areas in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Keim, E. [Siemens/KWU, Erlangen (Germany)

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  1. Component external leakage and rupture frequency estimates

    International Nuclear Information System (INIS)

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results

  2. Leakage-Resilient Circuits without Computational Assumptions

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2012-01-01

    Physical cryptographic devices inadvertently leak information through numerous side-channels. Such leakage is exploited by so-called side-channel attacks, which often allow for a complete security breache. A recent trend in cryptography is to propose formal models to incorporate leakage...... on computational assumptions, our results are purely information-theoretic. In particular, we do not make use of public key encryption, which was required in all previous works...... into the model and to construct schemes that are provably secure within them. We design a general compiler that transforms any cryptographic scheme, e.g., a block-cipher, into a functionally equivalent scheme which is resilient to any continual leakage provided that the following three requirements are satisfied...

  3. Markovian Processes for Quantitative Information Leakage

    DEFF Research Database (Denmark)

    Biondi, Fabrizio

    Quantification of information leakage is a successful approach for evaluating the security of a system. It models the system to be analyzed as a channel with the secret as the input and an output as observable by the attacker as the output, and applies information theory to quantify the amount...... and randomized processes with Markovian models and to compute their information leakage for a very general model of attacker. We present the QUAIL tool that automates such analysis and is able to compute the information leakage of an imperative WHILE language. Finally, we show how to use QUAIL to analyze some...... of information transmitted through such channel, thus effectively quantifying how many bits of the secret can be inferred by the attacker by analyzing the system’s output. Channels are usually encoded as matrices of conditional probabilities, known as channel matrices. Such matrices grow exponentially...

  4. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the 13 N content in the containment atmosphere. 13 N is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/ 13 N+ 4 He. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium 13 N concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  5. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/Nl3+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  6. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1979-08-01

    The present paper deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process H1+016 → N13+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m -3 and 7 kBq m -3 for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge (Li) flow detector assembly operated at elevated pressure. (Auth.)

  7. Quantifying information leakage of randomized protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Legay, Axel; Malacaria, Pasquale

    2015-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model deterministic and probabilistic systems. By using a methodology generalizing the lattice of information approach we model refined attackers...... capable to observe the internal behavior of the system, and quantify the information leakage of such systems. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed and non-timed attacks...

  8. Quantifying Information Leakage of Randomized Protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Wasowski, Andrzej; Legay, Axel

    2013-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model and analyze the information leakage of deterministic and probabilistic systems. We show that this method generalizes the lattice...... of information approach and is a natural framework for modeling refined attackers capable to observe the internal behavior of the system. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed...

  9. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  10. The Leakage determination on corrosion fretting machine

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Hafid, Abdul; Febrianto; Prasetio, Joko; Abtokhi; Sumarno, Edy; Handoyo, Ismu; Hidayati, Nur Rahmah; Histori

    1998-01-01

    Fretting machine is an experimental loop to learn fretting corrosion phenomena wich is caused by loading and vibration. On the steam generator, one of the corrosion process that's occurred, it can be caused by vibration between tubes and bending material. Because of high flow rate inside the tube, the high frequency vibration will appeared so it can make the corrosion on bending material more faster. This process can be simulate by fretting machine. This machine has already damage because of leakage. So it will be repaired by dismantling, radiography testing and redrawing. from the result of radiography, the leakage is caused by cracking on bellows seals of the dynamic main support

  11. Angiosarcoma of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Grafino, Monica; Alves, Paula; Almeida, Margarida Mendes de; Garrido, Patricia; Hasmucrai, Direndra; Teixeira, Encarnacao; Sotto-Mayor, Renato, E-mail: mgrafino@gmail.com [Centro Hospitalar Lisboa Norte, EPE, Lisboa (Portugal)

    2016-06-01

    Angiosarcoma is a rare malignant vascular tumor. Pulmonary involvement is usually attributable to metastasis from other primary sites, primary pulmonary angiosarcoma therefore being quite uncommon. We report a case of angiosarcoma with pulmonary involvement, probably primary to the lung, which had gone untreated for more than two years. We describe this rare neoplasm and its growth, as well as the extensive local invasion and hematogenous metastasis at presentation. We also discuss its poor prognosis. (author)

  12. Histochemical alterations in one lung ventilation.

    Science.gov (United States)

    Yin, Kingsley; Gribbin, Elizabeth; Emanuel, Steven; Orndorff, Rebecca; Walker, Jean; Weese, James; Fallahnejad, Manucher

    2007-01-01

    One lung ventilation is a commonly performed surgical procedure. Although there have been several reports showing that one-lung ventilation can cause pathophysiological alterations such as pulmonary hypoxic vasoconstriction and intrapulmonary shunting, there have been virtually no reports on the effects of one-lung ventilation on lung histology. Yorkshire pigs (11-17 kg) were anesthetized, a tracheotomy performed and a tracheal tube inserted. The chest was opened and one lung ventilation (OLV), was induced by clamping of the right main bronchus. OLV was continued for 60 min before the clamp was removed and two lung ventilation (TLV) started. TLV was continued for 30 to 60 min. Blood and lung biopsies were taken immediately before OLV, 30 min and 60 min of OLV and after restoration of TLV. Histological analyses revealed that the non-ventilated lung was totally collapsed during OLV. On reventilation, there was clear evidence of vascular congestion and alveolar wall thickening at 30 min after TLV. At 60 min of TLV, there was still vascular congestion. Serum nitrite levels (as an index of nitric oxide production) showed steady decline over the course of the experimental period, reaching a significantly low level on reventilation (compared with baseline levels before OLV). Lung MPO activity (marker of neutrophil sequestration) and serum TNFalpha levels were not raised during the entire experimental period. These results suggest that there was lung vascular injury after OLV, which was associated with reduced levels of nitric oxide production and not associated with an inflammatory response.

  13. Current lung water measurement methods in man

    International Nuclear Information System (INIS)

    Basset, G.; Moreau, F.; Marsac, J.; Capitini, R.; Botter, F.

    1979-01-01

    Two kinds of tracer method are used to estimate the lung water pools differing by the tracer intake and the sector observed. Airborne intake gives an estimate of the tissues irrigated by the lung and bronchial circulation, whereas vascular intake only shows the sectors perfused by the lung flow. Either of these methods is suitable for a general or regional analysis. In general methods the tracer is followed at the lung exit on expired air for the first method, on peripheral arterial blood for the second. Regional methods imply partial or whole-lung external detection systems [fr

  14. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  15. Poloidal field leakage optimization in ETE

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Carlos Shinya; Montes, Antonio

    1996-12-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs.

  16. The concept of leakage in threat assessment.

    Science.gov (United States)

    Meloy, J Reid; O'Toole, Mary Ellen

    2011-01-01

    Leakage in the context of threat assessment is the communication to a third party of an intent to do harm to a target. Third parties are usually other people, but the means of communication vary, and include letters, diaries, journals, blogs, videos on the internet, emails, voice mails, and other social media forms of transmission. Leakage is a type of warning behavior that typically infers a preoccupation with the target, and may signal the research, planning, and implementation of an attack. Nomothetic data suggest that leakage occurs in a majority of cases of attacks on and assassinations of public figures, adult mass murders, adolescent mass murders, and school or campus shootings: very low-frequency, but catastrophic acts of intended and targeted violence. Idiographic or case data illustrate the various permutations of leakage. We discuss the operational importance of the concept, place it in the context of other warning behaviors, emphasize the need for further research, and outline risk management strategies for the mitigation of such acts of violence in both law enforcement and clinical mental health settings. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Secret rate - Privacy leakage in biometric systems

    NARCIS (Netherlands)

    Ignatenko, T.; Willems, F.M.J.

    2009-01-01

    Ahlswede and Csiszár [1993] introduced the concept of secret sharing. In their source model two terminals observe two correlated sequences. It is the objective of the terminals to form a common secret by interchanging a public message (helper data) in such a way that the secrecy leakage is

  18. Radiation leakage in nuclear ship 'MUTSU'

    International Nuclear Information System (INIS)

    Ando, Yoshio; Miyasaka, Shun-ichi; Takeuchi, Kiyoshi.

    1975-01-01

    Associated with the radiation leakage in MUTSU occurred in September 1974, this report reviews the shielding design for MUTSU, radiation measurement and inspection activities by a survey group, and 2 dimensional analysis on the behavior of fast neutrons to shielding based on Ssub(N) codes. In the first part, the purpose and the structure of the primary and the secondary shields of MUTSU are briefly illustrated. In the second part, the progress of the series of affairs is explained, starting from zero power criticality experiment, through discovery of radiation leakage in output-increasing test, sending of a survey group for various measurement and inspection, and finally to the conclusion drawn by the survey group. In the third part, various numerical analyses performed to investigate into the leakage are illustrated with their results. The transport codes used were ANISN, TWOTRAN, SPAN, and PALLAS-2DCY. As a result of those inspection and calculation, it was found that the radiation leakage was due to fast neutrons coming through the gap between the reactor vessel and the primary shield. (Aoki, K.)

  19. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  20. Poloidal field leakage optimization in ETE

    International Nuclear Information System (INIS)

    Shibata, Carlos Shinya; Montes, Antonio.

    1996-01-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs

  1. Zero leakage quantization scheme for biometric verification

    NARCIS (Netherlands)

    Groot, de J.A.; Linnartz, J.P.M.G.

    2011-01-01

    Biometrics gain increasing interest as a solution for many security issues, but privacy risks exist in case we do not protect the stored templates well. This paper presents a new verification scheme, which protects the secrets of the enrolled users. We will show that zero leakage is achieved if

  2. Lung Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Lung Emergencies Surgeries Lung Emergencies People with Marfan syndrome can be at increased risk of sudden lung ...

  3. Acoustic control of sodium leakage in valve gates of NPP

    International Nuclear Information System (INIS)

    Trykov, E.L.; Kovtun, S.N.; Anan'ev, A.A.; Yugov, S.I.

    2014-01-01

    Short description of sodium bench and acoustic investigation results on leakage monitoring of valves DN10 and DN40 are given. It is shown that acoustic method can be used successfully to control the leakages of sodium valves. Leakages on both type of valves increase the acoustic signal dispersion by 2-3 orders. For each type of valve acoustic system of leakage determination allows to conduct the preliminary graduation of signal dispersion on the sodium discharge rate. It make possible not only to record the leakage presence but also to determine the sodium discharge rate through the valve during the leakage [ru

  4. Reactor coolant pump seal leakage monitoring

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; James, W.; Shugars, H.G.

    1986-01-01

    Problems with reactor coolant pump seals have historically accounted for a large percentage of unscheduled outages. Studies performed for the Electric Power Research Institute (EPRI) have shown that the replacement of coolant pump seals has been one of the leading causes of nuclear plant unavailability over the last ten years. Failures of coolant pump seals can lead to primary coolant leakage rates of 200-500 gallons per minute into the reactor building. Airborne activity and high surface contamination levels following these failures require a major cleanup effort and increases the time and personnel exposure required to refurbish the pump seals. One of the problems in assessing seal integrity is the inability to accurately measure seal leakage. Because seal leakage flow is normally very small, it cannot be sensed directly with normal flow instrumentation, but must be inferred from several other temperature and flow measurements. In operating plants the leakage rate has been quantified with a tipping-bucket gauge, a device which indicates when one quart of water has been accumulated. The tipping-bucket gauge has been used for most rainfall-intensity monitoring. The need for a more accurate and less expensive gauge has been addressed. They have developed a drop-counter precipitation sensor has been developed and optimized. The applicability of the drop-counter device to the problem of measuring seal leakage is being investigated. If a review of system specification and known drop-counter performance indicates that this method is feasible for measuring seal leak rates, a drop-counter gauge will be fabricated and tested in the laboratory. If laboratory tests are successful the gauge will be demonstrated in a pump test loop at Ontario Hydro and evaluated under simulated plant conditions. 3 references, 2 figures

  5. Nutrition for Lung Cancer

    Science.gov (United States)

    ... Become An Advocate Volunteer Ways To Give Lung Cancer www.lung.org > Lung Health and Diseases > Lung Disease Lookup > ... Cancer Learn About Lung Cancer What Is Lung Cancer Lung Cancer Basics Causes & Risk Factors Lung Cancer Staging ...

  6. Bioprinting for vascular and vascularized tissue biofabrication.

    Science.gov (United States)

    Datta, Pallab; Ayan, Bugra; Ozbolat, Ibrahim T

    2017-03-15

    Bioprinting is a promising technology to fabricate design-specific tissue constructs due to its ability to create complex, heterocellular structures with anatomical precision. Bioprinting enables the deposition of various biologics including growth factors, cells, genes, neo-tissues and extra-cellular matrix-like hydrogels. Benefits of bioprinting have started to make a mark in the fields of tissue engineering, regenerative medicine and pharmaceutics. Specifically, in the field of tissue engineering, the creation of vascularized tissue constructs has remained a principal challenge till date. However, given the myriad advantages over other biofabrication methods, it becomes organic to expect that bioprinting can provide a viable solution for the vascularization problem, and facilitate the clinical translation of tissue engineered constructs. This article provides a comprehensive account of bioprinting of vascular and vascularized tissue constructs. The review is structured as introducing the scope of bioprinting in tissue engineering applications, key vascular anatomical features and then a thorough coverage of 3D bioprinting using extrusion-, droplet- and laser-based bioprinting for fabrication of vascular tissue constructs. The review then provides the reader with the use of bioprinting for obtaining thick vascularized tissues using sacrificial bioink materials. Current challenges are discussed, a comparative evaluation of different bioprinting modalities is presented and future prospects are provided to the reader. Biofabrication of living tissues and organs at the clinically-relevant volumes vitally depends on the integration of vascular network. Despite the great progress in traditional biofabrication approaches, building perfusable hierarchical vascular network is a major challenge. Bioprinting is an emerging technology to fabricate design-specific tissue constructs due to its ability to create complex, heterocellular structures with anatomical precision

  7. Pancreatic anastomosis leakage management following pancreaticoduodenectomy how could be manage the anastomosis leakage after pancreaticoduodenectomy?

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Tabatabei

    2015-01-01

    Full Text Available Background: Pancreatic anastomosis leakage and fistula formation following pancreaticoduodenectomy (Whipple′s procedure is a common complication. Delay in timely diagnosis and proper management is associated with high morbidity and mortality. To report our experience with management of pancreatic fistula following Whipple′s procedure. Materials and Methods: In this retrospective study, medical records of 90 patients who underwent Whipple′s procedure from 2009 to 2013 at our medical center were reviewed for documents about pancreatic anastomosis leakage and fistula formation. Results: There were 15 patients who developed pancreatico-jejunal anastomosis leakage. In 6 patients (3 males and 3 females the leakage was mild (conservative therapy was administered, but in 9 patients (6 males and 3 females, there was severe leakage. For the latter group, surgical intervention was done (2 cases underwent re-anastomosis and for 7 cases pancreatico-jejunal stump ligation was done along with drainage of the location. Conclusion: In severe pancreatic anastomotic leakage, it is better to intervene surgically as soon as possible by debridement of the distal part of the pancreas and ligation of the stump with nonabsorbable suture. Furthermore, debridement of the jejunum should be done, and the stump should be ligated thoroughly along with drainage.

  8. Incidence and management of pancreatic leakage after pancreatoduodenectomy

    NARCIS (Netherlands)

    de Castro, S. M. M.; Busch, O. R. C.; van Gulik, T. M.; Obertop, H.; Gouma, D. J.

    2005-01-01

    Background: Optimal management of severe pancreatic leakage after pancreatoduodenectomy can reduce morbidity and mortality. Completion pancreatectomy may be adequate but leads to endocrine insufficiency. This study evaluated an alternative management strategy for pancreatic leakage. Methods: Outcome

  9. Multiple leakage localization and leak size estimation in water networks

    NARCIS (Netherlands)

    Abbasi, N.; Habibi, H.; Hurkens, C.A.J.; Klabbers, M.D.; Tijsseling, A.S.; Eijndhoven, van S.J.L.

    2012-01-01

    Water distribution networks experience considerable losses due to leakage, often at multiple locations simultaneously. Leakage detection and localization based on sensor placement and online pressure monitoring could be fast and economical. Using the difference between estimated and measured

  10. Antitumor activity of ZD6126, a novel vascular-targeting agent, is enhanced when combined with ZD1839, an epidermal growth factor receptor tyrosine kinase inhibitor, and potentiates the effects of radiation in a human non-small cell lung cancer xenograft model.

    Science.gov (United States)

    Raben, David; Bianco, Cataldo; Damiano, Vincenzo; Bianco, Roberto; Melisi, Davide; Mignogna, Chiara; D'Armiento, Francesco Paolo; Cionini, Luca; Bianco, A Raffaele; Tortora, Giampaolo; Ciardiello, Fortunato; Bunn, Paul

    2004-08-01

    Targeting the tumor vasculature may offer an alternative or complementary therapeutic approach to targeting growth factor signaling in lung cancer. The aim of these studies was to evaluate the antitumor effects in vivo of the combination of ZD6126, a tumor-selective vascular-targeting agent; ZD1839 (gefitinib, Iressa), an epidermal growth factor receptor tyrosine kinase inhibitor; and ionizing radiation in the treatment of non-small cell lung cancer xenograft model. Athymic nude mice with established flank A549 human non-small cell lung cancer xenograft model xenografts were treated with fractionated radiation therapy, ZD6126, ZD1839, or combinations of each treatment. ZD6126 (150 mg/kg) was given i.p. the day after each course of radiation. Animals treated with ZD1839 received 100 mg/kg per dose per animal, 5 or 7 days/wk for 2 weeks. Immunohistochemistry was done to evaluate the effects on tumor growth using an anti-Ki67 monoclonal antibody. Effects on tumor-induced vascularization were quantified using an anti-factor VIII-related antigen monoclonal antibody. ZD6126 attenuated the growth of human A549 flank xenografts compared with untreated animals. Marked antitumor effects were observed when animals were treated with a combination of ZD6126 and fractionated radiation therapy with protracted tumor regression. ZD6126 + ZD1839 resulted in a greater tumor growth delay than either agent alone. Similar additive effects were seen with ZD1839 + fractionated radiation. Finally, the addition of ZD6126 to ZD1839 and radiation therapy seemed to further improve tumor growth control, with a significant tumor growth delay compared with animals treated with single agent or with double combinations. Immunohistochemistry showed that ZD1839 induced a marked reduction in A549 tumor cell proliferation. Both ZD1839 and ZD6126 treatment substantially reduced tumor-induced angiogenesis. ZD6126 caused marked vessel destruction through loss of endothelial cells and thrombosis

  11. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  12. Performance-based containment leakage testing

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1995-01-01

    The U.S. Nuclear Regulatory Commission (NRC) is reviewing regulatory requirements in an effort to revise those that are marginal to safety but impose significant burdens on licensees. Identification of requirements marginal to safety and development and evaluation of alternatives utilize the NRC safety goals and insights from probabilistic risk assessments (PRAs). Since earlier studies found design-basis containment leakage to be a minor contributor to reactor accident risk, containment leakage testing has been selected as a candidate for change in regulations. This paper summarizes the technical analyses supporting the NRC proposal to amend Appendix J of 10 CFR Part 50 as its first effort to decrease unnecessary regulatory burdens on licensees

  13. Methane leakage in natural gas operations

    International Nuclear Information System (INIS)

    Jennervik, A.

    1992-01-01

    The world gas industry is efficient in conservation of natural gas within its systems. As the influence of methane as an infra-red absorbent gas has been more widely recognized, the considerations of methane's greenhouse effect has become vitally important to gas companies around the world. The industry is universally environmentally conscious. natural gas transmission and distribution companies want to maintain their image as suppliers of clean fuel. Further reductions in methane leakage --- particularly in older distribution systems --- can, should and will be pursued. Unfortunately, there has been little exchange of views on methane leakages between commentators on environmental matters and gas companies and organizations. There is absolutely no need for the industry to avoid the issue of greenhouse gases. Without industry involvement, the environmental debate concerning fossil fuels could lead to selective interpretation of scientific views and available evidence. Companies and authorities would be presented with confusing, contradictory evidence on which to base policy approaches and regulations

  14. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  15. Numerical investigation of tip leakage vortex

    OpenAIRE

    Fredriksen, Vegard

    2017-01-01

    The Kaplan turbine has a small clearance gap between the blade tip and casing to allow the blades to rotate freely. This clearance gap is the cause of an undesirable Tip Leakage Vortex (TLV). A TLV might reduce the turbine efficiency, erode the turbine blades or cause instabilities for the power output. A literature study indicated that the tip clearance gap was a critical parameter affecting the behavior of the TLV. A research gap was observed for an operating Kaplan turbine where the ...

  16. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  17. NF1 Signal Transduction and Vascular Dysfunction

    Science.gov (United States)

    2015-05-01

    microenvironment that promotes much of the pathology associated with the disease . Moreover we hypothesize that a mechanistic consequence of the loss...obliteration of the normal red pulp architecture. In addition, we found significant peri-aveolar and peri-vascular inflammatory infiltrates in the lung...the mouse model of NF1 disease in the endothelium we proposed and have done experiments investigating the loss of endothelial NF1 in the adult

  18. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  19. [Lung Abscess with Acute Empyema Which Improved after Performing by Video Assissted Thoracic Surgery( Including Pneumonotomy and Lung Abscess Drainage);Report of a Case].

    Science.gov (United States)

    Gabe, Atsushi; Nagamine, Naoji

    2017-05-01

    We herein report the case of a patient demonstrating a lung abscess with acute empyema which improved after performing pnemumonotomy and lung abscess drainage. A 60-year-old male was referred to our hospital to receive treatment for a lung abscess with acute empyema. At surgery, the lung parenchyma was slightly torn with pus leakage. After drainage of lung abscess by enlarging the injured part, curettage in the thoracic cavity and decortication were performed. The postoperative course was uneventful. Direct drainage of an abscess into the thoracic cavity is thought to be a choice for the treatment of lung abscesses.

  20. Radiation induced leakage current and stress induced leakage current in ultra-thin gate oxides

    International Nuclear Information System (INIS)

    Ceschia, M.; Paccagnella, A.; Cester, A.; Scarpa, A.

    1998-01-01

    Low-field leakage current has been measured in thin oxides after exposure to ionizing radiation. This Radiation Induced Leakage Current (RILC) can be described as an inelastic tunneling process mediated by neutral traps in the oxide, with an energy loss of about 1 eV. The neutral trap distribution is influenced by the oxide field applied during irradiation, thus indicating that the precursors of the neutral defects are charged, likely being defects associated to trapped holes. The maximum leakage current is found under zero-field condition during irradiation, and it rapidly decreases as the field is enhanced, due to a displacement of the defect distribution across the oxide towards the cathodic interface. The RILC kinetics are linear with the cumulative dose, in contrast with the power law found on electrically stressed devices

  1. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  2. Leakage warning system for flexible underwater pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, E; Bernstein, L

    1985-08-01

    Underwater pipelines for unloading oil tankers, e.g. in 30 km distance from the harbour site, are required to be flexible and require supervision. This is done by implementation of oil sensitive sensors between the inner rubber tube and the following impregnated textile layer. The generated sensor signals, influenced by leak oil, have to be wireless transmitted from 150 meters under water to the supervisory station at the coast. Sensor configurations are described, to derive the point of the leakage from the topologized warning signals.

  3. Facepiece leakage and fitting of respirators

    International Nuclear Information System (INIS)

    White, J.M.

    1978-05-01

    The ways in which airborne contaminants can penetrate respirators and the factors which affect the fit of respirators are discussed. The fit of the respirator to the face is shown to be the most critical factor affecting the protection achieved by the user. Qualitative and quantitative fit testing techniques are described and their application to industrial respirator programs is examined. Quantitative measurement of the leakage of a respirator while worn can be used to numerically indicate the protection achieved. These numbers, often referred to as protection factors, are sometimes used as the basis for selecting suitable respirators and this practice is reviewed. (author)

  4. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  5. Unusual dialysate leakage complicating peritoneal dialysis

    International Nuclear Information System (INIS)

    Chiu, Jainn-Shiun; Yu, Fu-Chiu; Chen, Chiou-An; Wang, Yuh-Feng

    2006-01-01

    A 16-year-old female who had end-stage renal disease on 2-month continuous ambulatory peritoneal dialysis (CAPD) presented with perineal pain 4 days before admission. The physical examination revealed bilateral labial edema. Peritoneal scintigraphy was requested after infusing 2 L peritoneal dialysate with direct administration of 370 MBq (10mCi) technetium-99m diethylenetriamine pentra-acetic acid into peritoneal cavity via Tenckhoff catheter. Radioactive uptake from right inguinal to labial region was clearly demonstrated, and this indicated the site of peritoneal leakage. After surgical intervention unilaterally, she continued CAPD without any recurrence (au)

  6. Lung scintigraphy

    International Nuclear Information System (INIS)

    Dalenz, Roberto.

    1994-01-01

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies

  7. Epithelioid lung haenangioendiothelioma

    International Nuclear Information System (INIS)

    Finozzi, V.; Andrade, E.; Campos, N.; Pizarrosa, C.

    2000-01-01

    The first national case of epithelioid lung haenangioendiothelioma concerned a 60 years old woman. Clinical picture and TC diagnosis showed a vascularized tumor producing persistent haenoptoic expectoration.It is necessary to be acquainted with it for the purpose of a differentiated diagnosis. It is a tumor with specific immunohistochemical markers against factor V III.Treatment consisted of surgical resection. Concerning its classification it is situated at the limit between benign and malignant, prognosis is usually good, but evolution is slow, extending for over 20 years

  8. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  9. Leakage in the Juelich research reactor

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    On August 17, 1978, a leakage occurred in the DIDO research reactor. Early in the afternoon of this day, the valves of the coolant loop had been checked with the reactor shut off. When the mechanics wanted to oil a tight valve and drilled a hole in the valve cover for this, heavy water started to leak (leakage in the valve membrane). The mechanics left the shielded valve space at once; directly after having a shower, they underwent a radiation protection examination. It was found that none of the mechanics had been exposed to an excessive dose. When other mechanics in protective suits had closed the leak in the valve, a total of 150 liters had leaked into the sump pump at the valve entrance. They were pumped back into the cooling system. About 5 liters of water were evaporated and, via the stack, escaped into the environment. The activity released was about 40 curie; this is less than the permissible amount of 60 curie per week during normal operation. Neither the KFA personnel nor the inhabitants of Juelich and its surroundings were in danger at any moment. Calculations so far yield a maximum radiation exposure below 1mrem at the point of maximum exposure. The cooling circuit could be entered again only one day after the incident. The present shut-off phase of the reactor is not unduly prolonged by this accident. (orig./HP) [de

  10. Leakage detection device for weld portion

    International Nuclear Information System (INIS)

    Shinkawa, Toshio; Setokuchi, Sadayuki.

    1994-01-01

    The present invention concerns leakage detection device for weld portions, for example, in a nuclear reactor cavity, which can rapidly detect by remote control. That is, a detection device capable of self running and stopping on a guide rail along a weld line is disposed. The detection device comprises a coating mechanism for automatically coating soap water to the weld portion, a vacuum box capable of evacuating the coated surface and a camera for detecting the presence or absence of the soap bubbles generated under the evacuation. Such a device can conduct, by remote control, self running/stopping along with the weld line, coating of the soap water, settling of the vacuum box and confirmation and recording of foaming by using a television monitor. Accordingly, leakage in the weld portion in the reactor cavity or the like can be inspected. As a result, it greatly contributes to improvement of danger upon worker's operation at high place, detection accuracy and reliability of detection and shortening of operation period. (I.S.)

  11. Leakage detection system in nuclear reactor container

    International Nuclear Information System (INIS)

    Kurosawa, Masahiko.

    1993-01-01

    The present invention comprises an injection means for adding radioactive materials to coolants in a container cooler, a gamma ray amplitude analyzer connected to coolant pipelines and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to a drain water sump and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to various kinds of pipelines and a means for recording/transferring the data of the result of the measurement, and a data processing means for comparing and analyzing the measured data of each of the gamma ray amplitude analyzers inputted from each of date recording/transferring means. The gamma ray amplitude analysis for each of the pipelines and drain water sump are conducted at an appropriate frequency, and the measured data are compared and analyzed, to improve the detection accuracy for a trace amount of leakage from each of the pressure pipelines and the container cooler coolant pipelines, thereby enabling to specify the pipeline having leakage. Maintenance efficiency is improved, and severe rupture accident in each of pressure pipelines is prevented previously. (N.H.)

  12. 1α,25-Dihydroxyvitamin D3 Ameliorates Seawater Aspiration-Induced Acute Lung Injury via NF-κB and RhoA/Rho Kinase Pathways

    Science.gov (United States)

    Liu, Wei; Wang, Li; Luo, Ying; Li, Zhichao; Jin, Faguang

    2014-01-01

    Introduction Inflammation and pulmonary edema are involved in the pathogenesis of seawater aspiration-induced acute lung injury (ALI). Although several studies have reported that 1α,25-Dihydroxyvitamin D3 (calcitriol) suppresses inflammation, it has not been confirmed to be effective in seawater aspiration-induced ALI. Thus, we investigated the effect of calcitriol on seawater aspiration-induced ALI and explored the probable mechanism. Methods Male SD rats receiving different doses of calcitriol or not, underwent seawater instillation. Then lung samples were collected at 4 h for analysis. In addition, A549 cells and rat pulmonary microvascular endothelial cells (RPMVECs) were cultured with calcitriol or not and then stimulated with 25% seawater for 40 min. After these treatments, cells samples were collected for analysis. Results Results from real-time PCR showed that seawater stimulation up-regulated the expression of vitamin D receptor in lung tissues, A549 cells and RPMVECs. Seawater stimulation also activates NF-κB and RhoA/Rho kinase pathways. However, we found that pretreatment with calcitriol significantly inhibited the activation of NF-κB and RhoA/Rho kinase pathways. Meanwhile, treatment of calcitriol also improved lung histopathologic changes, reduced inflammation, lung edema and vascular leakage. Conclusions These results demonstrated that NF-κB and RhoA/Rho kinase pathways are critical in the development of lung inflammation and pulmonary edema and that treatment with calcitriol could ameliorate seawater aspiration-induced ALI, which was probably through the inhibition of NF-κB and RhoA/Rho kinase pathways. PMID:25118599

  13. Calculation of transformers leakage reactance using electromagnetic energy technique

    International Nuclear Information System (INIS)

    Feiz, J.; Mohseni, H.; Sabet Marzooghi, S.; Naderian Jahromi, A.

    2004-01-01

    Determination of transformer leakage reactance using magnetic cores has long been an area of interest to engineers involved in the design of power and distribution transformers. This is required for predicting the performance of transformers before actual assembly of the transformers. In this paper a closed form solution technique applicable to the leakage reactance calculations for transformers is presented. An emphasis is on the development of a simple method to calculate the leakage reactance of the distribution transformers and smaller transformers. Energy technique procedure for computing the leakage reactances in distribution transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using test. This paper presents a novel technique for calculation of the leakage inductance in different parts of the transformer using the electromagnetic stored energy

  14. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  15. Device for preventing leakage of coolant in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Kobayashi, Yukio; Sekiguchi, Mamoru; Yoshida, Hideo.

    1975-01-01

    Object: To prevent leakage of coolant from between lower tie plate and channel box without causing deformation of the channel box and also without the possibility of disturbing the installation and removal of the box by the provision of a thin plate provided with leakage holes for the lower tie plate. Structure: Static water pressure within the lower tie plate is adapted to act upon the bear side of a flat plate for leakage prevention through leakage holes formed in the tie plate, thus urging the flat plate against the channel box inner surface. Meanwhile, static water pressure having been led through the leakage holes in the flat plate is adapted to press the flat plate in the vertical direction, thus urging the flat plate against the channel box inner surface and thereby preventing leakage of the coolant through a gap between the channel box and lower tie plate. (Yoshino, Y.)

  16. Juxta-Vascular Pulmonary Nodule Segmentation in PET-CT Imaging Based on an LBF Active Contour Model with Information Entropy and Joint Vector

    Directory of Open Access Journals (Sweden)

    Rui Hao

    2018-01-01

    Full Text Available The accurate segmentation of pulmonary nodules is an important preprocessing step in computer-aided diagnoses of lung cancers. However, the existing segmentation methods may cause the problem of edge leakage and cannot segment juxta-vascular pulmonary nodules accurately. To address this problem, a novel automatic segmentation method based on an LBF active contour model with information entropy and joint vector is proposed in this paper. Our method extracts the interest area of pulmonary nodules by a standard uptake value (SUV in Positron Emission Tomography (PET images, and automatic threshold iteration is used to construct an initial contour roughly. The SUV information entropy and the gray-value joint vector of Positron Emission Tomography–Computed Tomography (PET-CT images are calculated to drive the evolution of contour curve. At the edge of pulmonary nodules, evolution will be stopped and accurate results of pulmonary nodule segmentation can be obtained. Experimental results show that our method can achieve 92.35% average dice similarity coefficient, 2.19 mm Hausdorff distance, and 3.33% false positive with the manual segmentation results. Compared with the existing methods, our proposed method that segments juxta-vascular pulmonary nodules in PET-CT images is more accurate and efficient.

  17. Lung density

    DEFF Research Database (Denmark)

    Garnett, E S; Webber, C E; Coates, G

    1977-01-01

    The density of a defined volume of the human lung can be measured in vivo by a new noninvasive technique. A beam of gamma-rays is directed at the lung and, by measuring the scattered gamma-rays, lung density is calculated. The density in the lower lobe of the right lung in normal man during quiet...... breathing in the sitting position ranged from 0.25 to 0.37 g.cm-3. Subnormal values were found in patients with emphsema. In patients with pulmonary congestion and edema, lung density values ranged from 0.33 to 0.93 g.cm-3. The lung density measurement correlated well with the findings in chest radiographs...... but the lung density values were more sensitive indices. This was particularly evident in serial observations of individual patients....

