WorldWideScience

Sample records for lung spect evidence

  1. Quantitative study on lung volume and lung perfusion using SPECT and CT in thoracal tumors

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Strauss, L.G.

    1988-01-01

    22 patients with space occupying lesions in the thoracal region were investigated by computer tomography and by perfusion scintigraphy using SPECT. In order to evaluate the CT images quantitatively, the lung volume was determined using approximation method and compared with the perfusion in the SPECT study. For this, anatomically equivalent transaxial SPECT slices had been coordinated to the CT slices. Between the determined lung volumes and the activity in the ocrresponding layers, a statistically significant correlation was found. It could be shown that the stronger perfusion, frequently observed at the right side of the healthy lung, may be explained by an higher volume of the right pulmonary lobe. Whereas in benign displacing processes the relation activity to volume was similar to the one of the healthy lung, a strongly reduced perfusion together with inconspicuous lung volumes became apparent with malignant tumors. In addition to the great morphological evidence of CT and SPECT studies, additional informations regarding the dignity of displacing processes may be derived from the quantitative evaluation of both methods. (orig.) [de

  2. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  3. Measurement of lung water with SPECT

    International Nuclear Information System (INIS)

    Chu, R.Y.L.; Ficken, V.J.; Ekeh, S.U.; Ryals, C.J.; Allen, E.W.; Basmadjian, G.

    1990-01-01

    This paper investigates the use of iodoantipyrine (IAP) labeled with radioactive iodine (I-123) and single photon emission tomography (SPECT) to measure lung water. I-123 IAP was injected intravenously to six New Zealand White rabbits under anesthesia. After 1 hour, Tc-99m macroaggregates of albumin (MAA) were injected. SPECT imaging was performed in dual-energy mode. After a blood sample was drawn, the animals were sacrificed, and the lungs were removed. Blood samples were assayed for radioactivity. The lungs were weighed, dried, and weighted again to determine water content. The product of area defined by MAA in a tomogram and IAP count rate of central pixels of that region in the corresponding tomogram was taken as the relative amount of IAP in each lung

  4. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  5. Quantative pre-surgical lung function estimation with SPECT/CT

    International Nuclear Information System (INIS)

    Bailey, Dale L.; Timmins, Sophi; Harris, Benjamin E.; Bailey, Elizabeth A.; Roach, Paul J.; Willowson, Kathy P.

    2009-01-01

    Full text: Objectives: To develop methodology to predict lobar lung function based on SPECT/CT ventilation 6 k perfusion (V/Q) scanning in candidates for lobectomy for lung cancer. This combines two development areas from our group: quantitative SPECT based on CT-derived corrections for scattering and attenuation of photons, and SPECT V/Q scanning with lobar segmentation from CT Six patients underwent baseline pulmonary function testing (PFT) including spirometry, measurement of DLCO and cardio-pulmonary exercise testing. A SPECT/CT V/Q scan was acquired at baseline. Using in-house software each lobe was anatomically defined using CT to provide lobar ROIs which could be applied to the SPECT data. From these, individual lobar contribution to overall function was calculated from counts within the lobe and post-operative FEVl, DLCO and V02 peak were predicted. This was compared with the quantitative planar scan method using 3 rectangular ROIs over each lung.

  6. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  7. Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT.

    Science.gov (United States)

    Cheimariotis, Grigorios-Aris; Al-Mashat, Mariam; Haris, Kostas; Aletras, Anthony H; Jögi, Jonas; Bajc, Marika; Maglaveras, Nicolaos; Heiberg, Einar

    2018-02-01

    Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with reference computed tomography (CT) volumes. A total of 77 subjects (69 patients with obstructive lung disease, and 8 subjects without apparent perfusion of ventilation loss) performed low-dose CT followed by ventilation/perfusion (V/P) SPECT examination in a hybrid gamma camera system. In the training phase, lung shapes from the 57 anatomical low-dose CT images were used to construct two active shape models (right lung and left lung) which were then used for image segmentation. The algorithm was validated in 20 patients, comparing its results to reference delineation of corresponding CT images, and by comparing automatic segmentation to manual delineations in SPECT images. The Dice coefficient between automatic SPECT delineations and manual SPECT delineations were 0.83 ± 0.04% for the right and 0.82 ± 0.05% for the left lung. There was statistically significant difference between reference volumes from CT and automatic delineations for the right (R = 0.53, p = 0.02) and left lung (R = 0.69, p automatic quantification of wide range of measurements.

  8. Lung Dose Calculation With SPECT/CT for 90Yittrium Radioembolization of Liver Cancer

    International Nuclear Information System (INIS)

    Yu, Naichang; Srinivas, Shaym M.; DiFilippo, Frank P.; Shrikanthan, Sankaran; Levitin, Abraham; McLennan, Gordon; Spain, James; Xia, Ping; Wilkinson, Allan

    2013-01-01

    Purpose: To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ( 99m Tc-MAA) single photon emission CT (SPECT)/CT for 90 Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Methods and Materials: Images of 71 patients who had SPECT/CT and PS images of 99m Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. Results: The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. Conclusions: A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on 99m Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended

  9. Lung perfusion SPECT in predicting postoperative pulmonary function in lung cancer

    International Nuclear Information System (INIS)

    Hirose, Yoshiaki; Imaeda, Takeyoshi; Doi, Hidetaka; Kokubo, Mitsuharu; Sakai, Satoshi; Hirose, Hajime

    1993-01-01

    The aim of this prospective study is to evaluate the availability of preoperative perfusion SPECT in predicting postoperative pulmonary function following resection. Twenty-three patients with lung cancer who were candidates for lobectomy were investigated preoperatively with spirometry, x-ray computed tomography and 99m Tc-macroaggregated albumin SPECT. Their postoperative pulmonary functions were predicted with these examinations. The forced vital capacity and the forced expiratory volume in one second were selected as parameters for overall pulmonary function. The postoperative pulmonary function was predicted by the following formula: Predicted postoperative value=observed preoperative value x precent perfusion of the lung not to be resected. The patients were reinvestigated with spirometry at 3 months and 6 months after lobectomy, and the values obtained were statistically compared with the predicted values. Close relationships were found between predicted and observed forced vital capacity (r=0.87, p<0.001), and predicted and observed forced expiratory volume in one second (r=0.90, p<0.001). The accurate prediction of pulmonary function after lobectomy could be achieved by means of lung perfusion SPECT. (author)

  10. Quantitative pre-surgical lung function estimation with SPECT/CT

    International Nuclear Information System (INIS)

    Bailey, D. L.; Willowson, K. P.; Timmins, S.; Harris, B. E.; Bailey, E. A.; Roach, P. J.

    2009-01-01

    Full text:Objectives: To develop methodology to predict lobar lung function based on SPECT/CT ventilation and perfusion (V/Q) scanning in candidates for lobectomy for lung cancer. Methods: This combines two development areas from our group: quantitative SPECT based on CT-derived corrections for scattering and attenuation of photons, and SPECT V/Q scanning with lobar segmentation from CT. Eight patients underwent baseline pulmonary function testing (PFT) including spirometry, measure of DLCO and cario-pulmonary exercise testing. A SPECT/CT V/Q scan was acquired at baseline. Using in-house software each lobe was anatomically defined using CT to provide lobar ROIs which could be applied to the SPECT data. From these, individual lobar contribution to overall function was calculated from counts within the lobe and post-operative FEV1, DLCO and VO2 peak were predicted. This was compared with the quantitative planar scan method using 3 rectangular ROIs over each lung. Results: Post-operative FEV1 most closely matched that predicted by the planar quantification method, with SPECT V/Q over-estimating the loss of function by 8% (range - 7 - +23%). However, post-operative DLCO and VO2 peak were both accurately predicted by SPECT V/Q (average error of 0 and 2% respectively) compared with planar. Conclusions: More accurate anatomical definition of lobar anatomy provides better estimates of post-operative loss of function for DLCO and VO2 peak than traditional planar methods. SPECT/CT provides the tools for accurate anatomical defintions of the surgical target as well as being useful in producing quantitative 3D functional images for ventilation and perfusion.

  11. Measurement of lung volume by lung perfusion scanning using SPECT and prediction of postoperative respiratory function

    International Nuclear Information System (INIS)

    Andou, Akio; Shimizu, Nobuyosi; Maruyama, Shuichiro

    1992-01-01

    Measurement of lung volume by lung perfusion scanning using single photon emission computed tomography (SPECT) and its usefulness for the prediction of respiratory function after lung resection were investigated. The lung volumes calculated in 5 patients by SPECT (threshold level 20%) using 99m Tc-macroaggregated albumin (MAA), related very closely to the actually measured lung volumes. This results prompted us to calculate the total lung volume and the volume of the lobe to be resected in 18 patients with lung cancer by SPECT. Based on the data obtained, postoperative respiratory function was predicted. The predicted values of forced vital capacity (FVC), forced expiratory volume (FEV 1.0 ), and maximum vital volume (MVV) showed closer correlations with the actually measured postoperative values (FVC, FEV 1.0 , MVV : r=0.944, r=0.917, r=0.795 respectively), than the values predicted by the ordinary lung perfusion scanning. This method facilitates more detailed evaluation of local lung function on a lobe-by-lobe basis, and can be applied clinically to predict postoperative respiratory function. (author)

  12. Lung Dose Calculation With SPECT/CT for {sup 90}Yittrium Radioembolization of Liver Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Naichang, E-mail: yun@ccf.org [Department of Radiation Oncology, Cleveland Clinic, Cleveland, OH (United States); Srinivas, Shaym M.; DiFilippo, Frank P.; Shrikanthan, Sankaran [Department of Nuclear Medicine, Cleveland Clinic, Cleveland, OH (United States); Levitin, Abraham; McLennan, Gordon; Spain, James [Department of Interventional Radiology, Cleveland Clinic, Cleveland, OH (United States); Xia, Ping; Wilkinson, Allan [Department of Radiation Oncology, Cleveland Clinic, Cleveland, OH (United States)

    2013-03-01

    Purpose: To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ({sup 99m}Tc-MAA) single photon emission CT (SPECT)/CT for {sup 90}Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Methods and Materials: Images of 71 patients who had SPECT/CT and PS images of {sup 99m}Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. Results: The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. Conclusions: A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on {sup 99m}Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended.

  13. Lung dose calculation with SPECT/CT for ⁹⁰Yittrium radioembolization of liver cancer.

    Science.gov (United States)

    Yu, Naichang; Srinivas, Shaym M; Difilippo, Frank P; Shrikanthan, Sankaran; Levitin, Abraham; McLennan, Gordon; Spain, James; Xia, Ping; Wilkinson, Allan

    2013-03-01

    To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ((99m)Tc-MAA) single photon emission CT (SPECT)/CT for (90)Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Images of 71 patients who had SPECT/CT and PS images of (99m)Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on (99m)Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. The incorporation of SPECT functional lung imaging into inverse radiotherapy planning for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Christian, Judith A.; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; McNair, Helen A.; Cronin, Bernadette; Courbon, Frederic; Bedford, James L.; Brada, Michael

    2005-01-01

    Background and purpose: Patients with non-small cell lung cancer (NSCLC) often have inhomogeneous lung perfusion. Radiotherapy planning computed tomography (CT) scans have been accurately co-registered with lung perfusion single photon emission computed tomography (SPECT) scans to design radiotherapy treatments which limit dose to healthy 'perfused' lung. Patients and methods: Patients with localised NSCLC had CT and SPECT scans accurately co-registered in the planning system. The SPECT images were used to define a volume of perfused 'functioning' lung (FL). Inverse planning software was used to create 3D-conformal plans, the planning objective being either to minimise the dose to whole lungs (WL) or to minimise the dose to FL. Results: Four plans were created for each of six patients. The mean difference in volume between WL and FL was 1011.7 cm 3 (range 596.2-1581.1 cm 3 ). One patient with bilateral upper lobe perfusion deficits had a 16% reduction in FLV 2 (the percentage volume of functioning lung receiving ≥20 Gy). The remaining patients had inhomogeneous perfusion deficits such that inverse planning was not able to sufficiently optimise beam angles to avoid functioning lung. Conclusion: SPECT perfusion images can be accurately co-registered with radiotherapy planning CT scans and may be helpful in creating treatment plans for patients with large perfusion deficits

  15. Clinical value of 99Tcm-octreotide SPECT/CT in diagnostics of lung cancer

    International Nuclear Information System (INIS)

    Liu Xiaofang; Li Mei; Liu Yong; Li Ran; Xu Jie; Sun yongchang; Dai Haojie

    2012-01-01

    Objective: To evaluate the clinical value of 99 Tc m -Octreotide SPECT-CT in the diagnosis of lung cancer. Methods: Sixty-five consecutive patients with suspected lung cancer received intravenous injection of 740 MBq 99 Tc m -Octreotide and additional SPECT images of the chest were performed at 4h post injection. The SPECT/CT images were interpreted separately. The tumor uptake of 99 Tc m -Octreotide was visually determined and then measured and expressed as the activity ratio of tumor to normal tissues (T/N). The differences between lung cancer and benign lung lesion and between SCLC and NSCLC, and between adenocarcinoma and squamous carcinoma were studied by statistical analysis. Moreover, the receiver operating characteristic ROC curves were plotted and the predicted probabilities and areas under the curve were calculated. Results: Fifty-one patients and fourteen patients in 65 cases were diagnosed as lung cancer and benign lung lesion by histopathological analysis, respectively. The sensitivity, specificity, positive predictive value and negative predictive value of 99 Tc m -Octreotide SPECT/CT in diagnosis of lung cancer were 92.2%, 85.7%, 95.9% and 75%, respectively. The area under ROC curve was 0.889 (P 99 Tc m -Octreotide SPECT/CT could play an important role in the diagnosis of lung cancer, and it may be useful for identifying SCLC and NSCLC. (authors)

  16. Reproducibility of Lobar Perfusion and Ventilation Quantification Using SPECT/CT Segmentation Software in Lung Cancer Patients.

    Science.gov (United States)

    Provost, Karine; Leblond, Antoine; Gauthier-Lemire, Annie; Filion, Édith; Bahig, Houda; Lord, Martin

    2017-09-01

    Planar perfusion scintigraphy with 99m Tc-labeled macroaggregated albumin is often used for pretherapy quantification of regional lung perfusion in lung cancer patients, particularly those with poor respiratory function. However, subdividing lung parenchyma into rectangular regions of interest, as done on planar images, is a poor reflection of true lobar anatomy. New tridimensional methods using SPECT and SPECT/CT have been introduced, including semiautomatic lung segmentation software. The present study evaluated inter- and intraobserver agreement on quantification using SPECT/CT software and compared the results for regional lung contribution obtained with SPECT/CT and planar scintigraphy. Methods: Thirty lung cancer patients underwent ventilation-perfusion scintigraphy with 99m Tc-macroaggregated albumin and 99m Tc-Technegas. The regional lung contribution to perfusion and ventilation was measured on both planar scintigraphy and SPECT/CT using semiautomatic lung segmentation software by 2 observers. Interobserver and intraobserver agreement for the SPECT/CT software was assessed using the intraclass correlation coefficient, Bland-Altman plots, and absolute differences in measurements. Measurements from planar and tridimensional methods were compared using the paired-sample t test and mean absolute differences. Results: Intraclass correlation coefficients were in the excellent range (above 0.9) for both interobserver and intraobserver agreement using the SPECT/CT software. Bland-Altman analyses showed very narrow limits of agreement. Absolute differences were below 2.0% in 96% of both interobserver and intraobserver measurements. There was a statistically significant difference between planar and SPECT/CT methods ( P software is highly reproducible. This tridimensional method yields statistically significant differences in measurements for right lung lobes when compared with planar scintigraphy. We recommend that SPECT/CT-based quantification be used for all lung

  17. Pixel based statistical analysis of differences between lung SPECT images: methodological aspects

    International Nuclear Information System (INIS)

    Bendada, S.; Rocchisani, J.L.M.; Moretti, J.L.

    2002-01-01

    The statistical parametric mapping method is applied in Neurology for activation studies. We had adapted this powerful method on Lungs SPECT to help for the diagnosis and the follow-up of pulmonary embolism and other lung diseases. The SPECT slices of pairs of examination were normalized thanks to the total acquired counts, reconstruction background subtracted, smoothed and realigned. A parametric image of statistical differences was finally computed. We had thus obtained a 3D image showing regions of improved or altered region under treatment. A tuning of the various parameters could lead to more accurate image. This new approach of lung SPECT processing appears to be a promising useful tool for the physician. (author)

  18. SPECT/CT of lung nodules using 111In-DOTA-c(RGDfK) in a mouse lung carcinogenesis model.

    Science.gov (United States)

    Hayakawa, Takuya; Mutoh, Michihiro; Imai, Toshio; Tsuta, Koji; Yanaka, Akinori; Fujii, Hirofumi; Yoshimoto, Mitsuyoshi

    2013-08-01

    Lung cancer is one of the leading causes of cancer-related deaths worldwide, including Japan. Although computed tomography (CT) can detect small lung lesions such as those appearing as ground glass opacity, it cannot differentiate between malignant and non-malignant lesions. Previously, we have shown that single photon emission computed tomography (SPECT) imaging using (111)In-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid-cyclo-(Arg-Gly-Asp-D-Phe-Lys) (DOTA-c(RGDfK)), an imaging probe of αvβ3 integrin, is useful for the early detection of pancreatic cancer in a hamster pancreatic carcinogenesis model. In this study, we aimed to assess the usefulness of SPECT/CT with (111)In-DOTA-c(RGDfK) for the evaluation of the malignancy of lung cancer. Lung tumors were induced by a single intraperitoneal injection (250 mg/kg) of urethane in male A/J mice. Twenty-six weeks after the urethane treatment, SPECT was performed an hour after injection of (111)In-DOTA-c(RGDfK). Following this, the radioactivity ratios of tumor to normal lung tissue were measured by autoradiography (ARG) in the excised lung samples. We also examined the expression of αvβ3 integrin in mouse and human lung samples. Urethane treatment induced 5 hyperplasias, 41 adenomas and 12 adenocarcinomas in the lungs of 8 A/J mice. SPECT with (111)In-DOTA-c(RGDfK) could clearly visualize lung nodules, though we failed to detect small lung nodules like adenoma and hyperplasias (adenocarcinoma: 66.7%, adenoma: 33.6%, hyperplasia: 0.0%). ARG analysis revealed significant uptake of (111)In-DOTA-c(RGDfK) in all the lesions. Moreover, tumor to normal lung tissue ratios increased along with the progression of carcinogenesis. Histopathological examination using human lung tissue samples revealed clear up-regulation of αvβ3 integrin in well-differentiated adenocarcinoma (Noguchi type B and C) rather than atypical adenomatous hyperplasia. Although there are some limitations in evaluating the malignancy of

  19. Respiratory lung motion analysis using a nonlinear motion correction technique for respiratory-gated lung perfusion SPECT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Haneishi, Hideaki; Iwanaga, Hideyuki; Suga, Kazuyoshi

    2007-01-01

    This study evaluated the respiratory motion of lungs using a nonlinear motion correction technique for respiratory-gated single photon emission computed tomography (SPECT) images. The motion correction technique corrects the respiratory motion of the lungs nonlinearly between two-phase images obtained by respiratory-gated SPECT. The displacement vectors resulting from respiration can be computed at every location of the lungs. Respiratory lung motion analysis is carried out by calculating the mean value of the body axis component of the displacement vector in each of the 12 small regions into which the lungs were divided. In order to enable inter-patient comparison, the 12 mean values were normalized by the length of the lung region along the direction of the body axis. This method was applied to 25 Technetium (Tc)-99m-macroaggregated albumin (MAA) perfusion SPECT images, and motion analysis results were compared with the diagnostic results. It was confirmed that the respiratory lung motion reflects the ventilation function. A statistically significant difference in the amount of the respiratory lung motion was observed between the obstructive pulmonary diseases and other conditions, based on an unpaired Student's t test (P<0.0001). A difference in the motion between normal lungs and lungs with a ventilation obstruction was detected by the proposed method. This method is effective for evaluating obstructive pulmonary diseases such as pulmonary emphysema and diffuse panbronchiolitis. (author)

  20. Lung ventilation-perfusion imbalance in pulmonary emphysema. Assessment with automated V/Q quotient SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Koike, Hiroaki; Iwanaga, Hideyuki; Tokuda, Osamu; Okada, Munemasa; Matsunaga, Naofumi

    2010-01-01

    Tc-99m-Technegas-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P<0.0001 and P<0.001, respectively), and a significant correlation was found between SD and A-aDO2 (P<0.0001). V/Q quotient SPECT appears to be more sensitive to detect emphysematous lungs compared with morphologic CT in patients with emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema. (author)

  1. Lung ventilation-perfusion imbalance in pulmonary emphysema: assessment with automated V/Q quotient SPECT.

    Science.gov (United States)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Koike, Hiroaki; Iwanaga, Hideyuki; Tokuda, Osamu; Okada, Munemasa; Matsunaga, Naofumi

    2010-05-01

    Tc-99m-Technegas-MAA single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema.

  2. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  3. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    International Nuclear Information System (INIS)

    Suga, K.; Yasuhiko, K.; Iwanaga, H.; Tokuda, O.; Matsunaga, N.

    2009-01-01

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  4. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Suga, K.; Yasuhiko, K. (Dept. of Radiology, St. Hill Hospital, Ube, Yamaguchi (Japan)); Iwanaga, H.; Tokuda, O.; Matsunaga, N. (Dept. of Radiology, Yamaguchi Univ. School of Medicine, Ube, Yamaguchi (Japan))

    2009-01-15

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  5. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT.

    Science.gov (United States)

    Suga, K; Yasuhiko, K; Iwanaga, H; Tokuda, O; Matsunaga, N

    2009-01-01

    The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Although further validation is required, our results indicate that heterogeneous pulmonary arterial

  6. Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates

    International Nuclear Information System (INIS)

    Takenaka, Daisuke; Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Onishi, Yumiko; Matsumoto, Keiko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2010-01-01

    Purpose: To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Materials and methods: Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV 1 ) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Results: Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60 ≤ r ≤ -0.42, p < 0.05). Conclusion: Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.

  7. Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates

    Energy Technology Data Exchange (ETDEWEB)

    Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.j [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2, Minatojima Minamimachi Chuo-ku, Kobe, Hyogo, 650-0047 (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Matsumoto, Keiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Department of Radiology, University of Yamanashi, 1110 Shimogato, Chuo, Yamanashi, 409-3898 (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan)

    2010-06-15

    Purpose: To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Materials and methods: Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV{sub 1}) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Results: Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60 {<=} r {<=} -0.42, p < 0.05). Conclusion: Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.

  8. SU-F-T-687: Comparison of SPECT/CT-Based Methodologies for Estimating Lung Dose from Y-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Kost, S; Yu, N [Cleveland Clinic, Cleveland, OH (United States); Lin, S [Cleveland State University, Cleveland, OH (United States)

    2016-06-15

    Purpose: To compare mean lung dose (MLD) estimates from 99mTc macroaggregated albumin (MAA) SPECT/CT using two published methodologies for patients treated with {sup 90}Y radioembolization for liver cancer. Methods: MLD was estimated retrospectively using two methodologies for 40 patients from SPECT/CT images of 99mTc-MAA administered prior to radioembolization. In these two methods, lung shunt fractions (LSFs) were calculated as the ratio of scanned lung activity to the activity in the entire scan volume or to the sum of activity in the lung and liver respectively. Misregistration of liver activity into the lungs during SPECT acquisition was overcome by excluding lung counts within either 2 or 1.5 cm of the diaphragm apex respectively. Patient lung density was assumed to be 0.3 g/cm{sup 3} or derived from CT densitovolumetry respectively. Results from both approaches were compared to MLD determined by planar scintigraphy (PS). The effect of patient size on the difference between MLD from PS and SPECT/CT was also investigated. Results: Lung density from CT densitovolumetry is not different from the reference density (p = 0.68). The second method resulted in lung dose of an average 1.5 times larger lung dose compared to the first method; however the difference between the means of the two estimates was not significant (p = 0.07). Lung dose from both methods were statistically different from those estimated from 2D PS (p < 0.001). There was no correlation between patient size and the difference between MLD from PS and both SPECT/CT methods (r < 0.22, p > 0.17). Conclusion: There is no statistically significant difference between MLD estimated from the two techniques. Both methods are statistically different from conventional PS, with PS overestimating dose by a factor of three or larger. The difference between lung doses estimated from 2D planar or 3D SPECT/CT is not dependent on patient size.

  9. Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Kang, Yeon Koo; Ha, Seung Gyun [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); and others

    2017-06-15

    Until now, there was no single standardized regional segmentation method of planar lung perfusion scan. We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients. Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted. The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of % uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation. The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.

  10. Quantification of 99mTc-MIBI lung uptake in myocardial SPECT studies

    International Nuclear Information System (INIS)

    Qu Wanying; Lu Zhenping; Zhou Ying; He Qin

    1996-01-01

    To assess the significance of 99m Tc-MIBI lung uptake during myocardial SPECT studies in the evaluation of left ventricular dysfunction. 42 control subjects and 65 patients with coronary artery disease (CAD) were investigated with 99m Tc-MIBI myocardial SPECT and radionuclide ventriculography (RNV) within 1 week. The lung-to-heart ratios (LHR) both at rest and exercise were calculated from the anterior projection of the SPECT image sets. The left ventricular ejection fraction (LVEF) was determined using RNV. In the control group, a significant decrease in LHR was observed during exercise (P<0.01). The CAD group showed significantly high LHR values both at rest and exercise. A negative correlation was observed between LHR values and LVEF at rest (r -0.6234, P<0.001) and exercise (r = -0.6113, P<0.001). LHR both at rest and exercise are significantly correlated with LVEF and may be useful in the evaluation of left ventricular function

  11. [(99)Tc(m)N-NOET dual-phase SPECT in differential diagnosis of benign and malignant lung tumors].

    Science.gov (United States)

    Liu, Haiyan; Li, Sijin; Yang, Suyun; Wu, Zhifang

    2014-01-01

    To investigate the value of (99)Tc(m)N-NOET dual-phase SPECT in differential diagnosis of benign and malignant lung tumors. CT scan, early (20 to 30 min) and delayed (2 h) imaging of NOET SPECT were performed on 61 patients suspected of lung lesions before operation. The results were compared with the pathological findings. All cases were not treated with radiotherapy, chemotherapy or surgery before checks. Moreover, all patients had pathological diagnosis. To determine the value in differential diagnosis of tumors by analyzing the tumor uptake and excretion of (99)Tc(m)N-NOET, and the results were compared with that of CT. The value of early T/N ratio (ER) in the malignant (G1) and benign (G2) groups was 1.25 ± 0.15 and 1.09 ± 0.11 (P 0.05). The ER, DR and RI of NOET SPECT in the malignant patients were not significantly correlated with TNM staging, pathological types, tumor diameter, cavity in the lung tumor mass, history of smoking, tumor size and patient gender (P > 0.05). The sensitivity of NOET dual-phase SPECT and CT in the differential diagnosis of benign and malignant lung tumors was 94.1% vs. 90.2%, specificity was 70.0% vs. 80.0% , positive predictive value (PPV) was 94.1% vs. 95.8%, negative predictive value (NPV) was 70.0% vs. 61.5 %, and accuracy was 90.2%. vs. 88.5% (P > 0.05 for all). (99)Tc(m)N- NOET dual-phase SPECT could be used in differential diagnosis of benign and malignant lung tumors, with no significant differences compared with the efficacy of CT imaging. The semiquantitative indexes (ER, DR and RI) of NOET SPECT can also be used in differential diagnosis of benign and malignant lung tumors, and are not significantly correlated with TNM staging, pathological types, tumor diameter, cavity of the lung tumor mass, history of smoking, tumor size and patient gender.

  12. Loss of lung function after chemo-radiotherapy for NSCLC measured by perfusion SPECT/CT: Correlation with radiation dose and clinical morbidity

    DEFF Research Database (Denmark)

    Farr, Katherina P; Møller, Ditte S; Khalil, Azza A

    2015-01-01

    BACKGROUND: The purpose of the study was to assess dose and time dependence of radiotherapy (RT)-induced changes in regional lung function measured with single photon emission computed tomography (SPECT) of the lung and relate these changes to the symptomatic endpoint of radiation pneumonitis (RP......) in patients treated for non-small cell lung cancer (NSCLC). MATERIAL AND METHODS: NSCLC patients scheduled to receive curative RT of minimum 60 Gy were included prospectively in the study. Lung perfusion SPECT/CT was performed before and three months after RT. Reconstructed SPECT/CT data were registered...

  13. Evaluation of usefulness of thallium-201-SPECT and CT images in differential diagnosis between organizing pneumonia and primary lung cancer

    International Nuclear Information System (INIS)

    Nakamura, Kazuhiko; Fujiwara, Yoshio; Ogawa, Hirofumi; Nakano, Kenji; Ogawa, Toshihide

    2007-01-01

    We tried differential diagnosis between organizing pneumonia and primary lung cancer using CT and 201 Tl single photon emission computed tomography (SPECT) images. CT images were estimated margin, air space consolidation, air bronchogram, ground-glass attenuation, spicula and indentation of the lesions. 201 Tl SPECT images were evaluated early and delayed lesion-to-normal contralateral lung uptake ratio (ER and DR) and retention index (RI). Clearness of margin and ground-glass attenuation of CT images of organizing pneumonia were significant different from those of primary lung cancer. On the other hand, DR and RI of organizing pneumonia were significant lower than those of primary lung cancer. We emphasized that 201 Tl SPECT was useful to evaluate differential diagnosis between organizing pneumonia and primary lung cancer. (author)

  14. Optimisation of quantitative lung SPECT applied to mild COPD: a software phantom simulation study.

    Science.gov (United States)

    Norberg, Pernilla; Olsson, Anna; Alm Carlsson, Gudrun; Sandborg, Michael; Gustafsson, Agnetha

    2015-01-01

    The amount of inhomogeneities in a (99m)Tc Technegas single-photon emission computed tomography (SPECT) lung image, caused by reduced ventilation in lung regions affected by chronic obstructive pulmonary disease (COPD), is correlated to disease advancement. A quantitative analysis method, the CVT method, measuring these inhomogeneities was proposed in earlier work. To detect mild COPD, which is a difficult task, optimised parameter values are needed. In this work, the CVT method was optimised with respect to the parameter values of acquisition, reconstruction and analysis. The ordered subset expectation maximisation (OSEM) algorithm was used for reconstructing the lung SPECT images. As a first step towards clinical application of the CVT method in detecting mild COPD, this study was based on simulated SPECT images of an advanced anthropomorphic lung software phantom including respiratory and cardiac motion, where the mild COPD lung had an overall ventilation reduction of 5%. The best separation between healthy and mild COPD lung images as determined using the CVT measure of ventilation inhomogeneity and 125 MBq (99m)Tc was obtained using a low-energy high-resolution collimator (LEHR) and a power 6 Butterworth post-filter with a cutoff frequency of 0.6 to 0.7 cm(-1). Sixty-four reconstruction updates and a small kernel size should be used when the whole lung is analysed, and for the reduced lung a greater number of updates and a larger kernel size are needed. A LEHR collimator and 125 (99m)Tc MBq together with an optimal combination of cutoff frequency, number of updates and kernel size, gave the best result. Suboptimal selections of either cutoff frequency, number of updates and kernel size will reduce the imaging system's ability to detect mild COPD in the lung phantom.

  15. Prediction of residual lung function after lung surgery, and examination of blood perfusion in the pre- and postoperative lung using three-dimensional SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Shimatani, Shinji [Toho Univ., Tokyo (Japan). School of Medicine

    2001-01-01

    In order to predict postoperative pulmonary function after lung surgery, preoperative {sup 99m}Tc-macroaggregated albumin (MAA) lung perfusion scans with single-photon emission computed tomography (SPECT) were performed. Spirometry was also performed before and 4-6 months after surgery in 40 patients. In addition, changes in blood perfusion in the pre- and postoperative lung were examined by postoperative lung perfusion scans in 18 of the 40 patients. We measured the three-dimensional (3-D) imaging volume of the operative and contralateral lungs using the volumes rendering method at blood perfusion thresholds of 20, 50 and 75%, utilizing {sup 99m}Tc-MAA lung perfusion, and predicted pulmonary function by means of the measured volumes. We examined the correlation between predicted and the measured values of postoperative pulmonary function, forced vital capacity (FVC) and forced expiratory volume in one second (FEV{sub 1.0}). The correlation between FEV{sub 1.0} predicted by SPECT (threshold 50%) and measured postoperative lung function resembled that between lung function predicted by the standard planar method and measured FEV{sub 1.0} in the lobectomy group. We then examined the ratios of both pre- and postoperative blood perfusion volumes obtained using 3-D imaging at lung perfusion threshold ranges of 10% each (PV20-29, PV30-39) to pre- and postoperative total perfusion (PV20-100). In the lobectomy group, the postoperative PV20-29/PV20-100 value was significantly higher for the operative side lung than the preoperative PV20-29/PV20-100 value, and the postoperative PV50-59, 60-69, 70-79, 80-89 and 90-100/PV20-100 values were significantly lower than the respective preoperative values. However, in the contralateral lung, the respective pre- and postoperative PV/PV20-100 values were almost identical. These findings suggest that the rate of low blood perfusion increased while the rate of middle to high perfusion decreased in the lobectomy group in the operative

  16. Prediction of postoperative pulmonary function using 99mTc-MAA perfusion lung SPECT

    International Nuclear Information System (INIS)

    Hosokawa, Nobuyuki; Tanabe, Masatada; Satoh, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Maeda, Masazumi; Tamai, Toyosato; Kojima, Kanji.

    1995-01-01

    In order to predict postoperative pulmonary function, 99m Tc-MAA perfusion lung SPECT and spirometry were performed preoperatively in 52 patients with resectable primary lung cancer; 44 underwent lobectomy, eight pneumonectomy. Local pulmonary function (called local effective volume) was evaluated according to the degree of radionuclide distribution of each voxel in the SPECT images. The total effective volume was defined as the sum of the local effective volume, and the residual effective volume was the total effective volume excluding loss after operation. Predicted pulmonary function (VC and FEV 1.0) was calculated by the following formula: Predicted value=preoperative value x percent of the residual effective volume. Postoperative pulmonary function was predicted in the same patients by means of 99m Tc-MAA perfusion lung planar scintigraphy and X-ray CT. The patients were reinvestigated with spirometry at one and four months after surgery, and the values were compared with the predicted values. The correlations between the predicted values using SPECT and measured postoperative pulmonary function were highly significant (VC: r=0.867, FEV1.0: r=0.864 one month after operation; VC: r=0.860, FEV1.0: r=0.907 4 months after operation). The predicted values calculated using SPECT were accurate compared with the predicted values calculated using planar scintigraphy or X-ray CT. The patients with predicted FEV1.0 of less than 0.8 liter required home oxygen therapy. This method is valuable for the prediction of postoperative pulmonary function before the surgical procedure. (author)

  17. Ventilation/perfusion SPECT in chronic obstructive pulmonary disease: an evaluation by reference to symptoms, spirometric lung function and emphysema, as assessed with HRCT

    Energy Technology Data Exchange (ETDEWEB)

    Joegi, Jonas; Bajc, Marika [Lund University, Skaane University Hospital, Department of Clinical Physiology, Institution of Clinical Sciences, Lund (Sweden); Ekberg, Marie [Lund University, Skaane University Hospital, Department of Respiratory Medicine and Allergology, Institution of Clinical Sciences, Lund (Sweden); Jonson, Bjoern [Lund University, Department of Clinical Physiology, Institution of Clinical Sciences, Lund (Sweden); Bozovic, Gracijela [Lund University, Skaane University Hospital, Department of Radiology, Institution of Clinical Sciences, Lund (Sweden)

    2011-07-15

    Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation which is not fully reversible. Despite the heterogeneity of COPD, its diagnosis and staging is currently based solely on forced expiratory volume in 1 s (FEV{sub 1}). FEV{sub 1} does not explain the underlying pathophysiology of airflow limitation. The relationship between FEV{sub 1}, symptoms and emphysema extent is weak. Better diagnostic tools are needed to define COPD. Tomographic lung scintigraphy [ventilation/perfusion single photon emission tomography (V/P SPECT)] visualizes regional V and P. In COPD, relations between V/P SPECT, spirometry, high-resolution computed tomography (HRCT) and symptoms have been insufficiently studied. The aim of this study was to investigate how lung function imaging and obstructive disease grading undertaken using V/P SPECT correlate with symptoms, spirometric lung function and degree of emphysema assessed with HRCT in patients with COPD. Thirty patients with stable COPD were evaluated with the Medical Research Council dyspnoea questionnaire (MRC) and the clinical COPD questionnaire (CCQ). Spirometry was performed. The extent of emphysema was assessed using HRCT. V/P SPECT was used to assess V/P patterns, total reduction in lung function and degree of obstructive disease. The total reduction in lung function and degree of obstructive disease, assessed with V/P SPECT, significantly correlated with emphysema extent (r = 0.66-0.69, p < 0.0001) and spirometric lung function (r = 0.62-0.74, p < 0.0005). The correlation between emphysema extent and spirometric lung function was weaker. No correlation between MRC, CCQ and objective measurements was found. V/P SPECT is sensitive to early changes in COPD. V/P SPECT also has the possibility to identify comorbid disease. V/P SPECT findings show a significant correlation with emphysema extent and spirometric lung function. We therefore recommend that scintigraphic signs of COPD, whenever found, should be

  18. Ventilation/perfusion SPECT in chronic obstructive pulmonary disease: an evaluation by reference to symptoms, spirometric lung function and emphysema, as assessed with HRCT

    International Nuclear Information System (INIS)

    Joegi, Jonas; Bajc, Marika; Ekberg, Marie; Jonson, Bjoern; Bozovic, Gracijela

    2011-01-01

    Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation which is not fully reversible. Despite the heterogeneity of COPD, its diagnosis and staging is currently based solely on forced expiratory volume in 1 s (FEV 1 ). FEV 1 does not explain the underlying pathophysiology of airflow limitation. The relationship between FEV 1 , symptoms and emphysema extent is weak. Better diagnostic tools are needed to define COPD. Tomographic lung scintigraphy [ventilation/perfusion single photon emission tomography (V/P SPECT)] visualizes regional V and P. In COPD, relations between V/P SPECT, spirometry, high-resolution computed tomography (HRCT) and symptoms have been insufficiently studied. The aim of this study was to investigate how lung function imaging and obstructive disease grading undertaken using V/P SPECT correlate with symptoms, spirometric lung function and degree of emphysema assessed with HRCT in patients with COPD. Thirty patients with stable COPD were evaluated with the Medical Research Council dyspnoea questionnaire (MRC) and the clinical COPD questionnaire (CCQ). Spirometry was performed. The extent of emphysema was assessed using HRCT. V/P SPECT was used to assess V/P patterns, total reduction in lung function and degree of obstructive disease. The total reduction in lung function and degree of obstructive disease, assessed with V/P SPECT, significantly correlated with emphysema extent (r = 0.66-0.69, p < 0.0001) and spirometric lung function (r = 0.62-0.74, p < 0.0005). The correlation between emphysema extent and spirometric lung function was weaker. No correlation between MRC, CCQ and objective measurements was found. V/P SPECT is sensitive to early changes in COPD. V/P SPECT also has the possibility to identify comorbid disease. V/P SPECT findings show a significant correlation with emphysema extent and spirometric lung function. We therefore recommend that scintigraphic signs of COPD, whenever found, should be reported. V

  19. TU-A-12A-02: Novel Lung Ventilation Imaging with Single Energy CT After Single Inhalation of Xenon: Comparison with SPECT Ventilation Images

    Energy Technology Data Exchange (ETDEWEB)

    Negahdar, M [Stanford University School of Medicine, Stanford, CA (United States); Yamamoto, T [UC Davis School of Medicine, Sacramento, CA (United States); Shultz, D; Gable, L; Shan, X; Mittra, E; Loo, B; Maxim, P [Stanford University, Stanford, CA (United States); Diehn, M [Stanford University, Palo Alto, CA (United States)

    2014-06-15

    Purpose: We propose a novel lung functional imaging method to determine the spatial distribution of xenon (Xe) gas in a single inhalation as a measure of regional ventilation. We compare Xe-CT ventilation to single-photon emission CT (SPECT) ventilation, which is the current clinical reference. Regional lung ventilation information may be useful for the diagnosis and monitoring of pulmonary diseases such as COPD, radiotherapy planning, and assessing the progression of toxicity after radiation therapy. Methods: In an IRB-approved clinical study, Xe-CT and SPECT ventilation scans were acquired for three patients including one patient with severe emphysema and two lung cancer patients treated with radiotherapy. For Xe- CT, we acquired two breath-hold single energy CT images of the entire lung with inspiration of 100% O2 and a mixture of 70% Xe and 30% O2, respectively. A video biofeedback system was used to achieve reproducible breath-holds. We used deformable image registration to align the breathhold images with each other to accurately subtract them, producing a map of the distribution of Xe as a surrogate of lung ventilation. We divided each lung into twelve parts and correlated the Hounsfield unit (HU) enhancement at each part with the SPECT ventilation count of the corresponding part of the lung. Results: The mean of the Pearson linear correlation coefficient values between the Xe-CT and ventilation SPECT count for all three patients were 0.62 (p<0.01). The Xe-CT image had a higher resolution than SPECT, and did not show central airway deposition artifacts that were present in the SPECT image. Conclusion: We developed a rapid, safe, clinically practical, and potentially widely accessible method for regional lung functional imaging. We demonstrated strong correlations between the Xe-CT ventilation image and SPECT ventilation image as the clinical reference. This ongoing study will investigate more patients to confirm this finding.

  20. TU-A-12A-02: Novel Lung Ventilation Imaging with Single Energy CT After Single Inhalation of Xenon: Comparison with SPECT Ventilation Images

    International Nuclear Information System (INIS)

    Negahdar, M; Yamamoto, T; Shultz, D; Gable, L; Shan, X; Mittra, E; Loo, B; Maxim, P; Diehn, M

    2014-01-01

    Purpose: We propose a novel lung functional imaging method to determine the spatial distribution of xenon (Xe) gas in a single inhalation as a measure of regional ventilation. We compare Xe-CT ventilation to single-photon emission CT (SPECT) ventilation, which is the current clinical reference. Regional lung ventilation information may be useful for the diagnosis and monitoring of pulmonary diseases such as COPD, radiotherapy planning, and assessing the progression of toxicity after radiation therapy. Methods: In an IRB-approved clinical study, Xe-CT and SPECT ventilation scans were acquired for three patients including one patient with severe emphysema and two lung cancer patients treated with radiotherapy. For Xe- CT, we acquired two breath-hold single energy CT images of the entire lung with inspiration of 100% O2 and a mixture of 70% Xe and 30% O2, respectively. A video biofeedback system was used to achieve reproducible breath-holds. We used deformable image registration to align the breathhold images with each other to accurately subtract them, producing a map of the distribution of Xe as a surrogate of lung ventilation. We divided each lung into twelve parts and correlated the Hounsfield unit (HU) enhancement at each part with the SPECT ventilation count of the corresponding part of the lung. Results: The mean of the Pearson linear correlation coefficient values between the Xe-CT and ventilation SPECT count for all three patients were 0.62 (p<0.01). The Xe-CT image had a higher resolution than SPECT, and did not show central airway deposition artifacts that were present in the SPECT image. Conclusion: We developed a rapid, safe, clinically practical, and potentially widely accessible method for regional lung functional imaging. We demonstrated strong correlations between the Xe-CT ventilation image and SPECT ventilation image as the clinical reference. This ongoing study will investigate more patients to confirm this finding

  1. Role of perfusion SPECT in prediction and measurement of pulmonary complications after radiotherapy for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Farr, Katherina P.; Khalil, Azza A.; Grau, Cai [Aarhus University Hospital, Department of Oncology, Aarhus C (Denmark); Kramer, Stine; Morsing, Anni [Aarhus University Hospital, Department of Nuclear Medicine and PET Centre, Aarhus C (Denmark)

    2015-07-15

    The purpose of the study was to evaluate the ability of baseline perfusion defect score (DS) on SPECT to predict the development of severe symptomatic radiation pneumonitis (RP) and to evaluate changes in perfusion on SPECT as a method of lung perfusion function assessment after curative radiotherapy (RT) for non-small-cell lung cancer (NSCLC). Patients with NSCLC undergoing curative RT were included prospectively. Perfusion SPECT/CT and global pulmonary function tests (PFT) were performed before RT and four times during follow-up. Functional activity on SPECT was measured using a semiquantitative perfusion DS. Pulmonary morbidity was graded by the National Cancer Institute's Common Terminology Criteria for Adverse Events version 4 for pneumonitis. Patients were divided into two groups according to the severity of RP. A total of 71 consecutive patients were included in the study. Baseline DS was associated with chronic obstructive pulmonary disease. A significant inverse correlation was found between baseline DS and forced expiratory volume in 1 s and diffusing capacity of the lung for carbon monoxide. Patients with severe RP had significantly higher baseline total lung DS (mean 5.43) than those with no or mild symptoms (mean DS 3.96, p < 0.01). PFT results were not different between these two groups. The odds ratio for total lung DS was 7.8 (95 % CI 1.9 - 31) demonstrating the ability of this parameter to predict severe RP. Adjustment for other potential confounders known to be associated with increased risk of RP was performed and did not change the odds ratio. The median follow-up time after RT was 8.4 months. The largest DS increase of 13.3 % was associated with severe RP at 3 months of follow-up (p < 0.01). The development of severe RP during follow-up was not associated with changes in PFT results. Perfusion SPECT is a valuable method for predicting severe RP and for assessing changes in regional functional perfusion after curative RT comparable with

  2. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    Science.gov (United States)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  3. The evaluation of the degree of impairment of pulmonary perfusion in lung cancer patients treated by radiotherapy by the quantification of nonuniform distribution of lung perfusion scintigraphy SPECT

    International Nuclear Information System (INIS)

    Mitomo, Osamu; Tsunoda, Takashi; Kuwabara, Hidemasa

    2004-01-01

    By means of quantifying the nonuniform distribution of pulmonary perfusion in Lung Perfusion Scintigraphy SPECT (single photon emission tomography), which is called ''SPECT'' for short, we evaluated the degree of functional impairment of pulmonary perfusion in non-operated lung cancer patients treated by the radiotherapy. Sixty-eight patients with non-operated lung cancer treated with radiotherapy, and who either received or did not receive chemotherapy, from February, 1996 to August, 2002, were examined using SPECT within 6 weeks prior to, or within 2 weeks following radiotherapy. This group was called ''irradiated lung cancer patients''. Twenty-six patients, who were called ''follow-up irradiated lung cancer patients'', were reexamined within four weeks after radiotherapy. On the other hand, 323 patients without lung cancer, who were subdivided into four groups; pulmonary, cardiac, cardio-pulmonary, and non-cardiopulmonary. The SPECT was examined in the supine position after infusing Tc-99m-MAA, 185 MBq in a bolus, mainly into an antecubital vein with the patient's arm elevated. From reconstructed SPECT images, the volume of lung as a whole calculated at 10% of thresholds was assumed to be the ''Baseline Lung Perfusion Volume'' (BPV), and the functional volume rates were calculated in 10% threshold widths from 10% to 100% of the threshold. Assuming the total absolute differences in functional volume rate between each subject and the control to be the distribution index of the lung as a whole (D index), we quantified the degree of nonuniform distribution of the lung as a whole in each subject. In the same way, the distribution index of the left or right lung respectively was calculated as D l or D r index assuming the volume of left or right lung were calculated at 10% of the threshold as left or right BPV and calculating the functional volume rates of each lung in 10% threshold widths from 10% to 100% of the threshold. The D index of irradiated lung cancer

  4. Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

    International Nuclear Information System (INIS)

    Uemura, K.; Toyama, H.; Miyamoto, T.; Yoshikawa, K.; Mori, Y.

    2002-01-01

    Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images. Materials and Methods: Perfusion, ventilation and blood pool images with Tc 99m labeled radiopharmaceuticals and SPECT, tumor images with 11 C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11 C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively. Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was

  5. Clinical value of assays of multiple serum tumor markers in conjunction with 18F-FDG SPECT for discriminating malignant from benign lung disorders

    International Nuclear Information System (INIS)

    Zhang Chunyan; Wang Linglong; Tu Liping; Yu Yuefang; Zhu Weijie; Cai Ao; Gao Shuxing

    2006-01-01

    Objective: To evaluate the clinical value of assays of multiple tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung disorders. Methods: A total of 62 patients with malignant and benign lung diseases un- derwent 18 F-FDG SPECT examination and tests for serum tumor markers CEA, CA50, CA199 and CA242, alone or combined. The sensitivity, specificity, accuracy of these tests were examined. Results: The sensitivity, specificity accuracy of 18 F-FDG SPECT for the diagnosis of malignant lung tumors were 85.7 (30/35), 59.3 (16/27) and 74.2(46/62) respectively, those of each of serum CEA, CA199, CA50, CA242 levels in diagnosing malignant lung tumors were 22.9(8/35), 92.6(25/27), 59.7(33/62), 14.3(5/35), 100(27/27), 51.6 (32/62), 34.3 (12/35), 85.2 (23/27), 56.5 (35/62), 28.6 (10/35), 85.2 (23/27) and 53.2 (33/62) respectively, those of assays of multiple serum tumor markers for diagnosis of malignant lung tumors were 85.7 (30/35), 85.2 (23/27) and 85.5 (53/62) respectively, those of assays of multiple tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung nodules were 88.6(31/35), 85.2(23/27) and 87.1 (54/62) respectively. Conclusion: Assays of multiple serum tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung disorders can yield higher sensitivity, specialty and accuracy, making a significant contribution to clinical application. (authors)

  6. Tc-99m MIBI SPECT in prediction of prognosis in patients with small cell lung cancer

    International Nuclear Information System (INIS)

    Akgun, A.; Cok, G.; Karapolat, I.; Goksel, T.; Burak, Z.

    2006-01-01

    The purpose of this study was to evaluate whether the degree of technetium-99m methoxyisobutylisonitrile (MIBI) uptake and its retention in delayed imaging in small cell lung cancer (SCLC) was correlated with the response to multiagent chemotherapy and to investigate if there was a relationship between the survival time of patients with SCLC and Tc-99m MIBI SPECT tumor uptake parameters at the time of diagnosis. Between 1998 and by December 2004, 40 patients with SCLC were studied with Tc-99m MIBI SPECT at the time of diagnosis. The patients were classified by a follow-up CT as good responders (complete or partial remission) and poor responders (stable disease or progressive disease). Following i.v. administration of 740 MBq Tc-99m MIBI, SPECT imaging at 30 minutes (early) and 2 hours (delayed) was performed. Regions of interests were placed over the tumors and contralateral normal lung tissue on one transverse section. The uptake ratio of the lesion to that in the contralateral normal lung was obtained from early images (early ratio; ER) as well as delayed images (delayed ratio; DR). The retention index (RI%) was measured as: RI%=[(DR-ER)/ER] x 100. Tc-99m MIBI tumor uptake parameters were compared with chemotherapeutic response and survival time. Of 40 patients, 29 patients were good responders (72.5%) and 11 patients were poor responders (27.5%). RI% of Tc-99m MIBI SPECT in the group of good response was significantly higher than in that with poor response (p<0.05). On the other hand, there was no significant difference between the two groups with respect to ER or DR values. Four of 40 patients were still alive with disease (10%). The patient survival time varied from 1 to 70 months (mean survival time=12.9±13.4 months). There was no significant difference between the survival time of patients with respect to ER or DR of Tc-99m MIBI SPECT imaging. When median RI% was accepted as a cut-off value (-3.85%), patients with higher RI% values had a longer survival

  7. Lung scintigraphy

    International Nuclear Information System (INIS)

    Dalenz, Roberto.

    1994-01-01

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies

  8. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  9. Effective avoidance of a functional spect-perfused lung using intensity modulated radiotherapy (IMRT) for non-small cell lung cancer (NSCLC): An update of a planning study

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Singh, Shalini; Christian, Judith A.; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; Bedford, James L.; Brada, Michael

    2009-01-01

    IMRT and 3-dimensional conformal radiotherapy (3-DCRT) plans of 25 patients with non-small cell lung (NSCLC) were compared in terms of planning target volume (PTV) coverage and sparing of functional lung (FL) defined by a SPECT perfusion scan. IMRT resulted in significant reduction of functional V 20 and mean lung dose in stage III patients with inhomogeneous hypoperfusion. If the dose to FL is shown to be the determinant of lung toxicity, IMRT would allow for effective dose escalation by specific avoidance of functional lung.

  10. Pulmonary function-morphologic relationships assessed by SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2012-01-01

    Pulmonary single photon emission computed tomography-computed tomography (SPECT-CT) fusion images provide objective and comprehensive assessment of pulmonary function and morphology relationships at cross-sectional lungs. This article reviewed the noteworthy findings of lung pathophysiology in wide-spectral lung disorders, which have been revealed on SPECT-CT fusion images in 8 years of experience. The fusion images confirmed the fundamental pathophysiologic appearance of lung low CT attenuation caused by airway obstruction-induced hypoxic vasoconstriction and that caused by direct pulmonary arterial obstruction as in acute pulmonary thromboembolism (PTE). The fusion images showed better correlation of lung perfusion distribution with lung CT attenuation changes at lung mosaic CT attenuation (MCA) compared with regional ventilation in the wide-spectral lung disorders, indicating that lung heterogeneous perfusion distribution may be a dominant mechanism of MCA on CT. SPECT-CT angiography fusion images revealed occasional dissociation between lung perfusion defects and intravascular clots in acute PTE, indicating the importance of assessment of actual effect of intravascular colts on peripheral lung perfusion. Perfusion SPECT-CT fusion images revealed the characteristic and preferential location of pulmonary infarction in acute PTE. The fusion images showed occasional unexpected perfusion defects in normal lung areas on CT in chronic obstructive pulmonary diseases and interstitial lung diseases, indicating the ability of perfusion SPECT superior to CT for detection of mild lesions in these disorders. The fusion images showed frequent ''steal phenomenon''-induced perfusion defects extending to the surrounding normal lung of arteriovenous fistulas and those at normal lungs on CT in hepatopulmonary syndrome. Comprehensive assessment of lung function-CT morphology on fusion images will lead to more profound understanding of lung pathophysiology in wide-spectral lung

  11. Lung scintigraphy; Centellograma pulmonar

    Energy Technology Data Exchange (ETDEWEB)

    Dalenz, Roberto

    1994-12-31

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies.

  12. Prediction of postoperative respiratory function of lung cancer patients using 99mTc-MAA SPECT

    International Nuclear Information System (INIS)

    Kokubo, Mitsuharu; Sakai, Satoshi; Miyata, Tomoyuki

    1991-01-01

    In this study, we evaluated the correlation between the predicted postoperative respiratory function using 99m Tc-MAA SPECT with chest CT and the postoperative respiratory function. 99m Tc-MAA SPECT were performed in 10 patients with lung cancer who underwent lobectomy. We measured the fractional loss in the pulmonary flow of the lobe to be resected using 99m Tc-MAA SPECT with chest CT. The value of predicted postoperative respiratory function was measured as follows: the value of predicted postoperative respiratory function=the value of preoperative respiratory function x (1-the fractional loss in the pulmonary flow of the lobe to be resected). Postoperative forced vital capacity (FVC), forced expiratory volume in the first second (FEV 1.0 ) and % vital capacity (%VC) were predicted in this study, and were compared to the respiratory function at three months and six months after operation. The predicted postoperative respiratory function was highly correlated with the actually observed postoperative respiratory function. (author)

  13. Relationship between the optimum cut off frequency for Butter worth filter and lung-heart ratio in 99mTc myocardial SPECT

    International Nuclear Information System (INIS)

    Salihin Yusoff, M. N.; Zakaria, A.

    2010-01-01

    We investigated whether the lung-heart ratio parameter can be used to identify the optimum cut off frequency for Butter worth filter in 99m Tc myocardial SPECT imaging. Materials and Methods: This study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99m Tc concentration. The cardiac insert was then put into a cylindrical tank which filled with six different 99m Tc concentrations as background. Thus, six target background concentrations ratios (T/B) were carried out. The lung-heart ratio was determined for every SPECT raw image obtained corresponding to each T/B. Then, 130 different combinations of filter parameters from Butter worth filter were utilized to reconstruct each SPECT raw image. The determination of count in myocardium, background, and defect regions of interest were performed for every reconstructed image. All the count values were then used to calculate contrast, signal-to-noise ratio, and defect size. Each criterion was graded (1 to 100) and then summed together to obtain total grade. The optimum cut off frequency for each lung-heart ratio was determined from the total grade. The relation between optimum cut off frequency for Butter worth filter and lung-heart ratio was established using linear regression. Results: There were good relationship between the optimum Butter worth cut off frequency and lung-heart ratio (R 2 = 0.864, p<0.01). The optimal cut off frequency correspond to the change in lung-heart ratio can be expressed by the equation: Optimum cut off frequency=0.715*lung-heart ratio + 0.227. Conclusion: This study suggests that the optimum cut off frequency for Butter worth filter should be determined by referring to lung-heart ratio in each patient study.

  14. SPECT/CT in patients with painful knee arthroplasty - what is the evidence?

    International Nuclear Information System (INIS)

    Hirschmann, Michael T.; Henckel, Johann; Rasch, Helmut

    2013-01-01

    SPECT/CT is increasingly recognized as a promising imaging modality for the investigation of patients with a painful knee after knee arthroplasty. In this review article, we give an overview of the clinical value and current and future applications of SPECT/CT for patients with knee pain following joint arthroplasty. A detailed evidence-based literature review is performed and presented. (orig.)

  15. SPECT/CT in patients with painful knee arthroplasty - what is the evidence?

    Energy Technology Data Exchange (ETDEWEB)

    Hirschmann, Michael T. [Kantonsspital Baselland-Bruderholz, Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland); Henckel, Johann [Imperial College London, London (United Kingdom); Rasch, Helmut [Kantonsspital Baselland-Bruderholz, Institute for Radiology and Nuclear Medicine, Bruderholz (Switzerland)

    2013-09-15

    SPECT/CT is increasingly recognized as a promising imaging modality for the investigation of patients with a painful knee after knee arthroplasty. In this review article, we give an overview of the clinical value and current and future applications of SPECT/CT for patients with knee pain following joint arthroplasty. A detailed evidence-based literature review is performed and presented. (orig.)

  16. A potential to reduce pulmonary toxicity: The use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Christian, Judith A.; Partridge, Mike; Niotsikou, Elena; Cook, Gary; Parker, Michelle; Bedford, James L.; Brada, Michael

    2007-01-01

    Background and purpose: The study aimed to examine specific avoidance of functional lung (FL) defined by a single photon emission computerized tomography (SPECT) lung perfusion scan, using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3-DCRT) in patients with non-small cell lung cancer (NSCLC). Materials and methods: Patients with NSCLC underwent planning computerized tomography (CT) and lung perfusion SPECT scan in the treatment position using fiducial markers to allow co-registration in the treatment planning system. Radiotherapy (RT) volumes were delineated on the CT scan. FL was defined using co-registered SPECT images. Two inverse coplanar RT plans were generated for each patient: 4-field 3-DCRT and 5-field step-and-shoot IMRT. 3-DCRT plans were created using automated AutoPlan optimisation software, and IMRT plans were generated employing Pinnacle 3 treatment planning system (Philips Radiation Oncology Systems). All plans were prescribed to 64 Gy in 32 fractions using data for the 6 MV beam from an Elekta linear accelerator. The objectives for both plans were to minimize the volume of FL irradiated to 20 Gy (fV 20 ) and dose variation within the planning target volume (PTV). A spinal cord dose was constrained to 46 Gy. Volume of PTV receiving 90% of the prescribed dose (PTV 90 ), fV 20 , and functional mean lung dose (fMLD) were recorded. The PTV 90 /fV 20 ratio was used to account for variations in both measures, where a higher value represented a better plan. Results: Thirty-four RT plans of 17 patients with stage I-IIIB NSCLC suitable for radical RT were analysed. In 6 patients with stage I-II disease there was no improvement in PTV 90 , fV 20 , PTV/fV 20 ratio and fMLD using IMRT compared to 3-DCRT. In 11 patients with stage IIIA-B disease, the PTV was equally well covered with IMRT and 3-DCRT plans, with IMRT producing better PTV 90 /fV 20 ratio (mean ratio - 7.2 vs. 5.3, respectively, p = 0.001) and reduced f

  17. Retention index of thallium-201 single photon emission computerised tomography (SPECT) as an indicator of metastasis in adenocarcinoma of the lung.

    Science.gov (United States)

    Takekawa, H.; Itoh, K.; Abe, S.; Ogura, S.; Isobe, H.; Sukou, N.; Furudate, M.; Kawakami, Y.

    1994-01-01

    We examined the relationship between the retention of thallium-201 (201Tl) on a delayed scan and the metastatic potential of adenocarcinomas of the lung. We studied 43 patients with adenocarcinoma of the lung and divided them into two groups according to the presence or absence of lymph node metastasis. 201Tl single photon emission computerised tomography (SPECT) was conducted twice: 15 min (early scan) and 120 min (delayed scan) after intravenous injection of 3 mCi of 201Tl chloride. We calculated the retention index in order to evaluate the degree of 201Tl retention in the primary tumour. The retention indices were significantly higher in the group that was positive for lymph node metastasis than in the negative group. In adenocarcinomas with high metastatic potential, 201Tl SPECT demonstrated slow washout or increased retention on the delayed scan. The retention index of 201Tl SPECT is a useful indicator of metastatic potential, thereby facilitating the prediction of prognosis, and provides insight into the relationship between 201Tl uptake and malignancy. This is the first report demonstrating a significant relationship between the retention of 201Tl SPECT and lymph node metastasis. Images Figure 1 PMID:8054281

  18. 99mTc-MIBI SPECT in small call lung cancer patients before chemotherapy and after unresponsive chemotherapy

    International Nuclear Information System (INIS)

    Yamamoto, Yuka; Nishiyama, Yoshihiro; Fukunaga, Kotaro; Satoh, Katashi; Fujita, Jiro; Ohkawa, Motoomi

    2001-01-01

    We evaluated the accumulation of 99m Tc-MIBI in small cell lung cancer patients before chemotherapy and after unresponsive chemotherapy. The pre-chemotherapeutic group included 22 newly diagnosed patients. These patients underwent a 99m Tc-MIBI SPECT study before starting chemotherapy. After chemotherapy, based on changes in tumor size, three different patterns of response (complete remission: CR, partial remission: PR and no change: NC) were defined. The post-chemotherapeutic group included 11 patients after chemotherapy who did not respond to chemotherapy. These patients underwent a 99m Tc-MIBI SPECT study after completion of chemotherapy. SPECT images were acquired 15 min (early) and 2 hr (delayed) after injection of 99m Tc-MIBI. With a region of interest technique, the early ratio, delayed ratio and retention index were calculated. Early and delayed ratios in pre-chemotherapeutic patients were significantly higher than those in post-chemotherapeutic patients. There were no significant differences between the pre-chemotherapeutic and post-chemotherapeutic patients in the retention index. In the pre-chemotherapeutic patients, early and delayed ratios for the CR and PR groups were significantly higher than those for the NC group. There were no significant differences in the retention index with respect to the tumor response. 99m Tc-MIBI might be useful for evaluating the tumor chemosensitivity in patients with small cell lung cancer. (author)

  19. Clinical evaluation of 99mTc-Technegas SPECT in thoracoscopic lung volume reduction surgery in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Imai, Teruhiko; Sasaki, Yoshiaki; Shinkai, Takayuki

    2000-01-01

    99m Tc-Technegas (Tcgas) SPECT is useful for evaluating the patency of the airway and highly sensitive in detecting regional pulmonary function in pulmonary emphysema. The aim of this study is to evaluate regional ventilation impairment by this method pre and post thoracoscopic lung volume reduction surgery (LVRS) in patients with pulmonary emphysema. There were 11 patients with pulmonary emphysema. The mean age of patients was 64.1 years. All patients were males. LVRS was performed bilaterally in 8 patients and unilaterally in 3 patients. Post inhalation of Tcgas in the sitting position, the subjects were placed in the supine position and SPECT was performed. Distribution of Tcgas on axial images was classified into 4 types, homogeneous, inhomogeneous, hot spot, and defect. Three slices of axial SPECT images, the upper, middle and lower fields were selected, and changes in deposition patterns post LVRS were scored (Tcgas score). Post LVRS, dyspnea on exertion and pulmonary function tests were improved. Pre LVRS, inhomogeneous distribution, hot spots and defects were observed in all patients. Post LVRS, improvement in distribution was obtained not only in the surgical field and other fields, but also in the contralateral lung of unilaterally operated patients. In 5 patients some fields showed deterioration. The Tcgas score correlated with improvements in FEV 1.0 , FEV 1.0 % and %FEV 1.0 . Tcgas SPECT is useful for evaluating changes in regional pulmonary function post LVRS. (author)

  20. The influence of gravity on regional lung blood flow in humans: SPECT in the upright and head-down posture.

    Science.gov (United States)

    Ax, M; Sanchez-Crespo, A; Lindahl, S G E; Mure, M; Petersson, J

    2017-06-01

    Previous studies in humans have shown that gravity has little influence on the distribution of lung blood flow while changing posture from supine to prone. This study aimed to evaluate the maximal influence of posture by comparison of regional lung blood flow in the upright and head-down posture in 8 healthy volunteers, using a tilt table. Regional lung blood flow was marked by intravenous injection of macroaggregates of human albumin labeled with 99m Tc or 113m In, in the upright and head-down posture, respectively, during tidal breathing. Both radiotracers remain fixed in the lung after administration. The distribution of radioactivity was mapped using quantitative single photon emission computed tomography (SPECT) corrected for attenuation and scatter. All images were obtained supine during tidal breathing. A shift from upright to the head-down posture caused a clear redistribution of blood flow from basal to apical regions. We conclude that posture plays a role for the distribution of lung blood flow in upright humans, and that the influence of posture, and thereby gravity, is much greater in the upright and head-down posture than in horizontal postures. However, the results of the study demonstrate that lung structure is the main determinant of regional blood flow and gravity is a secondary contributor to the distribution of lung blood flow in the upright and head-down positions. NEW & NOTEWORTHY Using a dual-isotope quantitative SPECT method, we demonstrated that although a shift in posture redistributes blood flow in the direction of gravity, the results are also consistent with lung structure being a greater determinant of regional blood flow than gravity. To our knowledge, this is the first study to use modern imaging methods to quantify the shift in regional lung blood flow in humans at a change between the upright and head-down postures. Copyright © 2017 the American Physiological Society.

  1. Lung Perfusion SPECT: Application in a Patient With Tetralogy of Fallot and Suspected Pulmonary Thromboemboli

    International Nuclear Information System (INIS)

    Ranji Amjad, Mina; Abbasi, Mehrshad; Farzanehfar, Saeed

    2015-01-01

    A 22-year-old woman presented with acute left-sided pleuritic chest pain and dyspnea 6 days after surgery for revision of the stenotic central aortopulmonary shunt. She had a history of tetralogy of Fallot (TOF), pulmonary valve stenosis, ventricular septal defect and major aortopulmonary collateral artery. Her Waterston shunt was placed when she was 5 years old and stented and re-dilated after stenosis. Acute pulmonary thromboemboli (PTE) was suspected and pulmonary perfusion scan was performed with 4 mCi 99m Technetium labeled macroaggregated albumin. The left lung was globally hypoperfused with evident uptake in the brain, renal parenchyma and thyroid. SPECT images revealed a segmental wedge-shaped peripheral defect in the posterior segment of the left upper lobe. The scan was interpreted as acute/chronic PTE or vascular abnormality. CT angiography excluded PTE; nevertheless the patient was treated with a therapeutic dose of heparin changed to warfarin and was discharged with improvement of the symptoms. Pulmonary artery angiography was not performed

  2. Association Between RT-Induced Changes in Lung Tissue Density and Global Lung Function

    International Nuclear Information System (INIS)

    Ma Jinli; Zhang Junan; Zhou Sumin; Hubbs, Jessica L.; Foltz, Rodney J.; Hollis, Donna R.; Light, Kim L.; Wong, Terence Z.; Kelsey, Christopher R.; Marks, Lawrence B.

    2009-01-01

    Purpose: To assess the association between radiotherapy (RT)-induced changes in computed tomography (CT)-defined lung tissue density and pulmonary function tests (PFTs). Methods and Materials: Patients undergoing incidental partial lung RT were prospectively assessed for global (PFTs) and regional (CT and single photon emission CT [SPECT]) lung function before and, serially, after RT. The percent reductions in the PFT and the average changes in lung density were compared (Pearson correlations) in the overall group and subgroups stratified according to various clinical factors. Comparisons were also made between the CT- and SPECT-based computations using the Mann-Whitney U test. Results: Between 1991 and 2004, 343 patients were enrolled in this study. Of these, 111 patients had a total of 203 concurrent post-RT evaluations of changes in lung density and PFTs available for the analyses, and 81 patients had a total of 141 concurrent post-RT SPECT images. The average increases in lung density were related to the percent reductions in the PFTs, albeit with modest correlation coefficients (range, 0.20-0.43). The analyses also indicated that the association between lung density and PFT changes is essentially equivalent to the corresponding association with SPECT-defined lung perfusion. Conclusion: We found a weak quantitative association between the degree of increase in lung density as defined by CT and the percent reduction in the PFTs.

  3. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Iwanaga, Hideyuki; Hayashi, Noriko; Seto, Akiko; Matsunaga, Naofumi

    2008-01-01

    Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P<0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P<0.05). DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease. (author)

  4. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  5. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    radiolabeled liquid aerosols are not restricted to the presence of obstructive lung disease. Radiolabeled macroaggregated human albumin is the imaging agent of choice for perfusion scintigraphy. An optimal combination of nuclide activities and acquisition times for ventilation and perfusion, collimators......Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas over......, and imaging matrix yields an adequate V/Q SPECT study in approximately 20 minutes of imaging time. The recommended protocol based on the patient remaining in an unchanged position during the initial ventilation study and the perfusion study allows presentation of matching ventilation and perfusion slices...

  6. State-of-the-art radiological techniques improve the assessment of postoperative lung function in patients with non-small cell lung cancer

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Takenaka, Daisuke; Onishi, Yumiko; Matsumoto, Keiko; Matsumoto, Sumiaki; Maniwa, Yoshimasa; Yoshimura, Masahiro; Nishimura, Yoshihiro; Sugimura, Kazuro

    2011-01-01

    Purpose: The purpose of this study was to compare predictive capabilities for postoperative lung function in non-small cell lung cancer (NSCLC) patients of the state-of-the-art radiological methods including perfusion MRI, quantitative CT and SPECT/CT with that of anatomical method (i.e. qualitative CT) and traditional nuclear medicine methods such as planar imaging and SPECT. Materials and methods: Perfusion MRI, CT, nuclear medicine study and measurements of %FEV 1 before and after lung resection were performed for 229 NSCLC patients (125 men and 104 women). For perfusion MRI, postoperative %FEV 1 (po%FEV 1 ) was predicted from semi-quantitatively assessed blood volumes within total and resected lungs, for quantitative CT, it was predicted from the functional lung volumes within total and resected lungs, for qualitative CT, from the number of segments of total and resected lungs, and for nuclear medicine studies, from uptakes within total and resected lungs. All SPECTs were automatically co-registered with CTs for preparation of SPECT/CTs. Predicted po%FEV 1 s were then correlated with actual po%FEV 1 s, which were measured %FEV 1 s after operation. The limits of agreement were also evaluated. Results: All predicted po%FEV 1 s showed good correlation with actual po%FEV 1 s (0.83 ≤ r ≤ 0.88, p < 0.0001). Perfusion MRI, quantitative CT and SPECT/CT demonstrated better correlation than other methods. The limits of agreement of perfusion MRI (4.4 ± 14.2%), quantitative CT (4.7 ± 14.2%) and SPECT/CT (5.1 ± 14.7%) were less than those of qualitative CT (6.0 ± 17.4%), planar imaging (5.8 ± 18.2%), and SPECT (5.5 ± 16.8%). Conclusions: State-of-the-art radiological methods can predict postoperative lung function in NSCLC patients more accurately than traditional methods.

