WorldWideScience

Sample records for lung sound analysis

  1. Portable system for auscultation and lung sound analysis.

    Science.gov (United States)

    Nabiev, Rustam; Glazova, Anna; Olyinik, Valery; Makarenkova, Anastasiia; Makarenkov, Anatolii; Rakhimov, Abdulvosid; Felländer-Tsai, Li

    2014-01-01

    A portable system for auscultation and lung sound analysis has been developed, including the original electronic stethoscope coupled with mobile devices and special algorithms for the automated analysis of pulmonary sound signals. It's planned that the developed system will be used for monitoring of health status of patients with various pulmonary diseases.

  2. Analysis of adventitious lung sounds originating from pulmonary tuberculosis.

    Science.gov (United States)

    Becker, K W; Scheffer, C; Blanckenberg, M M; Diacon, A H

    2013-01-01

    Tuberculosis is a common and potentially deadly infectious disease, usually affecting the respiratory system and causing the sound properties of symptomatic infected lungs to differ from non-infected lungs. Auscultation is often ruled out as a reliable diagnostic technique for TB due to the random distribution of the infection and the varying severity of damage to the lungs. However, advancements in signal processing techniques for respiratory sounds can improve the potential of auscultation far beyond the capabilities of the conventional mechanical stethoscope. Though computer-based signal analysis of respiratory sounds has produced a significant body of research, there have not been any recent investigations into the computer-aided analysis of lung sounds associated with pulmonary Tuberculosis (TB), despite the severity of the disease in many countries. In this paper, respiratory sounds were recorded from 14 locations around the posterior and anterior chest walls of healthy volunteers and patients infected with pulmonary TB. The most significant signal features in both the time and frequency domains associated with the presence of TB, were identified by using the statistical overlap factor (SOF). These features were then employed to train a neural network to automatically classify the auscultation recordings into their respective healthy or TB-origin categories. The neural network yielded a diagnostic accuracy of 73%, but it is believed that automated filtering of the noise in the clinics, more training samples and perhaps other signal processing methods can improve the results of future studies. This work demonstrates the potential of computer-aided auscultation as an aid for the diagnosis and treatment of TB.

  3. Lung and Heart Sounds Analysis: State-of-the-Art and Future Trends.

    Science.gov (United States)

    Padilla-Ortiz, Ana L; Ibarra, David

    2018-01-01

    Lung sounds, which include all sounds that are produced during the mechanism of respiration, may be classified into normal breath sounds and adventitious sounds. Normal breath sounds occur when no respiratory problems exist, whereas adventitious lung sounds (wheeze, rhonchi, crackle, etc.) are usually associated with certain pulmonary pathologies. Heart and lung sounds that are heard using a stethoscope are the result of mechanical interactions that indicate operation of cardiac and respiratory systems, respectively. In this article, we review the research conducted during the last six years on lung and heart sounds, instrumentation and data sources (sensors and databases), technological advances, and perspectives in processing and data analysis. Our review suggests that chronic obstructive pulmonary disease (COPD) and asthma are the most common respiratory diseases reported on in the literature; related diseases that are less analyzed include chronic bronchitis, idiopathic pulmonary fibrosis, congestive heart failure, and parenchymal pathology. Some new findings regarding the methodologies associated with advances in the electronic stethoscope have been presented for the auscultatory heart sound signaling process, including analysis and clarification of resulting sounds to create a diagnosis based on a quantifiable medical assessment. The availability of automatic interpretation of high precision of heart and lung sounds opens interesting possibilities for cardiovascular diagnosis as well as potential for intelligent diagnosis of heart and lung diseases.

  4. Application of semi-supervised deep learning to lung sound analysis.

    Science.gov (United States)

    Chamberlain, Daniel; Kodgule, Rahul; Ganelin, Daniela; Miglani, Vivek; Fletcher, Richard Ribon

    2016-08-01

    The analysis of lung sounds, collected through auscultation, is a fundamental component of pulmonary disease diagnostics for primary care and general patient monitoring for telemedicine. Despite advances in computation and algorithms, the goal of automated lung sound identification and classification has remained elusive. Over the past 40 years, published work in this field has demonstrated only limited success in identifying lung sounds, with most published studies using only a small numbers of patients (typically Ndeep learning algorithm for automatically classify lung sounds from a relatively large number of patients (N=284). Focusing on the two most common lung sounds, wheeze and crackle, we present results from 11,627 sound files recorded from 11 different auscultation locations on these 284 patients with pulmonary disease. 890 of these sound files were labeled to evaluate the model, which is significantly larger than previously published studies. Data was collected with a custom mobile phone application and a low-cost (US$30) electronic stethoscope. On this data set, our algorithm achieves ROC curves with AUCs of 0.86 for wheeze and 0.74 for crackle. Most importantly, this study demonstrates how semi-supervised deep learning can be used with larger data sets without requiring extensive labeling of data.

  5. Lung sound analysis helps localize airway inflammation in patients with bronchial asthma

    Directory of Open Access Journals (Sweden)

    Shimoda T

    2017-03-01

    Full Text Available Terufumi Shimoda,1 Yasushi Obase,2 Yukio Nagasaka,3 Hiroshi Nakano,1 Akiko Ishimatsu,1 Reiko Kishikawa,1 Tomoaki Iwanaga1 1Clinical Research Center, Fukuoka National Hospital, Fukuoka, 2Second Department of Internal Medicine, School of Medicine, Nagasaki University, Nagasaki, 3Kyoto Respiratory Center, Otowa Hospital, Kyoto, Japan Purpose: Airway inflammation can be detected by lung sound analysis (LSA at a single point in the posterior lower lung field. We performed LSA at 7 points to examine whether the technique could identify the location of airway inflammation in patients with asthma. Patients and methods: Breath sounds were recorded at 7 points on the body surface of 22 asthmatic subjects. Inspiration sound pressure level (ISPL, expiration sound pressure level (ESPL, and the expiration-to-inspiration sound pressure ratio (E/I were calculated in 6 frequency bands. The data were analyzed for potential correlation with spirometry, airway hyperresponsiveness (PC20, and fractional exhaled nitric oxide (FeNO. Results: The E/I data in the frequency range of 100–400 Hz (E/I low frequency [LF], E/I mid frequency [MF] were better correlated with the spirometry, PC20, and FeNO values than were the ISPL or ESPL data. The left anterior chest and left posterior lower recording positions were associated with the best correlations (forced expiratory volume in 1 second/forced vital capacity: r=–0.55 and r=–0.58; logPC20: r=–0.46 and r=–0.45; and FeNO: r=0.42 and r=0.46, respectively. The majority of asthmatic subjects with FeNO ≥70 ppb exhibited high E/I MF levels in all lung fields (excluding the trachea and V50%pred <80%, suggesting inflammation throughout the airway. Asthmatic subjects with FeNO <70 ppb showed high or low E/I MF levels depending on the recording position, indicating uneven airway inflammation. Conclusion: E/I LF and E/I MF are more useful LSA parameters for evaluating airway inflammation in bronchial asthma; 7-point lung

  6. Internal-state analysis in layered artificial neural network trained to categorize lung sounds

    NARCIS (Netherlands)

    Oud, M

    2002-01-01

    In regular use of artificial neural networks, only input and output states of the network are known to the user. Weight and bias values can be extracted but are difficult to interpret. We analyzed internal states of networks trained to map asthmatic lung sound spectra onto lung function parameters.

  7. Lung function interpolation by analysis of means of neural-network-supported respiration sounds

    NARCIS (Netherlands)

    Oud, M

    Respiration sounds of individual asthmatic patients were analysed in the scope of the development of a method for computerised recognition of the degree of airways obstruction. Respiration sounds were recorded during laboratory sessions of allergen provoked airways obstruction, during several stages

  8. Towards the standardisation of lung sound nomenclature

    NARCIS (Netherlands)

    Pasterkamp, Hans; Brand, Paul L. P.; Everard, Mark; Garcia-Marcos, Luis; Melbye, Hasse; Priftis, Kostas N.

    Auscultation of the lung remains an essential part of physical examination even though its limitations, particularly with regard to communicating subjective findings, are well recognised. The European Respiratory Society (ERS) Task Force on Respiratory Sounds was established to build a reference

  9. Waveform analysis of sound

    CERN Document Server

    Tohyama, Mikio

    2015-01-01

    What is this sound? What does that sound indicate? These are two questions frequently heard in daily conversation. Sound results from the vibrations of elastic media and in daily life provides informative signals of events happening in the surrounding environment. In interpreting auditory sensations, the human ear seems particularly good at extracting the signal signatures from sound waves. Although exploring auditory processing schemes may be beyond our capabilities, source signature analysis is a very attractive area in which signal-processing schemes can be developed using mathematical expressions. This book is inspired by such processing schemes and is oriented to signature analysis of waveforms. Most of the examples in the book are taken from data of sound and vibrations; however, the methods and theories are mostly formulated using mathematical expressions rather than by acoustical interpretation. This book might therefore be attractive and informative for scientists, engineers, researchers, and graduat...

  10. Reduction of heart sound interference from lung sound signals using empirical mode decomposition technique.

    Science.gov (United States)

    Mondal, Ashok; Bhattacharya, P S; Saha, Goutam

    2011-01-01

    During the recording time of lung sound (LS) signals from the chest wall of a subject, there is always heart sound (HS) signal interfering with it. This obscures the features of lung sound signals and creates confusion on pathological states, if any, of the lungs. A novel method based on empirical mode decomposition (EMD) technique is proposed in this paper for reducing the undesired heart sound interference from the desired lung sound signals. In this, the mixed signal is split into several components. Some of these components contain larger proportions of interfering signals like heart sound, environmental noise etc. and are filtered out. Experiments have been conducted on simulated and real-time recorded mixed signals of heart sound and lung sound. The proposed method is found to be superior in terms of time domain, frequency domain, and time-frequency domain representations and also in listening test performed by pulmonologist.

  11. Effects of lung elasticity on the sound propagation in the lung

    International Nuclear Information System (INIS)

    Yoneda, Takahiro; Wada, Shigeo; Nakamura, Masanori; Horii, Noriaki; Mizushima, Koichiro

    2011-01-01

    Sound propagation in the lung was simulated for gaining insight into its acoustic properties. A thorax model consisting of lung parenchyma, thoracic bones, trachea and other tissues was made from human CT images. Acoustic nature of the lung parenchyma and bones was expressed with the Biot model of poroelastic material, whereas trachea and tissues were modeled with gas and an elastic material. A point sound source of white noises was placed in the first bifurcation of trachea. The sound propagation in the thorax model was simulated in a frequency domain. The results demonstrated the significant attenuation of sound especially in frequencies larger than 1,000 Hz. Simulations with a stiffened lung demonstrated suppression of the sound attenuation for higher frequencies observed in the normal lung. These results indicate that the normal lung has the nature of a low-pass filter, and stiffening helps the sound at higher frequencies to propagate without attenuations. (author)

  12. Developing a reference of normal lung sounds in healthy Peruvian children.

    Science.gov (United States)

    Ellington, Laura E; Emmanouilidou, Dimitra; Elhilali, Mounya; Gilman, Robert H; Tielsch, James M; Chavez, Miguel A; Marin-Concha, Julio; Figueroa, Dante; West, James; Checkley, William

    2014-10-01

    Lung auscultation has long been a standard of care for the diagnosis of respiratory diseases. Recent advances in electronic auscultation and signal processing have yet to find clinical acceptance; however, computerized lung sound analysis may be ideal for pediatric populations in settings, where skilled healthcare providers are commonly unavailable. We described features of normal lung sounds in young children using a novel signal processing approach to lay a foundation for identifying pathologic respiratory sounds. 186 healthy children with normal pulmonary exams and without respiratory complaints were enrolled at a tertiary care hospital in Lima, Peru. Lung sounds were recorded at eight thoracic sites using a digital stethoscope. 151 (81%) of the recordings were eligible for further analysis. Heavy-crying segments were automatically rejected and features extracted from spectral and temporal signal representations contributed to profiling of lung sounds. Mean age, height, and weight among study participants were 2.2 years (SD 1.4), 84.7 cm (SD 13.2), and 12.0 kg (SD 3.6), respectively; and, 47% were boys. We identified ten distinct spectral and spectro-temporal signal parameters and most demonstrated linear relationships with age, height, and weight, while no differences with genders were noted. Older children had a faster decaying spectrum than younger ones. Features like spectral peak width, lower-frequency Mel-frequency cepstral coefficients, and spectro-temporal modulations also showed variations with recording site. Lung sound extracted features varied significantly with child characteristics and lung site. A comparison with adult studies revealed differences in the extracted features for children. While sound-reduction techniques will improve analysis, we offer a novel, reproducible tool for sound analysis in real-world environments.

  13. Developing a Reference of Normal Lung Sounds in Healthy Peruvian Children

    Science.gov (United States)

    Ellington, Laura E.; Emmanouilidou, Dimitra; Elhilali, Mounya; Gilman, Robert H.; Tielsch, James M.; Chavez, Miguel A.; Marin-Concha, Julio; Figueroa, Dante; West, James

    2018-01-01

    Purpose Lung auscultation has long been a standard of care for the diagnosis of respiratory diseases. Recent advances in electronic auscultation and signal processing have yet to find clinical acceptance; however, computerized lung sound analysis may be ideal for pediatric populations in settings, where skilled healthcare providers are commonly unavailable. We described features of normal lung sounds in young children using a novel signal processing approach to lay a foundation for identifying pathologic respiratory sounds. Methods 186 healthy children with normal pulmonary exams and without respiratory complaints were enrolled at a tertiary care hospital in Lima, Peru. Lung sounds were recorded at eight thoracic sites using a digital stethoscope. 151 (81 %) of the recordings were eligible for further analysis. Heavy-crying segments were automatically rejected and features extracted from spectral and temporal signal representations contributed to profiling of lung sounds. Results Mean age, height, and weight among study participants were 2.2 years (SD 1.4), 84.7 cm (SD 13.2), and 12.0 kg (SD 3.6), respectively; and, 47 % were boys. We identified ten distinct spectral and spectro-temporal signal parameters and most demonstrated linear relationships with age, height, and weight, while no differences with genders were noted. Older children had a faster decaying spectrum than younger ones. Features like spectral peak width, lower-frequency Mel-frequency cepstral coefficients, and spectro-temporal modulations also showed variations with recording site. Conclusions Lung sound extracted features varied significantly with child characteristics and lung site. A comparison with adult studies revealed differences in the extracted features for children. While sound-reduction techniques will improve analysis, we offer a novel, reproducible tool for sound analysis in real-world environments. PMID:24943262

  14. Measurement and classification of heart and lung sounds by using LabView for educational use.

    Science.gov (United States)

    Altrabsheh, B

    2010-01-01

    This study presents the design, development and implementation of a simple low-cost method of phonocardiography signal detection. Human heart and lung signals are detected by using a simple microphone through a personal computer; the signals are recorded and analysed using LabView software. Amplitude and frequency analyses are carried out for various phonocardiography pathological cases. Methods for automatic classification of normal and abnormal heart sounds, murmurs and lung sounds are presented. Various cases of heart and lung sound measurement are recorded and analysed. The measurements can be saved for further analysis. The method in this study can be used by doctors as a detection tool aid and may be useful for teaching purposes at medical and nursing schools.

  15. Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows

    NARCIS (Netherlands)

    Schreur, H. J.; Sterk, P. J.; Vanderschoot, J.; van Klink, H. C.; van Vollenhoven, E.; Dijkman, J. H.

    1992-01-01

    A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in

  16. Application of Clustering Techniques for Lung Sounds to Improve Interpretability and Detection of Crackles

    Directory of Open Access Journals (Sweden)

    Germán D. Sosa

    2015-01-01

    Full Text Available Due to the subjectivity involved currently in pulmonary auscultation process and its diagnostic to evaluate the condition of respiratory airways, this work pretends to evaluate the performance of clustering algorithms such as k-means and DBSCAN to perform a computational analysis of lung sounds aiming to visualize a representation of such sounds that highlights the presence of crackles and the energy associated with them. In order to achieve that goal, Wavelet analysis techniques were used in contrast to traditional frequency analysis given the similarity between the typical waveform for a crackle and the wavelet sym4. Once the lung sound signal with isolated crackles is obtained, the clustering process groups crackles in regions of high density and provides visualization that might be useful for the diagnostic made by an expert. Evaluation suggests that k-means groups crackle more effective than DBSCAN in terms of generated clusters.

  17. Analysis of environmental sounds

    Science.gov (United States)

    Lee, Keansub

    Environmental sound archives - casual recordings of people's daily life - are easily collected by MPS players or camcorders with low cost and high reliability, and shared in the web-sites. There are two kinds of user generated recordings we would like to be able to handle in this thesis: Continuous long-duration personal audio and Soundtracks of short consumer video clips. These environmental recordings contain a lot of useful information (semantic concepts) related with activity, location, occasion and content. As a consequence, the environment archives present many new opportunities for the automatic extraction of information that can be used in intelligent browsing systems. This thesis proposes systems for detecting these interesting concepts on a collection of these real-world recordings. The first system is to segment and label personal audio archives - continuous recordings of an individual's everyday experiences - into 'episodes' (relatively consistent acoustic situations lasting a few minutes or more) using the Bayesian Information Criterion and spectral clustering. The second system is for identifying regions of speech or music in the kinds of energetic and highly-variable noise present in this real-world sound. Motivated by psychoacoustic evidence that pitch is crucial in the perception and organization of sound, we develop a noise-robust pitch detection algorithm to locate speech or music-like regions. To avoid false alarms resulting from background noise with strong periodic components (such as air-conditioning), a new scheme is added in order to suppress these noises in the domain of autocorrelogram. In addition, the third system is to automatically detect a large set of interesting semantic concepts; which we chose for being both informative and useful to users, as well as being technically feasible. These 25 concepts are associated with people's activities, locations, occasions, objects, scenes and sounds, and are based on a large collection of

  18. Left–Right Asymmetry in Spectral Characteristics of Lung Sounds Detected Using a Dual-Channel Auscultation System in Healthy Young Adults

    Science.gov (United States)

    Tsai, Jang-Zern; Chang, Ming-Lang; Yang, Jiun-Yue; Kuo, Dar; Lin, Ching-Hsiung; Kuo, Cheng-Deng

    2017-01-01

    observed differences in the spectral characteristics of lung sounds. The dual-channel auscultation system might be useful for future development of digital stethoscopes and power spectral analysis of lung sounds in patients with various kinds of cardiopulmonary diseases. PMID:28590447

  19. Left–Right Asymmetry in Spectral Characteristics of Lung Sounds Detected Using a Dual-Channel Auscultation System in Healthy Young Adults

    Directory of Open Access Journals (Sweden)

    Jang-Zern Tsai

    2017-06-01

    account for the observed differences in the spectral characteristics of lung sounds. The dual-channel auscultation system might be useful for future development of digital stethoscopes and power spectral analysis of lung sounds in patients with various kinds of cardiopulmonary diseases.

  20. Left-Right Asymmetry in Spectral Characteristics of Lung Sounds Detected Using a Dual-Channel Auscultation System in Healthy Young Adults.

    Science.gov (United States)

    Tsai, Jang-Zern; Chang, Ming-Lang; Yang, Jiun-Yue; Kuo, Dar; Lin, Ching-Hsiung; Kuo, Cheng-Deng

    2017-06-07

    account for the observed differences in the spectral characteristics of lung sounds. The dual-channel auscultation system might be useful for future development of digital stethoscopes and power spectral analysis of lung sounds in patients with various kinds of cardiopulmonary diseases.

  1. Acoustic analysis of trill sounds.

    Science.gov (United States)

    Dhananjaya, N; Yegnanarayana, B; Bhaskararao, Peri

    2012-04-01

    In this paper, the acoustic-phonetic characteristics of steady apical trills--trill sounds produced by the periodic vibration of the apex of the tongue--are studied. Signal processing methods, namely, zero-frequency filtering and zero-time liftering of speech signals, are used to analyze the excitation source and the resonance characteristics of the vocal tract system, respectively. Although it is natural to expect the effect of trilling on the resonances of the vocal tract system, it is interesting to note that trilling influences the glottal source of excitation as well. The excitation characteristics derived using zero-frequency filtering of speech signals are glottal epochs, strength of impulses at the glottal epochs, and instantaneous fundamental frequency of the glottal vibration. Analysis based on zero-time liftering of speech signals is used to study the dynamic resonance characteristics of vocal tract system during the production of trill sounds. Qualitative analysis of trill sounds in different vowel contexts, and the acoustic cues that may help spotting trills in continuous speech are discussed.

  2. Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows.

    Science.gov (United States)

    Schreur, H J; Sterk, P J; Vanderschoot, J; van Klink, H C; van Vollenhoven, E; Dijkman, J H

    1992-01-01

    BACKGROUND: A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in normal and emphysematous subjects in relation to airflow. METHODS: Eight normal men (45-63 years, FEV1 79-126% predicted) and nine men with severe emphysema (50-70 years, FEV1 14-63% predicted) participated in the study. Emphysema was diagnosed according to pulmonary history, results of lung function tests, and radiographic criteria. All subjects underwent phonopneumography during standardised breathing manoeuvres between 0.5 and 2 1 below total lung capacity with inspiratory and expiratory target airflows of 2 and 1 l/s respectively during 50 seconds. The synchronous measurements included airflow at the mouth and lung volume changes, and lung sounds at four locations on the right chest wall. For each microphone airflow dependent power spectra were computed by using fast Fourier transformation. Lung sound intensity was expressed as log power (in dB) at 200 Hz at inspiratory flow rates of 1 and 2 l/s and at an expiratory flow rate of 1 l/s. RESULTS: Lung sound intensity was well repeatable on two separate days, the intraclass correlation coefficient ranging from 0.77 to 0.94 between the four microphones. The intensity was strongly influenced by microphone location and airflow. There was, however, no significant difference in lung sound intensity at any flow rate between the normal and the emphysema group. CONCLUSION: Airflow standardised lung sound intensity does not differ between normal and emphysematous subjects. This suggests that the auscultatory finding of diminished breath sounds during the regular physical examination in patients with emphysema is due predominantly to airflow limitation. Images PMID:1440459

  3. International perception of lung sounds : a comparison of classification across some European borders

    NARCIS (Netherlands)

    Aviles-Solis, Juan Carlos; Vanbelle, Sophie; Halvorsen, Peder A; Francis, Nick; Cals, Jochen W L; Andreeva, Elena A; Marques, Alda; Piirilä, Päivi; Pasterkamp, Hans; Melbye, Hasse

    2017-01-01

    Introduction: Lung auscultation is helpful in the diagnosis of lung and heart diseases; however, the diagnostic value of lung sounds may be questioned due to interobserver variation. This situation may also impair clinical research in this area to generate evidence-based knowledge about the role

  4. International perception of lung sounds: a comparison of classification across some European borders

    OpenAIRE

    Aviles Solis, Juan Carlos; Vanbelle, Sophie; Halvorsen, Peder Andreas; Francis, Nick; Cals, Jochem W L; Andreeva, Elena A; Marques, Alda; Piirila, Paivi; Pasterkamp, Hans; Melbye, Hasse

    2017-01-01

    Source at http://dx.doi.org/10.1136/bmjresp-2017-000250 Introduction: Lung auscultation is helpful in the diagnosis of lung and heart diseases; however, the diagnostic value of lung sounds may be questioned due to interobserver variation. This situation may also impair clinical research in this area to generate evidence-based knowledge about the role that chest auscultation has in a modern clinical setting. The recording and visual display of lung sounds is a method that is both repeatab...

  5. [Study for lung sound acquisition module based on ARM and Linux].

    Science.gov (United States)

    Lu, Qiang; Li, Wenfeng; Zhang, Xixue; Li, Junmin; Liu, Longqing

    2011-07-01

    A acquisition module with ARM and Linux as a core was developed. This paper presents the hardware configuration and the software design. It is shown that the module can extract human lung sound reliably and effectively.

  6. Classification of lung sounds using higher-order statistics: A divide-and-conquer approach.

    Science.gov (United States)

    Naves, Raphael; Barbosa, Bruno H G; Ferreira, Danton D

    2016-06-01

    Lung sound auscultation is one of the most commonly used methods to evaluate respiratory diseases. However, the effectiveness of this method depends on the physician's training. If the physician does not have the proper training, he/she will be unable to distinguish between normal and abnormal sounds generated by the human body. Thus, the aim of this study was to implement a pattern recognition system to classify lung sounds. We used a dataset composed of five types of lung sounds: normal, coarse crackle, fine crackle, monophonic and polyphonic wheezes. We used higher-order statistics (HOS) to extract features (second-, third- and fourth-order cumulants), Genetic Algorithms (GA) and Fisher's Discriminant Ratio (FDR) to reduce dimensionality, and k-Nearest Neighbors and Naive Bayes classifiers to recognize the lung sound events in a tree-based system. We used the cross-validation procedure to analyze the classifiers performance and the Tukey's Honestly Significant Difference criterion to compare the results. Our results showed that the Genetic Algorithms outperformed the Fisher's Discriminant Ratio for feature selection. Moreover, each lung class had a different signature pattern according to their cumulants showing that HOS is a promising feature extraction tool for lung sounds. Besides, the proposed divide-and-conquer approach can accurately classify different types of lung sounds. The classification accuracy obtained by the best tree-based classifier was 98.1% for classification accuracy on training, and 94.6% for validation data. The proposed approach achieved good results even using only one feature extraction tool (higher-order statistics). Additionally, the implementation of the proposed classifier in an embedded system is feasible. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Using K-Nearest Neighbor Classification to Diagnose Abnormal Lung Sounds

    Directory of Open Access Journals (Sweden)

    Chin-Hsing Chen

    2015-06-01

    Full Text Available A reported 30% of people worldwide have abnormal lung sounds, including crackles, rhonchi, and wheezes. To date, the traditional stethoscope remains the most popular tool used by physicians to diagnose such abnormal lung sounds, however, many problems arise with the use of a stethoscope, including the effects of environmental noise, the inability to record and store lung sounds for follow-up or tracking, and the physician’s subjective diagnostic experience. This study has developed a digital stethoscope to help physicians overcome these problems when diagnosing abnormal lung sounds. In this digital system, mel-frequency cepstral coefficients (MFCCs were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation. Finally, the K-nearest neighbor method was used to classify the lung sounds. The proposed system can also be used for home care: if the percentage of abnormal lung sound frames is > 30% of the whole test signal, the system can automatically warn the user to visit a physician for diagnosis. We also used bend sensors together with an amplification circuit, Bluetooth, and a microcontroller to implement a respiration detector. The respiratory signal extracted by the bend sensors can be transmitted to the computer via Bluetooth to calculate the respiratory cycle, for real-time assessment. If an abnormal status is detected, the device will warn the user automatically. Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications.

  8. A comprehensive computational model of sound transmission through the porcine lung.

    Science.gov (United States)

    Dai, Zoujun; Peng, Ying; Henry, Brian M; Mansy, Hansen A; Sandler, Richard H; Royston, Thomas J

    2014-09-01

    A comprehensive computational simulation model of sound transmission through the porcine lung is introduced and experimentally evaluated. This "subject-specific" model utilizes parenchymal and major airway geometry derived from x-ray CT images. The lung parenchyma is modeled as a poroviscoelastic material using Biot theory. A finite element (FE) mesh of the lung that includes airway detail is created and used in comsol FE software to simulate the vibroacoustic response of the lung to sound input at the trachea. The FE simulation model is validated by comparing simulation results to experimental measurements using scanning laser Doppler vibrometry on the surface of an excised, preserved lung. The FE model can also be used to calculate and visualize vibroacoustic pressure and motion inside the lung and its airways caused by the acoustic input. The effect of diffuse lung fibrosis and of a local tumor on the lung acoustic response is simulated and visualized using the FE model. In the future, this type of visualization can be compared and matched with experimentally obtained elastographic images to better quantify regional lung material properties to noninvasively diagnose and stage disease and response to treatment.

  9. Machine learning analysis of binaural rowing sounds

    DEFF Research Database (Denmark)

    Johard, Leonard; Ruffaldi, Emanuele; Hoffmann, Pablo F.

    2011-01-01

    Techniques for machine hearing are increasing their potentiality due to new application domains. In this work we are addressing the analysis of rowing sounds in natural context for the purpose of supporting a training system based on virtual environments. This paper presents the acquisition metho...... methodology and the evaluation of different machine learning techniques for classifying rowing-sound data. We see that a combination of principal component analysis and shallow networks perform equally well as deep architectures, while being much faster to train.......Techniques for machine hearing are increasing their potentiality due to new application domains. In this work we are addressing the analysis of rowing sounds in natural context for the purpose of supporting a training system based on virtual environments. This paper presents the acquisition...

  10. International perception of lung sounds: a comparison of classification across some European borders.

    Science.gov (United States)

    Aviles-Solis, Juan Carlos; Vanbelle, Sophie; Halvorsen, Peder A; Francis, Nick; Cals, Jochen W L; Andreeva, Elena A; Marques, Alda; Piirilä, Päivi; Pasterkamp, Hans; Melbye, Hasse

    2017-01-01

    Lung auscultation is helpful in the diagnosis of lung and heart diseases; however, the diagnostic value of lung sounds may be questioned due to interobserver variation. This situation may also impair clinical research in this area to generate evidence-based knowledge about the role that chest auscultation has in a modern clinical setting. The recording and visual display of lung sounds is a method that is both repeatable and feasible to use in large samples, and the aim of this study was to evaluate interobserver agreement using this method. With a microphone in a stethoscope tube, we collected digital recordings of lung sounds from six sites on the chest surface in 20 subjects aged 40 years or older with and without lung and heart diseases. A total of 120 recordings and their spectrograms were independently classified by 28 observers from seven different countries. We employed absolute agreement and kappa coefficients to explore interobserver agreement in classifying crackles and wheezes within and between subgroups of four observers. When evaluating agreement on crackles (inspiratory or expiratory) in each subgroup, observers agreed on between 65% and 87% of the cases. Conger's kappa ranged from 0.20 to 0.58 and four out of seven groups reached a kappa of ≥0.49. In the classification of wheezes, we observed a probability of agreement between 69% and 99.6% and kappa values from 0.09 to 0.97. Four out of seven groups reached a kappa ≥0.62. The kappa values we observed in our study ranged widely but, when addressing its limitations, we find the method of recording and presenting lung sounds with spectrograms sufficient for both clinic and research. Standardisation of terminology across countries would improve international communication on lung auscultation findings.

  11. The effect of methacholine-induced acute airway narrowing on lung sounds in normal and asthmatic subjects

    NARCIS (Netherlands)

    Schreur, H. J.; Vanderschoot, J.; Zwinderman, A. H.; Dijkman, J. H.; Sterk, P. J.

    1995-01-01

    The association between lung sound alterations and airways obstruction has long been recognized in clinical practice, but the precise pathophysiological mechanisms of this relationship have not been determined. Therefore, we examined the changes in lung sounds at well-defined levels of

  12. Artificial intelligence techniques used in respiratory sound analysis--a systematic review.

    Science.gov (United States)

    Palaniappan, Rajkumar; Sundaraj, Kenneth; Sundaraj, Sebastian

    2014-02-01

    Artificial intelligence (AI) has recently been established as an alternative method to many conventional methods. The implementation of AI techniques for respiratory sound analysis can assist medical professionals in the diagnosis of lung pathologies. This article highlights the importance of AI techniques in the implementation of computer-based respiratory sound analysis. Articles on computer-based respiratory sound analysis using AI techniques were identified by searches conducted on various electronic resources, such as the IEEE, Springer, Elsevier, PubMed, and ACM digital library databases. Brief descriptions of the types of respiratory sounds and their respective characteristics are provided. We then analyzed each of the previous studies to determine the specific respiratory sounds/pathology analyzed, the number of subjects, the signal processing method used, the AI techniques used, and the performance of the AI technique used in the analysis of respiratory sounds. A detailed description of each of these studies is provided. In conclusion, this article provides recommendations for further advancements in respiratory sound analysis.

  13. Estimating the diffuseness of sound fields: A wavenumber analysis method

    DEFF Research Database (Denmark)

    Nolan, Melanie; Davy, John L.; Brunskog, Jonas

    2017-01-01

    The concept of a diffuse sound field is widely used in the analysis of sound in enclosures. The diffuse sound field is generally described as composed of plane waves with random phases, which wave number vectors are uniformly distributed over all angles of incidence. In this study, an interpretat...

  14. A Lexical Analysis of Environmental Sound Categories

    Science.gov (United States)

    Houix, Olivier; Lemaitre, Guillaume; Misdariis, Nicolas; Susini, Patrick; Urdapilleta, Isabel

    2012-01-01

    In this article we report on listener categorization of meaningful environmental sounds. A starting point for this study was the phenomenological taxonomy proposed by Gaver (1993b). In the first experimental study, 15 participants classified 60 environmental sounds and indicated the properties shared by the sounds in each class. In a second…

  15. Sound

    CERN Document Server

    Robertson, William C

    2003-01-01

    Muddled about what makes music? Stuck on the study of harmonics? Dumbfounded by how sound gets around? Now you no longer have to struggle to teach concepts you really don t grasp yourself. Sound takes an intentionally light touch to help out all those adults science teachers, parents wanting to help with homework, home-schoolers seeking necessary scientific background to teach middle school physics with confidence. The book introduces sound waves and uses that model to explain sound-related occurrences. Starting with the basics of what causes sound and how it travels, you'll learn how musical instruments work, how sound waves add and subtract, how the human ear works, and even why you can sound like a Munchkin when you inhale helium. Sound is the fourth book in the award-winning Stop Faking It! Series, published by NSTA Press. Like the other popular volumes, it is written by irreverent educator Bill Robertson, who offers this Sound recommendation: One of the coolest activities is whacking a spinning metal rod...

  16. Analysis and Synthesis of Musical Instrument Sounds

    Science.gov (United States)

    Beauchamp, James W.

    For synthesizing a wide variety of musical sounds, it is important to understand which acoustic properties of musical instrument sounds are related to specific perceptual features. Some properties are obvious: Amplitude and fundamental frequency easily control loudness and pitch. Other perceptual features are related to sound spectra and how they vary with time. For example, tonal "brightness" is strongly connected to the centroid or tilt of a spectrum. "Attack impact" (sometimes called "bite" or "attack sharpness") is strongly connected to spectral features during the first 20-100 ms of sound, as well as the rise time of the sound. Tonal "warmth" is connected to spectral features such as "incoherence" or "inharmonicity."

  17. Analysis of the acoustic sound in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Tetsuro; Hara, Akira; Kusakari, Jun; Yoshioka, Hiroshi; Niitsu, Mamoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Ase, Yuji

    1999-04-01

    The noise level and power spectra of the acoustic sound exposed during the examination of Magnetic Resonance Imaging (MRI) using a MRI scanner (Philips Gyroscan 1.5 T) were measured at the position of the human auricle. The overall noise levels on T1-weighted images and T2-weighted images with Spin Echo were 105 dB and 98 dB, respectively. The overall noise level on T2-weighted images with Turbo Spin Echo was 110 dB. Fourier analysis revealed energy peaks ranging from 225 to 325 Hz and a steep high frequency cutoff for each pulse sequence. The MRI noise was not likely to cause permanent threshold shift. However, because of the inter-subject variation in susceptibility to acoustic trauma and to exclude the anxiety in patients, ear protectors were recommended for all patients during MRI testing. (author)

  18. Analysis, Synthesis, and Perception of Musical Sounds The Sound of Music

    CERN Document Server

    Beauchamp, James W

    2007-01-01

    Analysis, Synthesis, and Perception of Musical Sounds contains a detailed treatment of basic methods for analysis and synthesis of musical sounds, including the phase vocoder method, the McAulay-Quatieri frequency-tracking method, the constant-Q transform, and methods for pitch tracking with several examples shown. Various aspects of musical sound spectra such as spectral envelope, spectral centroid, spectral flux, and spectral irregularity are defined and discussed. One chapter is devoted to the control and synthesis of spectral envelopes. Two advanced methods of analysis/synthesis are given: "Sines Plus Transients Plus Noise" and "Spectrotemporal Reassignment" are covered. Methods for timbre morphing are given. The last two chapters discuss the perception of musical sounds based on discrimination and multidimensional scaling timbre models.

  19. Sound analysis of a cup drum

    International Nuclear Information System (INIS)

    Kim, Kun ho

    2012-01-01

    The International Young Physicists’ Tournament (IYPT) is a worldwide tournament that evaluates a high-school student's ability to solve various physics conundrums that have not been fully resolved in the past. The research presented here is my solution to the cup drum problem. The physics behind a cup drum has never been explored or modelled. A cup drum is a musical instrument that can generate different frequencies and amplitudes depending on the location of a cup held upside-down over, on or under a water surface. The tapping sound of a cup drum can be divided into two components: standing waves and plate vibration. By individually researching the nature of these two sounds, I arrived at conclusions that could accurately predict the frequencies in most cases. When the drum is very close to the surface, qualitative explanations are given. In addition, I examined the trend of the tapping sound amplitude at various distances and qualitatively explained the experimental results. (paper)

  20. Analysis of chewing sounds for dietary monitoring

    NARCIS (Netherlands)

    Amft, O.D.; Stäger, M.; Lukowicz, P.; Tröster, G.

    2005-01-01

    The paper reports the results of the first stage of our work on an automatic dietary monitoring system. The work is part of a large European project on using ubiquitous systems to support healthy lifestyle and cardiovascular disease prevention. We demonstrate that sound from the user's mouth can be

  1. Usability of Computerized Lung Auscultation-Sound Software (CLASS) for learning pulmonary auscultation.

    Science.gov (United States)

    Machado, Ana; Oliveira, Ana; Jácome, Cristina; Pereira, Marco; Moreira, José; Rodrigues, João; Aparício, José; Jesus, Luis M T; Marques, Alda

    2018-04-01

    The mastering of pulmonary auscultation requires complex acoustic skills. Computer-assisted learning tools (CALTs) have potential to enhance the learning of these skills; however, few have been developed for this purpose and do not integrate all the required features. Thus, this study aimed to assess the usability of a new CALT for learning pulmonary auscultation. Computerized Lung Auscultation-Sound Software (CLASS) usability was assessed by eight physiotherapy students using computer screen recordings, think-aloud reports, and facial expressions. Time spent in each task, frequency of messages and facial expressions, number of clicks and problems reported were counted. The timelines of the three methods used were matched/synchronized and analyzed. The tasks exercises and annotation of respiratory sounds were the ones requiring more clicks (median 132, interquartile range [23-157]; 93 [53-155]; 91 [65-104], respectively) and where most errors (19; 37; 15%, respectively) and problems (n = 7; 6; 3, respectively) were reported. Each participant reported a median of 6 problems, with a total of 14 different problems found, mainly related with CLASS functionalities (50%). Smile was the only facial expression presented in all tasks (n = 54). CLASS is the only CALT available that meets all the required features for learning pulmonary auscultation. The combination of the three usability methods identified advantages/disadvantages of CLASS and offered guidance for future developments, namely in annotations and exercises. This will allow the improvement of CLASS and enhance students' activities for learning pulmonary auscultation skills.

  2. Usefulness of the second heart sound for predicting pulmonary hypertension in patients with interstitial lung disease

    Directory of Open Access Journals (Sweden)

    Sandra de Barros Cobra

    Full Text Available CONTEXT AND OBJECTIVE: P2 hyperphonesis is considered to be a valuable finding in semiological diagnoses of pulmonary hypertension (PH. The aim here was to evaluate the accuracy of the pulmonary component of second heart sounds for predicting PH in patients with interstitial lung disease. DESIGN AND SETTING: Cross-sectional study at the University of Brasilia and Hospital de Base do Distrito Federal. METHODS: Heart sounds were acquired using an electronic stethoscope and were analyzed using phonocardiography. Clinical signs suggestive of PH, such as second heart sound (S2 in pulmonary area louder than in aortic area; P2 > A2 in pulmonary area and P2 present in mitral area, were compared with Doppler echocardiographic parameters suggestive of PH. Sensitivity (S, specificity (Sp and positive (LR+ and negative (LR- likelihood ratios were evaluated. RESULTS: There was no significant correlation between S2 or P2 amplitude and PASP (pulmonary artery systolic pressure (P = 0.185 and 0.115; P= 0.13 and 0.34, respectively. Higher S2 in pulmonary area than in aortic area, compared with all the criteria suggestive of PH, showed S = 60%, Sp= 22%; LR+ = 0.7; LR- = 1.7; while P2> A2 showed S= 57%, Sp = 39%; LR+ = 0.9; LR- = 1.1; and P2 in mitral area showed: S= 68%, Sp = 41%; LR+ = 1.1; LR- = 0.7. All these signals together showed: S= 50%, Sp = 56%. CONCLUSIONS: The semiological signs indicative of PH presented low sensitivity and specificity levels for clinically diagnosing this comorbidity.

  3. THE MODEL FOR DIEGETIC ANALYSIS OF SOUNDS IN SCREEN MEDIA

    Directory of Open Access Journals (Sweden)

    Denikin Anton A.

    2013-12-01

    Full Text Available This article includes the analysis of the relationship between representational visual spaces and sounds in screen media. The methodology presented in this paper can be used for the accurate classification and differentiation for screen sounds, as well as for the general analysis of the specific sound of screen media. For this, the concept of «diegesis» is used. It allows us to analyze the spatial specificity of audiovisual images in cinematographic works and the spatial-functional interactive action in video games and others multimedia.

  4. Automatic adventitious respiratory sound analysis: A systematic review.

    Science.gov (United States)

    Pramono, Renard Xaviero Adhi; Bowyer, Stuart; Rodriguez-Villegas, Esther

    2017-01-01

    Automatic detection or classification of adventitious sounds is useful to assist physicians in diagnosing or monitoring diseases such as asthma, Chronic Obstructive Pulmonary Disease (COPD), and pneumonia. While computerised respiratory sound analysis, specifically for the detection or classification of adventitious sounds, has recently been the focus of an increasing number of studies, a standardised approach and comparison has not been well established. To provide a review of existing algorithms for the detection or classification of adventitious respiratory sounds. This systematic review provides a complete summary of methods used in the literature to give a baseline for future works. A systematic review of English articles published between 1938 and 2016, searched using the Scopus (1938-2016) and IEEExplore (1984-2016) databases. Additional articles were further obtained by references listed in the articles found. Search terms included adventitious sound detection, adventitious sound classification, abnormal respiratory sound detection, abnormal respiratory sound classification, wheeze detection, wheeze classification, crackle detection, crackle classification, rhonchi detection, rhonchi classification, stridor detection, stridor classification, pleural rub detection, pleural rub classification, squawk detection, and squawk classification. Only articles were included that focused on adventitious sound detection or classification, based on respiratory sounds, with performance reported and sufficient information provided to be approximately repeated. Investigators extracted data about the adventitious sound type analysed, approach and level of analysis, instrumentation or data source, location of sensor, amount of data obtained, data management, features, methods, and performance achieved. A total of 77 reports from the literature were included in this review. 55 (71.43%) of the studies focused on wheeze, 40 (51.95%) on crackle, 9 (11.69%) on stridor, 9 (11

  5. A framework for automatic heart sound analysis without segmentation

    Directory of Open Access Journals (Sweden)

    Tungpimolrut Kanokvate

    2011-02-01

    Full Text Available Abstract Background A new framework for heart sound analysis is proposed. One of the most difficult processes in heart sound analysis is segmentation, due to interference form murmurs. Method Equal number of cardiac cycles were extracted from heart sounds with different heart rates using information from envelopes of autocorrelation functions without the need to label individual fundamental heart sounds (FHS. The complete method consists of envelope detection, calculation of cardiac cycle lengths using auto-correlation of envelope signals, features extraction using discrete wavelet transform, principal component analysis, and classification using neural network bagging predictors. Result The proposed method was tested on a set of heart sounds obtained from several on-line databases and recorded with an electronic stethoscope. Geometric mean was used as performance index. Average classification performance using ten-fold cross-validation was 0.92 for noise free case, 0.90 under white noise with 10 dB signal-to-noise ratio (SNR, and 0.90 under impulse noise up to 0.3 s duration. Conclusion The proposed method showed promising results and high noise robustness to a wide range of heart sounds. However, more tests are needed to address any bias that may have been introduced by different sources of heart sounds in the current training set, and to concretely validate the method. Further work include building a new training set recorded from actual patients, then further evaluate the method based on this new training set.

  6. Heart sounds analysis using probability assessment

    Czech Academy of Sciences Publication Activity Database

    Plešinger, Filip; Viščor, Ivo; Halámek, Josef; Jurčo, Juraj; Jurák, Pavel

    2017-01-01

    Roč. 38, č. 8 (2017), s. 1685-1700 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2034; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : heart sounds * FFT * machine learning * signal averaging * probability assessment Subject RIV: FS - Medical Facilities ; Equipment OBOR OECD: Medical engineering Impact factor: 2.058, year: 2016

  7. Heart Sound Biometric System Based on Marginal Spectrum Analysis

    Science.gov (United States)

    Zhao, Zhidong; Shen, Qinqin; Ren, Fangqin

    2013-01-01

    This work presents a heart sound biometric system based on marginal spectrum analysis, which is a new feature extraction technique for identification purposes. This heart sound identification system is comprised of signal acquisition, pre-processing, feature extraction, training, and identification. Experiments on the selection of the optimal values for the system parameters are conducted. The results indicate that the new spectrum coefficients result in a significant increase in the recognition rate of 94.40% compared with that of the traditional Fourier spectrum (84.32%) based on a database of 280 heart sounds from 40 participants. PMID:23429515

  8. Heart sounds analysis using probability assessment.

    Science.gov (United States)

    Plesinger, F; Viscor, I; Halamek, J; Jurco, J; Jurak, P

    2017-07-31

    This paper describes a method for automated discrimination of heart sounds recordings according to the Physionet Challenge 2016. The goal was to decide if the recording refers to normal or abnormal heart sounds or if it is not possible to decide (i.e. 'unsure' recordings). Heart sounds S1 and S2 are detected using amplitude envelopes in the band 15-90 Hz. The averaged shape of the S1/S2 pair is computed from amplitude envelopes in five different bands (15-90 Hz; 55-150 Hz; 100-250 Hz; 200-450 Hz; 400-800 Hz). A total of 53 features are extracted from the data. The largest group of features is extracted from the statistical properties of the averaged shapes; other features are extracted from the symmetry of averaged shapes, and the last group of features is independent of S1 and S2 detection. Generated features are processed using logical rules and probability assessment, a prototype of a new machine-learning method. The method was trained using 3155 records and tested on 1277 hidden records. It resulted in a training score of 0.903 (sensitivity 0.869, specificity 0.937) and a testing score of 0.841 (sensitivity 0.770, specificity 0.913). The revised method led to a test score of 0.853 in the follow-up phase of the challenge. The presented solution achieved 7th place out of 48 competing entries in the Physionet Challenge 2016 (official phase). In addition, the PROBAfind software for probability assessment was introduced.

  9. A noise reduction technique based on nonlinear kernel function for heart sound analysis.

    Science.gov (United States)

    Mondal, Ashok; Saxena, Ishan; Tang, Hong; Banerjee, Poulami

    2017-02-13

    The main difficulty encountered in interpretation of cardiac sound is interference of noise. The contaminated noise obscures the relevant information which are useful for recognition of heart diseases. The unwanted signals are produced mainly by lungs and surrounding environment. In this paper, a novel heart sound de-noising technique has been introduced based on a combined framework of wavelet packet transform (WPT) and singular value decomposition (SVD). The most informative node of wavelet tree is selected on the criteria of mutual information measurement. Next, the coefficient corresponding to the selected node is processed by SVD technique to suppress noisy component from heart sound signal. To justify the efficacy of the proposed technique, several experiments have been conducted with heart sound dataset, including normal and pathological cases at different signal to noise ratios. The significance of the method is validated by statistical analysis of the results. The biological information preserved in de-noised heart sound (HS) signal is evaluated by k-means clustering algorithm and Fit Factor calculation. The overall results show that proposed method is superior than the baseline methods.

  10. Sound Classification in Hearing Aids Inspired by Auditory Scene Analysis

    Science.gov (United States)

    Büchler, Michael; Allegro, Silvia; Launer, Stefan; Dillier, Norbert

    2005-12-01

    A sound classification system for the automatic recognition of the acoustic environment in a hearing aid is discussed. The system distinguishes the four sound classes "clean speech," "speech in noise," "noise," and "music." A number of features that are inspired by auditory scene analysis are extracted from the sound signal. These features describe amplitude modulations, spectral profile, harmonicity, amplitude onsets, and rhythm. They are evaluated together with different pattern classifiers. Simple classifiers, such as rule-based and minimum-distance classifiers, are compared with more complex approaches, such as Bayes classifier, neural network, and hidden Markov model. Sounds from a large database are employed for both training and testing of the system. The achieved recognition rates are very high except for the class "speech in noise." Problems arise in the classification of compressed pop music, strongly reverberated speech, and tonal or fluctuating noises.

  11. Heart sound segmentation of pediatric auscultations using wavelet analysis.

    Science.gov (United States)

    Castro, Ana; Vinhoza, Tiago T V; Mattos, Sandra S; Coimbra, Miguel T

    2013-01-01

    Auscultation is widely applied in clinical activity, nonetheless sound interpretation is dependent on clinician training and experience. Heart sound features such as spatial loudness, relative amplitude, murmurs, and localization of each component may be indicative of pathology. In this study we propose a segmentation algorithm to extract heart sound components (S1 and S2) based on it's time and frequency characteristics. This algorithm takes advantage of the knowledge of the heart cycle times (systolic and diastolic periods) and of the spectral characteristics of each component, through wavelet analysis. Data collected in a clinical environment, and annotated by a clinician was used to assess algorithm's performance. Heart sound components were correctly identified in 99.5% of the annotated events. S1 and S2 detection rates were 90.9% and 93.3% respectively. The median difference between annotated and detected events was of 33.9 ms.

  12. Analysis of Damped Mass-Spring Systems for Sound Synthesis

    Directory of Open Access Journals (Sweden)

    Don Morgan

    2009-01-01

    Full Text Available There are many ways of synthesizing sound on a computer. The method that we consider, called a mass-spring system, synthesizes sound by simulating the vibrations of a network of interconnected masses, springs, and dampers. Numerical methods are required to approximate the differential equation of a mass-spring system. The standard numerical method used in implementing mass-spring systems for use in sound synthesis is the symplectic Euler method. Implementers and users of mass-spring systems should be aware of the limitations of the numerical methods used; in particular we are interested in the stability and accuracy of the numerical methods used. We present an analysis of the symplectic Euler method that shows the conditions under which the method is stable and the accuracy of the decay rates and frequencies of the sounds produced.

  13. Intelligent Systems Approaches to Product Sound Quality Analysis

    Science.gov (United States)

    Pietila, Glenn M.

    As a product market becomes more competitive, consumers become more discriminating in the way in which they differentiate between engineered products. The consumer often makes a purchasing decision based on the sound emitted from the product during operation by using the sound to judge quality or annoyance. Therefore, in recent years, many sound quality analysis tools have been developed to evaluate the consumer preference as it relates to a product sound and to quantify this preference based on objective measurements. This understanding can be used to direct a product design process in order to help differentiate the product from competitive products or to establish an impression on consumers regarding a product's quality or robustness. The sound quality process is typically a statistical tool that is used to model subjective preference, or merit score, based on objective measurements, or metrics. In this way, new product developments can be evaluated in an objective manner without the laborious process of gathering a sample population of consumers for subjective studies each time. The most common model used today is the Multiple Linear Regression (MLR), although recently non-linear Artificial Neural Network (ANN) approaches are gaining popularity. This dissertation will review publicly available published literature and present additional intelligent systems approaches that can be used to improve on the current sound quality process. The focus of this work is to address shortcomings in the current paired comparison approach to sound quality analysis. This research will propose a framework for an adaptive jury analysis approach as an alternative to the current Bradley-Terry model. The adaptive jury framework uses statistical hypothesis testing to focus on sound pairings that are most interesting and is expected to address some of the restrictions required by the Bradley-Terry model. It will also provide a more amicable framework for an intelligent systems approach

  14. Validity and reliability of acoustic analysis of respiratory sounds in infants

    Science.gov (United States)

    Elphick, H; Lancaster, G; Solis, A; Majumdar, A; Gupta, R; Smyth, R

    2004-01-01

    Objective: To investigate the validity and reliability of computerised acoustic analysis in the detection of abnormal respiratory noises in infants. Methods: Blinded, prospective comparison of acoustic analysis with stethoscope examination. Validity and reliability of acoustic analysis were assessed by calculating the degree of observer agreement using the κ statistic with 95% confidence intervals (CI). Results: 102 infants under 18 months were recruited. Convergent validity for agreement between stethoscope examination and acoustic analysis was poor for wheeze (κ = 0.07 (95% CI, –0.13 to 0.26)) and rattles (κ = 0.11 (–0.05 to 0.27)) and fair for crackles (κ = 0.36 (0.18 to 0.54)). Both the stethoscope and acoustic analysis distinguished well between sounds (discriminant validity). Agreement between observers for the presence of wheeze was poor for both stethoscope examination and acoustic analysis. Agreement for rattles was moderate for the stethoscope but poor for acoustic analysis. Agreement for crackles was moderate using both techniques. Within-observer reliability for all sounds using acoustic analysis was moderate to good. Conclusions: The stethoscope is unreliable for assessing respiratory sounds in infants. This has important implications for its use as a diagnostic tool for lung disorders in infants, and confirms that it cannot be used as a gold standard. Because of the unreliability of the stethoscope, the validity of acoustic analysis could not be demonstrated, although it could discriminate between sounds well and showed good within-observer reliability. For acoustic analysis, targeted training and the development of computerised pattern recognition systems may improve reliability so that it can be used in clinical practice. PMID:15499065

  15. Automatic adventitious respiratory sound analysis: A systematic review.

    Directory of Open Access Journals (Sweden)

    Renard Xaviero Adhi Pramono

    Full Text Available Automatic detection or classification of adventitious sounds is useful to assist physicians in diagnosing or monitoring diseases such as asthma, Chronic Obstructive Pulmonary Disease (COPD, and pneumonia. While computerised respiratory sound analysis, specifically for the detection or classification of adventitious sounds, has recently been the focus of an increasing number of studies, a standardised approach and comparison has not been well established.To provide a review of existing algorithms for the detection or classification of adventitious respiratory sounds. This systematic review provides a complete summary of methods used in the literature to give a baseline for future works.A systematic review of English articles published between 1938 and 2016, searched using the Scopus (1938-2016 and IEEExplore (1984-2016 databases. Additional articles were further obtained by references listed in the articles found. Search terms included adventitious sound detection, adventitious sound classification, abnormal respiratory sound detection, abnormal respiratory sound classification, wheeze detection, wheeze classification, crackle detection, crackle classification, rhonchi detection, rhonchi classification, stridor detection, stridor classification, pleural rub detection, pleural rub classification, squawk detection, and squawk classification.Only articles were included that focused on adventitious sound detection or classification, based on respiratory sounds, with performance reported and sufficient information provided to be approximately repeated.Investigators extracted data about the adventitious sound type analysed, approach and level of analysis, instrumentation or data source, location of sensor, amount of data obtained, data management, features, methods, and performance achieved.A total of 77 reports from the literature were included in this review. 55 (71.43% of the studies focused on wheeze, 40 (51.95% on crackle, 9 (11.69% on stridor, 9

  16. Analysis of the drilling sound in maxillo-facial surgery

    DEFF Research Database (Denmark)

    Hoffmann, Pablo F.; Gosselin, Florian; Taha, Farid

    2009-01-01

    Auditory feedback can have a great potential in surgical simulators that aim at training skills associated to the correct interpretation of acoustic information. Here, we present a preliminary analysis of the sound that is produced by the drilling procedure in a maxillo-facial surgery when...... performed by expert surgeons. The motivation of this work is to find relevant acoustic parameters that allow for an efficient synthesis method of the drilling sound and to set the basis of the audio component in the simulator so that expert surgical drilling can effectively be conveyed to users...

  17. Analysis of Respiratory Sounds: State of the Art

    Directory of Open Access Journals (Sweden)

    Sandra Reichert

    2008-01-01

    Full Text Available Objective This paper describes state of the art, scientific publications and ongoing research related to the methods of analysis of respiratory sounds. Methods and material Review of the current medical and technological literature using Pubmed and personal experience. Results The study includes a description of the various techniques that are being used to collect auscultation sounds, a physical description of known pathologic sounds for which automatic detection tools were developed. Modern tools are based on artificial intelligence and on technics such as artificial neural networks, fuzzy systems, and genetic algorithms… Conclusion The next step will consist in finding new markers so as to increase the efficiency of decision aid algorithms and tools.

  18. Theoretical analysis of sound transmission loss through graphene sheets

    International Nuclear Information System (INIS)

    Natsuki, Toshiaki; Ni, Qing-Qing

    2014-01-01

    We examine the potential of using graphene sheets (GSs) as sound insulating materials that can be used for nano-devices because of their small size, super electronic, and mechanical properties. In this study, a theoretical analysis is proposed to predict the sound transmission loss through multi-layered GSs, which are formed by stacks of GS and bound together by van der Waals (vdW) forces between individual layers. The result shows that the resonant frequencies of the sound transmission loss occur in the multi-layered GSs and the values are very high. Based on the present analytical solution, we predict the acoustic insulation property for various layers of sheets under both normal incident wave and acoustic field of random incidence source. The scheme could be useful in vibration absorption application of nano devices and materials

  19. Theoretical analysis of sound transmission loss through graphene sheets

    Energy Technology Data Exchange (ETDEWEB)

    Natsuki, Toshiaki, E-mail: natsuki@shinshu-u.ac.jp [Faculty of Textile Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda 386-8567 (Japan); Institute of Carbon Science and Technology, Shinshu University, 4-17-1 Wakasato, Nagano 380-8553 (Japan); Ni, Qing-Qing [Faculty of Textile Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda 386-8567 (Japan)

    2014-11-17

    We examine the potential of using graphene sheets (GSs) as sound insulating materials that can be used for nano-devices because of their small size, super electronic, and mechanical properties. In this study, a theoretical analysis is proposed to predict the sound transmission loss through multi-layered GSs, which are formed by stacks of GS and bound together by van der Waals (vdW) forces between individual layers. The result shows that the resonant frequencies of the sound transmission loss occur in the multi-layered GSs and the values are very high. Based on the present analytical solution, we predict the acoustic insulation property for various layers of sheets under both normal incident wave and acoustic field of random incidence source. The scheme could be useful in vibration absorption application of nano devices and materials.

  20. Tipping point analysis of a large ocean ambient sound record

    Science.gov (United States)

    Livina, Valerie N.; Harris, Peter; Brower, Albert; Wang, Lian; Sotirakopoulos, Kostas; Robinson, Stephen

    2017-04-01

    We study a long (2003-2015) high-resolution (250Hz) sound pressure record provided by the Comprehensive Nuclear-Test-Ban Treaty Organisation (CTBTO) from the hydro-acoustic station Cape Leeuwin (Australia). We transform the hydrophone waveforms into five bands of 10-min-average sound pressure levels (including the third-octave band) and apply tipping point analysis techniques [1-3]. We report the results of the analysis of fluctuations and trends in the data and discuss the BigData challenges in processing this record, including handling data segments of large size and possible HPC solutions. References: [1] Livina et al, GRL 2007, [2] Livina et al, Climate of the Past 2010, [3] Livina et al, Chaos 2015.

  1. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    Science.gov (United States)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  2. Using quantitative breath sound measurements to predict lung function following resection

    Directory of Open Access Journals (Sweden)

    Keus Leendert

    2010-10-01

    Full Text Available Abstract Background Predicting postoperative lung function is important for estimating the risk of complications and long-term disability after pulmonary resection. We investigated the capability of vibration response imaging (VRI as an alternative to lung scintigraphy for prediction of postoperative lung function in patients with intrathoracic malignancies. Methods Eighty-five patients with intrathoracic malignancies, considered candidates for lung resection, were prospectively studied. The projected postoperative (ppo lung function was calculated using: perfusion scintigraphy, ventilation scintigraphy, and VRI. Two sets of assessments made: one for lobectomy and one for pneumonectomy. Clinical concordance was defined as both methods agreeing that either a patient was or was not a surgical candidate based on a ppoFEV1% and ppoDLCO% > 40%. Results Limits of agreement between scintigraphy and VRI for ppo following lobectomy were -16.47% to 15.08% (mean difference = -0.70%;95%CI = -2.51% to 1.12% and for pneumonectomy were -23.79% to 19.04% (mean difference = -2.38%;95%CI = -4.69% to -0.07%. Clinical concordance between VRI and scintigraphy was 73% for pneumonectomy and 98% for lobectomy. For patients who had surgery and postoperative lung function testing (n = 31, ppoFEV1% using scintigraphic methods correlated with measured postoperative values better than projections using VRI, (adjusted R2 = 0.32 scintigraphy; 0.20 VRI, however the difference between methods failed to reach statistical significance. Limits of agreement between measured FEV1% postoperatively and ppoFEV1% based on perfusion scintigraphy were -16.86% to 23.73% (mean difference = 3.44%;95%CI = -0.29% to 7.16%; based on VRI were -19.56% to 28.99% (mean difference = 4.72%;95%CI = 0.27% to 9.17%. Conclusions Further investigation of VRI as an alternative to lung scintigraphy for prediction of postoperative lung function is warranted.

  3. Statistical Analysis for Subjective and Objective Evaluations of Dental Drill Sounds.

    Directory of Open Access Journals (Sweden)

    Tomomi Yamada

    Full Text Available The sound produced by a dental air turbine handpiece (dental drill can markedly influence the sound environment in a dental clinic. Indeed, many patients report that the sound of a dental drill elicits an unpleasant feeling. Although several manufacturers have attempted to reduce the sound pressure levels produced by dental drills during idling based on ISO 14457, the sound emitted by such drills under active drilling conditions may negatively influence the dental clinic sound environment. The physical metrics related to the unpleasant impressions associated with dental drill sounds have not been determined. In the present study, psychological measurements of dental drill sounds were conducted with the aim of facilitating improvement of the sound environment at dental clinics. Specifically, we examined the impressions elicited by the sounds of 12 types of dental drills in idling and drilling conditions using a semantic differential. The analysis revealed that the impressions of dental drill sounds varied considerably between idling and drilling conditions and among the examined drills. This finding suggests that measuring the sound of a dental drill in idling conditions alone may be insufficient for evaluating the effects of the sound. We related the results of the psychological evaluations to those of measurements of the physical metrics of equivalent continuous A-weighted sound pressure levels (LAeq and sharpness. Factor analysis indicated that impressions of the dental drill sounds consisted of two factors: "metallic and unpleasant" and "powerful". LAeq had a strong relationship with "powerful impression", calculated sharpness was positively related to "metallic impression", and "unpleasant impression" was predicted by the combination of both LAeq and calculated sharpness. The present analyses indicate that, in addition to a reduction in sound pressure level, refining the frequency components of dental drill sounds is important for creating a

  4. Puget Sound steelhead life cycle model analyses - Population Viability Analysis

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This research was initiated by the Puget Sound Steelhead Technical Recovery Team to develop viability criteria for threatened Puget Sound steelhead and to support...

  5. Spectral analysis of musical sounds with emphasis on the piano

    CERN Document Server

    Koenig, David M

    2014-01-01

    There are three parts to this book which addresses the analysis of musical sounds from the viewpoint of someone at the intersection between physicists, engineers, piano technicians, and musicians. The reader is introduced to a variety of waves and a variety of ways of presenting, visualizing, and analyzing them in the first part. A tutorial on the tools used throughout the book accompanies this introduction. The mathematics behind the tools is left to the appendices. Part 2 is a graphical survey of the classical areas of acoustics that pertain to musical instruments: vibrating strings, bars, membranes, and plates. Part 3 is devoted almost exclusively to the piano. Several two- and three-dimensional graphical tools are introduced to study the following characteristics of pianos: individual notes and interactions among them, the missing fundamental, inharmonicity, tuning visualization, the different distribution of harmonic power for the various zones of the piano keyboard, and potential uses for quality contro...

  6. Objective function analysis for electric soundings (VES), transient electromagnetic soundings (TEM) and joint inversion VES/TEM

    Science.gov (United States)

    Bortolozo, Cassiano Antonio; Bokhonok, Oleg; Porsani, Jorge Luís; Monteiro dos Santos, Fernando Acácio; Diogo, Liliana Alcazar; Slob, Evert

    2017-11-01

    Ambiguities in geophysical inversion results are always present. How these ambiguities appear in most cases open to interpretation. It is interesting to investigate ambiguities with regard to the parameters of the models under study. Residual Function Dispersion Map (RFDM) can be used to differentiate between global ambiguities and local minima in the objective function. We apply RFDM to Vertical Electrical Sounding (VES) and TEM Sounding inversion results. Through topographic analysis of the objective function we evaluate the advantages and limitations of electrical sounding data compared with TEM sounding data, and the benefits of joint inversion in comparison with the individual methods. The RFDM analysis proved to be a very interesting tool for understanding the joint inversion method of VES/TEM. Also the advantage of the applicability of the RFDM analyses in real data is explored in this paper to demonstrate not only how the objective function of real data behaves but the applicability of the RFDM approach in real cases. With the analysis of the results, it is possible to understand how the joint inversion can reduce the ambiguity of the methods.

  7. Shape analysis of pulsed second sound in He II

    International Nuclear Information System (INIS)

    Worthington, T.; Yan, J.; Trefny, J.U.

    1976-01-01

    Second sound in He II has been observed using a heat pulse method. At temperatures where well-developed second sound is observed, the entire pulse shape can be understood if heat sources and geometrical effects are properly taken into account. 4 figures

  8. Analysis of acoustic sound signal for ONB measurement

    International Nuclear Information System (INIS)

    Park, S. J.; Kim, H. I.; Han, K. Y.; Chai, H. T.; Park, C.

    2003-01-01

    The onset of nucleate boiling (ONB) was measured in a test fuel bundle composed of several fuel element simulators (FES) by analysing the aquatic sound signals. In order measure ONBs, a hydrophone, a pre-amplifier, and a data acquisition system to acquire/process the aquatic signal was prepared. The acoustic signal generated in the coolant is converted to the current signal through the microphone. When the signal is analyzed in the frequency domain, each sound signal can be identified according to its origin of sound source. As the power is increased to a certain degree, a nucleate boiling is started. The frequent formation and collapse of the void bubbles produce sound signal. By measuring this sound signal one can pinpoint the ONB. Since the signal characteristics is identical for different mass flow rates, this method can be applicable for ascertaining ONB

  9. Maximizing Return From Sound Analysis and Design Practices

    International Nuclear Information System (INIS)

    Bramlette, J.D.

    2002-01-01

    With today's tightening budgets computer applications must provide ''true'' long-term benefit to the company. Businesses are spending large portions of their budgets ''Re-Engineering'' old systems to take advantage of ''new'' technology. But what they are really getting is simply a new interface implementing the same incomplete or poor defined requirements as before. ''True'' benefit can only be gained if sound analysis and design practices are used. WHAT data and processes are required of a system is not the same as HOW the system will be implemented within a company. It is the System Analyst's responsibility to understand the difference between these two concepts. The paper discusses some simple techniques to be used during the Analysis and Design phases of projects, as well as the information gathered and recorded in each phase and how it is transformed between these phases. The paper also covers production application generated using Oracle Designer. Applying these techniques to ''real world'' problems, the applications will meet the needs for today's business and adapt easily to ever-changing business environments

  10. Analysis of sound pressure levels emitted by children's toys.

    Science.gov (United States)

    Sleifer, Pricila; Gonçalves, Maiara Santos; Tomasi, Marinês; Gomes, Erissandra

    2013-06-01

    To verify the levels of sound pressure emitted by non-certified children's toys. Cross-sectional study of sound toys available at popular retail stores of the so-called informal sector. Electronic, mechanical, and musical toys were analyzed. The measurement of each product was carried out by an acoustic engineer in an acoustically isolated booth, by a decibel meter. To obtain the sound parameters of intensity and frequency, the toys were set to produce sounds at a distance of 10 and 50cm from the researcher's ear. The intensity of sound pressure [dB(A)] and the frequency in hertz (Hz) were measured. 48 toys were evaluated. The mean sound pressure 10cm from the ear was 102±10 dB(A), and at 50cm, 94±8 dB(A), with ptoys was above 85dB(A). The frequency ranged from 413 to 6,635Hz, with 56.3% of toys emitting frequency higher than 2,000Hz. The majority of toys assessed in this research emitted a high level of sound pressure.

  11. Heart sounds analysis via esophageal stethoscope system in beagles.

    Science.gov (United States)

    Park, Sang Hi; Shin, Young Duck; Bae, Jin Ho; Kwon, Eun Jung; Lee, Tae-Soo; Shin, Ji-Yun; Kim, Yeong-Cheol; Min, Gyeong-Deuk; Kim, Myoung hwan

    2013-10-01

    Esophageal stethoscope is less invasive and easy to handling. And it gives a lot of information. The purpose of this study is to investigate the correlation of blood pressure and heart sound as measured by esophageal stethoscope. Four male beagles weighing 10 to 12 kg were selected as experimental subjects. After general anesthesia, the esophageal stethoscope was inserted. After connecting the microphone, the heart sounds were visualized and recorded through a self-developed equipment and program. The amplitudes of S1 and S2 were monitored real-time to examine changes as the blood pressure increased and decreased. The relationship between the ratios of S1 to S2 (S1/S2) and changes in blood pressure due to ephedrine was evaluated. The same experiment was performed with different concentration of isoflurane. From S1 and S2 in the inotropics experiment, a high correlation appeared with change in blood pressure in S1. The relationship between S1/S2 and change in blood pressure showed a positive correlation in each experimental subject. In the volatile anesthetics experiment, the heart sounds decreased as MAC increased. Heart sounds were analyzed successfully with the esophageal stethoscope through the self-developed program and equipment. A proportional change in heart sounds was confirmed when blood pressure was changed using inotropics or volatile anesthetics. The esophageal stethoscope can achieve the closest proximity to the heart to hear sounds in a non-invasive manner.

  12. Pleiotropic Analysis of Lung Cancer and Blood Triglycerides

    NARCIS (Netherlands)

    Zuber, V.; Marconett, C.N.; Shi, J.; Hua, X.; Wheeler, W.; Yang, C.; Song, L; Dale, A.M.; Laplana, M.; Risch, A.; Witoelar, A.; Thompson, W.K.; Schork, A.J.; Bettella, F.; Wang, Y; Djurovic, S.; Zhou, B.; Borok, Z.; Heijden, H.F.M. van der; Graaf, J. de; Swinkels, D.W.; Aben, K.K.H.; McKay, J.; Hung, R.J.; Bikeboller, H.; Stevens, V.L.; Albanes, D.; Caporaso, N.E.; Han, Y.; Wei, Y.; Panadero, M.A.; Mayordomo, J.I.; Christiani, D.C.; Kiemeney, L.A.; Andreassen, O.A.; Houlston, R.; Amos, C.I.; Chatterjee, N.; Laird-Offringa, I.A.; Mills, I.G.; Landi, M.T.