  18. What Is Lung Cancer?

    Science.gov (United States)

    ... Shareable Graphics Infographics “African-American Men and Lung Cancer” “Lung Cancer Is the Biggest Cancer Killer in Both ... starts in the lungs, it is called lung cancer. Lung cancer begins in the lungs and may spread ...

  19. Abscess in the Lungs

    Science.gov (United States)

    ... Home Lung and Airway Disorders Abscess in the Lungs Abscess in the Lungs Causes Symptoms Diagnosis Treatment Resources ... here for the Professional Version Abscess in the Lungs Abscess in the Lungs A lung abscess is a ...

  20. Topological leakage detection and freeze-and-grow propagation for improved CT-based airway segmentation

    Science.gov (United States)

    Nadeem, Syed Ahmed; Hoffman, Eric A.; Sieren, Jered P.; Saha, Punam K.

    2018-03-01

    Numerous large multi-center studies are incorporating the use of computed tomography (CT)-based characterization of the lung parenchyma and bronchial tree to understand chronic obstructive pulmonary disease status and progression. To the best of our knowledge, there are no fully automated airway tree segmentation methods, free of the need for user review. A failure in even a fraction of segmentation results necessitates manual revision of all segmentation masks which is laborious considering the thousands of image data sets evaluated in large studies. In this paper, we present a novel CT-based airway tree segmentation algorithm using topological leakage detection and freeze-and-grow propagation. The method is fully automated requiring no manual inputs or post-segmentation editing. It uses simple intensity-based connectivity and a freeze-and-grow propagation algorithm to iteratively grow the airway tree starting from an initial seed inside the trachea. It begins with a conservative parameter and then, gradually shifts toward more generous parameter values. The method was applied on chest CT scans of fifteen subjects at total lung capacity. Airway segmentation results were qualitatively assessed and performed comparably to established airway segmentation method with no major visual leakages.

  1. Radiologic assessment of spinal CSF leakage in spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Han, Chang Jin; Kim, Ji Hyung; Kim, Jang Sung; Kim, Sun Yong; Suh, Jung Ho

    1999-01-01

    To assess the usefulness of imaging modalities in the detection of spinal CSF leakage in spontaneous intracranial hypotension. Fifteen patients who complained of postural headache without any preceding cause showed typical brain MR findings of intracranial hypotension, including radiologically confirmed CSF leakage. All fifteen underwent brain MRI and radionuclide cisternography. CT myelography was performed in eight patients and spinal MRI in six. Medical records, imaging findings and the incidence of spinal CSF leakage during each modality were retrospectively reviewed. CSF leakage was most common at the cervicothoracic junction, where in seven of 15 cases it was seen on radionuclide cisternography as increased focal paraspinal activity. Leakage was noted at the mid-tho-racic level in three patients, at the upper thoracic level in two, and at the cervical and lumbar levels in the remaining two. In two patients multiple CSF leaks were noted, and in all, early radioactive accumulation in the bladder was visualized. CT myelography revealed extrathecal and paraspinal contrast leakage in three of eight patients, and among those who underwent spinal MRI, dural enhancement was observed at the site of CSF leakage in all six, abnormal CSF signal in the neural foramen in one, and epidural CSF collection in one. Radionuclide cisternography is a useful method for the detection of CSF leakage in spontaneous intracranial hypotension. CT myelography and spinal MRI help determine the precise location of leakage

  2. Particle and radiation leakage importance: definition, analysis, and interpretation

    International Nuclear Information System (INIS)

    Cacuci, D.G.; Wagschal, J.J.; Yaari, A.

    1982-01-01

    The concept of leakage importance function has been introduced and analyzed for physical systems governed by the Boltzmann transport equation. This leakage importance function represents a measure of the relative importance of source particles located at every point in phase space in contributing to the leakage and provides insight regarding the specific physical process that leads to leakage. The equation satisfied by the leakage importance function has been derived by using adjoint operators. It has been shown that procedures that are customarily used to derive an equation obeyed by an importance function suitable for an integral parameter such as a detector response or an eigenvalue lead to difficulties when directly applied to derive an equation obeyed by the leakage importance function. This is because, although leakage is also an integral parameter (i.e., a functional of the forward flux density), leakage is expressed in terms of a surface integral rather than in terms of volume integrals such as those appearing in expressions of detector responses or eigenvalues. Therefore, a procedure that departs from the customary course has been devised to derive the equation satisfied by the leakage importance function

  3. Radionuclide diagnosis of pulmonary capillary protein leakage

    International Nuclear Information System (INIS)

    Creutzig, H.; Sturm, J.A.; Schober, O.; Nerlich, M.L.; Kant, C.J.; Medizinische Hochschule Hannover

    1984-01-01

    Pulmonary extravascular albumin extra-vasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques. (orig.) [de

  4. Fluid leakage near the percolation threshold

    Science.gov (United States)

    Dapp, Wolf B.; Müser, Martin H.

    2016-02-01

    Percolation is a concept widely used in many fields of research and refers to the propagation of substances through porous media (e.g., coffee filtering), or the behaviour of complex networks (e.g., spreading of diseases). Percolation theory asserts that most percolative processes are universal, that is, the emergent powerlaws only depend on the general, statistical features of the macroscopic system, but not on specific details of the random realisation. In contrast, our computer simulations of the leakage through a seal—applying common assumptions of elasticity, contact mechanics, and fluid dynamics—show that the critical behaviour (how the flow ceases near the sealing point) solely depends on the microscopic details of the last constriction. It appears fundamentally impossible to accurately predict from statistical properties of the surfaces alone how strongly we have to tighten a water tap to make it stop dripping and also how it starts dripping once we loosen it again.

  5. Anomaly detection using magnetic flux leakage technology

    Energy Technology Data Exchange (ETDEWEB)

    Rempel, Raymond G. [BJ Pipeline Inspection Services, Alberta (Canada)

    2005-07-01

    There are many aspects to properly assessing the integrity of a pipeline. In-line-Inspection (ILI) tools, in particular those that employ the advanced use of Magnetic Flux Leakage (MFL) technology, provide a valuable means of achieving required up-to-date knowledge of a pipeline. More prevalent use of High Resolution MFL In-Line-Inspection tools is growing the knowledge base that leads to more reliable and accurate identification of anomalies in a pipeline, thus, minimizing the need for expensive verification excavations. Accurate assessment of pipeline anomalies can improve the decision making process within an Integrity Management Program and excavation programs can then focus on required repairs instead of calibration or exploratory digs. Utilizing the information from an MFL ILI inspection is not only cost effective but, as well, can also prove to be an extremely valuable building block of a Pipeline Integrity Management Program. (author)

  6. Leakages and pressure relation: an experimental research

    Directory of Open Access Journals (Sweden)

    F. De Paola

    2012-11-01

    Full Text Available Leaks in water systems are presently a frequent and increasing event that involves cost increase and poor service, not compliant to quality standards and modern management criteria. The most recent data available in Italy, resumed into the report issued by Control Committee for Water Resources Use (CONVIRI, shows leakages with an average value of 37%. It is therefore important, for maintenance perspective, to investigate occurrence and evolution of water leaks and the analytical link between leaks Qp and network pressure P, for a reliable calibration of water networks quali-quantitative simulation models. The present work reports the first results of an experimental campaign started at Laboratory of Hydraulics of Department of Hydraulics, Geotechnical and Environmental Engineering of University of Naples Federico II in order to analyze the features of Qp(P relation, which are compared with other results issued in literature.

  7. Potential gonadal dose from leakage radiation?

    International Nuclear Information System (INIS)

    Nicholson, R.A.

    1995-01-01

    The author draws attention to the potential dangers of leakage radiation from mobile image intensifier units, and points out that during interventional urological procedures, radiation from below the urologist's knees may irradiate male gonads without being intercepted by protective aprons. Results are presented for a Shimatzu WHA mobile II, phantom doses being measured with an ionization chamber. Dose rates measured in the male gonad position were compared with rates at waist level behind a 0.35 mm lead equivalent shielding and dose rates at collar level outside the lead apron. Results are also presented of a study on the effect on gonad dose of a) adding 0.7 mm lead shielding to the tube housing and b) adding 0.7 mm lead and removing the spacer cone to reduce scatter. Results show that it is possible for gonad doses to be comparable with those assumed for the eyes, rather than the body. (Author)

  8. Acoustic emission generated by fluid leakage

    International Nuclear Information System (INIS)

    Kim, H.C.

    1987-01-01

    The noise generated by the leaking saturated steam and subcooled water form various sizes of hole has been measured as function of leak rate and stagnation pressure. Acoustic emission (proportinal to root mean sguare voltage) is shown to be proportional to the leak rate and stagnation pressure. A transition of acoustic emission power is observed at the stagnation pressure 0.185 MPa associated with the transition to the critical flow state. Substantially higher acoustic emission power generated by the subcooled water leakage is attributed to the flashing source involving the phase transformation and volume expansion. The relative amplitude of noise spectrum becomes more spiky as the leak rate and stagnation pressure increased. (Author)

  9. Vascular effects of multiwalled carbon nanotubes in dyslipidemic ApoE-/- mice and cultured endothelial cells

    DEFF Research Database (Denmark)

    Cao, Yi; Jacobsen, Nicklas Raun; Danielsen, Pernille Høgh

    2014-01-01

    Accumulating evidences indicate that pulmonary exposure to carbon nanotubes (CNTs) is associated with increased risk of lung diseases, whereas the effect on the vascular system is less studied. We investigated vascular effects of 2 types of multiwalled CNTs (MWCNTs) in apolipoprotein E(-/-) mice,...

  10. Vascular grading of angiogenesis

    DEFF Research Database (Denmark)

    Hansen, S; Grabau, D A; Sørensen, Flemming Brandt

    2000-01-01

    The study aimed to evaluate the prognostic value of angiogenesis by vascular grading of primary breast tumours, and to evaluate the prognostic impact of adding the vascular grade to the Nottingham Prognostic Index (NPI). The investigation included 836 patients. The median follow-up time was 11...... years and 4 months. The microvessels were immunohistochemically stained by antibodies against CD34. Angiogenesis was graded semiquantitatively by subjective scoring into three groups according to the expected number of microvessels in the most vascular tumour area. The vascular grading between observers...... for 24% of the patients, who had a shift in prognostic group, as compared to NPI, and implied a better prognostic dissemination. We concluded that the angiogenesis determined by vascular grading has independent prognostic value of clinical relevance for patients with breast cancer....

  11. Vascular grading of angiogenesis

    DEFF Research Database (Denmark)

    Hansen, S; Grabau, D A; Sørensen, Flemming Brandt

    2000-01-01

    The study aimed to evaluate the prognostic value of angiogenesis by vascular grading of primary breast tumours, and to evaluate the prognostic impact of adding the vascular grade to the Nottingham Prognostic Index (NPI). The investigation included 836 patients. The median follow-up time was 11...... years and 4 months. The microvessels were immunohistochemically stained by antibodies against CD34. Angiogenesis was graded semiquantitatively by subjective scoring into three groups according to the expected number of microvessels in the most vascular tumour area. The vascular grading between observers...... impact for 24% of the patients, who had a shift in prognostic group, as compared to NPI, and implied a better prognostic dissemination. We concluded that the angiogenesis determined by vascular grading has independent prognostic value of clinical relevance for patients with breast cancer....

  12. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage.

    Science.gov (United States)

    Braun, Stefan; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, Heiko; Hoernke, Maria

    2018-01-23

    The mode of action of membrane-active molecules, such as antimicrobial, anticancer, cell penetrating, and fusion peptides and their synthetic mimics, transfection agents, drug permeation enhancers, and biological signaling molecules (e.g., quorum sensing), involves either the general or local destabilization of the target membrane or the formation of defined, rather stable pores. Some effects aim at killing the cell, while others need to be limited in space and time to avoid serious damage. Biological tests reveal translocation of compounds and cell death but do not provide a detailed, mechanistic, and quantitative understanding of the modes of action and their molecular basis. Model membrane studies of membrane leakage have been used for decades to tackle this issue, but their interpretation in terms of biology has remained challenging and often quite limited. Here we compare two recent, powerful protocols to study model membrane leakage: the microscopic detection of dye influx into giant liposomes and time-correlated single photon counting experiments to characterize dye efflux from large unilamellar vesicles. A statistical treatment of both data sets does not only harmonize apparent discrepancies but also makes us aware of principal issues that have been confusing the interpretation of model membrane leakage data so far. Moreover, our study reveals a fundamental difference between nano- and microscale systems that needs to be taken into account when conclusions about microscale objects, such as cells, are drawn from nanoscale models.

  13. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  14. Theory and Practice of a Leakage Resilient Masking Scheme

    DEFF Research Database (Denmark)

    Balasch, Josep; Faust, Sebastian; Gierlichs, Benedikt

    2012-01-01

    A recent trend in cryptography is to formally prove the leakage resilience of cryptographic implementations – that is, one formally shows that a scheme remains provably secure even in the presence of side channel leakage. Although many of the proposed schemes are secure in a surprisingly strong m...

  15. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  16. Leakage-Resilient Cryptography from the Inner-Product Extractor

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2011-01-01

    We present a generic method to secure various widely-used cryptosystems against arbitrary side-channel leakage, as long as the leakage adheres three restrictions: first, it is bounded per observation but in total can be arbitrary large. Second, memory parts leak independently, and, third, the ran...

  17. Anastomotic leakage after anterior resection for rectal cancer

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    On the basis of the literature about anastomotic leakage after anterior resection for rectal cancer a review is presented of the frequency, potential risk factors and consequences of leakage. The risk factors are evaluated according to the level of scientific evidence of the individual background...

  18. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  19. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  20. Hunting the unknown: White-box database leakage detection

    NARCIS (Netherlands)

    Costante, E.; Hartog, den J.I.; Petkovic, M.; Etalle, S.; Pechenizkiy, M.; Atluri, V.; Pernul, G.

    2014-01-01

    Data leakage causes significant losses and privacy breaches worldwide. In this paper we present a white-box data leakage detection system to spot anomalies in database transactions. We argue that our approach represents a major leap forward w.r.t. previous work because: i) it significantly decreases

  1. Determination of Unidentified Leakage Using a Kalman Smoother

    International Nuclear Information System (INIS)

    Jang, Soek Bo; Heo, Gyunyoung; Ra, Insik; Han, Jeonghyun; Lee, Seon Woo

    2008-01-01

    Since the safety significance of leaks from the RCS can widely vary depending on the source of the leak as well as the leak rate, the detection of the leakage is an important issue. The leakage is classified into 1) identified leakage which is defined as leakage into closed systems such as pump seal or valve packing leaks that can be captured, and 2) unidentified leakage which is all other leakage. The unidentified leakage is typically determined by the RCS inventory balance method which is based on NUREG-1107. Since the accuracy of leak rate calculation is dependent of the plant operating condition, the change in the RCS temperature, inventory, and the transient operating condition should be avoided during the measurement period. Nevertheless, the operation of the makeup of the borated water into the RCS and the diversion of the inventory to the outside of the RCS boundary makes it difficult to maintain the plant stable over an hour. Due to the large fluctuation of the calculated leak rate, it is sometimes hard to know the trend of the leakage as well as the instantaneous leak rate. Any fluctuation of operating conditions can results in unreliable leak rate. This study proposes a new way of determining the unidentified leak rate using a Kalman filter and smoother technique. The proposed algorithm enhances the accuracy of the leak rate calculation not only for the steady state operations but also for transients in a well timed manner

  2. Lung Cancer

    International Nuclear Information System (INIS)

    Maghfoor, Irfan; Perry, M.C.

    2005-01-01

    Lung cancer is the leading cause of cancer-related mortality. Since tobacco smoking is the cause in vast majority of cases, the incidence of lung cancer is expected to rise in those countries with high or rising incidence of tobacco smoking. Even though population at a risk of developing lung cancer are easily identified, mass screening for lung cancer is not supported by currently available evidence. In case of non-small cell lung cancer, a cure may be possible with surgical resection followed by post-operative chemotherapy in those diagnosed at an early stage. A small minority of patients who present with locally advanced disease may also benefit from preoperative chemotherapy and/or radiation therapy to down stage the tumor to render it potentially operable. In a vast majority of patients, however, lung cancer presents at an advanced stage and a cure is not possible with currently available therapeutic strategies. Similarly small cell lung cancer confined to one hemi-thorax may be curable with a combination of chemotherapy and thoracic irradiation followed by prophylactic cranial irradiation, if complete remission is achieved at the primary site. Small cell lung cancer that is spread beyond the confines of one hemi-thorax is however, considered incurable. In this era of molecular targeted therapies, new agents are constantly undergoing pre-clinical and clinical testing with the aim of targeting the molecular pathways thought to involved in etiology and pathogenesis of lung cancer. (author)

  3. Failure analysis of leakage current in plastic encapsulated packages

    International Nuclear Information System (INIS)

    Hu, S.J.; Cheang, F.T.

    1989-12-01

    Plastic encapsulated packages exhibit high leakage current after a few hundred hours steam pressure pot test. The present study investigates two possible sources of leakage current, the mold compound and the lead frame tape used for taping the lead frame fingers. The results of the study indicate that the leakage current is independent of the frame and is not caused by the mold compound. The data further indicates that it is the ionic contents and acrylic-based adhesive layer of the lead frame tapes which cause the leakage current. To eliminate the leakage current, lead frame tape with low ionic contents and non acrylic-based adhesive should be used. (author). 1 fig., 2 tabs, 3 graphs

  4. An objective comparison of leakage between commonly used earplugs.

    Science.gov (United States)

    Alt, Jeremiah A; Collins, William O

    2012-01-01

    We sought to determine the efficacy of commonly used earplugs using an anatomically correct ear model. The total volume and rate of water that leaked past the earplug and subsequent defect in the tympanic membrane over separately measured 30, 60, 120, and 180-second intervals were recorded. Scenarios tested included a control with no earplug, custom molded earplug (Precision Laboratories, Orlando, FL), Mack's plug (Warren, MI), Doc's plug (Santa Cruz, CA), and cotton balls coated with petroleum jelly. All plugs tested resulted in less leakage at all time points when compared with no plug (P leakage when compared with the cotton ball coated with petroleum jelly (P leakage compared with the customized plug (P leakage than the cotton plug (P leakage rate (f(4,45) = 94 [P water exposure should be minimized, then use of earplugs, particularly the moldable variety, merits further consideration. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. PERFORMANCE OF LEAKAGE POWER MINIMIZATION TECHNIQUE FOR CMOS VLSI TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    T. Tharaneeswaran

    2012-06-01

    Full Text Available Leakage power of CMOS VLSI Technology is a great concern. To reduce leakage power in CMOS circuits, a Leakage Power Minimiza-tion Technique (LPMT is implemented in this paper. Leakage cur-rents are monitored and compared. The Comparator kicks the charge pump to give body voltage (Vbody. Simulations of these circuits are done using TSMC 0.35µm technology with various operating temper-atures. Current steering Digital-to-Analog Converter (CSDAC is used as test core to validate the idea. The Test core (eg.8-bit CSDAC had power consumption of 347.63 mW. LPMT circuit alone consumes power of 6.3405 mW. This technique results in reduction of leakage power of 8-bit CSDAC by 5.51mW and increases the reliability of test core. Mentor Graphics ELDO and EZ-wave are used for simulations.

  6. Leakage current characteristics of the multiple metal alloy nanodot memory

    International Nuclear Information System (INIS)

    Lee, Gae Hun; Lee, Jung Min; Yang, Hyung Jun; Song, Yun Heub; Bea, Ji Chel; Tanaka, Tetsu

    2010-01-01

    The leakage current characteristics of a multiple metal alloy nanodot device for a nonvolatile random access memory using FePt materials are investigated. Several annealing conditions are evaluated and optimized to suppress the leakage current and to better the memory characterisctics. This work confirmed that the annealing condition of 700 .deg. C in a high vacuum ambience (under 1 x 10 -5 Pa) simultaneously provided good cell characteristics from a high dot density of over 1 x 10 13 /cm 2 and a low leakage current. In addition, a smaller nanodot diameter was found to give a lower leakage current for the multiple nanodot memory. Finally, for the proposed annealing condition, the quadruple FePt multiple nanodot memory with a 2-nm dot diameter provided good leakage current characteristics, showing a threshold voltage shift of under 5% at an initial retention stage of 1000 sec.

  7. Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current

    Directory of Open Access Journals (Sweden)

    Bing Luo

    2012-07-01

    Full Text Available In this paper, an artificial pollution test is carried out to study the leakage current of porcelain insulators. Fractal theory is adopted to extract the characteristics hidden in leakage current waveforms. Fractal dimensions of the leakage current for the security, forecast and danger zones are analyzed under four types of degrees of contamination. The mean value and the standard deviation of the fractal dimension in the forecast zone are calculated to characterize the differences. The analysis reveals large differences in the fractal dimension of leakage current under different contamination discharge stages and degrees. The experimental and calculation results suggest that the fractal dimension of a leakage current waveform can be used as a new indicator of the discharge process and contamination degree of insulators. The results provide new methods and valid indicators for forecasting contamination flashovers.

  8. Ship cabin leakage alarm based on ARM SCM

    Science.gov (United States)

    Qu, Liyan

    2018-03-01

    If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.

  9. Distributed public key schemes secure against continual leakage

    DEFF Research Database (Denmark)

    Akavia, Adi; Goldwasser, Shafi; Hazay, Carmit

    2012-01-01

    -secure against continual memory leakage. Our DPKE scheme also implies a secure storage system on leaky devices, where a value s can be secretely stored on devices that continually leak information about their internal state to an external attacker. The devices go through a periodic refresh protocol......In this work we study distributed public key schemes secure against continual memory leakage. The secret key will be shared among two computing devices communicating over a public channel, and the decryption operation will be computed by a simple 2-party protocol between the devices. Similarly...... against continual memory leakage, under the Bilinear Decisional Diffie-Hellman and $2$-linear assumptions. Our schemes have the following properties: 1. Our DPKE and DIBE schemes tolerate leakage at all times, including during refresh. During refresh the tolerated leakage is a (1/2-o (1),1)-fraction...

  10. Vascular Access in Children

    International Nuclear Information System (INIS)

    Krishnamurthy, Ganesh; Keller, Marc S.

    2011-01-01

    Establishment of stable vascular access is one of the essential and most challenging procedures in a pediatric hospital. Many clinical specialties provide vascular service in a pediatric hospital. At the top of the “expert procedural pyramid” is the pediatric interventional radiologist, who is best suited and trained to deliver this service. Growing awareness regarding the safety and high success rate of vascular access using image guidance has led to increased demand from clinicians to provide around-the-clock vascular access service by pediatric interventional radiologists. Hence, the success of a vascular access program, with the pediatric interventional radiologist as the key provider, is challenging, and a coordinated multidisciplinary team effort is essential for success. However, there are few dedicated pediatric interventional radiologists across the globe, and also only a couple of training programs exist for pediatric interventions. This article gives an overview of the technical aspects of pediatric vascular access and provides useful tips for obtaining vascular access in children safely and successfully using image guidance.

  11. Pediatric vascular access

    International Nuclear Information System (INIS)

    Donaldson, James S.

    2006-01-01

    Pediatric interventional radiologists are ideally suited to provide vascular access services to children because of inherent safety advantages and higher success from using image-guided techniques. The performance of vascular access procedures has become routine at many adult interventional radiology practices, but this service is not as widely developed at pediatric institutions. Although interventional radiologists at some children's hospitals offer full-service vascular access, there is little or none at others. Developing and maintaining a pediatric vascular access service is a challenge. Interventionalists skilled in performing such procedures are limited at pediatric institutions, and institutional support from clerical staff, nursing staff, and technologists might not be sufficiently available to fulfill the needs of such a service. There must also be a strong commitment by all members of the team to support such a demanding service. There is a slippery slope of expected services that becomes steeper and steeper as the vascular access service grows. This review is intended primarily as general education for pediatric radiologists learning vascular access techniques. Additionally, the pediatric or adult interventional radiologist seeking to expand services might find helpful tips. The article also provides education for the diagnostic radiologist who routinely interprets radiographs containing vascular access devices. (orig.)

  12. Arginase 1: an unexpected mediator of pulmonary capillary barrier dysfunction in models of acute lung injury

    Directory of Open Access Journals (Sweden)

    Rudolf eLucas

    2013-08-01

    Full Text Available The integrity of epithelial and endothelial barriers in the lower airspaces of the lungs has to be tightly regulated, in order to prevent leakage and to assure efficient gas exchange between the alveoli and capillaries. Both G- and G+ bacterial toxins, such as LPS and pneumolysin, respectively, can be released in high concentrations within the pulmonary compartments upon antibiotic treatment of patients suffering from acute respiratory distress syndrome (ARDS or severe pneumonia. These toxins are able to impair endothelial barrier function, either directly, or indirectly, by induction of pro-inflammatory mediators and neutrophil sequestration. Toxin-induced endothelial hyperpermeability can involve myosin light chain phosphorylation and/or microtubule rearrangement. Endothelial nitric oxide synthase (eNOS was proposed to be a guardian of basal barrier function, since eNOS knock-out mice display an impaired expression of inter-endothelial junction proteins and as such an increased vascular permeability, as compared to wild type mice. The enzyme arginase, the activity of which can be regulated by the redox status of the cell, exists in two isoforms - arginase 1 (cytosolic and arginase 2 (mitochondrial - both of which can be expressed in lung microvascular endothelial cells. Upon activation, arginase competes with eNOS for the substrate L-arginine, as such impairing eNOS-dependent NO generation and promoting ROS generation by the enzyme. This mini-review will discuss recent findings regarding the interaction between bacterial toxins and arginase during acute lung injury and will as such address the role of arginase in bacterial toxin-induced pulmonary endothelial barrier dysfunction.

  13. Vascular malformations in pediatrics

    International Nuclear Information System (INIS)

    Reith, W.; Shamdeen, M.G.

    2003-01-01

    Vascular malformations are the cause of nearly all non-traumatic intracranial hemorrhage in children beyond the neonatal stage. Therefore, any child presenting with spontaneous intracranial hemorrhage should be evaluated for child abuse and for vascular malformations. Intracerebral malformations of the cerebral vasculature include vein of Galen malformations, arteriovenous malformation (AVM), cavernomas, dural arteriovenous fistulas, venous anomalies (DVA), and capillary teleangiectasies. Although a few familial vascular malformation have been reported, the majority are sporadic. Clinical symptoms, diagnostic and therapeutic options are discussed. (orig.) [de

  14. Vascular endothelium receptors and transduction mechanisms

    CERN Document Server

    Gillis, C; Ryan, Una; Proceedings of the Advanced Studies Institute on "Vascular Endothelium: Receptors and Transduction Mechanisms"

    1989-01-01

    Beyond their obvious role of a barrier between blood and tissue, vascular endothelial cells are now firmly established as active and essential participants in a host of crucial physiological and pathophysiological functions. Probably the two most important factors responsible for promoting the current knowledge of endothelial functions are 1) observations in the late sixties-early seventies that many non-ventilatory properties of the lung could be attributed to the pulmonary endothelium and 2) the establishment, in the early and mid-seventies of procedures for routine culture of vascular endothelial cells. Many of these endothelial functions require the presence of receptors on the surface of the plasma membrane. There is now evidence for the existence among others of muscarinic, a-and /3-adrenergic, purine, insulin, histamine, bradykinin, lipoprotein, thrombin, paf, fibronectin, vitronectin, interleukin and albumin receptors. For some of these ligands, there is evidence only for the existence of endothelial ...

  15. Systemic vasculitis and the lung.

    Science.gov (United States)

    Talarico, Rosaria; Barsotti, Simone; Elefante, Elena; Baldini, Chiara; Tani, Chiara; Mosca, Marta

    2017-01-01

    The purpose of this review is to provide a critical analysis of the recent literature on this topic, with particular focus on the most relevant studies published over the last year. Many studies are published every year on the diagnosis, pathogenesis and treatment of pulmonary involvement in antineutrophil cytoplasmic antibodies (ANCA)-associated vasculitis (AAV). The main subjects covered by this article are the pathogenesis, diagnosis and clinical aspects of lung involvement in ANCA-associated vasculitis and non-ANCA-associated vasculitis. Lung involvement is a common feature in systemic vasculitis. The lungs are one of the most frequently involved organs in systemic vasculitis. In order to provide an update on the recent advances in the pathogenesis, clinical features and novel treatments of lung involvement in systemic vasculitis, a systematic MedLine search has been performed.Most of the data analyzed have confirmed that lung involvement seems to develop more frequently in patients with myeloperoxidase-ANCA-positive AAV, mainly in those with a diagnosis of microscopic polyangiitis (MPA), compared with patients with proteinase 3 ANCA-positive AAV. Moreover, among non-ANCA-associated vasculitis lung involvement may represent a worrying complication of the disease, mainly when associated with vascular involvement.

  16. Characterization of rat lung ICAM-1

    DEFF Research Database (Denmark)

    Beck-Schimmer, B; Schimmer, R C; Schmal, H

    1998-01-01

    studies, rat pulmonary artery endothelial cells (RPAEC), rat alveolar macrophages and aortic rings were stimulated (as described below) and evaluated for ICAM-1 expression. TREATMENT: RPAEC and macrophages were stimulated with lipopolysaccharide (LPS) and recombinant murine tumour necrosis factor alpha...... peaked at 4 h, while lung ICAM- I protein peaked at 6 h. CONCLUSIONS: Quantitation of ICAM-1 expression in vitro and in vivo suggests that ICAM-1 plays a central role in two lung inflammatory models. Furthermore, lung ICAM-1 upregulation involves at least two cell types: vascular endothelial cells...

  17. Comparison of lung preservation solutions in human lungs using an ex vivo lung perfusion experimental model

    Directory of Open Access Journals (Sweden)

    Israel L. Medeiros

    2012-09-01

    Full Text Available OBJECTIVE: Experimental studies on lung preservation have always been performed using animal models. We present ex vivo lung perfusion as a new model for the study of lung preservation. Using human lungs instead of animal models may bring the results of experimental studies closer to what could be expected in clinical practice. METHOD: Brain-dead donors whose lungs had been declined by transplantation teams were used. The cases were randomized into two groups. In Group 1, Perfadex®was used for pulmonary preservation, and in Group 2, LPDnac, a solution manufactured in Brazil, was used. An ex vivo lung perfusion system was used, and the lungs were ventilated and perfused after 10 hours of cold ischemia. The extent of ischemic-reperfusion injury was measured using functional and histological parameters. RESULTS: After reperfusion, the mean oxygenation capacity was 405.3 mmHg in Group 1 and 406.0 mmHg in Group 2 (p = 0.98. The mean pulmonary vascular resistance values were 697.6 and 378.3 dyn·s·cm-5, respectively (p =0.035. The mean pulmonary compliance was 46.8 cm H20 in Group 1 and 49.3 ml/cm H20 in Group 2 (p =0.816. The mean wet/dry weight ratios were 2.06 and 2.02, respectively (p=0.87. The mean Lung Injury Scores for the biopsy performed after reperfusion were 4.37 and 4.37 in Groups 1 and 2, respectively (p = 1.0, and the apoptotic cell counts were 118.75/mm² and 137.50/mm², respectively (p=0.71. CONCLUSION: The locally produced preservation solution proved to be as good as Perfadex®. The clinical use of LPDnac may reduce costs in our centers. Therefore, it is important to develop new models to study lung preservation.

  18. Lung Cancer

    Science.gov (United States)

    Lung cancer is one of the most common cancers in the world. It is a leading cause of cancer death in men and women in the United States. Cigarette smoking causes most lung cancers. The more cigarettes you smoke per day and ...

  19. Leakage experiences with 1 MW steam generator

    International Nuclear Information System (INIS)

    Kanamori, A.; Kawara, M.; Sano, A.

    1975-01-01

    An 1 MW steam generator was tested from October, 1971 and completed with the first series of experiments by May, 1972 after 3600 hours of operation. During these tests, unextraordinary heat absorption was experienced in the downcomer region, which led to shortage of heat transfer area to attain the rated steam temperature and to one of the reasons of flow instabilities. The steam generator was disassembled to get test pieces for structure as well as material examinations and then it was reassembled to proceed the second series of tests. Before it was done, a modification was provided to insulate the downcomer region by putting a gas space around the downcomer tube. The gas space was provided by a dual tube and spacers were welded on the inner tube and an end plate was welded on upper parts between the two to seal the gap by means of fillet welding. After the modified steam generator was put into operation, water happened to leak into a sodium side two times through these additional welding spots for the gas insulation. This paper presents operating conditions and behaviors of monitors at the time of the leakages, identifications of leaked spots, an evaluation of causes and a treatment or a precaution for them

  20. Radiation leakage from linac electron applicator assembly

    International Nuclear Information System (INIS)

    Keys, R.A.; Purdy, J.A.