  7. State-of-the-art radiological techniques improve the assessment of postoperative lung function in patients with non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yoshiharuohno@aol.com [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2 Minatojima Minami-machi, Chuo-ku, Kobe, Hyogo, 650-0047 (Japan); Takenaka, Daisuke; Onishi, Yumiko; Matsumoto, Keiko; Matsumoto, Sumiaki [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Maniwa, Yoshimasa [Division of Cardiovascular, Thoracic and Pediatric Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Yoshimura, Masahiro [Division of Cardiovascular, Thoracic and Pediatric Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Division of Thoracic Surgery, Hyogo Cancer Center, 13-7 Kitaohji-cho, Akashi, Hyogo, 673-8558 (Japan); Nishimura, Yoshihiro [Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2011-01-15

    Purpose: The purpose of this study was to compare predictive capabilities for postoperative lung function in non-small cell lung cancer (NSCLC) patients of the state-of-the-art radiological methods including perfusion MRI, quantitative CT and SPECT/CT with that of anatomical method (i.e. qualitative CT) and traditional nuclear medicine methods such as planar imaging and SPECT. Materials and methods: Perfusion MRI, CT, nuclear medicine study and measurements of %FEV{sub 1} before and after lung resection were performed for 229 NSCLC patients (125 men and 104 women). For perfusion MRI, postoperative %FEV{sub 1} (po%FEV{sub 1}) was predicted from semi-quantitatively assessed blood volumes within total and resected lungs, for quantitative CT, it was predicted from the functional lung volumes within total and resected lungs, for qualitative CT, from the number of segments of total and resected lungs, and for nuclear medicine studies, from uptakes within total and resected lungs. All SPECTs were automatically co-registered with CTs for preparation of SPECT/CTs. Predicted po%FEV{sub 1}s were then correlated with actual po%FEV{sub 1}s, which were measured %FEV{sub 1}s after operation. The limits of agreement were also evaluated. Results: All predicted po%FEV{sub 1}s showed good correlation with actual po%FEV{sub 1}s (0.83 {<=} r {<=} 0.88, p < 0.0001). Perfusion MRI, quantitative CT and SPECT/CT demonstrated better correlation than other methods. The limits of agreement of perfusion MRI (4.4 {+-} 14.2%), quantitative CT (4.7 {+-} 14.2%) and SPECT/CT (5.1 {+-} 14.7%) were less than those of qualitative CT (6.0 {+-} 17.4%), planar imaging (5.8 {+-} 18.2%), and SPECT (5.5 {+-} 16.8%). Conclusions: State-of-the-art radiological methods can predict postoperative lung function in NSCLC patients more accurately than traditional methods.

  8. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  9. [Lung scintigraphy].

    Science.gov (United States)

    Schümichen, Carl; Schmidt, Matthias; Krause, Thomas

    2018-06-01

    The S1 guideline for lung scintigraphy has been updated and extended in order to emphasize the advantages oft the method in detecting acute pulmonary embolism (PE) in the periphery oft the lung (subsegmental PE), in underlying subacute and chronic pulmonary disorders, as well as in detecting chronic LE (CTEPH). Method of choice is ventilation / perfusion (V/P) SPECT or V/P SPECT/CT with even higher specificity. Because of its high sensitivity, a threshold (V/P mismatch in at least one segment or two subsegments) is introduced to avoid overtreatment. In case of a change in the therapeutic approach (observation only instead of anticoaculation) the threshold can be omitted. New data concerning the clinical and therapeutical impact of subsegmental PE are included, the chapters open questions have been extented. Other indications for V/P SPECT (secondary diagnoses, abnormalities in pulmonary perfusion, prediction of postoperative lung function) are presented with new data. Schattauer GmbH.

  10. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas ov...

  11. (99m)Tc-3PRGD 2 SPECT/CT predicts the outcome of advanced nonsquamous non-small cell lung cancer receiving chemoradiotherapy plus bevacizumab.

    Science.gov (United States)

    Ma, Qingjie; Min, Kaiyin; Wang, Ting; Chen, Bin; Wen, Qiang; Wang, Fan; Ji, Tiefeng; Gao, Shi

    2015-07-01

    Functional imaging can help clinicians assess the individual response of advanced nonsquamous non-small cell lung cancer (NSCLC) to chemoradiation therapy plus bevacizumab. Our purpose is to investigate the ability of (99m)Tc-3PRGD2 single photon emission computed tomography/computed tomography (SPECT/CT) in predicting the early response to treatment. Patients with advanced nonsquamous NSCLC diagnosed by histological or cytological examination were imaged with (99m)Tc-3PRGD2 SPECT/CT at 3 time points: 1-3 days before the start of treatment (SPECT1), 40 Gy radiotherapy with 2 cycles of chemotherapy plus bevacizumab (SPECT2) and 4 weeks after chemoradiotherapy plus bevacizumab (SPECT3). The images were evaluated semiquantitatively by measuring the tumor to non-tumor ratio (T/N) and calculating the percentage change in T/N ratio. Short-term outcome was assessed by the treatment response evaluation according to the Response Evaluation Criteria in Solid Tumors criteria as: complete response (CR), partial response (PR), stable disease (SD) and progressive disease (PD). Patients were divided two groups: responders (CR and PR) and nonresponders (SD and PD). To determine a threshold for percent reduction in T/N ratios, receiver-operating characteristic (ROC) curve analysis was used. Patients were grouped again based on the threshold of P1 (the change percentage from SPECT1 to SPECT2) and P2 (the change percentage from SPECT1 to SPECT3): P1 responders and P1 nonresponders; P2 responders and P2 nonresponders. Patients were followed up starting 4 weeks after completion of therapy and then every 3 months for the first 2 years and every 6 months after 2 years. OS of P1 responders, P1 nonresponders, P2 responders and P2 nonresponders was estimated and graphically illustrated using the Kaplan-Meier method and the log-rank test was used to test the null hypotheses of equal OS in subgroups of patients. A total of 28 patients completed all imaging and treatment. All primary

  12. Assessment of smoking-induced impairment of pulmonary perfusion using three-dimensional SPECT images

    Energy Technology Data Exchange (ETDEWEB)

    Miyasaka, Takashi [Toho Univ., Tokyo (Japan). School of Medicine

    1997-09-01

    The effects of smoking on ventilation-perfusion lung scintigrams were investigated. The subjects comprised 40 healthy males (28 smokers and 12 nonsmokers) without a history of cardiopulmonary disease and with normal chest radiographs. After acquisition of planar images of ventilation lung scintigrams with 370 MBq of {sup 133}Xe gas, planar images and SPECT images of pulmonary perfusion flow were obtained using 185 MBq of {sup 99m}Tc-MAA. Planar imaging showed perfusion defects in only 5 smokers. In contrast, 16 subjects were found to have perfusion defects on SPECT images (p<0.05), indicating the usefulness of SPECT images in detecting minor vascular damage of the lung. Although perfusion defects were common in the smokers (p<0.05), their relationship to the BRINKMAN index was uncertain. The perfusion defects found in the smokers were nonsegmental and commonly involved the right upper lobe. Ventilation scans revealed only delayed washout of {sup 133}Xe in 4 smokers, suggesting that smoking-induced abnormal perfusion on SPECT appears earlier than impaired ventilation on scintigrams. (author)

  13. Clinical assessment of SPECT/CT co-registration image fusion

    International Nuclear Information System (INIS)

    Zhou Wen; Luan Zhaosheng; Peng Yong

    2004-01-01

    Objective: Study the methodology of the SPECT/CT co-registration image fusion, and Assessment the Clinical application value. Method: 172 patients who underwent SPECT/CT image fusion during 2001-2003 were studied, 119 men, 53 women. 51 patients underwent 18FDG image +CT, 26 patients underwent 99m Tc-RBC Liver pool image +CT, 43 patients underwent 99mTc-MDP Bone image +CT, 18 patients underwent 99m Tc-MAA Lung perfusion image +CT. The machine is Millium VG SPECT of GE Company. All patients have been taken three steps image: X-ray survey, X-ray transmission and nuclear emission image (Including planer imaging, SPECT or 18 F-FDG of dual head camera) without changing the position of the patients. We reconstruct the emission image with X-ray map and do reconstruction, 18FDG with COSEM and 99mTc with OSEM. Then combine the transmission image and the reconstructed emission image. We use different process parameters in deferent image methods. The accurate rate of SPECT/CT image fusion were statistics, and compare their accurate with that of single nuclear emission image. Results: The nuclear image which have been reconstructed by X-ray attenuation and OSEM are apparent better than pre-reconstructed. The post-reconstructed emission images have no scatter lines around the organs. The outline between different issues is more clear than before. The validity of All post-reconstructed images is better than pre-reconstructed. SPECT/CT image fusion make localization have worthy bases. 138 patients, the accuracy of SPECT/CT image fusion is 91.3% (126/138), whereas 60(88.2%) were found through SPECT/CT image fusion, There are significant difference between them(P 99m Tc- RBC-SPECT +CT image fusion, but 21 of them were inspected by emission image. In BONE 99m Tc -MDP-SPECT +CT image fusion, 4 patients' removed bone(1-6 months after surgery) and their relay with normal bone had activity, their morphologic and density in CT were different from normal bones. 11 of 20 patients who could

  14. Hyperpolarized 3He MRI and 81mKr SPECT in chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Stavngaard, Trine; Søgaard, Lise; Mortensen, J

    2005-01-01

    visual defect score (r=0.80, pemphysema (pulmonary function test and HRCT). The defect scores were largest on 81mKr SPECT (the score on HP 3He MRI...... was to compare ventilation imaging methods in 26 patients with chronic obstructive pulmonary disease (COPD) and nine lung healthy volunteers. METHODS: HP 3He MRI, 81mKr single-photon emission computed tomography (SPECT), high-resolution computed tomography (HRCT) and pulmonary function tests were performed....... The three scans were scored visually as percentage of non-ventilated/diseased lung, and a computer-based objective measure of the ventilated volume in HP 3He MRI and 81mKr SPECT and an emphysema index in HRCT were calculated. RESULTS: We found a good correlation between HP 3He MRI and 81mKr SPECT for both...

  15. Practical reconstruction protocol for quantitative 90Y bremsstrahlung SPECT/CT

    International Nuclear Information System (INIS)

    Siman, W.; Mikell, J. K.; Kappadath, S. C.

    2016-01-01

    Purpose: To develop a practical background compensation (BC) technique to improve quantitative 90 Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a 90 Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar 90 Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical 90 Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for 90 Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity

  16. Comparison between high-resolution computed tomography and 99mTc-technegas SPECT pulmonary emphysema

    International Nuclear Information System (INIS)

    Nakano, Satoru; Satoh, Katashi; Takahashi, Kazue

    1996-01-01

    Scintigraphy with 99m Tc-technegas was recently introduced for clinical imaging of lung ventilation. This method has been found to be useful in emergencies, to be more suitable for single photon emission computed tomography (SPECT) than other agents used in ventilation scintigraphy, and could reveal abnormalities in ventilation more easily than high resolution computed tomography (HRCT) in pulmonary emphysema. We compared 99m Tc-technegas SPECT with HRCT in six regions: the right upper, middle, and lower lobes, the left upper lobe, the lingula, and the left lower lobe, in 15 patients with pulmonary emphysema. Patients with centrilobular emphysema tended to show stronger changes in upper lobes than in lower lobes on both 99m Tc-technegas SPECT and HRCT. Some regions showed no change on HRCT but various changes on 99m Tc-SPECT. Patients with panlobular emphysema showed severe changes on 99m Tc-SPECT in lower lung fields in which well-demarcated areas of low attenuation were not seen on HRCT. We conclude that 99m Tc-SPECT is useful for detecting early changes and panlobular changes in pulmonary emphysema. (author)

  17. Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Siman, W.; Mikell, J. K.; Kappadath, S. C., E-mail: skappadath@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas 77030 (United States)

    2016-09-15

    Purpose: To develop a practical background compensation (BC) technique to improve quantitative {sup 90}Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a {sup 90}Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar {sup 90}Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical {sup 90}Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for {sup 90}Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion

  18. Infective endocarditis detection through SPECT/CT images digital processing

    Science.gov (United States)

    Moreno, Albino; Valdés, Raquel; Jiménez, Luis; Vallejo, Enrique; Hernández, Salvador; Soto, Gabriel

    2014-03-01

    Infective endocarditis (IE) is a difficult-to-diagnose pathology, since its manifestation in patients is highly variable. In this work, it was proposed a semiautomatic algorithm based on SPECT images digital processing for the detection of IE using a CT images volume as a spatial reference. The heart/lung rate was calculated using the SPECT images information. There were no statistically significant differences between the heart/lung rates values of a group of patients diagnosed with IE (2.62+/-0.47) and a group of healthy or control subjects (2.84+/-0.68). However, it is necessary to increase the study sample of both the individuals diagnosed with IE and the control group subjects, as well as to improve the images quality.

  19. Estimation of lung volume and pulmonary blood volume from radioisotopic images

    International Nuclear Information System (INIS)

    Kanazawa, Minoru

    1989-01-01

    Lung volume and pulmonary blood volume in man were estimated from the radioisotopic image using single photon emission computed tomography (SPECT). Six healthy volunteers were studied in a supine position with normal and altered lung volumes by applying continuous negative body-surface pressure (CNP) and by positive end-expiratory pressure (PEEP). 99m Tc labeled human serum albumin was administered as an aerosol to image the lungs. The CNP caused the diaphragm to be lowered and it increased the mean lung tissue volume obtained by SPECT from 3.09±0.49 l for baseline to 3.67±0.62 l for 10 cmH 2 O (p 2 O (p 2 O), respectively. The PEEP also increased the lung tissue volume to 3.68±0.68 l for 10 cmH 2 O as compared with the baseline (p 2 O PEEP. The lung tissue volume obtained by SPECT showed a positive correlation with functional residual capacity measured by the He dilution method (r=0.91, p 99m Tc-labeled red blood cells. The L/H ratio decreased after either the CNP or PEEP, suggesting a decrease in the blood volume per unit lung volume. However, it was suggested that the total pulmonary blood volume increased slightly either on the CNP (+7.4% for 10 cmH 2 O, p 2 O,p<0.05) when we extrapolated the L/H ratio to the whole lungs by multiplying the lung tissue volume obtained by SPECT. We concluded that SPECT could offer access to the estimation of lung volume and pulmonary blood volume in vivo. (author)

  20. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Kasper, S.; Gruenwald, F.; Walter, H.; Klemm, E.; Podreka, I.; Biersack, H.J.

    1994-01-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [de

  1. SPECT in psychiatry; Die Bedeutung der Hirn-SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Kasper, S [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Gruenwald, F [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Danos, P [Psychiatrische Universitaetsklinik, Bonn (Germany); Walter, H [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Klemm, E [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Bruecke, T [Universitaetsklinik fuer Neurologie, Wien (Austria); Podreka, I [Universitaetsklinik fuer Neurologie, Wien (Austria); Biersack, H J [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin

    1994-10-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [Deutsch] In den vergangenen 15 Jahren wurde durch verschiedene methodologische Ansaetze versucht, die biologischen Ursachen psychiatrischer Erkrankungen naeher zu erforschen. Als eine bedeutende Methode hat sich dabei die Single-Photonen-Emissions-Computertomographie (SPECT) herausgestellt. Waehrend die SPECT-Untersuchungen bereits Eingang in die Routinediagnostik bei Demenzen vom Alzheimer-Typ gefunden haben, konnten fuer weitere psychiatrische Erkrankungen noch keine eindeutigen Befunde etabliert werden. Mit der SPECT-Methode ist es jedoch gelungen, funktionelle Veraenderungen des Gehirns von psychiatrischen Erkrankungen darzustellen, wie z.B. Schizophrenie, Depression, Angsterkrankungen bzw. Substanzmissbrauch. In Forschungsprotokollen wird durch die SPECT-Methode versucht, abzuklaeren, inwieweit es moeglich ist, innerhalb der Erkrankungsentitaeten psychiatrischer Erkrankungen oder auch diese uebergreifend eine Subklassifizierung zu finden und evtl. Gehirnsysteme ausfindig zu machen, die mit einer spezifischen

  2. Powerful functional imaging of respiratory nuclear medicine. Is CT imaging alone really sufficient for diagnosis and pathophysiologic assessment of lung diseases?

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2010-01-01

    Ventilation (V)-perfusion (Q) single photon emission computed tomography (SPECT) provides important information of functional impairment in various lung diseases, and often sensitively detects CT-undetectable lesions. V·Q SPECT also provides objective and quantitative assessment of severity of lung functional impairment. Functional-morphological correlation on V·Q SPECT-CT fusion images further facilitates these advantages of V·Q SPECT. This article describes clinical feasibility of V·Q SPECT in functional assessment and diagnosis of chronic obstructive pulmonary diseases, pulmonary embolism, pulmonary hypertension, interstitial lung diseases, and lung right-to-left shunt diseases. This article hopefully provides sufficient responses to the crucial query of ''Is CT imaging alone really sufficient for diagnosis and pathophysiological assessment of various lung diseases?'' (author)

  3. Effective of deep breath-hold SPECT in torso area. Examination concerning improvement of resolution

    International Nuclear Information System (INIS)

    Kawai, Takashi; Horiuchi, Shoji; Hayashi, Masuo; Sugibayashi, Keiichi

    2007-01-01

    The routine single photon emission computed tomography (SPECT) gives images with reduced resolution of internal organs like diaphragm due to breathing movements. In the present study, authors developed a breath-hold (BH) SPECT method where SPECT projection data were acquired during BH, and examined its usefulness. Equipments used were all Toshiba's dual-detector SPECT system E.CAM, image processor GMS-5500 A/PI, fusion software ART, and CT scanner Aquillion/M8. SPECT data were alternatively acquired at steps during BH and free breath (FB), for an entire step-and-shoot SPECT cycle, and acquisition time for 1 step (view) was set to be 10-15 sec depending on the subject's BH ability. Data from BH and FB views were extracted to get respective SPECT images. An evaluation was first done for a phantom simulating the breathing lung, an elliptical acrylic shell where a balloon connected with an ambu bag was placed. Two point sources of 99m Tc (14 MBq) were attached on the balloon. The phantom study revealed BH method did not give any artifacts. Clinically, 201 Tl-SPECT images of patients with lung tumors were compared for resolution between BH and FB and for their accuracy of registration by superimposing on CT images. Such results were observed as that, when FB gave two regions of Tl accumulation, BH, one region agreeing with the one lesion in the CT image, and that, when Tl accumulation was visualized in BH, but not in FB due to its overlapping with the liver area. Thus BH method could reduce respiratory motion artifacts to improve resolution, and was thought applicable to other imaging methods. (R.T.)

  4. Quantitation of postexercise lung thallium-201 uptake during single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kahn, J.K.; Carry, M.M.; McGhie, I.; Pippin, J.J.; Akers, M.S.; Corbett, J.R.

    1989-01-01

    To test the hypothesis that analysis of lung thallium uptake measured during single photon emission computed tomography (SPECT) yields supplementary clinical information as reported for planar imaging, quantitative analysis of lung thallium uptake following maximal exercise was performed in 40 clinically normal subjects (Group 1) and 15 angiographically normal subjects (Group 2). Lung thallium uptake was measured from anterior projection images using a ratio of heart-to-lung activities. Seventy subjects with coronary artery disease (CAD) (Group 3) determined by angiography (greater than or equal to 70% luminal stenosis) underwent thallium perfusion SPECT. Thirty-nine percent of these subjects had multivessel and 61% had single vessel CAD. Lung thallium uptake was elevated in 47 of 70 (67%) Group 3 subjects. Group 3 subjects with elevated lung thallium uptake did not differ from Group 3 subjects with normal lung thallium uptake with respect to extent or distribution of coronary artery disease, left ventricular function, or severity of myocardial ischemia as determined by exercise and redistribution thallium SPECT. Thus, the measurement of thallium lung uptake from anterior projection images obtained during SPECT frequently identifies patients with CAD, but it may not provide supplementary information regarding the extent of myocardial ischemia or ventricular dysfunction

  5. Decreased Lung Perfusion After Breast/Chest Wall Irradiation: Quantitative Results From a Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Liss, Adam L., E-mail: adamliss68@gmail.com [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Marsh, Robin B. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kapadia, Nirav S. [Department of Radiation Oncology, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire (United States); McShan, Daniel L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Rogers, Virginia E. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Moran, Jean M.; Brock, Kristy K.; Schipper, Matt J.; Jagsi, Reshma [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Biostatistics Unit, University of Michigan, Ann Arbor, Michigan (United States); Flaherty, Kevin R. [Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Frey, Kirk A. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2017-02-01

    Purpose: To quantify lung perfusion changes after breast/chest wall radiation therapy (RT) using pre- and post-RT single photon emission computed tomography/computed tomography (SPECT/CT) attenuation-corrected perfusion scans; and correlate decreased perfusion with adjuvant RT dose for breast cancer in a prospective clinical trial. Methods and Materials: As part of an institutional review board–approved trial studying the impact of RT technique on lung function in node-positive breast cancer, patients received breast/chest wall and regional nodal irradiation including superior internal mammary node RT to 50 to 52.2 Gy with a boost to the tumor bed/mastectomy scar. All patients underwent quantitative SPECT/CT lung perfusion scanning before RT and 1 year after RT. The SPECT/CT scans were co-registered, and the ratio of decreased perfusion after RT relative to the pre-RT perfusion scan was calculated to allow for direct comparison of SPECT/CT perfusion changes with delivered RT dose. The average ratio of decreased perfusion was calculated in 10-Gy dose increments from 0 to 60 Gy. Results: Fifty patients had complete lung SPECT/CT perfusion data available. No patient developed symptoms consistent with pulmonary toxicity. Nearly all patients demonstrated decreased perfusion in the left lung according to voxel-based analyses. The average ratio of lung perfusion deficits increased for each 10-Gy increment in radiation dose to the lung, with the largest changes in regions of lung that received 50 to 60 Gy (ratio 0.72 [95% confidence interval 0.64-0.79], P<.001) compared with the 0- to 10-Gy region. For each increase in 10 Gy to the left lung, the lung perfusion ratio decreased by 0.06 (P<.001). Conclusions: In the assessment of 50 patients with node-positive breast cancer treated with RT in a prospective clinical trial, decreased lung perfusion by SPECT/CT was demonstrated. Our study allowed for quantification of lung perfusion defects in a prospective cohort of

  6. A new method for quantification of pulmonary thallium uptake in myocardial SPECT studies

    International Nuclear Information System (INIS)

    Mannting, F.

    1990-01-01

    Quantified pulmonary thallium 201 (Tl) uptake was assessed in 32 normal people and 66 patients with suspected coronary artery disease (CAD) by a new method utilizing SPECT acquisition data. In 26 subjects pulmonary uptake was assessed with both SPECT and planar techniques. Pulmonary/myocardial (PM) ratios for the whole right lung (PM1) and for the upper left lung (PM2) were computed and compared with stress test, coronary angiography, radionuclide angiography (ERNA), and quantified Tl SPECT results. Excellent correlation between pulmonary uptake assessed by planar and SPECT technique was disclosed (r=0.92). The PM ratio (PM1/PM2) sensitivity and specificity in patients with CAD was 88%/92% and 60%/70%, for predicting perfusion abnormalities 90%/87% and 88%/88%, and an inverse correlation to LVEF was found (r=-0.40/r=-0.37, P<0.01). Significant correlations to coronary angiography findings (r=0.54/r=0.49, P<0.001) and to number of vessel territories with abnormal perfusion (r=0.70/r=0.69, P<0.001) were seen. Thus, pulmonary Tl uptake can be assessed in SPECT studies. The new method's discriminative ability seems higher than that of the standard planar technique currently employed. Positive correlations to coronary angiography findings and even stronger ones to perfusion abnormalities were observed. (orig.)

  7. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    McQuaid, Sarah J; Hutton, Brian F

    2008-06-01

    Respiratory motion during myocardial perfusion imaging can cause artefacts in both positron emission tomography (PET) and single-photon emission computed tomography (SPECT) images when mismatches between emission and transmission datasets arise. In this study, artefacts from different breathing motions were quantified in both modalities to assess key factors in attenuation-correction accuracy. Activity maps were generated using the NURBS-based cardiac-torso phantom for different respiratory cycles, which were projected, attenuation-corrected and reconstructed to form PET and SPECT images. Attenuation-correction was performed with maps at mismatched respiratory phases to observe the effect on the left-ventricular myocardium. Myocardial non-uniformity was assessed in terms of the standard deviation in scores obtained from the 17-segment model and changes in uniformity were compared for each mismatch and modality. Certain types of mismatch led to artefacts and corresponding increases in the myocardial non-uniformity. For each mismatch in PET, the increases in non-uniformity relative to an artefact-free image were as follows: (a) cardiac translation mismatch, 84% +/- 11%; (b) liver mismatch, 59% +/- 10%, (c) lung mismatch from diaphragm contraction, 28% +/- 8%; and (d) lung mismatch from chest-wall motion, 6% +/- 7%. The corresponding factors for SPECT were (a) 61% +/- 8%, (b) 34% +/- 8%, (c) -2% +/- 7)% and (d) -4% +/- 6%. Attenuation-correction artefacts were seen in PET and SPECT images, with PET being more severely affected. The most severe artefacts were produced from mismatches in cardiac and liver position, whereas lung mismatches were less critical. Both cardiac and liver positions must, therefore, be correctly matched during attenuation correction.

  8. Value of {sup 99m}Tc-Technegas SPECT/CT for Localization of Alveolar-pleural Fistulas

    Energy Technology Data Exchange (ETDEWEB)

    Derlin, Thorsten [Hannover Medical School, Hannover (Germany); Salamon, Johannes; Laqmani, Azien [University Medical Center Hamburg-Eppendorf, Hamburg (Germany)

    2016-06-15

    A 77-year-old male with a history of recent resection of pulmonary metastasis from rectal cancer underwent ventilation single-photon emission computed tomography/computed tomography (SPECT/CT) for further evaluation of a persistent alveolar-pleural fistula resulting in pneumothorax and extensive soft tissue emphysema. It has been reported to be associated with incomplete interlobar fissures, emphysematous lungs, upper lobe resections and pleural adhesions. It frequently leads to a more complicated and protracted hospital course. In persistent air leaks, surgical re-exploration must be considered after failure of conservative treatment. Tc-Technegas ventilation scintigraphy is an established and well-studied tool for imaging of lung ventilation, and combined SPECT/CT has been shown to improve overall diagnostic accuracy in many areas of pulmonary nuclear medicine. Ventilation SPECT has been suggested to be useful for localization of air leaks before, but focal{sup 99m} Tc-Technegas deposition in the lung has not been evidenced to represent an actual fistula by either transport via the chest tube or surgical resection, for the previous reports relied on conservative treatment.

  9. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  10. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  11. Preserving Functional Lung Using Perfusion Imaging and Intensity-Modulated Radiation Therapy for Advanced-Stage Non-Small Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shioyama, Yoshiyuki; Jang, Si Young; Liu, H. Helen; Guerrero, Thomas; Wang, Xuanmin; Gayed, Isis W.; Erwin, William D.; Liao, Zhongxing; Chang, Joe Y.; Jeter, Melenda; Yaremko, Brian P.; Borghero, Yerko O.; Cox, James D.; Komaki, Ritsuko; Mohan, Radhe

    2007-01-01

    Purpose: To assess quantitatively the impact of incorporating functional lung imaging into intensity-modulated radiation therapy planning for locally advanced non-small cell lung cancer (NSCLC). Methods and Materials: Sixteen patients with advanced-stage NSCLC who underwent radiotherapy were included in this study. Before radiotherapy, each patient underwent lung perfusion imaging with single-photon-emission computed tomography and X-ray computed tomography (SPECT-CT). The SPECT-CT was registered with simulation CT and was used to segment the 50- and 90-percentile hyperperfusion lung (F50 lung and F90 lung). Two IMRT plans were designed and compared in each patient: an anatomic plan using simulation CT alone and a functional plan using SPECT-CT in addition to the simulation CT. Dosimetric parameters of the two types of plans were compared in terms of tumor coverage and avoidance of normal tissues. Results: In incorporating perfusion information in IMRT planning, the median reductions in the mean doses to the F50 and F90 lung in the functional plan were 2.2 and 4.2 Gy, respectively, compared with those in the anatomic plans. The median reductions in the percentage of volume irradiated with >5 Gy, >10 Gy, and >20 Gy in the functional plans were 7.1%, 6.0%, and 5.1%, respectively, for F50 lung, and 11.7%, 12.0%, and 6.8%, respectively, for F90 lung. A greater degree of sparing of the functional lung was achieved for patients with large perfusion defects compared with those with relatively uniform perfusion distribution. Conclusion: Function-guided IMRT planning appears to be effective in preserving functional lung in locally advanced-stage NSCLC patients

  12. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  13. Evaluation and reduction of respiratory motion artifacts in small animal SPECT with GATE

    International Nuclear Information System (INIS)

    Lee, C.-L.; Park, S.-J.; Kim, H.-J.

    2015-01-01

    The degradation of image quality caused by respiration is a major impediment to accurate lesion detection in single photon emission computed tomography (SPECT) imaging. This study was performed to evaluate the effects of lung motion on image quantification. A small animal SPECT system with NaI(Tl) was modeled in the Geant4 application for tomographic emission (GATE) simulation for a lung lesion using a 4D mouse whole-body phantom. SPECT images were obtained using 120 projection views acquired from 0 o to 360 o with a 3 o step. Slices were reconstructed using ordered subsets expectation maximization (OS-EM) without attenuation correction with five iterations and four subsets. Image quality was compared between the static mode without respiratory motion, and dynamic mode with respiratory motion in terms of spatial resolution was measured by the full width at half maximum (FWHM), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The FWHM of the non-gated image and the respiratory gated image were also compared. Spatial resolution improved as activity increased and lesion diameter decreased in the static and dynamic modes. The SNR and CNR increased significantly as lesion activity increased and lesion diameter decreased. Our results show that respiratory motion leads to reduced contrast and quantitative accuracy and that image quantification depends on both the amplitude and the pattern of the respiratory motion. We verified that respiratory motion can have a major effect on the accuracy of measurement of lung lesions and that respiratory gating can reduce activity smearing on SPECT images

  14. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  15. Complexity and accuracy of image registration methods in SPECT-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yin, L S; Duzenli, C; Moiseenko, V [Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1 (Canada); Tang, L; Hamarneh, G [Computing Science, Simon Fraser University, 9400 TASC1, Burnaby, BC, V5A 1S6 (Canada); Gill, B [Medical Physics, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Celler, A; Shcherbinin, S [Department of Radiology, University of British Columbia, 828 West 10th Ave, Vancouver, BC, V5Z 1L8 (Canada); Fua, T F; Thompson, A; Sheehan, F [Radiation Oncology, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Liu, M [Radiation Oncology, Fraser Valley Cancer Centre, BC Cancer Agency, 13750 9th Ave, Surrey, BC, V3V 1Z2 (Canada)], E-mail: lyin@bccancer.bc.ca

    2010-01-07

    The use of functional imaging in radiotherapy treatment (RT) planning requires accurate co-registration of functional imaging scans to CT scans. We evaluated six methods of image registration for use in SPECT-guided radiotherapy treatment planning. Methods varied in complexity from 3D affine transform based on control points to diffeomorphic demons and level set non-rigid registration. Ten lung cancer patients underwent perfusion SPECT-scans prior to their radiotherapy. CT images from a hybrid SPECT/CT scanner were registered to a planning CT, and then the same transformation was applied to the SPECT images. According to registration evaluation measures computed based on the intensity difference between the registered CT images or based on target registration error, non-rigid registrations provided a higher degree of accuracy than rigid methods. However, due to the irregularities in some of the obtained deformation fields, warping the SPECT using these fields may result in unacceptable changes to the SPECT intensity distribution that would preclude use in RT planning. Moreover, the differences between intensity histograms in the original and registered SPECT image sets were the largest for diffeomorphic demons and level set methods. In conclusion, the use of intensity-based validation measures alone is not sufficient for SPECT/CT registration for RTTP. It was also found that the proper evaluation of image registration requires the use of several accuracy metrics.

  16. Lung scintigraphy in the diagnosis of pulmonary embolism: current methods and interpretation criteria in clinical practice

    International Nuclear Information System (INIS)

    Skarlovnik, Ajda; Hrastnik, Damjana; Fettich, Jure; Grmek, Marko

    2014-01-01

    In current clinical practice lung scintigraphy is mainly used to exclude pulmonary embolism (PE). Modified diagnostic criteria for planar lung scintigraphy are considered, as newer scitigraphic methods, especially single photon emission computed tomography (SPECT) are becoming more popular. Data of 98 outpatients who underwent planar ventilation/perfusion (V/Q) scintigraphy and 49 outpatients who underwent V/Q SPECT from the emergency department (ED) were retrospectively collected. Planar V/Q images were interpreted according to 0.5 segment mismatch criteria and revised PIOPED II criteria and perfusion scans according to PISA-PED criteria. V/Q SPECT images were interpreted according to the criteria suggested in EANM guidelines. Final diagnosis of PE was based on the clinical decision of an attending physician and evaluation of a 12 months follow-up period. Using 0.5 segment mismatch criteria and revised PIOPED II, planar V/Q scans were diagnostic in 93% and 84% of cases, respectively. Among the diagnostic planar scans readings specificity for 0.5 segment mismatch criteria was 98%, and 99% for revised PIOPED II criteria. V/Q SPECT showed a sensitivity of 100% and a specificity of 98%, without any non-diagnostic cases. In patients with low pretest probability for PE, planar V/Q scans assessed by 0.5 segment mismatch criteria were diagnostic in 92%, and in 85% using revised PIOPED II criteria, while perfusion scintigraphy without ventilation scans was diagnostic in 80%. Lung scintigraphy yielded diagnostically definitive results and is reliable in ruling out PE in patients from ED. V/Q SPECT has excellent specificity and sensitivity without any non-diagnostic results. Percentage of non-diagnostic results in planar lung scintigraphy is considerably smaller when 0.5 segment mismatch criteria instead of revised PIOPED II criteria are used. Diagnostic value of perfusion scintigraphy according to PISA-PED criteria is inferior to combined V/Q scintigraphy; the difference is

  17. 99mTc-HL91 SPECT detects the relation between hypoxic changes and radiotherapy response of lung cancer

    International Nuclear Information System (INIS)

    Li Ling; Yu Jinming; Xing Ligang; Zhu Hui; Li Guoliang; Fang Yongcun

    2006-01-01

    Objective: To evaluate relation between hypoxia, hypoxic changes detected by 99m Tc-HL91 SPECT and the response to radiotherapy. Methods: Thirty-five patients with pathologically proven non-small cell lung cancer (NSCLC) treated by three-dimensional conformal radiotherapy were entered into the study. All patients were examined by examined by 99m Tc-HL9l SPECT imaging one or two days before radiotherapy. Twenty patients were monitored during radiotherapy(30-40 Gy) and one or two days after radiotherapy. Anterior', posterior and lateral planar images were collected 2 hours, 4 hours and 6 hours after intravenous injection approximately 740 MBq 99m Tc-HL91. Regions of interest(ROIs) were ch awn in the tumor and contralateral position and the radioactivity ratios of tumor to normal(T/N) were calculated. The response to radiotherapy was evaluated by solid tumor' s effect evaluation criterion (WHO) 3-6 months after radiotherapy. The correlations between T/N before radiotherapy, the T/N changes during radiotherapy and the response to radiotherapy were analyzed. Results: The T/N value gradually decreased before, during and after radiotherapy. The average T/N value before, during and after radiotherapy was 1.56±0.19, 1.40±0.12 and 1.29±0.13, respectively (F=10.13, P=0.010). The lower T/N ratio be- fore radiotherapy, the higher the response rate of radiotherapy (P=0.040). The larger change of T/N ratio before and after radiotherapy resulted in higher radiotherapy response, but with no statistical significance (P>0.05). Conclusions: The hypoxia status and hypoxic changes can be observed by HL91 SPECT imaging during radiotherapy which can predict the response to radiotherapy. (authors)

  18. The origins of SPECT and SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, Brian F. [University College London, Institute of Nuclear Medicine, London (United Kingdom); University of Wollongong, Centre for Medical Radiation Physics, Wollongong, NSW (Australia)

    2014-05-15

    Single photon emission computed tomography (SPECT) has a long history of development since its initial demonstration by Kuhl and Edwards in 1963. Although clinical utility has been dominated by the rotating gamma camera, there have been many technological innovations with the recent popularity of organ-specific dedicated SPECT systems. The combination of SPECT and CT evolved from early transmission techniques used for attenuation correction with the initial commercial systems predating the release of PET/CT. The development and acceptance of SPECT/CT has been relatively slow with continuing debate as to what cost/performance ratio is justified. Increasingly, fully diagnostic CT is combined with SPECT so as to facilitate optimal clinical utility. (orig.)

  19. Ventilation/perfusion SPECT/CT in patients with pulmonary emphysema. Evaluation of software-based analysing.

    Science.gov (United States)

    Schreiter, V; Steffen, I; Huebner, H; Bredow, J; Heimann, U; Kroencke, T J; Poellinger, A; Doellinger, F; Buchert, R; Hamm, B; Brenner, W; Schreiter, N F

    2015-01-01

    The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.

  20. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    Science.gov (United States)

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  1. Differential diagnosis in patients with ring-like thallium-201 uptake in brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kinuya, Keiko; Ohashi, Masahiro; Itoh, Syotaro [Tonami General Hospital, Toyama (Japan)] (and others)

    2002-09-01

    This study was performed to investigate lesions with ring-like thallium-201 ({sup 201}Tl) uptake and to determine whether SPECT provides any information in differential diagnosis. A total of 244 {sup 201}Tl SPECT images were reviewed. In each study, early (15 min postinjection) and late (3 hr) brain SPECT images were obtained with 111 MBq of {sup 201}Tl. The early uptake ratio (ER; lesion to normal brain average count ratio) and the late uptake ratio (LR) and the L/E ratio (ratio of LR to ER) were calculated. Ring-like uptake was observed in pre-therapeutic 26 SPECT images, including ten glioblastoma multiformes (ER, 3.45{+-}0.64; LR, 2.74{+-}0.54; L/E ratio 0.80{+-}0.13), five meningiomas (6.48{+-}2.34; 4.41{+-}1.41; 0.72{+-}0.19), four metastatic lung cancers (3.47{+-}1.23; 2.40{+-}0.98; 0.70{+-}0.14), four brain abscesses (2.48{+-}1.06; 1.59{+-}0.30; 0.78{+-}0.15), one invasive lesion of squamous cell carcinoma from the ethmoid sinus (1.54; 1.52; 0.99), one medulloblastoma (3.53; 3.52; 1.00) and one hematoma (3.32; 2.36; 0.71). The ER of meningioma was significantly higher than those of glioblastoma multiforme (p<0.0005), metastatic lung cancer (p<0.005) and brain abscess (p<0.0005). There were no significant differences among these three entities. The LR of meningioma was significantly higher than those of glioblastoma multiforme (p<0.005), metastatic lung cancer (p<0.005) and brain abscess (p<0.0001). The LR of brain abscess was significantly lower than that of glioblastoma multiforme (p<0.05). The L/E ratio could not differentiate these four entities. High ER and high LR in a lesion with ring-like uptake is likely an indicator of meningioma. The LR of brain abscess was significantly lower than that of glioblastoma multiforme, but {sup 201}Tl SPECT has still difficulty in differentiating abscess from brain tumor. (author)

  2. Vertebral uptake of Tc-99m macroaggregated albumin (MAA) with SPECT/CT occurring in superior vena cava obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma [Dept. of Nuclear Madicine, Royal Victoria Hospital, Montreal (Canada)

    2016-09-15

    A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.

  3. Functional avoidance of lung in plan optimization with an aperture-based inverse planning system

    International Nuclear Information System (INIS)

    St-Hilaire, Jason; Lavoie, Caroline; Dagnault, Anne; Beaulieu, Frederic; Morin, Francis; Beaulieu, Luc; Tremblay, Daniel

    2011-01-01

    Purpose: To implement SPECT-based optimization in an anatomy-based aperture inverse planning system for the functional avoidance of lung in thoracic irradiation. Material and methods: SPECT information has been introduced as a voxel-by-voxel modulation of lung importance factors proportionally to the local perfusion count. Fifteen cases of lung cancer have been retrospectively analyzed by generating angle-optimized non-coplanar plans, comparing a purely anatomical approach and our functional approach. Planning target volume coverage and lung sparing have been compared. Statistical significance was assessed by a Wilcoxon matched pairs test. Results: For similar target coverage, perfusion-weighted volume receiving 10 Gy was reduced by a median of 2.2% (p = 0.022) and mean perfusion-weighted lung dose, by a median of 0.9 Gy (p = 0.001). A separate analysis of patients with localized or non-uniform hypoperfusion could not show which would benefit more from SPECT-based treatment planning. Redirection of dose sometimes created overdosage regions in the target volume. Plans consisted of a similar number of segments and monitor units. Conclusions: Angle optimization and SPECT-based modulation of importance factors allowed for functional avoidance of the lung while preserving target coverage. The technique could be also applied to implement PET-based modulation inside the target volume, leading to a safer dose escalation.

  4. SPECT/CT and pulmonary embolism

    DEFF Research Database (Denmark)

    Mortensen, Jann; Borgwardt, Henrik Gutte

    2014-01-01

    the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume......Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar...

  5. Brain SPECT

    International Nuclear Information System (INIS)

    Feistel, H.

    1991-01-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG) [de

  6. Chilaiditi's syndrome demonstrated by SPECT/CT

    Directory of Open Access Journals (Sweden)

    Nalini S Perumal

    2009-11-01

    Full Text Available Purpose: Chilaiditi’s syndrome is a rare condition commonly diagnosed as an incidental radiological finding. The aim of this report is to show the role of SPECT-CT in this syndrome and state the functional and anatomical role of this hybrid imaging modality. Materials and Methods: A case report. Results: A 49-year-old female patient was referred for gallium-67 citrate for a possible granulomatous myositis and underwent SPECT-CT of the abdomen to assess the area of decreased gallium uptake on planar images of the liver. The combined SPECT and CT modality demonstrated findings consistent with the clinical evidence of Chilaiditi’s syndrome. The anatomical part of this hybrid modality made it easier to evaluate the area of gallium lack of uptake which was due to air in the colon. Conclusion: This case does not only show the role of SPECT-CT in this syndrome but also suggest that the use of such modality should be considered whenever available in the evaluation of patients in whom the localization of active disease becomes imperative.

  7. Fourier analysis of heart SPECT slices: from remodelation to function?

    International Nuclear Information System (INIS)

    Zigman, M.; Prpic, H.; Lokner, V.

    1994-01-01

    The aim of this study was to determine character of the spatial distribution of marked erythrocytes in heart chambers, lungs and great blood vessels in relation to function of the left and right heart. Investigation included total of 142 subjects, 28 of which were without subjective and clinical signs of heart disease as well as 56 after myocardial infarction (30 of anterior localization, 26 of inferior infarction), 35 with predominant left heart disease (aortic valve disease, dilatative myocardiopathy, etc.) and 23 with predominant right heart disease (atrial septal defect, mitral valve disease). Radionuclide ventriculography (RNV) at rest, and thorax SPECT were performed in all subjects with 740 MBq Tc-99m after in vivo erythrocyte labelling with pyrophosphate. Ultrasound investigation was performed on all the subjects with heart disease and 87 of them underwent invasive cardiac investigation. RNV analysis revealed scintigraphic data on left and right ventricle: global ejection fraction (GEF), end-systolic volume (ESV), end-diastolic volume (EDV), fast tilling rate (FFR), fast emptying rate (FER) as well as regional wall motion shortening. Reconstruction of 64x64x8 SPECT images resulted in 3x64 slices (transversal, coronal and sagittal slices). Fourier analysis of 20-32 reconstructed slices in all three dimensions gave amplitude image of the intensity distribution of marked erythrocytes in heart chambers lungs and great blood vessels as well as phase display of spatial localization of regional amplitude values. Results of joint ROC curves constructed for detection, localization and character of heart disease in all subjects revealed significant clinical information content of SPECT data. Evaluation of RI retention using amplitude images in 3D provides insight in regional changes of volume, particular for atrial and lung involvement. (author)

  8. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  9. Validation of co-registration of clinical lung ventilation and perfusion SPECT

    International Nuclear Information System (INIS)

    Marsh, S.H.; O'Keeffe, D.S.; Barnden, L.R.

    2010-01-01

    Full text: This talk will present results from a recent validation study of coregistration of computed tomography ventilation and perfusion (SPECT V/Q) images. The coregistration algorithm was incorporated in Qonsub, a program to coregister, normalise and subtract the SPECT (V/Q) images. Ventilation and perfusion image data were acquired from 23 patients undergoing a routine clinical SPECT V/Q study. The only change to normal patient management was the placement of three Tc 9 9 m filled fiducial markers adhered to the skin on the patient's torso. To quantify coregistration accuracy, image data were modified (within software) to remove the markers and Qonsub determined a parameter set of six values fully describing the six degree rigid transformation. The accuracy with which the six parameters coregister the images was then quantified by applying the same transformation parameters to the ventilation markers and determining how well they locate to the perfusion marker positions. Results show that for 65% of patients surveyed co-registration accuracy was to within I pixel, 30% were co-registered with an accuracy between 1 and 2 pixels and 5% were co-registered with an accuracy of between 2 and 3 pixels. Because patient placement between scans resulted in a misregistration of at most five pixels, a more rigorous test of the algorithm was required. Ethics approval had not been sought to intentionally misregister patient images, so the algorithm had to be further tested by synthetically misregistering the images. For these images Qonsub generally co-registered with the same accuracy as the original image. (author)

  10. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    2002-01-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  11. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    2002-03-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  12. SPECT/CT in gingival squamous cell carcinoma

    International Nuclear Information System (INIS)

    Nikolova, R.; Hadzhiyska, V.; Petrov, T.

    2015-01-01

    Gingival squamous cell carcinoma have a relatively poor prognosis and large differential diagnosis (periodontitis, osteomyelitis, etc.), therefore, it is usually diagnosed at a late stage. Hematogenous dissemination occurs in only about 10% of cases, including lung (66%), bone (22%), liver (10%), skin, bone marrow and mediastinum. Bone metastases are very rare compared to other malignancies, most commonly affect the axial skeleton (spine, pelvis, ribs and lumbar spine). In our case, we presented a patient with gingival squamous cell carcinoma and bone metastasis in the forearm detected with Whole Body Bone Scintigraphy (WBS), combined with Single Photon Emission Tomography /Computed Tomography (SPECT /CT). The obtained data suggest that the single use of WBS was not informative enough for making the final diagnosis, but the result of combined functional-morphological approach was the most pathognomonic. Thus, with single study can be obtained a complex information, which leads to a fast therapeutic decision. Key words: SPECT/CT. GINGiVAL. SQUAMOUS CELL CARCINOMA

  13. V/P SPECT as a diagnostic tool for pregnant women with suspected pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Bajc, Marika; Olsson, Berit; Joegi, Jonas [Skaane University Hospital and Lund University, Clinical Physiology and Nuclear Medicine, Lund (Sweden); Gottsaeter, Anders [Skaane University Hospital, Vascular Diseases, Malmoe (Sweden); Hindorf, Cecilia [Skaane University Hospital, Radiation Physics, Lund (Sweden)

    2015-07-15

    The purpose of the study was to assess the prevalence of pulmonary embolism (PE) and other lung diseases among pregnant women with suspected PE and to calculate the radiation exposure to patient and fetus in this population. As a secondary aim, we evaluated the negative predictive value of a normal ventilation/perfusion single photon emission computed tomography (V/P SPECT) examination in pregnancy. We studied all 127 pregnant women who had suspected PE and had undergone V/P SPECT at our institution in the course of a 5-year period. Radiation exposure to patient and fetus and the negative predictive value of a normal V/P SPECT examination were also measured. V/P SPECT identified PE in 11 women (9 %). Moreover, in 15 women (12 %) the examination revealed pneumonia (in 2 cases in addition to PE) and in 1 woman signs of airway obstruction were revealed. Among the 116/127 women (91 %) where PE was ruled out by V/P SPECT, none was diagnosed subsequently with PE or deep venous thrombosis (DVT) during the same pregnancy or puerperal period. For P SPECT, the calculated fetal absorbed dose was < 0.6 mGy,and the calculated breast absorbed dose 0.6 mGy. For V SPECT, the calculated fetal absorbed dose was < 0.014 mGy and the breast absorbed dose 0.25 mGy. The prevalence of PE was low (9 %) among pregnant women with suspected disease. Pneumonia was diagnosed in 12 % of patients. The negative predictive value of V/P SPECT was high, and the radiation exposure from V/P SPECT was low both for fetus and patient. (orig.)

  14. Brain SPECT in psychiatry: Delusion or reality?

    International Nuclear Information System (INIS)

    Pavel, D.G.; Davis, G.; Epstein, P.; Kohn, R.; Antonino, F.; Devore-Best, S.; Craita, I.; Liu, P.

    2002-01-01

    Aim: The need for functional information is becoming increasingly evident for proper therapeutic approaches to the treatment and follow up of psychiatric diseases. While data on this subject already exists, there is a general lack of consensus about the use of brain SPECT in this domain and also a considerable negative prejudice due to a number of factors including poor quality imaging and unrealistic expectations. Based on a large group of brain SPECT-s performed over the past 3 years we attempted to sort and refine the indications for SPECT in psychiatry. Materials and Methods: High resolution brain SPECT was performed with triple head gamma camera, super-high resolution fan beam collimator and Tc-HMPAO. A comprehensive semiquantitative color, 3D surface as well as multi-thresholded volume display was routinely used and supplemented by automatic realignment in case of longitudinal follow-up. Results: 470 brain SPECT-s done on 432 patients were all referred by psychiatrists or neuro-psychiatrists for a wide spectrum of psychiatric diseases and ranged in age from 7 to 88 years. The most common primary reasons for referral were : attention deficit hyperactive disorder (ADHD); anxiety; obsessive-compulsive disease, depression (refractory, chronic, bipolar ), impulse control problems; oppositional defiance, post traumatic brain injury; seizures, learning difficulties, pervasive development disorders, memory loss and differential of dementia. Among common denominators were long duration of the disease, unresponsiveness to treatment, worsening of clinical status, and presence of multiple conditions at the same time. The multiparametric display used enabled a comprehensive evaluation of the brain volume which included the hemispheric surfaces; the basal ganglia (striatum) and the thalamus, several components of the limbic and paralimbic systems: anterior and posterior cingulate and their respective subdivisions, insula-s and their subdivisions, apical and mesial

  15. A clinical comparison between Technegas SPECT, CT, and pulmonary function tests in patients with emphysema

    International Nuclear Information System (INIS)

    Satoh, Katashi; Nakano, Satoru; Tanabe, Masatada

    1997-01-01

    Pulmonary emphysema can be easily diagnosed by X-ray CT (CT) as low attenuation areas. Recently 99m Tc Technegas has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of SPECT images using Technegas scintigraphy and CT, as compared with pulmonary function tests in patients with pulmonary emphysema. Fifteen patients were examined. We classified and defined the score according to the findings of Technegas scintigraphy (Technegas) images into four grades, from Score 0 to Score 3, and those of CT into five grades, from Score 0 to Score 4, both from normal to severe. The right lung was divided into nine segments, and the left into eight. To obtain the average of the entire lung, the total score from both lungs was divided by 17. These average scores in for SPECT and CT were compared with the results of pulmonary function tests. The average score of Technegas correlated well with % forced expiratory volume in one second (%FEV 1.0 ) (r=0.87), and forced expiratory volume in one second % (FEV 1.0 %) (r=0.83). These results were better than those provided by CT. The average scores of the upper and lower lung fields were also calculated. The score in the upper lung field was higher than that in the lower field. Technegas can assess ventilation impairment in pulmonary emphysema more easily than CT, especially in the upper lung field. (author)

  16. Perfusion study in the pulmonary hilar region by SPECT

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Kawase, Yoshiro

    1990-01-01

    Alveoli in the hilar region comprise the peripheral area containing daughter branches from subsegmental or one more divisional peripheral bronchi. Pulmonary perfusion in hilar region was examined by SPECT (single photon emission CT) in ten normal volunteers. ROI (region of interest) in the axial images were set in the hilar region, the upper, middle and lower lung fields with 10.8 mm thickness. Counts/one pixel (C/P) were calculated in these ROI. There was a tendency of C/P increase from upper to lower lung field. And there were no significant differences in C/P increase between hilar region and other axial fields. In the chronic obstructive pulmonary diseases, however, ventilation studies in the previous reports using Xe dynamic CT or PET (positron emission tomography) showed differences between outer region and hilar region. This method will be expected to evaluate the pulmonary perfusion not only in the whole lung but in different lung areas, including the hilar region in the chronic obstructive pulmonary diseases. (author)

  17. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  18. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  19. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  20. Comparison of V/Q SPECT and planar V/Q lung scintigraphy in diagnosing acute pulmonary embolism

    DEFF Research Database (Denmark)

    Borgwardt, Henrik Gutte; Mortensen, Jann; Jensen, Claus Verner

    2010-01-01

    Planar ventilation/perfusion (V/Q) scintigraphy is currently the standard method for the diagnosis of pulmonary embolism (PE) in most nuclear medicine centers. However, recent studies have shown a superior sensitivity and specificity when applying V/Q single photon emission computed tomography...... (SPECT) in diagnosing PE. This study evaluated the diagnostic performance of three-dimensional V/Q SPECT in comparison with planar V/Q scintigraphy....

  1. Development of a Novel SPECT Tracer to Image c-Met Expression in Non-Small Cell Lung Cancer in a Human Tumor Xenograft.

    Science.gov (United States)

    Han, Zhaoguo; Xiao, Yadi; Wang, Kai; Yan, Ji; Xiao, Zunyu; Fang, Fang; Jin, Zhongnan; Liu, Yang; Sun, Xilin; Shen, Baozhong

    2018-05-18

    Rationale: Elevated expression of the c-Met receptor plays a crucial role in cancers. In non-small cell lung cancer (NSCLC), aberrant activation of c-Met signaling pathway contributes to tumorigenesis and cancer progression, and may mediate acquired resistance to epidermal growth factor receptor-targeted therapy. c-Met is therefore emerging as a promising therapeutic target for treating NSCLC, and the methods for noninvasive in vivo assessment of c-Met expression will improve NSCLC treatment and diagnosis. Methods: A new peptide-based (cMBP) radiotracer targeting c-Met, 99m Tc-hydrazine nicotinamide (HYNIC)-cMBP, was developed for single photon emission computed tomography (SPECT) imaging. Cell uptake assays were performed on two NSCLC cell lines with different c-Met expression: H1993 (high expression) and H1299 (no expression). In vivo tumor specificity was assessed by SPECT imaging in tumor-bearing mice at 0.5, 1, 2 and 4 h after injection of the probe. Blocking assays, biodistribution and autoradiography were also conducted to determine probe specificity. Results: 99m Tc-HYNIC-cMBP was prepared with high efficiency and showed higher uptake in H1993 cells than H1299 cells. Biodistribution and autoradiography also showed significantly higher accumulation of 99m Tc-HYNIC-cMBP in H1993 tumors than H1299 (H1993: 4.74±1.43 %ID/g and H1299: 1.00±0.37 %ID/g at 0.5h, pc-Met was demonstrated by competitive block with excess un-radiolabeled peptide. Conclusion: We developed a novel SPECT tracer, 99m Tc-HYNIC-cMBP, for c-Met-targeted imaging in NSCLC that specifically bound to c-Met with favorable pharmacokinetics in vitro and in vivo. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  2. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  3. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  4. Noninvasive imaging of experimental lung fibrosis.

    Science.gov (United States)

    Zhou, Yong; Chen, Huaping; Ambalavanan, Namasivayam; Liu, Gang; Antony, Veena B; Ding, Qiang; Nath, Hrudaya; Eary, Janet F; Thannickal, Victor J

    2015-07-01

    Small animal models of lung fibrosis are essential for unraveling the molecular mechanisms underlying human fibrotic lung diseases; additionally, they are useful for preclinical testing of candidate antifibrotic agents. The current end-point measures of experimental lung fibrosis involve labor-intensive histological and biochemical analyses. These measures fail to account for dynamic changes in the disease process in individual animals and are limited by the need for large numbers of animals for longitudinal studies. The emergence of noninvasive imaging technologies provides exciting opportunities to image lung fibrosis in live animals as often as needed and to longitudinally track the efficacy of novel antifibrotic compounds. Data obtained by noninvasive imaging provide complementary information to histological and biochemical measurements. In addition, the use of noninvasive imaging in animal studies reduces animal usage, thus satisfying animal welfare concerns. In this article, we review these new imaging modalities with the potential for evaluation of lung fibrosis in small animal models. Such techniques include micro-computed tomography (micro-CT), magnetic resonance imaging, positron emission tomography (PET), single photon emission computed tomography (SPECT), and multimodal imaging systems including PET/CT and SPECT/CT. It is anticipated that noninvasive imaging will be increasingly used in animal models of fibrosis to gain insights into disease pathogenesis and as preclinical tools to assess drug efficacy.

  5. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    Science.gov (United States)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between

  6. Radiation-Induced Reductions in Regional Lung Perfusion: 0.1-12 Year Data From a Prospective Clinical Study

    International Nuclear Information System (INIS)

    Zhang Junan; Ma Jinli; Zhou Sumin; Hubbs, Jessica L.; Wong, Terence Z.; Folz, Rodney J.; Evans, Elizabeth S.; Jaszczak, Ronald J.; Clough, Robert; Marks, Lawrence B.

    2010-01-01

    Purpose: To assess the time and regional dependence of radiation therapy (RT)-induced reductions in regional lung perfusion 0.1-12 years post-RT, as measured by single photon emission computed tomography (SPECT) lung perfusion. Materials/Methods: Between 1991 and 2005, 123 evaluable patients receiving RT for tumors in/around the thorax underwent SPECT lung perfusion scans before and serially post-RT (0.1-12 years). Registration of pre- and post-RT SPECT images with the treatment planning computed tomography, and hence the three-dimensional RT dose distribution, allowed changes in regional SPECT-defined perfusion to be related to regional RT dose. Post-RT follow-up scans were evaluated at multiple time points to determine the time course of RT-induced regional perfusion changes. Population dose response curves (DRC) for all patients at different time points, different regions, and subvolumes (e.g., whole lungs, cranial/caudal, ipsilateral/contralateral) were generated by combining data from multiple patients at similar follow-up times. Each DRC was fit to a linear model, and differences statistically analyzed. Results: In the overall groups, dose-dependent reductions in perfusion were seen at each time post-RT. The slope of the DRC increased over time up to 18 months post-RT, and plateaued thereafter. Regional differences in DRCs were only observed between the ipsilateral and contralateral lungs, and appeared due to tumor-associated changes in regional perfusion. Conclusions: Thoracic RT causes dose-dependent reductions in regional lung perfusion that progress up to ∼18 months post-RT and persists thereafter. Tumor shrinkage appears to confound the observed dose-response relations. There appears to be similar dose response for healthy parts of the lungs at different locations.

  7. Assessment of early radiation effects on the liver. Comparison of SPECT and MR

    International Nuclear Information System (INIS)

    Masui, T.

    1996-01-01

    Purpose: To evaluate the early effects of radiation on the liver using single photon emission CT (SPECT) with 99m Tc-phytate combined with a pinhole collimator and MR imaging with superparamagnetic iron oxide (SPIO) and to compare 2 modalities regarding the assessment of the reticuloendothelial cell function. Material and Methods: The right sides of the livers of 12 anesthetized rats were irradiated with X-rays (4000 Cgy). On the 3rd and 4th days postirradiation, SPECT and MR imaging pre- and postcontrast were performed. Results: On SPECT, the irradiated areas appeared as areas with reduced 99m Tc-phytate uptake in 9 rats. In the remaining 3 rats, irradiated lesions were not evident on SPECT. On the early postcontrast MR images, differential negative enhancement of the irradiated and nonirradiated areas in the same 9 rats as on SPECT was apparent. However, on the later postcontrast images of 3 of these rats, the irradiated areas, which were brighter than the nonirradiated areas, were visually less clear than those on the earlier postcontrast images. In the remaining 3 rats, no radiation damag was evident on MR images. Conclusion: SPECT with 99m Tc-phytate and early postcontrast MR imaging with SPIO can show early radiation damage of the liver. The serial assessment of the postcontrast MR images provides functional information on the Kupffer cells. (orig.)

  8. Comparison of ventilation-perfusion single-photon emission computed tomography (V/Q SPECT) versus dual-energy CT perfusion and angiography (DECT) after 6 months of pulmonary embolism (PE) treatment

    Energy Technology Data Exchange (ETDEWEB)

    Meysman, M., E-mail: marc.meysman@uzbrussel.be [Respiratory Division, Department of Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Everaert, H., E-mail: nucgeth@gmail.com [Department of Nuclear Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Buls, N., E-mail: nico.buls@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Nieboer, K., E-mail: koenraad.nieboer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium); Mey, J. de, E-mail: Johan.deMey@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels (Belgium)

    2015-09-15

    Highlights: • Incomplete resolution of pulmonary emboli occurs frequently. • Residual V/Q-SPECT defects correspond in the majority of cases with defects seen on DECT. • Some (11.1%) defects on V/Q-SPECT are not present on comparable DECT images. - Abstract: Background: The natural evolution of treated symptomatic pulmonary embolism shows often incomplete resolution of pulmonary thrombi. The prevalence of perfusion defects depend on the image modality used. This study directly compares V/Q SPECT with DECT. Methods: A single-center prospective observational cohort study of patients with intermediate risk PE, reassessed at the end of treatment with V/Q SPECT. Abnormal V/Q SPECT images were compared with DECT. Results: We compared DECT en V/Q SPECT in 28 consecutive patients with persistent V/Q mismatch on V/Q SPECT, 13 men and 15 woman, mean age 60 (+17), range 23–82 year. One patient was excluded from the final analysis due to inferior quality DECT. In 18/27 (66.7%) the results were concordant between CTPA (persistent embolus visible), DECT (segmentary defects on iodine map) and V/Q SPECT (segmentary ventilation–perfusion mismatch). In 3/18 (11.1% of the total group) the partialy matched V/Q SPECT defect could be explained on DECT lung images by lung infarction. In 6/27 (22.1%) only hypoperfusion was seen on DECT iodine map. In 3/27 (11.1%) results were discordant between V/Q SPECT and DECT images. Conclusion: Six months after diagnosis of first or recurrent PE, residual pulmonary perfusion-defects encountered on V/Q-SPECT corresponds in the majority of patients with chronic thromboembolic disease seen on DECT. In 22.1% of patients V/Q SPECT mismatch only corresponds with hypoperfusion on iodine map DECT scan. Some (11.1%) of the chronic thromboembolic lesions seen on V/Q SPECT can not be explained by DECT results.

  9. Single-photon emission computed tomography/computed tomography in lung cancer and malignant lymphoma.

    Science.gov (United States)

    Schillaci, Orazio

    2006-10-01

    In nuclear oncology, despite the fast-growing diffusion of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET), single-photon emission computed tomography (SPECT) studies can still play an useful clinical role in several applications. The main limitation of SPECT imaging with tumor-seeking agents is the lack of the structural delineation of the pathologic processes they detect; this drawback sometimes renders SPECT interpretation difficult and can diminish its diagnostic accuracy. Fusion with morphological studies can overcome this limitation by giving an anatomical map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT images proved to be time-consuming and impractical for routine use. The recent development of dual-modality integrated imaging systems that provide functional (SPECT) and anatomical (CT) images in the same scanning session, with the acquired images coregistered by means of the hardware, has opened a new era in this field. The first reports indicate that SPECT/CT is very useful in cancer imaging because it is able to provide further information of clinical value in several cases. In SPECT, studies of lung cancer and malignant lymphomas using different radiopharmaceutical, hybrid images are of value in providing the correct localization of tumor sites, with a precise detection of the involved organs, and the definition of their functional status, and in allowing the exclusion of disease in sites of physiologic tracer uptake. Therefore, in lung cancer and lymphomas, hybrid SPECT/CT can play a role in the diagnosis of the primary tumor, in the staging of the disease, in the follow-up, in the monitoring of therapy, in the detection of recurrence, and in dosimetric estimations for target radionuclide therapy.

  10. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  11. COMPLEX CLINICAL AND INSTRUMENTAL EVALUATION OF LUNG INJURY IN PATIENTS WITH RHEUMATOID ARTHRITIS

    Directory of Open Access Journals (Sweden)

    I. I. Nesterovich

    2016-01-01

    Full Text Available The damage of the respiratory system is a quite common  extra-articular manifestation  of rheumatoid  arthritis (RA. It is important  to note that its clinical symptoms occur in only 20–30% of patients; however, subclinical forms identified by active screening are observed in 70–80% of patients.Objective: to compare the significance of pulmonary complaints,  the results of physical examination, and the data of instrumental  studies for the detection  of lung injury in patients with RA.Subjects and methods. The study enrolled 70 RA patients (63 women and 7 men aged 24 to 83 years. Only 10% of them had clinically evident lung injury associated with RA. Patients with other pulmonary diseases, such as asthma, chronic obstructive pulmonary disease, etc., were excluded. Physical examination, radiography/fluoroscopy, high-resolution computed  tomography (HRCT, single-photon emission computed  tomography (SPECT of the lung, and lung function testing (LFT with the determination of lung diffusion capacity.Results and discussion. The data of physical examination  were nonspecific and unconvincing.  Pulmonary  complaints (dyspnea, cough, expectoration were seen in 65% of the patients; an objective assessment revealed changes (vesiculotympanitic resonance,  harsh breathing, and pleural friction rub in 40%. The X-ray films/fluorograms  displayed abnormalities (pulmonary fibrosis, focal changes in only 10% of cases. 92% of the patients had lung HRCT  changes including moderate (bronchial  obstruction (40%, rheumatoid  nodules (10%, ground glass opacities (60%, bronchial thickening (20%, pleural effusion (10%, tree-in-bud opacities (3% and severe (pulmonary hypertension  (10%, bronchiectasis (10%, emphysema (5% and lung tissue fibrotic changes as the honeycomb lung (2% ones. SPECT showed local hypoperfusion in the mantle and mediastinal parts of the lungs in 80% of cases. LFT analysis demonstrated reduced lung diffusion capacity in 41% of

  12. Lipidomic Profiling of Lung Pleural Effusion Identifies Unique Metabotype for EGFR Mutants in Non-Small Cell Lung Cancer

    OpenAIRE

    Ying Swan Ho; Lian Yee Yip; Nurhidayah Basri; Vivian Su Hui Chong; Chin Chye Teo; Eddy Tan; Kah Ling Lim; Gek San Tan; Xulei Yang; Si Yong Yeo; Mariko Si Yue Koh; Anantham Devanand; Angela Takano; Eng Huat Tan; Daniel Shao Weng Tan

    2016-01-01

    Cytology and histology forms the cornerstone for the diagnosis of non-small cell lung cancer (NSCLC) but obtaining sufficient tumour cells or tissue biopsies for these tests remains a challenge. We investigate the lipidome of lung pleural effusion (PE) for unique metabolic signatures to discriminate benign versus malignant PE and EGFR versus non-EGFR malignant subgroups to identify novel diagnostic markers that is independent of tumour cell availability. Using liquid chromatography mass spect...

  13. Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results.

    Science.gov (United States)

    Goshen, Elinor; Beilin, Leonid; Stern, Eli; Kenig, Tal; Goldkorn, Ronen; Ben-Haim, Simona

    2018-03-14

    The performance of a prototype novel digital single-photon emission computed tomography (SPECT) camera with multiple pixelated CZT detectors and high sensitivity collimators (Digital SPECT; Valiance X12 prototype, Molecular Dynamics) was evaluated in various clinical settings. Images obtained in the prototype system were compared to images from an analog camera fitted with high-resolution collimators. Clinical feasibility, image quality, and diagnostic performance of the prototype were evaluated in 36 SPECT studies in 35 patients including bone (n = 21), brain (n = 5), lung perfusion (n = 3), and parathyroid (n = 3) and one study each of sentinel node and labeled white blood cells. Images were graded on a scale of 1-4 for sharpness, contrast, overall quality, and diagnostic confidence. Digital CZT SPECT provided a statistically significant improvement in sharpness and contrast in clinical cases (mean score of 3.79 ± 0.61 vs. 3.26 ± 0.50 and 3.92 ± 0.29 vs. 3.34 ± 0.47 respectively, p < 0.001 for both). Overall image quality was slightly higher for the digital SPECT but not statistically significant (3.74 vs. 3.66). CZT SPECT provided significantly improved image sharpness and contrast compared to the analog system in the clinical settings evaluated. Further studies will evaluate the diagnostic performance of the system in large patient cohorts in additional clinical settings.

  14. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections.

    Science.gov (United States)

    Monteiro, Paulo Henrique Silva; de Souza, Thiago Ferreira; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Mengatti, Jair; de Lima, Mariana da Cunha Lopes; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  15. Differential diagnosis in patients with ring-like thallium-201 uptake in brain SPECT

    International Nuclear Information System (INIS)

    Kinuya, Keiko; Ohashi, Masahiro; Itoh, Syotaro

    2002-01-01

    This study was performed to investigate lesions with ring-like thallium-201 ( 201 Tl) uptake and to determine whether SPECT provides any information in differential diagnosis. A total of 244 201 Tl SPECT images were reviewed. In each study, early (15 min postinjection) and late (3 hr) brain SPECT images were obtained with 111 MBq of 201 Tl. The early uptake ratio (ER; lesion to normal brain average count ratio) and the late uptake ratio (LR) and the L/E ratio (ratio of LR to ER) were calculated. Ring-like uptake was observed in pre-therapeutic 26 SPECT images, including ten glioblastoma multiformes (ER, 3.45±0.64; LR, 2.74±0.54; L/E ratio 0.80±0.13), five meningiomas (6.48±2.34; 4.41±1.41; 0.72±0.19), four metastatic lung cancers (3.47±1.23; 2.40±0.98; 0.70±0.14), four brain abscesses (2.48±1.06; 1.59±0.30; 0.78±0.15), one invasive lesion of squamous cell carcinoma from the ethmoid sinus (1.54; 1.52; 0.99), one medulloblastoma (3.53; 3.52; 1.00) and one hematoma (3.32; 2.36; 0.71). The ER of meningioma was significantly higher than those of glioblastoma multiforme (p 201 Tl SPECT has still difficulty in differentiating abscess from brain tumor. (author)

  16. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  17. Weight of evidence analysis of lung cancer in Colorado Plateau uranium miners

    International Nuclear Information System (INIS)

    Groeer, P.G.; Wallace, P.W.; Pereira, A. de B.

    1989-01-01

    The authors use a Bayesian contingency table analysis to assess lung cancer in the Colorado plateau uranium miners. This population is studied by Whittemore, Hornung and BEIR-IV, but none of these includes the radiation dose from hard rock mining that about 38% of the miners have accumulated. The analysis uses 'weight of evidence' which Good applied to the analysis of lung cancer many years ago. The analysis indicates that only in those exposed for a long period and at high exposure rates is the weight of evidence positive with a coefficient of variation less than unity that radiation is associated with the lung cancers. The coefficient of variation is a criterion of the significance of the weight of evidence for the association of the radon exposure in the miners with lung cancer. In the subsequent discussion it is suggested that this approach is similar to the probability of causation, which it is not. (author)

  18. Ventilation abnormalities in obstructive airways disorder. Detection with pulmonary dynamic densitometry by means of spinal CT versus dynamic Xe-133 SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Nishigauchi, Kazuya; Kume, Norihiko; Takana, Katsuyuki; Koike, Shinji; Shimizu, Kensaku; Matsunaga, Naofumi

    1999-01-01

    The usefulness of pulmonary dynamic densitometry (PDD) acquired by spiral computed tomography (CT) to detect ventilation abnormalities in obstructive airway disorders was evaluated in comparison with dynamic xenon-133 (Xe-133) SPECT. Eight-second, continuous spiral CT scan was performed over 2-3 respiratory cycles in six healthy volunteers, 19 patients with airways disorder, and six patients with restrictive lung disease. The data set were reconstructed as 36 one-second temporally overlapping images at 0.2-second intervals, and regional PDD curves were displayed. Regional ventilation was assessed by Xe-133 clearance-time on Xe-133 SPECT. Normal lungs showed smooth, sinusoidal PDD curves with maximal amplitude in lung attenuation change (MALAC) of 54.9+24.5 HU; whereas, obstructive airways disorders with prolonged Xe-133 clearance showed significantly diminished MALAC (31.6+20.1 HU, P<0.0001), accompanied by irregularity, asynchronous phase, and deterioration of normal ventral-to-dorsal gradients in MALAC and lung attenuation. Restrictive diseases without prolonged Xe-133 clearance did not show statistically significant reduction in MALAC. In total 251 lung regions, regional MALAC correlated inversely with Xe-133 clearance-time (r=842). PDD acquired by spiral CT is acceptable for detecting ventilation abnormalities in obstructive airways disorder. (author)

  19. A subtraction and 3D display program for the assessment of pulmonary embolism in SPECT V/Q scans

    International Nuclear Information System (INIS)

    Barnden, Leighton; Badger, Daniel P.