    2016-01-01

    Epidemiologically related traits may share genetic risk factors, and pleiotropic analysis could identify individual loci associated with these traits. Because of their shared epidemiological associations, we conducted pleiotropic analysis of genome-wide association studies of lung cancer (12 160

  13. Path length entropy analysis of diastolic heart sounds.

    Science.gov (United States)

    Griffel, Benjamin; Zia, Mohammad K; Fridman, Vladamir; Saponieri, Cesare; Semmlow, John L

    2013-09-01

    Early detection of coronary artery disease (CAD) using the acoustic approach, a noninvasive and cost-effective method, would greatly improve the outcome of CAD patients. To detect CAD, we analyze diastolic sounds for possible CAD murmurs. We observed diastolic sounds to exhibit 1/f structure and developed a new method, path length entropy (PLE) and a scaled version (SPLE), to characterize this structure to improve CAD detection. We compare SPLE results to Hurst exponent, Sample entropy and Multiscale entropy for distinguishing between normal and CAD patients. SPLE achieved a sensitivity-specificity of 80%-81%, the best of the tested methods. However, PLE and SPLE are not sufficient to prove nonlinearity, and evaluation using surrogate data suggests that our cardiovascular sound recordings do not contain significant nonlinear properties. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Development of an Amplifier for Electronic Stethoscope System and Heart Sound Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. J.; Kang, D. K. [Chongju University, Chongju (Korea)

    2001-05-01

    The conventional stethoscope can not store its stethoscopic sounds. Therefore a doctor diagnoses a patient with instantaneous stethoscopic sounds at that time, and he can not remember the state of the patient's stethoscopic sounds on the next. This prevent accurate and objective diagnosis. If the electronic stethoscope, which can store the stethoscopic sound, is developed, the auscultation will be greatly improved. This study describes an amplifier for electronic stethoscope system that can extract heart sounds of fetus as well as adult and allow us hear and record the sounds. Using the developed stethoscopic amplifier, clean heart sounds of fetus and adult can be heard in noisy environment, such as a consultation room of a university hospital, a laboratory of a university. Surprisingly, the heart sound of a 22-week fetus was heard through the developed electronic stethoscope. Pitch detection experiments using the detected heart sounds showed that the signal represents distinct periodicity. It can be expected that the developed electronic stethoscope can substitute for conventional stethoscopes and if proper analysis method for the stethoscopic signal is developed, a good electronic stethoscope system can be produced. (author). 17 refs., 6 figs.

  15. Analysis of lung tissue particles among silicosis cases

    Directory of Open Access Journals (Sweden)

    B Case

    2005-10-01

    Full Text Available Background and Aims:Lung tissue samples of several miners, millers, sandblaster, welders andconstruction workers with historical exposure to mineral particles were analyzed. These subjectshad significant respiratory exposure to silica particles and demanded compensation foroccupational lung diseases.Method: Lung tissue samples were observed under an Electron microscope with 10000Xmagnification. Mineral particles were sized and analyzed by EDS detector based on X-rayspectrophotometry.Results: The results have indicated that the lung particle burden of the subjects was closelyrelated to their occupational history. The highest level of mineral silica particles were found in thelungs of miners and sandblasters. The highest concentration of metallic particles was found in thelungs of welders and miners in ferric mining industry. Severity of lung fibrosis was directlyrelated to the lung free silica concentration. However, no association was found between particlediameter and severity of fibrosis. In addition, lung particle burden of silicotic cases with lungcancer contained a much higher concentration of metallic particles and asbestos fibres that thelung of those subject with silicosis only.Conclusion: Although workers in mining and construction may be predominantly exposed tosilica particles including quartz, the role of other mineral particles including asbestos fibres,metallic fibres and other minerals should be taken into account in the genesis of occupational lungdisease in particular lung cancer. Lung tissue sample analysis can provide valuable informationto assess the legal and compensation cases.

  16. Water-Level Analysis for Cumberland Sound, Georgia

    National Research Council Canada - National Science Library

    Kraus, Nicholas

    1997-01-01

    .... The channel through St Marys Entrance is maintained at a 50-ft depth through significant dredging that occurred from 1986-1988 Questions arose as to whether this dredging had raised the water level in Cumberland Sound. The U.S...

  17. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope.

    Science.gov (United States)

    Ching, Siok Siong; Tan, Yih Kai

    2012-09-07

    To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann(®) Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen

  18. Auscultation of the lung: past lessons, future possibilities.

    Science.gov (United States)

    Murphy, R L

    1981-01-01

    Review of the history of auscultation of the lung reveals few scientific investigations. The majority of these have led to inconclusive results. The mechanism of production of normal breath sounds remains uncertain. Hypotheses for the generation of adventitious sounds are unproven. Advances in instrumentation for lung sound recording and analysis have provided little of clinical value. There has been a recent resurgence of interest in lung sounds. Space-age technology has improved methodology for sonic analysis significantly. Lung sounds are complex signals that probably reflect regional lung pathophysiology. If they were understood more clearly important non-invasive diagnostic tools could be devised and the value of clinical auscultation could be improved. A multidisciplinary effort will be required to achieve this. PMID:7268687

  19. Analysis of radiation fields in tomography on diffusion gaseous sound

    International Nuclear Information System (INIS)

    Bekman, I.N.

    1999-01-01

    Perspectives of application of equilibrium and stationary variants of diffusion tomography with radioactive gaseous sounds for spatial reconstruction of heterogeneous media in materials technology were considered. The basic attention were allocated to creation of simple algorithms of detection of sound accumulation on the background of monotonically varying concentration field. Algorithms of transformation of two-dimensional radiation field in three-dimensional distribution of radiation sources were suggested. The methods of analytical elongation of concentration field permitting separation of regional anomalies on the background of local ones and vice verse were discussed. It was shown that both equilibrium and stationary variants of diffusion tomography detect the heterogeneity of testing material, provide reduction of spatial distribution of elements of its structure and give an estimation of relative degree of defectiveness

  20. Applications of Hilbert Spectral Analysis for Speech and Sound Signals

    Science.gov (United States)

    Huang, Norden E.

    2003-01-01

    A new method for analyzing nonlinear and nonstationary data has been developed, and the natural applications are to speech and sound signals. The key part of the method is the Empirical Mode Decomposition method with which any complicated data set can be decomposed into a finite and often small number of Intrinsic Mode Functions (IMF). An IMF is defined as any function having the same numbers of zero-crossing and extrema, and also having symmetric envelopes defined by the local maxima and minima respectively. The IMF also admits well-behaved Hilbert transform. This decomposition method is adaptive, and, therefore, highly efficient. Since the decomposition is based on the local characteristic time scale of the data, it is applicable to nonlinear and nonstationary processes. With the Hilbert transform, the Intrinsic Mode Functions yield instantaneous frequencies as functions of time, which give sharp identifications of imbedded structures. This method invention can be used to process all acoustic signals. Specifically, it can process the speech signals for Speech synthesis, Speaker identification and verification, Speech recognition, and Sound signal enhancement and filtering. Additionally, as the acoustical signals from machinery are essentially the way the machines are talking to us. Therefore, the acoustical signals, from the machines, either from sound through air or vibration on the machines, can tell us the operating conditions of the machines. Thus, we can use the acoustic signal to diagnosis the problems of machines.

  1. Clinical analysis of 44 lung abscess cases

    International Nuclear Information System (INIS)

    Uruga, Hironori; Hanada, Shigeo; Takaya, Hisashi; Miyamoto, Atsushi; Morokawa, Nasa; Kishi, Kazuma

    2012-01-01

    Lung abscess is frequently caused by anaerobes that are difficult to diagnose by sputum examination. To evaluate diagnostic methods and bacteriology of lung abscesses, we retrospectively studied 44 consecutive lung abscess cases (37 men; 7 women; median age, 60 years) admitted and treated at our hospital from 2001 to 2010. The most frequent underlying disease was periodontitis (n=20, 45.5%). The diagnostic rate of causative pathogens by ultrasonography-guided fine-needle aspiration (n=2), computed tomography (CT)-guided fine-needle aspiration (n=19), sputum examination (n=37), and bronchoscopy (n=10) was 100, 68.4, 16.2, and 10%, respectively. In total, 43 causative pathogens were identified in 18 cases (40.9%), of which 12 (67%) had polymicrobial infections. Furthermore, anaerobes and bacterial species belonging to the Streptococcus anginosus group accounted for 55.8 and 14% of the 43 identified pathogens, and both were identified by examination of CT-guided fine-needle aspiration fluid in all cases, except for one patient. Every case was successfully treated with antibiotics. Anaerobes and species of the S. anginosus group are common causes of lung abscess, and CT-guided fine-needle aspiration is a useful diagnostic tool for identifying these causative agents. (author)

  2. Pleiotropic Analysis of Lung Cancer and Blood Triglycerides.

    Science.gov (United States)

    Zuber, Verena; Marconett, Crystal N; Shi, Jianxin; Hua, Xing; Wheeler, William; Yang, Chenchen; Song, Lei; Dale, Anders M; Laplana, Marina; Risch, Angela; Witoelar, Aree; Thompson, Wesley K; Schork, Andrew J; Bettella, Francesco; Wang, Yunpeng; Djurovic, Srdjan; Zhou, Beiyun; Borok, Zea; van der Heijden, Henricus F M; de Graaf, Jacqueline; Swinkels, Dorine; Aben, Katja K; McKay, James; Hung, Rayjean J; Bikeböller, Heike; Stevens, Victoria L; Albanes, Demetrius; Caporaso, Neil E; Han, Younghun; Wei, Yongyue; Panadero, Maria Angeles; Mayordomo, Jose I; Christiani, David C; Kiemeney, Lambertus; Andreassen, Ole A; Houlston, Richard; Amos, Christopher I; Chatterjee, Nilanjan; Laird-Offringa, Ite A; Mills, Ian G; Landi, Maria Teresa

    2016-12-01

    Epidemiologically related traits may share genetic risk factors, and pleiotropic analysis could identify individual loci associated with these traits. Because of their shared epidemiological associations, we conducted pleiotropic analysis of genome-wide association studies of lung cancer (12 160 lung cancer case patients and 16 838 control subjects) and cardiovascular disease risk factors (blood lipids from 188 577 subjects, type 2 diabetes from 148 821 subjects, body mass index from 123 865 subjects, and smoking phenotypes from 74 053 subjects). We found that 6p22.1 (rs6904596, ZNF184) was associated with both lung cancer (P = 5.50x10(-6)) and blood triglycerides (P = 1.39x10(-5)). We replicated the association in 6097 lung cancer case patients and 204 657 control subjects (P = 2.40 × 10(-4)) and in 71 113 subjects with triglycerides data (P = .01). rs6904596 reached genome-wide significance in lung cancer meta-analysis (odds ratio = 1.15, 95% confidence interval = 1.10 to 1.21 ,: Pcombined = 5.20x10(-9)). The large sample size provided by the lipid GWAS data and the shared genetic risk factors between the two traits contributed to the uncovering of a hitherto unidentified genetic locus for lung cancer. Published by Oxford University Press 2016. This work is written by US Government employees and is in the public domain in the United States.

  3. Acoustic analysis of swallowing sounds: a new technique for assessing dysphagia.

    Science.gov (United States)

    Santamato, Andrea; Panza, Francesco; Solfrizzi, Vincenzo; Russo, Anna; Frisardi, Vincenza; Megna, Marisa; Ranieri, Maurizio; Fiore, Pietro

    2009-07-01

    To perform acoustic analysis of swallowing sounds, using a microphone and a notebook computer system, in healthy subjects and patients with dysphagia affected by neurological diseases, testing the positive/negative predictive value of a pathological pattern of swallowing sounds for penetration/aspiration. Diagnostic test study, prospective, not blinded, with the penetration/aspiration evaluated by fibreoptic endoscopy of swallowing as criterion standard. Data from a previously recorded database of normal swallowing sounds for 60 healthy subjects according to gender, age, and bolus consistency was compared with those of 15 patients with dysphagia from a university hospital referral centre who were affected by various neurological diseases. Mean duration of the swallowing sounds and post-swallowing apnoea were recorded. Penetration/aspiration was verified by fibreoptic endoscopy of swallowing in all patients with dysphagia. The mean duration of swallowing sounds for a liquid bolus of 10 ml water was significantly different between patients with dysphagia and healthy patients. We also described patterns of swallowing sounds and tested the negative/positive predictive values of post-swallowing apnoea for penetration/aspiration verified by fibreoptic endoscopy of swallowing (sensitivity 0.67 (95% confidence interval 0.24-0.94); specificity 1.00 (95% confidence interval 0.56-1.00)). The proposed technique for recording and measuring swallowing sounds could be incorporated into the bedside evaluation, but it should not replace the use of more diagnostic and valuable measures.

  4. Analysis of speech sounds is left-hemisphere predominant at 100-150ms after sound onset.

    Science.gov (United States)

    Rinne, T; Alho, K; Alku, P; Holi, M; Sinkkonen, J; Virtanen, J; Bertrand, O; Näätänen, R

    1999-04-06

    Hemispheric specialization of human speech processing has been found in brain imaging studies using fMRI and PET. Due to the restricted time resolution, these methods cannot, however, determine the stage of auditory processing at which this specialization first emerges. We used a dense electrode array covering the whole scalp to record the mismatch negativity (MMN), an event-related brain potential (ERP) automatically elicited by occasional changes in sounds, which ranged from non-phonetic (tones) to phonetic (vowels). MMN can be used to probe auditory central processing on a millisecond scale with no attention-dependent task requirements. Our results indicate that speech processing occurs predominantly in the left hemisphere at the early, pre-attentive level of auditory analysis.

  5. X-ray analysis in lung leptospira disease

    International Nuclear Information System (INIS)

    Deng Shiyong; Peng Shi; He Guoman

    2006-01-01

    Objective: To analysis the X-ray signs and subtype of the lung leptospira disease, and improve the undersdand, reduce the error diagnosis of this diseases. Methods: 40 cases of lung leptospira disease were evaluated about the check X-ray sings and clinical data, the check X-ray sings were dynamic observated and typed, and 40 cases had a diagnostic treatment. Results: There were various X-ray changes of lung leptospira disease. in 40 cases, 12 cases (30%) pulmonary marking, 21 cases (52%) little lesions, and 7 cases(18%) lager lesions, respectively. The patients who were correctly diagnosed made a recovery after effective treatment, the patients who were error diagnosed died because of multiple system organ damage. Conclusion: The check X-ray signs in lung leptospira disease have some characteristics. It may play an important role in improving this disease' diagnosis combining the dynamic observation of check X-ray sings with clinical data. (authors)

  6. Frictional Sound Analysis by Simulating the Human Arm Movement

    Directory of Open Access Journals (Sweden)

    Yosouf Khaldon

    2017-03-01

    Full Text Available Fabric noise generated by fabric-to-fabric friction is considered as one of the auditory disturbances that can have an impact on the quality of some textile products. For this reason, an instrument has been developed to analyse this phenomenon. The instrument is designed to simulate the relative movement of a human arm when walking. In order to understand the nature of the relative motion of a human arm, films of the upper half of the human body were taken. These films help to define the parameters required for movement simulation. These parameters are movement trajectory, movement velocity, arm pressure applied on the lateral part of the trunk and the friction area. After creating the instrument, a set of soundtracks related to the noise generated by fabric-to-fabric friction was recorded. The recordings were treated with a specific software to extract the sound parameters and the acoustic imprints of fabric were obtained.

  7. meta-analysis of Serum Tumor Markers in Lung Cancer

    Directory of Open Access Journals (Sweden)

    Xianfeng LU

    2010-12-01

    Full Text Available Background and objective The detection of serum tumor markers is of great value for early diagnosis of lung cancer. The aim of this study is to summarize the clinic significance characteristics of serum markers contributing to the detection of lung cancer. Methods References about serum markers of lung cancer were estimated using meta-analysis method. 712 references which included more than 20 cases, 20 controls, the serum markers of 52 832 patients with malignancies and 32 037 patients as controls were evaluated. Results Overall the detection of 13 markers play a significant part in lung cancer diagnosis. The sensitivity of CEA, CA125, CYFRA21-1, TPA, SCCAg, DKK1, NSE, ProGRP in the patients’ serum with lung cancer were 47.50%, 50.11%, 57.00%, 50.93%, 49.00%, 69.50%, 39.73%, 51.48% and the specificity were 92.34%, 80.19%, 90.16%, 88.41%, 91.07%, 92.20%, 89.11%, 94.89%. In the combined analysis of tumor markers: the sensitivity, specificity of NSE+ProGRP were 88.90% and 72.82% in diagnosis of small cell lung cancer, respectively. In diagnosis of squamous corcinoma, the sensitivity and specificity of TSGF+SCCAg+CYFRA21-1 were 95.30% and 74.20%. The the sensitivity and specificity of CA153+Ferrtin+CEA were 91.90% and 44.00% in diagnosis of lung cancer. Conclusion Although the assay of tumor markers in serum is useful for diagnosis of early lung cancer, the sensitivity and specificity are low. Combined detection of these tumor markers could increase sensitivity and specificity.

  8. Selenium and Lung Cancer: A Systematic Review and Meta Analysis

    Science.gov (United States)

    Fritz, Heidi; Kennedy, Deborah; Fergusson, Dean; Fernandes, Rochelle; Cooley, Kieran; Seely, Andrew; Sagar, Stephen; Wong, Raimond; Seely, Dugald

    2011-01-01

    Background Selenium is a natural health product widely used in the treatment and prevention of lung cancers, but large chemoprevention trials have yielded conflicting results. We conducted a systematic review of selenium for lung cancers, and assessed potential interactions with conventional therapies. Methods and Findings Two independent reviewers searched six databases from inception to March 2009 for evidence pertaining to the safety and efficacy of selenium for lung cancers. Pubmed and EMBASE were searched to October 2009 for evidence on interactions with chemo- or radiation-therapy. In the efficacy analysis there were nine reports of five RCTs and two biomarker-based studies, 29 reports of 26 observational studies, and 41 preclinical studies. Fifteen human studies, one case report, and 36 preclinical studies were included in the interactions analysis. Based on available evidence, there appears to be a different chemopreventive effect dependent on baseline selenium status, such that selenium supplementation may reduce risk of lung cancers in populations with lower baseline selenium status (serumselenium (≥121.6 ng/mL). Pooling data from two trials yielded no impact to odds of lung cancer, OR 0.93 (95% confidence interval 0.61–1.43); other cancers that were the primary endpoints of these trials, OR 1.51 (95%CI 0.70–3.24); and all-cause-death, OR 0.93 (95%CI 0.79–1.10). In the treatment of lung cancers, selenium may reduce cisplatin-induced nephrotoxicity and side effects associated with radiation therapy. Conclusions Selenium may be effective for lung cancer prevention among individuals with lower selenium status, but at present should not be used as a general strategy for lung cancer prevention. Although promising, more evidence on the ability of selenium to reduce cisplatin and radiation therapy toxicity is required to ensure that therapeutic efficacy is maintained before any broad clinical recommendations can be made in this context. PMID:22073154

  9. Exploring science with sound: sonification and the use of sonograms as data analysis tool

    CERN Multimedia

    CERN. Geneva; Williams, Genevieve

    2017-01-01

    Resonances, periodicity, patterns and spectra are well-known notions that play crucial roles in particle physics, and that have always been at the junction between sound/music analysis and scientific exploration. Detecting the shape of a particular energy spectrum, studying the stability of a particle beam in a synchrotron, and separating signals from a noisy background are just a few examples where the connection with sound can be very strong, all sharing the same concepts of oscillations, cycles and frequency. This seminar will focus on analysing data and their relations by translating measurements into audible signals and using the natural capability of the ear to distinguish, characterise and analyse waveform shapes, amplitudes and relations. This process is called data sonification, and one of the main tools to investigate the structure of the sound is the sonogram (sometimes also called a spectrogram). A sonogram is a visual representation of how the spectrum of a certain sound signal changes with time...

  10. An Exploratory Analysis of Sound Field Characteristics using the Impulse Response in a Car Cabin

    Directory of Open Access Journals (Sweden)

    Yoshiharu Soeta

    2018-03-01

    Full Text Available Sound environments in cars are becoming quieter and receiving attention because of the prevalence of low-noise engines such as hybrid and electric engines and the manifestation of automated driving. Although the car cabin has potential as a listening space, its acoustic quality has not been examined in detail. The present study investigated sound field characteristics in the car cabin using acoustic parameters obtained by impulse response analysis. In particular, effects of the passenger position, open windows and the use of an air conditioner on acoustic parameters were investigated. The passenger position affected the sound strength at low frequencies. Rear seats, except for the rear central seat, had lower interaural correlation than the front seats, suggesting that rear seats have more diffused sound fields. The opening of windows and use of air conditioners attenuated the ratio of early- and late-arriving energy at high frequencies, suggesting a loss of clarity for music.

  11. Analysis of sound data streamed over the network

    Directory of Open Access Journals (Sweden)

    Jiří Fejfar

    2013-01-01

    Full Text Available In this paper we inspect a difference between original sound recording and signal captured after streaming this original recording over a network loaded with a heavy traffic. There are several kinds of failures occurring in the captured recording caused by network congestion. We try to find a method how to evaluate correctness of streamed audio. Usually there are metrics based on a human perception of a signal such as “signal is clear, without audible failures”, “signal is having some failures but it is understandable”, or “signal is inarticulate”. These approaches need to be statistically evaluated on a broad set of respondents, which is time and resource consuming. We try to propose some metrics based on signal properties allowing us to compare the original and captured recording. We use algorithm called Dynamic Time Warping (Müller, 2007 commonly used for time series comparison in this paper. Some other time series exploration approaches can be found in (Fejfar, 2011 and (Fejfar, 2012. The data was acquired in our network laboratory simulating network traffic by downloading files, streaming audio and video simultaneously. Our former experiment inspected Quality of Service (QoS and its impact on failures of received audio data stream. This experiment is focused on the comparison of sound recordings rather than network mechanism.We focus, in this paper, on a real time audio stream such as a telephone call, where it is not possible to stream audio in advance to a “pool”. Instead it is necessary to achieve as small delay as possible (between speaker voice recording and listener voice replay. We are using RTP protocol for streaming audio.

  12. Analysis of lung tissue using ion beams

    International Nuclear Information System (INIS)

    Alvarez, J.L.; Barrera, R.; Miranda, J.

    2002-01-01

    In this work a comparative study is presented of the contents of metals in lung tissue from healthy patients and with lung cancer, by means of two analytical techniques: Particle Induced X-ray Emission (PIXE) and Rutherford Backscattering Spectrometry (RBS). The samples of cancerous tissue were taken from 26 autopsies made to individuals died in the National Institute of Respiratory Disease (INER), 22 of cancer and 4 of other non-cancer biopsies. When analyzing the entirety of the samples, in the cancerous tissues, there were increments in the concentrations of S (4%), K (635%), Co (85%) and Cu (13%). Likewise, there were deficiencies in the concentrations of Cl (59%), Ca (6%), Fe (26%) and Zn (7%). Only in the cancerous tissues there were appearances of P, Ca, Ti, V, Cr, Mn, Ni, Br and Sr. The tissue samples were classified according to cancer types (adenocarcinomas, epidermoides and of small cell carcinoma), personal habits (smokers and alcoholic), genetic predisposition and residence place. There was a remarkable decrease in the concentration of Ca and a marked increment in the Cu in the epidermoide tissue samples with regard to those of adenocarcinoma or of small cells cancer. Also, decrements were detected in K and increments of Fe, Co and Cu in the sample belonging to people that resided in Mexico City with regard to those that resided in the State of Mexico

  13. Automatic system for quantification and visualization of lung aeration on chest computed tomography images: the Lung Image System Analysis - LISA

    Energy Technology Data Exchange (ETDEWEB)

    Felix, John Hebert da Silva; Cortez, Paulo Cesar, E-mail: jhsfelix@gmail.co [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Dept. de Engenharia de Teleinformatica; Holanda, Marcelo Alcantara [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Hospital Universitario Walter Cantidio. Dept. de Medicina Clinica

    2010-12-15

    High Resolution Computed Tomography (HRCT) is the exam of choice for the diagnostic evaluation of lung parenchyma diseases. There is an increasing interest for computational systems able to automatically analyze the radiological densities of the lungs in CT images. The main objective of this study is to present a system for the automatic quantification and visualization of the lung aeration in HRCT images of different degrees of aeration, called Lung Image System Analysis (LISA). The secondary objective is to compare LISA to the Osiris system and also to specific algorithm lung segmentation (ALS), on the accuracy of the lungs segmentation. The LISA system automatically extracts the following image attributes: lungs perimeter, cross sectional area, volume, the radiological densities histograms, the mean lung density (MLD) in Hounsfield units (HU), the relative area of the lungs with voxels with density values lower than -950 HU (RA950) and the 15th percentile of the least density voxels (PERC15). Furthermore, LISA has a colored mask algorithm that applies pseudo-colors to the lung parenchyma according to the pre-defined radiological density chosen by the system user. The lungs segmentations of 102 images of 8 healthy volunteers and 141 images of 11 patients with Chronic Obstructive Pulmonary Disease (COPD) were compared on the accuracy and concordance among the three methods. The LISA was more effective on lungs segmentation than the other two methods. LISA's color mask tool improves the spatial visualization of the degrees of lung aeration and the various attributes of the image that can be extracted may help physicians and researchers to better assess lung aeration both quantitatively and qualitatively. LISA may have important clinical and research applications on the assessment of global and regional lung aeration and therefore deserves further developments and validation studies. (author)

  14. Automatic system for quantification and visualization of lung aeration on chest computed tomography images: the Lung Image System Analysis - LISA

    International Nuclear Information System (INIS)

    Felix, John Hebert da Silva; Cortez, Paulo Cesar; Holanda, Marcelo Alcantara

    2010-01-01

    High Resolution Computed Tomography (HRCT) is the exam of choice for the diagnostic evaluation of lung parenchyma diseases. There is an increasing interest for computational systems able to automatically analyze the radiological densities of the lungs in CT images. The main objective of this study is to present a system for the automatic quantification and visualization of the lung aeration in HRCT images of different degrees of aeration, called Lung Image System Analysis (LISA). The secondary objective is to compare LISA to the Osiris system and also to specific algorithm lung segmentation (ALS), on the accuracy of the lungs segmentation. The LISA system automatically extracts the following image attributes: lungs perimeter, cross sectional area, volume, the radiological densities histograms, the mean lung density (MLD) in Hounsfield units (HU), the relative area of the lungs with voxels with density values lower than -950 HU (RA950) and the 15th percentile of the least density voxels (PERC15). Furthermore, LISA has a colored mask algorithm that applies pseudo-colors to the lung parenchyma according to the pre-defined radiological density chosen by the system user. The lungs segmentations of 102 images of 8 healthy volunteers and 141 images of 11 patients with Chronic Obstructive Pulmonary Disease (COPD) were compared on the accuracy and concordance among the three methods. The LISA was more effective on lungs segmentation than the other two methods. LISA's color mask tool improves the spatial visualization of the degrees of lung aeration and the various attributes of the image that can be extracted may help physicians and researchers to better assess lung aeration both quantitatively and qualitatively. LISA may have important clinical and research applications on the assessment of global and regional lung aeration and therefore deserves further developments and validation studies. (author)

  15. Integrated quantitative fractal polarimetric analysis of monolayer lung cancer cells

    Science.gov (United States)

    Shrestha, Suman; Zhang, Lin; Quang, Tri; Farrahi, Tannaz; Narayan, Chaya; Deshpande, Aditi; Na, Ying; Blinzler, Adam; Ma, Junyu; Liu, Bo; Giakos, George C.

    2014-05-01

    Digital diagnostic pathology has become one of the most valuable and convenient advancements in technology over the past years. It allows us to acquire, store and analyze pathological information from the images of histological and immunohistochemical glass slides which are scanned to create digital slides. In this study, efficient fractal, wavelet-based polarimetric techniques for histological analysis of monolayer lung cancer cells will be introduced and different monolayer cancer lines will be studied. The outcome of this study indicates that application of fractal, wavelet polarimetric principles towards the analysis of squamous carcinoma and adenocarcinoma cancer cell lines may be proved extremely useful in discriminating among healthy and lung cancer cells as well as differentiating among different lung cancer cells.

  16. Sound and sound sources

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Wahlberg, Magnus

    2017-01-01

    There is no difference in principle between the infrasonic and ultrasonic sounds, which are inaudible to humans (or other animals) and the sounds that we can hear. In all cases, sound is a wave of pressure and particle oscillations propagating through an elastic medium, such as air. This chapter...... is about the physical laws that govern how animals produce sound signals and how physical principles determine the signals’ frequency content and sound level, the nature of the sound field (sound pressure versus particle vibrations) as well as directional properties of the emitted signal. Many...... of these properties are dictated by simple physical relationships between the size of the sound emitter and the wavelength of emitted sound. The wavelengths of the signals need to be sufficiently short in relation to the size of the emitter to allow for the efficient production of propagating sound pressure waves...

  17. Analysis of diffuse gallium lung uptake

    International Nuclear Information System (INIS)

    Harada, Masahumi; Sui, Osamu; Mukaijo, Toshihumi; Tokuyama, Noritami; Tanouchi, Miki; Kitsukawa, Kaoru

    1989-01-01

    Diffuse lung uptake of Ga-67 was observed on scintigrams in 56 patients. It was considered attributable to drugs in 21 patients. Only 7 patients complained of fever, cough, and dyspnea, 5 of whom spontaneously recovered without any treatment. This seemed to reflect clinically reversible cases, as well as to support the usefulness of Ga-67 scintigraphy in early detection of drug-induced pneumonitis. In one patient that died of acute pneumonitis, only a small amount of cyclophosphamide (3,400 mg) had been administered. Drug dosage seemed to be unrelated to the prognosis of drug-induced pneumonitis. Seventeen patients underwent Ga-67 scintigraphy within one month after the completion of chemotherapy. The most frequently given dosage of cyclophosphamide was 2,000 mg or less. In early detecting drug-induced pneumonitis, the optimum time of Ga-67 scintigraphy was considered to be the first one month after completion of chemotherapy. (Namekawa, K)

  18. Respiratory lung motion analysis using a nonlinear motion correction technique for respiratory-gated lung perfusion SPECT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Haneishi, Hideaki; Iwanaga, Hideyuki; Suga, Kazuyoshi

    2007-01-01

    This study evaluated the respiratory motion of lungs using a nonlinear motion correction technique for respiratory-gated single photon emission computed tomography (SPECT) images. The motion correction technique corrects the respiratory motion of the lungs nonlinearly between two-phase images obtained by respiratory-gated SPECT. The displacement vectors resulting from respiration can be computed at every location of the lungs. Respiratory lung motion analysis is carried out by calculating the mean value of the body axis component of the displacement vector in each of the 12 small regions into which the lungs were divided. In order to enable inter-patient comparison, the 12 mean values were normalized by the length of the lung region along the direction of the body axis. This method was applied to 25 Technetium (Tc)-99m-macroaggregated albumin (MAA) perfusion SPECT images, and motion analysis results were compared with the diagnostic results. It was confirmed that the respiratory lung motion reflects the ventilation function. A statistically significant difference in the amount of the respiratory lung motion was observed between the obstructive pulmonary diseases and other conditions, based on an unpaired Student's t test (P<0.0001). A difference in the motion between normal lungs and lungs with a ventilation obstruction was detected by the proposed method. This method is effective for evaluating obstructive pulmonary diseases such as pulmonary emphysema and diffuse panbronchiolitis. (author)

  19. The impact of the microphone position on the frequency analysis of snoring sounds.

    Science.gov (United States)

    Herzog, Michael; Kühnel, Thomas; Bremert, Thomas; Herzog, Beatrice; Hosemann, Werner; Kaftan, Holger

    2009-08-01

    Frequency analysis of snoring sounds has been reported as a diagnostic tool to differentiate between different sources of snoring. Several studies have been published presenting diverging results of the frequency analyses of snoring sounds. Depending on the position of the used microphones, the results of the frequency analysis of snoring sounds vary. The present study investigated the influence of different microphone positions on the outcome of the frequency analysis of snoring sounds. Nocturnal snoring was recorded simultaneously at six positions (air-coupled: 30 cm middle, 100 cm middle, 30 cm lateral to both sides of the patients' head; body contact: neck and parasternal) in five patients. The used microphones had a flat frequency response and a similar frequency range (10/40 Hz-18 kHz). Frequency analysis was performed by fast Fourier transformation and frequency bands as well as peak intensities (Peaks 1-5) were detected. Air-coupled microphones presented a wider frequency range (60 Hz-10 kHz) compared to contact microphones. The contact microphone at cervical position presented a cut off at frequencies above 300 Hz, whereas the contact microphone at parasternal position revealed a cut off above 100 Hz. On an exemplary base, the study demonstrates that frequencies above 1,000 Hz do appear in complex snoring patterns, and it is emphasised that high frequencies are imported for the interpretation of snoring sounds with respect to the identification of the source of snoring. Contact microphones might be used in screening devices, but for a natural analysis of snoring sounds the use of air-coupled microphones is indispensable.

  20. Differences in chewing sounds of dry-crisp snacks by multivariate data analysis

    Science.gov (United States)

    De Belie, N.; Sivertsvik, M.; De Baerdemaeker, J.

    2003-09-01

    Chewing sounds of different types of dry-crisp snacks (two types of potato chips, prawn crackers, cornflakes and low calorie snacks from extruded starch) were analysed to assess differences in sound emission patterns. The emitted sounds were recorded by a microphone placed over the ear canal. The first bite and the first subsequent chew were selected from the time signal and a fast Fourier transformation provided the power spectra. Different multivariate analysis techniques were used for classification of the snack groups. This included principal component analysis (PCA) and unfold partial least-squares (PLS) algorithms, as well as multi-way techniques such as three-way PLS, three-way PCA (Tucker3), and parallel factor analysis (PARAFAC) on the first bite and subsequent chew. The models were evaluated by calculating the classification errors and the root mean square error of prediction (RMSEP) for independent validation sets. It appeared that the logarithm of the power spectra obtained from the chewing sounds could be used successfully to distinguish the different snack groups. When different chewers were used, recalibration of the models was necessary. Multi-way models distinguished better between chewing sounds of different snack groups than PCA on bite or chew separately and than unfold PLS. From all three-way models applied, N-PLS with three components showed the best classification capabilities, resulting in classification errors of 14-18%. The major amount of incorrect classifications was due to one type of potato chips that had a very irregular shape, resulting in a wide variation of the emitted sounds.

  1. Data Analysis of the TK-1G Sounding Rocket Installed with a Satellite Navigation System

    Directory of Open Access Journals (Sweden)

    Lesong Zhou

    2017-10-01

    Full Text Available This article gives an in-depth analysis of the experimental data of the TK-1G sounding rocket installed with the satellite navigation system. It turns out that the data acquisition rate of the rocket sonde is high, making the collection of complete trajectory and meteorological data possible. By comparing the rocket sonde measurements with those obtained by virtue of other methods, we find that the rocket sonde can be relatively precise in measuring atmospheric parameters within the scope of 20–60 km above the ground. This establishes the fact that the TK-1G sounding rocket system is effective in detecting near-space atmospheric environment.

  2. Speed of sound reflects Young's modulus as assessed by microstructural finite element analysis

    NARCIS (Netherlands)

    Bergh, van den J.P.W.; Lenthe, van G.H.; Hermus, A.R.M.M.; Corstens, F.H.M.; Smals, A.G.H.; Huiskes, H.W.J.

    2000-01-01

    We analyzed the ability of the quantitative ultrasound (QUS) parameter, speed of sound (SOS), and bone mineral density (BMD), as measured by dual-energy X-ray absorptiometry (DXA), to predict Young's modulus, as assessed by microstructural finite element analysis (muFEA) from microcomputed

  3. Isogeometric analysis of sound propagation through laminar flow in 2-dimensional ducts

    DEFF Research Database (Denmark)

    Nørtoft, Peter; Gravesen, Jens; Willatzen, Morten

    2015-01-01

    We consider the propagation of sound through a slowly moving fluid in a 2-dimensional duct. A detailed description of a flow-acoustic model of the problem using B-spline based isogeometric analysis is given. The model couples the non-linear, steady-state, incompressible Navier-Stokes equation in ...

  4. Acoustic analysis of snoring sounds recorded with a smartphone according to obstruction site in OSAS patients.

    Science.gov (United States)

    Koo, Soo Kweon; Kwon, Soon Bok; Kim, Yang Jae; Moon, J I Seung; Kim, Young Jun; Jung, Sung Hoon

    2017-03-01

    Snoring is a sign of increased upper airway resistance and is the most common symptom suggestive of obstructive sleep apnea. Acoustic analysis of snoring sounds is a non-invasive diagnostic technique and may provide a screening test that can determine the location of obstruction sites. We recorded snoring sounds according to obstruction level, measured by DISE, using a smartphone and focused on the analysis of formant frequencies. The study group comprised 32 male patients (mean age 42.9 years). The spectrogram pattern, intensity (dB), fundamental frequencies (F 0 ), and formant frequencies (F 1 , F 2 , and F 3 ) of the snoring sounds were analyzed for each subject. On spectrographic analysis, retropalatal level obstruction tended to produce sharp and regular peaks, while retrolingual level obstruction tended to show peaks with a gradual onset and decay. On formant frequency analysis, F 1 (retropalatal level vs. retrolingual level: 488.1 ± 125.8 vs. 634.7 ± 196.6 Hz) and F 2 (retropalatal level vs. retrolingual level: 1267.3 ± 306.6 vs. 1723.7 ± 550.0 Hz) of retrolingual level obstructions showed significantly higher values than retropalatal level obstruction (p smartphone can be effective for recording snoring sounds.

  5. A review of intelligent systems for heart sound signal analysis.

    Science.gov (United States)

    Nabih-Ali, Mohammed; El-Dahshan, El-Sayed A; Yahia, Ashraf S

    2017-10-01

    Intelligent computer-aided diagnosis (CAD) systems can enhance the diagnostic capabilities of physicians and reduce the time required for accurate diagnosis. CAD systems could provide physicians with a suggestion about the diagnostic of heart diseases. The objective of this paper is to review the recent published preprocessing, feature extraction and classification techniques and their state of the art of phonocardiogram (PCG) signal analysis. Published literature reviewed in this paper shows the potential of machine learning techniques as a design tool in PCG CAD systems and reveals that the CAD systems for PCG signal analysis are still an open problem. Related studies are compared to their datasets, feature extraction techniques and the classifiers they used. Current achievements and limitations in developing CAD systems for PCG signal analysis using machine learning techniques are presented and discussed. In the light of this review, a number of future research directions for PCG signal analysis are provided.

  6. Analysis and Optimal Condition of the Rear-Sound-Aided Control Source in Active Noise Control

    Directory of Open Access Journals (Sweden)

    Karel Kreuter

    2011-01-01

    Full Text Available An active noise control scenario of simple ducts is considered. The previously suggested technique of using an single loudspeaker and its rear sound to cancel the upstream sound is further examined and compared to the bidirectional solution in order to give theoretical proof of its advantage. Firstly, a model with a new approach for taking damping effects into account is derived based on the electrical transmission line theory. By comparison with the old model, the new approach is validated, and occurring differences are discussed. Moreover, a numerical application with the consideration of damping is implemented for confirmation. The influence of the rear sound strength on the feedback-path system is investigated, and the optimal condition is determined. Finally, it is proven that the proposed source has an advantage of an extended phase lag and a time delay in the feedback-path system by both frequency-response analysis and numerical calculation of the time response.

  7. An analysis of collegiate band directors' exposure to sound pressure levels

    Science.gov (United States)

    Roebuck, Nikole Moore

    Noise-induced hearing loss (NIHL) is a significant but unfortunate common occupational hazard. The purpose of the current study was to measure the magnitude of sound pressure levels generated within a collegiate band room and determine if those sound pressure levels are of a magnitude that exceeds the policy standards and recommendations of the Occupational Safety and Health Administration (OSHA), and the National Institute of Occupational Safety and Health (NIOSH). In addition, reverberation times were measured and analyzed in order to determine the appropriateness of acoustical conditions for the band rehearsal environment. Sound pressure measurements were taken from the rehearsal of seven collegiate marching bands. Single sample t test were conducted to compare the sound pressure levels of all bands to the noise exposure standards of OSHA and NIOSH. Multiple regression analysis were conducted and analyzed in order to determine the effect of the band room's conditions on the sound pressure levels and reverberation times. Time weighted averages (TWA), noise percentage doses, and peak levels were also collected. The mean Leq for all band directors was 90.5 dBA. The total accumulated noise percentage dose for all band directors was 77.6% of the maximum allowable daily noise dose under the OSHA standard. The total calculated TWA for all band directors was 88.2% of the maximum allowable daily noise dose under the OSHA standard. The total accumulated noise percentage dose for all band directors was 152.1% of the maximum allowable daily noise dose under the NIOSH standards, and the total calculated TWA for all band directors was 93dBA of the maximum allowable daily noise dose under the NIOSH standard. Multiple regression analysis revealed that the room volume, the level of acoustical treatment and the mean room reverberation time predicted 80% of the variance in sound pressure levels in this study.

  8. Multidisciplinary Analysis and Optimal Design: As Easy as it Sounds?

    Science.gov (United States)

    Moore, Greg; Chainyk, Mike; Schiermeier, John

    2004-01-01

    The viewgraph presentation examines optimal design for precision, large aperture structures. Discussion focuses on aspects of design optimization, code architecture and current capabilities, and planned activities and collaborative area suggestions. The discussion of design optimization examines design sensitivity analysis; practical considerations; and new analytical environments including finite element-based capability for high-fidelity multidisciplinary analysis, design sensitivity, and optimization. The discussion of code architecture and current capabilities includes basic thermal and structural elements, nonlinear heat transfer solutions and process, and optical modes generation.

  9. Full-Band Quasi-Harmonic Analysis and Synthesis of Musical Instrument Sounds with Adaptive Sinusoids

    Directory of Open Access Journals (Sweden)

    Marcelo Caetano

    2016-05-01

    Full Text Available Sinusoids are widely used to represent the oscillatory modes of musical instrument sounds in both analysis and synthesis. However, musical instrument sounds feature transients and instrumental noise that are poorly modeled with quasi-stationary sinusoids, requiring spectral decomposition and further dedicated modeling. In this work, we propose a full-band representation that fits sinusoids across the entire spectrum. We use the extended adaptive Quasi-Harmonic Model (eaQHM to iteratively estimate amplitude- and frequency-modulated (AM–FM sinusoids able to capture challenging features such as sharp attacks, transients, and instrumental noise. We use the signal-to-reconstruction-error ratio (SRER as the objective measure for the analysis and synthesis of 89 musical instrument sounds from different instrumental families. We compare against quasi-stationary sinusoids and exponentially damped sinusoids. First, we show that the SRER increases with adaptation in eaQHM. Then, we show that full-band modeling with eaQHM captures partials at the higher frequency end of the spectrum that are neglected by spectral decomposition. Finally, we demonstrate that a frame size equal to three periods of the fundamental frequency results in the highest SRER with AM–FM sinusoids from eaQHM. A listening test confirmed that the musical instrument sounds resynthesized from full-band analysis with eaQHM are virtually perceptually indistinguishable from the original recordings.

  10. Sweet Spot Size in Virtual Sound Reproduction: A Temporal Analysis

    DEFF Research Database (Denmark)

    Lacouture Parodi, Yesenia; Rubak, Per

    2009-01-01

    The influence of head misalignments on the performance of binaural reproduction systems through loudspeakers is often evaluated in the frequency domain. The changes in magnitude give us an idea of how much of the crosstalk is leaked into the direct signal and therefore a sweet spot performance can......-correlation we estimate the interaural time delay and define a sweet spot. The analysis is based on measurements carried out on 21 different loudspeaker configurations, including two- and four-channels arrangements. Results show that closely spaced loudspeakers are more robust to lateral displacements than wider...... span angles. Additionally, the sweet spot as a function of head rotations increases systematically when the loudspeakers are placed at elevated positions....

  11. The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs

    Science.gov (United States)

    Capuano, Rosamaria; Santonico, Marco; Pennazza, Giorgio; Ghezzi, Silvia; Martinelli, Eugenio; Roscioni, Claudio; Lucantoni, Gabriele; Galluccio, Giovanni; Paolesse, Roberto; di Natale, Corrado; D'Amico, Arnaldo

    2015-11-01

    Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath.

  12. Histological analysis of trachea and lung of newborn dogs

    Directory of Open Access Journals (Sweden)

    Andrezza Braga Soares da Silva

    2016-11-01

    Full Text Available The neonatology science is, in Veterinary Medicine, studying the post-birth to the development of certain characteristics of resistance, which for canines occurs until the second week of life. The newborn requires a precise approach given the particularities of their physiology and immunology extremely immature. The histological study elucidates problems morphological and functional abnormalities, as it provides a reliable and microscopic analysis. Aimed to analyze trachea and lung of newborn dogs through techniques of basic histology. We used five neonates that died postpartum. These were weighed, measured and dissected. Proceeded to the extraction of the trachea, bronchus and lung for submitting these samples to histological routine. The tracheal tissue presents a pseudostratified columnar ciliated epithelium with globet cells, a small amount of glands in the lamina propria and hyaline cartilage not fully developed. As regards the bronchial tissue may be observed well defined layers, pulmonary pseudostratified columnar ciliated epithelium with goblet cells in the lamina propria several bundles of smooth muscle and thick vascularized tissue. Likewise, the signs of bronchial cartilage present under development. The bronchioles also feature the common pulmonary epithelium and lamina propria also normal pens without smooth muscle. The bags alveolar lung cells showed typical. The lung tissues of newborn dogs present is still in development stage. It is possible to understand patterns of histogenesis and morphogenesis in newborn dogs.

  13. A multivariate analysis of serum nutrient levels and lung function

    Directory of Open Access Journals (Sweden)

    Smit Henriette A

    2008-09-01

    Full Text Available Abstract Background There is mounting evidence that estimates of intakes of a range of dietary nutrients are related to both lung function level and rate of decline, but far less evidence on the relation between lung function and objective measures of serum levels of individual nutrients. The aim of this study was to conduct a comprehensive examination of the independent associations of a wide range of serum markers of nutritional status with lung function, measured as the one-second forced expiratory volume (FEV1. Methods Using data from the Third National Health and Nutrition Examination Survey, a US population-based cross-sectional study, we investigated the relation between 21 serum markers of potentially relevant nutrients and FEV1, with adjustment for potential confounding factors. Systematic approaches were used to guide the analysis. Results In a mutually adjusted model, higher serum levels of antioxidant vitamins (vitamin A, beta-cryptoxanthin, vitamin C, vitamin E, selenium, normalized calcium, chloride, and iron were independently associated with higher levels of FEV1. Higher concentrations of potassium and sodium were associated with lower FEV1. Conclusion Maintaining higher serum concentrations of dietary antioxidant vitamins and selenium is potentially beneficial to lung health. In addition other novel associations found in this study merit further investigation.

  14. Variation of the Korotkoff Stethoscope Sounds During Blood Pressure Measurement: Analysis Using a Convolutional Neural Network.

    Science.gov (United States)

    Pan, Fan; He, Peiyu; Liu, Chengyu; Li, Taiyong; Murray, Alan; Zheng, Dingchang

    2017-11-01

    Korotkoff sounds are known to change their characteristics during blood pressure (BP) measurement, resulting in some uncertainties for systolic and diastolic pressure (SBP and DBP) determinations. The aim of this study was to assess the variation of Korotkoff sounds during BP measurement by examining all stethoscope sounds associated with each heartbeat from above systole to below diastole during linear cuff deflation. Three repeat BP measurements were taken from 140 healthy subjects (age 21 to 73 years; 62 female and 78 male) by a trained observer, giving 420 measurements. During the BP measurements, the cuff pressure and stethoscope signals were simultaneously recorded digitally to a computer for subsequent analysis. Heartbeats were identified from the oscillometric cuff pressure pulses. The presence of each beat was used to create a time window (1 s, 2000 samples) centered on the oscillometric pulse peak for extracting beat-by-beat stethoscope sounds. A time-frequency two-dimensional matrix was obtained for the stethoscope sounds associated with each beat, and all beats between the manually determined SBPs and DBPs were labeled as "Korotkoff." A convolutional neural network was then used to analyze consistency in sound patterns that were associated with Korotkoff sounds. A 10-fold cross-validation strategy was applied to the stethoscope sounds from all 140 subjects, with the data from ten groups of 14 subjects being analyzed separately, allowing consistency to be evaluated between groups. Next, within-subject variation of the Korotkoff sounds analyzed from the three repeats was quantified, separately for each stethoscope sound beat. There was consistency between folds with no significant differences between groups of 14 subjects (P = 0.09 to P = 0.62). Our results showed that 80.7% beats at SBP and 69.5% at DBP were analyzed as Korotkoff sounds, with significant differences between adjacent beats at systole (13.1%, P = 0.001) and diastole (17.4%, P < 0

  15. High frequency analysis of cough sounds in pediatric patients with respiratory diseases.

    Science.gov (United States)

    Kosasih, K; Abeyratne, U R; Swarnkar, V

    2012-01-01

    Cough is a common symptom in a range of respiratory diseases and is considered a natural defense mechanism of the body. Despite its critical importance in the diagnosis of illness, there are no golden methods to objectively assess cough. In a typical consultation session, a physician may briefly listen to the cough sounds using a stethoscope placed against the chest. The physician may also listen to spontaneous cough sounds via naked ears, as they naturally propagate through air. Cough sounds carry vital information on the state of the respiratory system but the field of cough analysis in clinical medicine is in its infancy. All existing cough analysis approaches are severely handicapped by the limitations of the human hearing range and simplified analysis techniques. In this paper, we address these problems, and explore the use of frequencies covering a range well beyond the human perception (up to 90 kHz) and use wavelet analysis to extract diagnostically important information from coughs. Our data set comes from a pediatric respiratory ward in Indonesia, from subjects diagnosed with asthma, pneumonia and rhinopharyngitis. We analyzed over 90 cough samples from 4 patients and explored if high frequencies carried useful information in separating these disease groups. Multiple regression analysis resulted in coefficients of determination (R(2)) of 77-82% at high frequencies (15 kHz-90 kHz) indicating that they carry useful information. When the high frequencies were combined with frequencies below 15kHz, the R(2) performance increased to 85-90%.

  16. A High Resolution Hydrodynamic Model of Puget Sound to Support Nearshore Restoration Feasibility Analysis and Design

    International Nuclear Information System (INIS)

    Khangaonkar, Tarang; Yang, Zhaoqing

    2011-01-01

    Estuarine and coastal hydrodynamic processes are sometimes neglected in the design and planning of nearshore restoration actions. Despite best intentions, efforts to restore nearshore habitats can result in poor outcomes if circulation and transport which also affect freshwater-saltwater interactions are not properly addressed. Limitations due to current land use can lead to selection of sub-optimal restoration alternatives that may result in undesirable consequences, such as flooding, deterioration of water quality, and erosion, requiring immediate remedies and costly repairs. Uncertainty with achieving restoration goals, such as recovery of tidal exchange, supply of sediment and nutrients, and establishment of fish migration pathways, may be minimized by using numerical models designed for application to the nearshore environment. A high resolution circulation and transport model of the Puget Sound, in the state of Washington, was developed to assist with nearshore habitat restoration design and analysis, and to answer the question 'can we achieve beneficial restoration outcomes at small local scale, as well as at a large estuary-wide scale?' The Puget Sound model is based on an unstructured grid framework to define the complex Puget Sound shoreline using a finite volume coastal ocean model (FVCOM). The capability of the model for simulating the important nearshore processes, such as circulation in complex multiple tidal channels, wetting and drying of tide flats, and water quality and sediment transport as part of restoration feasibility, are illustrated through examples of restoration projects in Puget Sound.

  17. Analysis of financial soundness of manufacturing companies in Indonesia Stock Exchange

    Directory of Open Access Journals (Sweden)

    Widi Hidayat

    2016-07-01

    Full Text Available This study aims to provide information to the issuer and Bapepam and Indonesian Institute of Accountants with additional important information content of ratings and financial soundness of the indicators that do not harm investors. This is an explanatory and descriptive nature of causality using quantitative methods, using all companies listed on the Indonesia Stock Exchange (ISE taken as the sample. The data were analyzed using discriminant statistical analysis tools are processed with SPSS. The results showed that the level of financial soundness of the manufacturing industries listed on the ISE such as 23 (62% Companies Current Asset Growth (CAG is low as well as Fixed Asset growth (FAG 28 (76% companies is still low, Equity Growth (EqG by 27 (73% the company, Revenue growth (RG 27 (65% companies and Net Income Growth (NIG 35 (95% firms. Two manufacturing companies have a very high NIG, thus, NIG average is very high. The seven models of financial soundness were tested based on the growth of corporate finance such as CAG, FAG, LG, EqG, RG, ExG and NIG. Only one model is not significant, the model RG, while the other model is a significant, with a significant difference be-tween the growths rates of the sound and unsound corporate finances industry groups.

  18. Acoustics flow analysis in circular duct using sound intensity and dynamic mode decomposition

    International Nuclear Information System (INIS)

    Weyna, S

    2014-01-01

    Sound intensity generation in hard-walled duct with acoustic flow (no mean-flow) is treated experimentally and shown graphically. In paper, numerous methods of visualization illustrating the vortex flow (2D, 3D) can graphically explain diffraction and scattering phenomena occurring inside the duct and around open end area. Sound intensity investigation in annular duct gives a physical picture of sound waves in any duct mode. In the paper, modal energy analysis are discussed with particular reference to acoustics acoustic orthogonal decomposition (AOD). The image of sound intensity fields before and above 'cut-off' frequency region are found to compare acoustic modes which might resonate in duct. The experimental results show also the effects of axial and swirling flow. However acoustic field is extremely complicated, because pressures in non-propagating (cut-off) modes cooperate with the particle velocities in propagating modes, and vice versa. Measurement in cylindrical duct demonstrates also the cut-off phenomenon and the effect of reflection from open end. The aim of experimental study was to obtain information on low Mach number flows in ducts in order to improve physical understanding and validate theoretical CFD and CAA models that still may be improved.

  19. Scene and character: interdisciplinary analysis of musical and sound symbols for higher education

    Directory of Open Access Journals (Sweden)

    Josep Gustems Carnicer

    2017-01-01

    Full Text Available The aim of this paper is to analyze interdisciplinary and educationally the descriptive aspects of the characters in literature in the world of music (opera, ballet, musical theater, program music, audiovisual, etc. through a wide range of resources and creative processes in various skills that include or encompass the sound. Because of that a literature review and multidisciplinary documentary is done from the most relevant texts and principal authors of the dynamic and stable personality models, from the analysis of vocal features in the scene and in the audiovisuals, from the leitmotiv as a symbol and sound representation of the character, from the the conflicts faced by the characters and how they can overcome them and how we could translated into music those transitions. The subject of myths brought to the world of music scene, character stereotypes and sound symbols that may characterize these scenic and literary content is also addressed. Notably, there is a broad consensus on the use of sound resources to characterize the different characters throughout the history of Western music in its various styles and genres. Furthermore, indications for their use are given and suggestions for activities to higher education suggest.

  20. Determination of the mechanical thermostat electrical contacts switching quality with sound and vibration analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rejc, Jure; Munih, Marko [University of Ljubljana, Ljubljana (Slovenia)

    2017-05-15

    A mechanical thermostat is a device that switches heating or cooling appliances on or off based on temperature. For this kind of use, electronic or mechanical switching concepts are applied. During the production of electrical contacts, several irregularities can occur leading to improper switching events of the thermostat electrical contacts. This paper presents a non-obstructive method based on the fact that when the switching event occurs it can be heard and felt by human senses. We performed several laboratory tests with two different methods. The first method includes thermostat switch sound signal analysis during the switching event. The second method is based on sampling of the accelerometer signal during the switching event. The results show that the sound analysis approach has great potential. The approach enables an accurate determination of the switching event even if the sampled signal carries also the switching event of the neighbour thermostat.

  1. Analysis of the drilling sound component from expert performance in a maxillo-facial surgery

    DEFF Research Database (Denmark)

    Hoffmann, Pablo F.; Gosselin, Florian; Taha, Farid

    2009-01-01

    Auditory displays can have a great potential in surgical simulators that aim at training skills associated to the correct interpretation of auditory information. Here, we present preliminary results in the analysis of the sound produced by the drilling procedure in a maxillo-facial surgery when...... performed by expert surgeons. The motivation of this work is to find relevant acoustic parameters that allow for an efficient synthesis method of auditory displays so that they can effectively convey information on expert surgical drilling....

  2. Cannabis smoking and lung cancer risk: Pooled analysis in the International Lung Cancer Consortium

    OpenAIRE

    Zhang, L.R.; Morgenstern, H.; Greenland, S.; Chang, S.C.; Lazarus, P.; Teare, M.D.; Woll, P.J.; Orlow, I.; Cox, B.; Brhane, Y.; Liu, G.; Hung, R.J.

    2015-01-01

    To investigate the association between cannabis smoking and lung cancer risk, data on 2,159 lung cancer cases and 2,985 controls were pooled from 6 case-control studies in the US, Canada, UK, and New Zealand within the International Lung Cancer Consortium. Study-specific associations between cannabis smoking and lung cancer were estimated using unconditional logistic regression adjusting for sociodemographic factors, tobacco smoking status and pack-years; odds-ratio estimates were pooled usin...

  3. Hemispheric lateralization in an analysis of speech sounds. Left hemisphere dominance replicated in Japanese subjects.

    Science.gov (United States)

    Koyama, S; Gunji, A; Yabe, H; Oiwa, S; Akahane-Yamada, R; Kakigi, R; Näätänen, R

    2000-09-01

    Evoked magnetic responses to speech sounds [R. Näätänen, A. Lehtokoski, M. Lennes, M. Cheour, M. Huotilainen, A. Iivonen, M. Vainio, P. Alku, R.J. Ilmoniemi, A. Luuk, J. Allik, J. Sinkkonen and K. Alho, Language-specific phoneme representations revealed by electric and magnetic brain responses. Nature, 385 (1997) 432-434.] were recorded from 13 Japanese subjects (right-handed). Infrequently presented vowels ([o]) among repetitive vowels ([e]) elicited the magnetic counterpart of mismatch negativity, MMNm (Bilateral, nine subjects; Left hemisphere alone, three subjects; Right hemisphere alone, one subject). The estimated source of the MMNm was stronger in the left than in the right auditory cortex. The sources were located posteriorly in the left than in the right auditory cortex. These findings are consistent with the results obtained in Finnish [R. Näätänen, A. Lehtokoski, M. Lennes, M. Cheour, M. Huotilainen, A. Iivonen, M.Vainio, P.Alku, R.J. Ilmoniemi, A. Luuk, J. Allik, J. Sinkkonen and K. Alho, Language-specific phoneme representations revealed by electric and magnetic brain responses. Nature, 385 (1997) 432-434.][T. Rinne, K. Alho, P. Alku, M. Holi, J. Sinkkonen, J. Virtanen, O. Bertrand and R. Näätänen, Analysis of speech sounds is left-hemisphere predominant at 100-150 ms after sound onset. Neuroreport, 10 (1999) 1113-1117.] and English [K. Alho, J.F. Connolly, M. Cheour, A. Lehtokoski, M. Huotilainen, J. Virtanen, R. Aulanko and R.J. Ilmoniemi, Hemispheric lateralization in preattentive processing of speech sounds. Neurosci. Lett., 258 (1998) 9-12.] subjects. Instead of the P1m observed in Finnish [M. Tervaniemi, A. Kujala, K. Alho, J. Virtanen, R.J. Ilmoniemi and R. Näätänen, Functional specialization of the human auditory cortex in processing phonetic and musical sounds: A magnetoencephalographic (MEG) study. Neuroimage, 9 (1999) 330-336.] and English [K. Alho, J. F. Connolly, M. Cheour, A. Lehtokoski, M. Huotilainen, J. Virtanen, R. Aulanko

  4. Fluid Sounds

    DEFF Research Database (Denmark)

    Explorations and analysis of soundscapes have, since Canadian R. Murray Schafer's work during the early 1970's, developed into various established research - and artistic disciplines. The interest in sonic environments is today present within a broad range of contemporary art projects and in arch......Explorations and analysis of soundscapes have, since Canadian R. Murray Schafer's work during the early 1970's, developed into various established research - and artistic disciplines. The interest in sonic environments is today present within a broad range of contemporary art projects...... and in architectural design. Aesthetics, psychoacoustics, perception, and cognition are all present in this expanding field embracing such categories as soundscape composition, sound art, sonic art, sound design, sound studies and auditory culture. Of greatest significance to the overall field is the investigation...

  5. Diagnosis of Lung Cancer by Fractal Analysis of Damaged DNA

    Directory of Open Access Journals (Sweden)

    Hamidreza Namazi

    2015-01-01

    Full Text Available Cancer starts when cells in a part of the body start to grow out of control. In fact cells become cancer cells because of DNA damage. A DNA walk of a genome represents how the frequency of each nucleotide of a pairing nucleotide couple changes locally. In this research in order to study the cancer genes, DNA walk plots of genomes of patients with lung cancer were generated using a program written in MATLAB language. The data so obtained was checked for fractal property by computing the fractal dimension using a program written in MATLAB. Also, the correlation of damaged DNA was studied using the Hurst exponent measure. We have found that the damaged DNA sequences are exhibiting higher degree of fractality and less correlation compared with normal DNA sequences. So we confirmed this method can be used for early detection of lung cancer. The method introduced in this research not only is useful for diagnosis of lung cancer but also can be applied for detection and growth analysis of different types of cancers.

  6. A Signal Processing Module for the Analysis of Heart Sounds and Heart Murmurs

    International Nuclear Information System (INIS)

    Javed, Faizan; Venkatachalam, P A; H, Ahmad Fadzil M

    2006-01-01

    In this paper a Signal Processing Module (SPM) for the computer-aided analysis of heart sounds has been developed. The module reveals important information of cardiovascular disorders and can assist general physician to come up with more accurate and reliable diagnosis at early stages. It can overcome the deficiency of expert doctors in rural as well as urban clinics and hospitals. The module has five main blocks: Data Acquisition and Pre-processing, Segmentation, Feature Extraction, Murmur Detection and Murmur Classification. The heart sounds are first acquired using an electronic stethoscope which has the capability of transferring these signals to the near by workstation using wireless media. Then the signals are segmented into individual cycles as well as individual components using the spectral analysis of heart without using any reference signal like ECG. Then the features are extracted from the individual components using Spectrogram and are used as an input to a MLP (Multiple Layer Perceptron) Neural Network that is trained to detect the presence of heart murmurs. Once the murmur is detected they are classified into seven classes depending on their timing within the cardiac cycle using Smoothed Pseudo Wigner-Ville distribution. The module has been tested with real heart sounds from 40 patients and has proved to be quite efficient and robust while dealing with a large variety of pathological conditions

  7. A Signal Processing Module for the Analysis of Heart Sounds and Heart Murmurs

    Energy Technology Data Exchange (ETDEWEB)

    Javed, Faizan; Venkatachalam, P A; H, Ahmad Fadzil M [Signal and Imaging Processing and Tele-Medicine Technology Research Group, Department of Electrical and Electronics Engineering, Universiti Teknologi PETRONAS, 31750 Tronoh, Perak (Malaysia)

    2006-04-01

    In this paper a Signal Processing Module (SPM) for the computer-aided analysis of heart sounds has been developed. The module reveals important information of cardiovascular disorders and can assist general physician to come up with more accurate and reliable diagnosis at early stages. It can overcome the deficiency of expert doctors in rural as well as urban clinics and hospitals. The module has five main blocks: Data Acquisition and Pre-processing, Segmentation, Feature Extraction, Murmur Detection and Murmur Classification. The heart sounds are first acquired using an electronic stethoscope which has the capability of transferring these signals to the near by workstation using wireless media. Then the signals are segmented into individual cycles as well as individual components using the spectral analysis of heart without using any reference signal like ECG. Then the features are extracted from the individual components using Spectrogram and are used as an input to a MLP (Multiple Layer Perceptron) Neural Network that is trained to detect the presence of heart murmurs. Once the murmur is detected they are classified into seven classes depending on their timing within the cardiac cycle using Smoothed Pseudo Wigner-Ville distribution. The module has been tested with real heart sounds from 40 patients and has proved to be quite efficient and robust while dealing with a large variety of pathological conditions.

  8. ANALYSIS OF SOUND PRESSURE LEVEL (SPL AND LAY OUT OF ENGINES IN THE FACTORY

    Directory of Open Access Journals (Sweden)

    Wijianto Wijianto

    2017-01-01

    Full Text Available Modeling layout of engines in the factory is very useful to know how many dB sound pressure level that are occur in the building in order to avoid hearing damage of employees that are caused by noise. The objective of this research is to know how many dB sound pressure level that are occur in the factory with engine composition such as boiler, diesel, turbine, motor and gear box with dimension of building are 40 m length, 35 m width and 10 m height. With MATLAB analysis can be obtain that the highest SPL is 104.7 dB and the lowest is 93.5 dB, so, this range are dangerous for human hearing. To avoid hearing damage in this area, employees must use hearing protector.

  9. Emotions while awaiting lung transplantation: A comprehensive qualitative analysis

    Science.gov (United States)

    Brügger, Aurelia; Aubert, John-David

    2014-01-01

    Patients awaiting lung transplantation are at risk of negative emotional and physical experiences. How do they talk about emotions? Semi-structured interviews were performed (15 patients). Categorical analysis focusing on emotion-related descriptions was organized into positive–negative–neutral descriptions: for primary and secondary emotions, evaluation processes, coping strategies, personal characteristics, emotion descriptions associated with physical states, (and) contexts were listed. Patients develop different strategies to maintain positive identity and attitude, while preserving significant others from extra emotional load. Results are discussed within various theoretical and research backgrounds, in emphasizing their importance in the definition of emotional support starting from the patient’s perspective. PMID:28070345

  10. Emotions while awaiting lung transplantation: A comprehensive qualitative analysis.

    Science.gov (United States)

    Brügger, Aurelia; Aubert, John-David; Piot-Ziegler, Chantal

    2014-07-01

    Patients awaiting lung transplantation are at risk of negative emotional and physical experiences. How do they talk about emotions? Semi-structured interviews were performed (15 patients). Categorical analysis focusing on emotion-related descriptions was organized into positive-negative-neutral descriptions: for primary and secondary emotions, evaluation processes, coping strategies, personal characteristics, emotion descriptions associated with physical states, (and) contexts were listed. Patients develop different strategies to maintain positive identity and attitude, while preserving significant others from extra emotional load. Results are discussed within various theoretical and research backgrounds, in emphasizing their importance in the definition of emotional support starting from the patient's perspective.

  11. Emotions while awaiting lung transplantation: A comprehensive qualitative analysis

    Directory of Open Access Journals (Sweden)

    Aurelia Brügger

    2014-12-01

    Full Text Available Patients awaiting lung transplantation are at risk of negative emotional and physical experiences. How do they talk about emotions? Semi-structured interviews were performed (15 patients. Categorical analysis focusing on emotion-related descriptions was organized into positive–negative–neutral descriptions: for primary and secondary emotions, evaluation processes, coping strategies, personal characteristics, emotion descriptions associated with physical states, (and contexts were listed. Patients develop different strategies to maintain positive identity and attitude, while preserving significant others from extra emotional load. Results are discussed within various theoretical and research backgrounds, in emphasizing their importance in the definition of emotional support starting from the patient’s perspective.

  12. A hybrid finite element - statistical energy analysis approach to robust sound transmission modeling

    Science.gov (United States)

    Reynders, Edwin; Langley, Robin S.; Dijckmans, Arne; Vermeir, Gerrit

    2014-09-01

    When considering the sound transmission through a wall in between two rooms, in an important part of the audio frequency range, the local response of the rooms is highly sensitive to uncertainty in spatial variations in geometry, material properties and boundary conditions, which have a wave scattering effect, while the local response of the wall is rather insensitive to such uncertainty. For this mid-frequency range, a computationally efficient modeling strategy is adopted that accounts for this uncertainty. The partitioning wall is modeled deterministically, e.g. with finite elements. The rooms are modeled in a very efficient, nonparametric stochastic way, as in statistical energy analysis. All components are coupled by means of a rigorous power balance. This hybrid strategy is extended so that the mean and variance of the sound transmission loss can be computed as well as the transition frequency that loosely marks the boundary between low- and high-frequency behavior of a vibro-acoustic component. The method is first validated in a simulation study, and then applied for predicting the airborne sound insulation of a series of partition walls of increasing complexity: a thin plastic plate, a wall consisting of gypsum blocks, a thicker masonry wall and a double glazing. It is found that the uncertainty caused by random scattering is important except at very high frequencies, where the modal overlap of the rooms is very high. The results are compared with laboratory measurements, and both are found to agree within the prediction uncertainty in the considered frequency range.

  13. Multi-feature snore sound analysis in obstructive sleep apnea–hypopnea syndrome

    International Nuclear Information System (INIS)

    Karunajeewa, Asela S; Abeyratne, Udantha R; Hukins, Craig

    2011-01-01

    Snoring is the most common symptom of obstructive sleep apnea hypopnea syndrome (OSAHS), which is a serious disease with high community prevalence. The standard method of OSAHS diagnosis, known as polysomnography (PSG), is expensive and time consuming. There is evidence suggesting that snore-related sounds (SRS) carry sufficient information to diagnose OSAHS. In this paper we present a technique for diagnosing OSAHS based solely on snore sound analysis. The method comprises a logistic regression model fed with snore parameters derived from its features such as the pitch and total airway response (TAR) estimated using a higher order statistics (HOS)-based algorithm. Pitch represents a time domain characteristic of the airway vibrations and the TAR represents the acoustical changes brought about by the collapsing upper airways. The performance of the proposed method was evaluated using the technique of K-fold cross validation, on a clinical database consisting of overnight snoring sounds of 41 subjects. The method achieved 89.3% sensitivity with 92.3% specificity (the area under the ROC curve was 0.96). These results establish the feasibility of developing a snore-based OSAHS community-screening device, which does not require any contact measurements

  14. Lung

    International Nuclear Information System (INIS)

    DeNardo, G.L.; Blankenship, W.J.; Burdine, J.A. Jr.; DeNardo, S.J.

    1975-01-01

    At present no simple statement can be made relative to the role of radionuclidic lung studies in the pediatric population. It is safe to assume that they will be used with increasing frequency for research and clinical applications because of their sensitivity and ready applicability to the pediatric patient. Methods comparable to those used in adults can be used in children older than 4 years. In younger children, however, a single injection of 133 Xe in solution provides an index of both regional perfusion and ventilation which is easier to accomplish. This method is particularly valuable in infants and neonates because it is rapid, requires no patient cooperation, results in a very low radiation dose, and can be repeated in serial studies. Radionuclidic studies of ventilation and perfusion can be performed in almost all children if the pediatrician and the nuclear medicine specialist have motivation and ingenuity. S []ontaneous pulmonary vascular occlusive disease which occurs in infants and pulmonary emboli in children are easily detected using radionuclides. The pathophysiologic defects of pulmonary agenesis, bronchopulmonary sequestration, and foreign body aspiration may be demonstrated by these techniques. These techniques also appear to be useful in following patients with bronchial asthma, cystic fibrosis, congenital emphysema, and postinfection pulmonary abnormalities. (auth)

  15. A biomechanical analysis of common lunge tasks in badminton.

    Science.gov (United States)

    Kuntze, Gregor; Mansfield, Neil; Sellers, William

    2010-01-01

    The lunge is regularly used in badminton and is recognized for the high physical demands it places on the lower limbs. Despite its common occurrence, little information is available on the biomechanics of lunging in the singles game. A video-based pilot study confirmed the relatively high frequency of lunging, approximately 15% of all movements, in competitive singles games. The biomechanics and performance characteristics of three badminton-specific lunge tasks (kick, step-in, and hop lunge) were investigated in the laboratory with nine experienced male badminton players. Ground reaction forces and kinematic data were collected and lower limb joint kinetics calculated using an inverse dynamics approach. The step-in lunge was characterized by significantly lower mean horizontal reaction force at drive-off and lower mean peak hip joint power than the kick lunge. The hop lunge resulted in significantly larger mean reaction forces during loading and drive-off phases, as well as significantly larger mean peak ankle joint moments and knee and ankle joint powers than the kick or step-in lunges. These findings indicate that, within the setting of this investigation, the step-in lunge may be beneficial for reducing the muscular demands of lunge recovery and that the hop lunge allows for higher positive power output, thereby presenting an efficient lunging method.

  16. Carbon isotope analysis of carbonaceous compounds in Puget Sound and Lake Washington

    International Nuclear Information System (INIS)

    Swanson, J.R.