    1984-01-01

    The electron beam applicator system currently in use on the linear accelerator is constructed of light-weight fiberglass and aluminum. With an applicator in place on the accelerator, the photon collimator jaws are automatically set several centimeters greater than the electron field size projected at the patient's surface. To ensure that no regions of high dose levels exist outside the useful beam, ionization and film measurements were made to quantitate the amount of leakage radiation through the 10 cm x 10 cm and 25 cm x 25 cm applicators. In most regions, the ionization levels at the patient's surface were below 5% of the central axis dose. In one area for the 25 cm applicator, the percentage ionization was 8.5%, which could be reduced by the addition of a small piece of 1/8 inch thick lead. However, ionization levels on the outside surface of the applicator were found to be considerably higher at certain locations for the 25 cm applicator. Results for 6, 9, 12 and 20 MeV electrons are reported here

  1. Lung Cancer Screening

    Science.gov (United States)

    ... factors increase or decrease the risk of lung cancer. Lung cancer is a disease in which malignant (cancer) ... following PDQ summaries for more information about lung cancer: Lung Cancer Prevention Non-Small Cell Lung Cancer Treatment ...

  2. Uterine Vascular Lesions

    Science.gov (United States)

    Vijayakumar, Abhishek; Srinivas, Amruthashree; Chandrashekar, Babitha Moogali; Vijayakumar, Avinash

    2013-01-01

    Vascular lesions of the uterus are rare; most reported in the literature are arteriovenous malformations (AVMs). Uterine AVMs can be congenital or acquired. In recent years, there has been an increasing number of reports of acquired vascular lesions of the uterus following pregnancy, abortion, cesarean delivery, and curettage. It can be seen from these reports that there is confusion concerning the terminology of uterine vascular lesions. There is also a lack of diagnostic criteria and management guidelines, which has led to an increased number of unnecessary invasive procedures (eg, angiography, uterine artery embolization, hysterectomy for abnormal vaginal bleeding). This article familiarizes readers with various vascular lesions of the uterus and their management. PMID:24340126

  3. Magnetic resonance vascular imaging

    International Nuclear Information System (INIS)

    Axel, L

    1989-01-01

    The basis principles of MRI are reviewed in order to understand how blood flow effects arise in conventional imaging. Then some of the ways these effects have ben used in MRI techniques specifically designed for vascular imaging, are considered. (author)

  4. Leakage pattern of linear accelerator treatment heads from multiple vendors

    International Nuclear Information System (INIS)

    Lonski, P.R.; Taylor, M.L.; Franich, R.D.; Harty, P.; Clements, N.; Kron, T.

    2011-01-01

    Full text: Patient life expectancy post-radiotherapy is becoming longer. Therefore, secondary cancers caused by radiotherapy treatment have more time to develop. Increasing attention is being given to out-of-field dose resulting from scatter and accelerator head leakage. Dose leakage from equivalent positions on Varian600C, Varian21-X, Siemens Primus and Elekta Synergy-II linacs were measured with TLD 1 00 H dosimeter chips and compared. Treatment parameters such as field size and beam energy were altered. Leakage doses are presented as a percentage of the dose to isocentre (5 Gy). Results illustrate significant variations in leakage dose between linac models where no model emits consistently lower amounts of radiation leakage for all treatment parameters. Results are shown below. Leakage through the collimator assembly in different units is varying as a function of location and unit design by more than a factor of 10. Differences are more pronounced in comparing Varian or Elekta models, which are fitted with an additional collimator separate from the MLC leaves, to the Siemens model, which uses MLC leaves as its only secondary collimator. Further measurements are currently being taken at the patient plane with a directional detector system to determine the spatial distribution of high leakage sources.

  5. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  6. Developement of leakage localization technique by using acoustic signal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. H.; Jeon, J. H.; Seo, D. H.; Kim, K. W. [KAIST, Daejeon (Korea, Republic of)

    2010-07-15

    The objective of this research is to develop a leakage monitoring system for pipelines or valves in the secondary water system of a nuclear power plant. The system aims to detect the existence of leakage and to estimate the leak location, especially by utilizing the noise generated from the leak. It is safe, precise real-time alert system compared with the previous monitoring methods and tools such as the visual test and the thermal imaging camera. When there exists leakage in the pipeline or valves of nuclear power plant, the noise due to gas flow is radiated through leak region. That is, the secondary water system with leakage generates different noise from the system without leakage. This motivates us to measure and analyze the noise generated from the secondary water system, so as firstly to detect the existence of leakage, and secondly to estimate the leak location by using the noise source identification technique such as beamforming and acoustic holography. Especially the beamforming method models the signal from the noise source to estimate the location of source. Therefore, it is necessary to model the noise due to leakage which is dependent upon parameters. In the process of leak localization, the reflected wave due to interior walls and the measurement noise should be removed for the precise estimation. Therefore, we attempt to characterize the reflected wave and the measurement noise by modeling the interior sound field, thus to remove them and to localize the leak location with high precision

  7. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  8. Junction leakage measurements with micro four-point probes

    DEFF Research Database (Denmark)

    Lin, Rong; Petersen, Dirch Hjorth; Wang, Fei

    2012-01-01

    We present a new, preparation-free method for measuring the leakage current density on ultra-shallow junctions. The junction leakage is found by making a series of four-point sheet resistance measurements on blanket wafers with variable electrode spacings. The leakage current density is calculated...... using a fit of the measured four-point resistances to an analytical two-sheet model. The validity of the approximation involved in the two-sheet model is verified by a comparison to finite element model calculations....

  9. Theory and Application of Magnetic Flux Leakage Pipeline Detection.

    Science.gov (United States)

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-12-10

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted.

  10. Copper ion as a new leakage tracer.

    Science.gov (United States)

    Modaresi, J; Baharizade, M; Shareghi, A; Ahmadi, M; Daneshkazemi, A

    2013-12-01

    Most failures of root canal treatments are caused by bacteria. Studies showed that the most common cause of endodontic failures were the incomplete obturation of the root canal and the lack of adequate apical seal. Some in-vitro methods are used to estimate sealing quality, generally by measuring microleakage that allows the tracer agent to penetrate the filled canal. Conventional methods of evaluating the seal of endodontically treated teeth are complicated and have some drawbacks. We used copper ion diffusion method to assess the leakage and the results were compared to dye penetration method. The crowns of 21 extracted teeth were cut off at the CEJ level. After preparing the canals, the teeth were placed in tubes containing saline. They were divided randomly into 15 experimental cases; 3 positive and 3 negative controls. Positive controls were filled by single cone without sealer while the experimental and the negative control groups were filled by lateral technique. The coronal portion of gutta was removed and 9mm was left. The external surface of each tooth was coated with nail polish. Two millimeters of apical portion was immersed into 9ml of distilled water and 0.3ml of CuSO4 solution was injected into the coronal portion. After 2 days, copper sulfate was measured by an atomic absorption spectrophotometer. The teeth were then immersed in 2% methylene blue for 24 hours, sectioned and the extent of dye penetration was measured by a stereomicroscope. The maximum and minimum recorded copper ion concentrations for the experimental group were 18.37 and 2.87ppm respectively. The maximum and minimum recorded dye penetrations for the experimental group were 8.5 and 3.5mm respectively. The statistical analysis, adopting paired samples test, showed poor correlation between average recorded results of two methods. Based on our results, there was no significant correlation between the dye penetration and the copper ion diffusion methods.

  11. Lung abscess

    International Nuclear Information System (INIS)

    Ha, H.K.; Kang, M.W.; Park, J.M.; Yang, W.J.; Shinn, K.S.; Bahk, Y.W.

    1993-01-01

    Lung abscess was successfully treated with percutaneous drainage in 5 of 6 patients. Complete abscess resolution occurred in 4 patients, partial resolution in one, and no response in one. The duration of drainage ranged from 7 to 18 days (mean 15.5 days) in successful cases. The failure of drainage in one neurologicall impaired patient was attributed to persistent aspiration. In 2 patients, concurrent pleural empyema was also cured. CT provided the anatomic details necessary for choosing the puncture site and avoiding puncture of the lung parenchyma. Percutaneous catheter drainage is a safe and effective method for treating lung abscess. (orig.)

  12. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  13. Leakage potential through mechanical penetrations in a severe accident environment

    International Nuclear Information System (INIS)

    Koenig, L.N.

    1986-01-01

    This paper reviews the findings of an ongoing program, Integrity of Containment Penetrations Under Severe Accident Loads. The program is concerned with the leakage modes as well as the magnitude of leakage through mechanical penetrations in a containment building subject to a severe accident. Seal and gasket tests are used to evaluate the effect of radiation aging, thermal aging, seal geometry, and seal squeeze on seals and gaskets subjected to a hypothesized severe accident. The effects on leakage of the structural response of equipment hatches, personnel airlocks, and drywell heads subjected to severe accident pressures are studied by experiments and analyses. The data gathered during this program will be used to develop methodologies for predicting leakage

  14. N13 - based reactor coolant pressure boundary leakage system

    International Nuclear Information System (INIS)

    Dissing, E.; Marbaeck, L.; Sandell, S.; Svansson, L.

    1980-05-01

    A system for the monitoring of leakage of coolant from the reactor coolant pressure boundary and auxiliary systems to the reactor containment, based on the detection of the N13 content in the atmosphere, has been tested. N13 is produced from the oxyegen of the reactor water via the recoil photon nuclear process H1 + 016 + He4. The generation of N13 is therefore independent of fuel element leakage and of the corrosion product content in the water. In the US AEC regulatory guide 1.45 has a leakage increase of 4 liter/ min been suggested as the response limit. The experiments carried out in Ringhals indicate, that with the accomplishment of minor improvements in the installation, a 4 liter/min leakage to the containment will give rise to a signal with a random error range of +- 0.25 liter/min, 99.7 % confidence level. (author)

  15. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Moreover, the proposed inverter can also eliminate the well-known double line frequency pulsating power....... The mechanism of leakage current suppression and the closed-loop control of pulsating power decoupling are discussed in the paper in details. A 500 W prototype was also built and tested in the laboratory, and both simulation and experimental results are finally presented to show the excellent performance...

  16. Competitiveness and carbon leakages in industry under asymmetric climate policy

    International Nuclear Information System (INIS)

    Demailly, D.

    2008-02-01

    This research aims at studying how to predict competitiveness loss for an industry submitted to an asymmetric carbon constraint, and carbon leakages, whether high losses and important leakages might be feared, and which policies can be used to mitigate these losses and escapes. The author analyses and comments the content of four articles dealing with: the impact on competitiveness, revenue distribution and economic efficiency of a change in the allocation rules for EU greenhouse gas allowances; the relationship between allocation of CO 2 allowances and competitiveness in the case of the European iron and steel industry; CO 2 abatement, competitiveness and leakage in the European cement industry under EU ETS; and leakage from climate policies and border tax adjustment (lessons from a geographic model of the cement industry). Then, the author combines several approaches to study the cement and steel industries

  17. Fractal modeling of fluidic leakage through metal sealing surfaces

    Science.gov (United States)

    Zhang, Qiang; Chen, Xiaoqian; Huang, Yiyong; Chen, Yong

    2018-04-01

    This paper investigates the fluidic leak rate through metal sealing surfaces by developing fractal models for the contact process and leakage process. An improved model is established to describe the seal-contact interface of two metal rough surface. The contact model divides the deformed regions by classifying the asperities of different characteristic lengths into the elastic, elastic-plastic and plastic regimes. Using the improved contact model, the leakage channel under the contact surface is mathematically modeled based on the fractal theory. The leakage model obtains the leak rate using the fluid transport theory in porous media, considering that the pores-forming percolation channels can be treated as a combination of filled tortuous capillaries. The effects of fractal structure, surface material and gasket size on the contact process and leakage process are analyzed through numerical simulations for sealed ring gaskets.

  18. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... completion of the operation the patients were randomized in two groups with and without a transanal stent. RESULTS: A clinically significant leakage was diagnosed in 25 patients (13%). No significant difference was found 17 of 98 patients with a stent and 8 of 96 without (P = 0.09), or in 9 of 44 ileostomy...... patients with a stent and in 3 of 45 without (P = 0.07). Several leaks over a short time led to an interim analysis after inclusion of 194 of 448 planned patients. The analysis showed no significant protective effect of the stent, and more leakages in the stent group, although not statistically significant...

  19. Prediction of leakage in the fixed mechanical seal

    Directory of Open Access Journals (Sweden)

    Asheichik Anatoly A.

    2017-01-01

    Full Text Available The questions of influence of the shape of contact surfaces on leakages through rubber seals in fixed connection of subassemblies are considered in the article. It is known from practice of operation of seals of various designs that the shape of contact surfaces and consequently also the shape of diagram of stresses in a contact zone considerably influences on value of leaks Linking leakage magnitude and distribution of contact stresses enables, firstly, more precisely calculate the amount of leakage for existing seals, and, secondly, to optimize the shape of the seals in their design in each case. As the result of experimental studies on the introduction of the rubber gasket ring fixed indenters different profiles found that by optimizing the shape of the indenter magnitude of leakage can be reduced by 10 times.

  20. Magnetic leakage shield of septum magnet for SPring-8 synchrotron

    International Nuclear Information System (INIS)

    Abe, Hiroshi; Aoki, Tsuyoshi; Fukami, Kenji

    1997-01-01

    This paper describes magnetic field measurements of the prototype septum magnet and countermeasure for reducing the leakage magnetic fields in the incidence and the extraction parts of the SPring-8 synchrotron. We studied and developed 'leakage magnetic shield' on the basis of the tests data got in these measurements. Consequentially, it succeeded in reducing effects of the leakage field to about 50% by installing the shield board in the magnet main body. Then, it was possible to manufacture the magnet which sufficiently held the effect of the leakage field for the electron and positron beam. In this examination, we confirmed the reproduction with the magnetic field distribution of the magnet measured in the manufacturer. We developed and produced of the septum magnets which were carried out determination of the shapes of the magnetic shielding. (author)

  1. Leakage Testing for Different Adhesive Systems and Composites to ...

    African Journals Online (AJOL)

    2015-11-16

    Nov 16, 2015 ... resin composite, the fifth group – two‑stage SE adhesive applied and cavities filled with ... KEYWORDS: Adhesives, composite, evaluation, leakage ... the glass ionomers. ... systems are realized in one or two clinical step(s).[5].

  2. Lung cancer

    Science.gov (United States)

    ... causing chemicals such as uranium, beryllium, vinyl chloride, nickel chromates, coal products, mustard gas, chloromethyl ethers, gasoline, and diesel exhaust Exposure to radon gas Family history of lung cancer ...

  3. Lung surgery

    Science.gov (United States)

    ... are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also be used. Lung surgery using ... Center-Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, ...

  4. Detecting the leakage source of a reservoir using isotopes.

    Science.gov (United States)

    Yi, Peng; Yang, Jing; Wang, Yongdong; Mugwanezal, Vincent de Paul; Chen, Li; Aldahan, Ala

    2018-07-01

    A good monitoring method is vital for understanding the sources of a water reservoir leakage and planning for effective restoring. Here we present a combination of several tracers ( 222 Rn, oxygen and hydrogen isotopes, anions and temperature) for identification of water leakage sources in the Pushihe pumped storage power station which is in the Liaoning province, China. The results show an average 222 Rn activity of 6843 Bq/m 3 in the leakage water, 3034 Bq/m 3 in the reservoir water, and 41,759 Bq/m 3 in the groundwater. Considering that 222 Rn activity in surface water is typically less than 5000 Bq/m 3 , the low level average 222 Rn activity in the leakage water suggests the reservoir water as the main source of water. Results of the oxygen and hydrogen isotopes show comparable ranges and values in the reservoir and the leakage water samples. However, important contribution of the groundwater (up to 36%) was present in some samples from the bottom and upper parts of the underground powerhouse, while the leakage water from some other parts indicate the reservoir water as the dominant source. The isotopic finding suggests that the reservoir water is the main source of the leakage water which is confirmed by the analysis of anions (nitrate, sulfate, and chloride) in the water samples. The combination of these tracer methods for studying dam water leakage improves the accuracy of identifying the source of leaks and provide a scientific reference for engineering solutions to ensure the dam safety. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Method of detecting leakage in nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Koba, Akitoshi; Goto, Seiichiro.

    1974-01-01

    Object: To permit accurate and prompt detection of leakage of a radioactive substance. Structure: The rate of change of such factors as radiation dose, temperature and pressure in the containment vessel, and each detected rate of change is compared with a reference value. The running cycle of the condensed drain exhausting pump in a drain collecting tank within a predetermined period is detected, and it is also compared with a reference value. These comparisons determine the absence or presence of leakage. (Kamimura, M.)

  6. LMFBR technology. FFTF cover-gas leakage calculation

    International Nuclear Information System (INIS)

    Deboi, H.

    1974-01-01

    The FFTF LMFBR is intended to have a near zero release of radioactive gases during normal reactor operation with 1% failed fuel. This report presents calculations which provide an approximation of these cover gas leakages. Data from ongoing static and dynamic seal leak tests at AI are utilized. Leakage through both elastomeric and metallic seals in all sub-assemblies and penetrations comprising the reactor cover gas containment during reactor operation system are included

  7. An alternative treatment for anastomotic leakage after oesophageal resection

    DEFF Research Database (Denmark)

    Damm, P; Hoffmann, J.

    1988-01-01

    An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity.......An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity....

  8. Clinical experience of intrapleural administration of fibrin glue for secondary pneumothorax with advanced lung cancer

    International Nuclear Information System (INIS)

    Nishino, Takeshi; Takizawa, Hiromitsu; Yoshida, Mitsuteru; Kawakami, Yukikiyo; Sakiyama, Shoji; Kondo, Kazuya

    2014-01-01

    Secondary pneumothorax with advanced lung cancer is an intractable and serious pathosis, which directly aggravates patients' Quality of Life (QOL) and prognosis. We first select the intrapleural administration of fibrin glue for secondary pneumothorax with advanced lung cancer. From April 2009 to May 2012, we encountered 5 patients who developed secondary pneumothorax during treatment for advanced lung cancer. Their average age was 60.8 years old, and 4 of them had squamous cell carcinoma, 1 had adenocarcinoma, and all had unresectable advanced lung cancer. In 4 of them, the point of air leakage could be detected by pleurography, and leakage could be stopped by the intrapleural administration of fibrin glue. All of them could receive chemotherapy or radiotherapy after treatment for secondary pneumothorax. The intrapleural administration of fibrin glue may be an effective and valid treatment for intractable secondary pneumothorax with advanced lung cancer. (author)

  9. Unexpandable lung.

    Science.gov (United States)

    Pereyra, Marco F; Ferreiro, Lucía; Valdés, Luis

    2013-02-01

    Unexpandable lung is a mechanical complication by which the lung does not expand to the chest wall, impeding a normal apposition between the two pleural layers. The main mechanism involved is the restriction of the visceral pleura due to the formation of a fibrous layer along this pleural membrane. This happens because of the presence of an active pleural disease (lung entrapment), which can be resolved if proper therapeutic measures are taken, or a remote disease (trapped lung), in which an irreversible fibrous pleural layer has been formed. The clinical suspicion arises with the presence of post-thoracocentesis hydropneumothorax or a pleural effusion that cannot be drained due to the appearance of thoracic pain. The diagnosis is based on the analysis of the pleural liquid, the determination of pleural pressures as we drain the effusion and on air-contrast chest CT. As both represent the continuity of one same process, the results will depend on the time at which these procedures are done. If, when given a lung that is becoming entrapped, the necessary therapeutic measures are not taken, the final result will be a trapped lung. In this instance, most patients are asymptomatic or have mild exertional dyspnea and therefore they do not require treatment. Nevertheless, in cases of incapacitating dyspnea, it may be necessary to use pleural decortication in order to resolve the symptoms. Copyright © 2012 SEPAR. Published by Elsevier Espana. All rights reserved.

  10. Management and prevention of chylous leakage after laparoscopic lymphadenectomy.

    Science.gov (United States)

    Han, L-P; Zhang, H-M; Abha, H-D; Liu, T; Zhang, X-P

    2014-01-01

    To investigate the development and management of chylous leakage after laparoscopic retroperitoneal lymphadenectomy. From July 2006 to September 2013, 13 cases of chylous leakage after the laparoscopic lymphadenectomy (6 cases of renal cell carcinoma, 4 cases of gastric cancer, 2 cases of ovarian cancer, 1 case of endometrial cancer) were studied to analyze the occurrence, development and management of chylous leakage. In 3 cases (2 cases of renal cell carcinoma, 1 case of gastric cancer) massive amount of milky fluid drainage was be seen after the first two days post operation. Dietary intervention, TPN (total parenteral nutrition), somatostatin therapy, maintenance of continuous drainage helped to successfully manage the condition in about 1 month duration. In the remaining 10 cases, chylous leakage appeared after restoring normal diet. Managed with changes in diet and maintenance of unobstructed drainage, they were cured in about 2 weeks after treatment. There was significant reduction in drain output, ultrasonography did not reveal presence of free fluid collection in abdomen, and the patients were in good condition without signs and symptoms of infections. Chylous leakage is a rare complication of retroperitoneal lymph node dissection. Surgeons should be familiar with laparoscopic techniques, relevant anatomy and be aware of the fact that the effect of CO2 pressure and use of ultrasonic knife to occlude the lymphatic vessel can transiently block the leakage making the surgeon overlook them. Routine placement of indwelling drainage tube, immediate diagnosis, dietary modification, TPN, somatostatin and drainage are the modalities of conservative management.

  11. Field size dependent mapping of medical linear accelerator radiation leakage

    International Nuclear Information System (INIS)

    Vu Bezin, Jérémi; De Vathaire, Florent; Diallo, Ibrahima; Veres, Attila; Lefkopoulos, Dimitri; Chavaudra, Jean; Deutsch, Eric

    2015-01-01

    The purpose of this study was to investigate the suitability of a graphics library based model for the assessment of linear accelerator radiation leakage. Transmission through the shielding elements was evaluated using the build-up factor corrected exponential attenuation law and the contribution from the electron guide was estimated using the approximation of a linear isotropic radioactive source. Model parameters were estimated by a fitting series of thermoluminescent dosimeter leakage measurements, achieved up to 100 cm from the beam central axis along three directions. The distribution of leakage data at the patient plane reflected the architecture of the shielding elements. Thus, the maximum leakage dose was found under the collimator when only one jaw shielded the primary beam and was about 0.08% of the dose at isocentre. Overall, we observe that the main contributor to leakage dose according to our model was the electron beam guide. Concerning the discrepancies between the measurements used to calibrate the model and the calculations from the model, the average difference was about 7%. Finally, graphics library modelling is a readily and suitable way to estimate leakage dose distribution on a personal computer. Such data could be useful for dosimetric evaluations in late effect studies. (paper)

  12. International Market Leakage from China’s Forestry Policies

    Directory of Open Access Journals (Sweden)

    Xin Hu

    2014-11-01

    Full Text Available Carbon leakage can be a problem when seeking to reduce carbon emissions through forest policy. International market leakage is mainly caused by supply and demand imbalances in the timber market. This paper selects China, which is implementing forestry policy changes, as the research object. We begin by offering a brief analysis of China’s forestry policy changes, such as the logging quota and Six Key Forestry Programs to determine whether those policies affect timber supply. Second, through the use of three shock variables, carbon leakage is simulated under different scenarios by the Global Trade Analysis Project (GTAP model. The results reveal that the magnitude of leakage caused by implementing China’s forestry policies is between 79.7% and 88.8% with carbon leakage mainly displaced to Russia, Southeast Asia, and the EU. Two effective scenarios for reducing market leakage are presented: forest tenure reform and fast growing forest projects to improve domestic timber production, and raising tariffs on timber imports to reduce imports.

  13. Precision cut lung slices as an efficient tool for in vitro lung physio-pharmacotoxicology studies.

    Science.gov (United States)

    Morin, Jean-Paul; Baste, Jean-Marc; Gay, Arnaud; Crochemore, Clément; Corbière, Cécile; Monteil, Christelle

    2013-01-01

    1.We review the specific approaches for lung tissue slices preparation and incubation systems and the research application fields in which lung slices proved to be a very efficient alternative to animal experimentation for biomechanical, physiological, pharmacological and toxicological approaches. 2.Focus is made on air-liquid interface dynamic organ culture systems that allow direct tissue exposure to complex aerosol and that best mimic in vivo lung tissue physiology. 3.A compilation of research applications in the fields of vascular and airway reactivity, mucociliary transport, polyamine transport, xenobiotic biotransformation, chemicals toxicology and complex aerosols supports the concept that precision cut lung slices are a very efficient tool maintaining highly differentiated functions similar to in vivo lung organ when kept under dynamic organ culture. They also have been successfully used for lung gene transfer efficiency assessment, for lung viral infection efficiency assessment, for studies of tissue preservation media and tissue post-conditioning to optimize lung tissue viability before grafting. 4.Taken all together, the reviewed studies point to a great interest for precision cut lung slices as an efficient and valuable alternative to in vivo lung organ experimentation.

  14. Overview of vascular disease

    International Nuclear Information System (INIS)

    Bisset, G.S. III

    1998-01-01

    Vascular disease in the pediatric population is a poorly understood process which is often underestimated in its incidence. The common beginnings of such ubiquitous diseases as atherosclerosis manifest themselves at a cellular level shortly after birth. Other common systemic disorders, including congestive heart failure and sepsis, are also intricately associated with dysfunctional vasculature. Progress in the understanding of normal and pathophysiologic processes within the vascular system begins with the 'control center' - the endothelial cell. The purpose of this review is to consolidate a body of knowledge on the processes that occur at the cellular level within the blood vessel wall, and to simplify the understanding of how imbalances in these physiologic parameters result in vascular disease. (orig.)

  15. Leakage localization with an acoustic array that covers a wide area for pipeline leakage monitoring in a closed space

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Su [Center for Safety Measurements, Division of Metrology for Quality of Life, Korea Research institute of Standards and Science, Daejeon (Korea, Republic of); Jeon, Jong Hoon [Hyundai Heavy Industry Co.,Ltd., Ulsan (Korea, Republic of); Park, Jin Ho [Korea Atomiv Energy Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is of great importance to localize leakages in complex pipelines for assuring their safety. A sensor array that can detect where leakages occur enables us to monitor a wide area with a relatively low cost. Beam forming is a fast and efficient algorithm to estimate where sources are, but it is generally made use of in free field condition. In practice, however, many pipelines are placed in a closed space for the purpose of safety and maintenance. This leads us to take reflected waves into account to the beam forming for interior leakage localization. Beam power distribution of reflected waves in a closed space is formulated, and spatial average is introduced to suppress the effect of reflected waves. Computer simulations and experiments ensure how the proposed method is effective to localize leakage in a closed space for structural health monitoring.

  16. Comparison of lung protective ventilation strategies in a rabbit model of acute lung injury.

    Science.gov (United States)

    Rotta, A T; Gunnarsson, B; Fuhrman, B P; Hernan, L J; Steinhorn, D M

    2001-11-01

    To determine the impact of different protective and nonprotective mechanical ventilation strategies on the degree of pulmonary inflammation, oxidative damage, and hemodynamic stability in a saline lavage model of acute lung injury. A prospective, randomized, controlled, in vivo animal laboratory study. Animal research facility of a health sciences university. Forty-six New Zealand White rabbits. Mature rabbits were instrumented with a tracheostomy and vascular catheters. Lavage-injured rabbits were randomized to receive conventional ventilation with either a) low peak end-expiratory pressure (PEEP; tidal volume of 10 mL/kg, PEEP of 2 cm H2O); b) high PEEP (tidal volume of 10 mL/kg, PEEP of 10 cm H2O); c) low tidal volume with PEEP above Pflex (open lung strategy, tidal volume of 6 mL/kg, PEEP set 2 cm H2O > Pflex); or d) high-frequency oscillatory ventilation. Animals were ventilated for 4 hrs. Lung lavage fluid and tissue samples were obtained immediately after animals were killed. Lung lavage fluid was assayed for measurements of total protein, elastase activity, tumor necrosis factor-alpha, and malondialdehyde. Lung tissue homogenates were assayed for measurements of myeloperoxidase activity and malondialdehyde. The need for inotropic support was recorded. Animals that received a lung protective strategy (open lung or high-frequency oscillatory ventilation) exhibited more favorable oxygenation and lung mechanics compared with the low PEEP and high PEEP groups. Animals ventilated by a lung protective strategy also showed attenuation of inflammation (reduced tracheal fluid protein, tracheal fluid elastase, tracheal fluid tumor necrosis factor-alpha, and pulmonary leukostasis). Animals treated with high-frequency oscillatory ventilation had attenuated oxidative injury to the lung and greater hemodynamic stability compared with the other experimental groups. Both lung protective strategies were associated with improved oxygenation, attenuated inflammation, and

  17. [Bile leakage after liver resection: A retrospective cohort study].

    Science.gov (United States)

    Menclová, K; Bělina, F; Pudil, J; Langer, D; Ryska, M

    2015-12-01

    Many previous reports have focused on bile leakage after liver resection. Despite the improvements in surgical techniques and perioperative care the incidence of this complication rather keeps increasing. A number of predictive factors have been analyzed. There is still no consensus regarding their influence on the formation of bile leakage. The objective of our analysis was to evaluate the incidence of bile leakage, its impact on mortality and duration of hospitalization at our department. At the same time, we conducted an analysis of known predictive factors. The authors present a retrospective review of the set of 146 patients who underwent liver resection at the Department of Surgery of the 2nd Faculty of Medicine of the Charles University and Central Military Hospital Prague, performed between 20102013. We used the current ISGLS (International Study Group of Liver Surgery) classification to evaluate the bile leakage. The severity of this complication was determined according to the Clavien-Dindo classification system. Statistical significance of the predictive factors was determined using Fishers exact test and Students t-test. The incidence of bile leakage was 21%. According to ISGLS classification the A, B, and C rates were 6.5%, 61.2%, and 32.3%, respectively. The severity of bile leakage according to the Clavien-Dindo classification system - I-II, IIIa, IIIb, IV and V rates were 19.3%, 42%, 9.7%, 9.7%, and 19.3%, respectively. We determined the following predictive factors as statistically significant: surgery for malignancy (pBile leakage significantly prolonged hospitalization time (pbile leakage the perioperative mortality was 23 times higher (pBile leakage is one of the most serious complications of liver surgery. Most of the risk factors are not easily controllable and there is no clear consensus on their influence. Intraoperative leak tests could probably reduce the incidence of bile leakage. In the future, further studies will be required to improve

  18. Excessive leakage measurement using pressure decay method in containment building local leakage rate test at nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Kyu; Kim, Chang Soo; Kim, Wang Bae [KHNP, Central Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

  19. Carbon monoxide inhalation increases microparticles causing vascular and CNS dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jiajun; Yang, Ming [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Kosterin, Paul [Department of Neuroscience, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Salzberg, Brian M. [Department of Physiology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Milovanova, Tatyana N.; Bhopale, Veena M. [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Thom, Stephen R., E-mail: sthom@smail.umaryland.edu [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States)

    2013-12-01

    We hypothesized that circulating microparticles (MPs) play a role in pro-inflammatory effects associated with carbon monoxide (CO) inhalation. Mice exposed for 1 h to 100 ppm CO or more exhibit increases in circulating MPs derived from a variety of vascular cells as well as neutrophil activation. Tissue injury was quantified as 2000 kDa dextran leakage from vessels and as neutrophil sequestration in the brain and skeletal muscle; and central nervous system nerve dysfunction was documented as broadening of the neurohypophysial action potential (AP). Indices of injury occurred following exposures to 1000 ppm for 1 h or to 1000 ppm for 40 min followed by 3000 ppm for 20 min. MPs were implicated in causing injuries because infusing the surfactant MP lytic agent, polyethylene glycol telomere B (PEGtB) abrogated elevations in MPs, vascular leak, neutrophil sequestration and AP prolongation. These manifestations of tissue injury also did not occur in mice lacking myeloperoxidase. Vascular leakage and AP prolongation were produced in naïve mice infused with MPs that had been obtained from CO poisoned mice, but this did not occur with MPs obtained from control mice. We conclude that CO poisoning triggers elevations of MPs that activate neutrophils which subsequently cause tissue injuries. - Highlights: • Circulating microparticles (MPs) increase in mice exposed to 100 ppm CO or more. • MPs are lysed by infusing the surfactant polyethylene glycol telomere B. • CO-induced MPs cause neutrophil activation, vascular leak and CNS dysfunction. • Similar tissue injuries do not arise with MPs obtained from air-exposed, control mice.

  20. Lung function

    International Nuclear Information System (INIS)

    Sorichter, S.

    2009-01-01

    The term lung function is often restricted to the assessment of volume time curves measured at the mouth. Spirometry includes the assessment of lung volumes which can be mobilised with the corresponding flow-volume curves. In addition, lung volumes that can not be mobilised, such as the residual volume, or only partially as FRC and TLC can be measured by body plethysmography combined with the determination of the airway resistance. Body plethysmography allows the correct positioning of forced breathing manoeuvres on the volume-axis, e.g. before and after pharmacotherapy. Adding the CO single breath transfer factor (T LCO ), which includes the measurement of the ventilated lung volume using He, enables a clear diagnosis of different obstructive, restrictive or mixed ventilatory defects with and without trapped air. Tests of reversibility and provocation, as well as the assessment of inspiratory mouth pressures (PI max , P 0.1 ) help to classify the underlying disorder and to clarify treatment strategies. For further information and to complete the diagnostic of disturbances of the ventilation, diffusion and/or perfusion (capillar-)arterial bloodgases at rest and under physical strain sometimes amended by ergospirometry are recommended. Ideally, lung function measurements are amended by radiological and nuclear medicine techniques. (orig.) [de

  1. Regulatory effects of intrinsic IL-10 in IgG immune complex-induced lung injury

    DEFF Research Database (Denmark)

    Shanley, T P; Schmal, H; Friedl, H P

    1995-01-01

    IL-10 has regulatory effects in vitro on cytokine production by activated macrophages. In the IgG immune complex model of lung injury, exogenously administered IL-10 has been shown to suppress in vivo formation of TNF-alpha, up-regulation of vascular ICAM-1, neutrophil recruitment, and ensuing lung....... Blocking of IL-10 by Ab resulted in a 52% increase in lung vascular permeability, a 56% increase in TNF-alpha activity in bronchoalveolar lavage fluids, and a 47 to 48% increase in bronchoalveolar lavage neutrophils and lung myeloperoxidase content. These findings suggest that IL-10 is an important natural...