    2009-01-01

    Full text: There is interest in whether SPECT can improve the detection of pulmonary emboli with ventilation/perfusion (V /Q) scanning compared to the conventional multi-view planar imaging approach. We have extended V/Q SPECT processing to include coregistration, normalization and subtraction of the two scans. The unpredictable deposition of technegas activity in bronchi can introduce significant differences between otherwise normal V and Q scans and poses a challenge to both the coregistration and normalization needed before performing subtraction. QONSUB, a graphical-user-interface driven program originally written to assess epilepsy with brain SPECT (Badger and Barnden. Proc ANZSNM, 2008) has been adapted for assessment of V/Q lung SPECT. It includes rigid (+zoom) coregistration of the whole images or automatically determined sub images that contain the entire lungs. Count normalization was performed with either the mean or median counts. Extreme hot spots in ventilation images were observed to adversely affect the co-registration. We show that truncation to an upper threshold before co-registration corrects this. Similarly, normalization using a mean was seriously affected by such ventilation hotspots. This was circumvented by using the median instead. The program offers display of the ventilation, perfusion and difference images in 3 linked panels with mouse-driven roam through their transaxial, sagittal and coronal sections, and mouse-driven scaling. Dragging the cursor horizontally across a sagittal image causes the corresponding coronal sections to change in all 4 panels, and so on. The multi-panel 3D display was well accepted by physicians and the program's clinical usefulness is under evaluation.

  20. Quantification of neutrophil migration into the lungs of patients with chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Ruparelia, Prina; Summers, Charlotte; Chilvers, Edwin R [University of Cambridge School of Clinical Medicine, Department of Respiratory Medicine, Cambridge (United Kingdom); Szczepura, Katherine R [University of Cambridge School of Clinical Medicine, Department of Radiology, Cambridge (United Kingdom); Solanki, Chandra K; Balan, Kottekkattu [Cambridge University Hospitals NHS Foundation Trust, Nuclear Medicine, Addenbrooke' s Hospital, Cambridge (United Kingdom); Newbold, Paul [AstraZeneca R and D Charnwood, Loughborough (United Kingdom); Bilton, Diana [Papworth Hospital NHS Foundation Trust, Cystic Fibrosis and Lung Defence Unit, Papworth Everard (United Kingdom); Peters, A M [University of Cambridge School of Clinical Medicine, Department of Radiology, Cambridge (United Kingdom); Brighton Sussex Medical School, Brighton (United Kingdom)

    2011-05-15

    To quantify neutrophil migration into the lungs of patients with chronic pulmonary obstructive disease (COPD). Neutrophil loss via airways was assessed by dedicated whole-body counting 45 min, 24 h and 2, 4, 7 and 10 days after injection of very small activities of {sup 111}In-labelled neutrophils in 12 healthy nonsmokers, 5 healthy smokers, 16 patients with COPD (of whom 7 were ex-smokers) and 10 patients with bronchiectasis. Lung accumulation of {sup 99m}Tc-labelled neutrophils was assessed by sequential SPECT and Patlak analysis in six COPD patients and three healthy nonsmoking subjects. Whole body {sup 111}In counts, expressed as percentages of 24 h counts, decreased in all subjects. Losses at 7 days (mean {+-} SD) were similar in healthy nonsmoking subjects (5.5 {+-} 1.5%), smoking subjects (6.5 {+-} 4.4%) and ex-smoking COPD patients (5.8 {+-} 1.5%). In contrast, currently smoking COPD patients showed higher losses (8.0 {+-} 3.0%) than healthy nonsmokers (p = 0.03). Two bronchiectatic patients lost 25% and 26%, indicating active disease; mean loss in the remaining eight was 6.9 {+-} 2.5%. The rate of accumulation of {sup 99m}Tc-neutrophils in the lungs, determined by sequential SPECT, was increased in COPD patients (0.030-0.073 min{sup -1}) compared with healthy nonsmokers (0-0.002 min{sup -1}; p = 0.02). In patients with COPD, sequential SPECT showed increased lung accumulation of {sup 99m}Tc-labelled neutrophils, while whole-body counting demonstrated subsequent higher losses of {sup 111}In-labelled neutrophils in patients who continued to smoke. Sequential SPECT as a means of quantifying neutrophil migration deserves further evaluation. (orig.)

  1. Quantification of neutrophil migration into the lungs of patients with chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Ruparelia, Prina; Summers, Charlotte; Chilvers, Edwin R.; Szczepura, Katherine R.; Solanki, Chandra K.; Balan, Kottekkattu; Newbold, Paul; Bilton, Diana; Peters, A.M.

    2011-01-01

    To quantify neutrophil migration into the lungs of patients with chronic pulmonary obstructive disease (COPD). Neutrophil loss via airways was assessed by dedicated whole-body counting 45 min, 24 h and 2, 4, 7 and 10 days after injection of very small activities of 111 In-labelled neutrophils in 12 healthy nonsmokers, 5 healthy smokers, 16 patients with COPD (of whom 7 were ex-smokers) and 10 patients with bronchiectasis. Lung accumulation of 99m Tc-labelled neutrophils was assessed by sequential SPECT and Patlak analysis in six COPD patients and three healthy nonsmoking subjects. Whole body 111 In counts, expressed as percentages of 24 h counts, decreased in all subjects. Losses at 7 days (mean ± SD) were similar in healthy nonsmoking subjects (5.5 ± 1.5%), smoking subjects (6.5 ± 4.4%) and ex-smoking COPD patients (5.8 ± 1.5%). In contrast, currently smoking COPD patients showed higher losses (8.0 ± 3.0%) than healthy nonsmokers (p = 0.03). Two bronchiectatic patients lost 25% and 26%, indicating active disease; mean loss in the remaining eight was 6.9 ± 2.5%. The rate of accumulation of 99m Tc-neutrophils in the lungs, determined by sequential SPECT, was increased in COPD patients (0.030-0.073 min -1 ) compared with healthy nonsmokers (0-0.002 min -1 ; p = 0.02). In patients with COPD, sequential SPECT showed increased lung accumulation of 99m Tc-labelled neutrophils, while whole-body counting demonstrated subsequent higher losses of 111 In-labelled neutrophils in patients who continued to smoke. Sequential SPECT as a means of quantifying neutrophil migration deserves further evaluation. (orig.)

  2. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    International Nuclear Information System (INIS)

    Monteiro, Paulo Henrique Silva; Souza, Thiago Ferreira de; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Lima, Mariana da Cunha Lopes de; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. Materials And Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. (author)

  3. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Silva Monteiro

    2017-10-01

    Full Text Available Abstract Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs in systemic granulomatous infections in comparison with gallium-67 (67Ga citrate scintigraphy. Materials and Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99mTc-EDDA-HYNIC-TOC, and 21 after injection of 111In-DTPA-octreotide. All patients also underwent 67Ga citrate imaging, except for one patient who died before the 67Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67Ga uptake in 11 of the 20 patients with positive images and similar to 67Ga uptake in the other 9 patients. The only patient who did not undergo 67Ga scintigraphy underwent 99mTc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with 99mTc-EDDA-HYNIC-TOC or 111In-DTPA-octreotide seems to be a good alternative to 67Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  4. Comparison of 133Xe gas dynamic SPECT and thin-section CT in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    2001-01-01

    We assessed 133 Xe gas dynamic single photon emission computed tomography (SPECT) by comparing washout axial images with thin-section CT (TSCT) in patients with pulmonary emphysema. Twenty-three patients were studied. All patients were diagnosed as having pulmonary emphysema on the basis of TSCT. We compared TSCT of upper, middle and lower lung fields with 133 Xe gas dynamic SPECT axial images at the corresponding levels during the 3 to 4 minutes of washout phase. If the degree of 133 Xe gas retention or TSCT finding of ventral and dorsal parts was not the same, the images were divided into two parts. A total of 174 lesions in 23 cases were examined, but 3 lesions having no retention of 133 Xe gas at equilibrium phase were excluded. The results showed that: there were 37 lesions (21.6%) with equivalent severity on both images; there were 42 lesions (24.5%) with more severity on 133 Xe gas dynamic SPECT than on TSCT; and there were 92 lesions (53.8%) with more severity on TSCT than on 133 Xe gas dynamic SPECT. The severity on 133 Xe gas dynamic SPECT and TSCT was not always compatible. One of the reasons for the variable 133 Xe gas retention even when the lesion had the same severity on TSCT, may be bronchial stricture which cannot be seen on TSCT. By comparison of axial images of 133 Xe gas dynamic SPECT with CT images, we could recognize the areas of 133 Xe gas retention in detail. Results suggest that 133 Xe gas dynamic SPECT can be useful to identify ventilation impairment in pulmonary emphysema. (author)

  5. Serial SPECT in children with partial epilepsy

    International Nuclear Information System (INIS)

    Hosoya, Machiko; Ushiku, Hideo

    1995-01-01

    We performed serial single-photon emission CT (SPECT) with N-isopropyl-p-( 123 I)-Iodoamphetamine to measure the regional cerebral blood flow (rCBF) in 15 children with partial epilepsy. SPECT showed focal changes in 14 cases. Ten cases had abnormalities in the initial SPECT and another four cases in the second test. The cases with normal rCBF in initial SPECT had been tested in an early phase after the onset, and then decreased rCBF were observed in the second SPECT. The cases with both abnormal rCBF in the initial SPECT and improved rCBF in the second SPECT showed good prognosis in clinico-electrophysiological evolutions. In cases with abnormal changes of rCBF in the second SPECT, clinical prognosis was found to be not so good. These findings suggest that serial SPECT may be used to follow the course of epilepsy. (author)

  6. Quantitative study of 99mTc-Technegas SPECT for ventilatory impairment in pulmonary emphysema. Regional distribution. Correlation of SPECT with pulmonary function test

    International Nuclear Information System (INIS)

    Satoh, Katashi; Mitani, Masahiro; Yamamoto, Yuka; Nishiyama, Yoshihiro; Ohkawa, Motoomi

    2003-01-01

    99m Tc-Technegas scintigraphy is used for evaluation of abnormality of ventilation in pulmonary emphysema. Although the abnormality of ventilation distribution is very easy to find, there is not an objective index. The evaluation is subjective and different by each radiologist. It was also difficult to compare each cases and the clinical course in the same case. The present study for quantitative evaluation has proved that excellent correlations is obtained between the mean voxel values of the lung and stage classification. Furthermore, a correlation is observed between the mean and forced expiratory volume in 1 second (FEV 1.0 )%. These data indicate that quantitative analysis of SPECT seem to be useful to classify the clinical stage and compare the each cases. And respiratory function decreases as much as chronic pulmonary emphysema exists in the lower lung field. (author)

  7. Framework for radiation pneumonitis risk stratification based on anatomic and perfused lung dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Dhami, Gurleen; Zeng, Jing; Patel, Shilpen A.; Rengan, Ramesh [University of Washington School of Medicine, Department of Radiation Oncology, Seattle, WA (United States); Vesselle, Hubert J.; Kinahan, Paul E.; Miyaoka, Robert S. [University of Washington School of Medicine, Department of Radiology, Seattle, WA (United States); Bowen, Stephen R. [University of Washington School of Medicine, Department of Radiation Oncology, Seattle, WA (United States); University of Washington School of Medicine, Department of Radiology, Seattle, WA (United States)

    2017-05-15

    To design and apply a framework for predicting symptomatic radiation pneumonitis in patients undergoing thoracic radiation, using both pretreatment anatomic and perfused lung dose-volume parameters. Radiation treatment planning CT scans were coregistered with pretreatment [{sup 99m}Tc]MAA perfusion SPECT/CT scans of 20 patients who underwent definitive thoracic radiation. Clinical radiation pneumonitis was defined as grade ≥ 2 (CTCAE v4 grading system). Anatomic lung dose-volume parameters were collected from the treatment planning scans. Perfusion dose-volume parameters were calculated from pretreatment SPECT/CT scans. Equivalent doses in 2 Gy per fraction were calculated in the lung to account for differences in treatment regimens and spatial variations in lung dose (EQD2{sub lung}). Anatomic lung dosimetric parameters (MLD) and functional lung dosimetric parameters (pMLD{sub 70%}) were identified as candidate predictors of grade ≥ 2 radiation pneumonitis (AUC > 0.93, p < 0.01). Pairing of an anatomic and functional dosimetric parameter (e.g., MLD and pMLD{sub 70%}) may further improve prediction accuracy. Not all individuals with high anatomic lung dose (MLD > 13.6 GyEQD2{sub lung}, 19.3 Gy for patients receiving 60 Gy in 30 fractions) developed radiation pneumonitis, but all individuals who also had high mean dose to perfused lung (pMLD{sub 70%} > 13.3 GyEQD2) developed radiation pneumonitis. The preliminary application of this framework revealed differences between anatomic and perfused lung dosimetry in this limited patient cohort. The addition of perfused lung parameters may help risk stratify patients for radiation pneumonitis, especially in treatment plans with high anatomic mean lung dose. Further investigations are warranted. (orig.) [German] Erstellung und Anwendung eines Rahmenwerks zur Vorhersage symptomatischer Strahlenpneumonitis bei Patienten mit einer Thorax-Bestrahlung anhand anatomischer und perfundierter Lungendosis-Volumen-Parameter in der

  8. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Barocka, A.; Feistel, H.; Ebert, D.; Lungershausen, E.

    1993-01-01

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D 2 and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.) [de

  9. Brain SPECT in children

    International Nuclear Information System (INIS)

    Guyot, M.; Baulieu, J.L.

    1996-01-01

    Brain SPECT in child involves specific trends regarding the patient cooperation, irradiation, resolution and especially interpretation because of the rapid scintigraphic modifications related to the brain maturation. In a general nuclear medicine department, child brain SPECT represents about 2 % of the activity. The choice indications are the perfusion children: thallium and MIBI in brain tumours, pharmacological and neuropsychological interventions. In the future, brain dedicated detectors and new radiopharmaceuticals will promote the development of brain SPECT in children. (author)

  10. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology

    Science.gov (United States)

    Erlandsson, Kjell; Kacperski, Krzysztof; van Gramberg, Dean; Hutton, Brian F.

    2009-05-01

    D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a β-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s-1 MBq-1 per head (99mTc, 10 cm) (CS: 72 s-1 MBq-1), and the tomographic sensitivity in the heart region was in the range 647-1107 s-1 MBq-1 (CS: 141 s-1 MBq-1). The count rate increased linearly with increasing activity up to 1.44 M s-1. The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.

  11. Brain SPECT in childhood

    International Nuclear Information System (INIS)

    Tranquart, F.; Saliba, E.; Prunier, C.; Baulieu, F.; Besnard, J.C.; Guilloteau, D.; Baulieu, J.L.

    2001-01-01

    The modalities and the indications of perfusion and neurotransmission SPECT in childhood are presented. The perfusion as well as neurotransmission tracers have not yet authorization for use in children; they have to be used by prescription of magistral preparation or in research protocols. The radioprotection rules have to be strictly respected. The most frequent indication of perfusion SPECT is pharmacologically resistant epilepsy; the ictal SPECT before surgery allows the localization of the epileptogenic focus. Other indications are relevant in the prognosis of neonatal anoxia and encephalitis. In psychiatric disorders, especially in autism, the interest is the physiopathological approach of the brain dysfunctions. The neurotransmission SPECT is emerging as a consequence of the development of new radiotracer, as the dopaminergic system ligands. The decrease of the dopamine D2 receptors in the striatum can be imaged and quantified in the neonate. The lesions of dopamine system seem to be a consequence of the neonatal hypoxia-ischemia and it is predictive of motor sequelae. Brain SPECT should become a routine examination in child neurologic and psychiatric disorders. (authors)

  12. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  13. Radiation risk and protection of patients in clinical SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar; Nekolla, Elke A.; Nosske, Dietmar [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Borowski, Markus [Klinikum Braunschweig, Institute of Radiation Diagnostics and Nuclear Medicine, Braunschweig (Germany)

    2014-05-15

    Clinical studies have demonstrated that hybrid single photon emission computed tomography (SPECT)/CT for various diagnostic issues has an added value as compared to SPECT alone. However, the combined acquisition of functional and anatomical images can substantially increase radiation exposure to patients, in particular when using a hybrid system with diagnostic CT capabilities. It is, therefore, essential to carefully balance the diagnostic needs and radiation protection requirements. To this end, the evidence on health effects induced by ionizing radiation is outlined. In addition, the essential concepts for estimating radiation doses and lifetime attributable cancer risks associated with SPECT/CT examinations are presented taking into account both the new recommendations of the International Commission on Radiological Protection (ICRP) as well as the most recent radiation risk models. Representative values of effective dose and lifetime attributable risk are reported for ten frequently used SPECT radiopharmaceuticals and five fully diagnostic partial-body CT examinations. A diagnostic CT scan acquired as part of a combined SPECT/CT examination contributes considerably to, and for some applications even dominates, the total patient exposure. For the common SPECT and CT examinations considered in this study, the lifetime attributable risk of developing a radiation-related cancer is less than 0.27 %/0.37 % for men/women older than 16 years, respectively, and decreases markedly with increasing age at exposure. Since there is no clinical indication for a SPECT/CT examination unless an emission scan has been indicated, the issue on justification comes down to the question of whether it is necessary to additionally acquire a low-dose CT for attenuation correction and anatomical localization of tracer uptake or even a fully diagnostic CT. In any case, SPECT/CT studies have to be optimized, e.g. by adapting dose reduction measures from state-of-the-art CT practice, and

  14. Anything wrong with brain SPECT? Not really

    International Nuclear Information System (INIS)

    Pavel, D.G.; Davis, G.; Craita, I.; Liu, P.

    2002-01-01

    Aim: Despite increased evidence about the usefulness of Brain SPECT in Neuro-Psychiatry, it continues to represent only a low percentage of Nuclear Medicine procedures. The prevalent perception is that it is an inadequate diagnostic tool, and/or is not changing patient management. There are objective reasons for this, as the lack of awareness by Psychiatrists about the value of SPECT, but most important is the frequently poor quality of images provided. This can be due to inadequate gamma cameras but is mostly due to poor quality software. Materials and Methods: High resolution brain SPECT via triple head gamma camera, super-high resolution fan beam collimator and Tc-HMPAO. A combination of commercial software and local optimization was used for the final displays as well as for realignment of sequential brain SPECT studies. Results: We found out that 6 basic software improvements are needed to generate a final display where features can be clearly distinguished and which can be also easily assimilated by the referring physician. 1) Color scales: simple and efficient tools needed to generate user friendly and semiquantitative color shades as needed. Unfortunately various color scales may be needed depending on printer and paper used. 2): 3 D displays allowing, multiple standardized thresholdings, any number of groupings, differential coloring (with functional meaning) and adequate labeling. Should be completely or at least mostly automatic. 3) Automatic realignment of sequential studies: such programs exist in various forms (free WWW versions, proprietary Beta versions, etc.) but are still not supplied by the gamma camera vendors for general use. Should provide SPECT -SPECT and SPECT MRI options. 4) Localization of structures and slices a) Triangulation of structures and b) Identification of section location. 5) Graphics improvement for generating any number of optimized summary displays to accompany reports. 6) Availability of voxel based quantification software

  15. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Paulo Henrique Silva; Souza, Thiago Ferreira de; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Lima, Mariana da Cunha Lopes de; Santos, Allan Oliveira; Ramos, Celso Darío, E-mail: paulohsm42@gmail.com [Universidade de Campinas (UNICAMP), SP (Brazil). Escola de Medicina; Mengatti Jair [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-11-15

    Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ({sup 67}Ga) citrate scintigraphy. Materials And Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of {sup 99m}Tc-EDDA-HYNIC-TOC, and 21 after injection of {sup 111}In-DTPA-octreotide. All patients also underwent {sup 67}Ga citrate imaging, except for one patient who died before the {sup 67}Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by {sup 67}Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than {sup 67}Ga uptake in 11 of the 20 patients with positive images and similar to {sup 67}Ga uptake in the other 9 patients. The only patient who did not undergo {sup 67}Ga scintigraphy underwent {sup 99m}Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with {sup 99m}Tc-EDDA-HYNIC-TOC or {sup 111}In-DTPA-octreotide seems to be a good alternative to {sup 67}Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. (author)

  16. The manifestation of 18F-FDG imaging of coincidence SPECT in benign pulmonary diseases

    International Nuclear Information System (INIS)

    Miao Jisheng; Liu Jinjun; Wu Jiyong; Pan Huizhong; Wang Huoqiang; Shen Yi; Shi Degang

    2001-01-01

    Objective: To study the uptake of the 18 F-FDG in the benign pulmonary diseases with dual head SPECT coincidence detection system. Methods: Scanning were performed with dual head SPECT coincidence detection system for patients with pulmonary diseases,the uptake and the imaging characteristic of the diseases were analysed. Results: 1) In 28 tuberculosis (TB) patients, 19 cases with a negative imaging (68%, 19/28), whereas 9 cases with a positive result (32%, 9/28). The T/N value of the TB is 1.7 +- 1.2, but the T/N of the lung cancer is 4.1 +- 2.4, significantly different from them. In the skin PPD test, 9 cases with positive scans showed a 16.2 (12 - 22) mm diameter red spot, but 7 cases of negative scans with a 8.6 (0 - 15) mm diameter, both also have a significant difference. 2) Out of the 8 patients suffered from sarcoidosis, among them 5 active stage with positive scans, whereas another 3 remission cases with negative results. 3) In 18 inflammation cases, positive imagings were showed in 6 patients with cryptococcosis, mycoplasma pneumonia, mycosis, organized pneumonia, lung abscess and bacteria pneumonia. Conclusions: In some benign pulmonary diseases, 18 F-FDG imaging can be positive also. Analysing the characteristic of the imaging could rise specificity in lung cancer and also give some new clues to treatment of these benign pulmonary diseases

  17. The effect of patient-specific factors on radiation-induced regional lung injury

    International Nuclear Information System (INIS)

    Garipagaoglu, Melahat; Munley, Michael T.; Hollis, Donna; Poulson, Jean M.; Bentel, Gunilla C.; Sibley, Gregory; Anscher, Mitchell S.; Fan Ming; Jaszczak, Ronald J.; Coleman, R. Edward; Marks, Lawrence B.

    1999-01-01

    Purpose: To assess the impact of patient-specific factors on radiation (RT)-induced reductions in regional lung perfusion. Methods: Fifty patients (32 lung carcinoma, 7 Hodgkin's disease, 9 breast carcinoma and 2 other thoracic tumors) had pre-RT and ≥24-week post-RT single photon emission computed tomography (SPECT) perfusion images to assess the dose dependence of RT-induced reductions in regional lung perfusion. The SPECT data were analyzed using a normalized and non-normalized approach. Furthermore, two different mathematical methods were used to assess the impact of patient-specific factors on the dose-response curve (DRC). First, DRCs for different patient subgroups were generated and compared. Second, in a more formal statistical approach, individual DRCs for regional lung injury for each patient were fit to a linear-quadratic model (reduction = coefficient 1 x dose + coefficient 2 x dose 2 ). Multiple patient-specific factors including tobacco history, pre-RT diffusion capacity to carbon monoxide (DLCO), transforming growth factor-beta (TGF-β), chemotherapy exposure, disease type, and mean lung dose were explored in a multivariate analysis to assess their impact on the coefficients. Results: None of the variables tested had a consistent impact on the radiation sensitivity of regional lung (i.e., the slope of the DRC). In the formal statistical analysis, there was a suggestion of a slight increase in radiation sensitivity in the dose range >40 Gy for nonsmokers (vs. smokers) and in those receiving chemotherapy (vs. no chemotherapy). However, this finding was very dependent on the specific statistical and normalization method used. Conclusion: Patient-specific factors do not have a dramatic effect on RT-induced reduction in regional lung perfusion. Additional studies are underway to better clarify this issue. We continue to postulate that patient-specific factors will impact on how the summation of regional injury translates into whole organ injury

  18. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    International Nuclear Information System (INIS)

    Lee, D. S.; Lee, S. K.; Jeong, J. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study

  19. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D S; Lee, S K; Jeong, J K; Lee, M C; Ko, C S [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1997-07-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study.

  20. SPECT/CT for staging and treatment monitoring in oncology. Applications in differentiated thyroid cancer and liver tumors; SPECT/CT zum initialen Staging und Therapiemonitoring in der Onkologie. Indikationen beim differenzierten Schilddruesenkarzinom und bei Lebertumoren

    Energy Technology Data Exchange (ETDEWEB)

    Weber, K.; Berger, F.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Innenstadt, Institut fuer Klinische Radiologie, Muenchen (Germany); Mustafa, M.; Bartenstein, P.; Haug, A. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Klinik und Poliklinik fuer Nuklearmedizin, Muenchen (Germany)

    2012-07-15

    Hybrid imaging of function and morphology has gained significant importance for lesion detection and treatment monitoring in oncology. In patients with differentiated thyroid carcinoma (DTC) a planar whole body scan is carried out after radioiodine therapy (RIT) for staging. However, due to limited spatial resolution the diagnostic accuracy of this scintigraphy method is impaired. Radioembolization utilizing {sup 90}Yttrium loaded micro-spheres by selective internal radiotherapy (SIRT) allows a minor invasive therapy of primary and secondary liver tumors. In order to avoid side effects of the micro-spheres caused by an outflow into intestines, stomach or lungs, imaging the arteries supplying the liver has to be performed by means of technetium-99m macroaggregated albumin ({sup 99m}Tc-MAA) and scintigraphy. The limited morphological information supplied by scintigraphy is again a challenge in treatment monitoring. {sup 131}Iodine whole body scanning is used for staging in patients with DTC 3-4 days after ablation. Monitoring of the tumor marker thyroglobulin and selective radioiodine whole body scans are available for patients with a high risk profile in the further follow-up with imaging of the arteries supplying the liver by means of {sup 99m}Tc-MAA scintigraphy in preparation of SIRT. Single photon emission computed tomography/computed tomography (SPECT/CT) of the neck and thorax with a therapeutic activity of radioiodine for staging after ablation. Techniques include imaging of arteries supplying the liver by means of {sup 99m}Tc-MAA SPECT/CT before SIRT and evaluation and quantification of the uptake of liver tumors, especially in comparison to the uptake of liver parenchyma by means of SPECT/CT. Due to the integration of combined functional and morphological information SPECT/CT can be used to characterize the morphology and iodine uptake of lesions more accurately, resulting in optimized staging in patients with DTC in comparison to whole body iodine scans

  1. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  2. The utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for assessment of lung lesions in patients with neuroendocrine tumors.

    Science.gov (United States)

    Pavlovic, S; Artiko, V; Sobic-Saranovic, D; Damjanovic, S; Popovic, B; Jakovic, R; Petrasinovic, Z; Jaksic, E; Todorovic-Tirnanic, M; Saranovic, D; Micev, M; Novosel, S; Nikolic, N; Obradovic, V

    2010-01-01

    Our aim was to assess clinical utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for evaluation of lung lesions in patients with neuroendocrine tumors (NETs). Single photon emission computed tomography (SPECT) of the thorax and whole body scintigraphy were performed in 34 patients using 99mTc-EDDA/HYNIC-TOC. Visual assessment was complemented by semiquantitative evaluation based on tumor to non-tumor (T/NT) ratio. Clinical, laboratory, and histological findings served as the standard for comparison. Enhanced tracer uptake was observed on both SPECT and whole body scintigraphy in 29 of 34 patients (88% sensitivity). T/NT ratios were significantly higher on SPECT than whole body images (2.96+/-1.07 vs.1.70+/-0.43, p 99mTc-EDDA/Hynic-TOC, lung involvement of NETs, T/NT ratio.

  3. Ictal and interictal SPECT imaging of 8 patients with symptomatic partial epilepsy

    International Nuclear Information System (INIS)

    Motooka, Hiromichi

    1993-01-01

    Although epileptic discharges such as spike, spike and wave complex, sharp wave, and sharp and wave complex can be recorded by interictal scalp electroencephalography (EEG) in many patients with epilepsy, recent studies have demonstrated that no epileptic discharges can be recorded by interictal and ictal scalp EEGs in some patients who clinically exhibit epileptic seizures. Accordingly scalp EEG is not always helpful for diagnosing epilepsy or identifying the epileptic foci in the brain in these patients. Recently, studies using single photon emission computed tomography (SPECT) have been performed for patients with epilepsy and evidence that epileptic foci can be identified by changes in the regional cerebral blood flow (rCBF) seen on SPECT scanning have been accumulated. In the present study, therefore, 8 patients with medically intractable partial seizures were simultaneously or independently investigated by the recordings of scalp EEG and SPECT scanning during the interictal and ictal period. N-isopropyl-p[ 123 I]-iodoamphetamine ( 123 I-IMP) was used for SPECT scanning for 7 patients and 99m Tc-d,l-hexamethyl-propyleneamineoxime ( 99m Tc-HMPAO) for 1 patient. An increase in rCBF (hyperperfusion) or decrease in rCBF (hypoperfusion) were found in 4 patients by interictal SPECT imaging and in all patients by ictal SPECT imaging although epileptic discharges were observed in 3 patients by interictal scalp EEG and 5 patients by ictal scalp EEG. The findings of the present study indicate that ictal SPECT scanning is more useful for diagnosing epilepsy and identifying the epileptic foci in the brain than ictal scalp EEG. (author)

  4. Improved quantitative 90 Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling.

    Science.gov (United States)

    Dewaraja, Yuni K; Chun, Se Young; Srinivasa, Ravi N; Kaza, Ravi K; Cuneo, Kyle C; Majdalany, Bill S; Novelli, Paula M; Ljungberg, Michael; Fessler, Jeffrey A

    2017-12-01

    In 90 Y microsphere radioembolization (RE), accurate post-therapy imaging-based dosimetry is important for establishing absorbed dose versus outcome relationships for developing future treatment planning strategies. Additionally, accurately assessing microsphere distributions is important because of concerns for unexpected activity deposition outside the liver. Quantitative 90 Y imaging by either SPECT or PET is challenging. In 90 Y SPECT model based methods are necessary for scatter correction because energy window-based methods are not feasible with the continuous bremsstrahlung energy spectrum. The objective of this work was to implement and evaluate a scatter estimation method for accurate 90 Y bremsstrahlung SPECT/CT imaging. Since a fully Monte Carlo (MC) approach to 90 Y SPECT reconstruction is computationally very demanding, in the present study the scatter estimate generated by a MC simulator was combined with an analytical projector in the 3D OS-EM reconstruction model. A single window (105 to 195-keV) was used for both the acquisition and the projector modeling. A liver/lung torso phantom with intrahepatic lesions and low-uptake extrahepatic objects was imaged to evaluate SPECT/CT reconstruction without and with scatter correction. Clinical application was demonstrated by applying the reconstruction approach to five patients treated with RE to determine lesion and normal liver activity concentrations using a (liver) relative calibration. There was convergence of the scatter estimate after just two updates, greatly reducing computational requirements. In the phantom study, compared with reconstruction without scatter correction, with MC scatter modeling there was substantial improvement in activity recovery in intrahepatic lesions (from > 55% to > 86%), normal liver (from 113% to 104%), and lungs (from 227% to 104%) with only a small degradation in noise (13% vs. 17%). Similarly, with scatter modeling contrast improved substantially both visually and in

  5. Quantitative 177Lu-SPECT/CT imaging and validation of a commercial dosimetry software

    International Nuclear Information System (INIS)

    D'Ambrosio, L.; Aloj, L.; Morisco, A.; Aurilio, M.; Prisco, A.; Di Gennaro, F.; Lastoria, S.; Madesani, D.

    2015-01-01

    activity concentration measured in the spheres depended on the reconstruction parameter and for the smallest sphere the accuracy increased with increasing numbers of iterations and subsets. The residence time range was 0.33-1.46 hours for lungs, 0.57-3.54 hours for spleen, 0.93-3.58 hours for kidneys and 3.74-8.33 hours for liver. The mean absorbed dose was 0.69 Gy/GBq for liver, 0.76 Gy/GBq for spleen, 0.55 Gy/GBq for kidneys and 0.08 Gy/GBq for lungs. Conclusion: quantitative SPECT with Lu 177 has high accuracy both in our phantom and in clinical practice. Dosimetry tool-kit simplifies the procedure for quantifying absorbed dose reduces the processing time and improves accuracy of results compared to manual Methods. Software implementation of partial volume correction in the dosimetric work-flow is recommended to obtain more accurate dose estimations. (authors)

  6. HMPAO-SPECT in cerebral seizures

    International Nuclear Information System (INIS)

    Gruenwald, F.; Bockisch, A.; Reichmann, K.; Ammari, B.; Hotze, A.; Biersack, H.J.; Durwen, H.; Buelau, P.; Elger, C.E.; Rohde, A.; Penin, H.

    1988-01-01

    In nine patients with suspected psychogenic seizures and in three patients with proven epileptic seizures HMPAO-SPECT was performed prior to and during seizure. In the patients with lateron-proven psychogenic seizures no, or only slight, changes of regional cerebral blood flow were found. Patients with proven epilepsy revealed partly normal findings interictally but during seizure a markedly increased circumscript blood flow was found in all patients. Even though PET is superior to SPECT with respect to spatial resolution, in the diagnosis of seizures HMPAO-SPECT has the advantage of enabling injection of the tracer during the seizure and the performance of the SPECT study subsequently. (orig.) [de

  7. The role of three dimensional functional lung imaging in radiation treatment planning: the functional dose-volume histogram

    International Nuclear Information System (INIS)

    Marks, Lawrence B.; Spencer, David P.; Sherouse, George W.; Bentel, Gunilla; Clough, Robert; Vann, Karen; Jaszczak, Ronald; Coleman, R. Edward; Prosnitz, Leonard R.

    1995-01-01

    Purpose: During thoracic irradiation (XRT), treatment fields are usually designed to minimize the volume of nontumor-containing lung included. Generally, functional heterogeneities within the lung are not considered. The three dimensional (3D) functional information provided by single photon emission computed tomography (SPECT) lung perfusion scans might be useful in designing beams that minimize incidental irradiation of functioning lung tissue. We herein review the pretreatment SPECT scans in 86 patients (56 with lung cancer) to determine which are likely to benefit from this technology. Methods and Materials: Prior to thoracic XRT, SPECT lung perfusion scans were obtained following the intravenous injection of ∼4 mCi of 99m Tc-labeled macro-aggregated albumin. The presence of areas of decreased perfusion, their location relative to the tumor, and the potential clinical usefulness of their recognition, were scored. Patients were grouped and compared (two-tailed chi-square) based on clinical factors. Conventional dose-volume histograms (DVHs) and functional DVHs (DV F Hs) are calculated based on the dose distribution throughout the computed tomography (CT)-defined lung and SPECT-defined perfused lung, respectively. Results: Among 56 lung cancer patients, decreases in perfusion were observed at the tumor, adjacent to the tumor, and separate from the tumor in 94%, 74%, and 42% of patients, respectively. Perfusion defects adjacent to the tumor were often large with centrally placed tumors. Hypoperfusion in regions separate from the tumor were statistically most common in patients with relatively poor pulmonary function and chronic obstructive pulmonary disease (COPD). Considering all SPECT defects adjacent to and separate from the tumor, corresponding CT abnormalities were seen in only ∼50% and 20% of patients, respectively, and were generally not as impressive. Following XRT, hypoperfusion at and separate from the tumor persisted, while defects adjacent to the

  8. Can perfusion SPECT aid CTPA interpretation?

    International Nuclear Information System (INIS)

    Gradinscak, D. J.; Roach, P.; Bailey, E.; Kueh, S.

    2009-01-01

    Full text:Objective: To determine whether fusion of perfusion SPECT and CTPA improves the diagnostic accuracy of CTPA. Methods: 35 patients with suspected PE who underwent both CTPA and SPECT V/Q within 48 hours were included. Of these, the majority (n=30) had PE as determined by the V/Q SPECT scan and the others (n=5) were negative for PE. The clinical reports of CTPA were reviewed and pulmonary emboli tabulated based on anatomical location. A second radiologist, blinded to the results of the clinical read and the V/Q SPECT scan, reviewed the CTPA with and without perfusion SPECT fusion for assistance. Results: A total 57 PE were reported on the clinical reports and 60 PE identified on the blinded read. Fused CTPA/perfursion SPECT images identified a further 5 PE not identified on the clinical read (8% increase) and 2 PE not identified on the blinded read (3% increase). The additional emboli detected resulted in a change in final diagnosis from PE negative to PE positive in 2 patients (6%) compared with the clinical read and 1 patient (3%) compared with the blinded read without SPECT fusion. Conclusion: Fused CTPA-SPECT perfusion improves the sensitivity of CTPA for the detection of PE in a small number of patients. Fused data may help guide the radiologist to identify sites of PE on CTPA.

  9. Diagnostic role of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases.

    Science.gov (United States)

    Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi

    2014-01-01

    The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.

  10. 99mTc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    International Nuclear Information System (INIS)

    Yang, Hyung In; Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon

    1994-01-01

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  11. Sequential SPECT/CT imaging starting with stress SPECT in patients with left bundle branch block suspected for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Engbers, Elsemiek M.; Mouden, Mohamed [Isala, Department of Cardiology, Zwolle (Netherlands); Isala, Department of Nuclear Medicine, Zwolle (Netherlands); Timmer, Jorik R.; Ottervanger, Jan Paul [Isala, Department of Cardiology, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala, Department of Nuclear Medicine, Zwolle (Netherlands)

    2017-01-15

    To investigate the impact of left bundle branch block (LBBB) on sequential single photon emission computed tomography (SPECT)/ CT imaging starting with stress-first SPECT. Consecutive symptomatic low- to intermediate-risk patients without a history of coronary artery disease (CAD) referred for SPECT/CT were included from an observational registry. If stress SPECT was abnormal, additional rest SPECT and, if feasible, coronary CT angiography (CCTA) were acquired. Of the 5,018 patients, 218 (4.3 %) demonstrated LBBB. Patients with LBBB were slightly older than patients without LBBB (65±12 vs. 61±11 years, p<0.001). Stress SPECT was more frequently abnormal in patients with LBBB (82 % vs. 46 %, p<0.001). After reviewing stress and rest images, SPECT was normal in 43 % of the patients with LBBB, compared to 77 % of the patients without LBBB (p<0.001). Sixty-four of the 124 patients with LBBB and abnormal stress-rest SPECT underwent CCTA (52 %), which could exclude obstructive CAD in 46 of the patients (72 %). Sequential SPECT/CT imaging starting with stress SPECT is not the optimal imaging protocol in patients with LBBB, as the majority of these patients have potentially false-positive stress SPECT. First-line testing using CCTA may be more appropriate in low- to intermediate-risk patients with LBBB. (orig.)

  12. Methods of gated-blood-pool-spect data processing

    International Nuclear Information System (INIS)

    Kosa, I.; Mester, J.; Tanaka, M.; Csernay, L.; Mate, E.; Szasz, K.

    1991-01-01

    Three techniques of gated SPECT were evaluated. The methods of Integral SPECT (ISPECT), enddyastole-endsystole SPECT (ED-ES SPECT) and Fourier SPECT were adapted and developed on the Hungarian nuclear medicine data processing system microSEGAMS. The methods are based on data reduction before back projection which results in processing times acceptable for the clinical routine. The clinical performance of the introduced techniques was tested in 10 patients with old posterior myocardial infarction and in 5 patients without cardiac disease. The left ventricular ejection faction determined by ISPECT correlated well with the planar values. The correlation coefficient was 0.89. The correlation coefficient of EF values determined by ED-ES SPECT and planar radionuclide ventriculography was lower (0.70). For the identification of left ventricular wall motion abnormalities ED-ES SPECT and Fourier SPECT exhibited a favourable performance, but ISPECT only moderate suitability. In the detection of regional phase delay Fourier-SPECT demonstrated higher sensitivity than the planar radionuclide ventriculography. (author) 4 refs.; 3 figs.; 2 tabs

  13. Brain SPECT with 123I-isopropyl amphetamine in epilepsy

    International Nuclear Information System (INIS)

    Biersack, H.J.; Reske, S.N.; Rasche, A.; Reichmann, K.; Winkler, C.

    1983-01-01

    Ten patients were studied with N-isopropyl I-123 p-iodoamphetamine. Single photon emission computed tomography (SPECT) was carried out by hand of a rotating gamma camera system (Gammatome T9000/CGR, high resolution collimator). During 1 rotation (360 0 ) 64 frames (4k matrix) were acquired within 20 min 1 hour after injection of 6.5 mCi I-123 labeled amphetamine. The content of I-124 was less than 2%. After reconstruction of transverse slices coronar and sagittal reconstructions were rapidly performed using an array processor. Nine patients suffered from epilepsy and one from severe migraine. Excellent differentiation between gray and white matter of the cerebral cortex and the basal ganglia was evident in all of the cases. In 2 out of 3 patients with epilepsy and negative CT results SPECT revealed circumscribed areas with increased amphetamine uptake in accordance with the EEG findings. In 4 out of 6 cases with positive CT findings SPECT lesions with diminished amphetamine uptake could be established. One patient with severe migraine showed focal increased amphetamine uptake in accordance with the respective clinical results. (orig.)

  14. Fibroelastic pseudotumor elastofibroma dorsi detected by 18F-FDG PET/CT scan and by postherapy radioiodine SPECT/CT.

    Science.gov (United States)

    Oporto, M; Cepa, F; Orta, N; Rubí, S; Navalón, H; Peña, C

    Radioiodine uptake in the thyroid tissue, metastasis of differentiated thyroid cancer (DTC), and in other tissues, depends on the expression of sodium-iodide symporter (NIS). Vascular permeability, effusions, inflammation, and other mechanisms may also play a role in the accumulation of radioactive iodine. A 63-year-old woman underwent radioiodine therapy, as well as a post-therapy whole-body scan, as she was suspected of having lung metastasis from thyroid carcinoma. The scan not only showed uptake at the lung metastasis but also a faint diffuse bilateral uptake in the posterior thorax. On SPECT/CT this uptake was located in a known Elastofibroma Dorsi (ED) previously diagnosed by contrast CT and viewed in a FDG PET/CT. The radioiodine uptake in ED, especially if typical, is not a diagnostic problem in SPECT/CT study, but can be misleading in a study limited to a few planar images, particularly if the uptake occurs asymmetrically, or ED is located in a unsuspected area. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  15. SPECT data acquisition and image reconstruction in a stationary small animal SPECT/MRI system

    Science.gov (United States)

    Xu, Jingyan; Chen, Si; Yu, Jianhua; Meier, Dirk; Wagenaar, Douglas J.; Patt, Bradley E.; Tsui, Benjamin M. W.

    2010-04-01

    The goal of the study was to investigate data acquisition strategies and image reconstruction methods for a stationary SPECT insert that can operate inside an MRI scanner with a 12 cm bore diameter for simultaneous SPECT/MRI imaging of small animals. The SPECT insert consists of 3 octagonal rings of 8 MR-compatible CZT detectors per ring surrounding a multi-pinhole (MPH) collimator sleeve. Each pinhole is constructed to project the field-of-view (FOV) to one CZT detector. All 24 pinholes are focused to a cylindrical FOV of 25 mm in diameter and 34 mm in length. The data acquisition strategies we evaluated were optional collimator rotations to improve tomographic sampling; and the image reconstruction methods were iterative ML-EM with and without compensation for the geometric response function (GRF) of the MPH collimator. For this purpose, we developed an analytic simulator that calculates the system matrix with the GRF models of the MPH collimator. The simulator was used to generate projection data of a digital rod phantom with pinhole aperture sizes of 1 mm and 2 mm and with different collimator rotation patterns. Iterative ML-EM reconstruction with and without GRF compensation were used to reconstruct the projection data from the central ring of 8 detectors only, and from all 24 detectors. Our results indicated that without GRF compensation and at the default design of 24 projection views, the reconstructed images had significant artifacts. Accurate GRF compensation substantially improved the reconstructed image resolution and reduced image artifacts. With accurate GRF compensation, useful reconstructed images can be obtained using 24 projection views only. This last finding potentially enables dynamic SPECT (and/or MRI) studies in small animals, one of many possible application areas of the SPECT/MRI system. Further research efforts are warranted including experimentally measuring the system matrix for improved geometrical accuracy, incorporating the co

  16. Investigations of (99m)Tc-labeled glucarate as a SPECT radiotracer for non-small cell lung cancer (NSCLC) and potential tumor uptake mechanism.

    Science.gov (United States)

    Meng, Lanfang; Xiu, Yan; Li, Yanli; Xu, Xiaobo; Li, Shanqun; Li, Xiao; Pak, Koon Y; Shi, Hongcheng; Cheng, Dengfeng

    2015-07-01

    This study attempted to evaluate the feasibility of (99m)Tc-labeled glucarate ((99m)Tc-GLA) imaging in non-small cell lung cancer (NSCLC) and the potential tumor uptake mechanism. Cell lysates from two NSCLC cell lines, H292 and H1975, were immunoblotted with anti-glucose transporter 5 (GLUT5) antibody for Western blotting. Thereafter, the two cell lines were used to examine cellular uptake of (99m)Tc-GLA with or without fructose. SPECT/CT imaging studies were performed on small animals bearing H292 and H1975 tumors. Biodistribution studies were also conducted to achieve accurate tissue uptake of this tracer in two tumor models. Hematoxylin & eosin (H&E) staining and GLUT5, Ki67 and cytokeratin-7 (CK-7) immunohistochemistry (IHC) analysis were further investigated on tumor tissues. In Western blotting, H292 cells showed higher levels of GLUT5 compared to the H1975 cells. Meanwhile, the in vitro cell assays indicated GLUT5-dependent uptake of (99m)Tc-GLA in H292 and H1975 cells. The fructose competition assays showed a significant decrease in (99m)Tc-GLA uptake by H292 and H1975 cells when fructose was added. The (99m)Tc-GLA accumulation was as much as two-fold higher in H292 implanted tumors than in H1975 implanted tumors. (99m)Tc-GLA exhibited rapid clearance pharmacokinetics and reasonable uptake in human NSCLC H292 (1.69±0.37 ID%/g) and H1975 (0.89±0.06 ID%/g) implanted tumors at 30min post injection. Finally, the expression of GLUT5, Ki67 and CK-7 on tumor tissues also exhibited positive correlation with the in vitro cell test results and in vivo SPECT/CT imaging results in xenograft tumors. Both in vitro and ex vivo studies demonstrated that the uptake of (99m)Tc-GLA in NSCLC is highly related to GLUT5 expression. Imaging and further IHC results support that (99m)Tc-GLA could be a promising SPECT imaging agent for NSCLC diagnosis and prognosis evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Kombineret ventilations/perfusions-SPECT/CT er bedst til diagnostik af lungeemboli

    DEFF Research Database (Denmark)

    Gutte Borgwardt, Henrik; Mortensen, Jann; Kristoffersen, Ulrik Sloth

    2012-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer test and imaging with either lung scintigraphy or pulmonary multidetector computed tomography angiography (CTA). Which of the two methods to use in PE diagnostic has not been determined...... and very limited data comparing these modalities are available. With the use of hybrid scanners, ventilation/perfusion-single-photon-emission-tomography (V/Q-SPECT) in combination with low-dose CT without contrast enhancement is feasible and should probably be considered first-line imaging in diagnosing PE....

  18. Basic and technical research on lung cancer

    International Nuclear Information System (INIS)

    Miyamoto, Tadaaki

    2004-01-01

    In association with clinical study of carbon beam therapy for lung cancer, the basic research for lung cancer and the patients with this disease has been carried out for the past 10 years. With regard to lung damage by the carbon beams, firstly pulmonary function was measured and analyzed for the patients with stage I non-small cell lung cancer. Force expiratory volume in 1 second (FVE 1.0) and TLC (total lung capacity) was found to be reduced significantly at 6 and 12 months after therapy but the reduction rate was a little, which can support the safety of this treatment modality. Secondly, the regional lung damage by the beams was investigated by using correct fusion of CT images with carbon beam dose distribution, diagnostic follow-up CT images and blood flow and ventilation spect images. It demonstrated the graded decrease blood flow by dose and the compensatory increase of blood flow in the adjacent lobe of lung unexposed to irradiation. On the other hand, the biological study of carbon beam effects on lung cancer cells and tumors line was conducted. Firstly, by using 7 or 4 human lung cancer cell line, the radiosensitivity of carbon beams was compared with that of photons by different histological patterns. It was found that there was no essential difference in the sensitivity pattern for lung cancer histology between the carbon beams and photons though the former doubled the later in power. Secondly, by using IA cell lines among them, the dynamic of clonogenic cells (clonogen) in a nude tumor and the changes in its morphology following irradiation was investigated, clarifying that the clonogen proliferating under anoxic or hypoxic conditions played a pivotal role for tumor regrowth and stemmed from the different clone which had been genetically selected and developed under these conditions. The finding of clonogen becomes one of the evidence supporting the superiority of a single-dose radiotherapy to fractionated radiotherapy. (author)

  19. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  20. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  1. Genetic evidence linking lung cancer and COPD: a new perspective

    Directory of Open Access Journals (Sweden)

    Crapo JD

    2011-07-01

    Full Text Available Robert P Young1,4, Raewyn J Hopkins1, Gregory D Gamble1, Carol Etzel2, Randa El-Zein2, James D Crapo31Department of Medicine and School of Biological Sciences, University of Auckland, Auckland, New Zealand; 2Department of Epidemiology, UT MD Anderson Cancer Center, Houston, TX, USA; 3National Jewish Health, Denver, CO, USA; 4Synergenz Biosciences Ltd, Auckland, New ZealandAbstract: Epidemiological studies indicate that tobacco smoke exposure accounts for nearly 90% of cases of chronic obstructive pulmonary disease (COPD and lung cancer. However, genetic factors may explain why 10%–30% of smokers develop these complications. This perspective reviews the evidence suggesting that COPD is closely linked to susceptibility to lung cancer and outlines the potential relevance of this observation. Epidemiological studies show that COPD is the single most important risk factor for lung cancer among smokers and predates lung cancer in up to 80% of cases. Genome-wide association studies of lung cancer, lung function, and COPD have identified a number of overlapping “susceptibility” loci. With stringent phenotyping, it has recently been shown that several of these overlapping loci are independently associated with both COPD and lung cancer. These loci implicate genes underlying pulmonary inflammation and apoptotic processes mediated by the bronchial epithelium, and link COPD with lung cancer at a molecular genetic level. It is currently possible to derive risk models for lung cancer that incorporate lung cancer-specific genetic variants, recently identified “COPD-related” genetic variants, and clinical variables. Early studies suggest that single nucleotide polymorphism-based risk stratification of smokers might help better target novel prevention and early diagnostic strategies in lung cancer.Keywords: lung cancer, chronic obstructive pulmonary disease, association study, single nucleotide polymorphism, risk model

  2. Functional brain SPECT with 99mTc-HMPAO in the diagnosis of Alzheimer disease

    International Nuclear Information System (INIS)

    Urbanek, J.; Kupka, K.; Samal, M.; Jirak, R.; Obenberger, J.

    1998-01-01

    The explanatory power of perfusion diagrams obtained by the title technique was examined. In addition to the standard reconstruction procedure, a special reorientation procedure aimed at a differentiation of the hippocampus structure was applied. The study gave evidence of a high specificity and sensitivity of brain SPECT in the differential diagnosis of dementias. Multifactorial analysis of all available diagnostic techniques has borne out the dominant position of brain SPECT with 99m Tc-HMPAO, particularly when using special projection onto the hippocampus, and has led to the formulation of an examination algorithm where a combination of SPECT and MRI (and CT) enables DAT to be distinguished from dementias of other etiologies with a probability higher than 90%

  3. Evaluation of Mucociliary Clearance by Three Dimension Micro-CT-SPECT in Guinea Pig: Role of Bitter Taste Agonists.

    Science.gov (United States)

    Ortiz, Jose Luis; Ortiz, Amparo; Milara, Javier; Armengot, Miguel; Sanz, Celia; Compañ, Desamparados; Morcillo, Esteban; Cortijo, Julio

    2016-01-01

    Different image techniques have been used to analyze mucociliary clearance (MCC) in humans, but current small animal MCC analysis using in vivo imaging has not been well defined. Bitter taste receptor (T2R) agonists increase ciliary beat frequency (CBF) and cause bronchodilation but their effects in vivo are not well understood. This work analyzes in vivo nasal and bronchial MCC in guinea pig animals using three dimension (3D) micro-CT-SPECT images and evaluates the effect of T2R agonists. Intranasal macroaggreggates of albumin-Technetium 99 metastable (MAA-Tc99m) and lung nebulized Tc99m albumin nanocolloids were used to analyze the effect of T2R agonists on nasal and bronchial MCC respectively, using 3D micro-CT-SPECT in guinea pig. MAA-Tc99m showed a nasal mucociliary transport rate of 0.36 mm/min that was increased in presence of T2R agonist to 0.66 mm/min. Tc99m albumin nanocolloids were homogeneously distributed in the lung of guinea pig and cleared with time-dependence through the bronchi and trachea of guinea pig. T2R agonist increased bronchial MCC of Tc99m albumin nanocolloids. T2R agonists increased CBF in human nasal ciliated cells in vitro and induced bronchodilation in human bronchi ex vivo. In summary, T2R agonists increase MCC in vivo as assessed by 3D micro-CT-SPECT analysis.

  4. Clinical Utility of SPECT/CT Imaging Post-Radioiodine Therapy: Does It Enhance Patient Management in Thyroid Cancer?

    Science.gov (United States)

    Hassan, Fahim U; Mohan, Hosahalli K

    2015-12-01

    The aim of this study was to evaluate post-therapy iodine-131 single-photon emission computed tomography/computed tomography ((131)I-SPECT/CT) imaging in comparison to conventional planar (131)I whole-body imaging, and to assess its clinical impact on the management of patients. We retrospectively reviewed planar (131)I whole-body and (131)I-SPECT/CT imaging findings in 67 patients who underwent (131)I therapy for thyroid cancer. Two nuclear medicine physicians reviewed the scans independently. The foci of increased tracer uptake were identified in the neck, thorax and elsewhere. Within the neck, the foci of (131)I-increased uptake were graded qualitatively as probable or definite uptake in thyroid remnants and probable or definite uptake in the lymph nodes. Serum thyroglobulin level, histopathology and other imaging findings served as the reference standard. Of the 67 patients, 57 (85%) had radioiodine avid disease and 10 (15%) demonstrated non-radioiodine avid disease. Overall, post-therapy (131)I-SPECT/CT downstaged lymph node staging in 10 patients and upstaged it in 4 patients. This translated into a change of management for 9/57 (16%) patients with radioiodine avid disease. A change of management was observed in 5/10 patients with non-radioiodine avid disease confirmed in the post-(131)I-SPECT/CT study. Additionally, clinically significant findings such as incidental lung cancer, symptomatic pleural effusion and consolidation were also diagnosed in both groups of patients. In patients with thyroid cancer, (131)I-SPECT/CT is a valuable addition to standard post-therapy planar imaging. SPECT/CT also improved diagnostic confidence and provided crucial clinical information leading to change of management for a significant number of these patients.

  5. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  6. Comparison of Xenon-Enhanced Area-Detector CT and Krypton Ventilation SPECT/CT for Assessment of Pulmonary Functional Loss and Disease Severity in Smokers.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Takenaka, Daisuke; Kaminaga, Shigeo; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi

    2018-02-01

    The objective of this study was to compare the capability of xenon-enhanced area-detector CT (ADCT) performed with a subtraction technique and coregistered 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity in smokers. Forty-six consecutive smokers (32 men and 14 women; mean age, 67.0 years) underwent prospective unenhanced and xenon-enhanced ADCT, 81m Kr-ventilation SPECT/CT, and pulmonary function tests. Disease severity was evaluated according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification. CT-based functional lung volume (FLV), the percentage of wall area to total airway area (WA%), and ventilated FLV on xenon-enhanced ADCT and SPECT/CT were calculated for each smoker. All indexes were correlated with percentage of forced expiratory volume in 1 second (%FEV 1 ) using step-wise regression analyses, and univariate and multivariate logistic regression analyses were performed. In addition, the diagnostic accuracy of the proposed model was compared with that of each radiologic index by means of McNemar analysis. Multivariate logistic regression showed that %FEV 1 was significantly affected (r = 0.77, r 2 = 0.59) by two factors: the first factor, ventilated FLV on xenon-enhanced ADCT (p < 0.0001); and the second factor, WA% (p = 0.004). Univariate logistic regression analyses indicated that all indexes significantly affected GOLD classification (p < 0.05). Multivariate logistic regression analyses revealed that ventilated FLV on xenon-enhanced ADCT and CT-based FLV significantly influenced GOLD classification (p < 0.0001). The diagnostic accuracy of the proposed model was significantly higher than that of ventilated FLV on SPECT/CT (p = 0.03) and WA% (p = 0.008). Xenon-enhanced ADCT is more effective than 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity.

  7. {sup 99m}Tc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hyung In [Kyunghee University Hospital, Seoul (Korea, Republic of); Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon [Seoul National University Hospital, Seoul (Korea, Republic of)

    1994-03-15

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  8. Clinical evaluation of SPECT in cerebrovascular disease

    International Nuclear Information System (INIS)

    Oshibuchi, Masao; Satoh, Mitsutaka; Kanda, Tetsuro; Nishi, Fumiaki; Yamane, Kanji; Fujimatsu, Masahiko; Edamitsu, Satoshi; Anno, Yasuro; Ohtake, Hisashi.

    1989-01-01

    In 131 patients with cerebrovascular disease, regional cerebral blood flow were determined by 123 I-IMP (N-isopropyl ( 123 I)-iodoamphetamine) or 99m Tc-HM-PAO ( 99m Tc (d, 1)-hexamethyl propyleneamine oxime) SPECT and findings were compared with those of X-CT or MRI. The perfusion deficit detected by SPECT was larger than the deficit by X-CT or MRI in every case. The perfusion deficit area was more clearly demonstrated by SPECT than by X-CT or MRI in patients with acute cerebral infarction. The hypoperfusion area determined by 123 I-IMP SPECT was wider than that by 99m Tc-HM-PAO SPECT. The crossed cerebellar diaschisis was observed in 56 out of 131 cases (43%). The results of operation were quantitatively evaluated by 123 I-IMP SPECT in 25 patients. (author)

  9. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    International Nuclear Information System (INIS)

    Lee, Sang Kun; Lee, Dong Soo

    2003-01-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test

  10. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Kun; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test.

  11. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Grova, C [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Jannin, P [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Biraben, A [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Buvat, I [INSERM U494, CHU Pitie Salpetriere, Paris (France); Benali, H [INSERM U494, CHU Pitie Salpetriere, Paris (France); Bernard, A M [Service de Medecine Nucleaire, Centre Eugene Marquis, Rennes (France); Scarabin, J M [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Gibaud, B [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France)

    2003-12-21

    Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathological SPECT data perfectly aligned with a high-resolution 3D T1-weighted MRI using realistic Monte Carlo simulations that closely reproduce the response of a SPECT imaging system. Anatomical input data for the SPECT simulations are obtained from this 3D T1-weighted MRI, while functional input data result from an inter-individual analysis of anatomically standardized SPECT data. The method makes it possible to control the 'brain perfusion' function by proposing a theoretical model of brain perfusion from measurements performed on real SPECT images. Our method provides an absolute gold standard for assessing MRI/SPECT registration method accuracy since, by construction, the SPECT data are perfectly registered with the MRI data. The proposed methodology has been applied to create a theoretical model of normal brain perfusion and ictal brain perfusion characteristic of mesial temporal lobe epilepsy. To approach realistic and unbiased perfusion models, real SPECT data were corrected for uniform attenuation, scatter and partial volume effect. An anatomic standardization was used to account for anatomic variability between subjects. Realistic simulations of normal and ictal SPECT deduced from these perfusion models are presented. The comparison of real and simulated SPECT images showed relative differences in regional activity concentration of less than 20% in most anatomical structures, for both normal and ictal data, suggesting realistic models of perfusion distributions for evaluation purposes. Inter-hemispheric asymmetry coefficients measured on simulated data were

  12. Role of post-therapy 131Iodine SPECT-CT in risk stratification and management of patients with differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Agarwal, K.; Bhattacharya, A.; Harishankar, C.N.B.; Manohar, K.; Mittal, B.R.

    2010-01-01

    Full text: To determine whether post therapy 131 I SPECT/CT changed the American Thyroid Association risk of recurrence classification and further management of the patients with differentiated thyroid carcinoma. Materials and Methods: In this prospective study, 33 consecutive patients with thyroid carcinoma (28 papillary, 4 follicular, 1 Hurthle cell) were included. Planar imaging and SPECT/CT were performed 4-7 days after the therapeutic administration of 1,221-5,180 MBq (33-140 mCi) of 131 I. SPECT/CT of the neck and upper chest were obtained for all subjects. Additional SPECT/CT scans of the abdomen or pelvis were acquired if planar imaging showed any abnormal focus of uptake. Planar and SPECT/CT images were interpreted independently, and sites of uptake were categorized as residual thyroid uptake, level VI cervical lymph node uptake, level II-V cervical lymph nodal uptake or distant metastasis. An experienced nuclear medicine physician determined if the imaging findings changed the patient's risk category and further management. Results: In 4 of 33 post surgical patients, SPECT/CT findings changed the initial ATA risk of recurrence classification. In 3 of these 4 patients, WB planar imaging showed distant metastases (1 in lung, 1 in spleen, 1 in left humerus), SPECT/CT confirming these to physiological uptake in breast and intestine and skin contamination respectively. This altered the risk of recurrence from high to intermediate category. In 1 of these 4 patients, WB planar imaging was suggestive of cervical lymph nodal metastasis, but SPECT/CT localized the abnormal focus of uptake to residual thyroid tissue, altering the risk of recurrence from intermediate to low. SPECT/CT changed the further post ablation management in 13 out of 33 patients. In 4/13 patients SPECT/CT detected cervical lymph nodes metastases, in 1/13 patient supraclavicular lymph node metastasis was detected, in 7/13 patients distant metastases was confirmed as physiological uptake or

  13. SP-ECT imaging and its physical study

    International Nuclear Information System (INIS)

    Kinoshita, Fujimi

    1983-01-01

    Recently, more than a hundred hospitals are provided with SPECT system for clinical examination in Japan. However, a standardization of measuring method and performance test of the systems is ont yet made. We have been studying some basic problems of SPECT system with special phantoms originaly designed by ourselves. We got a conclusion that a standardized phantom is necessary for comparing performances between SPECT systems. In clinical experiences with 3,332 cases, we think that SPECT image combined with conventional image presents much more informations for accurate diagnosis, especially in brain, bone and tumor imagings. Synthesized image of SPECT and XCT, double tracer image and transmission image are useful to visualize the body contour and the clinical diagnosis. (author)

  14. Brain SPECT with /sup 123/I-isopropyl amphetamine in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Biersack, H.J.; Reske, S.N.; Rasche, A.; Reichmann, K.; Winkler, C.; Froescher, W.; Kluenenberg, H.

    1983-04-01

    Ten patients were studied with N-isopropyl I-123 p-iodoamphetamine. Single photon emission computed tomography (SPECT) was carried out by hand of a rotating gamma camera system (Gammatome T9000/CGR, high resolution collimator). During 1 rotation (360/sup 0/) 64 frames (4k matrix) were acquired within 20 min 1 hour after injection of 6.5 mCi I-123 labeled amphetamine. The content of I-124 was less than 2%. After reconstruction of transverse slices coronar and sagittal reconstructions were rapidly performed using an array processor. Nine patients suffered from epilepsy and one from severe migraine. Excellent differentiation between gray and white matter of the cerebral cortex and the basal ganglia was evident in all of the cases. In 2 out of 3 patients with epilepsy and negative CT results SPECT revealed circumscribed areas with increased amphetamine uptake in accordance with the EEG findings. In 4 out of 6 cases with positive CT findings SPECT lesions with diminished amphetamine uptake could be established. One patient with severe migraine showed focal increased amphetamine uptake in accordance with the respective clinical results.

  15. Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study

    International Nuclear Information System (INIS)

    Genovesi, Dario; Giorgetti, Assuero; Gimelli, Alessia; Kusch, Annette; D'Aragona Tagliavia, Irene; Casagranda, Mirta; Marzullo, Paolo; Cannizzaro, Giorgio; Giubbini, Raffaele; Bertagna, Francesco; Fagioli, Giorgio; Rossi, Massimiliano; Romeo, Annadina; Bertolaccini, Pietro; Bonini, Rita

    2011-01-01

    In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of this multicentre study was to assess the impact of GSPECT and AC on the diagnostic performance of myocardial scintigraphy, according to patient's sex, body mass index (BMI) and site of coronary artery disease (CAD). We studied a group of 104 patients who underwent coronary angiography within 1 month before or after the SPECT study. Patients with a BMI > 27 were considered ''overweight''. Attenuation-corrected and standard GSPECT early images were randomly interpreted by three readers blinded to the clinical data. In the whole group, GSPECT and AC showed a diagnostic accuracy of 86.5% (sensitivity 82%, specificity 93%) and 77% (sensitivity 75.4%, specificity 81.4%), respectively (p < 0.05). In women, when anterior ischaemia was matched with CAD, AC failed to show any increase in specificity (AC 63.6% vs GSPECT 63.6%) with evident loss of sensitivity (AC 72.7% vs GSPECT 90.9%). AC significantly improved SPECT specificity in the identification of right CAD in overweight men (AC 100% vs GSPECT 66.7%, p <0.05). AC improved specificity in the evaluation of right CAD in overweight men. In the other evaluable subgroups specificity was not significantly affected while sensitivity was frequently reduced. (orig.)

  16. Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study

    Energy Technology Data Exchange (ETDEWEB)

    Genovesi, Dario; Giorgetti, Assuero; Gimelli, Alessia; Kusch, Annette; D' Aragona Tagliavia, Irene; Casagranda, Mirta; Marzullo, Paolo [Fondazione CNR-Regione Toscana ' ' G. Monasterio' ' , Nuclear Medicine, Pisa (Italy); Cannizzaro, Giorgio [A.O.V. Cervello, Nuclear Medicine, Palermo (Italy); Giubbini, Raffaele; Bertagna, Francesco [Spedali Civili, Nuclear Medicine, Brescia (Italy); Fagioli, Giorgio; Rossi, Massimiliano; Romeo, Annadina [Ospedale Maggiore, Nuclear Medicine, Bologna (Italy); Bertolaccini, Pietro; Bonini, Rita [Ospedale SS Giacomo e Cristoforo, Nuclear Medicine, Massa (Italy)

    2011-10-15

    In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of this multicentre study was to assess the impact of GSPECT and AC on the diagnostic performance of myocardial scintigraphy, according to patient's sex, body mass index (BMI) and site of coronary artery disease (CAD). We studied a group of 104 patients who underwent coronary angiography within 1 month before or after the SPECT study. Patients with a BMI > 27 were considered ''overweight''. Attenuation-corrected and standard GSPECT early images were randomly interpreted by three readers blinded to the clinical data. In the whole group, GSPECT and AC showed a diagnostic accuracy of 86.5% (sensitivity 82%, specificity 93%) and 77% (sensitivity 75.4%, specificity 81.4%), respectively (p < 0.05). In women, when anterior ischaemia was matched with CAD, AC failed to show any increase in specificity (AC 63.6% vs GSPECT 63.6%) with evident loss of sensitivity (AC 72.7% vs GSPECT 90.9%). AC significantly improved SPECT specificity in the identification of right CAD in overweight men (AC 100% vs GSPECT 66.7%, p <0.05). AC improved specificity in the evaluation of right CAD in overweight men. In the other evaluable subgroups specificity was not significantly affected while sensitivity was frequently reduced. (orig.)

  17. Using Fractal And Morphological Criteria For Automatic Classification Of Lung Diseases

    Science.gov (United States)

    Vehel, Jacques Levy

    1989-11-01

    Medical Images are difficult to analyze by means of classical image processing tools because they are very complex and irregular. Such shapes are obtained for instance in Nuclear Medecine with the spatial distribution of activity for organs such as lungs, liver, and heart. We have tried to apply two different theories to these signals: - Fractal Geometry deals with the analysis of complex irregular shapes which cannot well be described by the classical Euclidean geometry. - Integral Geometry treats sets globally and allows to introduce robust measures. We have computed three parameters on three kinds of Lung's SPECT images: normal, pulmonary embolism and chronic desease: - The commonly used fractal dimension (FD), that gives a measurement of the irregularity of the 3D shape. - The generalized lacunarity dimension (GLD), defined as the variance of the ratio of the local activity by the mean activity, which is only sensitive to the distribution and the size of gaps in the surface. - The Favard length that gives an approximation of the surface of a 3-D shape. The results show that each slice of the lung, considered as a 3D surface, is fractal and that the fractal dimension is the same for each slice and for the three kind of lungs; as for the lacunarity and Favard length, they are clearly different for normal lungs, pulmonary embolisms and chronic diseases. These results indicate that automatic classification of Lung's SPECT can be achieved, and that a quantitative measurement of the evolution of the disease could be made.

  18. Motor activation SPECT for the neurosurgical diseases. Clinical application

    International Nuclear Information System (INIS)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  19. Motor activation SPECT for the neurosurgical diseases. Clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-08-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  20. Applications of cerebral SPECT

    Energy Technology Data Exchange (ETDEWEB)

    McArthur, C., E-mail: claire.mcarthur@nhs.net [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom); Jampana, R.; Patterson, J.; Hadley, D. [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom)

    2011-07-15

    Single-photon emission computed tomography (SPECT) can provide three-dimensional functional images of the brain following the injection of one of a series of radiopharmaceuticals that crosses the blood-brain barrier and distributes according to cerebral perfusion, neurotransmitter, or cell density. Applications include differentiating between the dementias, evaluating cerebrovascular disease, preoperative localization of epileptogenic foci, diagnosing movement disorders, and evaluation of intracerebral tumours, while also proving a useful research tool. Unlike positronemission tomography (PET), SPECT imaging is widely available and can be performed in any department that has access to a rotating gamma camera. The purpose of this review is to demonstrate the utility of cerebral SPECT and increase awareness of its role in the investigation of neurological and psychiatric disorders.

  1. SPECT/CT imaging in children with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E.

    2011-01-01

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  2. Radiopharmaceuticals for SPECT cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Chernov, V. I., E-mail: chernov@oncology.tomsk.ru; Medvedeva, A. A., E-mail: tickayaAA@oncology.tomsk.ru; Zelchan, R. V., E-mail: r.zelchan@yandex.ru; Sinilkin, I. G., E-mail: sinilkinig@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Stasyuk, E. S.; Larionova, L. A. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Slonimskaya, E. M.; Choynzonov, E. L. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  3. The cerebral SPECT in the psychiatric dysfunctions in severe atopic dermatitis; El SPECT cerebral en los trastornos psiquiatricos de la dermatitis atopica severa

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando, Rodolfo; Lago, Graciela [Centro de Medicina Nuclear del Hospital de Clinicas, Montevideo (Uruguay); Vignale, Raul [Departamento de Dermatologia del Hospital de Clinicas, Montevideo (Uruguay); Fabius, Bettina; Lyford Pike, Alexander [Consultorio Psiquiatrico Dr. Lyford Pike, Facultad de Medicina. Universidad de la Republica, Montevideo (Uruguay)

    2007-01-15

    Introduction: Severe atopic dermatitis (AD) usually has a psychiatric component that may influence the course of the cutaneous symptoms. Functional neuroimaging could evidence brain dysfunctions in this kind of patients. Objective: Evaluate the presence and characteristics of cerebral perfusion changes in severe AD patients using SPECT. Materials and methods: 11 severe AD patients were subjected to clinical psychiatric evaluation and 99mTc-ECD SPECT. Results: 90.3% of the patients presented a generalized anxiety disorder, 63.6% an obsessive compulsive disorder and 63.6% a depression. The 11 patients presented perfusion changes that prevailed at the prefrontal cortex. The alterations were concordant with the patterns described in those patients in which anxiety disorders and depression coexist. Conclusions: We demonstrate the frequent presence of perfusion changes in severe AD patients with psychiatric symptoms (au)

  4. Dynamic study on cerebral perfusion of the pentylenetetrazol kindling cats by SPECT

    International Nuclear Information System (INIS)

    Hou Min; Liu Xingdang; Wang Kaiyan

    2004-01-01

    Objective: To learn the change of cerebral perfusion in the pentylenetetrazol kindling cats during the development of epilepsy. Methods: firstly, we performed 12 basic 99m Tc- ethyl cysteinate dimmer (ECD) SPECT as auto-control before the cats were made into epileptic models. Then, according to seizure level of epileptic model, SPECT was performed when the cats began to seizure in the form of facial tic(level 1), nodding spasm (level 2), limb tonic seizures (level 3) and generalized tonic-clonic seizures(level 4). At the same time, we detected the EEG at each level of seizure in order to contrast with SPECT findings. Results:There is no abnormal SPECT finding of cats before using PTZ. The SPECT at each level of kindling: hyperperfusion in forehead and basal ganglia at level 1; more evident hyperperfusion in forehead at level 2; the hyperperfusion in forehead being weakened and another hyperperfusion appearing in deep parietal lobe at level 3; the hyperperfusion in forehead disappearing and the hyperfusion in deep parietal lobe becoming more obvious and a hypoperfusion beside it appearing at level 4. As the time going on, the hyperperfusion disappeared completely and the hypoperfusion became more and more clear. The SPECT findings are coincided with EEG findings. Conclusion: 1. During the kindling of cats, a regional hyperperfusion appeared in the cats' brain: at the stage of focal seizure, the cerebral perfusion increased in forehead and ganglia; at the stage of generalized seizure, the hyperperfusion region gradually moved from forehead to deep parietal lobe. 2. Once the model animal was completely kindled, there would be a fixed hypoperfusion region instead, which may be the epileptic focus. (authors)

  5. SPECT of the brain: Present and future

    International Nuclear Information System (INIS)

    Fazio, F.; Lenzi, G.L.

