WorldWideScience

Sample records for lung ct perfusion

  1. Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer.

    Science.gov (United States)

    Chen, Xiaoliang; Xu, Yanyan; Duan, Jianghui; Li, Chuandong; Sun, Hongliang; Wang, Wu

    2017-07-01

    To investigate the potential relationship between perfusion parameters from first-pass dual-input perfusion computed tomography (DI-PCT) and iodine uptake levels estimated from dual-energy CT (DE-CT).The pre-experimental part of this study included a dynamic DE-CT protocol in 15 patients to evaluate peak arterial enhancement of lung cancer based on time-attenuation curves, and the scan time of DE-CT was determined. In the prospective part of the study, 28 lung cancer patients underwent whole-volume perfusion CT and single-source DE-CT using 320-row CT. Pulmonary flow (PF, mL/min/100 mL), aortic flow (AF, mL/min/100 mL), and a perfusion index (PI = PF/[PF + AF]) were automatically generated by in-house commercial software using the dual-input maximum slope method for DI-PCT. For the dual-energy CT data, iodine uptake was estimated by the difference (λ) and the slope (λHU). λ was defined as the difference of CT values between 40 and 70 KeV monochromatic images in lung lesions. λHU was calculated by the following equation: λHU = |λ/(70 - 40)|. The DI-PCT and DE-CT parameters were analyzed by Pearson/Spearman correlation analysis, respectively.All subjects were pathologically proved as lung cancer patients (including 16 squamous cell carcinoma, 8 adenocarcinoma, and 4 small cell lung cancer) by surgery or CT-guided biopsy. Interobserver reproducibility in DI-PCT (PF, AF, PI) and DE-CT (λ, λHU) were relatively good to excellent (intraclass correlation coefficient [ICC]Inter = 0.8726-0.9255, ICCInter = 0.8179-0.8842; ICCInter = 0.8881-0.9177, ICCInter = 0.9820-0.9970, ICCInter = 0.9780-0.9971, respectively). Correlation coefficient between λ and AF, and PF were as follows: 0.589 (P input CT perfusion analysis method can be applied to assess blood supply of lung cancer patients. Preliminary results demonstrated that the iodine uptake relevant parameters derived from DE-CT significantly correlated with perfusion

  2. Quantitative study on lung volume and lung perfusion using SPECT and CT in thoracal tumors

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Strauss, L.G.

    1988-01-01

    22 patients with space occupying lesions in the thoracal region were investigated by computer tomography and by perfusion scintigraphy using SPECT. In order to evaluate the CT images quantitatively, the lung volume was determined using approximation method and compared with the perfusion in the SPECT study. For this, anatomically equivalent transaxial SPECT slices had been coordinated to the CT slices. Between the determined lung volumes and the activity in the ocrresponding layers, a statistically significant correlation was found. It could be shown that the stronger perfusion, frequently observed at the right side of the healthy lung, may be explained by an higher volume of the right pulmonary lobe. Whereas in benign displacing processes the relation activity to volume was similar to the one of the healthy lung, a strongly reduced perfusion together with inconspicuous lung volumes became apparent with malignant tumors. In addition to the great morphological evidence of CT and SPECT studies, additional informations regarding the dignity of displacing processes may be derived from the quantitative evaluation of both methods. (orig.) [de

  3. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    International Nuclear Information System (INIS)

    Thieme, Sven F.; Becker, Christoph R.; Hacker, Marcus; Nikolaou, Konstantin; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2008-01-01

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam

  4. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Becker, Christoph R. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Hacker, Marcus [Department of Nuclear Medicine, Ludwig-Maximilians-University of Munich (Germany); Nikolaou, Konstantin; Reiser, Maximilian F. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Johnson, Thorsten R.C. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany)], E-mail: thorsten.johnson@med.uni-muenchen.de

    2008-12-15

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.

  5. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    International Nuclear Information System (INIS)

    Suga, K.; Yasuhiko, K.; Iwanaga, H.; Tokuda, O.; Matsunaga, N.

    2009-01-01

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  6. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Suga, K.; Yasuhiko, K. (Dept. of Radiology, St. Hill Hospital, Ube, Yamaguchi (Japan)); Iwanaga, H.; Tokuda, O.; Matsunaga, N. (Dept. of Radiology, Yamaguchi Univ. School of Medicine, Ube, Yamaguchi (Japan))

    2009-01-15

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  7. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT.

    Science.gov (United States)

    Suga, K; Yasuhiko, K; Iwanaga, H; Tokuda, O; Matsunaga, N

    2009-01-01

    The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Although further validation is required, our results indicate that heterogeneous pulmonary arterial

  8. Reproducibility of Lobar Perfusion and Ventilation Quantification Using SPECT/CT Segmentation Software in Lung Cancer Patients.

    Science.gov (United States)

    Provost, Karine; Leblond, Antoine; Gauthier-Lemire, Annie; Filion, Édith; Bahig, Houda; Lord, Martin

    2017-09-01

    Planar perfusion scintigraphy with 99m Tc-labeled macroaggregated albumin is often used for pretherapy quantification of regional lung perfusion in lung cancer patients, particularly those with poor respiratory function. However, subdividing lung parenchyma into rectangular regions of interest, as done on planar images, is a poor reflection of true lobar anatomy. New tridimensional methods using SPECT and SPECT/CT have been introduced, including semiautomatic lung segmentation software. The present study evaluated inter- and intraobserver agreement on quantification using SPECT/CT software and compared the results for regional lung contribution obtained with SPECT/CT and planar scintigraphy. Methods: Thirty lung cancer patients underwent ventilation-perfusion scintigraphy with 99m Tc-macroaggregated albumin and 99m Tc-Technegas. The regional lung contribution to perfusion and ventilation was measured on both planar scintigraphy and SPECT/CT using semiautomatic lung segmentation software by 2 observers. Interobserver and intraobserver agreement for the SPECT/CT software was assessed using the intraclass correlation coefficient, Bland-Altman plots, and absolute differences in measurements. Measurements from planar and tridimensional methods were compared using the paired-sample t test and mean absolute differences. Results: Intraclass correlation coefficients were in the excellent range (above 0.9) for both interobserver and intraobserver agreement using the SPECT/CT software. Bland-Altman analyses showed very narrow limits of agreement. Absolute differences were below 2.0% in 96% of both interobserver and intraobserver measurements. There was a statistically significant difference between planar and SPECT/CT methods ( P software is highly reproducible. This tridimensional method yields statistically significant differences in measurements for right lung lobes when compared with planar scintigraphy. We recommend that SPECT/CT-based quantification be used for all lung

  9. Application of CT perfusion imaging in radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Xia Guangrong; Liu Guimei; He Wen; Jin Guohua; Xie Ruming; Xu Yongxiang; Li Xiaobo; Li Xuebing

    2011-01-01

    Objective: To investigate the value of CT perfusion imaging in evaluation of therapeutic effect and prognosis in radiotherapy for lung cancer. Methods: Fifty-one cases of lung cancer who were unable or refused to be operated on, 36 males and 15 females, aged 37-80, underwent CT perfusion imaging, 29 of which only before radiotherapy and 22 before and after radiotherapy twice. The images were collected by cine dynamic scanning (5 mm/4 slices) and input into the GE AW4.0 workstation for data processing. The slice positions of CT imaging were determined according to the largest tumor size in CT scan. Regions of interest of tumor were drawn at the region corresponding to the original images of CT perfusion. Radiotherapy was performed after CT perfusion imaging. Relevant parameters, including blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS) were calculated. The treatment response after radiotherapy was evaluated by RECIST. At 2 -4 weeks after the treatment, CT examination was conducted once more. Results: The tests of the 51 patients showed that the BV was 13.6 ml·100 g -1 , the BF was 129.5 ml·min -1 ·100 g -1 , the MTT was 9.1 s, and the PS was 10.0 ml· min -1 · 100 g -1 before radiotherapy. The tests of the 22 of the 51 patients showed that the values of BV and BF after radiotherapy were 7.6 ml· 100 g -1 and 97.8 ml·min -1 · 100 g -1 , respectively, both lower than those before radiotherapy (11.2 and 108.7 ml·min -1 ·100 g -1 , respectively), however, both not significantly (t=1.28, 0.40, P>0.05); and the values of MTT and PS after radiotherapy were 8.9 s and 7.8 ml·min -1 · 100 g -1 , respectively, both not significantly higher than those before radiotherapy (7.2 s and 6.8 ml· min -1 · 100 g -1 , respectively, t=-1.15, -0.57, P>0.05). The mean area of tumor after radiotherapy was 1189.6 mm 2 , significantly less than that before radiotherapy (1920.3 mm 2 , t=3.98, P<0.05). The MTT of the SCLC patients was 12

  10. Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Zaki, Mohammed; Yamashita, Tomio; Seto, Aska; Matsumoto, Tsuneo; Matsunaga, Naofumi

    2004-01-01

    In this study, respiratory-gated ventilation and perfusion single-photon emission tomography (SPET) were used to define regional functional impairment and to obtain reliable co-registration with computed tomography (CT) images in various lung diseases. Using a triple-headed SPET unit and a physiological synchroniser, gated perfusion SPET was performed in a total of 78 patients with different pulmonary diseases, including metastatic nodules (n=15); in 34 of these patients, it was performed in combination with gated technetium-99m Technegas SPET. Projection data were acquired using 60 stops over 120 for each detector. Gated end-inspiration and ungated images were reconstructed from 1/8 data centered at peak inspiration for each regular respiratory cycle and full respiratory cycle data, respectively. Gated images were registered with tidal inspiration CT images using automated three-dimensional (3D) registration software. Registration mismatch was assessed by measuring 3D distance of the centroid of the nine selected round perfusion-defective nodules. Gated SPET images were completed within 29 min, and increased the number of visible ventilation and perfusion defects by 9.7% and 17.2%, respectively, as compared with ungated images; furthermore, lesion-to-normal lung contrast was significantly higher on gated SPET images. In the nine round perfusion-defective nodules, gated images yielded a significantly better SPET-CT match compared with ungated images (4.9±3.1 mm vs 19.0±9.1 mm, P<0.001). The co-registered SPET-CT images allowed accurate perception of the location and extent of each ventilation/perfusion defect on the underlying CT anatomy, and characterised the pathophysiology of the various diseases. By reducing respiratory motion effects and enhancing perfusion/ventilation defect clarity, gated SPET can provide reliable co-registered images with CT images to accurately characterise regional functional impairment in various lung diseases. (orig.)

  11. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  12. Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates

    International Nuclear Information System (INIS)

    Takenaka, Daisuke; Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Onishi, Yumiko; Matsumoto, Keiko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2010-01-01

    Purpose: To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Materials and methods: Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV 1 ) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Results: Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60 ≤ r ≤ -0.42, p < 0.05). Conclusion: Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.

  13. Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates

    Energy Technology Data Exchange (ETDEWEB)

    Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.j [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2, Minatojima Minamimachi Chuo-ku, Kobe, Hyogo, 650-0047 (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Matsumoto, Keiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Department of Radiology, University of Yamanashi, 1110 Shimogato, Chuo, Yamanashi, 409-3898 (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan)

    2010-06-15

    Purpose: To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Materials and methods: Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV{sub 1}) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Results: Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60 {<=} r {<=} -0.42, p < 0.05). Conclusion: Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.

  14. Serial perfusion in native lungs in patients with idiopathic pulmonary fibrosis and other interstitial lung diseases after single lung transplantation.

    Science.gov (United States)

    Sokai, Akihiko; Handa, Tomohiro; Chen, Fengshi; Tanizawa, Kiminobu; Aoyama, Akihiro; Kubo, Takeshi; Ikezoe, Kohei; Nakatsuka, Yoshinari; Oguma, Tsuyoshi; Hirai, Toyohiro; Nagai, Sonoko; Chin, Kazuo; Date, Hiroshi; Mishima, Michiaki

    2016-04-01

    Lung perfusions after single lung transplantation (SLT) have not been fully clarified in patients with interstitial lung disease (ILD). The present study aimed to investigate temporal changes in native lung perfusion and their associated clinical factors in patients with ILD who have undergone SLT. Eleven patients were enrolled. Perfusion scintigraphy was serially performed up to 12 months after SLT. Correlations between the post-operative perfusion ratio in the native lung and clinical parameters, including pre-operative perfusion ratio and computed tomography (CT) volumetric parameters, were evaluated. On average, the perfusion ratio of the native lung was maintained at approximately 30% until 12 months after SLT. However, the ratio declined more significantly in idiopathic pulmonary fibrosis (IPF) than in other ILDs (p = 0.014). The perfusion ratio before SLT was significantly correlated with that at three months after SLT (ρ = 0.64, p = 0.048). The temporal change of the perfusion ratio in the native lung did not correlate with those of the CT parameters. The pre-operative perfusion ratio may predict the post-operative perfusion ratio of the native lung shortly after SLT in ILD. Perfusion of the native lung may decline faster in IPF compared with other ILDs. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Pulmonary ventilation and perfusion imaging with dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F. [Klinikum Grosshadern, Department of Clinical Radiology, Ludwig Maximilians University, Muenchen (Germany); Klinikum Grosshadern, Institut fuer Klinische Radiologie, LMU Muenchen, Muenchen (Germany); Hoegl, Sandra; Fisahn, Juergen; Irlbeck, Michael [Klinikum Grosshadern, Department of Anesthesiology, Ludwig Maximilians University, Muenchen (Germany); Nikolaou, Konstantin; Maxien, Daniel; Reiser, Maximilian F.; Becker, Christoph R.; Johnson, Thorsten R.C. [Klinikum Grosshadern, Department of Clinical Radiology, Ludwig Maximilians University, Muenchen (Germany)

    2010-12-15

    To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-enhanced perfusion mapping were performed in patients under artificial respiration. Parenchymal xenon and iodine distribution were mapped and correlated with structural or vascular abnormalities. In all datasets, image quality was sufficient for a comprehensive image reading of the pulmonary CTA images, lung window images and pulmonary functional parameter maps and led to expedient results in each patient. With dual-source CT systems, DECT of the lung with iodine or xenon administration is technically feasible and makes it possible to depict the regional iodine or xenon distribution representing the local perfusion and ventilation. (orig.)

  16. Perfusion CT of the Brain and Liver and of Lung Tumors: Use of Monte Carlo Simulation for Patient Dose Estimation for Examinations With a Cone-Beam 320-MDCT Scanner.

    Science.gov (United States)

    Cros, Maria; Geleijns, Jacob; Joemai, Raoul M S; Salvadó, Marçal

    2016-01-01

    The purpose of this study was to estimate the patient dose from perfusion CT examinations of the brain, lung tumors, and the liver on a cone-beam 320-MDCT scanner using a Monte Carlo simulation and the recommendations of the International Commission on Radiological Protection (ICRP). A Monte Carlo simulation based on the Electron Gamma Shower Version 4 package code was used to calculate organ doses and the effective dose in the reference computational phantoms for an adult man and adult woman as published by the ICRP. Three perfusion CT acquisition protocols--brain, lung tumor, and liver perfusion--were evaluated. Additionally, dose assessments were performed for the skin and for the eye lens. Conversion factors were obtained to estimate effective doses and organ doses from the volume CT dose index and dose-length product. The sex-averaged effective doses were approximately 4 mSv for perfusion CT of the brain and were between 23 and 26 mSv for the perfusion CT body protocols. The eye lens dose from the brain perfusion CT examination was approximately 153 mGy. The sex-averaged peak entrance skin dose (ESD) was 255 mGy for the brain perfusion CT studies, 157 mGy for the lung tumor perfusion CT studies, and 172 mGy for the liver perfusion CT studies. The perfusion CT protocols for imaging the brain, lung tumors, and the liver performed on a 320-MDCT scanner yielded patient doses that are safely below the threshold doses for deterministic effects. The eye lens dose, peak ESD, and effective doses can be estimated for other clinical perfusion CT examinations from the conversion factors that were derived in this study.

  17. Decreased Lung Perfusion After Breast/Chest Wall Irradiation: Quantitative Results From a Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Liss, Adam L., E-mail: adamliss68@gmail.com [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Marsh, Robin B. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kapadia, Nirav S. [Department of Radiation Oncology, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire (United States); McShan, Daniel L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Rogers, Virginia E. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Moran, Jean M.; Brock, Kristy K.; Schipper, Matt J.; Jagsi, Reshma [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Biostatistics Unit, University of Michigan, Ann Arbor, Michigan (United States); Flaherty, Kevin R. [Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Frey, Kirk A. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2017-02-01

    Purpose: To quantify lung perfusion changes after breast/chest wall radiation therapy (RT) using pre- and post-RT single photon emission computed tomography/computed tomography (SPECT/CT) attenuation-corrected perfusion scans; and correlate decreased perfusion with adjuvant RT dose for breast cancer in a prospective clinical trial. Methods and Materials: As part of an institutional review board–approved trial studying the impact of RT technique on lung function in node-positive breast cancer, patients received breast/chest wall and regional nodal irradiation including superior internal mammary node RT to 50 to 52.2 Gy with a boost to the tumor bed/mastectomy scar. All patients underwent quantitative SPECT/CT lung perfusion scanning before RT and 1 year after RT. The SPECT/CT scans were co-registered, and the ratio of decreased perfusion after RT relative to the pre-RT perfusion scan was calculated to allow for direct comparison of SPECT/CT perfusion changes with delivered RT dose. The average ratio of decreased perfusion was calculated in 10-Gy dose increments from 0 to 60 Gy. Results: Fifty patients had complete lung SPECT/CT perfusion data available. No patient developed symptoms consistent with pulmonary toxicity. Nearly all patients demonstrated decreased perfusion in the left lung according to voxel-based analyses. The average ratio of lung perfusion deficits increased for each 10-Gy increment in radiation dose to the lung, with the largest changes in regions of lung that received 50 to 60 Gy (ratio 0.72 [95% confidence interval 0.64-0.79], P<.001) compared with the 0- to 10-Gy region. For each increase in 10 Gy to the left lung, the lung perfusion ratio decreased by 0.06 (P<.001). Conclusions: In the assessment of 50 patients with node-positive breast cancer treated with RT in a prospective clinical trial, decreased lung perfusion by SPECT/CT was demonstrated. Our study allowed for quantification of lung perfusion defects in a prospective cohort of

  18. An evaluation of the feasibility of assessment of volume perfusion for the whole lung by 128-slice spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Haitao [Imaging Center of Taian Central Hospital, Taian, Shandong (China); Gao, Fei; Li, Ning; Liu, Cheng [Shandong Univ., Shandong Medical Imaging Research Inst., CT Room, Shandong (China)], e-mail: liucheng491025@sina.com

    2013-10-15

    Background: Lung perfusion based on dynamic scanning cannot provide a quantitative assessment of the whole lung because of the limited coverage of the current computed tomography (CT) detector designs. Purpose: To evaluate the feasibility of dynamic volume perfusion CT (VPCT) of the whole lung using a 128-slice CT for the quantitative assessment and visualization of pulmonary perfusion. Material and Methods: Imaging was performed in a control group of 17 subjects who had no signs of disturbance of pulmonary function or diffuse lung disease, and 15 patients (five patients with acute pulmonary embolism and 10 with emphysema) who constituted the abnormal lung group. Dynamic VPCT was performed in all subjects, and pulmonary blood flow (PBF), pulmonary blood volume (PBV), and mean transit time (MTT) were calculated from dynamic contrast images with a coverage of 20.7 cm. Regional and volumetric PBF, PBV, and MTT were statistically evaluated and comparisons were made between the normal and abnormal lung groups. Results: Regional PBF (94.2{+-}36.5, 161.8 {+-}29.6, 185.7 {+-}38.1 and 125.5 {+-}46.1, 161.9 {+-}31.4, 169.3 {+-}51.7), PBV (6.7 {+-}2.8, 10.9 {+-}3.0, 12.9 {+-}4.5 and 9.9 {+-}4.6, 10.3 {+-}2.9, 11.9 {+-}4.5), and MTT (5.8 {+-}2.4, 4.5 {+-}1.3, 4.7 {+-}2.1 and 5.6 {+-}2.3, 4.3 {+-}1.5, 4.9 {+-}1.5) demonstrated significant differences in the gravitational and isogravitational directions in the normal lung group (P < 0.05). The PBF (154.2 {+-}30.6 vs. 94.9 {+-}15.9) and PBV (11.1 {+-}4.0 vs. 6.6 {+-}1.7) by dynamic VPCT showed significant differences between normal and abnormal lungs (P < 0.05), notwithstanding the four large lungs that had coverage > 20.7 cm. Conclusion: Dynamic VPCT of the whole lung is feasible for the quantitative assessment of pulmonary perfusion by 128-slice CT, and may in future permit the evaluation of both morphological and functional features of the whole lung in a single examination.

  19. Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Kang, Yeon Koo; Ha, Seung Gyun [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); and others

    2017-06-15

    Until now, there was no single standardized regional segmentation method of planar lung perfusion scan. We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients. Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted. The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of % uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation. The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.