  2. Renal posttransplant's vascular complications

    Directory of Open Access Journals (Sweden)

    Bašić Dragoslav

    2003-01-01

    Full Text Available INTRODUCTION Despite high graft and recipient survival figures worldwide today, a variety of technical complications can threaten the transplant in the postoperative period. Vascular complications are commonly related to technical problems in establishing vascular continuity or to damage that occurs during donor nephrectomy or preservation [13]. AIM The aim of the presenting study is to evaluate counts and rates of vascular complications after renal transplantation and to compare the outcome by donor type. MATERIAL AND METHODS A total of 463 kidneys (319 from living related donor LD and 144 from cadaveric donor - CD were transplanted during the period between June 1975 and December 1998 at the Urology & Nephrology Institute of Clinical Centre of Serbia in Belgrade. Average recipients' age was 33.7 years (15-54 in LD group and 39.8 (19-62 in CD group. Retrospectively, we analyzed medical records of all recipients. Statistical analysis is estimated using Hi-squared test and Fischer's test of exact probability. RESULTS Major vascular complications including vascular anastomosis thrombosis, internal iliac artery stenosis, internal iliac artery rupture obliterant vasculitis and external iliac vein rupture were analyzed. In 25 recipients (5.4% some of major vascular complications were detected. Among these cases, 22 of them were from CD group vs. three from LD group. Relative rate of these complications was higher in CD group vs. LD group (p<0.0001. Among these complications dominant one was vascular anastomosis thrombosis which occurred in 18 recipients (17 from CD vs. one from LD. Of these recipients 16 from CD lost the graft, while the rest of two (one from each group had lethal outcome. DISCUSSION Thrombosis of renal allograft vascular anastomosis site is the most severe complication following renal transplantation. In the literature, renal allograft thrombosis is reported with different incidence rates, from 0.5-4% [14, 15, 16]. Data from the

  3. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  4. Lung Cancer: Glossary

    Science.gov (United States)

    ... professional support team today. Learn More . Find more lung cancer resources. Learn More Donate Today! What is Lung ... to Give How Your Support Helps Events Lung Cancer Awareness © Lung Cancer Alliance. The information presented in this website ...

  5. Lung Cancer Prevention

    Science.gov (United States)

    ... Colorectal Cancer Kidney (Renal Cell) Cancer Leukemia Liver Cancer Lung Cancer Lymphoma Pancreatic Cancer Prostate Cancer Skin Cancer ... following PDQ summaries for more information about lung cancer: Lung Cancer Screening Non-Small Cell Lung Cancer Treatment ...

  6. Lung cancer - small cell

    Science.gov (United States)

    Cancer - lung - small cell; Small cell lung cancer; SCLC ... About 15% of all lung cancer cases are SCLC. Small cell lung cancer is slightly more common in men than women. Almost all cases of SCLC are ...

  7. [Lung scintigraphy].

    Science.gov (United States)

    Schümichen, Carl; Schmidt, Matthias; Krause, Thomas

    2018-06-01

    The S1 guideline for lung scintigraphy has been updated and extended in order to emphasize the advantages oft the method in detecting acute pulmonary embolism (PE) in the periphery oft the lung (subsegmental PE), in underlying subacute and chronic pulmonary disorders, as well as in detecting chronic LE (CTEPH). Method of choice is ventilation / perfusion (V/P) SPECT or V/P SPECT/CT with even higher specificity. Because of its high sensitivity, a threshold (V/P mismatch in at least one segment or two subsegments) is introduced to avoid overtreatment. In case of a change in the therapeutic approach (observation only instead of anticoaculation) the threshold can be omitted. New data concerning the clinical and therapeutical impact of subsegmental PE are included, the chapters open questions have been extented. Other indications for V/P SPECT (secondary diagnoses, abnormalities in pulmonary perfusion, prediction of postoperative lung function) are presented with new data. Schattauer GmbH.

  8. Leakage evaluation in the PCV (Primary Containment Vessel) using chemical and radiochemical data

    International Nuclear Information System (INIS)

    Maeda, Katsuji; Nagasawa, Katsumi

    1998-01-01

    Keeping the reliability of nuclear power plant operation, the primary coolant leakage in the PCV is strictly restricted by the Technical Specifications. It is very important to detect an indication of leakage and estimate the source of leakage to provide countermeasures. Usually the indication of leakage will be detected by increase of drain flow in the PCV sump. There are some possibilities of leakage sources in the PCV, such as reactor water, main steam, condensate, feedwater and closed cooling water. The leakage source contain different chemical and radiochemical species. This means that the leakage source can be presumed and detected by using chemical information from the PCV atmosphere and sump water. To detect the leakage indication and the source quickly and exactly, the PCV Leakage Detection Expert System has been developed. This paper describes how to evaluate the leakage indication and source in the PCV by using chemical and radiochemical data. (author)

  9. Obesity-Induced Endoplasmic Reticulum Stress Causes Lung Endothelial Dysfunction and Promotes Acute Lung Injury.

    Science.gov (United States)

    Shah, Dilip; Romero, Freddy; Guo, Zhi; Sun, Jianxin; Li, Jonathan; Kallen, Caleb B; Naik, Ulhas P; Summer, Ross

    2017-08-01

    Obesity is a significant risk factor for acute respiratory distress syndrome. The mechanisms underlying this association are unknown. We recently showed that diet-induced obese mice exhibit pulmonary vascular endothelial dysfunction, which is associated with enhanced susceptibility to LPS-induced acute lung injury. Here, we demonstrate that lung endothelial dysfunction in diet-induced obese mice coincides with increased endoplasmic reticulum (ER) stress. Specifically, we observed enhanced expression of the major sensors of misfolded proteins, including protein kinase R-like ER kinase, inositol-requiring enzyme α, and activating transcription factor 6, in whole lung and in primary lung endothelial cells isolated from diet-induced obese mice. Furthermore, we found that primary lung endothelial cells exposed to serum from obese mice, or to saturated fatty acids that mimic obese serum, resulted in enhanced expression of markers of ER stress and the induction of other biological responses that typify the lung endothelium of diet-induced obese mice, including an increase in expression of endothelial adhesion molecules and a decrease in expression of endothelial cell-cell junctional proteins. Similar changes were observed in lung endothelial cells and in whole-lung tissue after exposure to tunicamycin, a compound that causes ER stress by blocking N-linked glycosylation, indicating that ER stress causes endothelial dysfunction in the lung. Treatment with 4-phenylbutyric acid, a chemical protein chaperone that reduces ER stress, restored vascular endothelial cell expression of adhesion molecules and protected against LPS-induced acute lung injury in diet-induced obese mice. Our work indicates that fatty acids in obese serum induce ER stress in the pulmonary endothelium, leading to pulmonary endothelial cell dysfunction. Our work suggests that reducing protein load in the ER of pulmonary endothelial cells might protect against acute respiratory distress syndrome in obese

  10. Lung radiopharmaceuticals

    International Nuclear Information System (INIS)

    Gonzalez, B.M.

    1994-01-01

    Indication or main clinical use of Lung radiopharmaceuticals is presented and clasification of radiopharmaceuticals as ventilation and perfusion studies. Perfusion radiopharmaceuticals, main controls for administration quality acceptance. Clearence after blood administration and main clinical applications. Ventilation radiopharmaceuticals, gases and aerosols, characteristics of a ideal radioaerosol, techniques of good inhalation procedure, clinical applications. Comparison of several radiopharmaceuticals reflering to retention time as 50% administered dose, percent administered dose at 6 hours post inhalation, blood activity at 30 and 60 minutes post inhalation, initial lung absorbed dose, cumulated activity.Kinetic description of two radiopharmaceuticals, 99mTcDTPA and 99mTc-PYP

  11. Suppression and control of leakage field in electromagnetic helical microwiggler

    Energy Technology Data Exchange (ETDEWEB)

    Ohigashi, N. [Kansai Univ., Osaka (Japan); Tsunawaki, Y. [Osaka Sangyo Univ. (Japan); Imasaki, K. [Institute for Laser Technology, Osaka (Japan)] [and others

    1995-12-31

    Shortening the period of electromagnetic wiggler introduces both the radical increase of the leakage field and the decrease of the field in the gap region. The leakage field is severer problem in planar electromagnetic wiggler than in helical wiggler. Hence, in order to develop a short period electromagnetic wiggler, we have adopted {open_quotes}three poles per period{close_quotes} type electromagnetic helical microwiggler. In this work, we inserted the permanent magnet (PM) blocks with specific magnetized directions in the space between magnetic poles, for suppressing the leakage field flowing out from a pole face to the neighboring pole face. These PM-blocks must have higher intrinsic coersive force than saturation field of pole material. The gap field due to each pole is adjustable by controlling the leakage fields, that is, controlling the position of each iron screw set in each retainer fixing the PM-blocks. At present time, a test wiggler with period 7.8mm, periodical number 10 and gap length 4.6mm has been manufactured. Because the ratio of PM-block aperture to gap length is important parameter to suppress the leakage field, the parameter has been surveyed experimentally for PM-blocks with several dimensions of aperture. The field strength of 3-5kG (K=0.2-0.4) would be expected in the wiggler.

  12. Report on the water leakage from instrumentation pipe in JMTR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    On December 10, 2002, the leakage was found at the pressure instrumentation pipe attached to the exit pipe of No.1 charging pump of the purification system of a primary cooling system at JMTR in the Oarai Research establishment, JAERI. The Investigation Committee for Water Leakage from Instrumentation Pipe in JMTR was established and organized by specialists from inside and outside JAERI on December 16 and its meeting was held in public 3 times by 6th January, 2003. They found out the cause and countermeasures of cracks, and also investigated enhancement of safety management. As the result, it was considered that the leakage started around the 6th of December 2002 and the cause of the cracks was due to fatigue by vibration of the charging pump during operation. The committee discovered following incorrect actions in the safety management. First, operation of JMTR was continued without keeping careful watch in spite of occurrence of leakage detector alarm. Second, every time when the alarm range for the reasons other than the leakage, appropriate investigation and countermeasure were not taken. Third, the manager in charge didn't have a fair understanding of the situation and didn't give an appropriate direction. This is the report on the cause and countermeasures of cracks and enhancement of safety management. (author)

  13. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS AND METH....... On this basis it was decided to discontinue the study prematurely for ethical reasons. CONCLUSION: Decompression of the anastomosis with a transanal stent does not reduce the risk of anastomotic leakage after anterior resection.......OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... AND METHODS: Randomized open trial of 194 patients operated in 11 hospitals during September 2000 to September 2003 with anterior resection for a mobile rectal tumour, 115 men and 79 women, median age 68 years (range 37-90 years). The surgeon decided upon the use of a protective ileostomy, and after...

  14. New Method for Leakage Detection by Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Mohammad Attari

    2018-03-01

    Full Text Available Nowadays water loss has been turned into a global concern and on the other hand the demand for water is increasing. This problem has made the demand management and consumption pattern reform necessary. One of the most important methods for managing water consumption is to decrease the water loss. In this study by using neural networks, a new method is presented to specify the location and quantity of leakages in water distribution networks.  In this method, by producing the training data and applying it to neural network, the network is able to determine approximate location and quantity of nodal leakage with receiving the nodal pressure. Production of training data is carried out by applying assumed leakage to specific nodes in the network and calculating the new nodal pressures. The results show that by minimum use of hydraulic data taken from pressures, not only this method can determine the location of nodal leakages, but also it can specify the amount of leakage on each node with reasonable accuracy.

  15. Gas-path leakage seal for a gas turbine

    Science.gov (United States)

    Wolfe, C.E.; Dinc, O.S.; Bagepalli, B.S.; Correia, V.H.; Aksit, M.F.

    1996-04-23

    A gas-path leakage seal is described for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a gas turbine (such as combustor casing segments). The seal includes a generally imperforate foil-layer assemblage which is generally impervious to gas and is located in the leakage-gap. The seal also includes a cloth-layer assemblage generally enclosingly contacting the foil-layer assemblage. In one seal, the first edge of the foil-layer assemblage is left exposed, and the foil-layer assemblage resiliently contacts the first member near the first edge to reduce leakage in the ``plane`` of the cloth-layer assemblage under conditions which include differential thermal growth of the two members. In another seal, such leakage is reduced by having a first weld-bead which permeates the cloth-layer assemblage, is attached to the metal-foil-layer assemblage near the first edge, and unattachedly contacts the first member. 4 figs.

  16. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  17. Risk factors, treatment and impact on outcomes of bile leakage after hemihepatectomy.

    Science.gov (United States)

    Zheng, Si-Ming; Li, Hong; Li, Gen-Cong; Yu, Dan-Song; Ying, Dong-Jian; Zhang, Bin; Lu, Cai-De; Zhou, Xin-Hua

    2017-07-01

    Risk factors for bile leakage after hemihepatectomy are unknown. A prospectively maintained database review identified patients undergoing hemihepatectomy between 1 January 2009 and 30 September 2014. Patients were divided into B/C and non-B/C bile leakage groups. Risk factors for bile leakage were predicted and assessments of their impact on patients were made. Bile leakage occurred in 91 of the 297 patients (30.6%); 64 cases were classified as grade B bile leakage (21.5%) and three cases as grade C bile leakage (1.0%). Multivariate analysis confirmed that elevated preoperative alanine transaminase (ALT), positive bile culture during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery were risk factors for B/C grade bile leakage (P bile leakage (P bile leakage (P bile leakage group were higher than those in the non-B/C bile leakage group (P bile leakage group also required prolonged hospitalization (P 0.05). Patient with elevated preoperative ALT, positive bile cultures during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery are more likely to complicate bile leakage. We should use biliary drainage such as preoperative PTBD, ENBD or intraoperative Kehr's T-tube drainage to reduce and treat bile leakage in patients with high risk of bile leakage. © 2015 Royal Australasian College of Surgeons.

  18. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  19. Evaluation of isolation valve leakage in alternate charging piping

    International Nuclear Information System (INIS)

    Strauch, P.L.; Roarty, D.H.; Brice-Nash, R.L.

    1995-01-01

    The chemical and volume control system (CVCS) alternate charging flow path at an operating pressurized water reactor (PWR) plant was determined to be susceptible to adverse stresses from isolation valve leakage. Isolation valve leakage had resulted in pipe cracks at several nuclear units worldwide, as described in United States Nuclear Regulatory Commission Bulletin 88-08 and its supplements. To provide for continuing assurance that cracks would not initiate over the plant life, the operators considered performing fatigue evaluation to demonstrate structural integrity of the system. This evaluation included heat transfer, stress and fatigue analysis, using methods described in Electric Power Research Institute Report ''Thermal Stratification, Cycling, and Striping (TASCS),'' March 1994. The evaluation concluded that the fatigue usage would be less than 1.0 under worst case isolation valve leakage conditions, and therefore a significant investment in permanent temperature monitoring was avoided

  20. Functions and requirements for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides the initial functions and requirements for the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. A Mission Analysis has been completed, this document reflects the next step in the systems engineering approach to decompose the mission into primary functions and requirements. The functions and requirements in this document apply to mitigative actions to be taken regarding below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage mitigation is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities

  1. Research on leakage detection of nuclear power station primary loop

    International Nuclear Information System (INIS)

    Cao Shengquan; Yang Jicai; Li Jianjun; Dong Zhijuan; Ren Juyan; Zhang Pinyuan

    1993-01-01

    The sensor of leak-detection system is a special humidity-sensitive element. In this system, the collection and treatment of detected data, and the leakage alarm are controlled by a simple board computer. The three parameters A, B and C are set up in this system, and the alarm will give out when signal surpasses values of B and C at the same time. The effects of environment humidity and temperature on collection of detected data are considered, and the leakage alarm is reliable. When the leakage rate of water at 320 degree C and 12.2 MPa is 0.3 g/min, the alarm signal will sent out within 5 s

  2. Leakage of pressurized gases through unlined concrete containment structures

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.

    1983-01-01

    Eight reinforced concrete specimens were fabricated and subjected to tensile membrane forces and air pressure to study the air leakage characteristics in cracked reinforced concrete members. A mathematical expression for the rate of pressurized air flowing through an idealized crack is presented. The mathematical expression is refined by using the experimental data to describe the air flow rate through any given crack pattern. Graphical charts are also presented for the calculation of the air leakage rate through concrete cracks. The concept of equivalent crack width for a given crack pattern is introduced. The mathematical expression and graphical charts are modified to include this equivalent crack width concept. The proposed technique is applicable for the prediction of the leakage from concrete containment structures or any similar structures due to high internal pressure sufficient to initiate cracking. (orig.)

  3. Suppression of tunneling leakage current in junctionless nanowire transistors

    International Nuclear Information System (INIS)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-01-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out. (paper)

  4. Suppression of tunneling leakage current in junctionless nanowire transistors

    Science.gov (United States)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-12-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out.

  5. On the Connection between Leakage Tolerance and Adaptive Security

    DEFF Research Database (Denmark)

    Nielsen, Jesper Buus; Venturi, Daniele; Zottarel, Angela

    2013-01-01

    We revisit the context of leakage-tolerant interactive protocols as defined by Bitanski, Canetti and Halevi (TCC 2012). Our contributions can be summarized as follows: For the purpose of secure message transmission, any encryption protocol with message space M and secret key space SK tolerating...... at the end of the protocol execution, if and only if the protocol has passive adaptive security against an adaptive corruption of one party at the end of the protocol execution. This shows that as soon as a little leakage is tolerated, one needs full adaptive security. In case more than one party can...... be corrupted, we get that leakage tolerance is equivalent to a weaker form of adaptivity, which we call semi-adaptivity. Roughly, a protocol has semi-adaptive security if there exist a simulator which can simulate the internal state of corrupted parties, however, such a state is not required...

  6. Lung Transplant

    Science.gov (United States)

    ... Severity of the recipient's lung disease Recipient's overall health Likelihood that the transplant will be successful Immediately before ... will begin within days of your surgery. Your health care team will likely work with you to design an exercise program that's right for you. Your doctor may ...

  7. Lung cancer

    DEFF Research Database (Denmark)

    Hansen, H H; Rørth, M

    1999-01-01

    The results of the many clinical trials published in 1997 had only modest impact on the treatment results using either cytostatic agents alone or combined with radiotherapy in lung cancer. In SCLC, combination chemotherapy including platin-compounds (cisplatin, carboplatin) and the podophyllotoxins...

  8. Major Vascular Neurocognitive Disorder: A Reappraisal to Vascular Dementia

    Directory of Open Access Journals (Sweden)

    Emre Kumral

    2017-03-01

    Full Text Available Major vascular neurocognitive disorder (NCD is the second leading form of dementia after Alzheimer’s disease, accounting for 17-20% of all dementias. Vascular NCD is a progressive disease caused by reduced cerebral blood flow related to multiple large volume or lacunar infarcts that induce a sudden onset and stepwise decline in cognitive abilities. Despite its prevalence and clinical importance, there is still controversy in the terminology of vascular NCD. Only after the release of Diagnostic and Statistical Manual of Mental Disorders-5 (DSM-5 (2013 did the American Psychiatric Association define vascular dementia as “major vascular NCD”. This review includes an overview of risk factors, pathophysiology, types, diagnostic and clinical features of major vascular NCD, and current treatment options of vascular NCD regarding to DSM-5 criteria

  9. On camera-based smoke and gas leakage detection

    Energy Technology Data Exchange (ETDEWEB)

    Nyboe, Hans Olav

    1999-07-01

    Gas detectors are found in almost every part of industry and in many homes as well. An offshore oil or gas platform may host several hundred gas detectors. The ability of the common point and open path gas detectors to detect leakages depends on their location relative to the location of a gas cloud. This thesis describes the development of a passive volume gas detector, that is, one than will detect a leakage anywhere in the area monitored. After the consideration of several detection techniques it was decided to use an ordinary monochrome camera as sensor. Because a gas leakage may perturb the index of refraction, parts of the background appear to be displaced from their true positions, and it is necessary to develop algorithms that can deal with small differences between images. The thesis develops two such algorithms. Many image regions can be defined and several feature values can be computed for each region. The value of the features depends on the pattern in the image regions. The classes studied in this work are: reference, gas, smoke and human activity. Test show that observation belonging to these classes can be classified fairly high accuracy. The features in the feature set were chosen and developed for this particular application. Basically, the features measure the magnitude of pixel differences, size of detected phenomena and image distortion. Interesting results from many experiments are presented. Most important, the experiments show that apparent motion caused by a gas leakage or heat convection can be detected by means of a monochrome camera. Small leakages of methane can be detected at a range of about four metres. Other gases, such as butane, where the densities differ more from the density of air than the density of methane does, can be detected further from the camera. Gas leakages large enough to cause condensation have been detected at a camera distance of 20 metres. 59 refs., 42 figs., 13 tabs.

  10. The Effect of Internal Leakages on Thermal Performance in NPPs

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Kim, Doo Won; Jang, Seok Bo

    2007-01-01

    Since the Balance Of Plant (BOP, limited to a turbine cycle in this study) does not contain radioactive material, regulatory authorities did not need to have concerns on it. As the interests on safety and performance is getting more serious and extensive, controlling the level of safety and performance of a BOP have just begun or is about to begin. The performance standards or ageing management programs of the major equipment in a BOP is being developed. The regulatory requirements for tests and/or maintenance are being actively built up. There is also a probabilistic approach quantifying performance of a BOP. The study on quantifying the rate of unanticipated shutdowns caused by careless maintenance and/or tests conducted in a BOP is going on. In this study, the modeling of the entire BOP and the methodologies of thermal performance analysis should be one of the must-have items as well. This study was achieved to ensure fundamental skills related to 1) the detailed steady-state modeling of a BOP and 2) thermal performance analysis under various conditions. Particularly, the paper will focus on the effect of internal leakages inside the valves and FeedWater Heaters (FWHs). The internal leakage is regarded as the flow movement through the isolated path but remaining inside the system boundary of a BOP. For instance, the leakage from one side of a valve seat to the other side, or the leakage through the cracked tubes or tube-sheets in a heat exchanger correspond to internal leakages. We made a BOP model of OPR1000 and investigated thermal performance under the internal leakage in Turbine Bypass Condenser Dump Valves (TBCDV) and FWHs

  11. Marginal Leakage of Class V Composite Resin Restorations

    Directory of Open Access Journals (Sweden)

    Maryam Khoroushi

    2018-01-01

    Full Text Available >Introduction: Marginal leakage is one of the significant causes of restoration failure. This in-vitro study was conducted to compare cone beam computed tomography (CBCT and dye-penetration methods for determining marginal leakage at gingival surface of class V resin composite restorations.Materials and Methods: Class V cavities were prepared on the buccal surfaces of nineteen caries-free extracted human molar teeth. Cavities were conditioned and filled. The teeth were immersed in a 50% w/w aqueous silver nitrate solution for 24 h and were taken out and rinsed with distilled water. Then, they were put into a developing solution. Whole specimens were first viewed with CBCT and were then sectioned and evaluated by stereomicroscope.Results: Measurement of agreement between CBCT and stereomicroscope revealed that 15 (78.9% teeth had score 0, 1 (5.3% tooth had score 1, and 1 (5.3% tooth had score 2 in both techniques. Measurement of agreement between CBCT and stereomicroscope techniques, in the detection of marginal leakage, was 89.5% (Kappa coefficient = 0.627, P = 0.00. The Wilcoxon paired rank test revealed no significant difference between the results of CBCT and stereomicroscope in measuring the leakage at gingival margin (P = 0.157.Conclusion: Considering the limitations of the study, there was no significant difference between the results of CBCT and stereomicroscope in measuring the leakage at gingival margin of class V composite restorations. CBCT can be used noninvasively to detect the marginal leakage of gingival wall of class V composite restorations using aqueous silver nitrate solution as a tracer.

  12. Plant Vascular Biology 2010

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Biao

    2014-11-17

    This grant supported the Second International Conference on Plant Vascular Biology (PVB 2010) held July 24-28, 2010 on the campus of Ohio State University, Columbus, Ohio. Biao Ding (Ohio State University; OSU) and David Hannapel (Iowa State University; ISU) served as co-chairs of this conference. Biao Ding served as the local organizer. PVB is defined broadly here to include studies on the biogenesis, structure and function of transport systems in plants, under conditions of normal plant growth and development as well as of plant interactions with pathogens. The transport systems cover broadly the xylem, phloem, plasmodesmata and vascular cell membranes. The PVB concept has emerged in recent years to emphasize the integrative nature of the transport systems and approaches to investigate them.

  13. Vascular cognitive impairment

    Directory of Open Access Journals (Sweden)

    N.V. Vakhnina

    2014-01-01

    Full Text Available Vascular pathology of the brain is the second most common cause of cognitive impairment after Alzheimer's disease. The article describes the modern concepts of etiology, pathogenetic mechanisms, clinical features and approaches to diagnosis and therapy of vascular cognitive impairment (VCI. Cerebrovascular accident, chronic cerebral circulatory insufficiency and their combination, sometimes in combination with a concomitant neurodegenerative process, are shown to be the major types of brain lesions leading to VCI. The clinical presentation of VCI is characterized by the neuropsychological status dominated by impairment of the executive frontal functions (planning, control, attention in combination with focal neurological symptoms. The diagnosis is based on comparing of the revealed neuropsychological and neurological features with neuroimaging data. Neurometabolic, acetylcholinergic, glutamatergic, and other vasoactive drugs and non-pharmacological methods are widely used to treat VCI. 

  14. Vascular Surgery and Robotics

    Directory of Open Access Journals (Sweden)

    Indrani Sen

    2016-01-01

    Full Text Available The application of robotics to Vascular surgery has not progressed as rapidly as of endovascular technology, but this is changing with the amalgamation of these two fields. The advent of Endovascular robotics is an exciting field which overcomes many of the limitations of endovascular therapy like vessel tortuosity and operator fatigue. This has much clinical appeal for the surgeon and hold significant promise of better patient outcomes. As with most newer technological advances, it is still limited by cost and availability. However, this field has seen some rapid progress in the last decade with the technology moving into the clinical realm. This review details the development of robotics, applications, outcomes, advantages, disadvantages and current advances focussing on Vascular and Endovascular robotics

  15. Root cause evaluation of pressurizer relief valve leakage

    International Nuclear Information System (INIS)

    Olson, D.E.; Voll, B.J.

    1996-01-01

    Pressurizer relief valves at two pressurized water reactor units experienced unacceptable leakage during plant heatup. The leakage was suspected to be caused by excessive pipe loads on the valves. This paper describes how monitoring via hard-wired transducers and a digital data acquisition system was used to quantify the pipe loads on the valves, and assist in determining the root cause of the pipe loads and appropriate corrective actions. The selection of the parameters monitored, how the monitoring was accomplished and interpretation of the results is discussed. The corrective actions implemented based on the monitoring results are also discussed

  16. Leakage radiation spectroscopy of organic/dielectric/metal systems

    DEFF Research Database (Denmark)

    Fiutowski, Jacek; Kawalec, Tomasz; Kostiučenko, Oksana

    2014-01-01

    side of a hemisphere fused silica prism with an index matching liquid was illuminated under normal incidence by a He-Cd 325 nm laser. Two orthogonal linear polarizations were used both parallel and perpendicular to the detection plane. Spectrally resolved leakage radiation was observed on the opposite......Leakage radiation spectroscopy of organic para-Hexaphenylene (p-6P) molecules has been performed in the spectral range 420-675 nm which overlaps with the p-6P photoluminescence band. The p-6P was deposited on 40 nm silver (Ag) films on BK7 glass, covered with SiO2 layers. The SiO2 layer thickness...

  17. Method for detecting resin leakage in LWR coolant

    International Nuclear Information System (INIS)

    Girard, J.E.

    1988-05-01

    Resin leakage from condensate polishing units can result in steam generator corrosion. This report describes the development of a resin leakage detection method based in analyzing the organic breakdown products released from resin on heating. The breakdown products are analyzed using high performance liquid chromatography (HPLC) with fluorescence detection. Some of the organic products formed have been identified. A design for a resin monitoring unit, suitable for incorporation into the IONTRAC system, is presented. Theoretically, detection of ppB levels of resin by processing about one liter of water, is possible

  18. Carbon leakage revisited. Unilateral climate policy under directed technical change

    International Nuclear Information System (INIS)

    Maria, Corrado Di; Van derWerf, E.

    2005-01-01

    This paper analyzes the consequences of unilateral climate policy in the presence of directed technical change. We develop a dynamic two-country model in which two otherwise identical countries differ in their environmental policy: one of the countries enforces a (binding) cap on emissions while the other does not. Focusing on carbon leakage, we show how, compared with a 'traditional' endogenous growth model, directed technical change will always lead to lower emissions in the unconstrained country. When clean and dirty goods are good substitutes, it may even be induced to reduce its emissions below the optimum level when both countries are unconstrained, so leakage is negative

  19. Leakage tests of wall segments of reactor containments

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.; MacGregor, J.G.

    1979-10-01

    Two prestressed concrete wall segments simulating portions of containment walls were loaded by axial tensile forces to cause cracking of the concrete. At each load increment air pressure was applied in steps up to 21 psi to one side of the segment and the rate of leakage of air through the cracked concrete section was measured. A theoretical equation for the flow of air through concrete cracks is developed and the results from one leakage test are used to determine the dimensionless constant required for this equation. (author)

  20. Vascular lesions following radiation

    International Nuclear Information System (INIS)

    Fajardo, L.F.; Berthrong, M.

    1988-01-01

    The special radiation sensitivity of the vascular system is mainly linked to that of endothelial cells, which are perhaps the most radiation-vulnerable elements of mesenchymal tissues. Within the vascular tree, radiation injures most often capillaries, sinusoids, and small arteries, in that order. Lesions of veins are observed less often, but in certain tissues the veins are regularly damaged (e.g., intestine) or are the most affected structures (i.e., liver). Large arteries do suffer the least; however, when significant damage does occur in an elastic artery (e.g., thrombosis or rupture), it tends to be clinically significant and even fatal. Although not always demonstrable in human tissues, radiation vasculopathy generally is dose and time dependent. Like other radiation-induced lesions, the morphology in the vessels is not specific, but it is characteristic enough to be often recognizable. Vascular injury, especially by therapeutic radiation is not just a morphologic marker. It is a mediator of tissue damage; perhaps the most consistent pathogenetic mechanism in delayed radiation injury

  1. Vascular lumen formation.

    Science.gov (United States)

    Lammert, Eckhard; Axnick, Jennifer

    2012-04-01

    The vascular system developed early in evolution. It is required in large multicellular organisms for the transport of nutrients, oxygen, and waste products to and from tissues. The vascular system is composed of hollow tubes, which have a high level of complexity in vertebrates. Vasculogenesis describes the de novo formation of blood vessels, e.g., aorta formation in vertebrate embryogenesis. In contrast, angiogenesis is the formation of blood vessels from preexisting ones, e.g., sprouting of intersomitic blood vessels from the aorta. Importantly, the lumen of all blood vessels in vertebrates is lined and formed by endothelial cells. In both vasculogenesis and angiogenesis, lumen formation takes place in a cord of endothelial cells. It involves a complex molecular mechanism composed of endothelial cell repulsion at the cell-cell contacts within the endothelial cell cords, junctional rearrangement, and endothelial cell shape change. As the vascular system also participates in the course of many diseases, such as cancer, stroke, and myocardial infarction, it is important to understand and make use of the molecular mechanisms of blood vessel formation to better understand and manipulate the pathomechanisms involved.

  2. Pulmonary vascular imaging

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Shure, D.

    1987-01-01

    A wide range of pulmonary vascular imaging techniques are available for the diagnostic evaluation of patients with suspected pulmonary vascular disease. The characteristics of any ideal technique would include high sensitivity and specificity, safety, simplicity, and sequential applicability. To date, no single technique meets these ideal characteristics. Conventional pulmonary angiography remains the gold standard for the diagnosis of acute thromboembolic disease despite the introduction of newer techniques such as digital subtraction angiography and magnetic resonance imaging. Improved noninvasive lower extremity venous testing methods, particularly impedance plethysmography, and ventilation-perfusion scanning can play significant roles in the noninvasive diagnosis of acute pulmonary emboli when properly applied. Ventilation-perfusion scanning may also be useful as a screening test to differentiate possible primary pulmonary hypertension from chronic thromboembolic pulmonary hypertension. And, finally, angioscopy may be a useful adjunctive technique to detect chronic thromboembolic disease and determine operability. Optimal clinical decision-making, however, will continue to require the proper interpretation of adjunctive information obtained from the less-invasive techniques, applied with an understanding of the natural history of the various forms of pulmonary vascular disease and with a knowledge of the capabilities and shortcomings of the individual techniques

  3. Vascular alterations in PDAPP mice after anti-Aβ immunotherapy: Implications for amyloid-related imaging abnormalities.