    1980-01-01

    A new method has been developed and tested for determining chronological profiles of organic pollutants. This method, Carbon Isotope Analysis (CIA), involves measurements of 12 C, 13 C and 14 C in carbonaceous compounds found in layers of sediment. Lipids, total aliphatic hydrocarbons (TAHs) and polycyclic aromatic hydrocarbons (PAHs) are separated from kg quantities of sediment. Large Soxhlet extractors are used to remove the extractable organics, using ultra-pure benzene-methanol solution and having an extraction efficiency of about 86% for compounds with boiling points higher than n-tetradecane (n-C 14 ). The basic steps in compound separation include freeze-drying, extraction, fractionation, column chromatography and evaporation. Isolating the TAH and PAH fractions is accomplished by eluting samples from Sephadex and alumina/silica-gel columns. The amount of each fraction recovered is determined by converting the hydrocarbons to carbon dioxide and measuring this gas manometrically. Variations in 12 C and 13 C abundances for carbonaceous compounds are primarily due to thermodynamic, photosynthetic and metabolic fractionation processes. Thus, the source of a particular organic compound can often be determined by measuring its 13 C/ 12 C ratio. Combining the information from both the 13 C analysis and 14 C analysis makes source identification more certain. In addition, this investigation reviews carbon isotopic data and carbon cycling and analyzes organic pollution in two limited ecosystems (Puget Sound and Lake Washington). Specifically, distinct carbonaceous species are analyzed for pollution in sediments of Lake Washington, Elliott Bay, Commencement Bay, central Puget Sound and northern Puget Sound near the Cherry Point oil refineries

  17. Computerized comprehensive data analysis of Lung Imaging Database Consortium (LIDC)

    International Nuclear Information System (INIS)

    Tan Jun; Pu Jiantao; Zheng Bin; Wang Xingwei; Leader, Joseph K.

    2010-01-01

    Purpose: Lung Image Database Consortium (LIDC) is the largest public CT image database of lung nodules. In this study, the authors present a comprehensive and the most updated analysis of this dynamically growing database under the help of a computerized tool, aiming to assist researchers to optimally use this database for lung cancer related investigations. Methods: The authors developed a computer scheme to automatically match the nodule outlines marked manually by radiologists on CT images. A large variety of characteristics regarding the annotated nodules in the database including volume, spiculation level, elongation, interobserver variability, as well as the intersection of delineated nodule voxels and overlapping ratio between the same nodules marked by different radiologists are automatically calculated and summarized. The scheme was applied to analyze all 157 examinations with complete annotation data currently available in LIDC dataset. Results: The scheme summarizes the statistical distributions of the abovementioned geometric and diagnosis features. Among the 391 nodules, (1) 365 (93.35%) have principal axis length ≤20 mm; (2) 120, 75, 76, and 120 were marked by one, two, three, and four radiologists, respectively; and (3) 122 (32.48%) have the maximum volume overlapping ratios ≥80% for the delineations of two radiologists, while 198 (50.64%) have the maximum volume overlapping ratios <60%. The results also showed that 72.89% of the nodules were assessed with malignancy score between 2 and 4, and only 7.93% of these nodules were considered as severely malignant (malignancy ≥4). Conclusions: This study demonstrates that LIDC contains examinations covering a diverse distribution of nodule characteristics and it can be a useful resource to assess the performance of the nodule detection and/or segmentation schemes.

  18. Sound speed in the Mediterranean Sea: an analysis from a climatological data set

    Directory of Open Access Journals (Sweden)

    S. Salon

    2003-03-01

    Full Text Available This paper presents an analysis of sound speed distribution in the Mediterranean Sea based on climatological temperature and salinity data. In the upper layers, propagation is characterised by upward refraction in winter and an acoustic channel in summer. The seasonal cycle of the Mediterranean and the presence of gyres and fronts create a wide range of spatial and temporal variabilities, with relevant differences between the western and eastern basins. It is shown that the analysis of a climatological data set can help in defining regions suitable for successful monitoring by means of acoustic tomography. Empirical Orthogonal Functions (EOF decomposition on the profiles, performed on the seasonal cycle for some selected areas, demonstrates that two modes account for more than 98% of the variability of the climatological distribution. Reduced order EOF analysis is able to correctly represent sound speed profiles within each zone, thus providing the a priori knowledge for Matched Field Tomography. It is also demonstrated that salinity can affect the tomographic inversion, creating a higher degree of complexity than in the open oceans.Key words. Oceanography: general (marginal and semi-enclosed seas; ocean acoustics

  19. Microarray Meta-Analysis Identifies Acute Lung Injury Biomarkers in Donor Lungs That Predict Development of Primary Graft Failure in Recipients

    Science.gov (United States)

    Haitsma, Jack J.; Furmli, Suleiman; Masoom, Hussain; Liu, Mingyao; Imai, Yumiko; Slutsky, Arthur S.; Beyene, Joseph; Greenwood, Celia M. T.; dos Santos, Claudia

    2012-01-01

    Objectives To perform a meta-analysis of gene expression microarray data from animal studies of lung injury, and to identify an injury-specific gene expression signature capable of predicting the development of lung injury in humans. Methods We performed a microarray meta-analysis using 77 microarray chips across six platforms, two species and different animal lung injury models exposed to lung injury with or/and without mechanical ventilation. Individual gene chips were classified and grouped based on the strategy used to induce lung injury. Effect size (change in gene expression) was calculated between non-injurious and injurious conditions comparing two main strategies to pool chips: (1) one-hit and (2) two-hit lung injury models. A random effects model was used to integrate individual effect sizes calculated from each experiment. Classification models were built using the gene expression signatures generated by the meta-analysis to predict the development of lung injury in human lung transplant recipients. Results Two injury-specific lists of differentially expressed genes generated from our meta-analysis of lung injury models were validated using external data sets and prospective data from animal models of ventilator-induced lung injury (VILI). Pathway analysis of gene sets revealed that both new and previously implicated VILI-related pathways are enriched with differentially regulated genes. Classification model based on gene expression signatures identified in animal models of lung injury predicted development of primary graft failure (PGF) in lung transplant recipients with larger than 80% accuracy based upon injury profiles from transplant donors. We also found that better classifier performance can be achieved by using meta-analysis to identify differentially-expressed genes than using single study-based differential analysis. Conclusion Taken together, our data suggests that microarray analysis of gene expression data allows for the detection of

  20. Biomarker Identification and Pathway Analysis by Serum Metabolomics of Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yingrong Chen

    2015-01-01

    Full Text Available Lung cancer is one of the most common causes of cancer death, for which no validated tumor biomarker is sufficiently accurate to be useful for diagnosis. Additionally, the metabolic alterations associated with the disease are unclear. In this study, we investigated the construction, interaction, and pathways of potential lung cancer biomarkers using metabolomics pathway analysis based on the Kyoto Encyclopedia of Genes and Genomes database and the Human Metabolome Database to identify the top altered pathways for analysis and visualization. We constructed a diagnostic model using potential serum biomarkers from patients with lung cancer. We assessed their specificity and sensitivity according to the area under the curve of the receiver operator characteristic (ROC curves, which could be used to distinguish patients with lung cancer from normal subjects. The pathway analysis indicated that sphingolipid metabolism was the top altered pathway in lung cancer. ROC curve analysis indicated that glycerophospho-N-arachidonoyl ethanolamine (GpAEA and sphingosine were potential sensitive and specific biomarkers for lung cancer diagnosis and prognosis. Compared with the traditional lung cancer diagnostic biomarkers carcinoembryonic antigen and cytokeratin 19 fragment, GpAEA and sphingosine were as good or more appropriate for detecting lung cancer. We report our identification of potential metabolic diagnostic and prognostic biomarkers of lung cancer and clarify the metabolic alterations in lung cancer.

  1. Listening panel agreement and characteristics of lung sounds digitally recorded from children aged 1–59 months enrolled in the Pneumonia Etiology Research for Child Health (PERCH) case–control study

    Science.gov (United States)

    Park, Daniel E; Watson, Nora L; Buck, W Chris; Bunthi, Charatdao; Devendra, Akash; Ebruke, Bernard E; Elhilali, Mounya; Emmanouilidou, Dimitra; Garcia-Prats, Anthony J; Githinji, Leah; Hossain, Lokman; Madhi, Shabir A; Moore, David P; Mulindwa, Justin; Olson, Dan; Awori, Juliet O; Vandepitte, Warunee P; Verwey, Charl; West, James E; Knoll, Maria D; O'Brien, Katherine L; Feikin, Daniel R; Hammit, Laura L

    2017-01-01

    Introduction Paediatric lung sound recordings can be systematically assessed, but methodological feasibility and validity is unknown, especially from developing countries. We examined the performance of acoustically interpreting recorded paediatric lung sounds and compared sound characteristics between cases and controls. Methods Pneumonia Etiology Research for Child Health staff in six African and Asian sites recorded lung sounds with a digital stethoscope in cases and controls. Cases aged 1–59 months had WHO severe or very severe pneumonia; age-matched community controls did not. A listening panel assigned examination results of normal, crackle, wheeze, crackle and wheeze or uninterpretable, with adjudication of discordant interpretations. Classifications were recategorised into any crackle, any wheeze or abnormal (any crackle or wheeze) and primary listener agreement (first two listeners) was analysed among interpretable examinations using the prevalence-adjusted, bias-adjusted kappa (PABAK). We examined predictors of disagreement with logistic regression and compared case and control lung sounds with descriptive statistics. Results Primary listeners considered 89.5% of 792 case and 92.4% of 301 control recordings interpretable. Among interpretable recordings, listeners agreed on the presence or absence of any abnormality in 74.9% (PABAK 0.50) of cases and 69.8% (PABAK 0.40) of controls, presence/absence of crackles in 70.6% (PABAK 0.41) of cases and 82.4% (PABAK 0.65) of controls and presence/absence of wheeze in 72.6% (PABAK 0.45) of cases and 73.8% (PABAK 0.48) of controls. Controls, tachypnoea, >3 uninterpretable chest positions, crying, upper airway noises and study site predicted listener disagreement. Among all interpretable examinations, 38.0% of cases and 84.9% of controls were normal (p<0.0001); wheezing was the most common sound (49.9%) in cases. Conclusions Listening panel and case–control data suggests our methodology is feasible, likely valid

  2. Sound algorithms

    OpenAIRE

    De Götzen , Amalia; Mion , Luca; Tache , Olivier

    2007-01-01

    International audience; We call sound algorithms the categories of algorithms that deal with digital sound signal. Sound algorithms appeared in the very infancy of computer. Sound algorithms present strong specificities that are the consequence of two dual considerations: the properties of the digital sound signal itself and its uses, and the properties of auditory perception.

  3. Investigation of genesis of gallop sounds in dogs by quantitative phonocardiography and digital frequency analysis.

    Science.gov (United States)

    Aubert, A E; Denys, B G; Meno, F; Reddy, P S

    1985-05-01

    Several investigators have noted external gallop sounds to be of higher amplitude than their corresponding internal sounds (S3 and S4). In this study we hoped to determine if S3 and S4 are transmitted in the same manner as S1. In 11 closed-chest dogs, external (apical) and left ventricular pressures and sounds were recorded simultaneously with transducers with identical sensitivity and frequency responses. Volume and pressure overload and positive and negative inotropic drugs were used to generate gallop sounds. Recordings were made in the control state and after the various interventions. S3 and S4 were recorded in 17 experiments each. The amplitude of the external S1 was uniformly higher than that of internal S1 and internal gallop sounds were inconspicuous. With use of Fourier transforms, the gain function was determined by comparing internal to external S1. By inverse transform, the amplitude of the internal gallop sounds was predicted from external sounds. The internal sounds of significant amplitude were predicted in many instances, but the actual recordings showed no conspicuous sounds. The absence of internal gallop sounds of expected amplitude as calculated from the external gallop sounds and the gain function derived from the comparison of internal and external S1 make it very unlikely that external gallop sounds are derived from internal sounds.

  4. Computer analysis of sound recordings from two Anasazi sites in northwestern New Mexico

    Science.gov (United States)

    Loose, Richard

    2002-11-01

    Sound recordings were made at a natural outdoor amphitheater in Chaco Canyon and in a reconstructed great kiva at Aztec Ruins. Recordings included computer-generated tones and swept sine waves, classical concert flute, Native American flute, conch shell trumpet, and prerecorded music. Recording equipment included analog tape deck, digital minidisk recorder, and direct digital recording to a laptop computer disk. Microphones and geophones were used as transducers. The natural amphitheater lies between the ruins of Pueblo Bonito and Chetro Ketl. It is a semicircular arc in a sandstone cliff measuring 500 ft. wide and 75 ft. high. The radius of the arc was verified with aerial photography, and an acoustic ray trace was generated using cad software. The arc is in an overhanging cliff face and brings distant sounds to a line focus. Along this line, there are unusual acoustic effects at conjugate foci. Time history analysis of recordings from both sites showed that a 60-dB reverb decay lasted from 1.8 to 2.0 s, nearly ideal for public performances of music. Echoes from the amphitheater were perceived to be upshifted in pitch, but this was not seen in FFT analysis. Geophones placed on the floor of the great kiva showed a resonance at 95 Hz.

  5. Making fictions sound real

    DEFF Research Database (Denmark)

    Langkjær, Birger

    2010-01-01

    This article examines the role that sound plays in making fictions perceptually real to film audiences, whether these fictions are realist or non-realist in content and narrative form. I will argue that some aspects of film sound practices and the kind of experiences they trigger are related...... to basic rules of human perception, whereas others are more properly explained in relation to how aesthetic devices, including sound, are used to characterise the fiction and thereby make it perceptually real to its audience. Finally, I will argue that not all genres can be defined by a simple taxonomy...... of sounds. Apart from an account of the kinds of sounds that typically appear in a specific genre, a genre analysis of sound may also benefit from a functionalist approach that focuses on how sounds can make both realist and non-realist aspects of genres sound real to audiences....

  6. Thoracolumbar movement in sound horses trotting in straight lines in hand and on the lunge and the relationship with hind limb symmetry or asymmetry.

    Science.gov (United States)

    Greve, L; Pfau, T; Dyson, S

    2017-02-01

    Equine movement symmetry is changed when turning, which may induce alterations in thoracolumbosacral kinematics; however, this has not previously been investigated. Our objectives were to document thoracolumbar movement in subjectively sound horses comparing straight lines with circles on both reins and to relate these observations to the objectively determined symmetry/asymmetry of hindlimb gait. Fourteen non-lame horses were assessed prospectively in a non-random, cross-sectional survey. The horses were trotted in straight lines and lunged on both reins and inertial sensor data collected at landmarks: withers, T13 and T18, L3, tubera sacrale, and left and right tubera coxae. Data were processed using published methods; angular motion range of motion (ROM; flexion-extension, axial rotation, lateral bending) and translational ROM (dorsoventral and lateral) and symmetry within each stride were assessed. The dorsoventral movement of the back exhibited a sinusoidal pattern with two oscillations per stride. Circles induced greater asymmetry in dorsoventral movement within each stride (mean ± standard deviation, up to 9 ± 6%) compared with straight lines (up to 6 ± 6%). The greatest amplitude of dorsoventral movement (119 ± 14 mm in straight lines vs. 126 ± 20 mm in circles) occurred at T13. Circles induced greater flexion-extension ROM (>1.3°; P = 0.002), lateral bending (>16°; P 16 mm; P = 0.002) compared with straight lines. Circles induced a movement pattern similar to an inside hindlimb lameness, which was significantly associated with the circle-induced greater asymmetry of dorsoventral movement of the thoracolumbar region (P = 0.03). Moving in a circle induces measurable changes in thoracolumbar movement compared with moving in straight lines, associated with alterations in the hindlimb gait. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Risk-benefit analysis and cost-effectiveness analysis of lung cancer screening by spiral CT

    International Nuclear Information System (INIS)

    Iinuma, Takeshi

    1999-01-01

    Mass screening of lung cancer has been widely performed using indirect chest X-ray method in Japan. However reduction of the mortality for lung cancer is questioned. We have proposed that recently developed spiral CT should be adopted for the screening of lung cancer, since CT has an excellent detectability for small nodule. Lung Cancer Screening CT (LSCT) has been developed by author's group using spiral CT with low dose and light weight in order to make a mobile unit. In this paper risk-benefit analysis and cost-effectiveness analysis are described for the LSCT screening of lung cancer. As a risk, radiation carcinogenesis due to exposure from LSCT are compared with gain of life-expectancy by screening and men of 40 years or more and women of 45 years or more are justified. The cost per person-year is estimated for LSCT screening which is better than that of present method, although total cost is higher. The LSCT screening could be recommended if total cost is affordable. (author)

  8. Chaotic dynamics of respiratory sounds

    International Nuclear Information System (INIS)

    Ahlstrom, C.; Johansson, A.; Hult, P.; Ask, P.

    2006-01-01

    There is a growing interest in nonlinear analysis of respiratory sounds (RS), but little has been done to justify the use of nonlinear tools on such data. The aim of this paper is to investigate the stationarity, linearity and chaotic dynamics of recorded RS. Two independent data sets from 8 + 8 healthy subjects were recorded and investigated. The first set consisted of lung sounds (LS) recorded with an electronic stethoscope and the other of tracheal sounds (TS) recorded with a contact accelerometer. Recurrence plot analysis revealed that both LS and TS are quasistationary, with the parts corresponding to inspiratory and expiratory flow plateaus being stationary. Surrogate data tests could not provide statistically sufficient evidence regarding the nonlinearity of the data. The null hypothesis could not be rejected in 4 out of 32 LS cases and in 15 out of 32 TS cases. However, the Lyapunov spectra, the correlation dimension (D 2 ) and the Kaplan-Yorke dimension (D KY ) all indicate chaotic behavior. The Lyapunov analysis showed that the sum of the exponents was negative in all cases and that the largest exponent was found to be positive. The results are partly ambiguous, but provide some evidence of chaotic dynamics of RS, both concerning LS and TS. The results motivate continuous use of nonlinear tools for analysing RS data

  9. Chaotic dynamics of respiratory sounds

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstrom, C. [Department of Biomedical Engineering, Linkoepings Universitet, IMT/LIU, Universitetssjukhuset, S-58185 Linkoeping (Sweden) and Biomedical Engineering, Orebro University Hospital, S-70185 Orebro (Sweden)]. E-mail: christer@imt.liu.se; Johansson, A. [Department of Biomedical Engineering, Linkoepings Universitet, IMT/LIU, Universitetssjukhuset, S-58185 Linkoeping (Sweden); Hult, P. [Department of Biomedical Engineering, Linkoepings Universitet, IMT/LIU, Universitetssjukhuset, S-58185 Linkoeping (Sweden); Biomedical Engineering, Orebro University Hospital, S-70185 Orebro (Sweden); Ask, P. [Department of Biomedical Engineering, Linkoepings Universitet, IMT/LIU, Universitetssjukhuset, S-58185 Linkoeping (Sweden); Biomedical Engineering, Orebro University Hospital, S-70185 Orebro (Sweden)

    2006-09-15

    There is a growing interest in nonlinear analysis of respiratory sounds (RS), but little has been done to justify the use of nonlinear tools on such data. The aim of this paper is to investigate the stationarity, linearity and chaotic dynamics of recorded RS. Two independent data sets from 8 + 8 healthy subjects were recorded and investigated. The first set consisted of lung sounds (LS) recorded with an electronic stethoscope and the other of tracheal sounds (TS) recorded with a contact accelerometer. Recurrence plot analysis revealed that both LS and TS are quasistationary, with the parts corresponding to inspiratory and expiratory flow plateaus being stationary. Surrogate data tests could not provide statistically sufficient evidence regarding the nonlinearity of the data. The null hypothesis could not be rejected in 4 out of 32 LS cases and in 15 out of 32 TS cases. However, the Lyapunov spectra, the correlation dimension (D {sub 2}) and the Kaplan-Yorke dimension (D {sub KY}) all indicate chaotic behavior. The Lyapunov analysis showed that the sum of the exponents was negative in all cases and that the largest exponent was found to be positive. The results are partly ambiguous, but provide some evidence of chaotic dynamics of RS, both concerning LS and TS. The results motivate continuous use of nonlinear tools for analysing RS data.

  10. Computerised Analysis of Telemonitored Respiratory Sounds for Predicting Acute Exacerbations of COPD.

    Science.gov (United States)

    Fernandez-Granero, Miguel Angel; Sanchez-Morillo, Daniel; Leon-Jimenez, Antonio

    2015-10-23

    Chronic obstructive pulmonary disease (COPD) is one of the commonest causes of death in the world and poses a substantial burden on healthcare systems and patients' quality of life. The largest component of the related healthcare costs is attributable to admissions due to acute exacerbation (AECOPD). The evidence that might support the effectiveness of the telemonitoring interventions in COPD is limited partially due to the lack of useful predictors for the early detection of AECOPD. Electronic stethoscopes and computerised analyses of respiratory sounds (CARS) techniques provide an opportunity for substantial improvement in the management of respiratory diseases. This exploratory study aimed to evaluate the feasibility of using: (a) a respiratory sensor embedded in a self-tailored housing for ageing users; (b) a telehealth framework; (c) CARS and (d) machine learning techniques for the remote early detection of the AECOPD. In a 6-month pilot study, 16 patients with COPD were equipped with a home base-station and a sensor to daily record their respiratory sounds. Principal component analysis (PCA) and a support vector machine (SVM) classifier was designed to predict AECOPD. 75.8% exacerbations were early detected with an average of 5 ± 1.9 days in advance at medical attention. The proposed method could provide support to patients, physicians and healthcare systems.

  11. Multi-point accelerometric detection and principal component analysis of heart sounds

    International Nuclear Information System (INIS)

    De Panfilis, S; Peccianti, M; Chiru, O M; Moroni, C; Vashkevich, V; Parisi, G; Cassone, R

    2013-01-01

    Heart sounds are a fundamental physiological variable that provide a unique insight into cardiac semiotics. However a deterministic and unambiguous association between noises in cardiac dynamics is far from being accomplished yet due to many and different overlapping events which contribute to the acoustic emission. The current computer-based capacities in terms of signal detection and processing allow one to move from the standard cardiac auscultation, even in its improved forms like electronic stethoscopes or hi-tech phonocardiography, to the extraction of information on the cardiac activity previously unexplored. In this report, we present a new equipment for the detection of heart sounds, based on a set of accelerometric sensors placed in contact with the chest skin on the precordial area, and are able to measure simultaneously the vibration induced on the chest surface by the heart's mechanical activity. By utilizing advanced algorithms for the data treatment, such as wavelet decomposition and principal component analysis, we are able to condense the spatially extended acoustic information and to provide a synthetical representation of the heart activity. We applied our approach to 30 adults, mixed per gender, age and healthiness, and correlated our results with standard echocardiographic examinations. We obtained a 93% concordance rate with echocardiography between healthy and unhealthy hearts, including minor abnormalities such as mitral valve prolapse. (fast track communication)

  12. Puget Sound Area Electric Reliability Plan : Appendix E, Transmission Reinforcement Analysis.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1992-04-01

    The purpose of this appendix to the draft environmental impact statement (EIS) report is to provide an update of the latest study work done on transmission system options for the Puget Sound Area Electric Reliability Plan. Also included in the attachments to the EIS are 2 reports analyzing the voltage stability of the Puget Sound transmission system and a review by Power Technologies, Inc. of the BPA voltage stability analysis and reactive options. Five transmission line options and several reactive options are presently being considered as possible solutions to the PSAFRP by the Transmission Team. The first two line options would be built on new rights-of way adjacent (as much as possible) to existing corridors. The reactive options would optimize the existing transmission system capability by adding new stations for series capacitors and/or switchgear. The other three line options are rebuilds or upgrades of existing cross mountain transmission lines. These options are listed below and include a preliminary assessment of the additional transmission system reinforcement required to integrate the new facilities into the existing transmission system. Plans were designed to provide at least 500 MVAR reactive margin.

  13. Computerised Analysis of Telemonitored Respiratory Sounds for Predicting Acute Exacerbations of COPD

    Directory of Open Access Journals (Sweden)

    Miguel Angel Fernandez-Granero

    2015-10-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is one of the commonest causes of death in the world and poses a substantial burden on healthcare systems and patients’ quality of life. The largest component of the related healthcare costs is attributable to admissions due to acute exacerbation (AECOPD. The evidence that might support the effectiveness of the telemonitoring interventions in COPD is limited partially due to the lack of useful predictors for the early detection of AECOPD. Electronic stethoscopes and computerised analyses of respiratory sounds (CARS techniques provide an opportunity for substantial improvement in the management of respiratory diseases. This exploratory study aimed to evaluate the feasibility of using: (a a respiratory sensor embedded in a self-tailored housing for ageing users; (b a telehealth framework; (c CARS and (d machine learning techniques for the remote early detection of the AECOPD. In a 6-month pilot study, 16 patients with COPD were equipped with a home base-station and a sensor to daily record their respiratory sounds. Principal component analysis (PCA and a support vector machine (SVM classifier was designed to predict AECOPD. 75.8% exacerbations were early detected with an average of 5 ± 1.9 days in advance at medical attention. The proposed method could provide support to patients, physicians and healthcare systems.

  14. Lung sound analysis can be an index of the control of bronchial asthma

    Directory of Open Access Journals (Sweden)

    Terufumi Shimoda

    2017-01-01

    Conclusions: The E/I LF measurement obtained by LSA is useful as an indicator of changes in airway obstruction and inflammation and can be used for monitoring the therapeutic course of bronchial asthma patients.

  15. Noninvasive detection of lung cancer by analysis of exhaled breath

    OpenAIRE

    Bajtarevic, Amel; Ager, Clemens; Pienz, Martin; Klieber, Martin; Schwarz, Konrad; Ligor, Magdalena; Ligor, Tomasz; Filipiak, Wojciech; Denz, Hubert; Fiegl, Michael; Hilbe, Wolfgang; Weiss, Wolfgang; Lukas, Peter; Jamnig, Herbert; Hackl, Martin

    2009-01-01

    Abstract Background Lung cancer is one of the leading causes of death in Europe and the western world. At present, diagnosis of lung cancer very often happens late in the course of the disease since inexpensive, non-invasive and sufficiently sensitive and specific screening methods are not available. Even though the CT diagnostic methods are good, it must be assured that "screening benefit outweighs risk, across all individuals screened, not only those with lung cancer". An early non-invasive...

  16. [Survey and analysis of awareness of lung cancer prevention and control in a LDCT lung cancer screening project in Tianjin Dagang Oilfield of China].

    Science.gov (United States)

    Ren, Guanhua; Ye, Jianfei; Fan, Yaguang; Wang, Jing; Sun, Zhijuan; Jia, Hui; Du, Xinxin; Hou, Chaohua; Wang, Ying; Zhao, Yongcheng; Zhou, Qinghua

    2014-02-01

    It has been proven that increase of the awareness level of lung cancer prevention and control could enhance participation of lung cancer screening of lung cancer high risk group. The aim of this study is to investigate the awareness level of lung cancer prevention and control and the effect of individual characteristics on lung cancer awareness, and to provide evidence for comprehensive lung cancer prevention in high risk areas of lung cancer. Staffs of Tianjin Dagang Oil Field who participate low dose CT (LDCT) lung cancer screening by cluster sampling or according to voluntary principle were surveyed, data of lung cancer awareness were collected by questionnaire. A total of 1,633 valid questionnaires were collected. The average age of respondents was 60.08±6.58. Most participants were males (82.2%) while female only accounted for 17.8%. The proportions of awareness about lung cancer in China, risk factors, screening methods and the knowledge of health examination were 64.5%, 77.1%, 43.7%, 49.6% respectively. Result of multiple logistic regression analysis showed that education level, smoking (pack-year), age, prior tuberculosis were the influencing factors of lung cancer awareness with adjusted Ors for education and age level as of 0.567 (95%CI: 0.439-0.733) and 1.373 (95%CI: 1.084-1.739) respectively. 80.3% of the participants can accept health examination once a year, while the ability to pay the medical expenses was not high. The influencing factors of health examination willingness were gender, age, income, the knowledge of lung cancer. Education level and smoking affect the awareness of lung cancer prevention and control, health education for lung cancer should be conducted especially in population with low education level. Comprehensive lung cancer control in high risk areas should combined lung cancer screening, tobacco control and health education.

  17. Contemporary state of the problem of radiation lesions of the lungs: scientometric analysis

    International Nuclear Information System (INIS)

    Artamonova, N.O.; Kulyinyich, G.V.; Gajsenyuk, L.O.; Masyich, O.V.; Pavlyichenko, Yu.V.

    2011-01-01

    Scientometric analysis of the contemporary state and prospects of development of the problem of lung radiation lesion allowed to prove its urgency. But among separate questions, the most important is solving the problem of lung radiation toxicity. The majority of publications about clinical trials suggest about a constant search for new means of prevention and treatment. It was established that the information search efficacy about lung radiation lesions depended on the adequate use of term corpus of PubMed database.

  18. Clinical analysis of lung cancer complicated by pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Sugino, Keishi; Homma, Sakae; Miyamoto, Atsushi; Takaya, Hisashi; Sakamoto, Susumu; Kawabata, Masateru; Kishi, Kazuma; Tsuboi, Eiyasu; Yoshimura, Kunihiko

    2007-01-01

    The aim of this study was to assess the characteristic clinical features of lung cancer associated with pulmonary tuberculosis. Among 1,028 patients with pulmonary tuberculosis admitted in our hospital between 1985 and 2005, 17 (15 men, 2 women; mean age 73±8) were diagnosed as having lung cancer. Patient characteristics, clinical features, radiographic images, treatment and prognosis were evaluated retrospectively. Patients were classified into 2 groups: group A (n=5), lung cancer complicated by active tuberculosis, and group B (n=12), lung cancer with tuberculosis sequelae. All patients in group A and 8 patients (33%) in group B had either stage III or IV lung cancer, whereas 4 patients in group B had stage I lung cancer. Coexistence of lung cancer and pulmonary tuberculosis in the same segment or lobe was seen in 80% (n=4) or 60% (n=3) of group A cases, respectively, and in 67% (n=8) or 8% (n=1) respectively, in group B. Mean survival in group A and group B was 9.2 months and 26.8 months, respectively. More attention should be paid to the possibility of development of lung cancer in individuals with a history of pulmonary tuberculosis or who have had tuberculosis sequelae revealed by chest radiography. Also, the possible coexistence of lung cancer must be carefully examined in patients with active pulmonary tuberculosis. (author)

  19. Histogram based analysis of lung perfusion of children after congenital diaphragmatic hernia repair.

    Science.gov (United States)

    Kassner, Nora; Weis, Meike; Zahn, Katrin; Schaible, Thomas; Schoenberg, Stefan O; Schad, Lothar R; Zöllner, Frank G

    2018-05-01

    To investigate a histogram based approach to characterize the distribution of perfusion in the whole left and right lung by descriptive statistics and to show how histograms could be used to visually explore perfusion defects in two year old children after Congenital Diaphragmatic Hernia (CDH) repair. 28 children (age of 24.2±1.7months; all left sided hernia; 9 after extracorporeal membrane oxygenation therapy) underwent quantitative DCE-MRI of the lung. Segmentations of left and right lung were manually drawn to mask the calculated pulmonary blood flow maps and then to derive histograms for each lung side. Individual and group wise analysis of histograms of left and right lung was performed. Ipsilateral and contralateral lung show significant difference in shape and descriptive statistics derived from the histogram (Wilcoxon signed-rank test, phistogram derived parameters. Histogram analysis can be a valuable tool to characterize and visualize whole lung perfusion of children after CDH repair. It allows for several possibilities to analyze the data, either describing the perfusion differences between the right and left lung but also to explore and visualize localized perfusion patterns in the 3D lung volume. Subgroup analysis will be possible given sufficient sample sizes. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Software development for the analysis of heartbeat sounds with LabVIEW in diagnosis of cardiovascular disease.

    Science.gov (United States)

    Topal, Taner; Polat, Hüseyin; Güler, Inan

    2008-10-01

    In this paper, a time-frequency spectral analysis software (Heart Sound Analyzer) for the computer-aided analysis of cardiac sounds has been developed with LabVIEW. Software modules reveal important information for cardiovascular disorders, it can also assist to general physicians to come up with more accurate and reliable diagnosis at early stages. Heart sound analyzer (HSA) software can overcome the deficiency of expert doctors and help them in rural as well as urban clinics and hospitals. HSA has two main blocks: data acquisition and preprocessing, time-frequency spectral analyses. The heart sounds are first acquired using a modified stethoscope which has an electret microphone in it. Then, the signals are analysed using the time-frequency/scale spectral analysis techniques such as STFT, Wigner-Ville distribution and wavelet transforms. HSA modules have been tested with real heart sounds from 35 volunteers and proved to be quite efficient and robust while dealing with a large variety of pathological conditions.

  1. The Textile Form of Sound

    DEFF Research Database (Denmark)

    Bendixen, Cecilie

    Sound is a part of architecture, and sound is complex. Upon this, sound is invisible. How is it then possible to design visual objects that interact with the sound? This paper addresses the problem of how to get access to the complexity of sound and how to make textile material revealing the form...... goemetry by analysing the sound pattern at a specific spot. This analysis is done theoretically with algorithmic systems and practical with waves in water. The paper describes the experiments and the findings, and explains how an analysis of sound can be catched in a textile form....

  2. A novel murmur-based heart sound feature extraction technique using envelope-morphological analysis

    Science.gov (United States)

    Yao, Hao-Dong; Ma, Jia-Li; Fu, Bin-Bin; Wang, Hai-Yang; Dong, Ming-Chui

    2015-07-01

    Auscultation of heart sound (HS) signals serves as an important primary approach to diagnose cardiovascular diseases (CVDs) for centuries. Confronting the intrinsic drawbacks of traditional HS auscultation, computer-aided automatic HS auscultation based on feature extraction technique has witnessed explosive development. Yet, most existing HS feature extraction methods adopt acoustic or time-frequency features which exhibit poor relationship with diagnostic information, thus restricting the performance of further interpretation and analysis. Tackling such a bottleneck problem, this paper innovatively proposes a novel murmur-based HS feature extraction method since murmurs contain massive pathological information and are regarded as the first indications of pathological occurrences of heart valves. Adapting discrete wavelet transform (DWT) and Shannon envelope, the envelope-morphological characteristics of murmurs are obtained and three features are extracted accordingly. Validated by discriminating normal HS and 5 various abnormal HS signals with extracted features, the proposed method provides an attractive candidate in automatic HS auscultation.

  3. Fascicle behaviour analysis during forward lunge exercise: the ...

    African Journals Online (AJOL)

    This study was conducted to determine and compare the fascicle behaviour during forward lunge exercise with different loadings lifted. Thirty recreationally active, untrained men (mean age = 21 ± 0.83 years old) were recruited and were assigned to perform forward lunge with 30% 1RM (30FL) and 70% 1RM (70FL) with ...

  4. Kinetics analysis of step and jump forward lunge among badminton ...

    African Journals Online (AJOL)

    This study was conducted to determine and compare the kinetics during step forward lunge (SFL) and jump forward lunge (JFL) in badminton. Fifteen university badminton players (mean age = 22.07 ± 1.39 years old) were recruited and were assigned to perform SFL and JFL while holding a badminton racquet using their ...

  5. Wheeze sound analysis using computer-based techniques: a systematic review.

    Science.gov (United States)

    Ghulam Nabi, Fizza; Sundaraj, Kenneth; Chee Kiang, Lam; Palaniappan, Rajkumar; Sundaraj, Sebastian

    2017-10-31

    Wheezes are high pitched continuous respiratory acoustic sounds which are produced as a result of airway obstruction. Computer-based analyses of wheeze signals have been extensively used for parametric analysis, spectral analysis, identification of airway obstruction, feature extraction and diseases or pathology classification. While this area is currently an active field of research, the available literature has not yet been reviewed. This systematic review identified articles describing wheeze analyses using computer-based techniques on the SCOPUS, IEEE Xplore, ACM, PubMed and Springer and Elsevier electronic databases. After a set of selection criteria was applied, 41 articles were selected for detailed analysis. The findings reveal that 1) computerized wheeze analysis can be used for the identification of disease severity level or pathology, 2) further research is required to achieve acceptable rates of identification on the degree of airway obstruction with normal breathing, 3) analysis using combinations of features and on subgroups of the respiratory cycle has provided a pathway to classify various diseases or pathology that stem from airway obstruction.

  6. New perspectives in monitoring lung inflammation: analysis of exhaled breath condensate

    National Research Council Canada - National Science Library

    Montuschi, Paolo

    2005-01-01

    ... diseases might be relevant to differential diagnosis. Given its noninvasiveness, this method might be suitable for longitudinal studies in patients with lung disease, including children. This book provides an introduction to the analysis of exhaled breath condensate. To provide an overview of lung inflammation, basic and clinical pharmacology of leukotrie...

  7. Application of neutron activation analysis to trace elements determinations in lung samples

    International Nuclear Information System (INIS)

    Rogero, S.O.

    1991-01-01

    The purpose of this work was to apply the instrumental neutron activation analysis method to determine trace elements in lung samples from smokers and non smokers. Samples of lung tissues and lymph nodes from pulmonary hilum analyzed were collected from autopsies by researchers from Faculdade de Medicina da USP. (author)

  8. First experience with energy dispersive X-ray analysis (EDXA) in lung fibrosis

    International Nuclear Information System (INIS)

    Liebetrau, G.; Wiesner, B.; Strausz, J.; Zglinicki, T. von

    1987-01-01

    Biopsies from 68 patients suffering from interstitial lung disease were examined with regard to minerals using energy dispersive X-ray analysis. In 31 patients a higher portion of minerals or elements were found as pigments. The interpretation of these findings is difficult. If there is a occupational exposure and a reaction of the lung parenchyma the findings could be of clinical value. (author)

  9. Foley Sounds vs Real Sounds

    DEFF Research Database (Denmark)

    Trento, Stefano; Götzen, Amalia De

    2011-01-01

    This paper is an initial attempt to study the world of sound effects for motion pictures, also known as Foley sounds. Throughout several audio and audio-video tests we have compared both Foley and real sounds originated by an identical action. The main purpose was to evaluate if sound effects...

  10. Sound extinction by fish schools: forward scattering theory and data analysis.

    Science.gov (United States)

    Raveau, M; Feuillade, C

    2015-02-01

    A model used previously to study collective back scattering from fish schools [Feuillade et al., J. Acoust. Soc. Am. 99(1), 196-208 (1996)], is used to analyze the forward scattering properties of these objects. There is an essential physical difference between back and forward scattering from fish schools. Strong frequency dependent interference effects, which affect the back scattered field amplitude, are absent in the forward scattering case. This is critically important for data analysis. There is interest in using back scattering and transmission data from fish schools to study their size, the species and abundance of fish, and fish behavior. Transmission data can be processed to determine the extinction of the field by a school. The extinction of sound depends on the forward scattering characteristics of the school, and data inversion to provide information about the fish should be based upon a forward scattering paradigm. Results are presented of an analysis of transmission data obtained in September 1995 during an experiment performed in the Gulf of Lion in the Mediterranean Sea [Diachok, J. Acoust. Soc. Am. 105(4), 2107-2128 (1999)]. The analysis shows that using forward scattering leads to significantly larger estimates of fish abundance than previous analysis based upon back scattering approaches.

  11. Aurally-adequate time-frequency analysis for scattered sound in auditoria

    Science.gov (United States)

    Norris, Molly K.; Xiang, Ning; Kleiner, Mendel

    2005-04-01

    The goal of this work was to apply an aurally-adequate time-frequency analysis technique to the analysis of sound scattering effects in auditoria. Time-frequency representations were developed as a motivated effort that takes into account binaural hearing, with a specific implementation of interaural cross-correlation process. A model of the human auditory system was implemented in the MATLAB platform based on two previous models [A. Härmä and K. Palomäki, HUTear, Espoo, Finland; and M. A. Akeroyd, A. Binaural Cross-correlogram Toolbox for MATLAB (2001), University of Sussex, Brighton]. These stages include proper frequency selectivity, the conversion of the mechanical motion of the basilar membrane to neural impulses, and binaural hearing effects. The model was then used in the analysis of room impulse responses with varying scattering characteristics. This paper discusses the analysis results using simulated and measured room impulse responses. [Work supported by the Frank H. and Eva B. Buck Foundation.

  12. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Preite Martinez, A; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C

    2007-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  13. Analysis of failure of voice production by a sound-producing voice prosthesis

    NARCIS (Netherlands)

    van der Torn, M.; van Gogh, C.D.L.; Verdonck-de Leeuw, I M; Festen, J.M.; Mahieu, H.F.

    OBJECTIVE: To analyse the cause of failing voice production by a sound-producing voice prosthesis (SPVP). METHODS: The functioning of a prototype SPVP is described in a female laryngectomee before and after its sound-producing mechanism was impeded by tracheal phlegm. This assessment included:

  14. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  15. Breeding soundness evaluation of bulls by semen analysis, testicular fine needle aspiration cytology and trans-scrotal ultrasonography

    Directory of Open Access Journals (Sweden)

    Chapwanya A

    2008-05-01

    Full Text Available Abstract The aim of this study was to evaluate the usefulness of trans-scrotal ultrasonography and testicular fine needle aspiration cytology in assessing bulls for breeding suitability. These two techniques were also compared with semen analysis. Bulls presented for breeding soundness evaluation were assessed using all three techniques. The findings of each technique were compared. There was agreement in classification of fertile bulls using all three techniques, suggesting that the combined use of these techniques enhances routine breeding soundness examination. Use of the three techniques also enhances detailed investigation of suspected sub-fertile bulls while accurately identifying testicular cause(s of sire sub-fertility.

  16. Applying cybernetic technology to diagnose human pulmonary sounds.

    Science.gov (United States)

    Chen, Mei-Yung; Chou, Cheng-Han

    2014-06-01

    Chest auscultation is a crucial and efficient method for diagnosing lung disease; however, it is a subjective process that relies on physician experience and the ability to differentiate between various sound patterns. Because the physiological signals composed of heart sounds and pulmonary sounds (PSs) are greater than 120 Hz and the human ear is not sensitive to low frequencies, successfully making diagnostic classifications is difficult. To solve this problem, we constructed various PS recognition systems for classifying six PS classes: vesicular breath sounds, bronchial breath sounds, tracheal breath sounds, crackles, wheezes, and stridor sounds. First, we used a piezoelectric microphone and data acquisition card to acquire PS signals and perform signal preprocessing. A wavelet transform was used for feature extraction, and the PS signals were decomposed into frequency subbands. Using a statistical method, we extracted 17 features that were used as the input vectors of a neural network. We proposed a 2-stage classifier combined with a back-propagation (BP) neural network and learning vector quantization (LVQ) neural network, which improves classification accuracy by using a haploid neural network. The receiver operating characteristic (ROC) curve verifies the high performance level of the neural network. To expand traditional auscultation methods, we constructed various PS diagnostic systems that can correctly classify the six common PSs. The proposed device overcomes the lack of human sensitivity to low-frequency sounds and various PS waves, characteristic values, and a spectral analysis charts are provided to elucidate the design of the human-machine interface.

  17. Dietary Cholesterol Intake and Risk of Lung Cancer: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Xiaojing Lin

    2018-02-01

    Full Text Available Multiple epidemiologic studies have evaluated the relationship between dietary cholesterol and lung cancer risk, but the association is controversial and inconclusive. A meta-analysis of case-control studies and cohort studies was conducted to evaluate the relationship between dietary cholesterol intake and lung cancer risk in this study. A relevant literature search up to October 2017 was performed in Web of Science, PubMed, China National Knowledge Infrastructure, Sinomed, and VIP Journal Integration Platform. Ten case-control studies and six cohort studies were included in the meta-analysis, and the risk estimates were pooled using either fixed or random effects models. The case-control studies with a total of 6894 lung cancer cases and 29,736 controls showed that dietary cholesterol intake was positively associated with lung cancer risk (Odds Ratio = 1.70, 95% Confidence Interval: 1.43–2.03. However, there was no evidence of an association between dietary cholesterol intake and risk of lung cancer among the 241,920 participants and 1769 lung cancer cases in the cohort studies (Relative Risk = 1.08, 95% Confidence Interval: 0.94–1.25. Due to inconsistent results from case-control and cohort studies, it is difficult to draw any conclusion regarding the effects of dietary cholesterol intake on lung cancer risk. Carefully designed and well-conducted cohort studies are needed to identify the association between dietary cholesterol and lung cancer risk.

  18. Spectro-temporal analysis of complex tones: two cortical processes dependent on retention of sounds in the long auditory store.

    Science.gov (United States)

    Jones, S J; Vaz Pato, M; Sprague, L

    2000-09-01

    To examine whether two cortical processes concerned with spectro-temporal analysis of complex tones, a 'C-process' generating CN1 and CP2 potentials at cf. 100 and 180 ms after sudden change of pitch or timbre, and an 'M-process' generating MN1 and MP2 potentials of similar latency at the sudden cessation of repeated changes, are dependent on accumulation of a sound image in the long auditory store. The durations of steady (440 Hz) and rapidly oscillating (440-494 Hz, 16 changes/s) pitch of a synthesized 'clarinet' tone were reciprocally varied between 0.5 and 4.5 s within a duty cycle of 5 s. Potentials were recorded at the beginning and end of the period of oscillation in 10 non-attending normal subjects. The CN1 at the beginning of pitch oscillation and the MN1 at the end were both strongly influenced by the duration of the immediately preceding stimulus pattern, mean amplitudes being 3-4 times larger after 4.5 s as compared with 0.5 s. The processes responsible for both CN1 and MN1 are influenced by the duration of the preceding sound pattern over a period comparable to that of the 'echoic memory' or long auditory store. The store therefore appears to occupy a key position in spectro-temporal sound analysis. The C-process is concerned with the spectral structure of complex sounds, and may therefore reflect the 'grouping' of frequency components underlying auditory stream segregation. The M-process (mismatch negativity) is concerned with the temporal sound structure, and may play an important role in the extraction of information from sequential sounds.

  19. Kinematic Analysis of Speech Sound Sequencing Errors Induced by Delayed Auditory Feedback.

    Science.gov (United States)

    Cler, Gabriel J; Lee, Jackson C; Mittelman, Talia; Stepp, Cara E; Bohland, Jason W

    2017-06-22

    Delayed auditory feedback (DAF) causes speakers to become disfluent and make phonological errors. Methods for assessing the kinematics of speech errors are lacking, with most DAF studies relying on auditory perceptual analyses, which may be problematic, as errors judged to be categorical may actually represent blends of sounds or articulatory errors. Eight typical speakers produced nonsense syllable sequences under normal and DAF (200 ms). Lip and tongue kinematics were captured with electromagnetic articulography. Time-locked acoustic recordings were transcribed, and the kinematics of utterances with and without perceived errors were analyzed with existing and novel quantitative methods. New multivariate measures showed that for 5 participants, kinematic variability for productions perceived to be error free was significantly increased under delay; these results were validated by using the spatiotemporal index measure. Analysis of error trials revealed both typical productions of a nontarget syllable and productions with articulatory kinematics that incorporated aspects of both the target and the perceived utterance. This study is among the first to characterize articulatory changes under DAF and provides evidence for different classes of speech errors, which may not be perceptually salient. New methods were developed that may aid visualization and analysis of large kinematic data sets. https://doi.org/10.23641/asha.5103067.

  20. CT analysis of lung cancer and coexistent emphysema

    International Nuclear Information System (INIS)

    Noh, Kyung Hee; Chung, Myung Hee; Sung, Mi Sook; Yoo, Won Jong; Son, Kyung Myung; Son, Jung Min; Park, Seog Hee

    2004-01-01

    To evaluate the relation of the location and cell type of lung cancer to the location and degree in coexistent emphysema on high-resolution computed tomography (HRCT) scans. Ninety-eight of 209 lung cancer patients having HRCT scans were retrospectively analyzed to assess the total lung emphysema and peritumoral regional emphysema. Single and primary lung cancers were included. The clinical data, including sex, age, smoking history and the pathologic cancer subtype, were recorded to correlate with the HRCT findings. The lobar distribution, central-peripheral predominance, surrounding parenchymal abnormality for cancer, cephalocaudal predominance, and subtype for emphysema were analyzed on HRCT. Using a CT scoring method, we scored the whole lung emphysema and peritumoral emphysema, and correlated the grading of emphysema with pulmonary functional values. Sixty-nine of 98 patients with lung cancer (71%) had emphysema. Lung cancer with emphysema was significantly higher in men than in women, and was significantly related to smoking. The mean age of cancer patients without emphysema was significantly lower than that of cancer patients with emphysema (68 yrs vs. 61 yrs, p= 0.0006). Emphysema of grade I (0-25%) was found in 52 cases, grade II (25-50%) in 15, and grade III (50-75%) in 2. Total emphysema score was paralleled to peritumoral emphysema score in 64.3%, while the remaining patients had a higher peritumoral emphysema score (grade II or III) than total emphysema score (grade 0 or I). There was no statistical correlation in the developmental location between the emphysema and the lung cancer (significant correlation was only noted in grade II group of total emphysema score). The incidence of non-small cell carcinoma tended to be higher than that of small cell carcinoma in the two groups. The possibility of lung cancer in patients with pulmonary nodule, coexisting emphysema, and especially in elderly patients having a history of smoking must be clarified on HRCT

  1. Weight of evidence analysis of lung cancer in Colorado Plateau uranium miners

    International Nuclear Information System (INIS)

    Groeer, P.G.; Wallace, P.W.; Pereira, A. de B.

    1989-01-01

    The authors use a Bayesian contingency table analysis to assess lung cancer in the Colorado plateau uranium miners. This population is studied by Whittemore, Hornung and BEIR-IV, but none of these includes the radiation dose from hard rock mining that about 38% of the miners have accumulated. The analysis uses 'weight of evidence' which Good applied to the analysis of lung cancer many years ago. The analysis indicates that only in those exposed for a long period and at high exposure rates is the weight of evidence positive with a coefficient of variation less than unity that radiation is associated with the lung cancers. The coefficient of variation is a criterion of the significance of the weight of evidence for the association of the radon exposure in the miners with lung cancer. In the subsequent discussion it is suggested that this approach is similar to the probability of causation, which it is not. (author)

  2. Analysis of the HVAC system's sound quality using the design of experiments

    International Nuclear Information System (INIS)

    Park, Sang Gil; Sim, Hyun Jin; Yoon, Ji Hyun; Jeong, Jae Eun; Choi, Byoung Jae; Oh, Jae Eung

    2009-01-01

    Human hearing is very sensitive to sound, so a subjective index of sound quality is required. Each situation of sound evaluation is composed of Sound Quality (SQ) metrics. When substituting the level of one frequency band, we could not see the tendency of substitution at the whole frequency band during SQ evaluation. In this study, the Design of Experiments (DOE) is used to analyze noise from an automotive Heating, Ventilating, and Air Conditioning (HVAC) system. The frequency domain is divided into 12 equal parts, and each level of the domain is given an increase or decrease due to the change in frequency band based on the 'loud' and 'sharp' sound of the SQ analyzed. By using DOE, the number of tests is effectively reduced by the number of experiments, and the main result is a solution at each band. SQ in terms of the 'loud' and 'sharp' sound at each band, the change in band (increase or decrease in sound pressure) or no change in band will have the most effect on the identifiable characteristics of SQ. This will enable us to select the objective frequency band. Through the results obtained, the physical level changes in arbitrary frequency domain sensitivity can be determined

  3. General analytical approach for sound transmission loss analysis through a thick metamaterial plate

    International Nuclear Information System (INIS)

    Oudich, Mourad; Zhou, Xiaoming; Badreddine Assouar, M.

    2014-01-01

    We report theoretically and numerically on the sound transmission loss performance through a thick plate-type acoustic metamaterial made of spring-mass resonators attached to the surface of a homogeneous elastic plate. Two general analytical approaches based on plane wave expansion were developed to calculate both the sound transmission loss through the metamaterial plate (thick and thin) and its band structure. The first one can be applied to thick plate systems to study the sound transmission for any normal or oblique incident sound pressure. The second approach gives the metamaterial dispersion behavior to describe the vibrational motions of the plate, which helps to understand the physics behind sound radiation through air by the structure. Computed results show that high sound transmission loss up to 72 dB at 2 kHz is reached with a thick metamaterial plate while only 23 dB can be obtained for a simple homogeneous plate with the same thickness. Such plate-type acoustic metamaterial can be a very effective solution for high performance sound insulation and structural vibration shielding in the very low-frequency range

  4. General analytical approach for sound transmission loss analysis through a thick metamaterial plate

    Energy Technology Data Exchange (ETDEWEB)

    Oudich, Mourad; Zhou, Xiaoming; Badreddine Assouar, M., E-mail: Badreddine.Assouar@univ-lorraine.fr [CNRS, Institut Jean Lamour, Vandoeuvre-lès-Nancy F-54506 (France); Institut Jean Lamour, University of Lorraine, Boulevard des Aiguillettes, BP: 70239, 54506 Vandoeuvre-lès-Nancy (France)

    2014-11-21

    We report theoretically and numerically on the sound transmission loss performance through a thick plate-type acoustic metamaterial made of spring-mass resonators attached to the surface of a homogeneous elastic plate. Two general analytical approaches based on plane wave expansion were developed to calculate both the sound transmission loss through the metamaterial plate (thick and thin) and its band structure. The first one can be applied to thick plate systems to study the sound transmission for any normal or oblique incident sound pressure. The second approach gives the metamaterial dispersion behavior to describe the vibrational motions of the plate, which helps to understand the physics behind sound radiation through air by the structure. Computed results show that high sound transmission loss up to 72 dB at 2 kHz is reached with a thick metamaterial plate while only 23 dB can be obtained for a simple homogeneous plate with the same thickness. Such plate-type acoustic metamaterial can be a very effective solution for high performance sound insulation and structural vibration shielding in the very low-frequency range.

  5. Analysis, Design and Implementation of an Embedded Realtime Sound Source Localization System Based on Beamforming Theory

    Directory of Open Access Journals (Sweden)

    Arko Djajadi

    2009-12-01

    Full Text Available This project is intended to analyze, design and implement a realtime sound source localization system by using a mobile robot as the media. The implementated system uses 2 microphones as the sensors, Arduino Duemilanove microcontroller system with ATMega328p as the microprocessor, two permanent magnet DC motors as the actuators for the mobile robot and a servo motor as the actuator to rotate the webcam directing to the location of the sound source, and a laptop/PC as the simulation and display media. In order to achieve the objective of finding the position of a specific sound source, beamforming theory is applied to the system. Once the location of the sound source is detected and determined, the choice is either the mobile robot will adjust its position according to the direction of the sound source or only webcam will rotate in the direction of the incoming sound simulating the use of this system in a video conference. The integrated system has been tested and the results show the system could localize in realtime a sound source placed randomly on a half circle area (0 - 1800 with a radius of 0.3m - 3m, assuming the system is the center point of the circle. Due to low ADC and processor speed, achievable best angular resolution is still limited to 25o.

  6. Numerical Analysis of Indoor Sound Quality Evaluation Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Yu-Tuan Chou

    2013-01-01

    Full Text Available Indoors sound field distribution is important to Room Acoustics, but the field suffers numerous problems, for example, multipath propagation and scattering owing to sound absorption by furniture and other aspects of décor. Generally, an ideal interior space must have a sound field with clear quality. This provides both the speaker and the listener with a pleasant conversational environment. This investigation uses the Finite Element Method to assess the acoustic distribution based on the indoor space and chamber volume. In this situation, a fixed sound source at different frequencies is used to simulate the acoustic characteristics of the indoor space. This method considers the furniture and decoration sound absorbing material and thus different sound absorption coefficients and configurations. The preliminary numerical simulation provides a method that can forecast the distribution of sound in an indoor room in complex situations. Consequently, it is possible to arrange interior furnishings and appliances to optimize acoustic distribution and environmental friendliness. Additionally, the analytical results can also be used to calculate the Reverberation Time and speech intelligibility for specified indoor space.

  7. Imagining Sound

    DEFF Research Database (Denmark)

    Grimshaw, Mark; Garner, Tom Alexander

    2014-01-01

    We make the case in this essay that sound that is imagined is both a perception and as much a sound as that perceived through external stimulation. To argue this, we look at the evidence from auditory science, neuroscience, and philosophy, briefly present some new conceptual thinking on sound...... that accounts for this view, and then use this to look at what the future might hold in the context of imagining sound and developing technology....

  8. Causes of death in long-term lung cancer survivors: a SEER database analysis.

    Science.gov (United States)

    Abdel-Rahman, Omar

    2017-07-01

    Long-term (>5 years) lung cancer survivors represent a small but distinct subgroup of lung cancer patients and information about the causes of death of this subgroup is scarce. The Surveillance, Epidemiology and End Results (SEER) database (1988-2008) was utilized to determine the causes of death of long-term survivors of lung cancer. Survival analysis was conducted using Kaplan-Meier analysis and multivariate analysis was conducted using a Cox proportional hazard model. Clinicopathological characteristics and survival outcomes were assessed for the whole cohort. A total of 78,701 lung cancer patients with >5 years survival were identified. This cohort included 54,488 patients surviving 5-10 years and 24,213 patients surviving >10 years. Among patients surviving 5-10 years, 21.8% were dead because of primary lung cancer, 10.2% were dead because of other cancers, 6.8% were dead because of cardiac disease and 5.3% were dead because of non-malignant pulmonary disease. Among patients surviving >10 years, 12% were dead because of primary lung cancer, 6% were dead because of other cancers, 6.9% were dead because of cardiac disease and 5.6% were dead because of non-malignant pulmonary disease. On multivariate analysis, factors associated with longer cardiac-disease-specific survival in multivariate analysis include younger age at diagnosis (p death from primary lung cancer is still significant among other causes of death even 20 years after diagnosis of lung cancer. Moreover, cardiac as well as non-malignant pulmonary causes contribute a considerable proportion of deaths in long-term lung cancer survivors.

  9. Elemental analysis of occupational and environmental lung diseases by electron probe microanalyzer with wavelength dispersive spectrometer.

    Science.gov (United States)

    Takada, Toshinori; Moriyama, Hiroshi; Suzuki, Eiichi

    2014-01-01

    Occupational and environmental lung diseases are a group of pulmonary disorders caused by inhalation of harmful particles, mists, vapors or gases. Mineralogical analysis is not generally required in the diagnosis of most cases of these diseases. Apart from minerals that are encountered rarely or only in specific occupations, small quantities of mineral dusts are present in the healthy lung. As such when mineralogical analysis is required, quantitative or semi-quantitative methods must be employed. An electron probe microanalyzer with wavelength dispersive spectrometer (EPMA-WDS) enables analysis of human lung tissue for deposits of elements by both qualitative and semi-quantitative methods. Since 1993, we have analyzed 162 cases of suspected occupational and environmental lung diseases using an EPMA-WDS. Our institute has been accepting online requests for elemental analysis of lung tissue samples by EPMA-WDS since January 2011. Hard metal lung disease is an occupational interstitial lung disease that primarily affects workers exposed to the dust of tungsten carbide. The characteristic pathological findings of the disease are giant cell interstitial pneumonia (GIP) with centrilobular fibrosis, surrounded by mild alveolitis with giant cells within the alveolar space. EPMA-WDS analysis of biopsied lung tissue from patients with GIP has demonstrated that tungsten and/or cobalt is distributed in the giant cells and centrilobular fibrosing lesion in GIP. Pneumoconiosis, caused by amorphous silica, and acute interstitial pneumonia, associated with the giant tsunami, were also elementally analyzed by EPMA-WDS. The results suggest that commonly found elements, such as silicon, aluminum, and iron, may cause occupational and environmental lung diseases. Copyright © 2013 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  10. Development of a Prognostic Marker for Lung Cancer Using Analysis of Tumor Evolution

    Science.gov (United States)

    2017-08-01

    AWARD NUMBER: W81XWH-15-1-0243 TITLE: Development of a Prognostic Marker for Lung Cancer Using Analysis of Tumor Evolution PRINCIPAL...SUBTITLE 5a. CONTRACT NUMBER Development of a Prognostic Marker for Lung Cancer Using Analysis of Tumor Evolution 5b. GRANT NUMBER 5c. PROGRAM...derive a prognostic classifier. 15. SUBJECT TERMS NSCLC; tumor evolution ; whole exome sequencing 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF

  11. Identification of Mobile Phone and Analysis of Original Version of Videos through a Delay Time Analysis of Sound Signals from Mobile Phone Videos.

    Science.gov (United States)

    Hwang, Min Gu; Har, Dong Hwan

    2017-11-01

    This study designs a method of identifying the camera model used to take videos that are distributed through mobile phones and determines the original version of the mobile phone video for use as legal evidence. For this analysis, an experiment was conducted to find the unique characteristics of each mobile phone. The videos recorded by mobile phones were analyzed to establish the delay time of sound signals, and the differences between the delay times of sound signals for different mobile phones were traced by classifying their characteristics. Furthermore, the sound input signals for mobile phone videos used as legal evidence were analyzed to ascertain whether they have the unique characteristics of the original version. The objective of this study was to find a method for validating the use of mobile phone videos as legal evidence using mobile phones through differences in the delay times of sound input signals. © 2017 American Academy of Forensic Sciences.

  12. [Analysis of the heart sound with arrhythmia based on nonlinear chaos theory].

    Science.gov (United States)

    Ding, Xiaorong; Guo, Xingming; Zhong, Lisha; Xiao, Shouzhong

    2012-10-01

    In this paper, a new method based on the nonlinear chaos theory was proposed to study the arrhythmia with the combination of the correlation dimension and largest Lyapunov exponent, through computing and analyzing these two parameters of 30 cases normal heart sound and 30 cases with arrhythmia. The results showed that the two parameters of the heart sounds with arrhythmia were higher than those with the normal, and there was significant difference between these two kinds of heart sounds. That is probably due to the irregularity of the arrhythmia which causes the decrease of predictability, and it's more complex than the normal heart sound. Therefore, the correlation dimension and the largest Lyapunov exponent can be used to analyze the arrhythmia and for its feature extraction.

  13. Analysis of In Situ Thermal Ion Measurements from the MICA Sounding Rocket

    Science.gov (United States)

    Fernandes, P. A.; Lynch, K. A.; Zettergren, M. D.; Hampton, D. L.; Fisher, L. E.; Powell, S. P.

    2014-12-01

    The MICA sounding rocket launched on 19 Feb. 2012 into several discrete, localized arcs in the wake of a westward traveling surge. In situ and ground-based observations provide a measured response of the ionosphere to preflight and localized auroral drivers. Initial analysis of the in situ thermal ion data indicate possible measurement of an ion conic at low altitude (< 325 km). In the low-energy regime, the response of the instrument varies from the ideal because the measured thermal ion population is sensitive to the presence of the instrument. The plasma is accelerated in the frame of the instrument due to flows, ram, and acceleration through the sheath which forms around the spacecraft. The energies associated with these processes are large compared to the thermal energy. Correct interpretation of thermal plasma measurements requires accounting for all of these plasma processes and the non-ideal response of the instrument in the low-energy regime. This is an experimental and modeling project which involves thorough analysis of ionospheric thermal ion data from the MICA campaign. Analysis includes modeling and measuring the instrument response in the low-energy regime as well as accounting for the complex sheath formed around the instrument. This results in a forward model in which plasma parameters of the thermal plasma are propagated through the sheath and instrument models, resulting in an output which matches the in situ measurement. In the case of MICA, we are working toward answering the question of the initiating source processes that result, at higher altitudes, in well-developed conics and outflow on auroral field lines.

  14. The risk of lung cancer among cooking adults: a meta-analysis of 23 observational studies.

    Science.gov (United States)

    Jia, Peng-Li; Zhang, Chao; Yu, Jia-Jie; Xu, Chang; Tang, Li; Sun, Xin

    2018-02-01

    Cooking has been regarded as a potential risk factor for lung cancer. We aim to investigate the evidence of cooking oil fume and risk of lung cancer. Medline and Embase were searched for eligible studies. We conducted a meta-analysis to summarize the evidences of case-control or cohort studies, with subgroup analysis for the potential discrepancy. Sensitivity analysis was employed to test the robustness. We included 23 observational studies, involving 9411 lung cancer cases. Our meta-analysis found that, for cooking female, the pooled OR of cooking oil fume exposure was 1.98 (95% CI 1.54, 2.54, I 2  = 79%, n = 15) among non-smoking population and 2.00 (95% CI 1.46, 2.74, I 2  = 75%, n = 10) among partly smoking population. For cooking males, the pooled OR of lung cancer was 1.15 (95% CI 0.71, 1.87; I 2  = 80%, n = 4). When sub grouped by ventilation condition, the pooled OR for poor ventilation was 1.20 (95% CI 1.10, 1.31, I 2  = 2%) compared to good ventilation. For different cooking methods, our results suggested that stir frying (OR = 1.89, 95% CI 1.23, 2.90; I 2  = 66%) was associated with increased risk of lung cancer while not for deep frying (OR = 1.41, 95% CI 0.87, 2.29; I 2  = 5%). Sensitivity analysis suggested our results were stable. Cooking oil fume is likely to be a risk factor for lung cancer for female, regardless of smoking status. Poor ventilation may increase the risk of lung cancer. Cooking methods may have different effect on lung cancer that deep frying may be healthier than stir frying.

  15. Analysis of sound absorption performance of an electroacoustic absorber using a vented enclosure

    Science.gov (United States)

    Cho, Youngeun; Wang, Semyung; Hyun, Jaeyub; Oh, Seungjae; Goo, Seongyeol

    2018-03-01

    The sound absorption performance of an electroacoustic absorber (EA) is primarily influenced by the dynamic characteristics of the loudspeaker that acts as the actuator of the EA system. Therefore, the sound absorption performance of the EA is maximum at the resonance frequency of the loudspeaker and tends to degrade in the low-frequency and high-frequency bands based on this resonance frequency. In this study, to adjust the sound absorption performance of the EA system in the low-frequency band of approximately 20-80 Hz, an EA system using a vented enclosure that has previously been used to enhance the radiating sound pressure of a loudspeaker in the low-frequency band, is proposed. To verify the usefulness of the proposed system, two acoustic environments are considered. In the first acoustic environment, the vent of the vented enclosure is connected to an external sound field that is distinct from the sound field coupled to the EA. In this case, the acoustic effect of the vented enclosure on the performance of the EA is analyzed through an analytical approach using dynamic equations and an impedance-based equivalent circuit. Then, it is verified through numerical and experimental approaches. Next, in the second acoustic environment, the vent is connected to the same external sound field as the EA. In this case, the effect of the vented enclosure on the EA is investigated through an analytical approach and finally verified through a numerical approach. As a result, it is confirmed that the characteristics of the sound absorption performances of the proposed EA system using the vented enclosure in the two acoustic environments considered in this study are different from each other in the low-frequency band of approximately 20-80 Hz. Furthermore, several case studies on the change tendency of the performance of the EA using the vented enclosure according to the critical design factors or vent number for the vented enclosure are also investigated. In the future

  16. Sound knowledge

    DEFF Research Database (Denmark)

    Kauffmann, Lene Teglhus

    as knowledge based on reflexive practices. I chose ‘health promotion’ as the field for my research as it utilises knowledge produced in several research disciplines, among these both quantitative and qualitative. I mapped out the institutions, actors, events, and documents that constituted the field of health...... of the research is to investigate what is considered to ‘work as evidence’ in health promotion and how the ‘evidence discourse’ influences social practices in policymaking and in research. From investigating knowledge practices in the field of health promotion, I develop the concept of sound knowledge...... result of a rigorous and standardized research method. However, this anthropological analysis shows that evidence and evidence-based is a hegemonic ‘way of knowing’ that sometimes transposes everyday reasoning into an epistemological form. However, the empirical material shows a variety of understandings...

  17. The diagnostics of a nuclear reactor by the analysis of boiling sound

    International Nuclear Information System (INIS)

    Kudo, Kazuhiko; Tanaka, Yoshihisa; Ohsawa, Takaaki; Ohta, Masao

    1980-01-01

    This paper is described on the basic research concerning the method of detecting abnormality by analyzing boiling sound when the heat transfer to coolant became locally abnormal in a pressurized nuclear reactor. In this study, the power spectra of sound were grasped as a sort of pattern, and it was aimed at to diagnose exactly the state in a reactor by analyzing the change with an electronic computer. As the calculating method, the theory of linear distinction function was applied. The subcritical experimental apparatus was used as a simulated reactor core vessel, and boiling sound was received with a hydrophone, amplified, digitalized and processed with a computer. The power spectra of boiling sound were displayed on an oscilloscope, and the digital values were stored in a micro-computer. The method of calculating treatment of the power spectra stored as the data in the microcomputer is explained. The magnitude of the power spectra was large in low frequency region, and decreased as the frequency became higher. The experimental conditions and the results are described. According to the results, considerably good distinction capability was obtained. By utilizing the power spectra in relatively low frequency region, the detection of boiling sound can be made with considerably high accuracy. (Kako, I.)

  18. ABOUT SOUNDS IN VIDEO GAMES

    Directory of Open Access Journals (Sweden)

    Denikin Anton A.

    2012-12-01

    Full Text Available The article considers the aesthetical and practical possibilities for sounds (sound design in video games and interactive applications. Outlines the key features of the game sound, such as simulation, representativeness, interactivity, immersion, randomization, and audio-visuality. The author defines the basic terminology in study of game audio, as well as identifies significant aesthetic differences between film sounds and sounds in video game projects. It is an attempt to determine the techniques of art analysis for the approaches in study of video games including aesthetics of their sounds. The article offers a range of research methods, considering the video game scoring as a contemporary creative practice.

  19. Prognostic value of the neutrophil to lymphocyte ratio in lung cancer: A meta-analysis.

    Science.gov (United States)

    Yin, Yongmei; Wang, Jun; Wang, Xuedong; Gu, Lan; Pei, Hao; Kuai, Shougang; Zhang, Yingying; Shang, Zhongbo

    2015-07-01

    Recently, a series of studies explored the correlation between the neutrophil to lymphocyte ratio and the prognosis of lung cancer. However, the current opinion regarding the prognostic role of the neutrophil to lymphocyte ratio in lung cancer is inconsistent. We performed a meta-analysis of published articles to investigate the prognostic value of the neutrophil to lymphocyte ratio in lung cancer. The hazard ratio (HR) and its 95% confidence interval (CI) were calculated. An elevated neutrophil to lymphocyte ratio predicted worse overall survival, with a pooled HR of 1.243 (95%CI: 1.106-1.397; P(heterogeneity)=0.001) from multivariate studies and 1.867 (95%CI: 1.487-2.344; P(heterogeneity)=0.047) from univariate studies. Subgroup analysis showed that a high neutrophil to lymphocyte ratio yielded worse overall survival in non-small cell lung cancer (NSCLC) (HR=1.192, 95%CI: 1.061-1.399; P(heterogeneity)=0.003) as well as small cell lung cancer (SCLC) (HR=1.550, 95% CI: 1.156-2.077; P(heterogeneity)=0.625) in multivariate studies. The synthesized evidence from this meta-analysis of published articles demonstrated that an elevated neutrophil to lymphocyte ratio was a predictor of poor overall survival in patients with lung cancer.

  20. Exposure to secondhand tobacco smoke and lung cancer by histological type: a pooled analysis of the International Lung Cancer Consortium (ILCCO)

    Science.gov (United States)

    Kim, Claire H; Lee, Yuan-Chin Amy; Hung, Rayjean J; McNallan, Sheila R; Cote, Michele L; Lim, Wei-Yen; Chang, Shen-Chih; Kim, Jin Hee; Ugolini, Donatella; Chen, Ying; Liloglou, Triantafillos; Andrew, Angeline S; Onega, Tracy; Duell, Eric J; Field, John K; Lazarus, Philip; Le Marchand, Loic; Neri, Monica; Vineis, Paolo; Kiyohara, Chikako; Hong, Yun-Chul; Morgenstern, Hal; Matsuo, Keitaro; Tajima, Kazuo; Christiani, David C; McLaughlin, John R; Bencko, Vladimir; Holcatova, Ivana; Boffetta, Paolo; Brennan, Paul; Fabianova, Eleonora; Foretova, Lenka; Janout, Vladimir; Lissowska, Jolanta; Mates, Dana; Rudnai, Peter; Szeszenia-Dabrowska, Neonila; Mukeria, Anush; Zaridze, David; Seow, Adeline; Schwartz, Ann G; Yang, Ping; Zhang, Zuo-Feng

    2014-01-01

    While the association between exposure to secondhand smoke and lung cancer risk is well established, few studies with sufficient power have examined the association by histological type. In this study, we evaluated the secondhand smoke-lung cancer relationship by histological type based on pooled data from 18 case-control studies in the International Lung Cancer Consortium (ILCCO), including 2,504 cases and 7,276 controls who were never smokers and 10,184 cases and 7,176 controls who were ever smokers. We used multivariable logistic regression, adjusting for age, sex, race/ethnicity, smoking status, pack-years of smoking, and study. Among never smokers, the odds ratios (OR) comparing those ever exposed to secondhand smoke with those never exposed were 1.31 (95% CI: 1.17–1.45) for all histological types combined, 1.26 (95% CI: 1.10–1.44) for adenocarcinoma, 1.41 (95% CI: 0.99–1.99) for squamous cell carcinoma, 1.48 (95% CI: 0.89–2.45) for large cell lung cancer, and 3.09 (95% CI: 1.62–5.89) for small cell lung cancer. The estimated association with secondhand smoke exposure was greater for small cell lung cancer than for non-small cell lung cancers (OR=2.11, 95% CI: 1.11–4.04). This analysis is the largest to date investigating the relation between exposure to secondhand smoke and lung cancer. Our study provides more precise estimates of the impact of secondhand smoke on the major histological types of lung cancer, indicates the association with secondhand smoke is stronger for small cell lung cancer than for the other histological types, and suggests the importance of intervention against exposure to secondhand smoke in lung cancer prevention. PMID:24615328

  1. Exposure to secondhand tobacco smoke and lung cancer by histological type: a pooled analysis of the International Lung Cancer Consortium (ILCCO).

