  1. Portable system for auscultation and lung sound analysis.

    Science.gov (United States)

    Nabiev, Rustam; Glazova, Anna; Olyinik, Valery; Makarenkova, Anastasiia; Makarenkov, Anatolii; Rakhimov, Abdulvosid; Felländer-Tsai, Li

    2014-01-01

    A portable system for auscultation and lung sound analysis has been developed, including the original electronic stethoscope coupled with mobile devices and special algorithms for the automated analysis of pulmonary sound signals. It's planned that the developed system will be used for monitoring of health status of patients with various pulmonary diseases.

  2. Application of semi-supervised deep learning to lung sound analysis.

    Science.gov (United States)

    Chamberlain, Daniel; Kodgule, Rahul; Ganelin, Daniela; Miglani, Vivek; Fletcher, Richard Ribon

    2016-08-01

    The analysis of lung sounds, collected through auscultation, is a fundamental component of pulmonary disease diagnostics for primary care and general patient monitoring for telemedicine. Despite advances in computation and algorithms, the goal of automated lung sound identification and classification has remained elusive. Over the past 40 years, published work in this field has demonstrated only limited success in identifying lung sounds, with most published studies using only a small numbers of patients (typically Ndeep learning algorithm for automatically classify lung sounds from a relatively large number of patients (N=284). Focusing on the two most common lung sounds, wheeze and crackle, we present results from 11,627 sound files recorded from 11 different auscultation locations on these 284 patients with pulmonary disease. 890 of these sound files were labeled to evaluate the model, which is significantly larger than previously published studies. Data was collected with a custom mobile phone application and a low-cost (US$30) electronic stethoscope. On this data set, our algorithm achieves ROC curves with AUCs of 0.86 for wheeze and 0.74 for crackle. Most importantly, this study demonstrates how semi-supervised deep learning can be used with larger data sets without requiring extensive labeling of data.

  3. Effects of lung elasticity on the sound propagation in the lung

    International Nuclear Information System (INIS)

    Yoneda, Takahiro; Wada, Shigeo; Nakamura, Masanori; Horii, Noriaki; Mizushima, Koichiro

    2011-01-01

    Sound propagation in the lung was simulated for gaining insight into its acoustic properties. A thorax model consisting of lung parenchyma, thoracic bones, trachea and other tissues was made from human CT images. Acoustic nature of the lung parenchyma and bones was expressed with the Biot model of poroelastic material, whereas trachea and tissues were modeled with gas and an elastic material. A point sound source of white noises was placed in the first bifurcation of trachea. The sound propagation in the thorax model was simulated in a frequency domain. The results demonstrated the significant attenuation of sound especially in frequencies larger than 1,000 Hz. Simulations with a stiffened lung demonstrated suppression of the sound attenuation for higher frequencies observed in the normal lung. These results indicate that the normal lung has the nature of a low-pass filter, and stiffening helps the sound at higher frequencies to propagate without attenuations. (author)

  4. Reduction of heart sound interference from lung sound signals using empirical mode decomposition technique.

    Science.gov (United States)

    Mondal, Ashok; Bhattacharya, P S; Saha, Goutam

    2011-01-01

    During the recording time of lung sound (LS) signals from the chest wall of a subject, there is always heart sound (HS) signal interfering with it. This obscures the features of lung sound signals and creates confusion on pathological states, if any, of the lungs. A novel method based on empirical mode decomposition (EMD) technique is proposed in this paper for reducing the undesired heart sound interference from the desired lung sound signals. In this, the mixed signal is split into several components. Some of these components contain larger proportions of interfering signals like heart sound, environmental noise etc. and are filtered out. Experiments have been conducted on simulated and real-time recorded mixed signals of heart sound and lung sound. The proposed method is found to be superior in terms of time domain, frequency domain, and time-frequency domain representations and also in listening test performed by pulmonologist.

  5. Left-Right Asymmetry in Spectral Characteristics of Lung Sounds Detected Using a Dual-Channel Auscultation System in Healthy Young Adults.

    Science.gov (United States)

    Tsai, Jang-Zern; Chang, Ming-Lang; Yang, Jiun-Yue; Kuo, Dar; Lin, Ching-Hsiung; Kuo, Cheng-Deng

    2017-06-07

    Though lung sounds auscultation is important for the diagnosis and monitoring of lung diseases, the spectral characteristics of lung sounds have not been fully understood. This study compared the spectral characteristics of lung sounds between the right and left lungs and between healthy male and female subjects using a dual-channel auscultation system. Forty-two subjects aged 18-22 years without smoking habits and any known pulmonary diseases participated in this study. The lung sounds were recorded from seven pairs of auscultation sites on the chest wall simultaneously. We found that in four out of seven auscultation pairs, the lung sounds from the left lung had a higher total power (P T ) than those from the right lung. The P T of male subjects was higher than that of female ones in most auscultation pairs. The ratio of inspiration power to expiration power (R I/E ) of lung sounds from the right lung was greater than that from the left lung at auscultation pairs on the anterior chest wall, while this phenomenon was reversed at auscultation pairs on the posterior chest wall in combined subjects, and similarly in both male and female subjects. Though the frequency corresponding to maximum power density of lung sounds (F MPD ) from the left and right lungs was not significantly different, the frequency that equally divided the power spectrum of lung sounds (F 50 ) from the left lung was significantly smaller than that from the right lung at auscultation site on the anterior and lateral chest walls, while it was significantly larger than that of from the right lung at auscultation site on the posterior chest walls. In conclusion, significant differences in the P T , F MPD , F 50 , and R I/E between the left and right lungs at some auscultation pairs were observed by using a dual-channel auscultation system in this study. Structural differences between the left and the right lungs, between the female and male subjects, and between anterior and posterior lungs might

  6. Left–Right Asymmetry in Spectral Characteristics of Lung Sounds Detected Using a Dual-Channel Auscultation System in Healthy Young Adults

    Science.gov (United States)

    Tsai, Jang-Zern; Chang, Ming-Lang; Yang, Jiun-Yue; Kuo, Dar; Lin, Ching-Hsiung; Kuo, Cheng-Deng

    2017-01-01

    Though lung sounds auscultation is important for the diagnosis and monitoring of lung diseases, the spectral characteristics of lung sounds have not been fully understood. This study compared the spectral characteristics of lung sounds between the right and left lungs and between healthy male and female subjects using a dual-channel auscultation system. Forty-two subjects aged 18–22 years without smoking habits and any known pulmonary diseases participated in this study. The lung sounds were recorded from seven pairs of auscultation sites on the chest wall simultaneously. We found that in four out of seven auscultation pairs, the lung sounds from the left lung had a higher total power (PT) than those from the right lung. The PT of male subjects was higher than that of female ones in most auscultation pairs. The ratio of inspiration power to expiration power (RI/E) of lung sounds from the right lung was greater than that from the left lung at auscultation pairs on the anterior chest wall, while this phenomenon was reversed at auscultation pairs on the posterior chest wall in combined subjects, and similarly in both male and female subjects. Though the frequency corresponding to maximum power density of lung sounds (FMPD) from the left and right lungs was not significantly different, the frequency that equally divided the power spectrum of lung sounds (F50) from the left lung was significantly smaller than that from the right lung at auscultation site on the anterior and lateral chest walls, while it was significantly larger than that of from the right lung at auscultation site on the posterior chest walls. In conclusion, significant differences in the PT, FMPD, F50, and RI/E between the left and right lungs at some auscultation pairs were observed by using a dual-channel auscultation system in this study. Structural differences between the left and the right lungs, between the female and male subjects, and between anterior and posterior lungs might account for the

  7. Left–Right Asymmetry in Spectral Characteristics of Lung Sounds Detected Using a Dual-Channel Auscultation System in Healthy Young Adults

    Directory of Open Access Journals (Sweden)

    Jang-Zern Tsai

    2017-06-01

    Full Text Available Though lung sounds auscultation is important for the diagnosis and monitoring of lung diseases, the spectral characteristics of lung sounds have not been fully understood. This study compared the spectral characteristics of lung sounds between the right and left lungs and between healthy male and female subjects using a dual-channel auscultation system. Forty-two subjects aged 18–22 years without smoking habits and any known pulmonary diseases participated in this study. The lung sounds were recorded from seven pairs of auscultation sites on the chest wall simultaneously. We found that in four out of seven auscultation pairs, the lung sounds from the left lung had a higher total power (PT than those from the right lung. The PT of male subjects was higher than that of female ones in most auscultation pairs. The ratio of inspiration power to expiration power (RI/E of lung sounds from the right lung was greater than that from the left lung at auscultation pairs on the anterior chest wall, while this phenomenon was reversed at auscultation pairs on the posterior chest wall in combined subjects, and similarly in both male and female subjects. Though the frequency corresponding to maximum power density of lung sounds (FMPD from the left and right lungs was not significantly different, the frequency that equally divided the power spectrum of lung sounds (F50 from the left lung was significantly smaller than that from the right lung at auscultation site on the anterior and lateral chest walls, while it was significantly larger than that of from the right lung at auscultation site on the posterior chest walls. In conclusion, significant differences in the PT, FMPD, F50, and RI/E between the left and right lungs at some auscultation pairs were observed by using a dual-channel auscultation system in this study. Structural differences between the left and the right lungs, between the female and male subjects, and between anterior and posterior lungs might

  8. Using K-Nearest Neighbor Classification to Diagnose Abnormal Lung Sounds

    Directory of Open Access Journals (Sweden)

    Chin-Hsing Chen

    2015-06-01

    Full Text Available A reported 30% of people worldwide have abnormal lung sounds, including crackles, rhonchi, and wheezes. To date, the traditional stethoscope remains the most popular tool used by physicians to diagnose such abnormal lung sounds, however, many problems arise with the use of a stethoscope, including the effects of environmental noise, the inability to record and store lung sounds for follow-up or tracking, and the physician’s subjective diagnostic experience. This study has developed a digital stethoscope to help physicians overcome these problems when diagnosing abnormal lung sounds. In this digital system, mel-frequency cepstral coefficients (MFCCs were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation. Finally, the K-nearest neighbor method was used to classify the lung sounds. The proposed system can also be used for home care: if the percentage of abnormal lung sound frames is > 30% of the whole test signal, the system can automatically warn the user to visit a physician for diagnosis. We also used bend sensors together with an amplification circuit, Bluetooth, and a microcontroller to implement a respiration detector. The respiratory signal extracted by the bend sensors can be transmitted to the computer via Bluetooth to calculate the respiratory cycle, for real-time assessment. If an abnormal status is detected, the device will warn the user automatically. Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications.

  9. Lung and Heart Sounds Analysis: State-of-the-Art and Future Trends.

    Science.gov (United States)

    Padilla-Ortiz, Ana L; Ibarra, David

    2018-01-01

    Lung sounds, which include all sounds that are produced during the mechanism of respiration, may be classified into normal breath sounds and adventitious sounds. Normal breath sounds occur when no respiratory problems exist, whereas adventitious lung sounds (wheeze, rhonchi, crackle, etc.) are usually associated with certain pulmonary pathologies. Heart and lung sounds that are heard using a stethoscope are the result of mechanical interactions that indicate operation of cardiac and respiratory systems, respectively. In this article, we review the research conducted during the last six years on lung and heart sounds, instrumentation and data sources (sensors and databases), technological advances, and perspectives in processing and data analysis. Our review suggests that chronic obstructive pulmonary disease (COPD) and asthma are the most common respiratory diseases reported on in the literature; related diseases that are less analyzed include chronic bronchitis, idiopathic pulmonary fibrosis, congestive heart failure, and parenchymal pathology. Some new findings regarding the methodologies associated with advances in the electronic stethoscope have been presented for the auscultatory heart sound signaling process, including analysis and clarification of resulting sounds to create a diagnosis based on a quantifiable medical assessment. The availability of automatic interpretation of high precision of heart and lung sounds opens interesting possibilities for cardiovascular diagnosis as well as potential for intelligent diagnosis of heart and lung diseases.

  10. Developing a reference of normal lung sounds in healthy Peruvian children.

    Science.gov (United States)

    Ellington, Laura E; Emmanouilidou, Dimitra; Elhilali, Mounya; Gilman, Robert H; Tielsch, James M; Chavez, Miguel A; Marin-Concha, Julio; Figueroa, Dante; West, James; Checkley, William

    2014-10-01

    Lung auscultation has long been a standard of care for the diagnosis of respiratory diseases. Recent advances in electronic auscultation and signal processing have yet to find clinical acceptance; however, computerized lung sound analysis may be ideal for pediatric populations in settings, where skilled healthcare providers are commonly unavailable. We described features of normal lung sounds in young children using a novel signal processing approach to lay a foundation for identifying pathologic respiratory sounds. 186 healthy children with normal pulmonary exams and without respiratory complaints were enrolled at a tertiary care hospital in Lima, Peru. Lung sounds were recorded at eight thoracic sites using a digital stethoscope. 151 (81%) of the recordings were eligible for further analysis. Heavy-crying segments were automatically rejected and features extracted from spectral and temporal signal representations contributed to profiling of lung sounds. Mean age, height, and weight among study participants were 2.2 years (SD 1.4), 84.7 cm (SD 13.2), and 12.0 kg (SD 3.6), respectively; and, 47% were boys. We identified ten distinct spectral and spectro-temporal signal parameters and most demonstrated linear relationships with age, height, and weight, while no differences with genders were noted. Older children had a faster decaying spectrum than younger ones. Features like spectral peak width, lower-frequency Mel-frequency cepstral coefficients, and spectro-temporal modulations also showed variations with recording site. Lung sound extracted features varied significantly with child characteristics and lung site. A comparison with adult studies revealed differences in the extracted features for children. While sound-reduction techniques will improve analysis, we offer a novel, reproducible tool for sound analysis in real-world environments.

  11. Developing a Reference of Normal Lung Sounds in Healthy Peruvian Children

    Science.gov (United States)

    Ellington, Laura E.; Emmanouilidou, Dimitra; Elhilali, Mounya; Gilman, Robert H.; Tielsch, James M.; Chavez, Miguel A.; Marin-Concha, Julio; Figueroa, Dante; West, James

    2018-01-01

    Purpose Lung auscultation has long been a standard of care for the diagnosis of respiratory diseases. Recent advances in electronic auscultation and signal processing have yet to find clinical acceptance; however, computerized lung sound analysis may be ideal for pediatric populations in settings, where skilled healthcare providers are commonly unavailable. We described features of normal lung sounds in young children using a novel signal processing approach to lay a foundation for identifying pathologic respiratory sounds. Methods 186 healthy children with normal pulmonary exams and without respiratory complaints were enrolled at a tertiary care hospital in Lima, Peru. Lung sounds were recorded at eight thoracic sites using a digital stethoscope. 151 (81 %) of the recordings were eligible for further analysis. Heavy-crying segments were automatically rejected and features extracted from spectral and temporal signal representations contributed to profiling of lung sounds. Results Mean age, height, and weight among study participants were 2.2 years (SD 1.4), 84.7 cm (SD 13.2), and 12.0 kg (SD 3.6), respectively; and, 47 % were boys. We identified ten distinct spectral and spectro-temporal signal parameters and most demonstrated linear relationships with age, height, and weight, while no differences with genders were noted. Older children had a faster decaying spectrum than younger ones. Features like spectral peak width, lower-frequency Mel-frequency cepstral coefficients, and spectro-temporal modulations also showed variations with recording site. Conclusions Lung sound extracted features varied significantly with child characteristics and lung site. A comparison with adult studies revealed differences in the extracted features for children. While sound-reduction techniques will improve analysis, we offer a novel, reproducible tool for sound analysis in real-world environments. PMID:24943262

  12. Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows.

    Science.gov (United States)

    Schreur, H J; Sterk, P J; Vanderschoot, J; van Klink, H C; van Vollenhoven, E; Dijkman, J H

    1992-01-01

    BACKGROUND: A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in normal and emphysematous subjects in relation to airflow. METHODS: Eight normal men (45-63 years, FEV1 79-126% predicted) and nine men with severe emphysema (50-70 years, FEV1 14-63% predicted) participated in the study. Emphysema was diagnosed according to pulmonary history, results of lung function tests, and radiographic criteria. All subjects underwent phonopneumography during standardised breathing manoeuvres between 0.5 and 2 1 below total lung capacity with inspiratory and expiratory target airflows of 2 and 1 l/s respectively during 50 seconds. The synchronous measurements included airflow at the mouth and lung volume changes, and lung sounds at four locations on the right chest wall. For each microphone airflow dependent power spectra were computed by using fast Fourier transformation. Lung sound intensity was expressed as log power (in dB) at 200 Hz at inspiratory flow rates of 1 and 2 l/s and at an expiratory flow rate of 1 l/s. RESULTS: Lung sound intensity was well repeatable on two separate days, the intraclass correlation coefficient ranging from 0.77 to 0.94 between the four microphones. The intensity was strongly influenced by microphone location and airflow. There was, however, no significant difference in lung sound intensity at any flow rate between the normal and the emphysema group. CONCLUSION: Airflow standardised lung sound intensity does not differ between normal and emphysematous subjects. This suggests that the auscultatory finding of diminished breath sounds during the regular physical examination in patients with emphysema is due predominantly to airflow limitation. Images PMID:1440459

  13. Analysis of adventitious lung sounds originating from pulmonary tuberculosis.

    Science.gov (United States)

    Becker, K W; Scheffer, C; Blanckenberg, M M; Diacon, A H

    2013-01-01

    Tuberculosis is a common and potentially deadly infectious disease, usually affecting the respiratory system and causing the sound properties of symptomatic infected lungs to differ from non-infected lungs. Auscultation is often ruled out as a reliable diagnostic technique for TB due to the random distribution of the infection and the varying severity of damage to the lungs. However, advancements in signal processing techniques for respiratory sounds can improve the potential of auscultation far beyond the capabilities of the conventional mechanical stethoscope. Though computer-based signal analysis of respiratory sounds has produced a significant body of research, there have not been any recent investigations into the computer-aided analysis of lung sounds associated with pulmonary Tuberculosis (TB), despite the severity of the disease in many countries. In this paper, respiratory sounds were recorded from 14 locations around the posterior and anterior chest walls of healthy volunteers and patients infected with pulmonary TB. The most significant signal features in both the time and frequency domains associated with the presence of TB, were identified by using the statistical overlap factor (SOF). These features were then employed to train a neural network to automatically classify the auscultation recordings into their respective healthy or TB-origin categories. The neural network yielded a diagnostic accuracy of 73%, but it is believed that automated filtering of the noise in the clinics, more training samples and perhaps other signal processing methods can improve the results of future studies. This work demonstrates the potential of computer-aided auscultation as an aid for the diagnosis and treatment of TB.

  14. Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows

    NARCIS (Netherlands)

    Schreur, H. J.; Sterk, P. J.; Vanderschoot, J.; van Klink, H. C.; van Vollenhoven, E.; Dijkman, J. H.

    1992-01-01

    A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in

  15. Classification of lung sounds using higher-order statistics: A divide-and-conquer approach.

    Science.gov (United States)

    Naves, Raphael; Barbosa, Bruno H G; Ferreira, Danton D

    2016-06-01

    Lung sound auscultation is one of the most commonly used methods to evaluate respiratory diseases. However, the effectiveness of this method depends on the physician's training. If the physician does not have the proper training, he/she will be unable to distinguish between normal and abnormal sounds generated by the human body. Thus, the aim of this study was to implement a pattern recognition system to classify lung sounds. We used a dataset composed of five types of lung sounds: normal, coarse crackle, fine crackle, monophonic and polyphonic wheezes. We used higher-order statistics (HOS) to extract features (second-, third- and fourth-order cumulants), Genetic Algorithms (GA) and Fisher's Discriminant Ratio (FDR) to reduce dimensionality, and k-Nearest Neighbors and Naive Bayes classifiers to recognize the lung sound events in a tree-based system. We used the cross-validation procedure to analyze the classifiers performance and the Tukey's Honestly Significant Difference criterion to compare the results. Our results showed that the Genetic Algorithms outperformed the Fisher's Discriminant Ratio for feature selection. Moreover, each lung class had a different signature pattern according to their cumulants showing that HOS is a promising feature extraction tool for lung sounds. Besides, the proposed divide-and-conquer approach can accurately classify different types of lung sounds. The classification accuracy obtained by the best tree-based classifier was 98.1% for classification accuracy on training, and 94.6% for validation data. The proposed approach achieved good results even using only one feature extraction tool (higher-order statistics). Additionally, the implementation of the proposed classifier in an embedded system is feasible. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Towards the standardisation of lung sound nomenclature

    NARCIS (Netherlands)

    Pasterkamp, Hans; Brand, Paul L. P.; Everard, Mark; Garcia-Marcos, Luis; Melbye, Hasse; Priftis, Kostas N.

    Auscultation of the lung remains an essential part of physical examination even though its limitations, particularly with regard to communicating subjective findings, are well recognised. The European Respiratory Society (ERS) Task Force on Respiratory Sounds was established to build a reference

  17. International perception of lung sounds: a comparison of classification across some European borders

    OpenAIRE

    Aviles Solis, Juan Carlos; Vanbelle, Sophie; Halvorsen, Peder Andreas; Francis, Nick; Cals, Jochem W L; Andreeva, Elena A; Marques, Alda; Piirila, Paivi; Pasterkamp, Hans; Melbye, Hasse

    2017-01-01

    Source at http://dx.doi.org/10.1136/bmjresp-2017-000250 Introduction: Lung auscultation is helpful in the diagnosis of lung and heart diseases; however, the diagnostic value of lung sounds may be questioned due to interobserver variation. This situation may also impair clinical research in this area to generate evidence-based knowledge about the role that chest auscultation has in a modern clinical setting. The recording and visual display of lung sounds is a method that is both repeatab...

  18. A comprehensive computational model of sound transmission through the porcine lung.

    Science.gov (United States)

    Dai, Zoujun; Peng, Ying; Henry, Brian M; Mansy, Hansen A; Sandler, Richard H; Royston, Thomas J

    2014-09-01

    A comprehensive computational simulation model of sound transmission through the porcine lung is introduced and experimentally evaluated. This "subject-specific" model utilizes parenchymal and major airway geometry derived from x-ray CT images. The lung parenchyma is modeled as a poroviscoelastic material using Biot theory. A finite element (FE) mesh of the lung that includes airway detail is created and used in comsol FE software to simulate the vibroacoustic response of the lung to sound input at the trachea. The FE simulation model is validated by comparing simulation results to experimental measurements using scanning laser Doppler vibrometry on the surface of an excised, preserved lung. The FE model can also be used to calculate and visualize vibroacoustic pressure and motion inside the lung and its airways caused by the acoustic input. The effect of diffuse lung fibrosis and of a local tumor on the lung acoustic response is simulated and visualized using the FE model. In the future, this type of visualization can be compared and matched with experimentally obtained elastographic images to better quantify regional lung material properties to noninvasively diagnose and stage disease and response to treatment.

  19. 21 CFR 868.2450 - Lung water monitor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung by...

  20. International perception of lung sounds: a comparison of classification across some European borders.

    Science.gov (United States)

    Aviles-Solis, Juan Carlos; Vanbelle, Sophie; Halvorsen, Peder A; Francis, Nick; Cals, Jochen W L; Andreeva, Elena A; Marques, Alda; Piirilä, Päivi; Pasterkamp, Hans; Melbye, Hasse

    2017-01-01

    Lung auscultation is helpful in the diagnosis of lung and heart diseases; however, the diagnostic value of lung sounds may be questioned due to interobserver variation. This situation may also impair clinical research in this area to generate evidence-based knowledge about the role that chest auscultation has in a modern clinical setting. The recording and visual display of lung sounds is a method that is both repeatable and feasible to use in large samples, and the aim of this study was to evaluate interobserver agreement using this method. With a microphone in a stethoscope tube, we collected digital recordings of lung sounds from six sites on the chest surface in 20 subjects aged 40 years or older with and without lung and heart diseases. A total of 120 recordings and their spectrograms were independently classified by 28 observers from seven different countries. We employed absolute agreement and kappa coefficients to explore interobserver agreement in classifying crackles and wheezes within and between subgroups of four observers. When evaluating agreement on crackles (inspiratory or expiratory) in each subgroup, observers agreed on between 65% and 87% of the cases. Conger's kappa ranged from 0.20 to 0.58 and four out of seven groups reached a kappa of ≥0.49. In the classification of wheezes, we observed a probability of agreement between 69% and 99.6% and kappa values from 0.09 to 0.97. Four out of seven groups reached a kappa ≥0.62. The kappa values we observed in our study ranged widely but, when addressing its limitations, we find the method of recording and presenting lung sounds with spectrograms sufficient for both clinic and research. Standardisation of terminology across countries would improve international communication on lung auscultation findings.

  1. International perception of lung sounds : a comparison of classification across some European borders

    NARCIS (Netherlands)

    Aviles-Solis, Juan Carlos; Vanbelle, Sophie; Halvorsen, Peder A; Francis, Nick; Cals, Jochen W L; Andreeva, Elena A; Marques, Alda; Piirilä, Päivi; Pasterkamp, Hans; Melbye, Hasse

    2017-01-01

    Introduction: Lung auscultation is helpful in the diagnosis of lung and heart diseases; however, the diagnostic value of lung sounds may be questioned due to interobserver variation. This situation may also impair clinical research in this area to generate evidence-based knowledge about the role

  2. The effect of methacholine-induced acute airway narrowing on lung sounds in normal and asthmatic subjects

    NARCIS (Netherlands)

    Schreur, H. J.; Vanderschoot, J.; Zwinderman, A. H.; Dijkman, J. H.; Sterk, P. J.

    1995-01-01

    The association between lung sound alterations and airways obstruction has long been recognized in clinical practice, but the precise pathophysiological mechanisms of this relationship have not been determined. Therefore, we examined the changes in lung sounds at well-defined levels of

  3. Lung sound analysis helps localize airway inflammation in patients with bronchial asthma

    Directory of Open Access Journals (Sweden)

    Shimoda T

    2017-03-01

    Full Text Available Terufumi Shimoda,1 Yasushi Obase,2 Yukio Nagasaka,3 Hiroshi Nakano,1 Akiko Ishimatsu,1 Reiko Kishikawa,1 Tomoaki Iwanaga1 1Clinical Research Center, Fukuoka National Hospital, Fukuoka, 2Second Department of Internal Medicine, School of Medicine, Nagasaki University, Nagasaki, 3Kyoto Respiratory Center, Otowa Hospital, Kyoto, Japan Purpose: Airway inflammation can be detected by lung sound analysis (LSA at a single point in the posterior lower lung field. We performed LSA at 7 points to examine whether the technique could identify the location of airway inflammation in patients with asthma. Patients and methods: Breath sounds were recorded at 7 points on the body surface of 22 asthmatic subjects. Inspiration sound pressure level (ISPL, expiration sound pressure level (ESPL, and the expiration-to-inspiration sound pressure ratio (E/I were calculated in 6 frequency bands. The data were analyzed for potential correlation with spirometry, airway hyperresponsiveness (PC20, and fractional exhaled nitric oxide (FeNO. Results: The E/I data in the frequency range of 100–400 Hz (E/I low frequency [LF], E/I mid frequency [MF] were better correlated with the spirometry, PC20, and FeNO values than were the ISPL or ESPL data. The left anterior chest and left posterior lower recording positions were associated with the best correlations (forced expiratory volume in 1 second/forced vital capacity: r=–0.55 and r=–0.58; logPC20: r=–0.46 and r=–0.45; and FeNO: r=0.42 and r=0.46, respectively. The majority of asthmatic subjects with FeNO ≥70 ppb exhibited high E/I MF levels in all lung fields (excluding the trachea and V50%pred <80%, suggesting inflammation throughout the airway. Asthmatic subjects with FeNO <70 ppb showed high or low E/I MF levels depending on the recording position, indicating uneven airway inflammation. Conclusion: E/I LF and E/I MF are more useful LSA parameters for evaluating airway inflammation in bronchial asthma; 7-point lung

  4. Measurement and classification of heart and lung sounds by using LabView for educational use.

    Science.gov (United States)

    Altrabsheh, B

    2010-01-01

    This study presents the design, development and implementation of a simple low-cost method of phonocardiography signal detection. Human heart and lung signals are detected by using a simple microphone through a personal computer; the signals are recorded and analysed using LabView software. Amplitude and frequency analyses are carried out for various phonocardiography pathological cases. Methods for automatic classification of normal and abnormal heart sounds, murmurs and lung sounds are presented. Various cases of heart and lung sound measurement are recorded and analysed. The measurements can be saved for further analysis. The method in this study can be used by doctors as a detection tool aid and may be useful for teaching purposes at medical and nursing schools.

  5. Internal-state analysis in layered artificial neural network trained to categorize lung sounds

    NARCIS (Netherlands)

    Oud, M

    2002-01-01

    In regular use of artificial neural networks, only input and output states of the network are known to the user. Weight and bias values can be extracted but are difficult to interpret. We analyzed internal states of networks trained to map asthmatic lung sound spectra onto lung function parameters.

  6. [Study for lung sound acquisition module based on ARM and Linux].

    Science.gov (United States)

    Lu, Qiang; Li, Wenfeng; Zhang, Xixue; Li, Junmin; Liu, Longqing

    2011-07-01

    A acquisition module with ARM and Linux as a core was developed. This paper presents the hardware configuration and the software design. It is shown that the module can extract human lung sound reliably and effectively.

  7. A Two-Level Sound Classification Platform for Environmental Monitoring

    Directory of Open Access Journals (Sweden)

    Stelios A. Mitilineos

    2018-01-01

    Full Text Available STORM is an ongoing European research project that aims at developing an integrated platform for monitoring, protecting, and managing cultural heritage sites through technical and organizational innovation. Part of the scheduled preventive actions for the protection of cultural heritage is the development of wireless acoustic sensor networks (WASNs that will be used for assessing the impact of human-generated activities as well as for monitoring potentially hazardous environmental phenomena. Collected sound samples will be forwarded to a central server where they will be automatically classified in a hierarchical manner; anthropogenic and environmental activity will be monitored, and stakeholders will be alarmed in the case of potential malevolent behavior or natural phenomena like excess rainfall, fire, gale, high tides, and waves. Herein, we present an integrated platform that includes sound sample denoising using wavelets, feature extraction from sound samples, Gaussian mixture modeling of these features, and a powerful two-layer neural network for automatic classification. We contribute to previous work by extending the proposed classification platform to perform low-level classification too, i.e., classify sounds to further subclasses that include airplane, car, and pistol sounds for the anthropogenic sound class; bird, dog, and snake sounds for the biophysical sound class; and fire, waterfall, and gale for the geophysical sound class. Classification results exhibit outstanding classification accuracy in both high-level and low-level classification thus demonstrating the feasibility of the proposed approach.

  8. Electromagnetic Sampo monitoring soundings at Olkiluoto 2010

    International Nuclear Information System (INIS)

    Korhonen, K.; Korpisalo, A.; Ojamo, H.

    2010-12-01

    The Geological Survey of Finland has carried out electromagnetic frequency-domain depth soundings at fixed measurement stations in Olkiluoto annually since 2004. The purpose of the soundings is to monitor the groundwater conditions in the vicinity of the ONKALO rock characterization facility which will ultimately be part of the final nuclear waste disposal facility for the Finnish nuclear power companies. A new monitoring survey was carried out at the turn of May-June 2010. The survey resulted in 38 successfully performed soundings at 10 stations. The data set spanning the time period of 2004 to 2010 was interpreted with layered-earth models. Most of the interpretations indicate no systematic changes in the level of deep saline groundwater. However, at one station there are indications of a systematic rise in the groundwater level. (orig.)

  9. Application of Clustering Techniques for Lung Sounds to Improve Interpretability and Detection of Crackles

    Directory of Open Access Journals (Sweden)

    Germán D. Sosa

    2015-01-01

    Full Text Available Due to the subjectivity involved currently in pulmonary auscultation process and its diagnostic to evaluate the condition of respiratory airways, this work pretends to evaluate the performance of clustering algorithms such as k-means and DBSCAN to perform a computational analysis of lung sounds aiming to visualize a representation of such sounds that highlights the presence of crackles and the energy associated with them. In order to achieve that goal, Wavelet analysis techniques were used in contrast to traditional frequency analysis given the similarity between the typical waveform for a crackle and the wavelet sym4. Once the lung sound signal with isolated crackles is obtained, the clustering process groups crackles in regions of high density and provides visualization that might be useful for the diagnostic made by an expert. Evaluation suggests that k-means groups crackle more effective than DBSCAN in terms of generated clusters.

  10. Sound at the zoo: Using animal monitoring, sound measurement, and noise reduction in zoo animal management.

    Science.gov (United States)

    Orban, David A; Soltis, Joseph; Perkins, Lori; Mellen, Jill D

    2017-05-01

    A clear need for evidence-based animal management in zoos and aquariums has been expressed by industry leaders. Here, we show how individual animal welfare monitoring can be combined with measurement of environmental conditions to inform science-based animal management decisions. Over the last several years, Disney's Animal Kingdom® has been undergoing significant construction and exhibit renovation, warranting institution-wide animal welfare monitoring. Animal care and science staff developed a model that tracked animal keepers' daily assessments of an animal's physical health, behavior, and responses to husbandry activity; these data were matched to different external stimuli and environmental conditions, including sound levels. A case study of a female giant anteater and her environment is presented to illustrate how this process worked. Associated with this case, several sound-reducing barriers were tested for efficacy in mitigating sound. Integrating daily animal welfare assessment with environmental monitoring can lead to a better understanding of animals and their sensory environment and positively impact animal welfare. © 2017 Wiley Periodicals, Inc.

  11. Assessing and optimizing infra-sound networks to monitor volcanic eruptions

    International Nuclear Information System (INIS)

    Tailpied, Dorianne

    2016-01-01

    Understanding infra-sound signals is essential to monitor compliance with the Comprehensive Nuclear-Test ban Treaty, and also to demonstrate the potential of the global monitoring infra-sound network for civil and scientific applications. The main objective of this thesis is to develop a robust tool to estimate and optimize the performance of any infra-sound network to monitor explosive sources such as volcanic eruptions. Unlike previous studies, the developed method has the advantage to consider realistic atmospheric specifications along the propagation path, source frequency and noise levels at the stations. It allows to predict the attenuation and the minimum detectable source amplitude. By simulating the performances of any infra-sound networks, it is then possible to define the optimal configuration of the network to monitor a specific region, during a given period. When carefully adding a station to the existing network, performance can be improved by a factor of 2. However, it is not always possible to complete the network. A good knowledge of detection capabilities at large distances is thus essential. To provide a more realistic picture of the performance, we integrate the atmospheric longitudinal variability along the infra-sound propagation path in our simulations. This thesis also contributes in providing a confidence index taking into account the uncertainties related to propagation and atmospheric models. At high frequencies, the error can reach 40 dB. Volcanic eruptions are natural, powerful and valuable calibrating sources of infra-sound, worldwide detected. In this study, the well instrumented volcanoes Yasur, in Vanuatu, and Etna, in Italy, offer a unique opportunity to validate our attenuation model. In particular, accurate comparisons between near-field recordings and far-field detections of these volcanoes have helped to highlight the potential of our simulation tool to remotely monitor volcanoes. Such work could significantly help to prevent

  12. Design of Wearable Breathing Sound Monitoring System for Real-Time Wheeze Detection

    Directory of Open Access Journals (Sweden)

    Shih-Hong Li

    2017-01-01

    Full Text Available In the clinic, the wheezing sound is usually considered as an indicator symptom to reflect the degree of airway obstruction. The auscultation approach is the most common way to diagnose wheezing sounds, but it subjectively depends on the experience of the physician. Several previous studies attempted to extract the features of breathing sounds to detect wheezing sounds automatically. However, there is still a lack of suitable monitoring systems for real-time wheeze detection in daily life. In this study, a wearable and wireless breathing sound monitoring system for real-time wheeze detection was proposed. Moreover, a breathing sounds analysis algorithm was designed to continuously extract and analyze the features of breathing sounds to provide the objectively quantitative information of breathing sounds to professional physicians. Here, normalized spectral integration (NSI was also designed and applied in wheeze detection. The proposed algorithm required only short-term data of breathing sounds and lower computational complexity to perform real-time wheeze detection, and is suitable to be implemented in a commercial portable device, which contains relatively low computing power and memory. From the experimental results, the proposed system could provide good performance on wheeze detection exactly and might be a useful assisting tool for analysis of breathing sounds in clinical diagnosis.

  13. Analysis of chewing sounds for dietary monitoring

    NARCIS (Netherlands)

    Amft, O.D.; Stäger, M.; Lukowicz, P.; Tröster, G.

    2005-01-01

    The paper reports the results of the first stage of our work on an automatic dietary monitoring system. The work is part of a large European project on using ubiquitous systems to support healthy lifestyle and cardiovascular disease prevention. We demonstrate that sound from the user's mouth can be

  14. Elecromagnetic Sampo monitoring soundings at Olkiluoto in 2013 with updated interpretations

    International Nuclear Information System (INIS)

    Korhonen, K.

    2014-10-01

    The Geological Survey of Finland (GTK) has carried out electromagnetic depth soundings annually at fixed stations in Olkiluoto since 2004 as part of a monitoring program. The goal of the monitoring program is to detect and monitor changes in the electrical properties of the bedrock in the vicinity of the ONKALO underground research facility which will constitute a part of the final nuclear waste repository. A new Sampo monitoring survey was carried out by GTK in October 2013. The survey consists of 37 soundings performed at 17 measurement stations. The nominal coil separations of 200, 400, 500, 600 and 800 metres were used depending on the station. Layer-model interpretations of soundings at eight selected stations were updated with the new data. The interpretations indicate consistent annual changes. Resistivities be-low stations to the East of the ONKALO facility appear to increase annually. In contrast, resistivities below stations to the West of the ONKALO facility appear to decrease annually. However, these changes need to be considered keeping in mind the uncertainties associated with the data and their interpretations. (orig.)

  15. Pollution monitoring of puget sound with honey bees.

    Science.gov (United States)

    Bromenshenk, J J; Carlson, S R; Simpson, J C; Thomas, J M

    1985-02-08

    To show that honey bees are effective biological monitors of environmental contaminants over large geographic areas, beekeepers of Puget Sound, Washington, collected pollen and bees for chemical analysis. From these data, kriging maps of arsenic, cadmium, and fluoride were generated. Results, based on actual concentrations of contaminants in bee tissues, show that the greatest concentrations of contaminants occur close to Commencement Bay and that honey bees are effective as large-scale monitors.

  16. The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting

    International Nuclear Information System (INIS)

    Marques, Alda; Bruton, Anne; Barney, Anna

    2009-01-01

    Lung sounds provide useful information for assessing and monitoring respiratory patients, but standard auscultation is subjective. Computer aided lung sound analysis (CALSA) enables the quantification and characterisation of added lung sounds (e.g. crackles). At present, little is known about the reliability of these sound characteristics. Therefore, the aim of this study was to explore the reliability of crackle initial deflection width (IDW) and two-cycle deflection (2CD) in a clinical population. Fifty-four subjects (37 bronchiectasis, 17 cystic fibrosis) were recruited from out-patient clinics. Three repeated lung sound recordings were taken at seven anatomical sites with a digital stethoscope connected to a laptop computer. The intra-subject reliability of crackle IDW and 2CD was found to be 'good' to 'excellent', estimated by the analysis of variance, intraclass correlation coefficient (IDW 0.76;0.85, 2CD 0.83;0.94), Bland and Altman 95% limits of agreement (IDW −0.50;0.47 ms, 2CD −2.12;1.87 ms) and smallest real difference (IDW 0.30;0.66 ms, 2CD 1.57;2.42 ms). Crackle 2CD was found to be more reliable than IDW. It is concluded that crackle IDW and 2CD characterized by CALSA have good test–retest reliability. This technique requires further evaluation since CALSA has potential to diagnose or monitor respiratory conditions, and provide an objective physiological measure for respiratory interventions

  17. Interpretation of electromagnetic Sampo monitoring soundings of Olkiluoto

    International Nuclear Information System (INIS)

    Korhonen, K.

    2010-04-01

    The Geological Survey of Finland (GTK) has carried out electromagnetic Sampo soundings at Olkiluoto annually since 2004 commissioned by Posiva. The soundings have been carried out at the same measurement stations every year. The goal of the soundings is to detect any changes in the electrical conditions of the bedrock surrounding the ONKALO underground research facility. This study aims to detect possible changes in the groundwater conditions using modelling. The sensitivity of the Sampo method to changes in the electrical properties and the level of groundwater were investigated as part of this study. The results of the sensitivity investigation indicate that the Sampo method is capable of detecting changes occurring even quite deep in the bedrock. Thus, the usage of the Sampo method to monitor the groundwater conditions is warranted. The plots of apparent resistivity as a function of depth indicate that the area directly above the ONKALO facility is very disturbed electromagnetically. However, most of the soundings to the east and west of ONKALO are of better quality and were interpreted. The results indicate possible changes in the groundwater conditions. The level of saline groundwater may be sinking in the eastern part while it may be rising on the western part. (orig.)

  18. Electromagnetic SAMPO monitoring soundings at Olkiluoto 2011 with updated interpretations

    International Nuclear Information System (INIS)

    Korhonen, K.

    2013-11-01

    The Geological Survey of Finland (GTK) has carried out electromagnetic depth soundings annually at fixed stations in Olkiluoto since 2004 as part of a monitoring programme. The goal of the programme is to detect and monitor changes in the electrical properties of the bedrock above and in the vicinity of the underground nuclear waste disposal facility. A new Sampo monitoring survey was carried out during September-October 2011. The survey resulted in 39 soundings at 17 measurement stations. The nominal coil separations of 200, 400, 500, 600 and 800 meters were used. Eight stations were selected for detailed annual layer-model interpretation. The layer models were based on prior geological and geophysical knowledge of the area. The thicknesses of the layer-model layers were kept fixed whereas their resistivities were solved for each subsequent year independent of each other. Many time series indicate clear trends in electrical resistivity. However, even though the data was carefully corrected and edited, the time series display a fairly large amount of variability increasing the uncertainty of the calculated trends. (orig.)

  19. A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

    Directory of Open Access Journals (Sweden)

    Parsaei H.

    2017-03-01

    Full Text Available Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is unsuitable for observing inaccessible patients in some conditions such as during CT scan. Objective: A wireless electronic esophageal stethoscope is designed for continues auscultation of heart and lung sounds in anesthetized patients. The system consists of a transmitter and a receiver. The former acquires, amplifies and transmits the acquired sound signals to the latter via a frequency modulation transmitter. The receiver demodulates, amplifies, and delivers the received signal to a headphone to be heard by anesthesiologist. Results: The usability and effectiveness of the designed system was qualitatively evaluated by 5 anesthesiologists in Namazi Hospital and Shahid Chamran Hospital, Shiraz, Iran on 30 patients in several operating rooms in different conditions; e.g., when electro surgery instruments are working. Fortunately, the experts on average ranked good quality for the heard heart and lung sounds and very good on the user friendly being of the instrument. Conclusion: Evaluation results demonstrate that the developed system is capable of capturing and transmitting heart and lung sounds successfully. Therefore, it can be used to continuously monitor anesthetized patients’ cardiac and respiratory function. Since via the instrument wireless auscultation is possible, it could be suitable for observing inaccessible patients in several conditions such as during CT scan.

  20. A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

    Science.gov (United States)

    Parsaei, H.; Vakily, A.; Shafiei, A.M.

    2017-01-01

    Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is unsuitable for observing inaccessible patients in some conditions such as during CT scan. Objective: A wireless electronic esophageal stethoscope is designed for continues auscultation of heart and lung sounds in anesthetized patients. The system consists of a transmitter and a receiver. The former acquires, amplifies and transmits the acquired sound signals to the latter via a frequency modulation transmitter. The receiver demodulates, amplifies, and delivers the received signal to a headphone to be heard by anesthesiologist. Results: The usability and effectiveness of the designed system was qualitatively evaluated by 5 anesthesiologists in Namazi Hospital and Shahid Chamran Hospital, Shiraz, Iran on 30 patients in several operating rooms in different conditions; e.g., when electro surgery instruments are working. Fortunately, the experts on average ranked good quality for the heard heart and lung sounds and very good on the user friendly being of the instrument. Conclusion: Evaluation results demonstrate that the developed system is capable of capturing and transmitting heart and lung sounds successfully. Therefore, it can be used to continuously monitor anesthetized patients’ cardiac and respiratory function. Since via the instrument wireless auscultation is possible, it could be suitable for observing inaccessible patients in several conditions such as during CT scan. PMID:28451580

  1. Electromagnetic SAMPO monitoring soundings at OLKILUOTO in 2012 with updated interpretations

    International Nuclear Information System (INIS)

    Korhonen, K.

    2013-11-01

    The Geological Survey of Finland (GTK) has carried out electromagnetic depth soundings annually at fixed stations at Olkiluoto since 2004 as part of a monitoring programme. The goal of the programme is to detect and monitor changes in the electrical properties of the bedrock above and in the vicinity of the ONKALO tunnel which will serve as a part of the future underground nuclear waste disposal facility. A new Sampo monitoring survey was carried out during October 2012. The survey plan of 2011 was slightly modified and 36 soundings at 16 measurement stations were carried out. The nominal coil separations of 200, 400, 500, 600 and 800 meters were used. Interpretations at eight selected stations were updated with the new data. The interpretations indicate consistent statistically significant changes. Annual increases in resistivity were detected at stations to the East of ONKALO while annual decreases in resistivity were detected to the West of ONKALO. However, these changes need to be considered keeping in mind the high degree of uncertainty associated with the data and their interpretations. (orig.)

  2. Non-Contact Monitoring of Heart and Lung Activity by Magnetic Induction Measurement

    Directory of Open Access Journals (Sweden)

    M. Steffen

    2008-01-01

    Full Text Available In many clinical applications, the monitoring of heart and lung activity is of vital importance. State-of-the-art monitoring involves the use of electrodes or other contact based sensors (electrocardiogram (ECG, impedance cardiography (ICG, pulse oximetry or equivalent. With the equipment that is used, side effects like skin irritation, difficult application or additional cabling may occur. In contrast, this paper describes a method for non-contact monitoring of heart and lung activity, which is solely based on magnetic induction. This method allows simultaneous monitoring of heart and lung activity, and has the potential of an integrated application in a personal healthcare scenario. To illustrate the performance, a simple test-setup has been developed and the first results are presented here (some of which have been previously presented on the Poster 2008 [10]. 

  3. Auscultation of the lung: past lessons, future possibilities.

    Science.gov (United States)

    Murphy, R L

    1981-01-01

    Review of the history of auscultation of the lung reveals few scientific investigations. The majority of these have led to inconclusive results. The mechanism of production of normal breath sounds remains uncertain. Hypotheses for the generation of adventitious sounds are unproven. Advances in instrumentation for lung sound recording and analysis have provided little of clinical value. There has been a recent resurgence of interest in lung sounds. Space-age technology has improved methodology for sonic analysis significantly. Lung sounds are complex signals that probably reflect regional lung pathophysiology. If they were understood more clearly important non-invasive diagnostic tools could be devised and the value of clinical auscultation could be improved. A multidisciplinary effort will be required to achieve this. PMID:7268687

  4. Lung Injury; Relates to Real-Time Endoscopic Monitoring of Single Cells Respiratory Health in Lung

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-16-1-0253 TITLE: Lung Injury; Relates to Real- Time Endoscopic Monitoring of Single Cells Respiratory Health in Lung...2017 TYPE OF REPORT: Annual PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 DISTRIBUTION ...STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the author(s

  5. Weight preserving image registration for monitoring disease progression in lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Lo, Pechin Chien Pau; Haseem, Ashraf

    2008-01-01

    We present a new image registration based method for monitoring regional disease progression in longitudinal image studies of lung disease. A free-form image registration technique is used to match a baseline 3D CT lung scan onto a following scan. Areas with lower intensity in the following scan...... the density of lung tissue with respect to local expansion or compression such that the total weight of the lungs is preserved during deformation. Our method provides a good estimation of regional destruction of lung tissue for subjects with a significant difference in inspiration level between CT scans...

  6. Estuarine monitoring programs in the Albemarle Sound study area, North Carolina

    Science.gov (United States)

    Moorman, Michelle; Kolb, Katharine R.; Supak, Stacy

    2014-01-01

    Albemarle Sound was selected in 2012 as one of the two demonstration sites in the Nation to test and improve the design of the National Water Quality Monitoring Council’s National Monitoring Network (NMN) for U.S. Coastal Waters and their tributaries. The goal of the NMN for U.S. coastal waters and tributaries is to provide information about the health of our oceans and coastal ecosystems and inland influences on coastal waters for improved resource management. The NMN is an integrated, multidisciplinary, and multiorganizational program using multiple sources of data and information to augment current monitoring programs.

  7. Monitoring lung contusion in a porcine polytrauma model using EIT: an application study.

    Science.gov (United States)

    Santos, Susana Aguiar; Wembers, Carlos Castelar; Horst, Klemens; Pfeifer, Roman; Simon, Tim-Philipp; Pape, Hans-Christoph; Hildebrand, Frank; Czaplik, Michael; Leonhardt, Steffen; Teichmann, Daniel

    2017-07-26

    Lung contusion is the most common lung injury following blunt chest trauma which, in turn, is associated with high mortality rates (Gavelli et al 2002 Eur. Radiol. 12 1273-94). Lung contusion is characterized by hemorrhage and edema with consecutively reduced compliance. Objective and Approach: In this study, unilateral lung contusion and other traumata were induced in 12 pigs by using a bolt gun machine. To investigate the pathophysiological consequences of lung contusion, information on clinical parameters was collected and monitored regularly while animals were additionally monitored with electrical impedance tomography (EIT) before trauma, and at 4, 24, 48 and 72 h after polytrauma. Statistical analyses showed significant differences between the measurement time points in terms of lung compliance ([Formula: see text]) and in global EIT parameters, such as absolute global impedance (aGlobImp) ([Formula: see text]), tidal impedance variation (TIV) ([Formula: see text]) and the center of ventilation (CoV) ([Formula: see text]). Additionally, distinct analyses for the left (non-injured) and right (injured) lung were also performed. In this context, during the progress of lung contusion, significant changes were found for the injured lung in TIV ([Formula: see text]), global inhomogeneity ([Formula: see text]), regional ventilation delay ([Formula: see text]), CoV ([Formula: see text]) and in regions of non-ventilation (rNoVent) ([Formula: see text]). Furthermore, TIV and rNoVent were capable to differentiate the injured and the contralateral healthy lung at 4 and 24 h after injury (TIV: [Formula: see text] and [Formula: see text]; rNoVent: [Formula: see text] and [Formula: see text]). TIV reached a sensitivity of 82% (specificity of 100%) at 4 h and sensitivity of 82% (specificity of 82%) at 24 h after injury, in detecting lung contusion specific consequences. The results indicate that EIT might be a valuable tool to detect and to monitor lung injuries

  8. Performance monitoring in lung cancer patients pre- and post-chemotherapy using fine-grained electrophysiological measures

    Directory of Open Access Journals (Sweden)

    M. Simó

    Full Text Available No previous event-related potentials (ERPs study has explored the error-related negativity (ERN - an ERP component indexing performance monitoring - associated to cancer and chemotherapy-induced cognitive impairment in a lung cancer population. The aim of this study was to examine differences in performance monitoring in a small-cell lung cancer group (SCLC, C+ 1-month following chemotherapy and two control groups: a non-small cell lung cancer patient group (NSCLC, C− prior to chemotherapy and a healthy control group (HC.Seventeen SCLC (C+ underwent a neuropsychological assessment and an ERP study using a flanker and a stop-signal paradigm. This group was compared to fifteen age-, gender- and education-matched NSCLC (C− and eighteen HC.Between 20 and 30% of patients in both lung cancer groups (C+ and C− met criteria for cognitive impairment. Concerning ERPs, lung cancer patients showed lower overall hit rate and a severe ERN amplitude reduction compared to HC.Lung cancer patients exhibited an abnormal pattern of performance monitoring thus suggesting that chemotherapy and especially cancer itself, may contribute to cognitive deterioration. ERN appeared as an objective laboratory tool sensitive to cognitive dysfunction in cancer population. Keywords: Event-related potentials-ERP, Error-related negativity (ERN, Performance monitoring, Lung cancer, Cognitive impairment, Chemobrain

  9. Heart Sound Localization and Reduction in Tracheal Sounds by Gabor Time-Frequency Masking

    OpenAIRE

    SAATCI, Esra; Akan, Aydın

    2018-01-01

    Background and aim: Respiratorysounds, i.e. tracheal and lung sounds, have been of great interest due to theirdiagnostic values as well as the potential of their use in the estimation ofthe respiratory dynamics (mainly airflow). Thus the aim of the study is topresent a new method to filter the heart sound interference from the trachealsounds. Materials and methods: Trachealsounds and airflow signals were collected by using an accelerometer from 10 healthysubjects. Tracheal sounds were then pr...

  10. Efficiency factors for Phoswich based lung monitor using ICRP Voxel phantoms

    International Nuclear Information System (INIS)

    Manohari, M.; Mathiyarasu, R.; Rajagopal, V.; Jose, M.T.; Venkatraman, B.

    2016-01-01

    The actinide contamination in lungs is measured either using array of HPGe detector or Phoswich based lung monitors. This paper discusses the results obtained during numerical calibration of Phoswich based lung counting system using ICRP VOXEL phantoms. The results are also compared with measured efficiency values obtained using LLNL phantom. The efficiency factors of 241 Am present in the lungs for phoswich detector was simulated using ICRP male voxel phantom and compared with experimentally observed values using LLNL Phantom. The observed deviation is 12%. The efficiency of the same for female subjects was estimated using ICRP female voxel phantom for both supine and posterior geometries

  11. Weight preserving image registration for monitoring disease progression in lung CT.

    Science.gov (United States)

    Gorbunova, Vladlena; Lol, Pechin; Ashraf, Haseem; Dirksen, Asger; Nielsen, Mads; de Bruijne, Marleen

    2008-01-01

    We present a new image registration based method for monitoring regional disease progression in longitudinal image studies of lung disease. A free-form image registration technique is used to match a baseline 3D CT lung scan onto a following scan. Areas with lower intensity in the following scan compared with intensities in the deformed baseline image indicate local loss of lung tissue that is associated with progression of emphysema. To account for differences in lung intensity owing to differences in the inspiration level in the two scans rather than disease progression, we propose to adjust the density of lung tissue with respect to local expansion or compression such that the total weight of the lungs is preserved during deformation. Our method provides a good estimation of regional destruction of lung tissue for subjects with a significant difference in inspiration level between CT scans and may result in a more sensitive measure of disease progression than standard quantitative CT measures.

  12. Sound transmission in porcine thorax through airway insonification.

    Science.gov (United States)

    Peng, Ying; Dai, Zoujun; Mansy, Hansen A; Henry, Brian M; Sandler, Richard H; Balk, Robert A; Royston, Thomas J

    2016-04-01

    Many pulmonary injuries and pathologies may lead to structural and functional changes in the lungs resulting in measurable sound transmission changes on the chest surface. Additionally, noninvasive imaging of externally driven mechanical wave motion in the chest (e.g., using magnetic resonance elastography) can provide information about lung structural property changes and, hence, may be of diagnostic value. In the present study, a comprehensive computational simulation (in silico) model was developed to simulate sound wave propagation in the airways, lung, and chest wall under normal and pneumothorax conditions. Experiments were carried out to validate the model. Here, sound waves with frequency content from 50 to 700 Hz were introduced into airways of five porcine subjects via an endotracheal tube, and transmitted waves were measured by scanning laser Doppler vibrometry at the chest wall surface. The computational model predictions of decreased sound transmission with pneumothorax were consistent with experimental measurements. The in silico model can also be used to visualize wave propagation inside and on the chest wall surface for other pulmonary pathologies, which may help in developing and interpreting diagnostic procedures that utilize sound and vibration.

  13. Sound transmission in porcine thorax through airway insonification

    Science.gov (United States)

    Dai, Zoujun; Mansy, Hansen A.; Henry, Brian M.; Sandler, Richard H.; Balk, Robert A.; Royston, Thomas J.

    2015-01-01

    Many pulmonary injuries and pathologies may lead to structural and functional changes in the lungs resulting in measurable sound transmission changes on the chest surface. Additionally, noninvasive imaging of externally driven mechanical wave motion in the chest (e.g., using magnetic resonance elastography) can provide information about lung structural property changes and, hence, may be of diagnostic value. In the present study, a comprehensive computational simulation (in silico) model was developed to simulate sound wave propagation in the airways, lung, and chest wall under normal and pneumothorax conditions. Experiments were carried out to validate the model. Here, sound waves with frequency content from 50 to 700 Hz were introduced into airways of five porcine subjects via an endotracheal tube, and transmitted waves were measured by scanning laser Doppler vibrometry at the chest wall surface. The computational model predictions of decreased sound transmission with pneumothorax were consistent with experimental measurements. The in silico model can also be used to visualize wave propagation inside and on the chest wall surface for other pulmonary pathologies, which may help in developing and interpreting diagnostic procedures that utilize sound and vibration. PMID:26280512

  14. Monitoring Anthropogenic Ocean Sound from Shipping Using an Acoustic Sensor Network and a Compressive Sensing Approach †

    Science.gov (United States)

    Harris, Peter; Philip, Rachel; Robinson, Stephen; Wang, Lian

    2016-01-01

    Monitoring ocean acoustic noise has been the subject of considerable recent study, motivated by the desire to assess the impact of anthropogenic noise on marine life. A combination of measuring ocean sound using an acoustic sensor network and modelling sources of sound and sound propagation has been proposed as an approach to estimating the acoustic noise map within a region of interest. However, strategies for developing a monitoring network are not well established. In this paper, considerations for designing a network are investigated using a simulated scenario based on the measurement of sound from ships in a shipping lane. Using models for the sources of the sound and for sound propagation, a noise map is calculated and measurements of the noise map by a sensor network within the region of interest are simulated. A compressive sensing algorithm, which exploits the sparsity of the representation of the noise map in terms of the sources, is used to estimate the locations and levels of the sources and thence the entire noise map within the region of interest. It is shown that although the spatial resolution to which the sound sources can be identified is generally limited, estimates of aggregated measures of the noise map can be obtained that are more reliable compared with those provided by other approaches. PMID:27011187

  15. Monitoring of surface chemical and underground nuclear explosions with help of ionospheric radio-sounding above test site

    International Nuclear Information System (INIS)

    Krasnov, V.M.; Drobzheva, Ya.V.

    2000-01-01

    We describe the basic principles, advantages and disadvantages of ionospheric method to monitor surface chemical and underground nuclear explosions. The ionosphere is 'an apparatus' for the infra-sound measurements immediately above the test site. Using remote radio sounding of the ionosphere you can obtain that information. So you carry out the inspection at the test site. The main disadvantage of the ionospheric method is the necessity to sound the ionosphere with radio waves. (author)

  16. Monitoring hydraulic stimulation using telluric sounding

    Science.gov (United States)

    Rees, Nigel; Heinson, Graham; Conway, Dennis

    2018-01-01

    The telluric sounding (TS) method is introduced as a potential tool for monitoring hydraulic fracturing at depth. The advantage of this technique is that it requires only the measurement of electric fields, which are cheap and easy when compared with magnetotelluric measurements. Additionally, the transfer function between electric fields from two locations is essentially the identity matrix for a 1D Earth no matter what the vertical structure. Therefore, changes in the earth resulting from the introduction of conductive bodies underneath one of these sites can be associated with deviations away from the identity matrix, with static shift appearing as a galvanic multiplier at all periods. Singular value decomposition and eigenvalue analysis can reduce the complexity of the resulting telluric distortion matrix to simpler parameters that can be visualised in the form of Mohr circles. This technique would be useful in constraining the lateral extent of resistivity changes. We test the viability of utilising the TS method for monitoring on both a synthetic dataset and for a hydraulic stimulation of an enhanced geothermal system case study conducted in Paralana, South Australia. The synthetic data example shows small but consistent changes in the transfer functions associated with hydraulic stimulation, with grids of Mohr circles introduced as a useful diagnostic tool for visualising the extent of fluid movement. The Paralana electric field data were relatively noisy and affected by the dead band making the analysis of transfer functions difficult. However, changes in the order of 5% were observed from 5 s to longer periods. We conclude that deep monitoring using the TS method is marginal at depths in the order of 4 km and that in order to have meaningful interpretations, electric field data need to be of a high quality with low levels of site noise.[Figure not available: see fulltext.

  17. Listening panel agreement and characteristics of lung sounds digitally recorded from children aged 1–59 months enrolled in the Pneumonia Etiology Research for Child Health (PERCH) case–control study

    Science.gov (United States)

    Park, Daniel E; Watson, Nora L; Buck, W Chris; Bunthi, Charatdao; Devendra, Akash; Ebruke, Bernard E; Elhilali, Mounya; Emmanouilidou, Dimitra; Garcia-Prats, Anthony J; Githinji, Leah; Hossain, Lokman; Madhi, Shabir A; Moore, David P; Mulindwa, Justin; Olson, Dan; Awori, Juliet O; Vandepitte, Warunee P; Verwey, Charl; West, James E; Knoll, Maria D; O'Brien, Katherine L; Feikin, Daniel R; Hammit, Laura L

    2017-01-01

    Introduction Paediatric lung sound recordings can be systematically assessed, but methodological feasibility and validity is unknown, especially from developing countries. We examined the performance of acoustically interpreting recorded paediatric lung sounds and compared sound characteristics between cases and controls. Methods Pneumonia Etiology Research for Child Health staff in six African and Asian sites recorded lung sounds with a digital stethoscope in cases and controls. Cases aged 1–59 months had WHO severe or very severe pneumonia; age-matched community controls did not. A listening panel assigned examination results of normal, crackle, wheeze, crackle and wheeze or uninterpretable, with adjudication of discordant interpretations. Classifications were recategorised into any crackle, any wheeze or abnormal (any crackle or wheeze) and primary listener agreement (first two listeners) was analysed among interpretable examinations using the prevalence-adjusted, bias-adjusted kappa (PABAK). We examined predictors of disagreement with logistic regression and compared case and control lung sounds with descriptive statistics. Results Primary listeners considered 89.5% of 792 case and 92.4% of 301 control recordings interpretable. Among interpretable recordings, listeners agreed on the presence or absence of any abnormality in 74.9% (PABAK 0.50) of cases and 69.8% (PABAK 0.40) of controls, presence/absence of crackles in 70.6% (PABAK 0.41) of cases and 82.4% (PABAK 0.65) of controls and presence/absence of wheeze in 72.6% (PABAK 0.45) of cases and 73.8% (PABAK 0.48) of controls. Controls, tachypnoea, >3 uninterpretable chest positions, crying, upper airway noises and study site predicted listener disagreement. Among all interpretable examinations, 38.0% of cases and 84.9% of controls were normal (p<0.0001); wheezing was the most common sound (49.9%) in cases. Conclusions Listening panel and case–control data suggests our methodology is feasible, likely valid

  18. Usability of Computerized Lung Auscultation-Sound Software (CLASS) for learning pulmonary auscultation.

    Science.gov (United States)

    Machado, Ana; Oliveira, Ana; Jácome, Cristina; Pereira, Marco; Moreira, José; Rodrigues, João; Aparício, José; Jesus, Luis M T; Marques, Alda

    2018-04-01

    The mastering of pulmonary auscultation requires complex acoustic skills. Computer-assisted learning tools (CALTs) have potential to enhance the learning of these skills; however, few have been developed for this purpose and do not integrate all the required features. Thus, this study aimed to assess the usability of a new CALT for learning pulmonary auscultation. Computerized Lung Auscultation-Sound Software (CLASS) usability was assessed by eight physiotherapy students using computer screen recordings, think-aloud reports, and facial expressions. Time spent in each task, frequency of messages and facial expressions, number of clicks and problems reported were counted. The timelines of the three methods used were matched/synchronized and analyzed. The tasks exercises and annotation of respiratory sounds were the ones requiring more clicks (median 132, interquartile range [23-157]; 93 [53-155]; 91 [65-104], respectively) and where most errors (19; 37; 15%, respectively) and problems (n = 7; 6; 3, respectively) were reported. Each participant reported a median of 6 problems, with a total of 14 different problems found, mainly related with CLASS functionalities (50%). Smile was the only facial expression presented in all tasks (n = 54). CLASS is the only CALT available that meets all the required features for learning pulmonary auscultation. The combination of the three usability methods identified advantages/disadvantages of CLASS and offered guidance for future developments, namely in annotations and exercises. This will allow the improvement of CLASS and enhance students' activities for learning pulmonary auscultation skills.