  20. CT Perfusion Characteristics Identify Metastatic Sites in Liver

    Directory of Open Access Journals (Sweden)

    Yuan Wang

    2015-01-01

    Full Text Available Tissue perfusion plays a critical role in oncology because growth and migration of cancerous cells require proliferation of new blood vessels through the process of tumor angiogenesis. Computed tomography (CT perfusion is an emerging functional imaging modality that measures tissue perfusion through dynamic CT scanning following intravenous administration of contrast medium. This noninvasive technique provides a quantitative basis for assessing tumor angiogenesis. CT perfusion has been utilized on a variety of organs including lung, prostate, liver, and brain, with promising results in cancer diagnosis, disease prognostication, prediction, and treatment monitoring. In this paper, we focus on assessing the extent to which CT perfusion characteristics can be used to discriminate liver metastases from neuroendocrine tumors from normal liver tissues. The neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow (BF, blood volume (BV, mean transit time (MTT, permeability (PS, and hepatic arterial fraction (HAF, for tumor and normal liver. The result reveals the potential of CT perfusion as a tool for constructing biomarkers from features of the hepatic vasculature for guiding cancer detection, prognostication, and treatment selection.

  1. Assessing tumor treatment response and prognosis in non-small cell lung cancer with perfusion CT

    International Nuclear Information System (INIS)

    Wang Jianwei; Wu Ning; Song Ying

    2010-01-01

    Objective: To prospectively investigate whether any of the perfusion parameters would predict early tumor response to chemotherapy and/or radiotherapy and prognosis in non-small cell lung cancer (NSCLC). Methods: In a prospective series, Perfusion CT were performed in 152 patients suspected lung cancer with 16-slice or 8-slice multislice CT. Contrast medium (50 ml) was injected at a rate of 4 ml/s with a power injector. The scanning delay was 10 seconds and the scanning time was 50 seconds. Among 152 patients, 123 patients were proved lung cancer by pathology. With the perfusion 3.0 software, the parameters including blood flow (BF), blood volume (BV), mean transit time (MTT) and capillary permeability surface area product (PS) were calculated. The perfusion image quality was evaluated on a 4-1eveal scale. The treatment response after chemotherapy and (or) radiotherapy was assessed with Response Evaluation Criteria in Solid Tumors (RECIST), and then the relationship between perfusion parameters with early tumor response to chemotherapy and (or) radiotherapy was evaluated. Student t test and Kaplan-Meier estimates were used for data analysis. Results: In 84 patients (68.3%), the perfusion image quality was staged level 2 (moderate) and level 3 (good). Among them, 35 patients with NSCLC were assessed with RECIST after chemotherapy and (or) radiotherapy. In these 35 patients, The BF of responders and nonresponders was (81.0 ± 33.6)and (56.3 ± 23.1) ml · min -1 ·100 g -1 , respectively, which was significantly different(t=2.393, P=0.023). The median PFS of low-BF group (BF ≤ 80 ml · min -1 · 100 g -1 ) and high-BF group (BF>80 ml · min -1 · 100 g -1 ) was 11.8 and 8.0 months respectively (P>0.05), and the median PFS of low-BV group (BF ≤ 6 ml/100 g -1 ) and high-BV group (BF>6 ml/100 g -1 ) was 9.2 and 8.0 months respectively(P>0.05), both of them were not significantly different. Conclusion: NSCLC in high perfusion are relatively sensitive to chemotherapy

  2. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. Preserving Functional Lung Using Perfusion Imaging and Intensity-Modulated Radiation Therapy for Advanced-Stage Non-Small Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shioyama, Yoshiyuki; Jang, Si Young; Liu, H. Helen; Guerrero, Thomas; Wang, Xuanmin; Gayed, Isis W.; Erwin, William D.; Liao, Zhongxing; Chang, Joe Y.; Jeter, Melenda; Yaremko, Brian P.; Borghero, Yerko O.; Cox, James D.; Komaki, Ritsuko; Mohan, Radhe

    2007-01-01

    Purpose: To assess quantitatively the impact of incorporating functional lung imaging into intensity-modulated radiation therapy planning for locally advanced non-small cell lung cancer (NSCLC). Methods and Materials: Sixteen patients with advanced-stage NSCLC who underwent radiotherapy were included in this study. Before radiotherapy, each patient underwent lung perfusion imaging with single-photon-emission computed tomography and X-ray computed tomography (SPECT-CT). The SPECT-CT was registered with simulation CT and was used to segment the 50- and 90-percentile hyperperfusion lung (F50 lung and F90 lung). Two IMRT plans were designed and compared in each patient: an anatomic plan using simulation CT alone and a functional plan using SPECT-CT in addition to the simulation CT. Dosimetric parameters of the two types of plans were compared in terms of tumor coverage and avoidance of normal tissues. Results: In incorporating perfusion information in IMRT planning, the median reductions in the mean doses to the F50 and F90 lung in the functional plan were 2.2 and 4.2 Gy, respectively, compared with those in the anatomic plans. The median reductions in the percentage of volume irradiated with >5 Gy, >10 Gy, and >20 Gy in the functional plans were 7.1%, 6.0%, and 5.1%, respectively, for F50 lung, and 11.7%, 12.0%, and 6.8%, respectively, for F90 lung. A greater degree of sparing of the functional lung was achieved for patients with large perfusion defects compared with those with relatively uniform perfusion distribution. Conclusion: Function-guided IMRT planning appears to be effective in preserving functional lung in locally advanced-stage NSCLC patients

  4. Perfusion abnormalities in congenital and neoplastic pulmonary disease: comparison of MR perfusion and multislice CT imaging

    International Nuclear Information System (INIS)

    Boll, Daniel T.; Lewin, Jonathan S.; Young, Philip; Gilkeson, Robert C.; Siwik, Ernest S.

    2005-01-01

    The aim of this work was to assess magnetic resonance (MR) perfusion patterns of chronic, nonembolic pulmonary diseases of congenital and neoplastic origin and to compare the findings with results obtained with pulmonary, contrast-enhanced multislice computed tomography (CT) imaging to prove that congenital and neoplastic pulmonary conditions require MR imaging over the pulmonary perfusion cycle to successfully and directly detect changes in lung perfusion patterns. Twenty-five patients underwent concurrent CT and MR evaluation of chronic pulmonary diseases of congenital (n=15) or neoplastic (n=10) origin. Analysis of MR perfusion and contrast-enhanced CT datasets was realized by defining pulmonary and vascular regions of interest in corresponding positions. MR perfusion calculated time-to-peak enhancement, maximal enhancement and the area under the perfusion curve. CT datasets provided pulmonary signal-to-noise ratio measurements. Vessel centerlines of bronchial arteries were determined. Underlying perfusion type, such as pulmonary arterial or systemic arterial supply, as well as regions with significant variations in perfusion were determined statistically. Analysis of the pulmonary perfusion pattern detected pulmonary arterial supply in 19 patients; six patients showed systemic arterial supply. In pulmonary arterial perfusion, MR and multislice CT imaging consistently detected the perfusion type and regions with altered perfusion patterns. In bronchial arterial supply, MR perfusion and CT imaging showed significant perfusion differences. Patients with bronchial arterial supply had bronchial arteries ranging from 2.0 to 3.6 mm compared with submillimeter diameters in pulmonary arterial perfusion. Dynamic MR imaging of congenital and neoplastic pulmonary conditions allowed characterization of the pulmonary perfusion type. CT imaging suggested the presence of systemic arterial perfusion by visualizing hypertrophied bronchial arteries. (orig.)

  5. Automatic delineation of functional lung volumes with 68Ga-ventilation/perfusion PET/CT.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Callahan, Jason; Claudic, Yannis; Bourhis, David; Steinfort, Daniel P; Hicks, Rodney J; Hofman, Michael S

    2017-10-10

    Functional volumes computed from 68 Ga-ventilation/perfusion (V/Q) PET/CT, which we have shown to correlate with pulmonary function test parameters (PFTs), have potential diagnostic utility in a variety of clinical applications, including radiotherapy planning. An automatic segmentation method would facilitate delineation of such volumes. The aim of this study was to develop an automated threshold-based approach to delineate functional volumes that best correlates with manual delineation. Thirty lung cancer patients undergoing both V/Q PET/CT and PFTs were analyzed. Images were acquired following inhalation of Galligas and, subsequently, intravenous administration of 68 Ga-macroaggreted-albumin (MAA). Using visually defined manual contours as the reference standard, various cutoff values, expressed as a percentage of the maximal pixel value, were applied. The average volume difference and Dice similarity coefficient (DSC) were calculated, measuring the similarity of the automatic segmentation and the reference standard. Pearson's correlation was also calculated to compare automated volumes with manual volumes, and automated volumes optimized to PFT indices. For ventilation volumes, mean volume difference was lowest (- 0.4%) using a 15%max threshold with Pearson's coefficient of 0.71. Applying this cutoff, median DSC was 0.93 (0.87-0.95). Nevertheless, limits of agreement in volume differences were large (- 31.0 and 30.2%) with differences ranging from - 40.4 to + 33.0%. For perfusion volumes, mean volume difference was lowest and Pearson's coefficient was highest using a 15%max threshold (3.3% and 0.81, respectively). Applying this cutoff, median DSC was 0.93 (0.88-0.93). Nevertheless, limits of agreement were again large (- 21.1 and 27.8%) with volume differences ranging from - 18.6 to + 35.5%. Using the 15%max threshold, moderate correlation was demonstrated with FEV1/FVC (r = 0.48 and r = 0.46 for ventilation and perfusion images, respectively

  6. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Iwanaga, Hideyuki; Hayashi, Noriko; Seto, Akiko; Matsunaga, Naofumi

    2008-01-01

    Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P<0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P<0.05). DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease. (author)

  7. Feasibility of perfusion CT technique integrated into conventional {sup 18}FDG/PET-CT studies in lung cancer patients: clinical staging and functional information in a single study

    Energy Technology Data Exchange (ETDEWEB)

    Ippolito, Davide; Capraro, Cristina; Sironi, Sandro [University of Milano-Bicocca, School of Medicine, Milan (Italy); University of Milano-Bicocca, Department of Diagnostic Radiology, H.S. Gerardo Monza, Via Pergolesi 11, Monza, Milan (Italy); Guerra, Luca [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); De Ponti, Elena [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Medical Physics, Monza (Italy); Messa, Cristina [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); Tecnomed Foundation, University of Milano-Bicocca, Institute for Bioimaging and Molecular Physiology, National Research Council, Milan (Italy)

    2013-02-15

    To assess the additional functional vascular information and the relationship between perfusion measurements and glucose metabolism (SUVmax) obtained by including a perfusion CT study in a whole-body contrast-enhanced PET/CT protocol in primary lung cancer lesions. Enrolled in this prospective study were 34 consecutive patients with a biopsy-proven diagnosis of lung cancer who were referred for contrast-enhanced PET/CT staging. This prospective study was approved by our institutional review board, and informed consent was obtained from all patients. Perfusion CT was performed with the following parameters: 80 kV, 200 mAs, 30 scans during intravenous injection of 50 ml contrast agent, flow rate 5 ml/s. Another bolus of contrast medium (3.5 ml/s, 80 ml, 60-s delay) was administered to ensure a full diagnostic contrast-enhanced CT scan for clinical staging. The perfusion CT data were used to calculate a range of tumour vascularity parameters (blood flow, blood volume and mean transit time), and tumour FDG uptake (SUVmax) was used as a metabolic indicator. Quantitative and functional parameters were compared and in relation to location, histology and tumour size. The nonparametric Kruskal-Wallis rank sum test was used for statistical analysis. A cut-off value of 3 cm was used according to the TNM classification to discriminate between T1 and T2 tumours (i.e. T1b vs. T2a). There were significant perfusion differences (lower blood volumes and higher mean transit time) between tumours with diameter >30 mm and tumours with diameter <30 mm (p < 0.05; blood volume 5.6 vs. 7.1 ml/100 g, mean transit time 8.6 vs. 3.9 s, respectively). Also there was a trend for blood flow to be lower in larger lesions (p < 0.053; blood flow 153.1 vs. 98.3 ml/100 g tissue/min). Significant inverse correlations (linear regression) were found between blood volume and SUVmax in tumours with diameter >30 mm in diameter. Perfusion CT combined with PET/CT is feasible technique that may provide

  8. Loss of lung function after chemo-radiotherapy for NSCLC measured by perfusion SPECT/CT: Correlation with radiation dose and clinical morbidity

    DEFF Research Database (Denmark)

    Farr, Katherina P; Møller, Ditte S; Khalil, Azza A

    2015-01-01

    BACKGROUND: The purpose of the study was to assess dose and time dependence of radiotherapy (RT)-induced changes in regional lung function measured with single photon emission computed tomography (SPECT) of the lung and relate these changes to the symptomatic endpoint of radiation pneumonitis (RP......) in patients treated for non-small cell lung cancer (NSCLC). MATERIAL AND METHODS: NSCLC patients scheduled to receive curative RT of minimum 60 Gy were included prospectively in the study. Lung perfusion SPECT/CT was performed before and three months after RT. Reconstructed SPECT/CT data were registered...

  9. Accuracy and Utility of Deformable Image Registration in 68Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Hofman, Michael S.; Hicks, Rodney J.; Callahan, Jason; Kron, Tomas; MacManus, Michael P.; Ball, David L.; Jackson, Price; Siva, Shankar

    2015-01-01

    Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: 68 Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions

  10. High-resolution pulmonary ventilation and perfusion PET/CT allows for functionally adapted intensity modulated radiotherapy in lung cancer

    International Nuclear Information System (INIS)

    Siva, Shankar; Thomas, Roshini; Callahan, Jason; Hardcastle, Nicholas; Pham, Daniel; Kron, Tomas; Hicks, Rodney J.; MacManus, Michael P.; Ball, David L.; Hofman, Michael S.

    2015-01-01

    Background and purpose: To assess the utility of functional lung avoidance using IMRT informed by four-dimensional (4D) ventilation/perfusion (V/Q) PET/CT. Materials and methods: In a prospective clinical trial, patients with non-small cell lung cancer (NSCLC) underwent 4D-V/Q PET/CT scanning before 60 Gy of definitive chemoradiation. Both “highly perfused” (HPLung) and “highly ventilated” (HVLung) lung volumes were delineated using a 70th centile SUV threshold, and a “ventilated lung volume” (VLung) was created using a 50th centile SUV threshold. For each patient four IMRT plans were created, optimised to the anatomical lung, HPLung, HVLung and VLung volumes, respectively. Improvements in functional dose volumetrics when optimising to functional volumes were assessed using mean lung dose (MLD), V5, V10, V20, V30, V40, V50 and V60 parameters. Results: The study cohort consisted of 20 patients with 80 IMRT plans. Plans optimised to HPLung resulted in a significant reduction of functional MLD by a mean of 13.0% (1.7 Gy), p = 0.02. Functional V5, V10 and V20 were improved by 13.2%, 7.3% and 3.8% respectively (p-values < 0.04). There was no significant sparing of dose to functional lung when adapting to VLung or HVLung. Plan quality was highly consistent with a mean PTV D95 and D5 ranging from 60.8 Gy to 61.0 Gy and 63.4 Gy to 64.5 Gy, respectively, and mean conformity and heterogeneity index ranging from 1.11 to 1.17 and 0.94 to 0.95, respectively. Conclusion: IMRT plans adapted to perfused but not ventilated lung on 4D-V/Q PET/CT allowed for reduced dose to functional lung whilst maintaining consistent plan quality

  11. Lung perfusion characteristics in pulmonary arterial hypertension (PAH) and peripheral forms of chronic thromboembolic pulmonary hypertension (pCTEPH): Dual-energy CT experience in 31 patients

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, Jessica; Khung, Suonita; Remy, Jacques; Remy-Jardin, Martine [Hospital Calmette (EA 2694), Department of Thoracic Imaging, Lille (France); Duhamel, Alain [University Lille, CHU Lille, Department of Biostatistics, Lille (France); Hossein-Foucher, Claude; Bellevre, Dimitri [University Lille, CHU Lille, Department of Nuclear Medicine, Hospital Salengro, Lille (France); Lamblin, Nicolas [University Lille, CHU Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2017-04-15

    To compare lung perfusion in PAH and pCTEPH on dual-energy CT (DECT) examinations. Thirty-one patients with PAH (group 1; n = 19) and pCTEPH (group 2; n = 12) underwent a dual-energy chest CTA with reconstruction of diagnostic and perfusion images. Perfusion alterations were analysed at a segmental level. V/Q scintigraphy was available in 22 patients (group 1: 13/19; group 2: 9/12). CT perfusion was abnormal in 52.6 % of group 1 patients and in 100 % of group 2 patients (p = 0.0051). The patterns of perfusion alteration significantly differed between the two groups (p < 0.0001): (1) in group 1, 96.6 % of segments with abnormal perfusion showed patchy defects; (2) in group 2, the most frequent abnormalities consisted of patchy (58.5 %) and PE-type (37.5 %) defects. Paired comparison of CT perfusion and scintigraphy showed concordant findings in 76.9 % of group 1 (10/13) and 100 % of group 2 (9/9) patients, with a predominant or an exclusive patchy pattern in group 1 and a mixed pattern of abnormalities in group 2. Lung perfusion alterations at DECT are less frequent and more homogeneous in PAH than in pCTEPH, with a high level of concordant findings with V/Q scintigraphy. (orig.)

  12. Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas, E-mail: nick.hardcastle@gmail.com [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong (Australia); Hofman, Michael S. [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Hicks, Rodney J. [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Department of Medicine, University of Melbourne, Melbourne (Australia); Callahan, Jason [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Kron, Tomas [Department of Medical Imaging and Radiation Sciences, Monash University, Clayton (Australia); The Sir Peter MacCallum Department of Oncology, Melbourne University, Victoria (Australia); MacManus, Michael P.; Ball, David L. [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); The Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne (Australia); Jackson, Price [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Siva, Shankar [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia)

    2015-09-01

    Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration

  13. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Park, Sang Hyub [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  14. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-01-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  15. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy.

    Science.gov (United States)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-11-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy.

  16. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  17. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  18. Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT.

    Science.gov (United States)

    Cheimariotis, Grigorios-Aris; Al-Mashat, Mariam; Haris, Kostas; Aletras, Anthony H; Jögi, Jonas; Bajc, Marika; Maglaveras, Nicolaos; Heiberg, Einar

    2018-02-01

    Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with reference computed tomography (CT) volumes. A total of 77 subjects (69 patients with obstructive lung disease, and 8 subjects without apparent perfusion of ventilation loss) performed low-dose CT followed by ventilation/perfusion (V/P) SPECT examination in a hybrid gamma camera system. In the training phase, lung shapes from the 57 anatomical low-dose CT images were used to construct two active shape models (right lung and left lung) which were then used for image segmentation. The algorithm was validated in 20 patients, comparing its results to reference delineation of corresponding CT images, and by comparing automatic segmentation to manual delineations in SPECT images. The Dice coefficient between automatic SPECT delineations and manual SPECT delineations were 0.83 ± 0.04% for the right and 0.82 ± 0.05% for the left lung. There was statistically significant difference between reference volumes from CT and automatic delineations for the right (R = 0.53, p = 0.02) and left lung (R = 0.69, p automatic quantification of wide range of measurements.

  19. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    International Nuclear Information System (INIS)

    Siva, Shankar; Hardcastle, Nicholas; Kron, Tomas; Bressel, Mathias; Callahan, Jason; MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki; Hicks, Rodney J.; Steinfort, Daniel; Ball, David L.; Hofman, Michael S.

    2015-01-01

    Purpose: To investigate 68 Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r 2 =0.99, P<.01), with ventilation strongly negatively linear (r 2 =0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET/CT imaging. These

  20. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    Energy Technology Data Exchange (ETDEWEB)

    Siva, Shankar, E-mail: shankar.siva@petermac.org [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville (Australia); Hardcastle, Nicholas [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong (Australia); Kron, Tomas [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Bressel, Mathias [Department of Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, East Melbourne (Australia); Callahan, Jason [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Hicks, Rodney J. [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Medicine, University of Melbourne, Parkville (Australia); Steinfort, Daniel [Department of Medicine, University of Melbourne, Parkville (Australia); Department of Cancer Medicine, Peter MacCallum Cancer Centre, East Melbourne (Australia); Ball, David L. [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Hofman, Michael S. [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Medicine, University of Melbourne, Parkville (Australia)

    2015-10-01

    Purpose: To investigate {sup 68}Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r{sup 2}=0.99, P<.01), with ventilation strongly negatively linear (r{sup 2}=0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET/CT

  1. Estimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Horger, Marius; Buchgeister, Markus; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Schulze, Maximilian; Tsiflikas, Ilias; Claussen, Claus D.; Heuschmid, Martin [University Hospital Tuebingen, Tuebingen (Germany)

    2010-10-15

    We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D Perfusion-CT. Phantom measurements were performed on a 128-slice single source scanner in adaptive 4D-spiral-mode with bidirectional table movement and a total scan range of 69 mm over a time period of nearly 120 seconds (26 scans). Perfusion measurements were simulated for the lung, liver, and pelvis under the following conditions: lung (80 kV, 60 mAs), liver (80 kV/80 mAs and 80 kV/120 mAs), pelvis (100 kV/80 mAs and 100 kV/120 mAs). Depending on gender, the evaluated body region and scan protocol, an effective whole-body dose between 2.9-12.2 mSv, was determined. The radiation exposure administered to gender-specific organs like the female breast tissue (lung perfusion) or to the ovaries (pelvic perfusion) led to an increase in the female specific dose by 86% and 100% in perfusion scans of the lung and the pelvis, respectively. Due to a significant radiation dose of 4D-perfusion-CT protocols, the responsible use of this new promising technique is mandatory. Gender- and organ-specific differences should be considered for indication and planning of tumor perfusion scans

  2. Dynamic Contrast-Enhanced Perfusion Area-Detector CT: Preliminary Comparison of Diagnostic Performance for N Stage Assessment With FDG PET/CT in Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Yoshikawa, Takeshi

    2017-11-01

    The objective of our study was to directly compare the capability of dynamic first-pass contrast-enhanced (CE) perfusion area-detector CT (ADCT) and FDG PET/CT for differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with non-small cell lung carcinoma (NSCLC). Seventy-seven consecutive patients, 45 men (mean age ± SD, 70.4 ± 5.9 years) and 32 women (71.2 ± 7.7 years), underwent dynamic first-pass CE-perfusion ADCT at two or three different positions for covering the entire thorax, FDG PET/CT, surgical treatment, and pathologic examination. From all ADCT data for each of the subjects, a whole-chest perfusion map was computationally generated using the dual- and single-input maximum slope and Patlak plot methods. For quantitative N stage assessment, perfusion parameters and the maximum standardized uptake value (SUV max ) for each lymph node were determined by measuring the relevant ROI. ROC curve analyses were performed for comparing the diagnostic capability of each of the methods on a per-node basis. N stages evaluated by each of the indexes were then statistically compared with the final pathologic diagnosis by means of chi-square and kappa statistics. The area under the ROC curve (A z ) values of systemic arterial perfusion (A z = 0.89), permeability surface (A z = 0.78), and SUV max (A z = 0.85) were significantly larger than the A z values of total perfusion (A z = 0.70, p Dynamic first-pass CE-perfusion ADCT is as useful as FDG PET/CT for the differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with NSCLC.