    1986-01-01

    In both PET and SPECT, most of the studies and the models have been addressed to two organs: brain and heart. So far, brain has certainly been investigated more. The several comparisons between planar scintigraphy and SPECT, between X-ray TCT and SPECT, and also between PET and SPECT, have tended to consider SPECT a cheap but scarcely useful tool for a nuclear medicine section. Again the authors feel that this is due to the fact that SPECT is really a ''physiological tomography'', with little known about its physiology or how it is measured. Thus the present state of the art of SPECT of the brain is characterized by a collection of data and reports on brain imaging and by a slowly growing basic understanding of the utilized modes. The introduction of a new brain-imaging radiopharmaceutical is immediately signaled by its ''first clinical application'' without parallel studies on the kinetics, the metabolic degradation, and the real suitability of the molecule as a tracer for measurement of regional CBF. Only a few attempts seek to narrow this discussion between clinic and biology, and the authors like to emphasize the need for nuclear medicine people to dedicate more time and effort

  6. 123I-iomazenil brain receptor SPECT in focal epilepsy. In comparison with 99mTc-HMPAO brain SPECT, MRI and Video/EEG monitoring

    International Nuclear Information System (INIS)

    Xu Hao; Wang Tongge; Huang Li; Michael Cordes

    1998-01-01

    Purpose: To evaluate the clinical value of 123 I-Iomazenil brain receptor SPECT in diagnosis of focal epilepsy in comparison with 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Methods 123 I-Iomazenil brain receptor SPECT was performed on 40 patients with focal epilepsy. The results were compared with those obtained by 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Results: In 40 patients, the sensitivity of Video/EEG monitoring for localization of epileptogenic area was 95% (38/40). The sensitivity of 123 I-iomazenil brain receptor SPECT, 99m Tc-HMPAO brain SPECT and MRI for localization of epileptogenic area compared with Video/EEG monitoring ('gold standard') was 65.8%(25/38), 55.3%(21/38) and 47.4%(18/38), respectively. The localization of epileptogenic area with 123 I-Iomazenil brain receptor SPECT was in concordance with Video/EEG monitoring in 20 patients, 99m Tc-HMPAO brain SPECT in 15 patients and MRI in 16 patients, respectively. The sensitivity of 123 I-Iomazenil brain receptor SPECT combined with MRI for localization of epileptogenic area was 84.2%(32/38). Conclusions: 123 I-Iomazenil brain receptor SPECT is a useful method in detecting and localizing epileptogenic area. The combination of 123 I-Iomazenil brain receptor SPECT and MRI has a high sensitivity for detecting epileptogenic area

  7. Clinical evaluation of stress thallium spect in ischemic heart disease

    International Nuclear Information System (INIS)

    Sui, Osamu; Kimura, Nazuna; Soeki; Takeshi; Takeichi, Naoki; Shinohara, Hisanori; Tamura, Yoshiyuki; Fukuda, Nobuo

    1997-01-01

    Thallium SPECT was performed in patients with significant coronary artery stenosis, 67 cases were after maximal exercise and 74 cases were during coronary vasodilation induced by ATP (adenosine triphosphate) infusion. In patients suspected of angina pectoris, the sensitivity, specificity and predictive accuracy for detection of coronary artery disease (CAD) were 88%, 78% and 82% for exercise SPECT, and 100%, 72% and 84% for ATP SPECT studies, respectively. In patients with old myocardial infarction, these were 73%, 100% and 88% for exercise SPECT and 71%, 100% and 81% for ATP SPECT. These were 75%, 49% and 60% for treadmill exercise test in the patient group including both angina and myocardial infarction. For detection of diseased vessels, the diagnostic accuracy for left anterior descending artery and right coronary artery lesions was almost equal for ATP and exercise SPECT study, but ATP SPECT study was more sensitive than exercise SPECT study in detection of left circumflex artery lesions. ATP as well as exercise SPECT studies occasionally gave false positive results in patients with single-vessel disease. ATP as well as exercise SPECT studies underestimated the severity of multi-vessel disease. In general, the results of ATP SPECT imaging were highly concordant with the results of exercise SPECT imaging. ATP stress thallium SPECT imaging provided a safe and highly accurate diagnostic tool for detection of CAD. (author)

  8. Mnemonic activation by SPECT

    International Nuclear Information System (INIS)

    Migneco, O.; Darcourt, J.; Benoit, M; Malandain, G.; Thirion, J.P.; Robert, Ph.; Vidal, R.; Desvignes, Ph.; Benoliel, J.; Ayache, N.; Bussiere, F.

    1997-01-01

    Data of literature show that SPECT is able to detect cerebral activations induced by sensory-motor stimuli. The facts are not clearly established in what concerns the cognitive activations the amplitude of which is lower. We have studied an activation paradigm such as the Grober and Bruschke test which implies the long term explicit memory. It comprises a visual presentation of words followed by their indexed recall. By using a two-day protocol, 2 SPECTs were achieved in 4 healthy right-handed voluntaries as follows: one of activation (A) and one of control (B). The fifth subject benefited by a SPECT B and of an MRI. The injection for the examination A has been done during the indexed recall stage and for the examination B at the moment when the patient repeated several times the same 3 words. The SPECT data were collected 1 hour after the injection of 370 MBq of ECD making use of a 3-head camera equipped with UHR fan collimators and ending by a LMH on the reconstructed images of 8 mm. The MRI has been achieved by means of a Signa 1.5 Tesla magnet. The SPECT A and B of the subjects 1 to 4 were matched elastically to that of the subject 5 and that of the subject 5 was rigidly matched on its MRI. In this way the individual activation cards of the 4 subjects could be averaged and superimposed on the MRI of the 5. subject. One observes an internal temporal activation (maximal activation of left tonsil, +25% and right uncus, +23%) and a right cingulum activation (maximal activation, +25%), in agreement with the neuro-physiological data. The elastic matching makes possible the inter-subject averaging, what increases the signal-to-noise ratio of activation. The inter-modality rigid matching facilitates the anatomical localisation of the activation site. With these adapted tools, the cognitive activation is thus possible by SPECT and opens perspectives for early diagnosis of neurological troubles, namely of Alzheimer's disease

  9. SPECT quantification of regional radionuclide distributions

    International Nuclear Information System (INIS)

    Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.

    1986-01-01

    SPECT quantification of regional radionuclide activities within the human body is affected by several physical and instrumental factors including attenuation of photons within the patient, Compton scattered events, the system's finite spatial resolution and object size, finite number of detected events, partial volume effects, the radiopharmaceutical biokinetics, and patient and/or organ motion. Furthermore, other instrumentation factors such as calibration of the center-of-rotation, sampling, and detector nonuniformities will affect the SPECT measurement process. These factors are described, together with examples of compensation methods that are currently available for improving SPECT quantification. SPECT offers the potential to improve in vivo estimates of absorbed dose, provided the acquisition, reconstruction, and compensation procedures are adequately implemented and utilized. 53 references, 2 figures

  10. Radionuclide cisternography: SPECT and 3D-rendering. Radionuklidzisternographie: SPECT- und 3D-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H; Huber, G; Piepgras, U [Universitaet des Saarlandes, Homburg/Saar (Germany, F.R.). Abt. fuer Neuroradiologie; Hierholzer, J [Freie Univ. Berlin (Germany, F.R.). Strahlenklinik und Poliklinik; Cordes, M [British Columbia Univ., Vancouver, BC (Canada). Belzberg Lab. of Neuroscience

    1991-10-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of {sup 111}In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.).

  11. Design of common software for quality control of SPECT

    International Nuclear Information System (INIS)

    Li Xiaohua; Gao Ruzhen; Chen Shengzu

    1993-01-01

    The goal of this study is to design a common testing system for SPECT quality control according to NEMA standard. Using the system, the performances of different types of SPECT can be tested, so that the acceptance testing, performance comparing and routine quality control for SPECT can be normalized. The system was based on IBM PC series of microcomputer. Testing data are acquired from various types of SPECT, then transferred into IBM PC through interface and tested with an unique testing program. Two parts were included: interface and SPECT testing program. It emphatically studied the managing program of RS232 interface, designing skills and the mathematic patterns of SPECT testing program. The system which was composed of 11 subroutines can be used to measure the performances for both gamma camera and SPECT. The system was tested on OMEGA 500/MCS 560 SPECT and the results showed that it is effective, accurate and easy to use

  12. SPECT and PET imaging in epilepsy

    International Nuclear Information System (INIS)

    Semah, F.

    2007-01-01

    Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy. (authors)

  13. Brain spect imaging

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Hill, T.C.; Holman, B.L.

    1989-01-01

    This paper discusses how the rapid development of single-photon radiopharmaceuticals has given new life to tomographic brain imaging in nuclear medicine. Further developments in radiopharmaceuticals and refinements in neuro-SPECT (single-photon emission computed tomography) instrumentation should help to reinstate brain scintigraphy as an important part of neurologic diagnosis. SPECT of the brain evolved from experimentation using prototype instrumentation during the early 1960s. Although tomographic studies provided superior diagnostic accuracy when compared to planar techniques, the arrival of X-ray CT of the head resulted in the rapid demise of technetium brain imaging

  14. Inter-observer variation of diagnosis of Alzheimer's disease by SPECT

    International Nuclear Information System (INIS)

    Oshima, Motoo; Machida, Kikuo; Koizumi, Kiyoshi

    2001-01-01

    SPECT shows characteristic distribution in Alzheimer's disease. The purpose of this study is to define inter-observer variations in the diagnosis of Alzheimer's disease. Fifty-seven patients, included 19 Alzheimer's disease were collected from four institutions. Five-graded score was used to interprete SPECT in 18 regions. Ten nuclear medicine physicians interpreted SPECT referred with MMSE and clinical information. Among 57 cases 19 Alzheimer's disease were selected in this study. Statistics were performed between SPECT score and MMSE score. In conclusion, inter-observer variation is present in SPECT interpretation. There was a good correlation SPECT and MMSE with proper brain SPECT physicians. They are superior to in the interpretation not only resident, but other specialists. Education in the interpretation of brain SPECT looks important. (author)

  15. Evaluation of usefulness of bone SPECT for lumbar spondylolysis

    International Nuclear Information System (INIS)

    Watanabe, Osamu; Hashimoto, Manabu; Tomura, Noriaki; Watarai, Jiro

    2002-01-01

    The purpose of this study was to evaluate the usefulness of 99m Tc-MDP SPECT (bone SPECT) for lumbar spondylolysis. We analyzed 11 cases with 17 lesions. All cases were compared using plain radiography, computed tomography (CT), planar bone scintigraphy (PBS), and bone SPECT. Four lesions that showed a wide defect on CT were negative on bone SPECT and may have been chronic lesions. Thirteen lesions that were positive on bone SPECT were narrow or showed no defect on CT and may have been early lesions. Two cases showed no defect on CT but were positive on bone SPECT, and one of them progressed to bilateral spondylolysis after one year. This may have been a very early lesion. Thus bone SPECT is useful for the diagnosis of lumbar spondylolysis, especially in its early stage. (author)

  16. Evaluation of usefulness of bone SPECT for lumbar spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Osamu; Hashimoto, Manabu; Tomura, Noriaki; Watarai, Jiro [Akita Univ. (Japan). School of Medicine

    2002-07-01

    The purpose of this study was to evaluate the usefulness of {sup 99m}Tc-MDP SPECT (bone SPECT) for lumbar spondylolysis. We analyzed 11 cases with 17 lesions. All cases were compared using plain radiography, computed tomography (CT), planar bone scintigraphy (PBS), and bone SPECT. Four lesions that showed a wide defect on CT were negative on bone SPECT and may have been chronic lesions. Thirteen lesions that were positive on bone SPECT were narrow or showed no defect on CT and may have been early lesions. Two cases showed no defect on CT but were positive on bone SPECT, and one of them progressed to bilateral spondylolysis after one year. This may have been a very early lesion. Thus bone SPECT is useful for the diagnosis of lumbar spondylolysis, especially in its early stage. (author)

  17. SPECT assay of radiolabeled monoclonal antibodies

    International Nuclear Information System (INIS)

    Jaszczak, R.J.

    1992-02-01

    The long-term goal of this research project is to develop methods to improve the utility of single photon emission computed tomography (SPECI) to quantify the biodistribution of monoclonal antibodies (MoAbs) labeled with clinically relevant radionuclides ( 123 I, 131 I, and 111 In) and with another radionuclide, 211 At, recently used in therapy. We describe here our progress in developing quantitative SPECT methodology for 111 In and 123 I. We have focused our recent research thrusts on the following aspects of SPECT: (1) The development of improved SPECT hardware, such as improved acquisition geometries. (2) The development of better reconstruction methods that provide accurate compensation for the physical factors that affect SPECT quantification. (3) The application of carefully designed simulations and experiments to validate our hardware and software approaches

  18. Cerebral SPECT, a new diagnostic marker in depression

    International Nuclear Information System (INIS)

    Galli, Enrique

    2001-01-01

    Over the past twenty years the functional brain imagenology has improved greatly. Today the diagnostic, prognostic and therapeutic response are possible in psychiatry and neurology. The functional denomination in psychiatry has been known for more than a 100 years and it can be evident in the brain images. The relation between the blood brain flux and the brain can be seen as pictures in the Brain SPECT as hyper and hypo function areas. To carry out SPECT a venous injection of Tc-99m Technetium and (HMPAO) or (ECD) is applied in the arm. The images correspond to a period of two minutes after injection. The exam can be done until six hours after the brain fixation. The study is carried out in conditions, with the patient in repose, relaxed and without medication. The final result is an brain in colors. The yellow color gives us 95% of decrease and white color 95% of increase of the brain function. The red color gives a normal perfusion. The object of the study is to find that the Brain SPECT could be used as a new diagnostic marker of depression. The sample was 73 outpatients with major depression Our diagnostic marker is the prefrontal cortex ventral hypoperfusion (orbit frontal) in almost 100% of the patients and only 32% dorsal hypoperfusion (executive area), unlike most authors (Au)

  19. Importance of SPECT/CT for knee and hip joint prostheses; Stellenwert der SPECT/CT bei Knie- und Hueftgelenkprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, K.; Steurer-Dober, I.; Huellner, M.W.; Veit-Haibach, P.; Allgayer, B. [Luzerner Kantonsspital (Switzerland). Institut fuer Nuklearmedizin und Roentgendiagnostik

    2012-07-15

    Complications, such as loosening or infections are common problems after hip or knee arthroplasty. If conventional X-rays are equivocal bone scintigraphy is the classical second-line imaging modality. Single photon emission computed tomography/computed tomography (SPECT/CT) offers metabolic and morphologic information in one imaging step and is becoming increasingly more available in larger hospitals. The SPECT/CT procedure is a promising method and is increasingly being used in daily routine to evaluate joint arthroplasty. The additional benefit compared with classical conventional bone scintigraphy has to be evaluated in further prospective studies. In our hospital SPECT/CT regularly gives important additional information regarding prosthetic joint complications. SPECT/CT is increasingly being used as the second step imaging standard modality if conventional X-rays are equivocal. (orig.) [German] Komplikationen wie Lockerung und Infekt stellen ein haeufiges Problem nach Hueft- und Kniegelenkprothesen dar. Wenn die konventionelle Roentgenaufnahme nicht zum Ziel fuehrt, ist die klassische konventionelle Skelettszintigraphie die am haeufigsten verwendete ''Second-line''-Bildgebung. Die ''single photon emission computed tomography''/CT (SPECT/CT) bietet metabolische und morphologische Informationen bzgl. Prothesenkomplikationen in einem Untersuchungsgang und ist zunehmend in groesseren Kliniken verfuegbar. Die SPECT/CT ist eine viel versprechende Methode und wird im klinischen Alltag bei der Evaluation von Gelenkprothesen zunehmend eingesetzt. Es sind noch mehr prospektive Studien noetig, um die Leistungsfaehigkeit und den Zusatznutzen gegenueber der klassischen Szintigraphie zu evaluieren. In unserer Klinik wird die Knochenszintigraphie bei der Abklaerung von Prothesenkomplikationen zumeist mit einer SPECT/CT kombiniert und liefert regelmaessig wichtige Zusatzinformationen. Die SPECT/CT entwickelt sich zunehmend zum Standard

  20. Clinical use of digital retrospective image fusion of CT, MRI, FDG-PET and SPECT - fields of indications and results; Klinischer Einsatz der digitalen retrospektiven Bildfusion von CT, MRT, FDG-PET und SPECT - Anwendungsgebiete und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Lemke, A.J.; Niehues, S.M.; Amthauer, H.; Felix, R. [Campus Virchow-Klinikum, Klinik fuer Strahlenheilkunde, Charite, Universitaetsmedizin Berlin (Germany); Rohlfing, T. [Dept. of Neurosurgery, Stanford Univ. (United States); Hosten, N. [Inst. fuer Diagnostische Radiologie, Ernst-Moritz-Arndt-Univ. Greifswald (Germany)

    2004-12-01

    Purpose: To evaluate the feasibility and the clinical benefits of retrospective digital image fusion (PET, SPECT, CT and MRI). Materials and methods: In a prospective study, a total of 273 image fusions were performed and evaluated. The underlying image acquisitions (CT, MRI, SPECT and PET) were performed in a way appropriate for the respective clinical question and anatomical region. Image fusion was executed with a software program developed during this study. The results of the image fusion procedure were evaluated in terms of technical feasibility, clinical objective, and therapeutic impact. Results: The most frequent combinations of modalities were CT/PET (n = 156) and MRI/PET (n = 59), followed by MRI/SPECT (n = 28), CT/SPECT (n = 22) and CT/MRI (n = 8). The clinical questions included following regions (more than one region per case possible): neurocranium (n = 42), neck (n = 13), lung and mediastinum (n = 24), abdomen (n = 181), and pelvis (n = 65). In 92.6% of all cases (n = 253), image fusion was technically successful. Image fusion was able to improve sensitivity and specificity of the single modality, or to add important diagnostic information. Image fusion was problematic in cases of different body positions between the two imaging modalities or different positions of mobile organs. In 37.9% of the cases, image fusion added clinically relevant information compared to the single modality. Conclusion: For clinical questions concerning liver, pancreas, rectum, neck, or neurocranium, image fusion is a reliable method suitable for routine clinical application. Organ motion still limits its feasibility and routine use in other areas (e.g., thorax). (orig.)

  1. Functional image-based radiotherapy planning for non-small cell lung cancer: A simulation study

    International Nuclear Information System (INIS)

    Bates, Emma L.; Bragg, Christopher M.; Wild, Jim M.; Hatton, Matthew Q.F.; Ireland, Rob H.

    2009-01-01

    Background and purpose: To investigate the incorporation of data from single-photon emission computed tomography (SPECT) or hyperpolarized helium-3 magnetic resonance imaging ( 3 He-MRI) into intensity-modulated radiotherapy (IMRT) planning for non-small cell lung cancer (NSCLC). Material and methods: Seven scenarios were simulated that represent cases of NSCLC with significant functional lung defects. Two independent IMRT plans were produced for each scenario; one to minimise total lung volume receiving ≥20 Gy (V 20 ), and the other to minimise only the functional lung volume receiving ≥20 Gy (FV 20 ). Dose-volume characteristics and a plan quality index related to planning target volume coverage by the 95% isodose (V PTV95 /FV 20 ) were compared between anatomical and functional plans using the Wilcoxon signed ranks test. Results: Compared to anatomical IMRT plans, functional planning reduced FV 20 (median 2.7%, range 0.6-3.5%, p = 0.02), and total lung V 20 (median 1.5%, 0.5-2.7%, p = 0.02), with a small reduction in mean functional lung dose (median 0.4 Gy, 0-0.7 Gy, p = 0.03). There were no significant differences in target volume coverage or organ-at-risk doses. Plan quality index was improved for functional plans (median increase 1.4, range 0-11.8, p = 0.02). Conclusions: Statistically significant reductions in FV 20 , V 20 and mean functional lung dose are possible when IMRT planning is supplemented by functional information derived from SPECT or 3 He-MRI.

  2. Brain imaging during seizure: ictal brain SPECT

    International Nuclear Information System (INIS)

    Kottamasu, Sambasiva Rao

    1997-01-01

    The role of single photon computed tomography (SPECT) in presurgical localization of medically intractable complex partial epilepsy (CPE) in children is reviewed. 99m Technetium neurolite, a newer lipophylic agent with a high first pass brain extraction and little or no redistribution is injected during a seizure, while the child is monitored with a video recording and continuous EEG and SPECT imaging is performed in the next 1-3 hours with the images representing regional cerebral profusion at the time of injection. On SPECT studies performed with radiopharmaceutical injected during a seizure, ictal focus is generally hypervascular. Other findings on ictal brain SPECT include hypoperfusion of adjacent cerebral cortex and white matter, hyperperfusion of contralateral motor cortex, hyperperfusion of ipsilateral basal ganglia and thalamus, brain stem and contralateral cerebellum. Ictal brain SPECT is non-invasive, cost effective and highly sensitive for localization of epileptic focus in patients with intractable CPE. (author)

  3. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  4. SU-E-I-80: Quantification of Respiratory and Cardiac Motion Effect in SPECT Acquisitions Using Anthropomorphic Models: A Monte Carlo Simulation Study

    Energy Technology Data Exchange (ETDEWEB)

    Papadimitroulas, P; Kostou, T; Kagadis, G [University of Patras, Rion, Ahaia (Greece); Loudos, G [Technological Educational Institute of Athens, Egaleo, Attika (Greece)

    2015-06-15

    Purpose: The purpose of the present study was to quantify, evaluate the impact of cardiac and respiratory motion on clinical nuclear imaging protocols. Common SPECT and scintigraphic scans are studied using Monte Carlo (MC) simulations, comparing the resulted images with and without motion. Methods: Realistic simulations were executed using the GATE toolkit and the XCAT anthropomorphic phantom as a reference model for human anatomy. Three different radiopharmaceuticals based on 99mTc were studied, namely 99mTc-MDP, 99mTc—N—DBODC and 99mTc—DTPA-aerosol for bone, myocardium and lung scanning respectively. The resolution of the phantom was set to 3.5 mm{sup 3}. The impact of the motion on spatial resolution was quantified using a sphere with 3.5 mm diameter and 10 separate time frames, in the ECAM modeled SPECT scanner. Finally, respiratory motion impact on resolution and imaging of lung lesions was investigated. The MLEM algorithm was used for data reconstruction, while the literature derived biodistributions of the pharmaceuticals were used as activity maps in the simulations. Results: FWHM was extracted for a static and a moving sphere which was ∼23 cm away from the entrance of the SPECT head. The difference in the FWHM was 20% between the two simulations. Profiles in thorax were compared in the case of bone scintigraphy, showing displacement and blurring of the bones when respiratory motion was inserted in the simulation. Large discrepancies were noticed in the case of myocardium imaging when cardiac motion was incorporated during the SPECT acquisition. Finally the borders of the lungs are blurred when respiratory motion is included resulting to a dislocation of ∼2.5 cm. Conclusion: As we move to individualized imaging and therapy procedures, quantitative and qualitative imaging is of high importance in nuclear diagnosis. MC simulations combined with anthropomorphic digital phantoms can provide an accurate tool for applications like motion correction

  5. SPECT/CT Fusion in the Diagnosis of Hyperparathyroidism

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Tamura, Akihisa; Okazaki, Hajime; Kurose, Taichi; Kobayashi, Masayuki; Kuraoka, Masatsugu

    2015-01-01

    In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/ computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) were imaged 15 and 120 minutes after the intravenous injection of technetium99m-methoxyisobutylisonitrile ( 99m Tc-MIBI). All patients underwent surgery and 5 parathyroid adenomas and 10 hyperplastic glands were detected. Pathologic findings were correlated with imaging results. The SPECT/CT fusion images were able to detect all parathyroid adenomas even with the greatest axial diameter of 0.6 cm. Planar scintigraphy and SPECT imaging could not detect parathyroid adenomas with an axial diameter of 1.0 to 1.2 cm. Four out of 10 (40%) hyperplastic parathyroid glands were diagnosed, using planar and SPECT imaging and 5 out of 10 (50%) hyperplastic parathyroid glands were localized, using SPECT/CT fusion images. SPECT/CT fusion imaging is a more useful tool for localization of parathyroid lesions, particularly parathyroid adenomas, in comparison with planar and or SPECT imaging

  6. Dopamine transporter imaging with [123I]FP-CIT SPECT: potential effects of drugs

    International Nuclear Information System (INIS)

    Booij, Jan; Kemp, Paul

    2008-01-01

    [ 123 I]N-ω-fluoropropyl-2β-carbomethoxy-3β-{4-iodophenyl}nortropane ([ 123 I]FP-CIT) single photon emission computed tomography (SPECT) is a frequently and routinely used technique to detect or exclude dopaminergic degeneration by imaging the dopamine transporter (DAT) in parkinsonian and demented patients. This technique is also used in scientific studies in humans, as well as in preclinical studies to assess the availability of DAT binding in the striatum. In routine clinical studies, but also in scientific studies, patients are frequently on medication and sometimes even use drugs of abuse. Moreover, in preclinical studies, animals will be anesthetized. Prescribed drugs, drugs of abuse, and anesthetics may influence the visual interpretation and/or quantification of [ 123 I]FP-CIT SPECT scans. Here, we discuss the basic principle of how drugs and anesthetics might influence the visual interpretation and/or quantification of [ 123 I]FP-CIT SPECT scans. We also review drugs which are likely to have a significant influence on the visual interpretation and/or quantification of [ 123 I]FP-CIT SPECT scans. Additionally, we discuss the evidence as to whether frequently prescribed drugs in parkinsonian and demented patients may have an influence on the visual interpretation and/or quantification of [ 123 I]FP-CIT SPECT scans. Finally, we discuss our recommendations as to which drugs should be ideally withdrawn before performing a [ 123 I]FP-CIT SPECT scan for routine clinical purposes. The decision to withdraw any medication must always be made by the specialist in charge of the patient's care and taking into account the pros and cons of doing so. (orig.)

  7. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  8. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  9. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  10. PET and SPECT in psychiatry

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Otte, Andreas; Vries, Erik F.J. de; Waarde, Aren van

    2014-01-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  11. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  12. Contralateral thalamic hypoperfusion on brain perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun; Yoo, Kyung Moo; Yum, Ha Yong

    2000-01-01

    Brain perfusion single photon emission computed tomography (SPECT) is useful for the localization of cerebrovascular lesion and sometimes reveals more definite lesion than radiologic imaging modality such as CT or MRI does. The purpose of this study was to evaluate the diagnostic usefulness of brain perfusion SPECT in patients with hemisensory impairment. Thirteen consecutive patients (M:F= 8:5, mean age = 48) who has hemisensory impairment were included. Brain perfusion SPECT was performed after intravenous injection of 1110 MBq of Tc-99m ECD. The images were obtained using a dual-head gamma camera with ultra-high resolution collimator. Semiquantitative analysis was performed after placing multiple ROIs on cerebral cortex, basal ganglia, thalamus and cerebellum. There were 10 patients with left hemisensory impairment and 3 patients with right-sided symptom. Only 2 patients revealed abnormal signal change in the thalamus on MRI. But brain perfusion SPECT showed decreased perfusion in the thalamus in 9 patients. Six patients among 10 patients with left hemisensory impairment revealed decreased perfusion in the contralateral thalamus on brain SPECT. The other 4 patients revealed no abnormality. Two patients among 3 patients with right hemisensory impairment also showed decreased perfusion in the contralateral thalamus on brain SPECT. One patients with right hemisensory impairment showed ipsilateral perfusion decrease. Two patients who had follow-up brain perfusion SEPCT after treatment revealed normalization of perfusion in the thalamus. Brain perfusion SPECT might be a useful tool in diagnosing patients with hemisensory impairment

  13. Two quantitative methods for assessment of [Tc-99m]-MAA in the lung in the treatment of liver metastases: a case study

    International Nuclear Information System (INIS)

    Willowson, Kathy P.; Bailey, Dale L.; Baldock, Clive

    2009-01-01

    Full text: Objective: The use of Y-90 microspheres to treat metastatic liver cancer is becoming widely utilized. Despite the fact that the microspheres are delivered directly to the liver, some activity may bypass the liver capillaries and be shunted to the lungs. To evaluate the percentage of pulmonary breakthrough, a pre-therapy test is performed using Tc- 9 9 m labeled spheres. The aim of this project was to compare two quantitative methods for assessing lung uptake, and consider the possibility of organ specific quantification. Method: A previously validated method for achieving CT-based quantitative SPECTI was compared to a simple planar approach. A 44 year old man suffering from metastatic liver sarcoma was referred to the clinic for pre-therapy evaluation. After injection of Tc- 9 9 m labeled microspheres and routine imaging, a SPECT/CT was acquired and specific organ uptake values calculated. A further calibrated injection of [Tc- 9 9 m ]-MAA was then given as a simplified alternative to quantify lung uptake by comparing pre and post counts. Results: The quantitative SPECT/CT method correctly accounted for all injected activity and found 80% of the dose was retained in the liver and 4% in the lungs. The planar method found -4% of the dose in the lungs. Conclusion: The quantitative technique we have developed allows for accurate calculation of organ specific uptake, which has important implications for treatment. The additional MAA injection offers a simplified but accurate method to quantify lung uptake. I. K Willow son, D.L Bailey and C Baldock (2008) Quantitative SPECT reconstructions using CT-derived corrections Phys Med Bioi 53:3099-3112.

  14. 99mTc-HMPAO SPECT of the brain in mild to moderate traumatic brain injury patients: compared with CT--a prospective study.

    Science.gov (United States)

    Nedd, K; Sfakianakis, G; Ganz, W; Uricchio, B; Vernberg, D; Villanueva, P; Jabir, A M; Bartlett, J; Keena, J

    1993-01-01

    Single photon emission computed tomography (SPECT) with Technetium-99m hexamethyl propylenamine oxime (Tc-99m-HMPAO) was used in 20 patients with mild to moderate traumatic brain injury (TBI) to evaluate the effects of brain trauma on regional cerebral blood flow (rCBF). SPECT scan was compared with CT scan in 16 patients. SPECT showed intraparenchymal differences in rCBF more often than lesions diagnosed with CT scans (87.5% vs. 37.5%). In five of six patients with lesions in both modalities, the area of involvement was relatively larger on SPECT scans than on CT scans. Contrecoup changes were seen in five patients on SPECT alone, two patients with CT alone and one patient had contrecoup lesions on CT and SPECT. Of the eight patients (50%) with skull fractures, seven (43.7%) had rCBF findings on SPECT scan and five (31.3%) demonstrated decrease in rCBF in brain underlying the fracture. All these patients with fractures had normal brain on CT scans. Conversely, extra-axial lesions and fractures evident on CT did not visualize on SPECT, but SPECT demonstrated associated changes in rCBF. Although there is still lack of clinical and pathological correlation, SPECT appears to be a promising method for a more sensitive evaluation of axial lesions in patients with mild to moderate TBI.

  15. Clinical applications of SPECT/CT: advantages and limitations

    International Nuclear Information System (INIS)

    Rigo, P.

    2006-01-01

    The application of hybrid SPECT cameras in Nuclear Medicine follows the revolutionary introduction of PET/CT. This review focuses on the advantages and limitations of SPECT/CT in its various clinical indications. It appears that SPECT/CT will be a clear factor of progress for Nuclear Medicine. (author)

  16. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  17. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  18. Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging

    Science.gov (United States)

    Konik, Arda Bekir

    ) digital phantoms. In addition, PET projection files for different sizes of MOBY phantoms were reconstructed in 6 different conditions including attenuation and scatter corrections. Selected regions were analyzed for these different reconstruction conditions and object sizes. Finally, real mouse data from the real version of the same small animal PET scanner we modeled in our simulations were analyzed for similar reconstruction conditions. Both our IDL and GATE simulations showed that, for small animal PET and SPECT, even the smallest size objects (˜2 cm diameter) showed ˜15% error when both attenuation and scatter were not corrected. However, a simple attenuation correction using a uniform attenuation map and object boundary obtained from emission data significantly reduces this error in non-lung regions (˜1% for smallest size and ˜6% for largest size). In lungs, emissions values were overestimated when only attenuation correction was performed. In addition, we did not observe any significant improvement between the uses of uniform or actual attenuation map (e.g., only ˜0.5% for largest size in PET studies). The scatter correction was not significant for smaller size objects, but became increasingly important for larger sizes objects. These results suggest that for all mouse sizes and most rat sizes, uniform attenuation correction can be performed using emission data only. For smaller sizes up to ˜ 4 cm, scatter correction is not required even in lung regions. For larger sizes if accurate quantization needed, additional transmission scan may be required to estimate an accurate attenuation map for both attenuation and scatter corrections.

  19. Clinical utility of SPECT neuroimaging in the diagnosis and treatment of traumatic brain injury: a systematic review.

    Directory of Open Access Journals (Sweden)

    Cyrus A Raji

    Full Text Available PURPOSE: This systematic review evaluated the clinical utility of single photon emission computed tomography (SPECT in traumatic brain injury (TBI. METHODS: After defining a PICO Statement (Population, Intervention, Comparison and Outcome Statement, PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria were applied to identify 1600 articles. After screening, 374 articles were eligible for review. Inclusion for review was focus on SPECT in the setting of mild, moderate, or severe TBI with cerebral lobar specificity of SPECT findings. Other inclusion criteria were comparison modalities in the same subjects and articles in English. Foreign language articles, SPECT studies that did not include comparison modalities, and case reports were not included for review. RESULTS: We identified 19 longitudinal and 52 cross-sectional studies meeting inclusion criteria. Three longitudinal studies examined diagnostic predictive value. The first showed positive predictive value increases from initial SPECT scan shortly after trauma to one year follow up scans, from 59% to 95%. Subsequent work replicated these results in a larger cohort. Longitudinal and cross sectional studies demonstrated SPECT lesion localization not detected by CT or MRI. The most commonly abnormal regions revealed by SPECT in cross-sectional studies were frontal (94% and temporal (77% lobes. SPECT was found to outperform both CT and MRI in both acute and chronic imaging of TBI, particularly mild TBI. It was also found to have a near 100% negative predictive value. CONCLUSIONS: This review demonstrates Level IIA evidence (at least one non-randomized controlled trial for the value of SPECT in TBI. Given its advantages over CT and MRI in the detection of mild TBI in numerous studies of adequate quality, and given its excellent negative predictive value, it may be an important second test in settings where CT or MRI are negative after a closed head injury with post

  20. Clinical utility of SPECT neuroimaging in the diagnosis and treatment of traumatic brain injury: a systematic review.

    Science.gov (United States)

    Raji, Cyrus A; Tarzwell, Robert; Pavel, Dan; Schneider, Howard; Uszler, Michael; Thornton, John; van Lierop, Muriel; Cohen, Phil; Amen, Daniel G; Henderson, Theodore

    2014-01-01

    This systematic review evaluated the clinical utility of single photon emission computed tomography (SPECT) in traumatic brain injury (TBI). After defining a PICO Statement (Population, Intervention, Comparison and Outcome Statement), PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) criteria were applied to identify 1600 articles. After screening, 374 articles were eligible for review. Inclusion for review was focus on SPECT in the setting of mild, moderate, or severe TBI with cerebral lobar specificity of SPECT findings. Other inclusion criteria were comparison modalities in the same subjects and articles in English. Foreign language articles, SPECT studies that did not include comparison modalities, and case reports were not included for review. We identified 19 longitudinal and 52 cross-sectional studies meeting inclusion criteria. Three longitudinal studies examined diagnostic predictive value. The first showed positive predictive value increases from initial SPECT scan shortly after trauma to one year follow up scans, from 59% to 95%. Subsequent work replicated these results in a larger cohort. Longitudinal and cross sectional studies demonstrated SPECT lesion localization not detected by CT or MRI. The most commonly abnormal regions revealed by SPECT in cross-sectional studies were frontal (94%) and temporal (77%) lobes. SPECT was found to outperform both CT and MRI in both acute and chronic imaging of TBI, particularly mild TBI. It was also found to have a near 100% negative predictive value. This review demonstrates Level IIA evidence (at least one non-randomized controlled trial) for the value of SPECT in TBI. Given its advantages over CT and MRI in the detection of mild TBI in numerous studies of adequate quality, and given its excellent negative predictive value, it may be an important second test in settings where CT or MRI are negative after a closed head injury with post-injury neurological or psychiatric symptoms.

  1. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

    Science.gov (United States)

    Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo

    2015-06-01

    A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR

  2. SPECT imaging with resolution recovery

    International Nuclear Information System (INIS)

    Bronnikov, A. V.

    2011-01-01

    Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

  3. Rapid gated Thallium-201 perfusion SPECT - clinically feasible?

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.; Wilkinson, D.; Abatti, D.

    1998-01-01

    Full text: Standard dose energy window optimised Thallium-201 (Tl-201) SPECT has about half the counts of a standard dose from Technetium-99m Sestamibi (Tc99m-Mibi) gated perfusion SPECT. This study investigates the clinical feasibility of rapid energy window optimised Tl-201 gated perfusion SPECT (gated-TI) and compares quantitative left ventricular ejection fraction (LVEF) and visually assessed image quality for wall motion and thickening to analogous values obtained from Tc99m-Mibi gated perfusion SPECT (gated - mibi). Methods: We studied 60 patients with a rest gated Tl-201 SPECT (100 MBq, 77KeV peak, 34% window, 20 sec/projection) followed by a post stress gated Sestamibi SPECT (1GBq, 140KeV, 20% window, 20 sec/projection) separate dual isotope protocol. LVEF quantitation was performed using commercially available software (SPECTEF, General Electric). Visual grading of image quality for wall thickening and motion was performed using a three-point scale (excellent, good and poor). Results: LVEF for gated Tl-201 SPECT was 59.6 ± 12.0% (Mean ± SD). LVEF for gated Sestamibi SPECT was 60.4 ±11.4% (Mean ± SD). These were not significantly different (P=0.27, T-Test). There was good correlation (r=0.9) between gated-TI and gated-mibi LVEF values. The quality of gated-Tl images was ranked as excellent, good and poor in 12, 50 and 38% of the patients respectively. Image quality was better in gated-mibi SPECT, with ratings of 12, 62 and 26% respectively. Conclusion: Rapid gated Thallium-201 acquisition with energy window optimisation can be effectively performed on majority of patients and offers the opportunity to assess not only myocardial perfusion and function, as with Technetium based agents, but also viability using a single day one isotope protocol

  4. Role of SPECT imaging in symptomatic posterior element lumbar stress injuries

    Directory of Open Access Journals (Sweden)

    Debnath U

    2005-01-01

    Full Text Available Background : Diagnosis of stress injuries of spine is very difficult with conventional radiography. Methods : In a observational study, 132 subjects were recruited (between 8 and 38 years of age, who had lumbar spondylolysis or posterior element stress injuries. All these patients underwent clinical examination followed by plain X-rays, planar bone scintigraphy and SPECT (single photon emission computerised tomography. SPECT scans can identify the posterior element lumbar stress injuries earlier than other imaging modalities. As the lesions evolve and the completed spondylolysis becomes chronic, the SPECT scans tend to revert to normal even though healing of the defect has not occurred. The aim of the study was to determine the time lag after which SPECT imaging tends to be negative. We divided the patients into two groups, one SPECT positive group and the other SPECT negative group. Pre treatment background variables such as age, gender, back pain in extension or flexion, sporting activities, time of onset of symptoms, Oswestry Disability Index (ODI were used in a univariate logistic regression model to find the strong predictors of positive SPECT imaging results. Determinants of positivity versus negativity of SPECT were identified by discriminant analysis using multivariate logistic regression. Results : Seventy nine patients had positive SPECT scans whereas 53 patients had negative SPECT scans. Bilateral increased uptake was more common than unilateral uptake. Increased uptake at the L5 lumbar spine was more common (70% in SPECT positive group. Low back pain in extension was significantly more common in SPECT positive subjects. Active sporting individuals had higher probability of having a positive SPECT scan. The mean time lag from the onset of low back pain to SPECT imaging was 7 months in SPECT positive group and 25 months in the SPECT negative group. Multivariate analysis predicted that there is a significant difference in positivity of

  5. Identification of Ambiguous Activities in Radionuclide Cisternography Using SPECT/CT: Aspirated and Ingested CSF Rhinorrhea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yun; Kim, Jae Seung [Univ. of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2014-03-15

    A 2 year-old little girl underwent Tc-99m diethylenthriamine pentaacetic acid (DTPA) radionuclide cisternography to evaluate CSF rhinorrhea (Fig. 1). Cisternography clearly showed consecutive tracer activity in the nasal cavity and nasal tip, reflecting cerebrospinal fluid (CSF) leakage. However, several unexpected activities appeared on the bilateral mid- and unilateral lower thorax on delayed images, respectively. We performed additional SPECT/CT to delineate the CSF leakage tract and identify the unexpected activities. Through SPECT/CT, we could confirm that the mid-thoracic activity was in the lung parenchyma, while the lower thoracic activity was in the stomach. Thus, we speculated that these unexpected activities were the result of aspirated and ingested CSF rhinorrhea. CSF rhinorrhea occurs when there is a fistula between the dura mater and the skull base and discharge of CSF from the nose. A spinal fluid leak from the intracranial space to the nasal respiratory tract is potentially very serious because of the risk of an ascending infection that could produce fulminant meningitis. Therefore, identification of the fistulous tract is helpful for patient management. Radionuclide cisternography is an important imaging modality to detect the site of leakage in patients with CSF rhinorrhea. The combination of radionuclide cistenography and SPECT/CT has led to a major improvement in the diagnostic accuracy for localization of CSF leakage. This case also shows an important role for SPECT/CT fusion imaging in radionuclide cisternography not only for localizing the primary CSF fistula tract, but also for evaluating ambiguous radiotracer activities in planar imaging; these ultimately turned out to be aspirated and ingested CSF rhinorrhea.

  6. Identification of Ambiguous Activities in Radionuclide Cisternography Using SPECT/CT: Aspirated and Ingested CSF Rhinorrhea

    International Nuclear Information System (INIS)

    Lee, Dong Yun; Kim, Jae Seung

    2014-01-01

    A 2 year-old little girl underwent Tc-99m diethylenthriamine pentaacetic acid (DTPA) radionuclide cisternography to evaluate CSF rhinorrhea (Fig. 1). Cisternography clearly showed consecutive tracer activity in the nasal cavity and nasal tip, reflecting cerebrospinal fluid (CSF) leakage. However, several unexpected activities appeared on the bilateral mid- and unilateral lower thorax on delayed images, respectively. We performed additional SPECT/CT to delineate the CSF leakage tract and identify the unexpected activities. Through SPECT/CT, we could confirm that the mid-thoracic activity was in the lung parenchyma, while the lower thoracic activity was in the stomach. Thus, we speculated that these unexpected activities were the result of aspirated and ingested CSF rhinorrhea. CSF rhinorrhea occurs when there is a fistula between the dura mater and the skull base and discharge of CSF from the nose. A spinal fluid leak from the intracranial space to the nasal respiratory tract is potentially very serious because of the risk of an ascending infection that could produce fulminant meningitis. Therefore, identification of the fistulous tract is helpful for patient management. Radionuclide cisternography is an important imaging modality to detect the site of leakage in patients with CSF rhinorrhea. The combination of radionuclide cistenography and SPECT/CT has led to a major improvement in the diagnostic accuracy for localization of CSF leakage. This case also shows an important role for SPECT/CT fusion imaging in radionuclide cisternography not only for localizing the primary CSF fistula tract, but also for evaluating ambiguous radiotracer activities in planar imaging; these ultimately turned out to be aspirated and ingested CSF rhinorrhea

  7. WE-AB-202-08: Feasibility of Single-Inhalation/Single-Energy Xenon CT for High-Resolution Imaging of Regional Lung Ventilation in Humans

    International Nuclear Information System (INIS)

    Pinkham, D; Schueler, E; Diehn, M; Mittra, E; Loo, B; Maxim, P; Negahdar, M; Yamamoto, T

    2016-01-01

    Purpose: To demonstrate the efficacy of a novel functional lung imaging method that utilizes single-inhalation, single-energy xenon CT (Xe-CT) lung ventilation scans, and to compare it against the current clinical standard, ventilation single-photon emission CT (V-SPECT). Methods: In an IRB-approved clinical study, 14 patients undergoing thoracic radiotherapy received two successive single inhalation, single energy (80keV) CT images of the entire lung using 100% oxygen and a 70%/30% xenon-oxygen mixture. A subset of ten patients also received concurrent SPECT ventilation scans. Anatomic reproducibility between the two scans was achieved using a custom video biofeedback apparatus. The CT images were registered to each other by deformable registration, and a calculated difference image served as surrogate xenon ventilation map. Both lungs were partitioned into twelve sectors, and a sector-wise correlation was performed between the xenon and V-SPECT scans. A linear regression model was developed with forced expiratory volume (FEV) as a predictor and the coefficient of variation (CoV) as the outcome. Results: The ventilation comparison for five of the patients had either moderate to strong Pearson correlation coefficients (0.47 to 0.69, p<0.05). Of these, four also had moderate to strong Spearman correlation coefficients (0.46 to 0.80, p<0.03). The patients with the strongest correlation had clear regional ventilation deficits. The patient comparisons with the weakest correlations had more homogeneous ventilation distributions, and those patients also had diminished lung function as assessed by spirometry. Analysis of the relationship between CoV and FEV yielded a non-significant trend toward negative correlation (Pearson coefficient −0.60, p<0.15). Conclusion: Significant correlations were found between the Xe-CT and V-SPECT ventilation imagery. The results from this small cohort of patients indicate that single inhalation, single energy Xe-CT has the potential to

  8. WE-AB-202-08: Feasibility of Single-Inhalation/Single-Energy Xenon CT for High-Resolution Imaging of Regional Lung Ventilation in Humans

    Energy Technology Data Exchange (ETDEWEB)

    Pinkham, D; Schueler, E; Diehn, M; Mittra, E; Loo, B; Maxim, P [Stanford University School of Medicine, Palo Alto, California (United States); Negahdar, M [IBM Research Center, San Jose, California (United States); Yamamoto, T [University of California Davis Medical Center, Sacramento, CA (United States)

    2016-06-15

    Purpose: To demonstrate the efficacy of a novel functional lung imaging method that utilizes single-inhalation, single-energy xenon CT (Xe-CT) lung ventilation scans, and to compare it against the current clinical standard, ventilation single-photon emission CT (V-SPECT). Methods: In an IRB-approved clinical study, 14 patients undergoing thoracic radiotherapy received two successive single inhalation, single energy (80keV) CT images of the entire lung using 100% oxygen and a 70%/30% xenon-oxygen mixture. A subset of ten patients also received concurrent SPECT ventilation scans. Anatomic reproducibility between the two scans was achieved using a custom video biofeedback apparatus. The CT images were registered to each other by deformable registration, and a calculated difference image served as surrogate xenon ventilation map. Both lungs were partitioned into twelve sectors, and a sector-wise correlation was performed between the xenon and V-SPECT scans. A linear regression model was developed with forced expiratory volume (FEV) as a predictor and the coefficient of variation (CoV) as the outcome. Results: The ventilation comparison for five of the patients had either moderate to strong Pearson correlation coefficients (0.47 to 0.69, p<0.05). Of these, four also had moderate to strong Spearman correlation coefficients (0.46 to 0.80, p<0.03). The patients with the strongest correlation had clear regional ventilation deficits. The patient comparisons with the weakest correlations had more homogeneous ventilation distributions, and those patients also had diminished lung function as assessed by spirometry. Analysis of the relationship between CoV and FEV yielded a non-significant trend toward negative correlation (Pearson coefficient −0.60, p<0.15). Conclusion: Significant correlations were found between the Xe-CT and V-SPECT ventilation imagery. The results from this small cohort of patients indicate that single inhalation, single energy Xe-CT has the potential to

  9. Evaluation of the diagnostic performance of SPECT coupled to tomodensitometry (SPECT-CT) in the daily practice of bone scintigraphy at the Nuclear Medical station of Nancy

    International Nuclear Information System (INIS)

    Netter, F.; Journo, A.; Mayer, J.C.; Grandpierre, S.; Daragon, N.; Karcher, G.; Olivier, P.; Scigliano, S.

    2008-01-01

    Objective: The purpose of our study was to evaluate the diagnostic performance of SPECT coupled to computed axial tomography (SPECT- CT) in our daily practice of bone scintigraphy. Subjects and methods: SPECT- CT obtained as a complement to the planar bone scintigraphy in 39 patients were studied. Each type of image was retrospectively read by two different observers: a nuclear medicine physician who was unaware of SPECT- CT results analysed planar bone scintigraphy, a second one who was unaware of planar bone scintigraphy results analysed SPECT- CT images. In this population of patients, 17 patients were addressed in an oncologic setting. The 22 other patients were addressed for pain of indeterminate origin without neoplastic context. Results: In 13% of the cases, SPECT- CT specified the precise location of increased uptake foci seen on planar bone scintigraphy. In 38% of cases, SPECT- CT confirmed a diagnosis suspected by the planar bone scintigraphy. In 10% of cases, SPECT- CT established a diagnosis that was uncertain with planar bone scintigraphy. In 26% of cases, SPECT- CT brought no additional information. Finally in 3% of cases, SPECT- CT proved to be more sensitive than planar images. Conclusion: Our study demonstrates the utility of SPECT- CT in the daily practice of bone scintigraphy, this complementary imaging study benefited to 74% of our patients. (authors)

  10. Serial cerebral hemodynamic change after extracranial-intracranial (EC-IC) bypass surgery: evaluated by acetazolamide stress brain perfusion SPECT(acz-SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Il Ki; Kim, Jae Seung; Ahn, Jae Sung; Im, Ki Chun; Kim, Euy Nyong; Mun, Dae Hyeog [Asan Medical Center, Seoul (Korea, Republic of)

    2005-07-01

    We evaluated serial cerebral hemodynamic changes after EC-IC bypass surgery in symptomatic pts with atherosclerotic occlusion of internal carotid (lCA) or mid-cerebral artery (MCA) using Acz-SPECT. 25 symptomatic pts (M/F 19/6, 53{+-}10 y) with ICA and MCA occlusion (16 uni - and 9 bilateral) prospectively underwent Acz-SPECT using Tc-99m ECD before and 1 week after EC-IC bypass surgery. Of these, 16 underwent additional f/u Acz-SPECT 5 mo later. Cerebral perfusion and perfusion reserve of MCA territory were evaluated visually and SPECT findings were classified into 4 groups: N/N; R/N; N/R; and R/R (perfusion/perfusion reserve: N = normal, R = reduced). For semiquantitative analysis, all SPECT images were normalized to MNI template and mean counts of MCA territory and cerebellum were obtained by AAL. Cerebral perfusion index (PI =C{sub region}/C{sub cere}) and perfusion reserve index (RI = (PI{sub Acz} - PI{sub basal}) /Pl{sub basal}) were calculated. Preop SPECT findings of ipsilateral MCA in 25 pts were R/N (4%), N/R (12%), and R/R (84% ). Early postop SPECT showed improvement of perfusion (26%) and/or reserve (68%) in ipsilateral MCA. Of 16 pts with 5mo f/u SPECT, 6 (38%) showed further improvement of perfusion or reserve. However, 4 (25%) showed aggravation of perfusion and one of these underwent revision surgery. Preop PI (1.1{+-}0.1) and RI (0.11{+-}0.07) of ipsilateral MCA were significantly lower than those of contralateral hemispheres (p<0.05). After surgery, PIs of bilateral MCA did not change at early postop period but improved in ipsilateral MCA at 5mo. Rls of ipsilateral MCA increased significantly (68%) at early postop period (P<0.001) and then did not changed. Cerebral perfusion and perfusion reserve changed with different manner during 5 mo after bypass surgery and perfusion reserve changed more dramatically than perfusion. Acz-SPECT is a feasible method for evaluating cerebral hemodynamic change after EC-IC bypass surgery.

  11. SPECT in patients with cortical visual loss.

    Science.gov (United States)

    Silverman, I E; Galetta, S L; Gray, L G; Moster, M; Atlas, S W; Maurer, A H; Alavi, A

    1993-09-01

    Single-photon emission computed tomography (SPECT) with 99mTc-hexamethylpropyleneamine oxime (HMPAO) was used to investigate changes in cerebral blood flow in seven patients with cortical visual impairment. Traumatic brain injury (TBI) was the cause of cortical damage in two patients, cerebral ischemia in two patients and carbon monoxide (CO) poisoning, status epilepticus and Alzheimer's Disease (AD) each in three separate patients. The SPECT scans of the seven patients were compared to T2-weighted magnetic resonance image (MRI) scans of the brain to determine the correlation between functional and anatomical findings. In six of the seven patients, the qualitative interpretation of the SPECT studies supported the clinical findings (i.e., the visual field defect) by revealing altered regional cerebral blood flow (rCBF) in the appropriate regions of the visual pathway. MR scans in all of the patients, on the other hand, were either normal or disclosed smaller lesions than those detected by SPECT. We conclude that SPECT may reveal altered rCBF in patients with cortical visual impairment of various etiologies, even when MRI studies are normal or nondiagnostic.

  12. Noninvasive evaluation of ischemic stroke with SPECT

    International Nuclear Information System (INIS)

    Gomez, C.R.; Malik, M.M.; Gomez, S.M.; Wingkun, E.C.

    1988-01-01

    Technetium Tc 99m DTPA single photon emission computerized tomography (SPECT) brain scans of 20 patients with acute ischemic stroke were reviewed retrospectively and compared with clinical and radiologic (CT) data. Fourteen of the patients had abnormal SPECT studies. The abnormal findings were demonstrated by static views in eight patients, by the flow study in one patient, and by both sets of images in the other five patients. All abnormalities correlated with the clinical syndrome of presentation, and only two of the patients had no corresponding lesions on CT. Of the six patients with normal SPECT scans, two had abnormal CT studies, and in the other four, no lesions were shown at all. The ability of /sup 99m/Tc DTPA SPECT to display cerebral infarctions appears to be, at best, comparable to that of CT. SPECT also provides qualitative information regarding flow dynamics in the affected hemisphere of some patients (6/20 in our review). This, we believe, represents the objective demonstration of the preexisting insufficient collateral flow in the hemisphere at risk for ischemic stroke

  13. Quantitative assessment of 201TlCl myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa

    1987-01-01

    Clinical evaluation of the quantitative analysis of Tl-201 myocardial tomography by SPECT (Single Photon Emission Computed Tomography) was performed in comparison with visual evaluation. The method of quantitative analysis has been already reported in our previous paper. In this study, the program of re-standardization in the case of lateral myocardial infarction was added. This program was useful mainly for the evaluation of lesions in the left circumflex coronary artery. Regarding the degree of diagnostic accuracy of myocardial infarction in general, quantitative evaluation of myocardial SPECT images was highest followed by visual evaluation of myocardial SPECT images, and visual evaluation of myocardial planar images. However, in the case of anterior myocardial infarction, visual evaluation of myocardial SPECT images has almost the same detectability as quantitative evaluation of myocardial SPECT images. In the case of infero-posterior myocardial infarction, quantitative evaluation was superior to visual evaluation. As for specificity, quantitative evaluation of SPECT images was slightly inferior to visual evaluation of SPECT images. An infarction map was made by quantitative analysis and this enabled us to determine the infarction site, extent and degree according to easily recognizable patterns. As a result, the responsible coronary artery lesion could be inferred correctly and the calculated infarction score could be correlated with the residual left ventricular function after myocardial infarction. (author)

  14. The cerebral SPECT in the psychiatric dysfunctions in severe atopic dermatitis

    International Nuclear Information System (INIS)

    Ferrando, Rodolfo; Lago, Graciela; Vignale, Raul; Fabius, Bettina; Lyford Pike, Alexander

    2007-01-01

    Introduction: Severe atopic dermatitis (AD) usually has a psychiatric component that may influence the course of the cutaneous symptoms. Functional neuroimaging could evidence brain dysfunctions in this kind of patients. Objective: Evaluate the presence and characteristics of cerebral perfusion changes in severe AD patients using SPECT. Materials and methods: 11 severe AD patients were subjected to clinical psychiatric evaluation and 99mTc-ECD SPECT. Results: 90.3% of the patients presented a generalized anxiety disorder, 63.6% an obsessive compulsive disorder and 63.6% a depression. The 11 patients presented perfusion changes that prevailed at the prefrontal cortex. The alterations were concordant with the patterns described in those patients in which anxiety disorders and depression coexist. Conclusions: We demonstrate the frequent presence of perfusion changes in severe AD patients with psychiatric symptoms (au)

  15. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    International Nuclear Information System (INIS)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul

    2000-01-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.=20

  16. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.

  17. The assessment of whole body bone SPECT in oncology

    International Nuclear Information System (INIS)

    Scortechini, Shonika

    2009-01-01

    Full text: Objectives: To assess the significance and practicability of oncology whole body bone SPECT as part of the standard skeletal survey and its impact on the traditional planar whole body bone imaging protocol. Method: Three consenting oncology patients were injected with a standard adult dose of Tc-99m MOP. Delayed Imaging of whole body sweep and SPECT acquisitions were performed on a Siemens Symbia T6. The patient was positioned supine with arms down with a SPECT scan length covering vortex to thighs. SPECT data was reconstructed and a single whole body zipped file created. Normal SPECT slices along with a cine/MIP of the zipped data were created for review. Results: Both image data sets were reviewed to assess if SPECT provided any further diagnostic clinical information not apparent in planer imaging. In our limited review, whole body SPECT did not add extra value to the planar whole body scans performed; it did however demonstrate vertebral involvement with greater resolution. The processing software and system limitations in seamlessly knitting data sets (creating image artefacts) was a major limiting factor in not pursuing further studies. Conclusion: Both imaging techniques offer differing advantages and limitations, however due to image artefact in the triple knitted SPECT approach with current software technology, it cannot be substituted for whole body imaging at this time.

  18. Clinical application of SPECT-CT with 99mTc-Tektrotyd in bronchial and thymic neuroendocrine tumors (NETs).

    Science.gov (United States)

    Sergieva, Sonya; Robev, Bozhil; Dimcheva, Milena; Fakirova, Albena; Hristoskova, Radka

    2016-01-01

    Neuroendocrine tumors (NETs) of the thorax including bronchial and thymic tumors belong to foregut NETs. Limited loco-regional thoracic NETs can be resected with surgery, but in extensive metastatic disease the treatment is mainly palliative. A high incidence and density of somatostatin receptors (SSTR2, SSTR3, and SSTR5) are found in thoracic NETs. The purpose of this study was to evaluate the role of SPECT-CT somatostatin receptor scintigraphy (SRS) with 99mTc-Tektrotyd for imaging, staging and follow up of patients with bronchial and thymic neuroendocrine tumors. Forty-one patients with thoracic tumors with neuroendocrine differentiation were studied. Sixty-eight examinations including SPECT-CT studies of the neck and chest and/or abdomen and pelvis were carried out 2-4 hrs. post i.v. administration of aver-age 740 MBq activity dose of 99mTc-EDDA/HYNIC-TOC (Tektrotyd, Polatom). In all 41 investigated patients we obtained 81.25% (13/16), 88% (22/25) and 85.36% (35/41) of sensitivity, specificity and accuracy of this diagnostic approach, respectively. Somatostatin-receptor scintigraphy correctly identified all primary NETs located in the lungs and thymus. SPECT-CT studies with 99mTc-EDDA/HYNIC-TOC resulted in exact pre-surgical and pre-treatment N/M staging of bronchial and thymic NETs, except 2 cases with multiple hepatic metastases and 1 with massive suprarenal metastasis. It can be concluded that SPECT-CT with 99mTc-EDDA/HYNIC-TOC is a valuable tool for staging and follow-up of patients with thoracic NETs.

  19. Marchiafava-Bignami disease: a case studied with brain magnetic resonance and SPECT

    International Nuclear Information System (INIS)

    Cardozo Oliver, J.; Casas Parera, Ignacio; Libere, G.; Malagold, S.

    2006-01-01

    Objective: To show the correlation between brain magnetic resonance images (MRI) and single-photon-emission computed tomography (SPECT) in a patient with Marchiafava-Bignami (MB) disease. Background: MB disease is a rare disorder associated with chronic alcoholism. It is characterized by symmetric demyelination of corpus callosum (CC) and adjacent white matter. These lesions can be demonstrated both by computed tomography or/and MRI. Scarce information is available about MRI and SPECT according to the research done. Design/methods: A 79-year-old white man with a history of excessive alcohol consumption (predominantly wine) was admitted to our Institute. A decrease in his physical activity was evidenced in the two years prior to admission and in the last twelve months progressive dementia with hallucinations and severe apathy developed. On admission neurologic examination showed papillae pale in both eyes, left hearing loss, action tremor of upper limbs and proximal hyporeflexia with distal arreflexia of all four limbs was observed. Affectation of higher cortical functions was evident. Cerebrospinal fluid was normal and serology for syphilis and HIV were negative. Both renal and hepatic functions were normal. Brain MRI and SPECT were performed. The patient died 70 days after diagnosis of MB disease. Results: MRI scans of the brain showed multiple hyperintense T2-weighted lesions in white matter and basal ganglia. Cortical atrophy, especially in the fronto-temporal areas, and a CC thickness reduction were also observed. Sagittal view showed an irregular cavitation in the genu of the CC, hypointense and hyperintense on T1 and T2-weighted images respectively. The SPECT showed an abnormal low perfusion on both frontal lobes, left temporo-parietal lobes and right basal ganglia. Conclusion: The clinical features and MRI were consistent with the diagnosis of MB disease. MRI and SPECT studies showed the connection between the lesion in the CC and bilateral cortical

  20. Advances in SPECT Instrumentation (Including Small Animal Scanners). Chapter 4

    International Nuclear Information System (INIS)

    Di Domenico, G.; Zavattini, G.

    2009-01-01

    Fundamental major efforts have been devoted to the development of positron emission tomography (PET) imaging modality over the last few decades. Recently, a novel surge of interest in single photon emission computed tomography (SPECT) technology has occurred, particularly after the introduction of the hybrid SPECT-CT imaging system. This has led to a flourishing of investigations in new types of detectors and collimators, and to more accurate refinement of reconstruction algorithms. Along with SPECT-CT, new, fast gamma cameras have been developed for dedicated cardiac imaging. The existing gap between PET and SPECT in sensitivity and spatial resolution is progressively decreasing, and this trend is particularly apparent in the field of small animal imaging where the most important advances have been reported in SPECT tomographs. An outline of the basic features of SPECT technology, and of recent developments in SPECT instrumentation for both clinical applications and basic biological research on animal models is described. (author)

  1. 123I-amphetamine-SPECT in the diagnosis of neurological disorders

    International Nuclear Information System (INIS)

    Biersack, H.J.; Kreiten, K.; Hartmann, A.; Friedrich, G.; Linck, H.A.; Winkler, C.; Bonn Univ.; Rheinische Landesklinik, Bonn

    1985-01-01

    In contrast to conventional brain scintigraphy with sup(99m)Tc-pertechnetate, SPECT with 123 I-IMP enables visualization of the brain tissue itself. The relevance of this imaging technique was evaluated in 54 patients with cerebral disorders. SPECT of the brain was performed with a rotating gamma camera. In 6 of 24 epileptic patients, SPECT revealed foci consistent with EEG-findings which were, however, not detected by CCT. In 4 of 25 patients with cerebrovascular disease, hypoperfused areas were detected by SPECT despite negative results obtained with CCT. In 50% (10/20) of the patients with cerebrovascular disease, SPECT showed a greater functional extent of the lesions than CCT. In 3 patients with migraine and normal CCT, regional perfusion disturbancers were found. SPECT with 123 I-labeled amphetamines, therefore, enables diagnosis of functional perfusion disorders and metabolic disturbances that are not revealed by CCT. In addition, SPECT can be used to exactly demonstrate the functional extent of lesions detected by CCT. (orig.) [de

  2. 99mTc-ECD SPECT study in dementia and aphasia

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi

    1993-01-01

    We studied clinical significance of 99m Tc-L,L,-ethyl cysteine dimer ( 99m Tc-ECD) SPECT study in dementia and aphasia, and compared it with 99m Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in 99m Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in 99m Tc-HMPAO SPECT. The count rate ratios in 99m Tc-ECD and 99m Tc-HMPAO SPECT were correlated well with each other, and the contrast of the 99m Tc-ECD SPECT image was equivalent or slightly higher as compared with 99m Tc-HMPAO. Therefore, 99m Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author)

  3. I-123 Iofetamine SPECT scan in children with neurological disorders

    International Nuclear Information System (INIS)

    Flamini, J.R.; Konkol, R.J.; Wells, R.G.; Sty, J.R.

    1990-01-01

    I-123 Iofetamine (IMP) single photon emission computed tomography (SPECT) imaging of the brain in 42 patients (ages 14 days to 23 years) was compared with other localizing studies in children with neurological diseases. All had an EEG and at least one imaging study of the brain (computed tomography (CT) or magnetic resonance imaging (MRI), or both). Seventy-eight percent of the patients had an EEG within 24-72 hours of the IMP-SPECT scan. Thirty-five (83%) had a history of seizures, and the remainder had other neurological conditions without a history of seizures. In most cases, a normal EEG reading with normal CT or MRI result predicted a normal SPECT study. When the EEG was abnormal the majority of the IMP-SPECT scans were abnormal and localized the abnormality to the same region. A comparison with CT and MRI showed that structural abnormalities involving the cortex were usually well demonstrated with IMP-SPECT imaging. Structural lesions confined to the white matter were generally not detectable with IMP-SPECT. In a few cases, SPECT scans revealed abnormalities in deep brain areas not identified by EEG. IMP-SPECT imaging is a valuable technique for the detection and localization of abnormal cerebral metabolic activity in children with seizure disorders. A correlation with CT or MRI is essential for proper interpretation of abnormalities detected with IMP SPECT imaging

  4. Dopamine-transporter SPECT and Dopamine-D2-receptor SPECT in basal ganglia diseases

    International Nuclear Information System (INIS)

    Hesse, S.; Barthel, H.; Seese, A.; Sabri, O.

    2007-01-01

    The basal ganglia comprise a group of subcortical nuclei, which are essential for motor control. Dysfunction of these areas, especially in dopaminergic transmission, results in disordered movement and neurological diseases such as Parkinson's disease, Wilson's disease, or Huntington disease. Positron emission tomography and single photon emission computed tomography (SPECT) have enhanced the understanding of the underlying pathophysiology, but they much more contribute to the early differential diagnosis of patients suffering from Parkinsonian syndrome in routine care. The present article provides dopamine transporter and D 2 receptor SPECT findings in selected movement disorders. (orig.)

  5. Technical approach to improvement of SPECT images

    International Nuclear Information System (INIS)

    Fukukita, Hiroyoshi

    1985-01-01

    At present, a large number of SPECT systems are being widely used in Japan, hence, it is reasonable for us to know the physical and imaging characteristics of these SPECT devices, and also to recommend the optimum utility of SPECT systems. For this reason, a survey respect of characteristics of the commercialy available SPECT devices was carried out. In addition to this, various factors which have significant influence over SPECT image quality, such as, data acquisition matrix, reconstruction filter, γ-ray attenuation correction and daily quality control procedure, were also investigated. The materials used for this study are PET/SPECT phantom, Alderson liver phantom filled with Tc-99m solution, and either LFOV-E or ZLC-7500 interfaced to Scintipac 2400 minicomputer with 256 K byte of memory. Following are the results of this study. 1) The suitable data acquisition procedure was 128 x 128 matrix for linear sampling and approximately 64 views for angular sampling. 2) Reconstructed image using pre-processing filter with Wiener and Butterworth filters provided high quality image as compared with the Ramp filter. 3) Weighted backprojection method (WBP) proposed by Tanaka was superior to other methods, such as Sorenson method and Chang method in the object with non-uniform distribution of radionuclide. 4) It was found that uniformity correction of gamma camera and precise adjustment of the center of rotation are most important to maintain the images with a high quality. (author)

  6. PET and SPECT in neurology

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium). Dept. of Radiology and Nuclear Medicine; Vries, Erik F.J. de; Waarde, Aren van [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Otte, Andreas (ed.) [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology

    2014-07-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  7. PET and SPECT in neurology

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Ghent Univ.; Vries, Erik F.J. de; Waarde, Aren van; Otte, Andreas

    2014-01-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  8. Single photon emission computed tomography (SPECT) in seizure disorders in childhood

    International Nuclear Information System (INIS)

    Vles, J.S.H.; Demandt, E.; Ceulemans, B.; de Roo, M.; Casaer, P.J.M.

    1990-01-01

    In 38 children with partial seizures, the EEG, CT and NMR findings were compared to the results obtained with Tc99m HMPAO single photon emission computed tomography (SPECT) in order to determine whether SPECT is a useful adjunct to EEG, CT and NMR in this age group. In 3 out of 7 patients with a normal EEG, SPECT showed focal abnormalities. Nine patients whose EEGs did not show adequate lateralization had an abnormal SPECT which revealed a focus. In 14 out of 21 patients with a normal CT, SPECT showed focal changes in 13 patients and diffuse changes in the other one. In 7 out of 12 patients with a normal NMR, SPECT showed focal abnormalities. Although clinical history and a careful description of the seizures are the most valuable information in partial seizure disorders, SPECT imaging gives valuable additional information, which might target treatment. SPECT was superior to CT and NMR with respect to the depiction of some kind of abnormality. (author)

  9. Atlas of Skeletal SPECT/CT Clinical Images

    International Nuclear Information System (INIS)

    2016-01-01

    The atlas focuses specifically on single photon emission computed tomography/computed tomography (SPECT/CT) in musculoskeletal imaging, and thus illustrates the inherent advantages of the combination of the metabolic and anatomical component in a single procedure. In addition, the atlas provides information on the usefulness of several sets of specific indications. The publication, which serves more as a training tool rather than a textbook, will help to further integrate the SPECT and CT experience in clinical practice by presenting a series of typical cases with many different patterns of SPECT/CT seen in bone scintigraphy

  10. Does supplementation of contrast MR imaging with thallium-201 brain SPECT improve differentiation between benign and malignant ring-like contrast-enhanced cerebral lesions?