  19. Feasibility of an electronic stethoscope system for monitoring neonatal bowel sounds.

    Science.gov (United States)

    Dumas, Jasmine; Hill, Krista M; Adrezin, Ronald S; Alba, Jorge; Curry, Raquel; Campagna, Eric; Fernandes, Cecilia; Lamba, Vineet; Eisenfeld, Leonard

    2013-09-01

    Bowel dysfunction remains a major problem in neonates. Traditional auscultation of bowel sounds as a diagnostic aid in neonatal gastrointestinal complications is limited by skill and inability to document and reassess. Consequently, we built a unique prototype to investigate the feasibility of an electronic monitoring system for continuous assessment of bowel sounds. We attained approval by the Institutional Review Boards for the investigational study to test our system. The system incorporated a prototype stethoscope head with a built-in microphone connected to a digital recorder. Recordings made over extended periods were evaluated for quality. We also considered the acoustic environment of the hospital, where the stethoscope was used. The stethoscope head was attached to the abdomen with a hydrogel patch designed especially for this purpose. We used the system to obtain recordings from eight healthy, full-term babies. A scoring system was used to determine loudness, clarity, and ease of recognition comparing it to the traditional stethoscope. The recording duration was initially two hours and was increased to a maximum of eight hours. Median duration of attachment was three hours (3.75, 2.68). Based on the scoring, the bowel sound recording was perceived to be as loud and clear in sound reproduction as a traditional stethoscope. We determined that room noise and other noises were significant forms of interference in the recordings, which at times prevented analysis. However, no sound quality drift was noted in the recordings and no patient discomfort was noted. Minimal erythema was observed over the fixation site which subsided within one hour. We demonstrated the long-term recording of infant bowel sounds. Our contributions included a prototype stethoscope head, which was affixed using a specially designed hydrogel adhesive patch. Such a recording can be reviewed and reassessed, which is new technology and an improvement over current practice. The use of this

  20. Water quality monitoring and data collection in the Mississippi sound

    Science.gov (United States)

    Runner, Michael S.; Creswell, R.

    2002-01-01

    The United States Geological Survey and the Mississippi Department of Marine Resources are collecting data on the quality of the water in the Mississippi Sound of the Gulf of Mexico, and streamflow data for its tributaries. The U.S. Geological Survey is collecting continuous water-level data, continuous and discrete water-temperature data, continuous and discrete specific-conductance data, as well as chloride and salinity samples at two locations in the Mississippi Sound and three Corps of Engineers tidal gages. Continuous-discharge data are also being collected at two additional stations on tributaries. The Mississippi Department of Marine Resources collects water samples at 169 locations in the Gulf of Mexico. Between 1800 and 2000 samples are collected annually which are analyzed for turbidity and fecal coliform bacteria. The continuous data are made available real-time through the internet and are being used in conjunction with streamflow data, weather data, and sampling data for the monitoring and management of the oyster reefs, the shrimp fishery and other marine species and their habitats.

  1. Efficacy of lung volume optimization maneuver monitored by optoelectronic pletismography in the management of congenital diaphragmatic hernia

    Directory of Open Access Journals (Sweden)

    G. Lista

    2017-01-01

    We report a case of left CDH with severe lung hypoplasia, managed applying open lung strategy in HFOV (pre-surgery period and in Assist-Control with Volume Guarantee (post-surgery period, guided by SpO2 changes, TcPO2 and TcPCO2 monitoring. Opto-electronic plethysmography was used to measure end-expiratory chest wall volume changes (ΔEEcw related to lung volume variations occurring during pressure changes. OEP confirmed the efficacy of using SpO2 and transcutaneous gas monitoring during this recruitment maneuver.

  2. Nonintrusive gas monitoring in neonatal lungs using diode laser spectroscopy: feasibility study.

    Science.gov (United States)

    Lewander, Märta; Bruzelius, Anders; Svanberg, Sune; Svanberg, Katarina; Fellman, Vineta

    2011-12-01

    A feasibility study on noninvasive, real-time monitoring of gases in lungs of preterm infants is reported, where a laser-spectroscopic technique using diode lasers tuned to oxygen and water vapor absorption lines was employed on realistic tissue phantoms. Our work suggests that the technique could provide a new possibility for surveillance of the lung function of preterm infants, in particular the oxygenation, which is of prime importance in this patient group.

  3. SoundProof: A Smartphone Platform for Wireless Monitoring of Wildlife and Environment

    Science.gov (United States)

    Lukac, M.; Monibi, M.; Lane, M. L.; Howell, L.; Ramanathan, N.; Borker, A.; McKown, M.; Croll, D.; Terschy, B.

    2011-12-01

    We are developing an open-source, low-cost wildlife and environmental monitoring solution based on Android smartphones. Using a smartphone instead of a traditional microcontroller or single board computer has several advantages: smartphones are single integrated devices with multiple radios and a battery; they have a robust software interface which enables customization; and are field-tested by millions of users daily. Consequently, smartphones can improve the cost, configurability, and real-time access to data for environmental monitoring, ultimately replacing existing monitoring solutions which are proprietary, difficult to customize, expensive, and require labor-intensive maintenance. While smartphones can radically change environmental and wildlife monitoring, there are a number of technical challenges to address. We present our smartphone-based platform, SoundProof, discuss the challenges of building an autonomous system based on Android phones, and our ongoing efforts to enable environmental monitoring. Our system is built using robust off-the-shelf hardware and mature open-source software where available, to increase scalability and ease of installation. Key features include: * High-quality acoustic signal collection from external microphones to monitor wildlife populations. * Real-time data access, remote programming, and configuration of the field sensor via wireless cellular or WiFi channels, accessible from a website. * Waterproof packaging and solar charger setup for long-term field deployments. * Rich instrumentation of the end-to-end system to quickly identify and debug problems. * Supplementary mesh networking system with long-range wireless antennae to provide coverage when no cell network is available. We have deployed this system to monitor Rufous Crowned Sparrows on Anacapa Island, Chinese Crested Turns on the Matsu Islands in Taiwan, and Ashy Storm Petrels on South East Farallon Island. We have testbeds at two UC Natural Reserves to field

  4. Broadcast sound technology

    CERN Document Server

    Talbot-Smith, Michael

    1990-01-01

    Broadcast Sound Technology provides an explanation of the underlying principles of modern audio technology. Organized into 21 chapters, the book first describes the basic sound; behavior of sound waves; aspects of hearing, harming, and charming the ear; room acoustics; reverberation; microphones; phantom power; loudspeakers; basic stereo; and monitoring of audio signal. Subsequent chapters explore the processing of audio signal, sockets, sound desks, and digital audio. Analogue and digital tape recording and reproduction, as well as noise reduction, are also explained.

  5. The effect of surgery on lung volume and conventional monitoring parameters in ventilated newborn infants.

    Science.gov (United States)

    Proquitté, H; Freiberger, O; Yilmaz, S; Bamberg, C; Degenhardt, P; Roehr, C C; Wauer, R R; Schmalisch, G

    2010-05-01

    In newborn infants, thoraco-abdominal surgery is a serious intervention with respect to gas exchange and lung mechanics. This prospective clinical study compared surgery-induced changes in functional residual capacity (FRC) and ventilation inhomogeneity (VI) indices with changes in conventional monitoring parameters. Of 29 ventilated newborns (mean weight 2,770+/-864 g at surgery), 13, nine and seven underwent thoracic, abdominal or congenital diaphragmatic hernia (CDH) surgery, respectively. The multiple breath washout (MBWO) technique using heptafluoropropane as tracer gas (Babylog 8000; Dräger, Lübeck, Germany) was performed ventilatory monitoring parameters. FRC decreased in non-CDH infants, while FRC increased and VI indices decreased in CDH infants. Despite improvements, the differences in FRC and VI between CDH and non-CDH infants indicated persistent impaired lung function in CHD infants. MBWO can be advantageously used to measure the effect of surgery on the lung. While FRC and VI indices changed following surgery, conventional monitoring parameters did not.

  6. Albemarle Sound demonstration study of the national monitoring network for US coastal waters and their tributaries

    Science.gov (United States)

    Michelle Moorman; Sharon Fitzgerald; Keith Loftin; Elizabeth Fensin

    2016-01-01

    The U.S. Geological Survey’s (USGS) is implementing a demonstration project in the Albemarle Sound for the National Monitoring Network for U.S. coastal waters and their tributaries. The goal of the National Monitoring Network is to provide information about the health of our oceans and coastal ecosystems and inland influences on coastal waters for improved resource...

  7. Monitoring sound to quantify snoring and sleep apnea severity using a smartphone: proof of concept.

    Science.gov (United States)

    Nakano, Hiroshi; Hirayama, Kenji; Sadamitsu, Yumiko; Toshimitsu, Ayaka; Fujita, Hisayuki; Shin, Shizue; Tanigawa, Takeshi

    2014-01-15

    Habitual snoring is a prevalent condition that is not only a marker of obstructive sleep apnea (OSA) but can also lead to vascular risk. However, it is not easy to check snoring status at home. We attempted to develop a snoring sound monitor consisting of a smartphone alone, which is aimed to quantify snoring and OSA severity. The subjects included 50 patients who underwent diagnostic polysomnography (PSG), of which the data of 10 patients were used for developing the program and that of 40 patients were used for validating the program. A smartphone was attached to the anterior chest wall over the sternum. It acquired ambient sound from the built-in microphone and analyzed it using a fast Fourier transform on a real-time basis. Snoring time measured by the smartphone highly correlated with snoring time measured by PSG (r = 0.93). The top 1 percentile value of sound pressure level (L1) determined by the smartphone correlated with the ambient sound L1 during sleep determined by PSG (r = 0.92). Moreover, the respiratory disturbance index estimated by the smartphone (smart-RDI) highly correlated with the apnea-hypopnea index (AHI) obtained by PSG (r = 0.94). The diagnostic sensitivity and specificity of the smart-RDI for diagnosing OSA (AHI ≥ 15) were 0.70 and 0.94, respectively. A smartphone can be used for effectively monitoring snoring and OSA in a controlled laboratory setting. Use of this technology in a noisy home environment remains unproven, and further investigation is needed.

  8. [Lung auscultation--an overview].

    Science.gov (United States)

    Bürgi, Urs; Huber, Lars Christian

    2015-07-01

    The auscultation of the lungs is - among anamnesis - the most important part in the assessment of patients presenting with pulmonary symptoms. The lung auscultation is reproducible, cost efficient and very helpful to distinguish between differential diagnoses, in particular in emergency situations. Detection and description of lung sounds requires experience and should be performed by strict adherence to the internationally accepted terminology. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Three-dimensional audio-magnetotelluric sounding in monitoring coalbed methane reservoirs

    Science.gov (United States)

    Wang, Nan; Zhao, Shanshan; Hui, Jian; Qin, Qiming

    2017-03-01

    Audio-magnetotelluric (AMT) sounding is widely employed in rapid resistivity delineation of objective geometry in near surface exploration. According to reservoir patterns and electrical parameters obtained in Qinshui Basin, China, two-dimensional and three-dimensional synthetic "objective anomaly" models were designed and inverted with the availability of a modular system for electromagnetic inversion (ModEM). The results revealed that 3-D full impedance inversion yielded the subsurface models closest to synthetic models. One or more conductive targets were correctly recovered. Therefore, conductive aquifers in the study area, including hydrous coalbed methane (CBM) reservoirs, were suggested to be the interpretation signs for reservoir characterization. With the aim of dynamic monitoring of CBM reservoirs, the AMT surveys in continuous years (June 2013-May 2015) were carried out. 3-D inversion results demonstrated that conductive anomalies accumulated around the producing reservoirs at the corresponding depths if CBM reservoirs were in high water production rates. In contrast, smaller conductive anomalies were generally identical with rapid gas production or stopping production of reservoirs. These analyses were in accordance with actual production history of CBM wells. The dynamic traces of conductive anomalies revealed that reservoir water migrated deep or converged in axial parts and wings of folds, which contributed significantly to formations of CBM traps. Then the well spacing scenario was also evaluated based on the dynamic production analysis. Wells distributed near closed faults or flat folds, rather than open faults, had CBM production potential to ascertain stable gas production. Therefore, three-dimensional AMT sounding becomes an attractive option with the ability of dynamic monitoring of CBM reservoirs, and lays a solid foundation of quantitative evaluation of reservoir parameters.

  10. New developments in the surveillance and diagnostics technology for vibration, structure-borne sound and leakage monitoring systems

    International Nuclear Information System (INIS)

    Gloth, Gerrit

    2009-01-01

    Monitoring and diagnostic systems are of main importance for a safe and efficient operation of nuclear power plants. The author describes new developments with respect to vibration monitoring with a functional extension in the time domain for den secondary circuit, the development of a local system for the surveillance of rotating machines, the structure-borne sound monitoring with improvement of event analysis, esp. the loose part locating, leakage monitoring with a complete system for humidity measurement, and the development of a common platform for all monitoring and diagnostic systems, that allows an efficient access for comparison and cross references.

  11. Therapy monitoring using dynamic MRI: Analysis of lung motion and intrathoracic tumor mobility before and after radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Plathow, Christian [Eberhard-Karls University Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Hof, Holger; Kuhn, Sabine [University of Heidelberg, Department of Radiation Therapy, Clinic for Thoracic Diseases, Heidelberg (Germany); Puderbach, Michael; Ley, Sebastian; Biederer, Juergen; Kauczor, Hans-Ulrich [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Claussen, Claus D.; Schaefer, Juergen [Eberhard-Karls University Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Huber, Peter E. [University of Heidelberg, Department of Radiation Therapy, Clinic for Thoracic Diseases, Heidelberg (Germany); German Cancer Research Center, Department of Radiation Oncology, Heidelberg (Germany); Tuengerthal, Siegfried [University of Heidelberg, Department of Radiology, Heidelberg (Germany)

    2006-09-15

    A frequent side effect after radiotherapy of lung tumors is a decrease of pulmonary function accompanied by dyspnea due to developing lung fibrosis. The aim of this study was to monitor lung motion as a correlate of pulmonary function and intrathoracic tumor mobility before and after radiotherapy (RT) using dynamic MRI (dMRI). Thirty-five patients with stage I non-small-cell lung carcinoma were examined using dMRI (trueFISP; three images/s). Tumors were divided into T1 and T2 tumors of the upper, middle and lower lung region (LR). Maximum craniocaudal (CC) lung dimensions and tumor mobility in three dimensions were monitored. Vital capacity (VC) was measured and correlated using spirometry. Before RT, the maximum CC motion of the tumor-bearing hemithorax was 5.2{+-}0.9 cm if the tumor was located in the lower LR (middle LR: 5.5{+-}0.8 cm; upper LR: 6.0{+-}0.6 cm). After RT, lung motion was significantly reduced in the lower LR (P<0.05). Before RT, the maximum CC tumor mobility was significantly higher in tumors of the lower LR 2.5{+-}0.6 vs. 2.0{+-}0.3 cm (middle LR; P<0.05) vs. 0.7{+-}0.2 cm (upper LR; P<0.01). After RT, tumor mobility was significantly reduced in the lower LR (P<0.01) and in T2 tumor patients (P<0.05). VC showed no significant changes. dMRI is capable of monitoring changes in lung motion that were not suspected from spirometry. This might make the treatment of side effects possible at a very early stage. Changes of lung motion and tumor mobility are highly dependent on the tumor localization and tumor diameter. (orig.)

  12. Therapy monitoring using dynamic MRI: Analysis of lung motion and intrathoracic tumor mobility before and after radiotherapy

    International Nuclear Information System (INIS)

    Plathow, Christian; Hof, Holger; Kuhn, Sabine; Puderbach, Michael; Ley, Sebastian; Biederer, Juergen; Kauczor, Hans-Ulrich; Claussen, Claus D.; Schaefer, Juergen; Huber, Peter E.; Tuengerthal, Siegfried

    2006-01-01

    A frequent side effect after radiotherapy of lung tumors is a decrease of pulmonary function accompanied by dyspnea due to developing lung fibrosis. The aim of this study was to monitor lung motion as a correlate of pulmonary function and intrathoracic tumor mobility before and after radiotherapy (RT) using dynamic MRI (dMRI). Thirty-five patients with stage I non-small-cell lung carcinoma were examined using dMRI (trueFISP; three images/s). Tumors were divided into T1 and T2 tumors of the upper, middle and lower lung region (LR). Maximum craniocaudal (CC) lung dimensions and tumor mobility in three dimensions were monitored. Vital capacity (VC) was measured and correlated using spirometry. Before RT, the maximum CC motion of the tumor-bearing hemithorax was 5.2±0.9 cm if the tumor was located in the lower LR (middle LR: 5.5±0.8 cm; upper LR: 6.0±0.6 cm). After RT, lung motion was significantly reduced in the lower LR (P<0.05). Before RT, the maximum CC tumor mobility was significantly higher in tumors of the lower LR 2.5±0.6 vs. 2.0±0.3 cm (middle LR; P<0.05) vs. 0.7±0.2 cm (upper LR; P<0.01). After RT, tumor mobility was significantly reduced in the lower LR (P<0.01) and in T2 tumor patients (P<0.05). VC showed no significant changes. dMRI is capable of monitoring changes in lung motion that were not suspected from spirometry. This might make the treatment of side effects possible at a very early stage. Changes of lung motion and tumor mobility are highly dependent on the tumor localization and tumor diameter. (orig.)

  13. The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study.

    Science.gov (United States)

    Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel; Zoccali, Carmine

    2016-11-07

    Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound-guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre- and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at

  14. Counting efficiency of the lung monitor for sup 2 sup 4 sup 1 Am

    CERN Document Server

    Kinase, S; Sekiguchi, M

    2003-01-01

    The counting efficiencies of two lung monitor systems, phoswich detector system and germanium detector system, were measured for lungs and liver loaded with sup 2 sup 4 sup 1 Am in the Japan Atomic Energy Research Institute (JAERI) phantom. It was found that the germanium detector system for sup 2 sup 4 sup 1 Am loaded lungs counting gives the full-energy peak predominated by the absorption of the gamma-ray photon in a single photoelectric interaction and is less sensitive to sup 2 sup 4 sup 1 Am loaded liver. The sup 2 sup 4 sup 1 Am loaded lung activities could be reasonably estimated using germanium detector system rather than phoswich detector system.

  15. Usefulness of the second heart sound for predicting pulmonary hypertension in patients with interstitial lung disease

    Directory of Open Access Journals (Sweden)

    Sandra de Barros Cobra

    Full Text Available CONTEXT AND OBJECTIVE: P2 hyperphonesis is considered to be a valuable finding in semiological diagnoses of pulmonary hypertension (PH. The aim here was to evaluate the accuracy of the pulmonary component of second heart sounds for predicting PH in patients with interstitial lung disease. DESIGN AND SETTING: Cross-sectional study at the University of Brasilia and Hospital de Base do Distrito Federal. METHODS: Heart sounds were acquired using an electronic stethoscope and were analyzed using phonocardiography. Clinical signs suggestive of PH, such as second heart sound (S2 in pulmonary area louder than in aortic area; P2 > A2 in pulmonary area and P2 present in mitral area, were compared with Doppler echocardiographic parameters suggestive of PH. Sensitivity (S, specificity (Sp and positive (LR+ and negative (LR- likelihood ratios were evaluated. RESULTS: There was no significant correlation between S2 or P2 amplitude and PASP (pulmonary artery systolic pressure (P = 0.185 and 0.115; P= 0.13 and 0.34, respectively. Higher S2 in pulmonary area than in aortic area, compared with all the criteria suggestive of PH, showed S = 60%, Sp= 22%; LR+ = 0.7; LR- = 1.7; while P2> A2 showed S= 57%, Sp = 39%; LR+ = 0.9; LR- = 1.1; and P2 in mitral area showed: S= 68%, Sp = 41%; LR+ = 1.1; LR- = 0.7. All these signals together showed: S= 50%, Sp = 56%. CONCLUSIONS: The semiological signs indicative of PH presented low sensitivity and specificity levels for clinically diagnosing this comorbidity.

  16. Relationship between thoracic auscultation and lung pathology detected by ultrasonography in sheep.

    Science.gov (United States)

    Scott, Phil; Collie, Dave; McGorum, Bruce; Sargison, Neil

    2010-10-01

    The utility of routine auscultation to detect and characterise the nature of a range of superficial lung and pleural pathologies in domestic sheep was assessed using ultrasonographic examination to indicate and localise pathologies pre-mortem. Necropsy examination was then used to fully characterise the nature and extent of the lesions. Auscultation recordings were made from 10 normal sheep with no clinical evidence of respiratory disease and with absence of significant superficial lung pathology, which was confirmed initially by ultrasound examination and subsequently at necropsy examination. A further two sheep with endotoxaemia and 30 sheep with well-defined lung lesions were also examined. Increased audibility of normal lung sounds in 4/10 normal sheep was associated with tachypnoea as a consequence of handling and transport during hot weather and was also observed in the two sheep with endotoxaemia. Moderate to severe coarse crackles detected in all advanced cases of ovine pulmonary adenocarcinoma (n=16) were audible over an area larger than the lesion distribution identified during ultrasound examination, and confirmed later at necropsy. Auscultation did not detect abnormal sounds in any of the five sheep with focal pleural abscesses (up to 10 cm diameter). Unilateral pyothorax caused attenuation of sounds relative to the contra-lateral normal lung in all three sheep with this condition. Marked fibrinous pleurisy caused attenuation of sounds relative to normal areas of lung in six sheep. No sounds resembling the description of pleural frictions rubs were heard in the sheep with marked fibrinous pleurisy (n=6) or associated with focal pleural abscesses (n=5). Routine interpretation of auscultated sound did not allow the presence of superficial lung pathology or its distribution to be accurately defined in the respiratory diseases represented in this study. Copyright © 2009 Elsevier Ltd. All rights reserved.

  17. Short communication. Platform for bee-hives monitoring based on sound analysis. A perpetual warehouse for swarms daily activity

    Energy Technology Data Exchange (ETDEWEB)

    Atauri Mezquida, D.; Llorente Martinez, J.

    2009-07-01

    Bees and beekeeping are suffering a global crisis. Constant information on swarms conditions would be a key to study new diseases like colony collapse disorder and to develop new beekeeping tools to improve the hive management and make it more efficient. A platform for beehives monitoring is presented. It is based on the analysis of the colonies buzz which is registered by a bunch of sensors sending the data to a common database. Data obtained through sound processing shows plenty of patterns and tendency lines related to colonies activities and their conditions. It shows the potential of the sound as a swarm activity gauge. The goal of the platform is the possibility to store information about the swarms activity. The objective is to build a global net of monitored hives covering apiaries with different climates, razes and managements. (Author) 21 refs.

  18. Electrical impedance tomography: A new monitoring of regional distribution of lung ventilation (principle of work and clinical application

    Directory of Open Access Journals (Sweden)

    Vuković Rade

    2017-01-01

    Full Text Available Soon after it's discovery in the 1980s, the Electrical Impedance Tomography (EIT, became the topic of interest, primarily regarding its applicability in different diagnostic procedures and monitoring. EIT is a non-invasive procedure, with no additional harmful radiation, which can be used continuously to monitor regional distribution of ventilation, in contrast to the computerized tomography and other diagnostic procedures that have a single image of the respiratory system and its function. Additionally, EIT allows continuous visualization of the lung function at the patient bedside, with an immediate assessment of the respiratory therapeutic maneuvers effects. The results obtained by EIT are complementary to other pulmonary diagnostic procedures, primarily from radiology. In general, EIT provides additional information to the conventional pulmonary monitoring. Crucial to the implementation of lung protective ventilation concept is to determine the ideal alveolar recruitment, which maintains open and functional alveoli during ventilation, meanwhile carrying a minimal risk for lung injury with excessive breathing volume ('over distension'. EIT may be considered as a good guide for optimal adjustment of respiratory support parameters and selection of the ventilation mode. Nowadays, the technical and technological development, hardware and software improvements and experimental validation of the results in animals and volunteers, have enabled practical clinical use of EIT, a useful monitor of regional distribution of lungs ventilation.

  19. Computerised respiratory sounds can differentiate smokers and non-smokers.

    Science.gov (United States)

    Oliveira, Ana; Sen, Ipek; Kahya, Yasemin P; Afreixo, Vera; Marques, Alda

    2017-06-01

    Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, however it is unknown if it is able to detect changes in the lungs of healthy smokers. This study investigated the differences between computerised respiratory sounds of healthy smokers and non-smokers. Healthy smokers and non-smokers were recruited from a university campus. Respiratory sounds were recorded simultaneously at 6 chest locations (right and left anterior, lateral and posterior) using air-coupled electret microphones. Airflow (1.0-1.5 l/s) was recorded with a pneumotachograph. Breathing phases were detected using airflow signals and respiratory sounds with validated algorithms. Forty-four participants were enrolled: 18 smokers (mean age 26.2, SD = 7 years; mean FEV 1 % predicted 104.7, SD = 9) and 26 non-smokers (mean age 25.9, SD = 3.7 years; mean FEV 1 % predicted 96.8, SD = 20.2). Smokers presented significantly higher frequency at maximum sound intensity during inspiration [(M = 117, SD = 16.2 Hz vs. M = 106.4, SD = 21.6 Hz; t(43) = -2.62, p = 0.0081, d z  = 0.55)], lower expiratory sound intensities (maximum intensity: [(M = 48.2, SD = 3.8 dB vs. M = 50.9, SD = 3.2 dB; t(43) = 2.68, p = 0.001, d z  = -0.78)]; mean intensity: [(M = 31.2, SD = 3.6 dB vs. M = 33.7,SD = 3 dB; t(43) = 2.42, p = 0.001, d z  = 0.75)] and higher number of inspiratory crackles (median [interquartile range] 2.2 [1.7-3.7] vs. 1.5 [1.2-2.2], p = 0.081, U = 110, r = -0.41) than non-smokers. Significant differences between computerised respiratory sounds of smokers and non-smokers have been found. Changes in respiratory sounds are often the earliest sign of disease. Thus, computerised respiratory sounds

  20. Measurement of sound velocity profiles in fluids for process monitoring

    International Nuclear Information System (INIS)

    Wolf, M; Kühnicke, E; Lenz, M; Bock, M

    2012-01-01

    In ultrasonic measurements, the time of flight to the object interface is often the only information that is analysed. Conventionally it is only possible to determine distances or sound velocities if the other value is known. The current paper deals with a novel method to measure the sound propagation path length and the sound velocity in media with moving scattering particles simultaneously. Since the focal position also depends on sound velocity, it can be used as a second parameter. Via calibration curves it is possible to determine the focal position and sound velocity from the measured time of flight to the focus, which is correlated to the maximum of averaged echo signal amplitude. To move focal position along the acoustic axis, an annular array is used. This allows measuring sound velocity locally resolved without any previous knowledge of the acoustic media and without a reference reflector. In previous publications the functional efficiency of this method was shown for media with constant velocities. In this work the accuracy of these measurements is improved. Furthermore first measurements and simulations are introduced for non-homogeneous media. Therefore an experimental set-up was created to generate a linear temperature gradient, which also causes a gradient of sound velocity.

  1. Harmful Algal Bloom Monitoring Data for Puget Sound - SoundToxins: Partnership for Enhanced Monitoring and Emergency Response to Harmful Algal Blooms in Puget Sound

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Toxic outbreaks of species of the dinoflagellate Alexandrium have become pervasive in the Puget Sound region over the last two decades, escalating the threats to...

  2. Lung cancer risk in the electroplating industry in Lombardy, Italy, using the Italian occupational cancer monitoring (OCCAM) information system.

    Science.gov (United States)

    Panizza, Celestino; Bai, Edoardo; Oddone, Enrico; Scaburri, Alessandra; Massari, Stefania; Modonesi, Carlo; Contiero, Paolo; Marinaccio, Alessandro; Crosignani, Paolo

    2012-01-01

    Occupational Cancer Monitoring (OCCAM) is an Italian organization that monitors occupational cancers, by area and industrial sector, by retrieving cases and employment history from official databases. OCCAM previously estimated a relative risk (RR) of lung cancer of about 1.32 among "metal treatment" workers in Lombardy, northern Italy, potentially exposed to chrome and nickel. In the present study, lung cancer risk was estimated among electroplating workers only. Lombardy electroplating companies were identified from descriptions in Social Security files. Lung cancer risk was evaluated from 2001 to 2008 incident cases identified from hospital discharge records. The RR for lung cancer among electroplating workers was 2.03 (90% CI 1.33-3.10, 18 cases) for men; 3.00 (90% CI 1.38-9.03, 4 cases) for women. Electroplaters had higher risks than "metal treatment" workers. Although the risks were due to past exposure, case histories and recent acute effects indicate a present carcinogenic hazard in some Lombardy electroplating factories. Copyright © 2011 Wiley Periodicals, Inc.

  3. Using quantitative breath sound measurements to predict lung function following resection

    Directory of Open Access Journals (Sweden)

    Keus Leendert

    2010-10-01

    Full Text Available Abstract Background Predicting postoperative lung function is important for estimating the risk of complications and long-term disability after pulmonary resection. We investigated the capability of vibration response imaging (VRI as an alternative to lung scintigraphy for prediction of postoperative lung function in patients with intrathoracic malignancies. Methods Eighty-five patients with intrathoracic malignancies, considered candidates for lung resection, were prospectively studied. The projected postoperative (ppo lung function was calculated using: perfusion scintigraphy, ventilation scintigraphy, and VRI. Two sets of assessments made: one for lobectomy and one for pneumonectomy. Clinical concordance was defined as both methods agreeing that either a patient was or was not a surgical candidate based on a ppoFEV1% and ppoDLCO% > 40%. Results Limits of agreement between scintigraphy and VRI for ppo following lobectomy were -16.47% to 15.08% (mean difference = -0.70%;95%CI = -2.51% to 1.12% and for pneumonectomy were -23.79% to 19.04% (mean difference = -2.38%;95%CI = -4.69% to -0.07%. Clinical concordance between VRI and scintigraphy was 73% for pneumonectomy and 98% for lobectomy. For patients who had surgery and postoperative lung function testing (n = 31, ppoFEV1% using scintigraphic methods correlated with measured postoperative values better than projections using VRI, (adjusted R2 = 0.32 scintigraphy; 0.20 VRI, however the difference between methods failed to reach statistical significance. Limits of agreement between measured FEV1% postoperatively and ppoFEV1% based on perfusion scintigraphy were -16.86% to 23.73% (mean difference = 3.44%;95%CI = -0.29% to 7.16%; based on VRI were -19.56% to 28.99% (mean difference = 4.72%;95%CI = 0.27% to 9.17%. Conclusions Further investigation of VRI as an alternative to lung scintigraphy for prediction of postoperative lung function is warranted.

  4. Diode laser spectroscopy for noninvasive monitoring of oxygen in the lungs of newborn infants.

    Science.gov (United States)

    Svanberg, Emilie Krite; Lundin, Patrik; Larsson, Marcus; Åkeson, Jonas; Svanberg, Katarina; Svanberg, Sune; Andersson-Engels, Stefan; Fellman, Vineta

    2016-04-01

    Newborn infants may have pulmonary disorders with abnormal gas distribution, e.g., respiratory distress syndrome. Pulmonary radiography is the clinical routine for diagnosis. Our aim was to investigate a novel noninvasive optical technique for rapid nonradiographic bedside detection of oxygen gas in the lungs of full-term newborn infants. Laser spectroscopy was used to measure contents of oxygen gas (at 760 nm) and of water vapor (at 937 nm) in the lungs of 29 healthy newborn full-term infants (birth weight 2,900-3,900 g). The skin above the lungs was illuminated using two low-power diode lasers and diffusely emerging light was detected with a photodiode. Of the total 390 lung measurements performed, clear detection of oxygen gas was recorded in 60%, defined by a signal-to-noise ratio of >3. In all the 29 infants, oxygen was detected. Probe and detector positions for optimal pulmonary gas detection were determined. There were no differences in signal quality with respect to gender, body side or body weight. The ability to measure pulmonary oxygen content in healthy full-term neonates with this technique suggests that with further development, the method might be implemented in clinical practice for lung monitoring in neonatal intensive care.

  5. Bilateral Tubercular Lung Abscess in a Diabetic Female

    Directory of Open Access Journals (Sweden)

    N.S Neki

    2017-07-01

    Full Text Available Liquefactive necrosis of the lung tissue caused by microbial infection, lung abscess is characterised by formation of cavities containing necrotic debris. In the vast majority of cases of lung abscess, polymicrobial bacteria can be found with predominance of anaerobes. Mycobacterium has been described as a very rare causative agent of community acquired lung abscess. We are presenting a case of middle aged diabetic female, who had bilateral lung abscesses, aetiology of which was established to be tubercular. Astonishing it may sound; based upon extensive web and library search, it's the first case report on tubercular lung abscess in a diabetic from India, and perhaps from the world itself.

  6. Assessment of the applicability of AWJ technique for dismantling the reactor of Fugen. Performance of underwater-cutting thick plate and testing of sound-based monitoring for underwater-cutting process

    International Nuclear Information System (INIS)

    Maruyama, Shin-ichiro; Nishio, Shin-ichi

    2010-01-01

    The reactor of Fugen is characterized by its double-walled pressure tube construction that is composed of pressure tubes and calandria tubes. The reactor dismantlement has been planning on dismantling it under water and the abrasive water jet (AWJ) underwater-cutting method is chosen as an option among simultaneous double tubes cutting technologies. For assessing the applicability of the AWJ cutting technology, a thick plate was cut under water by the small AWJ cutting machine. In addition, since cutting causes muddiness in water, cutting was monitored by the sound-based monitoring system which was adopted as a secondary cutting monitoring method. As a results, it was demonstrated that one-phase cutting was possible under water for a stainless-steel plate with 150mm thickness and that the relationship between cutting depth and capable cutting speed could be predictable. As for the sound-based cutting monitoring, the predictability whether or not cutting would be successful was verified by checking the change of sounds level. (author)

  7. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    Science.gov (United States)

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. WODA Technical Guidance on Underwater Sound from Dredging.

    Science.gov (United States)

    Thomsen, Frank; Borsani, Fabrizio; Clarke, Douglas; de Jong, Christ; de Wit, Pim; Goethals, Fredrik; Holtkamp, Martine; Martin, Elena San; Spadaro, Philip; van Raalte, Gerard; Victor, George Yesu Vedha; Jensen, Anders

    2016-01-01

    The World Organization of Dredging Associations (WODA) has identified underwater sound as an environmental issue that needs further consideration. A WODA Expert Group on Underwater Sound (WEGUS) prepared a guidance paper in 2013 on dredging sound, including a summary of potential impacts on aquatic biota and advice on underwater sound monitoring procedures. The paper follows a risk-based approach and provides guidance for standardization of acoustic terminology and methods for data collection and analysis. Furthermore, the literature on dredging-related sounds and the effects of dredging sounds on marine life is surveyed and guidance on the management of dredging-related sound risks is provided.

  9. Artificial intelligence techniques used in respiratory sound analysis--a systematic review.

    Science.gov (United States)

    Palaniappan, Rajkumar; Sundaraj, Kenneth; Sundaraj, Sebastian

    2014-02-01

    Artificial intelligence (AI) has recently been established as an alternative method to many conventional methods. The implementation of AI techniques for respiratory sound analysis can assist medical professionals in the diagnosis of lung pathologies. This article highlights the importance of AI techniques in the implementation of computer-based respiratory sound analysis. Articles on computer-based respiratory sound analysis using AI techniques were identified by searches conducted on various electronic resources, such as the IEEE, Springer, Elsevier, PubMed, and ACM digital library databases. Brief descriptions of the types of respiratory sounds and their respective characteristics are provided. We then analyzed each of the previous studies to determine the specific respiratory sounds/pathology analyzed, the number of subjects, the signal processing method used, the AI techniques used, and the performance of the AI technique used in the analysis of respiratory sounds. A detailed description of each of these studies is provided. In conclusion, this article provides recommendations for further advancements in respiratory sound analysis.

  10. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  11. A more realistic simulation of the performance of the infra-sound monitoring network

    International Nuclear Information System (INIS)

    Le Pichon, A.; Vergoz, J.; Blanc, E.

    2008-01-01

    The first global maps showing the performance of the infra-sound network of the international monitoring system were set in the nineties. Recent measurement of the background noise by the 36 operating stations combined with advanced models of wind give now a more realistic mapping. It has become possible to validate simulations by measuring real events. For instance the explosion that happened in March 2008 in an ammunition storehouse in Albania was detected till Zalesovo (Russia) 4920 km away. These new simulations confirm the detection capability of the network to detect and localize atmospheric explosions whose energy is over 1 kt. It is also shown that the detection performance are very sensitive to both time and places. (A.C.)

  12. Sound as Popular Culture

    DEFF Research Database (Denmark)

    The wide-ranging texts in this book take as their premise the idea that sound is a subject through which popular culture can be analyzed in an innovative way. From an infant’s gurgles over a baby monitor to the roar of the crowd in a stadium to the sub-bass frequencies produced by sound systems...... in the disco era, sound—not necessarily aestheticized as music—is inextricably part of the many domains of popular culture. Expanding the view taken by many scholars of cultural studies, the contributors consider cultural practices concerning sound not merely as semiotic or signifying processes but as material......, physical, perceptual, and sensory processes that integrate a multitude of cultural traditions and forms of knowledge. The chapters discuss conceptual issues as well as terminologies and research methods; analyze historical and contemporary case studies of listening in various sound cultures; and consider...

  13. An alternative respiratory sounds classification system utilizing artificial neural networks

    Directory of Open Access Journals (Sweden)

    Rami J Oweis

    2015-04-01

    Full Text Available Background: Computerized lung sound analysis involves recording lung sound via an electronic device, followed by computer analysis and classification based on specific signal characteristics as non-linearity and nonstationarity caused by air turbulence. An automatic analysis is necessary to avoid dependence on expert skills. Methods: This work revolves around exploiting autocorrelation in the feature extraction stage. All process stages were implemented in MATLAB. The classification process was performed comparatively using both artificial neural networks (ANNs and adaptive neuro-fuzzy inference systems (ANFIS toolboxes. The methods have been applied to 10 different respiratory sounds for classification. Results: The ANN was superior to the ANFIS system and returned superior performance parameters. Its accuracy, specificity, and sensitivity were 98.6%, 100%, and 97.8%, respectively. The obtained parameters showed superiority to many recent approaches. Conclusions: The promising proposed method is an efficient fast tool for the intended purpose as manifested in the performance parameters, specifically, accuracy, specificity, and sensitivity. Furthermore, it may be added that utilizing the autocorrelation function in the feature extraction in such applications results in enhanced performance and avoids undesired computation complexities compared to other techniques.

  14. Monitoring oiled shorelines in Prince William Sound Alaska, following the Exxon Valdez oil spill

    International Nuclear Information System (INIS)

    Gilfillan, E.S.; Page, D.S.; Harner, E.J.; Boehm, P.D.; Stoker, S.W.

    1993-01-01

    Three types of shoreline monitoring programs were employed to evaluate the recovery of the ecological communities of Prince William Sound (PWS) shorelines after the oil spill: (a) Extensive shoreline surveys conducted (1989--1992) over much of the oiled shoreline to define extent of shoreline oiling and to assess biological conditions; (b) Detailed sampling in 1989 at nonrandomly chosen locations representing a range of oiling conditions (c) Comprehensive shoreline ecology program initiated in 1990 to assess shoreline recovery in Prince William Sound using (1) a rigorous stratified random sampling study design with 64 sites representing 4 shoreline habitats and 4 oiling levels (unoiled, light, moderate, heavy); (2) periodic sampling at 12 nonrandomly chosen sites of particular concern. Biological communities were analyzed to detect differences due to oiling in each of 16 habitat/tide zone combinations. Following the spill, populations of all major species survived as sources for recolonization. Recruitment to oiled shores began in summer 1989. By 1990, shoreline biota in PWS had largely recovered. Estimates of shoreline recovery (biological community indistinguishable from reference) ranged from 91% based on univariate analysis of standard community parameters to 73% based on multivariate correspondence analysis

  15. Offshore dredger sound: source levels, sound maps and risk assessment (abstract)

    NARCIS (Netherlands)

    Jong, C.A.F. de; Ainslie, M.A.; Heinis, F.; Janmaat, J.

    2013-01-01

    The Port of Rotterdam is expanding to meet the growing demand to accommodate large cargo vessels. One of the licensing conditions was the monitoring of the underwater sound produced during its construction, with an emphasis on the establishment of acoustic source levels of the Trailing Suction

  16. Puget Sound Intertidal Habitat Inventory; Puget Sound Ambient Monitoring Program, 1996 (NODC Accession 9900221)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Puget Sound's intertidal areas provide habitat for species of commercial, recreational, biotic, and aesthetic value. Habitat is a critical ecosystem component -- it...

  17. Lung function interpolation by analysis of means of neural-network-supported respiration sounds

    NARCIS (Netherlands)

    Oud, M

    Respiration sounds of individual asthmatic patients were analysed in the scope of the development of a method for computerised recognition of the degree of airways obstruction. Respiration sounds were recorded during laboratory sessions of allergen provoked airways obstruction, during several stages

  18. Usefulness of SCC-antigen for diagnosis and monitoring recurrence and effectiveness of therapies of squamous cell carcinoma of the lung

    International Nuclear Information System (INIS)

    Mino, Naoko; Iio, Atsushi; Ata, Mariko; Murase, Kenya; Kataoka, Masaaki; Ito, Hisao; Ishine, Masahiro; Kawamura, Masashi; Hamamoto, Ken

    1987-01-01

    The serum levels of SCC antigen (squamous cell carcinoma related antigen) were measured in 111 patients with primary lung cancer to assess its clinical usefulness for diagnosis of squamous cell carcinoma and for monitoring recurrence and effectiveness of therapies. Serum SCC antigen level in patients with squamous cell carcinoma of the lung was 5.9 ± 10.4 ng/ml, which was high (p < 0.05) compared with those in normal controls (1.6 ± 0.5 ng/ml), patients with other types of lung cancer (2.4 ± 2.9 ng/ml) or benign disease (1.8 ± 1.1 ng/ml). Studies at various clinical stages of squamous cell carcinoma of the lung showed, however, that the SCC antigen levels were high only in the advanced stages (III and IV), whereas not so high in the earlier stages. These results confirmed that SCC antigen is a relatively specific marker to squamous cell carcinoma in the lung, as reported in the uterine cervix and the esophagus. The SCC antigen levels decreased after operation and more markedly after radiotherapy in dose-dependent manner, corresponding to the reduction of the tumor size. On the other hand, the SCC antigen levels were extremely high in the recurrence. It was concluded that SCC antigen is a useful marker for monitoring recurrence or effectiveness of the therapies of SCC of the lung, although not so for its early diagnosis. (author)

  19. Robust segmentation and retrieval of environmental sounds

    Science.gov (United States)

    Wichern, Gordon

    The proliferation of mobile computing has provided much of the world with the ability to record any sound of interest, or possibly every sound heard in a lifetime. The technology to continuously record the auditory world has applications in surveillance, biological monitoring of non-human animal sounds, and urban planning. Unfortunately, the ability to record anything has led to an audio data deluge, where there are more recordings than time to listen. Thus, access to these archives depends on efficient techniques for segmentation (determining where sound events begin and end), indexing (storing sufficient information with each event to distinguish it from other events), and retrieval (searching for and finding desired events). While many such techniques have been developed for speech and music sounds, the environmental and natural sounds that compose the majority of our aural world are often overlooked. The process of analyzing audio signals typically begins with the process of acoustic feature extraction where a frame of raw audio (e.g., 50 milliseconds) is converted into a feature vector summarizing the audio content. In this dissertation, a dynamic Bayesian network (DBN) is used to monitor changes in acoustic features in order to determine the segmentation of continuously recorded audio signals. Experiments demonstrate effective segmentation performance on test sets of environmental sounds recorded in both indoor and outdoor environments. Once segmented, every sound event is indexed with a probabilistic model, summarizing the evolution of acoustic features over the course of the event. Indexed sound events are then retrieved from the database using different query modalities. Two important query types are sound queries (query-by-example) and semantic queries (query-by-text). By treating each sound event and semantic concept in the database as a node in an undirected graph, a hybrid (content/semantic) network structure is developed. This hybrid network can

  20. Characterization of Cytomegalovirus Lung Infection in Non-HIV Infected Children

    Directory of Open Access Journals (Sweden)

    Sonia M. Restrepo-Gualteros

    2014-05-01

    Full Text Available Cytomegalovirus (CMV is a prevalent pathogen in the immunocompromised host and invasive pneumonia is a feared complication of the virus in this population. In this pediatric case series we characterized CMV lung infection in 15 non-HIV infected children (median age 3 years; IQR 0.2–4.9 years, using current molecular and imaging diagnostic modalities, in combination with respiratory signs and symptoms. The most prominent clinical and laboratory findings included cough (100%, hypoxemia (100%, diffuse adventitious breath sounds (100% and increased respiratory effort (93%. All patients had abnormal lung images characterized by ground glass opacity/consolidation in 80% of cases. CMV was detected in the lung either by CMV PCR in bronchoalveolar lavage (82% detection rate or histology/immunohistochemistry in lung biopsy (100% detection rate. CMV caused respiratory failure in 47% of children infected and the overall mortality rate was 13.3%. Conclusion: CMV pneumonia is a potential lethal disease in non-HIV infected children that requires a high-index of suspicion. Common clinical and radiological patterns such as hypoxemia, diffuse adventitious lung sounds and ground-glass pulmonary opacities may allow early identification of CMV lung infection in the pediatric population, which may lead to prompt initiation of antiviral therapy and better clinical outcomes.

  1. Nano-enabled paper humidity sensor for mobile based point-of-care lung function monitoring.

    Science.gov (United States)

    Bhattacharjee, Mitradip; Nemade, Harshal B; Bandyopadhyay, Dipankar

    2017-08-15

    The frequency of breathing and peak flow rate of exhaled air are necessary parameters to detect chronic obstructive pulmonary diseases (COPDs) such as asthma, bronchitis, or pneumonia. We developed a lung function monitoring point-of-care-testing device (LFM-POCT) consisting of mouthpiece, paper-based humidity sensor, micro-heater, and real-time monitoring unit. Fabrication of a mouthpiece of optimal length ensured that the exhaled air was focused on the humidity-sensor. The resistive relative humidity sensor was developed using a filter paper coated with nanoparticles, which could easily follow the frequency and peak flow rate of the human breathing. Adsorption followed by condensation of the water molecules of the humid air on the paper-sensor during the forced exhalation reduced the electrical resistance of the sensor, which was converted to an electrical signal for sensing. A micro-heater composed of a copper-coil embedded in a polymer matrix helped in maintaining an optimal temperature on the sensor surface. Thus, water condensed on the sensor surface only during forcible breathing and the sensor recovered rapidly after the exhalation was complete by rapid desorption of water molecules from the sensor surface. Two types of real-time monitoring units were integrated into the device based on light emitting diodes (LEDs) and smart phones. The LED based unit displayed the diseased, critical, and fit conditions of the lungs by flashing LEDs of different colors. In comparison, for the mobile based monitoring unit, an application was developed employing an open source software, which established a wireless connectivity with the LFM-POCT device to perform the tests. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Vascular and lung function related to ultrafine and fine particles exposure assessed by personal and indoor monitoring: a cross-sectional study

    DEFF Research Database (Denmark)

    Olsen, Yulia; Karottki, Dorina Gabriela; Jensen, Ditte Marie

    2014-01-01

    -related effects. Methods: Associations between vascular and lung function, inflammation markers and exposure in terms of particle number concentration (PNC; d = 10-300 nm) were studied in a cross-sectional design with personal and home indoor monitoring in the Western Copenhagen Area, Denmark. During 48-h, PNC...... and PM2.5 were monitored in living rooms of 60 homes with 81 non-smoking subjects (30-75 years old), 59 of whom carried personal monitors both when at home and away from home. We measured lung function in terms of the FEV1/FVC ratio, microvascular function (MVF) and pulse amplitude by digital artery...... tonometry, blood pressure and biomarkers of inflammation including C-reactive protein, and leukocyte counts with subdivision in neutrophils, eosinophils, monocytes, and lymphocytes in blood. Results: PNC from personal and stationary home monitoring showed weak correlation (r = 0.15, p = 0.24). Personal UFP...

  3. Assays for predicting and monitoring responses to lung cancer immunotherapy

    International Nuclear Information System (INIS)

    Teixidó, Cristina; Karachaliou, Niki; González-Cao, Maria; Morales-Espinosa, Daniela; Rosell, Rafael

    2015-01-01

    Immunotherapy has become a key strategy for cancer treatment, and two immune checkpoints, namely, programmed cell death 1 (PD-1) and its ligand (PD-L1), have recently emerged as important targets. The interaction blockade of PD-1 and PD-L1 demonstrated promising activity and antitumor efficacy in early phase clinical trials for advanced solid tumors such as non-small cell lung cancer (NSCLC). Many cell types in multiple tissues express PD-L1 as well as several tumor types, thereby suggesting that the ligand may play important roles in inhibiting immune responses throughout the body. Therefore, PD-L1 is a critical immunomodulating component within the lung microenvironment, but the correlation between PD-L1 expression and prognosis is controversial. More evidence is required to support the use of PD-L1 as a potential predictive biomarker. Clinical trials have measured PD-L1 in tumor tissues by immunohistochemistry (IHC) with different antibodies, but the assessment of PD-L1 is not yet standardized. Some commercial antibodies lack specificity and their reproducibility has not been fully evaluated. Further studies are required to clarify the optimal IHC assay as well as to predict and monitor the immune responses of the PD-1/PD-L1 pathway

  4. Adaptive Noise Suppression of Pediatric Lung Auscultations With Real Applications to Noisy Clinical Settings in Developing Countries

    Science.gov (United States)

    Emmanouilidou, Dimitra; McCollum, Eric D.; Park, Daniel E.

    2015-01-01

    Goal Chest auscultation constitutes a portable low-cost tool widely used for respiratory disease detection. Though it offers a powerful means of pulmonary examination, it remains riddled with a number of issues that limit its diagnostic capability. Particularly, patient agitation (especially in children), background chatter, and other environmental noises often contaminate the auscultation, hence affecting the clarity of the lung sound itself. This paper proposes an automated multiband denoising scheme for improving the quality of auscultation signals against heavy background contaminations. Methods The algorithm works on a simple two-microphone setup, dynamically adapts to the background noise and suppresses contaminations while successfully preserving the lung sound content. The proposed scheme is refined to offset maximal noise suppression against maintaining the integrity of the lung signal, particularly its unknown adventitious components that provide the most informative diagnostic value during lung pathology. Results The algorithm is applied to digital recordings obtained in the field in a busy clinic in West Africa and evaluated using objective signal fidelity measures and perceptual listening tests performed by a panel of licensed physicians. A strong preference of the enhanced sounds is revealed. Significance The strengths and benefits of the proposed method lie in the simple automated setup and its adaptive nature, both fundamental conditions for everyday clinical applicability. It can be simply extended to a real-time implementation, and integrated with lung sound acquisition protocols. PMID:25879837

  5. Sound and sound sources

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Wahlberg, Magnus

    2017-01-01

    There is no difference in principle between the infrasonic and ultrasonic sounds, which are inaudible to humans (or other animals) and the sounds that we can hear. In all cases, sound is a wave of pressure and particle oscillations propagating through an elastic medium, such as air. This chapter...... is about the physical laws that govern how animals produce sound signals and how physical principles determine the signals’ frequency content and sound level, the nature of the sound field (sound pressure versus particle vibrations) as well as directional properties of the emitted signal. Many...... of these properties are dictated by simple physical relationships between the size of the sound emitter and the wavelength of emitted sound. The wavelengths of the signals need to be sufficiently short in relation to the size of the emitter to allow for the efficient production of propagating sound pressure waves...

  6. Gefinex 400S (SAMPO) EM-soundings at Olkiluoto 2009

    International Nuclear Information System (INIS)

    Jokinen, T.; Lehtimaeki, J.; Korhonen, K.

    2009-09-01

    In the beginning of June 2009 Geological Survey of Finland (GTK) carried out electromagnetic (EM) frequency soundings with Gefinex 400S equipment (Sampo) in the vicinity of ONKALO at the Olkiluoto site investigation area. The EM-monitoring sounding program started in 2004 and has been repeated since yearly in the same season. The aim of the study is to monitor the variations of the groundwater properties down to 500 m depth by the changes of the electric conductivity of the earth at ONKALO and repository area. The original measurement grid was based on two 1400 m long broadside profiles, which have 200 m mutual distance and 200 m station separation. The receiver and transmitter sites are marked with stakes and the profiles were measured using 200, 500, and 800 m coil separations. The measurement program was revised in 2007 and then again in 2009. Now 15 noisy soundings were removed from the program and 3 new points were selected from the area to the east from ONKALO. The new receiver/transmitter sites, called ABC-points were marked with stakes and the points were measured using transmitter-receiver separations 200, 400 and 800 meters. In 2009 the new EM-Sampo monitoring program included 28+9 soundings. The numerous power lines and cables in the area generate local disturbances on the sounding curves, but the SN (signal to noise) ratio and the repeatability of the results is reasonably good even with long coil separations. However, most suitable for monitoring purposes are the sites without strong shallow 3D effects. Comparison of the new results to old 2004-2008 surveys shows differences on some ARD (apparent resistivity-depth) curves. Those are mainly results of the modified shallow structures. The changes in groundwater conditions based on the monitoring results seem insignificant. (orig.)

  7. 77 FR 19301 - Prince William Sound Regional Citizens' Advisory Council Charter Renewal

    Science.gov (United States)

    2012-03-30

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [USCG-2012-0099] Prince William Sound Regional... Prince William Sound Regional Citizens' Advisory Council (PWSRCAC) as an alternative voluntary advisory group for Prince William Sound, Alaska. This certification allows the PWSRCAC to monitor the activities...

  8. Enviromental contaminants in Puget Sound fish - Histological Preparation and Chemical Analyses of Puget Sound Fish

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — As part of a long-term contaminant-monitoring program of fish in Puget Sound and Georgia Basin, Washington Department of Fish and Wildlife (WDFW) and NWFSC have...

  9. Applying cybernetic technology to diagnose human pulmonary sounds.

    Science.gov (United States)

    Chen, Mei-Yung; Chou, Cheng-Han

    2014-06-01

    Chest auscultation is a crucial and efficient method for diagnosing lung disease; however, it is a subjective process that relies on physician experience and the ability to differentiate between various sound patterns. Because the physiological signals composed of heart sounds and pulmonary sounds (PSs) are greater than 120 Hz and the human ear is not sensitive to low frequencies, successfully making diagnostic classifications is difficult. To solve this problem, we constructed various PS recognition systems for classifying six PS classes: vesicular breath sounds, bronchial breath sounds, tracheal breath sounds, crackles, wheezes, and stridor sounds. First, we used a piezoelectric microphone and data acquisition card to acquire PS signals and perform signal preprocessing. A wavelet transform was used for feature extraction, and the PS signals were decomposed into frequency subbands. Using a statistical method, we extracted 17 features that were used as the input vectors of a neural network. We proposed a 2-stage classifier combined with a back-propagation (BP) neural network and learning vector quantization (LVQ) neural network, which improves classification accuracy by using a haploid neural network. The receiver operating characteristic (ROC) curve verifies the high performance level of the neural network. To expand traditional auscultation methods, we constructed various PS diagnostic systems that can correctly classify the six common PSs. The proposed device overcomes the lack of human sensitivity to low-frequency sounds and various PS waves, characteristic values, and a spectral analysis charts are provided to elucidate the design of the human-machine interface.

  10. Sound pressure level tools design used in occupational health by means of Labview software

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2015-01-01

    Conclusion: LabVIEW programming capabilities in the field of sound can be referred to the measurement of sound, frequency analysis, and sound control that actually the software acts like a sound level meter and sound analyzer. According to the mentioned features, we can use this software to analyze and process sound and vibration as a monitoring system.

  11. Ethically sound technology? Guidelines for interactive ethical assessment of personal health monitoring.

    Science.gov (United States)

    Palm, Elin; Nordgren, Anders; Verweij, Marcel; Collste, Göran

    2013-01-01

    Novel care-technologies possess a transformational potential. Future care and support may be provided via monitoring technologies such as smart devices, sensors, actors (robots) and Information and Communication Technologies. Such technologies enable care provision outside traditional care institutions, for instance in the homes of patients. Health monitoring may become "personalized" i.e. tailored to the needs of individual care recipients' but may also alter relations between care providers and care recipents, shape and form the care environment and influence values central to health-care. Starting out from a social constructivist theory of technology, an interactive ethical assessment-model is offered. The suggested model supplements a traditional analysis based on normative ethical theory (top-down approach) with interviews including relevant stakeholders (a bottom-up approach). This method has been piloted by small-scale interviews encircling stakeholder perspectives on three emerging technologies: (1) Careousel, a smart medicine-management device, (2) Robot Giraff, an interactive and mobile communication-device and (3) I-Care, a care-software that combines alarm and register system. By incorporating stakeholder perspectives into the analysis, the interactive ethical assessment model provides a richer understanding of the impact of PHM-technologies on ethical values than a traditional top-down model. If the assessment is conducted before the technology has reached the market - preferably in close interaction with developers and users - ethically sound technologies may be obtained.

  12. Design, development and test of the gearbox condition monitoring system using sound signal processing

    Directory of Open Access Journals (Sweden)

    M Zamani

    2016-09-01

    Full Text Available Introduction One of the ways used for minimizing the cost of maintenance and repairs of rotating industrial equipment is condition monitoring using acoustic analysis. One of the most important problems which always have been under consideration in industrial equipment application is confidence possibility. Each dynamic, electrical, hydraulic or thermal system has certain characteristics which show the normal condition of the machine during function. Any changes of the characteristics can be a signal of a problem in the machine. The aim of condition monitoring is system condition determination using measurements of the signals of characteristics and using this information for system impairment prognostication. There are a lot of ways for condition monitoring of different systems, but sound analysis is accepted and used extensively as a method for condition investigation of rotating machines. The aim of this research is the design and construction of considered gearbox and using of obtaining data in frequency and time spectrum in order to analyze the sound and diagnosis. Materials and Methods This research was conducted at the department of mechanical biosystem workshop at Aboureihan College at Tehran University in February 15th.2015. In this research, in order to investigate the trend of diagnosis and gearbox condition, a system was designed and then constructed. The sound of correct and damaged gearbox was investigated by audiometer and stored in computer for data analysis. Sound measurement was done in three pinions speed of 749, 1050 and 1496 rpm and for correct gearboxes, damage of the fracture of a tooth and a tooth wear. Gearbox design and construction: In order to conduct the research, a gearbox with simple gearwheels was designed according to current needs. Then mentioned gearbox and its accessories were modeled in CATIA V5-R20 software and then the system was constructed. Gearbox is a machine that is used for mechanical power transition

  13. Incore monitoring device

    International Nuclear Information System (INIS)

    Tai, Ichiro; Shirayama, Shin-pei; Nozaki, Shin-ichi.

    1978-01-01

    Purpose: To provide an incore monitoring device wherein both radiation monitoring and acoustic monitoring are carried out simultaneously by one detector, whereby installation of the device and signal pick-up are facilitated. Incore conditions are accurately grasped. Constitution: When a neutron is irradiated in a state where a DC voltage is applied between the electrode and the vessel in the device, an ionization current is occured by (n.γ) reaction of the transformed substance as in an ionization chamber, Accordingly, a voltage drop occurs at both ends of the resistor of the radiation signal processing system, as a result of which a neutron flux can be detected. Further, when a sound is generated in the reactor, the monitoring device bottom wall which formed by a piezoelectric element detects the sound-waves. This output signal is picked up by the acoustic signal processing system to judge the generation of sound. (Aizawa, K.)

  14. A stethoscope with wavelet separation of cardiac and respiratory sounds for real time telemedicine implemented on field-programmable gate array

    Science.gov (United States)

    Castro, Víctor M.; Muñoz, Nestor A.; Salazar, Antonio J.

    2015-01-01

    Auscultation is one of the most utilized physical examination procedures for listening to lung, heart and intestinal sounds during routine consults and emergencies. Heart and lung sounds overlap in the thorax. An algorithm was used to separate them based on the discrete wavelet transform with multi-resolution analysis, which decomposes the signal into approximations and details. The algorithm was implemented in software and in hardware to achieve real-time signal separation. The heart signal was found in detail eight and the lung signal in approximation six. The hardware was used to separate the signals with a delay of 256 ms. Sending wavelet decomposition data - instead of the separated full signa - allows telemedicine applications to function in real time over low-bandwidth communication channels.

  15. Gefinex 400S (Sampo) EM-Soundings at Olkiluoto 2006

    International Nuclear Information System (INIS)

    Jokinen, T.; Lehtimaeki, J.

    2006-08-01

    In the beginning of summer 2006 Geological Survey of Finland carried out electromagnetic frequency soundings with Gefinex 400S equipment (called also Sampo) at Onkalo situated in Olkiluoto nuclear power plant area. The same soundings sites were the first time measured and marked in 2004 and repeated in 2005. The aim of the measurements is to monitor the changes of groundwater conditions by the changes of the electric conductivity of the earth at ONKALO and repository area. The measurements form two 1400 m long broadside profiles, which have 200 m mutual distance and 200 m station separation. The profiles have been measured using 200, 500, and 800 m coil separations. The total number of the soundings was 48 but at 8 stations the measurement did not succeed because of strong electromagnetic noise. The numerous power lines and the cables of the area generate local 3-D effects on the sounding curves, but the repeatability of the results is good. However, most suitable for monitoring purposes are the sites without strong 3-D effects. Comparison of results 2004-2006 shows small differences at some sounding sites. (orig.)

  16. 75 FR 16159 - Prince William Sound Regional Citizens' Advisory Council (PWSRCAC) Charter Renewal

    Science.gov (United States)

    2010-03-31

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [USCG-2010-0121] Prince William Sound Regional... the Prince William Sound Regional Citizens' Advisory Council (PWSRCAC) as an alternative voluntary advisory group for Prince William Sound, Alaska. This certification allows the PWSRCAC to monitor the...

  17. Accuracy of near-patient vs. inbuilt spirometry for monitoring tidal volumes in an in-vitro paediatric lung model.

    Science.gov (United States)

    Morgenroth, S; Thomas, J; Cannizzaro, V; Weiss, M; Schmidt, A R

    2018-03-01

    Spirometric monitoring provides precise measurement and delivery of tidal volumes within a narrow range, which is essential for lung-protective strategies that aim to reduce morbidity and mortality in mechanically-ventilated patients. Conventional anaesthesia ventilators include inbuilt spirometry to monitor inspiratory and expiratory tidal volumes. The GE Aisys CS 2 anaesthesia ventilator allows additional near-patient spirometry via a sensor interposed between the proximal end of the tracheal tube and the respiratory tubing. Near-patient and inbuilt spirometry of two different GE Aisys CS 2 anaesthesia ventilators were compared in an in-vitro study. Assessments were made of accuracy and variability in inspiratory and expiratory tidal volume measurements during ventilation of six simulated paediatric lung models using the ASL 5000 test lung. A total of 9240 breaths were recorded and analysed. Differences between inspiratory tidal volumes measured with near-patient and inbuilt spirometry were most significant in the newborn setting (p tidal volume measurements with near-patient spirometry were consistently more accurate than with inbuilt spirometry for all lung models (p tidal volumes decreased with increasing tidal volumes, and was smaller with near-patient than with inbuilt spirometry. The variability in measured tidal volumes was higher during expiration, especially with inbuilt spirometry. In conclusion, the present in-vitro study shows that measurements with near-patient spirometry are more accurate and less variable than with inbuilt spirometry. Differences between measurement methods were most significant in the smallest patients. We therefore recommend near-patient spirometry, especially for neonatal and paediatric patients. © 2018 The Association of Anaesthetists of Great Britain and Ireland.

  18. Gefinex 400S (Sampo) EM-Soundings at Olkiluoto 2007

    International Nuclear Information System (INIS)

    Jokinen, T.; Lehtimaeki, J.

    2007-09-01

    In the beginning of June 2007 Geological Survey of Finland carried out electromagnetic frequency soundings with Gefinex 400S equipment (Sampo) at Onkalo situated in Olkiluoto nuclear power plant area. The same soundings sites were the first time measured and marked in 2004 and repeated after it yearly. The aim of the measurements is to monitor the changes of groundwater conditions by the changes of the electric conductivity of the earth at ONKALO and repository area. The measurements form two 1400 m long broadside profiles, which have 200 m mutual distance and 200 m station separation. The profiles have been measured using 200, 500, and 800 m coil separations. The total number of the soundings stations is 48. In 2007 at 8 sounding stations the transmitter and/or receiver sites were changed and the line L11.400 was substituted by line L11.500. Some changes helped but anyway there were 6 stations that could not be measured because of the strong electromagnetic noise. The numerous power lines and the cables of the area generate local 3-D effects on the sounding curves, but the repeatability of the results is good. However, most suitable for monitoring purposes are the sites without strong 3-D effects. Comparison of results 2004-2007 shows small differences at some sounding sites. (orig.)