    Science.gov (United States)

    Kim, Claire H; Lee, Yuan-Chin Amy; Hung, Rayjean J; McNallan, Sheila R; Cote, Michele L; Lim, Wei-Yen; Chang, Shen-Chih; Kim, Jin Hee; Ugolini, Donatella; Chen, Ying; Liloglou, Triantafillos; Andrew, Angeline S; Onega, Tracy; Duell, Eric J; Field, John K; Lazarus, Philip; Le Marchand, Loic; Neri, Monica; Vineis, Paolo; Kiyohara, Chikako; Hong, Yun-Chul; Morgenstern, Hal; Matsuo, Keitaro; Tajima, Kazuo; Christiani, David C; McLaughlin, John R; Bencko, Vladimir; Holcatova, Ivana; Boffetta, Paolo; Brennan, Paul; Fabianova, Eleonora; Foretova, Lenka; Janout, Vladimir; Lissowska, Jolanta; Mates, Dana; Rudnai, Peter; Szeszenia-Dabrowska, Neonila; Mukeria, Anush; Zaridze, David; Seow, Adeline; Schwartz, Ann G; Yang, Ping; Zhang, Zuo-Feng

    2014-10-15

    While the association between exposure to secondhand smoke and lung cancer risk is well established, few studies with sufficient power have examined the association by histological type. In this study, we evaluated the secondhand smoke-lung cancer relationship by histological type based on pooled data from 18 case-control studies in the International Lung Cancer Consortium (ILCCO), including 2,504 cases and 7,276 control who were never smokers and 10,184 cases and 7,176 controls who were ever smokers. We used multivariable logistic regression, adjusting for age, sex, race/ethnicity, smoking status, pack-years of smoking, and study. Among never smokers, the odds ratios (OR) comparing those ever exposed to secondhand smoke with those never exposed were 1.31 (95% CI: 1.17-1.45) for all histological types combined, 1.26 (95% CI: 1.10-1.44) for adenocarcinoma, 1.41 (95% CI: 0.99-1.99) for squamous cell carcinoma, 1.48 (95% CI: 0.89-2.45) for large cell lung cancer, and 3.09 (95% CI: 1.62-5.89) for small cell lung cancer. The estimated association with secondhand smoke exposure was greater for small cell lung cancer than for nonsmall cell lung cancers (OR=2.11, 95% CI: 1.11-4.04). This analysis is the largest to date investigating the relation between exposure to secondhand smoke and lung cancer. Our study provides more precise estimates of the impact of secondhand smoke on the major histological types of lung cancer, indicates the association with secondhand smoke is stronger for small cell lung cancer than for the other histological types, and suggests the importance of intervention against exposure to secondhand smoke in lung cancer prevention. © 2014 UICC.

  2. Unsound Sound

    DEFF Research Database (Denmark)

    Knakkergaard, Martin

    2016-01-01

    This article discusses the change in premise that digitally produced sound brings about and how digital technologies more generally have changed our relationship to the musical artifact, not simply in degree but in kind. It demonstrates how our acoustical conceptions are thoroughly challenged...... by the digital production of sound and, by questioning the ontological basis for digital sound, turns our understanding of the core term substance upside down....

  3. A CROSS-COUNTRY ANALYSIS OF THE BANKS’ FINANCIAL SOUNDNESS: THE CASE OF THE CEE-3 COUNTRIES

    Directory of Open Access Journals (Sweden)

    Sargu Alina Camelia

    2013-07-01

    Full Text Available The European integration process has a direct impact on all the components of the macroeconomic environment. The existence of a well functioning and sound banking sector becomes of great importance for the integration process as the European Union economy is financed especially through this channel. The banking sectors of the new EU member countries have undergone through tremendous changes in the last decade, both from an ownership and also from a business strategy point of view, these changes having a direct impact on their financial soundness. Thus, the aim of our research is to empirically examine the financial soundness of the banks operating in Bulgaria, Czech Republic and Romania, three EU members countries from Central and Eastern Europe (CEE-3. In order to achieve this we have employed a combine quantitative analysis based on the CAMELS framework (namely Capital Adequacy, Asset quality, Management soundness, Earnings, Liquidity, Sensitivity to market risk and the Z-score, thus being able to underline simultaneously the financial soundness and the possibility of default for the banks from our sample. The analysed period is 2004-2011 providing us with an evaluation of the impact that the EU ascension and also the global financial crisis had on the financial soundness of the analysed banks. Our sample is composed from 40 commercial banks that operate in Bulgaria, the Czech Republic and Romania, that overall own over 75% of the total banking assets, making this study one of the most comprehensive undertaken to this date. The data that we have employed in our research is obtained from the Bureau Van Dijk Bankscope database and the annual financial statements of the banks from our sample. The paper through its original dual approach contributes to the academic debate by providing not only insight into the financial soundness of the banks operating in the CEE-3 countries but also underling their financial strength through the usage of the Z

  4. Automatic moment segmentation and peak detection analysis of heart sound pattern via short-time modified Hilbert transform.

    Science.gov (United States)

    Sun, Shuping; Jiang, Zhongwei; Wang, Haibin; Fang, Yu

    2014-05-01

    This paper proposes a novel automatic method for the moment segmentation and peak detection analysis of heart sound (HS) pattern, with special attention to the characteristics of the envelopes of HS and considering the properties of the Hilbert transform (HT). The moment segmentation and peak location are accomplished in two steps. First, by applying the Viola integral waveform method in the time domain, the envelope (E(T)) of the HS signal is obtained with an emphasis on the first heart sound (S1) and the second heart sound (S2). Then, based on the characteristics of the E(T) and the properties of the HT of the convex and concave functions, a novel method, the short-time modified Hilbert transform (STMHT), is proposed to automatically locate the moment segmentation and peak points for the HS by the zero crossing points of the STMHT. A fast algorithm for calculating the STMHT of E(T) can be expressed by multiplying the E(T) by an equivalent window (W(E)). According to the range of heart beats and based on the numerical experiments and the important parameters of the STMHT, a moving window width of N=1s is validated for locating the moment segmentation and peak points for HS. The proposed moment segmentation and peak location procedure method is validated by sounds from Michigan HS database and sounds from clinical heart diseases, such as a ventricular septal defect (VSD), an aortic septal defect (ASD), Tetralogy of Fallot (TOF), rheumatic heart disease (RHD), and so on. As a result, for the sounds where S2 can be separated from S1, the average accuracies achieved for the peak of S1 (AP₁), the peak of S2 (AP₂), the moment segmentation points from S1 to S2 (AT₁₂) and the cardiac cycle (ACC) are 98.53%, 98.31% and 98.36% and 97.37%, respectively. For the sounds where S1 cannot be separated from S2, the average accuracies achieved for the peak of S1 and S2 (AP₁₂) and the cardiac cycle ACC are 100% and 96.69%. Copyright © 2014 Elsevier Ireland Ltd. All

  5. Association of XPC polymorphisms and lung cancer risk: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Bo Jin

    Full Text Available BACKGROUND: Xeroderma pigmentosum complementation group C gene (XPC is a key member of nucleotide excision repair pathway and plays an important role in human DNA repair system. It is reported that several common polymorphisms of XPC are associated with susceptibility to lung cancer. However, the conclusion is still elusive. METHOD: This meta-analysis was performed to determine the relationship between XPC polymorphisms (Lys939Gln, Ala499Val, and PAT and lung cancer risk. Published literatures were identified by searching online databases and reference lists of relevant studies. Odds ratios (ORs and 95% confidence intervals (CIs were calculated to estimate the association strength. Publication bias were detected by Egger's and Begg's test. RESULT: After strict screening, we identified 14 eligible studies in this meta-analysis, including 5647 lung cancer cases and 6908 controls. By pooling all eligible studies, we found that the homozygote Gln939Gln genotype was associated with a significantly increased risk of lung cancer in Asian population (GlnGln vs LysLys, OR=1.229, 95% CI: 1.000-1.510; GlnGln vs LysLys/LysGln, OR=1.257, 95% CI: 1.038-1.522. As for the PAT polymorphism, in Caucasian population, we found carriers of the -/- genotype were associated significantly reduced risk of lung cancer in homozygote comparison model (-/- vs +/+, OR=0.735, 95% CI: 0.567-0.952. CONCLUSION: In this meta-analysis we found that Gln939Gln genotype was associated with significantly increased risk of lung cancer in Asian population; the PAT -/- genotype significantly reduced susceptibility to lung cancer in Caucasian population; while the XPC Ala499Val polymorphism was not associated with lung cancer risk.

  6. Sound Absorbers

    Science.gov (United States)

    Fuchs, H. V.; Möser, M.

    Sound absorption indicates the transformation of sound energy into heat. It is, for instance, employed to design the acoustics in rooms. The noise emitted by machinery and plants shall be reduced before arriving at a workplace; auditoria such as lecture rooms or concert halls require a certain reverberation time. Such design goals are realised by installing absorbing components at the walls with well-defined absorption characteristics, which are adjusted for corresponding demands. Sound absorbers also play an important role in acoustic capsules, ducts and screens to avoid sound immission from noise intensive environments into the neighbourhood.

  7. CYP1A1 Ile462Val polymorphism contributes to lung cancer susceptibility among lung squamous carcinoma and smokers: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Ya-Nan Ji

    Full Text Available Many studies have examined the association between the CYP1A1 Ile462Val gene polymorphisms and lung cancer risk in various populations, but their results have been inconsistent. To assess this relationship more precisely, a meta-analysis was performed. Ultimately, 43 case-control studies, comprising 19,228 subjects were included. A significantly elevated lung cancer risk was associated with 2 Ile462Val genotype variants (for Val/Val vs Ile/Ile: OR = 1.22, 95% CI = 1.08-1.40; for (Ile/Val +Val/Val vs Ile/Ile: OR = 1.15, 95% CI = 1.07-1.23 in overall population. In the stratified analysis, a significant association was found in Asians, Caucasians and lung SCC, not lung AC and lung SCLC. Additionally, a significant association was found in smoker population and not found in non-smoker populations. This meta-analysis suggests that the Ile462Val polymorphisms of CYP1A1 correlate with increased lung cancer susceptibility in Asian and Caucasian populations and there is an interaction with smoking status, but these associations vary in different histological types of lung caner.

  8. Surface return direction-of-arrival analysis for radar ice sounding surface clutter suppression

    DEFF Research Database (Denmark)

    Nielsen, Ulrik; Dall, Jørgen

    2015-01-01

    Airborne radar ice sounding is challenged by surface clutter masking the depth signal of interest. Surface clutter may even be prohibitive for potential space-based ice sounding radars. To some extent the radar antenna suppresses the surface clutter, and a multi-phase-center antenna in combination...... with coherent signal processing techniques can improve the suppression, in particular if the direction of arrival (DOA) of the clutter signal is estimated accurately. This paper deals with data-driven DOA estimation. By using P-band data from the ice shelf in Antarctica it is demonstrated that a varying...

  9. Crowing Sound Analysis of Gaga' Chicken; Local Chicken from South Sulawesi Indonesia

    OpenAIRE

    Aprilita Bugiwati, Sri Rachma; Ashari, Fachri

    2008-01-01

    Gaga??? chicken was known as a local chicken at South Sulawesi Indonesia which has unique, specific, and different crowing sound, especially at the ending of crowing sound which is like the voice character of human laughing, comparing with the other types of singing chicken in the world. 287 birds of Gaga??? chicken at 3 districts at the centre habitat of Gaga??? chicken were separated into 2 groups (163 birds of Dangdut type and 124 birds of Slow type) which is based on the speed...

  10. Vibration analysis and sound field characteristics of a tubular ultrasonic radiator.

    Science.gov (United States)

    Liang, Zhaofeng; Zhou, Guangping; Zhang, Yihui; Li, Zhengzhong; Lin, Shuyu

    2006-12-01

    A sort of tubular ultrasonic radiator used in ultrasonic liquid processing is studied. The frequency equation of the tubular radiator is derived, and its radiated sound field in cylindrical reactor is calculated using finite element method and recorded by means of aluminum foil erosion. The results indicate that sound field of tubular ultrasonic radiator in cylindrical reactor appears standing waves along both its radial direction and axial direction, and amplitudes of standing waves decrease gradually along its radial direction, and the numbers of standing waves along its axial direction are equal to the axial wave numbers of tubular radiator. The experimental results are in good agreement with calculated results.

  11. [Analysis of 2 patients with occupational hard mental lung disease].

    Science.gov (United States)

    Ding, Bangmei; Ding, Lu; Yu, Bin; Fan, Cunhua; Han, Lei; Hu, Jinmei; Zhu, Baoli

    2015-01-01

    We sought to master the clinical characteristics and prognosis of hard mental lung disease, improving this disease's diagnosis and treatment quality. We recruited two suspected patients with hard mental lung disease and collected their occupational history, examination results of occupational health, and past medical records. By virtue of laboratory tests, high Kv chest radiography, CT and HRCT of chest, fiberoptic bronchoscopy and ECG examination, diagnostic report was synthesized respectively by respiratory physicians and pathologist from three different agencies. Then the report was submitted to diagnosis organizations of occupational disease, and diagnostic conclusion of occupational disease was drawn after discussion by at least three diagnosticians of occupational disease. We found that both of the two suspected patients were exposed to dusts of hard metal, and length of exposure service ranged from 8 to 9 years. Clinical manifestations were dominated by dry cough, wheezing after activities, and pathological manifestation was characteristic giant cell interstitial pneumonia. The prognosis and outcome of the disease were different. According to exact occupational exposure history, clinical manifestations, combined with the results of high Kv chest radiography, CT of chest and pathological manifestation, it can be diagnosed with hard mental lung disease.

  12. Transcriptome Analysis of the Preterm Rabbit Lung after Seven Days of Hyperoxic Exposure.

    Directory of Open Access Journals (Sweden)

    Thomas Salaets

    Full Text Available The neonatal management of preterm born infants often results in damage to the developing lung and subsequent morbidity, referred to as bronchopulmonary dysplasia (BPD. Animal models may help in understanding the molecular processes involved in this condition and define therapeutic targets. Our goal was to identify molecular pathways using the earlier described preterm rabbit model of hyperoxia induced lung-injury. Transcriptome analysis by mRNA-sequencing was performed on lungs from preterm rabbit pups born at day 28 of gestation (term: 31 days and kept in hyperoxia (95% O2 for 7 days. Controls were preterm pups kept in normoxia. Transcriptomic data were analyzed using Array Studio and Ingenuity Pathway Analysis (IPA, in order to identify the central molecules responsible for the observed transcriptional changes. We detected 2217 significantly dysregulated transcripts following hyperoxia, of which 90% could be identified. Major pathophysiological dysregulations were found in inflammation, lung development, vascular development and reactive oxygen species (ROS metabolism. To conclude, amongst the many dysregulated transcripts, major changes were found in the inflammatory, oxidative stress and lung developmental pathways. This information may be used for the generation of new treatment hypotheses for hyperoxia-induced lung injury and BPD.

  13. Periodontal Disease and Incident Lung Cancer Risk: A Meta-Analysis of Cohort Studies.

    Science.gov (United States)

    Zeng, Xian-Tao; Xia, Ling-Yun; Zhang, Yong-Gang; Li, Sheng; Leng, Wei-Dong; Kwong, Joey S W

    2016-10-01

    Periodontal disease is linked to a number of systemic diseases such as cardiovascular diseases and diabetes mellitus. Recent evidence has suggested periodontal disease might be associated with lung cancer. However, their precise relationship is yet to be explored. Hence, this study aims to investigate the association of periodontal disease and risk of incident lung cancer using a meta-analytic approach. PubMed, Scopus, and ScienceDirect were searched up to June 10, 2015. Cohort and nested case-control studies investigating risk of lung cancer in patients with periodontal disease were included. Hazard ratios (HRs) were calculated, as were their 95% confidence intervals (CIs) using a fixed-effect inverse-variance model. Statistical heterogeneity was explored using the Q test as well as the I(2) statistic. Publication bias was assessed by visual inspection of funnel plots symmetry and Egger's test. Five cohort studies were included, involving 321,420 participants in this meta-analysis. Summary estimates based on adjusted data showed that periodontal disease was associated with a significant risk of lung cancer (HR = 1.24, 95% CI = 1.13 to 1.36; I(2) = 30%). No publication bias was detected. Subgroup analysis indicated that the association of periodontal disease and lung cancer remained significant in the female population. Evidence from cohort studies suggests that patients with periodontal disease are at increased risk of developing lung cancer.

  14. Lung Cancer Susceptibility and hOGG1 Ser326Cys Polymorphism: A Meta-Analysis

    International Nuclear Information System (INIS)

    Kiyohara, Chikako; Takayama, Koichi; Nakanishi, Yoichi

    2010-01-01

    Recent lung cancer studies have focused on identifying the effects of single nucleotide polymorphisms (SNPs) in candidate genes, among which DNA repair genes are increasingly being studied. Genetic variations in DNA repair genes are thought to modulate DNA repair capacity and are suggested to be related to lung cancer risk. In this study, we tried to assess reported studies of association between polymorphism of human 8-oxoguanine DNA glycosylase 1 (hOGG1) Ser326Cys and lung cancer. We conducted MEDLINE, Current Contents and Web of Science searches using 'hOGG1', 'lung cancer' and 'polymorphism' as keywords to search for papers published (from January 1995 through August 2010). Data were combined using both a fixed effects (the inverse variance-weighted method) and a random effects (DerSimonian and Laird method) models. The Cochran Q test was used for the assessment of heterogeneity. Publication bias was assessed by both Begg’s and Egger’s tests. We identified 20 case-control studies in 21 different ethnic populations. As two studies were not in the Hardy-Weinberg equilibrium, 18 case-control studies in 19 different ethnic populations (7,792 cases and 9,358 controls) were included in our meta-analysis. Summary frequencies of the Cys allele among Caucasians and Asians based on the random effects model were 20.9% (95% confidence interval (CI) = 18.9–22.9) and 46.1% (95% CI = 40.2–52.0), respectively. The distribution of the Cys allele was significantly different between Asians and Caucasians (P < 0.001). The Cys/Cys genotype was significantly associated with lung cancer risk in Asian populations (odds ratio = 1.27, 95% CI = 1.09–1.48) but not in Caucasian populations. This ethnic difference in lung cancer risk may be due to environmental factors such as cigarette smoking and dietary factors. Although the summary risk for developing lung cancer may not be large, lung cancer is such a common malignancy that even a small increase

  15. Lung Cancer Susceptibility and hOGG1 Ser326Cys Polymorphism: A Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kiyohara, Chikako, E-mail: chikako@phealth.med.kyushu-u.ac.jp [Department of Preventive Medicine, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Takayama, Koichi; Nakanishi, Yoichi [Research Institute for Diseases of the Chest, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2010-10-28

    Recent lung cancer studies have focused on identifying the effects of single nucleotide polymorphisms (SNPs) in candidate genes, among which DNA repair genes are increasingly being studied. Genetic variations in DNA repair genes are thought to modulate DNA repair capacity and are suggested to be related to lung cancer risk. In this study, we tried to assess reported studies of association between polymorphism of human 8-oxoguanine DNA glycosylase 1 (hOGG1) Ser326Cys and lung cancer. We conducted MEDLINE, Current Contents and Web of Science searches using 'hOGG1', 'lung cancer' and 'polymorphism' as keywords to search for papers published (from January 1995 through August 2010). Data were combined using both a fixed effects (the inverse variance-weighted method) and a random effects (DerSimonian and Laird method) models. The Cochran Q test was used for the assessment of heterogeneity. Publication bias was assessed by both Begg’s and Egger’s tests. We identified 20 case-control studies in 21 different ethnic populations. As two studies were not in the Hardy-Weinberg equilibrium, 18 case-control studies in 19 different ethnic populations (7,792 cases and 9,358 controls) were included in our meta-analysis. Summary frequencies of the Cys allele among Caucasians and Asians based on the random effects model were 20.9% (95% confidence interval (CI) = 18.9–22.9) and 46.1% (95% CI = 40.2–52.0), respectively. The distribution of the Cys allele was significantly different between Asians and Caucasians (P < 0.001). The Cys/Cys genotype was significantly associated with lung cancer risk in Asian populations (odds ratio = 1.27, 95% CI = 1.09–1.48) but not in Caucasian populations. This ethnic difference in lung cancer risk may be due to environmental factors such as cigarette smoking and dietary factors. Although the summary risk for developing lung cancer may not be large, lung cancer is such a common malignancy that even a small increase

  16. The Reduction of Vertical Interchannel Crosstalk: The Analysis of Localisation Thresholds for Natural Sound Sources

    Directory of Open Access Journals (Sweden)

    Rory Wallis

    2017-03-01

    Full Text Available In subjective listening tests, natural sound sources were presented to subjects as vertically-oriented phantom images from two layers of loudspeakers, ‘height’ and ‘main’. Subjects were required to reduce the amplitude of the height layer until the position of the resultant sound source matched that of the same source presented from the main layer only (the localisation threshold. Delays of 0, 1 and 10 ms were applied to the height layer with respect to the main, with vertical stereophonic and quadraphonic conditions being tested. The results of the study showed that the localisation thresholds obtained were not significantly affected by sound source or presentation method. Instead, the only variable whose effect was significant was interchannel time difference (ICTD. For ICTD of 0 ms, the median threshold was −9.5 dB, which was significantly lower than the −7 dB found for both 1 and 10 ms. The results of the study have implications both for the recording of sound sources for three-dimensional (3D audio reproduction formats and also for the rendering of 3D images.

  17. Community Response to Multiple Sound Sources: Integrating Acoustic and Contextual Approaches in the Analysis

    Directory of Open Access Journals (Sweden)

    Peter Lercher

    2017-06-01

    Full Text Available Sufficient data refer to the relevant prevalence of sound exposure by mixed traffic sources in many nations. Furthermore, consideration of the potential effects of combined sound exposure is required in legal procedures such as environmental health impact assessments. Nevertheless, current practice still uses single exposure response functions. It is silently assumed that those standard exposure-response curves accommodate also for mixed exposures—although some evidence from experimental and field studies casts doubt on this practice. The ALPNAP-study population (N = 1641 shows sufficient subgroups with combinations of rail-highway, highway-main road and rail-highway-main road sound exposure. In this paper we apply a few suggested approaches of the literature to investigate exposure-response curves and its major determinants in the case of exposure to multiple traffic sources. Highly/moderate annoyance and full scale mean annoyance served as outcome. The results show several limitations of the current approaches. Even facing the inherent methodological limitations (energy equivalent summation of sound, rating of overall annoyance the consideration of main contextual factors jointly occurring with the sources (such as vibration, air pollution or coping activities and judgments of the wider area soundscape increases the variance explanation from up to 8% (bivariate, up to 15% (base adjustments up to 55% (full contextual model. The added predictors vary significantly, depending on the source combination. (e.g., significant vibration effects with main road/railway, not highway. Although no significant interactions were found, the observed additive effects are of public health importance. Especially in the case of a three source exposure situation the overall annoyance is already high at lower levels and the contribution of the acoustic indicators is small compared with the non-acoustic and contextual predictors. Noise mapping needs to go down to

  18. Quantitative computed tomography of lung parenchyma in patients with emphysema: analysis of higher-density lung regions

    Science.gov (United States)

    Lederman, Dror; Leader, Joseph K.; Zheng, Bin; Sciurba, Frank C.; Tan, Jun; Gur, David

    2011-03-01

    Quantitative computed tomography (CT) has been widely used to detect and evaluate the presence (or absence) of emphysema applying the density masks at specific thresholds, e.g., -910 or -950 Hounsfield Unit (HU). However, it has also been observed that subjects with similar density-mask based emphysema scores could have varying lung function, possibly indicating differences of disease severity. To assess this possible discrepancy, we investigated whether density distribution of "viable" lung parenchyma regions with pixel values > -910 HU correlates with lung function. A dataset of 38 subjects, who underwent both pulmonary function testing and CT examinations in a COPD SCCOR study, was assembled. After the lung regions depicted on CT images were automatically segmented by a computerized scheme, we systematically divided the lung parenchyma into different density groups (bins) and computed a number of statistical features (i.e., mean, standard deviation (STD), skewness of the pixel value distributions) in these density bins. We then analyzed the correlations between each feature and lung function. The correlation between diffusion lung capacity (DLCO) and STD of pixel values in the bin of -910HU lung parenchyma and lung function, which indicates that similar to the conventional density mask method, the pixel value distribution features in "viable" lung parenchyma areas may also provide clinically useful information to improve assessments of lung disease severity as measured by lung functional tests.

  19. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2008-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  20. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2010-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  1. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2007-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  2. Modeling and Eigenfrequency Analysis of Sound-Structure Interaction in a Rectangular Enclosure with Finite Element Method

    Directory of Open Access Journals (Sweden)

    Samira Mohamady

    2009-01-01

    Full Text Available Vibration of structures due to external sound is one of the main causes of interior noise in cavities like automobile, aircraft, and rotorcraft, which disturb the comfort of passengers. Accurate modelling of such phenomena is required in eigenfrequency analysis and in designing an active noise control system to reduce the interior noise. In this paper, the effect of periodic noise travelling into a rectangular enclosure is investigated with finite element method (FEM using COMSOL Multiphysics software. The periodic acoustic wave is generated by a point source outside the enclosure and propagated through the enclosure wall and excites an aluminium flexible panel clamped onto the enclosure. The behaviour of the transmission of sound into the cavity is investigated by computing the modal characteristics and the natural frequencies of the cavity. The simulation results are compared with previous analytical and experimental works for validation and an acceptable match between them were obtained.

  3. Short communication. Platform for bee-hives monitoring based on sound analysis. A perpetual warehouse for swarms daily activity

    Energy Technology Data Exchange (ETDEWEB)

    Atauri Mezquida, D.; Llorente Martinez, J.

    2009-07-01

    Bees and beekeeping are suffering a global crisis. Constant information on swarms conditions would be a key to study new diseases like colony collapse disorder and to develop new beekeeping tools to improve the hive management and make it more efficient. A platform for beehives monitoring is presented. It is based on the analysis of the colonies buzz which is registered by a bunch of sensors sending the data to a common database. Data obtained through sound processing shows plenty of patterns and tendency lines related to colonies activities and their conditions. It shows the potential of the sound as a swarm activity gauge. The goal of the platform is the possibility to store information about the swarms activity. The objective is to build a global net of monitored hives covering apiaries with different climates, razes and managements. (Author) 21 refs.

  4. Microbiology specimens obtained at the time of surgical lung biopsy for interstitial lung disease: clinical yield and cost analysis.

    Science.gov (United States)

    Fibla, Juan J; Brunelli, Alessandro; Allen, Mark S; Wigle, Dennis; Shen, Robert; Nichols, Francis; Deschamps, Claude; Cassivi, Stephen D

    2012-01-01

    In efforts to obtain complete results, current practice in surgical lung biopsy (LB) for interstitial lung disease (ILD) recommends sending lung tissue samples for bacterial, mycobacterial, fungal, and viral cultures. This study assesses the value of this practice by evaluating the microbiology findings obtained from LB for ILD and their associated costs. A total of 296 consecutive patients (140 women, 156 men, median age=61 years) underwent LB for ILD from 2002 to 2009. All had lung tissue sent for microbiology examination. Microbiology results and resultant changes in patient management were analyzed retrospectively. A cost analysis was performed based upon nominal hospital charges adjusted on current inflation rates. Cost data included cultures, stains, smears, direct fluorescent antibody studies, and microbiologist consulting fees. As many as 25 patients (8.4%) underwent open LB and 271 (91.6%) underwent thoracoscopic LB. A total of 592 specimens were assessed (range 1-4 per patient). The most common pathologic diagnoses were idiopathic pulmonary fibrosis in 122 (41.2%), cryptogenic organizing pneumonia in 31 (10.5%), and respiratory bronchiolitis ILD in 16 (5.4%). Microbiology testing was negative in 174 patients (58.8%). A total of 118 of 122 (96.7%) positive results were clinically considered to be contaminants and resulted in no change in clinical management. The most common contaminants were Propionibacterium acnes (38 patients; 31%) and Penicillium fungus (16 patients; 13%). In only four patients (1.4%), the organism cultured (Nocardia one, Histoplasma one, and Aspergillus fumigatus two) resulted in a change in clinical management. The cost of microbiology studies per specimen was $984 (€709), with a total cost for the study cohort being $582,000 (€420,000). The yield and impact on clinical management of microbiology specimens from LB for ILD is very low. Its routine use in LB is questionable. We suggest it should be limited to those cases of ILD with

  5. Readability analysis of online resources related to lung cancer.

    Science.gov (United States)

    Weiss, Kathleen D; Vargas, Christina R; Ho, Olivia A; Chuang, Danielle J; Weiss, Jonathan; Lee, Bernard T

    2016-11-01

    Patients seeking health information commonly use the Internet as the first source for material. Studies show that well-informed patients have increased involvement, satisfaction, and healthcare outcomes. As one-third of Americans have only basic or below basic health literacy, the National Institutes of Health and American Medical Association recommend patient-directed health resources be written at a sixth-grade reading level. This study evaluates the readability of commonly accessed online resources on lung cancer. A search for "lung cancer" was performed using Google and Bing, and the top 10 websites were identified. Location services were disabled, and sponsored sites were excluded. Relevant articles (n = 109) with patient-directed content available directly from the main sites were downloaded. Readability was assessed using 10 established methods and analyzed with articles grouped by parent website. The average reading grade level across all sites was 11.2, with a range from 8.8 (New Fog Count) to 12.2 (Simple Measure of Gobbledygook). The average Flesch Reading Ease score was 52, corresponding with fairly difficult to read text. The readability varied when compared by individual website, ranging in grade level from 9.2 to 15.2. Only 10 articles (9%) were written below a sixth-grade level and these tended to discuss simpler topics. Patient-directed online information about lung cancer exceeds the recommended sixth-grade reading level. Readability varies between individual websites, allowing physicians to direct patients according to level of health literacy. Modifications to existing materials can significantly improve readability while maintaining content for patients with low health literacy. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Proximity sounding analysis for derechos and supercells: an assessment of similarities and differences

    Science.gov (United States)

    Doswell, Charles A.; Evans, Jeffry S.

    Proximity soundings (within 2 h and 167 km) of derechos (long-lived, widespread damaging convective windstorms) and supercells have been obtained. More than 65 derechos, accompanied by 115 proximity soundings, are identified during the years 1983 to 1993. The derechos have been divided into categories according to the synoptic situation: strong forcing (SF), weak forcing (WF), and "hybrid" cases (which are neither weakly nor strongly forced). Nearly 100 supercell proximity soundings have been found for the period 1998 to 2001, subdivided into nontornadic and tornadic supercells; tornadic supercells were further subdivided into those producing significant (>F1 rating) tornadoes and weak tornadoes (F0-F1 rating). WF derecho situations typically are characterized by warm, moist soundings with large convective available potential instability (CAPE) and relatively weak vertical wind shear. SF derechos usually have stronger wind shears, and cooler and less moist soundings with lower CAPE than the weakly forced cases. Most derechos exhibit strong storm-relative inflow at low levels. In WF derechos, this is usually the result of rapid convective system movement, whereas in SF derechos, storm-relative inflow at low levels is heavily influenced by relatively strong low-level windspeeds. "Hybrid" cases collectively are similar to an average of the SF and WF cases. Supercells occur in environments that are not all that dissimilar from those that produce SF derechos. It appears that some parameter combining instability and deep layer shear, such as the Energy-Helicity Index (EHI), can help discriminate between tornadic and nontornadic supercell situations. Soundings with significant tornadoes (F2 and greater) typically show high 0-1 km relative humidities, and strong 0-1 km shear. Results suggest it may not be easy to forecast the mode of severe thunderstorm activity (i.e., derecho versus supercell) on any particular day, given conditions that favor severe thunderstorm activity

  7. ENERGY CONSERVATION AND GRAVITY WAVES IN SOUND-PROOF TREATMENTS OF STELLAR INTERIORS. II. LAGRANGIAN CONSTRAINED ANALYSIS

    International Nuclear Information System (INIS)

    Vasil, Geoffrey M.; Lecoanet, Daniel; Brown, Benjamin P.; Zweibel, Ellen G.; Wood, Toby S.

    2013-01-01

    The speed of sound greatly exceeds typical flow velocities in many stellar and planetary interiors. To follow the slow evolution of subsonic motions, various sound-proof models attempt to remove fast acoustic waves while retaining stratified convection and buoyancy dynamics. In astrophysics, anelastic models typically receive the most attention in the class of sound-filtered stratified models. Generally, anelastic models remain valid in nearly adiabatically stratified regions like stellar convection zones, but may break down in strongly sub-adiabatic, stably stratified layers common in stellar radiative zones. However, studying stellar rotation, circulation, and dynamos requires understanding the complex coupling between convection and radiative zones, and this requires robust equations valid in both regimes. Here we extend the analysis of equation sets begun in Brown et al., which studied anelastic models, to two types of pseudo-incompressible models. This class of models has received attention in atmospheric applications, and more recently in studies of white-dwarf supernova progenitors. We demonstrate that one model conserves energy but the other does not. We use Lagrangian variational methods to extend the energy conserving model to a general equation of state, and dub the resulting equation set the generalized pseudo-incompressible (GPI) model. We show that the GPI equations suitably capture low-frequency phenomena in both convection and radiative zones in stars and other stratified systems, and we provide recommendations for converting low-Mach number codes to this equation set

  8. Biological Sampling and Analysis in Sinclair and Dyes Inlets, Washington: Chemical Analyses for 2007 Puget Sound Biota Study

    Energy Technology Data Exchange (ETDEWEB)

    Brandenberger, Jill M.; Suslick, Carolynn R.; Johnston, Robert K.

    2008-10-09

    Evaluating spatial and temporal trends in contaminant residues in Puget Sound fish and macroinvertebrates are the objectives of the Puget Sound Ambient Monitoring Program (PSAMP). In a cooperative effort between the ENVironmental inVESTment group (ENVVEST) and Washington State Department of Fish and Wildlife, additional biota samples were collected during the 2007 PSAMP biota survey and analyzed for chemical residues and stable isotopes of carbon (δ13C) and nitrogen (δ15N). Approximately three specimens of each species collected from Sinclair Inlet, Georgia Basin, and reference locations in Puget Sound were selected for whole body chemical analysis. The muscle tissue of specimens selected for chemical analyses were also analyzed for δ13C and δ15N to provide information on relative trophic level and food sources. This data report summarizes the chemical residues for the 2007 PSAMP fish and macro-invertebrate samples. In addition, six Spiny Dogfish (Squalus acanthias) samples were necropsied to evaluate chemical residue of various parts of the fish (digestive tract, liver, embryo, muscle tissue), as well as, a weight proportional whole body composite (WBWC). Whole organisms were homogenized and analyzed for silver, arsenic, cadmium, chromium, copper, nickel, lead, zinc, mercury, 19 polychlorinated biphenyl (PCB) congeners, PCB homologues, percent moisture, percent lipids, δ13C, and δ15N.

  9. Anglophonic Influence in the Use of Sound Symbolism in Italian Disney Comics: A Corpus-based Analysis

    Directory of Open Access Journals (Sweden)

    Pischedda Pier Simone

    2017-12-01

    Full Text Available This article will explore the linguistic implications of employing and creating sound symbolism (ideophones, onomatopoeia and interjections in Italian Disney comics. It will endeavour to investigate the way sound symbolic forms in both imported Disney US comics and original Italian stories have profoundly influenced the development of Italian sound symbolism in the last century. The diachronic analysis is carried out thanks to the creation of a corpus of ideophones and interjections from 210 Disney stories published between 1932 and 2013. The corpus will allow the author to investigate how these forms have changed diachronically throughout the eighty years under investigation with the final aim of highlighting changes and patterns in both original and translated Italian stories. The unique status of ideophones, confirmed by language, sociological and neurological studies, has led to interesting experimentations but also to complicated dynamics. Certain linguistic settings seem to foster a better affinity towards the device- particularly if compared to Romance languages, such as Italian and Spanish, that often have to rely on Anglophone renditions. Anglicisation has indeed overshadowed previous original attempts. Nevertheless, recent creations, particularly from cartoonists, bear witness to a willingness to stretch language again in order to enhance language iconicity.

  10. Travel Diary-Based Emissions Analysis of Telecommuting for the Puget Sound Demonstration Project

    OpenAIRE

    Henderson, Dennis K; Koenig, Brett E; Mokhtarian, Patricia L

    1994-01-01

    Transportation control measures are often implemented for their environmental benefits, but there is a need to quantify what benefits actually occur. Telecommuting has the potential to reduce the number of daily trips and miles traveled with personal vehicles and consequently, the overall emissions resulting from vehicle activity. This research, sponsored by the Washington State Energy Office (WSEO), studies the emissions impacts of telecommuting for the participants of the Puget Sound Teleco...

  11. Sound Zones

    DEFF Research Database (Denmark)

    Møller, Martin Bo; Olsen, Martin

    2017-01-01

    Sound zones, i.e. spatially confined regions of individual audio content, can be created by appropriate filtering of the desired audio signals reproduced by an array of loudspeakers. The challenge of designing filters for sound zones is twofold: First, the filtered responses should generate...... an acoustic separation between the control regions. Secondly, the pre- and post-ringing as well as spectral deterioration introduced by the filters should be minimized. The tradeoff between acoustic separation and filter ringing is the focus of this paper. A weighted L2-norm penalty is introduced in the sound...

  12. Sound intensity

    DEFF Research Database (Denmark)

    Crocker, Malcolm J.; Jacobsen, Finn

    1998-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  13. Sound Intensity

    DEFF Research Database (Denmark)

    Crocker, M.J.; Jacobsen, Finn

    1997-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  14. The sound manifesto

    Science.gov (United States)

    O'Donnell, Michael J.; Bisnovatyi, Ilia

    2000-11-01

    Computing practice today depends on visual output to drive almost all user interaction. Other senses, such as audition, may be totally neglected, or used tangentially, or used in highly restricted specialized ways. We have excellent audio rendering through D-A conversion, but we lack rich general facilities for modeling and manipulating sound comparable in quality and flexibility to graphics. We need coordinated research in several disciplines to improve the use of sound as an interactive information channel. Incremental and separate improvements in synthesis, analysis, speech processing, audiology, acoustics, music, etc. will not alone produce the radical progress that we seek in sonic practice. We also need to create a new central topic of study in digital audio research. The new topic will assimilate the contributions of different disciplines on a common foundation. The key central concept that we lack is sound as a general-purpose information channel. We must investigate the structure of this information channel, which is driven by the cooperative development of auditory perception and physical sound production. Particular audible encodings, such as speech and music, illuminate sonic information by example, but they are no more sufficient for a characterization than typography is sufficient for characterization of visual information. To develop this new conceptual topic of sonic information structure, we need to integrate insights from a number of different disciplines that deal with sound. In particular, we need to coordinate central and foundational studies of the representational models of sound with specific applications that illuminate the good and bad qualities of these models. Each natural or artificial process that generates informative sound, and each perceptual mechanism that derives information from sound, will teach us something about the right structure to attribute to the sound itself. The new Sound topic will combine the work of computer

  15. Histological findings and lung dust analysis as the basis for occupational disease compensation in asbestos-related lung cancer in Germany.

    Science.gov (United States)

    Feder, Inke Sabine; Theile, Anja; Tannapfel, Andrea

    2018-01-15

    This study has researched the significance of histologically raised findings and lung dust analyses in the context of claiming the recognition of and thus compensation for an asbestos-associated occupational disease. For this approach, all findings from the German Mesothelioma Register in 2015 that included lung dust analyses were evaluated and were compared with information on asbestos fiber exposure at work based on fiber years, and with the results of radiological findings. For 68 insured persons, recognition of an asbestos-induced lung disease according to Section 4104 of the German Ordinance on Occupational Diseases (Berufskrankheitenverordnung - BKV) could be recommended solely on the basis of the histological examinations of lung tissues and complementary lung dust analyses. Neither did the calculation of the cumulative asbestos dust exposure at work yield 25 fiber years, nor could bridge findings (e.g., plaques) be identified. In addition, the autopsies of 12 patients revealed plaques that had not been diagnosed during radiological examinations. These results show that - irrespective of the prescribed working techniques and radiological diagnosis - pathological/anatomical and histological diagnostics are often the only way for the insureds to demonstrate the causal connection between asbestos and their disease. Even after long intervals of up to 40 years post last exposure, the asbestos fibers would still be easily detectable in the lung tissues evaluated. Whenever suitable tissue is available, it should be examined for mild asbestosis with the aid of a lung dust analysis. Otherwise there is a risk that an occupational disease is wrongfully rejected. In the context of health insurance, the lung dust analysis and the resulting proof of the presence of asbestosis often constitute one option of providing evidence of an occupational disease. Int J Occup Med Environ Health 2018;31(3):293-305. This work is available in Open Access model and licensed under a CC BY

  16. Validation of PC-based Sound Card with Biopac for Digitalization of ECG Recording in Short-term HRV Analysis.

    Science.gov (United States)

    Maheshkumar, K; Dilara, K; Maruthy, K N; Sundareswaren, L

    2016-07-01

    Heart rate variability (HRV) analysis is a simple and noninvasive technique capable of assessing autonomic nervous system modulation on heart rate (HR) in healthy as well as disease conditions. The aim of the present study was to compare (validate) the HRV using a temporal series of electrocardiograms (ECG) obtained by simple analog amplifier with PC-based sound card (audacity) and Biopac MP36 module. Based on the inclusion criteria, 120 healthy participants, including 72 males and 48 females, participated in the present study. Following standard protocol, 5-min ECG was recorded after 10 min of supine rest by Portable simple analog amplifier PC-based sound card as well as by Biopac module with surface electrodes in Leads II position simultaneously. All the ECG data was visually screened and was found to be free of ectopic beats and noise. RR intervals from both ECG recordings were analyzed separately in Kubios software. Short-term HRV indexes in both time and frequency domain were used. The unpaired Student's t-test and Pearson correlation coefficient test were used for the analysis using the R statistical software. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV. Correlation analysis revealed perfect positive correlation (r = 0.99, P < 0.001) between the values in time and frequency domain obtained by the devices. On the basis of the results of the present study, we suggest that the calculation of HRV values in the time and frequency domains by RR series obtained from the PC-based sound card is probably as reliable as those obtained by the gold standard Biopac MP36.

  17. Cannabis Smoking and Risk of Lung Cancer - A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    khalid BOUTI

    2014-12-01

    Full Text Available Background: Cannabis is the illicit psychoactive substance the most consumed in the world. Little is known about the association between the use of cannabis and the risk of lung cancer.Objective:The objective of this meta-analysis is to determine whether use of cannabis is a risk factor for lung cancer.Methods: We conducted a systematic review and meta-analyses of all languages articles using relevant computerised databases. MEDLINE (online PubMed, Web of knowledge, Embase, EBSCO CINAHL, ScienceDirect, Scopus, Cochrane Library, and Directory of Open Access Journals were searched to September 2014 for cohorts and case-control studies that assessed the risk of lung cancer associated with cannabis smoking.  The literature search was performed with a combination of medical subject headings terms, "cannabis" and "lung neoplasms". Data extraction: Two investigators independently analysed and extracted results from eligible studies.Our study's registration number on PROSPERO is  CRD42014008872.Results: The search strategy identified 2476 citations. 13 studies were eligible for inclusion: 2 pooled analysis of 9 case-control studies, one case-control study and 3 cohorts.The cumulative analysis for all the studies under a fixed-effects model showed that cannabis smoking determined an increased risk of developing lung cancer in the future (relative risk 1.22, 95% confidence interval 0.999–1.5; p=0.051, with no evidence of heterogeneity across the studies (I2: 34%; p¼0.01.Conclusions: The use of cannabis with or without tobacco smoking is associated with an increased risk for lung cancer.

  18. Wood dust exposure and lung cancer risk: a meta-analysis.

    Science.gov (United States)

    Hancock, David G; Langley, Mary E; Chia, Kwan Leung; Woodman, Richard J; Shanahan, E Michael

    2015-12-01

    Occupational lung cancers represent a major health burden due to their increasing prevalence and poor long-term outcomes. While wood dust is a confirmed human carcinogen, its association with lung cancer remains unclear due to inconsistent findings in the literature. We aimed to clarify this association using meta-analysis. We performed a search of 10 databases to identify studies published until June 2014. We assessed the lung cancer risk associated with wood dust exposure as the primary outcome and with wood dust-related occupations as a secondary outcome. Random-effects models were used to pool summary risk estimates. 85 publications were included in the meta-analysis. A significantly increased risk for developing lung cancer was observed among studies that directly assessed wood dust exposure (RR 1.21, 95% CI 1.05 to 1.39, n=33) and that assessed wood dust-related occupations (RR 1.15, 95% CI 1.07 to 1.23, n=59). In contrast, a reduced risk for lung cancer was observed among wood dust (RR 0.63, 95% CI 0.39 to 0.99, n=5) and occupation (RR 0.96, 95% CI 0.95 to 0.98, n=1) studies originating in Nordic countries, where softwood dust is the primary exposure. These results were independent of the presence of adjustment for smoking and exposure classification methods. Only minor differences in risk between the histological subtypes were identified. This meta-analysis provides strong evidence for an association between wood dust and lung cancer, which is critically influenced by the geographic region of the study. The reasons for this region-specific effect estimates remain to be clarified, but may suggest a differential effect for hardwood and softwood dusts. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heerink, W.J.; Vliegenthart, R. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Bock, G.H. de [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Epidemiology, University of Groningen, Groningen (Netherlands); Jonge, G.J. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Groen, H.J.M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Pulmonary Medicine, University of Groningen, Groningen (Netherlands); Oudkerk, M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands)

    2017-01-15

    To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. (orig.)

  20. Lung parenchymal analysis on dynamic MRI in thoracic insufficiency syndrome to assess changes following surgical intervention

    Science.gov (United States)

    Jagadale, Basavaraj N.; Udupa, Jayaram K.; Tong, Yubing; Wu, Caiyun; McDonough, Joseph; Torigian, Drew A.; Campbell, Robert M.

    2018-02-01

    General surgeons, orthopedists, and pulmonologists individually treat patients with thoracic insufficiency syndrome (TIS). The benefits of growth-sparing procedures such as Vertical Expandable Prosthetic Titanium Rib (VEPTR)insertionfor treating patients with TIS have been demonstrated. However, at present there is no objective assessment metricto examine different thoracic structural components individually as to their roles in the syndrome, in contributing to dynamics and function, and in influencing treatment outcome. Using thoracic dynamic MRI (dMRI), we have been developing a methodology to overcome this problem. In this paper, we extend this methodology from our previous structural analysis approaches to examining lung tissue properties. We process the T2-weighted dMRI images through a series of steps involving 4D image construction of the acquired dMRI images, intensity non-uniformity correction and standardization of the 4D image, lung segmentation, and estimation of the parameters describing lung tissue intensity distributions in the 4D image. Based on pre- and post-operative dMRI data sets from 25 TIS patients (predominantly neuromuscular and congenital conditions), we demonstrate how lung tissue can be characterized by the estimated distribution parameters. Our results show that standardized T2-weighted image intensity values decrease from the pre- to post-operative condition, likely reflecting improved lung aeration post-operatively. In both pre- and post-operative conditions, the intensity values decrease also from end-expiration to end-inspiration, supporting the basic premise of our results.

  1. Automated Image Analysis of Lung Branching Morphogenesis from Microscopic Images of Fetal Rat Explants

    Science.gov (United States)

    Rodrigues, Pedro L.; Rodrigues, Nuno F.; Duque, Duarte; Granja, Sara; Correia-Pinto, Jorge; Vilaça, João L.

    2014-01-01

    Background. Regulating mechanisms of branching morphogenesis of fetal lung rat explants have been an essential tool for molecular research. This work presents a new methodology to accurately quantify the epithelial, outer contour, and peripheral airway buds of lung explants during cellular development from microscopic images. Methods. The outer contour was defined using an adaptive and multiscale threshold algorithm whose level was automatically calculated based on an entropy maximization criterion. The inner lung epithelium was defined by a clustering procedure that groups small image regions according to the minimum description length principle and local statistical properties. Finally, the number of peripheral buds was counted as the skeleton branched ends from a skeletonized image of the lung inner epithelia. Results. The time for lung branching morphometric analysis was reduced in 98% in contrast to the manual method. Best results were obtained in the first two days of cellular development, with lesser standard deviations. Nonsignificant differences were found between the automatic and manual results in all culture days. Conclusions. The proposed method introduces a series of advantages related to its intuitive use and accuracy, making the technique suitable to images with different lighting characteristics and allowing a reliable comparison between different researchers. PMID:25250057

  2. Automated Image Analysis of Lung Branching Morphogenesis from Microscopic Images of Fetal Rat Explants

    Directory of Open Access Journals (Sweden)

    Pedro L. Rodrigues

    2014-01-01

    Full Text Available Background. Regulating mechanisms of branching morphogenesis of fetal lung rat explants have been an essential tool for molecular research. This work presents a new methodology to accurately quantify the epithelial, outer contour, and peripheral airway buds of lung explants during cellular development from microscopic images. Methods. The outer contour was defined using an adaptive and multiscale threshold algorithm whose level was automatically calculated based on an entropy maximization criterion. The inner lung epithelium was defined by a clustering procedure that groups small image regions according to the minimum description length principle and local statistical properties. Finally, the number of peripheral buds was counted as the skeleton branched ends from a skeletonized image of the lung inner epithelia. Results. The time for lung branching morphometric analysis was reduced in 98% in contrast to the manual method. Best results were obtained in the first two days of cellular development, with lesser standard deviations. Nonsignificant differences were found between the automatic and manual results in all culture days. Conclusions. The proposed method introduces a series of advantages related to its intuitive use and accuracy, making the technique suitable to images with different lighting characteristics and allowing a reliable comparison between different researchers.

  3. Correlation Analysis of PM10 and the Incidence of Lung Cancer in Nanchang, China

    Science.gov (United States)

    Zhou, Yi; Li, Lianshui; Hu, Lei

    2017-01-01

    Air pollution and lung cancer are closely related. In 2013, the World Health Organization listed outdoor air pollution as carcinogenic and regarded it as the most widespread carcinogen that humans are currently exposed to. Here, grey correlation and data envelopment analysis methods are used to determine the pollution factors causing lung cancer among residents in Nanchang, China, and identify population segments which are more susceptible to air pollution. This study shows that particulate matter with particle sizes below 10 micron (PM10) is most closely related to the incidence of lung cancer among air pollution factors including annual mean concentrations of SO2, NO2, PM10, annual haze days, and annual mean Air Pollution Index/Air Quality Index (API/AQI). Air pollution has a greater impact on urban inhabitants as compared to rural inhabitants. When gender differences are considered, women are more likely to develop lung cancer due to air pollution. Smokers are more likely to suffer from lung cancer. These results provide a reference for the government to formulate policies to reduce air pollutant emissions and strengthen anti-smoking measures. PMID:29048397

  4. Correlation Analysis of PM10 and the Incidence of Lung Cancer in Nanchang, China

    Directory of Open Access Journals (Sweden)

    Yi Zhou

    2017-10-01

    Full Text Available Air pollution and lung cancer are closely related. In 2013, the World Health Organization listed outdoor air pollution as carcinogenic and regarded it as the most widespread carcinogen that humans are currently exposed to. Here, grey correlation and data envelopment analysis methods are used to determine the pollution factors causing lung cancer among residents in Nanchang, China, and identify population segments which are more susceptible to air pollution. This study shows that particulate matter with particle sizes below 10 micron (PM10 is most closely related to the incidence of lung cancer among air pollution factors including annual mean concentrations of SO2, NO2, PM10, annual haze days, and annual mean Air Pollution Index/Air Quality Index (API/AQI. Air pollution has a greater impact on urban inhabitants as compared to rural inhabitants. When gender differences are considered, women are more likely to develop lung cancer due to air pollution. Smokers are more likely to suffer from lung cancer. These results provide a reference for the government to formulate policies to reduce air pollutant emissions and strengthen anti-smoking measures.

  5. Correlation Analysis of PM10 and the Incidence of Lung Cancer in Nanchang, China.

    Science.gov (United States)

    Zhou, Yi; Li, Lianshui; Hu, Lei

    2017-10-19

    Air pollution and lung cancer are closely related. In 2013, the World Health Organization listed outdoor air pollution as carcinogenic and regarded it as the most widespread carcinogen that humans are currently exposed to. Here, grey correlation and data envelopment analysis methods are used to determine the pollution factors causing lung cancer among residents in Nanchang, China, and identify population segments which are more susceptible to air pollution. This study shows that particulate matter with particle sizes below 10 micron (PM 10 ) is most closely related to the incidence of lung cancer among air pollution factors including annual mean concentrations of SO₂, NO₂, PM 10 , annual haze days, and annual mean Air Pollution Index/Air Quality Index (API/AQI). Air pollution has a greater impact on urban inhabitants as compared to rural inhabitants. When gender differences are considered, women are more likely to develop lung cancer due to air pollution. Smokers are more likely to suffer from lung cancer. These results provide a reference for the government to formulate policies to reduce air pollutant emissions and strengthen anti-smoking measures.

  6. Sound Art Situations

    DEFF Research Database (Denmark)

    Krogh Groth, Sanne; Samson, Kristine

    2017-01-01

    and combine theories from several fields. Aspects of sound art studies, performance studies and contemporary art studies are presented in order to theoretically explore the very diverse dimensions of the two sound art pieces: Visual, auditory, performative, social, spatial and durational dimensions become......This article is an analysis of two sound art performances that took place June 2015 in outdoor public spaces in the social housing area Urbanplanen in Copenhagen, Denmark. The two performances were On the production of a poor acoustics by Brandon LaBelle and Green Interactive Biofeedback...... Environments (GIBE) by Jeremy Woodruff. In order to investigate the complex situation that arises when sound art is staged in such contexts, the authors of this article suggest exploring the events through approaching them as ‘situations’ (Doherty 2009). With this approach it becomes possible to engage...

  7. Does social diversity impede sound economic management? An empirical analysis, 1980-2012.

    Science.gov (United States)

    de Soysa, Indra; Vadlamannati, Krishna Chaitanya

    2017-02-01

    Several celebrated scholars argue that diverse preferences and coordination failure due to ethnic and cultural diversity hamper the social cohesion necessary for good economic management, leading to development failure. Using several measures of diversity, we find that higher levels of ethno-linguistic and cultural fractionalization are conditioned positively on higher economic growth by an index of economic freedom, which is often heralded as a good measure of sound economic management. High diversity in turn is associated with higher levels of economic freedom. We do not find any evidence to suggest that high diversity hampers change towards greater economic freedom and institutions supporting liberal policies. The effect of diversity, moreover, is conditioned positively by higher democracy. Our results raise serious doubt about the centrality of social diversity for explaining economic failure, nor is there evidence to suggest that autocratic measures are required under conditions of social diversity to implement growth-promoting policies. This is good news because history and culture seem to matter less than rational agency for ensuring sound economic management. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Distinctive serum protein profiles involving abundant proteins in lung cancer patients based upon antibody microarray analysis

    International Nuclear Information System (INIS)

    Gao, Wei-Min; Haab, Brian B; Hanash, Samir M; Kuick, Rork; Orchekowski, Randal P; Misek, David E; Qiu, Ji; Greenberg, Alissa K; Rom, William N; Brenner, Dean E; Omenn, Gilbert S

    2005-01-01

    Cancer serum protein profiling by mass spectrometry has uncovered mass profiles that are potentially diagnostic for several common types of cancer. However, direct mass spectrometric profiling has a limited dynamic range and difficulties in providing the identification of the distinctive proteins. We hypothesized that distinctive profiles may result from the differential expression of relatively abundant serum proteins associated with the host response. Eighty-four antibodies, targeting a wide range of serum proteins, were spotted onto nitrocellulose-coated microscope slides. The abundances of the corresponding proteins were measured in 80 serum samples, from 24 newly diagnosed subjects with lung cancer, 24 healthy controls, and 32 subjects with chronic obstructive pulmonary disease (COPD). Two-color rolling-circle amplification was used to measure protein abundance. Seven of the 84 antibodies gave a significant difference (p < 0.01) for the lung cancer patients as compared to healthy controls, as well as compared to COPD patients. Proteins that exhibited higher abundances in the lung cancer samples relative to the control samples included C-reactive protein (CRP; a 13.3 fold increase), serum amyloid A (SAA; a 2.0 fold increase), mucin 1 and α-1-antitrypsin (1.4 fold increases). The increased expression levels of CRP and SAA were validated by Western blot analysis. Leave-one-out cross-validation was used to construct Diagonal Linear Discriminant Analysis (DLDA) classifiers. At a cutoff where all 56 of the non-tumor samples were correctly classified, 15/24 lung tumor patient sera were correctly classified. Our results suggest that a distinctive serum protein profile involving abundant proteins may be observed in lung cancer patients relative to healthy subjects or patients with chronic disease and may have utility as part of strategies for detecting lung cancer

  9. Comparative Proteomic Analysis of Human Lung Adenocarcinoma Cisplatin-resistant Cell Strain A549/CDDP

    Directory of Open Access Journals (Sweden)

    Sien SHI

    2009-11-01

    Full Text Available Background and objective Chemotherapy plays an important role in the comprehensive therapy of lung cancer. However, the drug-resistance often causes the failure of the chemotherapy. The aim of this study is to identify differently expressed protein before and after cisplatin resistance of human lung adenocarcinoma cell A549 by proteomic analysis. Methods Cisplatin-resistant cell strain A549/CDDP was established by combining gradually increasing concentration of cisplatin with large dosage impact. Comparative proteomic analysis of A549 and A549/CDDP were carried out by means of two-dimensional gel electrophoresis. The differentially expressed proteins were detected and identified by MALDI-TOF mass spectrometry. Results Eighty-two differentially expressed proteins were screened by analysis the electrophoretic maps of A549 and A549/CDDP. Six differential proteins were analyzed by peptide mass fingerprinting. Glucose regulating protein 75, ribosomal protein S4, mitochondrial ATP synthase F1 complex beta subunit and immunoglobulin heavy chain variable region were identified. All four differentially expressed proteins were over-expressed in A549/CDDP, whereas low-expressed or no-expressed in A549. Conclusion These differentially expressed proteins give some clues to elucidate the mechanism of lung cancer cell resistant of cisplatin, providing the basis of searching for potential target of chemotherapy of lung cancer.

  10. A retrospective analysis of delays in the diagnosis of lung cancer and associated costs

    Directory of Open Access Journals (Sweden)

    Gildea TR

    2017-05-01

    Full Text Available Thomas R Gildea,1 Stacey DaCosta Byfield,2 D Kyle Hogarth,3 David S Wilson,4 Curtis C Quinn5 1Department of Pulmonary, Allergy, and Critical Care Medicine and Transplant Center, Cleveland Clinic, Cleveland, OH, 2Health Economics and Outcomes Research, Optum, Eden Prairie, MN, 3Department of Medicine, Section of Pulmonary and Critical Care, University of Chicago Medical Center, Chicago, IL, 4The Lung Institute, Columbus Regional Hospital, Columbus, IN, 5Cardiothoracic Surgery/Thoracic Surgery, Cardiothoracic Surgery of Charleston, Roper St. Francis Physician Partners Group, Charleston, SC, USA Purpose: Diagnosis of lung cancer at advanced stages can result in missed treatment opportunities, worse outcomes, and higher health care costs. This study evaluated the wait time to diagnose non-small-cell lung cancer (NSCLC and the cost of diagnosis and treatment based on the stage at diagnosis. Patients and methods: Adult patients diagnosed with NSCLC between January 2007 and September 2011 were identified from a proprietary oncology registry and linked to health insurance claims from a large US health insurance company. Continuous enrollment in the health plan was required for at least 12 months prediagnosis (baseline and at least 3 months postdiagnosis (follow-up. Use of diagnostic tests and time to diagnosis were examined. The rates of health care utilization and per-patient per-month (PPPM health care costs were calculated. Results: A total of 1,210 patients with NSCLC were included in the analysis. Most patients (93.6% had evidence of diagnostic tests beginning 5 to 6 months prior to diagnosis, and most were diagnosed at an advanced stage (23% Stage IIIb and 46% Stage IV. The PPPM total health care costs in USD pre- and postdiagnosis were $2,407±$3,364 (mean±standard deviation and $16,577±$33,550, respectively. PPPM total health care costs and utilization after lung cancer diagnosis were significantly higher among patients diagnosed at Stage

  11. meta-analysis of the Relationship between Passive Smoking Population in China and Lung Cancer

    Directory of Open Access Journals (Sweden)

    Hui ZHAO

    2010-06-01

    Full Text Available Background and objective Studies of passive smoking exposure in China however are of particular interest, because of the high lung cancer rate in people who are mostly non-smokers. The aim of this study is to explore the relationship between passive smoking and lung cancer among non-smoking Chinese. Methods By searching Medline, PubMed, CENTRAL (the Cochrane central register of controlled trials, CBM, CNKI and VIP, et al, we collected both domestic and overseas published documents between 1987 and 2007 on passive smoking and lung cancer among non-smoking Chinese. Random or fixed effect models were applied to conduct meta-analysis on the case control study results, and the combined odds ratio (OR and the 95% confidence interval (CI were calculated as well. Results Sixteen documents were included into the combined analysis, which indicated that there was statistical significance between passive smoking and lung cancer (OR=1.13, 95%CI: 1.05-1.21, P=0.001. It was significant of lung cancer among non-smoking subjects associated with amount of tobacco passively smoked more than 20 cigarettes daily, with life period in adulthood passive smoking exposure, with gender female, and with exposure to workplace. The P value, OR and 95%CI were P=0.000 3, OR=1.78, 95%CI: 1.30-2.43; P=0.000 1, OR=1.50, 95%CI: 1.23-1.83; P=0.000 7, OR=1.50, 95%CI: 1.19-1.90; P<0.000 1, OR=1.41, 95%CI: 1.19-1.66; respectively. And there was no significant difference between passive smoking and lung cancer with amount of tobacco passively smoked within 20 cigarettes daily, with life period in childhood passive smoking exposure, with gender male and with exposure to spouse and parents. Conclusion Passive smoking is an important risk factor of lung cancer among non-smoking Chinese, and for non-smoking women who expose to environment tobacco smoke in a long period of time have a close relationship with lung cancer risk.

  12. Intraoperative mechanical ventilation strategies in patients undergoing one-lung ventilation: a meta-analysis.

    Science.gov (United States)

    Liu, Zhen; Liu, Xiaowen; Huang, Yuguang; Zhao, Jing

    2016-01-01

    Postoperative pulmonary complications (PPCs), which are not uncommon in one-lung ventilation, are among the main causes of postoperative death after lung surgery. Intra-operative ventilation strategies can influence the incidence of PPCs. High tidal volume (V T) and increased airway pressure may lead to lung injury, while pressure-controlled ventilation and lung-protective strategies with low V T may have protective effects against lung injury. In this meta-analysis, we aim to investigate the effects of different ventilation strategies, including pressure-controlled ventilation (PCV), volume-controlled ventilation (VCV), protective ventilation (PV) and conventional ventilation (CV), on PPCs in patients undergoing one-lung ventilation. We hypothesize that both PV with low V T and PCV have protective effects against PPCs in one-lung ventilation. A systematic search (PubMed, EMBASE, the Cochrane Library, and Ovid MEDLINE; in May 2015) was performed for randomized trials comparing PCV with VCV or comparing PV with CV in one-lung ventilation. Methodological quality was evaluated using the Cochrane tool for risk. The primary outcome was the incidence of PPCs. The secondary outcomes included the length of hospital stay, intraoperative plateau airway pressure (Pplateau), oxygen index (PaO2/FiO2) and mean arterial pressure (MAP). In this meta-analysis, 11 studies (436 patients) comparing PCV with VCV and 11 studies (657 patients) comparing PV with CV were included. Compared to CV, PV decreased the incidence of PPCs (OR 0.29; 95 % CI 0.15-0.57; P < 0.01) and intraoperative Pplateau (MD -3.75; 95 % CI -5.74 to -1.76; P < 0.01) but had no significant influence on the length of hospital stay or MAP. Compared to VCV, PCV decreased intraoperative Pplateau (MD -1.46; 95 % CI -2.54 to -0.34; P = 0.01) but had no significant influence on PPCs, PaO2/FiO2 or MAP. PV with low V T was associated with the reduced incidence of PPCs compared to CV. However, PCV and VCV had similar

  13. Application of neutron activation analysis to trace element determinations in lung samples

    International Nuclear Information System (INIS)

    Rocero, Sizue Ota

    1992-01-01

    The purpose of this work was to apply the instrumental neutron activation analysis method to determine trace elements in lung samples from smokers and non smokers. Samples of lung tissues and lymph nodes from pulmonary hilum analyzed were collected from autopsies by researchers from the Medicine College of the University of Sao Paulo, SP, Brazil. Adequate conditions for preparation and analysis of samples were previously established. The preparation of samples consisted of homogenization, lyophilization and sterilization in 60 Co source. The samples and standards were irradiated in the IEA-R1 reactor under thermal neutron flux of 3.7 x 10 11 n.cm -2 .s -1 for 30 min to determine Cl, K, Mn and Na and for 16 h under flux of 10 19 n.cm -2 .s -1 for the determination of Au, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, La, Rb, Sb, Sc, Se, Th and Zn. The counting were carried out with a hiperpure (ge) detector connected to a 4096 channels analyzer and a microcomputer. the results obtained for lung sample analyses indicated a good reproducibility of the method for most of the elements determined with relative standard deviations lower than 10.5%. The accuracy of the method was evaluated by analyzing reference materials such as IAEA Animal Muscle H-4, NIST Bovine Liver 1577a, IUPAC Bowen's Kale and NIES Vehicle Exhaust Particulates. The results obtained from these analyzes agreed with the values of the literature for several elements with relative errors less than 20%. Less precise and accurate results were obtained for elements with concentrations at the Mup/Kg levels. Elemental concentrations obtained in the lung tissue analyses were within the range of reference values for normal subjects presented in the literature, except for the Cl concentrations for non smokers, Hf in both groups and Sb for the smokers. By comparing results obtained for lung samples from smokers and non smokers, the concentrations of Ce, Cr and Sb were higher in lungs from smokers and the others elements were

  14. Sound Settlements

    DEFF Research Database (Denmark)

    Mortensen, Peder Duelund; Hornyanszky, Elisabeth Dalholm; Larsen, Jacob Norvig

    2013-01-01

    Præsentation af projektresultater fra Interreg forskningen Sound Settlements om udvikling af bæredygtighed i det almene boligbyggerier i København, Malmø, Helsingborg og Lund samt europæiske eksempler på best practice......Præsentation af projektresultater fra Interreg forskningen Sound Settlements om udvikling af bæredygtighed i det almene boligbyggerier i København, Malmø, Helsingborg og Lund samt europæiske eksempler på best practice...

  15. Nuclear sound

    International Nuclear Information System (INIS)

    Wambach, J.

    1991-01-01

    Nuclei, like more familiar mechanical systems, undergo simple vibrational motion. Among these vibrations, sound modes are of particular interest since they reveal important information on the effective interactions among the constituents and, through extrapolation, on the bulk behaviour of nuclear and neutron matter. Sound wave propagation in nuclei shows strong quantum effects familiar from other quantum systems. Microscopic theory suggests that the restoring forces are caused by the complex structure of the many-Fermion wavefunction and, in some cases, have no classical analogue. The damping of the vibrational amplitude is strongly influenced by phase coherence among the particles participating in the motion. (author)

  16. Analysis of the Exxon Valdez oil spill impacts on Prince William Sound pink salmon

    International Nuclear Information System (INIS)

    Brannon, E.L.; Moulton, L.L.; Maki, A.W.

    1996-01-01

    The impact of the Exxon Valdez oil spill on pink salmon in Prince William Sound (PWS), was studied. Since the incident, numerous and extensive field and laboratory studies have been completed by various scientists. This paper synthesized information on the post-spill salmon harvests, the concentration of petroleum that entered the water column, the number of streams oiled, and stream sediment chemistry, to determine the potential for oil spill effects. Results from this study showed that oiling to the extent experienced during incubation and rearing during both the spring and fall of 1989 through the spring of 1991, resulted in no measurable effects on the PWS pink salmon. The estimated losses predicted earlier, likely exceeded actual losses. 16 refs., 4 tabs., 4 figs

  17. Analysis of diagnositc accuracy with CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Haiyan; Zhuang Yiping; Zhang Jin; Feng Yong; Zhang Xiao; Xu Lin

    2007-01-01

    Objective: To evaluate the factors which may affect the diagnostic accmracy of CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions. Methods: CT-guided percutaneous transthoracic lung biopsy was performed in 264 patients, all of which were proved by surgical pathology or clinical follow-up. A logistic regression analysis was used to investigate the relationship between the location and the size of the lesions and insertion depth of biopsy needles and the diagnostic accuracy of CT-guided percutaneous transthomcic lung biopsy. The complication rate including pneumatothorax and bleeding rate were record. Results: The diagnostic accuracy was 87.5%. Both the pneumothorax and the bleeding of lesion were 1.9%. The size of lesion was suggested by Logistic regression analysis had a significant influence on the diagnostic accuracy (Wald=12.891, P=0.00034, OR=0.96). Conclusion: CT-guided pereumneous transthoracic lung biopsy has a high diagnostic accuracy for pulmonary lesions. The size of the lesions had significant effect on the diagnostic accuracy. (authors)

  18. The cost of respirable coal mine dust: an analysis based on new black lung claims

    Energy Technology Data Exchange (ETDEWEB)

    Page, S.J.; Organiscak, J.A.; Lichtman, K. [US Bureau of Mines, Pittsburgh, PA (United States). Dept. of the Interior

    1997-12-01

    The article provides summation of the monetary costs of new compensation claims associated with levels of unmitigated respirable coal mine dust and the resultant lung disease known as black lung and compares these compensation costs to the cost of dust control technology research by the US Bureau of Mines. It presents an analysis of these expenditures and projects these costs over the period from 1991 to 2010, based on projected future new claims which are assumed to be approved for federal and state benefit payment. Since current and future dust control research efforts cannot change past claim histories, a valid comparison of future research spending with other incurred costs must examine only the cost of future new claims. The bias of old claim costs was eliminated in this analysis by examining only claims since 1980. The results estimate that for an expected 339 new approved claims annually from 1991 to 2010, the Federal Trust Fund costs will be 985 million dollars. During this same period, state black lung compensation is estimated to be 18.2 billion dollars. The Bureau of Mines dust control research expenditures are estimated as 0.44% of the projected future black lung-related costs. 9 refs., 4 figs., 3 tabs.

  19. Quantitative proteomic analysis of human lung tumor xenografts treated with the ectopic ATP synthase inhibitor citreoviridin.