  3. Framework for radiation pneumonitis risk stratification based on anatomic and perfused lung dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Dhami, Gurleen; Zeng, Jing; Patel, Shilpen A.; Rengan, Ramesh [University of Washington School of Medicine, Department of Radiation Oncology, Seattle, WA (United States); Vesselle, Hubert J.; Kinahan, Paul E.; Miyaoka, Robert S. [University of Washington School of Medicine, Department of Radiology, Seattle, WA (United States); Bowen, Stephen R. [University of Washington School of Medicine, Department of Radiation Oncology, Seattle, WA (United States); University of Washington School of Medicine, Department of Radiology, Seattle, WA (United States)

    2017-05-15

    To design and apply a framework for predicting symptomatic radiation pneumonitis in patients undergoing thoracic radiation, using both pretreatment anatomic and perfused lung dose-volume parameters. Radiation treatment planning CT scans were coregistered with pretreatment [{sup 99m}Tc]MAA perfusion SPECT/CT scans of 20 patients who underwent definitive thoracic radiation. Clinical radiation pneumonitis was defined as grade ≥ 2 (CTCAE v4 grading system). Anatomic lung dose-volume parameters were collected from the treatment planning scans. Perfusion dose-volume parameters were calculated from pretreatment SPECT/CT scans. Equivalent doses in 2 Gy per fraction were calculated in the lung to account for differences in treatment regimens and spatial variations in lung dose (EQD2{sub lung}). Anatomic lung dosimetric parameters (MLD) and functional lung dosimetric parameters (pMLD{sub 70%}) were identified as candidate predictors of grade ≥ 2 radiation pneumonitis (AUC > 0.93, p < 0.01). Pairing of an anatomic and functional dosimetric parameter (e.g., MLD and pMLD{sub 70%}) may further improve prediction accuracy. Not all individuals with high anatomic lung dose (MLD > 13.6 GyEQD2{sub lung}, 19.3 Gy for patients receiving 60 Gy in 30 fractions) developed radiation pneumonitis, but all individuals who also had high mean dose to perfused lung (pMLD{sub 70%} > 13.3 GyEQD2) developed radiation pneumonitis. The preliminary application of this framework revealed differences between anatomic and perfused lung dosimetry in this limited patient cohort. The addition of perfused lung parameters may help risk stratify patients for radiation pneumonitis, especially in treatment plans with high anatomic mean lung dose. Further investigations are warranted. (orig.) [German] Erstellung und Anwendung eines Rahmenwerks zur Vorhersage symptomatischer Strahlenpneumonitis bei Patienten mit einer Thorax-Bestrahlung anhand anatomischer und perfundierter Lungendosis-Volumen-Parameter in der

  4. Estimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity

    Science.gov (United States)

    Horger, Marius; Buchgeister, Markus; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Schulze, Maximilian; Tsiflikas, Ilias; Claussen, Claus D.; Heuschmid, Martin

    2010-01-01

    Objective We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. Materials and Methods An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D-Perfusion-CT. Phantom measurements were performed on a 128-slice single-source scanner in adaptive 4D-spiral-mode with bidirectional table movement and a total scan range of 69 mm over a time period of nearly 120 seconds (26 scans). Perfusion measurements were simulated for the lung, liver, and pelvis under the following conditions: lung (80 kV, 60 mAs), liver (80 kV/80 mAs and 80 kV/120 mAs), pelvis (100 kV/80 mAs and 100 kV/120 mAs). Results Depending on gender, the evaluated body region and scan protocol, an effective whole-body dose between 2.9-12.2 mSv, was determined. The radiation exposure administered to gender-specific organs like the female breast tissue (lung perfusion) or to the ovaries (pelvic perfusion) led to an increase in the female specific dose by 86% and 100% in perfusion scans of the lung and the pelvis, respectively. Conclusion Due to a significant radiation dose of 4D-perfusion-CT protocols, the responsible use of this new promising technique is mandatory. Gender- and organ-specific differences should be considered for indication and planning of tumor perfusion scans. PMID:20808699

  5. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  6. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  7. Assessment of the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level in patients with emphysema

    International Nuclear Information System (INIS)

    Ley-Zaporozhan, Julia; Ley, Sebastian; Eberhardt, Ralf; Weinheimer, Oliver; Fink, Christian; Puderbach, Michael; Eichinger, Monika; Herth, Felix; Kauczor, Hans-Ulrich

    2007-01-01

    Purpose: To assess the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level using CT and MRI in patients with emphysema. Material and methods: Forty-five patients with severe emphysema (GOLD III and IV) underwent inspiratory 3D-HRCT and contrast-enhanced MR-perfusion (1.5T; 3.5 mm x 1.9 mm x 4 mm). 3D-HRCT data was analyzed using a software for detection and visualization of emphysema. Emphysema was categorized in four clusters with different volumes and presented as overlay on the CT. CT and lung perfusion were visually analyzed for three lobes on each side using a four-point-score to grade the abnormalities on CT (1: predominantly small emphysema-clusters to 4: >75% large emphysema-clusters) and MRI (1: normal perfusion to 4: no perfusion). Results: A total of 270 lobes were evaluated. At CT, the score was 1 for 9 lobes, 2 for 43, 3 for 77, and 4 for 141 lobes. At MRI, the score was 1 for 13 lobes, 2 for 45, 3 for 92, and 4 for 120 lobes. Matching of lung parenchymal destruction and reduced perfusion was found in 213 lobes (weighted kappa = 0.8). The score was higher on CT in 44, and higher on MRI in 13 lobes. Conclusion: 3D-HRCT and 3D MR-perfusion show a high lobar agreement between parenchymal destruction and reduction of perfusion in patients with severe emphysema

  8. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    Science.gov (United States)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between

  9. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  10. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  11. Correlation between [{sup 18}F]FDG PET/CT and volume perfusion CT in primary tumours and mediastinal lymph nodes of non-small-cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sauter, Alexander W.; Spira, Daniel; Schulze, Maximilian; Pfannenberg, Christina; Claussen, Claus D.; Horger, Marius S. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Hetzel, Juergen [Eberhard Karls University, Department of Oncology, Hematology, Immunology, Rheumatology and Pulmonology, Tuebingen (Germany); Reimold, Matthias [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany); Klotz, Ernst [Siemens Healthcare, Computed Tomography, Forchheim (Germany)

    2013-05-15

    The aim of this study was to investigate correlations between glucose metabolism as determined by [{sup 18}F]FDG PET/CT and tumour perfusion as quantified by volume perfusion CT in primary tumours and mediastinal lymph nodes (MLN) of patients with non-small-cell lung cancer (NSCLC). Enrolled in the study were 17 patients with NSCLC. [{sup 18}F]FDG uptake was quantified in terms of SUV{sub max} and SUV{sub avg}. Blood flow (BF), blood volume (BV) and flow extraction product (K{sup trans}) were determined as perfusion parameters. The correlations between the perfusion parameters and [{sup 18}F]FDG uptake values were subsequently evaluated. For the primary tumours, no correlations were found between perfusion parameters and [{sup 18}F]FDG uptake. In MLN, there were negative correlations between BF and SUV{sub avg} (r = -0.383), BV and SUV{sub avg} (r = -0.406), and BV and SUV{sub max} (r = -0.377), but not between BF and SUV{sub max}, K{sup trans} and SUV{sub avg}, or K{sup trans} and SUV{sub max}. Additionally, in MLN with SUV{sub max} >2.5 there were negative correlations between BF and SUV{sub avg} (r = -0.510), BV and SUV{sub avg} (r = -0.390), BF and SUV{sub max} (r = -0.536), as well as BV and SUV{sub max} (r = -0.346). Perfusion and glucose metabolism seemed to be uncoupled in large primary tumours, but an inverse correlation was observed in MLN. This information may help improve therapy planning and response evaluation. (orig.)

  12. Perfusion- and pattern-based quantitative CT indexes using contrast-enhanced dual-energy computed tomography in diffuse interstitial lung disease: relationships with physiologic impairment and prediction of prognosis

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jung Won [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Bae, Jang Pyo; Kim, Namkug; Chang, Yongjun; Seo, Joon Beom [University of Ulsan College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Lee, Ho Yun; Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Chung, Man Pyo; Park, Hye Yun [Sungkyunkwan University School of Medicine, Department of Pulmonology, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-05-15

    To evaluate automated texture-based segmentation of dual-energy CT (DECT) images in diffuse interstitial lung disease (DILD) patients and prognostic stratification by overlapping morphologic and perfusion information of total lung. Suspected DILD patients scheduled for surgical biopsy were prospectively included. Texture patterns included ground-glass opacity (GGO), reticulation and consolidation. Pattern- and perfusion-based CT measurements were assessed to extract quantitative parameters. Accuracy of texture-based segmentation was analysed. Correlations between CT measurements and pulmonary function test or 6-minute walk test (6MWT) were calculated. Parameters of idiopathic pulmonary fibrosis/usual interstitial pneumonia (IPF/UIP) and non-IPF/UIP were compared. Survival analysis was performed. Overall accuracy was 90.47 % for whole lung segmentation. Correlations between mean iodine values of total lung, 50-97.5th (%) attenuation and forced vital capacity or 6MWT were significant. Volume of GGO, reticulation and consolidation had significant correlation with DLco or SpO{sub 2} on 6MWT. Significant differences were noted between IPF/UIP and non-IPF/UIP in 6MWT distance, mean iodine value of total lung, 25-75th (%) attenuation and entropy. IPF/UIP diagnosis, GGO ratio, DILD extent, 25-75th (%) attenuation and SpO{sub 2} on 6MWT showed significant correlations with survival. DECT combined with pattern analysis is useful for analysing DILD and predicting survival by provision of morphology and enhancement. (orig.)

  13. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  14. Dynamic volume perfusion CT in patients with lung cancer: Baseline perfusion characteristics of different histological subtypes

    International Nuclear Information System (INIS)

    Shi, Jingyun; Schmid-Bindert, Gerald; Fink, Christian; Sudarski, Sonja; Apfaltrer, Paul; Pilz, Lothar R.; Liu, Bo; Haberland, Ulrike; Klotz, Ernst

    2013-01-01

    Objective: To evaluate dynamic volume perfusion CT (dVPCT) tumor baseline characteristics of three different subtypes of lung cancer in untreated patients. Materials and methods: 173 consecutive patients (131 men, 42 women; mean age 61 ± 10 years) with newly diagnosed lung cancer underwent dVPCT prior to biopsy. Tumor permeability, blood flow (BF), blood volume (BV) and mean transit time (MTT) were quantitatively assessed as well as tumor diameter and volume. Tumor subtypes were histologically determined and compared concerning their dVPCT results. dVPCT results were correlated to tumor diameter and volume. Results: Histology revealed adenocarcinoma in 88, squamous cell carcinoma in 54 and small cell lung cancer (SCLC) in 31 patients. Tumor permeability was significantly differing between adenocarcinoma, squamous cell carcinoma and SCLC (all p < 0.05). Tumor BF and BV were higher in adenocarcinomathan in SCLC (p = 0.001 and p = 0.0002 respectively). BV was also higher in squamous cell carcinoma compared to SCLC (p = 0.01). MTT was not differing between tumor subtypes. Regarding all tumors, tumor diameter did not correlate with any of the dVPCT parameters, whereas tumor volume was negatively associated with permeability, BF and BV (r = −0.22, −0.24, −0.24, all p < 0.05). In squamous cell carcinoma, tumor diameter und volume correlated with BV (r = 0.53 and r = −0.40, all p < 0.05). In SCLC, tumor diameter und volume correlated with MTT (r = 0.46 and r = 0.39, all p < 0.05). In adenocarcinoma, no association between morphological and functional tumor characteristics was observed. Conclusions: dVPCT parameters are only partially related to tumor diameter and volume and are significantly differing between lung cancer subtypes

  15. Differentiation of malignant and benign pulmonary nodules with first-pass dual-input perfusion CT

    International Nuclear Information System (INIS)

    Yuan, Xiaodong; Quan, Changbin; Cao, Jianxia; Ao, Guokun; Tian, Yuan; Li, Hong; Zhang, Jing

    2013-01-01

    To assess diagnostic performance of dual-input CT perfusion for distinguishing malignant from benign solitary pulmonary nodules (SPNs). Fifty-six consecutive subjects with SPNs underwent contrast-enhanced 320-row multidetector dynamic volume CT. The dual-input maximum slope CT perfusion analysis was employed to calculate the pulmonary flow (PF), bronchial flow (BF), and perfusion index (PI,=PF/(PF+BF)). Differences in perfusion parameters between malignant and benign tumours were assessed with histopathological diagnosis as the gold standard. Diagnostic value of the perfusion parameters was calculated using the receiver-operating characteristic (ROC) curve analysis. Amongst 56 SPNs, statistically significant differences in all three perfusion parameters were revealed between malignant and benign tumours. The PI demonstrated the biggest difference between malignancy and benignancy: 0.30 ± 0.07 vs. 0.51 ± 0.13, P < 0.001. The area under the PI ROC curve was 0.92, the largest of the three perfusion parameters, producing a sensitivity of 0.95, specificity of 0.83, positive likelihood ratio (+LR) of 5.59, and negative likelihood ratio (-LR) of 0.06 in identifying malignancy. The PI derived from the dual-input maximum slope CT perfusion analysis is a valuable biomarker for identifying malignancy in SPNs. PI may be potentially useful for lung cancer treatment planning and forecasting the therapeutic effect of radiotherapy treatment. (orig.)

  16. Factors affecting the lung perfused blood volume in patients with intrapulmonary clots after anti-coagulation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa, E-mail: radokada@yamaguchi-u.ac.jp [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Masuda, Yu [4th Grade of 6-year Medicine Doctor Program, Department of Medicine, Yamaguchi University Faculty of Medicine and Health Sciences 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Nakashima, Yoshiteru [Department of Radiology, Yamaguchi Grand Medical Center, Oosaki 77, Hofu, Yamaguchi 747-8511 (Japan); Nomura, Takafumi; Nakao, Sei [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Suga, Kazuyoshi [Department of Radiology, St Hills Hospital, Imamurakita 3-7-18, Ube, Yamaguchi 755-0155 (Japan); Kido, Shoji [Computer-aided Diagnosis and Biomedical Imaging Research Biomedical Engineering, Applied Medical Engineering Science Graduate School of Medicine, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi 755-8611 (Japan); Matsunaga, Naofumi [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan)

    2015-08-15

    Highlights: • Dual-energy CT can provide morphological and functional lung images in the same examination. • The subsequent dual-energy CT demonstrates the increased whole lung perfused blood volume (V{sub 120}) despite the residual intrapulmonary clots after treatment in one examination. • The increased whole lung perfusion (V{sub 120}) and a decreased low perfusion volume (V{sub 5}) result in the improvement in the low perfusion rate (%V{sub 5}) in the patients with acute pulmonary embolism after treatment. - Abstract: Objectives: Factors affecting the improvement in the lung perfused blood volume (LPBV) were evaluated based on the presence of intrapulmonary clots (IPCs) after anti-coagulation therapy using 64-slice dual-energy CT. Materials and methods: 96 patients exhibiting venous thromboembolism underwent initial and repeated LPBV examinations between December 2008 and July 2014. Fifteen patients were excluded due to pulmonary comorbidities, and a total of 81 patients were included in this study. Acute pulmonary embolism (PE) was diagnosed in 46 of the patients (56.7%). LPBV images were three-dimensionally reconstructed with two threshold ranges: 1–120 HU (V{sub 120}) and 1–5 HU (V{sub 5}), and the relative value of V{sub 5} per V{sub 120} expressed as %V{sub 5}. These values were subsequently compared with indicators of the severity of PE, such as the D-dimer level, heart rate and CT measurements. This study was approved by the local ethics committee. Results: In patients with IPCs, the D-dimer, V{sub 5} and %V{sub 5}values were significantly larger (p ≤ 0.01) in the initial LPBV, although these differences disappeared in subsequent LPBV after treatment. The right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio and %V{sub 5} values were also significantly reduced, whereas the V{sub 5} value did not significantly decrease (p = 0.07), but V{sub 120} value significantly increased (p < 0.001) after treatment. However, in

  17. Pulmonary function-morphologic relationships assessed by SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2012-01-01

    Pulmonary single photon emission computed tomography-computed tomography (SPECT-CT) fusion images provide objective and comprehensive assessment of pulmonary function and morphology relationships at cross-sectional lungs. This article reviewed the noteworthy findings of lung pathophysiology in wide-spectral lung disorders, which have been revealed on SPECT-CT fusion images in 8 years of experience. The fusion images confirmed the fundamental pathophysiologic appearance of lung low CT attenuation caused by airway obstruction-induced hypoxic vasoconstriction and that caused by direct pulmonary arterial obstruction as in acute pulmonary thromboembolism (PTE). The fusion images showed better correlation of lung perfusion distribution with lung CT attenuation changes at lung mosaic CT attenuation (MCA) compared with regional ventilation in the wide-spectral lung disorders, indicating that lung heterogeneous perfusion distribution may be a dominant mechanism of MCA on CT. SPECT-CT angiography fusion images revealed occasional dissociation between lung perfusion defects and intravascular clots in acute PTE, indicating the importance of assessment of actual effect of intravascular colts on peripheral lung perfusion. Perfusion SPECT-CT fusion images revealed the characteristic and preferential location of pulmonary infarction in acute PTE. The fusion images showed occasional unexpected perfusion defects in normal lung areas on CT in chronic obstructive pulmonary diseases and interstitial lung diseases, indicating the ability of perfusion SPECT superior to CT for detection of mild lesions in these disorders. The fusion images showed frequent ''steal phenomenon''-induced perfusion defects extending to the surrounding normal lung of arteriovenous fistulas and those at normal lungs on CT in hepatopulmonary syndrome. Comprehensive assessment of lung function-CT morphology on fusion images will lead to more profound understanding of lung pathophysiology in wide-spectral lung

  18. Dual-energy perfusion-CT of pancreatic adenocarcinoma

    International Nuclear Information System (INIS)

    Klauß, M.; Stiller, W.; Pahn, G.; Fritz, F.; Kieser, M.; Werner, J.; Kauczor, H.U.; Grenacher, L.

    2013-01-01

    Purpose: To evaluate the feasibility of dual-energy CT (DECT)-perfusion of pancreatic carcinomas for assessing the differences in perfusion, permeability and blood volume of healthy pancreatic tissue and histopathologically confirmed solid pancreatic carcinoma. Materials and methods: 24 patients with histologically proven pancreatic carcinoma were examined prospectively with a 64-slice dual source CT using a dynamic sequence of 34 dual-energy (DE) acquisitions every 1.5 s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). 80 kV p , 140 kV p , and weighted average (linearly blended M0.3) 120 kV p -equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool (Body-PCT, Siemens Medical Solutions, Erlangen, Germany) for estimating perfusion, permeability, and blood volume values. Color-coded parameter maps were generated. Results: In all 24 patients dual-energy CT-perfusion was. All carcinomas could be identified in the color-coded perfusion maps. Calculated perfusion, permeability and blood volume values were significantly lower in pancreatic carcinomas compared to healthy pancreatic tissue. Weighted average 120 kV p -equivalent perfusion-, permeability- and blood volume-values determined from DE image data were 0.27 ± 0.04 min −1 vs. 0.91 ± 0.04 min −1 (p −1 vs. 0.67 ± 0.05 *0.5 min −1 (p = 0.06) and 0.49 ± 0.07 min −1 vs. 1.28 ± 0.11 min −1 (p p the standard deviations of the kV p 120 kV p -equivalent values were manifestly smaller. Conclusion: Dual-energy CT-perfusion of the pancreas is feasible. The use of DECT improves the accuracy of CT-perfusion of the pancreas by fully exploiting the advantages of enhanced iodine contrast at 80 kV p in combination with the noise reduction at 140 kV p . Therefore using dual-energy perfusion data could improve the delineation of pancreatic carcinomas

  19. Quantative pre-surgical lung function estimation with SPECT/CT

    International Nuclear Information System (INIS)

    Bailey, Dale L.; Timmins, Sophi; Harris, Benjamin E.; Bailey, Elizabeth A.; Roach, Paul J.; Willowson, Kathy P.