  19. The value of serial FDG PET on therapeutic evaluation and relapse monitoring of lung cancer

    International Nuclear Information System (INIS)

    Zhu Zhaohui; Cheng Wuying; Cui Ruixue; Chen Xin; Hao Li; Dang Yonghong; Zhe Fu; Wang Bocheng

    2004-01-01

    Purpose: A retrospective study was designed to investigate the value of serial FDG PET on therapeutic evaluation and relapse monitoring of lung cancer, and the influence factors to the evaluation and follow-up were also analyzed. Methods: Nineteen patients with confirmed lung cancer were included in the study, and they accepted a total of 87 FDG PET scans, with 3 to 12 times for each patient. The follow-up intervals of FDG PET varied from 14 days to 32 months, and 51 of 68 intervals were within 6 months with a mean of 3.3 months. The PET images of serial studies were analyzed with both visual and semi-quantitative Methods, and they were compared with other imaging techniques (CT, MRI and/or bone scan) and clinical follow-ups. Results: By providing metabolic information, FDG PET detected tumors with high contrast to normal tissue, and the serial examinations helped 9 patients in detecting and evaluating lesions in areas with complicated anatomic structures, such as lung hilus, mediastinum, supraclavicular and abdomen. PET also showed more accuracy and sensitivity than bone scan, CT or MRI in evaluation of bone metastases in two cases. Serial FDG PET was also helpful to the cases in complicated conditions with necrosis, fibrosis or changes of anatomic structures after multiple therapies. In two cases, the follow-up studies confirmed the metastases in the incision wound, which had increasing uptake while it decreased in the repairing wound tissue. By analyzing metabolism of the lesions, PET also showed changes in 3 cases, while they were unconcluded by CT and/or MRI. In some circumstances, benign uptake of FDG influenced the evaluation and monitoring. Inflammation after radiotherapy showed high uptake in 7 cases, and influenced the evaluation of therapy in the serial examinations. Recent use of granulocyte clone stimulation factor (G-CSF) caused diffuse high uptake in bone marrow, and it covered the bone metastases in one case. And in other two cases, diffuse high

  20. Seismic and Biological Sources of Ambient Ocean Sound

    Science.gov (United States)

    Freeman, Simon Eric

    Sound is the most efficient radiation in the ocean. Sounds of seismic and biological origin contain information regarding the underlying processes that created them. A single hydrophone records summary time-frequency information from the volume within acoustic range. Beamforming using a hydrophone array additionally produces azimuthal estimates of sound sources. A two-dimensional array and acoustic focusing produce an unambiguous two-dimensional `image' of sources. This dissertation describes the application of these techniques in three cases. The first utilizes hydrophone arrays to investigate T-phases (water-borne seismic waves) in the Philippine Sea. Ninety T-phases were recorded over a 12-day period, implying a greater number of seismic events occur than are detected by terrestrial seismic monitoring in the region. Observation of an azimuthally migrating T-phase suggests that reverberation of such sounds from bathymetric features can occur over megameter scales. In the second case, single hydrophone recordings from coral reefs in the Line Islands archipelago reveal that local ambient reef sound is spectrally similar to sounds produced by small, hard-shelled benthic invertebrates in captivity. Time-lapse photography of the reef reveals an increase in benthic invertebrate activity at sundown, consistent with an increase in sound level. The dominant acoustic phenomenon on these reefs may thus originate from the interaction between a large number of small invertebrates and the substrate. Such sounds could be used to take census of hard-shelled benthic invertebrates that are otherwise extremely difficult to survey. A two-dimensional `map' of sound production over a coral reef in the Hawaiian Islands was obtained using two-dimensional hydrophone array in the third case. Heterogeneously distributed bio-acoustic sources were generally co-located with rocky reef areas. Acoustically dominant snapping shrimp were largely restricted to one location within the area surveyed

  1. Sound segregation via embedded repetition is robust to inattention.

    Science.gov (United States)

    Masutomi, Keiko; Barascud, Nicolas; Kashino, Makio; McDermott, Josh H; Chait, Maria

    2016-03-01

    The segregation of sound sources from the mixture of sounds that enters the ear is a core capacity of human hearing, but the extent to which this process is dependent on attention remains unclear. This study investigated the effect of attention on the ability to segregate sounds via repetition. We utilized a dual task design in which stimuli to be segregated were presented along with stimuli for a "decoy" task that required continuous monitoring. The task to assess segregation presented a target sound 10 times in a row, each time concurrent with a different distractor sound. McDermott, Wrobleski, and Oxenham (2011) demonstrated that repetition causes the target sound to be segregated from the distractors. Segregation was queried by asking listeners whether a subsequent probe sound was identical to the target. A control task presented similar stimuli but probed discrimination without engaging segregation processes. We present results from 3 different decoy tasks: a visual multiple object tracking task, a rapid serial visual presentation (RSVP) digit encoding task, and a demanding auditory monitoring task. Load was manipulated by using high- and low-demand versions of each decoy task. The data provide converging evidence of a small effect of attention that is nonspecific, in that it affected the segregation and control tasks to a similar extent. In all cases, segregation performance remained high despite the presence of a concurrent, objectively demanding decoy task. The results suggest that repetition-based segregation is robust to inattention. (c) 2016 APA, all rights reserved).

  2. [Educational usefulness of lung auscultation training with an auscultation simulator].

    Science.gov (United States)

    Arimura, Yasuji; Komatsu, Hiroyuki; Yanagi, Shigehisa; Matsumoto, Nobuhiro; Okayama, Akihiko; Hayashi, Katsuhiro; Nakazato, Masamitsu

    2011-06-01

    We examined the educational usefulness of lung auscultation training with an auscultation simulator "Mr. Lung". Auscultation training was conducted for fifth-year students of the Medical Department of the University of Miyazaki, and consisted of a lecture by a pulmonologist (Board Certified Member of the Japanese Respiratory Society) and skill training using Mr. Lung for a total of 90 min. We compared the percentages of students who correctly identified 4 adventitious sounds before and after training. We also investigated the responses to a self-report questionnaire on self-evaluation after training, auscultation experiences before training, and opinions regarding medical education with the simulator. The subjects' correct answer rate before training was 40% or less and that for the correct identification of rhonchi was the lowest (5%). The correct answer rate, which was not influenced by previous experience of auscultation, significantly increased after training (80% or more). In the self-report questionnaire, about 90% of the students answered that the ability to identify lung sounds by auscultation was necessary for all doctors and that the simulator was effective for acquiring this skill. The auscultation simulator may be useful for medical students not only to enhance auscultatory skills but also to realize the importance of auscultation in clinical examination.

  3. Chaotic dynamics of respiratory sounds

    International Nuclear Information System (INIS)

    Ahlstrom, C.; Johansson, A.; Hult, P.; Ask, P.

    2006-01-01

    There is a growing interest in nonlinear analysis of respiratory sounds (RS), but little has been done to justify the use of nonlinear tools on such data. The aim of this paper is to investigate the stationarity, linearity and chaotic dynamics of recorded RS. Two independent data sets from 8 + 8 healthy subjects were recorded and investigated. The first set consisted of lung sounds (LS) recorded with an electronic stethoscope and the other of tracheal sounds (TS) recorded with a contact accelerometer. Recurrence plot analysis revealed that both LS and TS are quasistationary, with the parts corresponding to inspiratory and expiratory flow plateaus being stationary. Surrogate data tests could not provide statistically sufficient evidence regarding the nonlinearity of the data. The null hypothesis could not be rejected in 4 out of 32 LS cases and in 15 out of 32 TS cases. However, the Lyapunov spectra, the correlation dimension (D 2 ) and the Kaplan-Yorke dimension (D KY ) all indicate chaotic behavior. The Lyapunov analysis showed that the sum of the exponents was negative in all cases and that the largest exponent was found to be positive. The results are partly ambiguous, but provide some evidence of chaotic dynamics of RS, both concerning LS and TS. The results motivate continuous use of nonlinear tools for analysing RS data

  4. Chaotic dynamics of respiratory sounds

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstrom, C. [Department of Biomedical Engineering, Linkoepings Universitet, IMT/LIU, Universitetssjukhuset, S-58185 Linkoeping (Sweden) and Biomedical Engineering, Orebro University Hospital, S-70185 Orebro (Sweden)]. E-mail: christer@imt.liu.se; Johansson, A. [Department of Biomedical Engineering, Linkoepings Universitet, IMT/LIU, Universitetssjukhuset, S-58185 Linkoeping (Sweden); Hult, P. [Department of Biomedical Engineering, Linkoepings Universitet, IMT/LIU, Universitetssjukhuset, S-58185 Linkoeping (Sweden); Biomedical Engineering, Orebro University Hospital, S-70185 Orebro (Sweden); Ask, P. [Department of Biomedical Engineering, Linkoepings Universitet, IMT/LIU, Universitetssjukhuset, S-58185 Linkoeping (Sweden); Biomedical Engineering, Orebro University Hospital, S-70185 Orebro (Sweden)

    2006-09-15

    There is a growing interest in nonlinear analysis of respiratory sounds (RS), but little has been done to justify the use of nonlinear tools on such data. The aim of this paper is to investigate the stationarity, linearity and chaotic dynamics of recorded RS. Two independent data sets from 8 + 8 healthy subjects were recorded and investigated. The first set consisted of lung sounds (LS) recorded with an electronic stethoscope and the other of tracheal sounds (TS) recorded with a contact accelerometer. Recurrence plot analysis revealed that both LS and TS are quasistationary, with the parts corresponding to inspiratory and expiratory flow plateaus being stationary. Surrogate data tests could not provide statistically sufficient evidence regarding the nonlinearity of the data. The null hypothesis could not be rejected in 4 out of 32 LS cases and in 15 out of 32 TS cases. However, the Lyapunov spectra, the correlation dimension (D {sub 2}) and the Kaplan-Yorke dimension (D {sub KY}) all indicate chaotic behavior. The Lyapunov analysis showed that the sum of the exponents was negative in all cases and that the largest exponent was found to be positive. The results are partly ambiguous, but provide some evidence of chaotic dynamics of RS, both concerning LS and TS. The results motivate continuous use of nonlinear tools for analysing RS data.

  5. Foley Sounds vs Real Sounds

    DEFF Research Database (Denmark)

    Trento, Stefano; Götzen, Amalia De

    2011-01-01

    This paper is an initial attempt to study the world of sound effects for motion pictures, also known as Foley sounds. Throughout several audio and audio-video tests we have compared both Foley and real sounds originated by an identical action. The main purpose was to evaluate if sound effects...

  6. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  7. 78 FR 13869 - Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy...

    Science.gov (United States)

    2013-03-01

    ...-123-LNG; 12-128-NG; 12-148-NG; 12- 158-NG] Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; CE FLNG, LLC; Consolidated...-NG Puget Sound Energy, Inc Order granting long- term authority to import/export natural gas from/to...

  8. The value of 99Tcm-HSA in monitoring acute lung injury induced by lipopolysaccharide in rats

    International Nuclear Information System (INIS)

    Fu Zhanli; Zhang Chunli; Wang Rongfu; Zhang Shengsuo; Xue Yun

    2005-01-01

    To evaluate the value of 99 Tc m labeled human serum albumin ( 99 Tc m -HSA) in monitoring acute lung injury (ALI) induced by lipopolysaccharide (LPS) in rats, twenty adult Wistar rats are given 99 Tc m -HSA intravenously, and are randomly divided into four groups 30 min later. The control and LPS group are given intravenous injection of 0.9% saline and LPS 8 mg/kg respectively. The ketamine and aminoguanidine group are given intraperitoneal injection of ketamine 4 mg/kg and aminoguanidine 20 mg/kg respectively just 30 min after administration of LPS 8 mg/kg. All of the four group rats are killed by blood letting at 3 h post-injection of 99 Tc m -HSA. Pulmonary permeability index (PPI) and the ratio of lung wet weight and dry weight (W/D) is calculated. The results of PPI and W/D in control and LPS group are 95.58 ± 11.32 and 5.38 ± 0.24, 6.61 ± 0.18 and 4.19 ± 0.11, respectively. The PPI and W/D in LPS group are much higher than that in the control group (P 0.05). So 99 tc m -HSA is an effective tracer in monitoring ALI induced by LPS in rats. (authors)

  9. Relationship between radiation dose and lung function in patients with lung cancer receiving radiotherapy

    International Nuclear Information System (INIS)

    Harsaker, V.; Dale, E.; Bruland, O.S.; Olsen, D.R.

    2003-01-01

    In patients with inoperable non-small cell lung cancer (NSCLC), radical radiotherapy is the treatment of choice. The dose is limited by consequential pneumonitis and lung fibrosis. Hence, a better understanding of the relationship between the dose-volume distributions and normal tissue side effects is needed. CT is a non-invasive method to monitor the development of fibrosis and pneumonitis, and spirometry is an established tool to measure lung function. NSCLC patients were included in a multicenter trial and treated with megavoltage conformal radiotherapy. In a subgroup comprising 16 patients, a total dose of 59-63 Gy with 1.8-1.9 Gy per fraction was given. Dose-volume histograms were calculated and corrected according to the linear-quadratic formula using alpha/beta=3 Gy. The patients underwent repetitive CT examinations (mean follow-up, 133 days) following radiotherapy, and pre and post treatment spirometry (mean follow-up, 240 days). A significant correlation was demonstrated between local lung dose and changes in CT numbers >30 days after treatment (p 40 Gy Gy there was a sudden increase in CT numbers at 70-90 days. Somewhat unexpectedly, the highest mean lung doses were found in patients with the least reductions in lung function (peak expiratory flow; p<0.001). The correlation between CT numbers, radiation dose and time after treatment show that CT may be used to monitor development of lung fibrosis/pneumonitis after radiotherapy for lung cancer. Paradoxically, the patients with the highest mean lung doses experienced the minimum deterioration of lung function. This may be explained by reduction in the volume of existing tumour masses obstructing the airways, leading to relief of symptoms. This finding stresses the role of radiotherapy for lung cancer, especially where the treatment aim is palliative

  10. Postrelease monitoring of radio-instrumented sea otters in Prince William Sound

    Science.gov (United States)

    Monnett, C.; Rotterman, L.M.; Stack, C.; Monson, Daniel H.; Bayha, Keith; Kormendy, Jennifer

    1990-01-01

    Sea otters (Enhydra lutris) that were captured in western Prince William Sound (PWS) or the Gulf of Alaska, treated, and held in captivity at the temporary rehabilitation centers established in response to the T/V Exxon Valdez oil spill were instrumented with radio transmitters, released into eastern PWS, and monitored by radiotelemetry. We undertook the present study to gain information for guiding the release of the remaining captive otters and evaluating the efficacy of sea otter rehabilitation after exposure to crude oil. Radio transmitters were attached to the flippers of seven sea otters released in May 1989 and monitored for periods of a few hours to more than 60 days. However, little was learned about the fate of these animals because the radio transmitters used proved unreliable. Forty-five additional sea otters from the rehabilitation centers were implanted with radio transmitters, released into northeastern PWS and monitored for 8 months. During the first 20 days after the first release of these implanted otters (n = 21), they were more mobile than wild-caught and released sea otters studied in PWS, from 1984 through 1990. All were alive and vigorous at the end of the 20-day period. Tracking of all 45 implanted sea otters during the 8-month period showed that the otters remained highly mobile. Many (46.6%) crossed into western PWS. However, by the end of the 8 months, 12 of the instrumented otters were dead and 9 were missing. One radio failed. These mortality and missing rates are much higher than those normally observed for adult sea otters in PWS. The death rate was highest in winter. These data suggest that, despite the tremendous amount of money and energy directed toward the treatment and care of these animals, the sea otters released from the centers were not completely rehabilitated, that is, not returned to a normal state. We recommend that future policies focus on preventing otters from becoming oiled, rather than attempting to treat them

  11. Diversity of fish sound types in the Pearl River Estuary, China

    Directory of Open Access Journals (Sweden)

    Zhi-Tao Wang

    2017-10-01

    Full Text Available Background Repetitive species-specific sound enables the identification of the presence and behavior of soniferous species by acoustic means. Passive acoustic monitoring has been widely applied to monitor the spatial and temporal occurrence and behavior of calling species. Methods Underwater biological sounds in the Pearl River Estuary, China, were collected using passive acoustic monitoring, with special attention paid to fish sounds. A total of 1,408 suspected fish calls comprising 18,942 pulses were qualitatively analyzed using a customized acoustic analysis routine. Results We identified a diversity of 66 types of fish sounds. In addition to single pulse, the sounds tended to have a pulse train structure. The pulses were characterized by an approximate 8 ms duration, with a peak frequency from 500 to 2,600 Hz and a majority of the energy below 4,000 Hz. The median inter-pulsepeak interval (IPPI of most call types was 9 or 10 ms. Most call types with median IPPIs of 9 ms and 10 ms were observed at times that were exclusive from each other, suggesting that they might be produced by different species. According to the literature, the two section signal types of 1 + 1 and 1 + N10 might belong to big-snout croaker (Johnius macrorhynus, and 1 + N19 might be produced by Belanger’s croaker (J. belangerii. Discussion Categorization of the baseline ambient biological sound is an important first step in mapping the spatial and temporal patterns of soniferous fishes. The next step is the identification of the species producing each sound. The distribution pattern of soniferous fishes will be helpful for the protection and management of local fishery resources and in marine environmental impact assessment. Since the local vulnerable Indo-Pacific humpback dolphin (Sousa chinensis mainly preys on soniferous fishes, the fine-scale distribution pattern of soniferous fishes can aid in the conservation of this species. Additionally, prey and predator

  12. Sound Exposure During Outdoor Music Festivals

    Science.gov (United States)

    Tronstad, Tron V.; Gelderblom, Femke B.

    2016-01-01

    Most countries have guidelines to regulate sound exposure at concerts and music festivals. These guidelines limit the allowed sound pressure levels and the concert/festival's duration. In Norway, where there is such a guideline, it is up to the local authorities to impose the regulations. The need to prevent hearing-loss among festival participants is self-explanatory, but knowledge of the actual dose received by visitors is extremely scarce. This study looks at two Norwegian music festivals where only one was regulated by the Norwegian guideline for concert and music festivals. At each festival the sound exposure of four participants was monitored with noise dose meters. This study compared the exposures experienced at the two festivals, and tested them against the Norwegian guideline and the World Health Organization's recommendations. Sound levels during the concerts were higher at the festival not regulated by any guideline, and levels there exceeded both the national and the Worlds Health Organization's recommendations. The results also show that front-of-house measurements reliably predict participant exposure. PMID:27569410

  13. Sound exposure during outdoor music festivals

    Directory of Open Access Journals (Sweden)

    Tron V Tronstad

    2016-01-01

    Full Text Available Most countries have guidelines to regulate sound exposure at concerts and music festivals. These guidelines limit the allowed sound pressure levels and the concert/festival’s duration. In Norway, where there is such a guideline, it is up to the local authorities to impose the regulations. The need to prevent hearing-loss among festival participants is self-explanatory, but knowledge of the actual dose received by visitors is extremely scarce. This study looks at two Norwegian music festivals where only one was regulated by the Norwegian guideline for concert and music festivals. At each festival the sound exposure of four participants was monitored with noise dose meters. This study compared the exposures experienced at the two festivals, and tested them against the Norwegian guideline and the World Health Organization’s recommendations. Sound levels during the concerts were higher at the festival not regulated by any guideline, and levels there exceeded both the national and the Worlds Health Organization’s recommendations. The results also show that front-of-house measurements reliably predict participant exposure.

  14. Second sound scattering in superfluid helium

    International Nuclear Information System (INIS)

    Rosgen, T.

    1985-01-01

    Focusing cavities are used to study the scattering of second sound in liquid helium II. The special geometries reduce wall interference effects and allow measurements in very small test volumes. In a first experiment, a double elliptical cavity is used to focus a second sound wave onto a small wire target. A thin film bolometer measures the side scattered wave component. The agreement with a theoretical estimate is reasonable, although some problems arise from the small measurement volume and associated alignment requirements. A second cavity is based on confocal parabolas, thus enabling the use of large planar sensors. A cylindrical heater produces again a focused second sound wave. Three sensors monitor the transmitted wave component as well as the side scatter in two different directions. The side looking sensors have very high sensitivities due to their large size and resistance. Specially developed cryogenic amplifers are used to match them to the signal cables. In one case, a second auxiliary heater is used to set up a strong counterflow in the focal region. The second sound wave then scatters from the induced fluid disturbances

  15. Halifax Sound Range Trials (DE0301, EK500)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Radiated sound measurements of vessels are important for monitoring the noise characteristics of fishing and research vessels. A vessel's radiated noise can have...

  16. A noise reduction technique based on nonlinear kernel function for heart sound analysis.

    Science.gov (United States)

    Mondal, Ashok; Saxena, Ishan; Tang, Hong; Banerjee, Poulami

    2017-02-13

    The main difficulty encountered in interpretation of cardiac sound is interference of noise. The contaminated noise obscures the relevant information which are useful for recognition of heart diseases. The unwanted signals are produced mainly by lungs and surrounding environment. In this paper, a novel heart sound de-noising technique has been introduced based on a combined framework of wavelet packet transform (WPT) and singular value decomposition (SVD). The most informative node of wavelet tree is selected on the criteria of mutual information measurement. Next, the coefficient corresponding to the selected node is processed by SVD technique to suppress noisy component from heart sound signal. To justify the efficacy of the proposed technique, several experiments have been conducted with heart sound dataset, including normal and pathological cases at different signal to noise ratios. The significance of the method is validated by statistical analysis of the results. The biological information preserved in de-noised heart sound (HS) signal is evaluated by k-means clustering algorithm and Fit Factor calculation. The overall results show that proposed method is superior than the baseline methods.

  17. The Influence of Neonatal Intensive Care Unit Design on Sound Level

    Directory of Open Access Journals (Sweden)

    Hsin-Li Chen

    2009-12-01

    Conclusion: The sound level measured in the enclosed space was quieter than in the open space. The design of bed space should be taken into consideration when building a new NICU. Besides the design of NICU architecture, continuous monitoring of sound level in the NICU is important to maintain a quiet environment.

  18. Passive acoustic monitoring of the temporal variability of odontocete tonal sounds from a long-term marine observatory.

    Directory of Open Access Journals (Sweden)

    Tzu-Hao Lin

    Full Text Available The developments of marine observatories and automatic sound detection algorithms have facilitated the long-term monitoring of multiple species of odontocetes. Although classification remains difficult, information on tonal sound in odontocetes (i.e., toothed whales, including dolphins and porpoises can provide insights into the species composition and group behavior of these species. However, the approach to measure whistle contour parameters for detecting the variability of odontocete vocal behavior may be biased when the signal-to-noise ratio is low. Thus, methods for analyzing the whistle usage of an entire group are necessary. In this study, a local-max detector was used to detect burst pulses and representative frequencies of whistles within 4.5-48 kHz. Whistle contours were extracted and classified using an unsupervised method. Whistle characteristics and usage pattern were quantified based on the distribution of representative frequencies and the composition of whistle repertoires. Based on the one year recordings collected from the Marine Cable Hosted Observatory off northeastern Taiwan, odontocete burst pulses and whistles were primarily detected during the nighttime, especially after sunset. Whistle usage during the nighttime was more complex, and whistles with higher frequency were mainly detected during summer and fall. According to the multivariate analysis, the diurnal variation of whistle usage was primarily related to the change of mode frequency, diversity of representative frequency, and sequence complexity. The seasonal variation of whistle usage involved the previous three parameters, in addition to the diversity of whistle clusters. Our results indicated that the species and behavioral composition of the local odontocete community may vary among seasonal and diurnal cycles. The current monitoring platform facilitates the evaluation of whistle usage based on group behavior and provides feature vectors for species and

  19. Towards lung EIT image segmentation: automatic classification of lung tissue state from analysis of EIT monitored recruitment manoeuvres

    International Nuclear Information System (INIS)

    Grychtol, Bartłomiej; Wolf, Gerhard K; Arnold, John H; Adler, Andy

    2010-01-01

    There is emerging evidence that the ventilation strategy used in acute lung injury (ALI) makes a significant difference in outcome and that an inappropriate ventilation strategy may produce ventilator-associated lung injury. Most harmful during mechanical ventilation are lung overdistension and lung collapse or atelectasis. Electrical impedance tomography (EIT) as a non-invasive imaging technology may be helpful to identify lung areas at risk. Currently, no automated method is routinely available to identify lung areas that are overdistended, collapsed or ventilated appropriately. We propose a fuzzy logic-based algorithm to analyse EIT images obtained during stepwise changes of mean airway pressures during mechanical ventilation. The algorithm is tested on data from two published studies of stepwise inflation–deflation manoeuvres in an animal model of ALI using conventional and high-frequency oscillatory ventilation. The timing of lung opening and collapsing on segmented images obtained using the algorithm during an inflation–deflation manoeuvre is in agreement with well-known effects of surfactant administration and changes in shunt fraction. While the performance of the algorithm has not been verified against a gold standard, we feel that it presents an important first step in tackling this challenging and important problem

  20. Towards lung EIT image segmentation: automatic classification of lung tissue state from analysis of EIT monitored recruitment manoeuvres.

    Science.gov (United States)

    Grychtol, Bartłomiej; Wolf, Gerhard K; Adler, Andy; Arnold, John H

    2010-08-01

    There is emerging evidence that the ventilation strategy used in acute lung injury (ALI) makes a significant difference in outcome and that an inappropriate ventilation strategy may produce ventilator-associated lung injury. Most harmful during mechanical ventilation are lung overdistension and lung collapse or atelectasis. Electrical impedance tomography (EIT) as a non-invasive imaging technology may be helpful to identify lung areas at risk. Currently, no automated method is routinely available to identify lung areas that are overdistended, collapsed or ventilated appropriately. We propose a fuzzy logic-based algorithm to analyse EIT images obtained during stepwise changes of mean airway pressures during mechanical ventilation. The algorithm is tested on data from two published studies of stepwise inflation-deflation manoeuvres in an animal model of ALI using conventional and high-frequency oscillatory ventilation. The timing of lung opening and collapsing on segmented images obtained using the algorithm during an inflation-deflation manoeuvre is in agreement with well-known effects of surfactant administration and changes in shunt fraction. While the performance of the algorithm has not been verified against a gold standard, we feel that it presents an important first step in tackling this challenging and important problem.

  1. Swallowing sound detection using hidden markov modeling of recurrence plot features

    International Nuclear Information System (INIS)

    Aboofazeli, Mohammad; Moussavi, Zahra

    2009-01-01

    Automated detection of swallowing sounds in swallowing and breath sound recordings is of importance for monitoring purposes in which the recording durations are long. This paper presents a novel method for swallowing sound detection using hidden Markov modeling of recurrence plot features. Tracheal sound recordings of 15 healthy and nine dysphagic subjects were studied. The multidimensional state space trajectory of each signal was reconstructed using the Taken method of delays. The sequences of three recurrence plot features of the reconstructed trajectories (which have shown discriminating capability between swallowing and breath sounds) were modeled by three hidden Markov models. The Viterbi algorithm was used for swallowing sound detection. The results were validated manually by inspection of the simultaneously recorded airflow signal and spectrogram of the sounds, and also by auditory means. The experimental results suggested that the performance of the proposed method using hidden Markov modeling of recurrence plot features was superior to the previous swallowing sound detection methods.

  2. Swallowing sound detection using hidden markov modeling of recurrence plot features

    Energy Technology Data Exchange (ETDEWEB)

    Aboofazeli, Mohammad [Faculty of Engineering, Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, Manitoba, R3T 5V6 (Canada)], E-mail: umaboofa@cc.umanitoba.ca; Moussavi, Zahra [Faculty of Engineering, Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, Manitoba, R3T 5V6 (Canada)], E-mail: mousavi@ee.umanitoba.ca

    2009-01-30

    Automated detection of swallowing sounds in swallowing and breath sound recordings is of importance for monitoring purposes in which the recording durations are long. This paper presents a novel method for swallowing sound detection using hidden Markov modeling of recurrence plot features. Tracheal sound recordings of 15 healthy and nine dysphagic subjects were studied. The multidimensional state space trajectory of each signal was reconstructed using the Taken method of delays. The sequences of three recurrence plot features of the reconstructed trajectories (which have shown discriminating capability between swallowing and breath sounds) were modeled by three hidden Markov models. The Viterbi algorithm was used for swallowing sound detection. The results were validated manually by inspection of the simultaneously recorded airflow signal and spectrogram of the sounds, and also by auditory means. The experimental results suggested that the performance of the proposed method using hidden Markov modeling of recurrence plot features was superior to the previous swallowing sound detection methods.

  3. Monitoring of aquifer pump tests with Magnetic Resonance Sounding (MRS)

    DEFF Research Database (Denmark)

    Herckenrath, Daan; Auken, Esben; Bauer-Gottwein, Peter

    2009-01-01

    Magnetic Resonance Sounding (MRS) can provide valuable data to constrain and calibrate groundwater flow and transport models. With this non-invasive geophysical technique, field measurements of water content and hydraulic conductivities can be obtained. We developed a hydrogeophyiscal forward...

  4. MRI of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Kauczor, Hans-Ulrich (ed.) [University Clinic Heidelberg (Germany). Diagnostic and Interventional Radiology

    2009-07-01

    For a long time, only chest X-ray and CT were used to image lung structure, while nuclear medicine was employed to assess lung function. During the past decade significant developments have been achieved in the field of magnetic resonance imaging (MRI), enabling MRI to enter the clinical arena of chest imaging. Standard protocols can now be implemented on up-to-date scanners, allowing MRI to be used as a first-line imaging modality for various lung diseases, including cystic fibrosis, pulmonary hypertension and even lung cancer. The diagnostic benefits stem from the ability of MRI to visualize changes in lung structure while simultaneously imaging different aspects of lung function, such as perfusion, respiratory motion, ventilation and gas exchange. On this basis, novel quantitative surrogates for lung function can be obtained. This book provides a comprehensive overview of how to use MRI for imaging of lung disease. Special emphasis is placed on benign diseases requiring regular monitoring, given that it is patients with these diseases who derive the greatest benefit from the avoidance of ionizing radiation. (orig.)

  5. Automatic adventitious respiratory sound analysis: A systematic review.

    Directory of Open Access Journals (Sweden)

    Renard Xaviero Adhi Pramono

    Full Text Available Automatic detection or classification of adventitious sounds is useful to assist physicians in diagnosing or monitoring diseases such as asthma, Chronic Obstructive Pulmonary Disease (COPD, and pneumonia. While computerised respiratory sound analysis, specifically for the detection or classification of adventitious sounds, has recently been the focus of an increasing number of studies, a standardised approach and comparison has not been well established.To provide a review of existing algorithms for the detection or classification of adventitious respiratory sounds. This systematic review provides a complete summary of methods used in the literature to give a baseline for future works.A systematic review of English articles published between 1938 and 2016, searched using the Scopus (1938-2016 and IEEExplore (1984-2016 databases. Additional articles were further obtained by references listed in the articles found. Search terms included adventitious sound detection, adventitious sound classification, abnormal respiratory sound detection, abnormal respiratory sound classification, wheeze detection, wheeze classification, crackle detection, crackle classification, rhonchi detection, rhonchi classification, stridor detection, stridor classification, pleural rub detection, pleural rub classification, squawk detection, and squawk classification.Only articles were included that focused on adventitious sound detection or classification, based on respiratory sounds, with performance reported and sufficient information provided to be approximately repeated.Investigators extracted data about the adventitious sound type analysed, approach and level of analysis, instrumentation or data source, location of sensor, amount of data obtained, data management, features, methods, and performance achieved.A total of 77 reports from the literature were included in this review. 55 (71.43% of the studies focused on wheeze, 40 (51.95% on crackle, 9 (11.69% on stridor, 9

  6. Automatic adventitious respiratory sound analysis: A systematic review.

    Science.gov (United States)

    Pramono, Renard Xaviero Adhi; Bowyer, Stuart; Rodriguez-Villegas, Esther

    2017-01-01

    Automatic detection or classification of adventitious sounds is useful to assist physicians in diagnosing or monitoring diseases such as asthma, Chronic Obstructive Pulmonary Disease (COPD), and pneumonia. While computerised respiratory sound analysis, specifically for the detection or classification of adventitious sounds, has recently been the focus of an increasing number of studies, a standardised approach and comparison has not been well established. To provide a review of existing algorithms for the detection or classification of adventitious respiratory sounds. This systematic review provides a complete summary of methods used in the literature to give a baseline for future works. A systematic review of English articles published between 1938 and 2016, searched using the Scopus (1938-2016) and IEEExplore (1984-2016) databases. Additional articles were further obtained by references listed in the articles found. Search terms included adventitious sound detection, adventitious sound classification, abnormal respiratory sound detection, abnormal respiratory sound classification, wheeze detection, wheeze classification, crackle detection, crackle classification, rhonchi detection, rhonchi classification, stridor detection, stridor classification, pleural rub detection, pleural rub classification, squawk detection, and squawk classification. Only articles were included that focused on adventitious sound detection or classification, based on respiratory sounds, with performance reported and sufficient information provided to be approximately repeated. Investigators extracted data about the adventitious sound type analysed, approach and level of analysis, instrumentation or data source, location of sensor, amount of data obtained, data management, features, methods, and performance achieved. A total of 77 reports from the literature were included in this review. 55 (71.43%) of the studies focused on wheeze, 40 (51.95%) on crackle, 9 (11.69%) on stridor, 9 (11

  7. Performance of long-term CT monitoring in diagnosing bronchiolitis obliterans after lung transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Berstad, Audun E. [Department of Radiology, Rikshospitalet University Hospital, Sognsvannsveien 20, N-0027 Oslo (Norway)]. E-mail: a.e.berstad@medisin.uio.no; Aalokken, Trond Mogens [Department of Radiology, Rikshospitalet University Hospital, Sognsvannsveien 20, N-0027 Oslo (Norway); Kolbenstvedt, Alf [Department of Radiology, Rikshospitalet University Hospital, Sognsvannsveien 20, N-0027 Oslo (Norway); Bjortuft, Oystein [Department of Thoracic Medicine, Rikshospitalet University Hospital, Sognsvannsveien 20, N-0027 Oslo (Norway)

    2006-04-15

    Aim: The purpose of the study was to evaluate the ability of CT, including expiratory scans with minimum intensity projection in predicting the development of bronchiolitis obliterans syndrome after lung transplantation. Materials and methods: Forty consecutive patients, 29 bilateral and 11 single lung transplanted, were followed-up with regular scans for a median of 36 months. Air trapping was evaluated on expiratory scans constructed from two short spiral scans with minimum intensity projection-technique, one at the level of the carina and the other midway between the right diaphragm and the carina. Air trapping was scored on a 16-point scale. Bronchiolitis obliterans syndrome was diagnosed according to established clinical criteria and quantified spirometrically. Results: Bronchiolitis obliterans syndrome developed in 17 patients (43%) after a median of 12 months. Air trapping and bronchiectasis was seen before the diagnosis of bronchiolitis obliterans syndrome in only two and one patient, respectively. Interobserver agreement for air trapping score was good (kappa = 0.65). Air trapping scores performed significantly better than that achieved by chance alone in determining the presence of bronchiolitis obliterans syndrome (P = 0.0025). An air trapping score of 4 or more provided the best results with regard to sensitivity and specificity in diagnosing bronchiolitis obliterans syndrome. The sensitivity, specificity, positive and negative predictive values of an air trapping of 4 or more in the diagnosis of bronchiolitis obliterans syndrome were 77, 74, 68 and 81%, respectively. Conclusion: Expiratory CT scans with minimum intensity projection-reconstruction did not predict the development of bronchiolitis obliterans syndrome in most patients. The findings seriously limit the clinical usefulness of long-term CT monitoring for diagnosing bronchiolitis obliterans syndrome after lung transplantation.

  8. Sound

    CERN Document Server

    Robertson, William C

    2003-01-01

    Muddled about what makes music? Stuck on the study of harmonics? Dumbfounded by how sound gets around? Now you no longer have to struggle to teach concepts you really don t grasp yourself. Sound takes an intentionally light touch to help out all those adults science teachers, parents wanting to help with homework, home-schoolers seeking necessary scientific background to teach middle school physics with confidence. The book introduces sound waves and uses that model to explain sound-related occurrences. Starting with the basics of what causes sound and how it travels, you'll learn how musical instruments work, how sound waves add and subtract, how the human ear works, and even why you can sound like a Munchkin when you inhale helium. Sound is the fourth book in the award-winning Stop Faking It! Series, published by NSTA Press. Like the other popular volumes, it is written by irreverent educator Bill Robertson, who offers this Sound recommendation: One of the coolest activities is whacking a spinning metal rod...

  9. Sound solutions for habitat monitoring

    Science.gov (United States)

    Mary M. Rowland; Lowell H. Suring; Christina D. Vojta

    2015-01-01

    For agencies and organizations to effectively manage wildlife, knowledge about the status and trend of wildlife habitat is critical. Traditional wildlife monitoring, however, has focused on populations rather than habitat, because ultimately population status drives long-term species viability. Still, habitat loss has contributed to the decline of nearly all at-risk...

  10. Results of time-domain electromagnetic soundings in Miami-Dade and southern Broward Counties, Florida

    Science.gov (United States)

    Fitterman, David V.; Prinos, Scott T.

    2011-01-01

    Time-domain electromagnetic (TEM) soundings were made in Miami-Dade and southern Broward Counties to aid in mapping the landward extent of saltwater in the Biscayne aquifer. A total of 79 soundings were collected in settings ranging from urban to undeveloped land, with some of the former posing problems of land access and interference from anthropogenic features. TEM soundings combined with monitoring-well data were used to determine if the saltwater front had moved since the last time it was mapped, to provide additional spatial coverage where existing monitoring wells were insufficient, and to help interpret a previously collected helicopter electromagnetic (HEM) survey flown in the southernmost portion of the study area. TEM soundings were interpreted as layered resistivity-depth models. Using information from well logs and water-quality data, the resistivity of the freshwater saturated Biscayne aquifer is expected to be above 30 ohm-meters, and the saltwater-saturated aquifer will have resistivities of less than 10 ohm-meters allowing determination of water quality from the TEM interpretations. TEM models from 29 soundings were compared to electromagnetic induction logs collected in nearby monitoring wells. In general, the agreement of these results was very good, giving confidence in the use of the TEM data for mapping saltwater encroachment.

  11. Sound Is Sound: Film Sound Techniques and Infrasound Data Array Processing

    Science.gov (United States)

    Perttu, A. B.; Williams, R.; Taisne, B.; Tailpied, D.

    2017-12-01

    A multidisciplinary collaboration between earth scientists and a sound designer/composer was established to explore the possibilities of audification analysis of infrasound array data. Through the process of audification of the infrasound we began to experiment with techniques and processes borrowed from cinema to manipulate the noise content of the signal. The results of this posed the question: "Would the accuracy of infrasound data array processing be enhanced by employing these techniques?". So a new area of research was born from this collaboration and highlights the value of these interactions and the unintended paths that can occur from them. Using a reference event database, infrasound data were processed using these new techniques and the results were compared with existing techniques to asses if there was any improvement to detection capability for the array. With just under one thousand volcanoes, and a high probability of eruption, Southeast Asia offers a unique opportunity to develop and test techniques for regional monitoring of volcanoes with different technologies. While these volcanoes are monitored locally (e.g. seismometer, infrasound, geodetic and geochemistry networks) and remotely (e.g. satellite and infrasound), there are challenges and limitations to the current monitoring capability. Not only is there a high fraction of cloud cover in the region, making plume observation more difficult via satellite, there have been examples of local monitoring networks and telemetry being destroyed early in the eruptive sequence. The success of local infrasound studies to identify explosions at volcanoes, and calculate plume heights from these signals, has led to an interest in retrieving source parameters for the purpose of ash modeling with a regional network independent of cloud cover.

  12. Monitoring and assessment of ingestive chewing sounds for prediction of herbage intake rate in grazing cattle.

    Science.gov (United States)

    Galli, J R; Cangiano, C A; Pece, M A; Larripa, M J; Milone, D H; Utsumi, S A; Laca, E A

    2018-05-01

    Accurate measurement of herbage intake rate is critical to advance knowledge of the ecology of grazing ruminants. This experiment tested the integration of behavioral and acoustic measurements of chewing and biting to estimate herbage dry matter intake (DMI) in dairy cows offered micro-swards of contrasting plant structure. Micro-swards constructed with plastic pots were offered to three lactating Holstein cows (608±24.9 kg of BW) in individual grazing sessions (n=48). Treatments were a factorial combination of two forage species (alfalfa and fescue) and two plant heights (tall=25±3.8 cm and short=12±1.9 cm) and were offered on a gradient of increasing herbage mass (10 to 30 pots) and number of bites (~10 to 40 bites). During each grazing session, sounds of biting and chewing were recorded with a wireless microphone placed on the cows' foreheads and a digital video camera to allow synchronized audio and video recordings. Dry matter intake rate was higher in tall alfalfa than in the other three treatments (32±1.6 v. 19±1.2 g/min). A high proportion of jaw movements in every grazing session (23 to 36%) were compound jaw movements (chew-bites) that appeared to be a key component of chewing and biting efficiency and of the ability of cows to regulate intake rate. Dry matter intake was accurately predicted based on easily observable behavioral and acoustic variables. Chewing sound energy measured as energy flux density (EFD) was linearly related to DMI, with 74% of EFD variation explained by DMI. Total chewing EFD, number of chew-bites and plant height (tall v. short) were the most important predictors of DMI. The best model explained 91% of the variation in DMI with a coefficient of variation of 17%. Ingestive sounds integrate valuable information to remotely monitor feeding behavior and predict DMI in grazing cows.

  13. SU-E-T-31: Alternative VMAT Technique Reduces Total Monitor Units for Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Happersett, L; Mechalakos, J; Kuo, L; Zhang, P; Rimner, A [Memorial Sloan-Kettering Cancer Center, NY, NY (United States)

    2014-06-01

    Purpose: To investigate an alternative approach to VMAT optimization for hypofractionation lung treatment which increases average aperture opening and results in lower total Monitor Units (MU) without significantly sacrificing plan quality. Methods: Benchmark Volumetric Modulated Arc Therapy (bVMAT) plans were generated for 10 lung Stereotactic Body radiotherapy (SBRT) cases using Eclipse Version 11.0.42 (Varian Medical Systems) without a maximum MU constraint. Prescriptions ranged from 40 to 54Gy in 3 to 5 fractions. AAA dose calculation and PRO fluence based optimization was utilized. Two comparison VMAT plans were generated for each case, one that forced an initial “open” mlc aperture conformal to the tumor as a starting condition (oVMAT) with similar optimization parameters and arc geometries, and one that repeated the bVMAT optimization but added a maximum MU constraint (muVMAT). All plans used two arcs with lengths between 168 to 230 degrees. PTV D 95% and Dmean, lung V20 Gy, chest wall V30 Gy, average aperture opening and MU's were compared. Statistical significance was evaluated using Wilcoxon signed rank test. Results: Average PTV D(95), PTV mean and lung V20Gy over all plans was 99.2 ± 1.7%, 103.3 ± 0.6% and 7.8 ± 2.4% respectively. The average chest wall V30Gy was 61 ± 61 cc and ranged between 0 to 166 cc. There were no significant differences between the three techniques for the dosimetric quantities. MUs were reduced by 11 ±11% (p<0.01) and 25 ± 5% (p<0.01) and the average aperture size was increased by 13.7 ± 14% (p=0.02) and 35.8 ± 10% (p<0.01) with muVMAT and oVMAT, respectively, compared to bVMAT. Conclusion: oVMAT and muVMAT techniques were both able to increase average aperture size and reduce total MU compared to the benchmark VMAT plan, but the magnitude of the changes observed for oVMAT was larger.

  14. Nationwide quality improvement in lung cancer care

    DEFF Research Database (Denmark)

    Jakobsen, Erik Winther; Green, Anders; Oesterlind, Kell

    2013-01-01

    To improve prognosis and quality of lung cancer care the Danish Lung Cancer Group has developed a strategy consisting of national clinical guidelines and a clinical quality and research database. The first edition of our guidelines was published in 1998 and our national lung cancer registry...... was opened for registrations in 2000. This article describes methods and results obtained by multidisciplinary collaboration and illustrates how quality of lung cancer care can be improved by establishing and monitoring result and process indicators....

  15. Estimation of patient-specific imaging dose for real-time tumour monitoring in lung patients during respiratory-gated radiotherapy

    Science.gov (United States)

    Shiinoki, Takehiro; Onizuka, Ryota; Kawahara, Daisuke; Suzuki, Tatsuhiko; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Hanazawa, Hideki; Shibuya, Keiko

    2018-03-01

    Purpose: To quantify the patient-specific imaging dose for real-time tumour monitoring in the lung during respiratory-gated stereotactic body radiotherapy (SBRT) in clinical cases using SyncTraX. Methods and Materials: Ten patients who underwent respiratory-gated SBRT with SyncTraX were enrolled in this study. The imaging procedure for real-time tumour monitoring using SyncTraX was simulated using Monte Carlo. We evaluated the dosimetric effect of a real-time tumour monitoring in a critical organ at risk (OAR) and the planning target volume (PTV) over the course of treatment. The relationship between skin dose and gating efficiency was also investigated. Results: For all patients, the mean D50 to the PTV, ipsilateral lung, liver, heart, spinal cord and skin was 118.3 (21.5–175.9), 31.9 (9.5–75.4), 15.4 (1.1–31.6), 10.1 (1.3–18.1), 25.0 (1.6–101.8), and 3.6 (0.9–7.1) mGy, respectively. The mean D2 was 352.0 (26.5–935.8), 146.4 (27.3–226.7), 90.7 (3.6–255.0), 42.2 (4.8–82.7), 88.0 (15.4–248.5), and 273.5 (98.3–611.6) mGy, respectively. The D2 of the skin dose was found to increase as the gating efficiency decreased. Conclusions: The additional dose to the PTV was at most 1.9% of the prescribed dose over the course of treatment for real-time tumour monitoring. For OARs, we could confirm the high dose region, which may not be susceptible to radiation toxicity. However, to reduce the skin dose from SyncTraX, it is necessary to increase the gating efficiency.

  16. Treatment of the X and γ rays lung monitoring spectra obtained by using HP-Ge detectors in case of exposures to uranium

    International Nuclear Information System (INIS)

    Berard, P.; Pourret, O.; Aussel, J.P.; Rongier, E.

    1996-01-01

    A lung monitoring counting spectrum can be described as a random phenomenon. Channel-by-channel Poisson-type modelling was verified for cases of pure background. When carrying out spectral analysis for qualitative research, one must work with the sum of the detectors. The quantification must be calculated detector by detector. Statistical tests make it possible to certify that one or several peaks are really present in the organism. The calculations are currently made with automatic spectral analysis, peak search, specific area, statistics and probability of the real presence of analytic photo peak taking into account the morphological parameters of the worker. The results are analysed detector by detector, with and without the background of the room. Detection limits obtained in Pierrelatte in monitoring measurement conditions were assessed for variable tissues covering the range of subjects to be examined. For each subject, the calculations are made taking into account the equivalent tissue thicknesses derived from individual morphological parameters. This method makes it possible to quantify lung activities with a detection limit of 3.9 Bq ( 235 U; thirty minutes counting time; reference man parameters) and to monitor exposure to the different compounds of uranium. (author)

  17. INVASIVE SALMONELLOSIS PRESENTING AS A LUNG ABSCESS: A CASE REPORT.

    Science.gov (United States)

    Songkhla, Munjit Na; Chayakulkeeree, Methee

    2017-01-01

    Salmonella spp are an uncommon cause of lung abscess. A 59 year old man presented to our hospital with a 1 month history of cough and low grade fever progressing to high grade fever for 1 week. He had a past medical history significant for diabetes mellitus type 2 and focal segmental glomerulosclerosis for which he was receiving prednisolone, initially at 60 mg daily tapering to 20 mg daily. On presentation he was febrile and had decreased breath sounds and dullness to percussion over the right lower lung field. A chest X-ray showed a cavitary lesion with an air-fluid level in the right lung. Computed tomography of the lung revealed 2 cavitary lesions in the right upper and lower lungs. Sputum culture revealed Salmonella spp group B. He was treated successfully with ceftriaxone intravenously for 1 month followed by oral cefdinir. A chest X-ray at 1 month showed significant improvement; he was treated conservatively without surgical drainage. Salmonella can cause lung abscesses, especially in the immune suppressed.

  18. Acoustic phenomena observed in lung auscultation

    Science.gov (United States)

    Korenbaum, V. I.; Tagil'Tsev, A. A.; Kulakov, Yu. V.

    2003-05-01

    The results of studying respiratory noise at the chest wall by the method of acoustic intensimetry reveal the presence of frequency components with different signs of the real and imaginary parts of the cross spectrum obtained for the responses of the receivers of vibratory displacement and dynamic force. An acoustic model is proposed to explain this difference on the basis of the hypothesis that the contributions of both air-borne and structure-borne sound are significant in the transmission of respiratory noise to the chest wall. It is shown that, when considered as an acoustic channel for the basic respiratory noise, the respiratory system of an adult subject has two resonances: in the frequency bands within 110 150 and 215 350 Hz. For adults in normal condition, the air-borne component of the basic respiratory noise predominates in the region 100 300 Hz in the lower parts of lungs. At forced respiration of healthy adults, the sounds of vesicular respiration are generated by the turbulent air flow in the 11th-through 13th-generation bronchi, and the transmission of these sounds to the chest wall in normal condition is mainly through air and is determined by the resonance of the vibratory system formed by the elasticity of air in the respiratory ducts of lungs and by the surface mass density of the chest wall. It is demonstrated that the distance from the chest wall to the sources of structure-borne additional respiratory noise, namely, wheezing with frequencies above 300 Hz, can be estimated numerically from the ratio between the real and imaginary parts of the cross spectrum on the assumption that the source is of the quadrupole type.

  19. Reactor noise monitoring device

    International Nuclear Information System (INIS)

    Yamanaka, Hiroto.

    1990-01-01

    The present invention concerns a reactor noise monitoring device by detecting abnormal sounds in background noises. Vibration sounds detected by accelerometers are applied to a loose parts detector. The detector generates high alarm if there are sudden impact sounds in the background noises and applies output signals to an accumulation device. If there is slight impact sounds in the vicinity of any of the accelerometers, the accumulation device accumulates the abnormal sounds assumed to be generated from an identical site while synchronizing the waveforms for all of the channels. Then, the device outputs signals in which the background noises are cancelled, as detection signals. Therefore, S/N ratio can be improved and the abnormal sounds contained in the background noises can be detected, to thereby improve the accuracy for estimating the position where the abnormal sounds are generated. (I.S.)

  20. Automatic Bowel Motility Evaluation Technique for Noncontact Sound Recordings

    Directory of Open Access Journals (Sweden)

    Ryunosuke Sato

    2018-06-01

    Full Text Available Information on bowel motility can be obtained via magnetic resonance imaging (MRIs and X-ray imaging. However, these approaches require expensive medical instruments and are unsuitable for frequent monitoring. Bowel sounds (BS can be conveniently obtained using electronic stethoscopes and have recently been employed for the evaluation of bowel motility. More recently, our group proposed a novel method to evaluate bowel motility on the basis of BS acquired using a noncontact microphone. However, the method required manually detecting BS in the sound recordings, and manual segmentation is inconvenient and time consuming. To address this issue, herein, we propose a new method to automatically evaluate bowel motility for noncontact sound recordings. Using simulations for the sound recordings obtained from 20 human participants, we showed that the proposed method achieves an accuracy of approximately 90% in automatic bowel sound detection when acoustic feature power-normalized cepstral coefficients are used as inputs to artificial neural networks. Furthermore, we showed that bowel motility can be evaluated based on the three acoustic features in the time domain extracted by our method: BS per minute, signal-to-noise ratio, and sound-to-sound interval. The proposed method has the potential to contribute towards the development of noncontact evaluation methods for bowel motility.

  1. Sound algorithms

    OpenAIRE

    De Götzen , Amalia; Mion , Luca; Tache , Olivier

    2007-01-01

    International audience; We call sound algorithms the categories of algorithms that deal with digital sound signal. Sound algorithms appeared in the very infancy of computer. Sound algorithms present strong specificities that are the consequence of two dual considerations: the properties of the digital sound signal itself and its uses, and the properties of auditory perception.

  2. Detectability of T1a lung cancer on digital chest radiographs: an observer-performance comparison among 2-megapixel general-purpose, 2-megapixel medical-purpose, and 3-megapixel medical-purpose liquid-crystal display (LCD) monitors.

    Science.gov (United States)

    Yabuuchi, Hidetake; Matsuo, Yoshio; Kamitani, Takeshi; Jinnnouchi, Mikako; Yonezawa, Masato; Yamasaki, Yuzo; Nagao, Michinobu; Kawanami, Satoshi; Okamoto, Tatsuro; Sasaki, Masayuki; Honda, Hiroshi

    2015-08-01

    There has been no comparison of detectability of small lung cancer between general and medical LCD monitors or no comparison of detectability of small lung cancer between solid and part-solid nodules. To compare the detectabilities of T1a lung cancer on chest radiographs on three LCD monitor types: 2-megapixel (MP) for general purpose (General), 2-MP for medical purpose (Medical), and 3-MP-Medical. Radiographs from forty patients with T1aN0M0 primary lung cancer (27 solid nodules, 13 part-solid nodules) and 60 patients with no abnormalities on both chest X-ray and computed tomography (CT) were consecutively collected. Five readers assessed 100 cases for each monitor. The observations were analyzed using receiver operating characteristic (ROC) analysis. A jackknife method was used for statistical analysis. A P value of General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.86, 0.89, and 0.89, respectively; there were no significant differences among them. The average AUC for part-solid nodule detection using a 2-MP-General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.77, 0.86, and 0.89, respectively. There were significant differences between the 2-MP-General and 2-MP-Medical LCD monitors (P = 0.043) and between the 2-MP-General and 3-MP-Medical LCD monitors (P = 0.027). There was no significant difference between the 2-MP-Medical and 3-MP-Medical LCD monitors. The average AUC for solid nodule detection using a 2-MP-General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.90, 0.90, and 0.88, respectively; there were no significant differences among them. The mean AUC values for all and part-solid nodules of the low-experienced readers were significantly lower than those of the high-experienced readers with the 2 M-GP color LCD monitor (P general-purpose LCD monitor was significantly lower than those using medical-purpose LCD monitors. © The Foundation Acta Radiologica 2014.

  3. [Effects of lung protective ventilation strategy combined with lung recruitment maneuver on patients with severe burn complicated with acute respiratory distress syndrome].

    Science.gov (United States)

    Li, Xiaojian; Zhong, Xiaomin; Deng, Zhongyuan; Zhang Xuhui; Zhang, Zhi; Zhang, Tao; Tang, Wenbin; Chen, Bib; Liu, Changling; Cao, Wenjuan

    2014-08-01

    To investigate the effects of lung protective ventilation strategy combined with lung recruitment maneuver on ARDS complicating patients with severe burn. Clinical data of 15 severely burned patients with ARDS admitted to our burn ICU from September 2011 to September 2013 and conforming to the study criteria were analyzed. Right after the diagnosis of acute lung injury/ARDS, patients received mechanical ventilation with lung protective ventilation strategy. When the oxygenation index (OI) was below or equal to 200 mmHg (1 mmHg = 0. 133 kPa), lung recruitment maneuver was performed combining incremental positive end-expiratory pressure. When OI was above 200 mmHg, lung recruitment maneuver was stopped and ventilation with lung protective ventilation strategy was continued. When OI was above 300 mmHg, mechanical ventilation was stopped. Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, variables of blood gas analysis (pH, PaO2, and PaCO2) were obtained by blood gas analyzer, and the OI values were calculated; hemodynamic parameters including heart rate, mean arterial pressure (MAP), central venous pressure (CVP) of all patients and the cardiac output (CO), extravascular lung water index (EVLWI) of 4 patients who received pulse contour cardiac output (PiCCO) monitoring were monitored. Treatment measures and outcome of patients were recorded. Data were processed with analysis of variance of repeated measurement of a single group and LSD test. (1) Before combining lung recruitment maneuver, 24 h after combining lung recruitment maneuver, and at the end of combining lung recruitment maneuver, the levels of PaO2 and OI of patients were respectively (77 ± 8), (113 ± 5), (142 ± 6) mmHg, and (128 ± 12), (188 ± 8), (237 ± 10) mmHg. As a whole, levels of PaO2 and OI changed significantly at different time points (with F values respectively 860. 96 and 842. 09, P values below

  4. 46 CFR 7.20 - Nantucket Sound, Vineyard Sound, Buzzards Bay, Narragansett Bay, MA, Block Island Sound and...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Nantucket Sound, Vineyard Sound, Buzzards Bay, Narragansett Bay, MA, Block Island Sound and easterly entrance to Long Island Sound, NY. 7.20 Section 7.20... Atlantic Coast § 7.20 Nantucket Sound, Vineyard Sound, Buzzards Bay, Narragansett Bay, MA, Block Island...

  5. Lung Function Profiles among Individuals with Nonmalignant Asbestos-related Disorders

    Directory of Open Access Journals (Sweden)

    Eun-Kee Park

    2014-12-01

    Conclusion: Lung function measurement differs in individuals with different ARDs. Monitoring of lung function among asbestos-exposed populations is a simple means of facilitating earlier interventions.

  6. Loose parts monitoring system

    International Nuclear Information System (INIS)

    Wakasa, Kohji; Nishida, Eiichi; Ishii, Kazuo; Yamanaka, Hiroto.

    1987-01-01

    In the loose parts monitoring system (LPMS), installed for integrity monitoring of the nuclear power plants; when there occur foreign metallic objects in the reactor primary system, including a steam generator and the piping, the sounds caused by them moving with the cooling water and thereby getting in contact with various structures are detected. Its purpose is, therefore, to detect any abnormality in the reactor plant system through such abnormal sounds due to loose or fallen supports etc., and so provide this information to the reactor operators. In principle, accelerometers are distributed in such as reactor vessel, steam generator, coolant pumps, etc., so that various sounds are collected and converted into electrical signals, followed by analysis of the data. Described are the LPMS configuration/functions, the course taken in LPMS development, future problems, etc. (Mori, K.)

  7. Metagenomic profiling of microbial composition and antibiotic resistance determinants in Puget Sound.

    Science.gov (United States)

    Port, Jesse A; Wallace, James C; Griffith, William C; Faustman, Elaine M

    2012-01-01

    Human-health relevant impacts on marine ecosystems are increasing on both spatial and temporal scales. Traditional indicators for environmental health monitoring and microbial risk assessment have relied primarily on single species analyses and have provided only limited spatial and temporal information. More high-throughput, broad-scale approaches to evaluate these impacts are therefore needed to provide a platform for informing public health. This study uses shotgun metagenomics to survey the taxonomic composition and antibiotic resistance determinant content of surface water bacterial communities in the Puget Sound estuary. Metagenomic DNA was collected at six sites in Puget Sound in addition to one wastewater treatment plant (WWTP) that discharges into the Sound and pyrosequenced. A total of ~550 Mbp (1.4 million reads) were obtained, 22 Mbp of which could be assembled into contigs. While the taxonomic and resistance determinant profiles across the open Sound samples were similar, unique signatures were identified when comparing these profiles across the open Sound, a nearshore marina and WWTP effluent. The open Sound was dominated by α-Proteobacteria (in particular Rhodobacterales sp.), γ-Proteobacteria and Bacteroidetes while the marina and effluent had increased abundances of Actinobacteria, β-Proteobacteria and Firmicutes. There was a significant increase in the antibiotic resistance gene signal from the open Sound to marina to WWTP effluent, suggestive of a potential link to human impacts. Mobile genetic elements associated with environmental and pathogenic bacteria were also differentially abundant across the samples. This study is the first comparative metagenomic survey of Puget Sound and provides baseline data for further assessments of community composition and antibiotic resistance determinants in the environment using next generation sequencing technologies. In addition, these genomic signals of potential human impact can be used to guide initial

  8. Metagenomic profiling of microbial composition and antibiotic resistance determinants in Puget Sound.

    Directory of Open Access Journals (Sweden)

    Jesse A Port

    Full Text Available Human-health relevant impacts on marine ecosystems are increasing on both spatial and temporal scales. Traditional indicators for environmental health monitoring and microbial risk assessment have relied primarily on single species analyses and have provided only limited spatial and temporal information. More high-throughput, broad-scale approaches to evaluate these impacts are therefore needed to provide a platform for informing public health. This study uses shotgun metagenomics to survey the taxonomic composition and antibiotic resistance determinant content of surface water bacterial communities in the Puget Sound estuary. Metagenomic DNA was collected at six sites in Puget Sound in addition to one wastewater treatment plant (WWTP that discharges into the Sound and pyrosequenced. A total of ~550 Mbp (1.4 million reads were obtained, 22 Mbp of which could be assembled into contigs. While the taxonomic and resistance determinant profiles across the open Sound samples were similar, unique signatures were identified when comparing these profiles across the open Sound, a nearshore marina and WWTP effluent. The open Sound was dominated by α-Proteobacteria (in particular Rhodobacterales sp., γ-Proteobacteria and Bacteroidetes while the marina and effluent had increased abundances of Actinobacteria, β-Proteobacteria and Firmicutes. There was a significant increase in the antibiotic resistance gene signal from the open Sound to marina to WWTP effluent, suggestive of a potential link to human impacts. Mobile genetic elements associated with environmental and pathogenic bacteria were also differentially abundant across the samples. This study is the first comparative metagenomic survey of Puget Sound and provides baseline data for further assessments of community composition and antibiotic resistance determinants in the environment using next generation sequencing technologies. In addition, these genomic signals of potential human impact can be used

  9. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  10. Gefinex 400S (Sampo) EM-soundings at Olkiluoto 2008

    International Nuclear Information System (INIS)

    Jokinen, T.; Lehtimaeki, J.

    2008-09-01

    In the beginning of June 2008 Geological Survey of Finland (GTK) carried out electromagnetic frequency soundings with Gefinex 400S equipment (Sampo) in the vicinity of ONKALO at the Olkiluoto site investigation area. The same soundings sites were first time measured and marked in 2004 and has been repeated after it yearly in the same season. The aim of the measurements is to monitor the changes of groundwater conditions by the changes of the electric conductivity of the earth at ONKALO and repository area. The measurements form two 1400 m long broadside profiles, which have 200 m mutual distance and 200 m station separation. The profiles have been measured using 200, 500, and 800 m coil separations. Because of the strong electromagnetic noise all planned sites (48) could not be measured. In 2008 the measurements were performed at the sites that were successful in 2007 (43 soundings). The numerous power lines and cables in the area generate local disturbances on the sounding curves, but the signal/noise also with long coil separations and the repeatability of the results is reasonably good. However, most suitable for monitoring purposes are the sites without strong surficial 3D effects. Comparison of the results of 2004 to 2008 surveys shows differences on some ARD (Apparent resistivity-depth) curves. Those are mainly results of the modified man-made structures. The effects of changes in groundwater conditions are obviously slight. (orig.)

  11. Frequency shifting approach towards textual transcription of heartbeat sounds.

    Science.gov (United States)

    Arvin, Farshad; Doraisamy, Shyamala; Safar Khorasani, Ehsan

    2011-10-04

    Auscultation is an approach for diagnosing many cardiovascular problems. Automatic analysis of heartbeat sounds and extraction of its audio features can assist physicians towards diagnosing diseases. Textual transcription allows recording a continuous heart sound stream using a text format which can be stored in very small memory in comparison with other audio formats. In addition, a text-based data allows applying indexing and searching techniques to access to the critical events. Hence, the transcribed heartbeat sounds provides useful information to monitor the behavior of a patient for the long duration of time. This paper proposes a frequency shifting method in order to improve the performance of the transcription. The main objective of this study is to transfer the heartbeat sounds to the music domain. The proposed technique is tested with 100 samples which were recorded from different heart diseases categories. The observed results show that, the proposed shifting method significantly improves the performance of the transcription.

  12. Frequency shifting approach towards textual transcription of heartbeat sounds

    Directory of Open Access Journals (Sweden)

    Safar Khorasani Ehsan

    2011-10-01

    Full Text Available Abstract Auscultation is an approach for diagnosing many cardiovascular problems. Automatic analysis of heartbeat sounds and extraction of its audio features can assist physicians towards diagnosing diseases. Textual transcription allows recording a continuous heart sound stream using a text format which can be stored in very small memory in comparison with other audio formats. In addition, a text-based data allows applying indexing and searching techniques to access to the critical events. Hence, the transcribed heartbeat sounds provides useful information to monitor the behavior of a patient for the long duration of time. This paper proposes a frequency shifting method in order to improve the performance of the transcription. The main objective of this study is to transfer the heartbeat sounds to the music domain. The proposed technique is tested with 100 samples which were recorded from different heart diseases categories. The observed results show that, the proposed shifting method significantly improves the performance of the transcription.

  13. Patterns and correlates of adherence to self-monitoring in lung transplant recipients during the first 12 months after discharge from transplant.

    Science.gov (United States)

    Hu, Lu; DeVito Dabbs, Annette; Dew, Mary Amanda; Sereika, Susan M; Lingler, Jennifer H

    2017-08-01

    Self-monitoring of lung function, vital signs, and symptoms is crucial for lung transplant recipients (LTRs) to ensure early detection of complications and prompt intervention. This study sought to identify patterns and correlates of adherence to self-monitoring among LTRs over the first 12 months post-discharge from transplant. This study analyzed existing data from the usual care arm participants of a randomized clinical trial who tracked self-monitoring activities using paper-and-pencil logs. Adherence was calculated as the percent of days LTRs recorded any self-monitoring data per interval: hospital discharge-2 months, 3-6 months, and 7-12 months. The sample (N=91) was mostly white (87.9%), male (61.5%), with a mean age of 57.2±13.8 years. Group-based trajectory analyses revealed two groups: (i) moderately adherent with slow decline (n=29, 31.9%) and (ii) persistently nonadherent (n=62, 68.1%). Multivariate binary logistic regression revealed the following baseline factors increased the risk in the persistently nonadherent group: female (P=.035), higher anxiety (P=.008), and weaker sense of personal control over health (P=.005). Poorer physical health over 12 months were associated with increased risk in the persistently nonadherent group (P=.004). This study highlighted several modifiable factors for future interventions to target, including reducing post-transplant anxiety, and strengthening sense of personal control over health in LTRs. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Head and pelvic movement asymmetry during lungeing in horses with symmetrical movement on the straight.