    Directory of Open Access Journals (Sweden)

    Yi-Hsuan Wu

    Full Text Available ATP synthase is present on the plasma membrane of several types of cancer cells. Citreoviridin, an ATP synthase inhibitor, selectively suppresses the proliferation and growth of lung cancer without affecting normal cells. However, the global effects of targeting ectopic ATP synthase in vivo have not been well defined. In this study, we performed quantitative proteomic analysis using isobaric tags for relative and absolute quantitation (iTRAQ and provided a comprehensive insight into the complicated regulation by citreoviridin in a lung cancer xenograft model. With high reproducibility of the quantitation, we obtained quantitative proteomic profiling with 2,659 proteins identified. Bioinformatics analysis of the 141 differentially expressed proteins selected by their relative abundance revealed that citreoviridin induces alterations in the expression of glucose metabolism-related enzymes in lung cancer. The up-regulation of enzymes involved in gluconeogenesis and storage of glucose indicated that citreoviridin may reduce the glycolytic intermediates for macromolecule synthesis and inhibit cell proliferation. Using comprehensive proteomics, the results identify metabolic aspects that help explain the antitumorigenic effect of citreoviridin in lung cancer, which may lead to a better understanding of the links between metabolism and tumorigenesis in cancer therapy.

  20. Pooled Bayesian analysis of 28 studies on radon induced lung cancers

    International Nuclear Information System (INIS)

    Fornalski, K.W.; Dobrzyński, L.

    2010-01-01

    The influence of ionizing radiation of radon-222 and its daughters on the lung cancer incidence and mortality published in 28 papers was reanalyzed, for two ranges of low annual radiation dose of below 70 mSv per year (391 Bq m -3 ) and 150 mSv per year (838 Bq m -3 ). The seven popular models of dose-effect relationship were tested. The assumption-free Bayesian statistical methods were used for all curve fittings. Also the Model Selection algorithm was used to verify the relative probability of all seven models. The results of the analysis demonstrate that in this ranges of doses (below 70 and 150 mSv/ year) the published data do not show the presence of a risk of lung cancer induction. The most probable dose-effect relationship is constant one (risk ratio, RR=1). The statistical analysis shows that there is no basis for increase the risk of lung cancer in low dose area. The final conclusion results from the fact that the model assuming no dependence of the lung cancer induction on the radiation doses is at least 100 times more likely than six other models tested, including the Linear No-Threshold (LNT) model

  1. Protective Lung Ventilation and Morbidity After Pulmonary Resection: A Propensity Score-Matched Analysis.

    Science.gov (United States)

    Amar, David; Zhang, Hao; Pedoto, Alessia; Desiderio, Dawn P; Shi, Weiji; Tan, Kay See

    2017-07-01

    Protective lung ventilation (PLV) during one-lung ventilation (OLV) for thoracic surgery is frequently recommended to reduce pulmonary complications. However, limited outcome data exist on whether PLV use during OLV is associated with less clinically relevant pulmonary morbidity after lung resection. Intraoperative data were prospectively collected in 1080 patients undergoing pulmonary resection with OLV, intentional crystalloid restriction, and mechanical ventilation to maintain inspiratory peak airway pressure volume. The primary outcome was the occurrence of pneumonia and/or acute respiratory distress syndrome (ARDS). Propensity score matching was used to generate PLV and non-PLV groups with comparable characteristics. Associations between outcomes and PLV status were analyzed by exact logistic regression, with matching as cluster in the anatomic and nonanatomic lung resection cohorts. In the propensity score-matched analysis, the incidence of pneumonia and/or ARDS among patients who had an anatomic lung resection was 9/172 (5.2%) in the non-PLV compared to the PLV group 7/172 (4.1%; odds ratio, 1.29; 95% confidence interval, 0.48-3.45, P= .62). The incidence of pneumonia and/or ARDS in patients who underwent nonanatomic resection was 3/118 (2.5%) in the non-PLV compared to the PLV group, 1/118 (0.9%; odds ratio, 3.00; 95% confidence interval, 0.31-28.84, P= .34). In this prospective observational study, we found no differences in the incidence of pneumonia and/or ARDS between patients undergoing lung resection with tidal volumes volume strategy during OLV on clinically important outcomes.

  2. Towards lung EIT image segmentation: automatic classification of lung tissue state from analysis of EIT monitored recruitment manoeuvres

    International Nuclear Information System (INIS)

    Grychtol, Bartłomiej; Wolf, Gerhard K; Arnold, John H; Adler, Andy

    2010-01-01

    There is emerging evidence that the ventilation strategy used in acute lung injury (ALI) makes a significant difference in outcome and that an inappropriate ventilation strategy may produce ventilator-associated lung injury. Most harmful during mechanical ventilation are lung overdistension and lung collapse or atelectasis. Electrical impedance tomography (EIT) as a non-invasive imaging technology may be helpful to identify lung areas at risk. Currently, no automated method is routinely available to identify lung areas that are overdistended, collapsed or ventilated appropriately. We propose a fuzzy logic-based algorithm to analyse EIT images obtained during stepwise changes of mean airway pressures during mechanical ventilation. The algorithm is tested on data from two published studies of stepwise inflation–deflation manoeuvres in an animal model of ALI using conventional and high-frequency oscillatory ventilation. The timing of lung opening and collapsing on segmented images obtained using the algorithm during an inflation–deflation manoeuvre is in agreement with well-known effects of surfactant administration and changes in shunt fraction. While the performance of the algorithm has not been verified against a gold standard, we feel that it presents an important first step in tackling this challenging and important problem

  3. Towards lung EIT image segmentation: automatic classification of lung tissue state from analysis of EIT monitored recruitment manoeuvres.

    Science.gov (United States)

    Grychtol, Bartłomiej; Wolf, Gerhard K; Adler, Andy; Arnold, John H

    2010-08-01

    There is emerging evidence that the ventilation strategy used in acute lung injury (ALI) makes a significant difference in outcome and that an inappropriate ventilation strategy may produce ventilator-associated lung injury. Most harmful during mechanical ventilation are lung overdistension and lung collapse or atelectasis. Electrical impedance tomography (EIT) as a non-invasive imaging technology may be helpful to identify lung areas at risk. Currently, no automated method is routinely available to identify lung areas that are overdistended, collapsed or ventilated appropriately. We propose a fuzzy logic-based algorithm to analyse EIT images obtained during stepwise changes of mean airway pressures during mechanical ventilation. The algorithm is tested on data from two published studies of stepwise inflation-deflation manoeuvres in an animal model of ALI using conventional and high-frequency oscillatory ventilation. The timing of lung opening and collapsing on segmented images obtained using the algorithm during an inflation-deflation manoeuvre is in agreement with well-known effects of surfactant administration and changes in shunt fraction. While the performance of the algorithm has not been verified against a gold standard, we feel that it presents an important first step in tackling this challenging and important problem.

  4. Heart Sound Localization and Reduction in Tracheal Sounds by Gabor Time-Frequency Masking

    OpenAIRE

    SAATCI, Esra; Akan, Aydın

    2018-01-01

    Background and aim: Respiratorysounds, i.e. tracheal and lung sounds, have been of great interest due to theirdiagnostic values as well as the potential of their use in the estimation ofthe respiratory dynamics (mainly airflow). Thus the aim of the study is topresent a new method to filter the heart sound interference from the trachealsounds. Materials and methods: Trachealsounds and airflow signals were collected by using an accelerometer from 10 healthysubjects. Tracheal sounds were then pr...

  5. Sound Settlements

    DEFF Research Database (Denmark)

    Mortensen, Peder Duelund; Hornyanszky, Elisabeth Dalholm; Larsen, Jacob Norvig

    2013-01-01

    Præsentation af projektresultater fra Interreg forskningen Sound Settlements om udvikling af bæredygtighed i det almene boligbyggerier i København, Malmø, Helsingborg og Lund samt europæiske eksempler på best practice...

  6. Second Sound

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 6. Second Sound - The Role of Elastic Waves. R Srinivasan. General Article Volume 4 Issue 6 June 1999 pp 15-19. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/004/06/0015-0019 ...

  7. An alternative respiratory sounds classification system utilizing artificial neural networks

    Directory of Open Access Journals (Sweden)

    Rami J Oweis

    2015-04-01

    Full Text Available Background: Computerized lung sound analysis involves recording lung sound via an electronic device, followed by computer analysis and classification based on specific signal characteristics as non-linearity and nonstationarity caused by air turbulence. An automatic analysis is necessary to avoid dependence on expert skills. Methods: This work revolves around exploiting autocorrelation in the feature extraction stage. All process stages were implemented in MATLAB. The classification process was performed comparatively using both artificial neural networks (ANNs and adaptive neuro-fuzzy inference systems (ANFIS toolboxes. The methods have been applied to 10 different respiratory sounds for classification. Results: The ANN was superior to the ANFIS system and returned superior performance parameters. Its accuracy, specificity, and sensitivity were 98.6%, 100%, and 97.8%, respectively. The obtained parameters showed superiority to many recent approaches. Conclusions: The promising proposed method is an efficient fast tool for the intended purpose as manifested in the performance parameters, specifically, accuracy, specificity, and sensitivity. Furthermore, it may be added that utilizing the autocorrelation function in the feature extraction in such applications results in enhanced performance and avoids undesired computation complexities compared to other techniques.

  8. Performance analysis of an IMU-augmented GNSS tracking system on board the MAIUS-1 sounding rocket

    Science.gov (United States)

    Braun, Benjamin; Grillenberger, Andreas; Markgraf, Markus

    2018-05-01

    Satellite navigation receivers are adequate tracking sensors for range safety of both orbital launch vehicles and suborbital sounding rockets. Due to high accuracy and its low system complexity, satellite navigation is seen as well-suited supplement or replacement of conventional tracking systems like radar. Having the well-known shortcomings of satellite navigation like deliberate or unintentional interferences in mind, it is proposed to augment the satellite navigation receiver by an inertial measurement unit (IMU) to enhance continuity and availability of localization. The augmented receiver is thus enabled to output at least an inertial position solution in case of signal outages. In a previous study, it was shown by means of simulation using the example of Ariane 5 that the performance of a low-grade microelectromechanical IMU is sufficient to bridge expected outages of some ten seconds, and still meeting the range safety requirements in effect. In this publication, these theoretical findings shall be substantiated by real flight data that were recorded on MAIUS-1, a sounding rocket launched from Esrange, Sweden, in early 2017. The analysis reveals that the chosen representative of a microelectromechanical IMU is suitable to bridge outages of up to thirty seconds.

  9. Analysis of changes in radiographic lung image and lung ventilation disorders in workers occupationally exposed to chrysotile in the past

    Directory of Open Access Journals (Sweden)

    Elżbieta Cwynar

    2017-04-01

    Full Text Available Background: The adverse health effects of occupational exposure to asbestos dust may occur several years after first exposure. The objective of the study was to assess the relationship between lesions in the respiratory system and the factors contributing to occupational exposure to asbestos described in the first medical examination as well as to analyze the factors responsible for the progression of these changes in further medical tests. Material and Methods: The study group comprised 591 former workers of asbestos processing plant “Gambit” in Lubawka. The results of medical examinations carried out in 2001–2012 were assessed. Statistical inference was performed based on bilateral significance tests at the 0.05 level of significance. Results: A higher risk of interstitial lung changes along with an increase in the cumulative concentration of asbestos was indicated; for the employees with the highest exposure, the adjusted odds ratio (OR was 1.63 (95% confidence interval (CI: 0.99–2.71, while for changes with the severity degree qualifying for asbestosis diagnosis, the risk was significantly increased, over fivefold higher, compared to subjects employed in the lowest exposure. The analysis of the relationship between the progression of interstitial changes and the exposure to asbestos dust showed a fourfold higher risk of the progression in workers employed in the highest exposure. Mean values of FEV1 (forced expiratory volume in 1 s, FVC (forced vital capacity, FEV1/FVC (forced expiratory volume in 1 s to forced vital capacity were significantly lower in the subjects working in a higher asbestos exposure. The effect of tobacco smoking on the occurrence of interstitial lung changes and their progression was also confirmed. Conclusions: The results of prophylactic medical examinations of the health status of workers formerly employed in the plants using chrysotile indicate the importance andthe need for a long-term clinical follow

  10. Severity of pulmonary emphysema and lung cancer: analysis using quantitative lobar emphysema scoring.

    Science.gov (United States)

    Bae, Kyungsoo; Jeon, Kyung Nyeo; Lee, Seung Jun; Kim, Ho Cheol; Ha, Ji Young; Park, Sung Eun; Baek, Hye Jin; Choi, Bo Hwa; Cho, Soo Buem; Moon, Jin Il

    2016-11-01

    The aim of this study was to determine the relationship between lobar severity of emphysema and lung cancer using automated lobe segmentation and emphysema quantification methods.This study included 78 patients (74 males and 4 females; mean age of 72 years) with the following conditions: pathologically proven lung cancer, available chest computed tomographic (CT) scans for lobe segmentation, and quantitative scoring of emphysema. The relationship between emphysema and lung cancer was analyzed using quantitative emphysema scoring of each pulmonary lobe.The most common location of cancer was the left upper lobe (LUL) (n = 28), followed by the right upper lobe (RUL) (n = 27), left lower lobe (LLL) (n = 13), right lower lobe (RLL) (n = 9), and right middle lobe (RML) (n = 1). Emphysema ratio was the highest in LUL, followed by that in RUL, LLL, RML, and RLL. Multivariate logistic regression analysis revealed that upper lobes (odds ratio: 1.77; 95% confidence interval: 1.01-3.11, P = 0.048) and lobes with emphysema ratio ranked the 1st or the 2nd (odds ratio: 2.48; 95% confidence interval: 1.48-4.15, P emphysema patients, lung cancer has a tendency to develop in lobes with more severe emphysema.

  11. Clinical Evaluation and Cost-Effectiveness Analysis of Serum Tumor Markers in Lung Cancer

    Directory of Open Access Journals (Sweden)

    Rong Wang

    2013-01-01

    Full Text Available The detection of serum tumor markers is valuable for the early diagnosis of lung cancer. Tumor markers are frequently used for the management of cancer patients. However, single markers are less efficient but marker combinations increase the cost, which is troublesome for clinics. To find an optimal serum marker combination panel that benefits the patients and the medical management system as well, four routine lung cancer serum markers (SCCA, NSE, CEA, and CYFRA21-1 were evaluated individually and in combination. Meanwhile, the costs and effects of these markers in clinical practice in China were assessed by cost-effectiveness analysis. As expected, combinations of these tumor markers improved their sensitivity for lung cancer and different combination panels had their own usefulness. NSE + CEA + CYFRA21-1 was the optimal combination panel with highest Youden’s index (0.64, higher sensitivity (75.76%, and specificity (88.57%, which can aid the clinical diagnosis of lung cancer. Nevertheless, the most cost-effective combination was SCCA + CEA, which can be used to screen the high-risk group.

  12. The potential for bias in Cohen's ecological analysis of lung cancer and residential radon

    International Nuclear Information System (INIS)

    Lubin, Jay H.

    2002-01-01

    Cohen's ecological analysis of US lung cancer mortality rates and mean county radon concentration shows decreasing mortality rates with increasing radon concentration (Cohen 1995 Health Phys. 68 157-74). The results prompted his rejection of the linear-no-threshold (LNT) model for radon and lung cancer. Although several authors have demonstrated that risk patterns in ecological analyses provide no inferential value for assessment of risk to individuals, Cohen advances two arguments in a recent response to Darby and Doll (2000 J. Radiol. Prot. 20 221-2) who suggest Cohen's results are and will always be burdened by the ecological fallacy. Cohen asserts that the ecological fallacy does not apply when testing the LNT model, for which average exposure determines average risk, and that the influence of confounding factors is obviated by the use of large numbers of stratification variables. These assertions are erroneous. Average dose determines average risk only for models which are linear in all covariates, in which case ecological analyses are valid. However, lung cancer risk and radon exposure, while linear in the relative risk, are not linearly related to the scale of absolute risk, and thus Cohen's rejection of the LNT model is based on a false premise of linearity. In addition, it is demonstrated that the deleterious association for radon and lung cancer observed in residential and miner studies is consistent with negative trends from ecological studies, of the type described by Cohen. (author)

  13. [Evaluation of nutritional Status in lung cancer using bio electrical impedance analysis and mini nutritional assessment].

    Science.gov (United States)

    Daghfous, Hafaoua; El Ayeb, Wejdène; Alouane, Leila; Tritar, Fatma

    2014-12-01

    Malnutrition and cachexia were a frequent problem in lung cancer and increases the risks of morbidity and mortality in these patients. Bioelectrical impedance analysis (BIA) is easy, non-invasive and reproducible method that can be performed. Evaluate nutritional status in patients with primary lung cancer by Mini Nutritional Assessment (MNA), BIA and anthropometric values (weight, arm and calf circumferences) and correlate the nutritional parameters to severity of cancer and histopathology. The nutritional status of 73 cases of primary lung cancer was evaluated by anthropometric parameters, MNA test and impedencemetrie Results: According to body mass index (BMI), malnutrition, overweight and obesity were noted in 34,2%, 13,7% and 5,5%. According to BMI, free-fat mass index (FFMI) and fat mass index (FMI), the investigations occurred malnutrition and depletion of muscle in respectively 19,2% and 23,3% of cases. Fat depletion was noted in 21,9%. Overweight and obesity were detected in 6,8% and 5,5% of cases. Assessment by MNA, revealed that 28,7% of patients were already malnourished and 49,3% of patients were at risk of malnutrition. A significant correlation existed between the score of MNA and arm and calf circumferences, FFMI and FMI. FMI was significantly lower in group of patients with small lung carcinoma. Only FFMI allows early detection of malnutrition in cancer patients overestimated by measuring BMI and arm circumference was the better indicator of depletion of muscle.

  14. Clinical applications of textural analysis in non-small cell lung cancer.

    Science.gov (United States)

    Phillips, Iain; Ajaz, Mazhar; Ezhil, Veni; Prakash, Vineet; Alobaidli, Sheaka; McQuaid, Sarah J; South, Christopher; Scuffham, James; Nisbet, Andrew; Evans, Philip

    2018-01-01

    Lung cancer is the leading cause of cancer mortality worldwide. Treatment pathways include regular cross-sectional imaging, generating large data sets which present intriguing possibilities for exploitation beyond standard visual interpretation. This additional data mining has been termed "radiomics" and includes semantic and agnostic approaches. Textural analysis (TA) is an example of the latter, and uses a range of mathematically derived features to describe an image or region of an image. Often TA is used to describe a suspected or known tumour. TA is an attractive tool as large existing image sets can be submitted to diverse techniques for data processing, presentation, interpretation and hypothesis testing with annotated clinical outcomes. There is a growing anthology of published data using different TA techniques to differentiate between benign and malignant lung nodules, differentiate tissue subtypes of lung cancer, prognosticate and predict outcome and treatment response, as well as predict treatment side effects and potentially aid radiotherapy planning. The aim of this systematic review is to summarize the current published data and understand the potential future role of TA in managing lung cancer.

  15. Transbronchial Lung Cryobiopsy and Video-assisted Thoracoscopic Lung Biopsy in the Diagnosis of Diffuse Parenchymal Lung Disease. A Meta-analysis of Diagnostic Test Accuracy.

    Science.gov (United States)

    Iftikhar, Imran H; Alghothani, Lana; Sardi, Alejandro; Berkowitz, David; Musani, Ali I

    2017-07-01

    Transbronchial lung cryobiopsy is increasingly being used for the assessment of diffuse parenchymal lung diseases. Several studies have shown larger biopsy samples and higher yields compared with conventional transbronchial biopsies. However, the higher risk of bleeding and other complications has raised concerns for widespread use of this modality. To study the diagnostic accuracy and safety profile of transbronchial lung cryobiopsy and compare with video-assisted thoracoscopic surgery (VATS) by reviewing available evidence from the literature. Medline and PubMed were searched from inception until December 2016. Data on diagnostic performance were abstracted by constructing two-by-two contingency tables for each study. Data on a priori selected safety outcomes were collected. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of transbronchial lung cryobiopsy were 83.7% (76.9-88.8%), 87% (85-89%), and 57% (40-73%), respectively. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of VATS were 92.7% (87.6-95.8%), 91.0% (89-92%), and 58% (31-81%), respectively. The incidence of grade 2 (moderate to severe) endobronchial bleeding after transbronchial lung cryobiopsy and of post-procedural pneumothorax was 4.9% (2.2-10.7%) and 9.5% (5.9-14.9%), respectively. Although the diagnostic test accuracy measures of transbronchial lung cryobiopsy lag behind those of VATS, with an acceptable safety profile and potential cost savings, the former could be considered as an alternative in the evaluation of patients with diffuse parenchymal lung diseases.

  16. A probability index for surface zonda wind occurrence at Mendoza city through vertical sounding principal components analysis

    Science.gov (United States)

    Otero, Federico; Norte, Federico; Araneo, Diego

    2018-01-01

    The aim of this work is to obtain an index for predicting the probability of occurrence of zonda event at surface level from sounding data at Mendoza city, Argentine. To accomplish this goal, surface zonda wind events were previously found with an objective classification method (OCM) only considering the surface station values. Once obtained the dates and the onset time of each event, the prior closest sounding for each event was taken to realize a principal component analysis (PCA) that is used to identify the leading patterns of the vertical structure of the atmosphere previously to a zonda wind event. These components were used to construct the index model. For the PCA an entry matrix of temperature ( T) and dew point temperature (Td) anomalies for the standard levels between 850 and 300 hPa was build. The analysis yielded six significant components with a 94 % of the variance explained and the leading patterns of favorable weather conditions for the development of the phenomenon were obtained. A zonda/non-zonda indicator c can be estimated by a logistic multiple regressions depending on the PCA component loadings, determining a zonda probability index \\widehat{c} calculable from T and Td profiles and it depends on the climatological features of the region. The index showed 74.7 % efficiency. The same analysis was performed by adding surface values of T and Td from Mendoza Aero station increasing the index efficiency to 87.8 %. The results revealed four significantly correlated PCs with a major improvement in differentiating zonda cases and a reducing of the uncertainty interval.

  17. A Bayesian analysis of trends in ozone sounding data series from 9 Nordic stations

    Science.gov (United States)

    Christiansen, Bo; Jepsen, Nis; Larsen, Niels; Korsholm, Ulrik S.

    2016-04-01

    Ozone soundings from 9 Nordic stations have been homogenized and interpolated to standard pressure levels. The different stations have very different data coverage; the longest period with data is from the end of the 1980ies to 2013. We apply a model which includes both low-frequency variability in form of a polynomial, an annual cycle with harmonics, the possibility for low-frequency variability in the annual amplitude and phasing, and either white noise or AR1 noise. The fitting of the parameters is performed with a Bayesian approach not only giving the posterior mean values but also credible intervals. We find that all stations agree on an well-defined annual cycle in the free troposphere with a relatively confined maximum in the early summer. Regarding the low-frequency variability we find that Scoresbysund, Ny Aalesund, and Sodankyla show similar structures with a maximum near 2005 followed by a decrease. However, these results are only weakly significant. A significant change in the amplitude of the annual cycle was only found for Ny Aalesund. Here the peak-to-peak amplitude changes from 0.9 to 0.8 mhPa between 1995-2000 and 2007-2012. The results are shown to be robust to the different settings of the model parameters (order of the polynomial, number of harmonics in the annual cycle, type of noise, etc). The results are also shown to be characteristic for all pressure levels in the free troposphere.

  18. PREFACE: Aerodynamic sound Aerodynamic sound

    Science.gov (United States)

    Akishita, Sadao

    2010-02-01

    The modern theory of aerodynamic sound originates from Lighthill's two papers in 1952 and 1954, as is well known. I have heard that Lighthill was motivated in writing the papers by the jet-noise emitted by the newly commercialized jet-engined airplanes at that time. The technology of aerodynamic sound is destined for environmental problems. Therefore the theory should always be applied to newly emerged public nuisances. This issue of Fluid Dynamics Research (FDR) reflects problems of environmental sound in present Japanese technology. The Japanese community studying aerodynamic sound has held an annual symposium since 29 years ago when the late Professor S Kotake and Professor S Kaji of Teikyo University organized the symposium. Most of the Japanese authors in this issue are members of the annual symposium. I should note the contribution of the two professors cited above in establishing the Japanese community of aerodynamic sound research. It is my pleasure to present the publication in this issue of ten papers discussed at the annual symposium. I would like to express many thanks to the Editorial Board of FDR for giving us the chance to contribute these papers. We have a review paper by T Suzuki on the study of jet noise, which continues to be important nowadays, and is expected to reform the theoretical model of generating mechanisms. Professor M S Howe and R S McGowan contribute an analytical paper, a valuable study in today's fluid dynamics research. They apply hydrodynamics to solve the compressible flow generated in the vocal cords of the human body. Experimental study continues to be the main methodology in aerodynamic sound, and it is expected to explore new horizons. H Fujita's study on the Aeolian tone provides a new viewpoint on major, longstanding sound problems. The paper by M Nishimura and T Goto on textile fabrics describes new technology for the effective reduction of bluff-body noise. The paper by T Sueki et al also reports new technology for the

  19. A Healthy Dietary Pattern Reduces Lung Cancer Risk: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Yanlai Sun

    2016-03-01

    Full Text Available Background: Diet and nutrients play an important role in cancer development and progress; a healthy dietary pattern has been found to be associated with several types of cancer. However, the association between a healthy eating pattern and lung cancer risk is still unclear. Objective: Therefore, we conducted a systematic review with meta-analysis to evaluate whether a healthy eating pattern might reduce lung cancer risk. Methods: We identified relevant studies from the PubMed and Embase databases up to October 2015, and the relative risks were extracted and combined by the fixed-effects model when no substantial heterogeneity was observed; otherwise, the random-effects model was employed. Subgroup and publication bias analyses were also performed. Results: Finally, eight observational studies were included in the meta-analysis. The pooled relative risk of lung cancer for the highest vs. lowest category of healthy dietary pattern was 0.81 (95% confidence interval, CI: 0.75–0.86, and no significant heterogeneity was detected. The relative risks (RRs for non-smokers, former smokers and current smokers were 0.89 (95% CI: 0.63–1.27, 0.74 (95% CI: 0.62–0.89 and 0.86 (95% CI: 0.79–0.93, respectively. The results remained stable in subgroup analyses by other confounders and sensitivity analysis. Conclusions: The results of our meta-analysis suggest that a healthy dietary pattern is associated with a lower lung cancer risk, and they provide more beneficial evidence for changing the diet pattern in the general population.

  20. A Healthy Dietary Pattern Reduces Lung Cancer Risk: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Sun, Yanlai; Li, Zhenxiang; Li, Jianning; Li, Zengjun; Han, Jianjun

    2016-03-04

    Diet and nutrients play an important role in cancer development and progress; a healthy dietary pattern has been found to be associated with several types of cancer. However, the association between a healthy eating pattern and lung cancer risk is still unclear. Therefore, we conducted a systematic review with meta-analysis to evaluate whether a healthy eating pattern might reduce lung cancer risk. We identified relevant studies from the PubMed and Embase databases up to October 2015, and the relative risks were extracted and combined by the fixed-effects model when no substantial heterogeneity was observed; otherwise, the random-effects model was employed. Subgroup and publication bias analyses were also performed. Finally, eight observational studies were included in the meta-analysis. The pooled relative risk of lung cancer for the highest vs. lowest category of healthy dietary pattern was 0.81 (95% confidence interval, CI: 0.75-0.86), and no significant heterogeneity was detected. The relative risks (RRs) for non-smokers, former smokers and current smokers were 0.89 (95% CI: 0.63-1.27), 0.74 (95% CI: 0.62-0.89) and 0.86 (95% CI: 0.79-0.93), respectively. The results remained stable in subgroup analyses by other confounders and sensitivity analysis. The results of our meta-analysis suggest that a healthy dietary pattern is associated with a lower lung cancer risk, and they provide more beneficial evidence for changing the diet pattern in the general population.

  1. Large-scale association analysis identifies new lung cancer susceptibility loci and heterogeneity in genetic susceptibility across histological subtypes

    Science.gov (United States)

    McKay, James D.; Hung, Rayjean J.; Han, Younghun; Zong, Xuchen; Carreras-Torres, Robert; Christiani, David C.; Caporaso, Neil E.; Johansson, Mattias; Xiao, Xiangjun; Li, Yafang; Byun, Jinyoung; Dunning, Alison; Pooley, Karen A.; Qian, David C.; Ji, Xuemei; Liu, Geoffrey; Timofeeva, Maria N.; Bojesen, Stig E.; Wu, Xifeng; Le Marchand, Loic; Albanes, Demetrios; Bickeböller, Heike; Aldrich, Melinda C.; Bush, William S.; Tardon, Adonina; Rennert, Gad; Teare, M. Dawn; Field, John K.; Kiemeney, Lambertus A.; Lazarus, Philip; Haugen, Aage; Lam, Stephen; Schabath, Matthew B.; Andrew, Angeline S.; Shen, Hongbing; Hong, Yun-Chul; Yuan, Jian-Min; Bertazzi, Pier Alberto; Pesatori, Angela C.; Ye, Yuanqing; Diao, Nancy; Su, Li; Zhang, Ruyang; Brhane, Yonathan; Leighl, Natasha; Johansen, Jakob S.; Mellemgaard, Anders; Saliba, Walid; Haiman, Christopher A.; Wilkens, Lynne R.; Fernandez-Somoano, Ana; Fernandez-Tardon, Guillermo; van der Heijden, Henricus F.M.; Kim, Jin Hee; Dai, Juncheng; Hu, Zhibin; Davies, Michael PA; Marcus, Michael W.; Brunnström, Hans; Manjer, Jonas; Melander, Olle; Muller, David C.; Overvad, Kim; Trichopoulou, Antonia; Tumino, Rosario; Doherty, Jennifer A.; Barnett, Matt P.; Chen, Chu; Goodman, Gary E.; Cox, Angela; Taylor, Fiona; Woll, Penella; Brüske, Irene; Wichmann, H.-Erich; Manz, Judith; Muley, Thomas R.; Risch, Angela; Rosenberger, Albert; Grankvist, Kjell; Johansson, Mikael; Shepherd, Frances A.; Tsao, Ming-Sound; Arnold, Susanne M.; Haura, Eric B.; Bolca, Ciprian; Holcatova, Ivana; Janout, Vladimir; Kontic, Milica; Lissowska, Jolanta; Mukeria, Anush; Ognjanovic, Simona; Orlowski, Tadeusz M.; Scelo, Ghislaine; Swiatkowska, Beata; Zaridze, David; Bakke, Per; Skaug, Vidar; Zienolddiny, Shanbeh; Duell, Eric J.; Butler, Lesley M.; Koh, Woon-Puay; Gao, Yu-Tang; Houlston, Richard S.; McLaughlin, John; Stevens, Victoria L.; Joubert, Philippe; Lamontagne, Maxime; Nickle, David C.; Obeidat, Ma’en; Timens, Wim; Zhu, Bin; Song, Lei; Kachuri, Linda; Artigas, María Soler; Tobin, Martin D.; Wain, Louise V.; Rafnar, Thorunn; Thorgeirsson, Thorgeir E.; Reginsson, Gunnar W.; Stefansson, Kari; Hancock, Dana B.; Bierut, Laura J.; Spitz, Margaret R.; Gaddis, Nathan C.; Lutz, Sharon M.; Gu, Fangyi; Johnson, Eric O.; Kamal, Ahsan; Pikielny, Claudio; Zhu, Dakai; Lindströem, Sara; Jiang, Xia; Tyndale, Rachel F.; Chenevix-Trench, Georgia; Beesley, Jonathan; Bossé, Yohan; Chanock, Stephen; Brennan, Paul; Landi, Maria Teresa; Amos, Christopher I.

    2017-01-01

    Summary While several lung cancer susceptibility loci have been identified, much of lung cancer heritability remains unexplained. Here, 14,803 cases and 12,262 controls of European descent were genotyped on the OncoArray and combined with existing data for an aggregated GWAS analysis of lung cancer on 29,266 patients and 56,450 controls. We identified 18 susceptibility loci achieving genome wide significance, including 10 novel loci. The novel loci highlighted the striking heterogeneity in genetic susceptibility across lung cancer histological subtypes, with four loci associated with lung cancer overall and six with lung adenocarcinoma. Gene expression quantitative trait analysis (eQTL) in 1,425 normal lung tissues highlighted RNASET2, SECISBP2L and NRG1 as candidate genes. Other loci include genes such as a cholinergic nicotinic receptor, CHRNA2, and the telomere-related genes, OFBC1 and RTEL1. Further exploration of the target genes will continue to provide new insights into the etiology of lung cancer. PMID:28604730

  2. Large-scale association analysis identifies new lung cancer susceptibility loci and heterogeneity in genetic susceptibility across histological subtypes.

    Science.gov (United States)

    McKay, James D; Hung, Rayjean J; Han, Younghun; Zong, Xuchen; Carreras-Torres, Robert; Christiani, David C; Caporaso, Neil E; Johansson, Mattias; Xiao, Xiangjun; Li, Yafang; Byun, Jinyoung; Dunning, Alison; Pooley, Karen A; Qian, David C; Ji, Xuemei; Liu, Geoffrey; Timofeeva, Maria N; Bojesen, Stig E; Wu, Xifeng; Le Marchand, Loic; Albanes, Demetrios; Bickeböller, Heike; Aldrich, Melinda C; Bush, William S; Tardon, Adonina; Rennert, Gad; Teare, M Dawn; Field, John K; Kiemeney, Lambertus A; Lazarus, Philip; Haugen, Aage; Lam, Stephen; Schabath, Matthew B; Andrew, Angeline S; Shen, Hongbing; Hong, Yun-Chul; Yuan, Jian-Min; Bertazzi, Pier Alberto; Pesatori, Angela C; Ye, Yuanqing; Diao, Nancy; Su, Li; Zhang, Ruyang; Brhane, Yonathan; Leighl, Natasha; Johansen, Jakob S; Mellemgaard, Anders; Saliba, Walid; Haiman, Christopher A; Wilkens, Lynne R; Fernandez-Somoano, Ana; Fernandez-Tardon, Guillermo; van der Heijden, Henricus F M; Kim, Jin Hee; Dai, Juncheng; Hu, Zhibin; Davies, Michael P A; Marcus, Michael W; Brunnström, Hans; Manjer, Jonas; Melander, Olle; Muller, David C; Overvad, Kim; Trichopoulou, Antonia; Tumino, Rosario; Doherty, Jennifer A; Barnett, Matt P; Chen, Chu; Goodman, Gary E; Cox, Angela; Taylor, Fiona; Woll, Penella; Brüske, Irene; Wichmann, H-Erich; Manz, Judith; Muley, Thomas R; Risch, Angela; Rosenberger, Albert; Grankvist, Kjell; Johansson, Mikael; Shepherd, Frances A; Tsao, Ming-Sound; Arnold, Susanne M; Haura, Eric B; Bolca, Ciprian; Holcatova, Ivana; Janout, Vladimir; Kontic, Milica; Lissowska, Jolanta; Mukeria, Anush; Ognjanovic, Simona; Orlowski, Tadeusz M; Scelo, Ghislaine; Swiatkowska, Beata; Zaridze, David; Bakke, Per; Skaug, Vidar; Zienolddiny, Shanbeh; Duell, Eric J; Butler, Lesley M; Koh, Woon-Puay; Gao, Yu-Tang; Houlston, Richard S; McLaughlin, John; Stevens, Victoria L; Joubert, Philippe; Lamontagne, Maxime; Nickle, David C; Obeidat, Ma'en; Timens, Wim; Zhu, Bin; Song, Lei; Kachuri, Linda; Artigas, María Soler; Tobin, Martin D; Wain, Louise V; Rafnar, Thorunn; Thorgeirsson, Thorgeir E; Reginsson, Gunnar W; Stefansson, Kari; Hancock, Dana B; Bierut, Laura J; Spitz, Margaret R; Gaddis, Nathan C; Lutz, Sharon M; Gu, Fangyi; Johnson, Eric O; Kamal, Ahsan; Pikielny, Claudio; Zhu, Dakai; Lindströem, Sara; Jiang, Xia; Tyndale, Rachel F; Chenevix-Trench, Georgia; Beesley, Jonathan; Bossé, Yohan; Chanock, Stephen; Brennan, Paul; Landi, Maria Teresa; Amos, Christopher I

    2017-07-01

    Although several lung cancer susceptibility loci have been identified, much of the heritability for lung cancer remains unexplained. Here 14,803 cases and 12,262 controls of European descent were genotyped on the OncoArray and combined with existing data for an aggregated genome-wide association study (GWAS) analysis of lung cancer in 29,266 cases and 56,450 controls. We identified 18 susceptibility loci achieving genome-wide significance, including 10 new loci. The new loci highlight the striking heterogeneity in genetic susceptibility across the histological subtypes of lung cancer, with four loci associated with lung cancer overall and six loci associated with lung adenocarcinoma. Gene expression quantitative trait locus (eQTL) analysis in 1,425 normal lung tissue samples highlights RNASET2, SECISBP2L and NRG1 as candidate genes. Other loci include genes such as a cholinergic nicotinic receptor, CHRNA2, and the telomere-related genes OFBC1 and RTEL1. Further exploration of the target genes will continue to provide new insights into the etiology of lung cancer.

  3. A combined analysis of North American case-control studies of residential radon and lung cancer.

    Science.gov (United States)

    Krewski, Daniel; Lubin, Jay H; Zielinski, Jan M; Alavanja, Michael; Catalan, Vanessa S; Field, R William; Klotz, Judith B; Létourneau, Ernest G; Lynch, Charles F; Lyon, Joseph L; Sandler, Dale P; Schoenberg, Janet B; Steck, Daniel J; Stolwijk, Jan A; Weinberg, Clarice; Wilcox, Homer B

    2006-04-01

    Cohort studies have consistently shown underground miners exposed to high levels of radon to be at excess risk of lung cancer, and extrapolations based on those results indicate that residential radon may be responsible for nearly 10-15% of all lung cancer deaths per year in the United States. However, case-control studies of residential radon and lung cancer have provided ambiguous evidence of radon lung cancer risks. Regardless, alpha-particle emissions from the short-lived radioactive radon decay products can damage cellular DNA. The possibility that a demonstrated lung carcinogen may be present in large numbers of homes raises a serious public health concern. Thus, a systematic analysis of pooled data from all North American residential radon studies was undertaken to provide a more direct characterization of the public health risk posed by prolonged radon exposure. To evaluate the risk associated with prolonged residential radon exposure, a combined analysis of the primary data from seven large scale case-control studies of residential radon and lung cancer risk was conducted. The combined data set included a total of 4081 cases and 5281 controls, representing the largest aggregation of data on residential radon and lung cancer conducted to date. Residential radon concentrations were determined primarily by a-track detectors placed in the living areas of homes of the study subjects in order to obtain an integrated 1-yr average radon concentration in indoor air. Conditional likelihood regression was used to estimate the excess risk of lung cancer due to residential radon exposure, with adjustment for attained age, sex, study, smoking factors, residential mobility, and completeness of radon measurements. Although the main analyses were based on the combined data set as a whole, we also considered subsets of the data considered to have more accurate radon dosimetry. This included a subset of the data involving 3662 cases and 4966 controls with a-track radon

  4. Automation method to identify the geological structure of seabed using spatial statistic analysis of echo sounding data

    Science.gov (United States)

    Kwon, O.; Kim, W.; Kim, J.

    2017-12-01

    Recently construction of subsea tunnel has been increased globally. For safe construction of subsea tunnel, identifying the geological structure including fault at design and construction stage is more than important. Then unlike the tunnel in land, it's very difficult to obtain the data on geological structure because of the limit in geological survey. This study is intended to challenge such difficulties in a way of developing the technology to identify the geological structure of seabed automatically by using echo sounding data. When investigation a potential site for a deep subsea tunnel, there is the technical and economical limit with borehole of geophysical investigation. On the contrary, echo sounding data is easily obtainable while information reliability is higher comparing to above approaches. This study is aimed at developing the algorithm that identifies the large scale of geological structure of seabed using geostatic approach. This study is based on theory of structural geology that topographic features indicate geological structure. Basic concept of algorithm is outlined as follows; (1) convert the seabed topography to the grid data using echo sounding data, (2) apply the moving window in optimal size to the grid data, (3) estimate the spatial statistics of the grid data in the window area, (4) set the percentile standard of spatial statistics, (5) display the values satisfying the standard on the map, (6) visualize the geological structure on the map. The important elements in this study include optimal size of moving window, kinds of optimal spatial statistics and determination of optimal percentile standard. To determine such optimal elements, a numerous simulations were implemented. Eventually, user program based on R was developed using optimal analysis algorithm. The user program was designed to identify the variations of various spatial statistics. It leads to easy analysis of geological structure depending on variation of spatial statistics

  5. An analysis of the potential for oil spill effects on the herring population of Prince William Sound, Alaska

    International Nuclear Information System (INIS)

    Pearson, W.H.; Elston, R.A.; Bienert, R.W.; Drum, A.S.; Antrim, L.D.

    1996-01-01

    The impact of the Exxon Valdez oil spill on the herring population in Prince William Sound, was studied. Following the incident in 1989, there was no commercial harvest of herring. However, 1990 through 1992 proved to have above average, record harvests. This was followed by a dramatic decline in 1993 which was generally attributed to the oil spill. An examination of the scientific data was conducted. The main hypotheses for the decline were tested. These hypotheses attributed the decline to: (1) the oil spill itself, (2) a combination of increasing herring biomass and decreasing food supply, (3) disease, and (4) other natural stochastic processes. Based on the review of the data and the analysis of the four alternative hypotheses, it was concluded that the population decline of 1993 was the result of a combination of increasing herring biomass and decreasing food supply. No connection to the Exxon Valdez incident was evident. 22 refs., 6 figs

  6. A comparative analysis of bleached and sound enamel structure through scanning electron microscopy and atomic force microscopy

    International Nuclear Information System (INIS)

    Saleem, A.; Kaleem, M.; Anwar, R.

    2015-01-01

    To analyze the effects of bleaching agent on enamel structure and to characterize the morphological and chemical changes in enamel due to bleaching. Study Design: Experimental study. Place and Duration of Study: School of Chemical and Material Engineering (SCME), NUST Islamabad from Feb to May 2013. Materials and Methods: Ten recently extracted pre molars between the 12-22 years age group were randomly assigned into two groups. Group one was a non-bleached control group with sound enamel. Group two was bleached with Everbrite In office tooth whitening system after specimen preparation, surface morphology was observed under SEM (scanned electron microscope) and AFM (Atomic force microscope). Results: The detrimental effects of hydrogen per-oxide on enamel were evident in bleached specimens under SEM, and AFM analysis. Conclusion: There were significant surface alterations found in the bleached specimens as compared to control group. However salivary buffering potentials could overcome the demineralizing effect of bleaching gel. (author)

  7. Analysis on Lung Cancer Survival from 2001 to 2007 in Qidong, China

    Directory of Open Access Journals (Sweden)

    Jian ZHU

    2011-01-01

    Full Text Available Background and objective Lung cancer is one of the most important malignancies in China. Survival rates of lung cancer on the population-based cancer registry for the years 2001-2007 in Qidong were analysed in order to provide the basis for the prognosis assessment and the control of this cancer. Methods Total 4,451 registered lung cancer cases was followed up to December 31st, 2009. Death certificates only (DCO cases were excluded, leaving 4,382 cases for survival analysis. Cumulative observed survival rate (OS and relative survival rate (RS were calculated using Hakulinen’s method performed by the SURV 3.01 software developed at the Finnish Cancer Registry. Results The 1-, 3-, and 5-year OS rates were 23.73%, 11.89%, 10.01%, and the RS rates were 24.86%, 13.69%, 12.73%, respectively. The 1-, 3-, and 5-year RS of males vs females were 23.70% vs 27.89%, 12.58% vs 16.53%, and 11.73% vs 15.21%, respectively, with statisitically significant differences (χ2=13.77, P=0.032. RS of age groups of 15-34, 35-44, 45-54, 55-64, 65-74 and 75+ were 35.46%, 17.66%, 11.97%, 13.49%, 10.61%, 15.14%, respectively. Remarkable improvement could be seen for the 5-year RS in this setting if compared with that for the years 1972-2000. Conclusion The lung cancer survival outcomes in Qidong have been improved gradually for the past decades. Further measures on the prevention, diagnosis and treatment of lung cancer should be taken.

  8. Exhaled breath analysis for lung cancer detection using ion mobility spectrometry.

    Directory of Open Access Journals (Sweden)

    Hiroshi Handa

    Full Text Available Conventional methods for lung cancer detection including computed tomography (CT and bronchoscopy are expensive and invasive. Thus, there is still a need for an optimal lung cancer detection technique.The exhaled breath of 50 patients with lung cancer histologically proven by bronchoscopic biopsy samples (32 adenocarcinomas, 10 squamous cell carcinomas, 8 small cell carcinomas, were analyzed using ion mobility spectrometry (IMS and compared with 39 healthy volunteers. As a secondary assessment, we compared adenocarcinoma patients with and without epidermal growth factor receptor (EGFR mutation.A decision tree algorithm could separate patients with lung cancer including adenocarcinoma, squamous cell carcinoma and small cell carcinoma. One hundred-fifteen separated volatile organic compound (VOC peaks were analyzed. Peak-2 noted as n-Dodecane using the IMS database was able to separate values with a sensitivity of 70.0% and a specificity of 89.7%. Incorporating a decision tree algorithm starting with n-Dodecane, a sensitivity of 76% and specificity of 100% was achieved. Comparing VOC peaks between adenocarcinoma and healthy subjects, n-Dodecane was able to separate values with a sensitivity of 81.3% and a specificity of 89.7%. Fourteen patients positive for EGFR mutation displayed a significantly higher n-Dodecane than for the 14 patients negative for EGFR (p<0.01, with a sensitivity of 85.7% and a specificity of 78.6%.In this prospective study, VOC peak patterns using a decision tree algorithm were useful in the detection of lung cancer. Moreover, n-Dodecane analysis from adenocarcinoma patients might be useful to discriminate the EGFR mutation.

  9. Speech-language pathologists' practices regarding assessment, analysis, target selection, intervention, and service delivery for children with speech sound disorders.

    Science.gov (United States)

    Mcleod, Sharynne; Baker, Elise

    2014-01-01

    A survey of 231 Australian speech-language pathologists (SLPs) was undertaken to describe practices regarding assessment, analysis, target selection, intervention, and service delivery for children with speech sound disorders (SSD). The participants typically worked in private practice, education, or community health settings and 67.6% had a waiting list for services. For each child, most of the SLPs spent 10-40 min in pre-assessment activities, 30-60 min undertaking face-to-face assessments, and 30-60 min completing paperwork after assessments. During an assessment SLPs typically conducted a parent interview, single-word speech sampling, collected a connected speech sample, and used informal tests. They also determined children's stimulability and estimated intelligibility. With multilingual children, informal assessment procedures and English-only tests were commonly used and SLPs relied on family members or interpreters to assist. Common analysis techniques included determination of phonological processes, substitutions-omissions-distortions-additions (SODA), and phonetic inventory. Participants placed high priority on selecting target sounds that were stimulable, early developing, and in error across all word positions and 60.3% felt very confident or confident selecting an appropriate intervention approach. Eight intervention approaches were frequently used: auditory discrimination, minimal pairs, cued articulation, phonological awareness, traditional articulation therapy, auditory bombardment, Nuffield Centre Dyspraxia Programme, and core vocabulary. Children typically received individual therapy with an SLP in a clinic setting. Parents often observed and participated in sessions and SLPs typically included siblings and grandparents in intervention sessions. Parent training and home programs were more frequently used than the group therapy. Two-thirds kept up-to-date by reading journal articles monthly or every 6 months. There were many similarities with

  10. Sound Visualisation

    OpenAIRE

    Dolenc, Peter

    2013-01-01

    This thesis contains a description of a construction of subwoofer case that has an extra functionality of being able to produce special visual effects and display visualizations that match the currently playing sound. For this reason, multiple lighting elements made out of LED (Light Emitting Diode) diodes were installed onto the subwoofer case. The lighting elements are controlled by dedicated software that was also developed. The software runs on STM32F4-Discovery evaluation board inside a ...

  11. Prognostic value of lncRNAs in lung carcinoma: a meta-analysis.

    Science.gov (United States)

    Fan, Fan; Zhu, Zhengqiu; Gao, Chao; Liu, Yun; Wang, Baoqing; Wang, Ziquan; Feng, Jifeng

    2017-10-10

    Many different long non-coding RNAs (lncRNAs) have been reported to be abnormally expressed in lung carcinoma and may thus serve as prognostic biomarkers for this disease. We conducted this meta-analysis, which included a total of 30 studies identified via searches of PubMed, Embase, Medline, and Web of Science and included 2912 patients from China (28), Germany (1), and Japan (1), to investigate the prognostic value of different lncRNAs in lung carcinoma. The results revealed that lncRNA transcription levels were significantly associated with overall survival in lung cancer patients (HR:1.46, 95% CI: 1.16-1.83, P = 0.000). However, lncRNA transcription levels were not associated with progression-free survival (PFS) (HR: 1.55, 95% CI: 0.50-4.80, P = 0.449). Further analysis showed that high lncRNA transcription levels were significantly associated with tumour-node-metastasis (TNM) stage (III/IV vs I/II: RR = 1.339, 95% CI: 1.046-1.716, P = 0.012), lymph node metastasis (positive vs negative: RR = 1.442, 95% CI: 1.103-1.885, P = 0.007), and distant metastasis (yes vs no: RR = 3.187,95% CI: 1.393-7.294, P = 0.006). Taken together, the results of our present meta-analysis revealed that lncRNAs may be useful prognostic markers for lung carcinoma and may also have value as biomarkers for TNM stage, lymph node metastasis and distant metastasis.

  12. Bronchoalveolar lavage analysis, gallium-67 lung scanning and soluble interleukin-2 receptor levels in asbestos exposure

    International Nuclear Information System (INIS)

    Delclos, G.L.; Flitcraft, D.G.; Brousseau, K.P.; Windsor, N.T.; Nelson, D.L.; Wilson, R.K.; Lawrence, E.C.

    1989-01-01

    This study examined different markers of lung immunologic and inflammatory responses to previous asbestos exposure. We performed bronchoalveolar lavage (BAL) and gallium-67 ( 67 Ga) lung scans and measured serum and BAL soluble interleukin-2 receptor (IL-2R) and angiotensin-converting enzyme (SACE) levels in 32 subjects with a history of significant asbestos exposure, 14 without (EXP) and 18 with (ASB) radiographic evidence of asbestosis. BAL analysis revealed increases in neutrophils in both ASB and EXP when compared to controls (P less than 0.01), which persisted after adjustment for smoking category. Although significant abnormalities of macrophage and total lymphocyte profiles were not found in the study population, lymphocyte subpopulation analysis revealed elevation of BAL T4/T8 ratios in the entire study group (ASB + EXP) when compared to controls (P less than 0.05), independent of smoking category. 67 Ga lung scan activity was increased in 56% of ASB and in 36% of EXP: no correlations between positive scans and different radiological and functional parameters could be found. There was no significant elevation of mean SACE, serum, or BAL IL-2R levels in any of the study categories. These data suggest that asbestos exposure may be associated with parenchymal inflammation, even in the absence of clinical criteria for asbestosis. Abnormalities of gallium uptake and of BAL analysis reflect the clinically inapparent inflammation. The increased BAL T4/T8 ratios observed suggest that abnormal local pulmonary immunoregulation may play a role in the pathogenesis of asbestos-related lung diseases

  13. The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting

    International Nuclear Information System (INIS)

    Marques, Alda; Bruton, Anne; Barney, Anna

    2009-01-01

    Lung sounds provide useful information for assessing and monitoring respiratory patients, but standard auscultation is subjective. Computer aided lung sound analysis (CALSA) enables the quantification and characterisation of added lung sounds (e.g. crackles). At present, little is known about the reliability of these sound characteristics. Therefore, the aim of this study was to explore the reliability of crackle initial deflection width (IDW) and two-cycle deflection (2CD) in a clinical population. Fifty-four subjects (37 bronchiectasis, 17 cystic fibrosis) were recruited from out-patient clinics. Three repeated lung sound recordings were taken at seven anatomical sites with a digital stethoscope connected to a laptop computer. The intra-subject reliability of crackle IDW and 2CD was found to be 'good' to 'excellent', estimated by the analysis of variance, intraclass correlation coefficient (IDW 0.76;0.85, 2CD 0.83;0.94), Bland and Altman 95% limits of agreement (IDW −0.50;0.47 ms, 2CD −2.12;1.87 ms) and smallest real difference (IDW 0.30;0.66 ms, 2CD 1.57;2.42 ms). Crackle 2CD was found to be more reliable than IDW. It is concluded that crackle IDW and 2CD characterized by CALSA have good test–retest reliability. This technique requires further evaluation since CALSA has potential to diagnose or monitor respiratory conditions, and provide an objective physiological measure for respiratory interventions

  14. 99Tcm-MIBI imaging in diagnosing benign/malign pulmonary disease and analysis of lung cancer DNA content

    International Nuclear Information System (INIS)

    Feng Yanlin; Tan Jiaju; Yang Jie; Zhu Zheng; Yu Fengwen; He Xiaohong; Huang Kemin; Yuan Baihong; Su Shaodi

    2002-01-01

    Objective: To evaluate the value of 99 Tc m -methoxyisobutylisonitrile (MIBI) lung imaging in diagnosing benign/malign pulmonary disease and the relation of 99 Tc m -MIBI uptake ratio (UR) with lung cancer DNA content. Methods: Early and delay imaging were performed on 27 cases of benign lung disease and 46 cases of malign lung disease. Visual analysis of the images and T/N uptake ratio measurement were performed on every case. Cancer cell DNA content and DNA index (DI) were measured in 24 cases of malign pulmonary disease. Results: The delay phase UR was 1.13 ± 0.19 in benign disease group, and the delay phase UR was 1.45 ± 0.21 in malign disease group (t6.51, P 99 Tc m -MIBI is not an ideal imaging agent for differentiating pulmonary benign/malign disease. Lung cancer DNA content may be reflected by delay phase UR

  15. Basic semantics of product sounds

    NARCIS (Netherlands)

    Özcan Vieira, E.; Van Egmond, R.

    2012-01-01

    Product experience is a result of sensory and semantic experiences with product properties. In this paper, we focus on the semantic attributes of product sounds and explore the basic components for product sound related semantics using a semantic differential paradigmand factor analysis. With two

  16. A comparative numerical analysis of linear and nonlinear aerodynamic sound generation by vortex disturbances in homentropic constant shear flows

    International Nuclear Information System (INIS)

    Hau, Jan-Niklas; Oberlack, Martin; Chagelishvili, George; Khujadze, George; Tevzadze, Alexander

    2015-01-01

    plane, which results in highly directional linear sound radiation, whereas the nonlinearly generated waves are almost omni-directional. As part of this analysis, we compare the effectiveness of the linear and nonlinear mechanisms of wave generation within the range of validity of the rapid distortion theory and show the dominance of the linear aerodynamic sound generation. Finally, topological differences between the linear source term of the acoustic analogy equation and of the anisotropic non-normality induced linear mechanism of wave generation are found

  17. Differentiating invasive and pre-invasive lung cancer by quantitative analysis of histopathologic images

    Science.gov (United States)

    Zhou, Chuan; Sun, Hongliu; Chan, Heang-Ping; Chughtai, Aamer; Wei, Jun; Hadjiiski, Lubomir; Kazerooni, Ella

    2018-02-01

    We are developing automated radiopathomics method for diagnosis of lung nodule subtypes. In this study, we investigated the feasibility of using quantitative methods to analyze the tumor nuclei and cytoplasm in pathologic wholeslide images for the classification of pathologic subtypes of invasive nodules and pre-invasive nodules. We developed a multiscale blob detection method with watershed transform (MBD-WT) to segment the tumor cells. Pathomic features were extracted to characterize the size, morphology, sharpness, and gray level variation in each segmented nucleus and the heterogeneity patterns of tumor nuclei and cytoplasm. With permission of the National Lung Screening Trial (NLST) project, a data set containing 90 digital haematoxylin and eosin (HE) whole-slide images from 48 cases was used in this study. The 48 cases contain 77 regions of invasive subtypes and 43 regions of pre-invasive subtypes outlined by a pathologist on the HE images using the pathological tumor region description provided by NLST as reference. A logistic regression model (LRM) was built using leave-one-case-out resampling and receiver operating characteristic (ROC) analysis for classification of invasive and pre-invasive subtypes. With 11 selected features, the LRM achieved a test area under the ROC curve (AUC) value of 0.91+/-0.03. The results demonstrated that the pathologic invasiveness of lung adenocarcinomas could be categorized with high accuracy using pathomics analysis.

  18. A new application of Bull's eye analysis to lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yasui, Kotaro; Kohno, Yoshihiro; Akaki, Shiro; Hasegawa, Mari; Nakagawa, Tomio; Simizu, Mitsuharu; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao.

    1990-01-01

    Technetium-99m macroaggregated albumin lung perfusion scintigraphy was performed and evaluated semiquantitatively by Bull's eye analysis in 24, including 7 with central pulmonary carcinoma, 3 with hypersensitivity pneumonitis (HP), 3 with diffuse panbronchiolitis (DPB) and 11 normal subjects. First, whole lung field was divided into three regions by three concentric circles. And then radial axes were projected from the center to define 36 sectors, 10 degree each. The counts of each sector was calculated and Bull's eye image and circumferential profile curve were displayed. The patient's map was compared with the lower limit of normal (mean-2 SD), and the extent score (ES) and the severity score (SS) were calculated. The ES was 0.25±0.12 in pulmonary carcinoma (n=7), 0.08±0.07 in HP (n=3), 0.06±0.04 in DPB (n=3). The SS was 26.39±15.17 in pulmonary carcinoma, 4.75±5.57 in HP, 4.29±3.67 in DPB. In one case of central pulmonary carcinoma, segmental perfusion defect was evaluated semiquantitatively by Bull's eye image and circumferential profile curve. And in one case of HP, the change of regional pulmonary blood flow could be followed easily using extent and severity map. This new application of Bull's eye analysis to lung perfusion scintigraphy might be useful to evaluate regional pulmonary blood flow. (author)

  19. Lung cancer mutation profile of EGFR, ALK, and KRAS: Meta-analysis and comparison of never and ever smokers.

    Science.gov (United States)

    Chapman, Aaron M; Sun, Kathie Y; Ruestow, Peter; Cowan, Dallas M; Madl, Amy K

    2016-12-01

    Lung cancer is the leading cause of cancer-related mortality. While the majority of lung cancers are associated with tobacco smoke, approximately 10-15% of U.S. lung cancers occur in never smokers. Evidence suggests that lung cancer in never smokers appears to be a distinct disease caused by driver mutations which are different than the genetic pathways observed with lung cancer in smokers. A meta-analysis of human epidemiologic data was conducted to evaluate the profile of common or therapy-targetable mutations in lung cancers of never and ever smokers. Epidemiologic studies (N=167) representing over 63,000 lung cancer cases were identified and used to calculate summary odds ratios for lung cancer in never and ever smokers containing gene mutations: EGFR, chromosomal rearrangements and fusion of EML4 and ALK, and KRAS. This analysis also considered the effect of histopathology, smoking status, sex, and ethnicity. There were significantly increased odds of presenting the EGFR and ALK-EML4 mutations in 1) adenocarcinomas compared to non-small cell lung cancer and 2) never smokers compared to ever smokers. The prevalence of EGFR mutations was higher in Asian women as compared to women of Caucasian/Mixed ethnicity. As the smoking history increased, there was a decreased odds for exhibiting the EGFR mutation, particularly for cases >30 pack-years. Compared to ever smokers, never smokers had a decreased odds of KRAS mutations among those of Caucasian/Mixed ethnicity (OR=0.22, 95% CI: 0.17-0.29) and those of Asian ethnicity (OR=0.39, 95% CI: 0.30-0.50). Our findings show that key driver mutations and several patient features are highly prevalent in lung cancers of never smokers. These associations may be helpful as patient demographic models are developed to predict successful outcomes of targeted therapeutic interventions NSCLC. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Spirometrically gated /sup 133/Xe ventilation imaging and phase analysis for assessment of regional lung function

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Tomio (Kanto Teishin Hospital, Tokyo (Japan))

    1984-10-01

    The purpose of this study is to develop the technique of performing spirometrically gated /sup 133/Xe ventilation imaging and to evaluate its clinical usefulness for the assessment of regional ventilatory function in various lung diseases. Patients rebreathed /sup 133/Xe gas through the system with constant rates signaled by a metronome. The trigger signals from the patients were recorded in a minicomputer for 60 respiratory cycles simultaneously with posterior lung images. Functional images (phase analysis images) indicating phase and amplitude of regional ventilation were constructed by the first harmonic Fourier analysis. Materials included 13 normal volunteers and patients with COPD (24), lung cancer (5), pulmonary embolism (4) and others (20). In normal controls, phase analysis images before respiratory motion correction revealed gradual decrease in amplitude from base to apex with uniform phase distribution. The amplitude and phase distribution after respiratory motion correction became even more uniform. In patients with COPD, phase analysis images showed asymmetrical and irregular amplitude distribution with non-uniform phase distribution. The standard deviation (S.D.) of phase histogram correlated well with FEVsub(1.0)% (r=0.71, p < 0.001) and down slope of flow-volume curve (r=0.55, p < 0.001), and less prominently with %VC (r=0.42, p < 0.01). Mean S.D. in patients with COPD (12.3 +- 6.5 degree, mean+-1 s.d.) was significantly larger than in normal controls (6.3 +- 1.5). Amplitude profile curve analysis revealed 83% sensitivity for the detection of abnormal spirometric respiratory function test. Data aquisition and processing of present method are rapid and easy to perform. The phase analysis of the gated ventilation images should prove useful in the clinical evaluation of patients with uneven ventilation such as COPD.

  1. Spirometrically gated 133Xe ventilation imaging and phase analysis for assessment of regional lung function

    International Nuclear Information System (INIS)

    Inoue, Tomio

    1984-01-01

    The purpose of this study is to develop the technique of performing spirometrically gated 133 Xe ventilation imaging and to evaluate its clinical usefulness for the assessmentof regional ventilatory function in various lung diseases. Patients rebreathe d 133 Xe gas through the system with constant rates signaled by a metronom. The trigger signals from the patients were recorded in a minicomputer for 60 respiratory cycles simultaneously with posterior lung images. Functional images (phase analysis images) indicating phase and amplitude of regional ventilation were constructed by the first harmonic Fourier analysis. Materials included 13 normal volunteers and patients with COPD (24), lung cancer (5), pulmonary embolism (4) and others (20). In normal controls, phase analysis images before respiratory motion correction revealed gradual decrease in amplitude from base to apex with uniform phase distribution. The amplitude and phase distribution after respiratory motion correction became even more uniform. In patients with COPD, phase analysis images showed asymmetrical and irregular amplitude distribution with non-uniform phase distribution. The standard deviation (S.D.) of phase histogram correlated well with FEVsub(1.0)% (r=0.71, p<0.001) and down slope of flowvolume curve (r=0.55, p<0.001), and less prominently with %VC (r=0.42, p<0.01). Mean S.D. in patients with COPD (12.3+-6.5 degree, mean+-1 s.d.) was significantly larger than in normal controls (6.3+-1.5). Amplitude profile curve analysis revealed 83% sensitivity for the detection of abnormal spirometric respiratory function test. Data aquisition and processing of present method are rapid and easy to perform. The phase analysis of the gated ventilation images should prove useful in the clinical evaluation of patients with uneven ventilation such as COPD. (J.P.N.)

  2. Reevaluation and reclassification of resected lung carcinomas originally diagnosed as squamous cell carcinoma using immunohistochemical analysis

    Science.gov (United States)

    Kadota, Kyuichi; Nitadori, Jun-ichi; Rekhtman, Natasha; Jones, David R.; Adusumilli, Prasad S.; Travis, William D.

    2015-01-01

    Currently, non-small cell lung carcinomas are primarily classified by light microscopy. However, recent studies have shown that poorly-differentiated tumors are more accurately classified by immunohistochemistry. In this study, we investigated the use of immunohistochemical analysis in reclassifying lung carcinomas that were originally diagnosed as squamous cell carcinoma. Tumor slides and blocks were available for histologic evaluation, and tissue microarrays were constructed from 480 patients with resected lung carcinomas originally diagnosed as squamous cell carcinoma between 1999 and 2009. Immunohistochemistry for p40, p63, thyroid transcription factor-1 (TTF-1; clone SPT24 and 8G7G3/1), Napsin A, Chromogranin A, Synaptophysin, and CD56 were performed. Staining intensity (weak, moderate, or strong) and distribution (focal or diffuse) were also recorded. Of all, 449 (93.5%) patients were confirmed as having squamous cell carcinomas; the cases were mostly diffusely positive for p40 and negative for TTF-1 (8G7G3/1). Twenty cases (4.2%) were reclassified as adenocarcinoma since they were positive for TTF-1 (8G7G3/1 or SPT24) with either no or focal p40 expression, and all of them were poorly-differentiated with squamoid morphology. In addition, 1 case was reclassified as adenosquamous carcinoma, 4 cases as large cell carcinoma, 4 cases as large cell neuroendocrine carcinoma, and 2 cases as small cell carcinoma. In poorly-differentiated non-small cell lung carcinomas, an accurate distinction between squamous cell carcinoma and adenocarcinoma cannot be reliably determined by morphology alone and requires immunohistochemical analysis, even in resected specimens. Our findings suggest that TTF-1 8G7G3/1 may be better suited as the primary antibody in differentiating adenocarcinoma from squamous cell carcinoma. PMID:25871623

  3. Expression and Bioinformatic Analysis of Ornithine Aminotransferase 
in Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Danfei ZHOU

    2012-09-01

    Full Text Available Background and objective It has been proven that ornithine aminotransferase (OAT might play an important role in the oncogenesis and progression of numerous malignant tumors. The aim of this study is to detect the mRNA and protein expression of OAT in non-small cell lung cancer (NSCLC, as well as to analyze the bioinformatic features and binary interactions. Methods OAT mRNA expression was detected in A549 and 16HBE cell lines by reverse transcription-polymerase chain reaction. OAT protein expression was determined in 55 cases of NSCLC and 17 cases of adjacent non-tumor lung tissues by immunohistochemical staining. The bioinformatic features and binary interactions of OAT were analyzed. Gene ontology annotation and signal pathway analysis were performed. Results OAT mRNA expression in A549 cells was 2.85-fold lower than that in 16HBE cells. OAT protein expression was significantly higher in NSCLC tissues than that in adjacent non-tumor lung tissues. A significant difference of OAT protein expression was existed between squamous cell lung cancer and adenocarcinoma (P<0.05, but was not correlated with the gender, age, lymph node metastasis, tumor size, and TNM stages. Bioinformatic analysis suggested that OAT was a highly homologous and stable protein located in the mitochondria. An aminotran-3 domain and several sites of phosphorylation, which may function in signal transduction, gene transcription, and molecular transit, were found. In the 54 selected binary interactions of OAT, TNF and TRAF6 play roles in the NF-κB pathway. Conclusion OAT may play an important role in the oncogenesis and progression of NSCLC. Thus, OAT may be a novel biomarker for the diagnosis of NSCLC or a new target for its treatment.

  4. SU-E-T-96: An Analysis of VMAT SBRT Lung Treatment Plans

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D; James, J; Wang, B; Dunlap, N; Woo, S; Silverman, C; Dragun, A; El-Ghamry, M [Univ Louisville, Louisville, KY (United States)

    2015-06-15

    Purpose: To present an analysis of 218 lung sbrt treatment plans delivered using Varian Eclipse RapidArc software and delivered with Varian linear accelerators. Methods: A retrospective analysis of treatment plans generated using the Varian Eclipse PRO RapidArc VMAT optimization and AAA photon beam calculation algorithms was done for 218 plans delivered using Varian Trilogy and TrueBeam linear accelerators. Some of the patients were enrolled in the RTOG 0813 and RTOG 0915 lung protocols. All of the patients’ plans were optimized using the guidelines outlined by these protocols. The plans presented were normalized so that 95% of the PTV volume received 100% of the prescribed dose. Results: The dose co formality constraints from the RTOG protocols and the number of plans within those constraints were:Tumor dose between 60% of maximum dose and 90% of maximum: 218/218 = 100%.Volume of 105% tumor dose outside put less than 15% of the PTV volume: 218/218 = 100%.Maximum dose 2 cm away from PTV within protocol table guidelines: No minor deviation: 188/218 = 86.2%. No major deviation: 216/218 = 99.1%.Ratio of 50% dose volume to PTV volume less than R50 in protocol table: No minor deviation 148/218 = 67.9%. No major deviation: 213/218 = 97.7%.Percent of lung receiving 20 Gy less than 10% (no minor violation): 218/218 = 100%.99% of PTV receiving at least 90% of the tumor dose: 214/218 = 98.2%. Conclusion: Varian RapidArc VMAT can successfully deliver lung SBRT treatments as outlined in the RTOG 0813 and 0915 protocols. The largest deviations were seen in the R50 constraints for the larger PTV volumes.

  5. Influence of Wall Surface and Air Modelling in Finite-Element Analysis of Sound Transmission Between Rooms in Lightweight Buildings

    DEFF Research Database (Denmark)

    Andersen, Lars Vabbersgaard; Kirkegaard, Poul Henning; Dickow, Kristoffer Ahrens

    2012-01-01

    Noise is a nuisance in the built environment, and to avoid undesirable transmission of sound and vibration within a building, its vibro-acoustic performance must be addressed in the design phase. For heavy structures, a reliable assessment of the sound pressure levels can be made by statistical...

  6. Musical Sound, Instruments, and Equipment

    Science.gov (United States)

    Photinos, Panos

    2017-12-01

    'Musical Sound, Instruments, and Equipment' offers a basic understanding of sound, musical instruments and music equipment, geared towards a general audience and non-science majors. The book begins with an introduction of the fundamental properties of sound waves, and the perception of the characteristics of sound. The relation between intensity and loudness, and the relation between frequency and pitch are discussed. The basics of propagation of sound waves, and the interaction of sound waves with objects and structures of various sizes are introduced. Standing waves, harmonics and resonance are explained in simple terms, using graphics that provide a visual understanding. The development is focused on musical instruments and acoustics. The construction of musical scales and the frequency relations are reviewed and applied in the description of musical instruments. The frequency spectrum of selected instruments is explored using freely available sound analysis software. Sound amplification and sound recording, including analog and digital approaches, are discussed in two separate chapters. The book concludes with a chapter on acoustics, the physical factors that affect the quality of the music experience, and practical ways to improve the acoustics at home or small recording studios. A brief technical section is provided at the end of each chapter, where the interested reader can find the relevant physics and sample calculations. These quantitative sections can be skipped without affecting the comprehension of the basic material. Questions are provided to test the reader's understanding of the material. Answers are given in the appendix.

  7. The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study.

    Science.gov (United States)

    Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel; Zoccali, Carmine

    2016-11-07

    Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound-guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre- and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at

  8. An IR Sounding-Based Analysis of the Saharan Air Layer in North Africa

    Science.gov (United States)

    Nicholls, Stephen D.; Mohr, Karen I.