    International Nuclear Information System (INIS)

    Kita, Tamotsu; Hayashi, Katsumi; Yamamoto, Masayoshi; Kawauchi, Toshio; Sakata, Ikuko; Iwasaki, Yoshie; Kosuda, Shigeru

    2007-01-01

    The objective of this study was to determine whether thallium-201 ( 201 Tl) brain single photon emission computed tomography (SPECT) could supplement magnetic resonance (MR) imaging diagnostic information by visual comparison of two separate data sets from patients with ring-like contrast-enhanced cerebral lesions. A combination of MR imaging and 201 Tl brain SPECT sets obtained from 13 patients (10 men, 3 women) ranging in age from 26 years to 86 years (mean 61.0 years) were retrospectively reviewed. A total of 12 patients had a solitary lesion, and the others had multiple lesions. All but two intracranial foci were pathologically confirmed. The final diagnoses were six glioblastomas, two cerebral metastases from lung cancer, and one each of abscess, resolving hematoma, primary central nervous system lymphoma, toxoplasmosis, and radiation necrosis. The two separate image formats (MR images and SPECT) were shown to ten readers with practical experience. All of the MR images for each patient were shown to each reader first. After interpreting them, the readers were shown the SPECT images. Images were scored in terms of how benign or malignant the foci were on a 5-point scale from ''definitely benign'' to ''definitely malignant.'' The improvement in the performance of all ten readers was from 67.7% to 93.8% in mean accuracy (P=0.0028) and from 0.730 to 0.971 in mean Az value (P=0.0069) after they were shown the 201 Tl brain SPECT images. 201 Tl brain SPECT should substantially increase confidence in the diagnosis of intracranial lesions with ring-like contrast enhancement when MR imaging does not permit differentiation between benign and malignant disease. (author)

  11. The study of low level laser irradiation therapy on brain infarction with SPECT

    Institute of Scientific and Technical Information of China (English)

    Xiao Xuechang; Jia Shaowei; Zleng Xiyuan

    2000-01-01

    Objective: Effect of rCBF and brain function on ILIB treating brain infarction will be investigated by SPECT brain perfusion imaging. Method: 3 1 patients with brain infarction, 17 patients were treated by ILIB on standard pharmaceutial treatment. SPECT brain perfusion imaging was performed before and after ILIB therapy with comparison of oneself. They were quantified with BFCR% model effect during ILIB in 14 patients were observed. Result: ILIB 30 rnme SPECT showed the improvement of rCBF and cerebral function in 14 patients with brain infarction, and in 17 patients locus were prominence than mirror regions att er ILIB therapy, both are higher singnitficant difference ( t=4.4052, P<0.0001 ), but mirror regions were not singnificant difference before and after ILIB (t=1.6995, P>0.05). BFCR% quantitative results of locus were higher mirror regions, and higher singnificant difference (t=4.5278 p<0.0001 )。 Conclusion: ILIB can improve the rCBF and cerebral function of patients with brain infarction, and provoke function of brain cells. Some new evidence was provided for ILIB treatment of cerebral ischemia

  12. SPECT I-123 iodoamphetamine brain imaging

    International Nuclear Information System (INIS)

    Tikofsky, R.S.; Liebman, A.; Hellman, R.S.; Collier, B.D.; Voslar, A.M.

    1988-01-01

    SPECT/IMP studies of 100 patients with a presumptive diagnosis of dementia were performed with a rotating gamma camera 15-20 minutes after intravenous injection of 3.5 mCi of IMP. Of these studies, 43 were interpreted as normal for age; 28 demonstrated decreased but not absent activity bilaterally in posterior parietal/occipital regions (consistent with Alzheimer-type dementia); 28 showed unilateral abnormalities in regional cerebral blood flow consistent with cerebrovascular disease; and one had mixed findings. Based on SPECT/IMP results, further diagnostic testing and/or management would be altered for 72% of patients, suggesting that SPECT/IMP provides valuable data, not available on clinical examination, to guide the evaluation and management of demented patients

  13. Dopamine transporter imaging with [{sup 123}I]FP-CIT SPECT: potential effects of drugs

    Energy Technology Data Exchange (ETDEWEB)

    Booij, Jan [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Kemp, Paul [Southampton University Hospitals Trust, Department of Nuclear Medicine, Southampton (United Kingdom)

    2008-02-15

    [{sup 123}I]N-{omega}-fluoropropyl-2{beta}-carbomethoxy-3{beta}-{l_brace}4-iodophenyl{r_brace}nortropane ([{sup 123}I]FP-CIT) single photon emission computed tomography (SPECT) is a frequently and routinely used technique to detect or exclude dopaminergic degeneration by imaging the dopamine transporter (DAT) in parkinsonian and demented patients. This technique is also used in scientific studies in humans, as well as in preclinical studies to assess the availability of DAT binding in the striatum. In routine clinical studies, but also in scientific studies, patients are frequently on medication and sometimes even use drugs of abuse. Moreover, in preclinical studies, animals will be anesthetized. Prescribed drugs, drugs of abuse, and anesthetics may influence the visual interpretation and/or quantification of [{sup 123}I]FP-CIT SPECT scans. Here, we discuss the basic principle of how drugs and anesthetics might influence the visual interpretation and/or quantification of [{sup 123}I]FP-CIT SPECT scans. We also review drugs which are likely to have a significant influence on the visual interpretation and/or quantification of [{sup 123}I]FP-CIT SPECT scans. Additionally, we discuss the evidence as to whether frequently prescribed drugs in parkinsonian and demented patients may have an influence on the visual interpretation and/or quantification of [{sup 123}I]FP-CIT SPECT scans. Finally, we discuss our recommendations as to which drugs should be ideally withdrawn before performing a [{sup 123}I]FP-CIT SPECT scan for routine clinical purposes. The decision to withdraw any medication must always be made by the specialist in charge of the patient's care and taking into account the pros and cons of doing so. (orig.)

  14. Clinical applications of SPECT/CT in imaging the extremities

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Strobel, Klaus

    2014-01-01

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  15. Clinical applications of SPECT/CT in imaging the extremities

    Energy Technology Data Exchange (ETDEWEB)

    Huellner, Martin W. [University Hospital Zurich, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland)

    2014-05-15

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  16. Validation and the limits of SPECT for patients suffering from cerebrovascular accidents. Evaluations based on simultaneous PET and SPECT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1989-02-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO{sub 2}) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO{sub 2} during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO{sub 2} on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO{sub 2} value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO{sub 2} areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.).

  17. SPECT for smokers brain perfusion evaluation; SPECT para avaliacao da perfusao cerebral em fumantes

    Energy Technology Data Exchange (ETDEWEB)

    Maliska, C.M.; Martins, E.F.; Barros, D.S.; Lopes, M.M.S.; Lourenco, C.; Goncalves, S.; Goncalves, M.B.; Miranda, M.M.B.G.; Neto, L.M.; Penque, E.; Antonucci, J.B. [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil)

    2002-07-01

    Cigarette smoking increases brain stroke risk, however,five to fifteen years after ceasing this habit, brain perfusion recovers normal pattern. We propose to compare brain perfusion patterns performing brain SPECT scans of smokers and non-smokers. Thirteen volunteers age range 20-30 years old) composed of six non-smokers and seven smokers were studied by brain scans (SPECT).We used ECD- {sup 99m} Tc radiolabelled as recommended by the manufacturer. All patients received 740 MBq of the radiopharmaceutical through intravenous injection, with their eyes opened and their ears unplugged, in a quiet room. We used a one head SPECT camera ( General Electric/ StarCam 4000 and Siemens/ E.Cam) with low-energy ultrahigh resolution collimator. Imaging begin 40 minutes after tracer injection. For reconstruction we used a Butterworth filter.The preliminary results showed brain perfusion deficit areas on five of the smokers while all non- smokers had normal brain perfusion scans. We believe that smoking increases the possibility of brain perfusion deficits. (author)

  18. Evaluation of {sup 99m}Tc-ECD SPECT for the detection of brain tumor. Comparison with {sup 201}Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Motoo; Sasaki, Yasushi; Kikuchi, Yoshirou; Kaminaga, Tatsuro; Furui, Shigeru [Teikyo Univ., Tokyo (Japan). Faculty of Medicine; Konoeda, Kouichi; Karigome, Masato; Yoshida, Katsuhiko

    1997-01-01

    For the evaluation of brain tumor (n=15), we performed both dynamic and static {sup 99m}Tc-ECD (ECD) SPECT studies. {sup 201}Tl SPECT was also used for comparison with the results of ECD SPECT. Dynamic ECD SPECT was obtained following the injection of 600 MBq of ECD. Five min after the injection of ECD, static ECD SPECT was performed. {sup 201}Tl SPECT was obtained 10 min after the injection of 74 MBq. Abnormal uptake was recognized in 7 of 15 tumors with dynamic ECD; 5 of 7 meningiomas, 1 of 1 glioblastoma and 1 of 1 astrocytoma. However, no abnormal uptake was seen in 3 of 3 benign tumors (1 low grade astrocytoma, 1 hemangioma, 1 craniopharyngioma) and in 2 of 2 brain metastases. In contrast abnormal uptake was seen in 11 of 15 tumors with {sup 201}Tl; 7 of 7 meningiomas, 2 of 2 brain metastases, 1 of 1 glioblastoma and 1 of 1 craniopharyngioma. No abnormal uptake was seen in 3 of 3 benign tumors (1 hemangioma and 2 low grade astrocytomas). Equivocal uptake was seen in 1 low grade astrocytoma with dynamic ECD and {sup 201}Tl. The mechanism of the accumulation of dynamic ECD to brain tumor is unclear. However, it may reflect not only blood flow, but also metabolism. (author)

  19. Bone single photon emission computed tomography (SPECT in a patient with Pancoast tumor: a case report

    Directory of Open Access Journals (Sweden)

    Hamid Javadi

    Full Text Available CONTEXT: Non-small cell lung carcinomas (NSCLCs of the superior sulcus are considered to be the most challenging type of malignant thoracic disease. In this disease, neoplasms originating mostly from the extreme apex of the lung expand to the chest wall and thoracic inlet structures. Multiple imaging procedures have been applied to identify tumors and to stage and predict tumor resectability in surgical operations. Clinical examinations to localize pain complaints in shoulders and down the arms, and to screen for Horner's syndrome and abnormalities seen in paraclinical assessments, have been applied extensively for differential diagnosis of superior sulcus tumors. Although several types of imaging have been utilized for diagnosing and staging Pancoast tumors, there have been almost no reports on the efficiency of whole-body bone scans (WBBS for detecting the level of abnormality in cases of superior sulcus tumors. CASE REPORT: We describe a case of Pancoast tumor in which technetium-99m methylene diphosphonate (Tc-99m MDP bone single-photon emission-computed tomography (SPECT was able to accurately detect multiple areas of abnormality in the vertebrae and ribs. In describing this case, we stress the clinical and diagnostic points, in the hope of stimulating a higher degree of suspicion and thereby facilitating appropriate diagnosis and treatment. From the results of this study, further clinical trials to evaluate the potential of SPECT as an efficient imaging tool for the work-up on cases of Pancoast tumor are recommended.

  20. Interest of hybrid SPECT-CT imaging for diagnosis of infection

    International Nuclear Information System (INIS)

    Riviere, A.; Farid, K.; Guyot, M.; Jeandot, R.; Allard, M.; Fernandez, P.; Clermont, H. de; Dauchy, F.; Dupon, M.; Fernandez, P.

    2008-01-01

    Single-Photon Emission Computed Tomography-Computerized Tomography (SPECT-CT) is a new hybrid technique which offers new diagnostic capabilities in daily nuclear medicine practice. This technique not only allows to acquire merged anatomic and functional images in the same time, but also, it increases sensitivity and accuracy of SPECT thanks to attenuation and scattering corrections got from transmission data. Until now, SPECT-CT data have been mainly obtained in oncology and cardiology, but now, many authors use it in many scan studies and particularly for infectious diseases. In inflammatory bowel diseases, SPECT-CT seems to increase diagnostic performances and to modify management of many patients. In suspected vascular sepsis, SPECT-CT could increase sensitivity of white blood cell scintigraphy but also its specificity thanks to spatial resolution of CT. In osteo-articular sepsis, SPECT-CT has the advantage to distinguish osteomyelitis from soft tissue infection and to guide biopsies. Nevertheless, in the light of PET-CT works, SPECT-CT development will probably modify nuclear medicine practice and many studies have to be conducted to highlight consensual procedure guidelines. (authors)

  1. Diagnostic impact of SPECT-CT in the assessment of endocrine tumors

    International Nuclear Information System (INIS)

    El Badaoui, A.; Clermont, H. de; Valli, N.; Caignon, J.M.; Fernandez, P.; Allard, M.; Barat, J.L.; Ducassou, D.; Clermont, H. de; Valli, N.; Caignon, J.M.; Fernandez, P.; Allard, M.; Barat, J.L.; Ducassou, D.; Clermont, H. de; Allard, M.

    2008-01-01

    Image fusion using single photon emission computed tomography - computed tomography (SPECT - CT) associates functional and morphological images. This study evaluates the added value of SPECT- CT, obtained with a hybrid SPECT- CT gamma camera, on anatomic localization and diagnostic impact in assessment of endocrine tumours and pheochromocytomas. Method: Six months prospective study was undertaken including 33 consecutive exams encompassing 20 Somatostatin Receptor Scintigraphies (S.R.S.) and 13 123 I-meta-iodo-benzyl-guanidine (Mibg) scans. Two experienced nuclear medicine physicians independently analysed independently planar and SPECT images in a first time, then, SPECT- CT fused images in a second time. They evaluated two parameters: SPECT- CT impact on anatomic localization (L.A.) and its diagnostic impact (I.D.). Each parameter was scored according three levels of evaluation. Results: An added value of SPECT- CT images was evidenced in 55% of cases on the anatomic localization and in 41% of the patients on the diagnostic impact. Therefore, a more important benefit was noted when SPECT was positive (L.A.: 90%; I.D.: 70%) than when it was negative (L.A.: 15%; I.D.: 8%). Furthermore, the added value proved higher for the S;R.S. compared to Mibg scans. Conclusion: SPECT- CT fusion images obtained by a hybrid system is more relevant to determine anatomic localization and more accurate than SPECT alone, particularly in the assessment of endocrine tumours. The added value of SPECT- CT seems to be lower for Mibg scans in the assessment of pheochromocytomas. (authors)

  2. Organ volume estimation using SPECT

    CERN Document Server

    Zaidi, H

    1996-01-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang's algorithm. The dual-window method was used for scatter subtraction. We used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of 1) fixed thresholding, 2) automatic thresholding, 3) attenuation, 4) scatter, and 5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are perform...

  3. SPECT and PET imaging in epilepsia; SPECT und PET in der Diagnostik von Epilepsien

    Energy Technology Data Exchange (ETDEWEB)

    Landvogt, C. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2007-09-15

    In preoperative localisation of epileptogenic foci, nuclear medicine diagnostics plays a crucial role. FDG-PET is used as first line diagnostics. In case of inconsistent MRI, EEG and FDG-PET findings, {sup 11}C-Flumazenil-PET or ictal and interictal perfusion-SPECT should be performed. Other than FDG, Flumazenil can help to identify the extend of the region, which should be resected. To enhance sensitivity and specificity, further data analysis using voxelbased statistical analyses or SISCOM (substraction ictal SPECT coregistered MRI) should be performed.

  4. Tc-99m MAG3 SPECT on transplanted kidney

    International Nuclear Information System (INIS)

    Ryu, Jong Gul; Kim, Soon; Zeon, Seok Kil

    1999-01-01

    This study was designed to evaluate the usefulness of a technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) single photon emission computed tomography (SPECT) performed on transplanted kidney. Thirty renal transplant patients were included in this study. Planar scan was performed for 30 minutes using 555 MBq Tc-99m MAG3. A post-voiding SPECT scan was acquired on the third, seventh, fourteenth and twenty eighth day after transplantation. SPECT scan showed interpretable image quality in 26 of 30 patients (86.7%) and 84 in 120 scans (70%). Fourteen of 26 patients with interpretable SPECT image showed decreased or increased radioactivity, but only 5 had abnormal findings on the planar scan. Focal SPECT defects were seen in allografts with normal function (n=3), acute tubular necrosis (n=3), and acute rejection (n=2). The defects are thought to reflect focally underperfused renal parenchyme or, in normal allografts, an artifact from uneven radioactivity distribution. Four of 10 paints with renal arterial variation showed focally decreased radioactivity and SPECT helped guide further studies that confirmed the exact cause. Five of 10 patients with acute tubular necrosis or acute rejection showed focally decreased radioactivity, but its relation to the patients' clinical course was not clear. Focally increased radioactivity was observed in 5 allografts with normal function and 1 with double ureter in which local clearance delay was observed. Tc-99m MAG3 SPECT renal scan can detect additional focal abnormalities compared to planar scan. Further study is necessary to elucidate the exact clinical significance of the SPECT findings

  5. 99mTc-HMPAO SPECT in brain death

    International Nuclear Information System (INIS)

    Tsuchida, Tatsuro; Sadato, Norihiro; Nishizawa, Sadahiko

    1993-01-01

    Brain single photon emission computed tomography (SPECT) with 99m Tc-d,l-hexamethyl-propyleneamine oxime (HMPAO) was performed twice in a 78-year-old man clinically diagnosed as brain death according to the standard criteria of the Japanese Ministry of Welfare. The first brain SPECT demonstrated the tracer accumulation in the brain, indicating preserved cerebral blood flow. The second brain SPECT performed 3 days later revealed cessation of the blood flow. In patients with preserved cerebral blood flow, the diagnosis of brain death cannot be made, even if they meet the existing criteria, because previous report noted the recovery in some of those patients. Brain perfusion SPECT plays an important role as a confirmatory test for the diagnosis of brain death. (author)

  6. Effect of STA-MCA bypass based on the motor activation SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    The effect of STA-MCA bypass for ischemic cerebrovascular diseases (CVDs) on pure motor function using motor activation SPECT was evaluated and analyzed, and this effect with the resting cerebral blood flow and reserved capacity was compared. Motor activation SPECT were carried out on 22 cases with STA-MCA bypass for symptomatic ischemic CVDs. All motors activation SPECT using the finger opposition task on the affected side were performed before bypass, at 1 month, and 3 months after the bypass. Visual inspection was used to determine whether the result of the motor activation SPECT was as negative or positive. The activated region was detected anatomically precisely by superimposing the SPECT on the MRI. Before this study, the same examination was performed on normal controls. In controls, 91% showed the activated area on the sensorimotor cortex after the finger opposition tasks. Before bypass, the resting SPECT revealed reduction of cerebral blood flow (CBF) on the affected side in all cases. All cases also showed a disturbed response to acetazolamide (ACZ). Nine cases were positive in the motor activation SPECT. One month after bypass, the resting CBF increased in 11 cases. Seven showed preoperative positive motor activation. Fifteen cases were positive in the motor activation SPECT. Three months after bypass, 20 cases showed improvement in the resting CBF, and 19 cases were positive in the motor activation SPECT. Ten cases were negative in the preoperative motor activation SPECT. At one month after surgery, ACZ activation SPECT was performed in 12 cases. Five showed improvement of the response to ACZ. At 3 months after surgery, 8 of 12 cases treated with ACZ activation SPECT showed improved response to ACZ. In most of the cases, improved response to ACZ could be seen after response to motor activation improved. STA-MCA bypass is useful not only for resting CBF but also for pure motor function based on motor activation SPECT. (K.H.)

  7. Effect of STA-MCA bypass based on the motor activation SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-07-01

    The effect of STA-MCA bypass for ischemic cerebrovascular diseases (CVDs) on pure motor function using motor activation SPECT was evaluated and analyzed, and this effect with the resting cerebral blood flow and reserved capacity was compared. Motor activation SPECT were carried out on 22 cases with STA-MCA bypass for symptomatic ischemic CVDs. All motors activation SPECT using the finger opposition task on the affected side were performed before bypass, at 1 month, and 3 months after the bypass. Visual inspection was used to determine whether the result of the motor activation SPECT was as negative or positive. The activated region was detected anatomically precisely by superimposing the SPECT on the MRI. Before this study, the same examination was performed on normal controls. In controls, 91% showed the activated area on the sensorimotor cortex after the finger opposition tasks. Before bypass, the resting SPECT revealed reduction of cerebral blood flow (CBF) on the affected side in all cases. All cases also showed a disturbed response to acetazolamide (ACZ). Nine cases were positive in the motor activation SPECT. One month after bypass, the resting CBF increased in 11 cases. Seven showed preoperative positive motor activation. Fifteen cases were positive in the motor activation SPECT. Three months after bypass, 20 cases showed improvement in the resting CBF, and 19 cases were positive in the motor activation SPECT. Ten cases were negative in the preoperative motor activation SPECT. At one month after surgery, ACZ activation SPECT was performed in 12 cases. Five showed improvement of the response to ACZ. At 3 months after surgery, 8 of 12 cases treated with ACZ activation SPECT showed improved response to ACZ. In most of the cases, improved response to ACZ could be seen after response to motor activation improved. STA-MCA bypass is useful not only for resting CBF but also for pure motor function based on motor activation SPECT. (K.H.)

  8. The clinical use of brain SPECT imaging in neuropsychiatry

    International Nuclear Information System (INIS)

    Amen, Daniel G; Wu, Joseph C; Carmichael, Blake

    2003-01-01

    This article reviews the literature on brain SPECT imaging in brain trauma, dementia, and temporal lobe epilepsy. Brain SPECT allows clinicians the ability to view cerebral areas of healthy, low, and excessive perfusion. This information can be correlated with what is known about the function or dysfunction of each area. SPECT has a number of advantages over other imaging techniques, including wider availability, lower cost, and high quality resolution with multi-headed cameras. There are a number of issues that compromise the effective use of SPECT, including low quality of some imaging cameras, and variability of image rendering and readings (Au)

  9. The effect of Compton scattering on quantitative SPECT imaging

    International Nuclear Information System (INIS)

    Beck, J.W.; Jaszczak, R.J.; Starmer, C.F.

    1982-01-01

    A Monte Carlo code has been developed to simulate the response of a SPECT system. The accuracy of the code has been verified and has been used in this research to study and illustrate the effects of Compton scatter on quantitative SPECT measurements. The effects of Compton scattered radiation on gamma camera response have been discussed by several authors, and will be extended to rotating gamma camera SPECT systems. The unique feature of this research includes the pictorial illustration of the Compton scattered and the unscattered components of the photopeak data on SPECT imaging by simulating phantom studies with and without Compton scatter

  10. Clinical evaluation of coronary territory map by using unfolded map of Tl-201 myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa; Nishimura, Tsunehiko; Katafuchi, Tetsuro; Yamagami, Hidetoshi; Kumita, Shinichirou; Hayashida, Kohei; Hayashi, Makoto

    1990-01-01

    Coronary territory map was developed on unfolded map of exercise Tl-201 myocardial SPECT. Each coronary territory was determined by summing the each unfolded map of 54 cases of single vessel disease respectively, and standardizing with normal pattern obtained from normal patients. The diagnostic accuracy of coronary territory map to identify the diseased coronary artery was analyzed in 104 clinical cases and was compared with that of planar and SPECT visual diagnosis, simple unfolded map (raw map) and extent and severity map. The results were as follows. (1) Territory map showed excellent diagnostic accuracy in single or double vessel disease, especially in diagnosis of left circumflex coronary artery lesion. (2) In triple vessel disease, the diagnostic accuracy of territory map or other unfolded maps was 30% at best, and was inferior to planar or SPECT visual analysis. The cause of this inferiority seemed that the quantitatively analyzed map had no information about the degree of Tl-uptake into lung or myocardium, which give useful information in visual diagnosis. (3) The diagnostic agreement ratio in two observers was the highest in territory map diagnosis, so that the territory map diagnosis seemed to be the most objective one. (4) The unfolded map diagnosis with apical display obtained from long-axis tomogram was useful to diagnose left anteior descending coronary (LAD) lesion, which improve not only the sensitivity of LAD but also specificity of right coronary artery single vessel disease. (author)

  11. Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT.

    Science.gov (United States)

    Armstrong, Ian S; Hoffmann, Sandra A

    2016-11-01

    The interest in quantitative single photon emission computer tomography (SPECT) shows potential in a number of clinical applications and now several vendors are providing software and hardware solutions to allow 'SUV-SPECT' to mirror metrics used in PET imaging. This brief technical report assesses the accuracy of activity concentration measurements using a new algorithm 'xSPECT' from Siemens Healthcare. SPECT/CT data were acquired from a uniform cylinder with 5, 10, 15 and 20 s/projection and NEMA image quality phantom with 25 s/projection. The NEMA phantom had hot spheres filled with an 8 : 1 activity concentration relative to the background compartment. Reconstructions were performed using parameters defined by manufacturer presets available with the algorithm. The accuracy of activity concentration measurements was assessed. A dose calibrator-camera cross-calibration factor (CCF) was derived from the uniform phantom data. In uniform phantom images, a positive bias was observed, ranging from ∼6% in the lower count images to ∼4% in the higher-count images. On the basis of the higher-count data, a CCF of 0.96 was derived. As expected, considerable negative bias was measured in the NEMA spheres using region mean values whereas positive bias was measured in the four largest NEMA spheres. Nonmonotonically increasing recovery curves for the hot spheres suggested the presence of Gibbs edge enhancement from resolution modelling. Sufficiently accurate activity concentration measurements can easily be measured on images reconstructed with the xSPECT algorithm without a CCF. However, the use of a CCF is likely to improve accuracy further. A manual conversion of voxel values into SUV should be possible, provided that the patient weight, injected activity and time between injection and imaging are all known accurately.

  12. PET and SPECT of neurobiological systems

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Gent Univ. (Belgium). Dept. of Nuclear Medicine; Otte, Andreas [Univ. of Applied Sciences, Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-04-01

    Addresses a variety of aspects of neurotransmission in the brain. Details the latest results in probe development. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, ?-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed. Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology''.

  13. /sup 123/I-amphetamine-SPECT in the diagnosis of neurological disorders

    Energy Technology Data Exchange (ETDEWEB)

    Biersack, H.J.; Kreiten, K.; Hartmann, A.; Friedrich, G.; Linck, H.A.; Winkler, C.

    1985-03-01

    In contrast to conventional brain scintigraphy with sup(99m)Tc-pertechnetate, SPECT with /sup 123/I-IMP enables visualization of the brain tissue itself. The relevance of this imaging technique was evaluated in 54 patients with cerebral disorders. SPECT of the brain was performed with a rotating gamma camera. In 6 of 24 epileptic patients, SPECT revealed foci consistent with EEG-findings which were, however, not detected by CCT. In 4 of 25 patients with cerebrovascular disease, hypoperfused areas were detected by SPECT despite negative results obtained with CCT. In 50% (10/20) of the patients with cerebrovascular disease, SPECT showed a greater functional extent of the lesions than CCT. In 3 patients with migraine and normal CCT, regional perfusion disturbancers were found. SPECT with /sup 123/I-labeled amphetamines, therefore, enables diagnosis of functional perfusion disorders and metabolic disturbances that are not revealed by CCT. In addition, SPECT can be used to exactly demonstrate the functional extent of lesions detected by CCT.

  14. Study on SPECT image for children with cerebral infarction

    International Nuclear Information System (INIS)

    Xie Wenhuang; Xie Zhichun; Chen Yucai; Lin Haoxue; Zheng Aidong; Xie Hui

    1998-01-01

    To explore the diagnostic value of SPECT image for children with cerebral infarction (CCI), comparative research was made on 26 cases undergoing regional cerebral perfusion (rCP) image between SPECT imaging and CT scanning. The results showed that the rCP in the infarct and its distant area was decreased. The positive rate of SPECT and CT were 92.3% (24/26) and 84.5% (22/26) respectively. The difference was not significant (P = 0.67, P>0.05). But, the positive rate of SPECT image 2 days after onset in 9 CCI was 100% (9/9), significantly higher than 55.6% (5/9) in CT scanning (P = 0.04, P<0.05). These findings suggested that the SPECT imaging is a sensitive method for the early diagnosis of CCI, and also helpful for observation of the therapeutic effect and evaluation of the prognosis

  15. Usefulness of brain SPECT

    International Nuclear Information System (INIS)

    Raynaud, C.; Rancurel, G.; Kieffer, E.; Ricard, S.; Askienazy, S.; Moretti, J.L.; Bourdoiseau, M.; Rapin, J.; Soussaline, F.

    1983-01-01

    Brain SPECT was not effectively exploited until I-123 isopropyl amphetamine (IAMP), indicator able to penetrate the blood brain barrier, became available. Although the experience of research teams working with IAMP is quite restricted due to the high cost of the indicator, some applications now appear to be worth the cost and in some cases provide data which cannot be obtained with routine techniques, especially in cerebrovascular patients, in epilepsy and some cases of tumor. Brain SPECT appears as an atraumatic test which is useful to establish a functional evaluation of the cerebral parenchyma, and which is a complement to arteriography, X-ray scan and regional cerebral blood flow measurement

  16. Influence of void on image quality of industrial SPECT

    International Nuclear Information System (INIS)

    Park, J G; Jung, S H; Kim, J B; Moon, J; Kim, C H

    2013-01-01

    Industrial single photon emission computed tomography (SPECT) is a promising technique to determine the dynamic behavior of industrial process media and has been developed in the Korea Atomic Energy Research Institute. The present study evaluated the influence of a void, which is presence in multiphase reactors of industrial process, on the image quality of an industrial SPECT. The results are very encouraging; that is, the performance of the industrial SPECT system is little influenced by the presence of a void, which means that industrial SPECT is an appropriate tool to estimate the dynamic characteristics of the process media in a water-air phase bubble column with a static gas sparger

  17. Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with 99mTc

    International Nuclear Information System (INIS)

    Gaudin, Émilie; Montégiani, Jean-François; Després, Philippe; Beauregard, Jean-Mathieu

    2014-01-01

    While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. 99m Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with 99m Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications

  18. The group study of diagnostic efficacy of cerebro-vascular disease by I-123 IMP SPECT images obtained with ring type SPECT scanner

    International Nuclear Information System (INIS)

    Machida, Kikuo; Honda, Norinari; Matsumoto, Toru

    1991-01-01

    We performed two image reading experiments in order to investigate the diagnostic capability of I-123 IMP SPECT obtained by the ring type SPECT scanner in cerebro-vascular disease. Fourteen physicians diagnosed SPECT images of 55 cases with reference to clinical neurological information, first without brain XCT images and second with XCT images. Each physician detected perfusion defects and redistributions of I-123 IMP and assigned a confidence level of abnormality for these SPECT findings by means of five rating method. From results obtained by ROC analysis, we concluded as follows. (1) Generally, I-123 IMP SPECT is a stable diagnostic modality in the diagnosis of cerebro-vascular disease and the image reading of XCT had no effects on the diagnosis of SPECT on the whole of physician. (2) However, there were unnegligible differences among individuals in the detectability of findings and the effect of XCT image reading. (3) Detectability of redistribution of I-123 IMP was lower than that of perfusion defect and inter-observer variation in the diagnostic performance for redistribution was larger than that of perfusion defect. The results suggest that it is necessary to standardize diagnostic criteria among physicians for redistribution of I-123 IMP. (author)

  19. Clinical use of digital retrospective image fusion of CT, MRI, FDG-PET and SPECT - fields of indications and results

    International Nuclear Information System (INIS)

    Lemke, A.J.; Niehues, S.M.; Amthauer, H.; Felix, R.; Rohlfing, T.; Hosten, N.

    2004-01-01

    Purpose: To evaluate the feasibility and the clinical benefits of retrospective digital image fusion (PET, SPECT, CT and MRI). Materials and methods: In a prospective study, a total of 273 image fusions were performed and evaluated. The underlying image acquisitions (CT, MRI, SPECT and PET) were performed in a way appropriate for the respective clinical question and anatomical region. Image fusion was executed with a software program developed during this study. The results of the image fusion procedure were evaluated in terms of technical feasibility, clinical objective, and therapeutic impact. Results: The most frequent combinations of modalities were CT/PET (n = 156) and MRI/PET (n = 59), followed by MRI/SPECT (n = 28), CT/SPECT (n = 22) and CT/MRI (n = 8). The clinical questions included following regions (more than one region per case possible): neurocranium (n = 42), neck (n = 13), lung and mediastinum (n = 24), abdomen (n = 181), and pelvis (n = 65). In 92.6% of all cases (n = 253), image fusion was technically successful. Image fusion was able to improve sensitivity and specificity of the single modality, or to add important diagnostic information. Image fusion was problematic in cases of different body positions between the two imaging modalities or different positions of mobile organs. In 37.9% of the cases, image fusion added clinically relevant information compared to the single modality. Conclusion: For clinical questions concerning liver, pancreas, rectum, neck, or neurocranium, image fusion is a reliable method suitable for routine clinical application. Organ motion still limits its feasibility and routine use in other areas (e.g., thorax). (orig.)

  20. Anatomically standardized statistical mapping of 123I-IMP SPECT in brain tumors

    International Nuclear Information System (INIS)

    Shibata, Yasushi; Akimoto, Manabu; Matsushita, Akira; Yamamoto, Tetsuya; Takano, Shingo; Matsumura, Akira

    2010-01-01

    123 I-iodoamphetamine Single Photon Emission Computed Tomography (IMP SPECT) is used to evaluate cerebral blood flow. However, application of IMP SPECT to patients with brain tumors has been rarely reported. Primary central nervous system lymphoma (PCNSL) is a rare tumor that shows delayed IMP uptake. The relatively low spatial resolution of SPECT is a clinical problem in diagnosing brain tumors. We examined anatomically standardized statistical mapping of IMP SPECT in patients with brain lesions. This study included 49 IMP SPECT images for 49 patients with brain lesions: 20 PCNSL, 1 Burkitt's lymphoma, 14 glioma, 4 other tumor, 7 inflammatory disease and 3 without any pathological diagnosis but a clinical diagnosis of PCNSL. After intravenous injection of 222 MBq of 123 I-IMP, early (15 minutes) and delayed (4 hours) images were acquired using a multi-detector SPECT machine. All SPECT data were transferred to a newly developed software program iNeurostat+ (Nihon Medi-physics). SPECT data were anatomically standardized on normal brain images. Regions of increased uptake of IMP were statistically mapped on the tomographic images of normal brain. Eighteen patients showed high uptake in the delayed IMP SPECT images (16 PCNSL, 2 unknown). Other tumor or diseases did not show high uptake of delayed IMP SPECT, so there were no false positives. Four patients with pathologically proven PCNSL showed no uptake in original IMP SPECT. These tumors were too small to detect in IMP SPECT. However, statistical mapping revealed IMP uptake in 18 of 20 pathologically verified PCNSL patients. A heterogeneous IMP uptake was seen in homogenous tumors in MRI. For patients with a hot IMP uptake, statistical mapping showed clearer uptake. IMP SPECT is a sensitive test to diagnose of PCNSL, although it produced false negative results for small posterior fossa tumor. Anatomically standardized statistical mapping is therefore considered to be a useful method for improving the diagnostic

  1. Clinical evaluation of lung rest/stress perfusion scintigraphy in patients with severe emphysema

    International Nuclear Information System (INIS)

    Hadjikostova, Hr.

    1998-01-01

    Volume lung reduction surgery (LVRS) improves lung function and physical tolerance for selected patients with severe pulmonary emphysema by making conditions for developing of the vital parenchyma so far compressed by the emphysema blisters. The aim of this study was to establish the comparative functional information obtained from REST/STRESS lung perfusion tomoscintigraphies for identification of non functional lung tissue. Eleven patients (8 males and 3 females at age 41-60) were examined by two lung perfusions SPECT scintigraphies after intravenous application of 222 MBq 99m Tc-MAA: 1. after 30 min. lying rest and 2. 48 hours later after 6 min. walk test. Comparing the two scintigraphies the following changes in perfusion performance have been established at STRESS examination: increased at six patients (significant at three and slight also at three) and decreased at two. There was no difference between REST and STRESS examinations at 3 patients. Comparative REST/STRESS lung perfusion scintigraphy is important method for screening severe pulmonary patients for LVRS. (author)

  2. Importance of brain perfusion SPECT in the diagnosis and prognosis of migraine

    International Nuclear Information System (INIS)

    Colmenter, L.F.; Paz-Araviche, V.; Celedon-Arrieta, P.; Mora, E.; Tavares, A.

    2002-01-01

    Aim: The objective of this investigation was to establish the usefulness of ECD-99mTc brain perfusion SPECT in the evaluation of the diagnosis of functional alterations of Vascular Headaches of migrainous origin and to determine the changes in regional cerebral blood flow (FSCr) during the headache phase. Material and Methods: A population of 21 female patients, 5 controls, of the same age and sex, aged between 20 and 76 years, with clinical evidence of headache with or without aura, with a duration of 8 to 72 hours, pulsating pain, associated to nausea, photophobia, phonophobia, that does not resolve with common analgesics and characterized by increase of the pain with physical activity. Brain perfusion SPECT was practiced on them at the moment of crisis, independent of the presence of aura or pain, and without crisis. ECD-99mTc was administered at a dose of 925 to 1110 MBq. Images were analyzed by the semi quantification method. Results: SPECT detected 13 hypo-captures on the 16 patients studied. With an 81% sensitivity and 100% specificity, with a precision value of 86%. Analysis through X Binomial Aleatory Variable showed a precision of 90% (p= < 0,023) for the isotopic test, with a significance level of 5%. Conclusions: The results of this study confirm that brain SPECT is a neuroimaging technique capable of identifying migrainous patients, being able to reevaluate the type of hypo perfusion that each patient has, during crisis or out of crisis, and correlate the cortical perfusion deficits and the deterioration of neuropsychological functions

  3. "Shin splint" syndrome and tibial stress fracture in the same patient diagnosed by means of (99m)Tc-HMDP SPECT/CT.

    Science.gov (United States)

    Vicente, Justo Serrano; Grande, Maria Luz Domínguez; Torre, Jose Rafael Infante; Madrid, Juan Ignacio Rayo; Barquero, Carmen Durán; Bernardo, Lucía García; Sánchez, Román Sánchez

    2013-04-01

    We show a patient who presented leg pain triggered by intense exercise. The most likely diagnosis was a possible tibial stress fracture or a "shin splint" syndrome (soleus enthesopathy). We performed a bone scintigraphy including SPECT/CT that revealed the presence of the two concomitant pathologies. SPECT/CT identified the hot spot superimposed with bone lesion in the tibial stress fracture and only remodeling activity without evidence of cortical lesions in the enthesopathy processes.

  4. Blood lipid levels and SPECT of myocardium perfusion to type 2 asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Pena Quian, Yamile; Fernandez-Britto Rodriguez, Jose; Coca Perez, Marco A; Batista Cuellar, Juan F; Rochela Vazquez, Luis Manuel

    2006-01-01

    SPECT, coronary angiography and laboratories test were performed on 31 asymptomatic type 2 diabetes patients, in order to determine the relationship among the lipid levels in blood and the results of the SPECT. Patients were classified in two groups (positive SPECT or negative SPECT). Simple descriptive statistics were calculated for all variables in both groups. Positive SPECT was detected in 35,5% of the patients and negative SPECT in 64,5%.The coronary angiography and SPECT showed good correlation. Low values of HDLc showed significant association with the positive results of the SPECT. The logistical regression showed an increment of the capacity to predict a positive SPECT if the values of HDLc are used. Conclusion: The present investigation demonstrated a significant association among the low levels of HDLc in blood and the positive results of the SPECT. The low values of HDLc could predict the possibility of a positive SPECT in asymptomatic diabetic type 2 patients (au)

  5. IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification.

    Science.gov (United States)

    Konishi, Takahiro; Nakajima, Kenichi; Okuda, Koichi; Yoneyama, Hiroto; Matsuo, Shinro; Shibutani, Takayuki; Onoguchi, Masahisa; Kinuya, Seigo

    2017-07-01

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 ( 201 Tl) myocardial perfusion imaging (MPI). A total of 36 patients underwent 1-day 201 Tl adenosine stress-rest MPI. Images were acquired with IQ-SPECT at approximately one-quarter of the standard time of conventional SPECT. Projection data acquired with the IQ-SPECT system were reconstructed via an ordered subset conjugate gradient minimizer method with or without scatter and attenuation correction (SCAC). Projection data obtained using the conventional SPECT were reconstructed via a filtered back projection method without SCAC. The summed stress score (SSS) was calculated using NDBs created by the Japanese Society of Nuclear Medicine working group, and scores were compared between IQ-SPECT and conventional SPECT using the acquisition condition-matched NDBs. The diagnostic performance of the methods for the detection of coronary artery disease was also compared. SSSs were 6.6 ± 8.2 for the conventional SPECT, 6.6 ± 9.4 for IQ-SPECT without SCAC, and 6.5 ± 9.7 for IQ-SPECT with SCAC (p = n.s. for each comparison). The SSS showed a strong positive correlation between conventional SPECT and IQ-SPECT (r = 0.921 and p IQ-SPECT with and without SCAC was also good (r = 0.907 and p IQ-SPECT without SCAC; and 88.5, 86.8, and 87.3%, respectively, for IQ-SPECT with SCAC, respectively. The area under the curve obtained via receiver operating characteristic analysis were 0.77, 0.80, and 0.86 for conventional SPECT, IQ-SPECT without SCAC, and IQ-SPECT with SCAC, respectively (p = n.s. for each comparison). When appropriate NDBs were used, the diagnostic performance of 201 Tl IQ-SPECT

  6. SU-D-202-01: Functional Lung Avoidance and Response-Adaptive Escalation (FLARE) RT: Feasibility of a Precision Radiation Oncology Strategy

    International Nuclear Information System (INIS)

    Bowen, S; Lee, E; Miyaoka, R; Kinahan, P; Sandison, G; Vesselle, H; Rengan, R; Zeng, J; Saini, J; Wong, T

    2016-01-01

    Purpose: NSCLC patient RT is planned without consideration of spatial heterogeneity in lung function or tumor response, which may have contributed to failed uniform dose escalation in a randomized trial. The feasibility of functional lung avoidance and response-adaptive escalation (FLARE) RT to reduce dose to ["9"9"mTc]MAA-SPECT/CT perfused lung while redistributing 74Gy within ["1"8F]FDG-PET/CT biological target volumes was assessed. Methods: Eight Stage IIB–IIIB NSCLC patients underwent FDG-PET/CT and MAA-SPECT/CT treatment planning scans. Perfused lung objectives were derived from scatter/collimator/attenuation-corrected MAA-SPECT uptake relative to ITV-subtracted lung to maintain <20Gy mean lung dose (MLD). Prescriptions included 60Gy to PTV and concomitant boost of 74Gy mean to biological target volumes (BTV=GTV+PET margin) scaled to each BTV voxel by relative FDG-PET SUV. Dose-painting-by-numbers prescriptions were integrated into commercial TPS via previously reported ROI discretization. Dose constraints for lung, heart, cord, and esophagus were defined. FLARE RT plans were optimized with VMAT, proton pencil beam scanning (PBS) with 3%-3mm robust optimization, and combination PBS (avoidance) plus VMAT (escalation). Dosimetric differences were evaluated by Friedman non-parametric paired test with multiple sampling correction. Results: PTV and normal tissue objectives were not violated in 24 FLARE RT plans. Population median of mean BTV dose was 73.7Gy (68.5–75.5Gy), mean FDG-PET peak dose was 89.7Gy (73.5–103Gy), MLD was 12.3Gy (7.5–19.6Gy), and perfused MLD was 4.8Gy (0.9–12.1Gy). VMAT achieved higher dose to the FDG-PET peak subvolume (p=0.01), while PBS delivered lower dose to lung (p<0.001). Voxelwise linear correlation between BTV dose and FDG-PET uptake was higher for VMAT (R=0.93) and PBS+VMAT (R=0.94) compared to PBS alone (R=0.89). Conclusion: FLARE RT is feasible with VMAT and PBS. A combination of PBS for functional lung avoidance and

  7. SU-D-202-01: Functional Lung Avoidance and Response-Adaptive Escalation (FLARE) RT: Feasibility of a Precision Radiation Oncology Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, S; Lee, E; Miyaoka, R; Kinahan, P; Sandison, G; Vesselle, H; Rengan, R; Zeng, J [University of Washington, School of Medicine, Seattle, WA (United States); Saini, J; Wong, T [SCCA Proton Therapy Center, Seattle, WA (United States)

    2016-06-15

    Purpose: NSCLC patient RT is planned without consideration of spatial heterogeneity in lung function or tumor response, which may have contributed to failed uniform dose escalation in a randomized trial. The feasibility of functional lung avoidance and response-adaptive escalation (FLARE) RT to reduce dose to [{sup 99m}Tc]MAA-SPECT/CT perfused lung while redistributing 74Gy within [{sup 18}F]FDG-PET/CT biological target volumes was assessed. Methods: Eight Stage IIB–IIIB NSCLC patients underwent FDG-PET/CT and MAA-SPECT/CT treatment planning scans. Perfused lung objectives were derived from scatter/collimator/attenuation-corrected MAA-SPECT uptake relative to ITV-subtracted lung to maintain <20Gy mean lung dose (MLD). Prescriptions included 60Gy to PTV and concomitant boost of 74Gy mean to biological target volumes (BTV=GTV+PET margin) scaled to each BTV voxel by relative FDG-PET SUV. Dose-painting-by-numbers prescriptions were integrated into commercial TPS via previously reported ROI discretization. Dose constraints for lung, heart, cord, and esophagus were defined. FLARE RT plans were optimized with VMAT, proton pencil beam scanning (PBS) with 3%-3mm robust optimization, and combination PBS (avoidance) plus VMAT (escalation). Dosimetric differences were evaluated by Friedman non-parametric paired test with multiple sampling correction. Results: PTV and normal tissue objectives were not violated in 24 FLARE RT plans. Population median of mean BTV dose was 73.7Gy (68.5–75.5Gy), mean FDG-PET peak dose was 89.7Gy (73.5–103Gy), MLD was 12.3Gy (7.5–19.6Gy), and perfused MLD was 4.8Gy (0.9–12.1Gy). VMAT achieved higher dose to the FDG-PET peak subvolume (p=0.01), while PBS delivered lower dose to lung (p<0.001). Voxelwise linear correlation between BTV dose and FDG-PET uptake was higher for VMAT (R=0.93) and PBS+VMAT (R=0.94) compared to PBS alone (R=0.89). Conclusion: FLARE RT is feasible with VMAT and PBS. A combination of PBS for functional lung avoidance

  8. Single photon emission computed tomography (SPECT) in neurocysticercosis

    International Nuclear Information System (INIS)

    Braga, Francisco Jose H. N; Santos, Antonio C; Takanayagui, Oswaldo M; Agapejev, Svetlana; Maes, A

    2002-01-01

    Neurocysticercosis (NC) is a parasitic infectious disease caused by Taenia solium eggs that set in the brain. Its incidence is increasing both in the developing and the developed world, as a result of low economical and hygiene levels and immigration, respectively. Clinical manifestation of disease varies from no symptoms to epilepsy, increased intra-cranial pressure, arachnoiditis and dementia. In order to evaluate function (perfusion) of affected brains, we studied 40 patients (21 females and 19 males, 19-71 yo) by means of SPECT (ECD, ethyl cysteinate dimer, labelled with 99mTc) and with and without contrast CT. SPECT studies were all abnormal. No difference was noted between active and inactive disease. Two SPECT patterns were noted: a) several areas of focally reduced uptake, resulting from coalescent and big lesions and large destruction of brain tissue (small, isolated and symmetric cysts seen in CT were missed by SPECT); b) diffuse atrophy with reduction of the tracer uptake, associated with ventricle dilatation, corresponding to the cases where ventricular NC was important. Interestingly, we noted diffuse hypoperfusion, with the scintigraphic pattern of atrophy in 5 cases of massive parenchymal infection; in such cases, CT signs of atrophy were clearly less prominent. The first scintigraphic aspect can be explained by the destruction of large areas of brain, which produces focal absence of perfusion; generalised vasculitis and the destruction of large portions of brain tissue could explain the difference noted between the SPECT and the CT aspects in the 5 cases of massive parenchimal infection, and this may be interesting for prognosis. Dilatation of ventricles and Sylvian fissures were interestingly prominent in SPECT. SPECT may be of great value to evaluate brain perfusion in NC (Au)

  9. Tc-99m Ciprofloxacin SPECT of Pulmonary Tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kyung; Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Yoon, Min Ki [Good Samaritan Hospital, Pohang (Korea, Republic of); Choe, Won Sick [Kangbuk Samsung Hospital, Seoul (Korea, Republic of)

    2010-06-15

    Tc-99m ciprofloxacin is available for imaging infection. However, there has been no study on employing single photon emission computed tomography (SPECT) with using Tc-99m ciprofloxacin to image active pulmonary tuberculosis. Therefore, we conducted this study to assess the efficacy of Tc-99m ciprofloxacin SPECT for imaging active pulmonary tuberculosis. Twenty-one participants were enrolled in this prospective study. They were divided into two groups according to the clinical and radiological assessment. Group one (Gr. 1) consisted of five normal volunteers and six patients with inactive pulmonary tuberculosis. Group two (Gr. 2) consisted of ten patients with active pulmonary tuberculosis. SPECT was performed 3 h after injecting 555 MBq (15 mCi) of Tc-99m ciprofloxacin. The findings of Tc-99m ciprofloxacin SPECT were interpreted by a nuclear medicine specialist and then the results were analyzed according to the patients' clinical and radiological classifications. The results of Tc-99m ciprofloxacin SPECT were as follows: eight true-positive cases, ten true-negative cases, one false-positive case and two false-negative cases. The sensitivity and specificity was 80.0% and 90.0%, respectively. The positive predictive value was 88.9% and the negative predictive value was 83.3%. Conclusions Tc-99m ciprofloxacin SPECT is feasible for imaging active pulmonary tuberculosis. It is a useful nuclear-imaging method for discriminating between the active and inactive tuberculosis states in patients with a past medical history of pulmonary tuberculosis.

  10. Brain SPECT using dipyridamole for evaluation of vascular reserve

    International Nuclear Information System (INIS)

    Kim, Su Zy; Park, Chan Hee; Yoon, Soo Hwan; Pai, Moon Sun; Yoon, Suk Nam; Cho, Kyung Kee

    1997-01-01

    Baseline and stress brain SPECT studies using CO 2 inhalation, acetazolamide (Diamox R ) and adenosine administrations have been used in the evaluation of cerebral vascular reserve. Recently dipyridamole (Persantine R ) which is one of the pharmacologic myocardial perfusion SPECT agents as a potent vasodilator is suggested as another cerebral vasodilator. IV Diamox R is not available in Korea. Therefore, the purpose of our study was to evaluate dipyridamole in stress brain SPECT in patients with Moya Moya disease. Eight patients with angiographically proven Moya Moya disease were studied. Their ages ranged from 7 to 62 year old. There were 4 males and 4 females. Each patient had a baseline and persantine brain SPECT studies with 1 to 3 days' interval. Dipyridamole was given intravenously at a dose of 0.56 mg/kg over 4 minutes while watching vital signs such as blood pressure, heart rate, and electrocardiogram. Three minutes after the completion of the infusion, 99mTc-ECD (0.2 mCi/Ib body weight) was injected. Brain SPECT was performed 30 minutes later using a tripple head gamma camera equipped with LEHR collimators. A total of 128 projections with an acquisition time of 30 second per projection was obtained and reconstructed by filtered back projections without attenuation correction. The difference between the baseline and persantine studies was analysed by visual and semiquantitavely. During the infusion of persantine, heart rate, blood pressure and side effects such as headache, chest discomfort were similar to the persantine myocardial SPECT studies. Five of eight patients showed a significant decrease in rCBF on persantine brain SPECT in comparison to the baseline study. The remaining three revealed no significant change in rCBF. Our study suggests that the dipyridamole stress brain SPECT is feasible and useful in assessing cerebral blood flow reserve. However we need to evaluate more number of patients in the future

  11. Usefulness of isoproterenol stress thallium-201 myocardial single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi

    1990-01-01

    Twenty patients complaining of chest pain were referred for isoproterenol stress thallium-201 myocardial single photon emission computed tomography (ISO-SPECT). The findings were compared with those obtained from isoproterenol stress ECG testing (ISO-ECG) and exercise SPECT (EX-SPECT). Isoproterenol was iv injected in a dose of 0.02 μg/kg/min. The amount was continuously increased until limited by chest pain, ST depression, and/or determined heart rate criteria. The patients were scanned immediately and three hours after giving isoproterenol. Transient hypoperfusion was regarded as myocardial ischemia. Washout rate, obtained from circumferential profile analysis on the short axis SPECT images, was expressed by Bull's eye display. Fifteen patients with angiographically significant stenosis of 75% or greater were diagnosed as having coronary artery disease (CAD). The other five patients had normal coronary artery (NC). In diagnosing CAD, ISO-ECG and ISO-SPECT had a sensitivity of 80% and 92%, respectively. Because the NC group had negative findings for redistribution on ISO-SPECT, the specificy of ISO-SPECT seemed to be high. For multi-vessel disease, redistribution on ISO-SPECT tended to underestimate coronary lesions. The underestimation was, however, corrected by calculating washout rate. For evaluable 11 patients undergoing concurrent EX-SPECT, ISP-SPECT was equivalent or superior to EX-SPECT in diagnostic sensitivity. None of the patients had severe side effects of isoproterenol, except for some having arrhythmia. The results indicated that ISO-SPECT is a safe, high sensitive diagnostic approach that is comparable to Ex-SPECT. (N.K.)

  12. SPECT/CT in the Diagnosis of Skull Base Osteomyelitis

    International Nuclear Information System (INIS)

    Damle, Nishikant Avinash; Kumar, Rakesh; Kumar, Praveen; Jaganthan, Sriram; Patnecha, Manish; Bal, Chandrasekhar; Bandopadhyaya, Gurupad; Malhotra, Arun

    2011-01-01

    Skull base osteomyelitis is a potentially fatal disease. We demonstrate here the utility of SPECT/CT in diagnosing this entity, which was not obvious on a planar bone scan. A 99mT c MDP bone scan with SPECT/CT was carried out on a patient with clinically suspected skull base osteomyelitis. Findings were correlated with contrast enhanced CT (CECT) and MRI. Planar images were equivocal, but SPECT/CT showed intense uptake in the body of sphenoid and petrous temporal bone as well as the atlas corresponding to irregular bone destruction on CT and MRI. These findings indicate that SPECT/CT may have an additional role beyond planar imaging in the detection of skull base osteomyelitis.

  13. [sup 99m]Tc-ECD SPECT study in dementia and aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1993-09-01

    We studied clinical significance of [sup 99m]Tc-L,L,-ethyl cysteine dimer ([sup 99m]Tc-ECD) SPECT study in dementia and aphasia, and compared it with [sup 99m]Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in [sup 99m]Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in [sup 99m]Tc-HMPAO SPECT. The count rate ratios in [sup 99m]Tc-ECD and [sup 99m]Tc-HMPAO SPECT were correlated well with each other, and the contrast of the [sup 99m]Tc-ECD SPECT image was equivalent or slightly higher as compared with [sup 99m]Tc-HMPAO. Therefore, [sup 99m]Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author).

  14. Left ventricular ejection fraction determined by gated Tl-201 perfusion SPECT and quantitative software

    International Nuclear Information System (INIS)

    Hyun, In Young; Kim, Sung Eun; Seo, Jeong Kee; Hong, Eui Soo; Kwan, Jun; Park, Keum Soo; Lee, Woo Hyung

    2000-01-01

    We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT (40%±14%) and GBP scan (43%±14%). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=3D0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2%. Ninety-five percent limits of agreement were ±9.8%. EF between g-Tl-SPECT and GBP scan were in poor agreement. The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.=20

  15. Brain pertechnetate SPECT in perinatal asphyxia

    Energy Technology Data Exchange (ETDEWEB)

    Sfakianakis, G.; Curless, R.; Goldberg, R.; Clarke, L.; Saw, C.; Sfakianakis, E.; Bloom, F.; Bauer, C.; Serafini, A.

    1984-01-01

    Single photon emission computed tomography of the brain was performed in 6 patients with perinatal asphyxis aged 8-26 days. A single-head (LFOV) commercial SPECT system (Picker) was used and data were acquired 2-3 hr after an IV injection of 1-2 mCi Tc-99m-pertechnetate (360/sup 0/ rotation, 60 views, 64 x 64 matrix, 50K cts/view). Reconstruction in three planes was performed using MDS software (Hanning medium resolution filter, with or without attenuation correction using Sorenson's technique). For each clinical study, a ring type phantom source was used to identify the level of reconstruction noise in the tomographic planes. Abnormalities were found in all patients studied, 3 central (moderate intensity), 2 peripheral (1 severe, 1 moderate) and 1 diffuse (mild intensity). Despite use of oral perchlorate (50 mg) in one patient the choroid plexus was visible. Since attenuation correction tended to amplify noise, the clinical studies were interpreted both with and without this correction. All 3 patients with central lesions were found abnormal on early (1-4 mo) neurologic follow-up examination, whereas the others were normal. No correlation was found between SPECT and 24 hr blood levels of CPK, ammonia, base excess, or the Apgar scores. Ct scans were reported abnormal (3 diffuse, 1 peripheral, 1 central and 1 questionable). Planar scintigrams obtained immediately after SPECT were normal (2), questionable (2) and abnormal (2). Follow-up SPECT brain scintigrams in two of the patients showed partial resolution. SPECT of the brain appears promising in perinatal asphyxia but long-term correlation with patient development is necessary.

  16. SPECT/CT imaging in general orthopedic practice.

    Science.gov (United States)

    Scharf, Stephen

    2009-09-01

    The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.

  17. Application of I-123 HIPDM as a lung imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Shih, W J; Coupal, J J; Dillon, M L; Kung, H F

    1988-04-01

    N,N,N'-Trimethyl-N'-(2-Hydroxyl-3-Methyl-5-/sup 123/I Iodobenzyl)-1,3-Propanediamine.Hcl (/sup 123/I-HIPDM) has been used for diagnosis of patients with strokes and demantias. Since this radiopharmaceutical is also accumulated in the lung, we routinely performed a lung image or images immediately prior to cerebral planar and SPECT images after a 3-5 mCi /sup 123/I-HIPDM injection. During the past 14 months, we obtained 78 (age from 41 to 92 years, average 66.7+-8.9 years; 64 males, 14 females) suspected stroke or dementia patients' lung images. All lung images were correlated to chest X-ray (CXR) or CT and other clinical data. Sixty five of 78 patients had normal lungs showing homogeneous distribution of activity throughout the lungs which correlated well to normal CXR and/or CT studies. Abnormal scintigraphic patterns of the 13 patients included lung defect (5 bronchogenic carcinoma with or without atelectasis) and decreased uptake in apices (8 chronic obstructive pulmonary disease). The findings of pulmonary intrathoracic pathologies on lung images with /sup 123/I-HIPDM suggests further evaluation of the agent for detection of localized pulmonary diseases and pulmonary physiological studies relating to amine metabolism.

  18. Femoral chondrosarcoma discovered by SPECT-T.D.M. osseous scintigraphy; Chondrosarcome femoral decouvert par scintigraphie osseuse SPECT-TDM

    Energy Technology Data Exchange (ETDEWEB)

    Bourahla, K.; Nguyen, L.; Rolling, P.; Schott, A.; Di Salvo, R. [CLCC Paul-Strauss, Strasbourg, (France)

    2009-05-15

    Objectives: the SPECT/T.D.M. imaging can allow a quick diagnosis direction by the concomitant exploitation of scintigraphy data and morphological data brought by the T.D.M.. We present the case of a chondrosarcoma diagnosed in nuclear medicine thanks to the exploitation of the data supplied by the SPECT/T.D.M. that allowed to direct rapidly the later explorations while reducing the time of the patient coverage. Conclusions: A knowledge of the most characteristic morphological data allows to give some diagnosis at first sight during the scintigraphy explorations coupled SPECT/T.D.M. and this in the interest of the patient by reducing his coverage while including the nuclear doctor more broadly in some diagnosis approaches previously remote from his reach. (N.C.)

  19. Usefulness of hyperventilation myocardial SPECT for diagnosing vasospastic angina pectoris

    International Nuclear Information System (INIS)

    Tahara, Yorio; Shimoyama, Katsuya; Nishimura, Tooru; Sasaki, Akira; Taya, Makoto; Mizuno, Haruyoshi; Ono, Akifumi; Tsuya, Tsuneo; Ishikawa, Kyozo

    1990-01-01

    We evaluated the usefulness of hyperventilation myocardial scintigraphy (HV-SPECT) for diagnosing vasospastic angina pectoris. The subjects consisted of 11 patients with rest angina and 13 with rest and exertional angina in whom coronary spasm was demonstrated by coronary angiography, and 6 with exertional angina in whom a significant stenotic lesion was observed by coronary angiography. Hyperventilation was performed at a rate of 40/min for 5 minutes in all the patients. Ischemia was considered to be present when defect and redistribution were observed by SPECT. HV-SPECT revealed positive findings in 8 patients with rest angina (73%) and 9 with exertional and rest angina (69%) but only in 1 with exertional angina (17%). Ischemic ST changes on monitor ECG were observed in 13 of the 30 patients (43%); ST was enhanced in 4 patients and depressed in 9 patients. In the patients with rest angina, HV-SPECT induced ischemic findings more frequently than exercise SPECT (73% vs 55%). HV-SPECT seems to be useful as a non-invasive method for diagnosing angina pectoris resulting from coronary spasm. (author)

  20. Intra-image referencing for simplified assessment of HER2-expression in breast cancer metastases using the Affibody molecule ABY-025 with PET and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sandberg, Dan; Tolmachev, Vladimir; Olofsson, Helena; Carlsson, Joergen; Lindman, Henrik [Uppsala University, Department of Immunology, Genetics and Pathology, Uppsala (Sweden); Velikyan, Irina; Soerensen, Jens [Uppsala University, Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala (Sweden); Wennborg, Anders; Feldwisch, Joachim [Affibody AB, Solna (Sweden)

    2017-08-15

    In phase I/II-studies radiolabelled ABY-025 Affibody molecules identified human epidermal growth factor receptor 2 (HER2) expression in breast cancer metastases using PET and SPECT imaging. Here, we wanted to investigate the utility of a simple intra-image normalization using tumour-to-reference tissue-ratio (T/R) as a HER2 status discrimination strategy to overcome potential issues related to cross-calibration of scanning devices. Twenty-three women with pre-diagnosed HER2-positive/negative metastasized breast cancer were scanned with [{sup 111}In]-ABY-025 SPECT/CT (n = 7) or [{sup 68}Ga]-ABY-025 PET/CT (n = 16). Uptake was measured in all metastases and in normal spleen, lung, liver, muscle, and blood pool. Normal tissue uptake variation and T/R-ratios were established for various time points and for two different doses of injected peptide from a total of 94 whole-body image acquisitions. Immunohistochemistry (IHC) was used to verify HER2 expression in 28 biopsied metastases. T/R-ratios were compared to IHC findings to establish the best reference tissue for each modality and each imaging time-point. The impact of shed HER2 in serum was investigated. Spleen was the best reference tissue across modalities, followed by blood pool and lung. Spleen-T/R was highly correlated to PET SUV in metastases after 2 h (r = 0.96,P < 0.001) and reached an accuracy of 100% for discriminating IHC HER2-positive and negative metastases at 4 h (PET) and 24 h (SPECT) after injection. In a single case, shed HER2 resulted in intense tracer retention in blood. In the remaining patients shed HER2 was elevated, but without significant impact on ABY-025 biodistribution. T/R-ratios using spleen as reference tissue accurately quantify HER2 expression with radiolabelled ABY-025 imaging in breast cancer metastases with SPECT and PET. Tracer binding to shed HER2 in serum might affect quantification in the extreme case. (orig.)

  1. Clinical utility of ultrasound and 99mTc sestamibi SPECT/CT for preoperative localization of parathyroid adenoma in patients with primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Patel, C.N.; Salahudeen, H.M.; Lansdown, M.; Scarsbrook, A.F.

    2010-01-01

    Aim: To evaluate the accuracy of ultrasound and parathyroid scintigraphy using single photon-emission computed tomography/computed tomography (SPECT/CT) for the preoperative localization of solitary parathyroid adenomas in patients with primary hyperparathyroidism who would be suitable for minimally invasive parathyroid surgery. Materials and methods: Retrospective study of 63 consecutive patients with biochemical evidence of primary hyperparathyroidism referred for preoperative localization of parathyroid adenoma that proceeded to surgery in the same institution. All patients underwent high-resolution ultrasound and Technetium-99m sestamibi scintigraphy with planar and SPECT/CT imaging. The accuracy of preoperative imaging was compared to surgical and histological findings as the reference standard. Results: Fifty-nine patients had solitary parathyroid adenomas, three patients had multiglandular hyperplasia, and one patient had multiple parathyroid adenomas confirmed at surgery and histology. Thirty-five solitary parathyroid adenomas were identified preoperatively with ultrasound (64%) and 53 with SPECT-CT (90%). Concordant ultrasound and SPECT/CT findings were found in 35 cases (59%). An additional three adenomas were found with ultrasound alone and 18 adenomas with SPECT/CT alone. Fifty-one of the 56 adenomas localized using combined ultrasound and SPECT/CT were found at the expected sites during surgery. Combined ultrasound and SPECT/CT has an overall sensitivity of 95% and accuracy of 91% for the preoperative localization of solitary parathyroid adenomas. Conclusions: The combination of ultrasound and SPECT/CT has incremental value in accurately localizing solitary parathyroid adenomas over either technique alone, and allows selection of patients with primary hyperparathyroidism who would be suitable for minimally invasive surgery.

  2. [Myokard-Perfusions-SPECT. Myocardial perfusion SPECT - Update S1 guideline].

    Science.gov (United States)

    Lindner, Oliver; Bengel, Frank; Burchert, Wolfgang; Dörr, Rolf; Hacker, Marcus; Schäfer, Wolfgang; Schäfers, Michael A; Schmidt, Matthias; Schwaiger, Markus; Vom Dahl, Jürgen; Zimmermann, Rainer

    2017-08-14

    The S1 guideline for myocardial perfusion SPECT has been published by the Association of the Scientific Medical Societies in Germany (AWMF) and is valid until 2/2022. This paper is a short summary with comments on all chapters and subchapters wich were modified and amended.

  3. SPECT of aged backache patients

    International Nuclear Information System (INIS)

    Ito, Shigehiko; Nishikimi, Junzo; Mizuno, Naokado; Watanabe, Kentaro; Kondo, Masaki; Ozaki, Satoshi; Urasaki, Tetsuya; Muro, Toshiyuki

    1995-01-01

    Single photon emission computed tomography (SPECT) using 99m Tc-HMDP was performed on 53 middle-aged or elderly patients (male 20, female, 33; age range, 40-80 years old) with lumbago, i.e., 25 patients with lumbar spondylosis, 15 with lumbar degenerative spondylolisthesis, 4 with spondylolytic spondylolisthesis, 3 with compression fracture, 3 with pulurent spondylitis, 2 with spondylous osteoporosis, and 1 with spinal osteodesmosis. 99m Tc-HMDP (740 MBq) was intravenously injected and regular SPECT was performed at 3 hours. Gamma camera was performed for about 10 seconds with 5deg intervals, and 36 steps (180deg) of collection was completed after about 6 minutes. The radioisotope accumulation, the presence or absence of sthenia, and its site were evaluated. Forty-seven (88.7%) patients showed excessive accumulation, i.e., 40 (75.5%) in peripheral vertebral osteophyte, 31 (58.5%) in vertebral articulations, and 10 (18.9%) in whole vertebral body. Significantly increased bilateral excessive accumulation was admitted in the vertebral articulations of sliding disc in degenerative spondylolisthesis. SPECT is considered useful in understanding the pathophysiology of degenerative lumber diseases. (S.Y.)

  4. Labeled receptor ligands for spect

    International Nuclear Information System (INIS)

    Kung, H.F.