    Science.gov (United States)

    Rhodin, M; Roepstorff, L; French, A; Keegan, K G; Pfau, T; Egenvall, A

    2016-05-01

    Lungeing is commonly used as part of standard lameness examinations in horses. Knowledge of how lungeing influences motion symmetry in sound horses is needed. The aim of this study was to objectively evaluate the symmetry of vertical head and pelvic motion during lungeing in a large number of horses with symmetric motion during straight line evaluation. Cross-sectional prospective study. A pool of 201 riding horses, all functioning well and considered sound by their owners, were evaluated in trot on a straight line and during lungeing to the left and right. From this pool, horses with symmetric vertical head and pelvic movement during the straight line trot (n = 94) were retained for analysis. Vertical head and pelvic movements were measured with body mounted uniaxial accelerometers. Differences between vertical maximum and minimum head (HDmax, HDmin) and pelvic (PDmax, PDmin) heights between left and right forelimb and hindlimb stances were compared between straight line trot and lungeing in either direction. Vertical head and pelvic movements during lungeing were more asymmetric than during trot on a straight line. Common asymmetric patterns seen in the head were more upward movement during push-off of the outside forelimb and less downward movement during impact of the inside limb. Common asymmetric patterns seen in the pelvis were less upward movement during push-off of the outside hindlimb and less downward movement of the pelvis during impact of the inside hindlimb. Asymmetric patterns in one lunge direction were frequently not the same as in the opposite direction. Lungeing induces systematic asymmetries in vertical head and pelvic motion patterns in horses that may not be the same in both directions. These asymmetries may mask or mimic fore- or hindlimb lameness. © 2015 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.

  15. Player Collaboration in the Explorative Sound Environment ToneInk

    DEFF Research Database (Denmark)

    Hansen, Anne-Marie S.; Andersen, Hans Jørgen; Raudaskoski, Pirkko Liisa

    2016-01-01

    mutual awareness, and in general were more passive when they needed to monitor a screen interface that supported the sound environment. Player collaboration was strongest when players negotiated rhythm, while the negotiation of melody was temporally offset and consisted of long individual explorations....

  16. Problems in nonlinear acoustics: Scattering of sound by sound, parametric receiving arrays, nonlinear effects in asymmetric sound beams and pulsed finite amplitude sound beams

    Science.gov (United States)

    Hamilton, Mark F.

    1989-08-01

    Four projects are discussed in this annual summary report, all of which involve basic research in nonlinear acoustics: Scattering of Sound by Sound, a theoretical study of two nonconlinear Gaussian beams which interact to produce sum and difference frequency sound; Parametric Receiving Arrays, a theoretical study of parametric reception in a reverberant environment; Nonlinear Effects in Asymmetric Sound Beams, a numerical study of two dimensional finite amplitude sound fields; and Pulsed Finite Amplitude Sound Beams, a numerical time domain solution of the KZK equation.

  17. PREFACE: Aerodynamic sound Aerodynamic sound

    Science.gov (United States)

    Akishita, Sadao

    2010-02-01

    The modern theory of aerodynamic sound originates from Lighthill's two papers in 1952 and 1954, as is well known. I have heard that Lighthill was motivated in writing the papers by the jet-noise emitted by the newly commercialized jet-engined airplanes at that time. The technology of aerodynamic sound is destined for environmental problems. Therefore the theory should always be applied to newly emerged public nuisances. This issue of Fluid Dynamics Research (FDR) reflects problems of environmental sound in present Japanese technology. The Japanese community studying aerodynamic sound has held an annual symposium since 29 years ago when the late Professor S Kotake and Professor S Kaji of Teikyo University organized the symposium. Most of the Japanese authors in this issue are members of the annual symposium. I should note the contribution of the two professors cited above in establishing the Japanese community of aerodynamic sound research. It is my pleasure to present the publication in this issue of ten papers discussed at the annual symposium. I would like to express many thanks to the Editorial Board of FDR for giving us the chance to contribute these papers. We have a review paper by T Suzuki on the study of jet noise, which continues to be important nowadays, and is expected to reform the theoretical model of generating mechanisms. Professor M S Howe and R S McGowan contribute an analytical paper, a valuable study in today's fluid dynamics research. They apply hydrodynamics to solve the compressible flow generated in the vocal cords of the human body. Experimental study continues to be the main methodology in aerodynamic sound, and it is expected to explore new horizons. H Fujita's study on the Aeolian tone provides a new viewpoint on major, longstanding sound problems. The paper by M Nishimura and T Goto on textile fabrics describes new technology for the effective reduction of bluff-body noise. The paper by T Sueki et al also reports new technology for the

  18. Say what? Coral reef sounds as indicators of community assemblages and reef conditions

    Science.gov (United States)

    Mooney, T. A.; Kaplan, M. B.

    2016-02-01

    Coral reefs host some of the highest diversity of life on the planet. Unfortunately, reef health and biodiversity is declining or is threatened as a result of climate change and human influences. Tracking these changes is necessary for effective resource management, yet estimating marine biodiversity and tracking trends in ecosystem health is a challenging and expensive task, especially in many pristine reefs which are remote and difficult to access. Many fishes, mammals and invertebrates make sound. These sounds are reflective of a number of vital biological processes and are a cue for settling reef larvae. Biological sounds may be a means to quantify ecosystem health and biodiversity, however the relationship between coral reef soundscapes and the actual taxa present remains largely unknown. This study presents a comparative evaluation of the soundscape of multiple reefs, naturally differing in benthic cover and fish diversity, in the U.S. Virgin Islands National Park. Using multiple recorders per reef we characterized spacio-temporal variation in biological sound production within and among reefs. Analyses of sounds recorded over 4 summer months indicated diel trends in both fish and snapping shrimp acoustic frequency bands with crepuscular peaks at all reefs. There were small but statistically significant acoustic differences among sites on a given reef raising the possibility of potentially localized acoustic habitats. The strength of diel trends in lower, fish-frequency bands were correlated with coral cover and fish density, yet no such relationship was found with shrimp sounds suggesting that fish sounds may be of higher relevance to tracking certain coral reef conditions. These findings indicate that, in spite of considerable variability within reef soundscapes, diel trends in low-frequency sound production reflect reef community assemblages. Further, monitoring soundscapes may be an efficient means of establishing and monitoring reef conditions.

  19. Study of the Acoustic Effects of Hydrokinetic Tidal Turbines in Admiralty Inlet, Puget Sound

    Energy Technology Data Exchange (ETDEWEB)

    Brian Polagye; Jim Thomson; Chris Bassett; Jason Wood; Dom Tollit; Robert Cavagnaro; Andrea Copping

    2012-03-30

    Hydrokinetic turbines will be a source of noise in the marine environment - both during operation and during installation/removal. High intensity sound can cause injury or behavioral changes in marine mammals and may also affect fish and invertebrates. These noise effects are, however, highly dependent on the individual marine animals; the intensity, frequency, and duration of the sound; and context in which the sound is received. In other words, production of sound is a necessary, but not sufficient, condition for an environmental impact. At a workshop on the environmental effects of tidal energy development, experts identified sound produced by turbines as an area of potentially significant impact, but also high uncertainty. The overall objectives of this project are to improve our understanding of the potential acoustic effects of tidal turbines by: (1) Characterizing sources of existing underwater noise; (2) Assessing the effectiveness of monitoring technologies to characterize underwater noise and marine mammal responsiveness to noise; (3) Evaluating the sound profile of an operating tidal turbine; and (4) Studying the effect of turbine sound on surrogate species in a laboratory environment. This study focuses on a specific case study for tidal energy development in Admiralty Inlet, Puget Sound, Washington (USA), but the methodologies and results are applicable to other turbine technologies and geographic locations. The project succeeded in achieving the above objectives and, in doing so, substantially contributed to the body of knowledge around the acoustic effects of tidal energy development in several ways: (1) Through collection of data from Admiralty Inlet, established the sources of sound generated by strong currents (mobilizations of sediment and gravel) and determined that low-frequency sound recorded during periods of strong currents is non-propagating pseudo-sound. This helped to advance the debate within the marine and hydrokinetics acoustic

  20. New perspectives in monitoring lung inflammation: analysis of exhaled breath condensate

    National Research Council Canada - National Science Library

    Montuschi, Paolo

    2005-01-01

    ... diseases might be relevant to differential diagnosis. Given its noninvasiveness, this method might be suitable for longitudinal studies in patients with lung disease, including children. This book provides an introduction to the analysis of exhaled breath condensate. To provide an overview of lung inflammation, basic and clinical pharmacology of leukotrie...

  1. Computerized Respiratory Sounds: Novel Outcomes for Pulmonary Rehabilitation in COPD.

    Science.gov (United States)

    Jácome, Cristina; Marques, Alda

    2017-02-01

    Computerized respiratory sounds are a simple and noninvasive measure to assess lung function. Nevertheless, their potential to detect changes after pulmonary rehabilitation (PR) is unknown and needs clarification if respiratory acoustics are to be used in clinical practice. Thus, this study investigated the short- and mid-term effects of PR on computerized respiratory sounds in subjects with COPD. Forty-one subjects with COPD completed a 12-week PR program and a 3-month follow-up. Secondary outcome measures included dyspnea, self-reported sputum, FEV 1 , exercise tolerance, self-reported physical activity, health-related quality of life, and peripheral muscle strength. Computerized respiratory sounds, the primary outcomes, were recorded at right/left posterior chest using 2 stethoscopes. Air flow was recorded with a pneumotachograph. Normal respiratory sounds, crackles, and wheezes were analyzed with validated algorithms. There was a significant effect over time in all secondary outcomes, with the exception of FEV 1 and of the impact domain of the St George Respiratory Questionnaire. Inspiratory and expiratory median frequencies of normal respiratory sounds in the 100-300 Hz band were significantly lower immediately (-2.3 Hz [95% CI -4 to -0.7] and -1.9 Hz [95% CI -3.3 to -0.5]) and at 3 months (-2.1 Hz [95% CI -3.6 to -0.7] and -2 Hz [95% CI -3.6 to -0.5]) post-PR. The mean number of expiratory crackles (-0.8, 95% CI -1.3 to -0.3) and inspiratory wheeze occupation rate (median 5.9 vs 0) were significantly lower immediately post-PR. Computerized respiratory sounds were sensitive to short- and mid-term effects of PR in subjects with COPD. These findings are encouraging for the clinical use of respiratory acoustics. Future research is needed to strengthen these findings and explore the potential of computerized respiratory sounds to assess the effectiveness of other clinical interventions in COPD. Copyright © 2017 by Daedalus Enterprises.

  2. Characteristic patterns in the fibrotic lung. Comparing idiopathic pulmonary fibrosis with chronic lung allograft dysfunction.

    Science.gov (United States)

    Fernandez, Isis E; Heinzelmann, Katharina; Verleden, Stijn; Eickelberg, Oliver

    2015-03-01

    Tissue fibrosis, a major cause of death worldwide, leads to significant organ dysfunction in any organ of the human body. In the lung, fibrosis critically impairs gas exchange, tissue oxygenation, and immune function. Idiopathic pulmonary fibrosis (IPF) is the most detrimental and lethal fibrotic disease of the lung, with an estimated median survival of 50% after 3-5 years. Lung transplantation currently remains the only therapeutic alternative for IPF and other end-stage pulmonary disorders. Posttransplant lung function, however, is compromised by short- and long-term complications, most importantly chronic lung allograft dysfunction (CLAD). CLAD affects up to 50% of all transplanted lungs after 5 years, and is characterized by small airway obstruction with pronounced epithelial injury, aberrant wound healing, and subepithelial and interstitial fibrosis. Intriguingly, the mechanisms leading to the fibrotic processes in the engrafted lung exhibit striking similarities to those in IPF; therefore, antifibrotic therapies may contribute to increased graft function and survival in CLAD. In this review, we focus on these common fibrosis-related mechanisms in IPF and CLAD, comparing and contrasting clinical phenotypes, the mechanisms of fibrogenesis, and biomarkers to monitor, predict, or prognosticate disease status.

  3. Magnetic induction pneumography: a planar coil system for continuous monitoring of lung function via contactless measurements

    Directory of Open Access Journals (Sweden)

    Doga Gursoy

    2010-11-01

    Full Text Available Continuous monitoring of lung function is of particular interest to the mechanically ventilated patients during critical care. Recent studies have shown that magnetic induction measurements with single coils provide signals which are correlated with the lung dynamics and this idea is extended here by using a 5 by 5 planar coil matrix for data acquisition in order to image the regional thoracic conductivity changes. The coil matrix can easily be mounted onto the patient bed, and thus, the problems faced in methods that use contacting sensors can readily be eliminated and the patient comfort can be improved. In the proposed technique, the data are acquired by successively exciting each coil in order to induce an eddy-current density within the dorsal tissues and measuring the corresponding response magnetic field strength by the remaining coils. The recorded set of data is then used to reconstruct the internal conductivity distribution by means of algorithms that minimize the residual norm between the estimated and measured data. To investigate the feasibility of the technique, the sensitivity maps and the point spread functions at different locations and depths were studied. To simulate a realistic scenario, a chest model was generated by segmenting the tissue boundaries from NMR images. The reconstructions of the ventilation distribution and the development of an edematous lung injury were presented. The imaging artifacts caused by either the incorrect positioning of the patient or the expansion of the chest wall due to breathing were illustrated by simulations.

  4. An acoustical model based monitoring network

    NARCIS (Netherlands)

    Wessels, P.W.; Basten, T.G.H.; Eerden, F.J.M. van der

    2010-01-01

    In this paper the approach for an acoustical model based monitoring network is demonstrated. This network is capable of reconstructing a noise map, based on the combination of measured sound levels and an acoustic model of the area. By pre-calculating the sound attenuation within the network the

  5. Frog sound identification using extended k-nearest neighbor classifier

    Science.gov (United States)

    Mukahar, Nordiana; Affendi Rosdi, Bakhtiar; Athiar Ramli, Dzati; Jaafar, Haryati

    2017-09-01

    Frog sound identification based on the vocalization becomes important for biological research and environmental monitoring. As a result, different types of feature extractions and classifiers have been employed to evaluate the accuracy of frog sound identification. This paper presents a frog sound identification with Extended k-Nearest Neighbor (EKNN) classifier. The EKNN classifier integrates the nearest neighbors and mutual sharing of neighborhood concepts, with the aims of improving the classification performance. It makes a prediction based on who are the nearest neighbors of the testing sample and who consider the testing sample as their nearest neighbors. In order to evaluate the classification performance in frog sound identification, the EKNN classifier is compared with competing classifier, k -Nearest Neighbor (KNN), Fuzzy k -Nearest Neighbor (FKNN) k - General Nearest Neighbor (KGNN)and Mutual k -Nearest Neighbor (MKNN) on the recorded sounds of 15 frog species obtained in Malaysia forest. The recorded sounds have been segmented using Short Time Energy and Short Time Average Zero Crossing Rate (STE+STAZCR), sinusoidal modeling (SM), manual and the combination of Energy (E) and Zero Crossing Rate (ZCR) (E+ZCR) while the features are extracted by Mel Frequency Cepstrum Coefficient (MFCC). The experimental results have shown that the EKNCN classifier exhibits the best performance in terms of accuracy compared to the competing classifiers, KNN, FKNN, GKNN and MKNN for all cases.

  6. Lung function imaging methods in Cystic Fibrosis pulmonary disease.

    Science.gov (United States)

    Kołodziej, Magdalena; de Veer, Michael J; Cholewa, Marian; Egan, Gary F; Thompson, Bruce R

    2017-05-17

    Monitoring of pulmonary physiology is fundamental to the clinical management of patients with Cystic Fibrosis. The current standard clinical practise uses spirometry to assess lung function which delivers a clinically relevant functional readout of total lung function, however does not supply any visible or localised information. High Resolution Computed Tomography (HRCT) is a well-established current 'gold standard' method for monitoring lung anatomical changes in Cystic Fibrosis patients. HRCT provides excellent morphological information, however, the X-ray radiation dose can become significant if multiple scans are required to monitor chronic diseases such as cystic fibrosis. X-ray phase-contrast imaging is another emerging X-ray based methodology for Cystic Fibrosis lung assessment which provides dynamic morphological and functional information, albeit with even higher X-ray doses than HRCT. Magnetic Resonance Imaging (MRI) is a non-ionising radiation imaging method that is garnering growing interest among researchers and clinicians working with Cystic Fibrosis patients. Recent advances in MRI have opened up the possibilities to observe lung function in real time to potentially allow sensitive and accurate assessment of disease progression. The use of hyperpolarized gas or non-contrast enhanced MRI can be tailored to clinical needs. While MRI offers significant promise it still suffers from poor spatial resolution and the development of an objective scoring system especially for ventilation assessment.

  7. SU-E-T-551: Monitor Unit Optimization in Stereotactic Body Radiation Therapy for Stage I Lung Cancer

    International Nuclear Information System (INIS)

    Huang, B-T; Lu, J-Y

    2015-01-01

    Purpose: The study aims to reduce the monitor units (MUs) in the stereotactic body radiation therapy (SBRT) treatment for lung cancer by adjusting the optimizing parameters. Methods: Fourteen patients suffered from stage I Non-Small Cell Lung Cancer (NSCLC) were enrolled. Three groups of parameters were adjusted to investigate their effects on MU numbers and organs at risk (OARs) sparing: (1) the upper objective of planning target volume (UOPTV); (2) strength setting in the MU constraining objective; (3) max MU setting in the MU constraining objective. Results: We found that the parameters in the optimizer influenced the MU numbers in a priority, strength and max MU dependent manner. MU numbers showed a decreasing trend with the UOPTV increasing. MU numbers with low, medium and high priority for the UOPTV were 428±54, 312±48 and 258±31 MU/Gy, respectively. High priority for UOPTV also spared the heart, cord and lung while maintaining comparable PTV coverage than the low and medium priority group. It was observed that MU numbers tended to decrease with the strength increasing and max MU setting decreasing. With maximum strength, the MU numbers reached its minimum while maintaining comparable or improved dose to the normal tissues. It was also found that the MU numbers continued to decline at 85% and 75% max MU setting but no longer to decrease at 50% and 25%. Combined with high priority for UOPTV and MU constraining objectives, the MU numbers can be decreased as low as 223±26 MU/Gy. Conclusion:: The priority of UOPTV, MU constraining objective in the optimizer impact on the MU numbers in SBRT treatment for lung cancer. Giving high priority to the UOPTV, setting the strength to maximum value and the max MU to 50% in the MU objective achieves the lowest MU numbers while maintaining comparable or improved OAR sparing

  8. "Open lung ventilation optimizes pulmonary function during lung surgery".

    Science.gov (United States)

    Downs, John B; Robinson, Lary A; Steighner, Michael L; Thrush, David; Reich, Richard R; Räsänen, Jukka O

    2014-12-01

    We evaluated an "open lung" ventilation (OV) strategy using low tidal volumes, low respiratory rate, low FiO2, and high continuous positive airway pressure in patients undergoing major lung resections. In this phase I pilot study, twelve consecutive patients were anesthetized using conventional ventilator settings (CV) and then OV strategy during which oxygenation and lung compliance were noted. Subsequently, a lung resection was performed. Data were collected during both modes of ventilation in each patient, with each patient acting as his own control. The postoperative course was monitored for complications. Twelve patients underwent open thoracotomies for seven lobectomies and five segmentectomies. The OV strategy provided consistent one-lung anesthesia and improved static compliance (40 ± 7 versus 25 ± 4 mL/cm H2O, P = 0.002) with airway pressures similar to CV. Postresection oxygenation (SpO2/FiO2) was better during OV (433 ± 11 versus 386 ± 15, P = 0.008). All postoperative chest x-rays were free of atelectasis or infiltrates. No patient required supplemental oxygen at any time postoperatively or on discharge. The mean hospital stay was 4 ± 1 d. There were no complications or mortality. The OV strategy, previously shown to have benefits during mechanical ventilation of patients with respiratory failure, proved safe and effective in lung resection patients. Because postoperative pulmonary complications may be directly attributable to the anesthetic management, adopting an OV strategy that optimizes lung mechanics and gas exchange may help reduce postoperative problems and improve overall surgical results. A randomized trial is planned to ascertain whether this technique will reduce postoperative pulmonary complications. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Dutch Lung Surgery Audit: A National Audit Comprising Lung and Thoracic Surgery Patients.

    Science.gov (United States)

    Berge, Martijn Ten; Beck, Naomi; Heineman, David Jonathan; Damhuis, Ronald; Steup, Willem Hans; van Huijstee, Pieter Jan; Eerenberg, Jan Peter; Veen, Eelco; Maat, Alexander; Versteegh, Michel; van Brakel, Thomas; Schreurs, Wilhemina Hendrika; Wouters, Michel Wilhelmus

    2018-04-21

    The nationwide Dutch Lung Surgery Audit (DLSA) started in 2012 to monitor and evaluate the quality of lung surgery in the Netherlands as an improvement tool. This outline describes the establishment, structure and organization of the audit by the Dutch Society of Lung Surgeons (NVvL) and the Dutch Society of Cardiothoracic Surgeons (NVT), in collaboration with the Dutch Institute for Clinical Auditing (DICA). In addition, first four-year results are presented. The NVvL and NVT initiated a web-based registration including weekly updated online feedback for participating hospitals. Data verification by external data managers is performed on regular basis. The audit is incorporated in national quality improvement programs and participation in the DLSA is mandatory by health insurance organizations and the National Healthcare Inspectorate. Between 1 January 2012 and 31 December 2015, all hospitals performing lung surgery participated and a total of 19,557 patients were registered from which almost half comprised lung cancer patients. Nationwide the guideline adherence increased over the years and 96.5% of lung cancer patients were discussed in preoperative multidisciplinary teams. Overall postoperative complications and mortality after non-small cell lung cancer surgery were 15.5% and 2.0%, respectively. The audit provides reliable benchmarked information for caregivers and hospital management with potential to start local, regional or national improvement initiatives. Currently, the audit is further completed with data from non-surgical lung cancer patients including treatment data from pulmonary oncologists and radiation oncologists. This will ultimately provide a comprehensive overview of lung cancer treatment in The Netherlands. Copyright © 2018. Published by Elsevier Inc.

  10. Annual Report: 2010-2011 Storm Season Sampling For NON-DRY DOCK STORMWATER MONITORING FOR PUGET SOUND NAVAL SHIPYARD, BREMERTON, WA

    Energy Technology Data Exchange (ETDEWEB)

    Brandenberger, Jill M.; Metallo, David; Johnston, Robert K.; Gebhardt, Christine; Hsu, Larry

    2012-09-01

    This interim report summarizes the stormwater monitoring conducted for non-dry dock outfalls in both the confined industrial area and the residential areas of Naval Base Kitsap within the Puget Sound Naval Shipyard (referred to as the Shipyard). This includes the collection, analyses, and descriptive statistics for stormwater sampling conducted from November 2010 through April 2011. Seven stormwater basins within the Shipyard were sampled during at least three storm events to characterize non-dry dock stormwater discharges at selected stormwater drains located within the facility. This serves as the Phase I component of the project and Phase II is planned for the 2011-2012 storm season. These data will assist the Navy, USEPA, Ecology and other stakeholders in understanding the nature and condition of stormwater discharges from the Shipyard and inform the permitting process for new outfall discharges. The data from Phase I was compiled with current stormwater data available from the Shipyard, Sinclair/Dyes Inlet watershed, and Puget Sound in order to support technical investigations for the Draft NPDES permit. The permit would require storm event sampling at selected stormwater drains located within the Shipyard. However, the data must be considered on multiple scales to truly understand potential impairments to beneficial uses within Sinclair and Dyes Inlets.

  11. The Effect of Compartmental Asymmetry on the Monitoring of Pulmonary Mechanics and Lung Volumes.

    Science.gov (United States)

    Keenan, Joseph C; Cortes-Puentes, Gustavo A; Adams, Alexander B; Dries, David J; Marini, John J

    2016-11-01

    Esophageal pressure measurement for computation of transpulmonary pressure (P tp ) has begun to be incorporated into clinical use for evaluating forces across the lungs. Gaps exist in our understanding of how esophageal pressure (and therefore P tp ), a value measured at a single site, responds when respiratory system compartments are asymmetrically affected by whole-lung atelectasis or unilateral injury as well as changes in chest wall compliance. We reasoned that P tp would track with aerated volume changes as estimated by functional residual capacity (FRC) and tidal volume. We examined this hypothesis in the setting of asymmetric lungs and changes in intra-abdominal pressure. This study was conducted in the animal laboratory of a university-affiliated hospital. Models of unilateral atelectasis and unilateral and bilateral lung injury exposed to intra-abdominal hypertension (IAH) in 10 deeply sedated mechanically ventilated swine. Atelectasis was created by balloon occlusion of the left main bronchus. Unilateral lung injury was induced by saline lavage of isolated right lung. Diffuse lung injury was induced by saline lavage of both lungs. The peritoneum was insufflated with air to create a model of pressure-regulated IAH. We measured esophageal pressures, airway pressures, FRC by gas dilution, and oxygenation. FRC was reduced by IAH in normal lungs (P volume in the setting of thoracic asymmetry and changes in intra-abdominal pressure. However, used alone, it cannot distinguish the relative contributions of air-space distention and recruitment of lung units. Copyright © 2016 by Daedalus Enterprises.

  12. Monitoring of bunker fuel consumption

    Energy Technology Data Exchange (ETDEWEB)

    Faber, J.; Nelissen, D.; Smit, M.

    2013-03-15

    Monitoring of fuel consumption and greenhouse gas emissions from international shipping is currently under discussion at the EU level as well as at the IMO (International Maritime Organization). There are several approaches to monitoring, each with different characteristics. Based on a survey of the literature and information from equipment suppliers, this report analyses the four main methods for monitoring emissions: (1) Bunker delivery notes (i.e. a note provided by the bunker fuel supplier specifying, inter alia, the amount of fuel bunkered); (2) Tank sounding (i.e. systems for measuring the amount of fuel in the fuel tanks); (3) Fuel flow meters (i.e. systems for measuring the amount of fuel supplied to the engines, generators or boilers); and (4) Direct emissions monitoring (i.e. measuring the exhaust emissions in the stack). The report finds that bunker delivery notes and tank soundings have the lowest investment cost. However, unless tank sounding is automated, these systems have higher operational costs than fuel flow meters or direct emissions monitoring because manual readings have to be entered in monitoring systems. Fuel flow meters have the highest potential accuracy. Depending on the technology selected, their accuracy can be an order of magnitude better than the other systems, which typically have errors of a few percent. By providing real-time feed-back on fuel use or emissions, fuel flow meters and direct emissions monitoring provide ship operators with the means to train their crew to adopt fuel-efficient sailing methods and to optimise their maintenance and hull cleaning schedules. Except for bunker delivery notes, all systems allow for both time-based and route-based (or otherwise geographically delineated) systems.

  13. Imagining Sound

    DEFF Research Database (Denmark)

    Grimshaw, Mark; Garner, Tom Alexander

    2014-01-01

    We make the case in this essay that sound that is imagined is both a perception and as much a sound as that perceived through external stimulation. To argue this, we look at the evidence from auditory science, neuroscience, and philosophy, briefly present some new conceptual thinking on sound...... that accounts for this view, and then use this to look at what the future might hold in the context of imagining sound and developing technology....

  14. Lung structure and function relation in systemic sclerosis: Application of lung densitometry

    Energy Technology Data Exchange (ETDEWEB)

    Ninaber, Maarten K., E-mail: m.k.ninaber@lumc.nl [Department of Pulmonology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Stolk, Jan; Smit, Jasper; Le Roy, Ernest J. [Department of Pulmonology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Kroft, Lucia J.M. [Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Els Bakker, M. [Division of Image Processing, Radiology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Vries Bouwstra, Jeska K. de; Schouffoer, Anne A. [Department of Rheumatology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Staring, Marius; Stoel, Berend C. [Division of Image Processing, Radiology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands)

    2015-05-15

    Highlights: • A quantitative CT parameter of lung parenchyma in systemic sclerosis is presented. • We examine the optimal percentage threshold for the percentile density. • The 85th percentile density threshold correlated significantly with lung function. • A lung structure–function relation is confirmed. • We report applicability of Perc85 in progression mapping of interstitial lung disease. - Abstract: Introduction: Interstitial lung disease occurs frequently in patients with systemic sclerosis (SSc). Quantitative computed tomography (CT) densitometry using the percentile density method may provide a sensitive assessment of lung structure for monitoring parenchymal damage. Therefore, we aimed to evaluate the optimal percentile density score in SSc by quantitative CT densitometry, against pulmonary function. Material and methods: We investigated 41 SSc patients by chest CT scan, spirometry and gas transfer tests. Lung volumes and the nth percentile density (between 1 and 99%) of the entire lungs were calculated from CT histograms. The nth percentile density is defined as the threshold value of densities expressed in Hounsfield units. A prerequisite for an optimal percentage was its correlation with baseline DLCO %predicted. Two patients showed distinct changes in lung function 2 years after baseline. We obtained CT scans from these patients and performed progression analysis. Results: Regression analysis for the relation between DLCO %predicted and the nth percentile density was optimal at 85% (Perc85). There was significant agreement between Perc85 and DLCO %predicted (R = −0.49, P = 0.001) and FVC %predicted (R = −0.64, P < 0.001). Two patients showed a marked change in Perc85 over a 2 year period, but the localization of change differed clearly. Conclusions: We identified Perc85 as optimal lung density parameter, which correlated significantly with DLCO and FVC, confirming a lung parenchymal structure–function relation in SSc. This provides

  15. Lung structure and function relation in systemic sclerosis: Application of lung densitometry

    International Nuclear Information System (INIS)

    Ninaber, Maarten K.; Stolk, Jan; Smit, Jasper; Le Roy, Ernest J.; Kroft, Lucia J.M.; Els Bakker, M.; Vries Bouwstra, Jeska K. de; Schouffoer, Anne A.; Staring, Marius; Stoel, Berend C.

    2015-01-01

    Highlights: • A quantitative CT parameter of lung parenchyma in systemic sclerosis is presented. • We examine the optimal percentage threshold for the percentile density. • The 85th percentile density threshold correlated significantly with lung function. • A lung structure–function relation is confirmed. • We report applicability of Perc85 in progression mapping of interstitial lung disease. - Abstract: Introduction: Interstitial lung disease occurs frequently in patients with systemic sclerosis (SSc). Quantitative computed tomography (CT) densitometry using the percentile density method may provide a sensitive assessment of lung structure for monitoring parenchymal damage. Therefore, we aimed to evaluate the optimal percentile density score in SSc by quantitative CT densitometry, against pulmonary function. Material and methods: We investigated 41 SSc patients by chest CT scan, spirometry and gas transfer tests. Lung volumes and the nth percentile density (between 1 and 99%) of the entire lungs were calculated from CT histograms. The nth percentile density is defined as the threshold value of densities expressed in Hounsfield units. A prerequisite for an optimal percentage was its correlation with baseline DLCO %predicted. Two patients showed distinct changes in lung function 2 years after baseline. We obtained CT scans from these patients and performed progression analysis. Results: Regression analysis for the relation between DLCO %predicted and the nth percentile density was optimal at 85% (Perc85). There was significant agreement between Perc85 and DLCO %predicted (R = −0.49, P = 0.001) and FVC %predicted (R = −0.64, P < 0.001). Two patients showed a marked change in Perc85 over a 2 year period, but the localization of change differed clearly. Conclusions: We identified Perc85 as optimal lung density parameter, which correlated significantly with DLCO and FVC, confirming a lung parenchymal structure–function relation in SSc. This provides

  16. Monotonicity-based electrical impedance tomography for lung imaging

    Science.gov (United States)

    Zhou, Liangdong; Harrach, Bastian; Seo, Jin Keun

    2018-04-01

    This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography (EIT). The EIT data (i.e. the boundary current-voltage data) can be decomposed into pulmonary, cardiac and other parts using their different periodic natures. The time-differential current-voltage operator corresponding to the lung ventilation can be viewed as either semi-positive or semi-negative definite owing to monotonic conductivity changes within the lung regions. We used these monotonicity constraints to improve the quality of lung EIT imaging. We tested the proposed methods in numerical simulations, phantom experiments and human experiments.

  17. A Comparative Study of the Monitoring of a Self Aligning Spherical Journal using Surface Vibration, Airborne Sound and Acoustic Emission

    International Nuclear Information System (INIS)

    Raharjo, P; Tesfa, B; Gu, F; Ball, A D

    2012-01-01

    A Self aligning spherical journal bearing is a plain bearing which has spherical surface contact that can be applied in high power industrial machinery. This type of bearing can accommodate a misalignment problem. The journal bearing faults degrade machine performance, decrease life time service and cause unexpected failure which are dangerous for safety issues. Non-intrusive measurements such as surface vibration (SV), airborne sound (AS) and acoustic emission (AE) measurement are appropriate monitoring methods for early stage journal bearing fault in low, medium and high frequency. This paper focuses on the performance comparison using SV, AS and AE measurements in monitoring a self aligning spherical journal bearing for normal and faulty (scratch) conditions. It examines the signals in the time domain and frequency domain and identifies the frequency ranges for each measurement in which significant changes are observed. The results of SV, AS and AE experiments indicate that the spectrum can be used to detect the differences between normal and faulty bearing. The statistic parameter shows that RMS value and peak value for faulty bearing is higher than normal bearing.

  18. Lung transplantation in children. Specific aspects.

    Science.gov (United States)

    Moreno Galdó, Antonio; Solé Montserrat, Juan; Roman Broto, Antonio

    2013-12-01

    Lung transplantation has become in recent years a therapeutic option for infantswith terminal lung disease with similar results to transplantation in adults.In Spain, since 1996 114 children lung transplants have been performed; this corresponds to3.9% of the total transplant number.The most common indication in children is cystic fibrosis, which represents between 70-80% of the transplants performed in adolescents. In infants common indications areinterstitial lung disease and pulmonary hypertension.In most children a sequential double lung transplant is performed, generally with the help ofextracorporeal circulation. Lung transplantation in children presents special challenges in monitoring and follow-up, especially in infants, given the difficulty in assessing lung function and performing transbronchial biopsies.There are some more specific complications in children like postransplant lymphoproliferative syndrome or a greater severity of respiratory virus infections .After lung transplantation children usually experiment a very important improvement in their quality of life. Eighty eight per cent of children have no limitations in their activity after 3 years of transplantation.According to the registry of the International Society for Heart & Lung Transplantation (ISHLT) survival at 5 years of transplantation is 54% and at 10 years is around 35%. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  19. Medical image of the week: achalasia with lung abscess

    Directory of Open Access Journals (Sweden)

    Tey KR

    2016-05-01

    Full Text Available No abstract available. Article truncated after 150 words. An 80-year old woman with past medical history of high grade serous fallopian tube carcinoma presented with 2 months history of productive cough. This was associated with shortness of breath and subjective fever, chills and weight loss of 5 pounds over 2 months. She was treated with outpatient antibiotics without improvement of symptoms. Patient was afebrile on presentation, hemodynamically stable, and saturating at 99% on room air. Lung examinations revealed dullness on percussion of left lower lung field and reduced breath sounds on the same area. Computed tomographic imaging revealed a large lung abscess on left lower lobe (Figure 1 and moderately dilated esophagus and fluid filled to the level of gastro-esophagus junction. Barium swallow study showed a classic bird-beak like appearance (Figure 2. There was no contrast that passed through the gastro-esophagus junction during the entire course of the barium study. Upper endoscopy was performed to rule out intraluminal ...

  20. Do top predators cue on sound production by mesopelagic prey?

    Science.gov (United States)

    Baumann-Pickering, S.; Checkley, D. M., Jr.; Demer, D. A.

    2016-02-01

    Deep-scattering layer (DSL) organisms, comprising a variety of mesopelagic fishes, and squids, siphonophores, crustaceans, and other invertebrates, are preferred prey for numerous large marine predators, e.g. cetaceans, seabirds, and fishes. Some of the DSL species migrate from depth during daylight to feed near the surface at night, transitioning during dusk and dawn. We investigated if any DSL organisms create sound, particularly during the crepuscular periods. Over several nights in summer 2015, underwater sound was recorded in the San Diego Trough using a high-frequency acoustic recording package (HARP, 10 Hz to 100 kHz), suspended from a drifting surface float. Acoustic backscatter from the DSL was monitored nearby using a calibrated multiple-frequency (38, 70, 120, and 200 kHz) split-beam echosounder (Simrad EK60) on a small boat. DSL organisms produced sound, between 300 and 1000 Hz, and the received levels were highest when the animals migrated past the recorder during ascent and descent. The DSL are globally present, so the observed acoustic phenomenon, if also ubiquitous, has wide-reaching implications. Sound travels farther than light or chemicals and thus can be sensed at greater distances by predators, prey, and mates. If sound is a characteristic feature of pelagic ecosystems, it likely plays a role in predator-prey relationships and overall ecosystem dynamics. Our new finding inspires numerous questions such as: Which, how, and why have DSL organisms evolved to create sound, for what do they use it and under what circumstances? Is sound production by DSL organisms truly ubiquitous, or does it depend on the local environment and species composition? How may sound production and perception be adapted to a changing environment? Do predators react to changes in sound? Can sound be used to quantify the composition of mixed-species assemblages, component densities and abundances, and hence be used in stock assessment or predictive modeling?

  1. Sound radiation contrast in MR phase images. Method for the representation of elasticity, sound damping, and sound impedance changes

    International Nuclear Information System (INIS)

    Radicke, Marcus

    2009-01-01

    The method presented in this thesis combines ultrasound techniques with the magnetic-resonance tomography (MRT). An ultrasonic wave generates in absorbing media a static force in sound-propagation direction. The force leads at sound intensities of some W/cm 2 and a sound frequency in the lower MHz range to a tissue shift in the micrometer range. This tissue shift depends on the sound power, the sound frequency, the sound absorption, and the elastic properties of the tissue. A MRT sequence of the Siemens Healthcare AG was modified so that it measures (indirectly) the tissue shift, codes as grey values, and presents as 2D picture. By means of the grey values the sound-beam slope in the tissue can be visualized, and so additionally sound obstacles (changes of the sound impedance) can be detected. By the MRT images token up spatial changes of the tissue parameters sound absorption and elasticity can be detected. In this thesis measurements are presented, which show the feasibility and future chances of this method especially for the mammary-cancer diagnostics. [de

  2. Wearable Eating Habit Sensing System Using Internal Body Sound

    Science.gov (United States)

    Shuzo, Masaki; Komori, Shintaro; Takashima, Tomoko; Lopez, Guillaume; Tatsuta, Seiji; Yanagimoto, Shintaro; Warisawa, Shin'ichi; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of eating habits could be useful in preventing lifestyle diseases such as metabolic syndrome. Conventional methods consist of self-reporting and calculating mastication frequency based on the myoelectric potential of the masseter muscle. Both these methods are significant burdens for the user. We developed a non-invasive, wearable sensing system that can record eating habits over a long period of time in daily life. Our sensing system is composed of two bone conduction microphones placed in the ears that send internal body sound data to a portable IC recorder. Applying frequency spectrum analysis on the collected sound data, we could not only count the number of mastications during eating, but also accurately differentiate between eating, drinking, and speaking activities. This information can be used to evaluate the regularity of meals. Moreover, we were able to analyze sound features to classify the types of foods eaten by food texture.

  3. Understanding Animal Detection of Precursor Earthquake Sounds.

    Science.gov (United States)

    Garstang, Michael; Kelley, Michael C

    2017-08-31

    We use recent research to provide an explanation of how animals might detect earthquakes before they occur. While the intrinsic value of such warnings is immense, we show that the complexity of the process may result in inconsistent responses of animals to the possible precursor signal. Using the results of our research, we describe a logical but complex sequence of geophysical events triggered by precursor earthquake crustal movements that ultimately result in a sound signal detectable by animals. The sound heard by animals occurs only when metal or other surfaces (glass) respond to vibrations produced by electric currents induced by distortions of the earth's electric fields caused by the crustal movements. A combination of existing measurement systems combined with more careful monitoring of animal response could nevertheless be of value, particularly in remote locations.

  4. The Influence of Fundamental Frequency and Sound Pressure Level Range on Breathing Patterns in Female Classical Singing

    Science.gov (United States)

    Collyer, Sally; Thorpe, C. William; Callaghan, Jean; Davis, Pamela J.

    2008-01-01

    Purpose: This study investigated the influence of fundamental frequency (F0) and sound pressure level (SPL) range on respiratory behavior in classical singing. Method: Five trained female singers performed an 8-s messa di voce (a crescendo and decrescendo on one F0) across their musical F0 range. Lung volume (LV) change was estimated, and…

  5. Heart sounds analysis via esophageal stethoscope system in beagles.

    Science.gov (United States)

    Park, Sang Hi; Shin, Young Duck; Bae, Jin Ho; Kwon, Eun Jung; Lee, Tae-Soo; Shin, Ji-Yun; Kim, Yeong-Cheol; Min, Gyeong-Deuk; Kim, Myoung hwan

    2013-10-01

    Esophageal stethoscope is less invasive and easy to handling. And it gives a lot of information. The purpose of this study is to investigate the correlation of blood pressure and heart sound as measured by esophageal stethoscope. Four male beagles weighing 10 to 12 kg were selected as experimental subjects. After general anesthesia, the esophageal stethoscope was inserted. After connecting the microphone, the heart sounds were visualized and recorded through a self-developed equipment and program. The amplitudes of S1 and S2 were monitored real-time to examine changes as the blood pressure increased and decreased. The relationship between the ratios of S1 to S2 (S1/S2) and changes in blood pressure due to ephedrine was evaluated. The same experiment was performed with different concentration of isoflurane. From S1 and S2 in the inotropics experiment, a high correlation appeared with change in blood pressure in S1. The relationship between S1/S2 and change in blood pressure showed a positive correlation in each experimental subject. In the volatile anesthetics experiment, the heart sounds decreased as MAC increased. Heart sounds were analyzed successfully with the esophageal stethoscope through the self-developed program and equipment. A proportional change in heart sounds was confirmed when blood pressure was changed using inotropics or volatile anesthetics. The esophageal stethoscope can achieve the closest proximity to the heart to hear sounds in a non-invasive manner.

  6. Velocity of sound measurements in gaseous per-fluorocarbons and their custom mixtures

    CERN Document Server

    Vacek, V; Lindsay, S

    2000-01-01

    An inexpensive sonar instrument was prepared for measurements of sound velocity in two fluorocarbon vapors; per-fluoro-n-propane (C3F8), per-fluoro-n-butane (C4F10), and their custom mixtures. The apparatus, measurement principle and instrument software are described. All sound velocity measurements in per-fluorocarbons were made in the low pressure range between 0.01 and 0.4 MPa, and at temperatures between 253 and 303 K. The purity of the C3F8 and C4F10 samples was checked using gas chromatography. Uncertainties in the speed of sound measurements were better than ± 0.1 %. Comparisons were made with theoretical predictions of sound velocity for the two individual components. The instrument was then used for concentration monitoring of custom C3F8/C4F10 mixtures.

  7. The attractor recurrent neural network based on fuzzy functions: An effective model for the classification of lung abnormalities.

    Science.gov (United States)

    Khodabakhshi, Mohammad Bagher; Moradi, Mohammad Hassan

    2017-05-01

    The respiratory system dynamic is of high significance when it comes to the detection of lung abnormalities, which highlights the importance of presenting a reliable model for it. In this paper, we introduce a novel dynamic modelling method for the characterization of the lung sounds (LS), based on the attractor recurrent neural network (ARNN). The ARNN structure allows the development of an effective LS model. Additionally, it has the capability to reproduce the distinctive features of the lung sounds using its formed attractors. Furthermore, a novel ARNN topology based on fuzzy functions (FFs-ARNN) is developed. Given the utility of the recurrent quantification analysis (RQA) as a tool to assess the nature of complex systems, it was used to evaluate the performance of both the ARNN and the FFs-ARNN models. The experimental results demonstrate the effectiveness of the proposed approaches for multichannel LS analysis. In particular, a classification accuracy of 91% was achieved using FFs-ARNN with sequences of RQA features. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. The influence of neonatal intensive care unit design on sound level.

    Science.gov (United States)

    Chen, Hsin-Li; Chen, Chao-Huei; Wu, Chih-Chao; Huang, Hsiu-Jung; Wang, Teh-Ming; Hsu, Chia-Chi

    2009-12-01

    Excessive noise in nurseries has been found to cause adverse effects in infants, especially preterm infants in neonatal intensive care units (NICUs). The NICU design may influence the background sound level. We compared the sound level in two differently designed spaces in one NICU. We hypothesized that the sound level in an enclosed space would be quieter than in an open space. Sound levels were measured continuously 24 hours a day in two separate spaces at the same time, one enclosed and one open. Sound-level meters were placed near beds in each room. Sound levels were expressed as decibels, A-weighted (dBA) and presented as hourly L(eq), L(max), L(10), and L(90). The hourly L(eq) in the open space (50.8-57.2dB) was greater than that of the enclosed space (45.9-51.7dB), with a difference of 0.4-10.4dB, and a mean difference of 4.5dB (p<0.0001). The hourly L(10), L(90), and L(max) in the open space also exceeded that in the enclosed space (p<0.0001). The sound level measured in the enclosed space was quieter than in the open space. The design of bed space should be taken into consideration when building a new NICU. Besides the design of NICU architecture, continuous monitoring of sound level in the NICU is important to maintain a quiet environment.

  9. Development of Prediction Tool for Sound Absorption and Sound Insulation for Sound Proof Properties

    OpenAIRE

    Yoshio Kurosawa; Takao Yamaguchi

    2015-01-01

    High frequency automotive interior noise above 500 Hz considerably affects automotive passenger comfort. To reduce this noise, sound insulation material is often laminated on body panels or interior trim panels. For a more effective noise reduction, the sound reduction properties of this laminated structure need to be estimated. We have developed a new calculate tool that can roughly calculate the sound absorption and insulation properties of laminate structure and handy ...

  10. Parameterizing Sound: Design Considerations for an Environmental Sound Database

    Science.gov (United States)

    2015-04-01

    associated with, or produced by, a physical event or human activity and 2) sound sources that are common in the environment. Reproductions or sound...Rogers S. Confrontation naming of environmental sounds. Journal of Clinical and Experimental Neuropsychology . 2000;22(6):830–864. 14 VanDerveer NJ

  11. Estimation of the site of wheezes in pulmonary emphysema: airflow simulation study by the use of A 4D lung model.

    Science.gov (United States)

    Kitaoka, Hiroko; Cok, Salim

    2013-01-01

    Adventitious lung sounds in pulmonary emphysema, wheezes, are continuous musical sounds during expiration with 400 Hz or more. The textbook tells that expiratory airflow limitation in emphysema occurs at the peripheral airways and that wheezes are generated there. We have recently proposed a novel hypothesis based on image analysis and theoretical consideration that expiratory airflow limitation in emphysema occurs at the intra-mediastinal airway (trachea, main bronchi, and right lobar bronchi) due to compression by overinflated lungs. We performed expiratory airflow simulation by the use of a 4D finite element lung model, and found periodical vortex release with 300-900 Hz at the end of protrusion of the the tracheal posterior wall. Relationship between the peak frequency of pressure fluctuation and airflow velocity was in agreement with Strahal's law either in normal or emphysematous condition. Contrarily, airflow simulation in a small bronchus (1.5 mm in diameter) indicated no apparent periodic vortex release.

  12. Making fictions sound real - On film sound, perceptual realism and genre

    Directory of Open Access Journals (Sweden)

    Birger Langkjær

    2010-05-01

    Full Text Available This article examines the role that sound plays in making fictions perceptually real to film audiences, whether these fictions are realist or non-realist in content and narrative form. I will argue that some aspects of film sound practices and the kind of experiences they trigger are related to basic rules of human perception, whereas others are more properly explained in relation to how aesthetic devices, including sound, are used to characterise the fiction and thereby make it perceptually real to its audience. Finally, I will argue that not all genres can be defined by a simple taxonomy of sounds. Apart from an account of the kinds of sounds that typically appear in a specific genre, a genre analysis of sound may also benefit from a functionalist approach that focuses on how sounds can make both realist and non-realist aspects of genres sound real to audiences.

  13. Making fictions sound real - On film sound, perceptual realism and genre

    Directory of Open Access Journals (Sweden)

    Birger Langkjær

    2009-09-01

    Full Text Available This article examines the role that sound plays in making fictions perceptually real to film audiences, whether these fictions are realist or non-realist in content and narrative form. I will argue that some aspects of film sound practices and the kind of experiences they trigger are related to basic rules of human perception, whereas others are more properly explained in relation to how aesthetic devices, including sound, are used to characterise the fiction and thereby make it perceptually real to its audience. Finally, I will argue that not all genres can be defined by a simple taxonomy of sounds. Apart from an account of the kinds of sounds that typically appear in a specific genre, a genre analysis of sound may also benefit from a functionalist approach that focuses on how sounds can make both realist and non-realist aspects of genres sound real to audiences.

  14. In vivo breast sound-speed imaging with ultrasound tomography

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTITUTE; Duric, Neb [KARMANOS CANCER INSTITUTE; Littrup, Peter [KARMONOS CANCER INSTITUTE

    2009-01-01

    We discuss a bent-ray ultrasound tomography algorithm with total-variation (TV) regularization. We have applied this algorithm to 61 in vivo breast datasets collected with our in-house clinical prototype for imaging sound-speed distributions in the breast. Our analysis showed that TV regularization could preserve sharper lesion edges than the classic Tikhonov regularization. Furthermore, the image quality of our TV bent-ray sound-speed tomograms was superior to that of the straight-ray counterparts for all types of breasts within BI-RADS density categories 1-4. For all four breast types from fatty to dense, the improvements for average sharpness (in the unit of (m{center_dot} s) {sup -1}) of lesion edges in our TV bent-ray tomograms are between 2.1 to 3.4 fold compared to the straight ray tomograms. Reconstructed sound-speed tomograms illustrated that our algorithm could successfully image fatty and glandular tissues within the breast. We calculated the mean sound-speed values for fatty tissue and breast parenchyma as 1422 {+-} 9 mls (mean{+-} SD) and1487 {+-} 21 mls, respectively. Based on 32 lesions in a cohort of 61 patients, we also found that the mean sound-speed for malignant breast lesions (1548{+-}17 mls) was higher, on average, than that of benign ones (1513{+-}27 mls) (one-sided psound-speed tomograms can be used to assess breast density (, and therefore, breast cancer risk), as well as detect and help differentiate breast lesions. Finally, our sound-speed tomograms may also be a useful tool to monitor clinical response of breast cancer patients to neo-adjuvant chemotherapy.

  15. Lung pathology and exposure to radon daughters

    International Nuclear Information System (INIS)

    Saccomanno, G.

    1980-01-01

    The data presented suggest that the primary carcinogen of lung cancer in uranium miners is cigarette smoking because the incidence of lung cancer in noncigarette smokers is insignificant. In cigarette-smoking uranium miners, however, the incidence of cancer in those exposed to significant amounts of radon daughters is higher than in the smoking, nonmining population. This suggests that radon is an additive carcinogen if the lung has been injured by the cigarette-smoking carcinogen. Preliminary studies measuring DNA, T cells, and rosette inhibition immunological studies indicate closer monitoring of uranium miners' health during this occupation may be justified

  16. Sounds of space: listening to the Sun-Earth connection

    Science.gov (United States)

    Craig, N.; Mendez, B.; Luhmann, J.; Sircar, I.

    2003-04-01

    NASA's STEREO/IMPACT Mission includes an Education and Public Outreach component that seeks to offer national programs for broad audiences highlighting the mission's solar and geo-space research. In an effort to make observations of the Sun more accessible and exciting for a general audience, we look for alternative ways to represent the data. Scientists most often represent data visually in images, graphs, and movies. However, any data can also be represented as sound audible to the human ear, a process known as sonification. We will present our plans for an exciting prototype program that converts the science results of solar energetic particle data to sound. We plan to make sounds, imagery, and data available to the public through the World Wide Web where they may create their own sonifications, as well as integrate this effort to a science museum kiosk format. The kiosk station would include information on the STEREO mission and monitors showing images of the Sun from each of STEREO's two satellites. Our goal is to incorporate 3D goggles and a headset into the kiosk, allowing visitors to see the current or archived images in 3D and hear stereo sounds resulting from sonification of the corresponding data. Ultimately, we hope to collaborate with composers and create musical works inspired by these sounds and related solar images.

  17. Sound Absorbers

    Science.gov (United States)

    Fuchs, H. V.; Möser, M.

    Sound absorption indicates the transformation of sound energy into heat. It is, for instance, employed to design the acoustics in rooms. The noise emitted by machinery and plants shall be reduced before arriving at a workplace; auditoria such as lecture rooms or concert halls require a certain reverberation time. Such design goals are realised by installing absorbing components at the walls with well-defined absorption characteristics, which are adjusted for corresponding demands. Sound absorbers also play an important role in acoustic capsules, ducts and screens to avoid sound immission from noise intensive environments into the neighbourhood.

  18. Making Sound Connections

    Science.gov (United States)

    Deal, Walter F., III

    2007-01-01

    Sound provides and offers amazing insights into the world. Sound waves may be defined as mechanical energy that moves through air or other medium as a longitudinal wave and consists of pressure fluctuations. Humans and animals alike use sound as a means of communication and a tool for survival. Mammals, such as bats, use ultrasonic sound waves to…

  19. Artificial intelligence in diagnosis of obstructive lung disease: current status and future potential.

    Science.gov (United States)

    Das, Nilakash; Topalovic, Marko; Janssens, Wim

    2018-03-01

    The application of artificial intelligence in the diagnosis of obstructive lung diseases is an exciting phenomenon. Artificial intelligence algorithms work by finding patterns in data obtained from diagnostic tests, which can be used to predict clinical outcomes or to detect obstructive phenotypes. The purpose of this review is to describe the latest trends and to discuss the future potential of artificial intelligence in the diagnosis of obstructive lung diseases. Machine learning has been successfully used in automated interpretation of pulmonary function tests for differential diagnosis of obstructive lung diseases. Deep learning models such as convolutional neural network are state-of-the art for obstructive pattern recognition in computed tomography. Machine learning has also been applied in other diagnostic approaches such as forced oscillation test, breath analysis, lung sound analysis and telemedicine with promising results in small-scale studies. Overall, the application of artificial intelligence has produced encouraging results in the diagnosis of obstructive lung diseases. However, large-scale studies are still required to validate current findings and to boost its adoption by the medical community.

  20. Description of nighttime cough epochs in patients with stable COPD GOLD II-IV.

    Science.gov (United States)

    Fischer, Patrick; Gross, Volker; Kroenig, Johannes; Weissflog, Andreas; Hildebrandt, Olaf; Sohrabi, Keywan; Koehler, Ulrich

    Chronic cough is one of the main symptoms of COPD. Ambulatory objective monitoring provides novel insights into the determinants and characteristics of nighttime cough in COPD. Nighttime cough was monitored objectively by LEOSound lung sound monitor in patients with stable COPD II-IV. In 30 patients, with 10 patients in each stage group, nighttime cough was analyzed for epoch frequency, epoch severity (epoch length and coughs per epoch), and pattern (productive or nonproductive). Cough was found in all patients ranging from 1 to 294 events over the recording period. In 29 patients, cough epochs were monitored, ranging from 1 to 75 epochs. The highest amount of cough epochs was found in patients with COPD stage III. Active smokers had significantly more productive cough epochs (61%) than nonsmokers (24%). We found a high rate of nighttime cough epochs in patients with COPD, especially in those in stage III. Productive cough was predominantly found in patients with persistent smoking. LEOSound lung sound monitor offers a practical and valuable opportunity to evaluate cough objectively.

  1. Personal sleep pattern visualization using sequence-based kernel self-organizing map on sound data.

    Science.gov (United States)

    Wu, Hongle; Kato, Takafumi; Yamada, Tomomi; Numao, Masayuki; Fukui, Ken-Ichi

    2017-07-01

    We propose a method to discover sleep patterns via clustering of sound events recorded during sleep. The proposed method extends the conventional self-organizing map algorithm by kernelization and sequence-based technologies to obtain a fine-grained map that visualizes the distribution and changes of sleep-related events. We introduced features widely applied in sound processing and popular kernel functions to the proposed method to evaluate and compare performance. The proposed method provides a new aspect of sleep monitoring because the results demonstrate that sound events can be directly correlated to an individual's sleep patterns. In addition, by visualizing the transition of cluster dynamics, sleep-related sound events were found to relate to the various stages of sleep. Therefore, these results empirically warrant future study into the assessment of personal sleep quality using sound data. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Abnormal sound detection device

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji.

    1995-01-01

    Only components synchronized with rotation of pumps are sampled from detected acoustic sounds, to judge the presence or absence of abnormality based on the magnitude of the synchronized components. A synchronized component sampling means can remove resonance sounds and other acoustic sounds generated at a synchronously with the rotation based on the knowledge that generated acoustic components in a normal state are a sort of resonance sounds and are not precisely synchronized with the number of rotation. On the other hand, abnormal sounds of a rotating body are often caused by compulsory force accompanying the rotation as a generation source, and the abnormal sounds can be detected by extracting only the rotation-synchronized components. Since components of normal acoustic sounds generated at present are discriminated from the detected sounds, reduction of the abnormal sounds due to a signal processing can be avoided and, as a result, abnormal sound detection sensitivity can be improved. Further, since it is adapted to discriminate the occurrence of the abnormal sound from the actually detected sounds, the other frequency components which are forecast but not generated actually are not removed, so that it is further effective for the improvement of detection sensitivity. (N.H.)

  3. Radiation exposure by monitors and effects of whistling sound on hearing at workplaces in TV and film production sectors

    International Nuclear Information System (INIS)

    Strasser, H.

    1988-01-01

    Information transmission by means of VDUs, spreading at present rapidly in office work and some branches of the industrial production, is not only an auxiliary means but the essential destination and objective of working activities in specific areas of the media sector. By the progression of the video technique a further concentration of VDT work and the increasing gravity of all advantages and disadvantages is to be expected in the film and TV sectors. The real radiation exposure of the technical staff involved in working with and at monitors and potential risks of hearing by whistling sounds sent out by these apparatuses are analysed and evaluated. Experiences in health hazards by radiation from VDUs in office work had to be adapted adequately to the specific working conditions at work places in film and TV productions. (orig./HP) [de

  4. Effects of Exposure to the Sound from Seismic Airguns on Pallid Sturgeon and Paddlefish.

    Directory of Open Access Journals (Sweden)

    Arthur N Popper

    Full Text Available This study examined the effects of exposure to a single acoustic pulse from a seismic airgun array on caged endangered pallid sturgeon (Scaphirhynchus albus and on paddlefish (Polyodon spathula in Lake Sakakawea (North Dakota, USA. The experiment was designed to detect the onset of physiological responses including minor to mortal injuries. Experimental fish were held in cages as close as 1 to 3 m from the guns where peak negative sound pressure levels (Peak- SPL reached 231 dB re 1 μPa (205 dB re 1 μPa2·s sound exposure level [SEL]. Additional cages were placed at greater distances in an attempt to develop a dose-response relationship. Treatment and control fish were then monitored for seven days, euthanized, and necropsied to determine injuries. Necropsy results indicated that the probability of delayed mortality associated with pulse pressure following the seven day monitoring period was the same for exposed and control fish of both species. Exposure to a single pulse from a small air gun array (10,160 cm3 was not lethal for pallid sturgeon and paddlefish. However, the risks from exposure to multiple sounds and to sound exposure levels that exceed those reported here remain to be examined.

  5. Lung function measurement in awake young children

    DEFF Research Database (Denmark)

    Bisgaard, H; Klug, B

    1995-01-01

    ) and transcutaneous measurements of oxygen tension (Ptc,O2) were compared with concomitant measurements of specific airway resistance (sRaw) and forced expiratory volume in one second (FEV1) by whole body plethysmography and spirometry, respectively, during methacholine challenge in 21 young children aged 4-6 yrs...... to methacholine in young children aged 4-6 yrs. This implies that ZIOS, Rint and Ptc,O2 provide convenient indices of changes in lung function. Their combined use will be useful for monitoring airway diseases of young children.......The aim of the study was to evaluate methods applicable in a clinical setting for monitoring of changes in lung function in awake young children. Impedance measurements by the impulse oscillation technique (ZIOS), respiratory resistance measurements by the interrupter technique (Rint...

  6. Sound Search Engine Concept

    DEFF Research Database (Denmark)

    2006-01-01

    Sound search is provided by the major search engines, however, indexing is text based, not sound based. We will establish a dedicated sound search services with based on sound feature indexing. The current demo shows the concept of the sound search engine. The first engine will be realased June...

  7. Residential ozone and lung function in the elderly

    DEFF Research Database (Denmark)

    Braeuner, Elvira V.; Karottki, Dorina Gabriela; Frederiksen, Marie

    2016-01-01

    elderly non-smokers. Indoor ozone was measured passively in homes, while urban background outdoor ozone was monitored continuously at a fixed monitoring station located on the roof of the 20-m high university H.C. Ørsteds campus building in a park area. Lung function was measured at baseline as well...

  8. The sound manifesto

    Science.gov (United States)

    O'Donnell, Michael J.; Bisnovatyi, Ilia

    2000-11-01

    Computing practice today depends on visual output to drive almost all user interaction. Other senses, such as audition, may be totally neglected, or used tangentially, or used in highly restricted specialized ways. We have excellent audio rendering through D-A conversion, but we lack rich general facilities for modeling and manipulating sound comparable in quality and flexibility to graphics. We need coordinated research in several disciplines to improve the use of sound as an interactive information channel. Incremental and separate improvements in synthesis, analysis, speech processing, audiology, acoustics, music, etc. will not alone produce the radical progress that we seek in sonic practice. We also need to create a new central topic of study in digital audio research. The new topic will assimilate the contributions of different disciplines on a common foundation. The key central concept that we lack is sound as a general-purpose information channel. We must investigate the structure of this information channel, which is driven by the cooperative development of auditory perception and physical sound production. Particular audible encodings, such as speech and music, illuminate sonic information by example, but they are no more sufficient for a characterization than typography is sufficient for characterization of visual information. To develop this new conceptual topic of sonic information structure, we need to integrate insights from a number of different disciplines that deal with sound. In particular, we need to coordinate central and foundational studies of the representational models of sound with specific applications that illuminate the good and bad qualities of these models. Each natural or artificial process that generates informative sound, and each perceptual mechanism that derives information from sound, will teach us something about the right structure to attribute to the sound itself. The new Sound topic will combine the work of computer

  9. Unsound Sound

    DEFF Research Database (Denmark)

    Knakkergaard, Martin

    2016-01-01

    This article discusses the change in premise that digitally produced sound brings about and how digital technologies more generally have changed our relationship to the musical artifact, not simply in degree but in kind. It demonstrates how our acoustical conceptions are thoroughly challenged...... by the digital production of sound and, by questioning the ontological basis for digital sound, turns our understanding of the core term substance upside down....

  10. Medical education of attention: A qualitative study of learning to listen to sound.

    Science.gov (United States)

    Harris, Anna; Flynn, Eleanor

    2017-01-01

    There has been little qualitative research examining how physical examination skills are learned, particularly the sensory and subjective aspects of learning. The authors set out to study how medical students are taught and learn the skills of listening to sound. As part of an ethnographic study in Melbourne, 15 semi-structured in-depth interviews were conducted with students and teachers as a way to reflect explicitly on their learning and teaching. From these interviews, we found that learning the skills of listening to lung sounds was frequently difficult for students, with many experiencing awkwardness, uncertainty, pressure, and intimidation. However not everyone found this process difficult. Often those who had studied music reported finding it easier to be attentive to the frequency and rhythm of body sounds and find ways to describe them. By incorporating, distinctively in medical education, theoretical insights into "attentiveness" from anthropology and science and technology studies, the article suggests that musical education provides medical students with skills in sensory awareness. Training the senses is a critical aspect of diagnosis that needs to be better addressed in medical education. Practical approaches for improving students' education of attention are proposed.