    2018-01-01

    Intense daytime surface heating over barren-to-sparsely vegetated surfaces results in dry convective mixing. In the absence of external forcing such as mountain waves, the dry convection can produce a deep, well-mixed, nearly isentropic boundary layer that becomes a well-mixed residual layer in the evening. These well-mixed layers (WML) retain their unique mid-tropospheric thermal and humidity structure for several days. To detect the SAL and characterize its properties, AIRS Level 2 Ver. 6 temperature and humidity products (2003-Present) are evaluated against rawinsondes and compared to model analysis at each of the 55 rawinsonde stations in northern Africa. To distinguish WML from Saharan air layers (WMLs of Saharan origin), the detection involved a two-step process: 1) algorithm-based detection of WMLs in dry environments (less than 7 g per kilogram mixing ratio) 2) identification of Sahara air layers (SAL) by applying Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) back trajectories to determine the history of each WML. WML occurrence rates from AIRS closely resemble that from rawinsondes, yet rates from model analysis were up to 30% higher than observations in the Sahara due to model errors. Despite the overly frequent occurrence of WMLs from model analysis, HYSPLIT trajectory analysis showed that SAL occurrence rates (given a WML exists) from rawinsondes, AIRS, and model analysis were nearly identical. Although the number of WMLs varied among the data sources, the proportion of WMLs which were classified as SAL was nearly the same. The analysis of SAL bulk properties showed that AIRS and model analysis exhibited a slight warm and moist bias relative to rawinsondes in non-Saharan locations, but model analysis was notably warmer than rawinsondes and AIRS within the Sahara. The latter result is likely associated with the dearth of available data assimilated by model analysis in the Sahara. The variability of SAL thicknesses was reasonably

  9. Accuracy of lung nodule density on HRCT: analysis by PSF-based image simulation.

    Science.gov (United States)

    Ohno, Ken; Ohkubo, Masaki; Marasinghe, Janaka C; Murao, Kohei; Matsumoto, Toru; Wada, Shinichi

    2012-11-08

    A computed tomography (CT) image simulation technique based on the point spread function (PSF) was applied to analyze the accuracy of CT-based clinical evaluations of lung nodule density. The PSF of the CT system was measured and used to perform the lung nodule image simulation. Then, the simulated image was resampled at intervals equal to the pixel size and the slice interval found in clinical high-resolution CT (HRCT) images. On those images, the nodule density was measured by placing a region of interest (ROI) commonly used for routine clinical practice, and comparing the measured value with the true value (a known density of object function used in the image simulation). It was quantitatively determined that the measured nodule density depended on the nodule diameter and the image reconstruction parameters (kernel and slice thickness). In addition, the measured density fluctuated, depending on the offset between the nodule center and the image voxel center. This fluctuation was reduced by decreasing the slice interval (i.e., with the use of overlapping reconstruction), leading to a stable density evaluation. Our proposed method of PSF-based image simulation accompanied with resampling enables a quantitative analysis of the accuracy of CT-based evaluations of lung nodule density. These results could potentially reveal clinical misreadings in diagnosis, and lead to more accurate and precise density evaluations. They would also be of value for determining the optimum scan and reconstruction parameters, such as image reconstruction kernels and slice thicknesses/intervals.

  10. Lung cancer mortality among European rock/slag wool workers: exposure-response analysis.

    Science.gov (United States)

    Consonni, D; Boffetta, P; Andersen, A; Chang-Claude, J; Cherrie, J W; Ferro, G; Frentzel-Beyme, R; Hansen, J; Olsen, J; Plato, N; Westerholm, P; Saracci, R

    1998-08-01

    The purpose was to analyze the relationship between semi-quantitative indices of exposure to manmade vitreous fibers and lung cancer mortality among European rock/slag wool (RSW) workers. The study population comprised 9,603 male workers employed in RSW production in seven factories in Denmark, Norway, Sweden, and Germany, followed up for mortality as of 1990-91. Estimates of past exposure to respirable fibers were used to calculate cumulative exposure with a 15-year lag and maximum annual exposure based on employment history up to 1977. Rate ratios were estimated via multivariate Poisson regression, adjusting for country, age, calendar year, time since first employment, and employment status. A total of 159 lung cancer deaths were included in the analysis of which 97 among workers with more than one year of employment. We found nonstatistically significant trends in lung cancer risk according to cumulative exposure. Relative risks (RR) in the four quartiles were 1.0 (reference), 1.3 (95 percent confidence interval [CI] = 0.8-2.4), 1.2 (CI = 0.7-2.1), and 1.5 (CI = 0.7-3.0, P test for trend = 0.4). When workers with less than one year of employment were excluded, there was no increased risk; the RRs in the four quartiles were 1.0, 0.9 (CI = 0.4-2.0), 0.8 (CI = 0.3-1.9), and 1.0 (CI = 0.4-2.7). No trend was present according to maximum annual exposure. The results were not consistent among countries. We found a positive association between exposure to respirable fibers and lung cancer mortality. However, the lack of statistical significance, the dependence of the results on inclusion of short-term workers, the lack of consistency among countries, and the possible correlation between exposure to respirable fibers and to other agents reduce the weight of such evidence.

  11. Therapeutic effect analysis of three dimensional conformal radiotherapy non-small cell lung cancer

    International Nuclear Information System (INIS)

    Yao Zhijun; Cao Yongzhen; Zhang Wenxue; Liang Feng

    2012-01-01

    Objective: To analyse the treatment effect of non-small cell lung cancer of three dimensional conformal radiotherapy (3D-CRT) and to study the effect of patient survival related factors. Methods: Retrospective analysis was mack for 136 cases of non-small cell lung cancer, all accept 3D-CRT, through the case data collection and long-term follow-up, using the single factor and multiple factor analysis survival time and its influencing factors. Results: The recent curative effects of 136 cases of patients with three dimensional conformal radiotherapy: Complete response (CR) 14.7% (20/136), partial response (PR) 60.3 (82/136), stable disease(SD) 19.9% (27/136), progression disease (PD) 5.1% (7/136), total effective rate is 75% (102/136). One, two, three, five year survival rate is 79.4%, 45.4%, 22.1%, 12.5%. Side effects: Class 1 radiated esophagitis 35 cases, Class 2 radiated esophagitis 16 cases, Class 3 and above radiated esophagitis 0 case. Class I radiated pneumonia 20 cases, Class 2 radiated pneumonia 9 cases, Class 3 radiated pneumonia 0 case. Single factor analysis shows the influence of gender, age, pathology, phase, dose, and first-phase curative effect to the survival time are of a statistical significance, Multiple factor analysis showed KPS score, phase, dose, first-phase curative effect are the survival time independent factors. Conclusion: 3D-CRT for patients with non-small cell lung carcinoma is a safe, effective treatment method, Side effects are relatively low, and the patients survival time is long after radiotherapy. (authors)

  12. Analysis of significantly mutated genes as a clinical tool for the diagnosis in a case of lung cancer.

    Science.gov (United States)

    Miyashita, Yoshihiro; Hirotsu, Yosuke; Tsutsui, Toshiharu; Higashi, Seishi; Sogami, Yusuke; Kakizaki, Yumiko; Goto, Taichiro; Amemiya, Kenji; Oyama, Toshio; Omata, Masao

    2017-01-01

    Bronchoendoscopic examination is not necessarily comfortable procedure and limited by its sensitivity, depending on the location and size of the tumor lesion. Patients with a non-diagnostic bronchoendoscopic examination often undergo further invasive examinations. Non-invasive diagnostic tool of lung cancer is desired. A 72-year-old man had a 3.0 cm × 2.5 cm mass lesion in the segment B1 of right lung. Cytological examination of sputum, bronchial washing and curetted samples were all "negative". We could confirm a diagnosis of lung cancer after right upper lung lobe resection pathologically, and also obtained concordant results by genomic analysis using cytological negative samples from airways collected before operation. Genetic analysis showed mutational profiles of both resected specimens and samples from airways were identical. These data clearly indicated the next generation sequencing (NGS) may yield a diagnostic tool to conduct "precision medicine".

  13. Estimation of lung tumor position from multiple anatomical features on 4D-CT using multiple regression analysis.

    Science.gov (United States)

    Ono, Tomohiro; Nakamura, Mitsuhiro; Hirose, Yoshinori; Kitsuda, Kenji; Ono, Yuka; Ishigaki, Takashi; Hiraoka, Masahiro

    2017-09-01

    To estimate the lung tumor position from multiple anatomical features on four-dimensional computed tomography (4D-CT) data sets using single regression analysis (SRA) and multiple regression analysis (MRA) approach and evaluate an impact of the approach on internal target volume (ITV) for stereotactic body radiotherapy (SBRT) of the lung. Eleven consecutive lung cancer patients (12 cases) underwent 4D-CT scanning. The three-dimensional (3D) lung tumor motion exceeded 5 mm. The 3D tumor position and anatomical features, including lung volume, diaphragm, abdominal wall, and chest wall positions, were measured on 4D-CT images. The tumor position was estimated by SRA using each anatomical feature and MRA using all anatomical features. The difference between the actual and estimated tumor positions was defined as the root-mean-square error (RMSE). A standard partial regression coefficient for the MRA was evaluated. The 3D lung tumor position showed a high correlation with the lung volume (R = 0.92 ± 0.10). Additionally, ITVs derived from SRA and MRA approaches were compared with ITV derived from contouring gross tumor volumes on all 10 phases of the 4D-CT (conventional ITV). The RMSE of the SRA was within 3.7 mm in all directions. Also, the RMSE of the MRA was within 1.6 mm in all directions. The standard partial regression coefficient for the lung volume was the largest and had the most influence on the estimated tumor position. Compared with conventional ITV, average percentage decrease of ITV were 31.9% and 38.3% using SRA and MRA approaches, respectively. The estimation accuracy of lung tumor position was improved by the MRA approach, which provided smaller ITV than conventional ITV. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  14. Fruits, vegetables and lung cancer risk: a systematic review and meta-analysis.

    Science.gov (United States)

    Vieira, A R; Abar, L; Vingeliene, S; Chan, D S M; Aune, D; Navarro-Rosenblatt, D; Stevens, C; Greenwood, D; Norat, T

    2016-01-01

    Lung cancer is the most common cause of cancer death. Fruits and vegetables containing carotenoids and other antioxidants have been hypothesized to decrease lung cancer risk. As part of the World Cancer Research Fund International Continuous Update Project, we conducted a systematic review and meta-analysis of prospective studies. We searched PubMed and several databases up to December 2014 for prospective studies. We conducted meta-analyses comparing the highest and lowest intakes and dose-response meta-analyses to estimate summary relative risks (RRs) and 95% confidence intervals (CIs), and examine possible non-linear associations. We combined results from the Pooling Project with the studies we identified to increase the statistical power of our analysis. When comparing the highest with the lowest intakes, the summary RR estimates were 0.86 [95% CI 0.78-0.94; n (studies) = 18] for fruits and vegetables, 0.92 (95% CI 0.87-0.97; n = 25) for vegetables and 0.82 (95% CI 0.76-0.89; n = 29) for fruits. The association with fruit and vegetable intake was marginally significant in current smokers and inverse but not significant in former or never smokers. Significant inverse dose-response associations were observed for each 100 g/day increase: for fruits and vegetables [RR: 0.96; 95% CI 0.94-0.98, I(2) = 64%, n = 14, N (cases) = 9609], vegetables (RR: 0.94; 95% CI 0.89-0.98, I(2) = 48%, n = 20, N = 12 563) and fruits (RR: 0.92; 95% CI 0.89-0.95, I(2) = 57%, n = 23, N = 14 506). Our results were consistent among the different types of fruits and vegetables. The strength of the association differed across locations. There was evidence of a non-linear relationship (P fruit and vegetable intake and lung cancer risk showing that no further benefit is obtained when increasing consumption above ∼400 g per day. Eliminating tobacco smoking is the best strategy to prevent lung cancer. Although residual confounding by smoking cannot be ruled out, the current evidence from

  15. [Lung auscultation--an overview].

    Science.gov (United States)

    Bürgi, Urs; Huber, Lars Christian

    2015-07-01

    The auscultation of the lungs is - among anamnesis - the most important part in the assessment of patients presenting with pulmonary symptoms. The lung auscultation is reproducible, cost efficient and very helpful to distinguish between differential diagnoses, in particular in emergency situations. Detection and description of lung sounds requires experience and should be performed by strict adherence to the internationally accepted terminology. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Sound radiation modes of cylindrical surfaces and their application to vibro-acoustics analysis of cylindrical shells

    Science.gov (United States)

    Sun, Yao; Yang, Tiejun; Chen, Yuehua

    2018-06-01

    In this paper, sound radiation modes of baffled cylinders have been derived by constructing the radiation resistance matrix analytically. By examining the characteristics of sound radiation modes, it is found that radiation coefficient of each radiation mode increases gradually with the increase of frequency while modal shapes of sound radiation modes of cylindrical shells show a weak dependence upon frequency. Based on understandings on sound radiation modes, vibro-acoustics behaviors of cylindrical shells have been analyzed. The vibration responses of cylindrical shells are described by modified Fourier series expansions and solved by Rayleigh-Ritz method involving Flügge shell theory. Then radiation efficiency of a resonance has been determined by examining whether the vibration pattern is in correspondence with a sound radiation mode possessing great radiation efficiency. Furthermore, effects of thickness and boundary conditions on sound radiation of cylindrical shells have been investigated. It is found that radiation efficiency of thicker shells is greater than thinner shells while shells with a clamped boundary constraint radiate sound more efficiently than simply supported shells under thin shell assumption.

  17. In-Home Coal and Wood Use and Lung Cancer Risk: A Pooled Analysis of the International Lung Cancer Consortium

    OpenAIRE

    Hosgood, H. Dean; Boffetta, Paolo; Greenland, Sander; Lee, Yuan-Chin Amy; McLaughlin, John; Seow, Adeline; Duell, Eric J.; Andrew, Angeline S.; Zaridze, David; Szeszenia-Dabrowska, Neonila; Rudnai, Peter; Lissowska, Jolanta; Fabiánová, Eleonóra; Mates, Dana; Bencko, Vladimir

    2010-01-01

    Background Domestic fuel combustion from cooking and heating is an important public health issue because roughly 3 billion people are exposed worldwide. Recently, the International Agency for Research on Cancer classified indoor emissions from household coal combustion as a human carcinogen (group 1) and from biomass fuel (primarily wood) as a probable human carcinogen (group 2A). Objectives We pooled seven studies from the International Lung Cancer Consortium (5,105 cases and 6,535 controls)...

  18. Diaphragm and Lung Ultrasound to Predict Weaning Outcome: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Llamas-Álvarez, Ana M; Tenza-Lozano, Eva M; Latour-Pérez, Jaime

    2017-12-01

    Deciding the optimal timing for extubation in patients who are mechanically ventilated can be challenging, and traditional weaning predictor tools are not very accurate. The aim of this systematic review and meta-analysis was to assess the accuracy of lung and diaphragm ultrasound for predicting weaning outcomes in critically ill adults. MEDLINE, the Cochrane Library, Web of Science, Scopus, LILACS, Teseo, Tesis Doctorales en Red, and OpenGrey were searched, and the bibliographies of relevant studies were reviewed. Two researchers independently selected studies that met the inclusion criteria and assessed study quality in accordance with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The summary receiver-operating characteristic curve and pooled diagnostic OR (DOR) were estimated by using a bivariate random effects analysis. Sources of heterogeneity were explored by using predefined subgroup analyses and bivariate meta-regression. Nineteen studies involving 1,071 people were included in the study. For diaphragm thickening fraction, the area under the summary receiver-operating characteristic curve was 0.87, and DOR was 21 (95% CI, 11-40). Regarding diaphragmatic excursion, pooled sensitivity was 75% (95% CI, 65-85); pooled specificity, 75% (95% CI, 60-85); and DOR, 10 (95% CI, 4-24). For lung ultrasound, the area under the summary receiver-operating characteristic curve was 0.77, and DOR was 38 (95% CI, 7-198). Based on bivariate meta-regression analysis, a significantly higher specificity for diaphragm thickening fraction and higher sensitivity for diaphragmatic excursion was detected in studies with applicability concerns. Lung and diaphragm ultrasound can help predict weaning outcome, but its accuracy may vary depending on the patient subpopulation. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  19. Risk analysis of fatal and incidental lung tumors in wister rats after inhalation of plutonium dioxide

    International Nuclear Information System (INIS)

    Kai, M.; Akahane, K.; Ogiso, Y.

    2000-01-01

    Cancer risk analysis was done in animal studies for inhalation of plutonium dioxide. Female Wister rats were exposed to an aerosol of plutonium with AMAD of 0.4-0.5 μm and followed up until they died. We made some model analyses using their likelihood function. This approach enables us to consider temporal variation in dose-response analysis. Each rat contributes to the total likelihood depending on fatal or incidental tumors. In Weibul model analysis, the logarithm of the hazard function can be linearly modeled with the term of log (dose), log-L model, and additional term of the square of log (dose), log-LQ model. The likelihood ratio statistics gave a significantly better fit of the log-LQ model. However, if data more than 4 Gy were excluded, there was no significant difference between both models. The ratio of hazard function at 1 Gy and 0 Gy, the excess relative risk, showed 30 for total tumors. This result was much different from those in PNL data (Sanders et al.). The difference of pulmonary deposition depending upon particle size would cause different tumor incidence. Our studies indicated significant increase of occurrence of fatal lung cancer at an average dose of 0.5 Gy and thus did not suggest that a life-span effective threshold for death was about 1 Gy to the lung, which is shown in some papers. In contrast PNL, the incidence of adenoma showing the maximum at 0.5 Gy decreased with increasing lung dose from 1.5 Gy or higher, where malignant tumors such as adenocarcinomas increased. This phenomenon was analyzed with carcinogenesis models. (author)

  20. An automated classification system for the differentiation of obstructive lung diseases based on the textural analysis of HRCT images

    International Nuclear Information System (INIS)

    Park, Seong Hoon; Seo, Joon Beom; Kim, Nam Kug; Lee, Young Kyung; Kim, Song Soo; Chae, Eun Jin; Lee, June Goo

    2007-01-01

    To develop an automated classification system for the differentiation of obstructive lung diseases based on the textural analysis of HRCT images, and to evaluate the accuracy and usefulness of the system. For textural analysis, histogram features, gradient features, run length encoding, and a co-occurrence matrix were employed. A Bayesian classifier was used for automated classification. The images (image number n = 256) were selected from the HRCT images obtained from 17 healthy subjects (n = 67), 26 patients with bronchiolitis obliterans (n = 70), 28 patients with mild centrilobular emphysema (n = 65), and 21 patients with panlobular emphysema or severe centrilobular emphysema (n = 63). An five-fold cross-validation method was used to assess the performance of the system. Class-specific sensitivities were analyzed and the overall accuracy of the system was assessed with kappa statistics. The sensitivity of the system for each class was as follows: normal lung 84.9%, bronchiolitis obliterans 83.8%, mild centrilobular emphysema 77.0%, and panlobular emphysema or severe centrilobular emphysema 95.8%. The overall performance for differentiating each disease and the normal lung was satisfactory with a kappa value of 0.779. An automated classification system for the differentiation between obstructive lung diseases based on the textural analysis of HRCT images was developed. The proposed system discriminates well between the various obstructive lung diseases and the normal lung

  1. Proteomic analysis of bronchoalveolar lavage fluid (BALF) from lung cancer patients using label-free mass spectrometry.

    Science.gov (United States)

    Hmmier, Abduladim; O'Brien, Michael Emmet; Lynch, Vincent; Clynes, Martin; Morgan, Ross; Dowling, Paul

    2017-06-01

    Lung cancer is the leading cause of cancer-related mortality in both men and women throughout the world. The need to detect lung cancer at an early, potentially curable stage, is essential and may reduce mortality by 20%. The aim of this study was to identify distinct proteomic profiles in bronchoalveolar fluid (BALF) and plasma that are able to discriminate individuals with benign disease from those with non-small cell lung cancer (NSCLC). Using label-free mass spectrometry analysis of BALF during discovery-phase analysis, a significant number of proteins were found to have different abundance levels when comparing control to adenocarcinoma (AD) or squamous cell lung carcinoma (SqCC). Validation of candidate biomarkers identified in BALF was performed in a larger cohort of plasma samples by detection with enzyme-linked immunoassay. Four proteins (Cystatin-C, TIMP-1, Lipocalin-2 and HSP70/HSPA1A) were selected as a representative group from discovery phase mass spectrometry BALF analysis. Plasma levels of TIMP-1, Lipocalin-2 and Cystatin-C were found to be significantly elevated in AD and SqCC compared to control. The results presented in this study indicate that BALF is an important proximal biofluid for the discovery and identification of candidate lung cancer biomarkers. There is good correlation between the trend of protein abundance levels in BALF and that of plasma which validates this approach to develop a blood biomarker to aid lung cancer diagnosis, particularly in the era of lung cancer screening. The protein signatures identified also provide insight into the molecular mechanisms associated with lung malignancy.

  2. [Lung abscess and thoracic empyema: retrospective analysis in an internal medicine department].

    Science.gov (United States)

    Monteiro, Rita; Alfaro, Tiago M; Correia, Lurdes; Simão, Adélia; Carvalho, Armando; Costa, J Nascimento

    2011-12-01

    Lung abscess is a collection of necrotic and suppurated tissue located at the pulmonary parenchyma. Empyema is defined as the presence of pus in the pleural space. To study the clinical and microbiological characteristics, treatment and prognosis of patients with lung abscess and/or empyema admitted to an Internal Medicine ward. A retrospective analysis of medical records was performed, including all patients admitted to an Internal Medicine ward for lung abscess or empyema, between 2000 and 2008. Thirty patients were included (22 males/ eight females), accounting for 0.18% of all patients admitted in this ward in the same period. Three patients had pulmonary abscess, 18 empyema, and nine both diseases. The average age was 68.5 years (31 to 90). The most frequent complaints were dyspnoea (90%), fever (73.3%), cough (66.7%), weight loss (60%) and chest pain (53.3%). The most frequent associated disorders were stroke associated disability (46.7%), heart failure (43.3%) and arterial hypertension (33.3%). Thoracentesis was performed in all patients with empyema. In one patient with lung abscess an anaerobic microorganism was identified. In patients with empyema, cultures were positive in 61.1% of cases, with a slight predominance of methicillin-resistant Staphylococcus aureus (27.3%) and Prevotella intermedia (18.2%). In patients with both abscess and empyema, cultures of the abscess were positive in 44.4% and of the pleural fluid in 33.3%, with no predominant microorganism. Empiric antimicrobial therapy was started in all patients and later adapted to the antibiotic sensitivity test results. Surgery was performed in three patients. Seven patients (23.3%) died during admission. The average age of the patients who died was 81.3 years and of those who survived was 64.5 years. Lung abscess and empyema are infrequent diseases in an Internal Medicine ward, affect mostly males and have unspecific clinical manifestations. The chest X-ray, computed tomography (CT) and

  3. Statistical analysis of target motion in gated lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Zhao Bo; Yang Yong; Li Tianfang; Li Xiang; Heron, Dwight E; Huq, M Saiful

    2011-01-01

    An external surrogate-based respiratory gating technique is a useful method to reduce target margins for the treatment of a moving lung tumor. The success of this technique relies on a good correlation between the motion of the external markers and the internal tumor as well as the repeatability of the respiratory motion. In gated lung stereotactic body radiation therapy (SBRT), the treatment time for each fraction could exceed 30 min due to large fractional dose. Tumor motion may experience pattern changes such as baseline shift during such extended treatment time. The purpose of this study is to analyze tumor motion traces in actual treatment situations and to evaluate the effect of the target baseline shift in gated lung SBRT treatment. Real-time motion data for both the external markers and tumors from 51 lung SBRT treatments with Cyberknife Synchrony technology were analyzed in this study. The treatment time is typically greater than 30 min. The baseline shift was calculated with a rolling average window equivalent to ∼20 s and subtracted from that at the beginning. The magnitude of the baseline shift and its relationship with treatment time were investigated. Phase gating simulation was retrospectively performed on 12 carefully selected treatments with respiratory amplitude larger than 5 mm and regular phases. A customized gating window was defined for each individual treatment. It was found that the baseline shifts are specific to each patient and each fraction. Statistical analysis revealed that more than 69% treatments exhibited increased baseline shifts with the lapse of treatment time. The magnitude of the baseline shift could reach 5.3 mm during a 30 min treatment. Gating simulation showed that tumor excursion was caused mainly by the uncertainties in phase gating simulation and baseline shift, the latter being the primary factor. With a 5 mm gating window, 2 out of 12 treatments in the study group showed significant tumor excursion. Baseline shifts

  4. Analysis of the static pressure volume curve of the lung in experimentally induced pulmonary damage by CT-densitometry

    International Nuclear Information System (INIS)

    David, M.; Karmrodt, J.; Herwelling, A.; Bletz, C.; David, S.; Heussel, C.P.; Markstaller, K.

    2005-01-01

    Purpose: To study quantitative changes of lung density distributions when recording in- and expiratory static pressure-volume curves by single slice computed tomography (CT). Materials and Methods: Static in- and expiratory pressure volume curves (0 to 1000 ml, increments of 100 ml) were obtained in random order in 10 pigs after induction of lung damage by saline lavage. Simultaneously, CT acquisitions (slice thickness 1 mm, temporal increment 2 s) were performed in a single slice (3 cm below the carina). In each CT image lung segmentation and planimetry of defined density ranges were achieved. The lung density ranges were defined as: hyperinflated (-1024 to -910 HU), normal aerated (-910 to -600 HU), poorly aerated (-600 to -300 HU), and non aerated (-300 to 200 HU) lung. Fractional areas of defined density ranges in percentage of total lung area were compared to recorded volume increments and airway pressures (atmospheric pressure, lower inflection point (LIP), LIP*0.5, LIP*1.5, peak airway pressure) of in- and expiratory pressure-volume curves. Results: Quantitative analysis of defined density ranges showed no differences between in- and expiratory pressure-volume curves. The amount of poorly aerated lung decreased and normal aerated lung increased constantly when airway pressure and volume were increased during inspiratory pressure-volume curves and vice versa during expiratory pressure-volume loops. Conclusion: Recruitment and derecruitment of lung atelectasis during registration of static in- and expiratory pressure-volume loops occurred constantly, but not in a stepwise manner. CT was shown to be an appropriate method to analyse these recruitment process. (orig.)

  5. Hypersensitivity to sound in tinnitus patients: an analysis of a construct based on questionnaire and audiological data.

    Science.gov (United States)

    Bläsing, Lena; Goebel, Gerhard; Flötzinger, Uta; Berthold, Anke; Kröner-Herwig, Birgit

    2010-07-01

    The purpose of this study was to analyse the Questionnaire on Hypersensitivity to Sound (GUF; Nelting & Finlayson, 2004 ) and to improve its validity based on the analysis of intercorrelations (single item level) with other methods of assessing hyperacusis (uncomfortable loudness level, individual loudness function, self-rated severity of hyperacusis). Subjects consisted of 91 inpatients with tinnitus and hyperacusis. The GUF showed a good reliability (alpha = .92). The factorial structure of the questionnaire reported by Nelting et al (2002) was not completely supported by the evidence in this study. The total score and the single items showed small to moderate correlations with the other modes of measuring hyperacusis. Evidence for convergent and discriminant validity were found, but overall the results corroborate the conceptual heterogeneity of the construct hyperacusis and its dependency on the assessment method. Four items of the GUF with particularly low correlations were excluded from the questionnaire. The revised GUF total score showed slightly but not statistically significant higher convergent and discriminant validity.

  6. Aeronomy report no. 73: analysis of sounding rocket data from Punta Chilca, Peru

    International Nuclear Information System (INIS)

    Fillinger, R.W. Jr; Mechtly, E.A.; Walton, E.K.

    1976-01-01

    A technique is described for measuring electron concentrations in the lower portion of the ionosphere above Punta Chilca. A radio-propagation experiment for measuring Faraday rotation is combined with a dc/Langmuir probe experiment for measuring electron current. The results obtained from the analysis of radio and probe data from Nike Apache 14.532, which was launched at 20:26 UT on May 28, 1975, at a solar zenith angle of 60 deg are presented. A comparison of the profiles of electron concentration indicates that the value of the maximum ionization in the D region under quiet conditions is proportional to the square of the cosine of the solar zenith angle

  7. Finite-element analysis of elastic sound-proof coupling thermal state

    Science.gov (United States)

    Tsyss, V. G.; Strokov, I. M.; Sergaeva, M. Yu

    2018-01-01

    The aim is in calculated determining of the elastic rubber-metal element thermal state of soundproof coupling ship shafting under variable influence during loads in time. Thermal coupling calculation is performed with finite element method using NX Simens software with Nastran solver. As a result of studies, the following results were obtained: - a volumetric picture of the temperature distribution over the array of the deformed coupling body is obtained; - time to reach steady-state thermal coupling mode has been determined; - dependences of maximum temperature and time to reach state on the established operation mode on rotation frequency and ambient temperature are determined. The findings prove the conclusion that usage of finite element analysis modern software can significantly speed up problem solving.

  8. Statistically sound evaluation of trace element depth profiles by ion beam analysis

    International Nuclear Information System (INIS)

    Schmid, K.; Toussaint, U. von

    2012-01-01

    This paper presents the underlying physics and statistical models that are used in the newly developed program NRADC for fully automated deconvolution of trace level impurity depth profiles from ion beam data. The program applies Bayesian statistics to find the most probable depth profile given ion beam data measured at different energies and angles for a single sample. Limiting the analysis to % level amounts of material allows one to linearize the forward calculation of ion beam data which greatly improves the computation speed. This allows for the first time to apply the maximum likelihood approach to both the fitting of the experimental data and the determination of confidence intervals of the depth profiles for real world applications. The different steps during the automated deconvolution will be exemplified by applying the program to artificial and real experimental data.

  9. Sound Search Engine Concept

    DEFF Research Database (Denmark)

    2006-01-01

    Sound search is provided by the major search engines, however, indexing is text based, not sound based. We will establish a dedicated sound search services with based on sound feature indexing. The current demo shows the concept of the sound search engine. The first engine will be realased June...

  10. Semiquantitative Culture Analysis during Therapy for Mycobacterium avium Complex Lung Disease.

    Science.gov (United States)

    Griffith, David E; Adjemian, Jennifer; Brown-Elliott, Barbara A; Philley, Julie V; Prevots, D Rebecca; Gaston, Christopher; Olivier, Kenneth N; Wallace, Richard J

    2015-09-15

    Microbiologically based criteria such as sputum culture conversion to negative have traditionally been used to define treatment success for mycobacterial diseases. There are, however, limited data regarding whether nontuberculous mycobacterial sputum culture conversion or semiquantitative culture analysis correlates with subjective or nonmicrobiologic objective indices of treatment response. To determine whether a semiquantitative mycobacterial culture scale correlated with clinical disease status and was predictive of long-term sputum mycobacterial culture conversion to negative in a cohort of patients with nodular/bronchiectatic Mycobacterium avium complex lung disease undergoing therapy. One hundred and eighty patients undergoing standard macrolide-based therapy for M. avium complex lung disease were monitored at standard frequent intervals with symptomatic, radiographic, and microbiologic data collected, including semiquantitative mycobacterial culture analysis. Analyses were used to evaluate clinical and microbiologic predictors of long-term sputum conversion to culture negative. After 12 months of therapy, 148 (82%) patients had sputum conversion to culture negative. Baseline semiquantitative sputum culture scores did not differ between patients with sputum conversion and those without. The change in sputum culture semiquantitative score from baseline to Month 3 was highly predictive of subsequent sputum long-term conversion status indicative of treatment success, as was improvement in cough, and especially early radiographic improvement. Early semiquantitative sputum agar plate culture results can be used to predict symptomatic and radiographic improvement as well as long-term sputum culture conversion to negative in this population. We suggest that semiquantitative sputum culture scores can be a useful tool for evaluating new nontuberculous mycobacterial lung disease therapies.

  11. Simulation of lung cancer treatment with equivalent dose calculation and analysis of the dose distribution profile

    International Nuclear Information System (INIS)

    Thalhofer, J. L.; Marques L, J.; Da Silva, A. X.; Dos Reis J, J. P.; Da Silva J, W. F. R.; Arruda C, S. C.; Monteiro de S, E.; Santos B, D. V.

    2017-10-01

    Actually, lung cancer is one of the most lethal types, due to the disease in the majority of the cases asymptomatic in the early stages, being the detection of the pathology in advanced stage, with tumor considerable volume. Dosimetry analysis of healthy organs under real conditions is not feasible. Therefore, computational simulations are used to auxiliary in dose verification in organs of patients submitted to radiotherapy. The goal of this study is to calculate the equivalent dose, due to photons, in surrounding in healthy organs of a patient submitted to radiotherapy for lung cancer, through computational modeling. The simulation was performed using the MCNPX code (Version, 2006], Rex and Regina phantom [ICRP 110, 2008], radiotherapy room, Siemens Oncor Expression accelerator operating at 6 MV and treatment protocol adopted at the Inca (National Cancer Institute, Brazil). The results obtained, considering the dose due to photons for both phantom indicate that organs located inside the thoracic cavity received higher dose, being the bronchi, heart and esophagus more affected, due to the anatomical positioning. Clinical data describe the development of bronchiolitis, esophagitis, and cardiomyopathies with decreased cardiopulmonary function as one of the major effects of lung cancer treatment. In the Regina phantom, the second largest dose was in the region of the breasts with 615,73 mSv / Gy, while in the Rex 514,06 mSv / Gy, event related to the difference of anatomical structure of the organ. Through the t mesh command, a qualitative analysis was performed between the dose deposition profile of the planning system and the simulated treatment, with a similar profile of the dose distribution being verified along the patients body. (Author)

  12. Dose-volume histogram analysis as predictor of radiation pneumonitis in primary lung cancer patients treated with radiotherapy

    International Nuclear Information System (INIS)

    Fay, Michael; Tan, Alex; Fisher, Richard; Mac Manus, Michael; Wirth, Andrew; Ball, David

    2005-01-01

    Purpose: To determine the relationship between various parameters derived from lung dose-volume histogram analysis and the risk of symptomatic radiation pneumonitis (RP) in patients undergoing radical radiotherapy for primary lung cancer. Methods and Materials: The records of 156 patients with lung cancer who had been treated with radical radiotherapy (≥45 Gy) and for whom dose-volume histogram data were available were reviewed. The incidence of symptomatic RP was correlated with a variety of parameters derived from the dose-volume histogram data, including the volume of lung receiving 10 Gy (V 10 ) through 50 Gy (V 50 ) and the mean lung dose (MLD). Results: The rate of RP at 6 months was 15% (95% confidence interval 9-22%). On univariate analysis, only V 30 (p = 0.036) and MLD (p = 0.043) were statistically significantly related to RP. V 30 correlated highly positively with MLD (r = 0.96, p 30 and MLD can be used to predict the risk of RP in lung cancer patients undergoing radical radiotherapy

  13. Association between cooking oil fume exposure and lung cancer among Chinese nonsmoking women: a meta-analysis.

    Science.gov (United States)

    Xue, Yingbo; Jiang, Ying; Jin, Shan; Li, Yong

    2016-01-01

    Lung cancer has been the main cause of cancer death around the world. Cigarette smoking has been identified as a risk factor for lung cancer in males. However, the etiological factors in nonsmoking women remain elusive. A meta-analysis was conducted to evaluate the relationship between cooking oil fume exposure and lung cancer among Chinese nonsmoking women. Thirteen articles containing three population-based case-control and ten hospital-based case-control studies were included in this meta-analysis. These studies with a total of 3,596 lung cancer women and 6,082 healthy controls were analyzed by RevMan 5.3. Fixed effects model or random effects model was used to obtain pooled estimates of risk ratio. The risk ratios with a 95% CI were 1.74 (95% CI =1.57-1.94) and 2.11 (95% CI =1.54-2.89), respectively. Cooking oil fume exposure as well as not using a kitchen ventilator when cooking was significantly associated with lung cancer among nonsmoking women (Z=10.07, Poil fume exposure, especially lacking a fume extractor, may increase the risk of lung cancer among Chinese nonsmoking women.

  14. Spatial and dose–response analysis of fibrotic lung changes after stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Vinogradskiy, Yevegeniy; Diot, Quentin; Kavanagh, Brian; Schefter, Tracey; Gaspar, Laurie; Miften, Moyed

    2013-01-01

    Purpose: Stereotactic body radiation therapy (SBRT) is becoming the standard of care for early stage nonoperable lung cancers. Accurate dose–response modeling is challenging for SBRT because of the decreased number of clinical toxicity events. As a surrogate for a clinical toxicity endpoint, studies have proposed to use radiographic changes in follow up computed tomography (CT) scans to evaluate lung SBRT normal tissue effects. The purpose of the current study was to use local fibrotic lung regions to spatially and dosimetrically evaluate lung changes in patients that underwent SBRT.Methods: Forty seven SBRT patients treated at our institution from 2003 to 2009 were used for the current study. Our patient cohort had a total of 148 follow up CT scans ranging from 3 to 48 months post-therapy. Post-treatment scans were binned into intervals of 3, 6, 12, 18, 24, 30, and 36 months after the completion of treatment. Deformable image registration was used to align the follow up CT scans with the pretreatment CT and dose distribution. Areas of visible fibrotic changes were contoured. The centroid of each gross tumor volume (GTV) and contoured fibrosis volume was calculated and the fibrosis volume location and movement (magnitude and direction) relative to the GTV and 30 Gy isodose centroid were analyzed. To perform a dose–response analysis, each voxel in the fibrosis volume was sorted into 10 Gy dose bins and the average CT number value for each dose bin was calculated. Dose–response curves were generated by plotting the CT number as a function of dose bin and time posttherapy.Results: Both fibrosis and GTV centroids were concentrated in the upper third of the lung. The average radial movement of fibrosis centroids relative to the GTV centroids was 2.6 cm with movement greater than 5 cm occurring in 11% of patients. Evaluating dose–response curves revealed an overall trend of increasing CT number as a function of dose. The authors observed a CT number plateau at

  15. Unexpandable lung.

    Science.gov (United States)

    Pereyra, Marco F; Ferreiro, Lucía; Valdés, Luis

    2013-02-01

    Unexpandable lung is a mechanical complication by which the lung does not expand to the chest wall, impeding a normal apposition between the two pleural layers. The main mechanism involved is the restriction of the visceral pleura due to the formation of a fibrous layer along this pleural membrane. This happens because of the presence of an active pleural disease (lung entrapment), which can be resolved if proper therapeutic measures are taken, or a remote disease (trapped lung), in which an irreversible fibrous pleural layer has been formed. The clinical suspicion arises with the presence of post-thoracocentesis hydropneumothorax or a pleural effusion that cannot be drained due to the appearance of thoracic pain. The diagnosis is based on the analysis of the pleural liquid, the determination of pleural pressures as we drain the effusion and on air-contrast chest CT. As both represent the continuity of one same process, the results will depend on the time at which these procedures are done. If, when given a lung that is becoming entrapped, the necessary therapeutic measures are not taken, the final result will be a trapped lung. In this instance, most patients are asymptomatic or have mild exertional dyspnea and therefore they do not require treatment. Nevertheless, in cases of incapacitating dyspnea, it may be necessary to use pleural decortication in order to resolve the symptoms. Copyright © 2012 SEPAR. Published by Elsevier Espana. All rights reserved.

  16. Identification of Importin 8 (IPO8 as the most accurate reference gene for the clinicopathological analysis of lung specimens

    Directory of Open Access Journals (Sweden)

    Pio Ruben

    2008-11-01

    Full Text Available Abstract Background The accurate normalization of differentially expressed genes in lung cancer is essential for the identification of novel therapeutic targets and biomarkers by real time RT-PCR and microarrays. Although classical "housekeeping" genes, such as GAPDH, HPRT1, and beta-actin have been widely used in the past, their accuracy as reference genes for lung tissues has not been proven. Results We have conducted a thorough analysis of a panel of 16 candidate reference genes for lung specimens and lung cell lines. Gene expression was measured by quantitative real time RT-PCR and expression stability was analyzed with the softwares GeNorm and NormFinder, mean of |ΔCt| (= |Ct Normal-Ct tumor| ± SEM, and correlation coefficients among genes. Systematic comparison between candidates led us to the identification of a subset of suitable reference genes for clinical samples: IPO8, ACTB, POLR2A, 18S, and PPIA. Further analysis showed that IPO8 had a very low mean of |ΔCt| (0.70 ± 0.09, with no statistically significant differences between normal and malignant samples and with excellent expression stability. Conclusion Our data show that IPO8 is the most accurate reference gene for clinical lung specimens. In addition, we demonstrate that the commonly used genes GAPDH and HPRT1 are inappropriate to normalize data derived from lung biopsies, although they are suitable as reference genes for lung cell lines. We thus propose IPO8 as a novel reference gene for lung cancer samples.

  17. Offering lung cancer screening to high-risk medicare beneficiaries saves lives and is cost-effective: an actuarial analysis.

    Science.gov (United States)

    Pyenson, Bruce S; Henschke, Claudia I; Yankelevitz, David F; Yip, Rowena; Dec, Ellynne

    2014-08-01

    By a wide margin, lung cancer is the most significant cause of cancer death in the United States and worldwide. The incidence of lung cancer increases with age, and Medicare beneficiaries are often at increased risk. Because of its demonstrated effectiveness in reducing mortality, lung cancer screening with low-dose computed tomography (LDCT) imaging will be covered without cost-sharing starting January 1, 2015, by nongrandfathered commercial plans. Medicare is considering coverage for lung cancer screening. To estimate the cost and cost-effectiveness (ie, cost per life-year saved) of LDCT lung cancer screening of the Medicare population at high risk for lung cancer. Medicare costs, enrollment, and demographics were used for this study; they were derived from the 2012 Centers for Medicare & Medicaid Services (CMS) beneficiary files and were forecast to 2014 based on CMS and US Census Bureau projections. Standard life and health actuarial techniques were used to calculate the cost and cost-effectiveness of lung cancer screening. The cost, incidence rates, mortality rates, and other parameters chosen by the authors were taken from actual Medicare data, and the modeled screenings are consistent with Medicare processes and procedures. Approximately 4.9 million high-risk Medicare beneficiaries would meet criteria for lung cancer screening in 2014. Without screening, Medicare patients newly diagnosed with lung cancer have an average life expectancy of approximately 3 years. Based on our analysis, the average annual cost of LDCT lung cancer screening in Medicare is estimated to be $241 per person screened. LDCT screening for lung cancer in Medicare beneficiaries aged 55 to 80 years with a history of ≥30 pack-years of smoking and who had smoked within 15 years is low cost, at approximately $1 per member per month. This assumes that 50% of these patients were screened. Such screening is also highly cost-effective, at <$19,000 per life-year saved. If all eligible Medicare

  18. Genetic and molecular analysis of radon-induced rat lung tumours

    International Nuclear Information System (INIS)

    Guilly, M.N.; Joubert, Ch.; Levalois, C.; Dano, L.; Chevillard, S.

    2002-01-01

    We have a model of radon-induced rat lung tumours, which allow us to analyse the cytogenetic and molecular alterations of the tumours. The aim is to better understand the mechanisms of radio-induced carcinogenesis and to define if it exists a specificity of radio-induced genetic alterations as compared to the genetic alterations found in the sporadic tumours. We have started our analysis by developing global cytogenetic and molecular approaches. We have shown that some alterations are recurrent. The genes that are potentially involved are the oncogene MET and the tumour suppressor Bene p16, which are also frequently altered in human lung tumours. Simultaneously, we have focussed our analysis by targeting the search of mutation in the tumour suppressor gene TP3. We have found that 8 of 39 tumours were mutated by deletion in the coding sequence of TP53. This high frequency of deletion, which is not observed in the human p53 mutation database could constitute a signature of radio-induced alterations. On this assumption, this type of alteration should not be only found on TP53 Bene but also in other suppressor genes which are inactivated by a mutation such as p16 for example. The work we are carrying out on radio-induced tumours among humans and animals is directed to this end. (author)

  19. A Statistical Analysis of Langmuir Wave-Electron Correlations Observed by the CHARM II Auroral Sounding Rocket

    Science.gov (United States)

    Dombrowski, M. P.; Labelle, J. W.; Kletzing, C.; Bounds, S. R.; Kaeppler, S. R.

    2014-12-01

    Langmuir-mode electron plasma waves are frequently observed by spacecraft in active plasma environments such as the ionosphere. Ionospheric Langmuir waves may be excited by the bump-on-tail instability generated by impinging beams of electrons traveling parallel to the background magnetic field (B). The Correlation of High-frequencies and Auroral Roar Measurement (CHARM II) sounding rocket was launched into a substorm at 9:49 UT on 17 February 2010, from the Poker Flat Research Range in Alaska. The primary instruments included the University of Iowa Wave-Particle Correlator (WPC), the Dartmouth High-Frequency Experiment (HFE), several charged particle detectors, low-frequency wave instruments, and a magnetometer. The HFE is a receiver system which effectively yields continuous (100% duty cycle) electric-field waveform measurements from 100 kHz to 5 MHz, and which had its detection axis aligned nominally parallel to B. The HFE output was fed on-payload to the WPC, which uses a phase-locked loop to track the incoming wave frequency with the most power, then sorting incoming electrons at eight energy levels into sixteen wave-phase bins. CHARM II encountered several regions of strong Langmuir wave activity throughout its 15-minute flight, and the WPC showed wave-lock and statistically significant particle correlation distributions during several time periods. We show results of an in-depth analysis of the CHARM II WPC data for the entire flight, including statistical analysis of correlations which show evidence of direct interaction with the Langmuir waves, indicating (at various times) trapping of particles and both driving and damping of Langmuir waves by particles. In particular, the sign of the gradient in particle flux appears to correlate with the phase relation between the electrons and the wave field, with possible implications for the wave physics.

  20. NASA Space Sounds API

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA has released a series of space sounds via sound cloud. We have abstracted away some of the hassle in accessing these sounds, so that developers can play with...

  1. Chronic exposure to chlorophenol related compounds in the pesticide production workplace and lung cancer: a meta-analysis.

    Science.gov (United States)

    Zendehdel, Rezvan; Tayefeh-Rahimian, Raana; Kabir, Ali

    2014-01-01

    Chlorophenols (CPs) and related phenoxyacetic acids (PAs) are pesticide groups contaminated with highly toxic 2, 3, 7, 8-tetrachlorodibenzo-p-dioxin (TCDD) during production. PAs and CPs exposure is associated with risk of cancer, but the situation regarding lung cancer has not been clearly defined. We proposed a meta-analysis of published researches to evaluate relationship between chronic exposure to PAs and CPs in pesticide production workplaces and the risk of lung cancer. After searching PubMed, Scopus, Scholar Google, Web of Sciences until August 2013, the association between chronic PAs and CPs exposure in production workplace and lung cancer was studied in 15 cohort studies. The standardized mortality rate (SMR) and 95% confidence intervals (CI) were collected from the papers. We used random or fixed-effects models, Egger test, funnel plot and meta regression in our analysis. Five papers with six reports were included in the final analysis. The standardized mortality rate for lung cancer from the random model was 1.18 (95% CI: 1.03-1.35, p=0.014) with moderate heterogeneity. Publication bias was not found for included studies in meta-analysis (p=0.9). Our findings has strengthen the evidence of lung cancer from chronic exposure to chlorophenol related compounds (PAs, CPs).

  2. Decision Tree of Occupational Lung Cancer Using Classification and Regression Analysis

    Directory of Open Access Journals (Sweden)

    Tae-Woo Kim

    2010-12-01

    Conclusion: We found that exposure to lung carcinogens, latency and smoking history were predictive factors of approval for occupational lung cancer. Further studies for work-relatedness of occupational disease are needed.

  3. Clonal heterogeneity of small-cell anaplastic carcinoma of the lung demonstrated by flow-cytometric DNA analysis

    DEFF Research Database (Denmark)

    Vindeløv, L L; Hansen, H H; Christensen, I J

    1980-01-01

    Flow-cytometric DNA analysis yields information on ploidy and proliferative characteristics of a cell population. The analysis was implemented on small-cell anaplastic carcinoma of the lung using a rapid detergent technique for the preparation of fine-needle aspirates for DNA determination and a ...

  4. Analysis of resveratrol and radiation effects in lung cancer cells by micronucleus assay

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, Carolina S.; Santos, Dymes R.A.; Vieira, Daniel P.; Rogero, Sizue O.; Rogero, Jose R., E-mail: carolina_sm@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Weltman, Eduardo [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil); Cruz, Aurea S.; Santos, Rezolina P. [Instituto Adolfo Lutz, Sao Paulo, SP (Brazil)

    2015-07-01

    Mucoepidermoid lung carcinoma is frequently manifested by obstructive trachea symptoms. Radiation and drugs combinations are commonly used in the lung cancer treatment. Currently there is a strong tendency to develop therapeutic strategies focused at the administration of high potential compounds to improve the ionizing radiation treatments, so as to increase the radiation effects on tumor cell while minimizing these effects to surrounding normal tissues. Resveratrol is a polyphenolic phytoalexin compound present in wines and several plants. This compound has a broad spectrum of biological activities such as antioxidant, anticarcinogenic, and induction of cell cycle arrest effects. Analysis of biological effects of ionizing radiation in the presence of resveratrol in different cell cultures has been the subject of many studies. To verify the genotoxic effects in cells exposed to ionizing radiation many methods have been proposed. The cytokinesis-block micronucleus technique is one of the preferred methods. The main of this study was to detect and quantify radioinduced DNA damage in mucoepidermoid lung carcinoma cells (NCI-H292) by cytokinesis-block micronucleus technique using cytocalasin-B. The cell culture was irradiated at a single fraction from a TrueBeam® linear accelerator (0, 0.8, 5, and 10 Gy), in the absence or presence of different resveratrol concentrations (0, 15, 30, and 60 μM). The results showed that resveratrol (15 and μM) induced significant increase frequency (p<0.05) of micronucleus formation in NCI-H292 cell culture non-irradiated and exposed at 5 Gy dose. Moreover, resveratrol (30 μM) induced micronucleus formation at 0.8 Gy dose. (author)

  5. Analysis of resveratrol and radiation effects in lung cancer cells by micronucleus assay

    International Nuclear Information System (INIS)

    Moreno, Carolina S.; Santos, Dymes R.A.; Vieira, Daniel P.; Rogero, Sizue O.; Rogero, Jose R.; Sakuraba, Roberto K.; Weltman, Eduardo; Cruz, Aurea S.; Santos, Rezolina P.

    2015-01-01

    Mucoepidermoid lung carcinoma is frequently manifested by obstructive trachea symptoms. Radiation and drugs combinations are commonly used in the lung cancer treatment. Currently there is a strong tendency to develop therapeutic strategies focused at the administration of high potential compounds to improve the ionizing radiation treatments, so as to increase the radiation effects on tumor cell while minimizing these effects to surrounding normal tissues. Resveratrol is a polyphenolic phytoalexin compound present in wines and several plants. This compound has a broad spectrum of biological activities such as antioxidant, anticarcinogenic, and induction of cell cycle arrest effects. Analysis of biological effects of ionizing radiation in the presence of resveratrol in different cell cultures has been the subject of many studies. To verify the genotoxic effects in cells exposed to ionizing radiation many methods have been proposed. The cytokinesis-block micronucleus technique is one of the preferred methods. The main of this study was to detect and quantify radioinduced DNA damage in mucoepidermoid lung carcinoma cells (NCI-H292) by cytokinesis-block micronucleus technique using cytocalasin-B. The cell culture was irradiated at a single fraction from a TrueBeam® linear accelerator (0, 0.8, 5, and 10 Gy), in the absence or presence of different resveratrol concentrations (0, 15, 30, and 60 μM). The results showed that resveratrol (15 and μM) induced significant increase frequency (p<0.05) of micronucleus formation in NCI-H292 cell culture non-irradiated and exposed at 5 Gy dose. Moreover, resveratrol (30 μM) induced micronucleus formation at 0.8 Gy dose. (author)

  6. Association between cooking oil fume exposure and lung cancer among Chinese nonsmoking women: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Xue Y

    2016-05-01

    Full Text Available Yingbo Xue, Ying Jiang, Shan Jin, Yong Li Department of Oncology, Guizhou Provincial People’s Hospital, Guiyang, Guizhou, People’s Republic of China Abstract: Lung cancer has been the main cause of cancer death around the world. Cigarette smoking has been identified as a risk factor for lung cancer in males. However, the etiological factors in nonsmoking women remain elusive. A meta-analysis was conducted to evaluate the relationship between cooking oil fume exposure and lung cancer among Chinese nonsmoking women. Thirteen articles containing three population-based case–control and ten hospital-based case–control studies were included in this meta-analysis. These studies with a total of 3,596 lung cancer women and 6,082 healthy controls were analyzed by RevMan 5.3. Fixed effects model or random effects model was used to obtain pooled estimates of risk ratio. The risk ratios with a 95% CI were 1.74 (95% CI =1.57–1.94 and 2.11 (95% CI =1.54–2.89, respectively. Cooking oil fume exposure as well as not using a kitchen ventilator when cooking was significantly associated with lung cancer among nonsmoking women (Z=10.07, P<0.00001; Z=4.65, P<0.00001. Cooking oil fume exposure, especially lacking a fume extractor, may increase the risk of lung cancer among Chinese nonsmoking women. Keywords: cooking oil fume exposure, lung cancer, meta-analysis, nonsmoking women 

  7. WE-FG-202-03: Quantitative CT-Based Analysis to Assess Lung Injury Following Proton Radiotherapy

    International Nuclear Information System (INIS)

    Underwood, T; Grassberger, C; Willers, H; MacDonald, S; Jimenez, R; Paganetti, H

    2016-01-01

    Purpose: Relative to photon alternatives, the increased dose-conformity associated with proton therapy is expected to reduce the extent of radiation-induced lung toxicity. However, analysis of follow-up data is yet to be published in this area. In this study we retrospectively analyzed late-phase HU changes for proton therapy cohorts of chest wall and lung patients. Methods: From our institution’s register of patients treated using double-scattered protons, all chest wall and stereotactic lung cases (treated 2011–2012 and 2008–2014 respectively) were initially considered. Follow-up CT data were accessible for 10 chest wall cases (prescribed 50.4 GyRBE in 28 fractions) and 16 lung cases (prescribed 42–50 GyRBE in 3–4 fractions). CT time-points ranged from 0.5–3.5 years post-treatment. Planning doses were recalculated using TOPAS Monte Carlo simulations and mapped onto the follow-up images using deformable registration. Excluding internal target volumes, changes in HU between each patient’s planning and follow-up CT(s) were evaluated for dose bins of 2–30 GyRBE (2 GyRBE increments). Results: Linear increases in HU per unit dose, with correlations statistically significant at the 1% level (one-sided Spearman’s rank test), were evident for all 10 chest wall cases and 14/16 lung cases. The mean changes in HU/Gy were: 1.76 (SD=0.73) for the chest wall cohort, and 1.40 (SD=0.87) for the lung cohort. The median scan times post treatment were 21 and 12 months respectively. All 26 patients developed solid consolidation (scar-like radiographic opacities) within the exposed lung(s). Conclusion: Analysis of follow-up CTs revealed statistically significant correlations in HU-change/dose for two proton cohorts (lung and chest wall). Quantitatively, the late-phase changes we report broadly match published photon data. Further analysis of such radiographic changes, particularly via matched cohort studies drawing upon consistent imaging protocols, could play an

  8. WE-FG-202-03: Quantitative CT-Based Analysis to Assess Lung Injury Following Proton Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Underwood, T [Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); University College London, London (United Kingdom); Grassberger, C; Willers, H; MacDonald, S; Jimenez, R; Paganetti, H [Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Relative to photon alternatives, the increased dose-conformity associated with proton therapy is expected to reduce the extent of radiation-induced lung toxicity. However, analysis of follow-up data is yet to be published in this area. In this study we retrospectively analyzed late-phase HU changes for proton therapy cohorts of chest wall and lung patients. Methods: From our institution’s register of patients treated using double-scattered protons, all chest wall and stereotactic lung cases (treated 2011–2012 and 2008–2014 respectively) were initially considered. Follow-up CT data were accessible for 10 chest wall cases (prescribed 50.4 GyRBE in 28 fractions) and 16 lung cases (prescribed 42–50 GyRBE in 3–4 fractions). CT time-points ranged from 0.5–3.5 years post-treatment. Planning doses were recalculated using TOPAS Monte Carlo simulations and mapped onto the follow-up images using deformable registration. Excluding internal target volumes, changes in HU between each patient’s planning and follow-up CT(s) were evaluated for dose bins of 2–30 GyRBE (2 GyRBE increments). Results: Linear increases in HU per unit dose, with correlations statistically significant at the 1% level (one-sided Spearman’s rank test), were evident for all 10 chest wall cases and 14/16 lung cases. The mean changes in HU/Gy were: 1.76 (SD=0.73) for the chest wall cohort, and 1.40 (SD=0.87) for the lung cohort. The median scan times post treatment were 21 and 12 months respectively. All 26 patients developed solid consolidation (scar-like radiographic opacities) within the exposed lung(s). Conclusion: Analysis of follow-up CTs revealed statistically significant correlations in HU-change/dose for two proton cohorts (lung and chest wall). Quantitatively, the late-phase changes we report broadly match published photon data. Further analysis of such radiographic changes, particularly via matched cohort studies drawing upon consistent imaging protocols, could play an

  9. Blog Posting After Lung Cancer Notification: Content Analysis of Blogs Written by Patients or Their Families.

    Science.gov (United States)

    Sato, Akira; Aramaki, Eiji; Shimamoto, Yumiko; Tanaka, Shiro; Kawakami, Koji

    2015-05-18

    The advent and spread of the Internet has changed the way societies communicate. A portion of information on the Internet may constitute an important source of information concerning the experiences and thoughts of patients and their families. Patients and their families use blogs to obtain updated information, search for alternative treatments, facilitate communication with other patients, and receive emotional support. However, much of this information has yet to be actively utilized by health care professionals. We analyzed health-related information in blogs from Japan, focusing on the feelings and satisfaction levels of lung cancer patients or their family members after being notified of their disease. We collected 100 blogs written in Japanese by patients (or their families) who had been diagnosed with lung cancer by a physician. These 100 blogs posts were searchable between June 1 and June 30, 2013. We focused on blog posts that addressed the lung cancer notification event. We analyzed the data using two different approaches (Analysis A and Analysis B). Analysis A was blog content analysis in which we analyzed the content addressing the disease notification event in each blog. Analysis B was patient's dissatisfaction and anxiety analysis. Detailed blog content regarding patient's dissatisfaction and anxiety at the individual sentence level was coded and analyzed. The 100 blog posts were written by 48 men, 46 women, and 6 persons whose sex was undisclosed. The average age of the blog authors was 52.4 years. With regard to cancer staging, there were 5 patients at Stage I, 3 patients at Stage II, 14 patients at Stage III, 21 patients at Stage IV, and 57 patients without a disclosed cancer stage. The results of Analysis A showed that the proportion of patients who were dissatisfied with the level of health care exceeded that of satisfied patients (22% vs 8%). From the 2499 sentences in the 100 blog posts analyzed, we identified expressions of dissatisfaction and

  10. Analysis of Prognostic Factors in 541 Female Patients with Advanced Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Meina WU

    2011-03-01

    Full Text Available Background and objective As there is a sharp increase in the incidence of lung cancer in women in recent years, it has brought broad concerns with its unique clinical and epidemiological characteristics and better prognosis. The aim of this study is to analyze the clinical data of women with advanced non-small cell lung cancer (NSCLC retrospectively to explore the prognostic factors. Methods Clinical data of 541 female patients with advanced NSCLC were collected and followed up till death. The primary endpoint is overall survival (OS. SPSS 11.0 statistical analysis software was used for univariate and multivariate analysis. Results The mean age is 59 years (20 years-86 years, adenocarcinoma account for 80.2% (434/541. The median OS was 15 months (95%CI: 13.87-16.13, and 1, 2, 5-year survival rates were 58.8%, 23.7% and 3.20% respectively. Univariate analysis showed that clinical stage, ECOG score, weight loss, clinical symptoms, liver/bone/brain metastasis and received more than one chemotherapy regimen, good response to the first-line chemotherapy, EGFR-TKI targeted therapy and radiotherapy treatment were significantly correlated with the OS and survival rate (P < 0.05. Combined with multivariate analysis, weight loss before treatment, ECOG score, received EGFR-TKI targeted therapy and response to first-line chemotherapy were independent prognostic factor for survival (P < 0.05. Conclusion There is a higher percentage of adenocarcinoma in female NSCLC. Weight loss before treatment, ECOG score, EGFR-TKI targeted therapy and response to first-line chemotherapy may become independent prognostic factors for survival of female patients with advanced NSCLC.

  11. Puget Sound Area Electric Reliability Plan. Appendix D, Conservation, Load Management and Fuel Switching Analysis : Draft Environmental Impact Statement.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1991-09-01

    Various conservation, load management, and fuel switching programs were considered as ways to reduce or shift system peak load. These programs operate at the end-use level, such as residential water heat. Figure D-1a shows what electricity consumption for water heat looks like on normal and extreme peak days. Load management programs, such as water heat control, are designed to reduce electricity consumption at the time of system peak. On the coldest day in average winter, system load peaks near 8:00 a.m. In a winter with extremely cold weather, electricity consumption increases fr all hours, and the system peak shifts to later in the morning. System load shapes in the Puget Sound area are shown in Figure D-1b for a normal winter peak day (February 2, 1988) and extreme peak day (February 3, 1989). Peak savings from any program are calculated to be the reduction in loads on the entire system at the hour of system peak. Peak savings for all programs are measured at 8:00 a.m. on a normal peak day and 9:00 a.m. on an extreme peak day. On extremely cold day, some water heat load shifts to much later in the morning, with less load available for shedding at the time of system peak. Models of hourly end-use consumption were constructed to simulate the impact of conservation, land management, and fuel switching programs on electricity consumption. Javelin, a time-series simulating package for personal computers, was chosen for the hourly analysis. Both a base case and a program case were simulated. 15 figs., 7 tabs.

  12. Temporal behavior of lung motion assested by xenon-127 scintigraphy using temporal Fourier analysis

    International Nuclear Information System (INIS)

    Susskind, H.; Tang, Y.N.; Bossuyt, A.; Cinotti, L.; Brill, A.B.

    1989-01-01

    Temporal Fourier Analysis (TFA) was applied to standard 127 Xe ventilation studies to determine the time-activity curves up to the third harmonic for a single composite respiratory cycle. A global respiratory index, RI 3 , defined as the ratio of the amplitude for the first three harmonics. Three nonobstructed subjects, two subjects with only small airway disease, five subjects with chronic ostructive pulmonary disease (COPD) and onne subject with restrictive lung disease were studied. Geometric mean values of posterior and anterior images gave a closer relationship between RI 3 and flow or volume parameters than either image alone. RI 3 of the first three harmonics correlated linearly with the values of 1-s forced expiratory volume (FEV 1 )(r 0.783, p 3 values for the five COPD subjects were significantly lower (t = 2.582, p 127 Xe ventilation data therefore appears to be a potentially useful, noninvasive, in vivo technique for evaluation of lung ventilation at the localized level. (author). 20 refs.; 6 figs.; 3 tabs

  13. Sound pressure level tools design used in occupational health by means of Labview software

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2015-01-01

    Conclusion: LabVIEW programming capabilities in the field of sound can be referred to the measurement of sound, frequency analysis, and sound control that actually the software acts like a sound level meter and sound analyzer. According to the mentioned features, we can use this software to analyze and process sound and vibration as a monitoring system.

  14. Risk factors and survival outcome for non-elective referral in non-small cell lung cancer patients--analysis based on the National Lung Cancer Audit.

    Science.gov (United States)

    Beckett, P; Tata, L J; Hubbard, R B

    2014-03-01

    Survival after diagnosis of lung cancer is poor and seemingly lower in the UK than other Western countries, due in large part to late presentation with advanced disease precluding curative treatment. Recent research suggests that around one-third of lung cancer patients reach specialist care after emergency presentation and have a worse survival outcome. Confirmation of these data and understanding which patients are affected may allow a targeted approach to improving outcomes. We used data from the UK National Lung Cancer Audit in a multivariate logistic regression model to quantify the association of non-elective referral in non-small cell lung cancer patients with covariates including age, sex, stage, performance status, co-morbidity and socioeconomic status and used the Kaplan-Meier method and Cox proportional hazards model to quantify survival by source of referral. In an analysis of 133,530 cases of NSCLC who presented 2006-2011, 19% of patients were referred non-electively (following an emergency admission to hospital or following an emergency presentation to A&E). This route of referral was strongly associated with more advanced disease stage (e.g. in Stage IV - OR: 2.34, 95% CI: 2.14-2.57, p<0.001) and worse performance status (e.g. in PS 4 - OR: 7.28, 95% CI: 6.75-7.86, p<0.001), but was also independently associated with worse socioeconomic status, and extremes of age. These patients were more likely to have died within 1 year of diagnosis (hazard ratio of 1.51 (95% CI: 1.49-1.54) after adjustment for key clinical variables. Our data confirm and quantify poorer survival in lung cancer patients who are referred non-electively to specialist care, which is more common in patients with poorer performance status, higher disease stage and less advantaged socioeconomic status. Work to tackle this late presentation should be urgently accelerated, since its realisation holds the promise of improved outcomes and better healthcare resource utilisation. Copyright

  15. Pulmonary lymphangioleiomyomatosis: Analysis of disease manifestation by region-based quantification of lung parenchyma

    Energy Technology Data Exchange (ETDEWEB)

    Theilig, D., E-mail: dorothea.theilig@charite.de [Charité, Universitätsmedizin Berlin, Department of Radiology, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin (Germany); Doellinger, F. [Charité, Universitätsmedizin Berlin, Department of Radiology, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin (Germany); Kuhnigk, J.M. [Fraunhofer MEVIS, Universitaetsallee 29, 28359 Bremen (Germany); Temmesfeld-Wollbrueck, B.; Huebner, R.H. [Charité, Department of Pneumology, Augustenburger Platz 1, 13353 Berlin (Germany); Schreiter, N.; Poellinger, A. [Charité, Universitätsmedizin Berlin, Department of Radiology, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin (Germany)

    2015-04-15

    Highlights: •The distribution of cystic lesions in LAM was evaluated with quantitative CT. •There were more cystic lesions in the central lung compared to peripheral areas. •Cystic changes were more frequent in apical two thirds compared to lower third. •Results might help to obviate the need for biopsy in more cases. -- Abstract: Purpose: Lymphangioleiomyomatosis (LAM) is characterized by proliferation of smooth muscle tissue that causes bronchial obstruction and secondary cystic destruction of lung parenchyma. The aim of this study was to evaluate the typical distribution of cystic defects in LAM with quantitative volumetric chest computed tomography (CT). Materials and methods: CT examinations of 20 patients with confirmed LAM were evaluated with region-based quantification of lung parenchyma. Additionally, 10 consecutive patients were identified who had recently undergone CT imaging of the lung at our institution, in which no pathologies of the lung were found, to serve as a control group. Each lung was divided into three regions (upper, middle and lower thirds) with identical number of slices. In addition, we defined a “peel” and “core” of the lung comprising the 2 cm subpleural space and the remaining inner lung area. Computerized detection of lung volume and relative emphysema was performed with the PULMO 3D software (v3.42, Fraunhofer MEVIS, Bremen, Germany). This software package enables the quantification of emphysematous lung parenchyma by calculating the pixel index, which is defined as the ratio of lung voxels with a density <−950 HU to the total number of voxels in the lung. Results: Cystic changes accounted for 0.1–39.1% of the total lung volume in patients with LAM. Disease manifestation in the central lung was significantly higher than in peripheral areas (peel median: 15.1%, core median: 20.5%; p = 0.001). Lower thirds of lung parenchyma showed significantly less cystic changes than upper and middle lung areas combined (lower

  16. The Sound of Science

    Science.gov (United States)

    Merwade, Venkatesh; Eichinger, David; Harriger, Bradley; Doherty, Erin; Habben, Ryan

    2014-01-01

    While the science of sound can be taught by explaining the concept of sound waves and vibrations, the authors of this article focused their efforts on creating a more engaging way to teach the science of sound--through engineering design. In this article they share the experience of teaching sound to third graders through an engineering challenge…

  17. Sounds Exaggerate Visual Shape

    Science.gov (United States)

    Sweeny, Timothy D.; Guzman-Martinez, Emmanuel; Ortega, Laura; Grabowecky, Marcia; Suzuki, Satoru

    2012-01-01

    While perceiving speech, people see mouth shapes that are systematically associated with sounds. In particular, a vertically stretched mouth produces a /woo/ sound, whereas a horizontally stretched mouth produces a /wee/ sound. We demonstrate that hearing these speech sounds alters how we see aspect ratio, a basic visual feature that contributes…

  18. Making Sound Connections

    Science.gov (United States)

    Deal, Walter F., III

    2007-01-01

    Sound provides and offers amazing insights into the world. Sound waves may be defined as mechanical energy that moves through air or other medium as a longitudinal wave and consists of pressure fluctuations. Humans and animals alike use sound as a means of communication and a tool for survival. Mammals, such as bats, use ultrasonic sound waves to…

  19. Effect of nocturnal sound reduction on the incidence of delirium in intensive care unit patients: An interrupted time series analysis

    NARCIS (Netherlands)

    van de Pol, Ineke; van Iterson, Mat; Maaskant, Jolanda

    2017-01-01

    Delirium in critically-ill patients is a common multifactorial disorder that is associated with various negative outcomes. It is assumed that sleep disturbances can result in an increased risk of delirium. This study hypothesized that implementing a protocol that reduces overall nocturnal sound

  20. Microflown based monopole sound sources for reciprocal measurements

    NARCIS (Netherlands)

    Bree, H.E. de; Basten, T.G.H.

    2008-01-01

    Monopole sound sources (i.e. omni directional sound sources with a known volume velocity) are essential for reciprocal measurements used in vehicle interior panel noise contribution analysis. Until recently, these monopole sound sources use a sound pressure transducer sensor as a reference sensor. A

  1. The potential diagnostic power of circulating tumor cell analysis for non-small-cell lung cancer.

    Science.gov (United States)

    Ross, Kirsty; Pailler, Emma; Faugeroux, Vincent; Taylor, Melissa; Oulhen, Marianne; Auger, Nathalie; Planchard, David; Soria, Jean-Charles; Lindsay, Colin R; Besse, Benjamin; Vielh, Philippe; Farace, Françoise

    2015-01-01

    In non-small-cell lung cancer (NSCLC), genotyping tumor biopsies for targetable somatic alterations has become routine practice. However, serial biopsies have limitations: they may be technically difficult or impossible and could incur serious risks to patients. Circulating tumor cells (CTCs) offer an alternative source for tumor analysis that is easily accessible and presents the potential to identify predictive biomarkers to tailor therapies on a personalized basis. Examined here is our current knowledge of CTC detection and characterization in NSCLC and their potential role in EGFR-mutant, ALK-rearranged and ROS1-rearranged patients. This is followed by discussion of the ongoing issues such as the question of CTC partnership as diagnostic tools in NSCLC.

  2. Variation compensation and analysis on diaphragm curvature analysis for emphysema quantification on whole lung CT scans

    Science.gov (United States)

    Keller, Brad M.; Reeves, Anthony P.; Barr, R. Graham; Yankelevitz, David F.; Henschke, Claudia I.

    2010-03-01

    CT scans allow for the quantitative evaluation of the anatomical bases of emphysema. Recently, a non-density based geometric measurement of lung diagphragm curvature has been proposed as a method for the quantification of emphysema from CT. This work analyzes variability of diaphragm curvature and evaluates the effectiveness of a compensation methodology for the reduction of this variability as compared to emphysema index. Using a dataset of 43 scan-pairs with less than a 100 day time-interval between scans, we find that the diaphragm curvature had a trend towards lower overall variability over emphysema index (95% CI:-9.7 to + 14.7 vs. -15.8 to +12.0), and that the variation of both measures was reduced after compensation. We conclude that the variation of the new measure can be considered comparable to the established measure and the compensation can reduce the apparent variation of quantitative measures successfully.