    1989-01-01

    Receptor specific imaging agents for single photon emission computed tomography (SPECT) can potentially be useful in the understanding of basic biochemistry and pharmacology of receptors. SPECT images may also provide tools for evaluation of density and binding kinetics of a specific receptor, information important for diagnosis and patient management. Basic requirements for receptor imaging agents are: (a) they are labeled with short-lived isotopes, (b) they show high selectivity and specific uptake, (c) they exhibit high target/background ratio, and (d) they can be modeled to obtain quantitative information. Several good examples of CNS receptor specific ligands labeled with I-123 have been developed, including iodoQNB, iodoestrogen iodobenzadiazepine, iodobenazepine, iodobenzamides for muscarinic, estrogen benzadiazepine, D-1 and D-2 dopamine receptors. With the advent of newer and faster SPECT imaging devices, it may be feasible to quantitate the receptor density by in vivo imaging techniques. These new brain imaging agents can provide unique diagnostic information, which may not be available through other imaging modalities, such as CT and MRI

  5. Clinical applications of SPECT/CT: New hybrid nuclear medicine imaging system

    International Nuclear Information System (INIS)

    2008-08-01

    Interest in multimodality imaging shows no sign of subsiding. New tracers are spreading out the spectrum of clinical applications and innovative technological solutions are preparing the way for yet more modality marriages: hybrid imaging. Single photon emission computed tomography (SPECT) has enabled the evaluation of disease processes based on functional and metabolic information of organs and cells. Integration of X ray computed tomography (CT) into SPECT has recently emerged as a brilliant diagnostic tool in medical imaging, where anatomical details may delineate functional and metabolic information. SPECT/CT has proven to be valuable in oncology. For example, in the case of a patient with metastatic thyroid cancer, neither SPECT nor CT alone could identify the site of malignancy. SPECT/CT, a hybrid image, precisely identified where the surgeon should operate. However SPECT/CT is not just advantageous in oncology. It may also be used as a one-stop-shop for various diseases. Clinical applications with SPECT/CT have started and expanded in developed countries. It has been reported that moving from SPECT alone to SPECT/CT could change diagnoses in 30% of cases. Large numbers of people could therefore benefit from this shift all over the world. This report presents an overview of clinical applications of SPECT/CT and a relevant source of information for nuclear medicine physicians, radiologists and clinical practitioners. This information may also be useful for decision making when allocating resources dedicated to the health care system, a critical issue that is especially important for the development of nuclear medicine in developing countries. In this regard, the IAEA may be heavily involved in the promotion of programmes aimed at the IAEA's coordinated research projects and Technical Cooperation projects

  6. 99mTc-HMPAO SPECT in pediatric patients with neurological disorders

    International Nuclear Information System (INIS)

    Yamaoka, Mitsuko

    1994-01-01

    In 125 pediatric patients with suspected brain diseases, EEG, CT and MRI findings were compared with those obtained with single photon emission computed tomography (SPECT) of the brain using Tc-99m-d, 1-hexamethyl-propylene amine oxime ( 99m Tc-HMPAO), to determine the usefulness of SPECT as an adjunct to EEG, CT and MRI in this age group. The incidences of abnormal finding in the 125 patients were 53.6, 75.2, 60.6 and 51.4% using 99m Tc-HMPAO SPECT, EEG, CT and MRI respectively. In localization-related epilepsy and cerebrovascular diseases, the incidence of abnormality was higher with 99m Tc-HMPAO SPECT than with either CT or MRI. There was a tendency for mean age to be higher and mean IQ or DG lower in patients with more extensive abnormality in comparison to those who had normal or only focally abnormal SPECT findings. Nevertheless, some patients showed focal hypofusion in the frontal or occipital area without significant mental retardation. Epileptic foci detected by EEG corresponded to defects found using 99m Tc-HMPAO SPECT in 34.8% of the symptomatic localization-related epileptic patients. Pathological lesions detected by CT or MRI corresponded with SPECT findings in 48.1% of patients. Furthermore, the incidence of abnormal findings on SPECT was 30% in patients in whom CT or MRI was normal. Epileptic foci detected by EEG did not correspond well with the area of focal hyperfusion found on SPECT. Focal hyperfusion may sometimes occur even in the interictal period or postictal period in childhood seizure disorders. In conclusion, 99m Tc-HMPAO SPECT revealed abnormal findings at a moderate incidence in neuropediatric patients. Correlations with EEG, CT and MRI findings as well as assessment of clinical signs, including the investigation of epileptic foci, are essential for adequate interpretation of brain functions. (author)

  7. WE-AB-202-05: Validation of Lung Stress Maps for CT-Ventilation Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cazoulat, G; Jolly, S; Matuszak, M; Balter, J; Brock, K [University of Michigan, Ann Arbor, MI (United States); Kipritidis, J; Keall, P [University of Sydney, Sydney NSW (Australia); Siva, S; Hofman, M [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne VIC (Australia)

    2016-06-15

    Purpose: To date, lung CT-ventilation imaging has been based on quantification of local breathing-induced changes in Hounsfield Units (HU) or volume. This work investigates the use of a stress map resulting from a biomechanical deformable image registration (DIR) algorithm as a metric of the ventilation function. Method: Eight lung cancer patients presenting different kinds of ventilation defects were retrospectively analyzed. Additionally, to the 4DCT acquired for radiotherapy planning, five of them had PET and three had SPECT imaging following inhalation of Ga-68 and Tc-99m, respectively. For each patient, the inhale phase of the 4DCT was registered to the exhale phase using Morfeus, a biomechanical DIR algorithm based on the determination of boundary conditions on the lung surfaces and vessel tree. To take into account the heterogeneity of the tissue stiffness in the stress map estimation, each tetrahedral element of the finite-element model was assigned a Young’s modulus ranging from 60kPa to 12MPa, as a function of the HU in the inhale CT. The node displacements and element stresses resulting from the numerical simulation were used to generate three CT-ventilation maps based on: (i) volume changes (Jacobian determinant), (ii) changes in HU, (iii) the maximum principal stress. The voxel-wise correlation between each CT-ventilation map and the PET or SPECT V image was computed in a lung mask. Results: For patients with PET, the mean (min-max) Spearman correlation coefficients r were: 0.33 (0.19–0.45), 0.36 (0.16–0.51) and 0.42 (0.21–0.59) considering the Jacobian, changes in HU and maximum principal stress, respectively. For patients with SPECT V, the mean r were: 0.12 (−0.12–0.43), 0.29 (0.22–0.45) and 0.33 (0.25–0.39). Conclusion: The maximum principal stress maps showed a stronger correlation with the ventilation images than the previously proposed Jacobian or change in HU maps. This metric thus appears promising for CT-ventilation imaging

  8. Implementation of angular response function modeling in SPECT simulations with GATE

    International Nuclear Information System (INIS)

    Descourt, P; Visvikis, D; Carlier, T; Bardies, M; Du, Y; Song, X; Frey, E C; Tsui, B M W; Buvat, I

    2010-01-01

    Among Monte Carlo simulation codes in medical imaging, the GATE simulation platform is widely used today given its flexibility and accuracy, despite long run times, which in SPECT simulations are mostly spent in tracking photons through the collimators. In this work, a tabulated model of the collimator/detector response was implemented within the GATE framework to significantly reduce the simulation times in SPECT. This implementation uses the angular response function (ARF) model. The performance of the implemented ARF approach has been compared to standard SPECT GATE simulations in terms of the ARF tables' accuracy, overall SPECT system performance and run times. Considering the simulation of the Siemens Symbia T SPECT system using high-energy collimators, differences of less than 1% were measured between the ARF-based and the standard GATE-based simulations, while considering the same noise level in the projections, acceleration factors of up to 180 were obtained when simulating a planar 364 keV source seen with the same SPECT system. The ARF-based and the standard GATE simulation results also agreed very well when considering a four-head SPECT simulation of a realistic Jaszczak phantom filled with iodine-131, with a resulting acceleration factor of 100. In conclusion, the implementation of an ARF-based model of collimator/detector response for SPECT simulations within GATE significantly reduces the simulation run times without compromising accuracy. (note)

  9. Implementation of angular response function modeling in SPECT simulations with GATE

    Energy Technology Data Exchange (ETDEWEB)

    Descourt, P; Visvikis, D [INSERM, U650, LaTIM, IFR SclnBioS, Universite de Brest, CHU Brest, Brest, F-29200 (France); Carlier, T; Bardies, M [CRCNA INSERM U892, Nantes (France); Du, Y; Song, X; Frey, E C; Tsui, B M W [Department of Radiology, J Hopkins University, Baltimore, MD (United States); Buvat, I, E-mail: dimitris@univ-brest.f [IMNC-UMR 8165 CNRS Universites Paris 7 et Paris 11, Orsay (France)

    2010-05-07

    Among Monte Carlo simulation codes in medical imaging, the GATE simulation platform is widely used today given its flexibility and accuracy, despite long run times, which in SPECT simulations are mostly spent in tracking photons through the collimators. In this work, a tabulated model of the collimator/detector response was implemented within the GATE framework to significantly reduce the simulation times in SPECT. This implementation uses the angular response function (ARF) model. The performance of the implemented ARF approach has been compared to standard SPECT GATE simulations in terms of the ARF tables' accuracy, overall SPECT system performance and run times. Considering the simulation of the Siemens Symbia T SPECT system using high-energy collimators, differences of less than 1% were measured between the ARF-based and the standard GATE-based simulations, while considering the same noise level in the projections, acceleration factors of up to 180 were obtained when simulating a planar 364 keV source seen with the same SPECT system. The ARF-based and the standard GATE simulation results also agreed very well when considering a four-head SPECT simulation of a realistic Jaszczak phantom filled with iodine-131, with a resulting acceleration factor of 100. In conclusion, the implementation of an ARF-based model of collimator/detector response for SPECT simulations within GATE significantly reduces the simulation run times without compromising accuracy. (note)

  10. Brain SPECT in childhood; Temp cerebrale chez l'enfant

    Energy Technology Data Exchange (ETDEWEB)

    Tranquart, F; Saliba, E; Prunier, C; Baulieu, F; Besnard, J C; Guilloteau, D; Baulieu, J L [Hopital Bretonneau, Service de Medecine Nucleaire, Unite Inserm 316, 37 - Tours (France)

    2001-04-01

    The modalities and the indications of perfusion and neurotransmission SPECT in childhood are presented. The perfusion as well as neurotransmission tracers have not yet authorization for use in children; they have to be used by prescription of magistral preparation or in research protocols. The radioprotection rules have to be strictly respected. The most frequent indication of perfusion SPECT is pharmacologically resistant epilepsy; the ictal SPECT before surgery allows the localization of the epileptogenic focus. Other indications are relevant in the prognosis of neonatal anoxia and encephalitis. In psychiatric disorders, especially in autism, the interest is the physiopathological approach of the brain dysfunctions. The neurotransmission SPECT is emerging as a consequence of the development of new radiotracer, as the dopaminergic system ligands. The decrease of the dopamine D2 receptors in the striatum can be imaged and quantified in the neonate. The lesions of dopamine system seem to be a consequence of the neonatal hypoxia-ischemia and it is predictive of motor sequelae. Brain SPECT should become a routine examination in child neurologic and psychiatric disorders. (authors)

  11. Single-Photon Emission Computed Tomography (SPECT) in childhood epilepsy

    International Nuclear Information System (INIS)

    Gulati, Sheffali; Kalra, Veena; Bal, C.S.

    2000-01-01

    The success of epilepsy surgery is determined strongly by the precise location of the epileptogenic focus. The information from clinical electrophysiological data needs to be strengthened by functional neuroimaging techniques. Single photon emission computed tomography (SPECT) available locally has proved useful as a localising investigation. It evaluates the regional cerebral blood flow and the comparison between ictal and interictal blood flow on SPECT has proved to be a sensitive nuclear marker for the site of seizure onset. Many studies justify the utility of SPECT in localising lesions to possess greater precision than interictal scalp EEG or anatomic neuroimaging. SPECT is of definitive value in temporal lobe epilepsy. Its role in extratemporal lobe epilepsy is less clearly defined. It is useful in various other generalized and partial seizure disorders including epileptic syndromes and helps in differentiating pseudoseizures from true seizures. The need for newer radiopharmaceutical agents with specific neurochemical properties and longer shelf life are under investigation. Subtraction ictal SPECT co-registered to MRI is a promising new modality. (author)

  12. 111In-Pentetreotide SPECT/CT in Pulmonary Carcinoid.

    Science.gov (United States)

    Chiaravalloti, Agostino; Spanu, Angela; Danieli, Roberta; Dore, Francesca; Piras, Bastiana; Falchi, Antonio; Tavolozza, Mario; Madeddu, Giuseppe; Schillaci, Orazio

    2015-07-01

    We evaluated somatostatin receptor scintigraphy (SRS) with (111)In-pentetreotide incremental value in pulmonary carcinoid (PC) diagnosis compared to contrast enhanced Computed Tomography (ceCT). We enrolled 81 patients with ascertained PC, 39 at initial staging and 42 in follow-up; the primary tumor had already been excised in 68 cases. Single Photon emission Computed Tomography (SPECT) images were reconstructed with the iterative method and fused with non-enhanced Computed tomography (CT) images. Primary PC or metastatic lesions were ascertained in 55/81 patients and SPECT/CT was positive in 50/55 cases, while ceCT was positive in 44/55. Comparing SPECT/CT with ceCT results, we found a sensitivity of 96 vs. 87.5%, and specificity of 92% vs. 97% for the detection of primary lesion or recurrent disease. A total of 198 lesions were ascertained at SPECT/CT, while 161 at ceCT, with values of sensitivity and specificity of 85.5% and 84.6% for SRS and 75.2% and 90.5% respectively. (111)In-Pentetreotide SPECT/CT proved to be more sensitive and accurate than ceCT, thus enhancing its role in evaluating patients with PC. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  13. Study of regional cerebral blood flow SPECT imaging for sudden sensorineural deafness

    International Nuclear Information System (INIS)

    Xie Changhui; Kui Xixiao; Xiong Qibin; Wen Hui; Xie Jiabiao

    1998-01-01

    Purpose: To study the clinical value of regional cerebral blood flow (rCBF) SPECT imaging for sudden sensorineural deafness (SSD). Methods: 10 normal persons, 19 conductive deafness and 31 SSD patients were examined by rCBF SPECT imaging, and compared with X CT at the same time. All SSD patients were followed up for 6∼12 months with repeated rCBF SPECT imaging. Results: 1) The radioactivity of diseased and normal horizontal temporal gyrus ratio (T/NT) in SSD patients was the lowest among three groups (P < 0.01). 2) The sensitivity (80.6%) and accurate rate (88.3%) of rCBF SPECT imaging in SSD patients were much higher than those of CT (3.2% and 50%, P < 0.01). 3) There was a significant correlation between degree of deafness and T/NT in SSD patients. 4) Good prognosis of SSD patients with normal rCBF SPECT was found. 5) The rCBF SPECT had close concordance between rCBF SPECT imaging and clinical prognosis (84.6%). Conclusions: rCBF SPECT imaging was superior to X CT in diagnosis of SSD and played an important clinical role

  14. Evaluation of role of brain SPECT in diagnosis of post stroke dementia

    International Nuclear Information System (INIS)

    Yousepour, G.; Alavi, M.

    2003-01-01

    Post stroke dementia is one of the most common complications of stroke that is preventable and relatively treatable too. The purpose of the study is comparison between the positive findings in the brain CT scan and brain perfusion SPECT. 15 patients who were complicated by dementia after cerebrovascular accident and also 5 patients as a control group enrolled in this study. Brain CT scan and brain SPECT were performed during at most one week after stroke. Abnormal findings in both brain CT scan and SPECT were seen in 46% of patients. Brain CT scan disclosed more abnormal findings compared to brain SPECT (33.3%). While brain SPECT findings were more information than brain CT scan (20%) this study is indicating that brain CT scan and the brain SPECT concomitantly for each other in better diagnosis of post stroke dementia. We did not find any specific diagnostic pattern in brain SPECT of patients suffering from post stroke dementia. The low quality of brain SPECT in spite of uniformity of gamma camera may be suggestive of low quality of Iran produced ECD kit that needs further evaluation

  15. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  16. Development of advanced industrial SPECT system with 12-gonal diverging-collimator

    International Nuclear Information System (INIS)

    Park, Jang Guen; Jung, Sung-Hee; Kim, Jong Bum; Moon, Jinho; Han, Min Cheol; Kim, Chan Hyeong

    2014-01-01

    Industrial single photon emission computed tomography (SPECT) is a promising diagnosis technique to investigate the dynamic behavior of process media. In the present study, a 12-gonal industrial SPECT system was developed using diverging collimators, and its performance was compared with those of hexagonal and 24-gonal systems. Of all of the systems, the 12-gonal type showed the best performance, providing (1) a detection-efficiency map without edge artifacts, (2) the best image resolution, and (3) reconstruction images that correctly furnish multi-source information. Based on the performance of the three different types of configurations, a SPECT system with 12-gonal type configuration was found most suitable for investigating and visualization of flow dynamics in industrial process systems. - highlights: • Industrial SPECT provides the dynamic behavior of multiphase industrial processes. • The present study compared performance of various industrial SPECT systems. • The 12-gonal SPECT system with diverging-collimator provides the best performance

  17. Study of cerebrovascular diseases and SPECT with 99mTc HMPAO

    International Nuclear Information System (INIS)

    Collazo de la Maza, A.; Borron Molinos, M.; Barroso, E.

    1997-01-01

    Thirty eight patients with Cerebrovascular disease, that had suffered a Thrombotic brain infraction, demonstrated by Computed electroencephalogram or Brain Mapping (BM) and Computerized Tomography (CT) were investigated with '99' '9' 'm' Tc HM-PAO brain SPECT. Their ages ranged from 37 to 73 years old, 18 males and 20 female. Some of them were followed up with these diagnostic methods. The acquisition and processing of the SPECT studies were donw with a SOPHY DS7 Gamma Camera. The results showed that the global diagnostic sensibility of the SPECT was 79%. The sensibility of SPECT in the Acute stage was 75 %, CT 57% and BM 92%. In Steady stage we found a high positivity of SPECT with 83 %, Ct 66% and BM 66%. In the Recuperation Stage SPECT was 77%, CT 66% and 45%. Some phenomenon like the Luxury Perfusion and Diaschisis were studied and it is possible to found some prognostic relation

  18. Preclinical imaging characteristics and quantification of Platinum-195m SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Aalbersberg, E.A.; Wit-van der Veen, B.J. de; Vegt, E.; Vogel, Wouter V. [The Netherlands Cancer Institute (NKI-AVL), Department of Nuclear Medicine, Amsterdam (Netherlands); Zwaagstra, O.; Codee-van der Schilden, K. [Nuclear Research and Consultancy Group (NRG), Petten (Netherlands)

    2017-08-15

    In vivo biodistribution imaging of platinum-based compounds may allow better patient selection for treatment with chemo(radio)therapy. Radiolabeling with Platinum-195m ({sup 195m}Pt) allows SPECT imaging, without altering the chemical structure or biological activity of the compound. We have assessed the feasibility of {sup 195m}Pt SPECT imaging in mice, with the aim to determine the image quality and accuracy of quantification for current preclinical imaging equipment. Enriched (>96%) {sup 194}Pt was irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands (NRG). A 0.05 M HCl {sup 195m}Pt-solution with a specific activity of 33 MBq/mg was obtained. Image quality was assessed for the NanoSPECT/CT (Bioscan Inc., Washington DC, USA) and U-SPECT{sup +}/CT (MILabs BV, Utrecht, the Netherlands) scanners. A radioactivity-filled rod phantom (rod diameter 0.85-1.7 mm) filled with 1 MBq {sup 195m}Pt was scanned with different acquisition durations (10-120 min). Four healthy mice were injected intravenously with 3-4 MBq {sup 195m}Pt. Mouse images were acquired with the NanoSPECT for 120 min at 0, 2, 4, or 24 h after injection. Organs were delineated to quantify {sup 195m}Pt concentrations. Immediately after scanning, the mice were sacrificed, and the platinum concentration was determined in organs using a gamma counter and graphite furnace - atomic absorption spectroscopy (GF-AAS) as reference standards. A 30-min acquisition of the phantom provided visually adequate image quality for both scanners. The smallest visible rods were 0.95 mm in diameter on the NanoSPECT and 0.85 mm in diameter on the U-SPECT{sup +}. The image quality in mice was visually adequate. Uptake was seen in the kidneys with excretion to the bladder, and in the liver, blood, and intestine. No uptake was seen in the brain. The Spearman correlation between SPECT and gamma counter was 0.92, between SPECT and GF-AAS it was 0.84, and between GF-AAS and gamma counter it was0.97 (all p < 0

  19. Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom

    International Nuclear Information System (INIS)

    Akamatsu, Mana; Yamashita, Yasuo; Akamatsu, Go; Tsutsui, Yuji; Ohya, Nobuyoshi; Nakamura, Yasuhiko; Sasaki, Masayuki

    2014-01-01

    The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123 I brain SPECT obtained by the hybrid SPECT/CT device. We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray matter, white matter and bone regions. It was filled with 123 I solution (20.1 kBq/mL) in the gray matter region and with K 2 HPO 4 in the bone region. The SPECT/CT data were acquired by the hybrid SPECT/CT device. SPECT images were reconstructed by using filtered back projection with uniform attenuation correction (FBP-uAC), 3D ordered-subsets expectation-maximization with uniform AC (3D-OSEM-uAC) and 3D OSEM with CT-based non-uniform AC (3D-OSEM-CTAC). We evaluated the differences in the radioactivity distributions among these reconstruction methods using a 3D digital phantom, which was developed from CT images of the 3D brain phantom, as a reference. The normalized mean square error (NMSE) and regional radioactivity were calculated to evaluate the similarity of SPECT images to the 3D digital phantom. The NMSE values were 0.0811 in FBP-uAC, 0.0914 in 3D-OSEM-uAC and 0.0766 in 3D-OSEM-CTAC. The regional radioactivity of FBP-uAC was 11.5% lower in the middle cerebral artery territory, and that of 3D-OSEM-uAC was 5.8% higher in the anterior cerebral artery territory, compared with the digital phantom. On the other hand, that of 3D-OSEM-CTAC was 1.8% lower in all brain areas. By using the hybrid SPECT/CT device, the brain SPECT reconstructed by 3D-OSEM with CT attenuation correction can provide an accurate assessment of the distribution of brain radioactivity

  20. Fusion of SPECT/TC images: Usefulness and benefits in degenerative spinal cord pathology

    International Nuclear Information System (INIS)

    Ocampo, Monica; Ucros, Gonzalo; Bermudez, Sonia; Morillo, Anibal; Rodriguez, Andres

    2005-01-01

    The objectives are to compare CT and SPECT bone scintigraphy evaluated independently with SPECT-CT fusion images in patients with known degenerative spinal pathology. To demonstrate the clinical usefulness of CT and SPECT fusion images. Materials and methods: Thirty-one patients with suspected degenerative spinal disease were evaluated with thin-slice, non-angled helical CT and bone scintigrams with single photon emission computed tomography (SPECT), both with multiplanar reconstructions within a 24-hour period After independent evaluation by a nuclear medicine specialist and a radiologist, multimodality image fusion software was used to merge the CT and SPECT studies and a final consensus interpretation of the combined images was obtained. Results: Thirty-two SPECT bone scintigraphy images, helical CT studies and SPECT-CT fusion images were obtained for 31 patients with degenerative spinal disease. The results of the bone scintigraphy and CT scans were in agreement in 17 pairs of studies (53.12%). In these studies image fusion did not provide additional information on the location or extension of the lesions. In 11 of the study pairs (34.2%), the information obtained was not in agreement between scintigraphy and CT studies: CT images demonstrated several abnormalities, whereas the SPECT images showed only one dominant lesion, or the SPECT images did not provide enough information for anatomical localization. In these cases image fusion helped establish the precise localization of the most clinically significant lesion, which matched the lesion with the greatest uptake. In 4 studies (12.5%) the CT and SPECT images were not in agreement: CT and SPECT images showed different information (normal scintigraphy, abnormal CT), thus leading to inconclusive fusion images. Conclusion: The use of CT-SPECT fusion images in degenerative spinal disease allows for the integration of anatomic detail with physiologic and functional information. CT-SPECT fusion improves the

  1. Brain lesion analysis using three-dimensional SPECT imaging

    International Nuclear Information System (INIS)

    Shibata, Iekado; Onagi, Atsuo; Kuroki, Takao

    1995-01-01

    A three-headed gamma camera (PRISM 3000) is capable to scan the protocol of early dynamic SPECT and to analyze two radioisotopes at the same time. We have framed three-dimensional brain SPECT images for several brain diseases by using the Application Visualization System (AVS). We carried out volume measurements in brain tumors and/or AVMs by applying this methodology. Thallium-201 and/or 123I-IMP were used for brain SPECT imaging. The dynamic scan protocol was changed in accordance with the given disease. The protocol for brain tumors was derived from a preliminary comparative study with thallium-201 and 123I-IMP that had suggested a disparity in the detection of brain tumors and the differentiation between tumor tissue and normal brain. The three-dimension SPECT image represented the brain tumor or AVM in a striking fashion, and the changes with respect to tumor or AVM after radiosurgery or embolization were understood readily. (author)

  2. Regional cerebral blood flow and metabolism in patients with transient global amnesia. A study using SPECT and 1H-MRS

    International Nuclear Information System (INIS)

    Ishihara, Tetsuya; Hirata, Koichi; Tatsumoto, Muneto; Yamazaki, Kaoru; Sato, Toshihiko.

    1997-01-01

    In 13 patients with transient global amnesia (TGA), we studied the clinical course and changes over time by means of imaging techniques such as SPECT. MRI, and proton MR spectroscopy ( 1 H-MRS). In the case of SPECT, a cerebral blood flow decrease at the time center of the temporal lobe persisted at least for more than one month. In many patients, no abnormal signs were found on MRI. Despite the presence of intracranial impairment of energy metabolism, no evidence of cerebral ischemia was obtained using 1 H-MRS at the acute and subacute stages. There were thus discrepancies between the symptoms and the findings of SPECT as well as the findings of 1 H-MRS. These data suggest that TGA may not necessarily be caused by cerebra1 ischemia. (author)

  3. Usefulness of lung and right ventricular thallium-201 uptake during single photon emission computed tomography in exercise testing of patients with coronary artery disease

    International Nuclear Information System (INIS)

    Matoh, Fumitaka; Tawarahara, Kei; Mikami, Naoshi

    2005-01-01

    Increased pulmonary or right ventricular 201 Tl uptake during the exercise test has been used as a marker of multivessel coronary artery disease. The most useful method for assessing the severity of coronary artery disease was evaluated among conventional evaluation of single photon emission computed tomography (SPECT), measurement of lung to heart uptake ratio (L/H), and right ventricular to left ventricular uptake ratio (RV/LV) on 201 Tl images during exercise testing. Regions-of-interest (4 x 4 pixels) were placed at the lung and the heart, and L/H was defined as mean lung uptake/mean heart uptake. Correspondingly, regions-of-interest (4 x 4 pixels) were placed at the RV and the LV, and RV/LV was defined as maximum RV uptake/maximum LV uptake. L/H and RV/LV on the initial image were analyzed in 216 patients (angiographically normal coronary arteries: 89, single-vessel disease: 82, multivessel disease: 45). The diagnostic value was evaluated using the receiver operating characteristic curve. All methods showed significantly higher values in patients with multivessel disease than in patients with no coronary artery disease or single-vessel disease. L/H was significantly higher in patients with prior myocardial infarction and RV/LV was significantly higher in patients without infarction. The sensitivity of only conventional SPECT evaluation for multivessel coronary artery disease was low (sensitivity 53%, specificity 94%). However, addition of evaluation of L/H and RV/LV to SPECT improved the sensitivity for multivessel coronary artery disease (sensitivity 93%, specificity 49%). The diagnostic sensitivity for multivessel coronary artery disease was improved by adding L/H and RV/LV to conventional evaluation of exercise 201 Tl SPECT. L/H and RV/LV during exercise 201 Tl imaging may provide additional information regarding the severity of coronary artery disease. (author)

  4. Usefulness of change ratio map in 99mTc-HMPAO SPECT with acetazolamide enhancement

    International Nuclear Information System (INIS)

    Yamamoto, Naoyuki

    1996-01-01

    Although a sequential 99m Tc-HMPAO SPECT technique with Diamox test (seq-SPECT) is a simple and time-saving procedure to assess brain perfusion reserve, the influence of the first dose of the tracer on the second one is not negligible. Therefore, a subtraction of the rest-SPECT from the 2nd SPECT is widely-used. However, subtracted SPECT images not only need to be corrected for the injected dose and the radiochemical purity due to inherent instability of HMPAO but also are usually degraded in quality. This study was undertaken to resolve these problems utilizing a change ratio (CR) map. The CR map was obtained by dividing 2nd SPECT by rest-SPECT. Prior to subtraction, the 2nd SPECT was normalized with the ratio of the mean whole brain counts between both SPECTs. To validate CR map, 7 patients were studied with both seq-SPECT and 133 Xe inhalation CBF measurement (Xe-CBF). The right to left count ratio obtained from the ROIs placed on MCA territory of CR map correlated well with that from Xe-CBF (r=0.89, p<0.01). Fifty-three patients with stroke underwent the seq-SPECT which was compared with the cerebral angiography (CAG) and classified into 4 groups according to the CR map. In 25 patients, all of the rest-, the subtracted-SPECT and the CR map did not show any difference between the affected side and the contralateral normal side. Seven patients with normal rest-SPECT showed decreased subtracted-SPECT counts and CR on the affected side. Three of them showed more than 75% stenosis on CAG. Four patients with the decreased counts both at the rest-and the subtracted-SPECT revealed no difference on the CR map suggesting the matched decrease of both blood flow and metabolism in the affected side. In conclusion, the CR map was a simple and useful method to evaluate the brain perfusion reserve with the seq-SPECT. (author)

  5. Identification of the target areas to be resected in patients with non-bullous emphysema by using gas and perfusion SPECT images

    International Nuclear Information System (INIS)

    Sugi, Kazuro; Ueda, Kazuhiro; Fujita, Nobuhiro; Nawata, Kouichi; Kaneda, Yoshikazu; Nawata, Sumihiko; Esato, Kensuke

    1997-01-01

    Significant improvement of pulmonary function after the volume reduction surgery has been reported in patients with bullous emphysema. However, there has been no successful report in patients with non-bullous emphysema. The reason of failure in patients with non-bullous emphysema should lie mainly on the difficulty to identify the target areas to be resected. We describe how to identify the target areas in the patients with non-bullous emphysema by using gas and perfusion single-photon emission computed tomography (SPECT). Twelve patients with non-bullous emphysema were studied by 133 Xe gas and 99m Tc MAA SPECT, which revealed that abnormal retention and low perfusion areas were located in the apex of the upper lobe and the basal segment of the lower lobe. The resections were performed thoracoscopically focused on the target areas by hockey-stick shape resection in the upper lobe and spiral shape resection in the lower lobe without deformity formation of the residual lung. Slight but significant improvement in the pulmonary functions was observed after the surgery in patients with non-bullous emphysema. The Xe gas and Tc MAA SPECT were useful procedures to identify the target areas to be resected in patients with non-bullous emphysema. (author)

  6. Radionuclide cisternography: SPECT and 3D-rendering

    International Nuclear Information System (INIS)

    Henkes, H.; Huber, G.; Piepgras, U.; Hierholzer, J.; Cordes, M.

    1991-01-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of 111 In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.) [de

  7. Diagnostic pathway of integrated SPECT/CT for coronary artery disease

    International Nuclear Information System (INIS)

    Slart, Riemer H.J.A.; Tio, Rene A.; Zijlstra, Felix; Dierckx, Rudi A.

    2009-01-01

    Treatment strategy in patients with suspected coronary artery disease (CAD) is driven by symptomatology in combination with diagnostic evaluation of the extent and/or severity of atherosclerosis in the coronary arteries and ischemia in the myocardium, i.e., the anatomic and functional correlates of CAD. Whereas multislice row computed tomography (MSCT) has the advantage of detecting coronary atherosclerosis at its earliest stages, thereby allowing initiation of appropriate therapeutic measures well before development of obstructive CAD, myocardial perfusion imaging (MPI) SPECT can clarify the hemodynamic consequences of the anatomic findings on MSCT based on a functional assessment of myocardial blood flow. There is a lack of correlation between coronary artery calcium (CAC), coronary artery stenosis, and MPI SPECT. Therefore CAC scoring and stress MPI should be thus considered complementary approaches rather than exclusionary in the evaluation of the patient at risk for CAD. The integration of anatomic and functional information may provide additional information for the clinician by the improved risk stratification and diagnostic accuracy of integrated techniques. The majority of previous studies are based on a sequential flowchart, starting with either SPECT or CAC scoring that finally directs the therapeutic strategy. Patients at low risk for CAD can be selected for primary prevention, and patients at high risk for CAD can be directly selected for coronary angiography (CAG). The remaining group of patients at intermediate risk for CAD can be substratified into lower- and higher-risk categories based on the presence or absence of stress-induced ischemia on MPI SPECT and CAC scoring. An integration of SPECT and CAC as a starting point for CAD detection in symptomatic patients at intermediate risk for CAD may facilitate a tailored diagnostic as well as therapeutic approach. Finally, using SPECT/CT, MPI SPECT, and CAC findings may be completed with CT angiography

  8. Upward creep of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT

    International Nuclear Information System (INIS)

    Friedman, J.; Van Train, K.; Maddahi, J.; Rozanski, A.; Prigent, F.; Bietendorf, J.; Waxman, A.; Berman, D.S.

    1989-01-01

    A new cause of artifactual 201 Tl defects on single photon emission computed tomography (SPECT) termed upward creep of the heart is described. In 102 consecutive patients undergoing 201 Tl SPECT, 30 (29%) demonstrated upward creep defined by an upward movement of the heart of greater than or equal to 2 pixels during acquisition. In 45 consecutive patients with a less than 5% likelihood of coronary artery disease, 17 (38%) had upward creep. Of these nine had reversible 201 Tl defects localized to the inferior and basal inferoseptal walls, while none of the 28 without upward creep had defects. The 17 low likelihood patients with upward creep had longer exercise duration and higher peak heart rate than those without upward creep. In five additional low likelihood patients with upward creep in whom imaging was immediately repeated, the upward creep pattern disappeared on the repeated images. After we changed our test protocol to begin imaging 15 min postexercise, only five (14%) of 36 low likelihood patients tested demonstrated upward creep. Upward creep is probably related to a transient increase in mean total lung volume early following exhaustive exercise, resulting in a mean lower position of the diaphragm (and thus the heart) at the beginning of imaging. The frequency of this source of false-positive 201 Tl studies can be reduced by delaying SPECT acquisition until 15 min postexercise

  9. Inclusion of functional information from perfusion SPECT improves predictive value of dose-volume parameters in lung toxicity outcome after radiotherapy for non-small cell lung cancer: A prospective study

    DEFF Research Database (Denmark)

    Farr, Katherina P; Kallehauge, Jesper F; Møller, Ditte S

    2015-01-01

    for corresponding standard parameters, but they were not significantly different from each other. CONCLUSION: SPECT-based functional parameters were better to predict the risk of RP compared to standard CT-based dose-volume parameters. Functional parameters may be useful to guide radiotherapy planning in order...

  10. SPECT and PET imaging in epilepsia

    International Nuclear Information System (INIS)

    Landvogt, C.

    2007-01-01

    In preoperative localisation of epileptogenic foci, nuclear medicine diagnostics plays a crucial role. FDG-PET is used as first line diagnostics. In case of inconsistent MRI, EEG and FDG-PET findings, 11 C-Flumazenil-PET or ictal and interictal perfusion-SPECT should be performed. Other than FDG, Flumazenil can help to identify the extend of the region, which should be resected. To enhance sensitivity and specificity, further data analysis using voxelbased statistical analyses or SISCOM (substraction ictal SPECT coregistered MRI) should be performed

  11. Juvenile spondylolysis: a comparative analysis of CT, SPECT and MRI

    International Nuclear Information System (INIS)

    Campbell, R.S.D.; Grainger, A.J.; Hide, I.G.; Papastefanou, S.; Greenough, C.G.

    2005-01-01

    To evaluate whether MRI correlates with CT and SPECT imaging for the diagnosis of juvenile spondylolysis, and to determine whether MRI can be used as an exclusive image modality. Juveniles and young adults with a history of extension low back pain were evaluated by MRI, CT and SPECT imaging. All images were reviewed blindly. Correlative analyses included CT vs MRI for morphological grading and SPECT vs MRI for functional grading. Finally, an overall grading system compared MRI vs CT and SPECT combined. Statistical analysis was performed using the kappa statistic. Seventy-two patients (mean age 16 years) were recruited. Forty pars defects were identified in 22 patients (31%), of which 25 were chronic non-union, five acute complete defects and ten acute incomplete fractures. Kappa scores demonstrated a high level of agreement for all comparative analyses. MRI vs SPECT (kappa: 0.794), MRI vs CT (kappa: 0.829) and MRI vs CT/SPECT (kappa: 0.786). The main causes of discrepancy were between MRI and SPECT for the diagnosis of stress reaction in the absence of overt fracture, and distinguishing incomplete fractures from intact pars or complete defects. MRI can be used as an effective and reliable first-line image modality for diagnosis of juvenile spondylolysis. However, localised CT is recommended as a supplementary examination in selected cases as a baseline for assessment of healing and for evaluation of indeterminate cases. (orig.)

  12. Juvenile spondylolysis: a comparative analysis of CT, SPECT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, R.S.D. [Royal Liverpool University Hospital, Department of Radiology, Liverpool (United Kingdom); Grainger, A.J. [Leeds General Infirmary, Department of Radiology, Leeds (United Kingdom); Hide, I.G. [Freeman Hospital, Department of Radiology, Newcastle upon Tyne (United Kingdom); Papastefanou, S. [James Cook University Hospital, Department Radiology, Middlesbrough (United Kingdom); Greenough, C.G. [James Cook University Hospital, Department of Trauma and Orthopaedics, Middlesbrough (United Kingdom)

    2005-02-01

    To evaluate whether MRI correlates with CT and SPECT imaging for the diagnosis of juvenile spondylolysis, and to determine whether MRI can be used as an exclusive image modality. Juveniles and young adults with a history of extension low back pain were evaluated by MRI, CT and SPECT imaging. All images were reviewed blindly. Correlative analyses included CT vs MRI for morphological grading and SPECT vs MRI for functional grading. Finally, an overall grading system compared MRI vs CT and SPECT combined. Statistical analysis was performed using the kappa statistic. Seventy-two patients (mean age 16 years) were recruited. Forty pars defects were identified in 22 patients (31%), of which 25 were chronic non-union, five acute complete defects and ten acute incomplete fractures. Kappa scores demonstrated a high level of agreement for all comparative analyses. MRI vs SPECT (kappa: 0.794), MRI vs CT (kappa: 0.829) and MRI vs CT/SPECT (kappa: 0.786). The main causes of discrepancy were between MRI and SPECT for the diagnosis of stress reaction in the absence of overt fracture, and distinguishing incomplete fractures from intact pars or complete defects. MRI can be used as an effective and reliable first-line image modality for diagnosis of juvenile spondylolysis. However, localised CT is recommended as a supplementary examination in selected cases as a baseline for assessment of healing and for evaluation of indeterminate cases. (orig.)

  13. Evaluation of Tl-201 SPECT imaging findings in prostate cancer

    Directory of Open Access Journals (Sweden)

    Sinem Ozyurt

    2015-07-01

    Full Text Available Objectives: To compare with histopathological findings the findings of prostate cancer imaging by SPECT method using Tl-201 as a tumor seeking agent. Methods: The study comprised 59 patients (age range 51-79 years, mean age 65.3 ± 6.8 years who were planned to have transrectal ultrasonography (TRUS-guided biopsies due to suspicion of prostate cancer between April 2011 and September 2011. Early planar, late planar and SPECT images were obtained for all patients. Scintigraphic evaluation was made in relation to uptake presence and patterns in the visual assessment and to Tumor/Background (T/Bg ratios for both planar and SPECT images in the quantitative assessment. Histopathological findings were compatible with benign etiology in 36 (61% patients and malign etiology in 23 (39% patients. Additionally, comparisons were made to evaluate the relationships between uptake patterns,total PSA values and Gleason scores. Results: A statistically significant difference was found between the benign and malignant groups in terms of uptake in planar and SPECT images and T/Bg ratios and PSA values. No statistically significant difference was found between uptake patterns of planar and SPECT images and Gleason scores in the malignant group. Conclusions: SPECT images were superior to planar images in the comparative assessment. Tl-201 SPECT imaging can provide an additional contribution to clinical practice in the diagnosis of prostate cancer and it can be used in selected patients.

  14. Role of brain SPECT in epilepsy exploration

    International Nuclear Information System (INIS)

    Biraben, A.; Bernard, AM.

    1996-01-01

    The management of epileptic patients is currently developing in relation with the introduction of video EEG and the opening of medical centers dedicated to epilepsy. The role of SPECT is now well established to assess the temporal and spatial dynamic phenomena during seizures. Ictal SPECT has technical and organisational requirements but is a very sensitive method, which appears to be superior to other available imaging techniques. (author)

  15. HM-PAO SPECT in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Cordes, M.; Rummeny, E.; Reissmann, M.; Fox, K.; Panitz, N.; Pfannenstiel, P.

    1987-01-01

    Single photon emission computed tomography (SPECT) after injection of 99m-Tc-HM-PAO was used to examine 34 patients whose clinical findings could not exclude a cerebrovascular disease. In all patients an X-ray computed tomography examination was inconclusive for the clinical-neurological findings. The regional cerebral bloodflow was pathologically disturbed in 10 of 34 patients in the HM-PAO SPECT examination. The detection of the regional cerebral bloodflow with HM-PAO SPECT is helpful in the diagnosis of cerebrovascular disease. (orig.) [de

  16. Thyroid mass estimation in Grave's disease by SPECT

    International Nuclear Information System (INIS)

    Pant, G.S.; Sharma, S.K.; Kumar, R.; Pandey, A.K.; Gupta, A.K.

    2002-01-01

    Aim: One of the important parts of treatment of Grave's disease with I-131 is the delivery of accurate dose to the target volume. Three important parameters that need to be accurately measured for dosimetry are; the 24 hr thyroid uptake (%), the thyroid mass and effective half life of I-131 in the gland. In this presentation we describe the estimation thyroid mass by SPECT. We have standardised a method to estimated thyroid volume by SPECT using thyroid phantoms of different sizes and then used them for routine thyroid mass estimation in patients with Graves' disease. Materials and Methods: Due to variation in thyroid weight in patients with Grave's disease, we standardised the scintigraphic (SPECT) technique using thyroid phantoms of different volumes such as 5 ml, 9.5 ml, 10.5 ml, 35 ml, 80 ml, 101ml and 110 ml. Each phantom was filled with 99 mTc solution with different activity concentration (100 μCi, 300 μCi, 600 μCi and 1.0 μCi) and SPECT images were acquired on a VARICAM dual head camera in 128x128 matrix. The acquired data was processed using a standardised Metz filter but without attenuation or scatter correction. Coronal slices were used with suitable threshold for edge detection. An irregular ROI was plotted around each lobe and isthmus of the thyroid gland and the enclosed slice area was measured. The area measured from all the frames was added and multiplied by the slice thickness to get the volume of the thyroid gland. The estimated volume of each phantom was compared and correlated with its actual volume. The thyroid mass in 40 patients was estimated by SPECT and compared with that estimated by ultrasonography.Results and Conclusion: The results of thyroid mass estimation with SPECT in phantom study suggested a 30% threshold for all phantom volumes. However, 35% threshold was used in patients' images for estimating thyroid volume. The estimated volumes by scintigraphy were compared with that estimated by ultrasonography. A correlation coefficient

  17. Silicon Detectors for PET and SPECT

    Science.gov (United States)

    Cochran, Eric R.

    Silicon detectors use state-of-the-art electronics to take advantage of the semiconductor properties of silicon to produce very high resolution radiation detectors. These detectors have been a fundamental part of high energy, nuclear, and astroparticle physics experiments for decades, and they hold great potential for significant gains in both PET and SPECT applications. Two separate prototype nuclear medicine imaging systems have been developed to explore this potential. Both devices take advantage of the unique properties of high resolution pixelated silicon detectors, designed and developed as part of the CIMA collaboration and built at The Ohio State University. The first prototype is a Compton SPECT imaging system. Compton SPECT, also referred to as electronic collimation, is a fundamentally different approach to single photon imaging from standard gamma cameras. It removes the inherent coupling of spatial resolution and sensitivity in mechanically collimated systems and provides improved performance at higher energies. As a result, Compton SPECT creates opportunities for the development of new radiopharmaceuticals based on higher energy isotopes as well as opportunities to expand the use of current isotopes such as 131I due to the increased resolution and sensitivity. The Compton SPECT prototype consists of a single high resolution silicon detector, configured in a 2D geometry, in coincidence with a standard NaI scintillator detector. Images of point sources have been taken for 99mTc (140 keV), 131I (364keV), and 22Na (511 keV), demonstrating the performance of high resolution silicon detectors in a Compton SPECT system. Filtered back projection image resolutions of 10 mm, 7.5 mm, and 6.7 mm were achieved for the three different sources respectively. The results compare well with typical SPECT resolutions of 5-15 mm and validate the claims of improved performance in Compton SPECT imaging devices at higher source energies. They also support the potential of

  18. Resting functional imaging tools (MRS, SPECT, PET and PCT).

    Science.gov (United States)

    Van Der Naalt, J

    2015-01-01

    Functional imaging includes imaging techniques that provide information about the metabolic and hemodynamic status of the brain. Most commonly applied functional imaging techniques in patients with traumatic brain injury (TBI) include magnetic resonance spectroscopy (MRS), single photon emission computed tomography (SPECT), positron emission tomography (PET) and perfusion CT (PCT). These imaging modalities are used to determine the extent of injury, to provide information for the prediction of outcome, and to assess evidence of cerebral ischemia. In TBI, secondary brain damage mainly comprises ischemia and is present in more than 80% of fatal cases with traumatic brain injury (Graham et al., 1989; Bouma et al., 1991; Coles et al., 2004). In particular, while SPECT measures cerebral perfusion and MRS determines metabolism, PET is able to assess both perfusion and cerebral metabolism. This chapter will describe the application of these techniques in traumatic brain injury separately for the major groups of severity comprising the mild and moderate to severe group. The application in TBI and potential difficulties of each technique is described. The use of imaging techniques in children will be separately outlined. © 2015 Elsevier B.V. All rights reserved.

  19. 123I-IMP single photon emission computed tomography (SPECT) study in childhood epilepsy

    International Nuclear Information System (INIS)

    Hara, Masafumi; Shimomura, Osamu; Kojima, Akihiro; Izunaga, Hiroshi; Tomiguchi, Seiji; Hirota, Yoshihisa; Taku, Keiichi; Miike, Teruhisa; Takahashi, Mutsumasa

    1990-01-01

    N-isopropyl-p[ 123 I]-iodoamphetamine (IMP) single photon emission computed tomography (SPECT), X-ray computed tomography (X-CT) and magnetic resonance imaging (MRI) were performed in 18 children with idiopathic seizures. In children with idiopathic seizures SPECT identified abnormal lesions in the highest rate (50%) compared with X-CT (11%) and MRI (13%), but the findings of SPECT poorly correlated with the foci on electroencephalography (EEG). Idiopathic epilepsy with abnormal uptake on SPECT was refractory to medical treatments and frequently associated with mental and/or developmental retardation. Perfusion defects identified on SPECT probably influenced the development of the brains in children. IMP SPECT is useful in the diagnosis and medical treatment in children with seizures. (author)

  20. Reference Range of Functional Data of Gated Myocardial Perfusion SPECT by Quantitative Gated SPECT of Cedars-Sinai and 4D-MSPECT of Michigan University

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Kim, Moo Hyun; Kim, Young Dae [College of Medicine, Univ. of Donga, Pusan (Korea, Republic of)

    2003-07-01

    Various programs have been developed for gating of myocardial perfusion SPECT. Among the those program, the most popular program is the Quantitative Gated SPECT (QGS)? developed by Cedars-Sinai hospital and most recently released program is 4D-MSPECT? developed by university of Michigan. It is important to know the reference range of the functional data of gated myocardial perfusion SPECT because it is necessary to determine abnormality of individual patient and echocardiographic data is different from those of gated SPECT. Tc-99m MIBI gated myocardial perfusion SPECT image was reconstructed by dual head gamma camera (Siemens, BCAM, esoft) as routine procedure and analyzed using QGS? and 4D-MSPECT? program. All patients (M: F=9: 18, Age 69{+-}9 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded: previous angina or MI history, ECG change with Q wave or ST-T change, diabetes melitius, hypercholesterolemia, typical chest pain, hypertension and cardiomyopathy. Pre-test likelihood of all patients was low. (1) In stress gated SPECT by QGS?, EDV was 73{+-}25 ml, ESV 25{+-}14 ml, EF 67{+-}11 % and area of first frame of gating 106.4{+-}21cm{sup 2}. In rest gated SPECT, EDV was 76{+-}26 ml, ESV 27{+-}15 ml, EF 66{+-}12 and area of first frame of gating 108{+-}20cm{sup 2}. (2) In stress gated SPECT by 4D-MSPECT?, EDV was 76{+-}28 ml, ESV 23{+-}16 ml, EF 72{+-}11 %, mass 115{+-}24 g and ungated volume 42{+-}15 ml. In rest gated SPECT, EDV was 75{+-}27 ml, ESV 23{+-}12 ml, EF 71{+-}9%, mass 113{+-}25g and ungate dvolume 42{+-}15 ml, (3) s-EDV, s-EF, r-ESV and r-EF were significantly different between QGS? and 4D-MSPECT? (each p=0.016, p<0.001. p=0.003 and p=0.001). We determined the normal reference range of functional parameters by QGS? and 4D-MSPECT? program to diagnose individually the abnormality of patients. And the reference ranges have to adopted to be patients by each specific gating program.

  1. 99mTc-HMPAO SPECT in patients with Alzheimer's disease and multiinfraction dementia

    International Nuclear Information System (INIS)

    Klisarova, A.; Tranulov, G.; Deleva, N.; Kaprelian, A.; Terzieva, M.; Ivanov, B.

    2002-01-01

    Alzheimer's disease (AD) and multiinfarktion dementia (MD) are the commonest causes giving rise to progressive cognitive function deficit in adult individuals. It is the purpose of the study to evaluate 99m Tc-HMPAO SPECT in making the diagnosis and differential diagnosis of Alzheimer's disease and multiinfarction dementia in patients presenting progressive cognitive disorders. Twenty patients with symptoms of dementia divided up in two groups (10 suspected for AD, and 10 with evidence of MD) are subjected to 99m Tc-HMPAO SPECT. To assay the scintigraphic images semi-quantitative perfusion indices are introduced. Bilateral hypoperfusion zones in the temporoparietal and temporal regions are detected in nine AD patients. In 4 of them in advanced stage of the disease hypoperfusion zones are found in the frontal lobe. In 8/10 MD patients vascular dependent hypoperfusion areas are located along the course of vessels. The perfusion indices implemented in practice contribute to the semi-quantitative evaluation of hypoperfusion areas and precise assessment of the scintigraphic findings. 99m Tc-HMPAO SPECT is an atraumatic, noninvasive technique, taken to be the method of choice in making the diagnosis and differential diagnosis of Alzheimer's disease and multiinfarction dementia in routine clinical practice. (authors)

  2. Affordable CZT SPECT with dose-time minimization (Conference Presentation)

    Science.gov (United States)

    Hugg, James W.; Harris, Brian W.; Radley, Ian

    2017-03-01

    PURPOSE Pixelated CdZnTe (CZT) detector arrays are used in molecular imaging applications that can enable precision medicine, including small-animal SPECT, cardiac SPECT, molecular breast imaging (MBI), and general purpose SPECT. The interplay of gamma camera, collimator, gantry motion, and image reconstruction determines image quality and dose-time-FOV tradeoffs. Both dose and exam time can be minimized without compromising diagnostic content. METHODS Integration of pixelated CZT detectors with advanced ASICs and readout electronics improves system performance. Because historically CZT was expensive, the first clinical applications were limited to small FOV. Radiation doses were initially high and exam times long. Advances have significantly improved efficiency of CZT-based molecular imaging systems and the cost has steadily declined. We have built a general purpose SPECT system using our 40 cm x 53 cm CZT gamma camera with 2 mm pixel pitch and characterized system performance. RESULTS Compared to NaI scintillator gamma cameras: intrinsic spatial resolution improved from 3.8 mm to 2.0 mm; energy resolution improved from 9.8% to reconstruction, result in minimized dose and exam time. With CZT cost improving, affordable whole-body CZT general purpose SPECT is expected to enable precision medicine applications.

  3. SPECT of aged backache patients

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Shigehiko; Nishikimi, Junzo; Mizuno, Naokado; Watanabe, Kentaro; Kondo, Masaki; Ozaki, Satoshi; Urasaki, Tetsuya; Muro, Toshiyuki [Prefectural Tajimi Hospital, Gifu (Japan)

    1995-12-01

    Single photon emission computed tomography (SPECT) using {sup 99m}Tc-HMDP was performed on 53 middle-aged or elderly patients (male 20, female, 33; age range, 40-80 years old) with lumbago, i.e., 25 patients with lumbar spondylosis, 15 with lumbar degenerative spondylolisthesis, 4 with spondylolytic spondylolisthesis, 3 with compression fracture, 3 with pulurent spondylitis, 2 with spondylous osteoporosis, and 1 with spinal osteodesmosis. {sup 99m}Tc-HMDP (740 MBq) was intravenously injected and regular SPECT was performed at 3 hours. Gamma camera was performed for about 10 seconds with 5deg intervals, and 36 steps (180deg) of collection was completed after about 6 minutes. The radioisotope accumulation, the presence or absence of sthenia, and its site were evaluated. Forty-seven (88.7%) patients showed excessive accumulation, i.e., 40 (75.5%) in peripheral vertebral osteophyte, 31 (58.5%) in vertebral articulations, and 10 (18.9%) in whole vertebral body. Significantly increased bilateral excessive accumulation was admitted in the vertebral articulations of sliding disc in degenerative spondylolisthesis. SPECT is considered useful in understanding the pathophysiology of degenerative lumber diseases. (S.Y.).

  4. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  5. Two dimensional polar display of cardiac blood pool SPECT

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Mamiya, Toshio; Takahashi, Taku; Takishima, Teruo; Hasegawa, Noriko; Hashimoto, Masanori; Ohno, Ken

    1989-01-01

    A new method of ECG gated cardiac blood pool SPECT to illustrate the left ventricular (LV) wall motion in a single static image, two dimensional polar display (2DPD), was described. Circumferential profiles of the difference between end diastolic and end systolic short axis images of the LV were displayed in a similar way to the bull's eye plot of 201 Tl myocardial SPECT. The diagnoses by 2DPDs agreed with those by cinematic displays of ECG gated blood pool SPECT in 74 out of 84 segments (85.5%) of abnormal motion, and 155 out of 168 segments (80.3%) of normal motion. It is concluded that 2DPD can evaluate regional wall motion by a single static image in a significant number of patients, and is also useful in comparing with the bull's eye image of 201 Tl myorcardial SPECT. (orig.)

  6. N-isopropyl I-123 p-iodoamphetamine (IMP) brain SPECT in dementia

    International Nuclear Information System (INIS)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Yoshikawa, Kohki; Ohtake, Tohru; Watanabe, Toshiaki; Iwata, Makoto; Shimizu, Teruo; Iio, Masahiro

    1988-01-01

    Six patients of Alzheimer's disease (AD), two patients of Pick disease (PD) and two patients of Creutzfeldt-Jakob disease (CJD) were studied with N-Isopropyl I-123 p-Iodoamphetamine (IMP) with SPECT. The pattern of IMP uptake in these demented groups were compared with that in five agematched normal controls and correlated with MRI and XCT. In all AD cases, SPECT revealed focal reduction of IMP uptake in frontal (6/6), parietal (6/6) and temporal (6/6) cortex, although MRI and XCT were normal. In both PD case, SPECT showed focal reduction of IMP uptake in frontal (1/2) and temporal (2/2) cortex with moderate labor atrophy on MRI and XCT. In both CJD case, SPECT showed diffuse reduction of IMP uptake in cerebral cortex in spite of no abnormality on MRI and XCT. These findings suggest that SPECT can detect earlier diseased process of AD and CJD than MRI or XCT and that SPECT may be helpful for the differential diagnosis of non-vascular dementia. (author)

  7. N-isopropyl I-123 p-iodoamphetamine (IMP) brain SPECT in dementia

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Yoshikawa, Kohki; Ohtake, Tohru; Watanabe, Toshiaki; Iwata, Makoto; Shimizu, Teruo; Iio, Masahiro

    1988-12-01

    Six patients of Alzheimer's disease (AD), two patients of Pick disease (PD) and two patients of Creutzfeldt-Jakob disease (CJD) were studied with N-Isopropyl I-123 p-Iodoamphetamine (IMP) with SPECT. The pattern of IMP uptake in these demented groups were compared with that in five agematched normal controls and correlated with MRI and XCT. In all AD cases, SPECT revealed focal reduction of IMP uptake in frontal (6/6), parietal (6/6) and temporal (6/6) cortex, although MRI and XCT were normal. In both PD case, SPECT showed focal reduction of IMP uptake in frontal (1/2) and temporal (2/2) cortex with moderate labor atrophy on MRI and XCT. In both CJD case, SPECT showed diffuse reduction of IMP uptake in cerebral cortex in spite of no abnormality on MRI and XCT. These findings suggest that SPECT can detect earlier diseased process of AD and CJD than MRI or XCT and that SPECT may be helpful for the differential diagnosis of non-vascular dementia.

  8. Validation of Left Ventricular Ejection Fraction with the IQ•SPECT System in Small-Heart Patients.

    Science.gov (United States)

    Yoneyama, Hiroto; Shibutani, Takayuki; Konishi, Takahiro; Mizutani, Asuka; Hashimoto, Ryosuke; Onoguchi, Masahisa; Okuda, Koichi; Matsuo, Shinro; Nakajima, Kenichi; Kinuya, Seigo

    2017-09-01

    The IQ•SPECT system, which is equipped with multifocal collimators ( SMART ZOOM) and uses ordered-subset conjugate gradient minimization as the reconstruction algorithm, reduces the acquisition time of myocardial perfusion imaging compared with conventional SPECT systems equipped with low-energy high-resolution collimators. We compared the IQ•SPECT system with a conventional SPECT system for estimating left ventricular ejection fraction (LVEF) in patients with a small heart (end-systolic volume IQ•SPECT. End-systolic volume, end-diastolic volume, and LVEF were calculated using quantitative gated SPECT (QGS) and cardioREPO software. We compared the LVEF from gated myocardial perfusion SPECT to that from echocardiographic measurements. Results: End-diastolic volume, end-systolic volume, and LVEF as obtained from conventional SPECT, IQ•SPECT, and echocardiography showed a good to excellent correlation regardless of whether they were calculated using QGS or using cardioREPO. Although LVEF calculated using QGS significantly differed between conventional SPECT and IQ•SPECT (65.4% ± 13.8% vs. 68.4% ± 15.2%) ( P = 0.0002), LVEF calculated using cardioREPO did not (69.5% ± 10.6% vs. 69.5% ± 11.0%). Likewise, although LVEF calculated using QGS significantly differed between conventional SPECT and IQ•SPECT (75.0 ± 9.6 vs. 79.5 ± 8.3) ( P = 0.0005), LVEF calculated using cardioREPO did not (72.3% ± 9.0% vs. 74.3% ± 8.3%). Conclusion: In small-heart patients, the difference in LVEF between IQ•SPECT and conventional SPECT was less when calculated using cardioREPO than when calculated using QGS. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  9. Regional cerebral blood flow and metabolism in patients with transient global amnesia. A study using SPECT and {sup 1}H-MRS

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Tetsuya; Hirata, Koichi; Tatsumoto, Muneto; Yamazaki, Kaoru [Dokkyo Univ., Tochigi (Japan). School of Medicine; Sato, Toshihiko

    1997-06-01

    In 13 patients with transient global amnesia (TGA), we studied the clinical course and changes over time by means of imaging techniques such as SPECT. MRI, and proton MR spectroscopy ({sup 1}H-MRS). In the case of SPECT, a cerebral blood flow decrease at the time center of the temporal lobe persisted at least for more than one month. In many patients, no abnormal signs were found on MRI. Despite the presence of intracranial impairment of energy metabolism, no evidence of cerebral ischemia was obtained using {sup 1}H-MRS at the acute and subacute stages. There were thus discrepancies between the symptoms and the findings of SPECT as well as the findings of {sup 1}H-MRS. These data suggest that TGA may not necessarily be caused by cerebra1 ischemia. (author)

  10. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  11. Clinical evaluation of the Tl-201 ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Mochizuki, Teruhito

    1989-01-01

    In order to evaluate the clinical usefulness of the Tl-201 ECG-gated myocardial single photon emission computed tomography (SPECT), we compared the wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT with the wall motion of the ECG-gated blood pool SPECT. Materials were 87 patients of 50 old myocardial infarctions (OMIs), 19 hypertrophic cardiomyopathies (HCMs), 2 dilated cardiomyopathies (DCMs) and 16 others. After intravenous injection of 111-185 MBq (3-5 mCi) of Tl-201 at rest, the projection data were acquired using a rotating gamma-camera through 180deg, from RAO 45deg in 24 directions, each of which consisted of 80-100 beats. For the reconstruction of ED, ES and non-gated images, R-R interval was divided into about 20 (18-22) fractions. In 348 regions of interest (anterior, septal, lateral and inferior wall) in 87 cases, wall motion and the Tl-201 uptake were evaluated to three grades (normal, hypokinesis and akinesis; normal, low and defect, respectively), which were compared with the wall motion of the ECG-gated blood pool SPECT. The wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT correlated well with the wall motion of the ECG-gated blood pool SPECT (96.6% and 87.9%, respectively). In conclusion, the ECG-gated myocardial SPECT can provide clear perfusion images and is a very useful diagnostic strategy to evaluate the regional wall motion and perfusion simultaneously. (author)

  12. Proceedings of clinical SPECT [single photon emission computed tomography] symposium

    International Nuclear Information System (INIS)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base

  13. Inguinal lymph node as the only evidence of progressive lung cancer

    Directory of Open Access Journals (Sweden)

    Zafer Kocak

    2008-09-01

    Full Text Available Abstact: Tumours that metastasise to groin nodes most frequently originate in genital and reproductive organs, skin, rectum or anus, or urinary bladder1,2. However, rare cases of inguinal metastases from tumours above the diaphragm have been reported2-5 and only three of them had an inguinal metastasis which was recognised antemortem and reported in detail in the English medical literature3-5. The primary tumours of these cases were malignant mesothelioma, salivary duct and breast carcinoma. In this paper, we report a case of carcinoma of the lung metastatic to an inguinal lymph node as the only evidence of progressive lung cancer. Resumo: Os tumores que metastizam para os gânglios inguinais têm frequentemente origem nos órgãos genitais e reprodutores, na pele, no recto ou ânus, ou na bexiga1,2. Há, no entanto, algumas descrições de casos raros de metástases inguinais de tumores localizados acima do diafragma2-5, e apenas três destes apresentavam uma metástase inguinal reconhecida antes da morte. Estes casos estão detalhadamente descritos na literatura médica de língua inglesa3-5. Os tumores primários destes casos eram mesotelioma maligno e carcinomas do conduto salivar e da mama. Descrevemos um caso de carcinoma do pulmão que metastizou para gânglio inguinal, como única evidência de cancro do pulmão progressivo. Key-words: Non-small cell lung carcinoma, inguinal lymph node, metastasis, disease progression, Palavras-chave: Carcinoma do pulmão de não pequenas células, gânglio inguinal, metástase, progressão da doença

  14. assessment of the clinical role of simultaneous 99mTc-MIBI and 201Tl dual-isotopic myocardial perfusion SPECT imaging in the patients wit hypertension

    International Nuclear Information System (INIS)

    Xie Wenhui; Zhang Lihua; Hu Shilong; Yang Shunfang; Zeng Jun

    2004-01-01

    Objective: To study the clinical role of Simultaneous rest technetium-99m sestamibi ( 99m Tc-MIBI) and stress thallium-201 (201Tl) Dual-isotopic myocardial perfusion SPECT imaging in the patients with hypertension. Methods: 116 patients with high blood pressure underwent simultaneous dual-isotopic myocardial perfusion SPECT imaging with 99m Tc-MIBI and 201Tl. 99m Tc-MIBI was injected at rest, 15 min later dobutamine was instilled into vein begin with 5 mg/kg/min, before and after instilling the base ECG, blood pressure, heart rate was recorded. when the maximal dose of Dobutamine was achieved, thallium-201 was injected, the dual-isotopic simultaneously SPECT imagine was performed. The stress and rest imagine was obtained. After tomographic reconstruction, the images were interpreted by two experienced observers without previous knowledge of results of other studies. Coronary angiography was performed in two weeks. All of 116 patients were found normal. Results: (1) All of 116 patients with high blood pressure were divided as three group by the course of disease: A group ( 20 year), 15. The heart/lung ratios of A, B, C group were 2.651±0.246, 2.546±0.231, 2.490±0.36 (mean±SD)respectively, no significant difference was noted among three group. Normal heart/lung ratios is 2.50±0.28 among of control group of 20. (2) The overall sensitivity for the dual-isotopic simultaneously myocardial SPECT imagine of high blood pressure was 46.55%(54/116). (3) Anterior, lateral, inferior, apex, interventricular septal segment were regarded as a whole segment, 111 segments display abnormal 201Tl uptake. 63, 30, 18 segments were in A, B, C group respectively, and no significant difference was noted among three group. 4 85 segments reveal reduced stressing 201Tl uptake and no typical redistribution was observed in the delay 201Tl imagines. 20, 24, 14, 12, 15 segments were in anterior, lateral, inferior, apex, interventricular septal segment respectively. 26 segments display

  15. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    International Nuclear Information System (INIS)

    Lacic, K.; Bokulic, T.; Lukac, J.; Dakovic, N.; Kusic, Z.

    1994-01-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more 'hot' and less 'cold' lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more 'hot' lesions than 4-6 hours SPECT. At the same time the number of 'cold' lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author)

  16. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Lacic, K; Bokulic, T; Lukac, J; Dakovic, N; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine

    1994-10-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more `hot` and less `cold` lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more `hot` lesions than 4-6 hours SPECT. At the same time the number of `cold` lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author).

  17. Skeletal scintigraphy and SPECT/CT in orthopedic imaging

    International Nuclear Information System (INIS)

    Klaeser, B.; Walter, M.; Krause, T.

    2011-01-01

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  18. Reduced CBF recovery detected by longitudinal 3D-SSP SPECT analyses predicts outcome of postoperative patients after subarachnoid haemorrhage.

    Science.gov (United States)

    Mutoh, Tatsushi; Totsune, Tomoko; Takenaka, Shunsuke; Tatewaki, Yasuko; Nakagawa, Manabu; Suarez, Jose I; Taki, Yasuyuki; Ishikawa, Tatsuya

    2018-02-01

    The aim of this study was to evaluate the impact of cerebral blood flow (CBF) recovery obtained from brain single-photon emission computed tomography (SPECT) images on postoperative outcome after aneurysmal subarachnoid haemorrhage (SAH). Twenty-nine patients who had undergone surgical clipping for ruptured anterior communicating artery aneurysms were analyzed prospectively. Routine measurements of CBF were performed using technetium-99 m hexamethyl propyleneamine oxine SPECT on days 4 and 14 after SAH. Regional voxel data analyzed by three dimensional stereotactic surface projection (3D-SSP) were compared between patients and age-matched normal database (NDB). In 3D-SSP analysis of all patients, cortical hypoperfusion around the surgical site in bilateral frontal lobes was evident on day 4 (P SSP SPECT image analyses can be a potential predictor of poor prognosis in postoperative patients after SAH. © 2017 John Wiley & Sons Australia, Ltd.

  19. Clinical application of SPECT and PET in cerebrovascular disease

    International Nuclear Information System (INIS)

    Ra, Young Shin

    2003-01-01

    Single photon emission computed tomography(SPECT) and positron emission tomography(PET) are modern imaging techniques that allow for both qualitative are quantitative assessment of hemodynamic changes in cerebrovascular diseases. SPECT has been becoming an indispensable method to investigate regional cerebral blood flow because equipment and isotope are easily available in most general hospitals. Acetazolamide stress SPECT has also been proved to be useful to evaluate the cerebrovascular reserve of occlusive cerebrovascular diseases and to select surgical candidate. PET has gained wide spread clinical use in the evaluation of the hemodynamic and metabolic consequences of extracranial or intracranial arterial obstructive disease despite its complexity and limited availability. PET has been established as an invaluable tool in the pathophysilogy investigation of acute ischemic stroke. The potentials, limitations, and clinical applications of SPECT and PET in various cerebrovascular diseases will be discussed in this article with reviews of literatures

  20. Initial Investigation of preclinical integrated SPECT and MR imaging.

    Science.gov (United States)

    Hamamura, Mark J; Ha, Seunghoon; Roeck, Werner W; Wagenaar, Douglas J; Meier, Dirk; Patt, Bradley E; Nalcioglu, Orhan

    2010-02-01

    Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.

  1. Clinical application of SPECT and PET in cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Ra, Young Shin [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    Single photon emission computed tomography(SPECT) and positron emission tomography(PET) are modern imaging techniques that allow for both qualitative are quantitative assessment of hemodynamic changes in cerebrovascular diseases. SPECT has been becoming an indispensable method to investigate regional cerebral blood flow because equipment and isotope are easily available in most general hospitals. Acetazolamide stress SPECT has also been proved to be useful to evaluate the cerebrovascular reserve of occlusive cerebrovascular diseases and to select surgical candidate. PET has gained wide spread clinical use in the evaluation of the hemodynamic and metabolic consequences of extracranial or intracranial arterial obstructive disease despite its complexity and limited availability. PET has been established as an invaluable tool in the pathophysilogy investigation of acute ischemic stroke. The potentials, limitations, and clinical applications of SPECT and PET in various cerebrovascular diseases will be discussed in this article with reviews of literatures.

  2. SPECT-CT in the diagnosis of coronary artery disease; SPECT-CT in der Diagnostik der koronaren Herzerkrankung

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M. [Klinik und Poliklinik fuer Nuklearmedizin, Klinikum der Univ. Muenchen (Germany)

    2006-09-15

    Two-dimensional invasive coronary angiography (ICA), although showing high temporal and spatial resolution, is neither able to predict the physiologic relevance of a stenosis nor able to determine the prognosis of both symptomatic and asymptomatic patients. Therefore, the ICA can hardly represent the sole gold standard in clinical decision making. Additionally, the small but distinct morbidity and mortality rate of this method and the inconvenience of patients undergoing ICA have strengthened the search for a non-invasive alternative. Recent publications have shown high accuracy for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to ICA in detecting 'obstructive' coronary artery disease, defined as stenosis of more than 50%. Otherwise, although well known limitations of MDCT like motion artifacts or severe vessel calcifications could be clearly reduced with the newest scanner generation, this technique lacks of delivering exact lumen quantification compared to ICA in a clinical setting. Furthermore, there is evidence that exact quantification of coronary artery stenoses is of minor impact on clinical decision making, if lesion location and functional status are known. A first publication showed that combined imaging of MDCT angiography and PET myocardinal perfusion scanning with [{sup 13}N]ammonia was feasible with an integrated PET/CT scanner and reported high sensitivity and specificity to detect hemodynamically relevant coronary artery stenoses compared to the combination of PET plus ICA. However, PET perfusion tracers are not widely available at present and the well accepted reference for detecting myocardial ischemia, based on numerous publications, is myocardial perfusion SPECT (MPI). MPI is an established method for the non-invasive assessment of functional significance of coronary stenoses and delivers valuable information for risk stratification. Patients with stable angina and normal stress sestamibi

  3. Implementation and Evaluation of Pinhole SPECT

    International Nuclear Information System (INIS)

    MacArtain Anne Marie

    2002-08-01

    The aim of this work was to implement Pinhole SPECT into a working Nuclear Medicine department. It has been reported that pinhole SPECT has been successfully performed to visualise pathology in ankle bones using gamma camera and the images were constructed using a standard filtered back-projection algorithm (Bahk YW, 1998). The objective of this study was to produce and evaluate this technique with the equipment available in the nuclear medicine department. The system performance was assessed using both the low-energy high resolution and the pinhole collimators. Phantoms constructed using capillary tubes, filled with technetium 99m (pertechnetate) were imaged in different arrays to identify possible limitations in the reconstruction software. A thyroid phantom with hot and cold inserts was also imaged. Data was acquired in ''tep-and-shoot'' mode as the camera was rotated 180 degrees or 360 degrees around the phantom. Images were reconstructed using standard parallel back-projection algorithm and a weighted backprojection algorithm (Nowak). An attempt was made to process images of the phantom in Matlab using the Iradon function modified by application of a cone-beam type algorithm (Feldkamp L, 1984). Visual comparison of static images between the pinhole and the LEHR collimators showed the expected improved spatial resolution of the pinhole images. Pinhole SPECT images should be reconstructed using the appropriate cone beam algorithm. However, it was established that reconstructing pinhole SPECT images using a standard parallel backprojection algorithm yielded results which were deemed to be clinically useful. The Nowak algorithm results were a distinct improvement on those achieved with the parallel backprojection algorithm. Likewise the results from the cone beam algorithm were better than the former but not as good as those obtained from the Nowak algorithm. This was due to the fact that the cone beam algorithm did not include a weighting factor. Implementation

  4. Brain SPECT in childhood; Temp cerebrale chez l'enfant

    Energy Technology Data Exchange (ETDEWEB)

    Tranquart, F.; Saliba, E.; Prunier, C.; Baulieu, F.; Besnard, J.C.; Guilloteau, D.; Baulieu, J.L. [Hopital Bretonneau, Service de Medecine Nucleaire, Unite Inserm 316, 37 - Tours (France)

    2001-04-01

    The modalities and the indications of perfusion and neurotransmission SPECT in childhood are presented. The perfusion as well as neurotransmission tracers have not yet authorization for use in children; they have to be used by prescription of magistral preparation or in research protocols. The radioprotection rules have to be strictly respected. The most frequent indication of perfusion SPECT is pharmacologically resistant epilepsy; the ictal SPECT before surgery allows the localization of the epileptogenic focus. Other indications are relevant in the prognosis of neonatal anoxia and encephalitis. In psychiatric disorders, especially in autism, the interest is the physiopathological approach of the brain dysfunctions. The neurotransmission SPECT is emerging as a consequence of the development of new radiotracer, as the dopaminergic system ligands. The decrease of the dopamine D2 receptors in the striatum can be imaged and quantified in the neonate. The lesions of dopamine system seem to be a consequence of the neonatal hypoxia-ischemia and it is predictive of motor sequelae. Brain SPECT should become a routine examination in child neurologic and psychiatric disorders. (authors)

  5. The future of SPECT in a time of PET

    International Nuclear Information System (INIS)

    Jansen, Floris P.; Vanderheyden, Jean-Luc

    2007-01-01

    As positron emission tomography (PET) imaging is becoming more prevalent in clinical practice, it is reasonable to ask if there will be a role for single photon emission computed tomography (SPECT) in the future. This article considers that question, focusing on areas where SPECT can differentiate itself from PET for fundamental reasons: breadth of available radionuclides, simultaneous imaging of multiple agents, cost-effectiveness and adaptability to specific imaging situations. The conclusion is that SPECT will continue to evolve and exist alongside PET and will grow the field of molecular imaging with improved efficiency and patient workflow

  6. The role of brain SPECT in children with epilepsy

    International Nuclear Information System (INIS)

    Liu Xingdang; Liu Yongchang; Lin Xiangtong

    1996-01-01

    The rCBF brain SPECT with 99m Tc-HMPAO was performed in 15 children with interictal epilepsy, and some cases were compared with EEG, X-ray CT and MRI. The results showed that the positive rate of SPECT was the highest (93.33%,), then the EEG (92.31%), and the CT and MRI were the lowest (66.67% and 75%). This study indicated that brain SPECT was an effective method for diagnosis and foci localization in epileptic children, and also was useful to the study of prognosis and relationship between changes of rCBF and progress in clinical pictures

  7. Brain SPECT in the pre-surgical evaluation of epileptic patients

    International Nuclear Information System (INIS)

    Buchpiguel, C.A.; Cukiert, A.; Hironaka, F.H.; Cerri, G.G.; Magalhaes, A.E.A.; Marino Junior, R.

    1992-01-01

    Fifteen adult epileptic patients were studied pre-operatively using a rotational scintillation camera interfaced to a dedicated computer. The tomographic images were obtained 15 minutes after intravenous injection of 99 m Tc-HMPAO. All had MRI scanning and intensive EEG monitoring which generally included seizure recording. Five patients had progressive lesions (3 meningiomas, 2 astrocytomas). In 10 patients, neuroradiological studies did not show the presence of progressive lesions (2 normal scans and 8 cases with inactive lesions). Two patients with meningioma showed hypoperfusion at the lesion site while the third patient had a marked hypoperfusion which might correlate with the clinical diagnosis of epilepsia partialis continua. In the astrocytoma patients SPECT scans showed hypoperfusion at the lesion site. Data obtained from the 10 patients without progressive CNS lesions showed: in 4, SPECT findings correlated well with the anatomical findings; in 5 instances, SPECT was able to disclose additional functional deficits; in one case, there was no SPECT correlate of a discrete anatomical lesion. In 5 of these cases with no progressive lesions (n=10) SPECT findings were useful as a complementary tool in determining the clinical or surgical management of these patients. Despite the small number and heterogeneity of the present sample, SPECT seems to be an useful tool as part of the clinical workup of epileptic who are candidates for epilepsy surgery. (author)

  8. SPECT versus planar bone radionuclide imaging in the detection of spondylolysis

    International Nuclear Information System (INIS)

    Whitten, C.G.; El-Khoury, G.Y.; Chang, P.J.; Seabold, J.E.; Found, E.M.; Renfrew, D.L.