    Science.gov (United States)

    Zago, Wagner; Schroeter, Sally; Guido, Teresa; Khan, Karen; Seubert, Peter; Yednock, Ted; Schenk, Dale; Gregg, Keith M; Games, Dora; Bard, Frédérique; Kinney, Gene G

    2013-10-01

    Clinical studies of β-amyloid (Aβ) immunotherapy in Alzheimer's disease (AD) patients have demonstrated reduction of central Aβ plaque by positron emission tomography (PET) imaging and the appearance of amyloid-related imaging abnormalities (ARIA). To better understand the relationship between ARIA and the pathophysiology of AD, we undertook a series of studies in PDAPP mice evaluating vascular alterations in the context of central Aβ pathology and after anti-Aβ immunotherapy. We analyzed PDAPP mice treated with either 3 mg/kg/week of 3D6, the murine form of bapineuzumab, or isotype control antibodies for periods ranging from 1 to 36 weeks and evaluated the vascular alterations in the context of Aβ pathology and after anti-Aβ immunotherapy. The number of mice in each treatment group ranged from 26 to 39 and a total of 345 animals were analyzed. The central vasculature displayed morphological abnormalities associated with vascular Aβ deposits. Treatment with 3D6 antibody induced clearance of vascular Aβ that was spatially and temporally associated with a transient increase in microhemorrhage and in capillary Aβ deposition. Microhemorrhage resolved over a time period that was associated with a recovery of vascular morphology and a decrease in capillary Aβ accumulation. These data suggest that vascular leakage events, such as microhemorrhage, may be related to the removal of vascular Aβ. With continued treatment, this initial susceptibility period is followed by restoration of vascular morphology and reduced vulnerability to further vascular leakage events. The data collectively suggested a vascular amyloid clearance model of ARIA, which accounts for the currently known risk factors for the incidence of ARIA in clinical studies. Copyright © 2013. Published by Elsevier Inc.

  4. Differing patterns of P-selectin expression in lung injury

    DEFF Research Database (Denmark)

    Bless, N M; Tojo, S J; Kawarai, H

    1998-01-01

    Using two models of acute lung inflammatory injury in rats (intrapulmonary deposition of immunoglobulin G immune complexes and systemic activation of complement after infusion of purified cobra venom factor), we have analyzed the requirements and patterns for upregulation of lung vascular P......-selectin. In the immune complex model, upregulation of P-selectin was defined by Northern and Western blot analysis of lung homogenates, by immunostaining of lung tissue, and by vascular fixation of 125I-labeled anti-P-selectin. P-selectin protein was detected by 1 hour (long before detection of mRNA) and expression......-selectin was dependent on an intact complement system, and the presence of blood neutrophils was susceptible to the antioxidant dimethyl sulfoxide and required C5a but not tumor necrosis factor alpha. In contrast, in the cobra venom factor model, upregulation of P-selectin, which is C5a dependent, was also dimethyl...

  5. Non-vascular interventional therapy for respiratory diseases

    International Nuclear Information System (INIS)

    Ji Hongjian; Chen Liping; Wang Hui; Cheng Yongde

    2009-01-01

    To review the recent literature relating to non-vascular interventional therapy of respiratory diseases. Metal airway stent insertion can immediately relieve tracheobronchial obstruction and improve pulmonary function. However, as there is a high occurrence of the restenosis after stent insertion, it should be very careful to use metal stenting to treat the benign airway obstruction. Compared with traditional lung volume reduction surgery in treating severe emphysema, bronchoscopic lung volume reduction appears to be effective, safe and less invasive, although its clinical usefullness need to be further proved. Endoscopic occlusion of bronchial fistula represents an effective alternative to surgical treatment. Percutaneous lung biopsy under ultrasound or CT guidance has been applied successfully in the management of both benign and malignant lesions. (authors)

  6. Redistribution of Extracellular Superoxide Dismutase Causes Neonatal Pulmonary Vascular Remodeling and PH but Protects Against Experimental Bronchopulmonary Dysplasia

    Directory of Open Access Journals (Sweden)

    Laurie G. Sherlock

    2018-03-01

    Full Text Available Background: A naturally occurring single nucleotide polymorphism (SNP, (R213G, in extracellular superoxide dismutase (SOD3, decreases SOD3 matrix binding affinity. Humans and mature mice expressing the R213G SNP exhibit increased cardiovascular disease but decreased lung disease. The impact of this SNP on the neonatal lung at baseline or with injury is unknown. Methods: Wild type and homozygous R213G mice were injected with intraperitoneal bleomycin or phosphate buffered saline (PBS three times weekly for three weeks and tissue harvested at 22 days of life. Vascular and alveolar development were evaluated by morphometric analysis and immunostaining of lung sections. Pulmonary hypertension (PH was assessed by right ventricular hypertrophy (RVH. Lung protein expression for superoxide dismutase (SOD isoforms, catalase, vascular endothelial growth factor receptor 2 (VEGFR2, endothelial nitric oxide synthase (eNOS and guanosine triphosphate cyclohydrolase-1 (GTPCH-1 was evaluated by western blot. SOD activity and SOD3 expression were measured in serum. Results: In R213G mice, SOD3 lung protein expression decreased, serum SOD3 protein expression and SOD serum activity increased compared to wild type (WT mice. Under control conditions, R213G mice developed pulmonary vascular remodeling (decreased vessel density and increased medial wall thickness and PH; alveolar development was similar between strains. After bleomycin injury, in contrast to WT, R213G mice were protected from impaired alveolar development and their vascular abnormalities and PH did not worsen. Bleomycin decreased VEGFR2 and GTPCH-1 only in WT mice. Conclusion: R213G neonatal mice demonstrate impaired vascular development and PH at baseline without alveolar simplification, yet are protected from bleomycin induced lung injury and worsening of pulmonary vascular remodeling and PH. These results show that vessel bound SOD3 is essential in normal pulmonary vascular development, and

  7. 75 FR 29699 - Total Inward Leakage Requirements for Respirators

    Science.gov (United States)

    2010-05-27

    ... or other half-mask respirator inward leakage measurement, and offer any additional comments on the..., facsimile (412) 386-4089, e-mail [email protected] . SUPPLEMENTARY INFORMATION: I. Background The Department of... order to conduct tests and prepare responses. On April 20, 2010, NIOSH responded by reopening the docket...

  8. University student's education after Fukushima nuclear leakage crisis

    International Nuclear Information System (INIS)

    Dou Daying; Gu Jianzhong; Zheng Jianying

    2012-01-01

    Fukushima nuclear leakage crisis after 3.11 earthquake and tsunami, the horrible INES-7 accident warns the colleagues all over the world. Own much to the experts' reports on public media, INES classification, basic knowledge of nuclear reactor, nuclear safety and protection had been discussed and brain-stormed in detail. (authors)

  9. Leakage monitoring equipment of fuel element by delayed neutron method

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Shulan; Zhang Shuheng

    1999-01-01

    Based on monitoring results of delayed neutrons from reactor first circle water, the leakage of reactor fuel elements is monitored. A monitoring equipment consisted of an array of 3 He proportional counter tubes with 75 s delay has been developed. The neutron detection efficiency of 6.1% is obtained

  10. Benchmarking leakage from water reticulation systems in South Africa

    African Journals Online (AJOL)

    driniev

    Abstract. A project to assess the levels of leakage in 30 water utilities throughout South Africa was initiated by the Water ... average operating pressure, systems input volume and the compo- ... simple, user-friendly model that is based on an excel spreadsheet ..... One can see from the four graphs presented here that various.

  11. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  12. Reaction-driven casing expansion : potential for wellbore leakage mitigation

    NARCIS (Netherlands)

    Wolterbeek, Timotheus K. T.; van Noort, Reinier; Spiers, Christopher J.

    It is generally challenging to predict the post-abandonment behaviour and integrity of wellbores. Leakage is, moreover, difficult to mitigate, particularly between the steel casing and outer cement sheath. Radially expanding the casing with some form of internal plug, thereby closing annular voids

  13. Carbon Leakage Revisited : Unilateral Climate Policy with Directed Technical Change

    NARCIS (Netherlands)

    Di Maria, C.; van der Werf, E.H.

    2005-01-01

    The increase in carbondioxide emissions by some countries in reaction to an emission reduction by countries with climate policy (carbon leakage) is seen as a serious threat to unilateral climate policy.Using a two-country model where only one of the countries enforces an exogenous cap on emissions,

  14. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Science.gov (United States)

    2010-10-01

    ... following minimum requirements: (1) A leakage survey with leak detector equipment must be conducted in business districts, including tests of the atmosphere in gas, electric, telephone, sewer, and water system... survey with leak detector equipment must be conducted outside business districts as frequently as...

  15. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  16. Superconducting coil configurations, with low flux leakage, for energy storage

    International Nuclear Information System (INIS)

    Vincent-Viry, O.; Mailfert, A.; Trassart, D.

    2001-01-01

    This paper presents two original types of SMES structures for energy storage. These two groups of SMES structures proceeded from an ideal structure: the full toroid, are modeled by the use of purely surface current densities. Their main advantage is to present no flux leakage, they give then satisfactory solution to the problem of energy storage. (orig.)

  17. Optimized quantization in Zero Leakage Helper data systems

    NARCIS (Netherlands)

    Stanko, T.; Andini, F.N.; Skoric, B.

    2017-01-01

    Helper data systems are a cryptographic primitive that allows for the reproducible extraction of secrets from noisy measurements. Redundancy data called helper data makes it possible to do error correction while leaking little or nothing (Zero Leakage) about the extracted secret string. We study the

  18. Modelling of heterogenous neutron leakages in a nuclear reactor

    International Nuclear Information System (INIS)

    Wohleber, X.

    1997-01-01

    The TIBERE Model is a neutron leakage method based on B 1 heterogeneous transport equation resolution. In this work, we have studied the influence of the reflection mode at the boundary of the assembly. In particular the White boundary condition has been implemented in the APOLLO2 neutron transport code. We have compared the two TIBERE kinds of boundary conditions (specular and white) with the classical B 1 homogeneous leakage method in the modelling of some reactors. We have remarked the better capability of the TIBERE Model to compute voided assemblies. The white boundary condition is also able to compute a completely voided assembly and, besides, wins a factor 10 in CPU time in comparison with the specular boundary condition. These two heterogenous leakage formalisms have been tested on a partially voided experiment and have shown that the TIBERE Model can compute this kind of situation with a greater precision than the classical B 1 homogeneous leakage method, and with a shorter computational time. (author)

  19. Exploitation of Unintentional Information Leakage from Integrated Circuits

    Science.gov (United States)

    Cobb, William E.

    2011-01-01

    The information leakage of electronic devices, especially those used in cryptographic or other vital applications, represents a serious practical threat to secure systems. While physical implementation attacks have evolved rapidly over the last decade, relatively little work has been done to allow system designers to effectively counter the…

  20. Visual Inspection of Water Leakage from Ground Penetrating Radar Radargram

    Science.gov (United States)

    Halimshah, N. N.; Yusup, A.; Mat Amin, Z.; Ghazalli, M. D.

    2015-10-01

    Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR) as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD) of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  1. Leakage detection in underground gas mains with radioaktive argon

    International Nuclear Information System (INIS)

    Schmitz, J.

    1975-01-01

    In the field of gas supply, radionuclide techniques are suitable for the routine monitoring of transport mains by means of highly active tracer clouds and a measuring scraper as well as for exact leakage detection in local gas distribution systems. Very good results are obtained in the case of mains lying lower than 1.5 m if the length and alignment of the pipe section allow a towing probe to be pulled through. This was investigated systematically on a model stretch under practical conditions. The attempts to detect leakages were made with the aid of the radioactive isotope 41 Ar. Under conditions close to practice concerning pipe bedding, branching, pre-pressure, and leakage diameter, a leak with leakage rates as small as approx. 1 l/min could be measured with the aid of a towing probe with a precision of +-0.5 m. This accuracy is another advantage of this method. Branching and fittings with a big dead volume do not interfere with the evaluation. The investment for this method can be compared to other physical/technical investigations on mains, e.g. weld seam tests. (orig./LN) [de

  2. VISUAL INSPECTION OF WATER LEAKAGE FROM GROUND PENETRATING RADAR RADARGRAM

    Directory of Open Access Journals (Sweden)

    N. N. Halimshah

    2015-10-01

    Full Text Available Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  3. Colorectal anastomotic leakage: Aspects of prevention, detection and treatment

    NARCIS (Netherlands)

    F. Daams (Freek); M. Luyer (Misha); J.F. Lange (Johan)

    2013-01-01

    textabstractAll colorectal surgeons are faced from time to time with anastomotic leakage after colorectal surgery. This complication has been studied extensively without a significant reduction of incidence over the last 30 years. New techniques of prevention, by innovative anastomotic techniques

  4. First principle leakage current reduction technique for CMOS devices

    CSIR Research Space (South Africa)

    Tsague, HD

    2015-12-01

    Full Text Available This paper presents a comprehensive study of leakage reduction techniques applicable to CMOS based devices. In the process, mathematical equations that model the power-performance trade-offs in CMOS logic circuits are presented. From those equations...

  5. Incidence and management of chyle leakage after esophagectomy

    NARCIS (Netherlands)

    Lagarde, Sjoerd M.; Omloo, Jikke M. T.; de Jong, Koen; Busch, Olivier R. C.; Obertop, Hugo; van Lanschot, J. Jan B.

    2005-01-01

    BACKGROUND: Postoperative chyle leakage is a rare but well-recognized complication after esophageal surgery. The aim of this study was to identify its incidence and potentially predisposing factors and to assess the consequences and management. METHODS: A consecutive series of 536 patients who

  6. Characterization of CO2 leakage into the freshwater body

    DEFF Research Database (Denmark)

    Singh, Ashok; Delfs, Jens Olaf; Shao, H.

    2013-01-01

    urrent research into CO2 capture and storage is dominated by improving the CO2 storage capacity. In this context, risk related to CO2 leakage is an important issue which may cause environmental problems, particularly when freshwater resources nearby are intruded by the CO2 plume. In this work...

  7. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  8. The lungs

    International Nuclear Information System (INIS)

    Macey, D.J.; Marshall, R.

    1982-01-01

    Currently emission tomography of the lungs is only practical for perfusion images with sup(99m)Tc microaggregates and ventilation images with sup(81m)Kr. The following topics are touched on: the rotating gamma camera single photon ECT system, spatial resolution and linearity, resolution in phantom studies, area and volume studies, quantitation studies, with particular reference to the authors' experience of perfusion and ventilation in investigations of pulmonary embolism. (U.K.)

  9. Factors related to ostomy leakage in the community setting.

    Science.gov (United States)

    Ratliff, Catherine R

    2014-01-01

    The purpose of this study was to describe demographic and clinical variables related to ostomy pouch leakage from those discharged from a major medical center during a 2-year period. A convenience sample of 198 persons with an ostomy was obtained using the ICD-9 (International Classification of Diseases, Ninth Revision) codes for colostomy, ileostomy, and ileal conduit for patients who were discharged from the medical center within the time frame of July 2009 to July 2011. One hundred seven participants (55%) returned a completed survey. Respondents included 57 men (53%) and 50 women (47%). The mean age was 60 years with age range from 23 to 91 years. Fecal ostomies made up the majority of the stomas representing 71 patients (66%). A descriptive, cross-sectional research design was used to describe clinical variables related to ostomy pouch leakage for those discharged from a major academic medical center over a 2-year period of time. Participants were mailed an introductory letter from the principal investigator, a self-administered questionnaire, and a prepaid return envelope. Ninety-three patients (87%) reported leakage; however, 48 patients (45%) stated that they did not leak often. A logistic regression was estimated to determine which variables were significant predictors of the dependent variable of leaking status (no/seldom leaking vs more frequent leaking). Two variables were individually significant predictors, sex (P = .021) and 2-piece pouch (P = .015). Women were 4 times more likely to be in the more frequent leaking group than were men. Those who were wearing 2-piece pouches were 78% less likely to be in the more frequent leaking group. Participants with ileostomies or urostomies were more likely to be in the more frequent leaking group and those with peristomal skin irritation were more likely to be in the more frequent leaking group. Findings from this study reveal that women were more likely to experience leakage than men and that wearing a 2-piece

  10. Hyperlucent lung

    International Nuclear Information System (INIS)

    Jimenez-Gutierrez, Florana; Soto-Quiros, Manuel E.

    2007-01-01

    Unilateral hyperlucent lung is also known as Swyer-James Syndrome, Macleod Syndrome or lobular or unilateral emphysema. It is an uncommon disease characterized by lung or unilateral lobe hiperlucency associated to an air trapping upon expiration. As regards to etiology, this syndrome is considered to be an acquired disease that appears secondary to respiratory infections during the early years of life, probably bronchiolitis and/ or viral pneumonia. The clinical presentation varies among patients. Some of them are asymptomatic, others present a history of recurrent episodes of pulmonary infections from early years of life or present effort dyspnea. The diagnosis is usually made accidentally by a chest radiograph in a child with history of respiratory infections or in an adult during a routine chest x- ray in an asymptomatic person. It is important to differentiate this syndrome from other causes of unilateral pulmonary hiperlucency on conventional chest x-rays. Few cases of Swyer-James Syndrome in children have been reported, it is presented the clinical case of a patient who had a parainfluenza 3 bronchopneumonia when he was a month and eighteen days of age. The differential diagnosis of this syndrome should be done with other thoracic entities that diminish the radiological pulmonary unilateral density. A case of a child who is the bearer of hyperlucent lung is described. (author) [es

  11. Subclinical pulmonary involvement in collagen vascular diseases

    International Nuclear Information System (INIS)

    Dansin, E.; Wallaert, B.; Jardin, M.R.; Remy, J.; Hatron, P.Y.; Tonnel, A.B.

    1990-01-01

    A recruitment of immune and inflammatory cells into alveolar spaces has been reported in patients with collagen vascular diseases (CVD) and a normal chest radiograph. These findings defined the concept of subclinical alveolitis (SCA). To determine whether SCA may be associated with CT signs of interstitial lung disease (ILD), the authors of this paper compared bronchoalveolar lavage (BAL) findings and high-resolution (HRCT) scans in 36 patients with CVD and normal chest radiographs (systemic sclerosis [SS, n = 21], rheumatoid arthritis [RA, n = 9], primary Sjogren's syndrome [PS, n = 6]). HRCT scans were obtained in supine and prone positions. Results of BAL revealed SCA in 17/36 patients (47%); lymphocyte SCA in 4/36 (24%); neutrophil SCA in 7/36 (41%); and mixed SCA in 6/36 (35%)

  12. Understanding and managing leakage in forest-based greenhouse-gas-mitigation projects.

    Science.gov (United States)

    Schwarze, Reimund; Niles, John O; Olander, Jacob

    2002-08-15

    A major concern about land use, land-use change and forestry (LULUCF) projects under the Clean Development Mechanism (CDM) is the potential for leakage. Leakage refers to a net increase of greenhouse-gas emissions in an area outside the project resulting from the CDM activity. This paper provides an overview of leakage, its definitions and its causes. It describes ways that LULUCF projects may suffer from leakage and attempts to assess the magnitude of leakage risks for different LULUCF project types. It also summarizes some of the approaches, both in terms of policies and project development, to address LULUCF leakage.

  13. Early detection of anastomotic leakage after elective low anterior resection.

    Science.gov (United States)

    Fouda, Elyamani; El Nakeeb, Ayman; Magdy, Alaa; Hammad, Enas A; Othman, Gamal; Farid, Mohamed

    2011-01-01

    Colorectal anastomotic leakage is a serious complication leading to major postoperative morbidity and mortality. In the present study, we investigated the early detection of anastomotic leakage before its clinical presentation. Fifty-six patients with rectal cancer were included prospectively in this study. All patients underwent elective low anterior resection. Peritoneal samples were collected from the abdominal drains at the first, third, and fifth days postoperatively for bacteriological study (quantitative cultures for both aerobes and anaerobes) and cytokines (IL-6, IL-10, TNF) measurement. Patients were divided into two groups: those without symptomatic or clinical evidence of anastomotic leakage (AL; group 1) and those with clinical evidence of AL (group 2). Study variables included hospital stay, wound infection, operative time, blood loss, height of anastomosis, intraperitoneal cytokines, and microbiological study of peritoneal fluid. Clinically evident AL occurred in eight patients (14.3%) and diagnosed postoperatively on median day 6. Intraperitoneal bacterial colonization and cytokine levels were significantly higher in patients with clinical evidence of AL. Wound infection was significantly higher in anastomotic leakage group. The hospital stay for the patients with anastomotic leakage was significantly longer than those without AL (14 ± 1.41 vs. 5.43 ± 0.89 days). A significant difference among two groups was observed regarding operative time, blood loss, blood transfusion, and height of the anastomosis. The peritoneal cytokines levels and intraperitoneal bacterial colonization might be an additional diagnostic tool that can support the decision making of surgeons for early detection of anastomotic leak in colorectal surgery.

  14. Vascular remodeling and mineralocorticoids.

    Science.gov (United States)

    Weber, K T; Sun, Y; Campbell, S E; Slight, S H; Ganjam, V K

    1995-01-01

    Circulating mineralocorticoid hormones are so named because of their important homeostatic properties that regulate salt and water balance via their action on epithelial cells. A broader range of functions in nonclassic target cellular sites has been proposed for these steroids and includes their contribution to wound healing following injury. A chronic, inappropriate (relative to intravascular volume and dietary sodium intake) elevation of these circulating hormones evokes a wound healing response in the absence of tissue injury--a wound healing response gone awry. The adverse remodeling of vascularized tissues seen in association with chronic mineralocorticoid excess is the focus of this review.

  15. Measurements of pulmonary vascular permeability with PET and gallium-68 transferrin

    International Nuclear Information System (INIS)

    Mintun, M.A.; Dennis, D.R.; Welch, M.J.; Mathias, C.J.; Schuster, D.P.

    1987-01-01

    We quantified pulmonary vascular permeability with positron emission tomography (PET) and gallium-68-( 68 Ga) labeled transferrin. Six dogs with oleic acid-induced lung injury confined to the left lower lobe, two normal human volunteers, and two patients with the adult respiratory distress syndrome (ARDS) were evaluated. Lung tissue-activity measurements were obtained from sequential 1-5 min PET scans collected over 60 min, after in vivo labeling of transferrin through intravenous administration of [ 68 Ga]citrate. Blood-activity measurements were measured from simultaneously obtained peripheral blood samples. A forward rate constant describing the movement of transferrin from pulmonary vascular to extravascular compartments, the pulmonary transcapillary escape rate (PTCER), was then calculated from these data using a two-compartment model. In dogs, PTCER was 49 +/- 18 in normal lung tissue and 485 +/- 114 10(-4) min-1 in injured lung. A repeat study in these dogs 4 hr later showed no significant change. Values in the human subjects showed similarly marked differences between normal and abnormal lung tissue. We conclude that PET will be a useful method of evaluating vascular permeability changes after acute lung injury

  16. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario.

    Science.gov (United States)

    Ma, Jing; Zhang, Wangyuan; Zhang, Shaoliang; Zhu, Qianlin; Feng, Qiyan; Chen, Fu

    2017-01-01

    The technology of carbon dioxide (CO 2 ) capture and storage (CCS) has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO 2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO 2 geological storage was designed to investigate the short-term effects of different CO 2 leakage concentration (from 400 g m -2 day -1 to 2,000 g m -2 day -1 ) on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO 2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO 2 concentrations. Increasing CO 2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 ( p soil CO 2 concentration increased. The dominant phylum in the soil samples was Proteobacteria , whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% ( p soil ecosystems.

  17. Surgical management for the first 48 h following blunt chest trauma: state of the art (excluding vascular injuries).

    Science.gov (United States)

    de Lesquen, Henri; Avaro, Jean-Philippe; Gust, Lucile; Ford, Robert Michael; Beranger, Fabien; Natale, Claudia; Bonnet, Pierre-Mathieu; D'Journo, Xavier-Benoît

    2015-03-01

    This review aims to answer the most common questions in routine surgical practice during the first 48 h of blunt chest trauma (BCT) management. Two authors identified relevant manuscripts published since January 1994 to January 2014. Using preferred reporting items for systematic reviews and meta-analyses statement, they focused on the surgical management of BCT, excluded both child and vascular injuries and selected 80 studies. Tension pneumothorax should be promptly diagnosed and treated by needle decompression closely followed with chest tube insertion (Grade D). All traumatic pneumothoraces are considered for chest tube insertion. However, observation is possible for selected patients with small unilateral pneumothoraces without respiratory disease or need for positive pressure ventilation (Grade C). Symptomatic traumatic haemothoraces or haemothoraces >500 ml should be treated by chest tube insertion (Grade D). Occult pneumothoraces and occult haemothoraces are managed by observation with daily chest X-rays (Grades B and C). Periprocedural antibiotics are used to prevent chest-tube-related infectious complications (Grade B). No sign of life at the initial assessment and cardiopulmonary resuscitation duration >10 min are considered as contraindications of Emergency Department Thoracotomy (Grade C). Damage Control Thoracotomy is performed for either massive air leakage or refractive shock or ongoing bleeding enhanced by chest tube output >1500 ml initially or >200 ml/h for 3 h (Grade D). In the case of haemodynamically stable patients, early video-assisted thoracic surgery is performed for retained haemothoraces (Grade B). Fixation of flail chest can be considered if mechanical ventilation for 48 h is probably required (Grade B). Fixation of sternal fractures is performed for displaced fractures with overlap or comminution, intractable pain or respiratory insufficiency (Grade D). Lung herniation, traumatic diaphragmatic rupture and pericardial rupture are life

  18. Radiation leakage dose from Elekta electron collimation system.

    Science.gov (United States)

    Pitcher, Garrett M; Hogstrom, Kenneth R; Carver, Robert L

    2016-09-08

    This study provided baseline data required for a greater project, whose objective was to design a new Elekta electron collimation system having significantly lighter electron applicators with equally low out-of field leakage dose. Specifically, off-axis dose profiles for the electron collimation system of our uniquely configured Elekta Infinity accelerator with the MLCi2 treatment head were measured and calculated for two primary purposes: 1) to evaluate and document the out-of-field leakage dose in the patient plane and 2) to validate the dose distributions calculated using a BEAMnrc Monte Carlo (MC) model for out-of-field dose profiles. Off-axis dose profiles were measured in a water phantom at 100 cm SSD for 1 and 2 cm depths along the in-plane, cross-plane, and both diagonal axes using a cylindrical ionization chamber with the 10 × 10 and 20 × 20 cm2 applicators and 7, 13, and 20 MeV beams. Dose distributions were calculated using a previously developed BEAMnrc MC model of the Elekta Infinity accelerator for the same beam energies and applicator sizes and compared with measurements. Measured results showed that the in-field beam flatness met our acceptance criteria (± 3% on major and ±4% on diagonal axes) and that out-of-field mean and maximum percent leakage doses in the patient plane met acceptance criteria as specified by the International Electrotechnical Commission (IEC). Cross-plane out-of-field dose profiles showed greater leakage dose than in-plane profiles, attributed to the curved edges of the upper X-ray jaws and multileaf collimator. Mean leakage doses increased with beam energy, being 0.93% and 0.85% of maximum central axis dose for the 10 × 10 and 20 × 20 cm2 applicators, respectively, at 20 MeV. MC calculations predicted the measured dose to within 0.1% in most profiles outside the radiation field; however, excluding model-ing of nontrimmer applicator components led to calculations exceeding measured data by as much as 0.2% for some regions

  19. Interventional vascular radiology

    International Nuclear Information System (INIS)

    Yune, H.Y.

    1984-01-01

    The papers published during this past year in the area of interventional vascular radiology presented some useful modifications and further experiences both in the area of thromboembolic therapy and in dilation and thrombolysis, but no new techniques. As an introductory subject, an excellent monograph reviewing the current spectrum of pharmacoangiography was presented in Radiographics. Although the presented material is primarily in diagnostic application of various pharmacologic agents used today to facilitate demonstration of certain diagnostic criteria of various disease processes, both vasodilatory and vasoconstrictive reaction to these agents are widely used in various therapeutic vascular procedures. This monograph should be reviewed by every angiographer whether or not he or she performs interventional procedures, and it would be very convenient to have this table available in the angiography suite. In a related subject, Bookstein and co-workers have written an excellent review concerning pharmacologic manipulations of various blood coagulative parameters during angiography. Understanding the proper method of manipulation of the bloodclotting factors during angiography, and especially during interventional angiography, is extremely important. Particularly, the method of manipulating the coagulation with the use of heparin and protamine and modification of the platelet activity by using aspirin and dipyridamole are succinctly reviewed. The systemic and selective thrombolytic activities of streptokianse are also discussed

  20. Vascular dysfunction in preeclampsia.

    Science.gov (United States)

    Brennan, Lesley J; Morton, Jude S; Davidge, Sandra T

    2014-01-01

    Preeclampsia is a complex disorder which affects an estimated 5% of all pregnancies worldwide. It is diagnosed by hypertension in the presence of proteinuria after the 20th week of pregnancy and is a prominent cause of maternal morbidity and mortality. As delivery is currently the only known treatment, preeclampsia is also a leading cause of preterm delivery. Preeclampsia is associated with maternal vascular dysfunction, leading to serious cardiovascular risk both during and following pregnancy. Endothelial dysfunction, resulting in increased peripheral resistance, is an integral part of the maternal syndrome. While the cause of preeclampsia remains unknown, placental ischemia resulting from aberrant placentation is a fundamental characteristic of the disorder. Poor placentation is believed to stimulate the release of a number of factors including pro- and antiangiogenic factors and inflammatory activators into the maternal systemic circulation. These factors are critical mediators of vascular function and impact the endothelium in distinctive ways, including enhanced endothelial oxidative stress. The mechanisms of action and the consequences on the maternal vasculature will be discussed in this review. © 2013 John Wiley & Sons Ltd.

  1. Vascular Remodeling in Experimental Hypertension

    Directory of Open Access Journals (Sweden)

    Norma R. Risler

    2005-01-01

    Full Text Available The basic hemodynamic abnormality in hypertension is an increased peripheral resistance that is due mainly to a decreased vascular lumen derived from structural changes in the small arteries wall, named (as a whole vascular remodeling. The vascular wall is an active, flexible, and integrated organ made up of cellular (endothelial cells, smooth muscle cells, adventitia cells, and fibroblasts and noncellular (extracellular matrix components, which in a dynamic way change shape or number, or reorganize in response to physiological and pathological stimuli, maintaining the integrity of the vessel wall in physiological conditions or participating in the vascular changes in cardiovascular diseases such as hypertension. Research focused on new signaling pathways and molecules that can participate in the mechanisms of vascular remodeling has provided evidence showing that vascular structure is not only affected by blood pressure, but also by mechanisms that are independent of the increased pressure. This review will provide an overview of the evidence, explaining some of the pathophysiologic mechanisms participating in the development of the vascular remodeling, in experimental models of hypertension, with special reference to the findings in spontaneously hypertensive rats as a model of essential hypertension, and in fructose-fed rats as a model of secondary hypertension, in the context of the metabolic syndrome. The understanding of the mechanisms producing the vascular alterations will allow the development of novel pharmacological tools for vascular protection in hypertensive disease.

  2. Vascular pattern formation in plants.

    Science.gov (United States)

    Scarpella, Enrico; Helariutta, Ykä

    2010-01-01

    Reticulate tissue systems exist in most multicellular organisms, and the principles underlying the formation of cellular networks have fascinated philosophers, mathematicians, and biologists for centuries. In particular, the beautiful and varied arrangements of vascular tissues in plants have intrigued mankind since antiquity, yet the organizing signals have remained elusive. Plant vascular tissues form systems of interconnected cell files throughout the plant body. Vascular cells are aligned with one another along continuous lines, and vascular tissues differentiate at reproducible positions within organ environments. However, neither the precise path of vascular differentiation nor the exact geometry of vascular networks is fixed or immutable. Several recent advances converge to reconcile the seemingly conflicting predictability and plasticity of vascular tissue patterns. A control mechanism in which an apical-basal flow of signal establishes a basic coordinate system for body axis formation and vascular strand differentiation, and in which a superimposed level of radial organizing cues elaborates cell patterns, would generate a reproducible tissue configuration in the context of an underlying robust, self-organizing structure, and account for the simultaneous regularity and flexibility of vascular tissue patterns. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Physiological and biochemical aspects of the effect of ionizing radiations on the lung parenchyma

    International Nuclear Information System (INIS)

    Pasquier, Christian.

    1975-03-01

    Concerning the biochemical reactions of the lung parenchyma to irradiation the following points have been developed. Role of biochemically active substances (histamine, serotonin, kinins, catecholamines, prostaglandins) in the early reaction of the lung to irradiation, their common feature being their vascular impact point. Lung irradiation and lipids (fatty acids and lipid metabolism in general); irradiation, by raising the proportion of unsaturated at the expense of saturated fatty acids, may give rise to serious physiological respiratory disorders. Lung irradiation and blood fluidity (fibrinolytic activity, heparin, platelet factors). Pulmonary interstitium and irradiation (of the three interstitium components collagen plays a preferential part). Irradiation and immunological lung reaction (reasons behind the immunological theory, immunological assistance, immunological mechanism of pulmonary reactions towards pollutants). Enzymatic lung radiolesion indicators. Three kinds of physiological changes have been considered. Vascular physiology disturbances caused by the initial biochemical reactions; anomalies of physiological or functional trials, images of the lesion formed; disorders of the cell physiology of carcinogenesis [fr

  4. Vascular dysfunction by myofibroblast activation in patients with idiopathic pulmonary fibrosis and prognostic significance

    Directory of Open Access Journals (Sweden)

    E.R. Parra

    2012-07-01

    Full Text Available In this study, we demonstrated the importance of telomerase protein expression and determined the relationships among telomerase, endothelin-1 (ET-1 and myofibroblasts during early and late remodeling of parenchymal and vascular areas in usual interstitial pneumonia (UIP using 27 surgical lung biopsies from patients with idiopathic pulmonary fibrosis (IPF. Telomerase+, myofibroblasts α-SMA+, smooth muscle cells caldesmon+, endothelium ET-1+ cellularity, and fibrosis severity were evaluated in 30 fields covering normal lung parenchyma, minimal fibrosis (fibroblastic foci, severe (mural fibrosis, and vascular areas of UIP by the point-counting technique and a semiquantitative score. The impact of these markers was determined in pulmonary functional tests and follow-up until death from IPF. Telomerase and ET-1 expression was significantly increased in normal and vascular areas compared to areas of fibroblast foci. Telomerase and ET-1 expression was inversely correlated with minimal fibrosis in areas of fibroblast foci and directly associated with severe fibrosis in vascular areas. Telomerase activity in minimal fibrosis areas was directly associated with diffusing capacity of the lung for oxygen/alveolar volume and ET-1 expression and indirectly associated with diffusing capacity of the lungs for carbon monoxide and severe fibrosis in vascular areas. Cox proportional hazards regression revealed a low risk of death for females with minimal fibrosis displaying high telomerase and ET-1 expression in normal areas. Vascular dysfunction by telomerase/ET-1 expression was found earlier than vascular remodeling by myofibroblast activation in UIP with impact on IPF evolution, suggesting that strategies aimed at preventing the effect of these mediators may have a greater impact on patient outcome.