  3. Quantitative Proteomic Analysis of Optimal Cutting Temperature (OCT) Embedded Core-Needle Biopsy of Lung Cancer

    Science.gov (United States)

    Zhao, Xiaozheng; Huffman, Kenneth E.; Fujimoto, Junya; Canales, Jamie Rodriguez; Girard, Luc; Nie, Guangjun; Heymach, John V.; Wistuba, Igacio I.; Minna, John D.; Yu, Yonghao

    2017-10-01

    With recent advances in understanding the genomic underpinnings and oncogenic drivers of pathogenesis in different subtypes, it is increasingly clear that proper pretreatment diagnostics are essential for the choice of appropriate treatment options for non-small cell lung cancer (NSCLC). Tumor tissue preservation in optimal cutting temperature (OCT) compound is commonly used in the surgical suite. However, proteins recovered from OCT-embedded specimens pose a challenge for LC-MS/MS experiments, due to the large amounts of polymers present in OCT. Here we present a simple workflow for whole proteome analysis of OCT-embedded NSCLC tissue samples, which involves a simple trichloroacetic acid precipitation step. Comparisons of protein recovery between frozen versus OCT-embedded tissue showed excellent consistency with more than 9200 proteins identified. Using an isobaric labeling strategy, we quantified more than 5400 proteins in tumor versus normal OCT-embedded core needle biopsy samples. Gene ontology analysis indicated that a number of proliferative as well as squamous cell carcinoma (SqCC) marker proteins were overexpressed in the tumor, consistent with the patient's pathology based diagnosis of "poorly differentiated SqCC". Among the most downregulated proteins in the tumor sample, we noted a number of proteins with potential immunomodulatory functions. Finally, interrogation of the aberrantly expressed proteins using a candidate approach and cross-referencing with publicly available databases led to the identification of potential druggable targets in DNA replication and DNA damage repair pathways. We conclude that our approach allows LC-MS/MS proteomic analyses on OCT-embedded lung cancer specimens, opening the way to bring powerful proteomics into the clinic. [Figure not available: see fulltext.

  4. Retrospective analysis of icotinib neoadjuvant therapy of 63 lung cancer patients.

    Science.gov (United States)

    Wang, T; Liu, Y; Zhou, B; Hao, S; Wang, Z; Liang, N; Liu, J; Wang, S

    2017-01-01

    This study aims to explore the feasibility of icotinib neoadjuvant therapy for nonsmall cell lung cancer (NSCLC). This was a retrospective analysis of the clinical data for 63 NSCLC patients (61 cases of adenocarcinoma and two cases of squamous cell carcinoma) receiving surgical resection of lung lesions after oral intake of icotinib from December 2011 to November 2013 in the PLA General Hospital. Preoperative oral intake of the patients was icotinib 125 mg tid, drug side effects were evaluated according to the American National Cancer Institute Common Toxicity Criteria Version 4.0; computed tomography scan was done on the day taking medicine and 2 weeks later to determine tumor changes. After oral intake of Icotinib for 2 to 22 weeks (5 cases for 2 weeks,13 cases for 3 to 22 weeks), all patients receive surgical resection of lung cancer lesions, and testing of removed tumor to evaluate the epidermal growth factor receptor (EGFR) gene mutation status was performed by fluorescence polymerase chain reaction. The patients with sensitive EGFR mutations receive Icotinib as postoperative adjuvant therapy. Side effects of medication within 2 weeks included rash (44.4%, 28/63), dry skin (34.9%, 22/63), diarrhea (14.3%, 9/63), and oral ulcer (1.6%, 1/63); there were no icotinib-associated thoracic surgery complications during the perioperational period. 71.4% patients (45/63) achieve an average reduction of 23.5% ±10.7%(10%-53.5%) after 2 weeks medication of Icotinib(regressive tumor[RT]) .28.6% patients(18/63) achieve stable tumor(ST),enlargement of 8.7% to reduction of 8.7% of the maximum diameter of lung cancer after 2 weeks medication of Icotinib. Of the RT group, 68.9% (31/45) of the tumors were detected with EGFR-sensitive mutation (exon 19 or 21 mutation), 24.4% (11/45) with wild-type EGFR, and three cases of exon 20 mutation. Of the ST group, 77.8% (14/18) were detected with wild-type EGFR, three cases of exon 20 mutation, and one case of exon 19 deletion mutation

  5. Little Sounds

    Directory of Open Access Journals (Sweden)

    Baker M. Bani-Khair

    2017-10-01

    Full Text Available The Spider and the Fly   You little spider, To death you aspire... Or seeking a web wider, To death all walking, No escape you all fighters… Weak and fragile in shape and might, Whatever you see in the horizon, That is destiny whatever sight. And tomorrow the spring comes, And the flowers bloom, And the grasshopper leaps high, And the frogs happily cry, And the flies smile nearby, To that end, The spider has a plot, To catch the flies by his net, A mosquito has fallen down in his net, Begging him to set her free, Out of that prison, To her freedom she aspires, Begging...Imploring...crying,  That is all what she requires, But the spider vows never let her free, His power he admires, Turning blind to light, And with his teeth he shall bite, Leaving her in desperate might, Unable to move from site to site, Tied up with strings in white, Wrapped up like a dead man, Waiting for his grave at night,   The mosquito says, Oh little spider, A stronger you are than me in power, But listen to my words before death hour, Today is mine and tomorrow is yours, No escape from death... Whatever the color of your flower…     Little sounds The Ant The ant is a little creature with a ferocious soul, Looking and looking for more and more, You can simply crush it like dead mold, Or you can simply leave it alone, I wonder how strong and strong they are! Working day and night in a small hole, Their motto is work or whatever you call… A big boon they have and joy in fall, Because they found what they store, A lesson to learn and memorize all in all, Work is something that you should not ignore!   The butterfly: I’m the butterfly Beautiful like a blue clear sky, Or sometimes look like snow, Different in colors, shapes and might, But something to know that we always die, So fragile, weak and thin, Lighter than a glimpse and delicate as light, Something to know for sure… Whatever you have in life and all these fields, You are not happier than a butterfly

  6. Using gEUD based plan analysis method to evaluate proton vs. photon plans for lung cancer radiation therapy.

    Science.gov (United States)

    Xiao, Zhiyan; Zou, Wei J; Chen, Ting; Yue, Ning J; Jabbour, Salma K; Parikh, Rahul; Zhang, Miao

    2018-03-01

    The goal of this study was to exam the efficacy of current DVH based clinical guidelines draw from photon experience for lung cancer radiation therapy on proton therapy. Comparison proton plans and IMRT plans were generated for 10 lung patients treated in our proton facility. A gEUD based plan evaluation method was developed for plan evaluation. This evaluation method used normal lung gEUD(a) curve in which the model parameter "a" was sampled from the literature reported value. For all patients, the proton plans delivered lower normal lung V 5 Gy with similar V 20 Gy and similar target coverage. Based on current clinical guidelines, proton plans were ranked superior to IMRT plans for all 10 patients. However, the proton and IMRT normal lung gEUD(a) curves crossed for 8 patients within the tested range of "a", which means there was a possibility that proton plan would be worse than IMRT plan for lung sparing. A concept of deficiency index (DI) was introduced to quantify the probability of proton plans doing worse than IMRT plans. By applying threshold on DI, four patients' proton plan was ranked inferior to the IMRT plan. Meanwhile if a threshold to the location of curve crossing was applied, 6 patients' proton plan was ranked inferior to the IMRT plan. The contradictory ranking results between the current clinical guidelines and the gEUD(a) curve analysis demonstrated there is potential pitfalls by applying photon experience directly to the proton world. A comprehensive plan evaluation based on radio-biological models should be carried out to decide if a lung patient would really be benefit from proton therapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  7. Lung cancer

    International Nuclear Information System (INIS)

    Aisner, J.

    1985-01-01

    This book contains 13 chapters. Some of the chapter titles are: The Pathology of Lung Cancer; Radiotherapy for Non-Small-Cell Cancer of the Lung; Chemotherapy for Non-Small-Cell Lung Cancer; Immunotherapy in the Management of Lung Cancer; Preoperative Staging and Surgery for Non-Small-Cell Lung Cancer; and Prognostic Factors in Lung Cancer

  8. Radon, cigarette smoke, and lung cancer: A re-analysis of the Colorado Plateau uranium miners' data [see comments

    International Nuclear Information System (INIS)

    Moolgavkar, S.H.; Luebeck, E.G.; Krewski, D.; Zielinski, J.M.

    1993-01-01

    Much of our knowledge regarding the interaction of radon and tobacco smoke in the etiology of human lung cancer derives from studies of uranium miners. In this article, we present a re-analysis of lung cancer mortality in the Colorado Plateau miners' cohort within the framework of the two-mutation clonal expansion model of carcinogenesis. This analysis takes into account the patterns of exposure to radon and cigarette smoke experienced by individuals in the cohort. A simultaneous re-analysis of the British doctors' cohort indicated that those model parameters relating to the effects of tobacco were comparable in the two data sets. We found no evidence of interaction between radon and tobacco smoke with respect to their joint effect on the first or second stage mutation rates or on the rate of proliferation of initiated cells. The age-specific relative risks associated with joint exposure to radon and cigarette smoke, however, were supra-additive but submultiplicative. The analysis also confirmed that fractionation of radon exposures leads to higher lung cancer risks. Finally, we present some estimates of lung cancer risk from environmental radon exposure for non-smokers and smokers

  9. An analysis of anatomic landmark mobility and setup errors in radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Samson, M.J.; Soernsen de Koste, J.R. van; Boer, J.C.J. de; Tankink, J.J.; Verstraate, M.B.J.; Essers, M.; Visser, A.G.; Senan, S.

    1997-01-01

    Purpose: To identify visible structures in the thorax which exhibit little internal motion during irradiation and, to determine random and systematic setup deviations in lung cancer patients with the use of these structures. Methods: Ten patients with lung cancer were set up in the supine position, and aligned using lasers. No immobilization devices were used. With an electronic portal imaging device (Siemens Beam View PLUS ), 12 sequential images (exposure 0.54 sec.; processing time 1.5 sec.) were obtained during a single fraction of radiotherapy. These 'movie loops' were generated for the A-P fields during each of 3-5 fractions. In order to determine the mobility of internal structures during each fraction, visible structures such as the trachea, carina, the upper chest wall, aortic arch, clavicle and paraspinal line were contoured manually in each image and matched with the first image of the corresponding movie loop by means of a cross-correlation algorithm. Translations in the cranial and lateral directions and in-plane rotations were determined for each structure separately. As the reference image represents a random position, relative movements were determined by comparing the translations and rotation for every image to the calculated means per movie-loop. Standard deviations of the relative movements were determined for each structure and each patient. Patient setup was evaluated for 15 patients with lung cancer. Setup was not corrected at any time during the treatment. The electronic portal images of each fraction were matched with the digitized simulator films by using a combination of the structures which had been determined to be relatively stable in the infra-fractional analysis. Results: In the infra-fractional analysis 120 to 380 matches were made per structure (a total of 1400). The standard deviation (SD) of translations in the lateral direction was small (≤1 mm) for the trachea, thoracic wall, paraspinal line and aortic arch. This was also the

  10. Analysis of the risk factors for exposure of the lung to low irradiation doses

    International Nuclear Information System (INIS)

    Hogeweg, B.

    1986-02-01

    In this report a description is presented of the risk factors for induction of lungtumours. The contribution of natural radioactivity from uranium and thorium to the lungs is mainly caused by inhalation of alpha-emitting radon and thorium daughter products. Apart from exposure by inhalation the lungs are also exposed to external radiation. For internal as well as external exposure a value of 10 -3 lungcancers per Sv lung dose equivalence is found to be acceptable for the riskfactor. (Auth.)

  11. Barriers to uptake among high-risk individuals declining participation in lung cancer screening: a mixed methods analysis of the UK Lung Cancer Screening (UKLS) trial.

    Science.gov (United States)

    Ali, Noor; Lifford, Kate J; Carter, Ben; McRonald, Fiona; Yadegarfar, Ghasem; Baldwin, David R; Weller, David; Hansell, David M; Duffy, Stephen W; Field, John K; Brain, Kate

    2015-07-14

    The current study aimed to identify the barriers to participation among high-risk individuals in the UK Lung Cancer Screening (UKLS) pilot trial. The UKLS pilot trial is a randomised controlled trial of low-dose CT (LDCT) screening that has recruited high-risk people using a population approach in the Cambridge and Liverpool areas. High-risk individuals aged 50-75 years were invited to participate in UKLS. Individuals were excluded if a LDCT scan was performed within the last year, if they were unable to provide consent, or if LDCT screening was unable to be carried out due to coexisting comorbidities. Statistical associations between individual characteristics and UKLS uptake were examined using multivariable regression modelling. In those who completed a non-participation questionnaire (NPQ), thematic analysis of free-text data was undertaken to identify reasons for not taking part, with subsequent exploratory linkage of key themes to risk factors for non-uptake. Comparative data were available from 4061 high-risk individuals who consented to participate in the trial and 2756 who declined participation. Of those declining participation, 748 (27.1%) completed a NPQ. Factors associated with non-uptake included: female gender (OR=0.64, pemotional barriers. Smokers were more likely to report emotional barriers to participation. A profile of risk factors for non-participation in lung screening has emerged, with underlying reasons largely relating to practical and emotional barriers. Strategies for engaging high-risk, hard-to-reach groups are critical for the equitable uptake of a potential future lung cancer screening programme. The UKLS trial was registered with the International Standard Randomised Controlled Trial Register under the reference 78513845. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Analysis of radon-induced lung cancer risk by a stochastic state-vector model of radiation carcinogenesis

    International Nuclear Information System (INIS)

    Crawford-Brown, Douglas J.; Hofmann, Werner

    2002-01-01

    A biologically based state-vector model (SVM) of radiation carcinogenesis has been extended to incorporate stochasticity of cellular transitions and specific in vivo irradiation conditions in the lungs. Dose-rate-dependent cellular transitions related to the formation of double-stranded DNA breaks, repair of breaks, interactions (translocations) between breaks, fixation of breaks, cellular inactivation, stimulated mitosis and promotion through loss of intercellular communication are simulated by Monte Carlo methods. The stochastic SVM has been applied to the analysis of lung cancer incidence in uranium miners exposed to alpha-emitting radon progeny. When incorporating in vivo features of cell differentiation, stimulated cell division and heterogeneity of cellular doses into the model, excellent agreement between epidemiological data and modelling results could be obtained. At low doses, the model predicts a non-linear dose-response relationship; e.g., computed lung cancer risk at 20 WLM is about half of current lung cancer estimates based on the linear hypothesis. The model also predicts a slight dose rate effect; e.g., at a cumulative exposure of 20 WLM, calculated lung cancer incidence for an exposure rate 0.27 WLM/year (assuming an exposure time of 73 years) is smaller by a factor of 1.2 than that for an exposure rate of 10 WLM/year. (author)

  13. Cross-Cancer Genome-Wide Analysis of Lung, Ovary, Breast, Prostate, and Colorectal Cancer Reveals Novel Pleiotropic Associations.

    Science.gov (United States)

    Fehringer, Gordon; Kraft, Peter; Pharoah, Paul D; Eeles, Rosalind A; Chatterjee, Nilanjan; Schumacher, Fredrick R; Schildkraut, Joellen M; Lindström, Sara; Brennan, Paul; Bickeböller, Heike; Houlston, Richard S; Landi, Maria Teresa; Caporaso, Neil; Risch, Angela; Amin Al Olama, Ali; Berndt, Sonja I; Giovannucci, Edward L; Grönberg, Henrik; Kote-Jarai, Zsofia; Ma, Jing; Muir, Kenneth; Stampfer, Meir J; Stevens, Victoria L; Wiklund, Fredrik; Willett, Walter C; Goode, Ellen L; Permuth, Jennifer B; Risch, Harvey A; Reid, Brett M; Bezieau, Stephane; Brenner, Hermann; Chan, Andrew T; Chang-Claude, Jenny; Hudson, Thomas J; Kocarnik, Jonathan K; Newcomb, Polly A; Schoen, Robert E; Slattery, Martha L; White, Emily; Adank, Muriel A; Ahsan, Habibul; Aittomäki, Kristiina; Baglietto, Laura; Blomquist, Carl; Canzian, Federico; Czene, Kamila; Dos-Santos-Silva, Isabel; Eliassen, A Heather; Figueroa, Jonine D; Flesch-Janys, Dieter; Fletcher, Olivia; Garcia-Closas, Montserrat; Gaudet, Mia M; Johnson, Nichola; Hall, Per; Hazra, Aditi; Hein, Rebecca; Hofman, Albert; Hopper, John L; Irwanto, Astrid; Johansson, Mattias; Kaaks, Rudolf; Kibriya, Muhammad G; Lichtner, Peter; Liu, Jianjun; Lund, Eiliv; Makalic, Enes; Meindl, Alfons; Müller-Myhsok, Bertram; Muranen, Taru A; Nevanlinna, Heli; Peeters, Petra H; Peto, Julian; Prentice, Ross L; Rahman, Nazneen; Sanchez, Maria Jose; Schmidt, Daniel F; Schmutzler, Rita K; Southey, Melissa C; Tamimi, Rulla; Travis, Ruth C; Turnbull, Clare; Uitterlinden, Andre G; Wang, Zhaoming; Whittemore, Alice S; Yang, Xiaohong R; Zheng, Wei; Buchanan, Daniel D; Casey, Graham; Conti, David V; Edlund, Christopher K; Gallinger, Steven; Haile, Robert W; Jenkins, Mark; Le Marchand, Loïc; Li, Li; Lindor, Noralene M; Schmit, Stephanie L; Thibodeau, Stephen N; Woods, Michael O; Rafnar, Thorunn; Gudmundsson, Julius; Stacey, Simon N; Stefansson, Kari; Sulem, Patrick; Chen, Y Ann; Tyrer, Jonathan P; Christiani, David C; Wei, Yongyue; Shen, Hongbing; Hu, Zhibin; Shu, Xiao-Ou; Shiraishi, Kouya; Takahashi, Atsushi; Bossé, Yohan; Obeidat, Ma'en; Nickle, David; Timens, Wim; Freedman, Matthew L; Li, Qiyuan; Seminara, Daniela; Chanock, Stephen J; Gong, Jian; Peters, Ulrike; Gruber, Stephen B; Amos, Christopher I; Sellers, Thomas A; Easton, Douglas F; Hunter, David J; Haiman, Christopher A; Henderson, Brian E; Hung, Rayjean J

    2016-09-01

    Identifying genetic variants with pleiotropic associations can uncover common pathways influencing multiple cancers. We took a two-stage approach to conduct genome-wide association studies for lung, ovary, breast, prostate, and colorectal cancer from the GAME-ON/GECCO Network (61,851 cases, 61,820 controls) to identify pleiotropic loci. Findings were replicated in independent association studies (55,789 cases, 330,490 controls). We identified a novel pleiotropic association at 1q22 involving breast and lung squamous cell carcinoma, with eQTL analysis showing an association with ADAM15/THBS3 gene expression in lung. We also identified a known breast cancer locus CASP8/ALS2CR12 associated with prostate cancer, a known cancer locus at CDKN2B-AS1 with different variants associated with lung adenocarcinoma and prostate cancer, and confirmed the associations of a breast BRCA2 locus with lung and serous ovarian cancer. This is the largest study to date examining pleiotropy across multiple cancer-associated loci, identifying common mechanisms of cancer development and progression. Cancer Res; 76(17); 5103-14. ©2016 AACR. ©2016 American Association for Cancer Research.

  14. Cross-cancer genome-wide analysis of lung, ovary, breast, prostate and colorectal cancer reveals novel pleiotropic associations

    Science.gov (United States)

    Fehringer, Gordon; Kraft, Peter; Pharoah, Paul D.; Eeles, Rosalind A.; Chatterjee, Nilanjan; Schumacher, Fred; Schildkraut, Joellen; Lindström, Sara; Brennan, Paul; Bickeböller, Heike; Houlston, Richard S.; Landi, Maria Teresa; Caporaso, Neil; Risch, Angela; Olama, Ali Amin Al; Berndt, Sonja I; Giovannucci, Edward; Grönberg, Henrik; Kote-Jarai, Zsofia; Ma, Jing; Muir, Kenneth; Stampfer, Meir; Stevens, Victoria L.; Wiklund, Fredrik; Willett, Walter; Goode, Ellen L.; Permuth, Jennifer; Risch, Harvey A.; Reid, Brett M.; Bezieau, Stephane; Brenner, Hermann; Chan, Andrew T.; Chang-Claude, Jenny; Hudson, Thomas J.; Kocarnik, Jonathan K.; Newcomb, Polly A.; Schoen, Robert E.; Slattery, Martha L.; White, Emily; Adank, Muriel A.; Ahsan, Habibul; Aittomäki, Kristiina; Baglietto, Laura; Blomquist, Carl; Canzian, Federico; Czene, Kamila; dos-Santos-Silva, Isabel; Eliassen, A. Heather; Figueroa, Jonine; Flesch-Janys, Dieter; Fletcher, Olivia; Garcia-Closas, Montserrat; Gaudet, Mia M.; Johnson, Nichola; Hall, Per; Hazra, Aditi; Hein, Rebecca; Hofman, Albert; Hopper, John L.; Irwanto, Astrid; Johansson, Mattias; Kaaks, Rudolf; Kibriya, Muhammad G.; Lichtner, Peter; Liu, Jianjun; Lund, Eiliv; Makalic, Enes; Meindl, Alfons; Müller-Myhsok, Bertram; Muranen, Taru A.; Nevanlinna, Heli; Peeters, Petra H.; Peto, Julian; Prentice, Ross L.; Rahman, Nazneen; Sanchez, Maria Jose; Schmidt, Daniel F.; Schmutzler, Rita K.; Southey, Melissa C.; Tamimi, Rulla; Travis, Ruth C.; Turnbull, Clare; Uitterlinden, Andre G.; Wang, Zhaoming; Whittemore, Alice S.; Yang, Xiaohong R.; Zheng, Wei; Rafnar, Thorunn; Gudmundsson, Julius; Stacey, Simon N.; Stefansson, Kari; Sulem, Patrick; Chen, Y. Ann; Tyrer, Jonathan P.; Christiani, David C.; Wei, Yongyue; Shen, Hongbing; Hu, Zhibin; Shu, Xiao-Ou; Shiraishi, Kouya; Takahashi, Atsushi; Bossé, Yohan; Obeidat, Ma’en; Nickle, David; Timens, Wim; Freedman, Matthew L.; Li, Qiyuan; Seminara, Daniela; Chanock, Stephen J.; Gong, Jian; Peters, Ulrike; Gruber, Stephen B.; Amos, Christopher I.; Sellers, Thomas A.; Easton, Douglas F.; Hunter, David J.; Haiman, Christopher A.; Henderson, Brian E.; Hung, Rayjean J.

    2016-01-01

    Identifying genetic variants with pleiotropic associations can uncover common pathways influencing multiple cancers. We took a two-staged approach to conduct genome-wide association studies for lung, ovary, breast, prostate and colorectal cancer from the GAME-ON/GECCO Network (61,851 cases, 61,820 controls) to identify pleiotropic loci. Findings were replicated in independent association studies (55,789 cases, 330,490 controls). We identified a novel pleiotropic association at 1q22 involving breast and lung squamous cell carcinoma, with eQTL analysis showing an association with ADAM15/THBS3 gene expression in lung. We also identified a known breast cancer locus CASP8/ALS2CR12 associated with prostate cancer, a known cancer locus at CDKN2B-AS1 with different variants associated with lung adenocarcinoma and prostate cancer and confirmed the associations of a breast BRCA2 locus with lung and serous ovarian cancer. This is the largest study to date examining pleiotropy across multiple cancer-associated loci, identifying common mechanisms of cancer development and progression. PMID:27197191

  15. Deep Sequence Analysis of Non-Small Cell Lung Cancer: Integrated Analysis of Gene Expression, Alternative Splicing, and Single Nucleotide Variations in Lung Adenocarcinomas with and without Oncogenic KRAS Mutations

    International Nuclear Information System (INIS)

    Kalari, Krishna R.; Rossell, David; Necela, Brian M.; Asmann, Yan W.; Nair, Asha

    2012-01-01

    KRAS mutations are highly prevalent in non-small cell lung cancer (NSCLC), and tumors harboring these mutations tend to be aggressive and resistant to chemotherapy. We used next-generation sequencing technology to identify pathways that are specifically altered in lung tumors harboring a KRAS mutation. Paired-end RNA-sequencing of 15 primary lung adenocarcinoma tumors (8 harboring mutant KRAS and 7 with wild-type KRAS) were performed. Sequences were mapped to the human genome, and genomic features, including differentially expressed genes, alternate splicing isoforms and single nucleotide variants, were determined for tumors with and without KRAS mutation using a variety of computational methods. Network analysis was carried out on genes showing differential expression (374 genes), alternate splicing (259 genes), and SNV-related changes (65 genes) in NSCLC tumors harboring a KRAS mutation. Genes exhibiting two or more connections from the lung adenocarcinoma network were used to carry out integrated pathway analysis. The most significant signaling pathways identified through this analysis were the NFκB, ERK1/2, and AKT pathways. A 27 gene mutant KRAS-specific sub network was extracted based on gene–gene connections from the integrated network, and interrogated for druggable targets. Our results confirm previous evidence that mutant KRAS tumors exhibit activated NFκB, ERK1/2, and AKT pathways and may be preferentially sensitive to target therapeutics toward these pathways. In addition, our analysis indicates novel, previously unappreciated links between mutant KRAS and the TNFR and PPARγ signaling pathways, suggesting that targeted PPARγ antagonists and TNFR inhibitors may be useful therapeutic strategies for treatment of mutant KRAS lung tumors. Our study is the first to integrate genomic features from RNA-Seq data from NSCLC and to define a first draft genomic landscape model that is unique to tumors with oncogenic KRAS mutations.

  16. Gene Expression Analysis to Assess the Relevance of Rodent Models to Human Lung Injury.

    Science.gov (United States)

    Sweeney, Timothy E; Lofgren, Shane; Khatri, Purvesh; Rogers, Angela J

    2017-08-01

    The relevance of animal models to human diseases is an area of intense scientific debate. The degree to which mouse models of lung injury recapitulate human lung injury has never been assessed. Integrating data from both human and animal expression studies allows for increased statistical power and identification of conserved differential gene expression across organisms and conditions. We sought comprehensive integration of gene expression data in experimental acute lung injury (ALI) in rodents compared with humans. We performed two separate gene expression multicohort analyses to determine differential gene expression in experimental animal and human lung injury. We used correlational and pathway analyses combined with external in vitro gene expression data to identify both potential drivers of underlying inflammation and therapeutic drug candidates. We identified 21 animal lung tissue datasets and three human lung injury bronchoalveolar lavage datasets. We show that the metasignatures of animal and human experimental ALI are significantly correlated despite these widely varying experimental conditions. The gene expression changes among mice and rats across diverse injury models (ozone, ventilator-induced lung injury, LPS) are significantly correlated with human models of lung injury (Pearson r = 0.33-0.45, P human lung injury. Predicted therapeutic targets, peptide ligand signatures, and pathway analyses are also all highly overlapping. Gene expression changes are similar in animal and human experimental ALI, and provide several physiologic and therapeutic insights to the disease.

  17. Comparative analysis of the mechanical signals in lung development and compensatory growth.

    Science.gov (United States)

    Hsia, Connie C W

    2017-03-01

    This review compares the manner in which physical stress imposed on the parenchyma, vasculature and thorax and the thoraco-pulmonary interactions, drive both developmental and compensatory lung growth. Re-initiation of anatomical lung growth in the mature lung is possible when the loss of functioning lung units renders the existing physiologic-structural reserves insufficient for maintaining adequate function and physical stress on the remaining units exceeds a critical threshold. The appropriate spatial and temporal mechanical interrelationships and the availability of intra-thoracic space, are crucial to growth initiation, follow-on remodeling and physiological outcome. While the endogenous potential for compensatory lung growth is retained and may be pharmacologically augmented, supra-optimal mechanical stimulation, unbalanced structural growth, or inadequate remodeling may limit functional gain. Finding ways to optimize the signal-response relationships and resolve structure-function discrepancies are major challenges that must be overcome before the innate compensatory ability could be fully realized. Partial pneumonectomy reproducibly removes a known fraction of functioning lung units and remains the most robust model for examining the adaptive mechanisms, structure-function consequences and plasticity of the remaining functioning lung units capable of regeneration. Fundamental mechanical stimulus-response relationships established in the pneumonectomy model directly inform the exploration of effective approaches to maximize compensatory growth and function in chronic destructive lung diseases, transplantation and bioengineered lungs.

  18. A stethoscope with wavelet separation of cardiac and respiratory sounds for real time telemedicine implemented on field-programmable gate array

    Science.gov (United States)

    Castro, Víctor M.; Muñoz, Nestor A.; Salazar, Antonio J.

    2015-01-01

    Auscultation is one of the most utilized physical examination procedures for listening to lung, heart and intestinal sounds during routine consults and emergencies. Heart and lung sounds overlap in the thorax. An algorithm was used to separate them based on the discrete wavelet transform with multi-resolution analysis, which decomposes the signal into approximations and details. The algorithm was implemented in software and in hardware to achieve real-time signal separation. The heart signal was found in detail eight and the lung signal in approximation six. The hardware was used to separate the signals with a delay of 256 ms. Sending wavelet decomposition data - instead of the separated full signa - allows telemedicine applications to function in real time over low-bandwidth communication channels.

  19. Everolimus in advanced, progressive, well-differentiated, non-functional neuroendocrine tumors: RADIANT-4 lung subgroup analysis.

    Science.gov (United States)

    Fazio, Nicola; Buzzoni, Roberto; Delle Fave, Gianfranco; Tesselaar, Margot E; Wolin, Edward; Van Cutsem, Eric; Tomassetti, Paola; Strosberg, Jonathan; Voi, Maurizio; Bubuteishvili-Pacaud, Lida; Ridolfi, Antonia; Herbst, Fabian; Tomasek, Jiri; Singh, Simron; Pavel, Marianne; Kulke, Matthew H; Valle, Juan W; Yao, James C

    2018-01-01

    In the phase III RADIANT-4 study, everolimus improved median progression-free survival (PFS) by 7.1 months in patients with advanced, progressive, well-differentiated (grade 1 or grade 2), non-functional lung or gastrointestinal neuroendocrine tumors (NETs) vs placebo (hazard ratio, 0.48; 95% confidence interval [CI], 0.35-0.67; P < .00001). This exploratory analysis reports the outcomes of the subgroup of patients with lung NETs. In RADIANT-4, patients were randomized (2:1) to everolimus 10 mg/d or placebo, both with best supportive care. This is a post hoc analysis of the lung subgroup with PFS, by central radiology review, as the primary endpoint; secondary endpoints included objective response rate and safety measures. Ninety of the 302 patients enrolled in the study had primary lung NET (everolimus, n = 63; placebo, n = 27). Median PFS (95% CI) by central review was 9.2 (6.8-10.9) months in the everolimus arm vs 3.6 (1.9-5.1) months in the placebo arm (hazard ratio, 0.50; 95% CI, 0.28-0.88). More patients who received everolimus (58%) experienced tumor shrinkage compared with placebo (13%). Most frequently reported (≥5% incidence) grade 3-4 drug-related adverse events (everolimus vs. placebo) included stomatitis (11% vs. 0%), hyperglycemia (10% vs. 0%), and any infections (8% vs. 0%). In patients with advanced, progressive, well-differentiated, non-functional lung NET, treatment with everolimus was associated with a median PFS improvement of 5.6 months, with a safety profile similar to that of the overall RADIANT-4 cohort. These results support the use of everolimus in patients with advanced, non-functional lung NET. The trial is registered with ClinicalTrials.gov (no. NCT01524783). © 2017 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  20. Making fictions sound real - On film sound, perceptual realism and genre

    Directory of Open Access Journals (Sweden)

    Birger Langkjær

    2010-05-01

    Full Text Available This article examines the role that sound plays in making fictions perceptually real to film audiences, whether these fictions are realist or non-realist in content and narrative form. I will argue that some aspects of film sound practices and the kind of experiences they trigger are related to basic rules of human perception, whereas others are more properly explained in relation to how aesthetic devices, including sound, are used to characterise the fiction and thereby make it perceptually real to its audience. Finally, I will argue that not all genres can be defined by a simple taxonomy of sounds. Apart from an account of the kinds of sounds that typically appear in a specific genre, a genre analysis of sound may also benefit from a functionalist approach that focuses on how sounds can make both realist and non-realist aspects of genres sound real to audiences.

  1. Making fictions sound real - On film sound, perceptual realism and genre

    Directory of Open Access Journals (Sweden)

    Birger Langkjær

    2009-09-01

    Full Text Available This article examines the role that sound plays in making fictions perceptually real to film audiences, whether these fictions are realist or non-realist in content and narrative form. I will argue that some aspects of film sound practices and the kind of experiences they trigger are related to basic rules of human perception, whereas others are more properly explained in relation to how aesthetic devices, including sound, are used to characterise the fiction and thereby make it perceptually real to its audience. Finally, I will argue that not all genres can be defined by a simple taxonomy of sounds. Apart from an account of the kinds of sounds that typically appear in a specific genre, a genre analysis of sound may also benefit from a functionalist approach that focuses on how sounds can make both realist and non-realist aspects of genres sound real to audiences.

  2. An analysis of the clinical features of lung cancer in patients with connective tissue diseases.

    Science.gov (United States)

    Saijo, Atsuro; Hanibuchi, Masaki; Goto, Hisatsugu; Toyoda, Yuko; Tezuka, Toshifumi; Nishioka, Yasuhiko

    2017-03-01

    Patients with connective tissue diseases (CTDs) are at increased risk for lung cancer (LC); interstitial lung disease (ILD) is a common form of organ dysfunction in cases of CTD. However, the influence of ILD on the treatment and prognosis in LC patients with CTD is unclear. Between January 2010 and December 2014, 27 patients among all patients with CTD at our institution were diagnosed with primary LC. We retrospectively analyzed the clinical features, treatment modalities, and outcomes of these patients, and evaluated the potential prognostic factors. Forty-four LC patients without CTD were also analyzed as a control cohort. LC patients with CTD had a significantly higher incidence of ILD as a complication compared with those without CTD (52% and 14%, respectively). CTD-associated ILD (CTD-ILD) at diagnosis was associated with significantly worse survival in LC patients with CTD. Multivariate analysis demonstrated that the complication of CTD-ILD was an independent poor prognostic factor in LC patients with CTD. The incidence of acute exacerbation (AE) of CTD-ILD was 21% among LC patients with CTD, and all of these patients died despite intensive treatment including high-dose corticosteroids. The restrictions in curative therapy for LC due to the presence of ILD and AE of CTD-ILD were thought to be the major reasons for the poor outcome. LC patients with CTD had a high prevalence of ILD, and the presence of CTD-ILD was significantly associated with poor prognosis. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  3. Validation of Tuba1a as Appropriate Internal Control for Normalization of Gene Expression Analysis during Mouse Lung Development

    Directory of Open Access Journals (Sweden)

    Aditi Mehta

    2015-02-01

    Full Text Available The expression ratio between the analysed gene and an internal control gene is the most widely used normalization method for quantitative RT-PCR (qRT-PCR expression analysis. The ideal reference gene for a specific experiment is the one whose expression is not affected by the different experimental conditions tested. In this study, we validate the applicability of five commonly used reference genes during different stages of mouse lung development. The stability of expression of five different reference genes (Tuba1a, Actb Gapdh, Rn18S and Hist4h4 was calculated within five experimental groups using the statistical algorithm of geNorm software. Overall, Tuba1a showed the least variability in expression among the different stages of lung development, while Hist4h4 and Rn18S showed the maximum variability in their expression. Expression analysis of two lung specific markers, surfactant protein C (SftpC and Clara cell-specific 10 kDA protein (Scgb1a1, normalized to each of the five reference genes tested here, confirmed our results and showed that incorrect reference gene choice can lead to artefacts. Moreover, a combination of two internal controls for normalization of expression analysis during lung development will increase the accuracy and reliability of results.

  4. Prospettive sonore nell’analisi sensoriale-acustica e nella progettazione del cibo - Sound perspectives in the sensory-acoustic analysis and design of food

    Directory of Open Access Journals (Sweden)

    Doriana Dal Palù

    2015-09-01

    Full Text Available L’articolo affronta il complesso tema della progettazione del suono del cibo, ponendo l’aspetto al centro del processo progettuale e considerandolo come un reale requisito di progetto. Sono messe in luce le potenzialità del progettare il suono, ma anche le difficoltà attuali da tenere in considerazione. Si propone l’applicazione di SounBe, una metodologia ed uno strumento brevettati che traggono origine dal mondo della psicoacustica e dell’analisi sensoriale, permettendo di confrontare attraverso una procedura standardizzata suoni di campioni di materiali o di cibi. È riportata una prima applicazione sperimentale e sono discusse le prospettive future nel mondo del cibo. ------ This paper deals with the complex theme of food sound design, focusing this issue at the core of the design process and considering it as a real project requirement. Some opportunities of sound design will be proposed, as well as some criticalities to be always considered. It will propose the application of SounBe, a patented method and tool developed drawing information from psychoacoustics and sensory analysis fields, that allows to compare by a standardized procedure the sounds produced by material samples or foodstuffs. A first experimental application of the method will be presented and, in conclusion, several future perspectives in the world of food will be discussed.

  5. Prophylactic cranial irradiation in resected small cell lung cancer: A systematic review with meta-analysis

    Science.gov (United States)

    Yang, Yang; Zhang, Danhong; Zhou, Xia; Bao, Wuan; Ji, Yonglin; Sheng, Liming; Cheng, Lei; Chen, Ying; Du, Xianghui; Qiu, Guoqin

    2018-01-01

    Background: The use of PCI in early operable patients with small cell lung cancer (SCLC) is still controversial. Therefore, we conducted a systematic review with meta-analysis to investigate the effects of PCI in resected SCLC patients. Methods: Relevant studies were identified from PubMed and EMBASE databases, the pooled hazard risks were obtained by the random-effects model. We also analyzed the brain metastasis (BM) risk in p-stage I patients without PCI. Results: Five retrospective studies were identified and a total of 1691 patients were included in our analysis, 315 of them received PCI. For all the resected patients, PCI was associated with improved overall survival (HR: 0.52, 95% CI: 0.33-0.82), and reduced brain metastasis risk (RR: 0.50, 95%CI: 0.32-0.78). However, with regard to p-stage I patients, no survival benefit was brought by PCI (HR: 0.87, 95% CI: 0.34-2.24). Moreover, the pooled analysis of 7 studies found that the 5-year brain metastasis risk was relatively low (12%, 95% CI: 8%-17%) for p-stage I patients without PCI. Conclusions: PCI might be associated with a favorable survival advantage and reduced BM risk in complete resected SCLC patients, except for p-stage I patients. PMID:29344290

  6. Systematic Analysis of Icotinib Treatment for Patients with Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Shi, Bing; Zhang, Xiu-Bing; Xu, Jian; Huang, Xin-En

    2015-01-01

    This analysis was conducted to evaluate the efficacy and safety of icotinib based regimens in treating patients with non-small cell lung cancer (NSCLC). Clinical studies evaluating the efficacy and safety of icotinib-based regimens with regard to response and safety for patients with NSCLC were identified using a predefined search strategy. Pooled response rates of treatment were calculated. With icotinib-based regimens, 7 clinical studies which including 5,985 Chinese patients with NSCLC were considered eligible for inclusion. The pooled analysis suggested that, in all patients, the positive reponse rate was 30.1% (1,803/5,985) with icotinib-based regimens. Mild skin itching, rashes and diarrhea were the main side effects. No grade III or IV renal or liver toxicity was observed. No treatment-related death occurred in patients treated with icotinib-based regimens. This evidence based analysis suggests that icotinib based regimens are associated with mild response rate and acceptable toxicity for treating Chinese patients with NSCLC.

  7. An analysis of the correlations between the turbulent flow and the sound pressure fields of subsonic jets

    OpenAIRE

    Bogey , Christophe; Bailly , Christophe

    2007-01-01

    International audience; Noise generation is investigated in subsonic isothermal round jets at Mach numbers M =0.6 and M =0.9, with Reynolds numbers ReD =1700 and ReD 105, using causality methods on data provided by large-eddy simulations. The correlations between broadband sound pressure signals and broadband turbulence signals along the jet axis and the shear layer are calculated. The normalized correlations are found to be significant between the pressure emitted in the downstream direction...

  8. Expression analysis of asthma candidate genes during human and murine lung development.

    Science.gov (United States)

    Melén, Erik; Kho, Alvin T; Sharma, Sunita; Gaedigk, Roger; Leeder, J Steven; Mariani, Thomas J; Carey, Vincent J; Weiss, Scott T; Tantisira, Kelan G

    2011-06-23

    Little is known about the role of most asthma susceptibility genes during human lung development. Genetic determinants for normal lung development are not only important early in life, but also for later lung function. To investigate the role of expression patterns of well-defined asthma susceptibility genes during human and murine lung development. We hypothesized that genes influencing normal airways development would be over-represented by genes associated with asthma. Asthma genes were first identified via comprehensive search of the current literature. Next, we analyzed their expression patterns in the developing human lung during the pseudoglandular (gestational age, 7-16 weeks) and canalicular (17-26 weeks) stages of development, and in the complete developing lung time series of 3 mouse strains: A/J, SW, C57BL6. In total, 96 genes with association to asthma in at least two human populations were identified in the literature. Overall, there was no significant over-representation of the asthma genes among genes differentially expressed during lung development, although trends were seen in the human (Odds ratio, OR 1.22, confidence interval, CI 0.90-1.62) and C57BL6 mouse (OR 1.41, CI 0.92-2.11) data. However, differential expression of some asthma genes was consistent in both developing human and murine lung, e.g. NOD1, EDN1, CCL5, RORA and HLA-G. Among the asthma genes identified in genome wide association studies, ROBO1, RORA, HLA-DQB1, IL2RB and PDE10A were differentially expressed during human lung development. Our data provide insight about the role of asthma susceptibility genes during lung development and suggest common mechanisms underlying lung morphogenesis and pathogenesis of respiratory diseases.

  9. Statistics of natural binaural sounds.

    Directory of Open Access Journals (Sweden)

    Wiktor Młynarski

    Full Text Available Binaural sound localization is usually considered a discrimination task, where interaural phase (IPD and level (ILD disparities at narrowly tuned frequency channels are utilized to identify a position of a sound source. In natural conditions however, binaural circuits are exposed to a stimulation by sound waves originating from multiple, often moving and overlapping sources. Therefore statistics of binaural cues depend on acoustic properties and the spatial configuration of the environment. Distribution of cues encountered naturally and their dependence on physical properties of an auditory scene have not been studied before. In the present work we analyzed statistics of naturally encountered binaural sounds. We performed binaural recordings of three auditory scenes with varying spatial configuration and analyzed empirical cue distributions from each scene. We have found that certain properties such as the spread of IPD distributions as well as an overall shape of ILD distributions do not vary strongly between different auditory scenes. Moreover, we found that ILD distributions vary much weaker across frequency channels and IPDs often attain much higher values, than can be predicted from head filtering properties. In order to understand the complexity of the binaural hearing task in the natural environment, sound waveforms were analyzed by performing Independent Component Analysis (ICA. Properties of learned basis functions indicate that in natural conditions soundwaves in each ear are predominantly generated by independent sources. This implies that the real-world sound localization must rely on mechanisms more complex than a mere cue extraction.

  10. Statistics of natural binaural sounds.

    Science.gov (United States)

    Młynarski, Wiktor; Jost, Jürgen

    2014-01-01

    Binaural sound localization is usually considered a discrimination task, where interaural phase (IPD) and level (ILD) disparities at narrowly tuned frequency channels are utilized to identify a position of a sound source. In natural conditions however, binaural circuits are exposed to a stimulation by sound waves originating from multiple, often moving and overlapping sources. Therefore statistics of binaural cues depend on acoustic properties and the spatial configuration of the environment. Distribution of cues encountered naturally and their dependence on physical properties of an auditory scene have not been studied before. In the present work we analyzed statistics of naturally encountered binaural sounds. We performed binaural recordings of three auditory scenes with varying spatial configuration and analyzed empirical cue distributions from each scene. We have found that certain properties such as the spread of IPD distributions as well as an overall shape of ILD distributions do not vary strongly between different auditory scenes. Moreover, we found that ILD distributions vary much weaker across frequency channels and IPDs often attain much higher values, than can be predicted from head filtering properties. In order to understand the complexity of the binaural hearing task in the natural environment, sound waveforms were analyzed by performing Independent Component Analysis (ICA). Properties of learned basis functions indicate that in natural conditions soundwaves in each ear are predominantly generated by independent sources. This implies that the real-world sound localization must rely on mechanisms more complex than a mere cue extraction.

  11. WODA Technical Guidance on Underwater Sound from Dredging.

    Science.gov (United States)

    Thomsen, Frank; Borsani, Fabrizio; Clarke, Douglas; de Jong, Christ; de Wit, Pim; Goethals, Fredrik; Holtkamp, Martine; Martin, Elena San; Spadaro, Philip; van Raalte, Gerard; Victor, George Yesu Vedha; Jensen, Anders

    2016-01-01

    The World Organization of Dredging Associations (WODA) has identified underwater sound as an environmental issue that needs further consideration. A WODA Expert Group on Underwater Sound (WEGUS) prepared a guidance paper in 2013 on dredging sound, including a summary of potential impacts on aquatic biota and advice on underwater sound monitoring procedures. The paper follows a risk-based approach and provides guidance for standardization of acoustic terminology and methods for data collection and analysis. Furthermore, the literature on dredging-related sounds and the effects of dredging sounds on marine life is surveyed and guidance on the management of dredging-related sound risks is provided.

  12. The Calibration and error analysis of Shallow water (less than 100m) Multibeam Echo-Sounding System

    Science.gov (United States)

    Lin, M.

    2016-12-01

    Multibeam echo-sounders(MBES) have been developed to gather bathymetric and acoustic data for more efficient and more exact mapping of the oceans. This gain in efficiency does not come without drawbacks. Indeed, the finer the resolution of remote sensing instruments, the harder they are to calibrate. This is the case for multibeam echo-sounding systems (MBES). We are no longer dealing with sounding lines where the bathymetry must be interpolated between them to engender consistent representations of the seafloor. We now need to match together strips (swaths) of totally ensonified seabed. As a consequence, misalignment and time lag problems emerge as artifacts in the bathymetry from adjacent or overlapping swaths, particularly when operating in shallow water. More importantly, one must still verify that bathymetric data meet the accuracy requirements. This paper aims to summarize the system integration involved with MBES and identify the various source of error pertaining to shallow water survey (100m and less). A systematic method for the calibration of shallow water MBES is proposed and presented as a set of field procedures. The procedures aim at detecting, quantifying and correcting systematic instrumental and installation errors. Hence, calibrating for variations of the speed of sound in the water column, which is natural in origin, is not addressed in this document. The data which used in calibration will reference International Hydrographic Organization(IHO) and other related standards to compare. This paper aims to set a model in the specific area which can calibrate the error due to instruments. We will construct a procedure in patch test and figure out all the possibilities may make sounding data with error then calculate the error value to compensate. In general, the problems which have to be solved is the patch test's 4 correction in the Hypack system 1.Roll 2.GPS Latency 3.Pitch 4.Yaw. Cause These 4 correction affect each others, we run each survey line

  13. Analysis of histological type and CT features on patients with haemoptysis in primary lung cancer

    International Nuclear Information System (INIS)

    Zhang Yixing; Huang Jinhuo

    2008-01-01

    Objective: To explore the CT features and histological types of haemoptysis patients with primary lung cancer. Methods: 50 haemoptysis patients (group A) with primary lung cancer confirmed by bronchoendoscopic examination or operation were analyzed. 50 cases of primary lung cancer without haemoptysis were studied as the contrast group (group B). The tumor size, shape, cavity, as well as location and pathological type were compared. Results: The proportions of adenocarcinoma and squamous cell carcinoma were 48%, 26% in Group A and 23%, 31% in Group B respectively. The occurrent rate of adenocarcinoma showed significant difference between Group A and B (P>0.05). The proportion of central lung cancer and peripheral lung cancer were 54%, 50% and 46%, 50% in Group A and B respectively. No significant difference occurred in both two types of cancer between two groups (P>0.05). The average size of cancer mass were 30±2.54 mm in Group A and 32±1.93mm in group B. The occurrence rate of lung cavity was 18% and 15% respectively in Group A and B. No significant difference existed in size and the occurrence rate of lung cancer mass between Group A and B (P>0.05). Conclusion: Haemoptysis in patients of primary lung cancer was correlated with pathology type, instead of location, size and cavities. (authors)

  14. Welding and lung cancer in a pooled analysis of case-control studies.

    Science.gov (United States)

    Kendzia, Benjamin; Behrens, Thomas; Jöckel, Karl-Heinz; Siemiatycki, Jack; Kromhout, Hans; Vermeulen, Roel; Peters, Susan; Van Gelder, Rainer; Olsson, Ann; Brüske, Irene; Wichmann, H-Erich; Stücker, Isabelle; Guida, Florence; Tardón, Adonina; Merletti, Franco; Mirabelli, Dario; Richiardi, Lorenzo; Pohlabeln, Hermann; Ahrens, Wolfgang; Landi, Maria Teresa; Caporaso, Neil; Consonni, Dario; Zaridze, David; Szeszenia-Dabrowska, Neonila; Lissowska, Jolanta; Gustavsson, Per; Marcus, Michael; Fabianova, Eleonora; 't Mannetje, Andrea; Pearce, Neil; Tse, Lap Ah; Yu, Ignatius Tak-Sun; Rudnai, Peter; Bencko, Vladimir; Janout, Vladimir; Mates, Dana; Foretova, Lenka; Forastiere, Francesco; McLaughlin, John; Demers, Paul; Bueno-de-Mesquita, Bas; Boffetta, Paolo; Schüz, Joachim; Straif, Kurt; Pesch, Beate; Brüning, Thomas

    2013-11-15

    Several epidemiologic studies have indicated an increased risk of lung cancer among welders. We used the SYNERGY project database to assess welding as a risk factor for developing lung cancer. The database includes data on 15,483 male lung cancer cases and 18,388 male controls from 16 studies in Europe, Canada, China, and New Zealand conducted between 1985 and 2010. Odds ratios and 95% confidence intervals between regular or occasional welding and lung cancer were estimated, with adjustment for smoking, age, study center, and employment in other occupations associated with lung cancer risk. Overall, 568 cases and 427 controls had ever worked as welders and had an odds ratio of developing lung cancer of 1.44 (95% confidence interval: 1.25, 1.67) with the odds ratio increasing for longer duration of welding. In never and light smokers, the odds ratio was 1.96 (95% confidence interval: 1.37, 2.79). The odds ratios were somewhat higher for squamous and small cell lung cancers than for adenocarcinoma. Another 1,994 cases and 1,930 controls had ever worked in occupations with occasional welding. Work in any of these occupations was associated with some elevation of risk, though not as much as observed in regular welders. Our findings lend further support to the hypothesis that welding is associated with an increased risk of lung cancer.

  15. Lung scintigraphy and helical computed tomography for the diagnosis of pulmonary embolism : A meta-analysis

    NARCIS (Netherlands)

    van Beek, EJR; Brouwers, Elise M J; Song, B; Bongaerts, AHH; Oudkerk, M

    To assess the diagnostic value of lung scintigraphy and helical computed tomography (hCT) in patients with suspected pulmonary embolism (PE), all English-language articles that described lung scintigraphy and hCT in patients with suspected PE were retrieved. Articles were assessed for strength of

  16. The Use of 4DCT to Reduce Lung Dose: A Dosimetric Analysis

    International Nuclear Information System (INIS)

    Khan, Fazal; Bell, Glenn; Antony, Jacob; Palmer, Matt; Balter, Peter; Bucci, Kara; Chapman, Melissa Jane

    2009-01-01

    Dosimetric studies on respiratory movement suggest several advantages toward the use of 4-dimensional computed tomography (4DCT) in radiation treatment planning. 4DCT is a method to obtain a series of CT scans each representing a different respiratory phase. The use of 4DCT has provided substantial information on tumor movement in the lung, allowing for the creation of custom planning margins explicitly including respiratory motion. These custom motion margins may result in an increase in the amount of normal lung in the field; however, it is believed less normal lung is irradiated than if generic motion margins were used. Clinical data regarding dose to normal lung by using 4DCT remain rather limited. Thus, a study presenting figures on the change in normal lung dose between planned free breathing CT and 4DCT cases would be useful to the dosimetry community. We have generated plans comparing fast spiral CT and 4DCT in regard to tumor coverage and the resulting dose to normal lung for the clinical target volume (CTV) and planning target volume (PTV) expansions used at our institution. These data were analyzed for free breathing and 4D plans of 6 lung cancer patients using intensity modulated radiation therapy (IMRT). We compared doses to normal lung tissue between free breathing and 4DCT plans.

  17. Analysis of patient-reported outcomes from the LUME-Lung 1 trial

    DEFF Research Database (Denmark)

    Novello, Silvia; Kaiser, Rolf; Mellemgaard, Anders

    2015-01-01

    INTRODUCTION: The LUME-Lung 1 trial (NCT00805194; Study 1199.13) demonstrated a significant overall survival (OS) advantage for nintedanib plus docetaxel compared with placebo plus docetaxel as second-line therapy for patients with advanced non-small cell lung cancer (NSCLC) and adenocarcinoma...

  18. An expression meta-analysis of predicted microRNA targets identifies a diagnostic signature for lung cancer

    Directory of Open Access Journals (Sweden)

    Liang Yu

    2008-12-01

    Full Text Available Abstract Background Patients diagnosed with lung adenocarcinoma (AD and squamous cell carcinoma (SCC, two major histologic subtypes of lung cancer, currently receive similar standard treatments, but resistance to adjuvant chemotherapy is prevalent. Identification of differentially expressed genes marking AD and SCC may prove to be of diagnostic value and help unravel molecular basis of their histogenesis and biologies, and deliver more effective and specific systemic therapy. Methods MiRNA target genes were predicted by union of miRanda, TargetScan, and PicTar, followed by screening for matched gene symbols in NCBI human sequences and Gene Ontology (GO terms using the PANTHER database that was also used for analyzing the significance of biological processes and pathways within each ontology term. Microarray data were extracted from Gene Expression Omnibus repository, and tumor subtype prediction by gene expression used Prediction Analysis of Microarrays. Results Computationally predicted target genes of three microRNAs, miR-34b/34c/449, that were detected in human lung, testis, and fallopian tubes but not in other normal tissues, were filtered by representation of GO terms and their ability to classify lung cancer subtypes, followed by a meta-analysis of microarray data to classify AD and SCC. Expression of a minimal set of 17 predicted miR-34b/34c/449 target genes derived from the developmental process GO category was identified from a training set to classify 41 AD and 17 SCC, and correctly predicted in average 87% of 354 AD and 82% of 282 SCC specimens from total 9 independent published datasets. The accuracy of prediction still remains comparable when classifying 103 AD and 79 SCC samples from another 4 published datasets that have only 14 to 16 of the 17 genes available for prediction (84% and 85% for AD and SCC, respectively. Expression of this signature in two published datasets of epithelial cells obtained at bronchoscopy from cigarette

  19. Combined human papillomavirus typing and TP53 mutation analysis in distinguishing second primary tumors from lung metastases in patients with head and neck squamous cell carcinoma.

    Science.gov (United States)

    Daher, Tamas; Tur, Mehmet Kemal; Brobeil, Alexander; Etschmann, Benjamin; Witte, Biruta; Engenhart-Cabillic, Rita; Krombach, Gabriele; Blau, Wolfgang; Grimminger, Friedrich; Seeger, Werner; Klussmann, Jens Peter; Bräuninger, Andreas; Gattenlöhner, Stefan

    2018-06-01

    In head and neck squamous cell carcinoma (HNSCC), the occurrence of concurrent lung malignancies poses a significant diagnostic challenge because metastatic HNSCC is difficult to discern from second primary lung squamous cell carcinoma (SCC). However, this differentiation is crucial because the recommended treatments for metastatic HNSCC and second primary lung SCC differ profoundly. We analyzed the origin of lung tumors in 32 patients with HNSCC using human papillomavirus (HPV) typing and targeted next generation sequencing of all coding exons of tumor protein 53 (TP53). Lung tumors were clearly identified as HNSCC metastases or second primary tumors in 29 patients, thus revealing that 16 patients had received incorrect diagnoses based on clinical and morphological data alone. The HPV typing and mutation analysis of all TP53 coding exons is a valuable diagnostic tool in patients with HNSCC and concurrent lung SCC, which can help to ensure that patients receive the most suitable treatment. © 2018 Wiley Periodicals, Inc.

  20. Robotic Versus Video-assisted Lobectomy/Segmentectomy for Lung Cancer: A Meta-analysis.

    Science.gov (United States)

    Liang, Hengrui; Liang, Wenhua; Zhao, Lei; Chen, Difei; Zhang, Jianrong; Zhang, Yiyin; Tang, Shiyan; He, Jianxing

    2017-06-16

    : Objective: To compare the safety/efficacy of the robotic-assisted lobectomy/segmentectomy (RAL/S) with the video-assisted lobectomy/segmentectomy (VAL/S) for radical lung cancer resection. It remains uncertain whether the newly developed RAL/S is comparable with the VAL/S. A comprehensive search of online databases was performed. Perioperative outcomes were synthesized. Cumulative meta-analysis was performed to evaluate the temporal trend of pooled outcomes. Specific subgroups (propensity score matching studies, pure lobectomy studies) were examined. Analysis of 14 studies including a total of 7438 patients was performed. RAL/S was performed on 3239 patients, whereas the other 4199 patients underwent VAL/S. The 30-day mortality [0.7% vs 1.1%; odds ratio (OR) 0.53, P = 0.045] and conversion rate to open surgery (10.3% vs 11.9%; OR 0.57, P < 0.001) were significantly lower in patients who underwent RAL/S than VAL/S. Meanwhile, the postoperative complications (27.5% vs 28.2%; OR 0.95, P = 0.431), operation time [176.63 vs 162.74 min; standardized mean difference (SMD) 0.30, P = 0.086], duration of hospitalization (4.90 vs 5.23 days; SMD -0.08, P = 0.292), days to tube removal (4.10 vs 3.53 days; SMD 0.25, P = 0.120), retrieved lymph node (11.96 vs 10.67; SMD 0.46, P = 0.381), and retrieved lymph node station (4.98 vs 4.32; SMD 0.83, P = 0.261) were similar between the 2 groups. The cumulative meta-analyses suggested that the relative effects between 2 groups have already stabilized. All outcomes of subgroup and overall analyses were similar. This up-to-date meta-analysis confirms that RAL/S is a feasible and safe alternative to VAL/S for radical resection of lung cancer. Future studies should focus on the long-term benefits and cost effectiveness of RAL/S compared with VAL/S.

  1. Histogram analysis for age change of human lung with computed tomography

    International Nuclear Information System (INIS)

    Shirabe, Ichiju

    1990-01-01

    In order to evaluate physiological changes of normal lung with aging by computed tomography (CT), the peak position (PP) and full width half maximum (FWHM) of CT-histogram were studied in 77 normal human lung. Above 30 years old, PP tended to be seen in the lower attenuation value with advancing ages, with the result that the follow equation was obtained. CT attenuation value of PP=-0.87 x age -815. The peak position shifted to the range of higher CT attenuation in 30's. FWHM did not change with advancing ages. There were no differences of peak value and FWHM among the upper, middle and lower lung field. In this study, physiological changes of lung were evaluated quantitatively. Furthermore, this study was considered to be useful for diagnosis and treatment in lung diseases. (author)

  2. Risk of lung cancer and consumption of vegetables and fruit in Japanese: A pooled analysis of cohort studies in Japan

    Science.gov (United States)

    Wakai, Kenji; Sugawara, Yumi; Tsuji, Ichiro; Tamakoshi, Akiko; Shimazu, Taichi; Matsuo, Keitaro; Nagata, Chisato; Mizoue, Tetsuya; Tanaka, Keitaro; Inoue, Manami; Tsugane, Shoichiro; Sasazuki, Shizuka

    2015-01-01

    International reviews have concluded that consumption of fruit and vegetables might decrease the risk of lung cancer. However, the relevant epidemiological evidence still remains insufficient in Japan. Therefore, we performed a pooled analysis of data from four population-based cohort studies in Japan with >200 000 participants and >1700 lung cancer cases. We computed study-specific hazard ratios by quintiles of vegetable and fruit consumption as assessed by food frequency questionnaires. Summary hazard ratios were estimated by pooling the study-specific hazard ratios with a fixed-effect model. In men, we found inverse associations between fruit consumption and the age-adjusted and area-adjusted risk of mortality or incidence of lung cancer. However, the associations were largely attenuated after adjustment for smoking and energy intake. The significant decrease in risk among men remained only for a moderate level of fruit consumption; the lowest summary hazard ratios were found in the third quintile of intake (mortality: 0.71, 95% confidence interval 0.60–0.84; incidence: 0.83, 95% confidence interval 0.70–0.98). This decrease in risk was mainly detected in ever smokers. Conversely, vegetable intake was positively correlated with the risk of incidence of lung cancer after adjustment for smoking and energy intake in men (trend P, 0.024); the summary hazard ratio for the highest quintile was 1.26 (95% confidence interval 1.05–1.50). However, a similar association was not detected for mortality from lung cancer. In conclusion, a moderate level of fruit consumption is associated with a decreased risk of lung cancer in men among the Japanese population. PMID:26033436

  3. Gene expression analysis in rat lungs after intratracheal exposure to nanoparticles doped with cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Coccini, Teresa; Manzo, Luigi [Toxicology Division, Salvatore Maugeri Foundation IRCCS, Pavia (Italy); Fabbri, Marco; Sacco, Maria Grazia; Gribaldo, Laura [European Commission, Joint Research Centre, IHCP- 21027 Ispra (Italy); Roda, Elisa [European Centre for Nanomedicine, University of Pavia, 27100 Pavia (Italy)

    2011-07-06

    Silica nanoparticles (NPs) incorporating cadmium (Cd) have been developed for a range of potential application including drug delivery devices. Occupational Cd inhalation has been associated with emphysema, pulmonary fibrosis and lung tumours. Mechanistically, Cd can induce oxidative stress and mediate cell-signalling pathways that are involved in inflammation.This in vivo study aimed at investigating pulmonary molecular effects of NPs doped with Cd (NP-Cd, 1 mg/animal) compared to soluble CdCl{sub 2} (400 {mu}g/animal), in Sprague Dawley rats treated intra-tracheally, 7 and 30 days after administration. NPs of silica containing Cd salt were prepared starting from commercial nano-size silica powder (HiSil{sup TM} T700 Degussa) with average pore size of 20 nm and surface area of 240 m{sup 2}/g. Toxicogenomic analysis was performed by the DNA microarray technology (using Agilent Whole Rat Genome Microarray 4x44K) to evaluate changes in gene expression of the entire genome. These findings indicate that the whole genome analysis may represent a valuable approach to assess the whole spectrum of biological responses to cadmium containing nanomaterials.

  4. Quantitative Analysis of Cellular Proteome Alterations in CDV-Infected Mink Lung Epithelial Cells

    Directory of Open Access Journals (Sweden)

    Mingwei Tong

    2017-12-01

    Full Text Available Canine distemper virus (CDV, a paramyxovirus, causes a severe highly contagious lethal disease in carnivores, such as mink. Mink lung epithelial cells (Mv.1.Lu cells are sensitive to CDV infection and are homologous to the natural host system of mink. The current study analyzed the response of Mv.1.Lu cells to CDV infection by iTRAQ combined with LC–MS/MS. In total, 151 and 369 differentially expressed proteins (DEPs were markedly up-regulated or down-regulated, respectively. Thirteen DEPs were validated via real-time RT-PCR or western blot analysis. Network and KEGG pathway analyses revealed several regulated proteins associated with the NF-κB signaling pathway. Further validation was performed by western blot analysis and immunofluorescence assay, which demonstrated that different CDV strains induced NF-κB P65 phosphorylation and nuclear translocation. Moreover, the results provided interesting information that some identified DEPs possibly associated with the pathogenesis and the immune response upon CDV infection. This study is the first overview of the responses to CDV infection in Mv.1.Lu cells, and the findings will help to analyze further aspects of the molecular mechanisms involved in viral pathogenesis and the immune responses upon CDV infection.

  5. Gefitinib versus docetaxel in treated non-small-cell lung cancer: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Wang Bing

    2017-06-01

    Full Text Available The objective of this study was to perform a meta-analysis to evaluate the efficacy and toxicity of gefitinib and docetaxel in treated patients with non-small-cell lung cancer (NSCLC. Methods. A literature search was performed using PubMed and CNKI databases for relevant keywords and the Medical Subject Headings. After further full-text screening, 10 clinical trials were included in the final meta-analysis. Specific odds ratios (OR and confidence intervals were calculated. Results. The outcomes of treatment efficacy included disease control rates, quality-of-life improvement rates, 3~4 grade adverse events. Comparing gefitinib to docetaxel for NSCLC patients, the pooled odds ratios (OR of disease control rates was 1.09, (95% confidential index [CI] = 0.84–1.43, the pooled OR of quality-of-life improvement rates was 2.49, (95% CI = 1.77–3.49, the pooled OR of 3~4 grade adverse events was 0.49, (95% CI = 0.32–0.75. Conclusion. Gefitinib was found to significantly improve patients’ quality-of-life and obviously decrease patients’ adverse events of 3~4 grade.There is no difference of disease control rates between gefitinib and docetaxel.

  6. Gene expression analysis in rat lungs after intratracheal exposure to nanoparticles doped with cadmium

    International Nuclear Information System (INIS)

    Coccini, Teresa; Manzo, Luigi; Fabbri, Marco; Sacco, Maria Grazia; Gribaldo, Laura; Roda, Elisa

    2011-01-01

    Silica nanoparticles (NPs) incorporating cadmium (Cd) have been developed for a range of potential application including drug delivery devices. Occupational Cd inhalation has been associated with emphysema, pulmonary fibrosis and lung tumours. Mechanistically, Cd can induce oxidative stress and mediate cell-signalling pathways that are involved in inflammation.This in vivo study aimed at investigating pulmonary molecular effects of NPs doped with Cd (NP-Cd, 1 mg/animal) compared to soluble CdCl 2 (400 μg/animal), in Sprague Dawley rats treated intra-tracheally, 7 and 30 days after administration. NPs of silica containing Cd salt were prepared starting from commercial nano-size silica powder (HiSil T M T700 Degussa) with average pore size of 20 nm and surface area of 240 m 2 /g. Toxicogenomic analysis was performed by the DNA microarray technology (using Agilent Whole Rat Genome Microarray 4x44K) to evaluate changes in gene expression of the entire genome. These findings indicate that the whole genome analysis may represent a valuable approach to assess the whole spectrum of biological responses to cadmium containing nanomaterials.

  7. Gene expression analysis in rat lungs after intratracheal exposure to nanoparticles doped with cadmium

    Science.gov (United States)

    Coccini, Teresa; Fabbri, Marco; Roda, Elisa; Grazia Sacco, Maria; Manzo, Luigi; Gribaldo, Laura

    2011-07-01

    Silica nanoparticles (NPs) incorporating cadmium (Cd) have been developed for a range of potential application including drug delivery devices. Occupational Cd inhalation has been associated with emphysema, pulmonary fibrosis and lung tumours. Mechanistically, Cd can induce oxidative stress and mediate cell-signalling pathways that are involved in inflammation.This in vivo study aimed at investigating pulmonary molecular effects of NPs doped with Cd (NP-Cd, 1 mg/animal) compared to soluble CdCl2 (400 μg/animal), in Sprague Dawley rats treated intra-tracheally, 7 and 30 days after administration. NPs of silica containing Cd salt were prepared starting from commercial nano-size silica powder (HiSil™ T700 Degussa) with average pore size of 20 nm and surface area of 240 m2/g. Toxicogenomic analysis was performed by the DNA microarray technology (using Agilent Whole Rat Genome Microarray 4×44K) to evaluate changes in gene expression of the entire genome. These findings indicate that the whole genome analysis may represent a valuable approach to assess the whole spectrum of biological responses to cadmium containing nanomaterials.

  8. Comparative synchronous fluorescence spectrophotometry and 32P-postlabeling analysis of PAH-DNA adducts in human lung and the relationship to TP53 mutations

    DEFF Research Database (Denmark)

    Andreassen, Åshild; Kure, Elin H.; Nielsen, Per Sabro

    1996-01-01

    Polycyclic aromatic hydrocarbon (PAH)-DNA adducts were studied in human lung from 39 lung cancer patients by synchronous fluorescence spectrophotometric (SFS) and 32P-postlabeling assays. Regression analysis of the samples failed to detect any correlation between benzo[a]pyrene-diolepoxide (BPDE)...

  9. True microbiota involved in chronic lung infection of cystic fibrosis patients found by culturing and 16S rRNA gene analysis

    DEFF Research Database (Denmark)

    Rudkjøbing, Vibeke Børsholt; Thomsen, Trine R; Alhede, Morten

    2011-01-01

    Patients suffering from cystic fibrosis (CF) develop chronic lung infection. In this study, we investigated the microorganisms present in transplanted CF lungs (n = 5) by standard culturing and 16S rRNA gene analysis. A correspondence between culturing and the molecular methods was observed. In c...

  10. Cost-effectiveness analysis of paclitaxel + carboplatin vs. alternative combinations in the treatment of non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Mario Eandi

    2006-06-01

    Full Text Available Non-small cell lung cancer (NSCLC is the most common type of lung cancer and its medical and economical burden represents a serious matter in Europe and Usa, due to its high mortality rates and drug costs. Lung cancer is responsible for about 30% of cancer death in men and women; in Europe only about 8 per cent of people with lung cancer survive for 5 years. At present combination chemotherapy based on cisplatin or carboplatin associated with paclitaxel, vinorelbine or gemcitabine is the state of the art for the treatment in patients with stage IIIb or IV NSCLC. Aim of this study was to compare the cost-effectiveness of paclitaxel/carboplatin (PCb, gemcitabine/cisplatin (GC and vinorelbine/cisplatin (VC in the perspective of the Italian National Health Service. Therefore we perfomed a semi-Markov decision model mainly based on clinical results from the Italian Lung Cancer Project. The model included differential direct medical costs registered for two years from starting chemotherapy, using tariffs valid for 2005. Benefits was measured by years of life saved (YOLs. The model also allowed to estimate only costs accrued over the period of time, performing a cost-minimisation analysis. According to cost-effectiveness analysis, VC is dominated because it’s more costly and less effective than GC. On the contrary, combination chemotherapy with GC is more inexpensive but less effective than paclitaxel/carboplatin (PCb: in this case we compared the incremental cost-effectiveness ratio (ICER with a maximum acceptable willingness-to-pay (WTP value. In the base scenario the ICER of PCb over GC treatment is 52,326 euro/ YOLs, which is definitely lower than the maximum acceptable WTP value. Sensitivity analyses confirmed the robustness of the results from cost-effectiveness analysis in the base scenario.

  11. Meteorological and other data from moored buoys in Prince William Sound (Gulf of Alaska) in support of the Sound Ecosystem Analysis (SEAS) project from 08 October 1991 to 16 December 1998 (NODC Accession 0000482)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Meteorological and other data were collected from Prince William Sound (Gulf of Alaska) from moored buoys from 08 October 1991 to 16 December 1998. Buoys are part of...

  12. Meteorological Satellites (METSAT) and Earth Observing System (EOS) Advanced Microwave Sounding Unit-A (AMSU-A) Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL)

    Science.gov (United States)

    1996-01-01

    This Failure Modes and Effects Analysis (FMEA) is for the Advanced Microwave Sounding Unit-A (AMSU-A) instruments that are being designed and manufactured for the Meteorological Satellites Project (METSAT) and the Earth Observing System (EOS) integrated programs. The FMEA analyzes the design of the METSAT and EOS instruments as they currently exist. This FMEA is intended to identify METSAT and EOS failure modes and their effect on spacecraft-instrument and instrument-component interfaces. The prime objective of this FMEA is to identify potential catastrophic and critical failures so that susceptibility to the failures and their effects can be eliminated from the METSAT/EOS instruments.

  13. Sound wave transmission (image)

    Science.gov (United States)

    When sounds waves reach the ear, they are translated into nerve impulses. These impulses then travel to the brain where they are interpreted by the brain as sound. The hearing mechanisms within the inner ear, can ...

  14. Principles of underwater sound

    National Research Council Canada - National Science Library

    Urick, Robert J

    1983-01-01

    ... the immediately useful help they need for sonar problem solving. Its coverage is broad-ranging from the basic concepts of sound in the sea to making performance predictions in such applications as depth sounding, fish finding, and submarine detection...