  11. Early Sound Symbolism for Vowel Sounds

    Directory of Open Access Journals (Sweden)

    Ferrinne Spector

    2013-06-01

    Full Text Available Children and adults consistently match some words (e.g., kiki to jagged shapes and other words (e.g., bouba to rounded shapes, providing evidence for non-arbitrary sound–shape mapping. In this study, we investigated the influence of vowels on sound–shape matching in toddlers, using four contrasting pairs of nonsense words differing in vowel sound (/i/ as in feet vs. /o/ as in boat and four rounded–jagged shape pairs. Crucially, we used reduplicated syllables (e.g., kiki vs. koko rather than confounding vowel sound with consonant context and syllable variability (e.g., kiki vs. bouba. Toddlers consistently matched words with /o/ to rounded shapes and words with /i/ to jagged shapes (p < 0.01. The results suggest that there may be naturally biased correspondences between vowel sound and shape.

  12. Sound Art and Spatial Practices: Situating Sound Installation Art Since 1958

    OpenAIRE

    Ouzounian, Gascia

    2008-01-01

    This dissertation examines the emergence and development ofsound installation art, an under-recognized tradition that hasdeveloped between music, architecture, and media art practicessince the late 1950s. Unlike many musical works, which are concernedwith organizing sounds in time, sound installations organize sounds inspace; they thus necessitate new theoretical and analytical modelsthat take into consideration the spatial situated-ness of sound. Existingdiscourses on “spatial sound” privile...

  13. Mapping saltwater intrusion in the Biscayne Aquifer, Miami-Dade County, Florida using transient electromagnetic sounding

    Science.gov (United States)

    Fitterman, David V.

    2014-01-01

    Saltwater intrusion in southern Florida poses a potential threat to the public drinking-water supply that is typically monitored using water samples and electromagnetic induction logs collected from a network of wells. Transient electromagnetic (TEM) soundings are a complementary addition to the monitoring program because of their ease of use, low cost, and ability to fill in data gaps between wells. TEM soundings have been used to map saltwater intrusion in the Biscayne aquifer over a large part of south Florida including eastern Miami-Dade County and the Everglades. These two areas are very different with one being urban and the other undeveloped. Each poses different conditions that affect data collection and data quality. In the developed areas, finding sites large enough to make soundings is difficult. The presence of underground pipes further restricts useable locations. Electromagnetic noise, which reduces data quality, is also an issue. In the Everglades, access to field sites is difficult and working in water-covered terrain is challenging. Nonetheless, TEM soundings are an effective tool for mapping saltwater intrusion. Direct estimates of water quality can be obtained from the inverted TEM data using a formation factor determined for the Biscayne aquifer. This formation factor is remarkably constant over Miami-Dade County owing to the uniformity of the aquifer and the absence of clay. Thirty-six TEM soundings were collected in the Model Land area of southeast Miami-Dade County to aid in calibration of a helicopter electromagnetic (HEM) survey. The soundings and HEM survey revealed an area of saltwater intrusion aligned with canals and drainage ditches along U.S. Highway 1 and the Card Sound Road. These canals and ditches likely reduced freshwater levels through unregulated drainage and provided pathways for seawater to flow at least 12.4 km inland.

  14. Sound a very short introduction

    CERN Document Server

    Goldsmith, Mike

    2015-01-01

    Sound is integral to how we experience the world, in the form of noise as well as music. But what is sound? What is the physical basis of pitch and harmony? And how are sound waves exploited in musical instruments? Sound: A Very Short Introduction looks at the science of sound and the behaviour of sound waves with their different frequencies. It also explores sound in different contexts, covering the audible and inaudible, sound underground and underwater, acoustic and electronic sound, and hearing in humans and animals. It concludes with the problem of sound out of place—noise and its reduction.

  15. Sound production in Japanese medaka (Oryzias latipes) and its alteration by exposure to aldicarb and copper sulfate.

    Science.gov (United States)

    Kang, Ik Joon; Qiu, Xuchun; Moroishi, Junya; Oshima, Yuji

    2017-08-01

    This study is the first to report sound production in Japanese medaka (Oryzias latipes). Sound production was affected by exposure to the carbamate insecticide (aldicarb) and heavy-metal compound (copper sulfate). Medaka were exposed at four concentrations (aldicarb: 0, 0.25, 0.5, and 1 mg L -1 ; copper sulfate: 0, 0.5, 1, and 2 mg L -1 ), and sound characteristics were monitored for 5 h after exposure. We observed constant average interpulse intervals (approx 0.2 s) in all test groups before exposure, and in the control groups throughout the experiment. The average interpulse interval became significantly longer during the recording periods after 50 min of exposure to aldicarb, and reached a length of more than 0.3 s during the recording periods after 120 min exposure. Most medaka fish stopped to produce sound after 50 min of exposure to copper sulfate at 1 and 2 mg L -1 , resulting in significantly declined number of sound pulses and pulse groups. Relative shortened interpulse intervals of sound were occasionally observed in medaka fish exposed to 0.5 mg L -1 copper sulfate. These alternations in sound characteristics due to toxicants exposure suggested that they might impair acoustic communication of medaka fish, which may be important for their reproduction and survival. Our results suggested that using acoustic changes of medaka has potential to monitor precipitate water pollutions, such as intentional poisoning or accidental leakage of industrial waste. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Cannabis Smoking in 2015: A Concern for Lung Health?

    Science.gov (United States)

    Biehl, Jason R; Burnham, Ellen L

    2015-09-01

    Recent legislative successes allowing expanded access to recreational and medicinal cannabis have been associated with its increased use by the public, despite continued debates regarding its safety within the medical and scientific communities. Despite legislative changes, cannabis is most commonly used by smoking, although alternatives to inhalation have also emerged. Moreover, the composition of commercially available cannabis has dramatically changed in recent years. Therefore, developing sound scientific information regarding its impact on lung health is imperative, particularly because published data conducted prior to widespread legalization are conflicting and inconclusive. In this commentary, we delineate major observations of epidemiologic investigations examining cannabis use and the potential associated development of airways disease and lung cancer to highlight gaps in pulmonary knowledge. Additionally, we review major histopathologic alterations related to smoked cannabis and define specific areas in animal models and human clinical translational investigations that could benefit from additional development. Given that cannabis has an ongoing classification as a schedule I medication, federal funding to support investigations of modern cannabis use in terms of medicinal efficacy and safety profile on lung health have been elusive. It is clear, however, that the effects of inhaled cannabis on lung health remain uncertain and given increasing use patterns, are worthy of further investigation.

  17. Intercomparison of JAERI Torso Phantom lung sets

    International Nuclear Information System (INIS)

    Kramer, Gary H.; Hauck, Barry M.

    2000-01-01

    During the course of an IAEA sponsored In Vivo intercomparison using the JAERI phantom the Human Monitoring Laboratory was able to intercompare thirteen lung sets made by three suppliers. One set consisted of sliced lungs with planar inserts containing different radionuclides. The others consisted of whole lung sets with the activity homogeneously distributed throughout the tissue substitute material. Radionuclides in the study were: natural uranium, 3% enriched uranium, 241 Am, 238 Pu, 239 Pu, 152 Eu, and 232 Th Except for the 241 Am (59.5 keV) and occasionally one of the 232 Th (209 keV) photopeaks, the lung sets that had radioactivity homogeneously distributed throughout the tissue equivalent lung tissue material showed good agreement. The 241 Am lung set gave a counting efficiency that appeared 25% too high for all overlay plate configurations. This was observed by other participants. It exemplifies that the manufacture of tissue substitute lung sets is still something of a black art. Despite all precautions, this lung set is either inhomogeneous or has had the wrong activity added. Heterogeneity can lead to an error in the activity estimate of a factor of three if the activity was severely localised due to improper mixing. A factor of 1.25, which appears to be the discrepancy, could easily be explained in this way. It will not be known for some time, however, what the true reason is as the participants are still waiting for the destructive analysis of this lung set to determine the 'true' activity. The sliced lungs ( 241 Am, 152 Eu, and U-nat) manufactured by the Human Monitoring Laboratory are in excellent agreement with the other lung sets. The advantages of sliced lung sets and planar sources are manifold. Activity can be distributed in a known and reproducible manner to mimic either a homogeneous or heterogeneous distribution in the lung. Short lived radionuclides can be used. Cost is much less than purchasing or manufacturing lung sets that have the

  18. Improved electrode positions for local impedance measurements in the lung-a simulation study.

    Science.gov (United States)

    Orschulik, Jakob; Petkau, Rudolf; Wartzek, Tobias; Hochhausen, Nadine; Czaplik, Michael; Leonhardt, Steffen; Teichmann, Daniel

    2016-12-01

    Impedance spectroscopy can be used to analyze the dielectric properties of various materials. In the biomedical domain, it is used as bioimpedance spectroscopy (BIS) to analyze the composition of body tissue. Being a non-invasive, real-time capable technique, it is a promising modality, especially in the field of lung monitoring. Unfortunately, up to now, BIS does not provide any regional lung information as the electrodes are usually placed in hand-to-hand or transthoracic configurations. Even though transthoracic electrode configurations are in general capable of monitoring the lung, no focusing to specific regions is achieved. In order to resolve this issue, we use a finite element model (FEM) of the human body to study the effect of different electrode configurations on measured BIS data. We present evaluation results and show suitable electrode configurations for eight lung regions. We show that, using these optimized configurations, BIS measurements can be focused to desired regions allowing local lung analysis.

  19. What is Sound?

    OpenAIRE

    Nelson, Peter

    2014-01-01

    What is sound? This question is posed in contradiction to the every-day understanding that sound is a phenomenon apart from us, to be heard, made, shaped and organised. Thinking through the history of computer music, and considering the current configuration of digital communi-cations, sound is reconfigured as a type of network. This network is envisaged as non-hierarchical, in keeping with currents of thought that refuse to prioritise the human in the world. The relationship of sound to musi...

  20. Propagation of sound

    DEFF Research Database (Denmark)

    Wahlberg, Magnus; Larsen, Ole Næsbye

    2017-01-01

    properties can be modified by sound absorption, refraction, and interference from multi paths caused by reflections.The path from the source to the receiver may be bent due to refraction. Besides geometrical attenuation, the ground effect and turbulence are the most important mechanisms to influence...... communication sounds for airborne acoustics and bottom and surface effects for underwater sounds. Refraction becomes very important close to shadow zones. For echolocation signals, geometric attenuation and sound absorption have the largest effects on the signals....

  1. Rearranged EML4-ALK fusion transcripts sequester in circulating blood platelets and enable blood-based crizotinib response monitoring in non-small-cell lung cancer

    Science.gov (United States)

    Nilsson, R. Jonas A.; Karachaliou, Niki; Berenguer, Jordi; Gimenez-Capitan, Ana; Schellen, Pepijn; Teixido, Cristina; Tannous, Jihane; Kuiper, Justine L.; Drees, Esther; Grabowska, Magda; van Keulen, Marte; Heideman, Danielle A.M.; Thunnissen, Erik; Dingemans, Anne-Marie C.; Viteri, Santiago; Tannous, Bakhos A.; Drozdowskyj, Ana; Rosell, Rafael; Smit, Egbert F.; Wurdinger, Thomas

    2016-01-01

    Purpose: Non-small-cell lung cancers harboring EML4-ALK rearrangements are sensitive to crizotinib. However, despite initial response, most patients will eventually relapse, and monitoring EML4-ALK rearrangements over the course of treatment may help identify these patients. However, challenges associated with serial tumor biopsies have highlighted the need for blood-based assays for the monitoring of biomarkers. Platelets can sequester RNA released by tumor cells and are thus an attractive source for the non-invasive assessment of biomarkers. Methods: EML4-ALK rearrangements were analyzed by RT-PCR in platelets and plasma isolated from blood obtained from 77 patients with non-small-cell lung cancer, 38 of whom had EML4-ALK-rearranged tumors. In a subset of 29 patients with EML4-ALK-rearranged tumors who were treated with crizotinib, EML4-ALK rearrangements in platelets were correlated with progression-free and overall survival. Results: RT-PCR demonstrated 65% sensitivity and 100% specificity for the detection of EML4-ALK rearrangements in platelets. In the subset of 29 patients treated with crizotinib, progression-free survival was 3.7 months for patients with EML4-ALK+ platelets and 16 months for those with EML4-ALK− platelets (hazard ratio, 3.5; P = 0.02). Monitoring of EML4-ALK rearrangements in the platelets of one patient over a period of 30 months revealed crizotinib resistance two months prior to radiographic disease progression. Conclusions: Platelets are a valuable source for the non-invasive detection of EML4-ALK rearrangements and may prove useful for predicting and monitoring outcome to crizotinib, thereby improving clinical decisions based on radiographic imaging alone. PMID:26544515

  2. Making fictions sound real

    DEFF Research Database (Denmark)

    Langkjær, Birger

    2010-01-01

    This article examines the role that sound plays in making fictions perceptually real to film audiences, whether these fictions are realist or non-realist in content and narrative form. I will argue that some aspects of film sound practices and the kind of experiences they trigger are related...... to basic rules of human perception, whereas others are more properly explained in relation to how aesthetic devices, including sound, are used to characterise the fiction and thereby make it perceptually real to its audience. Finally, I will argue that not all genres can be defined by a simple taxonomy...... of sounds. Apart from an account of the kinds of sounds that typically appear in a specific genre, a genre analysis of sound may also benefit from a functionalist approach that focuses on how sounds can make both realist and non-realist aspects of genres sound real to audiences....

  3. Sound sensitivity of neurons in rat hippocampus during performance of a sound-guided task

    Science.gov (United States)

    Vinnik, Ekaterina; Honey, Christian; Schnupp, Jan; Diamond, Mathew E.

    2012-01-01

    To investigate how hippocampal neurons encode sound stimuli, and the conjunction of sound stimuli with the animal's position in space, we recorded from neurons in the CA1 region of hippocampus in rats while they performed a sound discrimination task. Four different sounds were used, two associated with water reward on the right side of the animal and the other two with water reward on the left side. This allowed us to separate neuronal activity related to sound identity from activity related to response direction. To test the effect of spatial context on sound coding, we trained rats to carry out the task on two identical testing platforms at different locations in the same room. Twenty-one percent of the recorded neurons exhibited sensitivity to sound identity, as quantified by the difference in firing rate for the two sounds associated with the same response direction. Sensitivity to sound identity was often observed on only one of the two testing platforms, indicating an effect of spatial context on sensory responses. Forty-three percent of the neurons were sensitive to response direction, and the probability that any one neuron was sensitive to response direction was statistically independent from its sensitivity to sound identity. There was no significant coding for sound identity when the rats heard the same sounds outside the behavioral task. These results suggest that CA1 neurons encode sound stimuli, but only when those sounds are associated with actions. PMID:22219030

  4. On-site monitoring of plutonium workers

    International Nuclear Information System (INIS)

    Burns, P.A.; Richardson, C.K.; Paulka, S.

    1996-01-01

    Full text: As part of the Maralinga rehabilitation program it is necessary to implement a system of on-site monitoring for the workers in order to ensure that they do not exceed recommended dose limits. The main problem in the rehabilitation work is the inhalation of dusts which contain micron sized plutonium particles. Using the new ICRP lung model and available data derived from measurements on contaminated soils, the intake for a dose of 20 mSv was calculated to be 1200 Bq. Four methods are available for direct measurements on workers; nasal swabs, faecal analysis, urine analysis and lung monitoring. The first two techniques are sensitive but will give varying results depending of the time interval between exposure and sampling. They are also difficult to implement on a routine basis. For the second two techniques, the activity in the lungs and the activity excreted per day in the urine remain relatively constant for several years following an intake, making more accurate dose estimates possible. The ICRP lung model predicts deposition in the lung of the order of 5% of intake and urinary excretion models predict approximately 10 -5 of this will be excreted daily in the urine. Lung monitoring of workers will be performed routinely at Maralinga in a partly enclosed room constructed from 10cm of steel, using two 50 mm diameter germanium detectors shielded with lead collimators. The detectors will measure 241 Am, which has grown in following the decay of 241 Pu, and the minimum detectable activity will be 15 - 20 Bq depending on the chest thickness and chest wall thickness of the individual being measured. Urine will be collected routinely and selected samples will be measured. The minimum detectable activity will be 2001μBq of 239 Pu in a daily urine sample

  5. Memory for product sounds: the effect of sound and label type.

    Science.gov (United States)

    Ozcan, Elif; van Egmond, René

    2007-11-01

    The (mnemonic) interactions between auditory, visual, and the semantic systems have been investigated using structurally complex auditory stimuli (i.e., product sounds). Six types of product sounds (air, alarm, cyclic, impact, liquid, mechanical) that vary in spectral-temporal structure were presented in four label type conditions: self-generated text, text, image, and pictogram. A memory paradigm that incorporated free recall, recognition, and matching tasks was employed. The results for the sound type suggest that the amount of spectral-temporal structure in a sound can be indicative for memory performance. Findings related to label type suggest that 'self' creates a strong bias for the retrieval and the recognition of sounds that were self-labeled; the density and the complexity of the visual information (i.e., pictograms) hinders the memory performance ('visual' overshadowing effect); and image labeling has an additive effect on the recall and matching tasks (dual coding). Thus, the findings suggest that the memory performances for product sounds are task-dependent.

  6. 33 CFR 167.1702 - In Prince William Sound: Prince William Sound Traffic Separation Scheme.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false In Prince William Sound: Prince William Sound Traffic Separation Scheme. 167.1702 Section 167.1702 Navigation and Navigable Waters COAST....1702 In Prince William Sound: Prince William Sound Traffic Separation Scheme. The Prince William Sound...

  7. Sounds Exaggerate Visual Shape

    Science.gov (United States)

    Sweeny, Timothy D.; Guzman-Martinez, Emmanuel; Ortega, Laura; Grabowecky, Marcia; Suzuki, Satoru

    2012-01-01

    While perceiving speech, people see mouth shapes that are systematically associated with sounds. In particular, a vertically stretched mouth produces a /woo/ sound, whereas a horizontally stretched mouth produces a /wee/ sound. We demonstrate that hearing these speech sounds alters how we see aspect ratio, a basic visual feature that contributes…

  8. Pressure sound level measurements at an educational environment in Goiania, Goias, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Jhonatha J.L.; Nascimento, Eriberto O. do; Oliveira, Lucas N. de [Instituto Federal de Educação, Ciência e Tecnologia de Goiás (IFG), Goiânia, GO (Brazil); Caldas, Linda V. E., E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In this work, twenty five points located on the ground floor of the Federal Institute of Education, Science and Technology of Goias - IFG - Campus Goiania, were analyzed in morning periods of two Saturdays. The pressure sound levels were measured at internal and external environments during routine activities seeking to perform an environmental monitoring at this institution. The initial hypothesis was that an amusement park (Mutirama Park) was responsible for originating noise pollution in the institution, but the results showed, within the campus environment, sound pressure levels in accordance with the Municipal legislation of Goiania for all points. (author)

  9. Pressure sound level measurements at an educational environment in Goiania, Goias, Brazil

    International Nuclear Information System (INIS)

    Costa, Jhonatha J.L.; Nascimento, Eriberto O. do; Oliveira, Lucas N. de; Caldas, Linda V. E.

    2017-01-01

    In this work, twenty five points located on the ground floor of the Federal Institute of Education, Science and Technology of Goias - IFG - Campus Goiania, were analyzed in morning periods of two Saturdays. The pressure sound levels were measured at internal and external environments during routine activities seeking to perform an environmental monitoring at this institution. The initial hypothesis was that an amusement park (Mutirama Park) was responsible for originating noise pollution in the institution, but the results showed, within the campus environment, sound pressure levels in accordance with the Municipal legislation of Goiania for all points. (author)

  10. Seasonal distribution of Dall's porpoise in Prince William Sound, Alaska

    Science.gov (United States)

    Moran, John R.; O'Dell, Matthew B.; Arimitsu, Mayumi L.; Straley, Janice M.; Dickson, Danielle M. S.

    2018-01-01

    Dall's porpoise, Phocoenoides dalli, are a conspicuous predator in the Prince William Sound ecosystem, yet there has been little effort directed towards monitoring this species since the 1980s, prior to the Exxon Valdez oil spill. We used vessel-based surveys to examine the seasonal distribution of Dall's porpoise in the waters of Prince William Sound during eight years from 2007 to 2015. Over the course of 168 days and 15,653 km of survey effort, 921 Dall's porpoise were encountered in 210 groups. We estimate an encounter rate of 0.061 porpoise/km traveled or 1 porpoise encountered for every 16.5 km traveled. Dall's porpoise were found throughout the year in Prince William Sound, and used a wide range of habitats, including those not considered typical of the species, such as bays, shallow water, and nearshore waters. Dall's porpoise seasonally shifted their center of distribution from the western passages in fall to the bays of the eastern Sound in winter and spring. Dall's porpoises were widely dispersed throughout the Sound in summer. We identified potential Dall's porpoise habitat (depth, slope, and distance from shore) within Prince William Sound using generalized additive models (GAM). Dall's porpoise were found in deeper water during summer and in shallowest water during spring. We propose that their use of novel habitats is a function of reduced predation risk associated with the decline of their main predator, killer whales (Orcinus orca), following the Exxon Valdez oil spill, and the presence of overwintering and spawning Pacific herring (Clupea pallasii). While the size of the Dall's porpoise population within Prince William Sound remains unknown, our encounter rates were lower than those reported in the 1970s. Their high metabolic rate and ubiquitous presence makes them one of the more important, yet understudied, forage fish predators in the region.

  11. Sound Zones

    DEFF Research Database (Denmark)

    Møller, Martin Bo; Olsen, Martin

    2017-01-01

    Sound zones, i.e. spatially confined regions of individual audio content, can be created by appropriate filtering of the desired audio signals reproduced by an array of loudspeakers. The challenge of designing filters for sound zones is twofold: First, the filtered responses should generate...... an acoustic separation between the control regions. Secondly, the pre- and post-ringing as well as spectral deterioration introduced by the filters should be minimized. The tradeoff between acoustic separation and filter ringing is the focus of this paper. A weighted L2-norm penalty is introduced in the sound...

  12. Can road traffic mask sound from wind turbines? Response to wind turbine sound at different levels of road traffic sound

    International Nuclear Information System (INIS)

    Pedersen, Eja; Berg, Frits van den; Bakker, Roel; Bouma, Jelte

    2010-01-01

    Wind turbines are favoured in the switch-over to renewable energy. Suitable sites for further developments could be difficult to find as the sound emitted from the rotor blades calls for a sufficient distance to residents to avoid negative effects. The aim of this study was to explore if road traffic sound could mask wind turbine sound or, in contrast, increases annoyance due to wind turbine noise. Annoyance of road traffic and wind turbine noise was measured in the WINDFARMperception survey in the Netherlands in 2007 (n=725) and related to calculated levels of sound. The presence of road traffic sound did not in general decrease annoyance with wind turbine noise, except when levels of wind turbine sound were moderate (35-40 dB(A) Lden) and road traffic sound level exceeded that level with at least 20 dB(A). Annoyance with both noises was intercorrelated but this correlation was probably due to the influence of individual factors. Furthermore, visibility and attitude towards wind turbines were significantly related to noise annoyance of modern wind turbines. The results can be used for the selection of suitable sites, possibly favouring already noise exposed areas if wind turbine sound levels are sufficiently low.

  13. Computed tomography of the lung. A pattern approach. 2. ed.

    International Nuclear Information System (INIS)

    Verschakelen, Johny A.; Wever, Walter de

    2018-01-01

    Computed Tomography of the Lung: A Pattern Approach aims to enable the reader to recognize and understand the CT signs of lung diseases and diseases with pulmonary involvement as a sound basis for diagnosis. After an introductory chapter, basic anatomy and its relevance to the interpretation of CT appearances is discussed. Advice is then provided on how to approach a CT scan of the lungs, and the different distribution and appearance patterns of disease are described. Subsequent chapters focus on the nature of these patterns, identify which diseases give rise to them, and explain how to differentiate between the diseases. The concluding chapter presents a large number of typical and less typical cases that will help the reader to practice application of the knowledge gained from the earlier chapters. Since the first edition, the book has been adapted and updated, with the inclusion of many new figures and case studies. It will be an invaluable asset both for radiologists and pulmonologists in training and for more experienced specialists wishing to update their knowledge.

  14. Structure-borne sound structural vibrations and sound radiation at audio frequencies

    CERN Document Server

    Cremer, L; Petersson, Björn AT

    2005-01-01

    Structure-Borne Sound"" is a thorough introduction to structural vibrations with emphasis on audio frequencies and the associated radiation of sound. The book presents in-depth discussions of fundamental principles and basic problems, in order to enable the reader to understand and solve his own problems. It includes chapters dealing with measurement and generation of vibrations and sound, various types of structural wave motion, structural damping and its effects, impedances and vibration responses of the important types of structures, as well as with attenuation of vibrations, and sound radi

  15. Validity and reliability of acoustic analysis of respiratory sounds in infants

    Science.gov (United States)

    Elphick, H; Lancaster, G; Solis, A; Majumdar, A; Gupta, R; Smyth, R

    2004-01-01

    Objective: To investigate the validity and reliability of computerised acoustic analysis in the detection of abnormal respiratory noises in infants. Methods: Blinded, prospective comparison of acoustic analysis with stethoscope examination. Validity and reliability of acoustic analysis were assessed by calculating the degree of observer agreement using the κ statistic with 95% confidence intervals (CI). Results: 102 infants under 18 months were recruited. Convergent validity for agreement between stethoscope examination and acoustic analysis was poor for wheeze (κ = 0.07 (95% CI, –0.13 to 0.26)) and rattles (κ = 0.11 (–0.05 to 0.27)) and fair for crackles (κ = 0.36 (0.18 to 0.54)). Both the stethoscope and acoustic analysis distinguished well between sounds (discriminant validity). Agreement between observers for the presence of wheeze was poor for both stethoscope examination and acoustic analysis. Agreement for rattles was moderate for the stethoscope but poor for acoustic analysis. Agreement for crackles was moderate using both techniques. Within-observer reliability for all sounds using acoustic analysis was moderate to good. Conclusions: The stethoscope is unreliable for assessing respiratory sounds in infants. This has important implications for its use as a diagnostic tool for lung disorders in infants, and confirms that it cannot be used as a gold standard. Because of the unreliability of the stethoscope, the validity of acoustic analysis could not be demonstrated, although it could discriminate between sounds well and showed good within-observer reliability. For acoustic analysis, targeted training and the development of computerised pattern recognition systems may improve reliability so that it can be used in clinical practice. PMID:15499065

  16. InfoSound

    DEFF Research Database (Denmark)

    Sonnenwald, Diane H.; Gopinath, B.; Haberman, Gary O.

    1990-01-01

    The authors explore ways to enhance users' comprehension of complex applications using music and sound effects to present application-program events that are difficult to detect visually. A prototype system, Infosound, allows developers to create and store musical sequences and sound effects with...

  17. The Sound of Science

    Science.gov (United States)

    Merwade, Venkatesh; Eichinger, David; Harriger, Bradley; Doherty, Erin; Habben, Ryan

    2014-01-01

    While the science of sound can be taught by explaining the concept of sound waves and vibrations, the authors of this article focused their efforts on creating a more engaging way to teach the science of sound--through engineering design. In this article they share the experience of teaching sound to third graders through an engineering challenge…

  18. Image-derived biomarkers and multimodal imaging strategies for lung cancer management

    Energy Technology Data Exchange (ETDEWEB)

    Sauter, Alexander W. [Eberhard Karls University Tuebingen, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Eberhard Karls University Tuebingen, Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Schwenzer, Nina; Pfannenberg, Christina [Eberhard Karls University Tuebingen, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Divine, Mathew R.; Pichler, Bernd J. [Eberhard Karls University Tuebingen, Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany)

    2015-04-01

    Non-small-cell lung cancer is the most common type of lung cancer and one of the leading causes of cancer-related death worldwide. For this reason, advances in diagnosis and treatment are urgently needed. With the introduction of new, highly innovative hybrid imaging technologies such as PET/CT, staging and therapy response monitoring in lung cancer patients have substantially evolved. In this review, we discuss the role of FDG PET/CT in the management of lung cancer patients and the importance of new emerging imaging technologies and radiotracer developments on the path to personalized medicine. (orig.)

  19. Detecting regional lung properties using audio transfer functions of the respiratory system.

    Science.gov (United States)

    Mulligan, K; Adler, A; Goubran, R

    2009-01-01

    In this study, a novel instrument has been developed for measuring changes in the distribution of lung fluid the respiratory system. The instrument consists of a speaker that inputs a 0-4kHz White Gaussian Noise (WGN) signal into a patient's mouth and an array of 4 electronic stethoscopes, linked via a fully adjustable harness, used to recover signals on the chest surface. The software system for processing the data utilizes the principles of adaptive filtering in order to obtain a transfer function that represents the input-output relationship for the signal as the volume of fluid in the lungs is varied. A chest phantom model was constructed to simulate the behavior of fluid related diseases within the lungs through the injection of varying volumes of water. Tests from the phantom model were compared to healthy subjects. Results show the instrument can obtain similar transfer functions and sound propagation delays between both human and phantom chests.

  20. Effects of staff training and electronic event monitoring on long-term adherence to lung-protective ventilation recommendations.

    Science.gov (United States)

    Castellanos, Ixchel; Martin, Marcus; Kraus, Stefan; Bürkle, Thomas; Prokosch, Hans-Ulrich; Schüttler, Jürgen; Toddenroth, Dennis

    2018-02-01

    To investigate long-term effects of staff training and electronic clinical decision support (CDS) on adherence to lung-protective ventilation recommendations. In 2012, group instructions and workshops at two surgical intensive care units (ICUs) started, focusing on standardized protocols for mechanical ventilation and volutrauma prevention. Subsequently implemented CDS functions continuously monitor ventilation parameters, and from 2015 triggered graphical notifications when tidal volume (V T ) violated individual thresholds. To estimate the effects of these educational and technical interventions, we retrospectively analyzed nine years of V T records from routine care. As outcome measures, we calculated relative frequencies of settings that conform to recommendations, case-specific mean excess V T , and total ICU survival. Assessing 571,478 V T records from 10,241 ICU cases indicated that adherence during pressure-controlled ventilation improved significantly after both interventions; the share of conforming V T records increased from 61.6% to 83.0% and then 86.0%. Despite increasing case severity, ICU survival remained nearly constant over time. Staff training effectively improves adherence to lung-protective ventilation strategies. The observed CDS effect seemed less pronounced, although it can easily be adapted to new recommendations. Both interventions, which futures studies could deploy in combination, promise to improve the precision of mechanical ventilation. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Bayesian stock assessment of Pacific herring in Prince William Sound, Alaska.

    Science.gov (United States)

    Muradian, Melissa L; Branch, Trevor A; Moffitt, Steven D; Hulson, Peter-John F

    2017-01-01

    The Pacific herring (Clupea pallasii) population in Prince William Sound, Alaska crashed in 1993 and has yet to recover, affecting food web dynamics in the Sound and impacting Alaskan communities. To help researchers design and implement the most effective monitoring, management, and recovery programs, a Bayesian assessment of Prince William Sound herring was developed by reformulating the current model used by the Alaska Department of Fish and Game. The Bayesian model estimated pre-fishery spawning biomass of herring age-3 and older in 2013 to be a median of 19,410 mt (95% credibility interval 12,150-31,740 mt), with a 54% probability that biomass in 2013 was below the management limit used to regulate fisheries in Prince William Sound. The main advantages of the Bayesian model are that it can more objectively weight different datasets and provide estimates of uncertainty for model parameters and outputs, unlike the weighted sum-of-squares used in the original model. In addition, the revised model could be used to manage herring stocks with a decision rule that considers both stock status and the uncertainty in stock status.

  2. Bayesian stock assessment of Pacific herring in Prince William Sound, Alaska.

    Directory of Open Access Journals (Sweden)

    Melissa L Muradian

    Full Text Available The Pacific herring (Clupea pallasii population in Prince William Sound, Alaska crashed in 1993 and has yet to recover, affecting food web dynamics in the Sound and impacting Alaskan communities. To help researchers design and implement the most effective monitoring, management, and recovery programs, a Bayesian assessment of Prince William Sound herring was developed by reformulating the current model used by the Alaska Department of Fish and Game. The Bayesian model estimated pre-fishery spawning biomass of herring age-3 and older in 2013 to be a median of 19,410 mt (95% credibility interval 12,150-31,740 mt, with a 54% probability that biomass in 2013 was below the management limit used to regulate fisheries in Prince William Sound. The main advantages of the Bayesian model are that it can more objectively weight different datasets and provide estimates of uncertainty for model parameters and outputs, unlike the weighted sum-of-squares used in the original model. In addition, the revised model could be used to manage herring stocks with a decision rule that considers both stock status and the uncertainty in stock status.

  3. Indo-Pacific humpback dolphin occurrence north of Lantau Island, Hong Kong, based on year-round passive acoustic monitoring.

    Science.gov (United States)

    Munger, Lisa; Lammers, Marc O; Cifuentes, Mattie; Würsig, Bernd; Jefferson, Thomas A; Hung, Samuel K

    2016-10-01

    Long-term passive acoustic monitoring (PAM) was conducted to study Indo-Pacific humpback dolphins, Sousa chinensis, as part of environmental impact assessments for several major coastal development projects in Hong Kong waters north of Lantau Island. Ecological acoustic recorders obtained 2711 days of recording at 13 sites from December 2012 to December 2014. Humpback dolphin sounds were manually detected on more than half of days with recordings at 12 sites, 8 of which were within proposed reclamation areas. Dolphin detection rates were greatest at Lung Kwu Chau, with other high-occurrence locations northeast of the Hong Kong International Airport and within the Lung Kwu Tan and Siu Ho Wan regions. Dolphin detection rates were greatest in summer and autumn (June-November) and were significantly reduced in spring (March-May) compared to other times of year. Click detection rates were significantly higher at night than during daylight hours. These findings suggest high use of many of the proposed reclamation/development areas by humpback dolphins, particularly at night, and demonstrate the value of long-term PAM for documenting spatial and temporal patterns in dolphin occurrence to help inform management decisions.

  4. Lung diffusion of soluble radioaerosols in scleroderma

    International Nuclear Information System (INIS)

    Chopra, S.K.; Taplin, G.V.; Tashkin, D.P.; Elam, D.

    1978-01-01

    Diffusion rates of soluble radioaerosols of sodium pertechnetate (/sup 99m/TcO 4 ; mol. wt. 163) and diethylentriaminepentaacetate (/sup 99m/Tc-DTPA; mol. wt. 492) were determined in ten normal subjects and ten patients with scleroderma having lung involvement. Twenty millicuries (mCi) each of /sup 99m/TcO 4 and /sup 99m/Tc-DTPA in 5 ml saline were aerosolized and inhaled on two different days. Initial lung retention after three minutes of administration was approximately 2 mCi. Two regions of interest over each posterior lung field were monitored with a scintillation camera and data were stored on magnetic tape. Decreasing levels of radioactivity were plotted semilogarithmically and half time (T 1 / 2 ) removal rates were calculated

  5. Sound and speech detection and classification in a Health Smart Home.

    Science.gov (United States)

    Fleury, A; Noury, N; Vacher, M; Glasson, H; Seri, J F

    2008-01-01

    Improvements in medicine increase life expectancy in the world and create a new bottleneck at the entrance of specialized and equipped institutions. To allow elderly people to stay at home, researchers work on ways to monitor them in their own environment, with non-invasive sensors. To meet this goal, smart homes, equipped with lots of sensors, deliver information on the activities of the person and can help detect distress situations. In this paper, we present a global speech and sound recognition system that can be set-up in a flat. We placed eight microphones in the Health Smart Home of Grenoble (a real living flat of 47m(2)) and we automatically analyze and sort out the different sounds recorded in the flat and the speech uttered (to detect normal or distress french sentences). We introduce the methods for the sound and speech recognition, the post-processing of the data and finally the experimental results obtained in real conditions in the flat.

  6. Light and Sound

    CERN Document Server

    Karam, P Andrew

    2010-01-01

    Our world is largely defined by what we see and hear-but our uses for light and sound go far beyond simply seeing a photo or hearing a song. A concentrated beam of light, lasers are powerful tools used in industry, research, and medicine, as well as in everyday electronics like DVD and CD players. Ultrasound, sound emitted at a high frequency, helps create images of a developing baby, cleans teeth, and much more. Light and Sound teaches how light and sound work, how they are used in our day-to-day lives, and how they can be used to learn about the universe at large.

  7. The Textile Form of Sound

    DEFF Research Database (Denmark)

    Bendixen, Cecilie

    Sound is a part of architecture, and sound is complex. Upon this, sound is invisible. How is it then possible to design visual objects that interact with the sound? This paper addresses the problem of how to get access to the complexity of sound and how to make textile material revealing the form...... goemetry by analysing the sound pattern at a specific spot. This analysis is done theoretically with algorithmic systems and practical with waves in water. The paper describes the experiments and the findings, and explains how an analysis of sound can be catched in a textile form....

  8. Fungal infections of the lung in children

    Energy Technology Data Exchange (ETDEWEB)

    Toma, Paolo; Colafati, Giovanna Stefania; D' Andrea, Maria Luisa [IRCCS Bambino Gesu Children' s Hospital, Department of Imaging, Rome (Italy); Bertaina, Alice; Mastronuzzi, Angela [IRCCS Bambino Gesu Children' s Hospital, Department of Pediatric Hematology/Oncology and Transfusion Medicine, Rome (Italy); Castagnola, Elio [IRCCS Istituto Giannina Gaslini, Department of Infective Diseases, Genoa (Italy); Finocchi, Andrea [IRCCS Bambino Gesu Children' s Hospital, Department of Pediatrics, Rome (Italy); Lucidi, Vincenzina [IRCCS Bambino Gesu Children' s Hospital, Cystic Fibrosis Center, Rome (Italy); Granata, Claudio [IRCCS Istituto Giannina Gaslini, Department of Pediatric Radiology, Genoa (Italy)

    2016-12-15

    Fungal infections of the lungs are relatively common and potentially life-threatening conditions in immunocompromised children. The role of imaging in children with lung mycosis is to delineate the extension of pulmonary involvement, to assess response to therapy, and to monitor for adverse sequelae such as bronchiectasis and cavitation. The aim of this paper is to show imaging findings in a series of patients with fungal pneumonia from two tertiary children's hospitals, to discuss differential diagnoses and to show how imaging findings can vary depending on the host immune response. (orig.)

  9. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2008-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  10. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2010-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  11. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2007-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  12. The 2011 marine heat wave in Cockburn Sound, southwest Australia

    Directory of Open Access Journals (Sweden)

    T. H. Rose

    2012-07-01

    Full Text Available Over 2000 km of Western Australian coastline experienced a significant marine heat wave in February and March 2011. Seawater temperature anomalies of +2–4 °C were recorded at a number of locations, and satellite-derived SSTs (sea surface temperatures were the highest on record. Here, we present seawater temperatures from southwestern Australia and describe, in detail, the marine climatology of Cockburn Sound, a large, multiple-use coastal embayment. We compared temperature and dissolved oxygen levels in 2011 with data from routine monitoring conducted from 2002–2010. A significant warming event, 2–4 °C in magnitude, persisted for > 8 weeks, and seawater temperatures at 10 to 20 m depth were significantly higher than those recorded in the previous 9 yr. Dissolved oxygen levels were depressed at most monitoring sites, being ~ 2 mg l−1 lower than usual in early March 2011. Ecological responses to short-term extreme events are poorly understood, but evidence from elsewhere along the Western Australian coastline suggests that the heat wave was associated with high rates of coral bleaching; fish, invertebrate and macroalgae mortalities; and algal blooms. However, there is a paucity of historical information on ecologically-sensitive habitats and taxa in Cockburn Sound, so that formal examinations of biological responses to the heat wave were not possible. The 2011 heat wave provided insights into conditions that may become more prevalent in Cockburn Sound, and elsewhere, if the intensity and frequency of short-term extreme events increases as predicted.

  13. NASA Space Sounds API

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA has released a series of space sounds via sound cloud. We have abstracted away some of the hassle in accessing these sounds, so that developers can play with...

  14. Acoustic system for pipe rupture monitoring and leak detection

    International Nuclear Information System (INIS)

    Herzog, W.; Jonas, H.

    1982-06-01

    As a safety aspect pipe rupture and leakage effects are of particular interest in nuclear power plants where severe consequences for the reactor may result. Counter measures against postulated pipe breaks and leakages in nuclear power plants are necessary whenever the main safety goals: safe shut-down, safe afterheat removal and retention of radioactivity, are endangered. The requirements to be met by a leak detection system depend on the time available for counter actions. If this time is short so that automatic actions are necessary the German safety criteria for nuclear power plants (Criterion 6.1) require two physically diverse signals to be monitored. One fairly obvious possibility of leak detection is to monitor process parameters (pressure, flow). As a diverse signal physical parameters outside the process may be employed: pressure transients temperature, humidity are principally suitable. In practical application, however, it is difficult to predict these parameters by way of calculation in order to establish the required set-point of the monitoring system. Experimental determination is possible only in special cases. A study of several ways of diverse leak detection methods leads to the very promising acoustic method. We investigated experimentally the feasibility of monitoring the sound created by a leakage. Air borne sound as well as body borne sound was analyzed

  15. The Study of Lung Cancer Personalized Medicine Through Circulating Cell Free DNA Test

    DEFF Research Database (Denmark)

    Ye, Mingzhi

    According to the serious situation of lung cancer in Chinese cancer incidence and mortality, better prognosis and early diagnosis are the key problems. These works are around of lung cancer genetic profiling, pathway signaling and tumor evolution, targeted therapy and transplant monitoring, and f...

  16. CompuLung: a multimedia CBL on pulmonary auscultation.

    Science.gov (United States)

    Mangione, S.; Dennis, S.

    1992-01-01

    Cardio-pulmonary auscultation, a time honored art, is suffering a declining interest caused by competing diagnostic technology and inadequate training of physicians. Overreliance on diagnostic technology is expensive, not cost-effective and bound to lead to loss of our clinical heritage. We need novel methods to teach and revive this art. Computer-Based Learning (CBL), particularly multimedia supporting graphics plus sound-and-motion pictures, appears to be ideally suited for teaching and sharpening this skill. We present in this paper a multimedia CBL ("CompuLung"), that provides the user with a comprehensive and interactive tutorial on pulmonary auscultation. PMID:1482999

  17. Intersections of lung progenitor cells, lung disease and lung cancer.

    Science.gov (United States)

    Kim, Carla F

    2017-06-30

    The use of stem cell biology approaches to study adult lung progenitor cells and lung cancer has brought a variety of new techniques to the field of lung biology and has elucidated new pathways that may be therapeutic targets in lung cancer. Recent results have begun to identify the ways in which different cell populations interact to regulate progenitor activity, and this has implications for the interventions that are possible in cancer and in a variety of lung diseases. Today's better understanding of the mechanisms that regulate lung progenitor cell self-renewal and differentiation, including understanding how multiple epigenetic factors affect lung injury repair, holds the promise for future better treatments for lung cancer and for optimising the response to therapy in lung cancer. Working between platforms in sophisticated organoid culture techniques, genetically engineered mouse models of injury and cancer, and human cell lines and specimens, lung progenitor cell studies can begin with basic biology, progress to translational research and finally lead to the beginnings of clinical trials. Copyright ©ERS 2017.

  18. Intersections of lung progenitor cells, lung disease and lung cancer

    Directory of Open Access Journals (Sweden)

    Carla F. Kim

    2017-06-01

    Full Text Available The use of stem cell biology approaches to study adult lung progenitor cells and lung cancer has brought a variety of new techniques to the field of lung biology and has elucidated new pathways that may be therapeutic targets in lung cancer. Recent results have begun to identify the ways in which different cell populations interact to regulate progenitor activity, and this has implications for the interventions that are possible in cancer and in a variety of lung diseases. Today's better understanding of the mechanisms that regulate lung progenitor cell self-renewal and differentiation, including understanding how multiple epigenetic factors affect lung injury repair, holds the promise for future better treatments for lung cancer and for optimising the response to therapy in lung cancer. Working between platforms in sophisticated organoid culture techniques, genetically engineered mouse models of injury and cancer, and human cell lines and specimens, lung progenitor cell studies can begin with basic biology, progress to translational research and finally lead to the beginnings of clinical trials.

  19. Sound Insulation between Dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2011-01-01

    Regulatory sound insulation requirements for dwellings exist in more than 30 countries in Europe. In some countries, requirements have existed since the 1950s. Findings from comparative studies show that sound insulation descriptors and requirements represent a high degree of diversity...... and initiate – where needed – improvement of sound insulation of new and existing dwellings in Europe to the benefit of the inhabitants and the society. A European COST Action TU0901 "Integrating and Harmonizing Sound Insulation Aspects in Sustainable Urban Housing Constructions", has been established and runs...... 2009-2013. The main objectives of TU0901 are to prepare proposals for harmonized sound insulation descriptors and for a European sound classification scheme with a number of quality classes for dwellings. Findings from the studies provide input for the discussions in COST TU0901. Data collected from 24...

  20. Remembering that big things sound big: Sound symbolism and associative memory.

    Science.gov (United States)

    Preziosi, Melissa A; Coane, Jennifer H

    2017-01-01

    According to sound symbolism theory, individual sounds or clusters of sounds can convey meaning. To examine the role of sound symbolic effects on processing and memory for nonwords, we developed a novel set of 100 nonwords to convey largeness (nonwords containing plosive consonants and back vowels) and smallness (nonwords containing fricative consonants and front vowels). In Experiments 1A and 1B, participants rated the size of the 100 nonwords and provided definitions to them as if they were products. Nonwords composed of fricative/front vowels were rated as smaller than those composed of plosive/back vowels. In Experiment 2, participants studied sound symbolic congruent and incongruent nonword and participant-generated definition pairings. Definitions paired with nonwords that matched the size and participant-generated meanings were recalled better than those that did not match. When the participant-generated definitions were re-paired with other nonwords, this mnemonic advantage was reduced, although still reliable. In a final free association study, the possibility that plosive/back vowel and fricative/front vowel nonwords elicit sound symbolic size effects due to mediation from word neighbors was ruled out. Together, these results suggest that definitions that are sound symbolically congruent with a nonword are more memorable than incongruent definition-nonword pairings. This work has implications for the creation of brand names and how to create brand names that not only convey desired product characteristics, but also are memorable for consumers.

  1. An Antropologist of Sound

    DEFF Research Database (Denmark)

    Groth, Sanne Krogh

    2015-01-01

    PROFESSOR PORTRAIT: Sanne Krogh Groth met Holger Schulze, newly appointed professor in Musicology at the Department for Arts and Cultural Studies, University of Copenhagen, to a talk about anthropology of sound, sound studies, musical canons and ideology.......PROFESSOR PORTRAIT: Sanne Krogh Groth met Holger Schulze, newly appointed professor in Musicology at the Department for Arts and Cultural Studies, University of Copenhagen, to a talk about anthropology of sound, sound studies, musical canons and ideology....

  2. Scintillation method possibilities for uranium detection in the lungs of a man

    International Nuclear Information System (INIS)

    Dolgirev, E.I.; Kajdanovskij, G.N.; Lossner, V.

    1978-01-01

    Detecting systems using various types of scintillation crystals were studied to find out whether it was possible to estimate the content of natural uranium in the lungs during lifetime. Data on the graduation of these systems obtained by use of an anthropomorphic phantom of the human trunk are given, as are values of minimal detectable levels of uranium in the lungs. A technique for a planned periodic monitoring of uranium in the lungs of every radiation worker is presented

  3. Migration patterns of post-spawning Pacific herring in a subarctic sound

    Science.gov (United States)

    Bishop, Mary Anne; Eiler, John H.

    2018-01-01

    Understanding the distribution of Pacific herring (Clupea pallasii) can be challenging because spawning, feeding and overwintering may take place in different areas separated by 1000s of kilometers. Along the northern Gulf of Alaska, Pacific herring movements after spring spawning are largely unknown. During the fall and spring, herring have been seen moving from the Gulf of Alaska into Prince William Sound, a large embayment, suggesting that fish spawning in the Sound migrate out into the Gulf of Alaska. We acoustic-tagged 69 adult herring on spawning grounds in Prince William Sound during April 2013 to determine seasonal migratory patterns. We monitored departures from the spawning grounds as well as herring arrivals and movements between the major entrances connecting Prince William Sound and the Gulf of Alaska. Departures of herring from the spawning grounds coincided with cessation of major spawning events in the immediate area. After spawning, 43 of 69 tagged herring (62%) moved to the entrances of Prince William Sound over a span of 104 d, although most fish arrived within 10 d of their departure from the spawning grounds. A large proportion remained in these areas until mid-June, most likely foraging on the seasonal bloom of large, Neocalanus copepods. Pulses of tagged herring detected during September and October at Montague Strait suggest that some herring returned from the Gulf of Alaska. Intermittent detections at Montague Strait and the Port Bainbridge passages from September through early January (when the transmitters expired) indicate that herring schools are highly mobile and are overwintering in this area. The pattern of detections at the entrances to Prince William Sound suggest that some herring remain in the Gulf of Alaska until late winter. The results of this study confirm the connectivity between local herring stocks in Prince William Sound and the Gulf of Alaska.

  4. Using sound to unmask losses disguised as wins in multiline slot machines.

    Science.gov (United States)

    Dixon, Mike J; Collins, Karen; Harrigan, Kevin A; Graydon, Candice; Fugelsang, Jonathan A

    2015-03-01

    Losses disguised as wins (LDWs) are slot machine outcomes where participants bet on multiple lines and win back less than their wager. Despite losing money, the machine celebrates these outcomes with reinforcing sights and sounds. Here, we sought to show that psychophysically and psychologically, participants treat LDWs as wins, but that we could expose LDWs as losses by using negative sounds as feedback. 157 participants were allocated into one of three conditions: a standard sound condition where LDWs, despite being losses, are paired with winning sights and sounds; a silent condition, where LDWs are paired with silence; and a negative sound condition where LDWs and regular losses are both followed by a negative sound. After viewing a paytable, participants conducted 300 spins on a slot machine simulator while heart rate deceleration (HRD) and skin conductance responses (SCRs) were monitored. Participants were then shown 20 different spin outcomes including LDWs and asked whether they had won or lost on that outcome. Participants then estimated on how many spins (out of 300) they won more than they wagered. SCRs were similar for losses and LDWs (both smaller than actual wins). HRD, however, was steeper for both wins and LDWs, compared to losses. In the standard condition, a majority of participants (mis)categorized LDWs as wins, and significantly overestimated the number of times they actually won. In the negative sound condition, this pattern was reversed; most participants correctly categorized LDWs as losses, and they gave high-fidelity win estimates. We conclude that participants both think and physiologically react to LDWs as though they are wins, a miscategorization that misleads them to think that they are winning more often than they actually are. Sound can be used to effectively prevent this misconception and unmask the disguise of LDWs.

  5. Lung clearance index to monitor treatment response in pulmonary exacerbations in preschool children with cystic fibrosis.

    Science.gov (United States)

    Rayment, Jonathan H; Stanojevic, Sanja; Davis, Stephanie D; Retsch-Bogart, George; Ratjen, Felix

    2018-05-01

    Antibiotic treatment for pulmonary symptoms in preschool children with cystic fibrosis (CF) varies among clinicians. The lung clearance index (LCI) is sensitive to early CF lung disease, but its utility to monitor pulmonary exacerbations in young children has not been assessed. We aim to (1) understand how LCI changes during lower respiratory tract symptoms relative to a recent clinically stable measurement, (2) determine whether LCI can identify antibiotic treatment response and (3) compare LCI changes to changes in spirometric indices. LCI and spirometry were measured at quarterly clinic visits over a 12-month period in preschool children with CF. Symptomatic visits were identified and classified as treated or untreated. Treatment response was estimated using propensity score matching methods. 104 symptomatic visits were identified in 78 participants. LCI increased from baseline in both treated (mean relative change +23.8% (95% CI 16.2 to 31.4)) and untreated symptomatic visits (mean relative change +11.2% (95% CI 2.4 to 19.9)). A significant antibiotic treatment effect was observed when LCI was used as the outcome measure (average treatment effect -15.5% (95% CI -25.4 to -5.6)) but not for z-score FEV 1 . LCI significantly deteriorated with pulmonary symptoms relative to baseline and improved with antibiotic treatment. These data suggest that LCI may have a role in the routine clinical care of preschool children with CF. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Lung surfactant levels are regulated by Ig-Hepta/GPR116 by monitoring surfactant protein D.

    Directory of Open Access Journals (Sweden)

    Taku Fukuzawa

    Full Text Available Lung surfactant is a complex mixture of lipids and proteins, which is secreted from the alveolar type II epithelial cell and coats the surface of alveoli as a thin layer. It plays a crucial role in the prevention of alveolar collapse through its ability to reduce surface tension. Under normal conditions, surfactant homeostasis is maintained by balancing its release and the uptake by the type II cell for recycling and the internalization by alveolar macrophages for degradation. Little is known about how the surfactant pool is monitored and regulated. Here we show, by an analysis of gene-targeted mice exhibiting massive accumulation of surfactant, that Ig-Hepta/GPR116, an orphan receptor, is expressed on the type II cell and sensing the amount of surfactant by monitoring one of its protein components, surfactant protein D, and its deletion results in a pulmonary alveolar proteinosis and emphysema-like pathology. By a coexpression experiment with Sp-D and the extracellular region of Ig-Hepta/GPR116 followed by immunoprecipitation, we identified Sp-D as the ligand of Ig-Hepta/GPR116. Analyses of surfactant metabolism in Ig-Hepta(+/+ and Ig-Hepta(-/- mice by using radioactive tracers indicated that the Ig-Hepta/GPR116 signaling system exerts attenuating effects on (i balanced synthesis of surfactant lipids and proteins and (ii surfactant secretion, and (iii a stimulating effect on recycling (uptake in response to elevated levels of Sp-D in alveolar space.

  7. An Intelligent Monitoring Network for Detection of Cracks in Anvils of High-Press Apparatus.

    Science.gov (United States)

    Tian, Hao; Yan, Zhaoli; Yang, Jun

    2018-04-09

    Due to the endurance of alternating high pressure and temperature, the carbide anvils of the high-press apparatus, which are widely used in the synthetic diamond industry, are prone to crack. In this paper, an acoustic method is used to monitor the crack events, and the intelligent monitoring network is proposed to classify the sound samples. The pulse sound signals produced by such cracking are first extracted based on a short-time energy threshold. Then, the signals are processed with the proposed intelligent monitoring network to identify the operation condition of the anvil of the high-pressure apparatus. The monitoring network is an improved convolutional neural network that solves the problems that may occur in practice. The length of pulse sound excited by the crack growth is variable, so a spatial pyramid pooling layer is adopted to solve the variable-length input problem. An adaptive weighted algorithm for loss function is proposed in this method to handle the class imbalance problem. The good performance regarding the accuracy and balance of the proposed intelligent monitoring network is validated through the experiments finally.

  8. Data from a national lung cancer registry contributes to improve outcome and quality of surgery: Danish results

    DEFF Research Database (Denmark)

    Jakobsen, Erik; Palshof, Torben; Østerlind, Kell

    2008-01-01

    OBJECTIVE: In 1998 The Danish Lung Cancer Group published the first edition of guidelines for diagnosis and treatment of lung cancer. A national registry was implemented in the year 2000 with the primary objective to monitor the implementation of these guidelines and nationwide to secure and impr......OBJECTIVE: In 1998 The Danish Lung Cancer Group published the first edition of guidelines for diagnosis and treatment of lung cancer. A national registry was implemented in the year 2000 with the primary objective to monitor the implementation of these guidelines and nationwide to secure...... has decreased from 23% to 11%. The proportion of patients having surgery within 14 days from referral has increased from 69% to 87%. CONCLUSIONS: Establishment of a national lung cancer group with the primary tasks to implement updated national guidelines and to secure valid registration of clinical...

  9. Detection of bronchial breathing caused by pneumonia.

    Science.gov (United States)

    Gross, V; Fachinger, P; Penzel, Th; Koehler, U; von Wichert, P; Vogelmeier, C

    2002-06-01

    The classic auscultation with stethoscope is the established clinical method for the detection of lung diseases. The interpretation of the sounds depends on the experience of the investigating physician. Therefore, a new computer-based method has been developed to classify breath sounds from digital lung sound recordings. Lung sounds of 11 patients with one-sided pneumonia and bronchial breathing were recorded on both the pneumonia side and on contralateral healthy side simultaneously using two microphones. The spectral power for the 300-600 Hz frequency band was computed for four respiratory cycles and normalized. For each breath, the ratio R between the time-segments (duration = 0.1 s) with the highest inspiratory and highest expiratory flow was calculated and averaged. We found significant differences in R between the pneumonia side (R = 1.4 +/- 1.3) and the healthy side (R = 0.5 +/- 0.5; p = 0.003 Wilcoxon-test) of lung. In 218 healthy volunteers we found R = 0.3 +/- 0.2 as a reference-value. The differences of ratio R (delta R) between the pneumonia side and the healthy side (delta R = 1.0 +/- 0.9) were significantly higher compared to follow-up studies after recovery (delta R = 0.0 +/- 0.1, p = 0.005 Wilcoxon-test). The computer based detection of bronchial breathing can be considered useful as part of a quantitative monitoring of patients at risk to develop pneumonia.

  10. Sound specificity effects in spoken word recognition: The effect of integrality between words and sounds

    DEFF Research Database (Denmark)

    Strori, Dorina; Zaar, Johannes; Cooke, Martin

    2017-01-01

    Recent evidence has shown that nonlinguistic sounds co-occurring with spoken words may be retained in memory and affect later retrieval of the words. This sound-specificity effect shares many characteristics with the classic voice-specificity effect. In this study, we argue that the sound......-specificity effect is conditional upon the context in which the word and sound coexist. Specifically, we argue that, besides co-occurrence, integrality between words and sounds is a crucial factor in the emergence of the effect. In two recognition-memory experiments, we compared the emergence of voice and sound...... from a mere co-occurrence context effect by removing the intensity modulation. The absence of integrality led to the disappearance of the sound-specificity effect. Taken together, the results suggest that the assimilation of background sounds into memory cannot be reduced to a simple context effect...

  11. Active sound reduction system and method

    NARCIS (Netherlands)

    2016-01-01

    The present invention refers to an active sound reduction system and method for attenuation of sound emitted by a primary sound source, especially for attenuation of snoring sounds emitted by a human being. This system comprises a primary sound source, at least one speaker as a secondary sound

  12. Acute effects of thoracic irradiation on lung function and structure in awake sheep

    International Nuclear Information System (INIS)

    Loyd, J.E.; Bolds, J.M.; Sheller, J.R.; Duke, S.S.; Gillette, A.W.; Malcolm, A.W.; Meyrick, B.O.; Brigham, K.L.

    1987-01-01

    To investigate the acute physiological and structural changes after lung irradiation, the effects of whole-lung irradiation were investigated in fourteen sheep. Ten sheep were prepared with vascular and chronic lung lymph catheters, then a week later were given 1,500 rad whole-lung radiation and monitored for 2 days. Four sheep were given the same dose of radiation and were killed 4 h later for structural studies. Lung lymph flow increased at 3 h after radiation (14.6 +/- 2.1 ml/h) to twice the base-line flow rate (7.5 +/- 1.3), with a high lymph-to-plasma protein concentration. Pulmonary arterial pressure increased twofold from base line (18 +/- 1.6 cmH2O) at 2 h after radiation (33 +/- 3.8). Cardiac output and systemic pressure in the aorta did not change after lung radiation. Arterial O 2 tension decreased from 85 +/- 3 to 59 +/- 4 Torr at 1 day after radiation. Lymphocyte counts in both blood and lung lymph decreased to a nadir by 4 h and remained low. Thromboxane B2 concentration in lung lymph increased from base line (0.07 +/- 0.03 ng/ml) to peak at 3 h after radiation (8.2 +/- 3.7 ng/ml). The structural studies showed numerous damaged lymphocytes in the peripheral lung and bronchial associated lymphoid tissue. Quantitative analysis of the number of granulocytes in peripheral lung showed no significant change (base line 6.2 +/- 0.8 granulocytes/100 alveoli, 4 h = 10.3 +/- 2.3). The most striking change involved lung airways. The epithelial lining of the majority of airways from intrapulmonary bronchus to respiratory bronchiolus revealed damage with the appearance of intracellular and intercellular cell fragments and granules. This new large animal model of acute radiation lung injury can be used to monitor physiological, biochemical, and morphological changes after lung radiation. It is relevant to the investigation of diffuse oxidant lung injury as well as to radiobiology per se

  13. [Lung protective ventilation - pathophysiology and diagnostics].

    Science.gov (United States)

    Uhlig, Stefan; Frerichs, Inéz

    2008-06-01

    Mechanical ventilation may lead to lung injury depending on the ventilatory settings (e.g. pressure amplitudes, endexpiratory pressures, frequency) and the length of mechanical ventilation. Particularly in the inhomogeneously injured lungs of ARDS patients, alveolar overextension results in volutrauma, cyclic opening and closure of alveolar units in atelectrauma. Particularly important appears to be the fact that these processes may also cause biotrauma, i.e. the ventilator-induced hyperactivation of inflammatory responses in the lung. These side effects are reduced, but not eliminated with the currently recommended ventilation strategy with a tidal volume of 6 ml/kg idealized body weight. It is our hope that in the future optimization of ventilator settings will be facilated by bedside monitoring of novel indices of respiratory mechanics such as the stress index or the Slice technique, and by innovative real-time imaging technologies such as electrical impedance tomography.

  14. Sound Symbolism in Basic Vocabulary

    Directory of Open Access Journals (Sweden)

    Søren Wichmann

    2010-04-01

    Full Text Available The relationship between meanings of words and their sound shapes is to a large extent arbitrary, but it is well known that languages exhibit sound symbolism effects violating arbitrariness. Evidence for sound symbolism is typically anecdotal, however. Here we present a systematic approach. Using a selection of basic vocabulary in nearly one half of the world’s languages we find commonalities among sound shapes for words referring to same concepts. These are interpreted as due to sound symbolism. Studying the effects of sound symbolism cross-linguistically is of key importance for the understanding of language evolution.

  15. Sounding the Alarm: An Introduction to Ecological Sound Art

    Directory of Open Access Journals (Sweden)

    Jonathan Gilmurray

    2016-12-01

    Full Text Available In recent years, a number of sound artists have begun engaging with ecological issues through their work, forming a growing movement of ˝ecological sound art˝. This paper traces its development, examines its influences, and provides examples of the artists whose work is currently defining this important and timely new field.

  16. Sound Stuff? Naïve materialism in middle-school students' conceptions of sound

    Science.gov (United States)

    Eshach, Haim; Schwartz, Judah L.

    2006-06-01

    Few studies have dealt with students’ preconceptions of sounds. The current research employs Reiner et al. (2000) substance schema to reveal new insights about students’ difficulties in understanding this fundamental topic. It aims not only to detect whether the substance schema is present in middle school students’ thinking, but also examines how students use the schema’s properties. It asks, moreover, whether the substance schema properties are used as islands of local consistency or whether one can identify more global coherent consistencies among the properties that the students use to explain the sound phenomena. In-depth standardized open-ended interviews were conducted with ten middle school students. Consistent with the substance schema, sound was perceived by our participants as being pushable, frictional, containable, or transitional. However, sound was also viewed as a substance different from the ordinary with respect to its stability, corpuscular nature, additive properties, and inertial characteristics. In other words, students’ conceptions of sound do not seem to fit Reiner et al.’s schema in all respects. Our results also indicate that students’ conceptualization of sound lack internal consistency. Analyzing our results with respect to local and global coherence, we found students’ conception of sound is close to diSessa’s “loosely connected, fragmented collection of ideas.” The notion that sound is perceived only as a “sort of a material,” we believe, requires some revision of the substance schema as it applies to sound. The article closes with a discussion concerning the implications of the results for instruction.

  17. Sound symbolism: the role of word sound in meaning.

    Science.gov (United States)

    Svantesson, Jan-Olof

    2017-09-01

    The question whether there is a natural connection between sound and meaning or if they are related only by convention has been debated since antiquity. In linguistics, it is usually taken for granted that 'the linguistic sign is arbitrary,' and exceptions like onomatopoeia have been regarded as marginal phenomena. However, it is becoming more and more clear that motivated relations between sound and meaning are more common and important than has been thought. There is now a large and rapidly growing literature on subjects as ideophones (or expressives), words that describe how a speaker perceives a situation with the senses, and phonaesthemes, units like English gl-, which occur in many words that share a meaning component (in this case 'light': gleam, glitter, etc.). Furthermore, psychological experiments have shown that sound symbolism in one language can be understood by speakers of other languages, suggesting that some kinds of sound symbolism are universal. WIREs Cogn Sci 2017, 8:e1441. doi: 10.1002/wcs.1441 For further resources related to this article, please visit the WIREs website. © 2017 Wiley Periodicals, Inc.

  18. Sound-by-sound thalamic stimulation modulates midbrain auditory excitability and relative binaural sensitivity in frogs.