    2009-01-01

    Full text: Objectives: To develop methodology to predict lobar lung function based on SPECT/CT ventilation 6 k perfusion (V/Q) scanning in candidates for lobectomy for lung cancer. This combines two development areas from our group: quantitative SPECT based on CT-derived corrections for scattering and attenuation of photons, and SPECT V/Q scanning with lobar segmentation from CT Six patients underwent baseline pulmonary function testing (PFT) including spirometry, measurement of DLCO and cardio-pulmonary exercise testing. A SPECT/CT V/Q scan was acquired at baseline. Using in-house software each lobe was anatomically defined using CT to provide lobar ROIs which could be applied to the SPECT data. From these, individual lobar contribution to overall function was calculated from counts within the lobe and post-operative FEVl, DLCO and V02 peak were predicted. This was compared with the quantitative planar scan method using 3 rectangular ROIs over each lung.

  20. Ventilation/perfusion SPECT/CT in patients with pulmonary emphysema. Evaluation of software-based analysing.

    Science.gov (United States)

    Schreiter, V; Steffen, I; Huebner, H; Bredow, J; Heimann, U; Kroencke, T J; Poellinger, A; Doellinger, F; Buchert, R; Hamm, B; Brenner, W; Schreiter, N F

    2015-01-01

    The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.

  1. Brain perfusion CT in acute stroke: current status

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Matthias E-mail: matthias.koenig@ruhr-uni-bochum.de

    2003-03-01

    Dynamic perfusion CT has become a widely accepted imaging modality for the diagnostic workup of acute stroke patients. Although compared with standard spiral CT the use of multislice CT has broadened the range from which perfusion data may be derived in a single scan run. The advent of multidetector row technology has not really overcome the limited 3D capability of this technique. Multidetector CT angiography (CTA) of the cerebral arteries may in part compensate for this by providing additional information about the cerebrovascular status. This article describes the basics of cerebral contrast bolus scanning with a special focus on optimization of contrast/noise in order to ensure high quality perfusion maps. Dedicated scan protocols including low tube voltage (80 kV) as well as the use of highly concentrated contrast media are amongst the requirements to achieve optimum contrast signal from the short bolus passage through the brain. Advanced pre and postprocessing algorithms may help reduce the noise level, which may become critical in unconscious stroke victims. Two theoretical concepts have been described for the calculation of tissue perfusion from contrast bolus studies, both of which can be equally employed for brain perfusion imaging. For each perfusion model there are some profound limitations regarding the validity of perfusion values derived from ischemic brain areas. This makes the use of absolute quantitative cerebral blood flow (CBF) values for the discrimination of the infarct core from periinfarct ischemia questionable. Multiparameter imaging using maps of CBF, cerebral blood volume (CBV), and a time parameter of the local bolus transit enables analyzing of the cerebral perfusion status in detail. Perfusion CT exceeds plain CT in depicting cerebral hypoperfusion at its earliest stage yielding a sensitivity of about 90% for the detection of embolic and hemodynamic lesions within cerebral hemispheres. Qualitative assessment of brain perfusion can be

  2. Quantitative pre-surgical lung function estimation with SPECT/CT

    International Nuclear Information System (INIS)

    Bailey, D. L.; Willowson, K. P.; Timmins, S.; Harris, B. E.; Bailey, E. A.; Roach, P. J.

    2009-01-01

    Full text:Objectives: To develop methodology to predict lobar lung function based on SPECT/CT ventilation and perfusion (V/Q) scanning in candidates for lobectomy for lung cancer. Methods: This combines two development areas from our group: quantitative SPECT based on CT-derived corrections for scattering and attenuation of photons, and SPECT V/Q scanning with lobar segmentation from CT. Eight patients underwent baseline pulmonary function testing (PFT) including spirometry, measure of DLCO and cario-pulmonary exercise testing. A SPECT/CT V/Q scan was acquired at baseline. Using in-house software each lobe was anatomically defined using CT to provide lobar ROIs which could be applied to the SPECT data. From these, individual lobar contribution to overall function was calculated from counts within the lobe and post-operative FEV1, DLCO and VO2 peak were predicted. This was compared with the quantitative planar scan method using 3 rectangular ROIs over each lung. Results: Post-operative FEV1 most closely matched that predicted by the planar quantification method, with SPECT V/Q over-estimating the loss of function by 8% (range - 7 - +23%). However, post-operative DLCO and VO2 peak were both accurately predicted by SPECT V/Q (average error of 0 and 2% respectively) compared with planar. Conclusions: More accurate anatomical definition of lobar anatomy provides better estimates of post-operative loss of function for DLCO and VO2 peak than traditional planar methods. SPECT/CT provides the tools for accurate anatomical defintions of the surgical target as well as being useful in producing quantitative 3D functional images for ventilation and perfusion.

  3. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  4. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    International Nuclear Information System (INIS)

    Weininger, Markus; Schoepf, U. Joseph; Ramachandra, Ashok; Fink, Christian; Rowe, Garrett W.; Costello, Philip; Henzler, Thomas

    2012-01-01

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  5. Pulmonary embolism: Prospective comparison of spiral CT with ventilation - perfusion scintigraphy

    International Nuclear Information System (INIS)

    Mayo Jhon R; Remi Jardin, Martine; Muller Mestor I

    1999-01-01

    The pulmonary thromboembolism (PTE) it is an entity common with great morbidity and mortality that it requires a diagnosis soon and specify. Commonly the ventilation gammagraphy - perfusion has been the used exam of first more frequent line when one suspects the PTE but unfortunately a great quantity of reports is called of intermediate probability, for what requires complementary studies, to confirm or to discard the diagnosis. A prospective study was made with 142 patients that had suspicion of TEP in the hospital of Vancouver (Canada) and in the hospital of Calmette (France), being carried out in all gammagraphy of ventilation-perfusion and helical CT, being only taken to lung angiography to those that not had high clinical suspicion of TEP with gammagraphy or helical CT very suggestive or tuneless, undergoing the results valuation for different observers

  6. Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion CT

    International Nuclear Information System (INIS)

    Tutcu, Semra; Serter, Selim; Kaya, Yavuz; Kara, Eray; Nese, Nalan; Pekindil, Goekhan; Coskun, Teoman

    2010-01-01

    Purpose: It is known that acute pancreatitis may cause secondary changes in several organs. Liver is one of these involved organs. In different experimental studies hepatic damages were shown histopathologically in acute pancreatitis but there are a few studies about perfusion disorders that accompany these histopathologic changes. Perfusion CT (pCT) provides the ability to detect regional and global alterations in organ blood flow. The purpose of the study was to describe hepatic perfusion changes in experimental acute pancreatitis model with pCT. Materials and methods: Forty Sprague-Dawley rats of both genders with average weights of 250 g were used. Rats were randomized into two groups. Twenty rats were in control group and 20 in acute pancreatitis group. pCT was performed. Perfusion maps were formed by processing the obtained images with perfusion CT software. Blood flow (BF) and blood volume (BV) values were obtained from these maps. All pancreatic and liver tissues were taken off with laparotomy and histopathologic investigation was performed. Student's t test was used for statistical analyses. Results: In pCT we found statistically significant increase in blood volume in both lobes of liver and in blood flow in right lobe of the liver (p < 0.01). Although blood flow in left lobe of the liver increased, it did not reach statistical significance. Conclusion: The quantitative analysis of liver parenchyma with pCT showed that acute pancreatitis causes a significant perfusion changes in the hepatic tissue. Systemic mediators seem to be effective as well as local inflammatory changes in perfusion changes.

  7. Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion CT

    Energy Technology Data Exchange (ETDEWEB)

    Tutcu, Semra [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey); Serter, Selim, E-mail: serterselim@gmail.co [Department of Radiology, Celal Bayar University, School of Medicine, Manisa (Turkey); Kaya, Yavuz; Kara, Eray [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey); Nese, Nalan [Department of Pathology, Celal Bayar University, School of Medicine, Manisa (Turkey); Pekindil, Goekhan [Department of Radiology, Celal Bayar University, School of Medicine, Manisa (Turkey); Coskun, Teoman [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey)

    2010-08-15

    Purpose: It is known that acute pancreatitis may cause secondary changes in several organs. Liver is one of these involved organs. In different experimental studies hepatic damages were shown histopathologically in acute pancreatitis but there are a few studies about perfusion disorders that accompany these histopathologic changes. Perfusion CT (pCT) provides the ability to detect regional and global alterations in organ blood flow. The purpose of the study was to describe hepatic perfusion changes in experimental acute pancreatitis model with pCT. Materials and methods: Forty Sprague-Dawley rats of both genders with average weights of 250 g were used. Rats were randomized into two groups. Twenty rats were in control group and 20 in acute pancreatitis group. pCT was performed. Perfusion maps were formed by processing the obtained images with perfusion CT software. Blood flow (BF) and blood volume (BV) values were obtained from these maps. All pancreatic and liver tissues were taken off with laparotomy and histopathologic investigation was performed. Student's t test was used for statistical analyses. Results: In pCT we found statistically significant increase in blood volume in both lobes of liver and in blood flow in right lobe of the liver (p < 0.01). Although blood flow in left lobe of the liver increased, it did not reach statistical significance. Conclusion: The quantitative analysis of liver parenchyma with pCT showed that acute pancreatitis causes a significant perfusion changes in the hepatic tissue. Systemic mediators seem to be effective as well as local inflammatory changes in perfusion changes.

  8. Study of lung perfusion in colagenosis

    Energy Technology Data Exchange (ETDEWEB)

    Macedo de Carvalho, A C; Calegaro, J U.M. [Fundacao Hospitalar do Distrito Federal, Distrito Federal (Brazil). Unidade de Medicina Nuclear

    1982-07-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized.

  9. Study of lung perfusion in colagenosis

    International Nuclear Information System (INIS)

    Macedo de Carvalho, A.C.; Calegaro, J.U.M.

    1982-01-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized. (author) [es

  10. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  11. Whole-brain dynamic CT angiography and perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Orrison, W.W. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); College of Osteopathic Medicine, Touro University Nevada, Henderson, NV (United States); Department of Health Physics and Diagnostic Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Department of Medical Education, University of Nevada School of Medicine, Reno, NV (United States); Snyder, K.V.; Hopkins, L.N. [Department of Neurosurgery, Millard Fillmore Gates Circle Hospital, Buffalo, NY (United States); Roach, C.J. [School of Life Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Ringdahl, E.N. [Department of Psychology, University of Nevada Las Vegas, Las Vegas, NV (United States); Nazir, R. [Shifa International Hospital, Islamabad (Pakistan); Hanson, E.H., E-mail: eric.hanson@amigenics.co [College of Osteopathic Medicine, Touro University Nevada, Henderson, NV (United States); Department of Health Physics and Diagnostic Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States)

    2011-06-15

    The availability of whole brain computed tomography (CT) perfusion has expanded the opportunities for analysing the haemodynamic parameters associated with varied neurological conditions. Examples demonstrating the clinical utility of whole-brain CT perfusion imaging in selected acute and chronic ischaemic arterial neurovascular conditions are presented. Whole-brain CT perfusion enables the detection and focused haemodynamic analyses of acute and chronic arterial conditions in the central nervous system without the limitation of partial anatomical coverage of the brain.

  12. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  13. Perfusion CT in childhood stroke—Initial observations and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Zebedin, D., E-mail: doris.zebedin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria); Sorantin, E.; Riccabona, M. [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria)

    2013-07-15

    Introduction: To report the preliminary results of contrast-enhanced perfusion multi-detector CT for diagnoses of perfusion disturbances in children with clinical suspicion of stroke. Patients and methods: Within the last two years emergency perfusion CT was performed in ten children (age: 8–17 years, male:female = 3:7) for assessment of suspected childhood stroke. These intracranial perfusion CT, intracranial CT-digital subtraction angiography (CT-DSA) and extracranial CT-angiography (CTA) studies were retrospectively reviewed and compared with MRI, follow-up CT, catheter angiography and final clinical diagnosis. The total dose length product (DLP) for the entire examination was recorded. The image quality of perfusion CT-maps, CT-DSA and CTA were evaluated with a subjective three-point scale ranging from very good to non-diagnostic image quality rating perfusion disturbance, intracranial peripheral vessel depiction, and motion- or streak artifacts. Results: In nine of ten children perfusion CT showed no false positive or false negative results. In one of ten children suffering from migraine focal hypo-perfusion was read as perfusion impairment potentially indicating early stroke, but MRI and MRA follow-up were negative. Overall, perfusion-CT with CT-DSA was rated very good in 80% of cases for the detection of perfusion disturbances and vessel anatomy. Conclusions: In comparison to standard CT, contrast-enhanced perfusion CT improves CTs’ diagnostic capability in the emergency examination of children with a strong suspicion of ischemic cerebral infarction.

  14. Added value of lung perfused blood volume images using dual-energy CT for assessment of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Okada, Munemasa; Kunihiro, Yoshie; Nakashima, Yoshiteru; Nomura, Takafumi; Kudomi, Shohei; Yonezawa, Teppei; Suga, Kazuyoshi; Matsunaga, Naofumi

    2015-01-01

    Purpose: To investigate the added value of lung perfused blood volume (LPBV) using dual-energy CT for the evaluation of intrapulmonary clot (IPC) in patients suspected of having acute pulmonary embolism (PE). Materials and methods: Institutional review board approval was obtained for this retrospective study. Eighty-three patients suspected of having PE who underwent CT pulmonary angiography (CTPA) using a dual-energy technique were enrolled in this study. Two radiologists who were blinded retrospectively and independently reviewed CTPA images alone and the combined images with color-coded LPBV over a 4-week interval, and two separate sessions were performed with a one-month interval. Inter- and intraobserver variability and diagnostic accuracy were evaluated for each reviewer with receiver operating characteristic (ROC) curve analysis. Results: Values for inter- and intraobserver agreement, respectively, were better for CTPA combined with LPBV (ICC = 0.847 and 0.937) than CTPA alone (ICC = 0.748 and 0.861). For both readers, diagnostic accuracy (area under the ROC curve [A z ]) were also superior, when CTPA alone (A z = 0.888 [reader 1] and 0.912 [reader 2]) was compared with that after the combination with LPBV images (A z = 0.966 [reader 1] and 0.959 [reader 2]) (p < 0.001). However, A z values of both images might not have significant difference in statistics, because A z value of CTPA alone was high and 95% confidence intervals overlapped in both images. Conclusion: Addition of dual-energy perfusion CT to CTPA improves detection of peripheral IPCs with better interobserver agreement

  15. Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Li; Xia, Yi; Guan, Yu; Yu, Hong; Liu, Shi-yuan [Changzheng Hospital of the Second Military Medical University, Department of Radiology, Shanghai (China); Zhang, Tie-feng; Li, Bing [Changzheng Hospital of the Second Military Medical University, Department of Respiration Medicine, Shanghai (China)

    2013-05-15

    To compare CT volume analysis with MR perfusion imaging in differentiating smokers with normal pulmonary function (controls) from COPD patients. Sixty-two COPD patients and 17 controls were included. The total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantified by CT. MR perfusion evaluated positive enhancement integral (PEI), maximum slope of increase (MSI), maximum slope of decrease (MSD), signal enhancement ratio (SER) and signal intensity ratio (R{sub SI}) of perfusion defects to normal lung. There were 19 class I, 17 class II, 14 class III and 12 class IV COPD patients. No differences were observed in TLV, TEV and EI between control and class I COPD. The control was different from class II, III and IV COPD in TEV and EI. The control was different from each class of COPD in R{sub SI,} MSI, PEI and MSD. Differences were found in R{sub SI} between class I and III, I and IV, and II and IV COPD. Amongst controls, MR detected perfusion defects more frequently than CT detected emphysema. Compared with CT, MR perfusion imaging shows higher potential to distinguish controls from mild COPD and appears more sensitive in identifying abnormalities amongst smokers with normal pulmonary function (controls). (orig.)

  16. Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging

    International Nuclear Information System (INIS)

    Fan, Li; Xia, Yi; Guan, Yu; Yu, Hong; Liu, Shi-yuan; Zhang, Tie-feng; Li, Bing

    2013-01-01

    To compare CT volume analysis with MR perfusion imaging in differentiating smokers with normal pulmonary function (controls) from COPD patients. Sixty-two COPD patients and 17 controls were included. The total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantified by CT. MR perfusion evaluated positive enhancement integral (PEI), maximum slope of increase (MSI), maximum slope of decrease (MSD), signal enhancement ratio (SER) and signal intensity ratio (R SI ) of perfusion defects to normal lung. There were 19 class I, 17 class II, 14 class III and 12 class IV COPD patients. No differences were observed in TLV, TEV and EI between control and class I COPD. The control was different from class II, III and IV COPD in TEV and EI. The control was different from each class of COPD in R SI, MSI, PEI and MSD. Differences were found in R SI between class I and III, I and IV, and II and IV COPD. Amongst controls, MR detected perfusion defects more frequently than CT detected emphysema. Compared with CT, MR perfusion imaging shows higher potential to distinguish controls from mild COPD and appears more sensitive in identifying abnormalities amongst smokers with normal pulmonary function (controls). (orig.)

  17. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  18. A Short Period of Ventilation without Perfusion Seems to Reduce Atelectasis without Harming the Lungs during Ex Vivo Lung Perfusion

    Directory of Open Access Journals (Sweden)

    Sandra Lindstedt

    2013-01-01

    Full Text Available To evaluate the lung function of donors after circulatory deaths (DCDs, ex vivo lung perfusion (EVLP has been shown to be a valuable method. We present modified EVLP where lung atelectasis is removed, while the lung perfusion is temporarily shut down. Twelve pigs were randomized into two groups: modified EVLP and conventional EVLP. When the lungs had reached 37°C in the EVLP circuit, lung perfusion was temporarily shut down in the modified EVLP group, and positive end-expiratory pressure (PEEP was increased to 10 cm H2O for 10 minutes. In the conventional EVLP group, PEEP was increased to 10 cm H2O for 10 minutes with unchanged lung perfusion. In the modified EVLP group, the arterial oxygen partial pressure (PaO2 was 18.5 ± 7.0 kPa before and 64.5 ± 6.0 kPa after the maneuver (P<0.001. In the conventional EVLP group, the PaO2 was 16.8 ± 3.1 kPa and 46.8 ± 2.7 kPa after the maneuver (P<0.01; P<0.01. In the modified EVLP group, the pulmonary graft weight was unchanged, while in the conventional EVLP group, the pulmonary graft weight was significantly increased. Modified EVLP with normoventilation of the lungs without ongoing lung perfusion for 10 minutes may eliminate atelectasis almost completely without harming the lungs.

  19. Dynamic (4D) CT perfusion offers simultaneous functional and anatomical insights into pulmonary embolism resolution

    Energy Technology Data Exchange (ETDEWEB)

    Mirsadraee, Saeed, E-mail: saeed.mirsadraee@ed.ac.uk [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Reid, John H.; Connell, Martin [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); MacNee, William; Hirani, Nikhil [The Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Murchison, John T. [Department of Radiology, Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA (United Kingdom); Beek, Edwin J. van [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom)

    2016-10-15

    Objective: Resolution and long-term functional effects of pulmonary emboli are unpredictable. This study was carried out to assess persisting vascular bed perfusion abnormalities and resolution of arterial thrombus in patients with recent pulmonary embolism (PE). Methods and materials: 26 Patients were prospectively evaluated by dynamic (4D) contrast enhanced CT perfusion dynamic pulmonary CT perfusion. Intermittent volume imaging was performed every 1.5–1.7 s during breath-hold and perfusion values were calculated by maximum-slope technique. Thrombus load (modified Miller score; MMS) and ventricular diameter were determined. Perfusion maps were visually scored and correlated with residual endoluminal filling defects. Results: The mean initial thrombus load was 13.1 ± 4.6 MMS (3–16), and 1.2 ± 2.1 MMS (0–8) at follow up. From the 24 CTPs with diagnostic quality perfusion studies, normal perfusion was observed in 7 (29%), and mildly-severely abnormal in 17 (71%). In 15 patients with no residual thrombus on follow up CTPA, normal perfusion was observed in 6, and abnormal perfusion in 9. Perfusion was abnormal in all patients with residual thrombus on follow up CTPA. Pulmonary perfusion changes were classified as reduced (n = 4), delayed (systemic circulation pattern; n = 5), and absent (no-flow; n = 5). The right ventricle was dilated in 12/25 (48%) at presentation, and normal in all 26 follow up scans. Weak correlation was found between initial ventricular dilatation and perfusion abnormality at follow up (r = 0.15). Conclusions: Most patients had substantial perfusion abnormality at 3–6 months post PE. Abnormal perfusion patterns were frequently observed in patients and in regions with no corresponding evidence of residual thrombus on CTPA. Some defects exhibit delayed, presumed systemic, enhancement (which we have termed ‘stunned’ lung). CT perfusion provides combined anatomical and functional information about PE resolution.