    1991-01-01

    This paper evaluates the relative performance and ease of interpretation of SPECT versus planar radionuclide bone imaging in the detection of spondylolysis. The authors studied all patients presenting with back pain suggestive of spondylolysis from November 1989 to January 1991 who underwent bone scanning; patients underwent both planar and SPECT imaging. The planar and SPECT images were randomly mixed and independently interpreted by four observers for presence or absence of spondylolysis and ease of interpretation for each scan. Receiver operating characteristic (ROC) and analysis of variance (ANOVA) were used. Of 72 patients, 19 had confirmed spondylolysis, and 53 did not. While ROC analysis showed that SPECT performed slightly better than planar imaging for all four observers, the difference was not statistically significant. ANOVA results suggest that planar imaging was significantly easier to use than SPECT and that ease of use was strongly correlated with the observer's confidence in the diagnosis

  9. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    International Nuclear Information System (INIS)

    Sundstroem, Torbjoern; Riklund, Katrine Aa.; Elgh, Eva; Naesman, Birgitta; Larsson, Anne; Nyberg, Lars

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2±4.8 years) with mild AD and 18 healthy elderly (69.4±3.9 years) were included in the study. The subjects were injected with 99m Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF 99m Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  10. Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: takahsr@hs.med.kyushu-u.ac.jp; Sasaki, Masayuki [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Himuro, Kazuhiko; Yamashita, Yasuo; Komiya, Isao [Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Baba, Shingo [Department of Clinical Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2015-04-15

    Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually

  11. High-resolution tomography of positron emitters with clustered pinhole SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Goorden, Marlies C; Beekman, Freek J [Section of Radiation Detection and Medical Imaging, Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands)], E-mail: m.c.goorden@tudelft.nl

    2010-03-07

    State-of-the-art small-animal single photon emission computed tomography (SPECT) enables sub-half-mm resolution imaging of radio-labelled molecules. Due to severe photon penetration through pinhole edges, current multi-pinhole SPECT is not suitable for high-resolution imaging of photons with high energies, such as the annihilation photons emitted by positron emitting tracers (511 keV). To deal with this edge penetration, we introduce here clustered multi-pinhole SPECT (CMP): each pinhole in a cluster has a narrow opening angle to reduce photon penetration. Using simulations, CMP is compared with (i) a collimator with traditional pinholes that is currently used for sub-half-mm imaging of SPECT isotopes (U-SPECT-II), and (ii), like (i) but with collimator thickness adapted to image high-energy photons (traditional multi-pinhole SPECT, TMP). At 511 keV, U-SPECT-II is able to resolve the 0.9 mm rods of an iteratively reconstructed Jaszczak-like capillary hot rod phantom, and while TMP only leads to small improvements, CMP can resolve rods as small as 0.7 mm. Using a digital tumour phantom, we show that CMP resolves many details not assessable with standard USPECT-II and TMP collimators. Furthermore, CMP makes it possible to visualize uptake of positron emitting tracers in sub-compartments of a digital mouse striatal brain phantom. This may open up unique possibilities for analysing processes such as those underlying the function of neurotransmitter systems. Additional potential of CMP may include (i) the imaging of other high-energy single-photon emitters (e.g. I-131) and (ii) localized imaging of positron emitting tracers simultaneously with single photon emitters, with an even better resolution than coincidence PET.

  12. Tc-99m-bicisate (ECD)-brain-SPECT in rapidly progressive dementia; Hirn-SPECT mit Tc-99m-Bicisat (ECD) bei rasch progredientem dementiellen Syndrom

    Energy Technology Data Exchange (ETDEWEB)

    Marienhagen, J.; Eilles, C. [Regensburg Univ. (Germany). Abt. fuer Nuklearmedizin; Weingaertner, U.; Blaha, L. [Bezirkskrankenhaus Mainkofen (Germany). Psychiatrische Klinik; Zerr, I.; Poser, S. [Goettingen Univ. (Germany). Klinik und Poliklinik fuer Neurologie

    1999-07-01

    We present a 61-year-old male patient with progressive dementia. A brain SPECT with Tc-99m-bicisate was performed for confirmation of clinically suspected Alzheimer-dementia. At the time of the SPECT-investigation marked apraxia and aphasia besides severe dementia were present. Electrophysiological as well as anatomical neuroimaging findings showed non-diagnostic alterations. SPECT revealed distinct perfusion defects, which made Alzheimer Dementia unlikely. The further course of the patient was determined by rapidly progressive deterioration with development of akinetic mutism. Thereafter, increased levels of neuron-specific enolase as well as 14-3-3 proteins were found in the cerebro-spinal fluid (CSF). The patient finally died with signs of cerebral decortication. Due to the clinical course and the CSF-findings the patient's final diagnosis was Creutzfeld-Jakob-disease, nevertheless no autopsy was performed. The presented case report underscores the clinical utility of perfusion brain SPECT in the differential diagnosis of dementias. (orig.) [German] Wir berichten ueber einen 61jaehrigen Patienten mit progredientem dementiellen Syndrom, der unter der Verdachtsdiagnose einer Demenz vom Alzheimer-Typ (DAT) zur Hirn-SPECT-Untersuchung mit TC-99m-Bicisat (ECD) vorgestellt wurde. Zum Untersuchungszeitpunkt bestanden neben dem Vollbild einer Demenz eine ausgepraegte Apraxie und Aphasie bei unspezifischen Veraenderungen im EEG sowie der neuroradiologischen Bildgebung. In der Hirn-SPECT-Untersuchung fanden sich fuer eine DAT untypische ausgedehnte, vorwiegend rechtshemisphaerische Perfusionsstoerungen. Im weiteren Verlauf rasche Progredienz des Krankheitsbildes mit Entwicklung eines akinetischen Mutismus sowie Nachweis erhoehter Werte der neuronspezifischen Enolase und des 14-3-3-Proteins im Liquor. Der Patient verstarb schliesslich unter dem Bild einer Decortication. Aufgrund des klinischen Verlaufs sowie der Liquorbefunde wurde, da eine autoptische Befundsicherung

  13. Pre-evaluation study in SPECT images using a phantom

    International Nuclear Information System (INIS)

    Rebelo, Marina de Sa; Furuie, Sergio Shiguemi; Abe, Rubens; Moura, Lincoln

    1996-01-01

    An alternative solution for the reconstruction of SPECT images using a Poisson Noise Model is presented. The proposed algorithm was applied on a real phantom and compared to the standard clinical procedures. Results have shown that the proposed method improves the quality of the SPECT images

  14. Prospective study of p-[{sup 123}I]iodo-L-phenylalanine and SPECT for the evaluation of newly diagnosed cerebral lesions: specific confirmation of glioma

    Energy Technology Data Exchange (ETDEWEB)

    Hellwig, Dirk; Schaefer, Andrea; Farmakis, Georgios; Grgic, Aleksandar; Kirsch, Carl-Martin [Saarland University Medical Center, Department of Nuclear Medicine, Homburg/Saar (Germany); Ketter, Ralf; Moringlane, Jean R.; Steudel, Wolf-Ingo [Saarland University Medical Center, Department of Neurosurgery, Homburg (Germany); Romeike, Bernd F.M. [Saarland University Medical Center, Institute of Neuropathology, Homburg (Germany); Friedrich-Schiller-University, Department of Neuropathology, Jena (Germany); Samnick, Samuel [Saarland University Medical Center, Department of Nuclear Medicine, Homburg/Saar (Germany); University of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany)

    2010-12-15

    The differentiation between gliomas, metastases and gliotic or inflammatory lesions by imaging techniques remains a challenge. Gliomas frequently exhibit increased uptake of radiolabelled amino acids and are thus amenable to PET or SPECT imaging. Recently, p-[{sup 123}I]iodo-L-phenylalanine (IPA) was validated for the visualization of glioma by SPECT and received orphan drug status. Here we investigated its diagnostic performance for differentiating indeterminate brain lesions. This prospective open study included 67 patients with newly diagnosed brain lesions suspicious for glioma (34 without and 33 with contrast enhancement in the MRI scan). Patients received 250 MBq IPA intravenously after overnight fasting. SPECT images at 30 min and 3 h post-injection were iteratively reconstructed and visually interpreted after image fusion with an MRI brain scan (fluid-attenuated inversion recovery sequence or T1-weighted contrast-enhanced image). Findings were correlated with results of stereotactic or open biopsies or serial imaging. Twenty-seven low-grade (2 WHO I, 25 WHO II) and 24 high-grade gliomas (1 WHO III, 23 WHO IV), 3 metastases originating from lung cancer as well as 13 non-neoplastic lesions were proven. All non-neoplastic lesions and all metastases were negative with IPA SPECT. Forty gliomas were true-positive (TP) and 11 false-negative (FN) findings (8 WHO II, 1 WHO III, 2 WHO IV) occurred. There were no false-positive (FP) findings. For the differentiation of primary brain tumours and non-neoplastic lesions, sensitivity and specificity were 78 and 100%. In 34 lesions without contrast enhancement in MRI, IPA SPECT resulted in 17 TP, 8 true-negative, 9 FN and no FP findings (sensitivity 65%, specificity 100%). In patients with suspected glioma, IPA SPECT shows a high specificity, but especially in low-grade gliomas FN findings may occur. Due to the high positive predictive value a positive finding allows a suspected glioma to be confirmed. (orig.)

  15. Radiotracers for SPECT imaging. Current scenario and future prospects

    International Nuclear Information System (INIS)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S.

    2012-01-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [ 123 I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [ 123 I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also makes them more

  16. Radiotracers for SPECT imaging. Current scenario and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S. [GE Healthcare Medical Diagnostics, John F. Welch Technology Center, Bangalore (India).; Bhalla, R.; Pickett, R.; Luthra, S.K. [GE Healthcare Medical Diagnostics, The Grove Centre, Amersham (United Kingdom)

    2012-07-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [{sup 123}I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [{sup 123}I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also

  17. Clinical evaluation of 123I-IMP SPECT in patients with various neurological diseases

    International Nuclear Information System (INIS)

    Yoneda, Naoto

    1993-01-01

    Single photon emission computed tomography with N-isopropyl-p-[ 123 I] iodoamphetamine ( 123 I-IMP SPECT) was performed in 57 patients with various neurological disease, and compared with the findings of brain CT, MRI, and EEG. The author also evaluated the relationship between the findings on 123 I-IMP SPECT and the condition of the control of the attack after treatment with antiepileptic drugs in idiopathic epileptic patients. Abnormality of accumulation of 123 I-IMP SPECT was observed in 62.3% of all cases. Focal abnormality was detected in 28.3% of all cases by brain CT and 54.1% by MRI. The detectability of focal abnormality in brain CT and MRI was found to be lower than that of 123 I-TMP SPECT. There was very little significance in detectability between 123 I-IMP SPECT and EEG. But it infers that 123 I-IMP SPECT can detect the subictal state in epileptic patients. One comparative study of the relationship between the findings on 123 I-IMP SPECT and the condition of the control of the attack by antiepileptic drugs in patients with idiopathic epilepsy, abnormality of 123 I-IMP SPECT findings was found to be higher in patients who were not controlled sufficiently than in patients who were controlled sufficiently, and a significant difference is found by X 2 test. 123 I-IMP SPECT is useful for the evaluation of treatment in patients with epilepsy. (author)

  18. Delayed lung scintigraphy with N-isopropyl-I-123-p-iodoamphetamine in lung cancer and inflammatory disease

    Energy Technology Data Exchange (ETDEWEB)

    Suematsu, Toru; Narabayashi, Isamu; Takada, Yoshiki and others

    1989-01-01

    Lung studies with N-Isopropyl-I-123-p-Iodoamphetamine (IMP) were performed on patients with lung cancer or inflammatory disease. In the present study, we evaluated the usefulness of the delayed scintigraphy. The subjects consisted of 27 patients with lung cancer (34 lesions), 3 with radiation pneumonitis, 2 with interstitial pneumonitis, 2 with old tuberculous lesion (tuberculomas), 1 with diffuse panbronchiolitis, 1 with pneumonia and 1 with lung abscess. The delayed scintigraphy was performed 24 hr after intravenous injection of 3 mCi IMP, in sitting position. In 10 patients, SPECT images were obtained following the delayed scintigraphy. Delayed scintigraphic appearances of lung cancer were classified into 5 types, high IMP uptake in the area congruent with the lesion of atelectasis and/or obstructive pneumonia (Type I), high IMP uptake in the area surrounded the tumor (Type II), a defect in the area consistent with the tumor and no high IMP uptake in the area surrounded the tumor (Type III), high IMP uptake in the area almost congruent with the tumor (Type IV) and no significant change (Type V). Excluding 10 lesions with Type IV or V, no IMP uptake was seen in the areas congruent with the tumors. Type II was the most frequently observed pattern. Normal scintigrams (Type V) were observed in 8 lesions, whose sizes were fairly small. There was no definite trend caused by difference in histological types of cancers. In 8 patients with viable inflammatory disease of the lung, the delayed scintigrams showed high IMP uptake in the areas congruent with the abnormalities on chest roentgenograms. On the other hand, no uptake was seen in the old tuberculous lesions. (J.P.N.).

  19. Delayed lung scintigraphy with N-isopropyl-I-123-p-iodoamphetamine in lung cancer and inflammatory disease

    International Nuclear Information System (INIS)

    Suematsu, Toru; Narabayashi, Isamu; Takada, Yoshiki

    1989-01-01

    Lung studies with N-Isopropyl-I-123-p-Iodoamphetamine (IMP) were performed on patients with lung cancer or inflammatory disease. In the present study, we evaluated the usefulness of the delayed scintigraphy. The subjects consisted of 27 patients with lung cancer (34 lesions), 3 with radiation pneumonitis, 2 with interstitial pneumonitis, 2 with old tuberculous lesion (tuberculomas), 1 with diffuse panbronchiolitis, 1 with pneumonia and 1 with lung abscess. The delayed scintigraphy was performed 24 hr after intravenous injection of 3 mCi IMP, in sitting position. In 10 patients, SPECT images were obtained following the delayed scintigraphy. Delayed scintigraphic appearances of lung cancer were classified into 5 types, high IMP uptake in the area congruent with the lesion of atelectasis and/or obstructive pneumonia (Type I), high IMP uptake in the area surrounded the tumor (Type II), a defect in the area consistent with the tumor and no high IMP uptake in the area surrounded the tumor (Type III), high IMP uptake in the area almost congruent with the tumor (Type IV) and no significant change (Type V). Excluding 10 lesions with Type IV or V, no IMP uptake was seen in the areas congruent with the tumors. Type II was the most frequently observed pattern. Normal scintigrams (Type V) were observed in 8 lesions, whose sizes were fairly small. There was no definite trend caused by difference in histological types of cancers. In 8 patients with viable inflammatory disease of the lung, the delayed scintigrams showed high IMP uptake in the areas congruent with the abnormalities on chest roentgenograms. On the other hand, no uptake was seen in the old tuberculous lesions. (J.P.N.)

  20. Stereotactic radiosurgery planning with ictal SPECT images

    International Nuclear Information System (INIS)

    Ackerly, T.; RMIT University, Bundoora, VIC; Geso, M.; O'Keefe, G.; Smith, R.

    2004-01-01

    This paper is motivated by a clinical requirement to utilise ictal SPECT images for target localisation in stereotactic radiosurgery treatment planning using the xknife system which only supports CT and MRI images. To achieve this, the SPECT images were converted from raw (pixel data only) format into a part 10 compliant DICOM CT fileset. The minimum requirements for the recasting of a raw format image as DICOM CT or MRI data set are described in detail. The method can be applied to the importation of raw format images into any radiotherapy treatment planning system that supports CT or MRI import. It is demonstrated that the combination of the low spatial resolution SPECT images, depicting functional information, with high spatial resolution MRI images, which show the structural information, is suitable for stereotactic radiosurgery treatment planning. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  1. Effects of cross talk on dual energy SPECT imaging between 123I-BMIPP and 201Tl

    International Nuclear Information System (INIS)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.)

  2. Quantitative Evidence for Revising the Definition of Primary Graft Dysfunction after Lung Transplant.

    Science.gov (United States)

    Cantu, Edward; Diamond, Joshua M; Suzuki, Yoshikazu; Lasky, Jared; Schaufler, Christian; Lim, Brian; Shah, Rupal; Porteous, Mary; Lederer, David J; Kawut, Steven M; Palmer, Scott M; Snyder, Laurie D; Hartwig, Matthew G; Lama, Vibha N; Bhorade, Sangeeta; Bermudez, Christian; Crespo, Maria; McDyer, John; Wille, Keith; Orens, Jonathan; Shah, Pali D; Weinacker, Ann; Weill, David; Wilkes, David; Roe, David; Hage, Chadi; Ware, Lorraine B; Bellamy, Scarlett L; Christie, Jason D

    2018-01-15

    Primary graft dysfunction (PGD) is a form of acute lung injury that occurs after lung transplantation. The definition of PGD was standardized in 2005. Since that time, clinical practice has evolved, and this definition is increasingly used as a primary endpoint for clinical trials; therefore, validation is warranted. We sought to determine whether refinements to the 2005 consensus definition could further improve construct validity. Data from the Lung Transplant Outcomes Group multicenter cohort were used to compare variations on the PGD definition, including alternate oxygenation thresholds, inclusion of additional severity groups, and effects of procedure type and mechanical ventilation. Convergent and divergent validity were compared for mortality prediction and concurrent lung injury biomarker discrimination. A total of 1,179 subjects from 10 centers were enrolled from 2007 to 2012. Median length of follow-up was 4 years (interquartile range = 2.4-5.9). No mortality differences were noted between no PGD (grade 0) and mild PGD (grade 1). Significantly better mortality discrimination was evident for all definitions using later time points (48, 72, or 48-72 hours; P definition can be simplified by combining lower PGD grades. Construct validity of grading was present regardless of transplant procedure type or use of mechanical ventilation. Additional severity categories had minimal impact on mortality or biomarker discrimination.

  3. Development of a new statistical evaluation method for brain SPECT images

    International Nuclear Information System (INIS)

    Kawashima, Ryuta; Sato, Kazunori; Ito, Hiroshi; Koyama, Masamichi; Goto, Ryoui; Yoshioka, Seiro; Ono, Shuichi; Sato, Tachio; Fukuda, Hiroshi

    1996-01-01

    The purpose of this study was to develop a new statistical evaluation method for brain SPECT images. First, we made normal brain image databases using 99m Tc-ECD and SPECT in 10 normal subjects as described previously. Each SPECT images were globally normalized and anatomically standardized to the standard brain shape using Human Brain Atlas (HBA) of Roland et al. and each subject's X-CT. Then, mean and SD images were calculated voxel by voxel. For the next step, 99m Tc-ECD SPECT images of a patient were obtained, and global normalization and anatomical standardization were performed as the same way. Then, a statistical map was calculated as following voxel by voxel; (P-Mean)/SDx10+50, where P, mean and SD indicate voxel value of patient, mean and SD images of normal databases, respectively. We found this statistical map was helpful for clinical diagnosis of brain SPECT studies. (author)

  4. Comparison with myocardial perfusion MRI and myocardial perfusion SPECT in the diagnostic performance of coronary artery disease. A meta-analysis

    International Nuclear Information System (INIS)

    Iwata, Kunihiro; Kubota, Makoto; Ogasawara, Katsuhiko

    2008-01-01

    We compared the diagnostic abilities of stress myocardial perfusion MRI (myocardial perfusion MRI) and myocardial perfusion single photon emission computed tomography (SPECT), using a meta-analysis method. We investigated the diagnostic abilities of MRI and SPECT in similar subject groups in reports written in English or Japanese. The reports to be used for analysis were selected according to a ''screening standard,'' which was established in advance. After consolidating the data from the selected reports, we compared the integrated odds ratio, the point estimation values of sensibility/specificity, and the summary receiver operating characteristic (ROC) curve. For the analysis, six reports were selected (subjects: 153, coronary-artery target sites: 447). Meta-analysis revealed that the diagnostic ability of myocardial perfusion MRI was superior to that of myocardial perfusion SPECT regarding each of the parameters. This is considered to be supportive evidence of the usefulness of myocardial perfusion MRI. (author)

  5. Agreement of left ventricular ejection fraction and volumes between adenosine stress TL-201 gated SPECT and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S. [College of Medicine, Univ. of Ewha, Seoul (Korea, Republic of); Moon, D. H.; Kim, H. M.; Yang, Y. J.; Kang, D. H. [Asan Medical Center, Seoul (Korea, Republic of)

    2003-07-01

    Electrocardiogram-gated TI-201 SPECT measurements of left ventricular ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) have shown high correlation with conventional methods. However, how much these parameters measured by TI-201 gated SPECT differ from those by echocardiography has not been assessed. Adenosine stress (Ad-G) and redistribution TI-201 gated SPECT (Re-G) and resting echocardiography were conducted in 337 patients (184 male, 153 female). EDV, ESV and LVEF measured by QGS software were compared with the results by echocardiography. Patients with arrhythmia (atrial fibrillation or frequent premature contractions) or evidence of fixed or reversible perfusion defects on TI-201 SPECT were excluded. EF, EDV and ESV measured by Ad-G (63.3{+-}9.8,73.8{+-}30.2,29.1{+-}20.1) and Re-G (65.2{+-}11.6,69.1{+-}30.1,26.5{+-}20.3) correlated well with those by Echo (61.4{+-}7.9,78.3{+-}2.7, 30.7{+-} 17.5 ; r of Ad-G=0.547, 0.850, 0.827, p<0.001 ; r of Re-G=0.585, 0.838, 0.819, p<0.001). However the difference (mean, SD, SEE of Echo - gated SPECT) was statistically significant (EF: Ad-G=1.71, 8.92, 0.48, Re-G=3.59, 10.39, 0.56, p<0.001 ; EDV: Ad-G=4.75, 16.21, 0.88, Re-G=9.53, 16.77, 0.91, p<0.001 ; ESV: Ad-G=1.75, 11.35, 0.61, p<0.05, Re-G=4.29, 11.7, 0.63, p<0.001). Bland-Altman plots showed that the difference of EDV and ESV did not vary in any systematic way over the range of measurement, whereas the difference of EF increased with increasing average EF by Echo and gated-SPECT. The difference of EF, EDV, and ESV between Ad-G and Echo was significantly smaller than those between Re-G and Echo (p<0.001). Gated TI-201 SPECT underestimates EDV and ESV over a wide range of volume. As a result, EF by gated TI-201 SPECT is overestimated especially in patients with small LV volume. Ad-G is preferable to Re-G in assessing left ventricular ejection fraction and volume in place of Echo because of smaller bias.

  6. Salivary SPECT and factor analysis in Sjoegren's syndrome

    International Nuclear Information System (INIS)

    Nakamura, T.; Oshiumi, Y.; Yonetsu, K.; Muranaka, T.; Sakai, K.; Kanda, S.; National Fukuoka Central Hospital

    1991-01-01

    Salivary SPECT and factor analysis in Sjoegren's syndrome were performed in 17 patients and 6 volunteers as controls. The ability of SPECT to detect small differences in the level of uptake can be used to separate glands from background even when uptake is reduced as in the patients with Sjoegren's syndrome. In control and probable Sjoegren's syndrome groups the uptake ratio of the submandibular gland to parotid gland on salivary SPECT (S/P ratio) was less than 1.0. However, in the definite Sjoergren's syndrome group, the ratio was more than 1.0. Moreover, the ratio in all patients with sialectasia, which is characteristic of Sjoegren's syndrome, was more than 1.0. Salivary factor analysis of normal parotid glands showed slowly increasing patterns of uptake and normal submandibular glands had rapidly increasing patterns of uptake. However, in the definite Sjoegren's syndrome group, the factor analysis patterns were altered, with slowly increasing patterns dominating both in the parotid and submandibular glands. These results suggest that the S/P ratio in salivary SPECT and salivary factor analysis provide additional radiologic criteria in diagnosing Sjoegren's syndrome. (orig.)

  7. Evaluation of left ventricular ejection fraction using quantitative gated SPECT (QGS)

    International Nuclear Information System (INIS)

    Musa, M. A. A.

    2010-07-01

    Electrocardiographic ally gated myocardial perfusion SPECT (G SPECT) is a state-of the art technique for the combined evaluation of myocardial perfusion and left ventricular function within a single study. It is currently one of the most commonly performed cardiology procedures in a nuclear medicine department. Automation of the image processing and quantification has made this techniques highly reproducible, practical and user friendly in the clinical setting . In patients with coronary artery disease, gating enhances the diagnostic and prognostic capability of myocardial perfusion imaging provides incremental information over the the perfusion data, and has shown potentials for myocardial viability assessment and sequential follow-up after therapy. Evaluation of the left ventricular (L V) function is important in clinical cardiology. Quantifying the degree and extent of the L V functional abnormalities permits a systematic assessment of the disease process on the myocardial performance. The aim of this thesis is to evaluate left ventricular ejection fraction (LVEF) in patients with no evidence of ischemic response during the stress test. This investigation was carried out in view of the few reports concerning the findings ventricular function with gated SPECT in these situations in the normal population, which is relevant when considering the possibility of myocardial stunning. Method: We prospectively studied 30 selected patients, in difference age and gender. A one-day protocol was used, with injection 555 MBq - 1.11 MBq (15 - 30 mCi) of 99 mTc-M1 B1 at stress and rest. Gated perfusion SPECT was acquired 30 to 60 minutes after radiotracer injection in both condition and processed using QGSPECT software. Difference between stress and rest LVEF was calculated. Result and conclusion: rest LVEF was higher in the stress (exercise) group, A trend line was done in both groups and r-value was (0.9) and p=0.04 in acceptance value. Standard deviation of LVEF also was

  8. Motor activation SPECT for the neurosurgical diseases. Examination protocol and basic study

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-07-01

    We examined and analyzed the region activated by the unilateral finger opposition task using motor activation single photon emission computed tomography (M-SPECT). M-SPECT studies were carried out on 11 cases, all of whom were normal volunteers (mean age: 49.4 years), none of whom showed any abnormal findings on magnetic resonance images (MRIs) or any neurological abnormalities. The SPECT images for each case were superimposed on the MRIs using Image Fusion Software. The result of the M-SPECT study was expressed as positive or negative. The cases with a marked increase of blood flow in the sensori-motor cortex during the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among 11 patients, 10 cases (90.9%) showed positive M-SPECT findings, and the eleventh case showed negative M-SPECT findings. The asymmetry index (AI) was calculated on the sensorio-motor cortex in the SPECT images before and after motor activation, with the 10 cases with positive M-SPECT having an AI before motor activation of 0.99{+-}0.06 (mean{+-}standard deviation) and an AI after motor activation of 1.14{+-}0.07. This change was statistically significant (p<0.05). In the single case categorized as negative, the AI before motor activation was 1.04, and the AI after motor activation was 1.01. There was no significant difference of AI values between the resting and motor activation stages. The positive M-SPECT was seen in 90.9% of the normal volunteer series using a visual inspection method. In these cases, the blood flow in the sensorio-motor cortex significantly increased after application of the finger opposition task using the semi-quantitative method. (author)

  9. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    International Nuclear Information System (INIS)

    Bowsher, James; Giles, William; Yin, Fang-Fang; Yan, Susu; Roper, Justin

    2014-01-01

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min

  10. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Bowsher, James, E-mail: james.bowsher@duke.edu; Giles, William; Yin, Fang-Fang [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710 (United States); Yan, Susu [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710 (United States); Roper, Justin [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2014-01-15

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min

  11. SPECT/CT: main applications in nuclear medicine

    International Nuclear Information System (INIS)

    Perera Pintado, Alejandro; Torres Aroche, Leonel A.; Vergara Gil, Alex; Batista Cuéllar, Juan F.; Prats Capote, Anaís

    2017-01-01

    SPECT/CT has represented not only the possibility of acquiring anatomical and functional images in one single study, but also a revolution for the clinical management of several diseases, taking the better of each one of these imaging modalities. The present work is aimed at presenting an overview of the most important applications of the SPECT/CT in the field of oncology, cardiology and neurology. New technological advances in the design of innovative solid state detectors and related equipment have had a positive effect on the performance of this kind of dual modality. This hybrid technique improves the sensitivity and the specificity of gammagraphic studies, as well as shortens the acquisition times and gives attenuation correction of co-registered images, which, in turn, makes their analysis easier. Some of the main applications for the study of oncological diseases are the following: localization and follow-up of different kinds of tumors, their metastasis and relapses, as well as the optimization of radiotherapy doses. This technique has been useful to evaluate the coronary artery disease allowing an adequate attenuation correction of images, the determination of calcium score, and performing angio-CT studies, according to the CT quality. SPECT/CT has also gained ground in the assessment of some neurological diseases. Conclusions: The introduction of new technological advances and radiopharmaceuticals thus predicting a more relevant place for SPECT/CT in clinical practice. (author)

  12. Comparison of SPECT bone scintigraphy with MRI for diagnosis of meniscal tears

    International Nuclear Information System (INIS)

    Tahmasebi, Mohammad-naghi; Saghari, Mohsen; Moslehi, Masoud; Gholamrezanezhad, Ali

    2005-01-01

    Scintigraphy has been considered as competitive to MRI, but limited data are available on the accuracy of single photon emission tomography (SPECT) compared with MRI for the assessment of meniscal tears. Our objective was to assess the value of SPECT in comparison to MRI. Between January 2003 and March 2004, sixteen patients were studied with both modalities and the accuracy rates of SPECT scan results, and MRI findings in the diagnosis of meniscal tears were compared. Arthroscopy was the gold standard. The respective sensitivity rate, specificity rate, and positive and negative predictive accuracies of MRI were 89%, 94%, 93%, and 79% and for SPECT those were 78%, 94%, 94%, and 88%. There was good agreement on the presence or absence of tears between two modalities (κ statistic = 0.699). SPECT and MRI are both valuable imaging techniques. SPECT is a useful alternative when MRI is unavailable or unsuitable and it is beneficial when more possible accuracy is desired (such as when MRI results are either inconclusive or conflict with other clinical data)

  13. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  14. Absolute quantitative total-body small-animal SPECT with focusing pinholes

    International Nuclear Information System (INIS)

    Wu, Chao; Have, Frans van der; Vastenhouw, Brendan; Beekman, Freek J.; Dierckx, Rudi A.J.O.; Paans, Anne M.J.

    2010-01-01

    In pinhole SPECT, attenuation of the photon flux on trajectories between source and pinholes affects quantitative accuracy of reconstructed images. Previously we introduced iterative methods that compensate for image degrading effects of detector and pinhole blurring, pinhole sensitivity and scatter for multi-pinhole SPECT. The aim of this paper is (1) to investigate the accuracy of the Chang algorithm in rodents and (2) to present a practical Chang-based method using body outline contours obtained with optical cameras. Here we develop and experimentally validate a practical method for attenuation correction based on a Chang first-order method. This approach has the advantage that it is employed after, and therefore independently from, iterative reconstruction. Therefore, no new system matrix has to be calculated for each specific animal. Experiments with phantoms and animals were performed with a high-resolution focusing multi-pinhole SPECT system (U-SPECT-II, MILabs, The Netherlands). This SPECT system provides three additional optical camera images of the animal for each SPECT scan from which the animal contour can be estimated. Phantom experiments demonstrated that an average quantification error of -18.7% was reduced to -1.7% when both window-based scatter correction and Chang correction based on the body outline from optical images were applied. Without scatter and attenuation correction, quantification errors in a sacrificed rat containing sources with known activity ranged from -23.6 to -9.3%. These errors were reduced to values between -6.3 and +4.3% (with an average magnitude of 2.1%) after applying scatter and Chang attenuation correction. We conclude that the modified Chang correction based on body contour combined with window-based scatter correction is a practical method for obtaining small-animal SPECT images with high quantitative accuracy. (orig.)

  15. Clinical usefulness of hyperventilation-loaded SPECT in coronary artery disease

    International Nuclear Information System (INIS)

    Taya, Makoto

    1994-01-01

    The purpose of this study was twofold: (1) to assess the clinical usefulness of hyperventilation-loaded Tl-201 myocardial single photon emission computed tomography (HV-SPECT) in detecting coronary spasm; and (2) to correlate coronary spasm with ischemic heart diseases. A total of 138 patients were examined. They were divided into Group 1 of a total of 69 patients with chest pain at rest, consisting of 25 with vasospastic angina and 44 with atypical chest pain; Group 2 of 37 patients with angina pectoris; and Group 3 of 32 patients with myocardial infarction. In Group I, HV-SPECT was positive in 96% (24/25) for vasospastic angina and 50% (22/44) for atypical angina pectoris. When thallium defect scores 2 or more were interpreted as a decreased thallium uptake, Tl-201 HV-SPECT had a sensitivity of 72%, a specificity of 93%, and an accuracy of 85.6% in diagnosing vasospastic angina. In Group 2, HV-SPECT showed a significantly higher positive rate in patients with resting angina pectoris than those with effort angina pectoris (69% vs 22%). In Group 3, HV-SPECT was a positive rate of 53%. When Nifedipine was administered, the positive cases turned to be negative in 47%. HV-SPECT proved to be useful as a noninvasive method for diagnosing coronary spasm. Coronary spasm was suggested to be present in ischemic heart disease other than vasospastic angina and atypical chest pain. (N.K.)

  16. Filters in 2D and 3D Cardiac SPECT Image Processing

    Directory of Open Access Journals (Sweden)

    Maria Lyra

    2014-01-01

    Full Text Available Nuclear cardiac imaging is a noninvasive, sensitive method providing information on cardiac structure and physiology. Single photon emission tomography (SPECT evaluates myocardial perfusion, viability, and function and is widely used in clinical routine. The quality of the tomographic image is a key for accurate diagnosis. Image filtering, a mathematical processing, compensates for loss of detail in an image while reducing image noise, and it can improve the image resolution and limit the degradation of the image. SPECT images are then reconstructed, either by filter back projection (FBP analytical technique or iteratively, by algebraic methods. The aim of this study is to review filters in cardiac 2D, 3D, and 4D SPECT applications and how these affect the image quality mirroring the diagnostic accuracy of SPECT images. Several filters, including the Hanning, Butterworth, and Parzen filters, were evaluated in combination with the two reconstruction methods as well as with a specified MatLab program. Results showed that for both 3D and 4D cardiac SPECT the Butterworth filter, for different critical frequencies and orders, produced the best results. Between the two reconstruction methods, the iterative one might be more appropriate for cardiac SPECT, since it improves lesion detectability due to the significant improvement of image contrast.

  17. Precise fusion of MRI and dual energy 111In WBC/99mTc HDP SPECT/CT in the diabetic foot using companion CT: an example of SPECT/MRI imaging

    International Nuclear Information System (INIS)

    Knešaurek, K.; Heiba, S.; Kolker, D.; Vatti, S.

    2015-01-01

    The purpose of our study was to correctly fuse MRI and SPECT 111 In WBC and 99m Tc HDP images using companion CT images. The fused images could be used to assess proper surgical approach in treatment of the diabetic foot. Nine patients who had dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT and MRI studies within a week were investigated in an ongoing project. A GE Infinia SPECT/CT camera and Siemens MAGNETOM 1.5T MR system were used in this study. First, the MRI and corresponding CT images were coregistrated using a transformation based on normalized mutual information. The transformation was saved and used for MRI and 111 In WBC/ 99 m Tc HDP SPECT fusion. A Jaszczak phantom study was also performed in order to estimate accuracy of MRI/ SPECT fusion. The Jaszczak phantom study with 3.7 MBq 111 In hot sphere showed that MRI/SPECT alignment using the approach described above produced registration with 0.7±0.4 mm accuracy in all three dimensions (3D). The nine clinical cases were visually evaluated and showed 1-2 mm 3D fusion accuracy. MRI provides almost perfect anatomy of soft tissue and bony structures but it may exaggerate the extent of infection. 111 In WBC/ 99 m Tc HDP SPECT imaging is more accurate for infection detection but lacks anatomical reference. Combination of these images proved an essential adjunct to diagnosis. A clinical utility of the approach is illustrated in two clinical examples. In conclusion, the CT in dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT studies can be used to accurately fuse and compare 111 In WBC/ 99 m Tc HDP SPECT and MRI images of the diabetic foot. This can significantly help in conservative treatment planning and limb salvage procedures in treatment of diabetic foot infections.

  18. Brain SPECT imaging in temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Krausz, Y.; Yaffe, S.; Atlan, H.; Cohen, D.; Konstantini, S.; Meiner, Z.

    1991-01-01

    Temporal lobe epilepsy is diagnosed by clinical symptoms and signs and by localization of an epileptogenic focus. A brain SPECT study of two patients with temporal lobe epilepsy, using 99m Tc-HMPAO, was used to demonstrate a perfusion abnormality in the temporal lobe, while brain CT and MRI were non-contributory. The electroencephalogram, though abnormal, did not localize the diseased area. The potential role of the SPECT study in diagnosis and localization of temporal lobe epilepsy is discussed. (orig.)

  19. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Nuutinen, Juho; Liu, Yawu; Laakso, Mikko P.; Karonen, Jari O.; Vanninen, Esko J.; Kuikka, Jyrki T.; Aronen, Hannu J.; Vanninen, Ritva L.

    2009-01-01

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and 99m Tc-labeled ethylcysteinate dimer ( 99m Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. 99m TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  20. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nuutinen, Juho [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Liu, Yawu; Laakso, Mikko P. [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland); Karonen, Jari O. [Mikkeli Central Hospital, Department of Radiology, Mikkeli (Finland); Vanninen, Esko J. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Kuikka, Jyrki T. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Niuvanniemi Hospital, Kuopio (Finland); Aronen, Hannu J. [University of Turku, Department of Radiology, Turku (Finland); Vanninen, Ritva L. [Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland)

    2009-10-15

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and {sup 99m}Tc-labeled ethylcysteinate dimer ({sup 99m}Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. {sup 99m}TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  1. Mnemonic activation by SPECT; Activation mnesique en TEMP

    Energy Technology Data Exchange (ETDEWEB)

    Migneco, O.; Darcourt, J.; Benoit, M; Malandain, G.; Thirion, J.P.; Robert, Ph.; Vidal, R.; Desvignes, Ph.; Benoliel, J.; Ayache, N.; Bussiere, F. [Universite de Nice Sophia-Antipolis, INRIA (France)

    1997-12-31

    Data of literature show that SPECT is able to detect cerebral activations induced by sensory-motor stimuli. The facts are not clearly established in what concerns the cognitive activations the amplitude of which is lower. We have studied an activation paradigm such as the Grober and Bruschke test which implies the long term explicit memory. It comprises a visual presentation of words followed by their indexed recall. By using a two-day protocol, 2 SPECTs were achieved in 4 healthy right-handed voluntaries as follows: one of activation (A) and one of control (B). The fifth subject benefited by a SPECT B and of an MRI. The injection for the examination A has been done during the indexed recall stage and for the examination B at the moment when the patient repeated several times the same 3 words. The SPECT data were collected 1 hour after the injection of 370 MBq of ECD making use of a 3-head camera equipped with UHR fan collimators and ending by a LMH on the reconstructed images of 8 mm. The MRI has been achieved by means of a Signa 1.5 Tesla magnet. The SPECT A and B of the subjects 1 to 4 were matched elastically to that of the subject 5 and that of the subject 5 was rigidly matched on its MRI. In this way the individual activation cards of the 4 subjects could be averaged and superimposed on the MRI of the 5. subject. One observes an internal temporal activation (maximal activation of left tonsil, +25% and right uncus, +23%) and a right cingulum activation (maximal activation, +25%), in agreement with the neuro-physiological data. The elastic matching makes possible the inter-subject averaging, what increases the signal-to-noise ratio of activation. The inter-modality rigid matching facilitates the anatomical localisation of the activation site. With these adapted tools, the cognitive activation is thus possible by SPECT and opens perspectives for early diagnosis of neurological troubles, namely of Alzheimer`s disease

  2. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  3. SPECT versus planar scintigraphy for quantification of splenic sequestration of 111In-labelled platelets

    International Nuclear Information System (INIS)

    Savolainen, S.; Helsinki Univ. Central Hospital

    1992-01-01

    The splenic uptake of thrombocytes and spleen size were studied in 25 patients with idiopathic thrombocytopenic purpura (ITP) using two methods: anterior/posterior scintigraphy and single photon emission computed tomography (SPECT). Various factors (acquisition and reconstruction protocols) influencing the quality of 111 In SPECT were studied. The splenic uptake, measured by SPECT, was found to be significantly higher in patients with a high level of autoantibodies in the blood than in patients without such antibodies. The correlation between the spleen SPECT volume and the geometric mean size calculated as geometric mean of anterior and posterior images differed by more than 50% from the SPECT volume in some patients. Based on these observations and on the results of phantom studies, it is concluded that a reasonable estimate of the spleen:liver uptake ratio may be obtained using planar imaging, but to estimate the spleen volume and the absolute splenic uptake of platelets SPECT imaging is needed, in spite of the present technical limitations of SPECT. (Author)

  4. Benign versus malignant osseous lesions in spine: differentiation by means of bone SPECT/CT fused image

    International Nuclear Information System (INIS)

    Yao Zhiming; Qu Wanying

    2004-01-01

    This study compared the efficiency of SPECT-CT fused image with planar bone scan, bone SPECT and CT in differentiating malignant from benign lesions and detecting metastases to the spine. Methods. Total 144 patients with spinal lesions underwent planar bone scan (WB), single photon tomography (SPECT), CT and SPECT-CT fused image by a SPECT/CT system. The malignant or benign nature of lesions was proved by radiological Methods, histological findings, 6-24 month follow-up, or all of these. The diagnostic results was divided into 4 types, i.e., normal, benign, doubtful malignant and malignant. Results. There were 137 malignant and 252 benign lesions in 144 patients, respectively. The percentages of doubtful malignant diagnosed by WB, SPECT, CT and fused image are 22.6%, 5.1%, 9.5% and 0%, respectively, p < 0.01-0.001, except for the comparison between the percentages of SPECT and CT. Sensitivities in detection of malignant lesions by WB, SPECT, CT and fused image are 75.2%, 94.2%, 96.6% and 99.3%, respectively, P < 0.001, excepting for the comparisons between those of SPECT and CT, and between those of CT and fused image. The sensitivities m detection of benign lesions by WB, SPECT, CT and fused image are, 56.7%, 86.5%, 90.1% and 96.8%, respectively, P < 0.005 - 0.001, excepting for the comparison between those of SPECT and CT. The specificities in detection of maliganant lesions by WB, SPECT, CT and fused image are 70.6%, 88.9%, 97.2% and 97.6%, respectively, P < 0.001, excepting for the comparison between those of CT and fused image. Conclusion. Bone SPECT-CT fused image has highest diagnostic and differentiating diagnostic values in detection of spinal abnormalities over the planar bone scanning and SPECT. The CT by present SPECT/CT system can complement planar bone scanning and SPECT and is clinically valuable in detection of spinal abnormalities. (authors)

  5. Brain SPECT in severs traumatic head injury

    International Nuclear Information System (INIS)

    Beaulieu, F.; Eder, V.; Pottier, J.M.; Baulieu, J.L.; Fournier, P.; Legros, B.; Chiaroni, P.; Dalonneau, M.

    2000-01-01

    The aim of this work was to compare the results of the early brain scintigraphy in traumatic brain injury to the long term neuropsychological behavior. Twenty four patients had an ECD-Tc99m SPECT, within one month after the trauma; scintigraphic abnormalities were evaluated according to a semi-quantitative analysis. The neuropsychological clinical investigation was interpreted by a synthetic approach to evaluate abnormalities related to residual motor deficit, frontal behavior, memory and language disorders. Fourteen patients (58%) had sequela symptoms. SPECT revealed 80 abnormalities and CT scan only 31. Statistical analysis of uptake values showed significantly lower uptake in left basal ganglia and brain stem in patients with sequela memory disorders. We conclude that the brain perfusion scintigraphy is able to detect more lesions than CT and that it could really help to predict the neuropsychological behavior after severe head injury. Traumatology could become in the future a widely accepted indication of perfusion SPECT. (authors)

  6. Pinhole SPECT: high resolution imaging of brain tumours in small laboratory animals

    International Nuclear Information System (INIS)

    Franceschim, M.; Bokulic, T.; Kusic, Z.; Strand, S.E.; Erlandsson, K.

    1994-01-01

    The performance properties of pinhole SPECT and the application of this technology to evaluate radionuclide uptake in brain in small laboratory animals were investigated. System sensitivity and spatial resolution measurements of a rotating scintillation camera system were made for a low energy pinhole collimator equipped with 2.0 mm aperture pinhole insert. Projection data were acquired at 4 degree increments over 360 degrees in the step and shoot mode using a 4.5 cm radius of rotation. Pinhole planar and SPECT imaging were obtained to evaluate regional uptake of Tl-201, Tc-99m-MIBI, Tc-99m-HMPAO and Tc-99m-DTPA in tumor and control regions of the brain in a primary brain tumor model in Fisher 344 rats. Pinhole SPECT images were reconstructed using a modified cone- beam algorithm developed from a two dimensional fan-beam filtered backprojection algorithm. The reconstructed transaxial resolution of 2.8 FWHM and system sensitivity of 0.086 c/s/kBq with the 2.0 mm pinhole collimator aperture were measured. Tumor to non-tumor uptake ratios at 19-28 days post tumor cell inoculation varied by a factor > 20:1 on SPECT images. Pinhole SPECT provides an important new approach for performing high resolution imaging: the resolution properties of pinhole SPECT are superior to those which have been achieved with conventional SPECT or PET imaging technologies. (author)

  7. Evidence for tankyrases as antineoplastic targets in lung cancer

    International Nuclear Information System (INIS)

    Busch, Alexander M; Johnson, Kevin C; Stan, Radu V; Sanglikar, Aarti; Ahmed, Yashi; Dmitrovsky, Ethan; Freemantle, Sarah J

    2013-01-01

    New pharmacologic targets are urgently needed to treat or prevent lung cancer, the most common cause of cancer death for men and women. This study identified one such target. This is the canonical Wnt signaling pathway, which is deregulated in cancers, including those lacking adenomatous polyposis coli or β-catenin mutations. Two poly-ADP-ribose polymerase (PARP) enzymes regulate canonical Wnt activity: tankyrase (TNKS) 1 and TNKS2. These enzymes poly-ADP-ribosylate (PARsylate) and destabilize axin, a key component of the β-catenin phosphorylation complex. This study used comprehensive gene profiles to uncover deregulation of the Wnt pathway in murine transgenic and human lung cancers, relative to normal lung. Antineoplastic consequences of genetic and pharmacologic targeting of TNKS in murine and human lung cancer cell lines were explored, and validated in vivo in mice by implantation of murine transgenic lung cancer cells engineered with reduced TNKS expression relative to controls. Microarray analyses comparing Wnt pathway members in malignant versus normal tissues of a murine transgenic cyclin E lung cancer model revealed deregulation of Wnt pathway components, including TNKS1 and TNKS2. Real-time PCR assays independently confirmed these results in paired normal-malignant murine and human lung tissues. Individual treatments of a panel of human and murine lung cancer cell lines with the TNKS inhibitors XAV939 and IWR-1 dose-dependently repressed cell growth and increased cellular axin 1 and tankyrase levels. These inhibitors also repressed expression of a Wnt-responsive luciferase construct, implicating the Wnt pathway in conferring these antineoplastic effects. Individual or combined knockdown of TNKS1 and TNKS2 with siRNAs or shRNAs reduced lung cancer cell growth, stabilized axin, and repressed tumor formation in murine xenograft and syngeneic lung cancer models. Findings reported here uncovered deregulation of specific components of the Wnt pathway in both

  8. Technetium-99m-HMPAO SPECT, CT and MRI in the evaluation of patients with chronic traumatic brain injury: a correlation with neuropsychological performance.

    Science.gov (United States)

    Ichise, M; Chung, D G; Wang, P; Wortzman, G; Gray, B G; Franks, W

    1994-02-01

    The purposes of this study were: (1) to compare 99mTc-hexamethylpropyleneamineoxime (HMPAO) SPECT with CT and MRI in chronic traumatic brain injury (TBI) patients and (2) to correlate both functional and structural neuroimaging measurements of brain damage with neuropsychological (NP) performance. Twenty-nine patients (minor TBI, n = 15 and major TBI, n = 14) and 17 normal controls (NC) underwent HMPAO SPECT, CT, MRI and NP testing. Imaging data were analyzed both visually and quantitatively. Nineteen (66%) patients showed 42 abnormalities on SPECT images, whereas 13 (45%) and 10 (34%) patients showed 29 abnormalities on MRI and 24 abnormalities on CT. SPECT detected relatively more abnormalities than CT or MRI in the minor TBI subgroup. The TBI group showed impairment on 11 tests for memory, attention and executive function. Of these, the anterior-posterior ratio (APR) correlated with six tests, whereas the ventricle-to-brain ratio (VBR), a known structural index of a poor NP outcome, correlated with only two tests. In evaluating chronic TBI patients, HMPAO SPECT, as a complement to CT or MRI, may play a useful role by demonstrating brain dysfunction in morphologically intact brain regions and providing objective evidence for some of the impaired NP performance.

  9. Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging

    International Nuclear Information System (INIS)

    Magota, Keiichi; Kubo, Naoki; Kuge, Yuji; Nishijima, Ken-ichi; Zhao, Songji; Tamaki, Nagara

    2011-01-01

    We investigated the performance of the Inveon small-animal PET/SPECT/CT system and compared the imaging capabilities of the SPECT and PET components. For SPECT, the energy resolution, tomographic spatial resolution and system sensitivity were evaluated with a 99m Tc solution using a single pinhole collimator. For PET, the spatial resolution, absolute sensitivity, scatter fraction and peak noise equivalent count were evaluated. Phantoms and a normal rat were scanned to compare the imaging capabilities of SPECT and PET. The SPECT spatial resolution was 0.84 mm full-width at half-maximum (FWHM) at a radius of rotation of 25 mm using a 0.5-mm pinhole aperture collimator, while the PET spatial resolution was 1.63 mm FWHM at the centre. The SPECT system sensitivity at a radius of rotation of 25 mm was 35.3 cps/MBq (4 x 10 -3 %) using the 0.5-mm pinhole aperture, while the PET absolute sensitivity was 3.2% for 350-650 keV and 3.432 ns. Accordingly, the volume sensitivity of PET was three orders of magnitude higher than that of SPECT. This integrated PET/SPECT/CT system showed high performance with excellent spatial resolution for SPECT and sensitivity for PET. Based on the tracer availability and system performance, SPECT and PET have complementary roles in multimodality small-animal imaging. (orig.)

  10. Support vector machine-based classification of neuroimages in Alzheimer’s disease: direct comparison of FDG-PET, rCBF-SPECT and MRI data acquired from the same individuals

    Directory of Open Access Journals (Sweden)

    Luiz K. Ferreira

    2017-10-01

    Full Text Available Objective: To conduct the first support vector machine (SVM-based study comparing the diagnostic accuracy of T1-weighted magnetic resonance imaging (T1-MRI, F-fluorodeoxyglucose-positron emission tomography (FDG-PET and regional cerebral blood flow single-photon emission computed tomography (rCBF-SPECT in Alzheimer’s disease (AD. Method: Brain T1-MRI, FDG-PET and rCBF-SPECT scans were acquired from a sample of mild AD patients (n=20 and healthy elderly controls (n=18. SVM-based diagnostic accuracy indices were calculated using whole-brain information and leave-one-out cross-validation. Results: The accuracy obtained using PET and SPECT data were similar. PET accuracy was 68∼71% and area under curve (AUC 0.77∼0.81; SPECT accuracy was 68∼74% and AUC 0.75∼0.79, and both had better performance than analysis with T1-MRI data (accuracy of 58%, AUC 0.67. The addition of PET or SPECT to MRI produced higher accuracy indices (68∼74%; AUC: 0.74∼0.82 than T1-MRI alone, but these were not clearly superior to the isolated neurofunctional modalities. Conclusion: In line with previous evidence, FDG-PET and rCBF-SPECT more accurately identified patients with AD than T1-MRI, and the addition of either PET or SPECT to T1-MRI data yielded increased accuracy. The comparable SPECT and PET performances, directly demonstrated for the first time in the present study, support the view that rCBF-SPECT still has a role to play in AD diagnosis.

  11. Single photon emission computerized tomography (SPECT)

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as 123 I and 99 Tc m that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  12. Single photon emission computerized tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as {sup 123}I and {sup 99}Tc{sup m} that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  13. Is SPECT useful in imaging of abdominal inflammatory processes using 99mTc-HMPAO-WBCs?

    International Nuclear Information System (INIS)

    Smole, M.S.; Stantic, T.S.; Fettich, J.F.

    2002-01-01

    Aim: The aim of the study is to determine whether SPECT gives additional information in the assessment of inflammation of the abdominal region with labelled white blood cells as compared with usual planar imaging. Patients And Methods: SPECT and planar imaging was performed in 26 patients with suspected inflammatory process in the abdomen, within three hours after injection of autologous white blood cells labelled with 99m Tc HMPAO. Planar images where acquired as static spot images using high resolution low energy collimator on 256 x 256 matrix. SPECT was performed using the same collimator on 128 x 128 matrix in 128 projections. Filtered back projection was used for reconstruction and volume rendering was performed. Results: The lesions in the abdomen were classified as jejunum, colon ascendents, colon transversum, colon descendents, sigmoid, and lesions outside GIT. All lesions, which were seen on planar images, except one, were also seen on SPECT. Five equivocal lesions seen on planar images were reconfirmed as pathological on SPECT. Additionally SPECT revealed three lesions not seen on planar images. Fourteen lesions were seen by both imaging techniques. All together SPECT improved diagnostic accuracy of 99m Tc - HMPAO - WBC scintigraphy in 7/28 patients. Conclusion: more inflammatory lesions in the abdomen are revealed by SPECT and volume rendering, than by planar imaging equivocal lesions seen on planar images can be characterised as positive or negative by SPECT. SPECT artefacts can cause possible false positive results; therefore usual planar imaging cannot be omitted if SPECT is performed

  14. [CT-Screening for Lung Cancer - what is the Evidence?

    Science.gov (United States)

    Watermann, Iris; Reck, Martin

    2018-04-01

    In patients with lung cancer treatment opportunities and prognosis are correlated to the stage of disease with a chance for curative treatment in patients with early stage disease. Therefore, early detection of lung cancer is of paramount importance for improving the prognosis of lung cancer patients.The National Lung Screening Trial (NLST) has already shown that low-dose CT increases the number of identified early stage lung cancer patients and reduces lung cancer related mortality. Critically considered in terms of CT-screening are false-positive results, overdiagnosis and unessential invasive clarification. Preliminary results of relatively small European trials haven´t yet confirmed the results of the NLST-study.Until now Lung Cancer Screening by low dose CT-scan or other methods is neither approved nor available in Germany.To improve the efficacy of CT-Screening and to introduce early detection of lung cancer in standard practice, additional, complementing methods should be further evaluated. One option might be the supplementary analysis of biomarkers in liquid biopsies or exhaled breath condensates. In addition, defining the high-risk population is of great relevance to identify candidates who might benefit of early detection programs. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Scatter and attenuation correction in SPECT

    International Nuclear Information System (INIS)

    Ljungberg, Michael

    2004-01-01

    The adsorbed dose is related to the activity uptake in the organ and its temporal distribution. Measured count rate with scintillation cameras is related to activity through the system sensitivity, cps/MBq. By accounting for physical processes and imaging limitations we can measure the activity at different time points. Correction for physical factor, such as attenuation and scatter is required for accurate quantitation. Both planar and SPECT imaging can be used to estimate activities for radiopharmaceutical dosimetry. Planar methods have been the most widely used but is a 2D technique. With accurate modelling for imagine in iterative reconstruction, SPECT methods will prove to be more accurate

  16. A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in (131)I SPECT.

    Science.gov (United States)

    Dewaraja, Yuni K; Ljungberg, Michael; Majumdar, Amitava; Bose, Abhijit; Koral, Kenneth F

    2002-02-01

    This paper reports the implementation of the SIMIND Monte Carlo code on an IBM SP2 distributed memory parallel computer. Basic aspects of running Monte Carlo particle transport calculations on parallel architectures are described. Our parallelization is based on equally partitioning photons among the processors and uses the Message Passing Interface (MPI) library for interprocessor communication and the Scalable Parallel Random Number Generator (SPRNG) to generate uncorrelated random number streams. These parallelization techniques are also applicable to other distributed memory architectures. A linear increase in computing speed with the number of processors is demonstrated for up to 32 processors. This speed-up is especially significant in Single Photon Emission Computed Tomography (SPECT) simulations involving higher energy photon emitters, where explicit modeling of the phantom and collimator is required. For (131)I, the accuracy of the parallel code is demonstrated by comparing simulated and experimental SPECT images from a heart/thorax phantom. Clinically realistic SPECT simulations using the voxel-man phantom are carried out to assess scatter and attenuation correction.

  17. 99mTc-ECD brain perfusion SPECT in hyperalgesic fibromyalgia

    International Nuclear Information System (INIS)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Mundler, Olivier; Niboyet, Jean

    2007-01-01

    Neuro-imaging studies with 99m Tc-HMPAO SPECT in fibromyalgia (FM) patients have reported only limited subcortical hypoperfusion. 99m Tc-ECD SPECT is known to provide better evaluation of areas of high cerebral blood flow and regional metabolic rate. We evaluated a homogeneous group of hyperalgesic patients with FM using 99m Tc-ECD SPECT. The aim of this study was to investigate brain processing associated with spontaneous pain in FM patients. Eighteen hyperalgesic FM women (mean age 49 years, range 25-63 years; American College of Rheumatology criteria) and ten healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). Visual Analogue Scale score for pain was 82±4 at the time of the SPECT study. Compared with control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis, with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. In the present study, performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in the sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective-attentional dimension. As current pharmacological and non-pharmacological therapies act differently on the two components of pain, we hypothesise that SPECT could be a valuable and readily available tool to guide individual therapeutic strategy and provide objective follow-up of pain processing recovery under treatment. (orig.)

  18. Multimodality imaging: transfer and fusion of SPECT and MRI data

    International Nuclear Information System (INIS)

    Knesaurek, K.

    1994-01-01

    Image fusion is a technique which offers the best of both worlds. It unites the two basic types of medical images: functional body images(PET or SPECT scans), which provide physiological information, and structural images (CT or MRI), which provide an anatomic map of the body. Control-point based registration technique was developed and used. Tc-99m point sources were used as external markers in SPECT studies while, for MRI and CT imaging only anatomic landmarks were used as a control points. The MRI images were acquired on GE Signa 1.2 system and CT data on a GE 9800 scanner. SPECT studies were performed 1h after intravenous injection of the 740 MBq of the Tc-99m-HMPAO on the triple-headed TRIONIX gamma camera. B-spline and bilinear interpolation were used for the rotation, scaling and translation of the images. In the process of creation of a single composite image, in order to retain information from the individual images, MRI (or CT) image was scaled to one color range and a SPECT image to another. In some situations the MRI image was kept black-and-white while the SPECT image was pasted on top of it in 'opaque' mode. Most errors which propagate through the matching process are due to sample size, imperfection of the acquisition system, noise and interpolations used. Accuracy of the registration was investigated by SPECT-CT study performed on a phantom study. The results has shown that accuracy of the matching process is better, or at worse, equal to 2 mm. (author)

  19. SPECT-CT bone scintigraphy in cancer patients

    International Nuclear Information System (INIS)

    Sergieva, S; Alexandrova, A.; Nikolova, N.; Dimcheva, M.; Baichev, G.

    2012-01-01

    Full text: Introduction: SPECT-CT study allows the precise correlation between functional and morphological data on the same image. Methods: Whole body bone scan (WBBS) is a diagnostic modality still firmly established as a valuable tool to assess skeleton abnormalities. CT is an imaging method for characterizing destruction of the bone spongy lesions, their consolidation or calcium accumulation. This fact allows differentiation of the osteolytic metastases from the osteosclerotic and mixed lesions and also from degenerative ones. Whole body bone scan followed by SPECT-CT scanning increases the accuracy of the study and potentially accelerates the diagnosis of the patient based on a single imaging session. This is especially important in cancer patients. Results and discussion: After retrospectively review of WBBS and SPECT-CT fused images 141 bone lesions in 89 pts were analyzed The skeletal findings with previously uncertain character were classified as definitely benign, indeterminate or definitely malignant. 1. 47 (33%) of all lesions in 36 pts could be correlated with benign degenerative findings on SPECT-CT images. 5 (3%) lesions in 3 of these pts were indeterminate on the SPECT-CT images. They were localized in the area of articulation parts and corpus of the thoracic vertebra and ribs. After additional MRT examination and 6 months follow-up these changes were considered degenerative: osteopathy changes and presence of spondyloarthrosis and osteochondrosis; compression fractures due to advanced osteoporosis. These pts were with prolonged chormono/chemotherapy; chronic inflammatory disease of the coxofemoral articulation, coxarthrosis, aseptic necrosis of the femoral head and postoperative sacroiliitis; post-traumatic fractures or surgical intervention; hyperplastic degenerative lesions in the skeleton and asymmetrical pelvic bone structures due to M. Paget. 2. 41 (28,1%) single osseous metastatic spots (up to 3 foci) were scanned in 31 pts. 3. 13 (10

  20. {sup 67}Ga-SPECT/CT with a hybrid system in the clinical management of lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Palumbo, Barbara; Sivolella, Silvio; Palumbo, Renato [University of Perugia, Nuclear Medicine Section, Department of Radiological Sciences, Perugia (Italy); Palumbo, Isabella; Liberati, Anna Marina [University of Perugia, Internal Medicine and Oncology, Department of Clinical and Experimental Medicine, Perugia (Italy)

    2005-09-01

    The purpose of this study was to investigate the added value of co-registered fusion imaging using a hybrid system in patients with lymphoma. Twenty-four lymphoma patients underwent {sup 67}Ga-SPECT/CT using a hybrid tomograph consisting of a dual-head, variable-angle gamma camera and a low-dose X-ray tube. Results were compared with those of SPECT alone. Forty-five lesions were identified by SPECT alone, while 49 were detected by SPECT/CT. Forty out of the 45 lesions observed on SPECT were confirmed as lymphoma, but five were due to other causes (thoracic aorta blood pool activity, sialoadenitis in the submandibular gland, bowel activity, rib fracture and bone marrow activation due to radiotherapy). SPECT/CT identified nine more neoplastic lesions compared with SPECT alone: four areas of radiopharmaceutical accumulation were observed in para-aortic lymph nodes, three in the spleen, one in the liver and one in para-iliac lymph nodes. In five cases, SPECT/CT provided additional anatomical information over SPECT alone. In four patients, four large areas of {sup 67}Ga uptake (one mediastinal, two supraclavicular and one para-aortic) were better characterised; in one subject uptake was localised in the seventh thoracic vertebra only by SPECT/CT. Hybrid imaging provided additional data in 13 patients (54.2%), thus inducing oncologists to reconsider the therapeutic approach in eight subjects (33.2%): unnecessary treatment was avoided in four (16.6%) while therapy was altered in another four (16.6%). SPECT/CT hybrid system is able to provide information not obtained by SPECT alone. It allows the anatomical localisation of lymphoma and physiological radiopharmaceutical uptake, facilitates the diagnosis of tumours located in the abdomen (subdiaphragmatic lesions) and provides information that may cause a change in therapeutic strategy. (orig.)

  1. The impact of exercise myocardial perfusion SPECT imaging on the selection of patients for coronary angiography

    International Nuclear Information System (INIS)

    Song Liping; He Zuoxiang; Liu Xiujie; Shi Rongfang; Liu Yunzhong; Tian Yueqin; Zhang Xiaoli; Qin Xuewen; Chen Jilin; Gao Runlin

    2001-01-01

    Objective: Exercise 99 Tc m -MIBI myocardial perfusion SPECT is accurate for the diagnosis of coronary artery disease (CAD). This study assessed the impact of exercise myocardial perfusion imaging on the selection of patients for coronary angiography. Methods: 2188 consecutive patients who underwent exercise myocardial perfusion SPECT in authors' department in 1999 were retrospectively analyzed. Among them, 1807 were men, 381 women (average age: 53.5 +- 7.2 years). Overall, exercise myocardial SPECT was normal in 1731 patients, abnormal in 359 cases, and equivocal in 98 patients. There were 141 patients who underwent CAG within 60 days after myocardial SPECT. Results: Overall, 12% of the patients with abnormal SPECT imaging underwent coronary angiography, but only 5% of the patients with a normal SPECT imaging did (P < 0.001). Among these 141 patients who underwent coronary angiography, significant coronary stenosis was present in 91% of the patients who had had an abnormal SPECT imaging, but only 8% of those who had had a normal SPECT imaging (P < 0.001). In those patients who underwent coronary angiography, revascularization rate was 25% for the patients with abnormal SPECT imaging, but only 1% for the patients with a normal SPECT imaging. Conclusion: The results of exercise myocardial perfusion SPECT have a significant impact on the selection of patients for coronary angiography and revascularization

  2. DMSA SPECT imaging using oblique reconstruction in a paediatric population - benefits and technical considerations

    International Nuclear Information System (INIS)

    Parsons, G.; Ford, M.; Crisp, J.; Bernard, E.; Howman-Giles, R.

    1997-01-01

    Full text: DMSA renal scans are frequently requested for the diagnosis and follow-up of acute pyelonephritis and cortical scarring. This study was designed to:- 1. evaluate oblique reconstruction of DMSA SPECT over standard plane reconstruction and planar imaging; and 2. report on the technical aspects important in obtaining high quality DMSA SPECT, particularly in neonates. Over seven months, 210/231 (91 %) of DMSA scans were performed with SPECT on children from age nine days to 16 years, the median age being 2.5 years. 65 patients (31 %) were under one year and 39 (18%) were under six months. Planar and SPECT imaging with standard plane reconstruction and oblique reorientation was performed on the Siemens triple-headed gamma camera. High quality SPECT images were obtained on the smallest babies using a paediatric palette, and were of comparable quality to those of older children. At the time of reporting, the nuclear medicine physician assessed the diagnostic value of the three types of date presented: (1) planar images; (2) standard plane SPECT reconstruction; and (3) oblique SPECT reconstruction. Cortical defects were identified separately for upper, middle and lower poles. Three physicians concluded that high quality SPECT is superior to planar images when assessing the renal cortex. In addition, oblique reorientation is superior to standard reconstruction, particularly at the upper and lower poles. SPECT is now performed routinely on patients of all ages, and the oblique sagittal and coronal reorientation is now used in place of the standard reconstruction

  3. Interactions of collimation, sampling and filtering on spect spatial resolution

    International Nuclear Information System (INIS)

    Tsui, B.M.W.; Jaszczak, R.J.

    1984-01-01

    The major factors which affect the spatial resolution of single-photon emission computer tomography (SPECT) include collimation, sampling and filtering. A theoretical formulation is presented to describe the relationship between these factors and their effects on the projection data. Numerical calculations were made using commercially available SPECT systems and imaging parameters. The results provide an important guide for proper selection of the collimator-detector design, the imaging and the reconstruction parameters to avoid unnecessary spatial resolution degradation and aliasing artifacts in the reconstructed image. In addition, the understanding will help in the fair evaluation of different SPECT systems under specific imaging conditions

  4. Metabolic imaging using SPECT

    International Nuclear Information System (INIS)

    Taki, Junichi; Matsunari, Ichiro

    2007-01-01

    In normal condition, the heart obtains more than two-thirds of its energy from the oxidative metabolism of long chain fatty acids, although a wide variety of substrates such as glucose, lactate, ketone bodies and amino acids are also utilised. In ischaemic myocardium, on the other hand, oxidative metabolism of free fatty acid is suppressed and anaerobic glucose metabolism plays a major role in residual oxidative metabolism. Therefore, metabolic imaging can be an important technique for the assessment of various cardiac diseases and conditions. In SPECT, several iodinated fatty acid traces have been introduced and studied. Of these, 123 I-labelled 15-(p-iodophenyl)3-R, S-methylpentadecanoic acid (BMIPP) has been the most commonly used tracer in clinical studies, especially in some of the European countries and Japan. In this review article, several fatty acid tracers for SPECT are characterised, and the mechanism of uptake and clinical utility of BMIPP are discussed in detail. (orig.)

  5. The Performance of Ictal Brain SPECT for Localizing Epileptogenic Foci in Temporal Lobe epilepsies

    International Nuclear Information System (INIS)

    Kim, Eun Sil; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Chang, Kee Hyun; Lee, Sang Kun; Chung, Chun Kee

    1995-01-01

    Anterior temporal lobectomy has become a widely used respective surgery in patients with medically intractable temporal lobe epilepsies. Prerequisites of this resection include the accurate localization of the epileptogenic focus and the determination that the proposed resection would not result in unacceptable postoperative memory or language deficits. The purpose of this study was to evaluate the performance of ictal SPECT compared to MRI findings for localization of epileptogenic foci in this group of patients. 11 patients who had been anterior temporal oral lobectomy were evaluated with ictal 99m Tc-HMPAO SPECT and MRI. MRI showed 8/11(73%) concordant lesion to the side of surgery and ictal SPECT also showed 8/11(73%) concordant hyperperfusion. In 3 cases with incorrect or nonlocalizing findings of MRI, ictal SPECT showed concordant hyperperfusion. In 2 cases confirmed by pre-resectional invasive EEG, MRI showed bilateral and contralateral lesion but ictal SPECT showed concordant hyperperfusion. 3 delayed injection of ictal SPECT showed discordant hyperperfusion. Thus, ictal SPECT was a useful method for localizing epileptogenic foci in temporal lobe epilepsies and appeared complementay to MRI.