    Science.gov (United States)

    Ponnath, Abhilash; Farris, Hamilton E

    2014-01-01

    Descending circuitry can modulate auditory processing, biasing sensitivity to particular stimulus parameters and locations. Using awake in vivo single unit recordings, this study tested whether electrical stimulation of the thalamus modulates auditory excitability and relative binaural sensitivity in neurons of the amphibian midbrain. In addition, by using electrical stimuli that were either longer than the acoustic stimuli (i.e., seconds) or presented on a sound-by-sound basis (ms), experiments addressed whether the form of modulation depended on the temporal structure of the electrical stimulus. Following long duration electrical stimulation (3-10 s of 20 Hz square pulses), excitability (spikes/acoustic stimulus) to free-field noise stimuli decreased by 32%, but returned over 600 s. In contrast, sound-by-sound electrical stimulation using a single 2 ms duration electrical pulse 25 ms before each noise stimulus caused faster and varied forms of modulation: modulation lasted sound-by-sound electrical stimulation varied between different acoustic stimuli, including for different male calls, suggesting modulation is specific to certain stimulus attributes. For binaural units, modulation depended on the ear of input, as sound-by-sound electrical stimulation preceding dichotic acoustic stimulation caused asymmetric modulatory effects: sensitivity shifted for sounds at only one ear, or by different relative amounts for both ears. This caused a change in the relative difference in binaural sensitivity. Thus, sound-by-sound electrical stimulation revealed fast and ear-specific (i.e., lateralized) auditory modulation that is potentially suited to shifts in auditory attention during sound segregation in the auditory scene.

  19. Sound specificity effects in spoken word recognition: The effect of integrality between words and sounds.

    Science.gov (United States)

    Strori, Dorina; Zaar, Johannes; Cooke, Martin; Mattys, Sven L

    2018-01-01

    Recent evidence has shown that nonlinguistic sounds co-occurring with spoken words may be retained in memory and affect later retrieval of the words. This sound-specificity effect shares many characteristics with the classic voice-specificity effect. In this study, we argue that the sound-specificity effect is conditional upon the context in which the word and sound coexist. Specifically, we argue that, besides co-occurrence, integrality between words and sounds is a crucial factor in the emergence of the effect. In two recognition-memory experiments, we compared the emergence of voice and sound specificity effects. In Experiment 1 , we examined two conditions where integrality is high. Namely, the classic voice-specificity effect (Exp. 1a) was compared with a condition in which the intensity envelope of a background sound was modulated along the intensity envelope of the accompanying spoken word (Exp. 1b). Results revealed a robust voice-specificity effect and, critically, a comparable sound-specificity effect: A change in the paired sound from exposure to test led to a decrease in word-recognition performance. In the second experiment, we sought to disentangle the contribution of integrality from a mere co-occurrence context effect by removing the intensity modulation. The absence of integrality led to the disappearance of the sound-specificity effect. Taken together, the results suggest that the assimilation of background sounds into memory cannot be reduced to a simple context effect. Rather, it is conditioned by the extent to which words and sounds are perceived as integral as opposed to distinct auditory objects.

  20. Analysis, Synthesis, and Perception of Musical Sounds The Sound of Music

    CERN Document Server

    Beauchamp, James W

    2007-01-01

    Analysis, Synthesis, and Perception of Musical Sounds contains a detailed treatment of basic methods for analysis and synthesis of musical sounds, including the phase vocoder method, the McAulay-Quatieri frequency-tracking method, the constant-Q transform, and methods for pitch tracking with several examples shown. Various aspects of musical sound spectra such as spectral envelope, spectral centroid, spectral flux, and spectral irregularity are defined and discussed. One chapter is devoted to the control and synthesis of spectral envelopes. Two advanced methods of analysis/synthesis are given: "Sines Plus Transients Plus Noise" and "Spectrotemporal Reassignment" are covered. Methods for timbre morphing are given. The last two chapters discuss the perception of musical sounds based on discrimination and multidimensional scaling timbre models.

  1. Michael Jackson's Sound Stages

    OpenAIRE

    Morten Michelsen

    2012-01-01

    In order to discuss analytically spatial aspects of recorded sound William Moylan’s concept of ‘sound stage’ is developed within a musicological framework as part of a sound paradigm which includes timbre, texture and sound stage. Two Michael Jackson songs (‘The Lady in My Life’ from 1982 and ‘Scream’ from 1995) are used to: a) demonstrate the value of such a conceptualisation, and b) demonstrate that the model has its limits, as record producers in the 1990s began ignoring the conventions of...

  2. Reversal to air-driven sound production revealed by a molecular phylogeny of tongueless frogs, family Pipidae

    Directory of Open Access Journals (Sweden)

    Glaw Frank

    2011-04-01

    Full Text Available Abstract Background Evolutionary novelties often appear by conferring completely new functions to pre-existing structures or by innovating the mechanism through which a particular function is performed. Sound production plays a central role in the behavior of frogs, which use their calls to delimit territories and attract mates. Therefore, frogs have evolved complex vocal structures capable of producing a wide variety of advertising sounds. It is generally acknowledged that most frogs call by moving an air column from the lungs through the glottis with the remarkable exception of the family Pipidae, whose members share a highly specialized sound production mechanism independent of air movement. Results Here, we performed behavioral observations in the poorly known African pipid genus Pseudhymenochirus and document that the sound production in this aquatic frog is almost certainly air-driven. However, morphological comparisons revealed an indisputable pipid nature of Pseudhymenochirus larynx. To place this paradoxical pattern into an evolutionary framework, we reconstructed robust molecular phylogenies of pipids based on complete mitochondrial genomes and nine nuclear protein-coding genes that coincided in placing Pseudhymenochirus nested among other pipids. Conclusions We conclude that although Pseudhymenochirus probably has evolved a reversal to the ancestral non-pipid condition of air-driven sound production, the mechanism through which it occurs is an evolutionary innovation based on the derived larynx of pipids. This strengthens the idea that evolutionary solutions to functional problems often emerge based on previous structures, and for this reason, innovations largely depend on possibilities and constraints predefined by the particular history of each lineage.

  3. Metal concentrations in homing pigeon lung tissue as a biomonitor of atmospheric pollution.

    Science.gov (United States)

    Cui, Jia; Halbrook, Richard S; Zang, Shuying; Han, Shuang; Li, Xinyu

    2018-03-01

    Atmospheric pollution in urban areas is a major worldwide concern with potential adverse impacts on wildlife and humans. Biomonitoring can provide direct evidence of the bioavailability and bioaccumulation of toxic metals in the environment that is not available with mechanical air monitoring. The current study continues our evaluation of the usefulness of homing pigeon lung tissue as a biomonitor of atmospheric pollution. Homing pigeons (1-2, 5-6, and 9-10+ year old (yo)) collected from Guangzhou during 2015 were necropsied and concentrations of cadmium (Cd), lead (Pb), and mercury (Hg) were measured in lung tissue. Lung Cd and Pb concentrations were significantly greater in 9-10+-year-old pigeons compared with those in other age groups, indicating their bioavailability and bioaccumulation. Lung Pb and Cd concentrations measured in 5-yo pigeons collected from Guangzhou during 2015 were significantly lower than concentrations reported in 5-yo homing pigeons collected from Guangzhou during 2011 and correlated with concentrations measured using mechanical air monitoring. In addition to temporal differences, spatial differences in concentrations of Cd, Pb, and Hg reported in ambient air samples and in pigeon lung tissues collected from Beijing and Guangzhou are discussed.

  4. ABOUT SOUNDS IN VIDEO GAMES

    Directory of Open Access Journals (Sweden)

    Denikin Anton A.

    2012-12-01

    Full Text Available The article considers the aesthetical and practical possibilities for sounds (sound design in video games and interactive applications. Outlines the key features of the game sound, such as simulation, representativeness, interactivity, immersion, randomization, and audio-visuality. The author defines the basic terminology in study of game audio, as well as identifies significant aesthetic differences between film sounds and sounds in video game projects. It is an attempt to determine the techniques of art analysis for the approaches in study of video games including aesthetics of their sounds. The article offers a range of research methods, considering the video game scoring as a contemporary creative practice.

  5. On-line Monitoring System Based on Principle of Electro-acoustic Monitoring for Transformer Partial Discharge

    Directory of Open Access Journals (Sweden)

    Guang Ya LIU

    2014-02-01

    Full Text Available Partial discharge inside a transformer is mainly responsible for the insulation aging and damage of the transformer. However, partial discharge is usually accompanied by external signals like sound, light and electrical signals and detectable physical phenomena such as characteristical gas and dielectric loss. Therefore, it is of great significance to monitor online the external signals and phenomena formed during partial discharge of the transformer when the transformer diagnoses faults. This paper gives a comprehensive overview of the electro-acoustic joint monitoring principles and its monitoring systems and the judgment skills concerned, on the basis of which the monitoring system is designed.

  6. Current and future molecular diagnostics in non-small-cell lung cancer.

    Science.gov (United States)

    Li, Chun Man; Chu, Wing Ying; Wong, Di Lun; Tsang, Hin Fung; Tsui, Nancy Bo Yin; Chan, Charles Ming Lok; Xue, Vivian Wei Wen; Siu, Parco Ming Fai; Yung, Benjamin Yat Ming; Chan, Lawrence Wing Chi; Wong, Sze Chuen Cesar

    2015-01-01

    The molecular investigation of lung cancer has opened up an advanced area for the diagnosis and therapeutic management of lung cancer patients. Gene alterations in cancer initiation and progression provide not only information on molecular changes in lung cancer but also opportunities in advanced therapeutic regime by personalized targeted therapy. EGFR mutations and ALK rearrangement are important predictive biomarkers for the efficiency of tyrosine kinase inhibitor treatment in lung cancer patients. Moreover, epigenetic aberration and microRNA dysregulation are recent advances in the early detection and monitoring of lung cancer. Although a wide range of molecular tests are available, standardization and validation of assay protocols are essential for the quality of the test outcome. In this review, current and new advancements of molecular biomarkers for non-small-cell lung cancer will be discussed. Recommendations on future development of molecular diagnostic services will also be explored.

  7. Advanced Machine learning Algorithm Application for Rotating Machine Health Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kanemoto, Shigeru; Watanabe, Masaya [The University of Aizu, Aizuwakamatsu (Japan); Yusa, Noritaka [Tohoku University, Sendai (Japan)

    2014-08-15

    The present paper tries to evaluate the applicability of conventional sound analysis techniques and modern machine learning algorithms to rotating machine health monitoring. These techniques include support vector machine, deep leaning neural network, etc. The inner ring defect and misalignment anomaly sound data measured by a rotating machine mockup test facility are used to verify the above various kinds of algorithms. Although we cannot find remarkable difference of anomaly discrimination performance, some methods give us the very interesting eigen patterns corresponding to normal and abnormal states. These results will be useful for future more sensitive and robust anomaly monitoring technology.

  8. Advanced Machine learning Algorithm Application for Rotating Machine Health Monitoring

    International Nuclear Information System (INIS)

    Kanemoto, Shigeru; Watanabe, Masaya; Yusa, Noritaka

    2014-01-01

    The present paper tries to evaluate the applicability of conventional sound analysis techniques and modern machine learning algorithms to rotating machine health monitoring. These techniques include support vector machine, deep leaning neural network, etc. The inner ring defect and misalignment anomaly sound data measured by a rotating machine mockup test facility are used to verify the above various kinds of algorithms. Although we cannot find remarkable difference of anomaly discrimination performance, some methods give us the very interesting eigen patterns corresponding to normal and abnormal states. These results will be useful for future more sensitive and robust anomaly monitoring technology

  9. Sound [signal] noise

    DEFF Research Database (Denmark)

    Bjørnsten, Thomas

    2012-01-01

    The article discusses the intricate relationship between sound and signification through notions of noise. The emergence of new fields of sonic artistic practices has generated several questions of how to approach sound as aesthetic form and material. During the past decade an increased attention...... has been paid to, for instance, a category such as ‘sound art’ together with an equally strengthened interest in phenomena and concepts that fall outside the accepted aesthetic procedures and constructions of what we traditionally would term as musical sound – a recurring example being ‘noise’....

  10. Beneath sci-fi sound: primer, science fiction sound design, and American independent cinema

    OpenAIRE

    Johnston, Nessa

    2012-01-01

    Primer is a very low budget science-fiction film that deals with the subject of time travel; however, it looks and sounds quite distinctively different from other films associated with the genre. While Hollywood blockbuster sci-fi relies on “sound spectacle” as a key attraction, in contrast Primer sounds “lo-fi” and screen-centred, mixed to two channel stereo rather than the now industry-standard 5.1 surround sound. Although this is partly a consequence of the economics of its production, the...

  11. Alarm points for fixed oxygen monitors

    International Nuclear Information System (INIS)

    Miller, G.C.

    1987-05-01

    Oxygen concentration monitors were installed in a vault where numerous pipes carried inert cryogens and gases to the Mirror Fusion Test Facility (MFTF-B) experimental vessel at Lawrence Livermore National Laboratory (LLNL). The problems associated with oxygen-monitoring systems and the reasons why such monitors were installed were reviewed. As a result of this review, the MFTF-B monitors were set to sound an evacuation alarm when the oxygen concentration fell below 18%. We chose the 18% alarm criterion to minimize false alarms and to allow time for personnel to escape in an oxygen-deficient environment

  12. Variability of road traffic noise recorded by stationary monitoring stations

    Science.gov (United States)

    Bąkowski, Andrzej; Radziszewski, Leszek

    2017-11-01

    The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads out of the town in the direction of Kraków and Warszawa. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The coefficient of variation and positional variation were proposed for performing comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes. The differences concerned the values of coefficients of variation of the equivalent sound levels.

  13. TH-CD-207A-05: Lung Surface Deformation Vector Fields Prediction by Monitoring Respiratory Surrogate Signals

    International Nuclear Information System (INIS)

    Nasehi Tehrani, J; Wang, J; McEwan, A

    2016-01-01

    Purpose: In this study, we developed and evaluated a method for predicting lung surface deformation vector fields (SDVFs) based on surrogate signals such as chest and abdomen motion at selected locations and spirometry measurements. Methods: A Patient-specific 3D triangular surface mesh of the lung region at end-expiration (EE) phase was obtained by threshold-based segmentation method. For each patient, a spirometer recorded the flow volume changes of the lungs; and 192 selected points at a regular spacing of 2cm X 2cm matrix points over a total area of 34cm X 24cm on the surface of chest and abdomen was used to detect chest wall motions. Preprocessing techniques such as QR factorization with column pivoting (QRCP) were employed to remove redundant observations of the chest and abdominal area. To create a statistical model between the lung surface and the corresponding surrogate signals, we developed a predictive model based on canonical ridge regression (CRR). Two unique weighting vectors were selected for each vertex on the surface of the lung, and they were optimized during the training process using the all other phases of 4D-CT except the end-inspiration (EI) phase. These parameters were employed to predict the vertices locations of a testing data set, which was the EI phase of 4D-CT. Results: For ten lung cancer patients, the deformation vector field of each vertex of lung surface mesh was estimated from the external motion at selected positions on the chest wall surface plus spirometry measurements. The average estimation of 98th percentile of error was less than 1 mm (AP= 0.85, RL= 0.61, and SI= 0.82). Conclusion: The developed predictive model provides a non-invasive approach to derive lung boundary condition. Together with personalized biomechanical respiration modelling, the proposed model can be used to derive the lung tumor motion during radiation therapy accurately from non-invasive measurements.

  14. TH-CD-207A-05: Lung Surface Deformation Vector Fields Prediction by Monitoring Respiratory Surrogate Signals

    Energy Technology Data Exchange (ETDEWEB)

    Nasehi Tehrani, J; Wang, J [UT Southwestern Medical Center, Dallas, TX (United States); McEwan, A [The University of Sydney, Sydney, New South Wales (Australia)

    2016-06-15

    Purpose: In this study, we developed and evaluated a method for predicting lung surface deformation vector fields (SDVFs) based on surrogate signals such as chest and abdomen motion at selected locations and spirometry measurements. Methods: A Patient-specific 3D triangular surface mesh of the lung region at end-expiration (EE) phase was obtained by threshold-based segmentation method. For each patient, a spirometer recorded the flow volume changes of the lungs; and 192 selected points at a regular spacing of 2cm X 2cm matrix points over a total area of 34cm X 24cm on the surface of chest and abdomen was used to detect chest wall motions. Preprocessing techniques such as QR factorization with column pivoting (QRCP) were employed to remove redundant observations of the chest and abdominal area. To create a statistical model between the lung surface and the corresponding surrogate signals, we developed a predictive model based on canonical ridge regression (CRR). Two unique weighting vectors were selected for each vertex on the surface of the lung, and they were optimized during the training process using the all other phases of 4D-CT except the end-inspiration (EI) phase. These parameters were employed to predict the vertices locations of a testing data set, which was the EI phase of 4D-CT. Results: For ten lung cancer patients, the deformation vector field of each vertex of lung surface mesh was estimated from the external motion at selected positions on the chest wall surface plus spirometry measurements. The average estimation of 98th percentile of error was less than 1 mm (AP= 0.85, RL= 0.61, and SI= 0.82). Conclusion: The developed predictive model provides a non-invasive approach to derive lung boundary condition. Together with personalized biomechanical respiration modelling, the proposed model can be used to derive the lung tumor motion during radiation therapy accurately from non-invasive measurements.

  15. Sound absorption coefficient in situ: an alternative for estimating soil loss factors.

    Science.gov (United States)

    Freire, Rosane; Meletti de Abreu, Marco Henrique; Okada, Rafael Yuri; Soares, Paulo Fernando; GranhenTavares, Célia Regina

    2015-01-01

    The relationship between the sound absorption coefficient and factors of the Universal Soil Loss Equation (USLE) was determined in a section of the Maringá Stream basin, Paraná State, by using erosion plots. In the field, four erosion plots were built on a reduced scale, with dimensions of 2.0×12.5m. With respect to plot coverage, one was kept with bare soil and the others contained forage grass (Brachiaria), corn and wheat crops, respectively. Planting was performed without any type of conservation practice in an area with a 9% slope. A sedimentation tank was placed at the end of each plot to collect the material transported. For the acoustic system, pink noise was used in the measurement of the proposed monitoring, for collecting information on incident and reflected sound pressure levels. In general, obtained values of soil loss confirmed that 94.3% of material exported to the basin water came from the bare soil plot, 2.8% from the corn plot, 1.8% from the wheat plot, and 1.1% from the forage grass plot. With respect to the acoustic monitoring, results indicated that at 16kHz erosion plot coverage type had a significant influence on the sound absorption coefficient. High correlation coefficients were found in estimations of the A and C factors of the USLE, confirming that the acoustic technique is feasible for the determination of soil loss directly in the field. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Can mechanical ventilation strategies reduce chronic lung disease?

    Science.gov (United States)

    Donn, Steven M; Sinha, Sunil K

    2003-12-01

    Chronic lung disease (CLD) continues to be a significant complication in newborn infants undergoing mechanical ventilation for respiratory failure. Although the aetiology of CLD is multifactorial, specific factors related to mechanical ventilation, including barotrauma, volutrauma and atelectrauma, have been implicated as important aetiologic mechanisms. This article discusses the ways in which these factors might be manipulated by various mechanical ventilatory strategies to reduce ventilator-induced lung injury. These include continuous positive airway pressure, permissive hypercapnia, patient-triggered ventilation, volume-targeted ventilation, proportional assist ventilation, high-frequency ventilation and real-time monitoring.

  17. Sound classification of dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2012-01-01

    National schemes for sound classification of dwellings exist in more than ten countries in Europe, typically published as national standards. The schemes define quality classes reflecting different levels of acoustical comfort. Main criteria concern airborne and impact sound insulation between...... dwellings, facade sound insulation and installation noise. The schemes have been developed, implemented and revised gradually since the early 1990s. However, due to lack of coordination between countries, there are significant discrepancies, and new standards and revisions continue to increase the diversity...... is needed, and a European COST Action TU0901 "Integrating and Harmonizing Sound Insulation Aspects in Sustainable Urban Housing Constructions", has been established and runs 2009-2013, one of the main objectives being to prepare a proposal for a European sound classification scheme with a number of quality...

  18. Vocal Imitations of Non-Vocal Sounds

    Science.gov (United States)

    Houix, Olivier; Voisin, Frédéric; Misdariis, Nicolas; Susini, Patrick

    2016-01-01

    Imitative behaviors are widespread in humans, in particular whenever two persons communicate and interact. Several tokens of spoken languages (onomatopoeias, ideophones, and phonesthemes) also display different degrees of iconicity between the sound of a word and what it refers to. Thus, it probably comes at no surprise that human speakers use a lot of imitative vocalizations and gestures when they communicate about sounds, as sounds are notably difficult to describe. What is more surprising is that vocal imitations of non-vocal everyday sounds (e.g. the sound of a car passing by) are in practice very effective: listeners identify sounds better with vocal imitations than with verbal descriptions, despite the fact that vocal imitations are inaccurate reproductions of a sound created by a particular mechanical system (e.g. a car driving by) through a different system (the voice apparatus). The present study investigated the semantic representations evoked by vocal imitations of sounds by experimentally quantifying how well listeners could match sounds to category labels. The experiment used three different types of sounds: recordings of easily identifiable sounds (sounds of human actions and manufactured products), human vocal imitations, and computational “auditory sketches” (created by algorithmic computations). The results show that performance with the best vocal imitations was similar to the best auditory sketches for most categories of sounds, and even to the referent sounds themselves in some cases. More detailed analyses showed that the acoustic distance between a vocal imitation and a referent sound is not sufficient to account for such performance. Analyses suggested that instead of trying to reproduce the referent sound as accurately as vocally possible, vocal imitations focus on a few important features, which depend on each particular sound category. These results offer perspectives for understanding how human listeners store and access long

  19. The effects of drugs, other foreign compounds, and cigarette smoke on the synthesis of protein by lung slices

    International Nuclear Information System (INIS)

    Hellstern, K.; Curtis, C.G.; Powell, G.M.; Upshall, D.G.

    1990-01-01

    The incorporation of 14 C-leucine into rabbit lung slices was monitored in the absence and presence of selected drugs and chemicals relevant to the perturbation of lung function and the development of lung disease. Known inhibitors of protein synthesis (cycloheximide and ricin) inhibited the incorporation of 14 C-leucine. Marked inhibition was also recorded with the lung toxins paraquat and 4-ipomeanol. By contrast, orciprenaline, salbutamol, and terbutaline were without effect although some response was recorded with isoprenaline. The filtered gas phase of cigarette smoke and acrolein, one of its components, were inhibitory but protection was afforded by N-acetylcysteine. It is suggested that the inhibitory effects of cigarette smoke may be due to its acrolein content. It is further suggested that the use of lung slices and measurements of 14 C-leucine incorporation provide valuable means for monitoring potential pulmonary toxins

  20. Human Organotypic Lung Tumor Models: Suitable For Preclinical 18F-FDG PET-Imaging.

    Directory of Open Access Journals (Sweden)

    David Fecher

    Full Text Available Development of predictable in vitro tumor models is a challenging task due to the enormous complexity of tumors in vivo. The closer the resemblance of these models to human tumor characteristics, the more suitable they are for drug-development and -testing. In the present study, we generated a complex 3D lung tumor test system based on acellular rat lungs. A decellularization protocol was established preserving the architecture, important ECM components and the basement membrane of the lung. Human lung tumor cells cultured on the scaffold formed cluster and exhibited an up-regulation of the carcinoma-associated marker mucin1 as well as a reduced proliferation rate compared to respective 2D culture. Additionally, employing functional imaging with 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography (FDG-PET these tumor cell cluster could be detected and tracked over time. This approach allowed monitoring of a targeted tyrosine kinase inhibitor treatment in the in vitro lung tumor model non-destructively. Surprisingly, FDG-PET assessment of single tumor cell cluster on the same scaffold exhibited differences in their response to therapy, indicating heterogeneity in the lung tumor model. In conclusion, our complex lung tumor test system features important characteristics of tumors and its microenvironment and allows monitoring of tumor growth and -metabolism in combination with functional imaging. In longitudinal studies, new therapeutic approaches and their long-term effects can be evaluated to adapt treatment regimes in future.

  1. Urban Noise Recorded by Stationary Monitoring Stations

    Science.gov (United States)

    Bąkowski, Andrzej; Radziszewski, Leszek; Dekýš, Vladimir

    2017-10-01

    The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads in the town in the direction of Łódź and Lublin. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The agreement of the distribution of the variable under analysis with normal distribution was evaluated. It was demonstrated that in most cases (for both roads) there was sufficient evidence to reject the null hypothesis at the significance level of 0.05. It was noted that compared with Łódź Road, in the case of Lublin Road data, more cases were recorded for which the null hypothesis could not be rejected. Uncertainties of the equivalent sound level measurements were compared within the periods under analysis. The standard deviation, coefficient of variation, the positional coefficient of variation, the quartile deviation was proposed for performing a comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes and time intervals. The differences concerned the values of uncertainties and coefficients of variation of the equivalent sound levels.

  2. Assessment of the health effects of low-frequency sounds and infra-sounds from wind farms. ANSES Opinion. Collective expertise report

    International Nuclear Information System (INIS)

    Lepoutre, Philippe; Avan, Paul; Cheveigne, Alain de; Ecotiere, David; Evrard, Anne-Sophie; Hours, Martine; Lelong, Joel; Moati, Frederique; Michaud, David; Toppila, Esko; Beugnet, Laurent; Bounouh, Alexandre; Feltin, Nicolas; Campo, Pierre; Dore, Jean-Francois; Ducimetiere, Pierre; Douki, Thierry; Flahaut, Emmanuel; Gaffet, Eric; Lafaye, Murielle; Martinsons, Christophe; Mouneyrac, Catherine; Ndagijimana, Fabien; Soyez, Alain; Yardin, Catherine; Cadene, Anthony; Merckel, Olivier; Niaudet, Aurelie; Cadene, Anthony; Saddoki, Sophia; Debuire, Brigitte; Genet, Roger

    2017-03-01

    a health effect has not been documented. In this context, ANSES recommends: Concerning studies and research: - verifying whether or not there is a possible mechanism modulating the perception of audible sound at intensities of infra-sound similar to those measured from local residents; - studying the effects of the amplitude modulation of the acoustic signal on the noise-related disturbance felt; - studying the assumption that cochlea-vestibular effects may be responsible for pathophysiological effects; - undertaking a survey of residents living near wind farms enabling the identification of an objective signature of a physiological effect. Concerning information for local residents and the monitoring of noise levels: - enhancing information for local residents during the construction of wind farms and participation in public inquiries undertaken in rural areas; - systematically measuring the noise emissions of wind turbines before and after they are brought into service; - setting up, especially in the event of controversy, continuous noise measurement systems around wind farms (based on experience at airports, for example). Lastly, the Agency reiterates that the current regulations state that the distance between a wind turbine and the first home should be evaluated on a case-by-case basis, taking the conditions of wind farms into account. This distance, of at least 500 metres, may be increased further to the results of an impact assessment, in order to comply with the limit values for noise exposure. Current knowledge of the potential health effects of exposure to infra-sounds and low-frequency noise provides no justification for changing the current limit values or for extending the spectrum of noise currently taken into consideration

  3. Sound Art Situations

    DEFF Research Database (Denmark)

    Krogh Groth, Sanne; Samson, Kristine

    2017-01-01

    and combine theories from several fields. Aspects of sound art studies, performance studies and contemporary art studies are presented in order to theoretically explore the very diverse dimensions of the two sound art pieces: Visual, auditory, performative, social, spatial and durational dimensions become......This article is an analysis of two sound art performances that took place June 2015 in outdoor public spaces in the social housing area Urbanplanen in Copenhagen, Denmark. The two performances were On the production of a poor acoustics by Brandon LaBelle and Green Interactive Biofeedback...... Environments (GIBE) by Jeremy Woodruff. In order to investigate the complex situation that arises when sound art is staged in such contexts, the authors of this article suggest exploring the events through approaching them as ‘situations’ (Doherty 2009). With this approach it becomes possible to engage...

  4. Portal monitor incorporating smart probes

    International Nuclear Information System (INIS)

    Bartos, D.; Constantin, F.; Guta, T.

    2003-01-01

    Portal monitors are intended for detection of radioactive and special nuclear materials in vehicles, pedestrians, luggage, as well as for prevention of illegal traffic of radioactive sources. Monitors provide audio and visual alarms when radioactive and/or special nuclear materials are detected. They can be recommended to officers of customs, border guard and emergency services, civil defense, fire brigades, police and military departments or nuclear research or energetic facilities. The portal monitor developed by us consists in a portal frame, which sustains five intelligent probes having long plastic scintillator (0.5 liters each). The probes communicate, by serial transmission, with a Central Unit constructed on the basis of the 80552 microcontroller. This one manages the handshake, calculates the background, establishes the measuring time, starts and stops each measurement and makes all the other decisions. Sound signals and an infrared sensor monitor the passing through the portal and the measuring procedure. For each measurement the result is displayed on a LCD device contaminated/uncontaminated; for the contaminated case a loud and long sound signal is also issued. An RS 232 serial interface is provided in order to further developments or custom made devices. As a result, the portal monitor detects 1 μ Ci 137 Cs, spread all over a human body, in a 20 μR/h gamma background for a measuring time of 1.5 or 10 seconds giving a 99% confidence factor. (authors)

  5. Characteristic sounds facilitate visual search.

    Science.gov (United States)

    Iordanescu, Lucica; Guzman-Martinez, Emmanuel; Grabowecky, Marcia; Suzuki, Satoru

    2008-06-01

    In a natural environment, objects that we look for often make characteristic sounds. A hiding cat may meow, or the keys in the cluttered drawer may jingle when moved. Using a visual search paradigm, we demonstrated that characteristic sounds facilitated visual localization of objects, even when the sounds carried no location information. For example, finding a cat was faster when participants heard a meow sound. In contrast, sounds had no effect when participants searched for names rather than pictures of objects. For example, hearing "meow" did not facilitate localization of the word cat. These results suggest that characteristic sounds cross-modally enhance visual (rather than conceptual) processing of the corresponding objects. Our behavioral demonstration of object-based cross-modal enhancement complements the extensive literature on space-based cross-modal interactions. When looking for your keys next time, you might want to play jingling sounds.

  6. Determining the speed of sound in the air by sound wave interference

    Science.gov (United States)

    Silva, Abel A.

    2017-07-01

    Mechanical waves propagate through material media. Sound is an example of a mechanical wave. In fluids like air, sound waves propagate through successive longitudinal perturbations of compression and decompression. Audible sound frequencies for human ears range from 20 to 20 000 Hz. In this study, the speed of sound v in the air is determined using the identification of maxima of interference from two synchronous waves at frequency f. The values of v were correct to 0 °C. The experimental average value of {\\bar{ν }}\\exp =336 +/- 4 {{m}} {{{s}}}-1 was found. It is 1.5% larger than the reference value. The standard deviation of 4 m s-1 (1.2% of {\\bar{ν }}\\exp ) is an improved value by the use of the concept of the central limit theorem. The proposed procedure to determine the speed of sound in the air aims to be an academic activity for physics classes of scientific and technological courses in college.

  7. Fluid Sounds

    DEFF Research Database (Denmark)

    Explorations and analysis of soundscapes have, since Canadian R. Murray Schafer's work during the early 1970's, developed into various established research - and artistic disciplines. The interest in sonic environments is today present within a broad range of contemporary art projects and in arch......Explorations and analysis of soundscapes have, since Canadian R. Murray Schafer's work during the early 1970's, developed into various established research - and artistic disciplines. The interest in sonic environments is today present within a broad range of contemporary art projects...... and in architectural design. Aesthetics, psychoacoustics, perception, and cognition are all present in this expanding field embracing such categories as soundscape composition, sound art, sonic art, sound design, sound studies and auditory culture. Of greatest significance to the overall field is the investigation...

  8. The influence of environmental sound training on the perception of spectrally degraded speech and environmental sounds.

    Science.gov (United States)

    Shafiro, Valeriy; Sheft, Stanley; Gygi, Brian; Ho, Kim Thien N

    2012-06-01

    Perceptual training with spectrally degraded environmental sounds results in improved environmental sound identification, with benefits shown to extend to untrained speech perception as well. The present study extended those findings to examine longer-term training effects as well as effects of mere repeated exposure to sounds over time. Participants received two pretests (1 week apart) prior to a week-long environmental sound training regimen, which was followed by two posttest sessions, separated by another week without training. Spectrally degraded stimuli, processed with a four-channel vocoder, consisted of a 160-item environmental sound test, word and sentence tests, and a battery of basic auditory abilities and cognitive tests. Results indicated significant improvements in all speech and environmental sound scores between the initial pretest and the last posttest with performance increments following both exposure and training. For environmental sounds (the stimulus class that was trained), the magnitude of positive change that accompanied training was much greater than that due to exposure alone, with improvement for untrained sounds roughly comparable to the speech benefit from exposure. Additional tests of auditory and cognitive abilities showed that speech and environmental sound performance were differentially correlated with tests of spectral and temporal-fine-structure processing, whereas working memory and executive function were correlated with speech, but not environmental sound perception. These findings indicate generalizability of environmental sound training and provide a basis for implementing environmental sound training programs for cochlear implant (CI) patients.

  9. Sound Surfing Network (SSN): Mobile Phone-based Sound Spatialization with Audience Collaboration

    OpenAIRE

    Park, Saebyul; Ban, Seonghoon; Hong, Dae Ryong; Yeo, Woon Seung

    2013-01-01

    SSN (Sound Surfing Network) is a performance system that provides a new musicalexperience by incorporating mobile phone-based spatial sound control tocollaborative music performance. SSN enables both the performer and theaudience to manipulate the spatial distribution of sound using the smartphonesof the audience as distributed speaker system. Proposing a new perspective tothe social aspect music appreciation, SSN will provide a new possibility tomobile music performances in the context of in...

  10. Sound Exposure of Symphony Orchestra Musicians

    DEFF Research Database (Denmark)

    Schmidt, Jesper Hvass; Pedersen, Ellen Raben; Juhl, Peter Møller

    2011-01-01

    dBA and their left ear was exposed 4.6 dB more than the right ear. Percussionists were exposed to high sound peaks >115 dBC but less continuous sound exposure was observed in this group. Musicians were exposed up to LAeq8h of 92 dB and a majority of musicians were exposed to sound levels exceeding......Background: Assessment of sound exposure by noise dosimetry can be challenging especially when measuring the exposure of classical orchestra musicians where sound originate from many different instruments. A new measurement method of bilateral sound exposure of classical musicians was developed...... and used to characterize sound exposure of the left and right ear simultaneously in two different symphony orchestras.Objectives: To measure binaural sound exposure of professional classical musicians and to identify possible exposure risk factors of specific musicians.Methods: Sound exposure was measured...

  11. PET/CT for diagnostics and therapy stratification of lung cancer

    International Nuclear Information System (INIS)

    Kratochwil, C.; Haberkorn, U.; Giesel, F.L.

    2010-01-01

    With the introduction of positron emission tomography (PET) and more recently the hybrid systems PET/CT, the management of cancer patients in the treatment strategy has changed tremendously. The combination of PET with multidetector CT scanning enables the integration of metabolic and high resolution morphological image information. PET/CT is nowadays an established modality for tumor detection, characterization, staging and response monitoring. The increased installation of PET/CT systems worldwide and also the increased scientific publications underline the importance of this imaging modality. PET/CT is particular the imaging modality of choice in lung cancer staging and re-staging (T, N and M staging). The possible increased success of surgery in lung cancer patients and also the expected reduction in additional invasive diagnostics lead to benefits for both the individual patient and the healthcare system. In this review article PET and PET/CT is presented for diagnostic and therapeutic stratification in lung cancer. The fundamentals of glucose metabolism, staging, tumor recurrence and therapeutic monitoring are presented. (orig.) [de

  12. Lung pathologies analyzed with multi-frequency electrical impedance tomography: Pilot animal study.

    Science.gov (United States)

    Aguiar Santos, Susana; Czaplik, Michael; Orschulik, Jakob; Hochhausen, Nadine; Leonhardt, Steffen

    2018-03-31

    In critically ill patients, correct diagnosis of lung disease is essential for successful therapy. Therefore, this study investigated whether new multi-frequency electrical impedance tomography (mfEIT) can detect, monitor and differentiate between pathologies associated with the acute respiratory distress syndrome (ARDS). For this pilot study, 12 pigs were randomized into an ARDS (bronchoalveolar lavage) group (n = 7) and a healthy control group (n = 5). Animals were monitored by means of mfEIT. In addition to functional images, a new impaired-ventilation (rImpVent) index was developed and frequency-difference images were computed and analyzed. Amplitude functional images revealed only small differences between the groups. However, phase functional images were of greater importance in distinguishing between lung pathologies. Correlation images showed substantial differences between the two groups. The new rImpVent index achieved high sensitivity (91%) and specificity (92%) in detecting PaO 2 /FiO 2  ≤ 200 mmHg. mfEIT was able to detect lung edema, differentiate this from atelectasis, and also monitor their progress over time in terms of global and regional differences. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Letter-Sound Reading: Teaching Preschool Children Print-to-Sound Processing

    Science.gov (United States)

    Wolf, Gail Marie

    2016-01-01

    This intervention study investigated the growth of letter sound reading and growth of consonant-vowel-consonant (CVC) word decoding abilities for a representative sample of 41 US children in preschool settings. Specifically, the study evaluated the effectiveness of a 3-step letter-sound teaching intervention in teaching preschool children to…

  14. Idaho National Laboratory Environmental Monitoring Plan

    Energy Technology Data Exchange (ETDEWEB)

    Joanne L. Knight

    2008-04-01

    This plan describes environmental monitoring as required by U.S. Department of Energy (DOE) Order 450.1, “Environmental Protection Program,” and additional environmental monitoring currently performed by other organizations in and around the Idaho National Laboratory (INL). The objective of DOE Order 450.1 is to implement sound stewardship practices that protect the air, water, land, and other natural and cultural resources that may be impacted by DOE operations. This plan describes the organizations responsible for conducting environmental monitoring across the INL, the rationale for monitoring, the types of media being monitored, where the monitoring is conducted, and where monitoring results can be obtained. This plan presents a summary of the overall environmental monitoring performed in and around the INL without duplicating detailed information in the various monitoring procedures and program plans currently used to conduct monitoring.

  15. Modelling Hyperboloid Sound Scattering

    DEFF Research Database (Denmark)

    Burry, Jane; Davis, Daniel; Peters, Brady

    2011-01-01

    The Responsive Acoustic Surfaces workshop project described here sought new understandings about the interaction between geometry and sound in the arena of sound scattering. This paper reports on the challenges associated with modelling, simulating, fabricating and measuring this phenomenon using...... both physical and digital models at three distinct scales. The results suggest hyperboloid geometry, while difficult to fabricate, facilitates sound scattering....

  16. The influence of ski helmets on sound perception and sound localisation on the ski slope

    Directory of Open Access Journals (Sweden)

    Lana Ružić

    2015-04-01

    Full Text Available Objectives: The aim of the study was to investigate whether a ski helmet interferes with the sound localization and the time of sound perception in the frontal plane. Material and Methods: Twenty-three participants (age 30.7±10.2 were tested on the slope in 2 conditions, with and without wearing the ski helmet, by 6 different spatially distributed sound stimuli per each condition. Each of the subjects had to react when hearing the sound as soon as possible and to signalize the correct side of the sound arrival. Results: The results showed a significant difference in the ability to localize the specific ski sounds; 72.5±15.6% of correct answers without a helmet vs. 61.3±16.2% with a helmet (p < 0.01. However, the performance on this test did not depend on whether they were used to wearing a helmet (p = 0.89. In identifying the timing, at which the sound was firstly perceived, the results were also in favor of the subjects not wearing a helmet. The subjects reported hearing the ski sound clues at 73.4±5.56 m without a helmet vs. 60.29±6.34 m with a helmet (p < 0.001. In that case the results did depend on previously used helmets (p < 0.05, meaning that that regular usage of helmets might help to diminish the attenuation of the sound identification that occurs because of the helmets. Conclusions: Ski helmets might limit the ability of a skier to localize the direction of the sounds of danger and might interfere with the moment, in which the sound is firstly heard.

  17. Early development and orientation of the acoustic funnel provides insight into the evolution of sound reception pathways in cetaceans.

    Directory of Open Access Journals (Sweden)

    Maya Yamato

    Full Text Available Whales receive underwater sounds through a fundamentally different mechanism than their close terrestrial relatives. Instead of hearing through the ear canal, cetaceans hear through specialized fatty tissues leading to an evolutionarily novel feature: an acoustic funnel located anterior to the tympanic aperture. We traced the ontogenetic development of this feature in 56 fetal specimens from 10 different families of toothed (odontocete and baleen (mysticete whales, using X-ray computed tomography. We also charted ear ossification patterns through ontogeny to understand the impact of heterochronic developmental processes. We determined that the acoustic funnel arises from a prominent V-shaped structure established early in ontogeny, formed by the malleus and the goniale. In odontocetes, this V-formation develops into a cone-shaped funnel facing anteriorly, directly into intramandibular acoustic fats, which is likely functionally linked to the anterior orientation of sound reception in echolocation. In contrast, the acoustic funnel in balaenopterids rotates laterally, later in fetal development, consistent with a lateral sound reception pathway. Balaenids and several fossil mysticetes retain a somewhat anteriorly oriented acoustic funnel in the mature condition, indicating that a lateral sound reception pathway in balaenopterids may be a recent evolutionary innovation linked to specialized feeding modes, such as lunge-feeding.

  18. 77 FR 37318 - Eighth Coast Guard District Annual Safety Zones; Sound of Independence; Santa Rosa Sound; Fort...

    Science.gov (United States)

    2012-06-21

    ...-AA00 Eighth Coast Guard District Annual Safety Zones; Sound of Independence; Santa Rosa Sound; Fort... Coast Guard will enforce a Safety Zone for the Sound of Independence event in the Santa Rosa Sound, Fort... during the Sound of Independence. During the enforcement period, entry into, transiting or anchoring in...

  19. Estimation of lung volume and pressure from electrocardiogram

    KAUST Repository

    Elsayed, Gamal Eldin Fathy Amin

    2011-05-01

    The Electrocardiography (ECG) is a tool measuring the electrical excitation of the heart that is extensively used for diagnosis and monitoring of heart diseases. The ECG signal reflects not only the heart activity but also many other physiological processes. The respiratory activity is a prominent process that affects the ECG signal due to the close proximity of the heart and the lungs and, on the other hand, due to neural regulatory processes. In this paper, several means for the estimation of the respiratory process from the ECG signal are presented. The results show a strong correlation of the voltage difference between the R and S peak of the ECG and the lung\\'s volume and pressure. Correlation was also found for some features of the vector ECG, which is a two dimensional graph of two different ECG signals. The potential benefit of the multiparametric evaluation of the ECG signal is a reduction of the number of sensors connected to patients, which will increase the patients\\' comfort and reduce the costs associated with healthcare. In particular, it is relevant for sleep monitoring, where a reduction of the number of different sensors would facilitate a more natural sleeping environment and hence a higher sensitivity of the diagnosis. © 2011 IEEE.

  20. Material sound source localization through headphones

    Science.gov (United States)

    Dunai, Larisa; Peris-Fajarnes, Guillermo; Lengua, Ismael Lengua; Montaña, Ignacio Tortajada

    2012-09-01

    In the present paper a study of sound localization is carried out, considering two different sounds emitted from different hit materials (wood and bongo) as well as a Delta sound. The motivation of this research is to study how humans localize sounds coming from different materials, with the purpose of a future implementation of the acoustic sounds with better localization features in navigation aid systems or training audio-games suited for blind people. Wood and bongo sounds are recorded after hitting two objects made of these materials. Afterwards, they are analysed and processed. On the other hand, the Delta sound (click) is generated by using the Adobe Audition software, considering a frequency of 44.1 kHz. All sounds are analysed and convolved with previously measured non-individual Head-Related Transfer Functions both for an anechoic environment and for an environment with reverberation. The First Choice method is used in this experiment. Subjects are asked to localize the source position of the sound listened through the headphones, by using a graphic user interface. The analyses of the recorded data reveal that no significant differences are obtained either when considering the nature of the sounds (wood, bongo, Delta) or their environmental context (with or without reverberation). The localization accuracies for the anechoic sounds are: wood 90.19%, bongo 92.96% and Delta sound 89.59%, whereas for the sounds with reverberation the results are: wood 90.59%, bongo 92.63% and Delta sound 90.91%. According to these data, we can conclude that even when considering the reverberation effect, the localization accuracy does not significantly increase.

  1. Waveform analysis of sound

    CERN Document Server

    Tohyama, Mikio

    2015-01-01

    What is this sound? What does that sound indicate? These are two questions frequently heard in daily conversation. Sound results from the vibrations of elastic media and in daily life provides informative signals of events happening in the surrounding environment. In interpreting auditory sensations, the human ear seems particularly good at extracting the signal signatures from sound waves. Although exploring auditory processing schemes may be beyond our capabilities, source signature analysis is a very attractive area in which signal-processing schemes can be developed using mathematical expressions. This book is inspired by such processing schemes and is oriented to signature analysis of waveforms. Most of the examples in the book are taken from data of sound and vibrations; however, the methods and theories are mostly formulated using mathematical expressions rather than by acoustical interpretation. This book might therefore be attractive and informative for scientists, engineers, researchers, and graduat...

  2. Sound Settlements

    DEFF Research Database (Denmark)

    Mortensen, Peder Duelund; Hornyanszky, Elisabeth Dalholm; Larsen, Jacob Norvig

    2013-01-01

    Præsentation af projektresultater fra Interreg forskningen Sound Settlements om udvikling af bæredygtighed i det almene boligbyggerier i København, Malmø, Helsingborg og Lund samt europæiske eksempler på best practice......Præsentation af projektresultater fra Interreg forskningen Sound Settlements om udvikling af bæredygtighed i det almene boligbyggerier i København, Malmø, Helsingborg og Lund samt europæiske eksempler på best practice...

  3. Sounds of silence: How to animate virtual worlds with sound

    Science.gov (United States)

    Astheimer, Peter

    1993-01-01

    Sounds are an integral and sometimes annoying part of our daily life. Virtual worlds which imitate natural environments gain a lot of authenticity from fast, high quality visualization combined with sound effects. Sounds help to increase the degree of immersion for human dwellers in imaginary worlds significantly. The virtual reality toolkit of IGD (Institute for Computer Graphics) features a broad range of standard visual and advanced real-time audio components which interpret an object-oriented definition of the scene. The virtual reality system 'Virtual Design' realized with the toolkit enables the designer of virtual worlds to create a true audiovisual environment. Several examples on video demonstrate the usage of the audio features in Virtual Design.

  4. How Pleasant Sounds Promote and Annoying Sounds Impede Health: A Cognitive Approach

    Directory of Open Access Journals (Sweden)

    Tjeerd C. Andringa

    2013-04-01

    Full Text Available This theoretical paper addresses the cognitive functions via which quiet and in general pleasurable sounds promote and annoying sounds impede health. The article comprises a literature analysis and an interpretation of how the bidirectional influence of appraising the environment and the feelings of the perceiver can be understood in terms of core affect and motivation. This conceptual basis allows the formulation of a detailed cognitive model describing how sonic content, related to indicators of safety and danger, either allows full freedom over mind-states or forces the activation of a vigilance function with associated arousal. The model leads to a number of detailed predictions that can be used to provide existing soundscape approaches with a solid cognitive science foundation that may lead to novel approaches to soundscape design. These will take into account that louder sounds typically contribute to distal situational awareness while subtle environmental sounds provide proximal situational awareness. The role of safety indicators, mediated by proximal situational awareness and subtle sounds, should become more important in future soundscape research.

  5. Sound synthesis and evaluation of interactive footsteps and environmental sounds rendering for virtual reality applications.

    Science.gov (United States)

    Nordahl, Rolf; Turchet, Luca; Serafin, Stefania

    2011-09-01

    We propose a system that affords real-time sound synthesis of footsteps on different materials. The system is based on microphones, which detect real footstep sounds from subjects, from which the ground reaction force (GRF) is estimated. Such GRF is used to control a sound synthesis engine based on physical models. Two experiments were conducted. In the first experiment, the ability of subjects to recognize the surface they were exposed to was assessed. In the second experiment, the sound synthesis engine was enhanced with environmental sounds. Results show that, in some conditions, adding a soundscape significantly improves the recognition of the simulated environment.

  6. It sounds good!

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Both the atmosphere and we ourselves are hit by hundreds of particles every second and yet nobody has ever heard a sound coming from these processes. Like cosmic rays, particles interacting inside the detectors at the LHC do not make any noise…unless you've decided to use the ‘sonification’ technique, in which case you might even hear the Higgs boson sound like music. Screenshot of the first page of the "LHC sound" site. A group of particle physicists, composers, software developers and artists recently got involved in the ‘LHC sound’ project to make the particles at the LHC produce music. Yes…music! The ‘sonification’ technique converts data into sound. “In this way, if you implement the right software you can get really nice music out of the particle tracks”, says Lily Asquith, a member of the ATLAS collaboration and one of the initiators of the project. The ‘LHC...

  7. Musical Sound, Instruments, and Equipment

    Science.gov (United States)

    Photinos, Panos

    2017-12-01

    'Musical Sound, Instruments, and Equipment' offers a basic understanding of sound, musical instruments and music equipment, geared towards a general audience and non-science majors. The book begins with an introduction of the fundamental properties of sound waves, and the perception of the characteristics of sound. The relation between intensity and loudness, and the relation between frequency and pitch are discussed. The basics of propagation of sound waves, and the interaction of sound waves with objects and structures of various sizes are introduced. Standing waves, harmonics and resonance are explained in simple terms, using graphics that provide a visual understanding. The development is focused on musical instruments and acoustics. The construction of musical scales and the frequency relations are reviewed and applied in the description of musical instruments. The frequency spectrum of selected instruments is explored using freely available sound analysis software. Sound amplification and sound recording, including analog and digital approaches, are discussed in two separate chapters. The book concludes with a chapter on acoustics, the physical factors that affect the quality of the music experience, and practical ways to improve the acoustics at home or small recording studios. A brief technical section is provided at the end of each chapter, where the interested reader can find the relevant physics and sample calculations. These quantitative sections can be skipped without affecting the comprehension of the basic material. Questions are provided to test the reader's understanding of the material. Answers are given in the appendix.

  8. Sound Velocity in Soap Foams

    International Nuclear Information System (INIS)

    Wu Gong-Tao; Lü Yong-Jun; Liu Peng-Fei; Li Yi-Ning; Shi Qing-Fan

    2012-01-01

    The velocity of sound in soap foams at high gas volume fractions is experimentally studied by using the time difference method. It is found that the sound velocities increase with increasing bubble diameter, and asymptotically approach to the value in air when the diameter is larger than 12.5 mm. We propose a simple theoretical model for the sound propagation in a disordered foam. In this model, the attenuation of a sound wave due to the scattering of the bubble wall is equivalently described as the effect of an additional length. This simplicity reasonably reproduces the sound velocity in foams and the predicted results are in good agreement with the experiments. Further measurements indicate that the increase of frequency markedly slows down the sound velocity, whereas the latter does not display a strong dependence on the solution concentration

  9. Low Tidal Volume Reduces Lung Inflammation Induced by Liquid Ventilation in Piglets With Severe Lung Injury.

    Science.gov (United States)

    Jiang, Lijun; Feng, Huizhen; Chen, Xiaofan; Liang, Kaifeng; Ni, Chengyao

    2017-05-01

    Total liquid ventilation (TLV) is an alternative treatment for severe lung injury. High tidal volume is usually required for TLV to maintain adequate CO 2 clearance. However, high tidal volume may cause alveolar barotrauma. We aim to investigate the effect of low tidal volume on pulmonary inflammation in piglets with lung injury and under TLV. After the establishment of acute lung injury model by infusing lipopolysaccharide, 12 piglets were randomly divided into two groups, TLV with high tidal volume (25 mL/kg) or with low tidal volume (6 mL/kg) for 240 min, respectively. Extracorporeal CO 2 removal was applied in low tidal volume group to improve CO 2 clearance and in high tidal volume group as sham control. Gas exchange and hemodynamic status were monitored every 30 min during TLV. At the end of the study, pulmonary mRNA expression and plasmatic concentration of interleukin-6 (IL-6) and interleukin-8 (IL-8) were measured by collecting lung tissue and blood samples from piglets. Arterial blood pressure, PaO 2 , and PaCO 2 showed no remarkable difference between groups during the observation period. Compared with high tidal volume strategy, low tidal volume resulted in 76% reduction of minute volume and over 80% reduction in peak inspiratory pressure during TLV. In addition, low tidal volume significantly diminished pulmonary mRNA expression and plasmatic level of IL-6 and IL-8. We conclude that during TLV, low tidal volume reduces lung inflammation in piglets with acute lung injury without compromising gas exchange. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. OMNIDIRECTIONAL SOUND SOURCE

    DEFF Research Database (Denmark)

    1996-01-01

    A sound source comprising a loudspeaker (6) and a hollow coupler (4) with an open inlet which communicates with and is closed by the loudspeaker (6) and an open outlet, said coupler (4) comprising rigid walls which cannot respond to the sound pressures produced by the loudspeaker (6). According...

  11. The velocity of sound

    International Nuclear Information System (INIS)

    Beyer, R.T.

    1985-01-01

    The paper reviews the work carried out on the velocity of sound in liquid alkali metals. The experimental methods to determine the velocity measurements are described. Tables are presented of reported data on the velocity of sound in lithium, sodium, potassium, rubidium and caesium. A formula is given for alkali metals, in which the sound velocity is a function of shear viscosity, atomic mass and atomic volume. (U.K.)

  12. Imaging of cystic fibrosis lung disease and clinical interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Wielpuetz, M.O.; Eichinger, M.; Kauczor, H.U. [Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology; Translational Lung Research Center Heidelberg (TLRC) (Germany); Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology with Nuclear Medicine; Biederer, J. [Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology; Translational Lung Research Center Heidelberg (TLRC) (Germany); Gross-Gerau Community Hospital (Germany). Radiologie Darmstadt; Wege, S. [Heidelberg University Hospital (Germany). Dept. of Pulmonology and Respiratory Medicine; Stahl, M.; Sommerburg, O. [Translational Lung Research Center Heidelberg (TLRC) (Germany); Heidelberg University Hospital (Germany). Div. of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center; Mall, M.A. [Translational Lung Research Center Heidelberg (TLRC) (Germany); Heidelberg University Hospital (Germany). Div. of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center; Heidelberg University Hospital (Germany). Dept. of Translational Pulmonology; Puderbach, M. [Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology; Translational Lung Research Center Heidelberg (TLRC) (Germany); Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology with Nuclear Medicine; Hufeland Hospital, Bad Langensalza (Germany). Dept. of Diagnostic and Interventional Radiology

    2016-09-15

    Progressive lung disease in cystic fibrosis (CF) is the life-limiting factor of this autosomal recessive genetic disorder. Increasing implementation of CF newborn screening allows for a diagnosis even in pre-symptomatic stages. Improvements in therapy have led to a significant improvement in survival, the majority now being of adult age. Imaging provides detailed information on the regional distribution of CF lung disease, hence longitudinal imaging is recommended for disease monitoring in the clinical routine. Chest X-ray (CXR), computed tomography (CT) and magnetic resonance imaging (MRI) are now available as routine modalities, each with individual strengths and drawbacks, which need to be considered when choosing the optimal modality adapted to the clinical situation of the patient. CT stands out with the highest morphological detail and has often been a substitute for CXR for regular severity monitoring at specialized centers. Multidetector CT data can be post-processed with dedicated software for a detailed measurement of airway dimensions and bronchiectasis and potentially a more objective and precise grading of disease severity. However, changing to CT was inseparably accompanied by an increase in radiation exposure of CF patients, a young population with high sensitivity to ionizing radiation and lifetime accumulation of dose. MRI as a cross-sectional imaging modality free of ionizing radiation can depict morphological hallmarks of CF lung disease at lower spatial resolution but excels with comprehensive functional lung imaging, with time-resolved perfusion imaging currently being most valuable.

  13. Product sounds : Fundamentals and application

    NARCIS (Netherlands)

    Ozcan-Vieira, E.

    2008-01-01

    Products are ubiquitous, so are the sounds emitted by products. Product sounds influence our reasoning, emotional state, purchase decisions, preference, and expectations regarding the product and the product's performance. Thus, auditory experience elicited by product sounds may not be just about

  14. Suppression of sound radiation to far field of near-field acoustic communication system using evanescent sound field

    Science.gov (United States)

    Fujii, Ayaka; Wakatsuki, Naoto; Mizutani, Koichi

    2016-01-01

    A method of suppressing sound radiation to the far field of a near-field acoustic communication system using an evanescent sound field is proposed. The amplitude of the evanescent sound field generated from an infinite vibrating plate attenuates exponentially with increasing a distance from the surface of the vibrating plate. However, a discontinuity of the sound field exists at the edge of the finite vibrating plate in practice, which broadens the wavenumber spectrum. A sound wave radiates over the evanescent sound field because of broadening of the wavenumber spectrum. Therefore, we calculated the optimum distribution of the particle velocity on the vibrating plate to reduce the broadening of the wavenumber spectrum. We focused on a window function that is utilized in the field of signal analysis for reducing the broadening of the frequency spectrum. The optimization calculation is necessary for the design of window function suitable for suppressing sound radiation and securing a spatial area for data communication. In addition, a wide frequency bandwidth is required to increase the data transmission speed. Therefore, we investigated a suitable method for calculating the sound pressure level at the far field to confirm the variation of the distribution of sound pressure level determined on the basis of the window shape and frequency. The distribution of the sound pressure level at a finite distance was in good agreement with that obtained at an infinite far field under the condition generating the evanescent sound field. Consequently, the window function was optimized by the method used to calculate the distribution of the sound pressure level at an infinite far field using the wavenumber spectrum on the vibrating plate. According to the result of comparing the distributions of the sound pressure level in the cases with and without the window function, it was confirmed that the area whose sound pressure level was reduced from the maximum level to -50 dB was

  15. 33 CFR 334.410 - Albemarle Sound, Pamlico Sound, and adjacent waters, NC; danger zones for naval aircraft operations.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Albemarle Sound, Pamlico Sound... AND RESTRICTED AREA REGULATIONS § 334.410 Albemarle Sound, Pamlico Sound, and adjacent waters, NC; danger zones for naval aircraft operations. (a) Target areas—(1) North Landing River (Currituck Sound...

  16. Uncertain added value of Global Trigger Tool for monitoring of patient safety in cancer care

    DEFF Research Database (Denmark)

    Lipczak, Henriette; Neckelmann, Kirsten; Steding-Jessen, Marianne

    2011-01-01

    Monitoring patient safety is a challenging task. The lack of a golden standard has contributed to the recommendation and introduction of several methods. In 2000 the Danish Lung Cancer Registry (DLCR) was established to monitor the clinical management of lung cancer. In 2008 the Global Trigger Tool...... (GTT) was recommended in Denmark as a tool for the monitoring of patient safety. Ideally, the recommendation of a new tool should be preceded by a critical assessment of its added value....

  17. Development of database management system for monitoring of radiation workers for actinides

    International Nuclear Information System (INIS)

    Kalyane, G.N.; Mishra, L.; Nadar, M.Y.; Singh, I.S.; Rao, D.D.

    2012-01-01

    Annually around 500 radiation workers are monitored for estimation of lung activities and internal dose due to Pu/Am and U from various divisions of Bhabha Atomic Research Centre (Trombay) and from PREFRE and A3F facilities (Tarapur) in lung counting laboratory located at Bhabha Atomic Research Centre hospital under Routine and Special monitoring program. A 20 cm diameter phoswich and an array of HPGe detector were used for this purpose. In case of positive contamination, workers are followed up and monitored using both the detection systems in different geometries. Management of this huge data becomes difficult and therefore an easily retrievable database system containing all the relevant data of the monitored radiation workers. Materials and methods: The database management system comprises of three main modules integrated together: 1) Apache server installed on a Windows (XP) platform (Apache version 2.2.17) 2) MySQL database management system (MySQL version 5.5.8) 3) PHP (Preformatted Hypertext) programming language (PHP version 5.3.5). All the 3 modules work together seamlessly as a single software program. The front end user interaction is through an user friendly and interactive local web page where internet connection is not required. This front page has hyperlinks to many other pages, which have different utilities for the user. The user has to log in using username and password. Results and Conclusions: Database management system is used for entering, updating and management of lung monitoring data of radiation workers, The program is having following utilities: bio-data entry of new subjects, editing of bio-data of old subjects (only one subject at a time), entry of counting data of that day's lung monitoring, retrieval of old records based on a number of parameters and filters like date of counting, employee number, division, counts fulfilling a given criterion, etc. and calculation of MEQ CWT (Muscle Equivalent Chest Wall Thickness), energy

  18. Impulse oscillometry: The state-of-art for lung function testing

    Directory of Open Access Journals (Sweden)

    Koundinya Desiraju

    2016-01-01

    Full Text Available Impulse oscillometry (IOS is a variant of forced oscillation technique, described by Dubois over 50 years ago, which permits passive measurement of lung mechanics. In this method, sound waves are superimposed on normal tidal breathing, and the disturbances in flow and pressure caused by the external waves are used to calculate parameters describing the resistance to airflow and reactive parameters that mostly relate to efficient storage and return of energy by the lung. It requires minimal patient cooperation and can be done easily in subjects who are unable to perform spirometry. Importantly, IOS can differentiate small airway obstruction from large airway obstruction and is more sensitive than spirometry for peripheral airway disease. It has been used to study various respiratory disorders, especially asthma and is suitable for measuring bronchodilatory response as well as bronchoprovocation testing. IOS parameters seem to be able to pick up early changes in lung functon such that they are superior to spirometry in predicting loss of control in asthmatic patients and possibly in identifying early airway disease in smokers. Such comparisons, especially for chronic obstructive pulmonary disease, are made difficult by widespread use of spirometric parameters as the diagnostic gold standard. Here, we discuss the principles and technique of IOS and review its application in obstructive airway diseases.

  19. Simulation of Sound Waves Using the Lattice Boltzmann Method for Fluid Flow: Benchmark Cases for Outdoor Sound Propagation.

    Science.gov (United States)

    Salomons, Erik M; Lohman, Walter J A; Zhou, Han

    2016-01-01

    Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases: free-field propagation, propagation over porous and non-porous ground, propagation over a noise barrier, and propagation in an atmosphere with wind. LBM results are compared with solutions of the equations of acoustics. It is found that the LBM works well for sound waves, but dissipation of sound waves with the LBM is generally much larger than real dissipation of sound waves in air. To circumvent this problem it is proposed here to use the LBM for assessing the excess sound level, i.e. the difference between the sound level and the free-field sound level. The effect of dissipation on the excess sound level is much smaller than the effect on the sound level, so the LBM can be used to estimate the excess sound level for a non-dissipative atmosphere, which is a useful quantity in atmospheric acoustics. To reduce dissipation in an LBM simulation two approaches are considered: i) reduction of the kinematic viscosity and ii) reduction of the lattice spacing.

  20. Sounding out the logo shot

    OpenAIRE

    Nicolai Jørgensgaard Graakjær

    2013-01-01

    This article focuses on how sound in combination with visuals (i.e. ‘branding by’) may possibly affect the signifying potentials (i.e. ‘branding effect’) of products and corporate brands (i.e. ‘branding of’) during logo shots in television commercials (i.e. ‘branding through’). This particular focus adds both to the understanding of sound in television commercials and to the understanding of sound brands. The article firstly presents a typology of sounds. Secondly, this typology is applied...

  1. Sound intensity

    DEFF Research Database (Denmark)

    Crocker, Malcolm J.; Jacobsen, Finn

    1998-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  2. Sound Intensity

    DEFF Research Database (Denmark)

    Crocker, M.J.; Jacobsen, Finn

    1997-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  3. SoleSound

    DEFF Research Database (Denmark)

    Zanotto, Damiano; Turchet, Luca; Boggs, Emily Marie

    2014-01-01

    This paper introduces the design of SoleSound, a wearable system designed to deliver ecological, audio-tactile, underfoot feedback. The device, which primarily targets clinical applications, uses an audio-tactile footstep synthesis engine informed by the readings of pressure and inertial sensors...... embedded in the footwear to integrate enhanced feedback modalities into the authors' previously developed instrumented footwear. The synthesis models currently implemented in the SoleSound simulate different ground surface interactions. Unlike similar devices, the system presented here is fully portable...