  20. CT perfusion study of neck lymph nodes

    International Nuclear Information System (INIS)

    Zhong Jin; Liu Jun; Hua Rui; Qiao Hui; Gong Yi

    2011-01-01

    Objective: To study the CT perfusion features of various lymph nodes in the neck. Methods: Dynamic perfusion CT scanning was performed in 83 neck lymph nodes proved by pathology, including tuberculosis lymph nodes, lymphoma and metastatic lymph nodes. The shapes, blood flow modes, and perfusion parameters of these lymph nodes were compared among 3 groups. Statistical analysis of L/T and CT perfusion parameters was performed by one-way ANOVA and LSD test. Results: The values of MTT of tuberculosis lymph nodes, lymphoma and metastatic lymph nodes were (28.13±5.08), (31.08±5.82), and (11.24±5.31) s, respectively. The MTT of metastatic lymph nodes was statistically lower than that of tuberculosis lymph nodes and lymphoma (P -1 · 100 g -1 , respectively. The values of BV were (24.68±2.84), (25.30±3.16), and (25.15± 8.81) ml·100 g -1 respectively. The values of TTP were (40.90±8.85), (40.67±6.45), and (40.98±6.62) s, respectively. There were no significant differences in L/T, BF, BV and TTP among tuberculosis lymph nodes, lymphoma and metastatic lymph nodes (P>0.05). Conclusion: CT perfusion, especially combination functional imaging with perfusion images may be helpful in judging the nature of neck lymph nodes. (authors)

  1. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    Science.gov (United States)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  2. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  3. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Li Jianjun; Zhai Renyou; Zhang Dongpo; Huang Qiang; Dai Dingke; Yu Ping; Bao Na

    2008-01-01

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4±15.7)ml·min -1 ·100 g -1 , (293.7± 7.9) ml·min -1 ·100 g -1 , (379.4±14.5)ml·min -1 ·100 g -1 , (382.5±16.6)ml·min -1 ·. 100 g -1 ] and [(3.1±0.2)s, (2.6±0.2)s, (2.2±0.1)s, (1.9±0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P 0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2± 19.2)ml·min -1 ·100 g -1 and (259.4±15.7) ml·min -1 ·100 g -1 in group A, (393.2±16.1) ml· min -1 ·100 g -1 and (293.7±7.9) ml·min -1 ·100 g -1 in group B] and MTF [(1.8±0.1)s and (3.1±0.2) s in group A, (1.8±0.2) s and (2.6±0.2) s in group B] were statistically different (P 0.05) between groups

  4. Regional assessment of treatment in lung cancer using lung perfusion and ventilation images

    International Nuclear Information System (INIS)

    Horikoshi, Masaki; Teshima, Takeo; Yanagimachi, Tomohiro; Ogata, Yuuko; Nukiwa, Toshihiro

    2000-01-01

    In 30 patients with lung cancer undergoing non-surgical treatment, we performed perfusion lung imaging using 99m Tc-MAA and inhalation lung studies using Technegas before and after treatment and evaluated regional perfusion and ventilation status in the lung regions where bronchogenic carcinoma was located. Regional ventilation status was preserved rather than perfusion counterpart (V>P) in 18 patients (18/30=60.0%) before treatment, while the former was better than the latter in 27 patients (27/30=90.0%) after treatment, indicating that regional ventilation status improved more significantly than regional perfusion counterpart after treatment (P=0.005). We also classified the therapeutic effect for regional perfusion and ventilation status as improved, unchanged, or worsened, respectively; improvement in regional perfusion status was observed in 17 patients (56.7%) and that in regional ventilation status in 24 patients (80.0%). There was a statistically significant correlation between improved regional perfusion and ventilation status (P=0.0018) when therapeutic effect was recognized. The patients who showed improvement in regional perfusion status after treatment always showed improved regional ventilation status, but 7 patients showed either unchanged or worsened regional perfusion status after treatment, although regional ventilation status was improved. In conclusion the pulmonary vascular beds seem more vulnerable to bronchogenic carcinoma and improvement in regional perfusion status was revealed to be more difficult than that in regional ventilation status after treatment. (author)

  5. Bronchiolitis obliterans syndrome: thin-section CT diagnosis of obstructive changes in infants and young children after lung transplantation.

    Science.gov (United States)

    Lau, D M; Siegel, M J; Hildebolt, C F; Cohen, A H

    1998-09-01

    To characterize the thin-section computed tomographic (CT) appearance of bronchiolitis fibrosa obliterans syndrome in infants and young children after lung transplantation. Thin-section CT studies in six patients with bronchiolitis obliterans syndrome (age range, 2 months to 5 1/2 years) and in 15 control patients without obstructive airway disease (age range, 2 months to 7 years) who underwent bilateral lung transplantation were retrospectively reviewed. The thin-section CT scans were obtained during quiet sleep at a median of 24 months (range, 6-36 months) after transplantation. The CT studies were evaluated for mosaic perfusion, bronchial dilatation, bronchial wall thickening, and mucous plugging Final diagnoses in all patients were based pulmonary function test results. Thin-section CT findings in the six patients with clinically proved bronchiolitis obliterans syndrome were mosaic perfusion in five (83%) bronchial dilation in three (50%), and bronchial wall thickening in one (17%). Of the 15 control patients with normal pulmonary function test results, six (40%) had mosaic perfusion; none had bronchial dilatation or bronchial wall thickening. Mucous plugging was not seen in either group. Only the association of bronchial dilatation with bronchiolitis obliterans syndrome was significant (P = .02). Infants and young children with bronchiolitis obliterans syndrome after lung transplantation are more likely to have CT abnormalities than those with normal pulmonary function test results.

  6. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  7. The relationship between ventilatory lung motion and pulmonary perfusion shown by ventilatory lung motion imaging

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Nakatsuka, Tatsuya; Yoshimura, Kazuhiko; Hirose, Yoshiki; Hirayama, Jiro; Kobayashi, Toshio; Handa, Kenjiro

    1991-01-01

    Using ventilatory lung motion imaging, which was obtained from two perfusion lung scintigrams with 99m Tc-macroaggregated albumin taken in maximal inspiration and maximal expiration, the lung motion (E-I/I) of the each unilateral lung was studied in various cardiopulmonary diseases. The sum of (E-I)/I(+) of the unilateral lung was decreased in the diseased lung for localized pleuropulmonary diseases, including primary lung cancer and pleural thickening, and in both lungs for heart diseases, and diffuse pulmonary diseases including diffuse interstitial pneumonia and diffuse panbronchiolitis. The sum of (E-I)/I(+) of the both lungs, which correlated with vital capacity and PaO 2 , was decreased in diffuse interstitial pneumonia, pulmonary emphysema, diffuse panbronchiolitis, primary lung cancer, pleural diseases and so on. (E-I)/I(+), correlated with pulmonary perfusion (n=49, r=0.51, p 81m Kr or 133 Xe (n=49, r=0.61, p<0.001) than pulmonary perfusion. The ventilatory lung motion imaging, which demonstrates the motion of the intra-pulmonary areas and lung edges, appears useful for estimating pulmonary ventilation of the perfused area as well as pulmonary perfusion. (author)

  8. Hypercapnic acidosis modulates inflammation, lung mechanics, and edema in the isolated perfused lung.

    Science.gov (United States)

    De Smet, Hilde R; Bersten, Andrew D; Barr, Heather A; Doyle, Ian R

    2007-12-01

    Low tidal volume (V(T)) ventilation strategies may be associated with permissive hypercapnia, which has been shown by ex vivo and in vivo studies to have protective effects. We hypothesized that hypercapnic acidosis may be synergistic with low V(T) ventilation; therefore, we studied the effects of hypercapnia and V(T) on unstimulated and lipopolysaccharide-stimulated isolated perfused lungs. Isolated perfused rat lungs were ventilated for 2 hours with low (7 mL/kg) or moderately high (20 mL/kg) V(T) and 5% or 20% CO(2), with lipopolysaccharide or saline added to the perfusate. Hypercapnia resulted in reduced pulmonary edema, lung stiffness, tumor necrosis factor alpha (TNF-alpha) and interleukin 6 (IL-6) in the lavage and perfusate. The moderately high V(T) did not cause lung injury but increased lavage IL-6 and perfusate IL-6 as well as TNF-alpha. Pulmonary edema and respiratory mechanics improved, possibly as a result of a stretch-induced increase in surfactant turnover. Lipopolysaccharide did not induce significant lung injury. We conclude that hypercapnia exerts a protective effect by modulating inflammation, lung mechanics, and edema. The moderately high V(T) used in this study stimulated inflammation but paradoxically improved edema and lung mechanics with an associated increase in surfactant release.

  9. Lung perfusion analysis with dual energy CT in patients with suspected pulmonary embolism—Influence of window settings on the diagnosis of underlying pathologies of perfusion defects

    International Nuclear Information System (INIS)

    Bauer, Ralf W.; Kerl, J. Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.

    2011-01-01

    Purpose: On lung perfusion analysis with dual energy CT (DECT) in patients with suspected pulmonary embolism (PE) commonly three patterns of perfusion defects (PD) are observed: wedge-shaped, circumscribed but not wedge-shaped, and patchy. We investigated the influence of different window settings on the identification of the underlying pathologies for these types of PD. Materials and methods: 3724 segments in 196 consecutive patients who underwent pulmonary DECT angiography for clinically suspected acute PE were analyzed. Iodine distribution in the lung parenchyma was calculated from the dual energy data and displayed as color map in axial, sagittal and coronal view. Afterwards, lung and angiography window were applied separately and assessed for pulmonary embolism and pathologies of the lung parenchyma. Results: 1420 segments in 141 patients showed PD, of which 276 were wedge-shaped, 287 circumscribed and 857 patchy. Circumscribed PD were associated in 99% with interstitial or alveolar fluid collections and in 1% with located bullae. Patchy PD were associated in 65% with emphysematous or fibrotic changes, in 38% with diffuse infiltrations or interstitial fluid collections and in 0.2% with PE. The underlying pathologies for wedge-shaped PD were in 78% PE, in 3% tumors compressing pulmonary arteries, in another 3% located bullae and in further 3% infiltrations. 13% (n = 15) of the segments in this group did not show vascular or parenchymal pathologies, but in 80% (n = 10) of these cases patients had PE in another segment. Totally n = 6 of wedge-shaped PD in 5 patients remained with unclear direct cause. Conclusion: Whereas patchy and circumscribed PD are almost exclusively associated with pathologies of the lung parenchyma, wedge-shaped PD are mostly associated with PE. For a small number of wedge-shaped PD the underlying cause cannot be detected with DECT. Very small peripherally situated micro-emboli may be discussed as a reason. However, prospective trials are

  10. Standardized perfusion value of the esophageal carcinoma and its correlation with quantitative CT perfusion parameter values

    Energy Technology Data Exchange (ETDEWEB)

    Djuric-Stefanovic, A., E-mail: avstefan@eunet.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Saranovic, Dj., E-mail: crvzve4@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Sobic-Saranovic, D., E-mail: dsobic2@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia); Masulovic, D., E-mail: draganmasulovic@yahoo.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Artiko, V., E-mail: veraart@beotel.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia)

    2015-03-15

    Purpose: Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. Methods: Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient (r{sub S}). Results: Median SPV of the esophageal carcinoma (7.1; range: 2.8–13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4–2.4), (Z = −5.511, p < 0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF (r{sub S} = 0.484, p = 0.002), BV (r{sub S} = 0.637, p < 0.001) and PS (r{sub S} = 0.432, p = 0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF (r{sub S} = 0.573, p < 0.001), BV (r{sub S} = 0.849, p < 0.001) and PS (r{sub S} = 0.761, p < 0.001). Conclusions: We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy

  11. Correlation of CT perfusion and CT volumetry in patients with Alzheimers disease

    International Nuclear Information System (INIS)

    Czarnecka, A.; Zimny, A.; Sasiadek, M.

    2010-01-01

    Background: Both brain atrophy and decrease of perfusion are observed in dementive diseases. The aim of the study was to correlate the results of brain perfusion CT (pCT) and CT volumetry in patients with Alzheimers disease (AD). Material/Methods: Forty-eight patients with AD (mean age of 71.3 years) underwent brain pCT and CT volumetry. The pCT was performed at the level of basal ganglia after the injection of contrast medium (50 ml, 4 ml/sec.) with serial scanning (delay 7 sec, 50 scans, 1 scan/sec). Volumetric measurements were carried out on the basis of source images, with the use of a dedicated CT software combined with manual outlining of the regions of interest in extracerebral and intraventricular CSF spaces. Perfusion parameters of the cerebral blood flow (CBF) and cerebral blood volume (CBV) from the grey matter of frontal and temporal as well as basal ganglia were compared statistically with the volumetric measurements of frontal and temporal cortical atrophy as well as subcortical atrophy. Results: A statistically significant positive correlation was found between the values of CBF and CBV in the basal ganglia and the volumes of the lateral and third ventricles. The comparison of CBF and CBV results with the volumetric measurements in the areas of the frontal and temporal lobes showed mostly negative correlations, but none of them was of statistical significance. Conclusions: In patients with AD, the degree of cortical atrophy is not correlated with the decrease of perfusion in the grey matter and subcortical atrophy is not correlated with the decrease of perfusion in the basal ganglia region. It suggests that functional and structural changes in AD are not related to each other. (authors)

  12. Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?

    Science.gov (United States)

    Mulé, Sébastien; Pigneur, Frédéric; Quelever, Ronan; Tenenhaus, Arthur; Baranes, Laurence; Richard, Philippe; Tacher, Vania; Herin, Edouard; Pasquier, Hugo; Ronot, Maxime; Rahmouni, Alain; Vilgrain, Valérie; Luciani, Alain

    2018-05-01

    To determine the degree of relationship between iodine concentrations derived from dual-energy CT (DECT) and perfusion CT parameters in patients with advanced HCC under treatment. In this single-centre IRB approved study, 16 patients with advanced HCC treated with sorafenib or radioembolization who underwent concurrent dynamic perfusion CT and multiphase DECT using a single source, fast kV switching DECT scanner were included. Written informed consent was obtained for all patients. HCC late-arterial and portal iodine concentrations, blood flow (BF)-related and blood volume (BV)-related perfusion parameters maps were calculated. Mixed-effects models of the relationship between iodine concentrations and perfusion parameters were computed. An adjusted p value (Bonferroni method) statistic (F)=28.52, padvanced HCC lesions, DECT-derived late-arterial iodine concentration is strongly related to both aBF and BV, while portal iodine concentration mainly reflects BV, offering DECT the ability to evaluate both morphological and perfusion changes. • Late-arterial iodine concentration is highly related to arterial BF and BV. • Portal iodine concentration mainly reflects tumour blood volume. • Dual-energy CT offers significantly decreased radiation dose compared with perfusion CT.

  13. Ventilation-perfusion lung imaging in diaphragmatic paralysis

    International Nuclear Information System (INIS)

    Chopra, S.K.; Taplin, G.V.

    1977-01-01

    Clinical, radiological, physiological, and lung imaging findings from a patient with paralysis of the diaphragm are described. Dyspnea, hypoxemia and hypercapnia increased when the patient changed from the upright to the supine positions. Ventilation (V) and perfusion (P) images of the right lung appeared to be relatively normal and remained nearly the same in the upright and supine positions. In contrast, V/P images of the left lung were smaller than those of the right lung in the upright position and decreased further in the supine position. In addition, the size of the ventilation image was much smaller than that of the perfusion

  14. High-resolution imaging of pulmonary ventilation and perfusion with 68Ga-VQ respiratory gated (4-D) PET/CT

    International Nuclear Information System (INIS)

    Callahan, Jason; Hofman, Michael S.; Siva, Shankar; Kron, Tomas; Schneider, Michal E.; Binns, David; Eu, Peter; Hicks, Rodney J.

    2014-01-01

    Our group has previously reported on the use of 68 Ga-ventilation/perfusion (VQ) PET/CT scanning for the diagnosis of pulmonary embolism. We describe here the acquisition methodology for 68 Ga-VQ respiratory gated (4-D) PET/CT and the effects of respiratory motion on image coregistration in VQ scanning. A prospective study was performed in 15 patients with non-small-cell lung cancer. 4-D PET and 4-D CT images were acquired using an infrared marker on the patient's abdomen as a surrogate for breathing motion following inhalation of Galligas and intravenous administration of 68 Ga-macroaggregated albumin. Images were reconstructed with phase-matched attenuation correction. The lungs were contoured on CT and PET VQ images during free-breathing (FB) and at maximum inspiration (Insp) and expiration (Exp). The similarity between PET and CT volumes was measured using the Dice coefficient (DC) comparing the following groups; (1) FB-PET/CT, (2) InspPET/InspCT, (3) ExpPET/Exp CT, and (4) FB-PET/AveCT. A repeated measures one-way ANOVA with multiple comparison Tukey tests were performed to evaluate any difference between the groups. Diaphragmatic motion in the superior-inferior direction on the 4-D CT scan was also measured. 4-D VQ scanning was successful in all patients without additional acquisition time compared to the nongated technique. The highest volume overlap was between ExpPET and ExpCT and between FB-PET and AveCT with a DC of 0.82 and 0.80 for ventilation and perfusion, respectively. This was significantly better than the DC comparing the other groups (0.78-0.79, p 68 Ga-VQ 4-D PET/CT is feasible and the blurring caused by respiratory motion is well corrected with 4-D acquisition, which principally reduces artefact at the lung bases. The images with the highest spatial overlap were the combined expiration phase or FB PET and average CT. With higher resolution than SPECT/CT, the PET/CT technique has a broad range of potential clinical applications including

  15. Hot spots on Tc-99m MAA perfusion lung scan

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Sohn, Myung Hee

    2001-01-01

    A 61 year-old woman underwent perfusion and inhalation lung scan for the evaluation of pulmonary thromboembolism. Tc-99m MAA perfusion lung scan showed multiple round hot spots in both lung fields. Tc-99m DTPA aerosol inhalation lung scan and chest radiography taken at the same time showed normal findings. A repeated perfusion lung scan taken 24 hours later demonstrated no abnormalities. Hot spots on perfusion lung scan can be caused by microsphere clumping due to faulty injection technique by radioactive embolization from upper extremity thrombophlebitis after injection. Focal hot spots can signify zones of atelectasis, where the hot spots probably represent a failure of hypoxic vasoconstriction. Artifactual hot spots due to microsphere clumping usually appear to be round and in peripheral location, and the lesions due to a loss of hypoxic vasoconstriction usually appear to be hot uptakes having linear borders. Although these artifactual hot spots have been well-known, we rarely encounter them. This report presents a case with artifactual hot spots due to microsphere clumping on Tc-99m MAA perfusion lung scan

  16. Thin-section spiral CT evaluation of morphologic effects of aging lung in asymptomatic adult subjects

    International Nuclear Information System (INIS)

    Li Kuncheng; Liu Jian; Yang Yanhui; Yao Xinyu; Yin Jianguo; Wang Shiwen; He Zuoxiang

    2006-01-01

    Objective: To evaluate the imaging signs of aging lung in asymptomatic adult subjects by using thin-section spiral CT, and analyze the correlation between the signs and the age of examined cases, as well as probe their clinical application value. Methods: One hundred and six healthy adult subjects were divided into 3 groups: 30 to 44 years (n=31), 45 to 59 years (n=30), and over 60 years (n=45), and all the subjects underwent thin-section spiral CT scans in the upper lung field, the middle lung field and the lower lung field. The evaluation indices included the lung interstitium changes, emphysematous changes, mosaic perfusion, dependent density difference, and pleural thickenning. According to the relative score standard, the above-mentioned indices were totally calculated and converted into the score value. The data were statistically processed with SPSS for Windows. Results: Among the three groups, there were remarkable differences in the indices including the lung interstitium changes, emphysematous changes, and mosaic perfusion, respectively (χ 2 =8.10, 9.73, 15.54, P 2 =3.66, 3.24, P> 0.05). The score values had a significant positive correlation with the age (r=0.709, P<0.01). Conclusion: The signs including the lung interstitium changes, emphysematous changes, mosaic perfusion, the dependent density difference, and pleural thickenning can be found in asymptomatic subjects, and they become prominent as the age increases. HRCT is one of the most important methods for evaluating the early signs of the senile lung. (authors)

  17. Local cortical hypoperfusion imaged with CT perfusion during postictal Todd's paresis

    International Nuclear Information System (INIS)

    Mathews, Marlon S.; Binder, Devin K.; Smith, Wade S.; Wintermark, Max; Dillon, William P.

    2008-01-01

    Postictal (''Todd's'') paralysis, or ''epileptic hemiplegia,'' is a well-known complication of focal or generalized epileptic seizures. However, it is unclear whether the pathophysiology of Todd's paralysis is related to alterations in cerebral perfusion. We report CT perfusion findings in a patient presenting with postictal aphasia and right hemiparesis. A 62-year-old woman with a history of alcohol abuse, closed head injury and posttraumatic epilepsy, presented with acute onset aphasia and right hemiparesis. A non-contrast head CT scan demonstrated no acute hemorrhage. Left hemispheric ischemia was suspected, and the patient was considered for acute thrombolytic therapy. MRI revealed a subtle increase in signal intensity involving the left medial temporal, hippocampal and parahippocampal regions on both T2-weighted FLAIR and diffusion-weighted sequences. CT angiography and CT perfusion study were performed. The CT perfusion study and CT angiography demonstrated a dramatic reduction in cerebral blood flow and blood volume involving the entire left hemisphere, but with relative symmetry of mean transit time, ruling out a large vessel occlusion. Clinical resolution of the aphasia and hemiparesis occurred within a few hours, and correlated with normalization of perfusion to the left hemisphere (detected by MR perfusion). This unique case is the first in which clinical evidence of Todd's paralysis has been correlated with reversible postictal hemispheric changes on CT and MR perfusion studies. This is important because CT perfusion study is being used more and more in the diagnosis of acute stroke, and one needs to be careful to not misinterpret the data. (orig.)