  15. Individual difficulties and resources – a qualitative analysis in patients with advanced lung cancer and their relatives

    Directory of Open Access Journals (Sweden)

    Sparla A

    2016-10-01

    Full Text Available Anika Sparla,1 Sebastian Flach-Vorgang,1 Matthias Villalobos,2 Katja Krug,1 Martina Kamradt,1 Kadiatou Coulibaly,1 Joachim Szecsenyi,1 Michael Thomas,2 Sinikka Gusset-Bährer,2 Dominik Ose1,3 1Department of General Practice and Health Services Research, Heidelberg University Hospital, 2Internistische Onkologie der Thoraxtumoren, Thoraxklinik im Universitätsklinikum Heidelberg, Translational Lung Research Center Heidelberg (TLRC-H, Member of the German Center for Lung Research, Heidelberg, Germany; 3University of Utah, Department of Population Health Sciences, Health System Innovation and Research, Salt Lake City, UT, USA Purpose: Lung cancer is a disease with a high percentage of patients diagnosed in an advanced stage. In a situation of palliative treatment, both patients and their relatives experience diverse types of distress and burden. Little research has been done to identify the individual difficulties and resources for patients with advanced lung cancer and their relatives. Especially, standardized questionnaire-based exploration may not assess the specific distressing issues that pertain to each individual on a personal level. The purpose of this qualitative study is to explore and compare individual difficulties and resources for lung cancer patients and their relatives within the palliative care context.Methods: Data were collected by qualitative interviews. A total of 18 participants, nine patients diagnosed with advanced lung cancer (International Classification of Diseases, tenth edition, diagnosis C-34, stage IV starting or receiving palliative treatment and nine relatives, were interviewed. Data were interpreted through qualitative content analysis.Results: We identified four main categories of difficulties: communication and conflicts, home and everyday life, thinking about cancer, and treatment trajectory. In general, difficulties were related to interpersonal relationships as well as to impact of chemotherapy. Family

  16. An analysis of post-vocalic /s-ʃ/ neutralization in Augsburg German: evidence for a gradient sound change

    Directory of Open Access Journals (Sweden)

    Véronique eBukmaier

    2014-07-01

    Full Text Available The study is concerned with a sound change in progress by which a post-vocalic, pre-consonantal /s-ʃ/ contrast in the standard variety of German (SG in words such as west/wäscht (/vɛst/~/vɛʃt/, west/washes is influencing the Augsburg German (AG variety in which they have been hitherto neutralized as /veʃt/. Two of the main issues to be considered are whether the change is necessarily categorical; and the extent to which the change affects both speech production and perception equally. For the production experiment, younger and older AG and SG speakers merged syllables of hypothetical town names to create a blend at the potential neutralization site. These results showed a trend for a progressively greater /s-ʃ/ differentiation in the order older AG, younger AG, and SG speakers. For the perception experiment, forced-choice responses were obtained from the same subjects who had participated in the production experiment to a 16-step /s-ʃ/ continuum that was embedded into two contexts: /mɪst-mɪʃt/ in which /s-ʃ/ are neutralized in AG and /vəˈmɪsə/-/vəˈmɪʃə/ in which they are not. The results from both experiments are indicative of a sound change in progress such that the neutralization is being undone under the influence of SG, but in such a way that there is a gradual shift between categories. The closer approximation of the groups on perception suggests that the sound change may be more advanced on this modality than in production. Overall, the findings are consistent with the idea that phonological contrasts are experience-based, i.e. a continuous function of the extent to which a subject is exposed to, and makes use of, the distinction and are thus compatible with exemplar models of speech.

  17. An analysis of ground shaking and transmission loss from infra sound generated by the 2011 Tohoku earthquake

    International Nuclear Information System (INIS)

    Walker, Kristoffer T.; Le Pichon, Alexis; Tae Sung Kim; Il-Young Che; Groot-Hedlin, Catherine de; Garces, Milton

    2013-01-01

    The 2011 Mw 9.0 Tohoku earthquake generated infra sound that was recorded by nine infrasonic arrays. Most arrays recorded a back azimuth variation with time due to the expanse of the source region. We use ray tracing to predict group velocities and back azimuth wind corrections. A Japan accelerometer network recorded ground shaking in unprecedented spatial resolution. We back projected infra sound from arrays IS44 (Kamchatka) and IS30 (Tokyo) to the source region and compare these results with acceleration data. IS44 illuminates the complex geometry of land areas that experienced shaking. IS30 illuminates two volcanoes and a flat area around the city of Sendai, where the maximum accelerations occurred. The arrays and epicentral region define three source-receiver profiles. The observed broadband energy transmission loss (TL) follows an exponential decay law. The best fitting model, which has parameters that are interpreted to include the effects of geometric spreading, scattering, and the maximum ratio of the effective sound speed in the stratosphere to that at the ground (accounts for stratospheric wind speed), yields a 65% variance reduction relative to predictions from a traditional TL relationship. This model is a simplified version of the model of Le Pichon et al. (2012), which yields an 83% variance reduction for a single frequency, implying that fine-scale atmospheric structure is required to explain the TL for stratospheric upwind propagation. Our results show that infrasonic arrays are sensitive to ground acceleration in the source region of mega-thrust earthquakes. The TL results may improve infrasonic amplitude scaling laws for explosive yield. (authors)

  18. H-1 Nuclear Magnetic Resonance Metabolomics Analysis Identifies Novel Urinary Biomarkers for Lung Function

    International Nuclear Information System (INIS)

    McClay, Joseph L.; Adkins, Daniel E.; Isern, Nancy G.; O'Connell, Thomas M.; Wooten, Jan B.; Zedler, Barbara K.; Dasika, Madhukar S.; Webb, B.T.; Webb-Robertson, Bobbie-Jo M.; Pounds, Joel G.; Murrelle, Edward L.; Leppert, Mark F.; van den Oord, Edwin J.

    2010-01-01

    Chronic obstructive pulmonary disease (COPD), characterized by chronic airflow limitation, is a serious and growing public health concern. The major environmental risk factor for COPD is tobacco smoking, but the biological mechanisms underlying COPD are not well understood. In this study, we used proton nuclear magnetic resonance (1H-NMR) spectroscopy to identify and quantify metabolites associated with lung function in COPD. Plasma and urine were collected from 197 adults with COPD and from 195 adults without COPD. Samples were assayed using a 600 MHz NMR spectrometer, and the resulting spectra were analyzed against quantitative spirometric measures of lung function. After correcting for false discoveries and adjusting for covariates (sex, age, smoking) several spectral regions in urine were found to be significantly associated with baseline lung function. These regions correspond to the metabolites trigonelline, hippurate and formate. Concentrations of each metabolite, standardized to urinary creatinine, were associated with baseline lung function (minimum p-value = 0.0002 for trigonelline). No significant associations were found with plasma metabolites. Two of the three urinary metabolites positively associated with baseline lung function, i.e. hippurate and formate, are often related to gut microflora. This suggests that the microbiome composition is variable between individuals with different lung function. Alternatively, the nature and origins of all three associated metabolites may reflect lifestyle differences affecting overall health. Our results will require replication and validation, but demonstrate the utility of NMR metabolomics as a screening tool for identifying novel biomarkers of lung disease or disease risk.

  19. Detection and Severity Scoring of Chronic Obstructive Pulmonary Disease Using Volumetric Analysis of Lung CT Images

    International Nuclear Information System (INIS)

    Hosseini, Mohammad Parsa; Soltanian-Zadeh, Hamid; Akhlaghpoor, Shahram

    2012-01-01

    Chronic obstructive pulmonary disease (COPD) is a devastating disease.While there is no cure for COPD and the lung damage associated with this disease cannot be reversed, it is still very important to diagnose it as early as possible. In this paper, we propose a novel method based on the measurement of air trapping in the lungs from CT images to detect COPD and to evaluate its severity. Twenty-five patients and twelve normal adults were included in this study. The proposed method found volumetric changes of the lungs from inspiration to expiration. To this end, trachea CT images at full inspiration and expiration were compared and changes in the areas and volumes of the lungs between inspiration and expiration were used to define quantitative measures (features). Using these features,the subjects were classified into two groups of normal and COPD patients using a Bayesian classifier. In addition, t-tests were applied to evaluate discrimination powers of the features for this classification. For the cases studied, the proposed method estimated air trapping in the lungs from CT images without human intervention. Based on the results, a mathematical model was developed to relate variations of lung volumes to the severity of the disease. As a computer aided diagnosis (CAD) system, the proposed method may assist radiologists in the detection of COPD. It quantifies air trapping in the lungs and thus may assist them with the scoring of the disease by quantifying the severity of the disease

  20. An Antropologist of Sound

    DEFF Research Database (Denmark)

    Groth, Sanne Krogh

    2015-01-01

    PROFESSOR PORTRAIT: Sanne Krogh Groth met Holger Schulze, newly appointed professor in Musicology at the Department for Arts and Cultural Studies, University of Copenhagen, to a talk about anthropology of sound, sound studies, musical canons and ideology.......PROFESSOR PORTRAIT: Sanne Krogh Groth met Holger Schulze, newly appointed professor in Musicology at the Department for Arts and Cultural Studies, University of Copenhagen, to a talk about anthropology of sound, sound studies, musical canons and ideology....

  1. Broadcast sound technology

    CERN Document Server

    Talbot-Smith, Michael

    1990-01-01

    Broadcast Sound Technology provides an explanation of the underlying principles of modern audio technology. Organized into 21 chapters, the book first describes the basic sound; behavior of sound waves; aspects of hearing, harming, and charming the ear; room acoustics; reverberation; microphones; phantom power; loudspeakers; basic stereo; and monitoring of audio signal. Subsequent chapters explore the processing of audio signal, sockets, sound desks, and digital audio. Analogue and digital tape recording and reproduction, as well as noise reduction, are also explained.

  2. Propagation of sound

    DEFF Research Database (Denmark)

    Wahlberg, Magnus; Larsen, Ole Næsbye

    2017-01-01

    properties can be modified by sound absorption, refraction, and interference from multi paths caused by reflections.The path from the source to the receiver may be bent due to refraction. Besides geometrical attenuation, the ground effect and turbulence are the most important mechanisms to influence...... communication sounds for airborne acoustics and bottom and surface effects for underwater sounds. Refraction becomes very important close to shadow zones. For echolocation signals, geometric attenuation and sound absorption have the largest effects on the signals....

  3. Abnormal sound detection device

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji.

    1995-01-01

    Only components synchronized with rotation of pumps are sampled from detected acoustic sounds, to judge the presence or absence of abnormality based on the magnitude of the synchronized components. A synchronized component sampling means can remove resonance sounds and other acoustic sounds generated at a synchronously with the rotation based on the knowledge that generated acoustic components in a normal state are a sort of resonance sounds and are not precisely synchronized with the number of rotation. On the other hand, abnormal sounds of a rotating body are often caused by compulsory force accompanying the rotation as a generation source, and the abnormal sounds can be detected by extracting only the rotation-synchronized components. Since components of normal acoustic sounds generated at present are discriminated from the detected sounds, reduction of the abnormal sounds due to a signal processing can be avoided and, as a result, abnormal sound detection sensitivity can be improved. Further, since it is adapted to discriminate the occurrence of the abnormal sound from the actually detected sounds, the other frequency components which are forecast but not generated actually are not removed, so that it is further effective for the improvement of detection sensitivity. (N.H.)

  4. Modelling Hyperboloid Sound Scattering

    DEFF Research Database (Denmark)

    Burry, Jane; Davis, Daniel; Peters, Brady

    2011-01-01

    The Responsive Acoustic Surfaces workshop project described here sought new understandings about the interaction between geometry and sound in the arena of sound scattering. This paper reports on the challenges associated with modelling, simulating, fabricating and measuring this phenomenon using...... both physical and digital models at three distinct scales. The results suggest hyperboloid geometry, while difficult to fabricate, facilitates sound scattering....

  5. Secondhand smoke exposure and risk of lung cancer in Japan: a systematic review and meta-analysis of epidemiologic studies.

    Science.gov (United States)

    Hori, Megumi; Tanaka, Hirokazu; Wakai, Kenji; Sasazuki, Shizuka; Katanoda, Kota

    2016-10-01

    Systematic evaluation of the association between secondhand smoke exposure and lung cancer in Japan has yet to be conducted. Here, we performed a systematic review and meta-analysis of the relationship between secondhand smoke and lung cancer in Japanese non-smokers. Relevant studies were collected from the MEDLINE and Ichushi Web databases using a combination of search terms and Medical Subject Headings. Eligible studies were identified, and relative risks or odds ratios were extracted to calculate pooled risk estimates. This procedure was performed independently by at least two authors. Stratified analyses were carried out according to study design, publication year, and whether or not potential confounding variables were accounted for. The presence of publication bias was assessed via funnel plots. We identified four cohort studies and five case-control studies. Quantitative synthesis was conducted only for secondhand smoke exposure in the home during adulthood. Of the 12 populations included in meta-analysis, positive secondhand smoke exposure-lung cancer associations were observed in 11, whereas an inverse association was found in the remaining 1. The pooled relative risk of lung cancer associated with secondhand smoke exposure was 1.28 (95% confidence interval: 1.10-1.48). We found no evidence of publication bias, and a significant association remained even when potentially missing studies were included (pooled relative risk: 1.26; 95% confidence interval: 1.09-1.46). The results were stable across different subgroup analyses, including by study design, publication year, and when adjusting for confounding variables. Secondhand smoke exposure in the home during adulthood results in a statistically significant increase in the risk of lung cancer. © The Author 2016. Published by Oxford University Press.

  6. The Relationship between FHIT Gene Promoter Methylation and Lung Cancer Risk: 
a Meta-analysis

    Directory of Open Access Journals (Sweden)

    Yichang SUN

    2014-03-01

    Full Text Available Background and objective Tumor-suppressor gene promoter DNA methylation in tumor cells is associated with its reduced expression. FHIT (fragile histindine triad was one of the important tumor suppressor genes which was found hypermethylated in the promoter region in most of tumors. The aim of this study is to evaluate the relationship between FIHT gene promother methylation and lung cancer risk by meta-analysis. Methods By searching Pubmed, CNKI and Wanfang, the open published articles related to FHIT gene promoter methylation and lung carcinoma risk were collected. The odds ratio (OR and range of FHIT gene of cancer tissue of lung cancer patients compared with normal lung tissue, plasma and the bronchial lavage fluid were pooled by statistical software Stata 11.0. Results Eleven studies were finally included in this meta-analysis. The median methylation rate were Pmedian=40.0% (0-68.3%, Pmedian=8.7% (0-35.0%, Pmedian=33.3% (17.1%-38.3% and Pmedian=35.9% (31.1%-50.8% in cancer tissue, NLT, BALF and plasm respectively. The pooled results showed the methylation rate in tumor tissue was much higer than that of NLT OR=5.82 (95%CI: 3.74-9.06, P0.05 and plasma OR=1.41 (95%CI: 0.90-2.20, P>0.05. Conclusion Hypermethylation of FHIT gene promoter region was found more frequent in cancer tissue than that of NLT which may demonstrated association between lung cancer risk and FHIT gene promoter methylation.

  7. Early Assessment of Treatment Responses During Radiation Therapy for Lung Cancer Using Quantitative Analysis of Daily Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jijo; Yang, Cungeng [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Wu, Hui [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); The Affiliated Cancer Hospital of Zhengzhou University, Zhengzhou (China); Tai, An [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Dalah, Entesar [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Department of Medical Diagnostic Imaging, College of Health Science, University of Sharjah (United Arab Emirates); Zheng, Cheng [Biostatistics, Joseph. J. Zilber School of Public Health, University of Wisconsin-Milwaukee, Milwaukee, Wisconsin (United States); Johnstone, Candice [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Kong, Feng-Ming [Department of Radiation Oncology, Indiana University, Indianapolis, Indiana (United States); Gore, Elizabeth [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Li, X. Allen, E-mail: ali@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States)

    2017-06-01

    Purpose: To investigate early tumor and normal tissue responses during the course of radiation therapy (RT) for lung cancer using quantitative analysis of daily computed tomography (CT) scans. Methods and Materials: Daily diagnostic-quality CT scans acquired using CT-on-rails during CT-guided RT for 20 lung cancer patients were quantitatively analyzed. On each daily CT set, the contours of the gross tumor volume (GTV) and lungs were generated and the radiation dose delivered was reconstructed. The changes in CT image intensity (Hounsfield unit [HU]) features in the GTV and the multiple normal lung tissue shells around the GTV were extracted from the daily CT scans. The associations between the changes in the mean HUs, GTV, accumulated dose during RT delivery, and patient survival rate were analyzed. Results: During the RT course, radiation can induce substantial changes in the HU histogram features on the daily CT scans, with reductions in the GTV mean HUs (dH) observed in the range of 11 to 48 HU (median 30). The dH is statistically related to the accumulated GTV dose (R{sup 2} > 0.99) and correlates weakly with the change in GTV (R{sup 2} = 0.3481). Statistically significant increases in patient survival rates (P=.038) were observed for patients with a higher dH in the GTV. In the normal lung, the 4 regions proximal to the GTV showed statistically significant (P<.001) HU reductions from the first to last fraction. Conclusion: Quantitative analysis of the daily CT scans indicated that the mean HUs in lung tumor and surrounding normal tissue were reduced during RT delivery. This reduction was observed in the early phase of the treatment, is patient specific, and correlated with the delivered dose. A larger HU reduction in the GTV correlated significantly with greater patient survival. The changes in daily CT features, such as the mean HU, can be used for early assessment of the radiation response during RT delivery for lung cancer.

  8. Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition

    International Nuclear Information System (INIS)

    Jacob, Richard E; Carson, James P

    2014-01-01

    Assessing heterogeneity in lung images can be an important diagnosis tool. We present a novel and objective method for assessing lung damage in a rat model of emphysema. We combined a three-dimensional (3D) computer graphics method–octree decomposition–with a geostatistics-based approach for assessing spatial relationships–the variogram–to evaluate disease in 3D computed tomography (CT) image volumes. Male, Sprague-Dawley rats were dosed intratracheally with saline (control), or with elastase dissolved in saline to either the whole lung (for mild, global disease) or a single lobe (for severe, local disease). Gated 3D micro-CT images were acquired on the lungs of all rats at end expiration. Images were masked, and octree decomposition was performed on the images to reduce the lungs to homogeneous blocks of 2 × 2 × 2, 4 × 4 × 4, and 8 × 8 × 8 voxels. To focus on lung parenchyma, small blocks were ignored because they primarily defined boundaries and vascular features, and the spatial variance between all pairs of the 8 × 8 × 8 blocks was calculated as the square of the difference of signal intensity. Variograms–graphs of distance vs. variance–were constructed, and results of a least-squares-fit were compared. The robustness of the approach was tested on images prepared with various filtering protocols. Statistical assessment of the similarity of the three control rats was made with a Kruskal-Wallis rank sum test. A Mann-Whitney-Wilcoxon rank sum test was used to measure statistical distinction between individuals. For comparison with the variogram results, the coefficient of variation and the emphysema index were also calculated for all rats. Variogram analysis showed that the control rats were statistically indistinct (p = 0.12), but there were significant differences between control, mild global disease, and severe local disease groups (p < 0.0001). A heterogeneity index was calculated to describe the difference of an individual variogram from

  9. Contribution to the study of markers in lungs carcinogenesis and analysis of factors predicting the benefit of chemotherapy

    International Nuclear Information System (INIS)

    Olaussen, K.A.

    2006-06-01

    A better definition of early bio markers in lung carcinogenesis should enhance the development of molecular means to perform screening, diagnostic, and chemo-prevention of patients at high risk of lung cancer. We studied epigenetic deregulation of multiple promoters (p16(INK4a), HOX A9, MAGE A 1 et MAGE B2) in sputum samples from smokers at high risk and from patients with non-small cell lung cancer (N.S.C.L.C.). This molecular test, based on easily accessible sample,s can be modulated according to the aims of the investigator (e.g. screening or confirmation of diagnosis). Secondly, we have studied two candidate proteins as predictive markers of the benefit of adjuvant chemotherapy in patients with resected lung cancer. The multivariate analysis shows that tumor expression of the catalytic sub-unit of telomerase is not able to predict survival in patients included in the lAL T study' of adjuvant chemotherapy. However, tumor expression of the DNA repair protein ERCC1 identifies a sub-group of patients (ERCC1 negative) whose chances of survival are increased by 35% by means of cisplatin-based adjuvant chemotherapy. Further, tumor ERCC1 expression has a positive prognostic value in the non-treated control group. The need for a deeper understanding in cancerology of the physiological role of the ERCC1 endonuclease is discussed in this thesis. (author)

  10. Effect of nocturnal sound reduction on the incidence of delirium in intensive care unit patients: An interrupted time series analysis.

    Science.gov (United States)

    van de Pol, Ineke; van Iterson, Mat; Maaskant, Jolanda

    2017-08-01

    Delirium in critically-ill patients is a common multifactorial disorder that is associated with various negative outcomes. It is assumed that sleep disturbances can result in an increased risk of delirium. This study hypothesized that implementing a protocol that reduces overall nocturnal sound levels improves quality of sleep and reduces the incidence of delirium in Intensive Care Unit (ICU) patients. This interrupted time series study was performed in an adult mixed medical and surgical 24-bed ICU. A pre-intervention group of 211 patients was compared with a post-intervention group of 210 patients after implementation of a nocturnal sound-reduction protocol. Primary outcome measures were incidence of delirium, measured by the Intensive Care Delirium Screening Checklist (ICDSC) and quality of sleep, measured by the Richards-Campbell Sleep Questionnaire (RCSQ). Secondary outcome measures were use of sleep-inducing medication, delirium treatment medication, and patient-perceived nocturnal noise. A significant difference in slope in the percentage of delirium was observed between the pre- and post-intervention periods (-3.7% per time period, p=0.02). Quality of sleep was unaffected (0.3 per time period, p=0.85). The post-intervention group used significantly less sleep-inducing medication (psound-reduction protocol. However, reported sleep quality did not improve. Copyright © 2017. Published by Elsevier Ltd.

  11. Electromagnetic sounding of the Earth's interior

    CERN Document Server

    Spichak, Viacheslav V

    2015-01-01

    Electromagnetic Sounding of the Earth's Interior 2nd edition provides a comprehensive up-to-date collection of contributions, covering methodological, computational and practical aspects of Electromagnetic sounding of the Earth by different techniques at global, regional and local scales. Moreover, it contains new developments such as the concept of self-consistent tasks of geophysics and , 3-D interpretation of the TEM sounding which, so far, have not all been covered by one book. Electromagnetic Sounding of the Earth's Interior 2nd edition consists of three parts: I- EM sounding methods, II- Forward modelling and inversion techniques, and III - Data processing, analysis, modelling and interpretation. The new edition includes brand new chapters on Pulse and frequency electromagnetic sounding for hydrocarbon offshore exploration. Additionally all other chapters have been extensively updated to include new developments. Presents recently developed methodological findings of the earth's study, including seism...

  12. Lung Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Lung Emergencies Surgeries Lung Emergencies People with Marfan syndrome can be at increased risk of sudden lung ...

  13. A Histomorphological Pattern Analysis of Pulmonary Tuberculosis in Lung Autopsy and Surgically Resected Specimens

    Directory of Open Access Journals (Sweden)

    Mamta Gupta

    2016-01-01

    Full Text Available Background. Tuberculosis (TB is a major cause of morbidity and mortality globally. Many cases are diagnosed on autopsy and a subset of patients may require surgical intervention either due to the complication or sequelae of TB. Materials and Methods. 40 cases of resected lung specimens following surgery or autopsy in which a diagnosis of pulmonary tuberculosis was made were included. Histopathological pattern analysis of pulmonary tuberculosis along with associated nonneoplastic changes and identification of Mycobacterium tuberculosis bacilli was done. Results. The mean age of diagnosis was 41 years with male predominance (92.5%. Tuberculosis was suspected in only 12.1% of cases before death. Seven cases were operated upon due to associated complications or suspicion of malignancy. Tubercular consolidation was the most frequent pattern followed by miliary tuberculosis. The presence of necrotizing granulomas was seen in 33 cases (82.5%. Acid fast bacilli were seen in 57.5% cases on Ziehl-Neelsen stain. Conclusion. Histopathology remains one of the most important methods for diagnosing tuberculosis, especially in TB prevalent areas. It should be considered in the differential diagnosis of all respiratory diseases because of its varied clinical presentations and manifestations.

  14. Lobar analysis of collapsibility indices to assess functional lung volumes in COPD patients.

    Science.gov (United States)

    Kitano, Mariko; Iwano, Shingo; Hashimoto, Naozumi; Matsuo, Keiji; Hasegawa, Yoshinori; Naganawa, Shinji

    2014-01-01

    We investigated correlations between lung volume collapsibility indices and pulmonary function test (PFT) results and assessed lobar differences in chronic obstructive pulmonary disease (COPD) patients, using paired inspiratory and expiratory three dimensional (3D) computed tomography (CT) images. We retrospectively assessed 28 COPD patients who underwent paired inspiratory and expiratory CT and PFT exams on the same day. A computer-aided diagnostic system calculated total lobar volume and emphysematous lobar volume (ELV). Normal lobar volume (NLV) was determined by subtracting ELV from total lobar volume, both for inspiratory phase (NLVI) and for expiratory phase (NLVE). We also determined lobar collapsibility indices: NLV collapsibility ratio (NLVCR) (%)=(1-NLVE/NLVI)×100%. Associations between lobar volumes and PFT results, and collapsibility indices and PFT results were determined by Pearson correlation analysis. NLVCR values were significantly correlated with PFT results. Forced expiratory volume in 1 second, measured as percent of predicted results (FEV1%P) was significantly correlated with NLVCR values for the lower lobes (Pvolume, measured as percent of predicted (DLCO/VA%P) results were strongly correlated with ELVI for the upper lobes (Ppulmonary function in COPD patients.

  15. Cost analysis of adverse events associated with non-small cell lung cancer management in France

    Directory of Open Access Journals (Sweden)

    Chouaid C

    2017-07-01

    , anemia (€5,752 per event, dehydration (€5,207 per event and anorexia (€4,349 per event. Costs were mostly driven by hospitalization costs.Conclusion: Among the AEs identified, a majority appeared to have an important economic impact, with a management cost of at least €2,000 per event mainly driven by hospitalization costs. This study may be of interest for economic evaluations of new interventions in NSCLC. Keywords: non-small cell lung cancer, adverse events, cost analysis, chemotherapy, immunotherapy

  16. Does Traumatic Donor Cause of Death Influence Outcome after Lung Transplantation? A Single-Centre Analysis.

    Science.gov (United States)

    Pilarczyk, Kevin; Heckmann, Jens; Carstens, Henning; Lubarski, Jura; Jakob, Heinz; Pizanis, Nikolaus; Kamler, Markus

    2017-08-01

    Background  Owing to the shortage of donor organs in lung transplantation (LuTX), liberalization of donor selection criteria has been proposed. However, some studies suggested that donor traumatic brain damage might influence posttransplantation allograft function. This article aimed to investigate the association of donor cause of death (DCD) and outcome after LuTX. Methods  A retrospective analysis of 186 consecutive double LuTXs at our institution from January 2000 to December 2008 was performed. DCD was categorized into traumatic brain injury (TBI) and nontraumatic brain injury (NTBI). In addition, NTBI was sub classified as spontaneous intracerebral bleeding (B), hypoxic brain damage (H), and intracerebral neoplasia (N). Results  DCD was classified as TBI in 50 patients (26.9%) and NTBI in 136 patients (73.1%): B in 112 patients (60.2%), H in 21 patients (11.3%), and N in 3 patients (1.6%). Young male donors predominated in group TBI (mean age 36.0 ± 14.5 vs. 42.8 ± 10.7, p  donor ventilation time, or paO 2 /FiO 2 before harvesting. TBI donors received significantly more blood (3.4 ± 3.8 vs. 1.8 ± 1.9, p  = 0.03). A chest trauma was evident only in group T ( n  = 7 [3.7%] vs. 0 [0%], p  donor death did not affect the following indices of graft function: length of postoperative ventilation, paO 2 /FiO 2 ratio up to 48 hours, and lung function up to 36 months. One- and three-year survival was comparable with 84.4 and 70.4% for TBI donors versus 89.4% and 69.2% for NTBI donors. Five-year survival tended to be lower in the TBI group but did not reach statistical significance (43.4 vs. 53.9%). Conclusion  This study indicates that traumatic DCD does not affect outcome after LuTX. These results can be achieved with an ideal donor management combined with an individual case-to-case evaluation by an experienced LuTX surgeon. Georg Thieme Verlag KG Stuttgart · New York.

  17. A novel human ex vivo model for the analysis of molecular events during lung cancer chemotherapy

    Directory of Open Access Journals (Sweden)

    Lang Dagmar S

    2007-06-01

    Full Text Available Abstract Background Non-small cell lung cancer (NSCLC causes most of cancer related deaths in humans and is characterized by poor prognosis regarding efficiency of chemotherapeutical treatment and long-term survival of the patients. The purpose of the present study was the development of a human ex vivo tissue culture model and the analysis of the effects of conventional chemotherapy, which then can serve as a tool to test new chemotherapeutical regimens in NSCLC. Methods In a short-term tissue culture model designated STST (Short-Term Stimulation of Tissues in combination with the novel *HOPE-fixation and paraffin embedding method we examined the responsiveness of 41 human NSCLC tissue specimens to the individual cytotoxic drugs carboplatin, vinorelbine or gemcitabine. Viability was analyzed by LIFE/DEAD assay, TUNEL-staining and colorimetric MTT assay. Expression of Ki-67 protein and of BrdU (bromodeoxyuridine uptake as markers for proliferation and of cleaved (activated effector caspase-3 as indicator of late phase apoptosis were assessed by immunohistochemistry. Transcription of caspase-3 was analyzed by RT-PCR. Flow cytometry was utilized to determine caspase-3 in human cancer cell lines. Results Viability, proliferation and apoptosis of the tissues were moderately affected by cultivation. In human breast cancer, small-cell lung cancer (SCLC and human cell lines (CPC-N, HEK proliferative capacity was clearly reduced by all 3 chemotherapeutic agents in a very similar manner. Cleavage of caspase-3 was induced in the chemo-sensitive types of cancer (breast cancer, SCLC. Drug-induced effects in human NSCLC tissues were less evident than in the chemo-sensitive tumors with more pronounced effects in adenocarcinomas as compared to squamous cell carcinomas. Conclusion Although there was high heterogeneity among the individual tumor tissue responses as expected, we clearly demonstrate specific multiple drug-induced effects simultaneously. Thus, STST

  18. Best lung function equations for the very elderly selected by survival analysis

    DEFF Research Database (Denmark)

    Miller, Martin R; Thinggaard, Mikael; Christensen, Kaare

    2014-01-01

    We evaluated which equations best predicted the lung function of a cohort of nonagenarians based on which best accounted for subsequent survival.In 1998, we measured lung function, grip strength and dementia score (Mini Mental State Examination (MMSE)) in a population-based sample of 2262 Danes...... with a hazard ratio for death of 1, 1.16, 1.32 and 1.60 respectively, compared with equations derived with the inclusion of elderly subjects.We conclude that extrapolating from NHANES III equations to predict lung function in nonagenarians gave better survival predictions from spirometry than when employing...... equations derived using very elderly subjects with possible selection bias. These findings can help inform how future lung function equations for the elderly are derived....

  19. Analysis of errors during medical and computerized diagnostics of spherical lung neoplasms

    International Nuclear Information System (INIS)

    Pozmogov, A.I.; Petruk, D.A.

    1985-01-01

    Reasons for errors in medical and computerized diagnostics of spherical lung neoplasms are studied based on material of 212 case records and clinicoroentgenological data; it should promote improvement of their diagnostics

  20. Overall and Central Obesity and Risk of Lung Cancer: A Pooled Analysis.

    NARCIS (Netherlands)

    Yu, Danxia; Zheng, Wei; Johansson, Mattias; Lan, Qing; Park, Yikyung; White, Emily; Matthews, Charles E; Sawada, Norie; Gao, Yu-Tang; Robien, Kim; Sinha, Rashmi; Langhammer, Arnulf; Kaaks, Rudolf; Giovannucci, Edward L; Liao, Linda M; Xiang, Yong-Bing; Lazovich, DeAnn; Peters, Ulrike; Zhang, Xuehong; Bueno-de-Mesquita, Bas; Willett, Walter C; Tsugane, Shoichiro; Takata, Yumie; Smith-Warner, Stephanie A; Blot, William; Shu, Xiao-Ou

    2018-01-01

    The obesity-lung cancer association remains controversial. Concerns over confounding by smoking and reverse causation persist. The influence of obesity type and effect modifications by race/ethnicity and tumor histology are largely unexplored.

  1. Immunohistochemical quantification of expression of a tight junction protein, claudin-7, in human lung cancer samples using digital image analysis method.

    Science.gov (United States)

    Lu, Zhe; Liu, Yi; Xu, Junfeng; Yin, Hongping; Yuan, Haiying; Gu, Jinjing; Chen, Yan-Hua; Shi, Liyun; Chen, Dan; Xie, Bin

    2018-03-01

    Tight junction proteins are correlated with cancer development. As the pivotal proteins in epithelial cells, altered expression and distribution of different claudins have been reported in a wide variety of human malignancies. We have previously reported that claudin-7 was strongly expressed in benign bronchial epithelial cells at the cell-cell junction while expression of claudin-7 was either altered with discontinued weak expression or completely absent in lung cancers. Based on these results, we continued working on the expression pattern of claudin-7 and its relationship with lung cancer development. We herein proposed a new Digital Image Classification, Fragmentation index, Morphological analysis (DICFM) method for differentiating the normal lung tissues and lung cancer tissues based on the claudin-7 immunohistochemical staining. Seventy-seven lung cancer samples were obtained from the Second Affiliated Hospital of Zhejiang University and claudin-7 immunohistochemical staining was performed. Based on C++ and Open Source Computer Vision Library (OpenCV, version 2.4.4), the DICFM processing module was developed. Intensity and fragmentation of claudin-7 expression, as well as the morphological parameters of nuclei were calculated. Evaluation of results was performed using Receiver Operator Characteristic (ROC) analysis. Agreement between these computational results and the results obtained by two pathologists was demonstrated. The intensity of claudin-7 expression was significantly decreased while the fragmentation was significantly increased in the lung cancer tissues compared to the normal lung tissues and the intensity was strongly positively associated with the differentiation of lung cancer cells. Moreover, the perimeters of the nuclei of lung cancer cells were significantly greater than that of the normal lung cells, while the parameters of area and circularity revealed no statistical significance. Taken together, our DICFM approach may be applied as an

  2. Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

    Energy Technology Data Exchange (ETDEWEB)

    Knybel, Lukas [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic); VŠB-Technical University of Ostrava, Ostrava (Czech Republic); Cvek, Jakub, E-mail: Jakub.cvek@fno.cz [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic); Molenda, Lukas; Stieberova, Natalie; Feltl, David [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic)

    2016-11-15

    Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P<.001). Motion amplitudes >15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P<.001). Interfraction variations and baseline changes >3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe

  3. Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

    International Nuclear Information System (INIS)

    Knybel, Lukas; Cvek, Jakub; Molenda, Lukas; Stieberova, Natalie; Feltl, David

    2016-01-01

    Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P 15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P 3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe tumors; higher interfraction amplitude variability indicated tumors in contact

  4. Lung Cancer Messages on Twitter: Content Analysis and Evaluation.

    Science.gov (United States)

    Sutton, Jeannette; Vos, Sarah C; Olson, Michele K; Woods, Chelsea; Cohen, Elisia; Gibson, C Ben; Phillips, Nolan Edward; Studts, Jamie L; Eberth, Jan M; Butts, Carter T

    2018-01-01

    The aim of this project was to describe and evaluate the levels of lung cancer communication across the cancer prevention and control continuum for content posted to Twitter during a 10-day period (September 30 to October 9) in 2016. Descriptive and inferential statistics were used to identify relationships between tweet characteristics in lung cancer communication on Twitter and user-level data. Overall, 3,000 tweets published between September 30 and October 9 were assessed by a team of three coders. Lung cancer-specific tweets by user type (individuals, media, and organizations) were examined to identify content and structural message features. The study also assessed differences by user type in the use of hashtags, directed messages, health topic focus, and lung cancer-specific focus across the cancer control continuum. Across the universe of lung cancer tweets, the majority of tweets focused on treatment and the use of pharmaceutical and research interventions, followed by awareness and prevention and risk topics. Among all lung cancer tweets, messages were most consistently tweeted by individual users, and personal behavioral mobilizing cues to action were rare. Lung cancer advocates, as well as patient and medical advocacy organizations, with an interest in expanding the reach and effectiveness of social media efforts should monitor the topical nature of public tweets across the cancer continuum and consider integrating cues to action as a strategy to increase engagement and behavioral activation pertaining to lung cancer reduction efforts. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. Interstitial lung disease in gefitinib-treated Japanese patients with non-small cell lung cancer – a retrospective analysis: JMTO LC03-02

    Directory of Open Access Journals (Sweden)

    Tada Harue

    2009-08-01

    Full Text Available Abstract Background In Japan, high incidences of interstitial lung disease (ILD and ILD-related deaths have been reported among gefitinib-treated patients with non-small cell lung cancer (NSCLC. We investigated the efficacy of gefitinib, the incidence of ILD and risk factors for ILD in these patients. Findings We obtained patient data retrospectively using questionnaires sent to 22 institutions. We asked for demographic and clinical data on NSCLC patients for whom gefitinib treatment had begun between July 2002 and February 2003. Data from a total of 526 patients were analyzed. The patient characteristics were as follows: 64% male, 69% with adenocarcinoma, 61% with a performance score of 0–1, and 5% with concurrent interstitial pneumonitis. The objective response proportion was 80/439 (18.2%; 95% CI: 14.7–22.0. ILD developed in 17 patients (3.2%; 95% CI 1.9–5.1%, of whom 7 died. According to multivariate analysis, female sex, history of prior chemotherapy, low absolute neutrophil count before gefitinib treatment, and adenocarcinoma histology were associated with response to gefitinib treatment. None of the factors we evaluated were associated with the development of ILD. Conclusion The results of this study are consistent with previously published values for treatment response proportions and incidence of ILD during gefitinib treatment in Japanese patients. Future studies should be aimed at identifying factors indicating that a patient has a high probability of receiving benefit from gefitinib and a low risk of developing ILD.

  6. Nutrition for Lung Cancer

    Science.gov (United States)

    ... Become An Advocate Volunteer Ways To Give Lung Cancer www.lung.org > Lung Health and Diseases > Lung Disease Lookup > ... Cancer Learn About Lung Cancer What Is Lung Cancer Lung Cancer Basics Causes & Risk Factors Lung Cancer Staging ...

  7. A Analysis of the Low Frequency Sound Field in Non-Rectangular Enclosures Using the Finite Element Method.

    Science.gov (United States)

    Geddes, Earl Russell

    The details of the low frequency sound field for a rectangular room can be studied by the use of an established analytic technique--separation of variables. The solution is straightforward and the results are well-known. A non -rectangular room has boundary conditions which are not separable and therefore other solution techniques must be used. This study shows that the finite element method can be adapted for use in the study of sound fields in arbitrary shaped enclosures. The finite element acoustics problem is formulated and the modification of a standard program, which is necessary for solving acoustic field problems, is examined. The solution of the semi-non-rectangular room problem (one where the floor and ceiling remain parallel) is carried out by a combined finite element/separation of variables approach. The solution results are used to construct the Green's function for the low frequency sound field in five rooms (or data cases): (1) a rectangular (Louden) room; (2) The smallest wall of the Louden room canted 20 degrees from normal; (3) The largest wall of the Louden room canted 20 degrees from normal; (4) both the largest and the smallest walls are canted 20 degrees; and (5) a five-sided room variation of Case 4. Case 1, the rectangular room was calculated using both the finite element method and the separation of variables technique. The results for the two methods are compared in order to access the accuracy of the finite element method models. The modal damping coefficient are calculated and the results examined. The statistics of the source and receiver average normalized RMS P('2) responses in the 80 Hz, 100 Hz, and 125 Hz one-third octave bands are developed. The receiver averaged pressure response is developed to determine the effect of the source locations on the response. Twelve source locations are examined and the results tabulated for comparison. The effect of a finite sized source is looked at briefly. Finally, the standard deviation of the

  8. Patient satisfaction after pulmonary resection for lung cancer: a multicenter comparative analysis.

    Science.gov (United States)

    Pompili, Cecilia; Brunelli, Alessandro; Rocco, Gaetano; Salvi, Rosario; Xiumé, Francesco; La Rocca, Antonello; Sabbatini, Armando; Martucci, Nicola

    2013-01-01

    Patient satisfaction reflects the perception of the customer about the level of quality of care received during the episode of hospitalization. To compare the levels of satisfaction of patients submitted to lung resection in two different thoracic surgical units. Prospective analysis of 280 consecutive patients submitted to pulmonary resection for neoplastic disease in two centers (center A: 139 patients; center B: 141 patients; 2009-2010). Patients' satisfaction was assessed at discharge through the EORTC-InPatSat32 module, a 32-item, multi-scale self-administered anonymous questionnaire. Each scale (ranging from 0 to 100 in score) was compared between the two units. Multivariable regression and bootstrap were used to verify factors associated with the patients' general satisfaction (dependent variable). Patients from unit B reported a higher general satisfaction (91.5 vs. 88.3, p = 0.04), mainly due to a significantly higher satisfaction in the doctor-related scales (doctors' technical skill: p = 0.001; doctors' interpersonal skill: p = 0.008; doctors' availability: p = 0.005, and doctors information provision: p = 0.0006). Multivariable regression analysis and bootstrap confirmed that level of care in unit B (p = 0.006, bootstrap frequency 60%) along with lower level of education of the patient population (p = 0.02, bootstrap frequency 62%) were independent factors associated with a higher general patient satisfaction. We were able to show a different level of patient satisfaction in patients operated on in two different thoracic surgery units. A reduced level of patient satisfaction may trigger changes in the management policy of individual units in order to meet patients' expectations and improve organizational efficiency. Copyright © 2012 S. Karger AG, Basel.

  9. Classification of Non-Small Cell Lung Cancer Using Significance Analysis of Microarray-Gene Set Reduction Algorithm

    Directory of Open Access Journals (Sweden)

    Lei Zhang

    2016-01-01

    Full Text Available Among non-small cell lung cancer (NSCLC, adenocarcinoma (AC, and squamous cell carcinoma (SCC are two major histology subtypes, accounting for roughly 40% and 30% of all lung cancer cases, respectively. Since AC and SCC differ in their cell of origin, location within the lung, and growth pattern, they are considered as distinct diseases. Gene expression signatures have been demonstrated to be an effective tool for distinguishing AC and SCC. Gene set analysis is regarded as irrelevant to the identification of gene expression signatures. Nevertheless, we found that one specific gene set analysis method, significance analysis of microarray-gene set reduction (SAMGSR, can be adopted directly to select relevant features and to construct gene expression signatures. In this study, we applied SAMGSR to a NSCLC gene expression dataset. When compared with several novel feature selection algorithms, for example, LASSO, SAMGSR has equivalent or better performance in terms of predictive ability and model parsimony. Therefore, SAMGSR is a feature selection algorithm, indeed. Additionally, we applied SAMGSR to AC and SCC subtypes separately to discriminate their respective stages, that is, stage II versus stage I. Few overlaps between these two resulting gene signatures illustrate that AC and SCC are technically distinct diseases. Therefore, stratified analyses on subtypes are recommended when diagnostic or prognostic signatures of these two NSCLC subtypes are constructed.

  10. Parietal pleural invasion/adhesion of subpleural lung cancer: Quantitative 4-dimensional CT analysis using dynamic-ventilatory scanning

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Kotaro, E-mail: ksakuma@ohara-hp.or.jp [Department of Radiology, Ohara General Hospital, 6-11 Omachi, Fukushima City, Fukushima 960-8611 (Japan); Department of Radiology and Nuclear Medicine, Fukushima Medical University, 1 Hikariga-oka, Fukushima City, Fukushima 960-1295 (Japan); Yamashiro, Tsuneo, E-mail: clatsune@yahoo.co.jp [Department of Radiology, University of the Ryukyus, 207 Uehara, Nishihara, Okinawa 903-0215 (Japan); Moriya, Hiroshi, E-mail: hrshmoriya@gmail.com [Department of Radiology, Ohara General Hospital, 6-11 Omachi, Fukushima City, Fukushima 960-8611 (Japan); Murayama, Sadayuki, E-mail: sadayuki@med.u-ryukyu.ac.jp [Department of Radiology, University of the Ryukyus, 207 Uehara, Nishihara, Okinawa 903-0215 (Japan); Ito, Hiroshi, E-mail: h-ito@fmu.ac.jp [Department of Radiology and Nuclear Medicine, Fukushima Medical University, 1 Hikariga-oka, Fukushima City, Fukushima 960-1295 (Japan)

    2017-02-15

    Highlights: • 4DCT can be used for assessment of pleural invasion/adhesion by lung cancer. • Quantitative 4DCT indices of lung cancer and adjacent structures are described. • An automatic analysis of pleural invasion/adhesion would be developed in the future. - Abstract: Purpose: Using 4-dimensional dynamic-ventilatory scanning by a 320-row computed tomography (CT) scanner, we performed a quantitative assessment of parietal pleural invasion and adhesion by peripheral (subpleural) lung cancers. Methods: Sixteen patients with subpleural lung cancer underwent dynamic-ventilation CT during free breathing. Neither parietal pleural invasion nor adhesion was subsequently confirmed by surgery in 10 patients, whereas the other 6 patients were judged to have parietal pleural invasion or adhesion. Using research software, we tracked the movements of the cancer and of an adjacent structure such as the rib or aorta, and converted the data to 3-dimensional loci. The following quantitative indices were compared by the Mann-Whitney test: cross-correlation coefficient between time curves for the distances moved from the inspiratory frame by the cancer and the adjacent structure, the ratio of the total movement distances (cancer/adjacent structure), and the cosine similarities between the inspiratory and expiratory vectors (from the cancer to the adjacent structure) and between vectors of the cancer and of the adjacent structure (from inspiratory to expiratory frames). Results: Generally, the movements of the loci of the lung cancer and the adjacent structure were similar in patients with parietal pleural invasion/adhesion, while they were independent in patients without. There were significant differences in all the parameters between the two patient groups (cross-correlation coefficient and the movement distance ratio, P < 0.01; cosine similarities, P < 0.05). Conclusion: These observations suggest that quantitative indices by dynamic-ventilation CT can be utilized as a

  11. Cases study of lung cancer deaths and analysis of radon levels in house-room of Mexicali, B. C

    International Nuclear Information System (INIS)

    Lopez B, G.; Reyna C, M. A.

    2009-10-01

    The lung cancer is a case of health of more importance as much in women as in men, with more frequency that the cancer of mamma, colon and prostate on the whole. A factor that influences in the cancer generation originating serious complications it is the exposition to radioactive substances in closed places, as house-room. In the investigation study, levels of radon concentration were measured in interiors of Mexicali homes, to study the relationship that this gas could have with the death cases by lung cancer into population. The gas radon is radioactive and it adheres easily to particles that remain suspended in air; when inhaling them small explosions take place inside the alveoli, changing the DNA of cells and lung cancer is generated. The meteorological, geographical and urban characteristics of Mexicali, favor conditions so that certain areas of the city present high indexes of suspended particles in atmosphere. One sample of gas radon inside 100 house-rooms, the analysis was made by paved and not paved colonies and for sex, to establish if the death cases by lung cancer had relationship with the genus and/or with some of two groups of colonies. The study found that the major number of deaths it was presented in colonies in which lacked the paving service and always happened with more frequency in women; and that in homes of having died by lung cancer the radon concentrations were more high that the homes where there was not death cases, with significant differences that go from 9.2% to 70%. This investigation project is presented as a cases study in the Mexicali City. (Author)

  12. A cross sectional analysis of the role of the antimicrobial peptide cathelicidin in lung function impairment within the ALIVE cohort.

    Directory of Open Access Journals (Sweden)

    Allison A Lambert

    Full Text Available Vitamin D deficiency is associated with reduced lung function. Cathelicidin, an antimicrobial peptide regulated by vitamin D, plays a role within the innate immune system. The association of cathelicidin with lung function decrement and respiratory infection is undefined. We determined the independent relationship of cathelicidin with lung function.In a cross-sectional analysis of 650 participants in an urban observational cohort with high smoking prevalence, plasma 25(OH-vitamin D and cathelicidin levels were measured from stored samples obtained within 6 months of spirometry study visits. Multivariable linear regression was used to determine the independent association between low cathelicidin (defined as the lowest quartile of the cohort and absolute forced expiratory volume in 1 second (FEV1.The mean age of the cohort was 49 years; 91% were black, 35% female and 41% HIV-infected. Participants with low cathelicidin had a 183 mL lower FEV1 compared to higher cathelicidin (p = 0.009; this relationship was maintained (115 ml lower; p = 0.035 after adjusting for demographics, BMI, and smoking. Neither HIV serostatus, heavy smoking history, nor 25(OH-vitamin D levels were associated with cathelicidin levels. Participants with low cathelicidin had a greater prevalence of prior bacterial pneumonia (21% versus 14%; p = 0.047. Inclusion of pneumonia in adjusted models did not substantially reduce the FEV1 decrement observed with low cathelicidin (104 mL lower FEV1; p = 0.05. Lung function decrements associated with low cathelicidin were greatest among individuals with lower 25(OH-vitamin D levels.In a cohort at risk for airflow obstruction, low cathelicidin was independently associated with lower FEV1. These clinical data support a mechanistic link between 25(OH-vitamin D deficiency and lung function impairment, independent of pneumonia risk.

  13. Analysis of the plasma proteome in COPD: Novel low abundance proteins reflect the severity of lung remodeling.

    Science.gov (United States)

    Merali, Salim; Barrero, Carlos A; Bowler, Russell P; Chen, Diane Er; Criner, Gerard; Braverman, Alan; Litwin, Samuel; Yeung, Anthony; Kelsen, Steven G

    2014-04-01

    The search for COPD biomarkers has largely employed a targeted approach that focuses on plasma proteins involved in the systemic inflammatory response and in lung injury and repair. This proof of concept study was designed to test the idea that an open, unbiased, in-depth proteomics approach could identify novel, low abundance plasma proteins i.e., ng/mL concentration, which could serve as potential biomarkers. Differentially expressed proteins were identified in a discovery group with severe COPD (FEV1 <45% predicted; n = 10). Subjects with normal lung function matched for age, sex, ethnicity and smoking history served as controls (n = 10). Pooled plasma from each group was exhaustively immunodepleted of abundant proteins, d separated by 1-D gel electrophoresis and extensively fractionated prior to LC-tandem mass spectroscopy (GeLC-MS). Thirty one differentially expressed proteins were identified in the discovery group including markers of lung defense against oxidant stress, alveolar macrophage activation, and lung tissue injury and repair. Four of the 31 proteins (i.e., GRP78, soluble CD163, IL1AP and MSPT9) were measured in a separate verification group of 80 subjects with varying COPD severity by immunoassay. All 4 were significantly altered in COPD and 2 (GRP78 and soluble CD163) correlated with both FEV1 and the extent of emphysema. In-depth, plasma proteomic analysis identified a group of novel, differentially expressed, low abundance proteins that reflect known pathogenic mechanisms and the severity of lung remodeling in COPD. These proteins may also prove useful as COPD biomarkers.

  14. Association studies of ERCC1 polymorphisms with lung cancer susceptibility: a systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Jinhong Zhu

    Full Text Available BACKGROUND: Excision repair cross-complimentary group 1 (ERCC1 is an essential component of the nucleotide excision repair system that is responsible for repairing damaged DNA. Functional genetic variations in the ERCC1 gene may alter DNA repair capacity and modulate cancer risk. The putative roles of ERCC1 gene polymorphisms in lung cancer susceptibility have been widely investigated. However, the results remain controversial. OBJECTIVES: An updated meta-analysis was conducted to explore whether lung cancer risk could be attributed to the following ERCC1 polymorphisms: rs11615 (T>C, rs3212986 (C>A, rs3212961 (A>C, rs3212948 (G>C, rs2298881 (C>A. METHODS: Several major databases (MEDLINE, EMBASE and Scopus and the Chinese Biomedical database were searched for eligible studies. Crude odds ratios (ORs with 95% confidence intervals (CIs were used to measure the strength of associations. RESULTS: Sixteen studies with 10,106 cases and 13,238 controls were included in this meta-analysis. Pooled ORs from 11 eligible studies (8,215 cases vs. 11,402 controls suggested a significant association of ERCC1 rs11615 with increased risk for lung cancer (homozygous: CC versus TT, OR = 1.24, 95% CI: 1.04-1.48, P = 0.02. However, such an association was disproportionately driven by a single study. Removal of that study led to null association. Moreover, initial analyses suggested that ERCC1 rs11615 exerts a more profound effect on the susceptibility of non-smokers to lung cancer than that of smokers. Moreover, no statistically significant association was found between remaining ERCC1 polymorphisms of interest and lung cancer risk, except for rs3212948 variation (heterozygous: CG vs.GG, OR = 0.78, 95% CI: 0.67-0.90, P = 0.001; dominant: CG/CC vs.GG, OR = 0.79, 95% CI: 0.69-0.91, P = 0.001. CONCLUSION: Overall, this meta-analysis suggests that ERCC1 rs3212948 G>C, but not others, is a lung cancer risk-associated polymorphism. Carefully

  15. Diagnostic value of tumor markers for lung adenocarcinoma-associated malignant pleural effusion: a validation study and meta-analysis.

    Science.gov (United States)

    Feng, Mei; Zhu, Jing; Liang, Liqun; Zeng, Ni; Wu, Yanqiu; Wan, Chun; Shen, Yongchun; Wen, Fuqiang

    2017-04-01

    Pleural effusion is one of the most common complications of lung adenocarcinoma and is diagnostically challenging. This study aimed to investigate the diagnostic performance of carcinoembryonic antigen (CEA), cytokeratin fragment (CYFRA) 21-1, and cancer antigen (CA) 19-9 for lung adenocarcinoma-associated malignant pleural effusion (MPE) through a validation study and meta-analysis. Pleural effusion samples were collected from 81 lung adenocarcinoma-associated MPEs and 96 benign pleural effusions. CEA, CYFRA 21-1, and CA19-9 were measured by electrochemiluminescence immunoassay. The capacity of tumor markers was assessed with receiver operating characteristic curve analyses and the area under the curve (AUC) was calculated. Standard methods for meta-analysis of diagnostic studies were used to summarize the diagnostic performance of CEA, CYFRA 21-1, and CA19-9 for lung adenocarcinoma-associated MPE. The pleural levels of CEA, CYFRA 21-1, and CA19-9 were significantly increased in lung adenocarcinoma-associated MPE compared to benign pleural effusion. The cut-off points for CEA, CYFRA 21-1, and CA19-9 were optimally set at 4.55 ng/ml, 43.10 μg/ml, and 12.89 U/ml, and corresponding AUCs were 0.93, 0.85, and 0.81, respectively. The combination of CEA, CYFRA 21-1, and CA19-9 increased the sensitivity to 95.06%, with an AUC of 0.95. Eight studies were included in this meta-analysis. CEA showed the best diagnostic performance with pooled sensitivity, specificity, positive/negative likelihood ratio, and diagnostic odds ratio of 0.75, 0.96, 16.01, 0.23, and 81.49, respectively. The AUC was 0.93. CEA, CYFRA 21-1, and CA19-9 play a role in the diagnosis of lung adenocarcinoma-associated MPE. The combination of these tumor markers increases the diagnostic accuracy.

  16. Causes of death and competing risk analysis of the associated factors for non-small cell lung cancer using the Surveillance, Epidemiology, and End Results database.

    Science.gov (United States)

    Wei, Shenhai; Tian, Jintao; Song, Xiaoping; Wu, Bingqun; Liu, Limin

    2018-01-01

    To investigate the probability of death (POD) from any causes by time after diagnosis of non-small cell lung cancer (NSCLC) and the factors associated with survival for NSCLC patients. A total of 202,914 patients with NSCLC from 2004 to 2013 were identified from the Surveillance, Epidemiology, and End Results (SEER) database. The overall survival (OS) and lung cancer-specific survival (LCSS) were calculated and POD from any causes at different time periods after diagnosis was explored. The predictive factors for OS, LCSS and survival from non-lung cancer deaths were investigated using multivariate analysis with Cox proportional hazards regression and competing risk regression analysis. The 5- and 10-year OS were 20.4% and 11.5%, accordingly that for LCSS were 25.5% and 18.4%, respectively. Lung cancer contributed 88.3% (n = 128,402) of the deaths. The POD from lung cancer decreased with time after diagnosis. In multivariate analysis, advanced age and advanced stage of NSCLC were associated with decreased OS and LCSS. Comparing to no surgery, any kind of resection conferred lower risk of death from lung cancer and higher risk of dying from non-lung cancer conditions except lobectomy or bilobectomy, which was associated with lower risk of death from both lung cancer and non-lung cancer conditions. Most of the patients with NSCLC died from lung cancer. Rational surveillance and treatment policies should be made for them. Early stage and lobectomy or bilobectomy were associated with improved OS and LCSS. It is reasonable to focus on early detection and optimal surgical treatment for NSCLC.

  17. Sound transmission analysis of plate structures using the finite element method and elementary radiator approach with radiator error index

    DEFF Research Database (Denmark)

    Jung, Jaesoon; Kook, Junghwan; Goo, Seongyeol

    2017-01-01

    combines the FEM and Elementary Radiator Approach (ERA) is proposed. The FE-ERA method analyzes the vibrational response of the plate structure excited by incident sound using FEM and then computes the transmitted acoustic pressure from the vibrating plate using ERA. In order to improve the accuracy...... and efficiency of the FE-ERA method, a novel criterion for the optimal number of elementary radiators is proposed. The criterion is based on the radiator error index that is derived to estimate the accuracy of the computation with used number of radiators. Using the proposed criterion a radiator selection method...... is presented for determining the optimum number of radiators. The presented radiator selection method and the FE-ERA method are combined to improve the computational accuracy and efficiency. Several numerical examples that have been rarely addressed in previous studies, are presented with the proposed method...

  18. 78 FR 13869 - Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy...

    Science.gov (United States)

    2013-03-01

    ...-123-LNG; 12-128-NG; 12-148-NG; 12- 158-NG] Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; CE FLNG, LLC; Consolidated...-NG Puget Sound Energy, Inc Order granting long- term authority to import/export natural gas from/to...

  19. Feasibility and safety of robot-assisted thoracic surgery for lung lobectomy in patients with non-small cell lung cancer: a systematic review and meta-analysis.

    Science.gov (United States)

    Wei, Shiyou; Chen, Minghao; Chen, Nan; Liu, Lunxu

    2017-05-08

    The aim of this study is to evaluate the feasibility and safety of robot-assisted thoracic surgery (RATS) lobectomy versus video-assisted thoracic surgery (VATS) for lobectomy in patients with non-small cell lung cancer (NSCLC). An electronic search of six electronic databases was performed to identify relevant comparative studies. Meta-analysis was performed by pooling the results of reported incidence of overall morbidity, mortality, prolonged air leak, arrhythmia, and pneumonia between RATS and VATS lobectomy. Subgroup analysis was also conducted based on matched and unmatched cohort studies, if possible. Relative risks (RR) with their 95% confidence intervals (CI) were calculated by means of Revman version 5.3. Twelve retrospective cohort studies were included, with a total of 60,959 patients. RATS lobectomy significantly reduced the mortality rate when compared with VATS lobectomy (RR = 0.54, 95% CI 0.38-0.77; P = 0.0006), but this was not consistent with the pooled result of six matched studies (RR = 0.12, 95% CI 0.01-1.07; P = 0.06). There was no significant difference in morbidity between the two approaches (RR = 0.97, 95% CI 0.85-1.12; P = 0.70). RATS lobectomy is a feasible and safe technique and can achieve an equivalent short-term surgical efficacy when compared with VATS, but its cost effectiveness also should be taken into consideration.

  20. The internal auditory clock: what can evoked potentials reveal about the analysis of temporal sound patterns, and abnormal states of consciousness?

    Science.gov (United States)

    Jones, S J

    2002-09-01

    Whereas in vision a large amount of information may in theory be extracted from instantaneous images, sound exists only in its temporal extent, and most of its information is contained in the pattern of changes over time. The "echoic memory" is a pre-attentive auditory sensory store in which sounds are apparently retained in full temporal detail for a period of a few seconds. From the long-latency auditory evoked potentials to spectro-temporal modulation of complex harmonic tones, at least two automatic sound analysis processes can be identified whose time constants suggest participation of the echoic memory. When a steady tone changes its pitch or timbre, "change-type" CP1, CN1 and CP2 potentials are maximally recorded near the vertex. These potentials appear to reflect a process concerned with the distribution of sound energy across the frequency spectrum. When, on the other hand, changes occur in the temporal pattern of tones (in which individual pitch changes are occurring at a rate sufficiently rapid for the C-potentials to be refractory), a large mismatch negativity (or MN1) and following positivity (MP2) are generated. The amplitude of these potentials is influenced by the degree of regularity of the pattern, larger responses being generated to a "deviant" tone when the pitch and time of occurrence of the "standards" are fully specified by the preceding pattern. At the sudden cessation of changes, on resumption of a steady pitch, a mismatch response is generated whose latency is determined with high precision (in the order of a few milliseconds) by the anticipated time of the next change, which did not in fact occur. The mismatch process, therefore, functions as spectro-temporal auditory pattern analyser, whose consequences are manifested each time the pattern changes. Since calibration of the passage of time is essential for all conscious and subconscious behaviour, is it possible that some states of unconsciousness may be directly due to disruption of

  1. Detecting change in stochastic sound sequences.

    Directory of Open Access Journals (Sweden)

    Benjamin Skerritt-Davis

    2018-05-01

    Full Text Available Our ability to parse our acoustic environment relies on the brain's capacity to extract statistical regularities from surrounding sounds. Previous work in regularity extraction has predominantly focused on the brain's sensitivity to predictable patterns in sound sequences. However, natural sound environments are rarely completely predictable, often containing some level of randomness, yet the brain is able to effectively interpret its surroundings by extracting useful information from stochastic sounds. It has been previously shown that the brain is sensitive to the marginal lower-order statistics of sound sequences (i.e., mean and variance. In this work, we investigate the brain's sensitivity to higher-order statistics describing temporal dependencies between sound events through a series of change detection experiments, where listeners are asked to detect changes in randomness in the pitch of tone sequences. Behavioral data indicate listeners collect statistical estimates to process incoming sounds, and a perceptual model based on Bayesian inference shows a capacity in the brain to track higher-order statistics. Further analysis of individual subjects' behavior indicates an important role of perceptual constraints in listeners' ability to track these sensory statistics with high fidelity. In addition, the inference model facilitates analysis of neural electroencephalography (EEG responses, anchoring the analysis relative to the statistics of each stochastic stimulus. This reveals both a deviance response and a change-related disruption in phase of the stimulus-locked response that follow the higher-order statistics. These results shed light on the brain's ability to process stochastic sound sequences.

  2. Investigations of mode I crack propagation in fibre-reinforced plastics with real time X-ray tests and simultaneous sound emission analysis

    International Nuclear Information System (INIS)

    Brunner, A.; Nordstrom, R.; Flueeler, P.

    1992-01-01

    The described investigation of crack formation and crack propagation in mode I (tensile stress) in fibre-reinforced plastic samples, especially uni-directional carbon fibre reinforced polyether-ether ketone (PEEK) has several aims. On the one hand, the phenomena of crack formation and crack propagation in these materials are to be studied, and on the other hand, the draft standards for these tests are to be checked. It was found that the combination of real time X-ray tests and simultaneous sound emission analysis is excellently suited for the basic examination of crack formation and crack propagation in DCB samples. With the aid of picture processing and analysis of the video representation, consistent crack lengths and resulting G IC values can be determined. (orig./RHM) [de

  3. Volume-controlled histographic analysis of pulmonary parenchyma in normal and diffuse parenchymal lung disease: a pilot study

    International Nuclear Information System (INIS)

    Park, Hyo Yong; Lee, Jongmin; Kim, Jong Seob; Won, Chyl Ho; Kang, Duk Sik; Kim, Myoung Nam

    2000-01-01

    To evaluate the clinical usefulness of a home-made histographic analysis system using a lung volume controller. Our study involved ten healthy volunteers, ten emphysema patients, and two idiopathic pulmonary fibrosis (IPF) patients. Using a home-made lung volume controller, images were obtained in the upper, middle, and lower lung zones at 70%, 50%, and 20% of vital capacity. Electron beam tomography was used and scanning parameters were single slice mode, 10-mm slice thickness, 0.4-second scan time, and 35-cm field of view. Usinga home-made semi-automated program, pulmonary parenchyma was isolated and a histogrm then obtained. Seven histographic parameters, namely mean density (MD), density at maximal frequency (DMF), maximal ascending gradient (MAG),maximal ascending gradient density (MAGD), maximal sescending gradient (MDG), maximal descending gradient density (MDGD), and full width at half maximum (FWHM) were derived from the histogram. We compared normal controls with abnormal groups including emphysema and IPF patients at the same respiration levels. A normal histographic zone with ± 1 standard deviation was obtained. Histographic curves of normal controls shifted toward the high density level, and the width of the normal zone increased as the level of inspiration decreased. In ten normal controls, MD, DMF, MAG, MAGD, MDG, MDGD, and FWHM readings at a 70% inspiration level were lower than those at 20% (p less than0.05). At the same level of inspiration, histograms of emphysema patients were locatedat a lower density area than those of normal controls. As inspiration status decreased, histograms of emphysema patients showed diminished shift compared with those of normal controls. At 50% and 20% inspiration levels, the MD, DMF, and MAGD readings of emphysema patients were significantly lower than those of normal controls (p less than 0.05). Compared with those of normal controls, histogrms of the two IPF patients obtained at three inspiration levels were

  4. Volume-controlled histographic analysis of pulmonary parenchyma in normal and diffuse parenchymal lung disease: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyo Yong; Lee, Jongmin; Kim, Jong Seob; Won, Chyl Ho; Kang, Duk Sik [School of Medicine, Kyungpook National University, Taegu (Korea, Republic of); Kim, Myoung Nam [The University of Iowa (United States)

    2000-06-01

    To evaluate the clinical usefulness of a home-made histographic analysis system using a lung volume controller. Our study involved ten healthy volunteers, ten emphysema patients, and two idiopathic pulmonary fibrosis (IPF) patients. Using a home-made lung volume controller, images were obtained in the upper, middle, and lower lung zones at 70%, 50%, and 20% of vital capacity. Electron beam tomography was used and scanning parameters were single slice mode, 10-mm slice thickness, 0.4-second scan time, and 35-cm field of view. Usinga home-made semi-automated program, pulmonary parenchyma was isolated and a histogrm then obtained. Seven histographic parameters, namely mean density (MD), density at maximal frequency (DMF), maximal ascending gradient (MAG),maximal ascending gradient density (MAGD), maximal sescending gradient (MDG), maximal descending gradient density (MDGD), and full width at half maximum (FWHM) were derived from the histogram. We compared normal controls with abnormal groups including emphysema and IPF patients at the same respiration levels. A normal histographic zone with {+-} 1 standard deviation was obtained. Histographic curves of normal controls shifted toward the high density level, and the width of the normal zone increased as the level of inspiration decreased. In ten normal controls, MD, DMF, MAG, MAGD, MDG, MDGD, and FWHM readings at a 70% inspiration level were lower than those at 20% (p less than0.05). At the same level of inspiration, histograms of emphysema patients were locatedat a lower density area than those of normal controls. As inspiration status decreased, histograms of emphysema patients showed diminished shift compared with those of normal controls. At 50% and 20% inspiration levels, the MD, DMF, and MAGD readings of emphysema patients were significantly lower than those of normal controls (p less than 0.05). Compared with those of normal controls, histogrms of the two IPF patients obtained at three inspiration levels were

  5. Analysis on Clinical Features of 2168 Patients with Lung Cancer Diagnosed by Bronchoscope

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2013-06-01

    Full Text Available Objective: To analyze the clinical features of lung cancer diagnosed by bronchoscopy. Methods: The clinical features of 2168 patients with lung cancer diagnosed by bronchoscopy were retrospectively analyzed, including gender, age, pathological type, diseased region, manifestations under bronchoscopy and methods of drawing materials. Results: The ratio of male/female was 4.8:1 and the peak onset age was 60 - 69 years old. The major pathological type was squamous cell carcinoma (44.5%, then adenocarcinoma (25.9% and small cell lung cancer (18.3%. The incidence of squamous cell carcinoma was the highest in males (50.6%, while that of adenocarcinoma in females (56.2%. The positive diagnostic rates of forceps biopsy, brush biopsy, bronchial alveolar lavage and transbronchial needle aspiration were 81.6%, 49.4%, 18.2% and 62.6%, respectively, whereas that of biopsy combined with brush biopsy came up to 89.0%. Conclusion: Bronchoscopy is an important method in diagnosis of lung cancer. Different ages and genders of patients with lung cancer have different onset, and the distribution of pathological types is diverse. Attaching more importance to bronchoscopy and improving biopsy technique can significantly improve the diagnostic rate and provide reliable evidences for clinical treatment.

  6. High-throughput molecular analysis in lung cancer: insights into biology and potential clinical applications.

    Science.gov (United States)

    Ocak, S; Sos, M L; Thomas, R K; Massion, P P

    2009-08-01

    During the last decade, high-throughput technologies including genomic, epigenomic, transcriptomic and proteomic have been applied to further our understanding of the molecular pathogenesis of this heterogeneous disease, and to develop strategies that aim to improve the management of patients with lung cancer. Ultimately, these approaches should lead to sensitive, specific and noninvasive methods for early diagnosis, and facilitate the prediction of response to therapy and outcome, as well as the identification of potential novel therapeutic targets. Genomic studies were the first to move this field forward by providing novel insights into the molecular biology of lung cancer and by generating candidate biomarkers of disease progression. Lung carcinogenesis is driven by genetic and epigenetic alterations that cause aberrant gene function; however, the challenge remains to pinpoint the key regulatory control mechanisms and to distinguish driver from passenger alterations that may have a small but additive effect on cancer development. Epigenetic regulation by DNA methylation and histone modifications modulate chromatin structure and, in turn, either activate or silence gene expression. Proteomic approaches critically complement these molecular studies, as the phenotype of a cancer cell is determined by proteins and cannot be predicted by genomics or transcriptomics alone. The present article focuses on the technological platforms available and some proposed clinical applications. We illustrate herein how the "-omics" have revolutionised our approach to lung cancer biology and hold promise for personalised management of lung cancer.

  7. Application Effect of Fast Track Surgery for Patients with Lung Cancer: 
A Meta-analysis

    Directory of Open Access Journals (Sweden)

    Yan XIA

    2016-12-01

    Full Text Available Background and objective Fast track surgery (FTS can accelerate rehabilitation and reduce postoperative hospital stay. It has been effectively applied to several surgical diseases. However, the safety and effectiveness of FTS for patients with lung cancer in China is unclear. This meta-analysis aimed to evaluate the effect of FTS undergoing lung cancer surgery in China. Methods Using home and abroad databases to search all documents required. The deadline of retrieval was January 31, 2016. Then the studies were screened according to the inclusion and exclusion criteria. Data were analyzed by RevMan 5.3 software. Results 8 randomized controlled trials (RCTs and 5 clinical controlled trials (CCTs with 1,241 patients were eligible for analysis. Compared with control group, FTS group can significantly shorten postoperative hospital time (MD=-3.61, 95%CI: -5.05--2.16, P<0.000,01 and chest tube duration (MD=-2.62, 95%CI: -3.07-2.17, P<0.000,01, reduce incidence of postoperative complications (OR=0.30, 95%CI: 0.19-0.47, P<0.000,01 and hospitalization costs (MD=-0.92, 95%CI: -1.19--0.65, P<0.000,01. Conclusion FTS can safely and effectively accelerate the recovery of patients with lung cancer in China, it exhibits important clinical values.

  8. Endobronchial valves in severe emphysematous patients: CT evaluation of lung fissures completeness, treatment radiological response and quantitative emphysema analysis

    Energy Technology Data Exchange