  5. Metastatic tumors of lungs

    International Nuclear Information System (INIS)

    Rozenshtraukh, L.C.; Rybakova, N.I.; Vinner, M.G.

    1987-01-01

    Roentgenologic semiotics of lung metastases and their complications, as well as peculiarities of lung metastases of separate localization tumours are presented. Definition table for primary tumour by roentgenologic aspect of lung metastases is given

  6. How Lungs Work

    Science.gov (United States)

    ... Diseases > How Lungs Work How Lungs Work The Respiratory System Your lungs are part of the respiratory system, ... your sense of smell. The Parts of the Respiratory System and How They Work Airways SINUSES are hollow ...

  7. Protecting Your Lungs

    Science.gov (United States)

    ... lung capacity. Specific breathing exercises can also help improve your lung function if you have certain lung diseases, like COPD. Exercise and breathing techniques are also great for improving your mood and helping you relax. Public Health and Your ...

  8. Perioperative Statin Therapy Is Not Associated With Reduced Risk of Anastomotic Leakage After Colorectal Resection

    DEFF Research Database (Denmark)

    Bisgård, Anne Sofie; Noack, Morten Westergaard; Klein, Mads

    2013-01-01

    Anastomotic leakage is a serious complication of colorectal surgery. Several studies have demonstrated the beneficial pleiotropic effects of statins, and preliminary studies have suggested that perioperative statin treatment may be associated with reduced risk of anastomotic leakage....

  9. Additive Manufacturing of Vascular Grafts and Vascularized Tissue Constructs.

    Science.gov (United States)

    Elomaa, Laura; Yang, Yunzhi Peter

    2017-10-01

    There is a great need for engineered vascular grafts among patients with cardiovascular diseases who are in need of bypass therapy and lack autologous healthy blood vessels. In addition, because of the severe worldwide shortage of organ donors, there is an increasing need for engineered vascularized tissue constructs as an alternative to organ transplants. Additive manufacturing (AM) offers great advantages and flexibility of fabrication of cell-laden, multimaterial, and anatomically shaped vascular grafts and vascularized tissue constructs. Various inkjet-, extrusion-, and photocrosslinking-based AM techniques have been applied to the fabrication of both self-standing vascular grafts and porous, vascularized tissue constructs. This review discusses the state-of-the-art research on the use of AM for vascular applications and the key criteria for biomaterials in the AM of both acellular and cellular constructs. We envision that new smart printing materials that can adapt to their environment and encourage rapid endothelialization and remodeling will be the key factor in the future for the successful AM of personalized and dynamic vascular tissue applications.

  10. A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB

    Directory of Open Access Journals (Sweden)

    Chu-Wen Li

    2015-01-01

    Full Text Available A standardized traditional Chinese medicine preparation named Yejuhua capsule (YJH has been clinically used in treatments of various acute respiratory system diseases with high efficacy and low toxicity. In this study, we were aiming to evaluate potential effects and to elucidate underlying mechanisms of YJH against lipopolysaccharide- (LPS- induced acute lung injury (ALI in mice. Moreover, the chemical analysis and chromatographic fingerprint study were performed for quality evaluation and control of this drug. ALI was induced by intratracheal instillation of LPS (5 mg/kg into the lung in mice and dexamethasone (5 mg/kg, p.o. was used as a positive control drug. Results demonstrated that pretreatments with YJH (85, 170, and 340 mg/kg, p.o. effectively abated LPS-induced histopathologic changes, attenuated the vascular permeability enhancement and edema, inhibited inflammatory cells migrations and protein leakages, suppressed the ability of myeloperoxidase, declined proinflammatory cytokines productions, and downregulated activations of nuclear factor-κB (NF-κB and expressions of toll-like receptor 4 (TLR4. This study demonstrated that YJH exerted potential protective effects against LPS-induced ALI in mice and supported that YJH was a potential therapeutic drug for ALI in clinic. And its mechanisms were at least partially associated with downregulations of TLR4/NF-κB pathways.

  11. Contrast-enhanced MRI of the lung

    International Nuclear Information System (INIS)

    Kauczor, Hans-Ulrich; Kreitner, Karl-Friedrich

    2000-01-01

    The lung has long been neglected by MR imaging. This is due to unique intrinsic difficulties: (1) signal loss due to cardiac pulsation and respiration; (2) susceptibility artifacts caused by multiple air-tissue interfaces; (3) low proton density. There are many MR strategies to overcome these problems. They consist of breath-hold imaging, respiratory and cardiac gating procedures, use of short repetition and echo times, increase of the relaxivity of existing spins by administration of intravenous contrast agents, and enrichment of spin density by hyperpolarized noble gases or oxygen. Improvements in scanner performance and frequent use of contrast media have increased the interest in MR imaging and MR angiography of the lung. They can be used on a routine basis for the following indications: characterization of pulmonary nodules, staging of bronchogenic carcinoma, in particular assessment of chest wall invasion; evaluation of inflammatory activity in interstitial lung disease; acute pulmonary embolism, chronic thromboembolic pulmonary hypertension, vascular involvement in malignant disease; vascular abnormalities. Future perspectives include perfusion imaging using extracellular or intravascular (blood pool) contrast agents and ventilation imaging using inhalation of hyperpolarized noble gases, of paramagnetic oxygen or of aerosolized contrast agents. These techniques represent new approaches to functional lung imaging. The combination of visualization of morphology and functional assessment of ventilation and perfusion is unequalled by any other technique

  12. Pathology of radiation induced lung damage

    International Nuclear Information System (INIS)

    Kawabata, Yoshinori; Murata, Yoshihiko; Ogata, Hideo; Katagiri, Shiro; Sugita, Hironobu; Iwai, Kazuo; Sakurai, Isamu.

    1985-01-01

    We examined pathological findings of radiation induced lung damage. Twenty-three cases are chosen from our hospital autopsy cases for 9 years, which fulfil strict criteria of radiation lung damage. Lung damage could be classified into 3 groups : 1) interstitial pneumonia type (9 cases), 2) intermediate pneumonia type (8 cases), and 3) alveolar pneumonia type (6 cases), according to the degree of intra-luminal exudation. These classification is well correlated with clinical findings. Pathological alveolar pneumonia type corresponds to symptomatic, radiologic ground glass pneumonic shadow. And pathologic interstitial type corresponds to clinical asymptomatic, radiologic reticulo-nodular shadow. From the clinico-pathological view point these classification is reasonable one. Radiation affects many lung structures and showed characteristic feature of repair. Elastofibrosis of the alveolar wall is observed in every cases, obstructive bronchiolitis are observed in 5 cases, and obstructive bronchiolitis in 9 cases. They are remarkable additional findings. Thickening of the interlobular septum, broncho-vascular connective tissue, and pleural layer are observed in every cases together with vascular lesions. (author)

  13. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events

    OpenAIRE

    Axelsson, Charles; van Sebille, Erik

    2017-01-01

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while c...

  14. Evaluation of the White Test for the Intraoperative Detection of Bile Leakage

    OpenAIRE

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was c...

  15. Lung congestion in chronic heart failure: haemodynamic, clinical, and prognostic implications

    DEFF Research Database (Denmark)

    Melenovsky, Vojtech; Andersen, Mads Jønsson; Andress, Krystof

    2015-01-01

    AIMS:The goal of the study was to examine the prognostic impact, haemodynamic and clinical features associated with lung congestion in patients with chronic heart failure (HF). METHODS AND RESULTS:HF patients (n = 186) and HF-free controls (n = 21) underwent right heart catheterization...... days (interquartile range 80-875), 59 patients (32%) died. Lung congestion was associated with reduced survival (P renal dysfunction. CONCLUSION:Interstitial lung oedema is associated with pulmonary vascular disease, RV overload...

  16. Artificial life models in lung CTS

    International Nuclear Information System (INIS)

    Sorin, Cheran

    2006-01-01

    A new method for the analysis of 3D medical images is introduced. The algorithm is based on Biological Models of ants known as Artificial Life models. Test images (lung Computed Tomographies) undergo a 3D region growing procedure for the identification of the ribs cage. Active Contour Models (snakes) are used in order to build a confined area where ants are deployed. The ant-based approach, in which steps are allowed in any direction with different probabilities, allows a kind of tunneling effect for the successful identification of small 3D structures that are not clearly connected to the rest of the tree. The best approach is based on a gradient rule for the release of pheromone. A possible application, as part of a Computer Assisted Detection system for the identification of lung nodules, is the removal of the bronchial and vascular tree from lung CTs thus reducing the number of false positives a Nodule Hunter might report. (Full Text)

  17. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  18. Allocation of emission permits with leakage through capital markets

    International Nuclear Information System (INIS)

    Maestad, Ottar

    2007-01-01

    This paper analyses how tradable emission permits should be allocated to firms when capital is internationally mobile. When international environmental problems are attempted solved through uncoordinated policies between countries, it might be desirable for the home country to issue free emission permits in proportion to the use of capital in order to prevent leakage through international capital movements. The desirability of free emission permits will however be reduced if capital also can be employed in a domestic non-polluting sector. In this case, it may even be optimal to tax the use of capital in the polluting sector. It is also shown that it is always optimal to subsidise the use of capital in the polluting sector if the use of labour is taxed at an optimal rate. Finally, leakage does not affect the optimal domestic emission limit as long as appropriate capital subsidies and labour taxes are implementeed. (author)

  19. Impact of the Indonesian Throughflow on Agulhas leakage

    Directory of Open Access Journals (Sweden)

    D. Le Bars

    2013-09-01

    Full Text Available Using ocean models of different complexity we show that opening the Indonesian Passage between the Pacific and the Indian oceans increases the input of Indian Ocean water into the South Atlantic via the Agulhas leakage. In a strongly eddying global ocean model this response results from an increased Agulhas Current transport and a constant proportion of Agulhas retroflection south of Africa. The leakage increases through an increased frequency of ring shedding events. In an idealized two-layer and flat-bottom eddy resolving model, the proportion of the Agulhas Current transport that retroflects is (for a wide range of wind stress forcing not affected by an opening of the Indonesian Passage. Using a comparison with a linear model and previous work on the retroflection problem, the result is explained as a balance between two mechanisms: decrease retroflection due to large-scale momentum balance and increase due to local barotropic/baroclinic instabilities.

  20. Combined approach to reduced duration integrated leakage rate testing

    International Nuclear Information System (INIS)

    Galanti, P.J.

    1987-01-01

    Even though primary reactor containment allowable leakage rates are expressed in weight percent per day of contained air, engineers have been attempting to define acceptable methods to test in < 24 h as long as these tests have been performed. The reasons to reduce testing duration are obvious, because time not generating electricity is time not generating revenue for the utilities. The latest proposed revision to 10CFR50 Appendix J, concerning integrated leakage rate testing (ILRTs), was supplemented with a draft regulatory guide proposing yet another method. This paper proposes a method that includes elements of currently accepted concepts for short duration testing with a standard statistical check for criteria acceptance. Following presentation of the method, several cases are presented showing the results of these combined criteria

  1. Correlation among ESDD, NSDD and leakage current in distribution insulators

    International Nuclear Information System (INIS)

    Montoya, G.; Ramirez, I.; Montoya, J.I.

    2004-01-01

    The maintenance of distribution networks is more effective if the insulation contamination levels are known. The selection of measuring methods of pollution levels is then crucial. The relationship between several evaluation methods of pollution levels and the operating behaviour of several insulator profiles in a polluted zone is described. Laboratory tests were carried out to reproduce pollution levels found in the field. The quantity of non-soluble materials deposited over the insulators' surface affect the magnitude of the leakage current generated over a contaminated insulator. The relationship that defines leakage current with respect to the equivalent salt deposit density (ESDD) level for a specific non-soluble material level is almost linear, from which it is possible to develop a relationship between them for each insulator. (author)

  2. Support calculations for management of PRISE leakage accidents

    Energy Technology Data Exchange (ETDEWEB)

    Matejovic, P.; Vranka, L. [Nuclear Power Plants Research Inst. Vuje, Trnava (Slovakia)

    1997-12-31

    Accidents involving primary-to-secondary leakage (PRISE) caused by rupture of one or a few tubes are well known design basis events in both, western and VVER NPPs. Operating experience and in-service inspections of VVER-440 units have demonstrated also the potential for large PRISE leaks in the case of the steam generator (SG) primary collector cover lift-up (Rovno NPP). Without performing any countermeasure for limitation of SG collector cover lift-up, a full opening results in PRISE leak with an equivalent diameter 107 mm. Although this accident was not considered in the original design, this event is usually analysed as DBA too. Different means are available for detection and mitigation of PRISE leakage in NPPs currently in operation (J.Bohunice V-1 and V-2) or under construction (Mochovce) in Slovakia. 8 refs.

  3. Low-leakage, high-current power crowbar transformer

    International Nuclear Information System (INIS)

    Buck, R.T.; Galbraith, J.D.; Nunnally, W.C.

    1979-01-01

    The design, fabrication, and testing of two sizes of power crowbar transformers for the ZT-40 Toroidal Z-Pinch experiment at the Los Alamos Scientific Laboratory are described. Low-leakage transformers in series with the poloidal and the toroidal field coils are used to sustain magnetic field currents initially produced by 50-kV capacitor banks. The transformer primaries are driven by cost-effective, ignitron-switched, 10-kV high-density capacitor banks. The transformer secondaries, in series with the field coils, provide from 1,000 to 1,500 V to cancel the resistive voltage drop in the coil circuits. Prototype transformers, with a total leakage inductance measured in the secondary of 5 nH, have been tested with peak secondary currents in excess of 600 kA resulting from a 10-kV primary charge voltage. The test procedures and results and the mechanical construction details are presented

  4. The Impact of Statistical Leakage Models on Design Yield Estimation

    Directory of Open Access Journals (Sweden)

    Rouwaida Kanj

    2011-01-01

    Full Text Available Device mismatch and process variation models play a key role in determining the functionality and yield of sub-100 nm design. Average characteristics are often of interest, such as the average leakage current or the average read delay. However, detecting rare functional fails is critical for memory design and designers often seek techniques that enable accurately modeling such events. Extremely leaky devices can inflict functionality fails. The plurality of leaky devices on a bitline increase the dimensionality of the yield estimation problem. Simplified models are possible by adopting approximations to the underlying sum of lognormals. The implications of such approximations on tail probabilities may in turn bias the yield estimate. We review different closed form approximations and compare against the CDF matching method, which is shown to be most effective method for accurate statistical leakage modeling.

  5. Modelling of Consequences of Biogas Leakage from Gasholder

    Directory of Open Access Journals (Sweden)

    Petr Trávníček

    2017-03-01

    Full Text Available This paper describes modelling of consequences of biogas leakage from a gasholder on agricultural biogas station. Four scenarios were selected for the purpose of this work. A rupture of gasholders membrane and instantaneous explosion of gas cloud, blast of gas with delay, emptying of whole volume of gas (without initiation and initiation of gas with Jet-Fire. Leakage of gas is modelled by special software and consequences are determined on the basis of results. The first scenario was modelled with help of equations because used software does not include an appropriate model. A farm with high building density was chosen as a model case. Biogas is replaced by methane because used software does not support modelling of dispersion of mixtures. From this viewpoint, a conservative approach is applied because biogas contains “only” approximately 60% of methane (in dependence on technology and processed material.

  6. Mission analysis report for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides an analysis of the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall missions of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineers principles are being applied to this effort. Mission analysis supports early decision making by clearly defining program objectives. This documents identifies the initial conditions and acceptable final conditions, defines the programmatic and physical interfaces and constraints, estimates the resources to carry out the mission, and establishes measures of success. The results of the mission analysis provide a consistent basis for subsequent systems engineering work

  7. The root caused analysis of leakaged heat exchanger tube

    International Nuclear Information System (INIS)

    Shamsudin, Shaiful Rizam; Salleh, M.A.A. Mohd; Rahmat, Azmi; Anuar, Mohd Arif; Harun, Mohd; Zayid, Hafizal; Noor, Mazlee Mohd

    2015-01-01

    AISI type 316L stainless steel was used as a heat exchanger tube material in an inter-cooler column. After less than a year of operation, severe corrosion failures occurred and a transverse opening leakage was observed on one of the heat exchanger tubes. The failed tube was carefully analyzed using various metallurgical laboratory equipments. The root cause of the tube leakage was believed due to the presence of horizontal micro and macro pores as a hydrogen gas entrapment during casting of the parent ingot. The overlapped and gaping pores formed notch on the shell side of the tube surface, and it increasingly evident when the use of a high-energy water-jet and metal brush as cleaning procedure results in an establishment of pitting type local-action corrosion cells penetrated the tube wall. As a result, corrosive fluid in the tube side dissolved into the cooling water, accelerating the corrosion process.

  8. A software sampling frequency adaptive algorithm for reducing spectral leakage

    Institute of Scientific and Technical Information of China (English)

    PAN Li-dong; WANG Fei

    2006-01-01

    Spectral leakage caused by synchronous error in a nonsynchronous sampling system is an important cause that reduces the accuracy of spectral analysis and harmonic measurement.This paper presents a software sampling frequency adaptive algorithm that can obtain the actual signal frequency more accurately,and then adjusts sampling interval base on the frequency calculated by software algorithm and modifies sampling frequency adaptively.It can reduce synchronous error and impact of spectral leakage;thereby improving the accuracy of spectral analysis and harmonic measurement for power system signal where frequency changes slowly.This algorithm has high precision just like the simulations show,and it can be a practical method in power system harmonic analysis since it can be implemented easily.

  9. Remote laser detection of natural gas leakages from pipelines

    International Nuclear Information System (INIS)

    Petukhov, V O; Gorobets, V A; Andreev, Yu M; Lanskii, G V

    2010-01-01

    A differential absorption lidar based on a tunable TEA CO 2 laser emitting at 42 lines of the 'hot' 01 1 1 - 11 1 0 band in the range from 10.9 to 11.4 μm is developed for detecting natural gas leakages from oil pipelines by measuring the ethane content in the atmosphere. The ethane detection sensitivity is 0.9 ppm km. The presence of methane does not distort the measurement results. The developed lidar can detect the natural gas leakage from kilometre heights at the flying velocities up to 200 km h -1 and a probe pulse repetition rate of 5 Hz. (laser applications and other topics in quantum electronics)

  10. Model-Based Detection of Pipe Leakage at Joints

    International Nuclear Information System (INIS)

    Kim, Taejin; Youn, Byeng D.; Woo, Sihyong

    2015-01-01

    Time domain reflectometry (TDR) is widely used for wire failure detection. It transmits a pulse that is reflected at the boundaries of different characteristic impedances. By analyzing the reflected signal, TDR makes it possible to locate the failure. In this study, TDR was used to detect the water leakage at a pipe joint. A wire attached to the pipe surface was soaked by water when a leak occurred, which affected the characteristic impedance of the wet part, resulting in a change in the reflected signal. To infer the leakage from the TDR signal, we first developed a finite difference time domain-based forward model that provided the output of the TDR signal given the configuration of the transmission line. Then, by solving the inverse problem, the locations of the leaks were found

  11. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran (Univ. of Gaevle, Gaevle (Sweden)); Meijer, Jan-Erik; Rosqvist, Haakan (NSR AB, Helsingborg (Sweden))

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  12. Support calculations for management of PRISE leakage accidents

    Energy Technology Data Exchange (ETDEWEB)

    Matejovic, P; Vranka, L [Nuclear Power Plants Research Inst. Vuje, Trnava (Slovakia)

    1998-12-31

    Accidents involving primary-to-secondary leakage (PRISE) caused by rupture of one or a few tubes are well known design basis events in both, western and VVER NPPs. Operating experience and in-service inspections of VVER-440 units have demonstrated also the potential for large PRISE leaks in the case of the steam generator (SG) primary collector cover lift-up (Rovno NPP). Without performing any countermeasure for limitation of SG collector cover lift-up, a full opening results in PRISE leak with an equivalent diameter 107 mm. Although this accident was not considered in the original design, this event is usually analysed as DBA too. Different means are available for detection and mitigation of PRISE leakage in NPPs currently in operation (J.Bohunice V-1 and V-2) or under construction (Mochovce) in Slovakia. 8 refs.

  13. Practical implementation of a higher order transverse leakage approximation

    International Nuclear Information System (INIS)

    Prinsloo, Rian H.; Tomašević

    2011-01-01

    Transverse integrated nodal diffusion methods currently represent the standard in full core neutronic simulation. The primary shortcoming in this approach, be it via the Analytic Nodal Method or Nodal Expansion Method, is the utilization of the quadratic transverse leakage approximation. This approach, although proven to work well for typical LWR problems, is not consistent with the formulation of nodal methods and can cause accuracy and convergence problems. In this work an improved, consistent quadratic leakage approximation is formulated, which derives from the class of higher order nodal methods developed some years ago. In this new approach, only information relevant to describing the transverse leak- age terms in the zero-order nodal equations are obtained from the higher order formalism. The method yields accuracy comparable to full higher order methods, but does not suffer from the same computational burden which these methods typically incur. (author)

  14. Air leakage test of reactor hall using tracer technique

    International Nuclear Information System (INIS)

    Yang Yanqiu; Yang Liang; Yang Tongzai

    2011-01-01

    The leakage ratios of three related reactor halls were tested by sulfur hexafluoride gaseous tracer technique. Moreover, the accumulation intensities of leak gas and its retention time in some important working rooms, the crossroads of corridors and anteroom of the building were detected. The results show that the air leakage ratios of the three reactor halls are (7.30±0.16) x 10 -4 , (1.88±0.12) x 10 -4 and (2.07±0.07) x 10 -4 h -1 . The leak gas accumulates in all the detected working rooms fast, and the retention time to various rooms is about 5 h. The heaviest intensities are in the clothes change rooms on the first floor. However, the retention time to the crossroads and the anteroom is about 10 h, and the accumulation intensities are much small. (authors)

  15. Extravascular Lung Water and Acute Lung Injury

    Directory of Open Access Journals (Sweden)

    Ritesh Maharaj

    2012-01-01

    Full Text Available Acute lung injury carries a high burden of morbidity and mortality and is characterised by nonhydrostatic pulmonary oedema. The aim of this paper is to highlight the role of accurate quantification of extravascular lung water in diagnosis, management, and prognosis in “acute lung injury” and “acute respiratory distress syndrome”. Several studies have verified the accuracy of both the single and the double transpulmonary thermal indicator techniques. Both experimental and clinical studies were searched in PUBMED using the term “extravascular lung water” and “acute lung injury”. Extravascular lung water measurement offers information not otherwise available by other methods such as chest radiography, arterial blood gas, and chest auscultation at the bedside. Recent data have highlighted the role of extravascular lung water in response to treatment to guide fluid therapy and ventilator strategies. The quantification of extravascular lung water may predict mortality and multiorgan dysfunction. The limitations of the dilution method are also discussed.

  16. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind

    2016-01-01

    BACKGROUND: After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. METHOD: Leakage ...

  17. Some possible causes and probability of leakages in LMFBR steam generators

    International Nuclear Information System (INIS)

    Bolt, P.R.

    1984-01-01

    Relevant operational experience with steam generators for process and conventional plant and thermal and fast reactors is reviewed. Possible causes of water/steam leakages into sodium/gas are identified and data is given on the conditions necessary for failure, leakage probability and type of leakage path. (author)

  18. Cardiac and vascular malformations

    International Nuclear Information System (INIS)

    Ley, S.; Ley-Zaporozhan, J.

    2015-01-01

    Malformations of the heart and great vessels show a high degree of variation. There are numerous variants and defects with only few clinical manifestations and are only detected by chance, such as a persistent left superior vena cava or a partial anomalous pulmonary venous connection. Other cardiovascular malformations are manifested directly after birth and need prompt mostly surgical interventions. At this point in time echocardiography is the diagnostic modality of choice for morphological and functional characterization of malformations. Additional imaging using computed tomography (CT) or magnetic resonance imaging (MRI) is only required in a minority of cases. If so, the small anatomical structures, the physiological tachycardia and tachypnea are a challenge for imaging modalities and strategies. This review article presents the most frequent vascular, cardiac and complex cardiovascular malformations independent of the first line diagnostic imaging modality. (orig.) [de

  19. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  20. CloudSafetyNet: Detecting Data Leakage between Cloud Tenants

    OpenAIRE

    Pietzuch, PR; Priebe, C; Muthukumaran, D; O'Keeffe, D; Eyers, D; Shand, B; Kapitza, R

    2014-01-01

    01.12.14 KB. Ok to add accepted version to spiral. Copyright ? 2014 by the Association for Computing Machinery, Inc. (ACM).When tenants deploy applications under the control of third-party cloud providers, they must trust the providers security mechanisms for inter-tenant isolation, resource sharing and access control. Despite a providers best efforts, accidental data leakage may occur due to misconfigurations or bugs in the cloud platform. Especially in Platform-as-a-Service (PaaS) clouds...

  1. Deforestation, Leakage and Avoided Deforestation Policies: A Spatial Analysis

    OpenAIRE

    Philippe Delacote; Elizabeth J. Z. Robinson; Sébastien Roussel

    2015-01-01

    This paper analyses the impact of several avoided deforestation policies within a patchy forested landscape. Central is the idea that one neighbour's deforestation actions may impact the returns to deforestation in nearby patches. We determine the impact of each policy in terms of avoided deforestation and leakage levels at the landscape scale through modelling and simulations. Avoided deforestation policies at a landscape level are respectively: two Payment for Environmental Services (PES) p...

  2. A code for leakage neutron spectra through thick shields

    International Nuclear Information System (INIS)

    Nagarajan, P.S.; Sethulakshmi, P.; Raghavendran, C.P.

    1975-01-01

    An exponential transform Monte Carlo code has been developed for deep penetration of neutrons and the results of leakage neutron spectra of this code have been compared with those of a basic Monte Carlo code for small thickness. The development of the code and optimisation of certain transform parameters are discussed and results are presented for a few thick shields of concrete and water in the context of neutron monitoring in the environs of accelerator and reactor shields. (author)

  3. The Technique to Prevent the Data Leakage using Covert Channels

    Directory of Open Access Journals (Sweden)

    Anna Vasilievna Arkhangelskaya

    2013-12-01

    Full Text Available The purpose of the article was to analyze technique to prevent information leakage using covert channels. The main steps are as follows: involving covert channels identification, data throughput estimation, its elimination or limitation, audit and detection. Three schemes of identification had been analyzed: shared resources methodology, covert flow tree method, message sequence diagram method. Ways of guarantee information delivery from systems with low security level to systems with high security level have been investigated.

  4. A decision support system for on-line leakage localization

    OpenAIRE

    Meseguer, Jordi; Mirats-Tur, Josep M.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Pérez, Ramon; Sanz, Gerard; Ibarra, David

    2014-01-01

    This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integr...

  5. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  6. Exchange-Rate Unification with Black Market Leakages; Russia 1992

    OpenAIRE

    Linda S. Goldberg

    1993-01-01

    In 1992 Russia unified the multiple exchange rates that had applied to international transactions. This paper describes the multiple exchange rate system that existed in Russia prior to mid-1992 and undertakes a theoretical exploration of the effects of the exchange rate unification that took place in July 1992. The model developed here allows for leakages between official and black markets and permits flexibility of the exchange rates in both official and parallel currency markets. Within th...

  7. Artificial-Crack-Behavior Test Evaluation of the Water-Leakage Repair Materials Used for the Repair of Water-Leakage Cracks in Concrete Structures

    OpenAIRE

    Soo-Yeon Kim; Sang-Keun Oh; Byoungil Kim

    2016-01-01

    There are no existing standard test methods at home and abroad that can verify the performance of water leakage repair materials, and it is thus very difficult to perform quality control checks in the field of water leakage repair. This study determined that the key factors that have the greatest impact on the water leakage repair materials are the micro-behaviors of cracks, and proposed an artificial-crack-behavior test method for the performance verification of the repair materials. The per...

  8. [Lung abscess which needed to be distinguished from lung cancer; report of a case].

    Science.gov (United States)

    Kamiya, Kazunori; Yoshizu, Akira; Misumi, Yuki; Hida, Naoya; Okamoto, Hiroaki; Yoshida, Sachiko

    2011-12-01

    Differential diagnosis of lung abscess from lung cancer is sometimes difficult. In February 2009, a 57-year-old man consulted our hospital complaining of bloody sputum. Chest computed tomography (CT) demonstrated a 2.5 cm nodule with pleural indentation, spicula and vascular involvement in the right S(3). Bronchofiberscope could not establish a definitive diagnosis. Blood test showed no abnormality. Three months later, progression of the nodule to the adjacent middle lobe was demonstrated by follow-up CT, and F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) showed isotope accumulation in the nodule and hilar lymph node. A diagnosis of lung cancer was suspected and surgery was performed. The diagnosis of possible lung cancer was made by needle biopsy, and the patient underwent right upper lobectomy and partial resection of middle lobe with standard nodal dissection. The final pathological diagnosis was lung abscess. Lung abscess must be kept in mind as a possible differential diagnosis when abnormal shadow suspected of lung cancer is observed.

  9. Environmental and artificial tracers for investigating leakages into salt mines

    International Nuclear Information System (INIS)

    Zuber, A.; Grabczak, J.; Kolonko, M.

    1979-01-01

    The paper presents the results of five years of experience in investigating the origin of waters in the Wapno mine, where salt is exploited in a Zechstein dome, in northwestern Poland. Tritium and 14 C measurements showed young infiltration waters in leakages at the third level of the mine. Stable isotope determinations showed a considerable shift of values from the precipitation line, both on activity and on concentration scales. Despite this shift, it was possible to distinguish infiltration waters from connate ones appearing at deeper mine levels. In 1976 and 1977 leakage flow-rates increased and the mineralization decreased. Tritium and 14 C contents did not then change, showing that, at the initial stages of flooding, the origin of water in the leakages was not changed. The first results of isotope investigations in the Klodawa mine, situated in another Zechstein salt dome in central Poland, showed connate waters. Observations performed in the Wieliczka salt mine, situated in Miocene formations in southern Poland, showed old waters originating from the surrounding formations. Their stable isotope composition shows that recharge took place in a cooler climate. The 14 C content of these waters is 1 to 2% of recent carbon. The experimental procedure used to determine the isotopic composition of highly mineralized brines is also described. (author)

  10. Leakage losses from a hydraulic fracture and fracture propagation

    International Nuclear Information System (INIS)

    Johnson, R.E.; Gustafson, C.W.

    1988-01-01

    The fluid mechanics of viscous fluid injection into a fracture embedded in a permeable rock formation is studied. Coupling between flow in the fracture and flow in the rock is retained. The analysis is based on a perturbation scheme that assumes the depth of penetration of the fluid into the rock is small compared to the characteristic length w 3 0 /k, where w 0 is the characteristic crack width and k is the permeability. This restriction, however, is shown to be minor. The spatial dependence of the leakage rate per unit length from the fracture is found to be linear, decreasing from the well bore to the fracture tip where it vanishes. The magnitude of the leakage rate per unit length is found to decay in time as t -1 /sup // 3 if the injection rate at the well bore is constant, and as t -1 /sup // 2 if the well bore pressure is held constant. The results cast considerable doubt on the validity of Carter's well-known leakage formula (Drilling Prod. Prac. API 1957, 261) derived from a one-dimensional theory. Using the simple fracture propagation model made popular by Carter, the present work also predicts that the fracture grows at a rate proportional to t 1 /sup // 3 for a fixed well bore injection rate and a rate proportional to t 1 /sup // 4 for a fixed well bore pressure

  11. Mechanistic approach to the sodium leakage and fire analysis

    International Nuclear Information System (INIS)

    Yamaguchi, Akira; Muramatsu, Toshiharu; Ohira, Hiroaki; Ida, Masao

    1997-04-01

    In December 1995, a thermocouple well was broken and liquid sodium leaked out of the intermediate heat transport system of the prototype fast breeder reactor Monju. In the initiating process of the incident, liquid sodium flowed out through the hollow thermocouple well, nipple and connector. As a result, liquid sodium, following ignition and combustion, was dropping from the connector to colide with the duct and grating placed below. The collision may cause fragmentation and scattering of the sodium droplet that finally was piled up on the floor. This report deals with the development of computer programs for the phenomena based on mechanistics approach. Numerical analyses are also made for fundamental sodium leakage and combustion phenomenon, sodium combustion experiment, and Monju incident condition. The contents of this report is listed below: (1) Analysis of chemical reaction process based on molecular orbital method, (2) Thermalhy draulic analysis of the sodium combustion experiment II performed in 1996 at O-arai Engineering Center, PNC, (3) Thermalhy draulic analysis of room A-446 of Monju reactor when the sodium leakage took place, (4) Direct numerical simulation of sodium droplet, (5) Sodium leakage and scattering analysis using three dimensional particle method, (6) Multi-dimensional combustion analysis and multi-point approximation combustion analysis code. Subsequent to the development work of the programs, they are to be applied to the safety analysis of the Fast Breeder Reactor. (author)

  12. A Minimum Leakage Quasi-Static RAM Bitcell

    Directory of Open Access Journals (Sweden)

    Adam Teman

    2011-05-01

    Full Text Available As SRAMs continue to grow and comprise larger percentages of the area and power consumption in advanced systems, the need to minimize static currents becomes essential. This brief presents a novel 9T Quasi-Static RAM Bitcell that provides aggressive leakage reduction and high write margins. The quasi-static operation method of this cell, based on internal feedback and leakage ratios, minimizes static power while maintaining sufficient, albeit depleted, noise margins. This paper presents the concept of the novel cell, and discusses the stability of the cell under hold, read and write operations. The cell was implemented in a low-power 40 nm TSMC process, showing as much as a 12× reduction in leakage current at typical conditions, as compared to a standard 6T or 8T bitcell at the same supply voltage. The implemented cell showed full functionality under global and local process variations at nominal and low voltages, as low as 300 mV.