  18. Brain perfusion-CT in acute stroke patients

    International Nuclear Information System (INIS)

    Andreev, T.; Totsev, N.; Tzvetanov, P.

    2013-01-01

    Since 1979 when Grodfrey Hounsfield and Allan Corman introduced the computed tomography new generations of CT were developed that improved the special resolution and time of acquisition. The role of neuro-imaging in the evaluation of acute stroke has changed dramatically in the past decade. Previously, neuro-imaging was used in this set-ting to provide anatomic imaging that indicated the presence or absence of acute cerebral ischemia and excluded lesions that produce symptoms or signs mimicking those of stroke, such as hemorrhage and neoplasms. More recently, the introduction of thrombolysis has changed the goals of neuro-imaging from providing solely anatomic information to providing physiologic information that could help to determine which patients might benefit from therapy. In particular, significant emphasis has been placed on the delineation of the ischemic penumbra, also called tissue at risk. Modem CT survey, consisting of three indissociable elements; noncontrast CT (NCT) of course, perfusion-CT (PCT) and CT-angiography (CTA), fulfill all the requirements for hyperacute stroke imaging. CTA can define the occlusion site, depict arterial dissection, grade collateral blood flow, and characterize atherosclerotic disease, whereas PCT accurately defines the infarct core and the ischemic penumbra. CT offers a number of practical advantages over other cerebral perfusion imaging methods, including its wide availability. Using PCT and CTA to define new individualized strategies for acute reperfusion will allow more acute stroke patients to benefit from thrombolytic therapy. Key words: Stroke. Penumbra. Computed Tomography. Perfusion-CT. CT Angiography. Outcome

  19. The incorporation of SPECT functional lung imaging into inverse radiotherapy planning for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Christian, Judith A.; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; McNair, Helen A.; Cronin, Bernadette; Courbon, Frederic; Bedford, James L.; Brada, Michael

    2005-01-01

    Background and purpose: Patients with non-small cell lung cancer (NSCLC) often have inhomogeneous lung perfusion. Radiotherapy planning computed tomography (CT) scans have been accurately co-registered with lung perfusion single photon emission computed tomography (SPECT) scans to design radiotherapy treatments which limit dose to healthy 'perfused' lung. Patients and methods: Patients with localised NSCLC had CT and SPECT scans accurately co-registered in the planning system. The SPECT images were used to define a volume of perfused 'functioning' lung (FL). Inverse planning software was used to create 3D-conformal plans, the planning objective being either to minimise the dose to whole lungs (WL) or to minimise the dose to FL. Results: Four plans were created for each of six patients. The mean difference in volume between WL and FL was 1011.7 cm 3 (range 596.2-1581.1 cm 3 ). One patient with bilateral upper lobe perfusion deficits had a 16% reduction in FLV 2 (the percentage volume of functioning lung receiving ≥20 Gy). The remaining patients had inhomogeneous perfusion deficits such that inverse planning was not able to sufficiently optimise beam angles to avoid functioning lung. Conclusion: SPECT perfusion images can be accurately co-registered with radiotherapy planning CT scans and may be helpful in creating treatment plans for patients with large perfusion deficits

  20. Reversible ventilation and perfusion abnormalities in unilateral obstructed lung

    International Nuclear Information System (INIS)

    Ward, H.E.; Jones, R.L.; King, E.G.; Sproule, B.J.; Fortune, R.L.

    1982-01-01

    An intraluminal carcinoid tumor obstructing the left mainstem bronchus produced hypoxemia through alteration in ventilation/perfusion matching. Studies of regional lung function using 133-xenon (/sup 133/Xe) and a multiprobe computerized instrumentation system documented a reduction of perfusion to 22 percent and ventilation to 6 percent of the total. There was negligible washout of intravenously injected /sup 133/Xe from the left lung consistent with air trapping. Four days after left mainstem bronchial sleeve resection, perfusion, ventilation and washout of injected xenon had significantly improved and by four months postresection, all measurements were virtually normal, although complete restoration of perfusion in relation to ventilation was delayed. Regional lung function studied with a multiprobe system in this patient provided a clinical model for the study of ventilation and perfusion inter-relationships in large airway obstruction and demonstrated that a prolonged time may be required for return of perfusion to normal

  1. A study of whole brain perfusion CT and CT angiography in hyperacute and acute cerebral infarction

    International Nuclear Information System (INIS)

    Zhang Yonghai; Bai Junhu; Zhang Ming; Yang Guocai; Tang Guibo; Fang Jun; Shi Wei; Li Xinghua; Liu Suping; Lu Qing; Tang Jun

    2005-01-01

    Objective: To evaluate the diagnostic value of whole-brain perfusion blood volume-weighted CT imaging (PWCT) and simultaneous CT angiography (CTA) on early stage of cerebral ischemic infarction. Methods: Non-contrast CT (NCCT), CT perfusion-weighted imaging (PWCT) and delayed CT (DCT) were conducted on 20 cases of early ischemic infarction of whose onset time ranged from 2 to 24 hours. All cases were reexamined with CT or MRI one week to one month later. CT values and perfusion blood volume (PBV) of central and peripheral low perfusion areas as well as those of collateral side were measured. CTA was reconstructed with PWCT as source images to evaluate occlusion or stenosis of blood vessel, and DCT was used to detect the collateral circulation. Results: Of the 20 cases, NCCT, PWCT and CTA were negative in 10 cases in which 6 were confirmed as Transient Ischemic Attack (TIA) on reexamined CT and clinical features, and the other 4 were confirmed as lacunar infarction. For the remaining 10 cases, a comparison was made with ANOVA between low perfusion area (central, peripheral inside and outside) and collateral side. The difference was significant (P<0.01). However, no significant difference was revealed in the central, peripheral inside and outside areas. PBV values were significant in low perfusion area and collateral side (P<0.05). The area of the final infarction was larger than that of the low perfusion area, and the percentage of enlargement exhibited medium negative correlation to the time of ischemia. CTA indicated that 2 cases suffered from left middle cerebral artery occlusion, meanwhile anterior and middle branches of MCA in the other 3 cases were not identified. The sensitivity of NCCT, PWCT and CTA were 28.5%, 71.4% and 35.7% respectively. DCT indicated that 5 cases had asymmetrical blood vessels. Conclusion: The whole-brain perfusion-weighted CT imaging and simultaneous CT angiography (CTA) is p roved to be a simple, timesaving and effective method for the

  2. Regional cortical hyper perfusion on perfusion CT during postical motor deficit: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Hye Jin [Dept. of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2013-08-15

    Postictal neurologic deficit is a well-known complication mimicking the manifestation of a stroke. We present a case of a patient with clinical evidence of Todd's paralysis correlating with reversible postictal parenchymal changes on perfusion CT and magnetic resonance (MR) imaging. In this case, perfusion CT and MR imaging were helpful in the differential diagnosis of stroke-mimicking conditions.

  3. State-of-the-art radiological techniques improve the assessment of postoperative lung function in patients with non-small cell lung cancer

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Takenaka, Daisuke; Onishi, Yumiko; Matsumoto, Keiko; Matsumoto, Sumiaki; Maniwa, Yoshimasa; Yoshimura, Masahiro; Nishimura, Yoshihiro; Sugimura, Kazuro

    2011-01-01

    Purpose: The purpose of this study was to compare predictive capabilities for postoperative lung function in non-small cell lung cancer (NSCLC) patients of the state-of-the-art radiological methods including perfusion MRI, quantitative CT and SPECT/CT with that of anatomical method (i.e. qualitative CT) and traditional nuclear medicine methods such as planar imaging and SPECT. Materials and methods: Perfusion MRI, CT, nuclear medicine study and measurements of %FEV 1 before and after lung resection were performed for 229 NSCLC patients (125 men and 104 women). For perfusion MRI, postoperative %FEV 1 (po%FEV 1 ) was predicted from semi-quantitatively assessed blood volumes within total and resected lungs, for quantitative CT, it was predicted from the functional lung volumes within total and resected lungs, for qualitative CT, from the number of segments of total and resected lungs, and for nuclear medicine studies, from uptakes within total and resected lungs. All SPECTs were automatically co-registered with CTs for preparation of SPECT/CTs. Predicted po%FEV 1 s were then correlated with actual po%FEV 1 s, which were measured %FEV 1 s after operation. The limits of agreement were also evaluated. Results: All predicted po%FEV 1 s showed good correlation with actual po%FEV 1 s (0.83 ≤ r ≤ 0.88, p < 0.0001). Perfusion MRI, quantitative CT and SPECT/CT demonstrated better correlation than other methods. The limits of agreement of perfusion MRI (4.4 ± 14.2%), quantitative CT (4.7 ± 14.2%) and SPECT/CT (5.1 ± 14.7%) were less than those of qualitative CT (6.0 ± 17.4%), planar imaging (5.8 ± 18.2%), and SPECT (5.5 ± 16.8%). Conclusions: State-of-the-art radiological methods can predict postoperative lung function in NSCLC patients more accurately than traditional methods.

  4. State-of-the-art radiological techniques improve the assessment of postoperative lung function in patients with non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yoshiharuohno@aol.com [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2 Minatojima Minami-machi, Chuo-ku, Kobe, Hyogo, 650-0047 (Japan); Takenaka, Daisuke; Onishi, Yumiko; Matsumoto, Keiko; Matsumoto, Sumiaki [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Maniwa, Yoshimasa [Division of Cardiovascular, Thoracic and Pediatric Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Yoshimura, Masahiro [Division of Cardiovascular, Thoracic and Pediatric Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Division of Thoracic Surgery, Hyogo Cancer Center, 13-7 Kitaohji-cho, Akashi, Hyogo, 673-8558 (Japan); Nishimura, Yoshihiro [Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2011-01-15

    Purpose: The purpose of this study was to compare predictive capabilities for postoperative lung function in non-small cell lung cancer (NSCLC) patients of the state-of-the-art radiological methods including perfusion MRI, quantitative CT and SPECT/CT with that of anatomical method (i.e. qualitative CT) and traditional nuclear medicine methods such as planar imaging and SPECT. Materials and methods: Perfusion MRI, CT, nuclear medicine study and measurements of %FEV{sub 1} before and after lung resection were performed for 229 NSCLC patients (125 men and 104 women). For perfusion MRI, postoperative %FEV{sub 1} (po%FEV{sub 1}) was predicted from semi-quantitatively assessed blood volumes within total and resected lungs, for quantitative CT, it was predicted from the functional lung volumes within total and resected lungs, for qualitative CT, from the number of segments of total and resected lungs, and for nuclear medicine studies, from uptakes within total and resected lungs. All SPECTs were automatically co-registered with CTs for preparation of SPECT/CTs. Predicted po%FEV{sub 1}s were then correlated with actual po%FEV{sub 1}s, which were measured %FEV{sub 1}s after operation. The limits of agreement were also evaluated. Results: All predicted po%FEV{sub 1}s showed good correlation with actual po%FEV{sub 1}s (0.83 {<=} r {<=} 0.88, p < 0.0001). Perfusion MRI, quantitative CT and SPECT/CT demonstrated better correlation than other methods. The limits of agreement of perfusion MRI (4.4 {+-} 14.2%), quantitative CT (4.7 {+-} 14.2%) and SPECT/CT (5.1 {+-} 14.7%) were less than those of qualitative CT (6.0 {+-} 17.4%), planar imaging (5.8 {+-} 18.2%), and SPECT (5.5 {+-} 16.8%). Conclusions: State-of-the-art radiological methods can predict postoperative lung function in NSCLC patients more accurately than traditional methods.

  5. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tokihiro, E-mail: toyamamoto@ucdavis.edu [Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California 95817 (United States); Kent, Michael S.; Wisner, Erik R. [Department of Surgical and Radiological Sciences, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Johnson, Lynelle R.; Stern, Joshua A. [Department of Medicine and Epidemiology, University of California Davis School of Veterinary Medicine, Davis, California 95616 (United States); Qi, Lihong [Department of Public Health Sciences, University of California Davis, Davis, California 95616 (United States); Fujita, Yukio [Department of Radiation Oncology, Tokai University, Isehara, Kanagawa 259-1193 (Japan); Boone, John M. [Department of Radiology, University of California Davis School of Medicine, Sacramento, California 95817 (United States)

    2016-07-15

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  6. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model.

    Science.gov (United States)

    Yamamoto, Tokihiro; Kent, Michael S; Wisner, Erik R; Johnson, Lynelle R; Stern, Joshua A; Qi, Lihong; Fujita, Yukio; Boone, John M

    2016-07-01

    Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. The mean TRE

  7. Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

    International Nuclear Information System (INIS)

    Yamamoto, Tokihiro; Kent, Michael S.; Wisner, Erik R.; Johnson, Lynelle R.; Stern, Joshua A.; Qi, Lihong; Fujita, Yukio; Boone, John M.

    2016-01-01

    Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t

  8. Hemodynamic study on liver cirrhosis: clinical application of CT perfusion imaging

    International Nuclear Information System (INIS)

    Jiang Li; Yang Jianyong; Xie Hongbo; Yang Xufeng; Yan Chaogui; Li Ziping; Zeng Fang

    2004-01-01

    Objective: To estimate hepatic perfusion parameters with helical CT, and to study the relationship between hepatic perfusion parameters and the severity of liver cirrhosis. Methods: Dynamic single-section computed tomography (CT) of the liver was performed in 40 participants, including 27 patients with liver cirrhosis and 13 patients without liver disease (control subjects). CT scans were obtained at a single level to include the liver, spleen, aorta, and portal vein. On each CT scan, the attenuation of these organs was measured in regions of interest to provide time-density curves. The arterial, portal venous, and total perfusion of the liver and the hepatic perfusion index were assessed. Results: In the control group, hepatic arterial perfusion, portal venous perfusion, and total hepatic perfusion were (0.2823 ± 0.0969) ml·min -1 ·ml -1 , (1.1788 ± 0.4004) ml·min -1 ·ml -1 , and (1.4563 ± 0.4439) ml·min -1 ·ml -1 , respectively. Hepatic perfusion index was (19.73 ±5.81)%. These hepatic perfusion parameters correlated significantly with the severity of liver cirrhosis. Hepatic arterial perfusion decreased in Child A and B cirrhotic patients [ (0.1685 ± 0.1068) ml·min -1 ·ml -1 and (0.1921 ± 0.0986) ml·min -1 ·ml -1 , respectively]. Comparing to Child A and B cirrhotic patients, hepatic arterial perfusion in Child C cirrhotic patients [(0.3072 · 0.1145) ml·min -1 ·ml -1 ] raised significantly. Portal venous perfusion decreased significantly in Child B and C cirrhotic patients [(0.6331±0.2070) ml·min -1 ·ml -1 and (0.5702 ± 0.3562) ml·min -1 ·ml -1 , respectively]. Total hepatic blood flow reduced markedly in Child B and C cirrhotic patients [(0.8252 ± 0.2952) ml·min -1 ·ml -1 and (0.8774 ± 0.4118) ml·min -1 ·ml -1 , respectively]. Hepatic perfusion index increased in Child C cirrhotic patients (37.48 ± 16.65)%. Conclusion: Dynamic single-section CT showed potential in quantifying hepatic perfusion parameters, and hepatic perfusion

  9. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  10. Perfusion lung scanning: differentiation of primary from thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Lisbona, R.; Kreisman, H.; Novales-Diaz, J.; Derbekyan, V.

    1985-01-01

    Of eight patients with pulmonary arterial hypertension, final diagnosis established by autopsy or angiography, four had primary hypertension and four hypertension from thromboembolism. The perfusion lung scan was distinctly different in the two groups. The lung scan in primary pulmonary hypertension was associated with nonsegmental, patchy defects of perfusion, while in thromboembolic hypertensives it was characterized by segmental and/or lobar defects of perfusion with or without subsegmental defects. The perfusion lung scan is a valuable, noninvasive study in the evaluation of the patient with pulmonary hypertension of undetermined cause and in the exclusion of occult large-vessel pulmonary thromboembolism

  11. Kombineret ventilations/perfusions-SPECT/CT er bedst til diagnostik af lungeemboli

    DEFF Research Database (Denmark)

    Gutte Borgwardt, Henrik; Mortensen, Jann; Kristoffersen, Ulrik Sloth

    2012-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer test and imaging with either lung scintigraphy or pulmonary multidetector computed tomography angiography (CTA). Which of the two methods to use in PE diagnostic has not been determined...... and very limited data comparing these modalities are available. With the use of hybrid scanners, ventilation/perfusion-single-photon-emission-tomography (V/Q-SPECT) in combination with low-dose CT without contrast enhancement is feasible and should probably be considered first-line imaging in diagnosing PE....

  12. The preliminary study of CT cerebral perfusion imaging in transient ischemic attacks

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Du Xiangying

    2002-01-01

    Objective: To probe the application of CT cerebral perfusion imaging on transient ischemic attacks (TIA). Methods: Conventional CT and CT cerebral perfusion imaging were performed on 5 normal adults and 20 patients with clinically diagnosed TIA. After regular CT examination, dynamic scans of 40 seconds were performed on selected slice (usually on the basal ganglia slice), while 40 ml non-ionic contrast material were bolus injected through antecubital vein with. These dynamic images were processed with the 'Perfusion CT' software package on a PC based workstation. Cerebral blood flow (CBF) and time to peak (TP) enhancement were measured within specific regions of the brain on CT perfusion images. Quantitative analysis was performed for these images. Results: A gradient of perfusion between gray matter and white matter was showed on cT perfusion images in normal adults and TIA patients. CBF and TP for normal cortical and white matter were 378.2 ml·min -1 ·L -1 , 7.8 s and 112.5 ml·min -1 ·L -1 , 9.9 s, respectively. In 20 cases with TIA, persisting abnormal perfusion changes corresponding to clinical symptoms were found in 15 cases with prolonged TP. Other 5 cases showed normal results. TP of affected side (11.8 +- 4.4) s compared with that of the contralateral side (9.1 +- 3.1) s was significantly prolonged (t = 5.277, P -1 · -1 ] and contralateral side [(229.1 +- 41.4) ml·min -1 ·L -1 ]. Conclusion: Perfusion CT provides valuable hemodynamic information and shows the extent of perfusion disturbances for patients with TIA

  13. High-resolution imaging of pulmonary ventilation and perfusion with {sup 68}Ga-VQ respiratory gated (4-D) PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, Jason [Centre for Molecular Imaging, Peter MacCallum Cancer Centre, East Melbourne, VIC (Australia); Hofman, Michael S. [The University of Melbourne, Department of Medicine, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia); Siva, Shankar [The University of Melbourne, Peter MacCallum Cancer Centre, Department of Radiation Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); Kron, Tomas [The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Peter MacCallum Cancer Centre, Department of Physical Sciences, East Melbourne, VIC (Australia); Schneider, Michal E. [Monash University, Department of Medical Imaging and Radiation Science, Clayton, VIC (Australia); Binns, David; Eu, Peter [Peter MacCallum Cancer Centre, Centre for Cancer Imaging, East Melbourne, VIC (Australia); Hicks, Rodney J. [The University of Melbourne, Sir Peter MacCallum Department of Oncology, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia)

    2014-02-15

    Our group has previously reported on the use of {sup 68}Ga-ventilation/perfusion (VQ) PET/CT scanning for the diagnosis of pulmonary embolism. We describe here the acquisition methodology for {sup 68}Ga-VQ respiratory gated (4-D) PET/CT and the effects of respiratory motion on image coregistration in VQ scanning. A prospective study was performed in 15 patients with non-small-cell lung cancer. 4-D PET and 4-D CT images were acquired using an infrared marker on the patient's abdomen as a surrogate for breathing motion following inhalation of Galligas and intravenous administration of {sup 68}Ga-macroaggregated albumin. Images were reconstructed with phase-matched attenuation correction. The lungs were contoured on CT and PET VQ images during free-breathing (FB) and at maximum inspiration (Insp) and expiration (Exp). The similarity between PET and CT volumes was measured using the Dice coefficient (DC) comparing the following groups; (1) FB-PET/CT, (2) InspPET/InspCT, (3) ExpPET/Exp CT, and (4) FB-PET/AveCT. A repeated measures one-way ANOVA with multiple comparison Tukey tests were performed to evaluate any difference between the groups. Diaphragmatic motion in the superior-inferior direction on the 4-D CT scan was also measured. 4-D VQ scanning was successful in all patients without additional acquisition time compared to the nongated technique. The highest volume overlap was between ExpPET and ExpCT and between FB-PET and AveCT with a DC of 0.82 and 0.80 for ventilation and perfusion, respectively. This was significantly better than the DC comparing the other groups (0.78-0.79, p < 0.05). These values agreed with a visual inspection of the images with improved image coregistration around the lung bases. The diaphragmatic motion during the 4-D CT scan was highly variable with a range of 0.4-3.4 cm (SD 0.81 cm) in the right lung and 0-2.8 cm (SD 0.83 cm) in the left lung. Right-sided diaphragmatic nerve palsy was observed in 3 of 15 patients. {sup 68}Ga-VQ 4-D

  14. Prediction of residual lung function after lung surgery, and examination of blood perfusion in the pre- and postoperative lung using three-dimensional SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Shimatani, Shinji [Toho Univ., Tokyo (Japan). School of Medicine