  4. Prenatal stress challenge impairs fetal lung development and asthma severity sex-specifically in mice.

    Science.gov (United States)

    Zazara, Dimitra E; Perani, Clara V; Solano, María E; Arck, Petra C

    2018-02-01

    Allergic asthma is an increasing health problem worldwide. Interestingly, prenatal challenges such as stress have been associated with an increased risk for asthma during childhood. The underlying pathogenesis of how prenatal stress increases the risk for asthma still remains unclear. Potential targets could be that the fetal immune ontogeny or fetal lung development are compromised by prenatal challenges. Here, we aimed to identify whether prenatal stress challenge affects fetal lung development in mice. C57BL/6 pregnant mice were challenged with sound stress and fetal lung development was assessed histologically. Whilst prenatal stress challenge did not profoundly affect lung development in male fetuses, it resulted in less extensive terminal sacs, surrounded by thicker mesenchymal tissue in female fetuses. Thus, prenatal stress disrupted fetal lung development sex-specifically. Interestingly, upon prenatal stress challenge, the airway hyperresponsiveness and eosinophilic inflammation- two hallmarks of asthma - were significantly increased in adult female offspring, whilst regulatory CD4+ T cells were reduced. These findings strongly underpin the sex-specific association between s challenged fetal development and a sex-specific altered severity of asthma in adult offspring. Our model now allows to identify maternal markers through which the risk for asthma and possible other diseases is vertically transferred before birth in response to challenges. Such identification then opens avenues for primary disease prevention. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Sound engineering for diesel engines; Sound Engineering an Dieselmotoren

    Energy Technology Data Exchange (ETDEWEB)

    Enderich, A.; Fischer, R. [MAHLE Filtersysteme GmbH, Stuttgart (Germany)

    2006-07-01

    The strong acceptance for vehicles powered by turbo-charged diesel engines encourages several manufacturers to think about sportive diesel concepts. The approach of suppressing unpleasant noise by the application of distinctive insulation steps is not adequate to satisfy sportive needs. The acoustics cannot follow the engine's performance. This report documents, that it is possible to give diesel-powered vehicles a sportive sound characteristic by using an advanced MAHLE motor-sound-system with a pressure-resistant membrane and an integrated load controlled flap. With this the specific acoustic disadvantages of the diesel engine, like the ''diesel knock'' or a rough engine running can be masked. However, by the application of a motor-sound-system you must not negate the original character of the diesel engine concept, but accentuate its strong torque characteristic in the middle engine speed range. (orig.)

  6. Sonic mediations: body, sound, technology

    NARCIS (Netherlands)

    Birdsall, C.; Enns, A.

    2008-01-01

    Sonic Mediations: Body, Sound, Technology is a collection of original essays that represents an invaluable contribution to the burgeoning field of sound studies. While sound is often posited as having a bridging function, as a passive in-between, this volume invites readers to rethink the concept of

  7. System for actively reducing sound

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2005-01-01

    A system for actively reducing sound from a primary noise source, such as traffic noise, comprising: a loudspeaker connector for connecting to at least one loudspeaker for generating anti-sound for reducing said noisy sound; a microphone connector for connecting to at least a first microphone placed

  8. Ambient Monitoring for Sinclair and Dyes Inlets, Puget Sound, Washington: Chemical Analyses for 2010 Regional Mussel Watch (AMB02)

    Energy Technology Data Exchange (ETDEWEB)

    Brandenberger, Jill M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kuo, Li-Jung [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Suslick, Carolynn R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnston, Robert K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2010-10-20

    The Puget Sound Naval Shipyard & Intermediate Maintenance Facility (PSNS&IMF) and Naval Base Kitsap-Bremerton (Shipyard) located in Bremerton, WA are committed to a culture of continuous process improvement for all aspects of Shipyard operations, including reducing the releases of hazardous materials and waste in discharges from the Shipyard. Under the Project ENVVEST Final Project Agreement, a cooperative project among PSNS&IMF, the Environmental Protection Agency (EPA), and the Washington State Department of Ecology (Ecology), and local stakeholders (US Navy, EPA and Ecology 2002) has been helping to improve the environmental quality of the Sinclair and Dyes Inlet Watershed (ENVVEST 2006). An ambient monitoring program for sediment, water, and indigenous mussels began in 2009 to assess the status and trend of ecological resources, assess the effectiveness of cleanup and pollution control measures, and determine if discharges from all sources are protective of beneficial uses including aquatic life. This document presents the 2010 chemical residue data and stable isotopes of carbon (δ13C) and nitrogen (δ15N) for the regional mussel watch stations located in Sinclair Inlet, Dyes Inlet, Port Orchard Passage, Rich Passage, Agate Passage, Liberty Bay, and Keyport Lagoon. Indigenous bivalves were collected from a small boat and/or from along the shoreline, measured, composited, and analyzed for a suite of trace metals and organic contaminants. The trace metals included silver, arsenic, cadmium, chromium, copper, mercury, nickel, lead, and zinc. The organic contaminants included the list of NOAA Status and Trends 20 polychlorinated biphenyls (PCB) congeners and suite of parent and methylated polycyclic aromatic hydrocarbons (PAHs). These chemical residue data provide the first year of the biota ambient monitoring.

  9. The Russian experience of monitoring technologies

    International Nuclear Information System (INIS)

    Kolesnikov, A.L.

    1999-01-01

    The implementation of nuclear test monitoring, the observance of international nuclear weapon limitation and test ban agreements is assigned to the Special Monitoring Service at the Ministry of defence in Russian Federation. The system of collecting, processing, analysis and generalization of the data on nuclear tests has been created and is functioning in the Special Monitoring Service. This system is based on the application of the facilities of the seismic, infra sound, radionuclide and other monitoring methods. The Service has all the necessary scientific and technical basis, the perfect mechanism for solving the monitoring problems. Its activities cover data collecting and processing centres as well as special monitoring laboratory equipment, integrated in the unified computer aide system. Besides the experiences of the Russian Service, the possible ways of cooperation with CTBTO are described

  10. Idaho National Laboratory Site Environmental Monitoring Plan

    Energy Technology Data Exchange (ETDEWEB)

    Joanne L. Knight

    2012-08-01

    This plan describes environmental monitoring as required by U.S. Department of Energy (DOE) Order 450.1, “Environmental Protection Program,” and additional environmental monitoring currently performed by other organizations in and around the Idaho National Laboratory (INL). The objective of DOE Order 450.1 is to implement sound stewardship practices that protect the air, water, land, and other natural and cultural resources that may be impacted by DOE operations. This plan describes the organizations responsible for conducting environmental monitoring across the INL, the rationale for monitoring, the types of media being monitored, where the monitoring is conducted, and where monitoring results can be obtained. This plan presents a summary of the overall environmental monitoring performed in and around the INL without duplicating detailed information in the various monitoring procedures and program plans currently used to conduct monitoring.

  11. Idaho National Laboratory Site Environmental Monitoring Plan

    Energy Technology Data Exchange (ETDEWEB)

    Joanne L. Knight

    2010-10-01

    This plan describes environmental monitoring as required by U.S. Department of Energy (DOE) Order 450.1, “Environmental Protection Program,” and additional environmental monitoring currently performed by other organizations in and around the Idaho National Laboratory (INL). The objective of DOE Order 450.1 is to implement sound stewardship practices that protect the air, water, land, and other natural and cultural resources that may be impacted by DOE operations. This plan describes the organizations responsible for conducting environmental monitoring across the INL, the rationale for monitoring, the types of media being monitored, where the monitoring is conducted, and where monitoring results can be obtained. This plan presents a summary of the overall environmental monitoring performed in and around the INL without duplicating detailed information in the various monitoring procedures and program plans currently used to conduct monitoring.

  12. Measuring the 'complexity'of sound

    Indian Academy of Sciences (India)

    Sounds in the natural environment form an important class of biologically relevant nonstationary signals. We propose a dynamic spectral measure to characterize the spectral dynamics of such non-stationary sound signals and classify them based on rate of change of spectral dynamics. We categorize sounds with slowly ...

  13. Controlling sound with acoustic metamaterials

    DEFF Research Database (Denmark)

    Cummer, Steven A. ; Christensen, Johan; Alù, Andrea

    2016-01-01

    Acoustic metamaterials can manipulate and control sound waves in ways that are not possible in conventional materials. Metamaterials with zero, or even negative, refractive index for sound offer new possibilities for acoustic imaging and for the control of sound at subwavelength scales....... The combination of transformation acoustics theory and highly anisotropic acoustic metamaterials enables precise control over the deformation of sound fields, which can be used, for example, to hide or cloak objects from incident acoustic energy. Active acoustic metamaterials use external control to create......-scale metamaterial structures and converting laboratory experiments into useful devices. In this Review, we outline the designs and properties of materials with unusual acoustic parameters (for example, negative refractive index), discuss examples of extreme manipulation of sound and, finally, provide an overview...

  14. Review of scientific information on impacts of seismic sound on fish, invertebrates, marine turtles and marine mammals

    Energy Technology Data Exchange (ETDEWEB)

    Bain, H.

    2004-09-01

    This review of scientific literature on impacts of seismic sound on aquatic organisms was initiated following a 2003 workshop to develop a decision framework for seismic survey referrals in Canadian waters. That workshop revealed that there are sources of uncertainty about the effects of seismic sound on aquatic organisms. It was determined that seismic sounds on the marine environment are not completely without consequence nor are they certain to result in serious harm. Following the workshop, and in order to clearly determine the level of risk posed by seismic sounds, teams of scientists prepared reviews of literature on experimental studies and field monitoring on the effects of seismic sound on marine organisms. Standards and mitigation methods were also reviewed. The scientific deliberations resulted in a body of information that allowed several conclusions to be reached that provide a scientific basis for developing a regulatory framework for conducting seismic surveys in marine environments. This paper presented literature highlights regarding: habitat concern; management considerations; physical and behavioural effects on fish; functional uses of sound; physical, physiological and behavioural effects on invertebrates; effects of seismic sound on zooplankton, eggs, larvae of fish and invertebrates; effect of seismic sound on marine turtles; and mortality, physical and behavioural effects on marine mammals. The literature review sought to seek if seismic sound contributed to displacement and migratory diversion; changes in dive and respiratory patterns; changes in social behaviour; and changes in vocalisation patterns. Several areas of future research needs were identified following this literature review which revealed that the long-term effects of seismic sound on marine animals remain inconclusive. 2 refs., 1 fig.

  15. Sound intensity as a function of sound insulation partition

    OpenAIRE

    Cvetkovic , S.; Prascevic , R.

    1994-01-01

    In the modern engineering practice, the sound insulation of the partitions is the synthesis of the theory and of the experience acquired in the procedure of the field and of the laboratory measurement. The science and research public treat the sound insulation in the context of the emission and propagation of the acoustic energy in the media with the different acoustics impedance. In this paper, starting from the essence of physical concept of the intensity as the energy vector, the authors g...

  16. Remote Sensing of Suspended Sediment Dynamics in the Mississippi Sound

    Science.gov (United States)

    Merritt, D. N.; Skarke, A. D.; Silwal, S.; Dash, P.

    2016-02-01

    The Mississippi Sound is a semi-enclosed estuary between the coast of Mississippi and a chain of offshore barrier islands with relatively shallow water depths and high marine biodiversity that is wildly utilized for commercial fishing and public recreation. The discharge of sediment-laden rivers into the Mississippi Sound and the adjacent Northern Gulf of Mexico creates turbid plumes that can extend hundreds of square kilometers along the coast and persist for multiple days. The concentration of suspended sediment in these coastal waters is an important parameter in the calculation of regional sediment budgets as well as analysis of water-quality factors such as primary productivity, nutrient dynamics, and the transport of pollutants as well as pathogens. The spectral resolution, sampling frequency, and regional scale spatial domain associated with satellite based sensors makes remote sensing an ideal tool to monitor suspended sediment dynamics in the Northern Gulf of Mexico. Accordingly, the presented research evaluates the validity of published models that relate remote sensing reflectance with suspended sediment concentrations (SSC), for similar environmental settings, with 51 in situ observations of SSC from the Mississippi Sound. Additionally, regression analysis is used to correlate additional in situ observations of SSC in Mississippi Sound with coincident observations of visible and near-infrared band reflectance collected by the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor aboard the Aqua satellite, in order to develop a site-specific empirical predictive model for SSC. Finally, specific parameters of the sampled suspended sediment such as grain size and mineralogy are analyzed in order to quantify their respective contributions to total remotely sensed reflectance.

  17. Lung cancer screening. What have we learnt for the practice so far?

    International Nuclear Information System (INIS)

    Schaefer-Prokop, C.; Prosch, H.; Prokop, M.

    2014-01-01

    Lung cancer is the most frequent cause of tumor-associated death and only has a good prognosis if detected at a very early tumor stage. For the first time the American National Lung Screening Trial (NLST) could prove that low-dose computed tomography (CT) screening is able to reduce lung cancer mortality by 20 %. To date, however, three much smaller and therefore statistically underpowered European trials could not confirm the positive results of the NLST. The results of the largest European trial NELSON are expected within the next 2 years. In addition, there are a number of open or not yet satisfactorily answered questions, such as the definition of the appropriate screening population, the management of nodules detected by screening, the effects of over-diagnosis and the risk of cumulative radiation exposure. The success of the NLST prompted several predominantly American professional societies to issue a positive recommendation about the implementation of lung cancer screening in a population at risk. However, potentially conflicting results of European studies and a number of not yet optimized issues justify caution and call for a pooled analysis of European studies in order to provide statistically sound results and to ensure a high efficiency of screening with respect to the radiation applied, mental and physical patient burden and, last but not least, the financial efforts. (orig.) [de

  18. Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette.

    Science.gov (United States)

    Altuncu, E; Akman, I; Kulekci, S; Akdas, F; Bilgen, H; Ozek, E

    2009-07-01

    The purposes of this study were to measure the noise level of a busy neonatal intensive care unit (NICU) and to determine the effect of sound absorbing panel (SAP) on the level of noise inside the isolette. The sound pressure levels (SPL) of background noise, baby crying, alarms and closing of isolette's door/portholes were measured by a 2235-Brüel&Kjaer Sound Level Meter. Readings were repeated after applying SAP (3D pyramidal shaped open cell polyurethane foam) to the three lateral walls and ceiling of the isolette. The median SPL of background noise inside the NICU was 56dBA and it decreased to 47dBA inside the isolette. The median SPL of monitor alarms and baby crying inside the isolette were not different than SPL measured under radiant warmer (p>0.05). With SAP, the median SPL of temperature alarm inside the isolette decreased significantly from 82 to 72dBA, monitor alarm from 64 to 56dBA, porthole closing from 81 to 74dBA, and isolette door closing from 80 to 68dBA (pnoise produced by baby crying when SAP was used in the isolette (79dBA vs 69dBA, respectively) (pnoise. The noise level in our NICU is significantly above the universally recommended levels. Being inside the isolette protects infants from noise sources produced outside the isolette. However, very high noises are produced inside the isolette as well. Sound absorbing panel can be a simple solution and it attenuated the noise levels inside the isolette.

  19. Interactive physically-based sound simulation

    Science.gov (United States)

    Raghuvanshi, Nikunj

    The realization of interactive, immersive virtual worlds requires the ability to present a realistic audio experience that convincingly compliments their visual rendering. Physical simulation is a natural way to achieve such realism, enabling deeply immersive virtual worlds. However, physically-based sound simulation is very computationally expensive owing to the high-frequency, transient oscillations underlying audible sounds. The increasing computational power of desktop computers has served to reduce the gap between required and available computation, and it has become possible to bridge this gap further by using a combination of algorithmic improvements that exploit the physical, as well as perceptual properties of audible sounds. My thesis is a step in this direction. My dissertation concentrates on developing real-time techniques for both sub-problems of sound simulation: synthesis and propagation. Sound synthesis is concerned with generating the sounds produced by objects due to elastic surface vibrations upon interaction with the environment, such as collisions. I present novel techniques that exploit human auditory perception to simulate scenes with hundreds of sounding objects undergoing impact and rolling in real time. Sound propagation is the complementary problem of modeling the high-order scattering and diffraction of sound in an environment as it travels from source to listener. I discuss my work on a novel numerical acoustic simulator (ARD) that is hundred times faster and consumes ten times less memory than a high-accuracy finite-difference technique, allowing acoustic simulations on previously-intractable spaces, such as a cathedral, on a desktop computer. Lastly, I present my work on interactive sound propagation that leverages my ARD simulator to render the acoustics of arbitrary static scenes for multiple moving sources and listener in real time, while accounting for scene-dependent effects such as low-pass filtering and smooth attenuation

  20. 27 CFR 9.151 - Puget Sound.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Puget Sound. 9.151 Section... Sound. (a) Name. The name of the viticultural area described in this section is “Puget Sound.” (b) Approved maps. The appropriate maps for determining the boundary of the Puget Sound viticultural area are...

  1. How Pleasant Sounds Promote and Annoying Sounds Impede Health : A Cognitive Approach

    NARCIS (Netherlands)

    Andringa, Tjeerd C.; Lanser, J. Jolie L.

    2013-01-01

    This theoretical paper addresses the cognitive functions via which quiet and in general pleasurable sounds promote and annoying sounds impede health. The article comprises a literature analysis and an interpretation of how the bidirectional influence of appraising the environment and the feelings of

  2. Of Sound Mind: Mental Distress and Sound in Twentieth-Century Media Culture

    NARCIS (Netherlands)

    Birdsall, C.; Siewert, S.

    2013-01-01

    This article seeks to specify the representation of mental disturbance in sound media during the twentieth century. It engages perspectives on societal and technological change across the twentieth century as crucial for aesthetic strategies developed in radio and sound film production. The analysis

  3. Sounds scary? Lack of habituation following the presentation of novel sounds.

    Directory of Open Access Journals (Sweden)

    Tine A Biedenweg

    Full Text Available BACKGROUND: Animals typically show less habituation to biologically meaningful sounds than to novel signals. We might therefore expect that acoustic deterrents should be based on natural sounds. METHODOLOGY: We investigated responses by western grey kangaroos (Macropus fulignosus towards playback of natural sounds (alarm foot stomps and Australian raven (Corvus coronoides calls and artificial sounds (faux snake hiss and bull whip crack. We then increased rate of presentation to examine whether animals would habituate. Finally, we varied frequency of playback to investigate optimal rates of delivery. PRINCIPAL FINDINGS: Nine behaviors clustered into five Principal Components. PC factors 1 and 2 (animals alert or looking, or hopping and moving out of area accounted for 36% of variance. PC factor 3 (eating cessation, taking flight, movement out of area accounted for 13% of variance. Factors 4 and 5 (relaxing, grooming and walking; 12 and 11% of variation, respectively discontinued upon playback. The whip crack was most evocative; eating was reduced from 75% of time spent prior to playback to 6% following playback (post alarm stomp: 32%, raven call: 49%, hiss: 75%. Additionally, 24% of individuals took flight and moved out of area (50 m radius in response to the whip crack (foot stomp: 0%, raven call: 8% and 4%, hiss: 6%. Increasing rate of presentation (12x/min ×2 min caused 71% of animals to move out of the area. CONCLUSIONS/SIGNIFICANCE: The bull whip crack, an artificial sound, was as effective as the alarm stomp at eliciting aversive behaviors. Kangaroos did not fully habituate despite hearing the signal up to 20x/min. Highest rates of playback did not elicit the greatest responses, suggesting that 'more is not always better'. Ultimately, by utilizing both artificial and biological sounds, predictability may be masked or offset, so that habituation is delayed and more effective deterrents may be produced.

  4. Sound localization and occupational noise

    Directory of Open Access Journals (Sweden)

    Pedro de Lemos Menezes

    2014-02-01

    Full Text Available OBJECTIVE: The aim of this study was to determine the effects of occupational noise on sound localization in different spatial planes and frequencies among normal hearing firefighters. METHOD: A total of 29 adults with pure-tone hearing thresholds below 25 dB took part in the study. The participants were divided into a group of 19 firefighters exposed to occupational noise and a control group of 10 adults who were not exposed to such noise. All subjects were assigned a sound localization task involving 117 stimuli from 13 sound sources that were spatially distributed in horizontal, vertical, midsagittal and transverse planes. The three stimuli, which were square waves with fundamental frequencies of 500, 2,000 and 4,000 Hz, were presented at a sound level of 70 dB and were randomly repeated three times from each sound source. The angle between the speaker's axis in the same plane was 45°, and the distance to the subject was 1 m. RESULT: The results demonstrate that the sound localization ability of the firefighters was significantly lower (p<0.01 than that of the control group. CONCLUSION: Exposure to occupational noise, even when not resulting in hearing loss, may lead to a diminished ability to locate a sound source.

  5. Underwater Sound Levels at a Wave Energy Device Testing Facility in Falmouth Bay, UK.

    Science.gov (United States)

    Garrett, Joanne K; Witt, Matthew J; Johanning, Lars

    2016-01-01

    Passive acoustic monitoring devices were deployed at FaBTest in Falmouth Bay, UK, a marine renewable energy device testing facility during trials of a wave energy device. The area supports considerable commercial shipping and recreational boating along with diverse marine fauna. Noise monitoring occurred during (1) a baseline period, (2) installation activity, (3) the device in situ with inactive power status, and (4) the device in situ with active power status. This paper discusses the preliminary findings of the sound recording at FabTest during these different activity periods of a wave energy device trial.

  6. Quantitative assessment of irradiated lung volume and lung mass in breast cancer patients treated with tangential fields in combination with deep inspiration breath hold (DIBH)

    International Nuclear Information System (INIS)

    Kapp, Karin Sigrid; Zurl, Brigitte; Stranzl, Heidi; Winkler, Peter

    2010-01-01

    Purpose: Comparison of the amount of irradiated lung tissue volume and mass in patients with breast cancer treated with an optimized tangential-field technique with and without a deep inspiration breath-hold (DIBH) technique and its impact on the normal-tissue complication probability (NTCP). Material and Methods: Computed tomography datasets of 60 patients in normal breathing (NB) and subsequently in DIBH were compared. With a Real-Time Position Management Respiratory Gating System (RPM), anteroposterior movement of the chest wall was monitored and a lower and upper threshold were defined. Ipsilateral lung and a restricted tangential region of the lung were delineated and the mean and maximum doses calculated. Irradiated lung tissue mass was computed based on density values. NTCP for lung was calculated using a modified Lyman-Kutcher-Burman (LKB) model. Results: Mean dose to the ipsilateral lung in DIBH versus NB was significantly reduced by 15%. Mean lung mass calculation in the restricted area receiving ≤ 20 Gy (M 20 ) was reduced by 17% in DIBH but associated with an increase in volume. NTCP showed an improvement in DIBH of 20%. The correlation of individual breathing amplitude with NTCP proved to be independent. Conclusion: The delineation of a restricted area provides the lung mass calculation in patients treated with tangential fields. DIBH reduces ipsilateral lung dose by inflation so that less tissue remains in the irradiated region and its efficiency is supported by a decrease of NTCP. (orig.)

  7. Pressure sound level measurements at an educational environment in Goiânia, Goiás, Brazil

    Science.gov (United States)

    Costa, J. J. L.; do Nascimento, E. O.; de Oliveira, L. N.; Caldas, L. V. E.

    2018-03-01

    In this work, 25 points located on the ground floor of the Federal Institute of Education, Science and Technology of Goias - IFG - Campus Goiânia, were analyzed in morning periods of two Saturdays. The pressure sound levels were measured at internal and external environments during routine activities seeking to perform an environmental monitoring at this institution. The initial hypothesis was that an amusement park (Mutirama Park) was responsible for originating noise pollution in the institute, but the results showed, within the campus environment, sound pressure levels in accordance with the Municipal legislation of Goiânia for all points.

  8. Extravascular Lung Water and Acute Lung Injury

    Directory of Open Access Journals (Sweden)

    Ritesh Maharaj

    2012-01-01

    Full Text Available Acute lung injury carries a high burden of morbidity and mortality and is characterised by nonhydrostatic pulmonary oedema. The aim of this paper is to highlight the role of accurate quantification of extravascular lung water in diagnosis, management, and prognosis in “acute lung injury” and “acute respiratory distress syndrome”. Several studies have verified the accuracy of both the single and the double transpulmonary thermal indicator techniques. Both experimental and clinical studies were searched in PUBMED using the term “extravascular lung water” and “acute lung injury”. Extravascular lung water measurement offers information not otherwise available by other methods such as chest radiography, arterial blood gas, and chest auscultation at the bedside. Recent data have highlighted the role of extravascular lung water in response to treatment to guide fluid therapy and ventilator strategies. The quantification of extravascular lung water may predict mortality and multiorgan dysfunction. The limitations of the dilution method are also discussed.

  9. Lung Cancer Serum Biomarker Discovery Using Label Free LC-MS/MS

    Science.gov (United States)

    Zeng, Xuemei; Hood, Brian L.; Zhao, Ting; Conrads, Thomas P.; Sun, Mai; Gopalakrishnan, Vanathi; Grover, Himanshu; Day, Roger S.; Weissfeld, Joel L.; Wilson, David O.; Siegfried, Jill M.; Bigbee, William L.

    2011-01-01

    Introduction Lung cancer remains the leading cause of cancer-related death with poor survival due to the late stage at which lung cancer is typically diagnosed. Given the clinical burden from lung cancer, and the relatively favorable survival associated with early stage lung cancer, biomarkers for early detection of lung cancer are of important potential clinical benefit. Methods We performed a global lung cancer serum biomarker discovery study using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in a set of pooled non-small cell lung cancer (NSCLC) case sera and matched controls. Immunoaffinity subtraction was used to deplete the top most abundant serum proteins; the remaining serum proteins were subjected to trypsin digestion and analyzed in triplicate by LC-MS/MS. The tandem mass spectrum data were searched against the human proteome database and the resultant spectral counting data were used to estimate the relative abundance of proteins across the case/control serum pools. The spectral counting derived abundances of some candidate biomarker proteins were confirmed with multiple reaction monitoring MS assays. Results A list of 49 differentially abundant candidate proteins was compiled by applying a negative binomial regression model to the spectral counting data (pbiomarkers with statistically significant differential abundance across the lung cancer case/control pools which, when validated, could improve lung cancer early detection. PMID:21304412

  10. The effect of sound speed profile on shallow water shipping sound maps

    NARCIS (Netherlands)

    Sertlek, H.Ö.; Binnerts, B.; Ainslie, M.A.

    2016-01-01

    Sound mapping over large areas can be computationally expensive because of the large number of sources and large source-receiver separations involved. In order to facilitate computation, a simplifying assumption sometimes made is to neglect the sound speed gradient in shallow water. The accuracy of

  11. Sound wave transmission (image)

    Science.gov (United States)

    When sounds waves reach the ear, they are translated into nerve impulses. These impulses then travel to the brain where they are interpreted by the brain as sound. The hearing mechanisms within the inner ear, can ...

  12. Sound & The Society

    DEFF Research Database (Denmark)

    Schulze, Holger

    2014-01-01

    How are those sounds you hear right now socially constructed and evaluated, how are they architecturally conceptualized and how dependant on urban planning, industrial developments and political decisions are they really? How is your ability to hear intertwined with social interactions and their ...... and their professional design? And how is listening and sounding a deeply social activity – constructing our way of living together in cities as well as in apartment houses? A radio feature with Nina Backmann, Jochen Bonz, Stefan Krebs, Esther Schelander & Holger Schulze......How are those sounds you hear right now socially constructed and evaluated, how are they architecturally conceptualized and how dependant on urban planning, industrial developments and political decisions are they really? How is your ability to hear intertwined with social interactions...

  13. Predicting outdoor sound

    CERN Document Server

    Attenborough, Keith; Horoshenkov, Kirill

    2014-01-01

    1. Introduction  2. The Propagation of Sound Near Ground Surfaces in a Homogeneous Medium  3. Predicting the Acoustical Properties of Outdoor Ground Surfaces  4. Measurements of the Acoustical Properties of Ground Surfaces and Comparisons with Models  5. Predicting Effects of Source Characteristics on Outdoor Sound  6. Predictions, Approximations and Empirical Results for Ground Effect Excluding Meteorological Effects  7. Influence of Source Motion on Ground Effect and Diffraction  8. Predicting Effects of Mixed Impedance Ground  9. Predicting the Performance of Outdoor Noise Barriers  10. Predicting Effects of Vegetation, Trees and Turbulence  11. Analytical Approximations including Ground Effect, Refraction and Turbulence  12. Prediction Schemes  13. Predicting Sound in an Urban Environment.

  14. Lung cancer

    International Nuclear Information System (INIS)

    Aisner, J.

    1985-01-01

    This book contains 13 chapters. Some of the chapter titles are: The Pathology of Lung Cancer; Radiotherapy for Non-Small-Cell Cancer of the Lung; Chemotherapy for Non-Small-Cell Lung Cancer; Immunotherapy in the Management of Lung Cancer; Preoperative Staging and Surgery for Non-Small-Cell Lung Cancer; and Prognostic Factors in Lung Cancer

  15. Minimization of Ventilator-Induced Lung Injury in ARDS Patients – Part I: Complex Model of Mechanically Ventilated ARDS Lungs

    Directory of Open Access Journals (Sweden)

    Glapiński Jarosław

    2017-12-01

    Full Text Available A complex model of mechanically ventilated ARDS lungs is proposed in the paper. This analogue is based on a combination of four components that describe breathing mechanics: morphology, mechanical properties of surfactant, tissue and chest wall characteristics. Physical-mathematical formulas attained from experimental data have been translated into their electrical equivalents and implemented in MultiSim software. To examine the adequacy of the forward model to the properties and behaviour of mechanically ventilated lungs in patients with ARDS symptoms, several computer simulations have been performed and reported in the paper. Inhomogeneous characteristics observed in the physical properties of ARDS lungs were mapped in a multi-lobe model and the measured outputs were compared with the data from physiological reports. In this way clinicians and scientists can obtain the knowledge on the moment of airway zone reopening/closure expressed as a function of pressure, volume or even time. In the paper, these trends were assessed for inhomogeneous distributions (proper for ARDS of surfactant properties and airway geometry in consecutive lung lobes. The proposed model enables monitoring of temporal alveolar dynamics in successive lobes as well as those occurring at a higher level of lung structure organization, i.e. in a point P0 which can be used for collection of respiratory data during indirect management of recruitment/de-recruitment processes in ARDS lungs. The complex model and synthetic data generated for various parametrization scenarios make possible prospective studies on designing an indirect mode of alveolar zone management, i.e. with

  16. Sounds of Web Advertising

    DEFF Research Database (Denmark)

    Jessen, Iben Bredahl; Graakjær, Nicolai Jørgensgaard

    2010-01-01

    Sound seems to be a neglected issue in the study of web ads. Web advertising is predominantly regarded as visual phenomena–commercial messages, as for instance banner ads that we watch, read, and eventually click on–but only rarely as something that we listen to. The present chapter presents...... an overview of the auditory dimensions in web advertising: Which kinds of sounds do we hear in web ads? What are the conditions and functions of sound in web ads? Moreover, the chapter proposes a theoretical framework in order to analyse the communicative functions of sound in web advertising. The main...... argument is that an understanding of the auditory dimensions in web advertising must include a reflection on the hypertextual settings of the web ad as well as a perspective on how users engage with web content....

  17. The Aesthetic Experience of Sound

    DEFF Research Database (Denmark)

    Breinbjerg, Morten

    2005-01-01

    to react on. In an ecological understanding of hearing our detection of audible information affords us ways of responding to our environment. In my paper I will address both these ways of using sound in relation to computer games. Since a game player is responsible for the unfolding of the game, his......The use of sound in (3D) computer games basically falls in two. Sound is used as an element in the design of the set and as a narrative. As set design sound stages the nature of the environment, it brings it to life. As a narrative it brings us information that we can choose to or perhaps need...... exploration of the virtual space laid out before him is pertinent. In this mood of exploration sound is important and heavily contributing to the aesthetic of the experience....

  18. Principles of underwater sound

    National Research Council Canada - National Science Library

    Urick, Robert J

    1983-01-01

    ... the immediately useful help they need for sonar problem solving. Its coverage is broad-ranging from the basic concepts of sound in the sea to making performance predictions in such applications as depth sounding, fish finding, and submarine detection...

  19. The mechanical memory of lung myofibroblasts.

    Science.gov (United States)

    Balestrini, Jenna L; Chaudhry, Sidharth; Sarrazy, Vincent; Koehler, Anne; Hinz, Boris

    2012-04-01

    Fibroblasts differentiate into the highly synthetic and contractile myofibroblast phenotype when exposed to substrates with an elastic modulus corresponding to pathologically stiff fibrotic tissue. Cellular responses to changes in substrate stiffness are typically analyzed after hours or days, which does not enable the monitoring of myofibroblast persistence, a hallmark of fibrosis. To determine long-lasting effects on the fibrotic behavior of lung fibroblasts, we followed a novel approach of explanting and repeatedly passaging fibroblasts on silicone substrates with stiffness representing various states of lung health. Fibrotic activity was determined by assaying for myofibroblast proliferation, cell contractility, expression of α-smooth muscle actin, extracellular matrix and active TGFβ1. As predicted, myofibroblast activity was low on healthy soft substrates and increased with increasing substrate stiffness. However, explanting and mechanically priming lung fibroblasts for 3 weeks on pathologically stiff substrates resulted in sustained myofibroblast activity even after the cells were returned to healthy soft cultures for 2 weeks. Such primed cells retained higher fibrotic activity than cells that had been exclusively cultured on soft substrates, and were not statistically different from cells continuously passaged on stiff surfaces. Inversely, priming lung fibroblasts for 3 weeks on soft substrates partially protected from myofibroblast activation after the shift to stiff substrates. Hence, mechano-sensed information relating to physical conditions of the local cellular environment could permanently induce fibrotic behavior of lung fibroblasts. This priming effect has important implications for the progression and persistence of aggressive fibrotic diseases such as idiopathic pulmonary fibrosis. This journal is © The Royal Society of Chemistry 2012

  20. Development of radio acoustic sounding method in Kharkov National University of Radio Electronics

    International Nuclear Information System (INIS)

    Proshkin, Y G; Kartashov, V M; Babkin, S I

    2008-01-01

    The analysis of the role of Kharkov National University of Radio Electronics in developing the atmosphere radio acoustic sounding (RAS) method within the period from 1968 to 2008 was carried out. As a part of the investigation program six experimental models of the sounding radio equipment were developed and manufactured. The atmosphere sounding methods were developed for measuring the base meteorological values. For the first time in the world practice, relevant comparative measurements of air temperature, wind velocity and direction were performed on a short base (about 150 m) using the centimetre RAS equipment and standard sensors of a high (300 m) meteorological mast. The RAS equipment was used for the purpose of meteorological support to investigations in the field of the atmosphere physics and applied problems. All instrumental, atmosphere and social factors, affecting operation the RAS systems, were generalized. It is shown that compact and mobile systems for remote monitoring of the atmospheric boundary layer with possible prompt obtaining of relevant information about base meteorological values in large volumes can be based on the RAS equipment

  1. Sounding the field: recent works in sound studies.

    Science.gov (United States)

    Boon, Tim

    2015-09-01

    For sound studies, the publication of a 593-page handbook, not to mention the establishment of at least one society - the European Sound Studies Association - might seem to signify the emergence of a new academic discipline. Certainly, the books under consideration here, alongside many others, testify to an intensification of concern with the aural dimensions of culture. Some of this work comes from HPS and STS, some from musicology and cultural studies. But all of it should concern members of our disciplines, as it represents a long-overdue foregrounding of the aural in how we think about the intersections of science, technology and culture.

  2. Sound Clocks and Sonic Relativity

    Science.gov (United States)

    Todd, Scott L.; Menicucci, Nicolas C.

    2017-10-01

    Sound propagation within certain non-relativistic condensed matter models obeys a relativistic wave equation despite such systems admitting entirely non-relativistic descriptions. A natural question that arises upon consideration of this is, "do devices exist that will experience the relativity in these systems?" We describe a thought experiment in which `acoustic observers' possess devices called sound clocks that can be connected to form chains. Careful investigation shows that appropriately constructed chains of stationary and moving sound clocks are perceived by observers on the other chain as undergoing the relativistic phenomena of length contraction and time dilation by the Lorentz factor, γ , with c the speed of sound. Sound clocks within moving chains actually tick less frequently than stationary ones and must be separated by a shorter distance than when stationary to satisfy simultaneity conditions. Stationary sound clocks appear to be length contracted and time dilated to moving observers due to their misunderstanding of their own state of motion with respect to the laboratory. Observers restricted to using sound clocks describe a universe kinematically consistent with the theory of special relativity, despite the preferred frame of their universe in the laboratory. Such devices show promise in further probing analogue relativity models, for example in investigating phenomena that require careful consideration of the proper time elapsed for observers.

  3. Non-Wovens as Sound Reducers

    Science.gov (United States)

    Belakova, D.; Seile, A.; Kukle, S.; Plamus, T.

    2018-04-01

    Within the present study, the effect of hemp (40 wt%) and polyactide (60 wt%), non-woven surface density, thickness and number of fibre web layers on the sound absorption coefficient and the sound transmission loss in the frequency range from 50 to 5000 Hz is analysed. The sound insulation properties of the experimental samples have been determined, compared to the ones in practical use, and the possible use of material has been defined. Non-woven materials are ideally suited for use in acoustic insulation products because the arrangement of fibres produces a porous material structure, which leads to a greater interaction between sound waves and fibre structure. Of all the tested samples (A, B and D), the non-woven variant B exceeded the surface density of sample A by 1.22 times and 1.15 times that of sample D. By placing non-wovens one above the other in 2 layers, it is possible to increase the absorption coefficient of the material, which depending on the frequency corresponds to C, D, and E sound absorption classes. Sample A demonstrates the best sound absorption of all the three samples in the frequency range from 250 to 2000 Hz. In the test frequency range from 50 to 5000 Hz, the sound transmission loss varies from 0.76 (Sample D at 63 Hz) to 3.90 (Sample B at 5000 Hz).

  4. Sounds of Space

    Science.gov (United States)

    Gurnett, D. A.

    2005-12-01

    Starting in the early 1960s, spacecraft-borne plasma wave instruments revealed that space is filled with an astonishing variety of radio and plasma wave sounds, which have come to be called "sounds of space." For over forty years these sounds have been collected and played to a wide variety of audiences, often as the result of press conferences or press releases involving various NASA projects for which the University of Iowa has provided plasma wave instruments. This activity has led to many interviews on local and national radio programs, and occasionally on programs haviang world-wide coverage, such as the BBC. As a result of this media coverage, we have been approached many times by composers requesting copies of our space sounds for use in their various projects, many of which involve electronic synthesis of music. One of these collaborations led to "Sun Rings," which is a musical event produced by the Kronos Quartet that has played to large audiences all over the world. With the availability of modern computer graphic techniques we have recently been attempting to integrate some of these sound of space into an educational audio/video web site that illustrates the scientific principles involved in the origin of space plasma waves. Typically I try to emphasize that a substantial gas pressure exists everywhere in space in the form of an ionized gas called a plasma, and that this plasma can lead to a wide variety of wave phenomenon. Examples of some of this audio/video material will be presented.

  5. Sound Synthesis and Evaluation of Interactive Footsteps and Environmental Sounds Rendering for Virtual Reality Applications

    DEFF Research Database (Denmark)

    Nordahl, Rolf; Turchet, Luca; Serafin, Stefania

    2011-01-01

    We propose a system that affords real-time sound synthesis of footsteps on different materials. The system is based on microphones, which detect real footstep sounds from subjects, from which the ground reaction force (GRF) is estimated. Such GRF is used to control a sound synthesis engine based ...... a soundscape significantly improves the recognition of the simulated environment....

  6. Risk factors for radiation pneumonitis after stereotactic radiation therapy for lung tumours: clinical usefulness of the planning target volume to total lung volume ratio.

    Science.gov (United States)

    Ueyama, Tomoko; Arimura, Takeshi; Takumi, Koji; Nakamura, Fumihiko; Higashi, Ryutaro; Ito, Soichiro; Fukukura, Yoshihiko; Umanodan, Tomokazu; Nakajo, Masanori; Koriyama, Chihaya; Yoshiura, Takashi

    2018-06-01

    To identify risk factors for symptomatic radiation pneumonitis (RP) after stereotactic radiation therapy (SRT) for lung tumours. We retrospectively evaluated 68 lung tumours in 63 patients treated with SRT between 2011 and 2015. RP was graded according to the National Cancer Institute-Common Terminology Criteria for Adverse Events version 4.0. SRT was delivered at 7.0-12.0 Gy per each fraction, once daily, to a total of 48-64 Gy (median, 50 Gy). Univariate analysis was performed to assess patient- and treatment-related factors, including age, sex, smoking index (SI), pulmonary function, tumour location, serum Krebs von den Lungen-6 value (KL-6), dose-volume metrics (V5, V10, V20, V30, V40 and VS5), homogeneity index of the planning target volume (PTV), PTV dose, mean lung dose (MLD), contralateral MLD and V2, PTV volume, lung volume and the PTV/lung volume ratio (PTV/Lung). Performance of PTV/Lung in predicting symptomatic RP was also analysed using receiver operating characteristic (ROC) analysis. The median follow-up period was 21 months. 10 of 63 patients (15.9%) developed symptomatic RP after SRT. On univariate analysis, V10, V20, PTV volume and PTV/Lung were significantly associated with occurrence of RP  ≥Grade 2. ROC curves indicated that symptomatic RP could be predicted using PTV/Lung [area under curve (AUC): 0.88, confidence interval (CI: 0.78-0.95), cut-off value: 1.09, sensitivity: 90.0% and specificity: 72.4%]. PTV/Lung is a good predictor of symptomatic RP after SRT. Advances in knowledge: The cases with high PTV/Lung should be carefully monitored with caution for the occurrence of RP after SRT.

  7. Using therapeutic sound with progressive audiologic tinnitus management.

    Science.gov (United States)

    Henry, James A; Zaugg, Tara L; Myers, Paula J; Schechter, Martin A

    2008-09-01

    Management of tinnitus generally involves educational counseling, stress reduction, and/or the use of therapeutic sound. This article focuses on therapeutic sound, which can involve three objectives: (a) producing a sense of relief from tinnitus-associated stress (using soothing sound); (b) passively diverting attention away from tinnitus by reducing contrast between tinnitus and the acoustic environment (using background sound); and (c) actively diverting attention away from tinnitus (using interesting sound). Each of these goals can be accomplished using three different types of sound-broadly categorized as environmental sound, music, and speech-resulting in nine combinations of uses of sound and types of sound to manage tinnitus. The authors explain the uses and types of sound, how they can be combined, and how the different combinations are used with Progressive Audiologic Tinnitus Management. They also describe how sound is used with other sound-based methods of tinnitus management (Tinnitus Masking, Tinnitus Retraining Therapy, and Neuromonics).

  8. Letter-Sound Knowledge: Exploring Gender Differences in Children When They Start School Regarding Knowledge of Large Letters, Small Letters, Sound Large Letters, and Sound Small Letters

    Directory of Open Access Journals (Sweden)

    Hermundur Sigmundsson

    2017-09-01

    Full Text Available This study explored whether there is a gender difference in letter-sound knowledge when children start at school. 485 children aged 5–6 years completed assessment of letter-sound knowledge, i.e., large letters; sound of large letters; small letters; sound of small letters. The findings indicate a significant difference between girls and boys in all four factors tested in this study in favor of the girls. There are still no clear explanations to the basis of a presumed gender difference in letter-sound knowledge. That the findings have origin in neuro-biological factors cannot be excluded, however, the fact that girls probably have been exposed to more language experience/stimulation compared to boys, lends support to explanations derived from environmental aspects.

  9. Sound card based digital correlation detection of weak photoelectrical signals

    International Nuclear Information System (INIS)

    Tang Guanghui; Wang Jiangcheng

    2005-01-01

    A simple and low-cost digital correlation method is proposed to investigate weak photoelectrical signals, using a high-speed photodiode as detector, which is directly connected to a programmably triggered sound card analogue-to-digital converter and a personal computer. Two testing experiments, autocorrelation detection of weak flickering signals from a computer monitor under background of noisy outdoor stray light and cross-correlation measurement of the surface velocity of a motional tape, are performed, showing that the results are reliable and the method is easy to implement

  10. By the sound of it. An ERP investigation of human action sound processing in 7-month-old infants

    Directory of Open Access Journals (Sweden)

    Elena Geangu

    2015-04-01

    Full Text Available Recent evidence suggests that human adults perceive human action sounds as a distinct category from human vocalizations, environmental, and mechanical sounds, activating different neural networks (Engel et al., 2009; Lewis et al., 2011. Yet, little is known about the development of such specialization. Using event-related potentials (ERP, this study investigated neural correlates of 7-month-olds’ processing of human action (HA sounds in comparison to human vocalizations (HV, environmental (ENV, and mechanical (MEC sounds. Relative to the other categories, HA sounds led to increased positive amplitudes between 470 and 570 ms post-stimulus onset at left anterior temporal locations, while HV led to increased negative amplitudes at the more posterior temporal locations in both hemispheres. Collectively, human produced sounds (HA + HV led to significantly different response profiles compared to non-living sound sources (ENV + MEC at parietal and frontal locations in both hemispheres. Overall, by 7 months of age human action sounds are being differentially processed in the brain, consistent with a dichotomy for processing living versus non-living things. This provides novel evidence regarding the typical categorical processing of socially relevant sounds.

  11. Interplay between the lung microbiome and lung cancer.

    Science.gov (United States)

    Mao, Qixing; Jiang, Feng; Yin, Rong; Wang, Jie; Xia, Wenjie; Dong, Gaochao; Ma, Weidong; Yang, Yao; Xu, Lin; Hu, Jianzhong

    2018-02-28

    The human microbiome confers benefits or disease susceptibility to the human body through multiple pathways. Disruption of the symbiotic balance of the human microbiome is commonly found in systematic diseases such as diabetes, obesity, and chronic gastric diseases. Emerging evidence has suggested that dysbiosis of the microbiota may also play vital roles in carcinogenesis at multiple levels, e.g., by affecting metabolic, inflammatory, or immune pathways. Although the impact of the gut microbiome on the digestive cancer has been widely explored, few studies have investigated the interplay between the microbiome and lung cancer. Some recent studies have shown that certain microbes and microbiota dysbiosis are correlated with development of lung cancer. In this mini-review, we briefly summarize current research findings describing the relationship between the lung microbiome and lung cancer. We further discuss the potential mechanisms through which the lung microbiome may play a role in lung carcinogenesis and impact lung cancer treatment. A better knowledge of the interplay between the lung microbiome and lung cancer may promote the development of innovative strategies for early prevention and personalized treatment in lung cancer. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Fourth sound in relativistic superfluidity theory

    International Nuclear Information System (INIS)

    Vil'chinskij, S.I.; Fomin, P.I.

    1995-01-01

    The Lorentz-covariant equations describing propagation of the fourth sound in the relativistic theory of superfluidity are derived. The expressions for the velocity of the fourth sound are obtained. The character of oscillation in sound is determined

  13. The science of sound recording

    CERN Document Server

    Kadis, Jay

    2012-01-01

    The Science of Sound Recording will provide you with more than just an introduction to sound and recording, it will allow you to dive right into some of the technical areas that often appear overwhelming to anyone without an electrical engineering or physics background.  The Science of Sound Recording helps you build a basic foundation of scientific principles, explaining how recording really works. Packed with valuable must know information, illustrations and examples of 'worked through' equations this book introduces the theory behind sound recording practices in a logical and prac

  14. Lung cells support osteosarcoma cell migration and survival.

    Science.gov (United States)

    Yu, Shibing; Fourman, Mitchell Stephen; Mahjoub, Adel; Mandell, Jonathan Brendan; Crasto, Jared Anthony; Greco, Nicholas Giuseppe; Weiss, Kurt Richard

    2017-01-25

    phosphatase staining. Lung endothelial HULEC-5a cells are attractants for OS cell migration, proliferation, and survival. The SJSA-1 osteosarcoma cell line demonstrated greater metastatic potential than Saos-2 and U-2 cells. ALDH appears to be involved in the interaction between lung and OS cells, and ALP may be a valuable biomarker for monitoring functional OS changes during metastasis.

  15. Nuclear sound

    International Nuclear Information System (INIS)

    Wambach, J.

    1991-01-01

    Nuclei, like more familiar mechanical systems, undergo simple vibrational motion. Among these vibrations, sound modes are of particular interest since they reveal important information on the effective interactions among the constituents and, through extrapolation, on the bulk behaviour of nuclear and neutron matter. Sound wave propagation in nuclei shows strong quantum effects familiar from other quantum systems. Microscopic theory suggests that the restoring forces are caused by the complex structure of the many-Fermion wavefunction and, in some cases, have no classical analogue. The damping of the vibrational amplitude is strongly influenced by phase coherence among the particles participating in the motion. (author)

  16. Non-invasive gas monitoring in newborn infants using diode laser absorption spectroscopy: a case study

    Science.gov (United States)

    Lundin, Patrik; Svanberg, Emilie K.; Cocola, Lorenzo; Lewander, Märta; Andersson-Engels, Stefan; Jahr, John; Fellman, Vineta; Svanberg, Katarina; Svanberg, Sune

    2012-03-01

    Non-invasive diode laser spectroscopy was, for the first time, used to assess gas content in the intestines and the lungs of a new-born, 4 kg, baby. Two gases, water vapor and oxygen, were studied with two low-power tunable diode lasers, illuminating the surface skin tissue and detecting the diffusely emerging light a few centimeters away. The light, having penetrated into the tissue, had experienced absorption by gas located in the lungs and in the intestines. Very distinct water vapor signals were obtained from the intestines while imprint from oxygen was lacking, as expected. Detectable, but minor, signals of water vapor were also obtained from the lungs, illuminating the armpit area and detecting below the collar bone. Water vapor signals were seen but again oxygen signals were lacking, now due to the difficulties of penetration of the oxygen probing light into the lungs of this full-term baby. Ultra-sound images were obtained both from the lungs and from the stomach of the baby. Based on dimensions and our experimental findings, we conclude, that for early pre-term babies, also oxygen should be detectable in the lungs, in addition to intestine and lung detection of water vapor. The present paper focuses on the studies of the intestines while the lung studies will be covered in a forthcoming paper.

  17. Uniform background assumption produces misleading lung EIT images.

    Science.gov (United States)

    Grychtol, Bartłomiej; Adler, Andy

    2013-06-01

    Electrical impedance tomography (EIT) estimates an image of conductivity change within a body from stimulation and measurement at body surface electrodes. There is significant interest in EIT for imaging the thorax, as a monitoring tool for lung ventilation. To be useful in this application, we require an understanding of if and when EIT images can produce inaccurate images. In this paper, we study the consequences of the homogeneous background assumption, frequently made in linear image reconstruction, which introduces a mismatch between the reference measurement and the linearization point. We show in simulation and experimental data that the resulting images may contain large and clinically significant errors. A 3D finite element model of thorax conductivity is used to simulate EIT measurements for different heart and lung conductivity, size and position, as well as different amounts of gravitational collapse and ventilation-associated conductivity change. Three common linear EIT reconstruction algorithms are studied. We find that the asymmetric position of the heart can cause EIT images of ventilation to show up to 60% undue bias towards the left lung and that the effect is particularly strong for a ventilation distribution typical of mechanically ventilated patients. The conductivity gradient associated with gravitational lung collapse causes conductivity changes in non-dependent lung to be overestimated by up to 100% with respect to the dependent lung. Eliminating the mismatch by using a realistic conductivity distribution in the forward model of the reconstruction algorithm strongly reduces these undesirable effects. We conclude that subject-specific anatomically accurate forward models should be used in lung EIT and extra care is required when analysing EIT images of subjects whose background conductivity distribution in the lungs is known to be heterogeneous or exhibiting large changes.

  18. Uniform background assumption produces misleading lung EIT images

    International Nuclear Information System (INIS)

    Grychtol, Bartłomiej; Adler, Andy

    2013-01-01

    Electrical impedance tomography (EIT) estimates an image of conductivity change within a body from stimulation and measurement at body surface electrodes. There is significant interest in EIT for imaging the thorax, as a monitoring tool for lung ventilation. To be useful in this application, we require an understanding of if and when EIT images can produce inaccurate images. In this paper, we study the consequences of the homogeneous background assumption, frequently made in linear image reconstruction, which introduces a mismatch between the reference measurement and the linearization point. We show in simulation and experimental data that the resulting images may contain large and clinically significant errors. A 3D finite element model of thorax conductivity is used to simulate EIT measurements for different heart and lung conductivity, size and position, as well as different amounts of gravitational collapse and ventilation-associated conductivity change. Three common linear EIT reconstruction algorithms are studied. We find that the asymmetric position of the heart can cause EIT images of ventilation to show up to 60% undue bias towards the left lung and that the effect is particularly strong for a ventilation distribution typical of mechanically ventilated patients. The conductivity gradient associated with gravitational lung collapse causes conductivity changes in non-dependent lung to be overestimated by up to 100% with respect to the dependent lung. Eliminating the mismatch by using a realistic conductivity distribution in the forward model of the reconstruction algorithm strongly reduces these undesirable effects. We conclude that subject-specific anatomically accurate forward models should be used in lung EIT and extra care is required when analysing EIT images of subjects whose background conductivity distribution in the lungs is known to be heterogeneous or exhibiting large changes. (paper)

  19. Pipeline monitoring using acoustic principal component analysis recognition with the Mel scale

    International Nuclear Information System (INIS)

    Wan, Chunfeng; Mita, Akira

    2009-01-01

    In modern cities, many important pipelines are laid underground. In order to prevent these lifeline infrastructures from accidental damage, monitoring systems are becoming indispensable. Third party activities were shown by recent reports to be a major cause of pipeline damage. Potential damage threat to the pipeline can be identified by detecting dangerous construction equipment nearby by studying the surrounding noise. Sound recognition technologies are used to identify them by their sounds, which can easily be captured by small sensors deployed along the pipelines. Pattern classification methods based on principal component analysis (PCA) were used to recognize the sounds from road cutters. In this paper, a Mel residual, i.e. the PCA residual in the Mel scale, is proposed to be the recognition feature. Determining if a captured sound belongs to a road cutter only requires checking how large its Mel residual is. Experiments were conducted and results showed that the proposed Mel-residual-based PCA recognition worked very well. The proposed Mel PCA residual recognition method will be very useful for pipeline monitoring systems to prevent accidental breakage and to ensure the safety of underground lifeline infrastructures

  20. Students' Learning of a Generalized Theory of Sound Transmission from a Teaching-Learning Sequence about Sound, Hearing and Health

    Science.gov (United States)

    West, Eva; Wallin, Anita

    2013-04-01

    Learning abstract concepts such as sound often involves an ontological shift because to conceptualize sound transmission as a process of motion demands abandoning sound transmission as a transfer of matter. Thus, for students to be able to grasp and use a generalized model of sound transmission poses great challenges for them. This study involved 199 students aged 10-14. Their views about sound transmission were investigated before and after teaching by comparing their written answers about sound transfer in different media. The teaching was built on a research-based teaching-learning sequence (TLS), which was developed within a framework of design research. The analysis involved interpreting students' underlying theories of sound transmission, including the different conceptual categories that were found in their answers. The results indicated a shift in students' understandings from the use of a theory of matter before the intervention to embracing a theory of process afterwards. The described pattern was found in all groups of students irrespective of age. Thus, teaching about sound and sound transmission is fruitful already at the ages of 10-11. However, the older the students, the more advanced is their understanding of the process of motion. In conclusion, the use of a TLS about sound, hearing and auditory health promotes students' conceptualization of sound transmission as a process in all grades. The results also imply some crucial points in teaching and learning about the scientific content of sound.

  1. Digitizing a sound archive

    DEFF Research Database (Denmark)

    Cone, Louise

    2017-01-01

    Danish and international artists. His methodology left us with a large collection of unique and inspirational time-based media sound artworks that have, until very recently, been inaccessible. Existing on an array of different media formats, such as open reel tapes, 8-track and 4 track cassettes, VHS......In 1990 an artist by the name of William Louis Sørensen was hired by the National Gallery of Denmark to collect important works of art – made from sound. His job was to acquire sound art, but also recordings that captured rare artistic occurrences, music, performances and happenings from both...

  2. Adaptive Wavelet Threshold Denoising Method for Machinery Sound Based on Improved Fruit Fly Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Jing Xu

    2016-07-01

    Full Text Available As the sound signal of a machine contains abundant information and is easy to measure, acoustic-based monitoring or diagnosis systems exhibit obvious superiority, especially in some extreme conditions. However, the sound directly collected from industrial field is always polluted. In order to eliminate noise components from machinery sound, a wavelet threshold denoising method optimized by an improved fruit fly optimization algorithm (WTD-IFOA is proposed in this paper. The sound is firstly decomposed by wavelet transform (WT to obtain coefficients of each level. As the wavelet threshold functions proposed by Donoho were discontinuous, many modified functions with continuous first and second order derivative were presented to realize adaptively denoising. However, the function-based denoising process is time-consuming and it is difficult to find optimal thresholds. To overcome these problems, fruit fly optimization algorithm (FOA was introduced to the process. Moreover, to avoid falling into local extremes, an improved fly distance range obeying normal distribution was proposed on the basis of original FOA. Then, sound signal of a motor was recorded in a soundproof laboratory, and Gauss white noise was added into the signal. The simulation results illustrated the effectiveness and superiority of the proposed approach by a comprehensive comparison among five typical methods. Finally, an industrial application on a shearer in coal mining working face was performed to demonstrate the practical effect.

  3. Selected trends in lung cancer epidemiology in Slovakia

    International Nuclear Information System (INIS)

    Ondrusova, M.; Psenkova, M.; Berzinec, P.

    2015-01-01

    Introduction: The lung cancer is still among the dominant malignant tumors despite declining trend of incidence, especially in men, and also its adverse prognosis remains. Aim: The aim of the study was to analyse the development of long-term trends in incidence and mortality and to produce a prospective estimate of prevalence and overall burden of lung cancer in the population in the Slovak Republic. Results: A significant drop of incidence of the disease in men has been seen in Slovakia since 1988 by a mean annual percentage change of -2.16%, whereby mortality is declining a little faster (by an annual percentage change of -2.87%). Adverse trend has been registered in both indicators in case of lung cancer in women, with incidence rising since 2001 by 5.31% annually and mortality rising by 1.3% for the whole monitored period. Conclusion: The adverse rising trend in the incidence and mortality of lung cancer in women in the Slovak Republic, as well as the slower decline in incidence and mortality in men compared with some countries of Western Europe, will have an impact in future also on total costs for management of this disease. (author)

  4. Parallel-plate third sound waveguides with fixed and variable plate spacings for the study of fifth sound in superfluid helium

    International Nuclear Information System (INIS)

    Jelatis, G.J.

    1983-01-01

    Third sound in superfluid helium four films has been investigated using two parallel-plate waveguides. These investigations led to the observation of fifth sound, a new mode of sound propagation. Both waveguides consisted of two parallel pieces of vitreous quartz. The sound speed was obtained by measuring the time-of-flight of pulsed third sound over a known distance. Investigations from 1.0-1.7K were possible with the use of superconducting bolometers, which measure the temperature component of the third sound wave. Observations were initially made with a waveguide having a plate separation fixed at five microns. Adiabatic third sound was measured in the geometry. Isothermal third sound was also observed, using the usual, single-substrate technique. Fifth sound speeds, calculated from the two-fluid theory of helium and the speeds of the two forms of third sound, agreed in size and temperature dependence with theoretical predictions. Nevertheless, only equivocal observations of fifth sound were made. As a result, the film-substrate interaction was examined, and estimates of the Kapitza conductance were made. Assuming the dominance of the effects of this conductance over those due to the ECEs led to a new expression for fifth sound. A reanalysis of the initial data was made, which contained no adjustable parameters. The observation of fifth sound was seen to be consistent with the existence of an anomalously low boundary conductance

  5. Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals

    Directory of Open Access Journals (Sweden)

    Rong-Chao Peng

    2015-09-01

    Full Text Available Cardiovascular disease, like hypertension, is one of the top killers of human life and early detection of cardiovascular disease is of great importance. However, traditional medical devices are often bulky and expensive, and unsuitable for home healthcare. In this paper, we proposed an easy and inexpensive technique to estimate continuous blood pressure from the heart sound signals acquired by the microphone of a smartphone. A cold-pressor experiment was performed in 32 healthy subjects, with a smartphone to acquire heart sound signals and with a commercial device to measure continuous blood pressure. The Fourier spectrum of the second heart sound and the blood pressure were regressed using a support vector machine, and the accuracy of the regression was evaluated using 10-fold cross-validation. Statistical analysis showed that the mean correlation coefficients between the predicted values from the regression model and the measured values from the commercial device were 0.707, 0.712, and 0.748 for systolic, diastolic, and mean blood pressure, respectively, and that the mean errors were less than 5 mmHg, with standard deviations less than 8 mmHg. These results suggest that this technique is of potential use for cuffless and continuous blood pressure monitoring and it has promising application in home healthcare services.

  6. Sound propagation in cities

    NARCIS (Netherlands)

    Salomons, E.; Polinder, H.; Lohman, W.; Zhou, H.; Borst, H.

    2009-01-01

    A new engineering model for sound propagation in cities is presented. The model is based on numerical and experimental studies of sound propagation between street canyons. Multiple reflections in the source canyon and the receiver canyon are taken into account in an efficient way, while weak

  7. Hamiltonian Algorithm Sound Synthesis

    OpenAIRE

    大矢, 健一

    2013-01-01

    Hamiltonian Algorithm (HA) is an algorithm for searching solutions is optimization problems. This paper introduces a sound synthesis technique using Hamiltonian Algorithm and shows a simple example. "Hamiltonian Algorithm Sound Synthesis" uses phase transition effect in HA. Because of this transition effect, totally new waveforms are produced.

  8. Exploring Noise: Sound Pollution.

    Science.gov (United States)

    Rillo, Thomas J.

    1979-01-01

    Part one of a three-part series about noise pollution and its effects on humans. This section presents the background information for teachers who are preparing a unit on sound. The next issues will offer learning activities for measuring the effects of sound and some references. (SA)

  9. Improved air trapping evaluation in chest computed tomography in children with cystic fibrosis using real-time spirometric monitoring and biofeedback.

    Science.gov (United States)

    Kongstad, Thomas; Buchvald, Frederik F; Green, Kent; Lindblad, Anders; Robinson, Terry E; Nielsen, Kim G

    2013-12-01

    The quality of chest Computed Tomography (CT) images in children is dependent upon a sufficient breath hold during CT scanning. This study evaluates the influence of spirometric breath hold monitoring with biofeedback software on inspiratory and expiratory chest CT lung density measures, and on trapped air (TA) scoring in children with cystic fibrosis (CF). This is important because TA is an important component of early and progressive CF lung disease. A cross sectional comparison study was completed for chest CT imaging in two cohorts of CF children with comparable disease severity, using spirometric breath hold monitoring and biofeedback software (Copenhagen (COP)) or unmonitored breath hold manoeuvres (Gothenburg (GOT)). Inspiratory-expiratory lung density differences were calculated, and TA was scored to assess the difference between the two cohorts. Eighty-four chest CTs were evaluated. Mean (95%CI) change in inspiratory-expiratory lung density differences was 436 Hounsfield Units (HU) (408 to 464) in the COP cohort with spirometric breath hold monitoring versus 229 HU (188 to 269) in the GOT cohort with unmonitored breath hold manoeuvres (pchildren with comparable CF lung disease, spirometric breath hold monitoring during examination yielded a large difference in lung volume between inhalation and exhalation, and allowed for a significantly greater measured change in lung density and TA score, compared to unmonitored breath hold maneuvers. This has implications to the clinical use of chest CT, especially in children with early CF lung disease. Copyright © 2013 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  10. Photoacoustic Sounds from Meteors.

    Energy Technology Data Exchange (ETDEWEB)

    Spalding, Richard E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Tencer, John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sweatt, William C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hogan, Roy E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Boslough, Mark B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Spurny, Pavel [Academy of Sciences of the Czech Republic (ASCR), Prague (Czech Republic)

    2015-03-01

    High-speed photometric observations of meteor fireballs have shown that they often produce high-amplitude light oscillations with frequency components in the kHz range, and in some cases exhibit strong millisecond flares. We built a light source with similar characteristics and illuminated various materials in the laboratory, generating audible sounds. Models suggest that light oscillations and pulses can radiatively heat dielectric materials, which in turn conductively heats the surrounding air on millisecond timescales. The sound waves can be heard if the illuminated material is sufficiently close to the observer’s ears. The mechanism described herein may explain many reports of meteors that appear to be audible while they are concurrently visible in the sky and too far away for sound to have propagated to the observer. This photoacoustic (PA) explanation provides an alternative to electrophonic (EP) sounds hypothesized to arise from electromagnetic coupling of plasma oscillation in the meteor wake to natural antennas in the vicinity of an observer.

  11. Urban Sound Interfaces

    DEFF Research Database (Denmark)

    Breinbjerg, Morten

    2012-01-01

    This paper draws on the theories of Michel de Certeau and Gaston Bachelard to discuss how media architecture, in the form of urban sound interfaces, can help us perceive the complexity of the spaces we inhabit, by exploring the history and the narratives of the places in which we live. In this pa......This paper draws on the theories of Michel de Certeau and Gaston Bachelard to discuss how media architecture, in the form of urban sound interfaces, can help us perceive the complexity of the spaces we inhabit, by exploring the history and the narratives of the places in which we live....... In this paper, three sound works are discussed in relation to the iPod, which is considered as a more private way to explore urban environments, and as a way to control the individual perception of urban spaces....

  12. Sound field separation with sound pressure and particle velocity measurements

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren; Jacobsen, Finn; Leclère, Quentin

    2012-01-01

    separation techniques make it possible to distinguish between outgoing and incoming waves from the two sides, and thus NAH can be applied. In this paper, a separation method based on the measurement of the particle velocity in two layers and another method based on the measurement of the pressure...... and the velocity in a single layer are proposed. The two methods use an equivalent source formulation with separate transfer matrices for the outgoing and incoming waves, so that the sound from the two sides of the array can be modeled independently. A weighting scheme is proposed to account for the distance......In conventional near-field acoustic holography (NAH) it is not possible to distinguish between sound from the two sides of the array, thus, it is a requirement that all the sources are confined to only one side and radiate into a free field. When this requirement cannot be fulfilled, sound field...