  6. The characteristics of SPECT images in childhood benign partial epilepsy

    International Nuclear Information System (INIS)

    Jia Shaowei; Liao Jianxiang; Liu Xiaoyan; Zheng Xiyuan; Qin Jiong; Pan Zhongyun; Zuo Qihua

    1998-01-01

    Purpose: To investigate childhood benign partial epilepsy (BPE) with SPECT. Methods: Double SPECT imaging was performed on 21 cases of BPE at the stage of wake (interval spike discharge) and sleep (spike discharge), under EEG monitoring. The transverse images were reconstructed after digital image subtraction. The quantitative analysis was conducted with brain flow change rate (BFCR) % mathematical model. Results: EEG monitoring demonstrated approximately normal background of 21 cases of BPE during the stage of wake, and spike discharge frequency markedly increased during the stage of sleep, 117 foci were showed by SPeCT in cases of BPE, and the average was 5.6 +- 1.6 foci/case. The characteristics of SPECT transverse images were 1) multiple foci of mirror, 2) mostly seen in Rolandic region, 3) circular symbol, 4) the radioactivity in foci decreased during the stage of wake (interval spike discharge) and increased during the stage of sleep (spike discharge). The concordance of SPECT and EEG was 93.1% (109/117 foci). The BFCR% of all epileptogenic foci exceeded normal limit (99% confidence interval). There was no correlation between the spike discharge frequency and BFCR% (r = 0.45, P>0.05). Conclusions: Regional cerebral blood flow and function were abnormal during the epileptogenic foci were discharging abnormally in BPE

  7. High-resolution brain SPECT imaging by combination of parallel and tilted detector heads.

    Science.gov (United States)

    Suzuki, Atsuro; Takeuchi, Wataru; Ishitsu, Takafumi; Morimoto, Yuichi; Kobashi, Keiji; Ueno, Yuichiro

    2015-10-01

    To improve the spatial resolution of brain single-photon emission computed tomography (SPECT), we propose a new brain SPECT system in which the detector heads are tilted towards the rotation axis so that they are closer to the brain. In addition, parallel detector heads are used to obtain the complete projection data set. We evaluated this parallel and tilted detector head system (PT-SPECT) in simulations. In the simulation study, the tilt angle of the detector heads relative to the axis was 45°. The distance from the collimator surface of the parallel detector heads to the axis was 130 mm. The distance from the collimator surface of the tilted detector heads to the origin on the axis was 110 mm. A CdTe semiconductor panel with a 1.4 mm detector pitch and a parallel-hole collimator were employed in both types of detector head. A line source phantom, cold-rod brain-shaped phantom, and cerebral blood flow phantom were evaluated. The projection data were generated by forward-projection of the phantom images using physics models, and Poisson noise at clinical levels was applied to the projection data. The ordered-subsets expectation maximization algorithm with physics models was used. We also evaluated conventional SPECT using four parallel detector heads for the sake of comparison. The evaluation of the line source phantom showed that the transaxial FWHM in the central slice for conventional SPECT ranged from 6.1 to 8.5 mm, while that for PT-SPECT ranged from 5.3 to 6.9 mm. The cold-rod brain-shaped phantom image showed that conventional SPECT could visualize up to 8-mm-diameter rods. By contrast, PT-SPECT could visualize up to 6-mm-diameter rods in upper slices of a cerebrum. The cerebral blood flow phantom image showed that the PT-SPECT system provided higher resolution at the thalamus and caudate nucleus as well as at the longitudinal fissure of the cerebrum compared with conventional SPECT. PT-SPECT provides improved image resolution at not only upper but also at

  8. SPECT imaging of cardiac reporter gene expression in living rabbits

    International Nuclear Information System (INIS)

    Liu Ying; Lan Xiaoli; Zhang Liang; Wu Tao; Jiang Rifeng; Zhang Yongxue

    2009-01-01

    This work is to demonstrate feasibility of imaging the expression of herpes simplex virus 1-thymidine kinase (HSVI-tk) reporter gene in rabbits myocardium by using the reporter probe 131 I-2'-fluoro-2'-deoxy-l-β-D-arabinofuranosyl-5-iodouracil ( 131 I-FIAU) and SPECT. Rabbits of the study group received intramyocardial injection of Ad5-tk and control group received aseptic saline injection. Two sets of experiments were performed on the study group. Rabbits of the 1st set were injected with 131 I-FIAU 600 μCi at Day 2 after intramyocardial transfection of Ad5-tk in 1xl0 9 , 5x10 8 , 1x10 8 , 5x10 7 and 1x10 7 pfu, and heart SPECT imaging was done at different hours. Rabbits of the 2nd were transferred various titers of Ad5-tk (1x10 9 , 5x10 8 , 1x10 8 , 5x10 7 , 1x10 7 pfu) to determine the threshold and optimal viral titer needed for detection of gene expression. Two days later, 131 I-FIAU was injected and heart SPECT imaging was performed at 6, 24 and 48 h, before killing them for gamma counting of the hearts. Reverse transcription-polymerase chain reaction (RT-PCR) was used to verify the transferred HSVI-tk gene expression. Semi-quantitative analysis derived of region of interest (ROI) of SPECT images and RT-PCR images was performed and the relationship of SPECT images with ex vivo gamma counting and mRNA level were evaluated. SPECT images conformed 131 I-FIAU accumulation in rabbits injected with Ad5-tk in the anterolateral wall. The optimal images quality was obtained at 24-48 h for different viral titers. The highest radioactivity in the focal myocardium was seen at 6 h, and then declined with time. The threshold was 5x10 7 pfu of virus titer. The result could be set better in 1-5x10 8 pfu by SPECT analysis and gamma counting. ROI-derived semi-quantitative study on SPECT images correlated well with ex vivo gamma counting and mRNA levels from RT-PCR analysis. The HSVI-tk/ 131 I-FIAU reporter gene/reporter probe system is feasible for cardiac SPECT reporter

  9. Extraosseous accumulation of bone scanning agents in malignant brain tumors. Comparison to semi-quantitative evaluation with 99mTc SPECT/201Tl SPECT and histological findings

    International Nuclear Information System (INIS)

    Suzuki, Aya

    2003-01-01

    Although 201 Tl chloride (Tl) SPECT has been used in the differential diagnosis between recurrence of malignant brain tumor and necrosis after treatment, it is not generally recognized as a definite modality to distinguish them. We conducted a preliminary study using Tl SPECT and 99m Tc-MDP or 99m Tc-HMDP (Tc) SPECT because it has been said that extraosseous accumulation was caused by calcium deposits in necrotic tissues. In our study, for the purposes of clarifying the mechanism of extraosseous uptake and the correlation between extraosseous accumulation of bone-scanning agent and tumor viability in malignant brain tumors, we compared whether Tc uptake was correlated with the histopathological findings and further performed semi-quantitative evaluation between Tc SPECT and Tl SPECT. The correlation coefficients between the ratio of tumor to normal skull count obtained from Tc SPECT (Tc-T/N) and those of tumor to normal brain count (T/N) and to normal scalp count (T/S) both obtained from Tl SPECT were calculated. Using contrast enhanced CT (CE-CT) or contrast enhanced MRI (CE-MRI), 8 of 10 cases showed intensely ring-enhanced tumor with necrotic lesion. Histopathologically, 7 of 8 cases whose tumor had been resected before treatment had necrosis with increased vascularity or bleeding. Of the remaining 2 cases one case, malignant lymphoma had only hypervascularity by biopsy, while the other one was excluded for resection after treatment. Three of these 8 cases whose CE-CT or CE-MRI showed necrotic lesions exhibited Tc and Tl accumulations in the area corresponding to necrosis. In contrast, 2 showed no Tc nor Tl uptake. Tc-T/N had no significant correlation with any of early-, delayed-T/N or T/S. In conclusion, there was no significant correlation between Tc and Tl uptakes by malignant brain tumors in semi-quantitative evaluation. (author)

  10. Dobutamine stress tetrofosmin SPECT. Evaluation of short rest-stress protocol and head to head comparison with MIBI in detection of coronary artery disease

    International Nuclear Information System (INIS)

    Turgut, B.; Unlu, M.; Cengel, A.

    2005-01-01

    The purpose of the present study was to evaluate the feasibility and diagnostic accuracy of same day short rest-dobutamine stress Tetrofosmin (TF) SPECT imaging protocol and to compare TF SPECT results with methoxyisobutyl isonitrile (MIBI) SPECT in the same subjects who were unable to perform treadmill exercise or were unsuitable for pharmacological vasodilator stress. The study group consisted of 19 patients (2 female and 17 male, with a mean age of 53.8±7.9 yrs) in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography (CA). MIBI SPECT imaging was performed first. TF SPECT images were obtained one week after MIBI imaging. Immediately after the rest SPECT imaging in both of the MIBI and TF studies, patients underwent dobutamine stress tests. Rest-stress radiotracer doses and dobutamine doses were the same for both TF and MIBI studies. While 60 min waiting periods were applied for MIBI study, only 30 min waiting periods were applied for TF study after the rest and stress injections. Images were evaluated by visual and quantitative analysis. Dobutamine stress parameters were similar for both studies. Although in TF study, the time between radiopharmaceutical injection and imaging was shorter than in MIBI study, there was no significant difference between heart-to-liver (H/Li) and heart-to-lung (H/Lu) ratios. According to CA results, diagnostic accuracy was similar for TF and MIBI. While sensitivity, specificity and accuracy for TF study were calculated as 82%, 84% and 82%, respectively, the corresponding values for MIBI were 82%, 88% and 84%, respectively. This clinical study has shown comparable diagnostic performance for the detection of CAD between MIBI and TF. Good correlation was found between segmental analysis for both studies. MIBI and TF showed similar perfusion defects and good segmental correlation during dobutamine stress with the same quality images. Both radiopharmaceuticals may be acceptable with this imaging protocol

  11. Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions

    International Nuclear Information System (INIS)

    Das, S.K.; Miften, M.M.; Zhou, S.; Bell, M.; Munley, M.T.; Whiddon, C.S.; Craciunescu, O.; Baydush, A.H.; Wong, T.; Rosenman, J.G.; Dewhirst, M.W.; Marks, L.B.

    2004-01-01

    The information provided by functional images may be used to guide radiotherapy planning by identifying regions that require higher radiation dose. In this work we investigate the dosimetric feasibility of delivering dose to lung tumors in proportion to the fluorine-18-fluorodeoxyglucose activity distribution from positron emission tomography (FDG-PET). The rationale for delivering dose in proportion to the tumor FDG-PET activity distribution is based on studies showing that FDG uptake is correlated to tumor cell proliferation rate, which is shown to imply that this dose delivery strategy is theoretically capable of providing the same duration of local control at all voxels in tumor. Target dose delivery was constrained by single photon emission computed tomography (SPECT) maps of normal lung perfusion, which restricted irradiation of highly perfused lung and imposed dose-function constraints. Dose-volume constraints were imposed on all other critical structures. All dose-volume/function constraints were considered to be soft, i.e., critical structure doses corresponding to volume/function constraint levels were minimized while satisfying the target prescription, thus permitting critical structure doses to minimally exceed dose constraint levels. An intensity modulation optimization methodology was developed to deliver this radiation, and applied to two lung cancer patients. Dosimetric feasibility was assessed by comparing spatially normalized dose-volume histograms from the nonuniform dose prescription (FDG-PET proportional) to those from a uniform dose prescription with equivalent tumor integral dose. In both patients, the optimization was capable of delivering the nonuniform target prescription with the same ease as the uniform target prescription, despite SPECT restrictions that effectively diverted dose from high to low perfused normal lung. In one patient, both prescriptions incurred similar critical structure dosages, below dose-volume/function limits

  12. Diagnostic value of 123I-betamethyl-p-iodophenyl-pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) in patients with chest pain. Comparison with rest-stress 99mTc-tetrofosmin SPECT and coronary angiography

    International Nuclear Information System (INIS)

    Kawai, Yuko; Nozaki, Yoichi; Ohkusa, Takanori; Sakurai, Masayuki; Morita, Koichi; Tamaki, Nagara

    2004-01-01

    Basic and clinical studies have indicated that 15-(p-[ 123 I] iodophenyl)-3-(R, S) methylpentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) can identify ischemic myocardium without evidence of myocardial infarction by the regional decline of tracer uptake. The present study compared BMIPP SPECT with rest-stress myocardial perfusion imaging (MPI) findings and coronary angiography (CAG) in 150 patients with acute chest pain. Patients with acute chest pain who underwent all of the following tests were selected: MPI at rest-stress, BMIPP SPECT at rest and CAG. Organic coronary artery stenosis (≥75%) was observed in 46 patients, 27 patients had total or subtotal coronary occlusion by spasm in the spasm provocation test on CAG and the remaining 77 patients had no significant coronary artery stenosis or spasm. The sensitivity of BMIPP at rest to detect organic stenosis was significantly higher (54%) than that of rest-MPI (33%, p<0.005), but lower than that of stress-MPI (76%, p=0.05). The sensitivity of BMIPP at rest to detect spasm was significantly higher (63%) than that of both rest-MPI (15%; p<0.001) and stress-MPI (19%; p<0.001). Overall, the sensitivity of BMIPP at rest to detect both organic stenosis and spasm was significantly higher (58%) than that of rest-MPI (26%; p<0.001), despite having no significance with that of stress-MPI (55%). The specificity was not significantly different among the three imaging techniques. Resting BMIPP SPECT is an alternative method to stress MPI for identifying patients with not only organic stenosis but also spasm without the need for a stress examination. (author)

  13. rCBF SPECT in Parkinson's disease patients with mental dysfunction

    International Nuclear Information System (INIS)

    Bissessur, S.; Tissingh, G.; Wolters, E.C.; Scheltens, P.

    1997-01-01

    Functional imaging of the brain using SPECT provides information correlative to the alterations of regional blood flow. In this paper we review the literature pertaining to SPECT in Parkinson's disease with and without dementia and depression. Parkinson's disease itself is not associated with a consistent pattern of cerebral blood flow alterations in the basal ganglia, but reduced parietal blood flow is more often reported. The heterogeneity of blood flow changes possibly reflects the multifactorial pathophysiology of the disease. In demented Parkinson's disease patients frontal hypoperfusion is often found or bilateral temporoparietal deficits, probably indicative of concomitant Alzheimer's disease. The SPECT studies undertaken in depressed patients with and without Parkinson's disease show highly conflicting and inconsistent results, probably due to methodological and diagnostic flaws (especially the inclusion of demented Parkinson patients). Several lines of reasoning point to a prefrontal dysfunction and future SPECT studies are planned to study this region in non-demented Parkinson's disease patients with and without major depression. (author)

  14. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  15. The need of appropriate brain SPECT templates for SPM comparisons

    International Nuclear Information System (INIS)

    Morbelli, S.; Altrinetti, V.; Piccardo, A.; Rodriguez, G.; Brugnolo, A.; Nobili, F.; Mignone, A.; Pupi, A.; Koulibaly, P.M.

    2008-01-01

    Statistical parametric mapping (SPM) is used worldwide to compare brain perfusion single photon emission computed tomography (SPECT) data. The default template within the SPM package used for SPECT image normalization includes images of a group of healthy subjects studied with 99m TcHMPAO. Since [ 99m Tc] HMPAO and [ 99m Tc] ECD have shown to distribute differently in SPECT studies, we formulated the hypothesis that comparing set of [ 99m Tc]ECD data normalized by means of a [ 99m Tc]HMPAO template may lead to incorrect results. A customized [ 99m Tc]ECD template was built with SPECT and magnetic resonance imaging (MRI) images of 22 neurologically healthy women. Then, two sets of subjects, i.e. a group of patients with very early Alzheimer's disease (eAD) and a matched control group, studied by means of [ 99m Tc]ECD SPECT, were chosen for comparisons. The same statistical approach (t-test between eAD patients and controls and correlation analysis between brain SPECT and a cognitive score) was applied twice, i.e. after normalization with either the default [ 99m Tc]HMPAO template or the customized [ 99m Tc]ECD template. In the comparison between eAD and controls, a cluster of difference in the posterior-cingulate gyrus of both hemispheres was only highlighted when using the customized [ 99m Tc]ECD template, but was missed when using the default [ 99m Tc]HMPAO template. In the correlation between brain perfusion and a cognitive score, the significant cluster was more significant and far more extended, also including the right superior temporal gyrus, using the customized [ 99m Tc]ECD template than using the default [ 99m Tc]HMPAO template. These data suggest the need of customized, radiopharmaceutical-matched SPECT templates to be used within the SPM package. The present customized [ 99m Tc]ECD template is now freely available on the web. (authors)

  16. Comparison of SPECT and CT in detecting skull base invasion in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zhang Li; Wang Jinchuan; Pu Nuo; Song Wenzhong; Chen Mingxi

    2002-01-01

    Objective: To investigate the detecting ability of single photon emission computed tomography (SPECT) and CT in skull base invasion in nasopharyngeal carcinoma. Methods: Sixty-three patients with nasopharyngeal carcinoma were examined by whole body and skull base SPECT and CT of nasopharynx and skull base before radiotherapy. The results were double-blind compared and evaluated. Results: The overall positive rates of skull base invasion detected by SPECT and CT were 63.5% and 25.4%. In patients with headache, cranial nerve palsy and both, they were 87.9%, 93.3%, 92.3% and 42.4%, 46.7%, 46.2%. In patients with T 1 + T 2 and T 3 + T 4 lesions, they were 37.5%, 90.3% and 0.0%, 51.6%. In patients with N 0 + N 1 and N 2 + N 3 lesions, they were 63.9%, 63.0% and 19.4%, 33.3%. The positive rates of SPECT were higher than those of CT (McNemar Test, P < 0.05). The conformation rate between SPECT and CT was 61.9% and the dissimilitude rate was 38.1%. Binary Logistic regression analysis showed that headache and T stages were risk factors of positive SPECT rate (ORheadache = 3.864, ORTstage= 6.422) while Tstage and Nstage were the risk factors for positive CT rate (ORTstage = 48.932, ORNstage = 2.860). Conclusions: The detection sensitivity of SPECT in skull base invasion in nasopharyngeal carcinoma is superior to that of CT. But its specificity is inferior to that of CT. The detecting results in SPECT are better related to symptoms, signs and stage. Combining headache and cranial nerve palsy with T and N stage, the authors may much improve the results of SPECT and CT in the detection of skull base invasion in nasopharyngeal carcinoma. Further study is warranted

  17. Clinical significance of I-123 IMP brain SPECT in children with brain diseases

    International Nuclear Information System (INIS)

    Takishima, Teruo; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Hasegawa, Noriko

    1990-01-01

    Single photon emission computed tomography (SPECT) of the brain using N-isopropyl p-I-123-iodoamphetamine (I-123 IMP) was performed in 43 children with suspected brain diseases. Forty-three children (25 males and 18 females), with an age range of 24 days-15 years (mean: 6.6 years), were included in the study. Six patients were subsequently diagnosed as normal. Early SPECT of the brain was performed 30 minutes after intravenous administration of 74-111 MBq (2-3 mCi) I-123 IMP using a rotating gamma camera equipped with a 30-degree slant hole and medium energy collimator. Transverse images were reconstructed by Shepp-Logan filtered back projection method with attenuation correction after spatial filtering using an 8th order Butterworth-Wiener filter. Findings of I-123 IMP SPECT were compared with those of X-ray computed tomography (CT) and electroencephalography (EEG). The results showed that in I-123 IMP SPECT, abnormality was found in 30 out of 37 children with brain diseases. The incidence of abnormal findings in the 37 patients was 81% in I-123 IMP SPECT, 61% in X-ray CT, and 78% in EEG; in both cryptogenic and secondary epilepsy, the incidence of abnormality was higher in I-123 IMP SPECT than in X-ray CT. (70% and 94% vs 50% and 81% respectively), and epileptic foci detected by EEG did not correspond with defects found using I-123 IMP SPECT in 27% of the patients; and in asphyxiated infants, a high incidence of abnormality was observed on both I-123 IMP SPECT (86%) and X-ray CT (86%). In conclusion, I-123 IMP SPECT is a clinically useful examination in children with brain disease. (author)

  18. Preliminary application of brain perfusion SPECT imaging in schizophrenia

    International Nuclear Information System (INIS)

    Wu Zhixing; Guo Chanliu; Li Xingbao; Liang Rongxiang; Zhao Jun; Yan Tingxiu

    1996-01-01

    The clinical value of 99m Tc-ECD brain perfusion SPECT imaging was evaluated in patients with schizophrenia. 32 patients with schizophrenia and 21 normal controls were analyzed with 99m Tc-ECD SPECT. 93.8% (30/32) of the patients showed decreased regional cerebral blood flow (rCBF). There was normal rCBF in controls. In the patient group rCBF decreased significantly in bilateral frontal lobes, left temporal lobe and right basal ganglion. The rCBF of left temporal lobe was significantly lower than that of right temporal lobe. The decreasing rCBF was not significantly related to previous treatment and duration of illness. 99m Tc-ECD SPECT is useful for the study and diagnosis of patients with schizophrenia

  19. Cortical region of interest definition on SPECT brain images using X-ray CT registration

    Energy Technology Data Exchange (ETDEWEB)

    Tzourio, N.; Sutton, D. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot); Joliot, M. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot INSERM, Orsay (France)); Mazoyer, B.M. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot Antenne d' Information Medicale, C.H.U. Bichat, Paris (France)); Charlot, V. (Hopital Louis Mourier, Colombes (France). Service de Psychiatrie); Salamon, G. (CHU La Timone, Marseille (France). Service de Neuroradiologie)

    1992-11-01

    We present a method for brain single photon emission computed tomography (SPECT) analysis based on individual registration of anatomical (CT) and functional ([sup 133]Xe regional cerebral blood flow) images and on the definition of three-dimensional functional regions of interest. Registration of CT and SPECT is performed through adjustment of CT-defined cortex limits to the SPECT image. Regions are defined by sectioning a cortical ribbon on the CT images, copied over the SPECT images and pooled through slices to give 3D cortical regions of interest. The proposed method shows good intra- and interobserver reproducibility (regional intraclass correlation coefficient [approx equal]0.98), and good accuracy in terms of repositioning ([approx equal]3.5 mm) as compared to the SPECT image resolution (14 mm). The method should be particularly useful for analysing SPECT studies when variations in brain anatomy (normal or abnormal) must be accounted for. (orig.).

  20. Thoracic and abdominal SPECT imaging in systemic amyloidosis in identifying multiorgan involvement

    International Nuclear Information System (INIS)

    Wellman, H.N.; Benson, M.D.; Park, H.M.; Siddiqui, A.R.; Krepshaw, J.D.

    1988-01-01

    Thirty-three patients with systemic amyloidosis have been studied. Thoracic single photon emission computed tomography (SPECT) for myocardial involvement and skeletal imaging were performed with Tc-99m PYP, and abdominal SPECT with TcS colloid. Myocardial wall involvement was easily discernible with SPECT in 17 cases, and in many with normal ultrasonography. PYP uptake was also observed in liver (five patients), kidneys (four patients), and soft tissues (two patients). Most patients had widespread degenerative joint disease. With TcS colloid, intrinsic liver abnormalities were found in four patients, hepatomegaly in seven, and splenic infiltration in two. Nuclear SPECT and planar imaging characterize the distribution of systemic amyloidosis in organs, distribution not readily identified with other diagnostic modalities

  1. Brain perfusion SPECT in dementia syndromes

    International Nuclear Information System (INIS)

    Libus, P.; Stupalova, J.; Kuzelka, I.; Konrad, J.

    2002-01-01

    Aim: Brain perfusion SPECT is used in differential diagnostics of dementia syndromes. First of all the aim is to distinguish vascular dementia from degenerative dementia and to differentiate dementia from delirium, psychiatric syndromes, depression and secondary dementia, which is important in relation to therapy. The purpose of our study was to detect significance of BP SPECT and include it into the diagnostic process in dementia syndromes. Materials and methods: 51 women and 63 men aged 55 - 88 were evaluated in the study. The patients correspond to the general criteria of dementia diagnosis. They were sent to the examination by neurological, internal and psychiatric departments and out-patient departments. All patients were examined by 99mTc ECD SPECT using a double head camera PRISM 200 VP with LEHR collimator. The scintigraphic data were evaluated by the visual and semiquantitative analysis. Results: It was established that most patients in our group had vascular dementia, while Alzheimer's disease was second. In other groups we found out dementia at strategic infarct location, e.g. in gyrus angularis in the dominant hemisphere, frontal temporal lobe dementia and alcoholic dementia. Twenty-four patients had a normal diagnosis. Fifteen of them had a somatic reason of the delirious state and were re-classified into pseudodementia. Nine patients were not diagnostically included and the examination will repeated in four months time. Conclusion: We have found out a good applicability of brain perfusion SPECT in dementia syndromes diagnosis in our work. The best diagnosticable and most specific were the findings in multi-infarct dementia, Alzheimer's disease and frontal temporal lobe dementia. When vascular dementia is concerned we can even distinguish dementia at strategic infarction location, e.g. in thalamus, basal frontal telencefalon, in gyrus angularis of the dominant hemisphere, etc

  2. 99mTc-HMPAO Brain SPECT in Patients with Post-Traumatic Organic Mental Disorder

    International Nuclear Information System (INIS)

    Lee, Kang Wook; Lee, Dong Jin; Shong, Min Ho; Kang, Min Hee; Ghi, Ick Sung; Shin, Young Tai; Ro, Heung Kyu

    1994-01-01

    It is well known that 99m Tc-HMPAO brain SPECT can reflect the functional lesions better than X-ray computerized tomography(CT) and magnetic resonance imaging(MRI) in the cerebral disorders. In order to evaluate the clinical utilities of 99m Tc-HMPAO brain SPECT in patients with post-traumatic chronic organic mental disorder(OMD). We included 28 patients diagnosed as OMD in department of psychiatry after traumatic head injury. And we compared the results of 99m Tc-HMPAO SPECT with those of MRI, EEG and MINI mental status examination(MMSE). The results were as follows 1) All patients diagnosed as OMD showed diffuse or focal decreased cerebral perfusion on 99m Tc-HMPAO SPECT. 2) Most frequent lesion on brain 99m Tc-HMPAO SPECT was decreased perfusion on both frontal lobe. And most frequent lesion on brain 99m Tc-HMPAO SPECT was decreased perfusion on both frontal lobe. And most frequent lesion on brain 99m Tc-HMPAO SPECT showing normal brain MRI result was also decreased both frontal perfusion. 3) Eight of 28 patients showed focal brain MRI lesions(4 small frontal hygroma, 3 small cerebral infarction and 1 cerebellar encephalomalacia) which were not detected in brain 99m Tc-HMPAO SPECT. 4) The patients showing less than 20 points on MMSE disclosed abnormal results of EEG more frequently than those disclosing more than 20 points. In conclusion, we think that 99m Tc-HMPAO brain SPECT is sensitive method to detect functional lesions of the brains in patients with chronic post-traumatic organic mental disorder.

  3. Neuropharmacological studies with SPECT in neuropsychiatric disorders

    International Nuclear Information System (INIS)

    Heinz, Andreas; Jones, Douglas W.; Raedler, Thomas; Coppola, Richard; Knable, Michael B.; Weinberger, Daniel R.

    2000-01-01

    The last decade saw a rapid development of single photon emission computed tomography (SPECT) from a tool to assess cerebral blood flow to the study of specific neurotransmitter systems. Because of the relatively long half-life of SPECT radioisotopes, it is practical to measure the availability of neuroreceptors and transporters in conditions approaching equilibrium. The cost-efficiency of SPECT allowed studies in relatively large samples of patients with various neuropsychiatric disorders. We have applied this approach in studies of dopaminergic, serotonergic, and muscarinergic neurotransmission in patients with dementia, extrapyramidal disorders, schizophrenia, and alcoholism. No simple associations were observed between a single defect in one neurotransmitter system and a certain neuropsychiatric disease. Instead, complex dysfunction of several neurotransmitter systems in multiple, partially connected brain circuits have been implicated. Treatment effects also have been characterized. Microdialysis and neurotransmitter depletion studies showed that most radioligands and endogenous neurotransmitters compete for binding at receptors and transporters. Future research directions include the assessment of endogenous neurotransmitter concentrations measured by depletion studies and of genetic effects on neuroreceptor and transporter expression

  4. Neuropharmacological studies with SPECT in neuropsychiatric disorders

    Energy Technology Data Exchange (ETDEWEB)

    Heinz, Andreas; Jones, Douglas W.; Raedler, Thomas; Coppola, Richard; Knable, Michael B.; Weinberger, Daniel R. E-mail: weinberd@intra.nimh.nih.gov

    2000-10-01

    The last decade saw a rapid development of single photon emission computed tomography (SPECT) from a tool to assess cerebral blood flow to the study of specific neurotransmitter systems. Because of the relatively long half-life of SPECT radioisotopes, it is practical to measure the availability of neuroreceptors and transporters in conditions approaching equilibrium. The cost-efficiency of SPECT allowed studies in relatively large samples of patients with various neuropsychiatric disorders. We have applied this approach in studies of dopaminergic, serotonergic, and muscarinergic neurotransmission in patients with dementia, extrapyramidal disorders, schizophrenia, and alcoholism. No simple associations were observed between a single defect in one neurotransmitter system and a certain neuropsychiatric disease. Instead, complex dysfunction of several neurotransmitter systems in multiple, partially connected brain circuits have been implicated. Treatment effects also have been characterized. Microdialysis and neurotransmitter depletion studies showed that most radioligands and endogenous neurotransmitters compete for binding at receptors and transporters. Future research directions include the assessment of endogenous neurotransmitter concentrations measured by depletion studies and of genetic effects on neuroreceptor and transporter expression.

  5. Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition

    Science.gov (United States)

    Hamamura, Mark J.; Ha, Seunghoon; Roeck, Werner W.; Tugan Muftuler, L.; Wagenaar, Douglas J.; Meier, Dirk; Patt, Bradley E.; Nalcioglu, Orhan

    2010-03-01

    In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system. Various phantom experiments characterized the interaction between the SPECT and MRI hardware components. The metallic components of the SPECT hardware altered the B0 field and generated a non-uniform reduction in the signal-to-noise ratio (SNR) of the MR images. The presence of a magnetic field generated a position shift and resolution loss in the nuclear projection data. Various techniques were proposed to compensate for these adverse effects. Overall, our results demonstrate that accurate, simultaneous SPECT and MRI data acquisition is feasible, justifying the further development of MRSPECT for either small-animal imaging or whole-body human systems by using appropriate components.

  6. Problems in the optimum display of SPECT images

    International Nuclear Information System (INIS)

    Fielding, S.L.

    1988-01-01

    The instrumentation, computer hardware and software, and the image display system are all very important in the production of diagnostically useful SPECT images. Acquisition and processing parameters are discussed which can affect the quality of SPECT images. Regular quality control of the gamma camera and computer is important to keep the artifacts due to instrumentation to a minimum. The choice of reconstruction method will depend on the statistics in the study. The paper has shown that for high count rate studies, a high pass filter can be used to enhance the reconstructions. For lower count rate studies, pre-filtering is useful and the data can be reconstructed into thicker slices to reduce the effect of image noise. Finally, the optimum display for the images must be chosen, so that the information contained in the SPECT data can be easily perceived by the clinician. (orig.) [de

  7. Application of SPECT/CT imaging in the diagnosis of benign diseases

    International Nuclear Information System (INIS)

    Garcheva, M.; Demirev, A.

    2014-01-01

    The application of recently introduced hybrid nuclear medicine methods gains importance in a variety of clinical fields, mainly because of the unique combination between functional and anatomical data provided by those methods and their capability for a precise localization of pathological processes. Single photon emission computed tomography, combined with computed tomography (SPECT/CT) is one of those methods. Its role in nuclear cardiology is important, because it provides quick attenuation correction and calculates the calcium score. In nuclear endocrinology SPECT/CT participates in thyroid and parathyroid examinations, especially in cases, where there is a need for localization of ectopic parathyroid or thyroid tissue. In nuclear pulmonology, one of the best ways to attribute certain changes seen on the SPECT, to the zone of interest on the CT, is to study the fused images obtained from the SPECT/ CT scanner. In cases of suspected infection and inflammation, fused images are indispensable for accurate localization of the involved tissue (structure) and for discrimination between normal/abnormal uptake. Careful reading of the CT component (even low-dose) is related (in 10% of cases) to clinically important incidental findings: effusions, tumors, metastases or lymph node pathology. SPECT/CT increases the specificity of the examinations and improves significantly the localization of pathological processes. It provides additional information, shortens the diagnostic algorithm and influences the extent of surgical procedures. In many hybrid examinations the preferred CT component is a low-dose one, without considerable radiation exposure. The opportunity to combine nuclear medicine techniques and contrast CT images, aiming at better diagnosis needs further development. SPECT/CT provides important additional information and more accurate diagnostics in patients with benign diseases. (authors) Key words: SPECT/CT. BENIGN DISEASES

  8. Partial volume correction in SPECT reconstruction with OSEM

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, Kjell, E-mail: k.erlandsson@ucl.ac.uk [Institute of Nuclear Medicine, University College London and University College London Hospital, London NW1 2BU (United Kingdom); Thomas, Ben; Dickson, John; Hutton, Brian F. [Institute of Nuclear Medicine, University College London and University College London Hospital, London NW1 2BU (United Kingdom)

    2011-08-21

    SPECT images suffer from poor spatial resolution, which leads to partial volume effects due to cross-talk between different anatomical regions. By utilising high-resolution structural images (CT or MRI) it is possible to compensate for these effects. Traditional partial volume correction (PVC) methods suffer from various limitations, such as correcting a single region only, returning only regional mean values, or assuming a stationary point spread function (PSF). We recently presented a novel method in which PVC was combined with the reconstruction process in order to take into account the distance dependent PSF in SPECT, which was based on filtered backprojection (FBP) reconstruction. We now present a new method based on the iterative OSEM algorithm, which has advantageous noise properties compared to FBP. We have applied this method to a series of 10 brain SPECT studies performed on healthy volunteers using the DATSCAN tracer. T1-weighted MRI images were co-registered to the SPECT data and segmented into 33 anatomical regions. The SPECT data were reconstructed using OSEM, and PVC was applied in the projection domain at each iteration. The correction factors were calculated by forward projection of a piece-wise constant image, generated from the segmented MRI. Images were also reconstructed using FBP and standard OSEM with and without resolution recovery (RR) for comparison. The images were evaluated in terms of striatal contrast and regional variability (CoV). The mean striatal contrast obtained with OSEM, OSEM-RR and OSEM-PVC relative to FBP were 1.04, 1.42 and 1.53, respectively, and the mean striatal CoV values are 1.05, 1.53, 1.07. Both OSEM-RR and OSEM-PVC results in images with significantly higher contrast as compared to FBP or OSEM, but OSEM-PVC avoids the increased regional variability of OSEM-RR due to improved structural definition.

  9. D-SPECT, a semiconductor camera: Technical aspects and clinical applications

    International Nuclear Information System (INIS)

    Merlin, C.; Bertrand, S.; Kelly, A.; Veyre, A.; Mestas, D.; Cachin, F.; Motreff, P.; Levesque, S.; Cachin, F.; Askienazy, S.

    2010-01-01

    Clinical practice in nuclear medicine has largely changed in the last decade, particularly with the arrival of PET/CT and SPECT/CT. New semiconductor cameras could represent the next evolution in our nuclear medicine practice. Due to the resolution and sensitivity improvement, this technology authorizes fast speed acquisitions, high contrast and resolution images performed with low activity injection. The dedicated cardiology D-SPECT camera (Spectrum Dynamics, Israel) is based on semiconductor technology and provides an original system for collimation and images reconstruction. We describe here our clinical experience in using the D-SPECT with a preliminary study comparing D-D.P.E.C.T. and conventional gamma camera. (authors)

  10. The contribution of bone SPECT to the diagnosis of bone metastases in an African population

    International Nuclear Information System (INIS)

    Elmadini, A.E.; Warwick, J.M.; Ellmann, A.

    2004-01-01

    Full text: Introduction: A number of studies have demonstrated the value of performing spinal SPECT in addition to planar scintigraphy for the diagnosis of bone metastases. This has however not been demonstrated in an African population where patients frequently present with more advanced disease. The aim of this study was to investigate the contribution of spinal SPECT to the diagnosis of bone metastases in an African population. Materials and methods: In a retrospective study of 576 patients with known primary tumours who underwent skeletal scintigraphy for the diagnosis of bone metastases, the students of 119 patients who underwent planar imaging and SPECT were reviewed. Blinded to the SPECT study, the planar studies were graded for the probability of metastatic disease using a four-point scale, and the number of spinal lesions was noted. This was repeated with the planar and SPECT studies reviewed together. The interpretation using the planar images alone was compared with that obtained after the addition of SPECT using non-parametric tests. Results: Of the 576 patients, 119 (45 men and 74 women) underwent planar and SPECT imaging. A wide variety of primary malignancies were presented but the majority consisted of breast carcinoma (n=55) and prostate carcinoma (n=29). The addition of SPECT resulted in a significant change in the interpretation of these studies (p<0.05), with a significantly lower proportion of patients having equivocal gradings (p<0.01). However the actual number of patients affected was relatively small (n=35) representing about 6% of the total of 576 patients. The addition of SPECT also resulted in the detection of significantly more spinal lesions (p<0.01 ). Conclusion: The addition of SPECT resulted in a statistically significant change in the interpretation of the studies, demonstrating the value of spinal SPECT in this population. However compared to the total patient population the actual number of patients affected was relatively small

  11. Effects of cross talk on dual energy SPECT imaging between [sup 123]I-BMIPP and [sup 201]Tl

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru (Hyogo College of Medicine, Nishinomiya (Japan))

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.).

  12. Characteristics of images of angiographically proven normal coronary arteries acquired by adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT with CT attenuation correction changed stepwise.

    Science.gov (United States)

    Takahashi, Teruyuki; Tanaka, Haruki; Kozono, Nami; Tanakamaru, Yoshiki; Idei, Naomi; Ohashi, Norihiko; Ohtsubo, Hideki; Okada, Takenori; Yasunobu, Yuji; Kaseda, Shunichi

    2015-04-01

    Although several studies have shown the diagnostic and prognostic value of CT-based attenuation correction (AC) of single photon emission computed tomography (SPECT) images for diagnosing coronary artery disease (CAD), this issue remains a matter of debate. To clarify the characteristics of CT-AC SPECT images that might potentially improve diagnostic performance, we analyzed images acquired using adenosine-stress thallium-201 myocardial perfusion SPECT/CT equipped with IQ[Symbol: see text]SPECT (SPECT/CT-IQ[Symbol: see text]SPECT) from patients with angiographically proven normal coronary arteries after changing the CT attenuation correction (CT-AC) in a stepwise manner. We enrolled 72 patients (Male 36, Female 36) with normal coronary arteries according to findings of invasive coronary angiography or CT-angiography within three months after a SPECT/CT study. Projection images were reconstructed at CT-AC values of (-), 40, 60, 80 and 100 % using a CT number conversion program according to our definition and analyzed using polar maps according to sex. CT attenuation corrected segments were located from the mid- and apical-inferior spread through the mid- and apical-septal regions and finally to the basal-anterior and basal- and mid-lateral regions in males, and from the mid-inferior region through the mid-septal and mid-anterior, and mid-lateral regions in females as the CT-AC values increased. Segments with maximal mean counts shifted from the apical-anterior to mid-anterolateral region under both stress and rest conditions in males, whereas such segments shifted from the apical-septal to the mid-anteroseptal region under both stress and rest conditions in females. We clarified which part of the myocardium and to which degree CT-AC affects it in adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT images by changing the CT-AC value stepwise. We also identified sex-specific shifts of segments with maximal mean counts that changed as

  13. Bone marrow scintigraphy in lung carcinomas using nanosized colloids: when is it useful and how useful is it?

    International Nuclear Information System (INIS)

    Bourgeois, P.; Thimpont, J.; Feremans, W.; Malarme, M.

    1992-01-01

    Bone marrow scintigrams (MS) combined with single photon emission computed tomographic investigation of the liver (liver SPECT) were obtained using 99 Tc m -labelled human serum albumin nanosized colloids in 52 patients with histologically proven lung carcinomas (adenocarcinomas = 17, squamous cell = 16, small cell = 14, large cell 5,31 generalized cases at the time of the first MS investigation among whom 13 patients had proven skeletal metastases). They were compared with conventional bone scintigrams (BS) as well as clinical, biological, radiological and follow-up data obtained for the same patients. In the present series, MS appeared as sensitive as BS in diagnosing skeletal metastases (77%) if all abnormal MS and BS presentations are considered as diagnostic, but more sensitive (77% versus 54%) if more restrictive analytical criteria are applied. The two investigations yielded the same specificities whatever the analytical criteria applied. The most striking differences between BS and MS were observed in the case of small-cell lung carcinomas (14 cases), with more lesions detected by MS than by BS. Liver SPECT also made it possible to diagnose seven and to suspect one out of the ten hepatic metastases. (author)

  14. Lung density

    DEFF Research Database (Denmark)

    Garnett, E S; Webber, C E; Coates, G

    1977-01-01

    The density of a defined volume of the human lung can be measured in vivo by a new noninvasive technique. A beam of gamma-rays is directed at the lung and, by measuring the scattered gamma-rays, lung density is calculated. The density in the lower lobe of the right lung in normal man during quiet...... breathing in the sitting position ranged from 0.25 to 0.37 g.cm-3. Subnormal values were found in patients with emphsema. In patients with pulmonary congestion and edema, lung density values ranged from 0.33 to 0.93 g.cm-3. The lung density measurement correlated well with the findings in chest radiographs...... but the lung density values were more sensitive indices. This was particularly evident in serial observations of individual patients....

  15. MRI and SPECT findings in amyotrophic lateral sclerosis

    International Nuclear Information System (INIS)

    Ukada, F.; Sawada, H.; Seriu, N.; Shindou, K.; Nishitani, N.; Kameyama, M.

    1992-01-01

    MRI was performed in 21 patients and single photon emission computed tomography (SPECT) with N-isopropyl-p- 123 I iodoamphetamine in 16 patients, to visualize upper motor neurone lesions in amyotrophic lateral sclerosis. T2-weighted MRI revealed high signal along the course of the pyramidal tract in the internal capsule and cerebral peduncle in 4 of 21 patients. SPECT images were normal in 4 patients, but uptake was reduced in the cerebral cortex that includes the motor area in 11. (orig.)

  16. Comparison of the prognostic value of SPECT after nitrate administration and metabolic imaging by PET in patients with ischaemic left ventricular dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sorrentino, Anna R.; Acampa, Wanda; Mainolfi, Ciro; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructures and Bioimages of the National Council of Research, Naples (Italy); Petretta, Mario [University Federico II, Department of Internal Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2007-04-15

    We compared the prognostic value of {sup 99m}Tc-tetrofosmin single-photon emission computed tomography (SPECT) after nitrate administration and positron emission tomography (PET) with {sup 18}F-fluorodeoxyglucose (FDG) in patients with ischaemic left ventricular (LV) dysfunction. Eighty-nine patients with previous myocardial infarction and LV dysfunction (LV ejection fraction 33 {+-} 10%) underwent {sup 99m}Tc-tetrofosmin SPECT under control conditions (baseline) and after sublingual administration of 10 mg of isosorbide dinitrate (nitrate). Within 1 week, all patients underwent PET imaging with {sup 18}F-FDG. Four patients were excluded because of inadequate FDG uptake caused by severe diabetes. Follow-up data were obtained by phone contact with patients and by review of hospital or physicians' records. Cardiac death, myocardial infarction and late revascularisation for unstable angina were considered as events. Follow-up data were not available in three patients. Follow-up was 96% complete at a mean period of 29 {+-} 19 months. At baseline SPECT, 59 (72%) patients had evidence of viable myocardium, while 23 did not. Of these latter patients, 12 (52%) demonstrated viable myocardium after nitrate and 13 (56%) had preserved metabolic activity. Cardiac events (cardiac death, myocardial infarction and late revascularisation for unstable angina) occurred in 24 (29%) patients. Event-free survival was similar in patients with and patients without viable myocardium at baseline SPECT (p = 0.8). In contrast, event-free survival was lower in patients with viable myocardium at nitrate SPECT and PET compared to those without viable myocardium (both p<0.05). In patients with ischaemic LV dysfunction, the prognostic value of SPECT imaging after nitrate is comparable to that of PET metabolic imaging. (orig.)

  17. Investigating the role of SPECT/CT in dynamic sentinel lymph node biopsy for penile cancers

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Ziauddin Zia; Bomanji, Jamshed [University College Hospitals London, Department of Nuclear Medicine, London (United Kingdom); UCLH NHS Foundation Trust, Institute of Nuclear Medicine, 5th Floor, London (United Kingdom); Omorphos, Savvas; Malone, Peter; Nigam, Raj; Muneer, Asif [University College Hospitals London, Department of Urology, London (United Kingdom); Michopoulou, Sofia; Gacinovic, Svetislav [University College Hospitals London, Department of Nuclear Medicine, London (United Kingdom)

    2017-07-15

    Currently, most centres use 2-D planar lymphoscintigraphy when performing dynamic sentinel lymph node biopsy in penile cancer patients with clinically impalpable inguinal nodes. This study aimed to investigate the role of SPECT/CT following 2-D planar lymphoscintigraphy (dynamic and static) in the detection and localization of sentinel lymph nodes in the groin. A qualitative (visual) review was performed on planar followed by SPECT/CT lymphoscintigraphy in 115 consecutive patients (age 28-86 years) who underwent injection of {sup 99m}Tc-nanocolloid followed by immediate acquisition of dynamic (20 min) and early static scans (5 min) initially and further delayed static (5 min) images at 120 min followed by SPECT/CT imaging. The lymph nodes detected in each groin on planar lymphoscintigraphy and SPECT/CT were compared. A total of 440 and 467 nodes were identified on planar scintigraphy and SPECT/CT, respectively. Overall, SPECT/CT confirmed the findings of planar imaging in 28/115 cases (24%). In the remaining 87 cases (76%), gross discrepancies were observed between planar and SPECT/CT images. SPECT/CT identified 17 instances of skin contamination (16 patients, 13%) and 36 instances of in-transit lymphatic tract activity (24 patients, 20%) that had been interpreted as tracer-avid lymph nodes on planar imaging. In addition, SPECT/CT identified 53 tracer-avid nodes in 48 patients (42%) that were not visualized on planar imaging and led to reclassification of the drainage basins (pelvic/inguinal) of 27 tracer-avid nodes. The addition of SPECT/CT improved the rate of detection of true tracer-avid lymph nodes and delineated their precise (3-D) anatomic localization in drainage basins. (orig.)

  18. Impact of additional SPECT in bone scanning in tumor patients with suspected metastatic bone disease

    International Nuclear Information System (INIS)

    Apostolova, I.; Goelcuek, E.; Buchert, R.; Brenner, W.; Bohuslavizki, K.H.

    2009-01-01

    The aim of this study was to investigate the additional value of single-photon emission computed tomography (SPECT) for patient staging compared to planar bone scanning in an unselected cohort of cancer patients. The study included 271 consecutive tumor patients in whom planar imaging and two-bed position SPECT of the spine and the pelvis had been performed. Retrospective image interpretation was performed independently for planar and SPECT scans. Findings were categorized as 'benign', 'equivocal', or malignant' on a lesion base, and as 'no metastatic disease', 'equivocal', or metastatic disease' on a patient base. Four hundred and forty seven lesions were detected by SPECT. Missing of lesions in planar images was rare (4.3% of all SPECT lesions). Planar findings differed from SPECT findings in 149 lesions (33.3%). Most of these 'inconsistent' lesions were rated as equivocal in the planar images but benign (14.5% of all lesions) or malignant (11.0%) by SPECT. On a patient base, 81.6% of patients with planar equivocal staging were classified as either benign (55.3%) or malignant (26.3%) by SPECT. Patients definitively staged as 'no metastatic disease' or 'metastatic disease' in planar images were staged differently by SPECT in only 3.7% of cases (up-staging in 2.6% and down-staging in 1.1%). Single-photon emission computed tomography changed a definite staging as based on planar images in less than 4% of the patients. In patients with planar equivocal staging, however, SPECT allowed a definite diagnosis in more than 80% of these cases, and, thus, should be performed routinely in patients with equivocal findings. (author)

  19. SPECT in the Kleine-Levin syndrome, a possible diagnostic and prognostic aid?

    Directory of Open Access Journals (Sweden)

    Patrick Emanuel Vigren

    2014-09-01

    Full Text Available INTRODUCTION: Kleine-Levin syndrome (KLS is a rare syndrome of periodic hypersomnia and behavioral and cognitive symptoms based on clinical criteria. In the setting of differential diagnosis of hypersomnia disorders, an objective diagnostic aid is desirable. A promising modality is single photon emission computed tomography (SPECT. As intraepisodal investigations are difficult to perform, an interepisodal investigation would be very helpful. Another aim of the study was to correlate SPECT findings to prognosis. METHODS AND MATERIAL: 24 KLS-patients were categorized as severe or non-severe based on clinical characteristics. The clinical characteristics were analyzed in relation to SPECT-examinations performed between hypersomnia periods (interepisodal or after remission, as a clinical routine investigation.RESULTS: 48% of the KLS-patients have hypoperfusion in the temporal or fronto-temporal regions. In patients that have undergone remission, 56% show that pattern. There were no specific findings related to prognosis.DISCUSSION/CONCLUSION: SPECT might be a diagnostic aid, in a setting of hypersomnia experience. With a sensitivity of 48%, interepisodal SPECT alone cannot be used for diagnosing KLS.

  20. Clinical Significance of Brain SPECT in Zipeprol Abusers

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Dai Ok; Kim, Jae Phil; Kim, Deog Yoon; Yang, Hyung In; Koh, Eun Mi; Kim, Kwang Won; Choi, Young Kil [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1993-03-15

    Drug abuse is widespread in worldwide and has been associated with neurologic complication. Zipeprol is one of drugs which been abused for psychological satisfaction in some adolescents. This agent is non-opioid antitussive agent, which is not legally considered as being capable of creating dependence or abuse liability at therapeutic serum levels. But it has been reported that acute or chronic overdose create neurologic complication such as convulsion as well as dependence. Recently we experienced six zipeprol abusers who admitted due to convulsion and variable neurologic symptoms. The aim of our study was to determine the role of Tc-99m- HMPAO brain SPECT in those patients. EEG and brain CT showed no abnormal finding, but brain SPECT showed focal or multiple perfusion abnormalities in frontal, parietal, occipital cortex, basal ganglia, thalamus and especially at temporal cortex. These results suggest that brain SPECT may be a useful diagnostic tool to evaluate the cerebral dysfunction induced by zipeprol abuse.

  1. SPECT and MRI in the diagnosis of epilepsy

    International Nuclear Information System (INIS)

    Gruenwald, F.; Biersack, H.J.; Bockisch, A.; Elger, C.E.; Durwen, H.F.; Penin, H.

    1989-01-01

    This study presents the results obtained using SPECT and MRI in epilepsy - mainly based on presurgical investigation in therapy-resistant cases of temporal lobe epilepsy. MRI was positive in 61% of 102 examined patients, SPECT was positive in 84%. In 46 patients with temporal lobe epilepsy subjected to partial temporal lobectomy was performed later on there was agreement of the results obtained with regard to the lateralisation in 74%. Although MRI, due to its sensitivity is superior to CT in diagnosis of epilepsy, CT should be performed in any case because some morphological changes - especially small arteriovenous malformations - are only seen in CT. MRI and SPECT should be considered as two complementary methods in epilepsy diagnosis, serving to evaluate morphology and function. A definite statement as to the predictive value of both methods remains to be made depending on a comparison of the results with the postoperative outcome referring to seizure frequency and cognitive function. (orig.) [de

  2. Novel SPECT Technologies and Approaches in Cardiac Imaging

    Directory of Open Access Journals (Sweden)

    Piotr Slomka

    2016-12-01

    Full Text Available Recent novel approaches in myocardial perfusion single photon emission CT (SPECT have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.

  3. Clinical Significance of Brain SPECT in Zipeprol Abusers

    International Nuclear Information System (INIS)

    Cho, Dai Ok; Kim, Jae Phil; Kim, Deog Yoon; Yang, Hyung In; Koh, Eun Mi; Kim, Kwang Won; Choi, Young Kil

    1993-01-01

    Drug abuse is widespread in worldwide and has been associated with neurologic complication. Zipeprol is one of drugs which been abused for psychological satisfaction in some adolescents. This agent is non-opioid antitussive agent, which is not legally considered as being capable of creating dependence or abuse liability at therapeutic serum levels. But it has been reported that acute or chronic overdose create neurologic complication such as convulsion as well as dependence. Recently we experienced six zipeprol abusers who admitted due to convulsion and variable neurologic symptoms. The aim of our study was to determine the role of Tc-99m- HMPAO brain SPECT in those patients. EEG and brain CT showed no abnormal finding, but brain SPECT showed focal or multiple perfusion abnormalities in frontal, parietal, occipital cortex, basal ganglia, thalamus and especially at temporal cortex. These results suggest that brain SPECT may be a useful diagnostic tool to evaluate the cerebral dysfunction induced by zipeprol abuse.

  4. Familial idiopathic pulmonary fibrosis. Evidence of lung inflammation in unaffected family members

    International Nuclear Information System (INIS)

    Bitterman, P.B.; Rennard, S.I.; Keogh, B.A.; Wewers, M.D.; Adelberg, S.; Crystal, R.G.

    1986-01-01

    We evaluated 17 clinically unaffected members of three families with an autosomal dominant form of idiopathic pulmonary fibrosis for evidence of alveolar inflammation. Each person in the study was examined by gallium-67 scanning for a general estimate of pulmonary inflammation, and by bronchoalveolar lavage for characterization of the types of recovered cells and their state of activation. Eight of the 17 subjects had evidence of alveolar inflammation on the lavage studies. Supporting data included increased numbers of neutrophils and activated macrophages that released one or more neutrophil chemoattractants, and growth factors for lung fibroblasts--findings similar to those observed in patients with overt idiopathic pulmonary fibrosis. Four of these eight also had a positive gallium scan; in all the other clinically unaffected subjects the scan was normal. During a follow-up of two to four years in seven of the eight subjects who had evidence of inflammation, no clinical evidence of pulmonary fibrosis has appeared. These results indicate that alveolar inflammation occurs in approximately half the clinically unaffected family members at risk of inheriting autosomal dominant idiopathic pulmonary fibrosis. Whether these persons with evidence of pulmonary inflammation but no fibrosis will proceed to have clinically evident pulmonary fibrosis is not yet known

  5. Potential value of serial cerebral SPECT scanning in the evaluation of psychiatric illness

    International Nuclear Information System (INIS)

    Notardonato, H.; Gonzalez-Avilez, A.; Van Heertum, R.L.; O'Connell, R.A.; Yudd, A.P.

    1989-01-01

    Cerebral SPECT imaging has the potential to make an important contribution to clinical psychiatry. Cerebral SPECT scanning, stimulated by the work with PET, is readily available and much less expensive than PET. This paper reports a case demonstrating the potential value of cerebral SPECT scanning with I-123 IMP, specifically in the serial evaluation of a schizophrenic patient with auditory hallucinations. The initial scan revealed focal areas of increased uptake in the caudate nuclei of the basal ganglia, and in the right temporal lobe. After pharmacological treatment with clinical improvement, the follow-up SPECT scan demonstrated significant improvement in the distribution of the radiopharmaceutical

  6. Small hepatocellular carcinomas in chronic liver disease: Detection with SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kudo, M.; Hirasa, M.; Takakuwa, H.; Ibuki, Y.; Fujimi, K.; Miyamura, M.; Tomita, S.; Komori, H.; Todo, A.; Kitaura, Y.

    1986-06-01

    Single-photon emission computed tomography (SPECT) performed using a rotating gamma camera was compared with ..cap alpha../sub 1/-fetoprotein (AFP) assay, conventional liver scintigraphy, ultrasound (US) imaging, computed tomography (CT), and selective celiac angiography in 40 patients with a total of 50 small hepatocellular carcinomas (HCCs;<5 cm). The detection rates of US and CT were determined on an initial screening study and on a second, more precisely focused study. The detection rate of small HCCs by the various modalities was as follows: AFP, 13%; liver scintigraphy, 36%; SPECT, 72%; initial screening US, 80%; second, more precise US studies, 94%; initial screening CT, 64%; second, more precise CT study, 82%; angiography, 88%. Although SPECT was inferior to the initial screening US examination in detecting HCCs less than 2 cm in size, its sensitivity was identical to that of the initial screening US study for detecting HCCs of 2-5 cm. The combination of SPECT and US was an excellent method for the early detection of HCCs, yielding a detection rate of 94%.

  7. Clinical value of SPECT/CT imaging in the diagnosis of bone metastasis

    International Nuclear Information System (INIS)

    Wang Xinhua; Zhao Yanping; Lu Haijian; Dong Zhanfei

    2010-01-01

    Objective: To evaluate the clinical value of 99 Tc m -methylene diphosphonic acid (MDP) SPECT/CT imaging for the diagnosis of bone metastasis. Methods: Patients suspected for bone metastasis and with bone pain of unknown origin were included in this study (n=237). All cases underwent SPECT and CT imaging at 180 min after 99 Tc m -MDP injection. Diagnosis was confirmed by pathology (n=21), more than 2 kinds of radiologieal imaging (MRI, CT, X-ray) (n=106), and clinical follow up in 2 years (n=110). χ 2 -test was used to compare the results of planar and SPECT/CT imaging using SAS 6.12 software. Results: In 237 patients, planar imaging of 142 cases matched the final diagnosis in which 72 had benign lesions and 70 had bone metastases. The definite coincidence rate was 95.30% (142/149). SPECT/CT imaging of 224 cases matched the final diagnosis in which 104 had benign lesions and 120 cases diagnosed as bone metastases. The coincidence and definite coincidence rates were 94.51% (224/237), and 99.48% (192/193). Difference in the definite coincidence rate between planar and SPECT/CT imaging was statistically significant (χ 2 = 5.37, P=0.024). Conclusion: SPECT/CT imaging is valuable for accurate localization of osseous pathology and for improvement of diagnosing bone metastasis. (authors)

  8. Stereotactic imaging for radiotherapy: accuracy of CT, MRI, PET and SPECT

    International Nuclear Information System (INIS)

    Karger, Christian P; Hipp, Peter; Henze, Marcus; Echner, Gernot; Hoess, Angelika; Schad, Lothar; Hartmann, Guenther H

    2003-01-01

    CT, MRI, PET and SPECT provide complementary information for treatment planning in stereotactic radiotherapy. Stereotactic correlation of these images requires commissioning tests to confirm the localization accuracy of each modality. A phantom was developed to measure the accuracy of stereotactic localization for CT, MRI, PET and SPECT in the head and neck region. To this end, the stereotactically measured coordinates of structures within the phantom were compared with their mechanically defined coordinates. For MRI, PET and SPECT, measurements were performed using two different devices. For MRI, T1- and T2-weighted imaging sequences were applied. For each measurement, the mean radial deviation in space between the stereotactically measured and mechanically defined position of target points was determined. For CT, the mean radial deviation was 0.4 ± 0.2 mm. For MRI, the mean deviations ranged between 0.7 ± 0.2 mm and 1.4 ± 0.5 mm, depending on the MRI device and the imaging sequence. For PET, mean deviations of 1.1 ± 0.5 mm and 2.4 ± 0.3 mm were obtained. The mean deviations for SPECT were 1.6 ± 0.5 mm and 2.0 ± 0.6 mm. The phantom is well suited to determine the accuracy of stereotactic localization with CT, MRI, PET and SPECT in the head and neck region. The obtained accuracy is well below the physical resolution for CT, PET and SPECT, and of comparable magnitude for MRI. Since the localization accuracy may be device dependent, results obtained at one device cannot be generalized to others

  9. Follow-up findings in regional cerebral blood flow (r-CBF)-SPECT in a case of idiopathic childhood hemidystonia. Functional neuroimaging and pathophysiological implications

    International Nuclear Information System (INIS)

    Fiedler, A.; Aderbauer, J.; Segerer, H.; Marienhagen, J.; Bock, E.; Eilles, C.

    1999-01-01

    A 9 1/2-year-old girl suffered from intermitting tremor and jitteriness of her left hand and oral muscles every 4 to 6 weeks with long lasting episodes. Clinically myoclonias and dystonic positioning of the left arm, hand and facial muscles were seen. No evidence of trauma, infection or inborn errors of metabolism was found. Successful therapy with carbamazepine was initiated while L-DOPA failed. An ictal 99m-Tc-HMPAO-SPECT showed severe asymmetry with focal hyperperfusion of the contralateral right thalamus and basal ganglia as well as of the bifrontal cortex, whereas no anatomical lesions were found by MRI. In contrast, an interictally performed 99m-Tc-HMPAO SPECT showed hypoperfusion or the right thalamus and normalisation of the frontal perfusion under medical treatment. These 99m-Tc-HMPAO-SPECT findings may provide new insights into the localisation and pathophysiological pathways of idiopathic childhood dystonia. (orig.) [de

  10. Brain spect in the pre-surgical evaluation of epileptic patients preliminary results

    Directory of Open Access Journals (Sweden)

    Carlos A. Buchpiguel

    1992-03-01

    Full Text Available Pre-surgical evaluation of epileptic patients consists of neurological examination, intensive electroencephalographic (EEG monitoring and anatomical studies (CT and MRI. Functional methods such as PET and SPECT imaging are now used more frequently. We have studied pre-operatively 15 adult epileptic patients (8 female, 7 male using a rotational scintillation camera interfaced to a dedicated computer. The tomographic images were obtained 15 minutes after intravenous injection of 99mTc_HMPAO. All had MRI scanning and intensive EEG monitoring which generally included seizure recording. Five patients had progressive lesions (3 meningiomas, 2 astrocytomas. In 10 patients, neuroradiological studies did not show the presence of progressive lesions (2 normal scans and 8 cases with inactive lesions. Two patients with meningioma showed hypoperfusion at the lesion site while the third patient had a marked hyperperfusion which might correlate with the clinical diagnosis of epilepsia partialis continua. In the astrocytoma patients SPECT scans showed hypoperfusion at the lesion site. Data obtained from the 10 patients without progressive CNS lesions showed: (a in 4, SPECT findings correlated well with the anatomical findings; (b in 5 instances, SPECT was able to disclose additional functional deficits; (c in one case, there was no SPECT correlate of a discrete anatomical lesion. In 5 of these cases with no progressive lesions (n=10 SPECT findings were useful as a complementary tool in determining the clinical or surgical management of these patients. Despite the small number and hete-rogenicity of the present sample, SPECT seems to be an useful tool as part of the clinical workup of epileptic patients who are candidates for epilepsy surgery.

  11. Analysis of brain SPECT with the statistical parametric mapping package SPM99

    International Nuclear Information System (INIS)

    Barnden, L.R.; Rowe, C.C.

    2000-01-01

    Full text: The Statistical Parametric Mapping (SPM) package of the Welcome Department of Cognitive Neurology permits detection in the brain of different regional uptake in an individual subject or a population of subjects compared to a normal population. SPM does not require a-priori specification of regions of interest. Recently SPM has been upgraded from SPM96 to SPM99. Our aim was to vary brain SPECT processing options in the application of SPM to optimise the final statistical map in three clinical trials. The sensitivity of SPM depends on the fidelity of the preliminary spatial normalisation of each scan to the standard anatomical space defined by a template scan provided with SPM. We generated our own SPECT template and compared spatial normalisation to it and to SPM's internal PET template. We also investigated the effects of scatter subtraction, stripping of scalp activity, reconstruction algorithm, non-linear deformation and derivation of spatial normalisation parameters using co-registered MR. Use of our SPECT template yielded better results than with SPM's PET template. Accuracy of SPECT to MR co-registration was 2.5mm with SPM96 and 1.2mm with SPM99. Stripping of scalp activity improved results with SPM96 but was unnecessary with SPM99. Scatter subtraction increased the sensitivity of SPM. Non-linear deformation additional to linear (affine) transformation only marginally improved the final result. Use of the SPECT template yielded more significant results than those obtained when co registered MR was used to derive the transformation parameters. SPM99 is more robust than SPM96 and optimum SPECT analysis requires a SPECT template. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  12. Evaluation of image reconstruction methods for 123I-MIBG-SPECT. A rank-order study

    International Nuclear Information System (INIS)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid; Valind, Sven; Thorsson, Ola; Garpered, Sabine; Prautzsch, Tilmann; Tischenko, Oleg

    2012-01-01

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on 123 I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq 123 I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D 32 > ReSPECT > Flash 3D 64 > OPED, and after 24 h: Flash 3D 16 > ReSPECT > Flash 3D 32 > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D 32 (4 h) and Flash 3D 16 (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of 123 I-MIBG images

  13. New SPECT and PET dementia tracers

    International Nuclear Information System (INIS)

    Vergote, J.; Chalon, S.; Emond, P.; Vercouillie, J.; Guilloteau, D.; Vergote, J.; Guilloteau, D.; Pappata, J.S.

    2009-01-01

    Single photon emission tomography (SPECT) and positron emission tomography (PET) are techniques to study in vivo neurotransmitter systems, neuro inflammation and amyloid deposits in normal human brain and in dementia. These methods used to explore the integrity of dopaminergic, cholinergic and serotonergic systems in Alzheimer's disease and in other dementias allowed to understand how the neurotransmission was modified in these disorders. Progress in the understanding of pathophysiological and clinical signs of dementia requires an evolution of the radioligands used to carry out an increasingly early and differential diagnosis in addition to monitoring the progression of disease and the effects of therapies. New emerging radiotracers for neuro inflammation or amyloid deposits are essential. In this article, new SPECT and PET tracers are presented. (authors)

  14. Tc-99m ECD brain SPECT in MELAS syndrome: comparison with MR finding

    International Nuclear Information System (INIS)

    Park, Sang Joon; Ryu, Young Hoon; Yoon, Pyeong Ho; Jeon, Tae Joo; Kim, Jai Keun; Nam, Ji Eun; Lee, Jong Doo; Lee, Byung Hee; Shin, Hyung Cheol

    1998-01-01

    The purpose of this study was to evaluate SPECT findings of MELAS syndrome and mitochondrial myopathy and correlate them with MR findings in search of specific imaging features and to assess the role of SPECT in MELAS syndrome. Five patients (four females and one male; age range, 1 to 25 years) who presented with repeated stroke-like episodes or seizures or developmental delay or were asymptomatic but had elevated lactic acid in CSF and serum were evaluated with conventional noncontrast MR imaging and SPECT. MRI demonstrated increased T2 signal intensities in the affected areas of gray and white matters mainly on the parietal (4/5) and occipital lobes (4/5) and in the basal ganglias (1/5), which were not restricted to a specific vascular territory. SPECT demonstrated decreased uptake of Tc-99m ECD on parietal (5/5) and occipital (4/5) and temporal (2/5) and frontal (1/5) lobe and basal ganglia (2/5) and thalami (2/5). In a patient with mitochondrial myopathy who had normal MRI, decreased perfusion is noted on left parietal area and bilateral thalami. Comparison of the numbers of abnormal findings revealed that decreased perfusion seen on SPECT were more numerous than anatomical abnormalities seen on MRI. SPECT may be a sensitive method for pathophysiological study of metabolic disturbances in MELAS. Moreover, in patients with mitochondrial myopathy without clinical encephalopathy, SPECT may play a role in evaluating subclinical encephalopathy even with normal conventional MR findings

  15. Quantification in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2005-01-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena; 2 - quantification in SPECT, problems and correction methods: Attenuation, scattering, un-stationary spatial resolution, partial volume effect, movement, tomographic reconstruction, calibration; 3 - Synthesis: actual quantification accuracy; 4 - Beyond the activity concentration measurement

  16. A Comparative Study of SPECT, q-EEG and CT in Patients with Mild, Acute Head Trauma

    International Nuclear Information System (INIS)

    Lee, Suk Ho; Kim, Jin Seok; Moon, Hee Seung

    1993-01-01

    Functional cerebral impairments have been verified objectively by brain SPECT and q-EEG (quantitative electroencephalography). Microcerebral circulatory defects without anatomical changes cannot be detected by the brain CT or MRI. Brain SPECT using 99m Tc-HMPAO (Hexamethyl propyleneamine oxime) as a key radioisotope may be accepted as the useful method for identifying functional cerebral impairments. We studied 25 patients with mild head trauma to define whether the SPECT was helpful in detecting cerebral impairment. The SPECT was positive in 23 patients out of 25, q-EEG positive in 16 patients and brain CT was positive in 3 cases. SPECT and q-EEG were more sensitive than CT. SPECT would be more useful method than brain CT to investigate cerebral function after head injury

  17. Percutaneous radiofrequency ablation of lung tumors: evaluation of the literature using evidence-based techniques.

    LENUS (Irish Health Repository)

    Chan, Victoria O

    2012-02-01

    PURPOSE: The aim of this study was to evaluate the literature for articles assessing radiofrequency ablation (RFA) for pulmonary malignancy. MATERIALS AND METHODS: The "bottom-up" approach to evidence-based practice was applied by 2 reviewers to the retrieval and appraisal of original research articles published on pulmonary RFA between 2002 and 2009. Primary lung cancer and pulmonary metastases data were analyzed separately. The relationship between the percentage of local recurrence rate and lesion size, patient age, follow-up duration, and time to local recurrence was assessed using Spearman\\'s rank correlation. Discrete time series were used to evaluate time trends. RESULTS: Secondary evidence yielded 1 review of 26 observational studies. Primary evidence yielded 46 studies that seemed suitable for detailed appraisal. A total of 2905 ablations were performed in 1584 patients. Eight studies evaluated primary lung cancers alone, 11 evaluated pulmonary metastases alone, 25 evaluated both, and 2 did not specify the histology. Results revealed trends toward increasing use of conscious sedation over general anesthesia, increasing use of multitined probes, decreasing size of nodule selection, and use of positron emission tomography\\/computed tomography as the optimal follow-up tool. Mean morbidity was 24.6%. The most prevalent side effects included pneumothorax (28.3%), pleural effusions (14.8%), and pain (14.1%). Procedure-related mortality ranged from 0 to 5.6, with an overall procedure-related mortality rate of 0.21%. There were 282 (12.2%) local recurrences occurring at a mean of 13 months. The mean overall survival rate was 59.4%, and the cancer-specific survival rate was 82.6%. CONCLUSIONS: This evidence-based practice review of pulmonary RFA shows it to be a promising treatment for pulmonary malignancy in carefully selected patient populations. Studies with higher levels of evidence, including case-control, prospective nonrandomized and randomized trials

  18. Lymphoscintigraphic sentinel node identification in patients with breast cancer: the role of SPECT-CT

    International Nuclear Information System (INIS)

    Lerman, H.; Metser, U.; Lievshitz, G.; Sperber, F.; Shneebaum, S.; Even-Sapir, E.

    2006-01-01

    Lymph node status is a major factor in determining the stage, appropriate therapy and outcome in patients with breast cancer. It is therefore of clinical importance to accurately identify all sentinel nodes (SNs) for each individual tumour before surgery. The purpose of this study was to assess the role of SPECT-CT lymphoscintigraphy in SN identification in patients with breast cancer. Lymphoscintigraphy comprising planar and SPECT-CT acquisition was performed in 157 consecutive patients with breast cancer (mean age 54.7±10.6, range 27-81 years) with a palpable mass (n=100), with a non-palpable mass (n=52) or post lumpectomy (n=5). Planar and SPECT-CT images were interpreted separately and the two imaging techniques were compared with respect to their ability to identify hot nodes. Planar imaging alone was negative for identification of hot nodes in 15% of the patients. SPECT-CT alone was negative in 10% and both techniques were negative in 9% of the patients. Forty-six of the total of 361 (13%) hot nodes identified by lymphoscintigraphy were detected only on SPECT-CT, including 21 nodes obscured by the scattered radiation from the injection site, nine adjacent nodes misinterpreted on planar images as a single node and 16 nodes which were missed on planar images and detected on SPECT data. SPECT-CT detected additional sites of drainage unexpected on planar images, including axillary (n=23 patients), internal mammary (n=5 patients), interpectoral (n=3 patients) and intramammary (n=2 patients) lymph node sites. Fourteen of the 329 (4%) hot lesions seen on planar images were false positive non-nodal sites of uptake that were accurately assessed by SPECT-CT and further validated by surgery. In a single patient, SPECT-CT was negative while planar images identified the SN. (orig.)

  19. The value of SPECT bone scans in diagnosis of patients with zygapophseal joint pain

    International Nuclear Information System (INIS)

    Hu Jiajia; Liang Yu; Li Biao; Zhu Chengmo; Chen Gang; Wang Chao; Tian Weijia; Qu Liumin

    2008-01-01

    Objective: Bone scintigraphy with SPECT of the lumbar spine allows identification of lesions not seen with planar imaging, in patients with chronic low back pain. The aim of this study was to investigate the value of SPECT bone scans in diagnosis of patients with zygapophyseal joint pain. Methods: Thirty-five consecutive patients in Ruijin hospital from July 2006 to March 2007 with low back pain were en- rolled. All patients underwent bone scintigraphy with SPECT. According to the results of SPECT, patients with isotope-uptake joints received injections at the levels where abnormalities were identified on the scan. Patients with negative scans received other treatment (conservative treatment or surgery) but not facet joint injection. Clinical records were collected at 1-, 3-, and 6-month in SPECT-positive group after their initial treatment. And the SPECT-negative group were followed up at 6-month after therapy. Statistical analysis was performed with SPSS 10.0. Patients with SPECT-positive and -negative results were performed with the grouped t-test. Visual analog scales (VAS) were with the paired t-test used in patients with positive scans at before and after treatment. Results: Fifteen cases had facetal uptake of isotope on SPECT bone scans. After facet joint injection, 85.7% patients (12/14, 1 patient was excluded for operation) had improvement in pain score at 1-month, 78.6% (11/14) at 3-month, and 50.0% (7/14) at 6-month. Of 20 negative cases, 3 were treated by surgery and 17 by conservative treatment. All 20 cases were followed up for 6 months and 70.0% (14/20) had long time pain relief. Conclusion: SPECT bone scans are helpful to identify patients with low back pain who would benefit from facet joint injections. (authors)

  20. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    Energy Technology Data Exchange (ETDEWEB)

    Sundstroem, Torbjoern; Riklund, Katrine Aa. [Umeaa University, Umeaa University Hospital, Department of Radiation Sciences, Diagnostic Radiology, Umeaa (Sweden); Elgh, Eva; Naesman, Birgitta [Umeaa University, Department of Community Medicine and Rehabilitation, Geriatric Medicine, Umeaa (Sweden); Larsson, Anne [Umeaa University, Department of Radiation Sciences, Radiation Physics, Umeaa (Sweden); Nyberg, Lars [Umeaa University, Department of Psychology, Umeaa (Sweden)

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2{+-}4.8 years) with mild AD and 18 healthy elderly (69.4{+-}3.9 years) were included in the study. The subjects were injected with{sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF{sup 99m}Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)