    2001-01-01

    In order to predict postoperative pulmonary function after lung surgery, preoperative {sup 99m}Tc-macroaggregated albumin (MAA) lung perfusion scans with single-photon emission computed tomography (SPECT) were performed. Spirometry was also performed before and 4-6 months after surgery in 40 patients. In addition, changes in blood perfusion in the pre- and postoperative lung were examined by postoperative lung perfusion scans in 18 of the 40 patients. We measured the three-dimensional (3-D) imaging volume of the operative and contralateral lungs using the volumes rendering method at blood perfusion thresholds of 20, 50 and 75%, utilizing {sup 99m}Tc-MAA lung perfusion, and predicted pulmonary function by means of the measured volumes. We examined the correlation between predicted and the measured values of postoperative pulmonary function, forced vital capacity (FVC) and forced expiratory volume in one second (FEV{sub 1.0}). The correlation between FEV{sub 1.0} predicted by SPECT (threshold 50%) and measured postoperative lung function resembled that between lung function predicted by the standard planar method and measured FEV{sub 1.0} in the lobectomy group. We then examined the ratios of both pre- and postoperative blood perfusion volumes obtained using 3-D imaging at lung perfusion threshold ranges of 10% each (PV20-29, PV30-39) to pre- and postoperative total perfusion (PV20-100). In the lobectomy group, the postoperative PV20-29/PV20-100 value was significantly higher for the operative side lung than the preoperative PV20-29/PV20-100 value, and the postoperative PV50-59, 60-69, 70-79, 80-89 and 90-100/PV20-100 values were significantly lower than the respective preoperative values. However, in the contralateral lung, the respective pre- and postoperative PV/PV20-100 values were almost identical. These findings suggest that the rate of low blood perfusion increased while the rate of middle to high perfusion decreased in the lobectomy group in the operative

  15. Role of perfusion SPECT in prediction and measurement of pulmonary complications after radiotherapy for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Farr, Katherina P.; Khalil, Azza A.; Grau, Cai [Aarhus University Hospital, Department of Oncology, Aarhus C (Denmark); Kramer, Stine; Morsing, Anni [Aarhus University Hospital, Department of Nuclear Medicine and PET Centre, Aarhus C (Denmark)

    2015-07-15

    The purpose of the study was to evaluate the ability of baseline perfusion defect score (DS) on SPECT to predict the development of severe symptomatic radiation pneumonitis (RP) and to evaluate changes in perfusion on SPECT as a method of lung perfusion function assessment after curative radiotherapy (RT) for non-small-cell lung cancer (NSCLC). Patients with NSCLC undergoing curative RT were included prospectively. Perfusion SPECT/CT and global pulmonary function tests (PFT) were performed before RT and four times during follow-up. Functional activity on SPECT was measured using a semiquantitative perfusion DS. Pulmonary morbidity was graded by the National Cancer Institute's Common Terminology Criteria for Adverse Events version 4 for pneumonitis. Patients were divided into two groups according to the severity of RP. A total of 71 consecutive patients were included in the study. Baseline DS was associated with chronic obstructive pulmonary disease. A significant inverse correlation was found between baseline DS and forced expiratory volume in 1 s and diffusing capacity of the lung for carbon monoxide. Patients with severe RP had significantly higher baseline total lung DS (mean 5.43) than those with no or mild symptoms (mean DS 3.96, p < 0.01). PFT results were not different between these two groups. The odds ratio for total lung DS was 7.8 (95 % CI 1.9 - 31) demonstrating the ability of this parameter to predict severe RP. Adjustment for other potential confounders known to be associated with increased risk of RP was performed and did not change the odds ratio. The median follow-up time after RT was 8.4 months. The largest DS increase of 13.3 % was associated with severe RP at 3 months of follow-up (p < 0.01). The development of severe RP during follow-up was not associated with changes in PFT results. Perfusion SPECT is a valuable method for predicting severe RP and for assessing changes in regional functional perfusion after curative RT comparable with

  16. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    Energy Technology Data Exchange (ETDEWEB)

    Jianjun, Li; Renyou, Zhai; Dongpo, Zhang; Qiang, Huang; Dingke, Dai; Ping, Yu; Na, Bao [Department of Radiology, Beijing Chaoyang Hospital, Capital Medical Univ., Beijing (China)

    2008-10-15

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4{+-}15.7)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (293.7{+-} 7.9) ml{center_dot}min{sup -1{center_dot}}100 g {sup -1}, (379.4{+-}14.5)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (382.5{+-}16.6)ml{center_dot}min{sup -1{center_dot}}. 100 g{sup -1}] and [(3.1{+-}0.2)s, (2.6{+-}0.2)s, (2.2{+-}0.1)s, (1.9{+-}0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P<0.01) between groups (A and B, A and C, A and D, B and C, B and D) except between group C and D (the P value >0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2{+-} 19.2)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1} and (259

  17. Prediction of postoperative pulmonary function using 99mTc-MAA perfusion lung SPECT

    International Nuclear Information System (INIS)

    Hosokawa, Nobuyuki; Tanabe, Masatada; Satoh, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Maeda, Masazumi; Tamai, Toyosato; Kojima, Kanji.

    1995-01-01

    In order to predict postoperative pulmonary function, 99m Tc-MAA perfusion lung SPECT and spirometry were performed preoperatively in 52 patients with resectable primary lung cancer; 44 underwent lobectomy, eight pneumonectomy. Local pulmonary function (called local effective volume) was evaluated according to the degree of radionuclide distribution of each voxel in the SPECT images. The total effective volume was defined as the sum of the local effective volume, and the residual effective volume was the total effective volume excluding loss after operation. Predicted pulmonary function (VC and FEV 1.0) was calculated by the following formula: Predicted value=preoperative value x percent of the residual effective volume. Postoperative pulmonary function was predicted in the same patients by means of 99m Tc-MAA perfusion lung planar scintigraphy and X-ray CT. The patients were reinvestigated with spirometry at one and four months after surgery, and the values were compared with the predicted values. The correlations between the predicted values using SPECT and measured postoperative pulmonary function were highly significant (VC: r=0.867, FEV1.0: r=0.864 one month after operation; VC: r=0.860, FEV1.0: r=0.907 4 months after operation). The predicted values calculated using SPECT were accurate compared with the predicted values calculated using planar scintigraphy or X-ray CT. The patients with predicted FEV1.0 of less than 0.8 liter required home oxygen therapy. This method is valuable for the prediction of postoperative pulmonary function before the surgical procedure. (author)

  18. Impact of CT perfusion imaging on the assessment of peripheral chronic pulmonary thromboembolism: clinical experience in 62 patients.

    Science.gov (United States)

    Le Faivre, Julien; Duhamel, Alain; Khung, Suonita; Faivre, Jean-Baptiste; Lamblin, Nicolas; Remy, Jacques; Remy-Jardin, Martine

    2016-11-01

    To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. • Dual-energy computed tomography generates standard diagnostic imaging and lung perfusion analysis. • Depiction of CPE on central arteries relies on standard diagnostic imaging. • Detection of peripheral CPE is improved by perfusion imaging.

  19. CT perfusion of the liver during selective hepatic arteriography. Pure arterial blood perfusion of liver tumor and parenchyma

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Kojima, Hiroyuki; Kariya, Shuji; Sawada, Satoshi

    2003-01-01

    The purpose of this study was to quantify pure arterial blood perfusion of liver tumor and parenchyma by using CT perfusion during selective hepatic arteriography. A total of 44 patients underwent liver CT perfusion study by injection of contrast medium via the hepatic artery. CT-perfusion parameters including arterial blood flow, arterial blood volume, and arterial mean transit time in the liver parenchyma and liver tumor were calculated using the deconvolution method. The CT-perfusion parameters and vascularity of the tumor were compared. A complete analysis could be performed in 36 of the 44 patients. For liver tumor and liver parenchyma, respectively, arterial blood flow was 184.6±132.7 and 41.0±27.0 ml/min/100 g, arterial blood volume was 19.4±14.6 and 4.8±4.2 ml/100 g, and arterial mean transit time was 8.9±4.2 and 10.2±5.3 sec. Arterial blood flow and arterial blood volume correlated significantly with the vascularity of the tumor; however no correlation was detected between arterial mean transit time and the vascularity of the tumor. This technique could be used to quantify pure hepatic arterial blood perfusion. (author)

  20. Lung perfusion SPECT in predicting postoperative pulmonary function in lung cancer

    International Nuclear Information System (INIS)

    Hirose, Yoshiaki; Imaeda, Takeyoshi; Doi, Hidetaka; Kokubo, Mitsuharu; Sakai, Satoshi; Hirose, Hajime

    1993-01-01

    The aim of this prospective study is to evaluate the availability of preoperative perfusion SPECT in predicting postoperative pulmonary function following resection. Twenty-three patients with lung cancer who were candidates for lobectomy were investigated preoperatively with spirometry, x-ray computed tomography and 99m Tc-macroaggregated albumin SPECT. Their postoperative pulmonary functions were predicted with these examinations. The forced vital capacity and the forced expiratory volume in one second were selected as parameters for overall pulmonary function. The postoperative pulmonary function was predicted by the following formula: Predicted postoperative value=observed preoperative value x precent perfusion of the lung not to be resected. The patients were reinvestigated with spirometry at 3 months and 6 months after lobectomy, and the values obtained were statistically compared with the predicted values. Close relationships were found between predicted and observed forced vital capacity (r=0.87, p<0.001), and predicted and observed forced expiratory volume in one second (r=0.90, p<0.001). The accurate prediction of pulmonary function after lobectomy could be achieved by means of lung perfusion SPECT. (author)

  1. Improved visualization of delayed perfusion in lung MRI

    International Nuclear Information System (INIS)

    Risse, Frank; Eichinger, Monika; Kauczor, Hans-Ulrich; Semmler, Wolfhard; Puderbach, Michael

    2011-01-01

    Introduction: The investigation of pulmonary perfusion by three-dimensional (3D) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was proposed recently. Subtraction images are generated for clinical evaluation, but temporal information is lost and perfusion defects might therefore be masked in this process. The aim of this study is to demonstrate a simple analysis strategy and classification for 3D-DCE-MRI perfusion datasets in the lung without omitting the temporal information. Materials and methods: Pulmonary perfusion measurements were performed in patients with different lung diseases using a 1.5 T MR-scanner with a time-resolved 3D-GRE pulse sequence. 25 3D-volumes were acquired after iv-injection of 0.1 mmol/kg KG Gadolinium-DTPA. Three parameters were determined for each pixel: (1) peak enhancement S n,max normalized to the arterial input function to detect regions of reduced perfusion; (2) time between arterial peak enhancement in the large pulmonary artery and tissue peak enhancement τ to visualize regions with delayed bolus onset; and (3) ratio R = S n,max /τ was calculated to visualize impaired perfusion, irrespectively of whether related to reduced or delayed perfusion. Results: A manual selection of peak perfusion images is not required. Five different types of perfusion can be found: (1) normal perfusion; (2) delayed non-reduced perfusion; (3) reduced non-delayed perfusion; (4) reduced and delayed perfusion; and (5) no perfusion. Types II and IV could not be seen in subtraction images since the temporal information is necessary for this purpose. Conclusions: The analysis strategy in this study allows for a simple and observer-independent visualization and classification of impaired perfusion in dynamic contrast-enhanced pulmonary perfusion MRI by using the temporal information of the datasets.

  2. CT perfusion scanning of the brain in stroke and beyond

    International Nuclear Information System (INIS)

    Riedel, Christian

    2011-01-01

    CT perfusion scanning (CTP) allows for quantitative analysis of cerebral blood flow (CBF) and cerebral blood volume (CBV). Until recently, it was only possible to study brain perfusion parameters in a small stack of CT-slices close to the skull base. With the introduction of multidetector CT scanners with 64 and more detector rows it has become possible to assess perfusion of the entire brain. An optimal choice of scanning parameters like the new 'shuttle'-technique combined with a well adapted regimen for contrast administration is required to guarantee reliable perfusion measurements while still keeping the X-ray dose absorbed by the patient at a minimum. With these techniques, CTP is not only an important modality in the work-up of patients suffering from acute ischemic stroke but can also be valuable in other emergency situations such as in prolonged epileptic seizures or to monitor patients with subacute subarachnoid hemorrhage. (orig.)

  3. Local cortical hypoperfusion imaged with CT perfusion during postictal Todd's paresis

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, Marlon S.; Binder, Devin K. [University of California, Department of Neurological Surgery, Irvine, CA (United States); Smith, Wade S. [University of California, Department of Neurology, San Francisco, CA (United States); Wintermark, Max; Dillon, William P. [University of California, Department of Radiology, San Francisco, CA (United States)

    2008-05-15

    Postictal ('Todd's') paralysis, or 'epileptic hemiplegia,' is a well-known complication of focal or generalized epileptic seizures. However, it is unclear whether the pathophysiology of Todd's paralysis is related to alterations in cerebral perfusion. We report CT perfusion findings in a patient presenting with postictal aphasia and right hemiparesis. A 62-year-old woman with a history of alcohol abuse, closed head injury and posttraumatic epilepsy, presented with acute onset aphasia and right hemiparesis. A non-contrast head CT scan demonstrated no acute hemorrhage. Left hemispheric ischemia was suspected, and the patient was considered for acute thrombolytic therapy. MRI revealed a subtle increase in signal intensity involving the left medial temporal, hippocampal and parahippocampal regions on both T2-weighted FLAIR and diffusion-weighted sequences. CT angiography and CT perfusion study were performed. The CT perfusion study and CT angiography demonstrated a dramatic reduction in cerebral blood flow and blood volume involving the entire left hemisphere, but with relative symmetry of mean transit time, ruling out a large vessel occlusion. Clinical resolution of the aphasia and hemiparesis occurred within a few hours, and correlated with normalization of perfusion to the left hemisphere (detected by MR perfusion). This unique case is the first in which clinical evidence of Todd's paralysis has been correlated with reversible postictal hemispheric changes on CT and MR perfusion studies. This is important because CT perfusion study is being used more and more in the diagnosis of acute stroke, and one needs to be careful to not misinterpret the data. (orig.)

  4. Effects of Constant Flow vs. Constant Pressure Perfusion on Fluid Filtration in Severe Hypothermic Isolated Blood-Perfused Rat Lungs.

    Science.gov (United States)

    Halsøy, Kathrine; Kondratiev, Timofey; Tveita, Torkjel; Bjertnaes, Lars J

    2016-01-01

    Victims of severe accidental hypothermia are prone to fluid extravasation but rarely develop lung edema. We hypothesize that combined hypothermia-induced increase in pulmonary vascular resistance (PVR) and a concomitant fall in cardiac output protect the lungs against edema development. Our aim was to explore in hypothermic-isolated blood-perfused rat lungs whether perfusion at constant pressure influences fluid filtration differently from perfusion at constant flow. Isolated blood-perfused rat lungs were hanging freely in a weight transducer for measuring weight changes (ΔW). Fluid filtration coefficient (Kfc), was determined by transiently elevating left atrial pressure (Pla) by 5.8 mmHg two times each during normothermia (37°C) and during hypothermia (15°C). The lung preparations were randomized to two groups. One group was perfused with constant flow (Constant flow group) and the other group with constant pulmonary artery pressure (Constant PPA group). Microvascular pressure (Pmv) was determined before and during elevation of Pla (ΔPmv) by means of the double occlusion technique. Kfc was calculated with the formula Kfc = ΔW/ΔPmv/min. All Kfc values were normalized to predicted lung weight (P LW ), which was based on body weight (BW) according to the formula: P LW  = 0.0053 BW - 0.48 and presented as Kfc PLW in mg/min/mmHg/g. At cessation, bronchoalveolar lavage (BAL) fluid/perfusate protein concentration (B/P) ratio was determined photometrically. Data were analyzed with parametric or non-parametric tests as appropriate. p  Kfc PLW and B/P ratio increased significantly by more than 10-fold during hypothermia concerted by visible signs of edema in the trachea. Hemoglobin and hematocrit increased within the Constant flow group and between the groups at cessation of the experiments. In hypothermic rat lungs perfused at constant flow, fluid filtration coefficient per gram P LW and B/P ratio increased more than 10-fold concerted by increased

  5. Lung cancer mimicking lung abscess formation on CT images.

    Science.gov (United States)

    Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi

    2014-01-01

    Male, 64 FINAL DIAGNOSIS: Lung pleomorphic carcinoma Symptoms: Cough • fever - Clinical Procedure: - Specialty: Oncology. Unusual clinical course. The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resembled a lung abscess on CT. We herein describe the case of 64-year-old male who was diagnosed with lung cancer using surgery. In this case, it was quite difficult to distinguish between the lung cancer and a lung abscess on CT images, and a lung abscess was initially suspected due to symptoms, such as fever and coughing, contrast-enhanced CT image findings showing a ring-enhancing mass in the right upper lobe and the patient's laboratory test results. However, a pathological diagnosis of lung cancer was confirmed according to the results of a rapid frozen section biopsy of the lesion. This case suggests that physicians should not suspect both a lung abscesses and malignancy in cases involving masses presenting as ring-enhancing lesions on contrast-enhanced CT.

  6. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    International Nuclear Information System (INIS)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J.; Higashigaito, Kai; Jung, Andreas

    2018-01-01

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  7. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J. [University Children' s Hospital Zuerich, Department of Diagnostic Imaging, Zuerich, CH (Switzerland); University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); Higashigaito, Kai [University Hospital Zuerich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Jung, Andreas [University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); University Children' s Hospital Zuerich, Division of Pneumology, Zuerich (Switzerland)

    2018-02-15

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  8. Powerful functional imaging of respiratory nuclear medicine. Is CT imaging alone really sufficient for diagnosis and pathophysiologic assessment of lung diseases?

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2010-01-01

    Ventilation (V)-perfusion (Q) single photon emission computed tomography (SPECT) provides important information of functional impairment in various lung diseases, and often sensitively detects CT-undetectable lesions. V·Q SPECT also provides objective and quantitative assessment of severity of lung functional impairment. Functional-morphological correlation on V·Q SPECT-CT fusion images further facilitates these advantages of V·Q SPECT. This article describes clinical feasibility of V·Q SPECT in functional assessment and diagnosis of chronic obstructive pulmonary diseases, pulmonary embolism, pulmonary hypertension, interstitial lung diseases, and lung right-to-left shunt diseases. This article hopefully provides sufficient responses to the crucial query of ''Is CT imaging alone really sufficient for diagnosis and pathophysiological assessment of various lung diseases?'' (author)

  9. The utility of first-pass perfusion CT in hyperacute ischemic stroke: early experience

    International Nuclear Information System (INIS)

    Lee, Tae Jin; Lee, Myeong Sub; Kim, Myung Soon; Hong, In Soo; Lee, Young Han; Lee, Ji Yong; Whang, Kum

    2003-01-01

    To evaluate the findings of first-pass perfusion CT in hyperacute stroke patients and to determine the relationship between a perfusion map and final infarct outcome. Thirty-five patients admitted with ischemic stroke within six hours of the onset of symptoms underwent conventional cerebral CT immediately followed by first-pass perfusion CT. Nineteen underwent follow-up CT or MRI, and three types of dynamic perfusion map-cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) - were evaluated by two radiologists. In these 19 patients, initial perfusion maps correlated with final infarct size, determined during follow-up studies. In all 35 patients, major large vessel perfusion abnormalities [middle cerebral artery - MCA MCA and anterior cerebral artery - ACA (n=2); posterior cerebral artery - PCA (n=8)] were detected. On first-pass perfusion maps depicting CBF and MTT, all lesions were detected, and CBF and delayed MTT values were recorded. CBV maps showed variable findings. In all 19 patients who were followed up, the final infarct size of perfusion abnormalities was less than that depicted on CBF and MTT maps, and similar to or much greater than that seen on CBV maps. First-pass perfusion CT scanning is a practical, rapid and advanced imaging technique. In hyperacute stroke patients, it provides important and reliable hemodynamic information as to which brain tissue is salvageable by thrombolytic therapy, and predicts outcome of such treatment

  10. Diagnosis of renal perfusion abnormalities by sequential CT

    Energy Technology Data Exchange (ETDEWEB)

    Treugut, H; Andersson, I; Hildell, J; Nyman, U; Weibull, H

    1981-10-01

    Abnormalities of renal perfusion can be recognised more readily by sequential CT than by plain CT scan or after static enhancement with contrast medium. Haemodynamically significant stenoses of the renal arteries and total, or partial, infarcts can be diagnosed in this way. Intrarenal and capsular collaterals can be recognised by slow contrast accumulation in the infarcted area, or by the development of contrast in the sub-capsular portion of the cortex. Renal cortical necrosis is very well demonstrated by the absence of cortical perfusion; this is seen, for instance, in the DIC syndrome or during rejection after renal transplant.