  13. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  14. Detection Test for Leakage of CO2 into Sodium Loop

    International Nuclear Information System (INIS)

    Park, Sun Hee; Wi, Myung-Hwan; Min, Jae Hong

    2015-01-01

    This report is about the facility for the detection test for leakage of CO 2 into sodium loop. The facility for the detection test for leakage of CO 2 into sodium loop was introduced. The test will be carried out. Our experimental results are going to be expected to be used for approach methods to detect CO 2 leaking into sodium in heat exchangers. A sodium-and-carbon dioxide (Na-CO 2 ) heat exchanger is one of the key components for the supercritical CO 2 Brayton cycle power conversion system of sodium-cooled fast reactors (SFRs). A printed circuit heat exchanger (PCHE) is considered for the Na-CO 2 heat exchanger, which is known to have potential for reducing the volume occupied by the exchangers compared to traditional shell-and-tube heat exchangers. Among various issues about the Na- CO 2 exchanger, detection of CO 2 leaking into sodium in the heat exchanger is most important thing for its safe operation. It is known that reaction products from sodium and CO 2 such as sodium carbonate (Na 2 CO 3 ) and amorphous carbon are hardly soluble in sodium, which cause plug sodium channels. Detection technique for Na 2 CO 3 in sodium loop has not been developed yet. Therefore, detection of CO 2 and CO from reaction of sodium and CO 2 are proper to detect CO 2 leakage into sodium loop

  15. Method of detecting water leakage in radioactive waste containing vessel

    International Nuclear Information System (INIS)

    Ishioka, Hitoshi; Takao, Yoshiaki; Hayakawa, Kiyoshige.

    1989-01-01

    Lower level radioactive wastes formed upon operation of nuclear facilities are processed by underground storage. In this case, a plurality of drum cans packed with radioactive wastes are contained in a vessel and a water soluble dye material is placed at the inside of the vessel. The method of placing the water soluble dye material at the inside of the vessel includes a method of coating the material on the inner surface of the vessel and a method of mixing the material in sands to be filled between each of the drum cans. Then, leakage of water soluble dye material is detected when water intruding from the outside into the vessel is again leached out of the vessel, to detect the water leakage from the inside of the vessel. In this way, it is possible to find a water-invaded vessel before corrosion of the drum can by water intruded into the vessel and leakage of nuclides in the drum can. Accordingly, it is possible to apply treatment such as repair before occurrence of accident and can maintain the safety of radioactive water processing facilities. (I.S.)

  16. Fail-safe first wall for preclusion of little leakage

    International Nuclear Information System (INIS)

    Shibui, Masanao; Nakahira, Masataka; Tada, Eisuke; Takatsu, Hideyuki

    1994-05-01

    Leakages although excluded by design measures would occur most probably in highly stressed areas, weldments and locations without possibility to classify the state by in-service inspection. In a water-cooled first wall, allowable leak rate of water is generally very small, and therefore, locating of the leak portion under highly activated environment will be very difficult and be time-consuming. The double-wall concept is promising for the ITER first wall, because it can be made fail-safe by the application of the leak-before-break and the multiple load path concepts, and because it has a potential capability to solve the little leak problem. When the fail safe strength is well defined, subcritical crack growth in the damaged wall can be permitted. This will enable to detect stable leakage of coolant without deteriorating plasma operation. The paper deals with the little leak problem and presents method for evaluating small leak rate of a liquid coolant from crack-like defects. The fail-safe first wall with the double-wall concept is also proposed for preclusion of little leakage and its fail-safety is discussed. (author)

  17. Leakage flow simulation in a specific pump model

    International Nuclear Information System (INIS)

    Dupont, P; Bayeul-Lainé, A C; Dazin, A; Bois, G; Roussette, O; Si, Q

    2014-01-01

    This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 8.06 code (RANS frozen and unsteady calculations). Comparisons between numerical and experimental results are presented and discussed for three flow rates. The performances of the diffuser obtained by numerical simulation results are compared to the performances obtained by three-hole probe indications. The comparisons show few influence of fluid leakage on global performances but a real improvement concerning the efficiency of the impeller, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up

  18. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  19. Increased pulmonary vascular permeability as a cause of re-expansion edema in rabbits

    International Nuclear Information System (INIS)

    Pavlin, D.J.; Nessly, M.L.; Cheney, F.W.

    1981-01-01

    In order to study the mechanism(s) underlying re-expansion edema, we measured the concentration of labeled albumin (RISA) in the extravascular, extracellular water (EVECW) of the lung as a measure of pulmonary vascular permeability. Re-expansion edema was first induced by rapid re-expansion of rabbit lungs that had been collapsed for 1 wk by pneumothorax. The RISA in EVECW was expressed as a fraction of its plasma concentration: (RISA)L/(RISA)PL. The volume of EVECW (ml/gm dry lung) was measured using a 24 Na indicator. Results in re-expansion edema were compared with normal control lungs and with oleic acid edema as a model of permeability edema. In re-expanded lungs, EVECW (3.41 +/- SD 1.24 ml/g) and (RISA)L/(RISA)PL 0.84 +/- SD 0.15) were significantly increased when compared with normal control lungs (2.25 +/- 0.41 ml/g and 0.51 +/- 0.20, respectively). Results in oleic acid edema (5.66 +/- 2.23 ml/g and 0.84 +/- 0.23) were similar to re-expansion edema. This suggested that re-expansion edema is due to increased pulmonary vascular permeability caused by mechanical stresses applied to the lung during re-expansion

  20. CIRSE Vascular Closure Device Registry

    NARCIS (Netherlands)

    Reekers, Jim A.; Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2011-01-01

    Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. The CIRSE registry of closure devices

  1. Dynamic adaption of vascular morphology

    DEFF Research Database (Denmark)

    Okkels, Fridolin; Jacobsen, Jens Christian Brings

    2012-01-01

    The structure of vascular networks adapts continuously to meet changes in demand of the surrounding tissue. Most of the known vascular adaptation mechanisms are based on local reactions to local stimuli such as pressure and flow, which in turn reflects influence from the surrounding tissue. Here ...

  2. Diagnostic criteria for vascular dementia

    NARCIS (Netherlands)

    Scheltens, P.; Hijdra, A. H.

    1998-01-01

    The term vascular dementia implies the presence of a clinical syndrome (dementia) caused by, or at least assumed to be caused by, a specific disorder (cerebrovascular disease). In this review, the various sets of criteria used to define vascular dementia are outlined. The various sets of criteria

  3. The vascular secret of Klotho

    DEFF Research Database (Denmark)

    Lewin, Ewa; Olgaard, Klaus

    2015-01-01

    Klotho is an evolutionarily highly conserved protein related to longevity. Increasing evidence of a vascular protecting effect of the Klotho protein has emerged and might be important for future treatments of uremic vascular calcification. It is still disputed whether Klotho is locally expressed ...

  4. Pulsed dye laser application in ablation of vascular ectasias of the larynx: a preliminary animal study

    Science.gov (United States)

    Woo, Peak; Wang, Zhi; Perrault, Donald F., Jr.; McMillan, Kathleen; Pankratov, Michail M.

    1995-05-01

    Vascular ectasias (dilatation) and vascular lesions of the larynx are difficult to treat with exciting modalities. Varix (enlarged vessel) of the vocal folds, vocal fold hemorrhage, vascular polyp, hemangioma, intubation or contact granuloma are common problems which disturb voice. Current applications of CO2 laser and cautery often damage the delicate vocal fold cover. The 585 nm dermatologic pulsed dye laser may be an ideal substitute. Two adult canines were examined under anesthesia via microlaryngoscopy technique. Pulsed dye laser (SPTL-1a, Candela Laser Corp., Wayland, MA) energy was delivered via the micromanipulator with the 3.1-mm spot size in single pulses of 6, 8, and 10 Joules/cm2 and applied to the vessels of the vocal folds, epiglottis, and arytenoid cartilage. Endoscopic examination was carried out immediately after the treatment and at 4 weeks postoperatively. The animals were sacrificed at 3 weeks, larynges excised, and whole organ laryngeal section were prepared for histology. Pulsed dye laser thrombosed vessels of the vocal fold using 6 or 8 Joules/cm2. Vascular break and leakage occurred at 10 Joules/cm2. Follow up examination showed excellent vessel obliteration or thrombosis without scarring or injury to the overlying tissues. Histologic examination shows vascular thrombosis without inflammation and fibrosis in the vocal fold cover. Pulsed dye laser may have promise in treatment of vascular lesions of the larynx and upper airway.

  5. [The association of lung cancer and atheromatous arterial disease].

    Science.gov (United States)

    Lamour, A; Azorin, J; Tchandjou Ngoko, L E; Valeyre, D; Morère, F; Destable, M D; de Saint-Florent, G

    1989-01-01

    This work is based on the retrospective study of the case history of 26 patients who were treated between September 1979 and January 1987 in the department of thoracic and vascular surgery at the Avicenne Hospital--and who were all suffering from both lung cancer and atheromatous arterial disease. It is now well established by all the epidemiologic research that the link between lung cancer and atheromatous arterial disease is smoking tobacco. The risks involved in the misunderstanding of such an association are not without danger for the patient, particularly the risk of severe complication of possible coronary or carotid lesions, threatening survival; from this derives the necessity to decide automatically for a minimum of pre-surgery vascular investigations in the case of patients suffering from lung cancer. The therapeutic strategy in this association must be thorough, considering that there are three priorities in the vascular field which must absolutely be treated before the lung itself: --the coronary and carotid lesions which are likely to be complicated cancer after surgery and any state of emergency in the other vascular territories. The fight against tobacco smoking must also be considered as a priority aim.

  6. Social media in vascular surgery.

    Science.gov (United States)

    Indes, Jeffrey E; Gates, Lindsay; Mitchell, Erica L; Muhs, Bart E

    2013-04-01

    There has been a tremendous growth in the use of social media to expand the visibility of various specialties in medicine. The purpose of this paper is to describe the latest updates on some current applications of social media in the practice of vascular surgery as well as existing limitations of use. This investigation demonstrates that the use of social networking sites appears to have a positive impact on vascular practice, as is evident through the incorporation of this technology at the Cleveland Clinic and by the Society for Vascular Surgery into their approach to patient care and physician communication. Overall, integration of social networking technology has current and future potential to be used to promote goals, patient awareness, recruitment for clinical trials, and professionalism within the specialty of vascular surgery. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  7. Sodium leakage experience at the prototype FBR Monju

    International Nuclear Information System (INIS)

    Miyakawa, A.; Maeda, H.; Kani, Y.; Ito, K.

    2000-01-01

    Monju is Japan's prototype fast breeder reactor: 280 MWe (714 MWt), fueled with mixed oxides of plutonium and uranium, cooled by liquid sodium. Construction was started in 1985 and initial criticality was attained in April 1994. On 8th December 1995, sodium leakage from a secondary circuit occurred in a piping room of the reactor auxiliary building. The secondary sodium leaked through a temperature sensor, due to the breakaway of the tip of the thermocouple well tube installed near the secondary circuit outlet of the intermediate heat exchanger (IHX). The reactor remained cooled and thus, from the viewpoint of radiological hazards, the safety of the reactor was secured. There was no release of radioactive material. There were no adverse effects for personnel and the surrounding environment. The thermocouple well tube failure resulted from high cycle fatigue due to flow induced vibration. It was found that this flow induced vibration was not caused by well-known Von Karman vortex shedding, but a symmetric vortex shedding. The design of the thermocouple well, which was subject to avoid this phenomenon, was reviewed. A new design guide against the flow-induced vibration was prepared by JNC (Japan Nuclear Cycle Development Institute). This is more comprehensive and definitive than the existing guide 'ASME N-1300' (Flow-induced vibration of tube and tube banks). New thermocouple well designs were proposed consistent with this design guide. To prevent a recurrence of the secondary sodium leakage incident, comprehensive design review activities were started for the purpose of checking the safety and reliability of the plant. As a result, several aspects to be improved were identified and improvements and countermeasures have been studied. The main improvements and countermeasures are as follows: To enable the operators to understand and react to incidents quickly, new sodium leakage detectors (TV monitors, smoke sensors) and a new surveillance system will be installed; To

  8. Intersections of lung progenitor cells, lung disease and lung cancer.

    Science.gov (United States)

    Kim, Carla F

    2017-06-30

    The use of stem cell biology approaches to study adult lung progenitor cells and lung cancer has brought a variety of new techniques to the field of lung biology and has elucidated new pathways that may be therapeutic targets in lung cancer. Recent results have begun to identify the ways in which different cell populations interact to regulate progenitor activity, and this has implications for the interventions that are possible in cancer and in a variety of lung diseases. Today's better understanding of the mechanisms that regulate lung progenitor cell self-renewal and differentiation, including understanding how multiple epigenetic factors affect lung injury repair, holds the promise for future better treatments for lung cancer and for optimising the response to therapy in lung cancer. Working between platforms in sophisticated organoid culture techniques, genetically engineered mouse models of injury and cancer, and human cell lines and specimens, lung progenitor cell studies can begin with basic biology, progress to translational research and finally lead to the beginnings of clinical trials. Copyright ©ERS 2017.

  9. Intersections of lung progenitor cells, lung disease and lung cancer

    Directory of Open Access Journals (Sweden)

    Carla F. Kim

    2017-06-01

    Full Text Available The use of stem cell biology approaches to study adult lung progenitor cells and lung cancer has brought a variety of new techniques to the field of lung biology and has elucidated new pathways that may be therapeutic targets in lung cancer. Recent results have begun to identify the ways in which different cell populations interact to regulate progenitor activity, and this has implications for the interventions that are possible in cancer and in a variety of lung diseases. Today's better understanding of the mechanisms that regulate lung progenitor cell self-renewal and differentiation, including understanding how multiple epigenetic factors affect lung injury repair, holds the promise for future better treatments for lung cancer and for optimising the response to therapy in lung cancer. Working between platforms in sophisticated organoid culture techniques, genetically engineered mouse models of injury and cancer, and human cell lines and specimens, lung progenitor cell studies can begin with basic biology, progress to translational research and finally lead to the beginnings of clinical trials.

  10. Lung cancer

    International Nuclear Information System (INIS)

    Kato, Toshio

    1982-01-01

    Based on the own experience and world literatures, contribution of radiation in the treatment of lung cancer was reviewed and discussed. Although the patients with advanced cancer were referred to radiation usually, the results of radiotherapy were superior to those by chemotherapy. Of course the radiotherapy was a local one, radiation combined with chemotherapy was highly recommended, besides systemic administration of chemotherapeutics, special methods such as bronchial arterial infusion (BAI) and chemoembolization would be more favourable in selected patients. Treatment of undifferentiated small cell carcinoma was becoming more dependent on chemotherapy, radiation showed as excellent local control as ever. To treat locally extended cancer patients with involvement of the thoracic wall and Pancoast's syndrome, external radiation alone were not successful, interstitial radiation or a single exposure with a large dose during the thoracotomy would be promising. Finally, data indicated that aged and poor risk patients in early stage of cancer might be treated by radiation instead of unjustifiable operation. (author)

  11. Staging of Lung Cancer

    Science.gov (United States)

    ... LUNG CANCER MINI-SERIES #2 Staging of Lung Cancer Once your lung cancer is diagnosed, staging tells you and your health care provider about ... at it under a microscope. The stages of lung cancer are listed as I, II, III, and IV ...

  12. Lung needle biopsy

    Science.gov (United States)

    ... if you have certain lung diseases such as emphysema. Usually, a collapsed lung after a biopsy does not need treatment. But ... any type Bullae (enlarged alveoli that occur with emphysema) Cor pulmonale (condition ... of the lung High blood pressure in the lung arteries Severe ...

  13. [Detection of marginal leakage of Class V restorations in vitro by micro-CT].

    Science.gov (United States)

    Gu, Lin-juan; Zhao, Xin-yi; Li, Shi-bao

    2012-09-01

    To evaluate the reliability and superiority of micro-CT in marginal leakage assessment of Class V restorations. Class V preparations with gingival margins in dentin and occlusal in enamel were made in sixteen extracted non-carious human molars and restored with dental bonding agents and composite resin. All teeth were then immersed in 50% ammonia-silver nitrate solution for 12 hours, followed by developing solution for 8 hours. Each restoration was scanned by a micro-CT and silver leakage was measured and three-dimensional image of the silver leakage alone cavity wall were reconstructed. Afterward, all restorations were sectioned and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by micro-CT and microscope were compared for equivalency. The silver leakage depths in gingival wall obtained with micro-CT (0.78 mm) and microscope (0.74 mm) showed no significant difference (P > 0.05), while the judgment of leakage depths in occlusal wall in micro-CT image (0.40 mm) was affected by adjacent enamel structure, giving less leakage depths compared to microscope (0.72 mm)(P leakages showed channels on their way to spreading. Micro-CT can detect precisely the silver leakage in the dentin wall of a restoration and display its three-dimensional shape fully. Enamel structure affects the detection of the silver leakage next to it.

  14. IMPACT OF DUCT LEAKAGE PRESSURES ON THE SHAPE OF THE DELTA Q CURVE

    International Nuclear Information System (INIS)

    Andrews, J.W.

    2002-01-01

    The question of whether and to what extent information on the pressures driving duct leaks can be extracted from the data taken during the Delta Q test for duct leakage is investigated. Curves of Delta Q vs. house pressure are generated for sets of cases where the supply and return leakage rates to/from outside are held constant while the leakage pressures are varied. It is found that the Delta Q curve takes on two qualitatively different shapes, one for leakage pressures within the range of house pressures used in the Delta Q test (i.e., -25 Pa to +25 Pa) and the other for leakage pressures well outside this range. These effects are seen in experimental data taken with leakage at known pressures. However, extracting the signal of the leakage pressure from the surrounding noise caused by random measurement variation is likely to be a difficult problem in many cases

  15. Leakage characterization of top select transistor for program disturbance optimization in 3D NAND flash

    Science.gov (United States)

    Zhang, Yu; Jin, Lei; Jiang, Dandan; Zou, Xingqi; Zhao, Zhiguo; Gao, Jing; Zeng, Ming; Zhou, Wenbin; Tang, Zhaoyun; Huo, Zongliang

    2018-03-01

    In order to optimize program disturbance characteristics effectively, a characterization approach that measures top select transistor (TSG) leakage from bit-line is proposed to quantify TSG leakage under program inhibit condition in 3D NAND flash memory. Based on this approach, the effect of Vth modulation of two-cell TSG on leakage is evaluated. By checking the dependence of leakage and corresponding program disturbance on upper and lower TSG Vth, this approach is validated. The optimal Vth pattern with high upper TSG Vth and low lower TSG Vth has been suggested for low leakage current and high boosted channel potential. It is found that upper TSG plays dominant role in preventing drain induced barrier lowering (DIBL) leakage from boosted channel to bit-line, while lower TSG assists to further suppress TSG leakage by providing smooth potential drop from dummy WL to edge of TSG, consequently suppressing trap assisted band-to-band tunneling current (BTBT) between dummy WL and TSG.

  16. A coupled approach for the three-dimensional simulation of pipe leakage in variably saturated soil

    Science.gov (United States)

    Peche, Aaron; Graf, Thomas; Fuchs, Lothar; Neuweiler, Insa

    2017-12-01

    In urban water pipe networks, pipe leakage may lead to subsurface contamination or to reduced waste water treatment efficiency. The quantification of pipe leakage is challenging due to inaccessibility and unknown hydraulic properties of the soil. A novel physically-based model for three-dimensional numerical simulation of pipe leakage in variably saturated soil is presented. We describe the newly implemented coupling between the pipe flow simulator HYSTEM-EXTRAN and the groundwater flow simulator OpenGeoSys and its validation. We further describe a novel upscaling of leakage using transfer functions derived from numerical simulations. This upscaling enables the simulation of numerous pipe defects with the benefit of reduced computation times. Finally, we investigate the response of leakage to different time-dependent pipe flow events and conclude that larger pipe flow volume and duration lead to larger leakage while the peak position in time has a small effect on leakage.

  17. Automated detection of leakage in fluorescein angiography images with application to malarial retinopathy.

    Science.gov (United States)

    Zhao, Yitian; MacCormick, Ian J C; Parry, David G; Leach, Sophie; Beare, Nicholas A V; Harding, Simon P; Zheng, Yalin

    2015-06-01

    The detection and assessment of leakage in retinal fluorescein angiogram images is important for the management of a wide range of retinal diseases. We have developed a framework that can automatically detect three types of leakage (large focal, punctate focal, and vessel segment leakage) and validated it on images from patients with malarial retinopathy. This framework comprises three steps: vessel segmentation, saliency feature generation and leakage detection. We tested the effectiveness of this framework by applying it to images from 20 patients with large focal leak, 10 patients with punctate focal leak, and 5,846 vessel segments from 10 patients with vessel leakage. The sensitivity in detecting large focal, punctate focal and vessel segment leakage are 95%, 82% and 81%, respectively, when compared to manual annotation by expert human observers. Our framework has the potential to become a powerful new tool for studying malarial retinopathy, and other conditions involving retinal leakage.

  18. Vascular disease in cocaine addiction.

    Science.gov (United States)

    Bachi, Keren; Mani, Venkatesh; Jeyachandran, Devi; Fayad, Zahi A; Goldstein, Rita Z; Alia-Klein, Nelly

    2017-07-01

    Cocaine, a powerful vasoconstrictor, induces immune responses including cytokine elevations. Chronic cocaine use is associated with functional brain impairments potentially mediated by vascular pathology. Although the Crack-Cocaine epidemic has declined, its vascular consequences are increasingly becoming evident among individuals with cocaine use disorder of that period, now aging. Paradoxically, during the period when prevention efforts could make a difference, this population receives psychosocial treatment at best. We review major postmortem and in vitro studies documenting cocaine-induced vascular toxicity. PubMed and Academic Search Complete were used with relevant terms. Findings consist of the major mechanisms of cocaine-induced vasoconstriction, endothelial dysfunction, and accelerated atherosclerosis, emphasizing acute, chronic, and secondary effects of cocaine. The etiology underlying cocaine's acute and chronic vascular effects is multifactorial, spanning hypertension, impaired homeostasis and platelet function, thrombosis, thromboembolism, and alterations in blood flow. Early detection of vascular disease in cocaine addiction by multimodality imaging is discussed. Treatment may be similar to indications in patients with traditional risk-factors, with few exceptions such as enhanced supportive care and use of benzodiazepines and phentolamine for sedation, and avoiding β-blockers. Given the vascular toxicity cocaine induces, further compounded by smoking and alcohol comorbidity, and interacting with aging of the crack generation, there is a public health imperative to identify pre-symptomatic markers of vascular impairments in cocaine addiction and employ preventive treatment to reduce silent disease progression. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. [The future of vascular medicine].

    Science.gov (United States)

    Kroeger, K; Luther, B

    2014-10-01

    In the future vascular medicine will still have a great impact on health of people. It should be noted that the aging of the population does not lead to a dramatic increase in patient numbers, but will be associated with a changing spectrum of co-morbidities. In addition, vascular medical research has to include the intensive care special features of vascular patients, the involvement of vascular medicine in a holistic concept of fast-track surgery, a geriatric-oriented intensive monitoring and early geriatric rehabilitation. For the future acceptance of vascular medicine as a separate subject area under delimitation of cardiology and radiology is important. On the other hand, the subject is so complex and will become more complex in future specialisations that mixing of surgery and angiology is desirable, with the aim to preserve the vascular surgical knowledge and skills on par with the medical and interventional measures and further develop them. Only large, interdisciplinary guided vascular centres will be able to provide timely diagnosis and therapy, to deal with the growing multi-morbidity of the patient, to perform complex therapies even in an acute emergency and due to sufficient number of cases to present with well-trained and experienced teams. These requirements are mandatory to decrease patients' mortality step by step. Georg Thieme Verlag KG Stuttgart · New York.

  20. Contemporary vascular smartphone medical applications.

    Science.gov (United States)

    Carter, Thomas; O'Neill, Stephen; Johns, Neil; Brady, Richard R W

    2013-08-01

    Use of smartphones and medical mHealth applications (apps) within the clinical environment provides a potential means for delivering elements of vascular care. This article reviews the contemporary availability of apps specifically themed to major vascular diseases and the opportunities and concerns regarding their integration into practice. Smartphone apps relating to major vascular diseases were identified from the app stores for the 6 most popular smartphone platforms, including iPhone, Android, Blackberry, Nokia, Windows, and Samsung. Search terms included peripheral artery (arterial) disease, varicose veins, aortic aneurysm, carotid artery disease, amputation, ulcers, hyperhydrosis, thoracic outlet syndrome, vascular malformation, and lymphatic disorders. Forty-nine vascular-themed apps were identified. Sixteen (33%) were free of charge. Fifteen apps (31%) had customer satisfaction ratings, but only 3 (6%) had greater than 100. Only 13 apps (27%) had documented medical professional involvement in their design or content. The integration of apps into the delivery of care has the potential to benefit vascular health care workers and patients. However, high-quality apps designed by clinicians with vascular expertise are currently lacking and represent an area of concern in the mHealth market. Improvement in the quality and reliability of these apps will require the development of robust regulation. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario

    Directory of Open Access Journals (Sweden)

    Jing Ma

    2017-11-01

    Full Text Available The technology of carbon dioxide (CO2 capture and storage (CCS has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO2 geological storage was designed to investigate the short-term effects of different CO2 leakage concentration (from 400 g m−2 day−1 to 2,000 g m−2 day−1 on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO2 concentrations. Increasing CO2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 (p < 0.05. Nitrate nitrogen content varied from 1.01 to 4.03 mg/Kg, while Olsen-phosphorus and total phosphorus demonstrated less regular downtrends. The fluorescein diacetate (FDA hydrolytic enzyme activity was inhibited by the increasing CO2 flux, with the average content varying from 22.69 to 11.25 mg/(Kg h (p < 0.05. However, the increasing activity amplitude of the polyphenol oxidase enzyme approached 230%, while the urease activity presented a similar rising trend. Alpha diversity results showed that the Shannon index decreased from 7.66 ± 0.13 to 5.23 ± 0.35 as the soil CO2 concentration increased. The dominant phylum in the soil samples was Proteobacteria, whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% (p < 0.01. Moreover, the abundances of genera Methylophilus, Methylobacillus, and Methylovorus increased, while GP4, GP6 and GP7 decreased. Canonical correlation analysis

  2. Constructal vascularized structures

    Science.gov (United States)

    Cetkin, Erdal

    2015-06-01

    Smart features such as self-healing and selfcooling require bathing the entire volume with a coolant or/and healing agent. Bathing the entire volume is an example of point to area (or volume) flows. Point to area flows cover all the distributing and collecting kinds of flows, i.e. inhaling and exhaling, mining, river deltas, energy distribution, distribution of products on the landscape and so on. The flow resistances of a point to area flow can be decreased by changing the design with the guidance of the constructal law, which is the law of the design evolution in time. In this paper, how the flow resistances (heat, fluid and stress) can be decreased by using the constructal law is shown with examples. First, the validity of two assumptions is surveyed: using temperature independent Hess-Murray rule and using constant diameter ducts where the duct discharges fluid along its edge. Then, point to area types of flows are explained by illustrating the results of two examples: fluid networks and heating an area. Last, how the structures should be vascularized for cooling and mechanical strength is documented. This paper shows that flow resistances can be decreased by morphing the shape freely without any restrictions or generic algorithms.

  3. Bacterial lung abscess

    International Nuclear Information System (INIS)

    Groskin, S.A.; Panicek, D.M.; Ewing, D.K.; Rivera, F.; Math, K.; Teixeira, J.; Heitzman, E.R.

    1987-01-01

    A retrospective review of patients with bacterial lung abscess was carried out. Demographic, clinical, and radiographical features of this patient group are compared with similar data from patients with empyema and/or cavitated lung carcinoma; differential diagnostic points are stressed. The entity of radiographically occult lung abscess is discussed. Complications associated with bacterial lung abscess are discussed. Current therapeutic options and treatment philosophy for patients with bacterial lung abscess are noted

  4. When does the lung die? Kfc, cell viability, and adenine nucleotide changes in the circulation-arrested rat lung.

    Science.gov (United States)

    Jones, D R; Becker, R M; Hoffmann, S C; Lemasters, J J; Egan, T M

    1997-07-01

    Lungs harvested from cadaveric circulation-arrested donors may increase the donor pool for lung transplantation. To determine the degree and time course of ischemia-reperfusion injury, we evaluated the effect of O2 ventilation on capillary permeability [capillary filtration coefficient (Kfc)], cell viability, and total adenine nucleotide (TAN) levels in in situ circulation-arrested rat lungs. Kfc increased with increasing postmortem ischemic time (r = 0.88). Lungs ventilated with O2 1 h postmortem had similar Kfc and wet-to-dry ratios as controls. Nonventilated lungs had threefold (P Kfc at 30 and 60 min postmortem compared with controls. Cell viability decreased in all groups except for 30-min postmortem O2-ventilated lungs. TAN levels decreased with increasing ischemic time, particularly in nonventilated lungs. Loss of adenine nucleotides correlated with increasing Kfc values (r = 0.76). This study indicates that lungs retrieved 1 h postmortem may have normal Kfc with preharvest O2 ventilation. The relationship between Kfc and TAN suggests that vascular permeability may be related to lung TAN levels.

  5. Lung Cancer—Patient Version

    Science.gov (United States)

    The two main types of lung cancer are non-small cell lung cancer and small cell lung cancer. Smoking causes most lung cancers, but nonsmokers can also develop lung cancer. Start here to find information on lung cancer treatment, causes and prevention, screening, research, and statistics on lung cancer.