  13. Electromagnetic sounding of the Earth's interior

    CERN Document Server

    Spichak, Viacheslav V

    2015-01-01

    Electromagnetic Sounding of the Earth's Interior 2nd edition provides a comprehensive up-to-date collection of contributions, covering methodological, computational and practical aspects of Electromagnetic sounding of the Earth by different techniques at global, regional and local scales. Moreover, it contains new developments such as the concept of self-consistent tasks of geophysics and , 3-D interpretation of the TEM sounding which, so far, have not all been covered by one book. Electromagnetic Sounding of the Earth's Interior 2nd edition consists of three parts: I- EM sounding methods, II- Forward modelling and inversion techniques, and III - Data processing, analysis, modelling and interpretation. The new edition includes brand new chapters on Pulse and frequency electromagnetic sounding for hydrocarbon offshore exploration. Additionally all other chapters have been extensively updated to include new developments. Presents recently developed methodological findings of the earth's study, including seism...

  14. 21 CFR 876.4590 - Interlocking urethral sound.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Interlocking urethral sound. 876.4590 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4590 Interlocking urethral sound. (a) Identification. An interlocking urethral sound is a device that consists of two metal sounds...

  15. LungMAP: The Molecular Atlas of Lung Development Program.

    Science.gov (United States)

    Ardini-Poleske, Maryanne E; Clark, Robert F; Ansong, Charles; Carson, James P; Corley, Richard A; Deutsch, Gail H; Hagood, James S; Kaminski, Naftali; Mariani, Thomas J; Potter, Steven S; Pryhuber, Gloria S; Warburton, David; Whitsett, Jeffrey A; Palmer, Scott M; Ambalavanan, Namasivayam

    2017-11-01

    The National Heart, Lung, and Blood Institute is funding an effort to create a molecular atlas of the developing lung (LungMAP) to serve as a research resource and public education tool. The lung is a complex organ with lengthy development time driven by interactive gene networks and dynamic cross talk among multiple cell types to control and coordinate lineage specification, cell proliferation, differentiation, migration, morphogenesis, and injury repair. A better understanding of the processes that regulate lung development, particularly alveologenesis, will have a significant impact on survival rates for premature infants born with incomplete lung development and will facilitate lung injury repair and regeneration in adults. A consortium of four research centers, a data coordinating center, and a human tissue repository provides high-quality molecular data of developing human and mouse lungs. LungMAP includes mouse and human data for cross correlation of developmental processes across species. LungMAP is generating foundational data and analysis, creating a web portal for presentation of results and public sharing of data sets, establishing a repository of young human lung tissues obtained through organ donor organizations, and developing a comprehensive lung ontology that incorporates the latest findings of the consortium. The LungMAP website (www.lungmap.net) currently contains more than 6,000 high-resolution lung images and transcriptomic, proteomic, and lipidomic human and mouse data and provides scientific information to stimulate interest in research careers for young audiences. This paper presents a brief description of research conducted by the consortium, database, and portal development and upcoming features that will enhance the LungMAP experience for a community of users. Copyright © 2017 the American Physiological Society.

  16. Poetry Pages. Sound Effects.

    Science.gov (United States)

    Fina, Allan de

    1992-01-01

    Explains how elementary teachers can help students understand onomatopoeia, suggesting that they define onomatopoeia, share examples of it, read poems and have students discuss onomatopoeic words, act out common household sounds, write about sound effects, and create choral readings of onomatopoeic poems. Two appropriate poems are included. (SM)

  17. Mobile sound: media art in hybrid spaces

    OpenAIRE

    Behrendt, Frauke

    2010-01-01

    The thesis explores the relationships between sound and mobility through an examination\\ud of sound art. The research engages with the intersection of sound, mobility and\\ud art through original empirical work and theoretically through a critical engagement with\\ud sound studies. In dialogue with the work of De Certeau, Lefebvre, Huhtamo and Habermas\\ud in terms of the poetics of walking, rhythms, media archeology and questions of\\ud publicness, I understand sound art as an experimental mobil...

  18. Sound source measurement by using a passive sound insulation and a statistical approach

    Science.gov (United States)

    Dragonetti, Raffaele; Di Filippo, Sabato; Mercogliano, Francesco; Romano, Rosario A.

    2015-10-01

    This paper describes a measurement technique developed by the authors that allows carrying out acoustic measurements inside noisy environments reducing background noise effects. The proposed method is based on the integration of a traditional passive noise insulation system with a statistical approach. The latter is applied to signals picked up by usual sensors (microphones and accelerometers) equipping the passive sound insulation system. The statistical approach allows improving of the sound insulation given only by the passive sound insulation system at low frequency. The developed measurement technique has been validated by means of numerical simulations and measurements carried out inside a real noisy environment. For the case-studies here reported, an average improvement of about 10 dB has been obtained in a frequency range up to about 250 Hz. Considerations on the lower sound pressure level that can be measured by applying the proposed method and the measurement error related to its application are reported as well.

  19. Monitor Infrastructure and Space 2012. Baseline; Monitor Infrastructuur en Ruimte 2012. Nulmeting

    Energy Technology Data Exchange (ETDEWEB)

    Kuiper, R.; Van der Schuit, J. [Planbureau voor de Leefomgeving PBL, Den Haag (Netherlands)

    2012-09-15

    What about the competitiveness of the Netherlands? Does the accessibility improve? Is the environment safe and sound? This Monitor shows the extent to which the goals of the Vision on Infrastructure and Spatial Planning (SVIR) are reached. The monitor contains indicators for thirteen national interests from the SVIR, the essential components of the Mobility Memorandum (2004) as included in the SVIR, and for some of the 'released' goals of the National Spatial Strategy (2006). This monitor contains the first measurement (baseline) of the indicators. The first follow-up survey is planned in 2014 [Dutch] Hoe staat het met de concurrentiekracht van Nederland? Verbetert de bereikbaarheid? Is de omgeving leefbaar en veilig? De Monitor Infrastructuur en Ruimte laat zien in hoeverre deze doelen uit de Structuurvisie Infrastructuur en Ruimte (SVIR) worden bereikt. De monitor bevat indicatoren voor de dertien nationale belangen uit de SVIR, de essentiele onderdelen van de Nota Mobiliteit (2004) zoals opgenomen in de SVIR, en voor enkele van de 'losgelaten' doelen uit de Nota Ruimte (2006). Deze monitor bevat de eerste meting (nulmeting) van de indicatoren. De eerste vervolgmeting is gepland in 2014.

  20. Film sound in preservation and presentation

    NARCIS (Netherlands)

    Campanini, S.

    2014-01-01

    What is the nature of film sound? How does it change through time? How can film sound be conceptually defined? To address these issues, this work assumes the perspective of film preservation and presentation practices, describing the preservation of early sound systems, as well as the presentation

  1. Acceptance and Use of Mobile Technology for Health Self-Monitoring in Lung Transplant Recipients during the First Year Post-Transplantation.

    Science.gov (United States)

    Jiang, Yun; Sereika, Susan M; Dabbs, Annette DeVito; Handler, Steven M; Schlenk, Elizabeth A

    2016-01-01

    To describe lung transplant recipients (LTRs') acceptance and use of mobile technology for health self-monitoring during the first year post-transplantation, and explore correlates of the use of technology in the 0 to 2, >2 to ≤6, >6 to ≤12, and 0 to 12 months. Secondary analysis of data from 96 LTR assigned to use Pocket PATH(®), a smartphone application, for daily health self-monitoring in a randomized controlled trial. Use of Pocket PATH was categorized as low, moderate, and high use. Proportional odds models for ordinal logistic regression were employed to explore correlates of use of technology. LTR reported high acceptance of Pocket PATH at baseline. However, acceptance was not associated with actual use over the 12 months (p=0.45~0.96). Actual use decreased across time intervals (ptechnology training (p=0.02) in the first 2 months. Higher use from >2 to ≤6 months was associated with greater satisfaction with technology training (OR=3.37, p=0.01) and shorter length of hospital stay (OR=0.98, p=0.02). Higher use from >6 to ≤12 months was associated with older age (OR=1.05, p=0.02), lower psychological distress (OR=0.43, p=0.02), and better physical functioning (OR=1.09, p=0.01). Higher use over 12 months was also associated with older age (OR=1.05, p=0.007), better physical functioning (OR=1.13, p=0.001), and greater satisfaction with technology training (OR=3.05, p=0.02). Correlates were different for short- and long-term use of mobile technology for health self-monitoring in the first year post-transplantation. It is important to follow up with LTR with longer hospital stay, poor physical functioning, and psychological distress, providing ongoing education to improve their long-term use of technology for health self-monitoring.

  2. Estimation of cross talk between lungs and liver for 241Am using phoswich detector

    International Nuclear Information System (INIS)

    Mishra, Lokpati; Nadar, Minal Y.; Singh, I.S.; Sawant, P.D.

    2018-01-01

    241 Am is used as a tracer for in-vivo assessment of plutonium (Pu) in the lungs. Internal contamination of 241 Am is estimated by measuring its 59.5 keV photons then activity of Pu is estimated by applying Pu/ 241 Am ratio obtained from radiochemical analysis of fecal/workplace sample. According to ICRP systemic bio-kinetic model, for Type M compounds of 241 Am after 100 days post inhalation intake, 241 Am activity in liver exceeds 241 Am activity present in the lungs and goes on increasing even up to about ten years. In this work, cross talk (CT) between lungs and liver viz. CT (liver to lungs) and CT (lungs to liver) for the actinide monitoring system for 241 Am using realistic thorax Lawrence Livermore National Laboratory (LLNL) phantom were estimated. Also CT has been estimated using voxel phantom by carrying out Monte Carlo simulations in FLUKA code. This study will help in reporting the actual activity present in the individual organ (lungs, liver)

  3. Lung volumes and emphysema in smokers with interstitial lung abnormalities.

    Science.gov (United States)

    Washko, George R; Hunninghake, Gary M; Fernandez, Isis E; Nishino, Mizuki; Okajima, Yuka; Yamashiro, Tsuneo; Ross, James C; Estépar, Raúl San José; Lynch, David A; Brehm, John M; Andriole, Katherine P; Diaz, Alejandro A; Khorasani, Ramin; D'Aco, Katherine; Sciurba, Frank C; Silverman, Edwin K; Hatabu, Hiroto; Rosas, Ivan O

    2011-03-10

    Cigarette smoking is associated with emphysema and radiographic interstitial lung abnormalities. The degree to which interstitial lung abnormalities are associated with reduced total lung capacity and the extent of emphysema is not known. We looked for interstitial lung abnormalities in 2416 (96%) of 2508 high-resolution computed tomographic (HRCT) scans of the lung obtained from a cohort of smokers. We used linear and logistic regression to evaluate the associations between interstitial lung abnormalities and HRCT measurements of total lung capacity and emphysema. Interstitial lung abnormalities were present in 194 (8%) of the 2416 HRCT scans evaluated. In statistical models adjusting for relevant covariates, interstitial lung abnormalities were associated with reduced total lung capacity (-0.444 liters; 95% confidence interval [CI], -0.596 to -0.292; Ppulmonary disease (COPD) (odds ratio, 0.53; 95% CI, 0.37 to 0.76; P<0.001). The effect of interstitial lung abnormalities on total lung capacity and emphysema was dependent on COPD status (P<0.02 for the interactions). Interstitial lung abnormalities were positively associated with both greater exposure to tobacco smoke and current smoking. In smokers, interstitial lung abnormalities--which were present on about 1 of every 12 HRCT scans--were associated with reduced total lung capacity and a lesser amount of emphysema. (Funded by the National Institutes of Health and the Parker B. Francis Foundation; ClinicalTrials.gov number, NCT00608764.).

  4. Analyzing the Pattern of L1 Sounds on L2 Sounds Produced by Javanese Students of Stkip PGRI Jombang

    Directory of Open Access Journals (Sweden)

    Daning Hentasmaka

    2015-07-01

    Full Text Available The studyconcerns on an analysis on the tendency of first language (L1 sound patterning on second language (L2 sounds done by Javanese students.Focusing on the consonant sounds, the data were collected by recording students’ pronunciationof English words during the pronunciation test. The data then analysed through three activities: data reduction, data display, and conclusion drawing/ verification. Theresult showedthatthe patterning of L1 sounds happened on L2 sounds especially on eleven consonant sounds: the fricatives [v, θ, ð, ʃ, ʒ], the voiceless stops [p, t, k], and the voiced stops [b, d, g].Thosepatterning case emergedmostlyduetothe difference in the existence of consonant sounds and rules of consonant distribution. Besides, one of the cases was caused by the difference in consonant clusters between L1 and L2

  5. ANALYZING THE PATTERN OF L1 SOUNDS ON L2 SOUNDS PRODUCED BY JAVANESE STUDENTS OF STKIP PGRI JOMBANG

    Directory of Open Access Journals (Sweden)

    Daning Hentasmaka

    2015-07-01

    Full Text Available The studyconcerns on an analysis on the tendency of first language (L1 sound patterning on second language (L2 sounds done by Javanese students.Focusing on the consonant sounds, the data were collected by recording students’ pronunciationof English words during the pronunciation test. The data then analysed through three activities: data reduction, data display, and conclusion drawing/ verification. Theresult showedthatthe patterning of L1 sounds happened on L2 sounds especially on eleven consonant sounds: the fricatives [v, θ, ð, ʃ, ʒ], the voiceless stops [p, t, k], and the voiced stops [b, d, g].Thosepatterning case emergedmostlyduetothe difference in the existence of consonant sounds and rules of consonant distribution. Besides, one of the cases was caused by the difference in consonant clusters between L1 and L2.

  6. Marine Animal Sound Database. Twelve Years of Tracking 52-Hz Whale Calls from a Unique Source in the North Pacific

    National Research Council Canada - National Science Library

    Watkins, William

    2004-01-01

    Long-term monitoring of underwater sounds using U.S. Navy SOSUS and other hydrophone arrays allowed us to follow the seasonal distribution of underwater calls produced by blue, fin and humpback whales across the North Pacific...

  7. Opponent Coding of Sound Location (Azimuth) in Planum Temporale is Robust to Sound-Level Variations.

    Science.gov (United States)

    Derey, Kiki; Valente, Giancarlo; de Gelder, Beatrice; Formisano, Elia

    2016-01-01

    Coding of sound location in auditory cortex (AC) is only partially understood. Recent electrophysiological research suggests that neurons in mammalian auditory cortex are characterized by broad spatial tuning and a preference for the contralateral hemifield, that is, a nonuniform sampling of sound azimuth. Additionally, spatial selectivity decreases with increasing sound intensity. To accommodate these findings, it has been proposed that sound location is encoded by the integrated activity of neuronal populations with opposite hemifield tuning ("opponent channel model"). In this study, we investigated the validity of such a model in human AC with functional magnetic resonance imaging (fMRI) and a phase-encoding paradigm employing binaural stimuli recorded individually for each participant. In all subjects, we observed preferential fMRI responses to contralateral azimuth positions. Additionally, in most AC locations, spatial tuning was broad and not level invariant. We derived an opponent channel model of the fMRI responses by subtracting the activity of contralaterally tuned regions in bilateral planum temporale. This resulted in accurate decoding of sound azimuth location, which was unaffected by changes in sound level. Our data thus support opponent channel coding as a neural mechanism for representing acoustic azimuth in human AC. © The Author 2015. Published by Oxford University Press.

  8. Lung Cancer Messages on Twitter: Content Analysis and Evaluation.

    Science.gov (United States)

    Sutton, Jeannette; Vos, Sarah C; Olson, Michele K; Woods, Chelsea; Cohen, Elisia; Gibson, C Ben; Phillips, Nolan Edward; Studts, Jamie L; Eberth, Jan M; Butts, Carter T

    2018-01-01

    The aim of this project was to describe and evaluate the levels of lung cancer communication across the cancer prevention and control continuum for content posted to Twitter during a 10-day period (September 30 to October 9) in 2016. Descriptive and inferential statistics were used to identify relationships between tweet characteristics in lung cancer communication on Twitter and user-level data. Overall, 3,000 tweets published between September 30 and October 9 were assessed by a team of three coders. Lung cancer-specific tweets by user type (individuals, media, and organizations) were examined to identify content and structural message features. The study also assessed differences by user type in the use of hashtags, directed messages, health topic focus, and lung cancer-specific focus across the cancer control continuum. Across the universe of lung cancer tweets, the majority of tweets focused on treatment and the use of pharmaceutical and research interventions, followed by awareness and prevention and risk topics. Among all lung cancer tweets, messages were most consistently tweeted by individual users, and personal behavioral mobilizing cues to action were rare. Lung cancer advocates, as well as patient and medical advocacy organizations, with an interest in expanding the reach and effectiveness of social media efforts should monitor the topical nature of public tweets across the cancer continuum and consider integrating cues to action as a strategy to increase engagement and behavioral activation pertaining to lung cancer reduction efforts. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  9. Breaking the Sound Barrier

    Science.gov (United States)

    Brown, Tom; Boehringer, Kim

    2007-01-01

    Students in a fourth-grade class participated in a series of dynamic sound learning centers followed by a dramatic capstone event--an exploration of the amazing Trashcan Whoosh Waves. It's a notoriously difficult subject to teach, but this hands-on, exploratory approach ignited student interest in sound, promoted language acquisition, and built…

  10. Sound therapies for tinnitus management.

    Science.gov (United States)

    Jastreboff, Margaret M

    2007-01-01

    Many people with bothersome (suffering) tinnitus notice that their tinnitus changes in different acoustical surroundings, it is more intrusive in silence and less profound in the sound enriched environments. This observation led to the development of treatment methods for tinnitus utilizing sound. Many of these methods are still under investigation in respect to their specific protocol and effectiveness and only some have been objectively evaluated in clinical trials. This chapter will review therapies for tinnitus using sound stimulation.

  11. Numerical Model on Sound-Solid Coupling in Human Ear and Study on Sound Pressure of Tympanic Membrane

    Directory of Open Access Journals (Sweden)

    Yao Wen-juan

    2011-01-01

    Full Text Available Establishment of three-dimensional finite-element model of the whole auditory system includes external ear, middle ear, and inner ear. The sound-solid-liquid coupling frequency response analysis of the model was carried out. The correctness of the FE model was verified by comparing the vibration modes of tympanic membrane and stapes footplate with the experimental data. According to calculation results of the model, we make use of the least squares method to fit out the distribution of sound pressure of external auditory canal and obtain the sound pressure function on the tympanic membrane which varies with frequency. Using the sound pressure function, the pressure distribution on the tympanic membrane can be directly derived from the sound pressure at the external auditory canal opening. The sound pressure function can make the boundary conditions of the middle ear structure more accurate in the mechanical research and improve the previous boundary treatment which only applied uniform pressure acting to the tympanic membrane.

  12. Sounds in one-dimensional superfluid helium

    International Nuclear Information System (INIS)

    Um, C.I.; Kahng, W.H.; Whang, E.H.; Hong, S.K.; Oh, H.G.; George, T.F.

    1989-01-01

    The temperature variations of first-, second-, and third-sound velocity and attenuation coefficients in one-dimensional superfluid helium are evaluated explicitly for very low temperatures and frequencies (ω/sub s/tau 2 , and the ratio of second sound to first sound becomes unity as the temperature decreases to absolute zero

  13. Conditioned sounds enhance visual processing.

    Directory of Open Access Journals (Sweden)

    Fabrizio Leo

    Full Text Available This psychophysics study investigated whether prior auditory conditioning influences how a sound interacts with visual perception. In the conditioning phase, subjects were presented with three pure tones ( =  conditioned stimuli, CS that were paired with positive, negative or neutral unconditioned stimuli. As unconditioned reinforcers we employed pictures (highly pleasant, unpleasant and neutral or monetary outcomes (+50 euro cents, -50 cents, 0 cents. In the subsequent visual selective attention paradigm, subjects were presented with near-threshold Gabors displayed in their left or right hemifield. Critically, the Gabors were presented in synchrony with one of the conditioned sounds. Subjects discriminated whether the Gabors were presented in their left or right hemifields. Participants determined the location more accurately when the Gabors were presented in synchrony with positive relative to neutral sounds irrespective of reinforcer type. Thus, previously rewarded relative to neutral sounds increased the bottom-up salience of the visual Gabors. Our results are the first demonstration that prior auditory conditioning is a potent mechanism to modulate the effect of sounds on visual perception.

  14. Characterizing noise in the global nuclear weapon monitoring system

    Science.gov (United States)

    Schultz, Colin

    2013-03-01

    Under the auspices of the Comprehensive Nuclear-Test-Ban Treaty Organization, a worldwide monitoring system designed to detect the illegal testing of nuclear weaponry has been under construction since 1999. The International Monitoring System is composed of a range of sensors, including detectors for hydroacoustic and seismic signals, and when completed, will include 60 infrasound measurement arrays set to detect low-frequency sound waves produced by an atmospheric nuclear detonation.

  15. Lung cancer mimicking lung abscess formation on CT images.

    Science.gov (United States)

    Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi

    2014-01-01

    Male, 64 FINAL DIAGNOSIS: Lung pleomorphic carcinoma Symptoms: Cough • fever - Clinical Procedure: - Specialty: Oncology. Unusual clinical course. The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resembled a lung abscess on CT. We herein describe the case of 64-year-old male who was diagnosed with lung cancer using surgery. In this case, it was quite difficult to distinguish between the lung cancer and a lung abscess on CT images, and a lung abscess was initially suspected due to symptoms, such as fever and coughing, contrast-enhanced CT image findings showing a ring-enhancing mass in the right upper lobe and the patient's laboratory test results. However, a pathological diagnosis of lung cancer was confirmed according to the results of a rapid frozen section biopsy of the lesion. This case suggests that physicians should not suspect both a lung abscesses and malignancy in cases involving masses presenting as ring-enhancing lesions on contrast-enhanced CT.

  16. DEVELOPING AND IMPLEMENTING AN ESTUARINE WATER QUALITY MONITORING, ASSESSMENT AND OUTREACH PROGRAM/THE MYSOUND PROJECT

    Science.gov (United States)

    EPA has developed a technology transfer handbook for the EMPACT MYSound Project. The handbook highlights information and monitoring technologies developed from the EMPACT Long Island Sound Marine Monitoring (MYSound) Project. As part of the MYSound effort, telemetering data-buoys...

  17. Transfer factor, lung volumes, resistance and ventilation distribution in healthy adults.

    Science.gov (United States)

    Verbanck, Sylvia; Van Muylem, Alain; Schuermans, Daniel; Bautmans, Ivan; Thompson, Bruce; Vincken, Walter

    2016-01-01

    Monitoring of chronic lung disease requires reference values of lung function indices, including putative markers of small airway function, spanning a wide age range.We measured spirometry, transfer factor of the lung for carbon monoxide (TLCO), static lung volume, resistance and ventilation distribution in a healthy population, studying at least 20 subjects per sex and per decade between the ages of 20 and 80 years.With respect to the Global Lung Function Initiative reference data, our subjects had average z-scores for forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC of -0.12, 0.04 and -0.32, respectively. Reference equations were obtained which could account for a potential dependence of index variability on age and height. This was done for (but not limited to) indices that are pertinent to asthma and chronic obstructive pulmonary disease studies: forced expired volume in 6 s, forced expiratory flow, TLCO, specific airway conductance, residual volume (RV)/total lung capacity (TLC), and ventilation heterogeneity in acinar and conductive lung zones.Deterioration in acinar ventilation heterogeneity and lung clearance index with age were more marked beyond 60 years, and conductive ventilation heterogeneity showed the greatest increase in variability with age. The most clinically relevant deviation from published reference values concerned RV/TLC values, which were considerably smaller than American Thoracic Society/European Respiratory Society-endorsed reference values. Copyright ©ERS 2016.

  18. Sound-Symbolism Boosts Novel Word Learning

    Science.gov (United States)

    Lockwood, Gwilym; Dingemanse, Mark; Hagoort, Peter

    2016-01-01

    The existence of sound-symbolism (or a non-arbitrary link between form and meaning) is well-attested. However, sound-symbolism has mostly been investigated with nonwords in forced choice tasks, neither of which are representative of natural language. This study uses ideophones, which are naturally occurring sound-symbolic words that depict sensory…

  19. Second sound tracking system

    Science.gov (United States)

    Yang, Jihee; Ihas, Gary G.; Ekdahl, Dan

    2017-10-01

    It is common that a physical system resonates at a particular frequency, whose frequency depends on physical parameters which may change in time. Often, one would like to automatically track this signal as the frequency changes, measuring, for example, its amplitude. In scientific research, one would also like to utilize the standard methods, such as lock-in amplifiers, to improve the signal to noise ratio. We present a complete He ii second sound system that uses positive feedback to generate a sinusoidal signal of constant amplitude via automatic gain control. This signal is used to produce temperature/entropy waves (second sound) in superfluid helium-4 (He ii). A lock-in amplifier limits the oscillation to a desirable frequency and demodulates the received sound signal. Using this tracking system, a second sound signal probed turbulent decay in He ii. We present results showing that the tracking system is more reliable than those of a conventional fixed frequency method; there is less correlation with temperature (frequency) fluctuation when the tracking system is used.

  20. Monitoring of aquifer pump tests with Magnetic Resonance Sounding (MRS): a synthetic case study

    DEFF Research Database (Denmark)

    Herckenrath, Daan; Auken, E.; Bauer-Gottwein, Peter

    2011-01-01

    Magnetic Resonance Sounding (MRS) can provide valuable data to constrain and calibrate groundwater flow and transport models. With this non-invasive geophysical technique, measurements of water content and hydraulic conductivity can be obtained. We developed a hydrogeophyiscal forward method, which...... calculates the MRS-signal generated by an aquifer pump test. A synthetic MRS-dataset was subsequently used to determine the hydrogeological parameters in an inverse parameter estimation approach. This was done for a virtual pump test with a partially and a fully penetrating well. With the MRS data we were...

  1. Underwater Sound Propagation from Marine Pile Driving.

    Science.gov (United States)

    Reyff, James A

    2016-01-01

    Pile driving occurs in a variety of nearshore environments that typically have very shallow-water depths. The propagation of pile-driving sound in water is complex, where sound is directly radiated from the pile as well as through the ground substrate. Piles driven in the ground near water bodies can produce considerable underwater sound energy. This paper presents examples of sound propagation through shallow-water environments. Some of these examples illustrate the substantial variation in sound amplitude over time that can be critical to understand when computing an acoustic-based safety zone for aquatic species.

  2. Lung allograft rejection in the rat. I. Accelerated rejection caused by graft lymphocytes

    International Nuclear Information System (INIS)

    Prop, J.; Nieuwenhuis, P.; Wildevuur, C.R.

    1985-01-01

    To find out to what extent rejection of lungs differs from that of other organs, functional rejection of lung allografts was studied in five combinations of inbred rat strains. Rejection could be monitored accurately by perfusion scintigraphy, and equally well by chest roentgenography. The rejection of lung grafts was found to proceed remarkably fast, when compared with heart grafts, in combinations with strong RT1-incompatibilities. This accelerated rejection pattern could be converted into rejection at a normal pace by pretreatment of the donor with 10 Gy roentgen irradiation one day before transplantation. Donor pretreatment depleted the lung graft's bronchus-associated lymphoid tissue (BALT) of lymphocytes. When grafts were depleted of all other passenger cells as well--by retransplantation from a cyclosporine-treated intermediate host--they showed an even more reduced immunogenicity, probably because of the loss of donor-type dendritic cells. These results indicate that lymphocytes from the BALT of lung grafts are capable of accelerating the rejection response

  3. Sound topology, duality, coherence and wave-mixing an introduction to the emerging new science of sound

    CERN Document Server

    Deymier, Pierre

    2017-01-01

    This book offers an essential introduction to the notions of sound wave topology, duality, coherence and wave-mixing, which constitute the emerging new science of sound. It includes general principles and specific examples that illuminate new non-conventional forms of sound (sound topology), unconventional quantum-like behavior of phonons (duality), radical linear and nonlinear phenomena associated with loss and its control (coherence), and exquisite effects that emerge from the interaction of sound with other physical and biological waves (wave mixing).  The book provides the reader with the foundations needed to master these complex notions through simple yet meaningful examples. General principles for unraveling and describing the topology of acoustic wave functions in the space of their Eigen values are presented. These principles are then applied to uncover intrinsic and extrinsic approaches to achieving non-conventional topologies by breaking the time revers al symmetry of acoustic waves. Symmetry brea...

  4. Diffuse sound field: challenges and misconceptions

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2016-01-01

    Diffuse sound field is a popular, yet widely misused concept. Although its definition is relatively well established, acousticians use this term for different meanings. The diffuse sound field is defined by a uniform sound pressure distribution (spatial diffusion or homogeneity) and uniform...... tremendously in different chambers because the chambers are non-diffuse in variously different ways. Therefore, good objective measures that can quantify the degree of diffusion and potentially indicate how to fix such problems in reverberation chambers are needed. Acousticians often blend the concept...... of mixing and diffuse sound field. Acousticians often refer diffuse reflections from surfaces to diffuseness in rooms, and vice versa. Subjective aspects of diffuseness have not been much investigated. Finally, ways to realize a diffuse sound field in a finite space are discussed....

  5. Lung Homeostasis: Influence of Age, Microbes, and the Immune System.

    Science.gov (United States)

    Lloyd, Clare M; Marsland, Benjamin J

    2017-04-18

    Pulmonary immune homeostasis is maintained by a network of tissue-resident cells that continually monitor the external environment, and in health, instruct tolerance to innocuous inhaled particles while ensuring that efficient and rapid immune responses can be mounted against invading pathogens. Here we review the multiple pathways that underlie effective lung immunity in health, and discuss how these may be affected by external environmental factors and contribute to chronic inflammation during disease. In this context, we examine the current understanding of the impact of the microbiota in immune development and function and in the setting of the threshold for immune responses that maintains the balance between tolerance and chronic inflammation in the lung. We propose that host interactions with microbes are critical for establishing the immune landscape of the lungs. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Remote auscultatory patient monitoring during magnetic resonance imaging

    DEFF Research Database (Denmark)

    Henneberg, S; Hök, B; Wiklund, L

    1992-01-01

    A system for patient monitoring during magnetic resonance imaging (MRI) is described. The system is based on remote auscultation of heart sounds and respiratory sounds using specially developed pickup heads that are positioned on the precordium or at the nostrils and connected to microphones via...... can be simultaneously auscultated both inside and outside the shielded MRI room by infrared transmission through a metal mesh window. Bench tests of the system show that common mode acoustic noise is suppressed by approximately 30 dB in the frequency region of interest (100-1,000 Hz), and that polymer...

  7. Radiotherapy of lung cancer: the inspiration breath hold with a spirometric monitoring

    International Nuclear Information System (INIS)

    Garcia, R.; Oozeer, R.; Le Thanh, H.; Chastel, D.; Doyen, J.C.; Chauvet, B.; Reboul, F.

    2002-01-01

    A CT acquisition during a free breathing examination generates images of poor quality. It creates an uncertainty on the reconstructed gross tumour volume and dose distribution. The aim of this study is to test the feasibility of a breath hold method applied in all preparation and treatment days. Five patients received a thoracic radiotherapy with the benefit of this procedure. The breathing of the patient was measured with a spirometer. The patient was coached to reproduce a constant level of breath-hold in a deep inspiration. Video glasses helped the patients to fix the breath-hold at the reference level. The patients followed the coaching during preparation and treatment, without any difficulty. The better quality of the CT reconstructed images resulted in an easier contouring. No movements of the gross tumour volume lead to a better coverage. The deep breath hold decreased the volume of irradiated lung. This method improves the reproducibility of the thoracic irradiation. The decrease of irradiated lung volume offers prospects in dose escalation and intensity modulation radiotherapy. (authors)

  8. International Congress on Recent Developments in Air- and Structure-Borne Sound and Vibration, 2nd, Auburn Univ., AL, Mar. 4-6, 1992, Proceedings. Vols. 1-3

    Science.gov (United States)

    Crocker, Malcolm J. (Editor); Raju, P. K. (Editor)

    1992-01-01

    The papers presented in this volume cover a variety of topics, including sound intensity, structural intensity, modal analysis and synthesis, statistical energy analysis and energy methods, passive and active damping, and boundary element methods. Attention is also given to diagnostics and condition monitoring, material characterization and nondestructive evaluation, active noise and vibration control, sound radiation and scattering, and finite element analysis.

  9. A unified approach for EIT imaging of regional overdistension and atelectasis in acute lung injury.

    Science.gov (United States)

    Gómez-Laberge, Camille; Arnold, John H; Wolf, Gerhard K

    2012-03-01

    Patients with acute lung injury or acute respiratory distress syndrome (ALI/ARDS) are vulnerable to ventilator-induced lung injury. Although this syndrome affects the lung heterogeneously, mechanical ventilation is not guided by regional indicators of potential lung injury. We used electrical impedance tomography (EIT) to estimate the extent of regional lung overdistension and atelectasis during mechanical ventilation. Techniques for tidal breath detection, lung identification, and regional compliance estimation were combined with the Graz consensus on EIT lung imaging (GREIT) algorithm. Nine ALI/ARDS patients were monitored during stepwise increases and decreases in airway pressure. Our method detected individual breaths with 96.0% sensitivity and 97.6% specificity. The duration and volume of tidal breaths erred on average by 0.2 s and 5%, respectively. Respiratory system compliance from EIT and ventilator measurements had a correlation coefficient of 0.80. Stepwise increases in pressure could reverse atelectasis in 17% of the lung. At the highest pressures, 73% of the lung became overdistended. During stepwise decreases in pressure, previously-atelectatic regions remained open at sub-baseline pressures. We recommend that the proposed approach be used in collaborative research of EIT-guided ventilation strategies for ALI/ARDS.

  10. Extreme Energy Events Monitoring report

    CERN Document Server

    Baimukhamedova, Nigina

    2015-01-01

    Following paper reflects the progress I made on Summer Student Program within Extreme Energy Events Monitor project I was working on. During 8 week period I managed to build a simple detector system that is capable of triggering events similar to explosions (sudden change in sound levels) and measuring approximate location of the event. Source codes are available upon request and settings described further.

  11. Non-invasive determination of absolute lung resistivity in adults using electrical impedance tomography

    International Nuclear Information System (INIS)

    Zhang, Jie; Patterson, Robert

    2010-01-01

    Lung resistivity is a physiological parameter that describes the electrical characteristics of the lungs. Lung composition changes due to changes in the lung tissues, fluid and air volume. Various diseases that can cause a change in lung composition may be monitored by measuring lung resistivity. Currently, there is no accepted non-invasive method to measure lung resistivity. In this study, we presented a method and framework to non-invasively determine lung resistivity using electrical impedance tomography (EIT). By comparing actual measurements from subjects with data from a 3D human thorax model, an EIT image can be reconstructed to show a resistivity difference between the model and the subject. By adjusting the lung resistivity in the model, the resistivity difference in the lung regions can be reduced to near zero. This resistivity value then is the estimation of the lung resistivity of the subject. Using the proposed method, the lung resistivities of four normal adult males (43 ± 13 years, 78 ± 10 kg) in the supine position at air volumes starting at functional residual capacity (FRC—end expiration) and increasing in 0.5 l steps to 1.5 l were studied. The averaged lung resistivity changes 12.59%, from 1406 Ω cm to 1583 Ω cm, following the inspiration of 1.5 l air from FRC. The coefficients of variation (CV) of precision for the four subjects are less than 10%. The experiment was repeated five times at each air volume on a subject to test the reproducibility. The CVs are less than 3%. The results show that it is feasible to determine absolute lung resistivity using an EIT-based method

  12. Non-invasive determination of absolute lung resistivity in adults using electrical impedance tomography.

    Science.gov (United States)

    Zhang, Jie; Patterson, Robert

    2010-08-01

    Lung resistivity is a physiological parameter that describes the electrical characteristics of the lungs. Lung composition changes due to changes in the lung tissues, fluid and air volume. Various diseases that can cause a change in lung composition may be monitored by measuring lung resistivity. Currently, there is no accepted non-invasive method to measure lung resistivity. In this study, we presented a method and framework to non-invasively determine lung resistivity using electrical impedance tomography (EIT). By comparing actual measurements from subjects with data from a 3D human thorax model, an EIT image can be reconstructed to show a resistivity difference between the model and the subject. By adjusting the lung resistivity in the model, the resistivity difference in the lung regions can be reduced to near zero. This resistivity value then is the estimation of the lung resistivity of the subject. Using the proposed method, the lung resistivities of four normal adult males (43 +/- 13 years, 78 +/- 10 kg) in the supine position at air volumes starting at functional residual capacity (FRC--end expiration) and increasing in 0.5 l steps to 1.5 l were studied. The averaged lung resistivity changes 12.59%, from 1406 Omega cm to 1583 Omega cm, following the inspiration of 1.5 l air from FRC. The coefficients of variation (CV) of precision for the four subjects are less than 10%. The experiment was repeated five times at each air volume on a subject to test the reproducibility. The CVs are less than 3%. The results show that it is feasible to determine absolute lung resistivity using an EIT-based method.

  13. Snapping shrimp sound production patterns on Caribbean coral reefs: relationships with celestial cycles and environmental variables

    Science.gov (United States)

    Lillis, Ashlee; Mooney, T. Aran

    2018-06-01

    The rich acoustic environment of coral reefs, including the sounds of a variety of fish and invertebrates, is a reflection of the structural complexity and biological diversity of these habitats. Emerging interest in applying passive acoustic monitoring and soundscape analysis to measure coral reef habitat characteristics and track ecological patterns is hindered by a poor understanding of the most common and abundant sound producers on reefs—the snapping shrimp. Here, we sought to address several basic biophysical drivers of reef sound by investigating acoustic activity patterns of snapping shrimp populations on two adjacent coral reefs using a detailed snap detection analysis routine to a high-resolution 2.5-month acoustic dataset from the US Virgin Islands. The reefs exhibited strong diel and lunar periodicity in snap rates and clear spatial differences in snapping levels. Snap rates peaked at dawn and dusk and were higher overall during daytime versus nighttime, a seldom-reported pattern in earlier descriptions of diel snapping shrimp acoustic activity. Small differences between the sites in snap rate rhythms were detected and illustrate how analyses of specific soundscape elements might reveal subtle between-reef variation. Snap rates were highly correlated with environmental variables, including water temperature and light, and were found to be sensitive to changes in oceanographic forcing. This study further establishes snapping shrimp as key players in the coral reef chorus and provides evidence that their acoustic output reflects a combination of environmental conditions, celestial influences, and spatial habitat variation. Effective application of passive acoustic monitoring in coral reef habitats using snap rates or snapping-influenced acoustic metrics will require a mechanistic understanding of the underlying spatial and temporal variation in snapping shrimp sound production across multiple scales.

  14. Social and Economic Considerations for Coastal and Watershed Restoration in the Puget Sound, Washington: A Literature Review

    Science.gov (United States)

    Stinchfield, Holly M.; Koontz, Lynne; Sexton, Natalie R.

    2009-01-01

    This literature review summarizes and synthesizes the available information regarding the impacts of socioeconomic factors on coastal and watershed restoration in the Puget Sound, Wash. Major topic areas which are explored include: institutions and restoration; beliefs, behaviors, and knowledge about restoration and the environment; stakeholder involvement in restoration, communication of restoration issues, and economic issues in restoration. The review revealed that socioeconomic factors play an important role in determining the designation, process, and success of restoration projects. Socioeconomic factors can facilitate or obstruct restoration, but few large-scale restoration projects emphasize them in either prioritization or monitoring procedures. Additionally, there are substantial gaps in the literature regarding restoration in the Puget Sound across all of the topics addressed in this review. The lack of research makes it difficult to provide a holistic view of the social and economic dimensions of restoration in the Sound but provides opportunity for future research.

  15. Monitor, a Vibrotactile Aid for Environmental Perception: A Field Evaluation by Four People with Severe Hearing and Vision Impairment

    Directory of Open Access Journals (Sweden)

    Parivash Ranjbar

    2013-01-01

    Full Text Available Monitor is a portable vibrotactile aid to improve the ability of people with severe hearing impairment or deafblindness to detect, identify, and recognize the direction of sound-producing events. It transforms and adapts sounds to the frequency sensitivity range of the skin. The aid was evaluated in the field. Four females (44–54 years with Usher Syndrome I (three with tunnel vision and one with only light perception tested the aid at home and in traffic in three different field studies: without Monitor, with Monitor with an omnidirectional microphone, and with Monitor with a directional microphone. The tests were video-documented, and the two field studies with Monitor were initiated after five weeks of training. The detection scores with omnidirectional and directional microphones were 100% for three participants and above 57% for one, both in their home and traffic environments. In the home environment the identification scores with the omnidirectional microphone were 70%–97% and 58%–95% with the directional microphone. The corresponding values in traffic were 29%–100% and 65%–100%, respectively. Their direction perception was improved to some extent by both microphones. Monitor improved the ability of people with deafblindness to detect, identify, and recognize the direction of events producing sounds.

  16. Monitor, a vibrotactile aid for environmental perception: a field evaluation by four people with severe hearing and vision impairment.

    Science.gov (United States)

    Ranjbar, Parivash; Stenström, Ingeborg

    2013-01-01

    Monitor is a portable vibrotactile aid to improve the ability of people with severe hearing impairment or deafblindness to detect, identify, and recognize the direction of sound-producing events. It transforms and adapts sounds to the frequency sensitivity range of the skin. The aid was evaluated in the field. Four females (44-54 years) with Usher Syndrome I (three with tunnel vision and one with only light perception) tested the aid at home and in traffic in three different field studies: without Monitor, with Monitor with an omnidirectional microphone, and with Monitor with a directional microphone. The tests were video-documented, and the two field studies with Monitor were initiated after five weeks of training. The detection scores with omnidirectional and directional microphones were 100% for three participants and above 57% for one, both in their home and traffic environments. In the home environment the identification scores with the omnidirectional microphone were 70%-97% and 58%-95% with the directional microphone. The corresponding values in traffic were 29%-100% and 65%-100%, respectively. Their direction perception was improved to some extent by both microphones. Monitor improved the ability of people with deafblindness to detect, identify, and recognize the direction of events producing sounds.

  17. Lung density

    DEFF Research Database (Denmark)

    Garnett, E S; Webber, C E; Coates, G

    1977-01-01

    The density of a defined volume of the human lung can be measured in vivo by a new noninvasive technique. A beam of gamma-rays is directed at the lung and, by measuring the scattered gamma-rays, lung density is calculated. The density in the lower lobe of the right lung in normal man during quiet...... breathing in the sitting position ranged from 0.25 to 0.37 g.cm-3. Subnormal values were found in patients with emphsema. In patients with pulmonary congestion and edema, lung density values ranged from 0.33 to 0.93 g.cm-3. The lung density measurement correlated well with the findings in chest radiographs...... but the lung density values were more sensitive indices. This was particularly evident in serial observations of individual patients....

  18. Deterioration in lung function following hemithorax irradiation for pleural mesothelioma

    International Nuclear Information System (INIS)

    Maasilta, P.

    1991-01-01

    Thirty-four patients receiving high-dose hemithorax irradiation as part of the treatment for pleural mesothelioma were studied with regard to changes in lung function following irradiation, and these changes were correlated with the radiologically-assessed lung injury. The latter was scored from 0 to 500 and found to be severe by 6 months (mean score 360), very severe by 9 months (mean score 430), and nearly total by 12 months (mean score 480) after treatment. Forced vital capacity and diffusing capacity both showed a significant decline at 1.5-2 months following the end of radiotherapy and thereafter up to the end of the 1 year follow-up period. Neither of these variables could be correlated consistently with the radiologically-assessed changes. Hypoxemia and pathological physiological shunting increased transiently 1-2 months after irradiation in 2 of the 6 patients monitored. The observed radiologically-assessed final effects of high-dose hemithorax irradiation are compatible with a total loss of lung function on the irradiated side. Before this form of treatment is used, lung function should be evaluated as for pneumonectomy

  19. Classification of pulmonary pathology from breath sounds using the wavelet packet transform and an extreme learning machine.

    Science.gov (United States)

    Palaniappan, Rajkumar; Sundaraj, Kenneth; Sundaraj, Sebastian; Huliraj, N; Revadi, S S

    2017-06-08

    Auscultation is a medical procedure used for the initial diagnosis and assessment of lung and heart diseases. From this perspective, we propose assessing the performance of the extreme learning machine (ELM) classifiers for the diagnosis of pulmonary pathology using breath sounds. Energy and entropy features were extracted from the breath sound using the wavelet packet transform. The statistical significance of the extracted features was evaluated by one-way analysis of variance (ANOVA). The extracted features were inputted into the ELM classifier. The maximum classification accuracies obtained for the conventional validation (CV) of the energy and entropy features were 97.36% and 98.37%, respectively, whereas the accuracies obtained for the cross validation (CRV) of the energy and entropy features were 96.80% and 97.91%, respectively. In addition, maximum classification accuracies of 98.25% and 99.25% were obtained for the CV and CRV of the ensemble features, respectively. The results indicate that the classification accuracy obtained with the ensemble features was higher than those obtained with the energy and entropy features.

  20. Reconstruction of conductivity change in lung lobes utilizing electrical impedance tomography

    Directory of Open Access Journals (Sweden)

    Schullcke Benjamin

    2017-09-01

    Full Text Available Electrical Impedance Tomography (EIT is a novel medical imaging technology which is expected to give valuable information for the treatment of mechanically ventilated patients as well as for patients with obstructive lung diseases. In lung-EIT electrodes are attached around the thorax to inject small alternating currents and to measure resulting voltages. These voltages depend on the internal conductivity distribution and thus on the amount of air in the lungs. Based on the measured voltages, image reconstruction algorithms are employed to generate tomographic images reflecting the regional ventilation of the lungs. However, the ill-posedness of the reconstruction problem leads to reconstructed images that are severely blurred compared to morphological imaging technologies, such as X-ray computed tomography or Magnetic Resonance Imaging. Thus, a correct identification of the particular ventilation in anatomically assignable units, e.g. lung-lobes, is often hindered. In this study a 3D-FEM model of a human thorax has been used to simulate electrode voltages at different lung conditions. Two electrode planes with 16 electrodes at each layer have been used and different amount of emphysema and mucus plugging was simulated with different severity in the lung lobes. Patient specific morphological information about the lung lobes is used in the image reconstruction process. It is shown that this kind of prior information leads to better reconstructions of the conductivity change in particular lung lobes than in classical image reconstruction approaches, where the anatomy of the patients’ lungs is not considered. Thus, the described approach has the potential to open new and promising applications for EIT. It might be used for diagnosis and disease monitoring for patients with obstructive lung diseases but also in other applications, e.g. during the placement of endobronchial valves in patients with severe emphysema.

  1. Thermo-active building systems and sound absorbers: Thermal comfort under real operation conditions

    DEFF Research Database (Denmark)

    Köhler, Benjamin; Rage, Nils; Chigot, Pierre

    2018-01-01

    Radiant systems are established today and have a high ecological potential in buildings while ensuring thermal comfort. Free-hanging sound absorbers are commonly used for room acoustic control, but can reduce the heat exchange when suspended under an active slab. The aim of this study...... is to evaluate the impact on thermal comfort of horizontal and vertical free-hanging porous sound absorbers placed in rooms of a building cooled by Thermo-Active Building System (TABS), under real operation conditions. A design comparing five different ceiling coverage ratios and two room types has been...... implemented during three measurement periods. A clear correlation between increase of ceiling coverage ratio and reduction of thermal comfort could not be derived systematically for each measurement period and room type, contrarily to what was expected from literature. In the first two monitoring periods...

  2. Detecting change in stochastic sound sequences.

    Directory of Open Access Journals (Sweden)

    Benjamin Skerritt-Davis

    2018-05-01

    Full Text Available Our ability to parse our acoustic environment relies on the brain's capacity to extract statistical regularities from surrounding sounds. Previous work in regularity extraction has predominantly focused on the brain's sensitivity to predictable patterns in sound sequences. However, natural sound environments are rarely completely predictable, often containing some level of randomness, yet the brain is able to effectively interpret its surroundings by extracting useful information from stochastic sounds. It has been previously shown that the brain is sensitive to the marginal lower-order statistics of sound sequences (i.e., mean and variance. In this work, we investigate the brain's sensitivity to higher-order statistics describing temporal dependencies between sound events through a series of change detection experiments, where listeners are asked to detect changes in randomness in the pitch of tone sequences. Behavioral data indicate listeners collect statistical estimates to process incoming sounds, and a perceptual model based on Bayesian inference shows a capacity in the brain to track higher-order statistics. Further analysis of individual subjects' behavior indicates an important role of perceptual constraints in listeners' ability to track these sensory statistics with high fidelity. In addition, the inference model facilitates analysis of neural electroencephalography (EEG responses, anchoring the analysis relative to the statistics of each stochastic stimulus. This reveals both a deviance response and a change-related disruption in phase of the stimulus-locked response that follow the higher-order statistics. These results shed light on the brain's ability to process stochastic sound sequences.

  3. Directional sound radiation from substation transformers

    International Nuclear Information System (INIS)

    Maybee, N.

    2009-01-01

    This paper presented the results of a study in which acoustical measurements at two substations were analyzed to investigate the directional behaviour of typical arrays having 2 or 3 transformers. Substation transformers produce a characteristic humming sound that is caused primarily by vibration of the core at twice the frequency of the power supply. The humming noise radiates predominantly from the tank enclosing the core. The main components of the sound are harmonics of 120 Hz. Sound pressure level data were obtained for various directions and distances from the arrays, ranging from 0.5 m to over 100 m. The measured sound pressure levels of the transformer tones displayed substantial positive and negative excursions from the calculated average values for many distances and directions. The results support the concept that the directional effects are associated with constructive and destructive interference of tonal sound waves emanating from different parts of the array. Significant variations in the directional sound pattern can occur in the near field of a single transformer or an array, and the extent of the near field is significantly larger than the scale of the array. Based on typical dimensions for substation sites, the distance to the far field may be much beyond the substation boundary and beyond typical setbacks to the closest dwellings. As such, the directional sound radiation produced by transformer arrays introduces additional uncertainty in the prediction of substation sound levels at dwellings within a few hundred meters of a substation site. 4 refs., 4 figs.

  4. Ventilation inhomogeneity in obstructive lung diseases measured by electrical impedance tomography: a simulation study.

    Science.gov (United States)

    Schullcke, B; Krueger-Ziolek, S; Gong, B; Jörres, R A; Mueller-Lisse, U; Moeller, K

    2017-10-10

    Electrical impedance tomography (EIT) has mostly been used in the Intensive Care Unit (ICU) to monitor ventilation distribution but is also promising for the diagnosis in spontaneously breathing patients with obstructive lung diseases. Beside tomographic images, several numerical measures have been proposed to quantitatively assess the lung state. In this study two common measures, the 'Global Inhomogeneity Index' and the 'Coefficient of Variation' were compared regarding their capability to reflect the severity of lung obstruction. A three-dimensional simulation model was used to simulate obstructed lungs, whereby images were reconstructed on a two-dimensional domain. Simulations revealed that minor obstructions are not adequately recognized in the reconstructed images and that obstruction above and below the electrode plane may result in misleading values of inhomogeneity measures. EIT measurements on several electrode planes are necessary to apply these measures in patients with obstructive lung diseases in a promising manner.

  5. On the sound absorption coefficient of porous asphalt pavements for oblique incident sound waves

    NARCIS (Netherlands)

    Bezemer-Krijnen, Marieke; Wijnant, Ysbrand H.; de Boer, Andries; Bekke, Dirk; Davy, J.; Don, Ch.; McMinn, T.; Dowsett, L.; Broner, N.; Burgess, M.

    2014-01-01

    A rolling tyre will radiate noise in all directions. However, conventional measurement techniques for the sound absorption of surfaces only give the absorption coefficient for normal incidence. In this paper, a measurement technique is described with which it is possible to perform in situ sound

  6. Neuroplasticity beyond sounds

    DEFF Research Database (Denmark)

    Reybrouck, Mark; Brattico, Elvira

    2015-01-01

    Capitalizing from neuroscience knowledge on how individuals are affected by the sound environment, we propose to adopt a cybernetic and ecological point of view on the musical aesthetic experience, which includes subprocesses, such as feature extraction and integration, early affective reactions...... and motor actions, style mastering and conceptualization, emotion and proprioception, evaluation and preference. In this perspective, the role of the listener/composer/performer is seen as that of an active "agent" coping in highly individual ways with the sounds. The findings concerning the neural...

  7. Statistics of natural binaural sounds.

    Directory of Open Access Journals (Sweden)

    Wiktor Młynarski

    Full Text Available Binaural sound localization is usually considered a discrimination task, where interaural phase (IPD and level (ILD disparities at narrowly tuned frequency channels are utilized to identify a position of a sound source. In natural conditions however, binaural circuits are exposed to a stimulation by sound waves originating from multiple, often moving and overlapping sources. Therefore statistics of binaural cues depend on acoustic properties and the spatial configuration of the environment. Distribution of cues encountered naturally and their dependence on physical properties of an auditory scene have not been studied before. In the present work we analyzed statistics of naturally encountered binaural sounds. We performed binaural recordings of three auditory scenes with varying spatial configuration and analyzed empirical cue distributions from each scene. We have found that certain properties such as the spread of IPD distributions as well as an overall shape of ILD distributions do not vary strongly between different auditory scenes. Moreover, we found that ILD distributions vary much weaker across frequency channels and IPDs often attain much higher values, than can be predicted from head filtering properties. In order to understand the complexity of the binaural hearing task in the natural environment, sound waveforms were analyzed by performing Independent Component Analysis (ICA. Properties of learned basis functions indicate that in natural conditions soundwaves in each ear are predominantly generated by independent sources. This implies that the real-world sound localization must rely on mechanisms more complex than a mere cue extraction.

  8. Statistics of natural binaural sounds.

    Science.gov (United States)

    Młynarski, Wiktor; Jost, Jürgen

    2014-01-01

    Binaural sound localization is usually considered a discrimination task, where interaural phase (IPD) and level (ILD) disparities at narrowly tuned frequency channels are utilized to identify a position of a sound source. In natural conditions however, binaural circuits are exposed to a stimulation by sound waves originating from multiple, often moving and overlapping sources. Therefore statistics of binaural cues depend on acoustic properties and the spatial configuration of the environment. Distribution of cues encountered naturally and their dependence on physical properties of an auditory scene have not been studied before. In the present work we analyzed statistics of naturally encountered binaural sounds. We performed binaural recordings of three auditory scenes with varying spatial configuration and analyzed empirical cue distributions from each scene. We have found that certain properties such as the spread of IPD distributions as well as an overall shape of ILD distributions do not vary strongly between different auditory scenes. Moreover, we found that ILD distributions vary much weaker across frequency channels and IPDs often attain much higher values, than can be predicted from head filtering properties. In order to understand the complexity of the binaural hearing task in the natural environment, sound waveforms were analyzed by performing Independent Component Analysis (ICA). Properties of learned basis functions indicate that in natural conditions soundwaves in each ear are predominantly generated by independent sources. This implies that the real-world sound localization must rely on mechanisms more complex than a mere cue extraction.

  9. Moth hearing and sound communication

    DEFF Research Database (Denmark)

    Nakano, Ryo; Takanashi, Takuma; Surlykke, Annemarie

    2015-01-01

    Active echolocation enables bats to orient and hunt the night sky for insects. As a counter-measure against the severe predation pressure many nocturnal insects have evolved ears sensitive to ultrasonic bat calls. In moths bat-detection was the principal purpose of hearing, as evidenced by compar......Active echolocation enables bats to orient and hunt the night sky for insects. As a counter-measure against the severe predation pressure many nocturnal insects have evolved ears sensitive to ultrasonic bat calls. In moths bat-detection was the principal purpose of hearing, as evidenced...... by comparable hearing physiology with best sensitivity in the bat echolocation range, 20–60 kHz, across moths in spite of diverse ear morphology. Some eared moths subsequently developed sound-producing organs to warn/startle/jam attacking bats and/or to communicate intraspecifically with sound. Not only...... the sounds for interaction with bats, but also mating signals are within the frequency range where bats echolocate, indicating that sound communication developed after hearing by “sensory exploitation”. Recent findings on moth sound communication reveal that close-range (~ a few cm) communication with low...

  10. Lung Cancer Screening

    Science.gov (United States)

    ... factors increase or decrease the risk of lung cancer. Lung cancer is a disease in which malignant (cancer) ... following PDQ summaries for more information about lung cancer: Lung Cancer Prevention Non-Small Cell Lung Cancer Treatment ...

  11. Lung Volume Reduction in Pulmonary Emphysema from the Radiologist's Perspective.

    Science.gov (United States)

    Doellinger, F; Huebner, R H; Kuhnigk, J M; Poellinger, A

    2015-08-01

    Pulmonary emphysema causes decrease in lung function due to irreversible dilatation of intrapulmonary air spaces, which is linked to high morbidity and mortality. Lung volume reduction (LVR) is an invasive therapeutical option for pulmonary emphysema in order to improve ventilation mechanics. LVR can be carried out by lung resection surgery or different minimally invasive endoscopical procedures. All LVR-options require mandatory preinterventional evaluation to detect hyperinflated dysfunctional lung areas as target structures for treatment. Quantitative computed tomography can determine the volume percentage of emphysematous lung and its topographical distribution based on the lung's radiodensity. Modern techniques allow for lobebased quantification that facilitates treatment planning. Clinical tests still play the most important role in post-interventional therapy monitoring, but CT is crucial in the detection of postoperative complications and foreshadows the method's high potential in sophisticated experimental studies. Within the last ten years, LVR with endobronchial valves has become an extensively researched minimally-invasive treatment option. However, this therapy is considerably complicated by the frequent occurrence of functional interlobar shunts. The presence of "collateral ventilation" has to be ruled out prior to valve implantations, as the presence of these extraanatomical connections between different lobes may jeopardize the success of therapy. Recent experimental studies evaluated the automatic detection of incomplete lobar fissures from CT scans, because they are considered to be a predictor for the existence of shunts. To date, these methods are yet to show acceptable results. Today, surgical and various minimal invasive methods of lung volume reduction are in use. Radiological and nuclear medical examinations are helpful in the evaluation of an appropriate lung area. Imaging can detect periinterventional complications. Reduction of lung

  12. Antihistamine medication may alleviate negative effects of prenatal exposure to polycyclic aromatic hydrocarbons (PAH) on lung function in children. Birth cohort prospective study.

    Science.gov (United States)

    Jedrychowski, Wieslaw A; Perera, Frederica P; Maugeri, Umberto; Majewska, Renata; Spengler, Jack; Mroz, Elzbieta; Flak, Elzbieta; Klimaszewska-Rembiasz, Maria; Camman, David

    2015-05-01

    The main purpose of the present study was to test the hypothesis that the depressed lung growth attributable to prenatal exposure to polycyclic aromatic hydrocarbons (PAH) may be modified by the intake of antihistamine medications. Individual prenatal PAH exposure was assessed by personal air monitoring in 176 children who were followed over nine years, in the course of which outdoor residential air monitoring, allergic skin tests for indoor allergens, lung function tests (FVC, FEV(1), FEV(05), and FEF(25-75)) were performed. The analysis with the General Estimated Equation (GEE) showed no association between prenatal PAH exposure and lung function in the group of children who were reported to be antihistamine users. However, in the group of antihistamine non-users all lung function tests except for FEF(25-75) were significantly and inversely associated with prenatal airborne PAH exposure. The results of the study suggest that the intake of antihistamine medications in early childhood may inhibit the negative effect of fetal PAH exposure on lung growth and provides additional indirect evidence for the hypothesis that lung alterations in young children resulting from PAH exposure may be caused by the allergic inflammation within lung. © 2014 Wiley Periodicals, Inc.

  13. Lung Cancer Mortality among Uranium Gaseous Diffusion Plant Workers: A Cohort Study 1952–2004

    Directory of Open Access Journals (Sweden)

    LW Figgs

    2013-07-01

    Full Text Available Background: 9%–15% of all lung cancers are attributable to occupational exposures. Reports are disparate regarding elevated lung cancer mortality risk among workers employed at uranium gaseous diffusion plants. Objective: To investigate whether external radiation exposure is associated with lung cancer mortality risk among uranium gaseous diffusion workers. Methods: A cohort of 6820 nuclear industry workers employed from 1952 to 2003 at the Paducah uranium gaseous diffusion plant (PGDP was assembled. A job-specific exposure matrix (JEM was used to determine likely toxic metal exposure categories. In addition, radiation film badge dosimeters were used to monitor cumulative external ionizing radiation exposure. International Classification for Disease (ICD codes 9 and 10 were used to identify 147 lung cancer deaths. Logistic and proportional hazards regression were used to estimate lung cancer mortality risk. Results: Lung cancer mortality risk was elevated among workers who experienced external radiation >3.5 mrem and employment duration >12 years. Conclusion: Employees of uranium gaseous diffusion plants carry a higher risk of lung cancer mortality; the mortality is associated with increased radiation exposure and duration of employment.

  14. Simulation of sound waves using the Lattice Boltzmann Method for fluid flow: Benchmark cases for outdoor sound propagation

    NARCIS (Netherlands)

    Salomons, E.M.; Lohman, W.J.A.; Zhou, H.

    2016-01-01

    Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases:

  15. Beacons of Sound

    DEFF Research Database (Denmark)

    Knakkergaard, Martin

    2018-01-01

    The chapter discusses expectations and imaginations vis-à-vis the concert hall of the twenty-first century. It outlines some of the central historical implications of western culture’s haven for sounding music. Based on the author’s study of the Icelandic concert-house Harpa, the chapter considers...... how these implications, together with the prime mover’s visions, have been transformed as private investors and politicians took over. The chapter furthermore investigates the objectives regarding musical sound and the far-reaching demands concerning acoustics that modern concert halls are required...

  16. Sound & The Senses

    DEFF Research Database (Denmark)

    Schulze, Holger

    2012-01-01

    How are those sounds you hear right now technically generated and post-produced, how are they aesthetically conceptualized and how culturally dependant are they really? How is your ability to hear intertwined with all the other senses and their cultural, biographical and technological constructio...... over time? And how is listening and sounding a deeply social activity – constructing our way of living together in cities as well as in apartment houses? A radio feature with Jonathan Sterne, AGF a.k.a Antye Greie, Jens Gerrit Papenburg & Holger Schulze....

  17. Nutrition for Lung Cancer

    Science.gov (United States)

    ... Become An Advocate Volunteer Ways To Give Lung Cancer www.lung.org > Lung Health and Diseases > Lung Disease Lookup > ... Cancer Learn About Lung Cancer What Is Lung Cancer Lung Cancer Basics Causes & Risk Factors Lung Cancer Staging ...

  18. Lung sound analysis can be an index of the control of bronchial asthma

    Directory of Open Access Journals (Sweden)

    Terufumi Shimoda

    2017-01-01

    Conclusions: The E/I LF measurement obtained by LSA is useful as an indicator of changes in airway obstruction and inflammation and can be used for monitoring the therapeutic course of bronchial asthma patients.

  19. Deterministic Approach to Detect Heart Sound Irregularities

    Directory of Open Access Journals (Sweden)

    Richard Mengko

    2017-07-01

    Full Text Available A new method to detect heart sound that does not require machine learning is proposed. The heart sound is a time series event which is generated by the heart mechanical system. From the analysis of heart sound S-transform and the understanding of how heart works, it can be deducted that each heart sound component has unique properties in terms of timing, frequency, and amplitude. Based on these facts, a deterministic method can be designed to identify each heart sound components. The recorded heart sound then can be printed with each component correctly labeled. This greatly help the physician to diagnose the heart problem. The result shows that most known heart sounds were successfully detected. There are some murmur cases where the detection failed. This can be improved by adding more heuristics including setting some initial parameters such as noise threshold accurately, taking into account the recording equipment and also the environmental condition. It is expected that this method can be integrated into an electronic stethoscope biomedical system.

  20. Sound For Animation And Virtual Reality

    Science.gov (United States)

    Hahn, James K.; Docter, Pete; Foster, Scott H.; Mangini, Mark; Myers, Tom; Wenzel, Elizabeth M.; Null, Cynthia (Technical Monitor)

    1995-01-01

    Sound is an integral part of the experience in computer animation and virtual reality. In this course, we will present some of the important technical issues in sound modeling, rendering, and synchronization as well as the "art" and business of sound that are being applied in animations, feature films, and virtual reality. The central theme is to bring leading researchers and practitioners from various disciplines to share their experiences in this interdisciplinary field. The course will give the participants an understanding of the problems and techniques involved in producing and synchronizing sounds, sound effects, dialogue, and music. The problem spans a number of domains including computer animation and virtual reality. Since sound has been an integral part of animations and films much longer than for computer-related domains, we have much to learn from traditional animation and film production. By bringing leading researchers and practitioners from a wide variety of disciplines, the course seeks to give the audience a rich mixture of experiences. It is expected that the audience will be able to apply what they have learned from this course in their research or production.