  6. Numerical investigation of the leakage behaviour of reinforced concrete walls

    International Nuclear Information System (INIS)

    Christoph Niklasch; Laurent Coudert; Gregory Heinfling; Chantal Hervouet; Benoit Masson; Nico Herrmann; Lothar Stempniewski

    2005-01-01

    Full text of publication follows: For the verification of nuclear power plant safety, the leakage behaviour of the containment walls is of decisive importance. Extreme temperatures well over the water boiling temperature accompanied by high internal pressures can occur during an severe accident. In case of cracks through the entire thickness of the containment wall, an air-steam-water mixture may be released. In order to improve the knowledge of the leakage behaviour through cracks during such abnormal occurrences an experimental setup was developed at IfMB and several tests with different parameters were performed. The details of the experimental facility and the performed tests will be described in a separate paper. To improve the understanding of the behaviour of the tested wall elements during the tests numerical simulations of the performed leakage experiments are necessary. Reliable numerical tools provide a basis for the transfer of the leakage behaviour from the tested specimens to the behaviour of whole containment structures. To address the task of developing tools for the numerical simulation of the leakage behaviour of reinforced containment structures, EDF and IfMB decided to cooperate. During this cooperation two different numerical approaches had been made basing on existing tools and models of EDF and IfMB. In the following sections a short overview about the two different models will be given. For the numerical investigation of the leakage phenomena IfMB used the commercial Finite-Element- Program ADINA with ADINA's capability to solve coupled fluid-structure-interaction (FSI) problems. For the investigation of the moving of the specimen and the change of the crack profiles during the tests, it is important to take into account the heating of the specimen by the fluid flowing through the cracks. This is done by an iterative calculation of the fluid model and the structural model of the specimen. The thermo-dynamic boundary conditions representing

  7. Simulations of hydraulic fracturing and leakage in sedimentary basins

    Energy Technology Data Exchange (ETDEWEB)

    Lothe, Ane Elisabeth

    2004-01-01

    Hydraulic fracturing and leakage of water through the caprock is described from sedimentary basin over geological time scale. Abnormal pressure accumulations reduce the effective stresses in the underground and trigger the initiation of hydraulic fractures. The major faults in the basin define these pressure compartments. In this Thesis, basin simulations of hydraulic fracturing and leakage have been carried out. A simulator (Pressim) is used to calculate pressure generation and dissipitation between the compartments. The flux between the compartments and not the flow within the compartments is modelled. The Griffith-Coulomb failure criterion determines initial failure at the top structures of overpressured compartments, whereas the frictional sliding criterion is used for reactivation along the same fractures. The minimum horizontal stress is determined from different formulas, and an empirical one seems to give good results compared to measured pressures and minimum horizontal stresses. Simulations have been carried out on two datasets; one covering the Halten Terrace area and one the Tune Field area in the northern North Sea. The timing of hydraulic fracturing and amount of leakage has been quantified in the studies from the Halten Terrace area. This is mainly controlled by the lateral fluid flow and the permeability of the major faults in the basin. Low fault permeability gives early failure, while high fault permeabilities results in no or late hydraulic fracturing and leakage from overpressured parts of the basin. In addition to varying the transmissibility of all faults in a basin, the transmissibility across individual faults can be varied. Increasing the transmissibility across faults is of major importance in overpressured to intermediately pressured areas. However, to obtain change in the flow, a certain pressure difference has to be the situation between the different compartments. The coefficient of internal friction and the coefficient of frictional

  8. Air-steam leakage through cracks in concrete

    International Nuclear Information System (INIS)

    Georges Nahas; Helene Simon

    2005-01-01

    Full text of publication follows: In the context of a severe accident in a Pressurised Water nuclear plant, the evaluation of the leakage rate through the containment wall remains a key point of the safety analysis, because it influences directly the consequences on the environment. During a severe accident, large amounts of steam could be released in the containment; internal pressure could rise beyond design limits causing cracks to appear in the internal concrete wall of the double-wall containment and fission products to leak towards the containment annulus. A research program led by the French Institute for Radiological Protection and Nuclear Safety aims to estimate this leakage. In the presence of cracks, most of the leak flows through them. Hence, a first phase of the program was to build a two-phase homogeneous model for the flow of an air-steam mixture through a idealized traversing crack, taking into account condensation phenomena, and considering crack openings from 25 μm to several hundred μm. A numerical model for the flow, coupled with heat transfer in the wall, was implemented in the Finite Element code CAST3M. This model was validated on a small scaled experiment which was made of two parallel glass plates. Comparison of the numerical and experimental results in this 'channel case' has shown good results for the total mass flow rate for channel openings greater than 100 μm. For the 50 μm opening the calculation gave a 50 % estimate of the experimental total mass flow rate. The second phase of the program is now to validate the model on cracks performed in a concrete specimen. In order to do so, we have simulated the experiment VK2/2 described in the article named 'Investigation of the leakage behavior of reinforced concrete walls' by N. Herrmann, C. Niklasch, M. Stegemann, L. Stempniewski. The reinforced concrete slab, 2.7 m long in the reinforcement direction and 1.2 m thick in the cracking direction, is placed in a mechanical set-up and an

  9. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  10. POWER BEAMING LEAKAGE RADIATION AS A SETI OBSERVABLE

    Energy Technology Data Exchange (ETDEWEB)

    Benford, James N. [Microwave Sciences, 1041 Los Arabis Lane, Lafayette, CA 94549 (United States); Benford, Dominic J., E-mail: jimbenford@gmail.com [NASA’s Goddard Space Flight Center, Observational Cosmology Laboratory, Greenbelt, MD 20771 (United States)

    2016-07-10

    The most observable leakage radiation from an advanced civilization may well be from the use of power beaming to transfer energy and accelerate spacecraft. Applications suggested for power beaming involve launching spacecraft to orbit, raising satellites to a higher orbit, and interplanetary concepts involving space-to-space transfers of cargo or passengers. We also quantify beam-driven launch to the outer solar system, interstellar precursors, and ultimately starships. We estimate the principal observable parameters of power beaming leakage. Extraterrestrial civilizations would know their power beams could be observed, and so could put a message on the power beam and broadcast it for our receipt at little additional energy or cost. By observing leakage from power beams we may find a message embedded on the beam. Recent observations of the anomalous star KIC 8462852 by the Allen Telescope Array (ATA) set some limits on extraterrestrial power beaming in that system. We show that most power beaming applications commensurate with those suggested for our solar system would be detectable if using the frequency range monitored by the ATA, and so the lack of detection is a meaningful, if modest, constraint on extraterrestrial power beaming in that system. Until more extensive observations are made, the limited observation time and frequency coverage are not sufficiently broad in frequency and duration to produce firm conclusions. Such beams would be visible over large interstellar distances. This implies a new approach to the SETI search: instead of focusing on narrowband beacon transmissions generated by another civilization, look for more powerful beams with much wider bandwidth. This requires a new approach for their discovery by telescopes on Earth. Further studies of power beaming applications should be performed, potentially broadening the parameter space of the observable features that we have discussed here.

  11. Study of lung perfusion in colagenosis

    International Nuclear Information System (INIS)

    Macedo de Carvalho, A.C.; Calegaro, J.U.M.

    1982-01-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized. (author) [es

  12. Understanding the mechanisms of lung mechanical stress

    Directory of Open Access Journals (Sweden)

    C.S.N.B. Garcia

    2006-06-01

    Full Text Available Physical forces affect both the function and phenotype of cells in the lung. Bronchial, alveolar, and other parenchymal cells, as well as fibroblasts and macrophages, are normally subjected to a variety of passive and active mechanical forces associated with lung inflation and vascular perfusion as a result of the dynamic nature of lung function. These forces include changes in stress (force per unit area or strain (any forced change in length in relation to the initial length and shear stress (the stress component parallel to a given surface. The responses of cells to mechanical forces are the result of the cell's ability to sense and transduce these stimuli into intracellular signaling pathways able to communicate the information to its interior. This review will focus on the modulation of intracellular pathways by lung mechanical forces and the intercellular signaling. A better understanding of the mechanisms by which lung cells transduce physical forces into biochemical and biological signals is of key importance for identifying targets for the treatment and prevention of physical force-related disorders.

  13. Study of lung perfusion in colagenosis

    Energy Technology Data Exchange (ETDEWEB)

    Macedo de Carvalho, A C; Calegaro, J U.M. [Fundacao Hospitalar do Distrito Federal, Distrito Federal (Brazil). Unidade de Medicina Nuclear

    1982-07-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized.

  14. Failure/leakage predictions of concrete structures containing cracks

    International Nuclear Information System (INIS)

    Pan, Y.C.; Marchertas, A.H.; Kennedy, J.M.

    1984-06-01

    An approach is presented for studying the cracking and radioactive release of a reactor containment during severe accidents and extreme environments. The cracking of concrete is modeled as the blunt crack. The initiation and propagation of a crack are determined by using the maximum strength and the J-integral criteria. Furthermore, the extent of cracking is related to the leakage calculation by using a model developed by Rizkalla, Lau and Simmonds. Numerical examples are given for a three-point bending problem and a hypothetical case of a concrete containment structure subjected to high internal pressure during an accident

  15. Large Epiphrenic Diverticulum with Perforation and Leakage below the Diaphragm

    DEFF Research Database (Denmark)

    Brønserud, Majken Munk; Brenøe, Anne-Sofie; Eckardt, Jens

    2015-01-01

    contrast revealed contrast leakage near the minor curvature of the stomach. The following esophagogastroduodenoscopy demonstrated a giant dilatation of the esophagus, as well as a second esophageal lumen originating 25 cm from the incisors. The “false” lumen of the esophagus was located parallel...... to esophagus, ending blindly in a perforation below the diaphragm. The clinical presentation and the patient’s age make it most likely, that it was a long epiphrenic diverticulum of pulsion type. The patient was treated conservatively, discharged after 10 days and has been followed in our outpatient clinic...... for 8 months, until he died of aggressive pulmonary cancer....

  16. Pressure control for minimizing leakage in water distribution systems

    OpenAIRE

    Nourhan Samir; Rawya Kansoh; Walid Elbarki; Amr Fleifle

    2017-01-01

    In the last decades water resources availability has been a major issue on the international agenda. In a situation of worsening scarcity of water resources and the rapidly increasing of water demands, the state of water losses management is part of manâs survival on earth. Leakage in water supply networks makes up a significant amount, sometimes more than 70% of the total water losses. The best practices suggest that pressure management is one of the most effective way to reduce the amount o...

  17. Distributed fiber optic system for oil pipeline leakage detection

    Science.gov (United States)

    Paranjape, R.; Liu, N.; Rumple, C.; Hara, Elmer H.

    2003-02-01

    We present a novel approach for the detection of leakage in oil pipelines using methods of fiber optic distributed sensors, a presence-of-oil based actuator, and Optical Time Domain Reflectometry (OTDR). While the basic concepts of our approach are well understood, the integration of the components into a complete system is a real world engineering design problem. Our focus has been on the development of the actuator design and testing using installed dark fiber. Initial results are promising, however environmental studies into the long term effects of exposure to the environment are still pending.

  18. Lightweight space radiator with leakage control by internal electrostatic fields

    International Nuclear Information System (INIS)

    Kim, H.; Bankoff, S.G.; Miksis, M.J.

    1991-01-01

    An electrostatic liquid film space radiator is proposed. This will employ an internal electrostatic field to prevent leakage of the liquid-metal coolant out of a puncture. This overcomes the major disadvantage of membrane radiators, which is their vulnerability to micrometeorite impacts. Calculations show that leaks of liquid lithium at 700 degree K can easily be stopped from punctures which are several mm in diameter, with very large safety factors. The basic idea lends itself to a variety of radiator concepts, both rotating and non-rotating. Some typical film thickness and pressure calculations in the presence of an electric field are shown

  19. Threats of Password Pattern Leakage Using Smartwatch Motion Recognition Sensors

    Directory of Open Access Journals (Sweden)

    Jihun Kim

    2017-06-01

    Full Text Available Thanks to the development of Internet of Things (IoT technologies, wearable markets have been growing rapidly. Smartwatches can be said to be the most representative product in wearable markets, and involve various hardware technologies in order to overcome the limitations of small hardware. Motion recognition sensors are a representative example of those hardware technologies. However, smartwatches and motion recognition sensors that can be worn by users may pose security threats of password pattern leakage. In the present paper, passwords are inferred through experiments to obtain password patterns inputted by users using motion recognition sensors, and verification of the results and the accuracy of the results is shown.

  20. [Endoscopic endonasal detection of cerebrospinal fluid leakage with topical fluorescein].

    Science.gov (United States)

    Sato, Taku; Kishida, Yugo; Watanabe, Tadashi; Tani, Akiko; Tada, Yasuhiro; Tamura, Takamitsu; Ichikawa, Masahiro; Sakuma, Jun; Omori, Koichi; Saito, Kiyoshi

    2013-08-01

    We evaluated the effectiveness of intraoperative topical application of fluorescein to detect the leakage point of cerebrospinal fluid(CSF)rhinorrhea. Three patients with CSF rhinorrhea were treated with an endoscopic endonasal technique. Ten percent fluorescein was topically used for intraoperative localization of the leak site. A change of the fluorescein color from brown to green due to dilation of CSF were recognized as evidence of CSF rhinorrhea. We repeated the procedure to detect any small defects. All CSF rhinorrheas were successfully repaired by this endoscopic endonasal approach. Topical application of fluorescein is simple and sensitive for identifying intraoperative CSF rhinorrhea.

  1. Early localization of containment leakage during an accident

    International Nuclear Information System (INIS)

    Pepin, P.; Chauliac, C.; Libmann, M.; Martinez, J.M.

    1990-01-01

    In case of an accident in a nuclear plant, checking the containment leaktightness would be a fundamental step for the diagnosis and prognosis of the radiological consequences. Significant help in this task can be provided by softwares. For that purpose, the French Atomic Energy Commission (CEA) is developing an expert system which can provide early in the accident a classification of the possible leakage paths and help understanding the necessary corrections which have to be undertaken by the utility. This software will be used at the Emergency Technical Center of the CEA. Its basic principles are described in this paper

  2. Diabetes and Retinal Vascular Dysfunction

    Directory of Open Access Journals (Sweden)

    Eui Seok Shin

    2014-01-01

    Full Text Available Diabetes predominantly affects the microvascular circulation of the retina resulting in a range of structural changes unique to this tissue. These changes ultimately lead to altered permeability, hyperproliferation of endothelial cells and edema, and abnormal vascularization of the retina with resulting loss of vision. Enhanced production of inflammatory mediators and oxidative stress are primary insults with significant contribution to the pathogenesis of diabetic retinopathy (DR. We have determined the identity of the retinal vascular cells affected by hyperglycemia, and have delineated the cell autonomous impact of high glucose on function of these cells. We discuss some of the high glucose specific changes in retinal vascular cells and their contribution to retinal vascular dysfunction. This knowledge provides novel insight into the molecular and cellular defects contributing to the development and progression of diabetic retinopathy, and will aid in the development of innovative, as well as target specific therapeutic approaches for prevention and treatment of DR.

  3. Artificial-Crack-Behavior Test Evaluation of the Water-Leakage Repair Materials Used for the Repair of Water-Leakage Cracks in Concrete Structures

    Directory of Open Access Journals (Sweden)

    Soo-Yeon Kim

    2016-09-01

    Full Text Available There are no existing standard test methods at home and abroad that can verify the performance of water leakage repair materials, and it is thus very difficult to perform quality control checks in the field of water leakage repair. This study determined that the key factors that have the greatest impact on the water leakage repair materials are the micro-behaviors of cracks, and proposed an artificial-crack-behavior test method for the performance verification of the repair materials. The performance of the 15 kinds of repair materials that are currently being used in the field of water leakage repair was evaluated by applying the proposed test method. The main aim of such a test method is to determine if there is water leakage by injecting water leakage repair materials into a crack behavior test specimen with an artificial 5-mm crack width, applying a 2.5 mm vertical behavior load at 100 cycles, and applying 0.3 N/mm2 constant water pressure. The test results showed that of the 15 kinds of repair materials, only two effectively sealed the crack and thus stopped the water leakage. The findings of this study confirmed the effectiveness of the proposed artificial-crack-behavior test method and suggest that it can be used as a performance verification method for checking the responsiveness of the repair materials being used in the field of water leakage repair to the repetitive water leakage behaviors that occur in concrete structures. The study findings further suggest that the use of the proposed test method makes it possible to quantify the water leakage repair quality control in the field.

  4. Vascular graft infections with Mycoplasma

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Skov Jensen, J; Prag, J

    1995-01-01

    laboratory techniques, the percentage of culture-negative yet grossly infected vascular grafts seems to be increasing and is not adequately explained by the prior use of antibiotics. We have recently reported the first case of aortic graft infection with Mycoplasma. We therefore suggest the hypothesis...... that the large number of culture-negative yet grossly infected vascular grafts may be due to Mycoplasma infection not detected with conventional laboratory technique....

  5. Limb vascular function in women

    DEFF Research Database (Denmark)

    Hellsten, Ylva; Gliemann, Lasse

    2018-01-01

    Throughout life, women are subjected to both acute fluctuations in sex hormones, associated with the menstrual cycle, and chronic changes following the onset of menopause. Female sex hormones, and in particular estrogen, strongly influence cardiovascular function such as the regulation of vascular...... studies. Physical activity should be recommended for women of all ages, but the most essential timing for maintenance of vascular health may be from menopause and onwards....

  6. Facial vascular malformations in children

    International Nuclear Information System (INIS)

    Brunelle, F.O.; Lallemand, D.; Chaumont, P.; Teillac, D.; Manach, Y.

    1988-01-01

    The authors present their experience with conventional and digital angiography of vascular malformations of the head and neck in children. 22 hemangioendotheliomas, 8 venous angiomas, and 3 arteriovenous fistula were studied. 22 patients were embolised. DSA offers many advantages during the diagnostic as well as during the therapeutic phase of angiography. Embolization appears to have a major role in treatment of such vascular malformations. (orig.)

  7. Noninvasive measurement of lung carbon-11-serotonin extraction in man

    International Nuclear Information System (INIS)

    Coates, G.; Firnau, G.; Meyer, G.J.; Gratz, K.F.

    1991-01-01

    The fraction of serotonin extracted on a single passage through the lungs is being used as an early indicator of lung endothelial damage but the existing techniques require multiple arterial blood samples. We have developed a noninvasive technique to measure lung serotonin uptake in man. We utilized the double indicator diffusion principle, a positron camera, 11 C-serotonin as the substrate, and 11 CO-erythrocytes as the vascular marker. From regions of interest around each lung, we recorded time-activity curves in 0.5-sec frames for 30 sec after a bolus injection of first the vascular marker 11 CO-erythrocytes and 10 min later 11 C-serotonin. A second uptake measurement was made after imipramine 25-35 mg was infused intravenously. In three normal volunteers, the single-pass uptake of 11 C-serotonin was 63.9% +/- 3.6%. This decreased in all subjects to a mean of 53.6% +/- 1.4% after imipramine. The rate of lung washout of 11 C was also significantly prolonged after imipramine. This noninvasive technique can be used to measure lung serotonin uptake to detect early changes in a variety of conditions that alter the integrity of the pulmonary endothelium

  8. Studies of axial-leakage simulations for homogeneous and heterogeneous EBR-II core configurations

    International Nuclear Information System (INIS)

    Grimm, K.N.; Meneghetti, D.

    1985-08-01

    When calculations of flux are done in less than three dimensions, leakage-absorption cross sections are normally used to model leakages (flows) in the dimensions for which the flux is not calculated. Since the neutron flux is axially dependent, the leakages, and hence the leakage-absorption cross sections, are also axially dependent. Therefore, to obtain axial flux profiles (or reaction rates) for individual subassemblies, an XY-geometry calculation delineating each subassembly has to be done at several axial heights with space- and energy-dependent leakage-absorption cross sections that are appropriate for each height. This report discusses homogeneous and heterogeneous XY-geometry calculations at various axial locations and using several differing assumptions for the calculation of the leakage-absorption cross section. The positive (outward) leakage-absorption cross sections are modeled as actual leakage absorptions, but the negative (inward) leakage-absorption cross sections are modeled as either negative leakage absorptions (+-B 2 method) or positive downscatter cross sections [the Σ/sub s/(1 → g) method]. 3 refs., 52 figs., 10 tabs

  9. Application Of The Climafor Baseline To Determine Leakage: TheCase Of Scolel Te.

    Energy Technology Data Exchange (ETDEWEB)

    De Jong, B.H.J.; Bazan, E. Esquivel; Quechulpa Montalvo, S.

    2007-06-01

    The acceptance of forestry-based project activities tomitigate greenhouse gases emissions has been subjected to a number ofmethodological questions to be answered, of which the most challengingare baseline establishment and identification of and measuring leakage.Here we pose hypotheses for and quantify leakage of the Scolel Te projectin Chiapas, Mexico. In this project small-scale farmers are implementingforestry, agroforestry, and forest conservation activities, with carbonsequestration as one of the goals. The main leakage monitoring domain isdefined as the area owned by the participating farmers or communitiesoutside the area where the specific project activities take place. Thenull-hypothesis (no leakage) is that non-project land owned by the farmeror community will experience the same carbon stock changes as predictedby the regional baseline, specifically developed for the project. Firstwe assessed the most likely causes and sources of leakage that may occurin the project. From this analysis, one type of leakage seems to beimportant, i.e., activity shifting. Second we estimated the leakage of asample of participating farmers and communities. Actual land use was thencompared with expected land use derived from the baseline. The Plan Vivoof each participant, complemented with readily available tools toidentify the main sources and drivers of leakage are used to developsimple leakage assessment procedures, as demonstrated in this paper.Negative leakage was estimated to be negligible in this study.Incorporating these procedures already in the project planning stage willreduce the uncertainties related to the actual carbon mitigationpotential of any forestry project.

  10. Angiogenesis, Cancer, and Vascular Aging

    Directory of Open Access Journals (Sweden)

    Junji Moriya

    2017-10-01

    Full Text Available Several lines of evidence have revealed that the angiogenic response to ischemic injury declines with age, which might account for the increased morbidity and mortality of cardiovascular disease (CVD among the elderly. While impairment of angiogenesis with aging leads to delayed wound healing or exacerbation of atherosclerotic ischemic diseases, it also inhibits the progression of cancer. Age-related changes of angiogenesis have been considered to at least partly result from vascular aging or endothelial cell senescence. There is considerable evidence supporting the hypothesis that vascular cell senescence contributes to the pathogenesis of age-related CVD, suggesting that vascular aging could be an important therapeutic target. Since therapeutic angiogenesis is now regarded as a promising concept for patients with ischemic CVD, it has become even more important to understand the detailed molecular mechanisms underlying impairment of angiogenesis in older patients. To improve the usefulness of therapeutic angiogenesis, approaches are needed that can compensate for impaired angiogenic capacity in the elderly while not promoting the development or progression of malignancy. In this review, we briefly outline the mechanisms of angiogenesis and vascular aging, followed by a description of how vascular aging leads to impairment of angiogenesis. We also examine potential therapeutic approaches that could enhance angiogenesis and/or vascular function in the elderly, as well as discussing the possibility of anti-senescence therapy or reversal of endothelial cell senescence.

  11. Lung growth and development.

    Science.gov (United States)

    Joshi, Suchita; Kotecha, Sailesh

    2007-12-01

    Human lung growth starts as a primitive lung bud in early embryonic life and undergoes several morphological stages which continue into postnatal life. Each stage of lung growth is a result of complex and tightly regulated events governed by physical, environmental, hormonal and genetic factors. Fetal lung liquid and fetal breathing movements are by far the most important determinants of lung growth. Although timing of the stages of lung growth in animals do not mimic that of human, numerous animal studies, mainly on sheep and rat, have given us a better understanding of the regulators of lung growth. Insight into the genetic basis of lung growth has helped us understand and improve management of complex life threatening congenital abnormalities such as congenital diaphragmatic hernia and pulmonary hypoplasia. Although advances in perinatal medicine have improved survival of preterm infants, premature birth is perhaps still the most important factor for adverse lung growth.

  12. Heterogeneous neutron-leakage model for PWR pin-by-pin calculation

    International Nuclear Information System (INIS)

    Li, Yunzhao; Zhang, Bin; Wu, Hongchun; Shen, Wei

    2017-01-01

    Highlights: •The derivation of the formula of the leakage model is introduced. This paper evaluates homogeneous and heterogeneous leakage models used in PWR pin-by-pin calculation. •The implements of homogeneous and heterogeneous leakage models used in pin-cell homogenization of the lattice calculation are studied. A consistent method of cooperation between the heterogeneous leakage model and the pin-cell homogenization theory is proposed. •Considering the computational cost, a new buckling search scheme is proposed to reach the convergence faster. The computational cost of the newly proposed neutron balance scheme is much less than the power-method scheme and the linear-interpolation scheme. -- Abstract: When assembly calculation is performed with the reflective boundary condition, a leakage model is usually required in the lattice code. The previous studies show that the homogeneous leakage model works effectively for the assembly homogenization. However, it becomes different and unsettled for the pin-cell homogenization. Thus, this paper evaluates homogeneous and heterogeneous leakage models used in pin-by-pin calculation. The implements of homogeneous and heterogeneous leakage models used in pin-cell homogenization of the lattice calculation are studied. A consistent method of cooperation between the heterogeneous leakage model and the pin-cell homogenization theory is proposed. Considering the computational cost, a new buckling search scheme is proposed to reach the convergence faster. For practical reactor-core applications, the diffusion coefficients determined by the transport cross-section or by the leakage model are compared with each other to determine which one is more accurate for the Pressurized Water Reactor pin-by-pin calculation. Numerical results have demonstrated that the heterogeneous leakage model together with the diffusion coefficient determined by the heterogeneous leakage model would have the higher accuracy. The new buckling search

  13. Cement Leakage in Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures: Analysis of Risk Factors.

    Science.gov (United States)

    Xie, Weixing; Jin, Daxiang; Ma, Hui; Ding, Jinyong; Xu, Jixi; Zhang, Shuncong; Liang, De

    2016-05-01

    The risk factors for cement leakage were retrospectively reviewed in 192 patients who underwent percutaneous vertebral augmentation (PVA). To discuss the factors related to the cement leakage in PVA procedure for the treatment of osteoporotic vertebral compression fractures. PVA is widely applied for the treatment of osteoporotic vertebral fractures. Cement leakage is a major complication of this procedure. The risk factors for cement leakage were controversial. A retrospective review of 192 patients who underwent PVA was conducted. The following data were recorded: age, sex, bone density, number of fractured vertebrae before surgery, number of treated vertebrae, severity of the treated vertebrae, operative approach, volume of injected bone cement, preoperative vertebral compression ratio, preoperative local kyphosis angle, intraosseous clefts, preoperative vertebral cortical bone defect, and ratio and type of cement leakage. To study the correlation between each factor and cement leakage ratio, bivariate regression analysis was employed to perform univariate analysis, whereas multivariate linear regression analysis was employed to perform multivariate analysis. The study included 192 patients (282 treated vertebrae), and cement leakage occurred in 100 vertebrae (35.46%). The vertebrae with preoperative cortical bone defects generally exhibited higher cement leakage ratio, and the leakage is typically type C. Vertebrae with intact cortical bones before the procedure tend to experience type S leakage. Univariate analysis showed that patient age, bone density, number of fractured vertebrae before surgery, and vertebral cortical bone were associated with cement leakage ratio (Pcement leakage are bone density and vertebral cortical bone defect, with standardized partial regression coefficients of -0.085 and 0.144, respectively. High bone density and vertebral cortical bone defect are independent risk factors associated with bone cement leakage.

  14. Epidemiology of Lung Cancer

    Science.gov (United States)

    Brock, Malcolm V.; Ford, Jean G.; Samet, Jonathan M.; Spivack, Simon D.

    2013-01-01

    Background: Ever since a lung cancer epidemic emerged in the mid-1900s, the epidemiology of lung cancer has been intensively investigated to characterize its causes and patterns of occurrence. This report summarizes the key findings of this research. Methods: A detailed literature search provided the basis for a narrative review, identifying and summarizing key reports on population patterns and factors that affect lung cancer risk. Results: Established environmental risk factors for lung cancer include smoking cigarettes and other tobacco products and exposure to secondhand tobacco smoke, occupational lung carcinogens, radiation, and indoor and outdoor air pollution. Cigarette smoking is the predominant cause of lung cancer and the leading worldwide cause of cancer death. Smoking prevalence in developing nations has increased, starting new lung cancer epidemics in these nations. A positive family history and acquired lung disease are examples of host factors that are clinically useful risk indicators. Risk prediction models based on lung cancer risk factors have been developed, but further refinement is needed to provide clinically useful risk stratification. Promising biomarkers of lung cancer risk and early detection have been identified, but none are ready for broad clinical application. Conclusions: Almost all lung cancer deaths are caused by cigarette smoking, underscoring the need for ongoing efforts at tobacco control throughout the world. Further research is needed into the reasons underlying lung cancer disparities, the causes of lung cancer in never smokers, the potential role of HIV in lung carcinogenesis, and the development of biomarkers. PMID:23649439

  15. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran [Univ. of Gaevle, Gaevle (Sweden); Meijer, Jan-Erik; Rosqvist, Haakan [NSR AB, Helsingborg (Sweden)

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  16. Secure Mobile Agent from Leakage-Resilient Proxy Signatures

    Directory of Open Access Journals (Sweden)

    Fei Tang

    2015-01-01

    Full Text Available A mobile agent can sign a message in a remote server on behalf of a customer without exposing its secret key; it can be used not only to search for special products or services, but also to make a contract with a remote server. Hence a mobile agent system can be used for electronic commerce as an important key technology. In order to realize such a system, Lee et al. showed that a secure mobile agent can be constructed using proxy signatures. Intuitively, a proxy signature permits an entity (delegator to delegate its signing right to another entity (proxy to sign some specified messages on behalf of the delegator. However, the proxy signatures are often used in scenarios where the signing is done in an insecure environment, for example, the remote server of a mobile agent system. In such setting, an adversary could launch side-channel attacks to exploit some leakage information about the proxy key or even other secret states. The proxy signatures which are secure in the traditional security models obviously cannot provide such security. Based on this consideration, in this paper, we design a leakage-resilient proxy signature scheme for the secure mobile agent systems.

  17. AN ADVANCED LEAKAGE SCHEME FOR NEUTRINO TREATMENT IN ASTROPHYSICAL SIMULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Perego, A. [Institut für Kernphysik, Technische Universität Darmstadt, Schlossgartenstraße 2, D-64289 Darmstadt (Germany); Cabezón, R. M. [Physics Department, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Käppeli, R., E-mail: albino.perego@physik.tu-darmstadt.de [Seminar for Applied Mathematics, ETH Zürich, Rämistrasse 101, 8092 Zürich (Switzerland)

    2016-04-15

    We present an Advanced Spectral Leakage (ASL) scheme to model neutrinos in the context of core-collapse supernovae (CCSNe) and compact binary mergers. Based on previous gray leakage schemes, the ASL scheme computes the neutrino cooling rates by interpolating local production and diffusion rates (relevant in optically thin and thick regimes, respectively) separately for discretized values of the neutrino energy. Neutrino trapped components are also modeled, based on equilibrium and timescale arguments. The better accuracy achieved by the spectral treatment allows a more reliable computation of neutrino heating rates in optically thin conditions. The scheme has been calibrated and tested against Boltzmann transport in the context of Newtonian spherically symmetric models of CCSNe. ASL shows a very good qualitative and a partial quantitative agreement for key quantities from collapse to a few hundreds of milliseconds after core bounce. We have proved the adaptability and flexibility of our ASL scheme, coupling it to an axisymmetric Eulerian and to a three-dimensional smoothed particle hydrodynamics code to simulate core collapse. Therefore, the neutrino treatment presented here is ideal for large parameter-space explorations, parametric studies, high-resolution tests, code developments, and long-term modeling of asymmetric configurations, where more detailed neutrino treatments are not available or are currently computationally too expensive.

  18. Endoscopic Management of Bile Leakage after Liver Transplantation

    Science.gov (United States)

    Oh, Dongwook; Lee, Sung Koo; Song, Tae Jun; Park, Do Hyun; Lee, Sang Soo; Seo, Dong-Wan; Kim, Myung-Hwan

    2015-01-01

    Background/Aims Endoscopic retrograde cholangiopancreatography (ERCP) can be an effective treatment for bile leakage after liver transplantation. We evaluated the efficacy of endoscopic treatment in liver transplantation in patients who developed bile leaks. Methods Forty-two patients who developed bile leaks after liver transplantation were included in the study. If a bile leak was observed on ERCP, a sphincterotomy was performed, and a nasobiliary catheter was then inserted. If a bile leak was accompanied by a bile duct stricture, either the stricture was dilated with balloons, followed by nasobiliary catheter insertion across the bile duct stricture, or endoscopic retrograde biliary drainage was performed. Results In the bile leakage alone group (22 patients), endoscopic treatment was technically successful in 19 (86.4%) and clinically successful in 17 (77.3%) cases. Among the 20 patients with bile leaks with bile duct strictures, endoscopic treatment was technically successful in 13 (65.0%) and clinically successful in 10 (50.0%) cases. Among the 42 patients who underwent ERCP, technical success was achieved in 32 (76.2%) cases and clinical success was achieved in 27 (64.3%) cases. Conclusions ERCP is an effective and safe therapeutic modality for bile leaks after liver transplantation. ERCP should be considered as an initial therapeutic modality in post-liver transplantation patients. PMID:25717048

  19. Leakage current measurements on pixelated CdZnTe detectors

    International Nuclear Information System (INIS)

    Dirks, B.P.F.; Blondel, C.; Daly, F.; Gevin, O.; Limousin, O.; Lugiez, F.

    2006-01-01

    In the field of the R and D of a new generation hard X-ray cameras for space applications we focus on the use of pixelated CdTe or CdZnTe semiconductor detectors. They are covered with 64 (0.9x0.9 mm 2 ) or 256 (0.5x0.5 mm 2 ) pixels, surrounded by a guard ring and operate in the energy ranging from several keV to 1 MeV, at temperatures between -20 and +20 o C. A critical parameter in the characterisation of these detectors is the leakage current per pixel under polarisation (∼50-500 V/mm). In operation mode each pixel will be read-out by an integrated spectroscopy channel of the multi-channel IDeF-X ASIC currently developed in our lab. The design and functionality of the ASIC depends directly on the direction and value of the current. A dedicated and highly insulating electronics circuit is designed to automatically measure the current in each individual pixel, which is in the order of tens of pico-amperes. Leakage current maps of different CdZnTe detectors of 2 and 6 mm thick and at various temperatures are presented and discussed. Defect density diagnostics have been performed by calculation of the activation energy of the material

  20. Low standby leakage 12T SRAM cell characterisation

    Science.gov (United States)

    Yadav, Arjun; Nakhate, Sangeeta

    2016-09-01

    In this work, a low power and variability-aware static random access memory (SRAM) architecture based on a twelve-transistor (12T) cell is proposed. This cell obtains low static power dissipation due to a parallel global latch (G-latch) and storage latch (S-latch), along with a global wordline (GWL), which offer a high cell ratio and pull-up ratio for reliable read and write operations and a low cell ratio and pull-up ratio during idle mode to reduce the standby power dissipation. In the idle state, only the S-latch stores bits, while the G-latch is isolated from the S-latch and the GWL is deactivated. The leakage power consumption of the proposed SRAM cell is thereby reduced by 38.7% compared to that of the conventional six-transistor (6T) SRAM cell. This paper evaluates the impact of the chip supply voltage and surrounding temperature variations on the standby leakage power and observes considerable improvement in the power dissipation. The read/write access delay, read static noise margin (SNM) and write SNM were evaluated, and the results were compared with those of the standard 6T SRAM cell. The proposed cell, when compared with the existing cell using the Monte Carlo method, shows an appreciable improvement in the standby power dissipation and layout area.