  11. Dual-energy perfusion-CT in recurrent pancreatic cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, F.; Skornitzke, S.; Kauczor, H.U.; Stiller, W.; Klauss, M. [Heidelberg Univ. (Germany). Clinic of Diagnostic and Interventional Radiology; Hackert, T. [Heidelberg Univ. (Germany). Clinic of Surgery; Grenacher, L. [Diagnostik Muenchen (Germany). Diagnostic Imaging Center

    2016-06-15

    To evaluate the diagnostic performance of dual energy (DE) perfusion-CT for the differentiation between postoperative soft-tissue formation and tumor recurrence in patients after potentially curative pancreatic cancer resection. 24 patients with postoperative soft-tissue formation in the conventional regular follow-up CT acquisition after pancreatic cancer resection with curative intent were included prospectively. They were examined with a 64-row dual-source CT using a dynamic sequence of 34 DE acquisitions every 1.5 s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). Weighted average (linearly blended M0.5) 120 kVp-equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool for estimating blood flow, permeability, and blood volume. Diagnosis was confirmed by histological study (n=4) and by regular follow-up. Final diagnosis was local recurrence of pancreatic cancer in 15 patients and unspecific postoperative tissue formation in 9 patients. The blood-flow values for recurrence tissue trended to be lower compared to postoperative tissue formation with 16.6 ml/100 ml/min and 24.7 ml/100 ml/min, respectively for weighted average 120 kVp-equivalent image data, which was not significant (n.s.) (p=0.06, significance level 0.05). Permeability- and blood-volume values were only slightly lower in recurrence tissue (n.s.). DE perfusion-CT is feasible in patients after pancreatic cancer resection and a promising functional imaging technique. As only a trend for lower perfusion values in local recurrence compared to unspecific postoperative alterations was found, the perfusion differences are not yet sufficient to differentiate between malignancy and unspecific postoperative alterations for this new technique. Further studies and technical improvements are needed to generate reliable data for this clinically highly relevant differentiation.

  12. Ex vivo lung perfusion with adenosine A2A receptor agonist allows prolonged cold preservation of lungs donated after cardiac death.

    Science.gov (United States)

    Wagner, Cynthia E; Pope, Nicolas H; Charles, Eric J; Huerter, Mary E; Sharma, Ashish K; Salmon, Morgan D; Carter, Benjamin T; Stoler, Mark H; Lau, Christine L; Laubach, Victor E; Kron, Irving L

    2016-02-01

    Ex vivo lung perfusion has been successful in the assessment of marginal donor lungs, including donation after cardiac death (DCD) donor lungs. Ex vivo lung perfusion also represents a unique platform for targeted drug delivery. We sought to determine whether ischemia-reperfusion injury would be decreased after transplantation of DCD donor lungs subjected to prolonged cold preservation and treated with an adenosine A2A receptor agonist during ex vivo lung perfusion. Porcine DCD donor lungs were preserved at 4°C for 12 hours and underwent ex vivo lung perfusion for 4 hours. Left lungs were then transplanted and reperfused for 4 hours. Three groups (n = 4/group) were randomized according to treatment with the adenosine A2A receptor agonist ATL-1223 or the dimethyl sulfoxide vehicle: Infusion of dimethyl sulfoxide during ex vivo lung perfusion and reperfusion (DMSO), infusion of ATL-1223 during ex vivo lung perfusion and dimethyl sulfoxide during reperfusion (ATL-E), and infusion of ATL-1223 during ex vivo lung perfusion and reperfusion (ATL-E/R). Final Pao2/Fio2 ratios (arterial oxygen partial pressure/fraction of inspired oxygen) were determined from samples obtained from the left superior and inferior pulmonary veins. Final Pao2/Fio2 ratios in the ATL-E/R group (430.1 ± 26.4 mm Hg) were similar to final Pao2/Fio2 ratios in the ATL-E group (413.6 ± 18.8 mm Hg), but both treated groups had significantly higher final Pao2/Fio2 ratios compared with the dimethyl sulfoxide group (84.8 ± 17.7 mm Hg). Low oxygenation gradients during ex vivo lung perfusion did not preclude superior oxygenation capacity during reperfusion. After prolonged cold preservation, treatment of DCD donor lungs with an adenosine A2A receptor agonist during ex vivo lung perfusion enabled Pao2/Fio2 ratios greater than 400 mm Hg after transplantation in a preclinical porcine model. Pulmonary function during ex vivo lung perfusion was not predictive of outcomes after transplantation. Copyright

  13. Magnetic Resonance Imaging of Ventilation and Perfusion in the Lung

    Science.gov (United States)

    Prisk, Gordon Kim (Inventor); Hopkins, Susan Roberta (Inventor); Buxton, Richard Bruce (Inventor); Pereira De Sa, Rui Carlos (Inventor); Theilmann, Rebecca Jean (Inventor); Cronin, Matthew Vincent (Inventor)

    2017-01-01

    Methods, devices, and systems are disclosed for implementing a fully quantitative non-injectable contrast proton MRI technique to measure spatial ventilation-perfusion (VA/Q) matching and spatial distribution of ventilation and perfusion. In one aspect, a method using MRI to characterize ventilation and perfusion in a lung includes acquiring an MR image of the lung having MR data in a voxel and obtaining a breathing frequency parameter, determining a water density value, a specific ventilation value, and a perfusion value in at least one voxel of the MR image based on the MR data and using the water density value to determine an air content value, and determining a ventilation-perfusion ratio value that is the product of the specific ventilation value, the air content value, the inverse of the perfusion value, and the breathing frequency.

  14. CT perfusion imaging in response assessment of pulmonary metastases undergoing stereotactic ablative radiotherapy

    International Nuclear Information System (INIS)

    Sawyer, Brooke; Pun, Emma; Tay, Huilee; Kron, Tomas; Bressel, Mathias; Ball, David; Siva, Shankar; Samuel, Michael

    2015-01-01

    Stereotactic ablative body radiotherapy (SABR) is an emerging treatment technique for pulmonary metastases in which conventional Response Evaluation Criteria in Solid Tumours (RECIST) may be inadequate. This study aims to assess the utility of CT perfusion imaging in response assessment of pulmonary metastases after SABR. In this ethics board-approved prospective study, 11 patients underwent a 26-Gy single fraction of SABR to pulmonary metastases. CT perfusion imaging occurred prior to and at 14 and 70 days post-SABR. Blood flow (mL/100 mL/min), blood volume (mL/100 mL), time to peak (seconds) and surface permeability (mL/100 mL/min), perfusion parameters of pulmonary metastases undergoing SABR, were independently assessed by two radiologists. Inter-observer variability was analysed. CT perfusion results were analysed for early response assessment comparing day 14 with baseline scans and for late response by comparing day 70 with baseline scans. The largest diameter of the pulmonary metastases undergoing SABR was recorded. Ten patients completed all three scans and one patient had baseline and early response assessment CT perfusion scans only. There was strong level of inter-observer agreement of CT perfusion interpretation with a median intraclass coefficient of 0.87 (range 0.20–0.98). Changes in all four perfusion parameters and tumour sizes were not statistically significant. CT perfusion imaging of pulmonary metastases is a highly reproducible imaging technique that may provide additional response assessment information above that of conventional RECIST, and it warrants further study in a larger cohort of patients undergoing SABR.

  15. Kinetics of reversible-sequestration of leukocytes by the isolated perfused rat lung

    Energy Technology Data Exchange (ETDEWEB)

    Goliaei, B.

    1980-08-01

    The kinetics and morphology of sequestration and margination of rat leukocytes were studied using an isolated perfused and ventilated rat lung preparation. Whole rat blood, bone marrow suspension, or leukocyte suspensions, were used to perfuse the isolated rat lung. The lung was also perfused with latex particle suspensions and the passage of particles through the lung capillaries was studied. When a leukocyte suspension was perfused through the lung in the single-pass mode, the rate of sequestration decreased as more cells were perfused. In contrast, latex particles of a size comparable to that of leukocytes were totally stopped by the lung. When the leukocyte suspension was recirculated through the lung, cells were rapidly removed from circulation until a steady state was reached, after which no net removal of cells by the lung occurred. These results indicate that leukocytes are reversibly sequestered from circulation. The sequestered cells marginated and attached to the luminal surface of the endothelium of post-capillary venules and veins. A mathematical model was developed based on the assumption that the attachment and detachment of leukocytes to blood vessel walls follows first-order kinetics. The model correctly predicts the following characteristics of the system: (a) the kinetics of the sequestration of leukocytes by the lung; (b) the existence of a steady state when a suspension of leukocytes is recirculated through the lung; and (c) the independence of the fraction of cells remaining in circulation from the starting concentration for all values of starting concentration. (ERB)

  16. CT perfusion imaging in the management of posterior reversible encephalopathy

    International Nuclear Information System (INIS)

    Casey, S.O.; McKinney, A.; Teksam, M.; Liu, H.; Truwit, C.L.

    2004-01-01

    A 13-year-old girl with a renal transplant presented with hypertension and seizures. CT and MRI demonstrated typical bilateral parietal, occipital and posterior frontal cortical and subcortical edema, thought to represent posterior reversible encephalopathy syndrome. The cause was presumed to be hypertension. Antihypertensive therapy was started, lowering of the blood pressure in the range of 110-120 mmHg systolic. However, stable xenon (Xe) CT perfusion imaging revealed ischemia within the left parietal occipital region. The antihypertensive was adjusted which increased both the systolic and diastolic blood pressure by 31 mm Hg. The patient was re-imaged with Xe CT and was found to have resolution of the ischemic changes within the left parietal occipital region. In this report, we present a case in which stable Xe CT was used to monitor the degree of cerebral perfusion and guide titration of antihypertensive therapy. Such brain perfusion monitoring may have helped to prevent infarction of our patient. (orig.)

  17. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    International Nuclear Information System (INIS)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi; Morikage, Noriyasu; Sano, Yuichi; Suga, Kazuyoshi

    2013-01-01

    Background: Dual-energy perfusion CT (DE p CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE p CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE p CT using a 64-slice dual-source CT. DE p CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V 120 ), 1-15 HU (V 15 ), 1-10 HU (V 10 ), and 1-5 HU (V 5 ). Each relative ratio per V 120 was expressed as the %V 15 , %V 10 , and %V 5 . Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V 15 , V 10 , V 5 , %V 15 , %V 10 , and %V 5 were also significantly higher than those without IPC (P = 0.001). %V 5 had a better correlation with D-dimer (r = 0.30, P p CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE

  18. Brain perfusion-CT in acute stroke patients

    International Nuclear Information System (INIS)

    Wintermark, M.

    2005-01-01

    The role of neuro-imaging in the evaluation of acute stroke has changed dramatically in the past decade. Previously, neuro-imaging was used in this setting to provide anatomic imaging that indicated the presence or absence of acute cerebral ischemia and excluded lesions that produce symptoms or signs mimicking those of stroke, such as hemorrhage and neoplasms. More recently, the introduction of thrombolysis has changed the goals of neuro-imaging from providing solely anatomic information to providing physiologic information that could help to determine which patients might benefit from therapy. In particular, significant emphasis has been placed on the delineation of the ischemic penumbra, also called tissue at risk. Modern CT survey, consisting of three indissociable elements: noncontrast CT (NCT) of course, perfusion-CT (PCT) and CT-angiography (CTA), fulfill all the requirements for hyper-acute stroke imaging. CTA can define the occlusion site, depict arterial dissection, grade collateral blood flow, and characterize atherosclerotic disease, whereas PCT accurately delineates the infarct core and the ischemic penumbra. CT offers a number of practical advantages over other cerebral perfusion imaging methods, including its wide availability. Using PCT and CTA to define new individualized strategies for acute reperfusion will allow more acute stroke patients to benefit from thrombolytic therapy. (orig.)

  19. Histogram based analysis of lung perfusion of children after congenital diaphragmatic hernia repair.

    Science.gov (United States)

    Kassner, Nora; Weis, Meike; Zahn, Katrin; Schaible, Thomas; Schoenberg, Stefan O; Schad, Lothar R; Zöllner, Frank G

    2018-05-01

    To investigate a histogram based approach to characterize the distribution of perfusion in the whole left and right lung by descriptive statistics and to show how histograms could be used to visually explore perfusion defects in two year old children after Congenital Diaphragmatic Hernia (CDH) repair. 28 children (age of 24.2±1.7months; all left sided hernia; 9 after extracorporeal membrane oxygenation therapy) underwent quantitative DCE-MRI of the lung. Segmentations of left and right lung were manually drawn to mask the calculated pulmonary blood flow maps and then to derive histograms for each lung side. Individual and group wise analysis of histograms of left and right lung was performed. Ipsilateral and contralateral lung show significant difference in shape and descriptive statistics derived from the histogram (Wilcoxon signed-rank test, phistogram derived parameters. Histogram analysis can be a valuable tool to characterize and visualize whole lung perfusion of children after CDH repair. It allows for several possibilities to analyze the data, either describing the perfusion differences between the right and left lung but also to explore and visualize localized perfusion patterns in the 3D lung volume. Subgroup analysis will be possible given sufficient sample sizes. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Simulation evaluation of quantitative myocardial perfusion assessment from cardiac CT

    Science.gov (United States)

    Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.

    2014-03-01

    Contrast enhancement on cardiac CT provides valuable information about myocardial perfusion and methods have been proposed to assess perfusion with static and dynamic acquisitions. There is a lack of knowledge and consensus on the appropriate approach to ensure 1) sufficient diagnostic accuracy for clinical decisions and 2) low radiation doses for patient safety. This work developed a thorough dynamic CT simulation and several accepted blood flow estimation techniques to evaluate the performance of perfusion assessment across a range of acquisition and estimation scenarios. Cardiac CT acquisitions were simulated for a range of flow states (Flow = 0.5, 1, 2, 3 ml/g/min, cardiac output = 3,5,8 L/min). CT acquisitions were simulated with a validated CT simulator incorporating polyenergetic data acquisition and realistic x-ray flux levels for dynamic acquisitions with a range of scenarios including 1, 2, 3 sec sampling for 30 sec with 25, 70, 140 mAs. Images were generated using conventional image reconstruction with additional image-based beam hardening correction to account for iodine content. Time attenuation curves were extracted for multiple regions around the myocardium and used to estimate flow. In total, 2,700 independent realizations of dynamic sequences were generated and multiple MBF estimation methods were applied to each of these. Evaluation of quantitative kinetic modeling yielded blood flow estimates with an root mean square error (RMSE) of ~0.6 ml/g/min averaged across multiple scenarios. Semi-quantitative modeling and qualitative static imaging resulted in significantly more error (RMSE = ~1.2 and ~1.2 ml/min/g respectively). For quantitative methods, dose reduction through reduced temporal sampling or reduced tube current had comparable impact on the MBF estimate fidelity. On average, half dose acquisitions increased the RMSE of estimates by only 18% suggesting that substantial dose reductions can be employed in the context of quantitative myocardial

  1. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  2. Comparison of lung preservation solutions in human lungs using an ex vivo lung perfusion experimental model

    Directory of Open Access Journals (Sweden)

    Israel L. Medeiros

    2012-09-01

    Full Text Available OBJECTIVE: Experimental studies on lung preservation have always been performed using animal models. We present ex vivo lung perfusion as a new model for the study of lung preservation. Using human lungs instead of animal models may bring the results of experimental studies closer to what could be expected in clinical practice. METHOD: Brain-dead donors whose lungs had been declined by transplantation teams were used. The cases were randomized into two groups. In Group 1, Perfadex®was used for pulmonary preservation, and in Group 2, LPDnac, a solution manufactured in Brazil, was used. An ex vivo lung perfusion system was used, and the lungs were ventilated and perfused after 10 hours of cold ischemia. The extent of ischemic-reperfusion injury was measured using functional and histological parameters. RESULTS: After reperfusion, the mean oxygenation capacity was 405.3 mmHg in Group 1 and 406.0 mmHg in Group 2 (p = 0.98. The mean pulmonary vascular resistance values were 697.6 and 378.3 dyn·s·cm-5, respectively (p =0.035. The mean pulmonary compliance was 46.8 cm H20 in Group 1 and 49.3 ml/cm H20 in Group 2 (p =0.816. The mean wet/dry weight ratios were 2.06 and 2.02, respectively (p=0.87. The mean Lung Injury Scores for the biopsy performed after reperfusion were 4.37 and 4.37 in Groups 1 and 2, respectively (p = 1.0, and the apoptotic cell counts were 118.75/mm² and 137.50/mm², respectively (p=0.71. CONCLUSION: The locally produced preservation solution proved to be as good as Perfadex®. The clinical use of LPDnac may reduce costs in our centers. Therefore, it is important to develop new models to study lung preservation.

  3. Role of radio-aerosol and perfusion lung imaging in early detection of chronic obstructive lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Garg, A; Pande, J N; Guleria, J S; Gopinath, P G

    1983-04-01

    The efficacy of radio-aerosol and perfusion lung imaging in the early detection of chronic obstructive lung disease was evaluated in 38 subjects. The subjects included 5 non-smokers, 21 smokers with minimal or no respiratory symptoms and 12 patients with chronic obstructive lung disease. Each subject consented to a respiratory questionaire, detailed physical examination, chest X-ray examinations, detailed pulmonary function tests and sup(99m)Tc-radioaerosol-inhalation lung imaging. Perfusion lung imaging with sup(99m)Tc-labelled macroaggregated albumin was performed in 22 subjects. A significant correlation (P<0.001) was observed between the degree of abnormalities on radio-aerosol imaging and pulmonary function tests (PFTs) including forced expiratory volume in 1 s, maximum midexpiratory flow rate and mean transit time analysis. Abnormal radio-aerosol patterns and deranged PFTs were observed in 21 subjects each. Of 21 subjects with abnormal radioaerosol pattern 8 had normal PFTs. Of 21 subjects with abnormal PFTs 8 had normal aerosol images. Aerosol lung images and PFTs were abnormal more frequently than perfusion lung images. The results suggest that radio-aerosol lung imaging is as sensitive an indicator as PFTs for early detection of chronic obstructive lung disease and can be usefully combined with PFTs for early detection of alteration in pulmonary physiology in smokers.

  4. Dynamic contrast-enhanced perfusion area-detector CT assessed with various mathematical models: Its capability for therapeutic outcome prediction for non-small cell lung cancer patients with chemoradiotherapy as compared with that of FDG-PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Fujisawa, Yasuko [Toshiba Medical Systems Corporation, Otawara (Japan); Koyama, Hisanobu; Kishida, Yuji; Seki, Shinichiro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan)

    2017-01-15

    Purpose: To directly compare the capability of dynamic first-pass contrast-enhanced (CE-) perfusion area-detector CT (ADCT) and PET/CT for early prediction of treatment response, disease progression and overall survival of non-small cell carcinoma (NSCLC) patients treated with chemoradiotherapy. Materials and methods: Fifty-three consecutive Stage IIIB NSCLC patients who had undergone PET/CT, dynamic first-pass CE-perfusion ADCT, chemoradiotherapy, and follow-up examination were enrolled in this study. They were divided into two groups: 1) complete or partial response (CR + PR) and 2) stable or progressive disease (SD + PD). Pulmonary arterial and systemic arterial perfusions and total perfusion were assessed at targeted lesions with the dual-input maximum slope method, permeability surface and distribution volume with the Patlak plot method, tumor perfusion with the single-input maximum slope method, and SUV{sub max}, and results were averaged to determine final values for each patient. Next, step-wise regression analysis was used to determine which indices were the most useful for predicting therapeutic effect. Finally, overall survival of responders and non-responders assessed by using the indices that had a significant effect on prediction of therapeutic outcome was statistically compared. Results: The step-wise regression test showed that therapeutic effect (r{sup 2} = 0.63, p = 0.01) was significantly affected by the following three factors in order of magnitude of impact: systemic arterial perfusion, total perfusion, and SUV{sub max}. Mean overall survival showed a significant difference for total perfusion (p = 0.003) and systemic arterial perfusion (p = 0.04). Conclusion: Dynamic first-pass CE-perfusion ADCT as well as PET/CT are useful for treatment response prediction in NSCLC patients treated with chemoradiotherapy.

  5. Dynamic contrast-enhanced perfusion area-detector CT assessed with various mathematical models: Its capability for therapeutic outcome prediction for non-small cell lung cancer patients with chemoradiotherapy as compared with that of FDG-PET/CT

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Koyama, Hisanobu; Kishida, Yuji; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi

    2017-01-01

    Purpose: To directly compare the capability of dynamic first-pass contrast-enhanced (CE-) perfusion area-detector CT (ADCT) and PET/CT for early prediction of treatment response, disease progression and overall survival of non-small cell carcinoma (NSCLC) patients treated with chemoradiotherapy. Materials and methods: Fifty-three consecutive Stage IIIB NSCLC patients who had undergone PET/CT, dynamic first-pass CE-perfusion ADCT, chemoradiotherapy, and follow-up examination were enrolled in this study. They were divided into two groups: 1) complete or partial response (CR + PR) and 2) stable or progressive disease (SD + PD). Pulmonary arterial and systemic arterial perfusions and total perfusion were assessed at targeted lesions with the dual-input maximum slope method, permeability surface and distribution volume with the Patlak plot method, tumor perfusion with the single-input maximum slope method, and SUV max , and results were averaged to determine final values for each patient. Next, step-wise regression analysis was used to determine which indices were the most useful for predicting therapeutic effect. Finally, overall survival of responders and non-responders assessed by using the indices that had a significant effect on prediction of therapeutic outcome was statistically compared. Results: The step-wise regression test showed that therapeutic effect (r 2 = 0.63, p = 0.01) was significantly affected by the following three factors in order of magnitude of impact: systemic arterial perfusion, total perfusion, and SUV max . Mean overall survival showed a significant difference for total perfusion (p = 0.003) and systemic arterial perfusion (p = 0.04). Conclusion: Dynamic first-pass CE-perfusion ADCT as well as PET/CT are useful for treatment response prediction in NSCLC patients treated with chemoradiotherapy.

  6. Dynamic contrast-enhanced perfusion area-detector CT assessed with various mathematical models: Its capability for therapeutic outcome prediction for non-small cell lung cancer patients with chemoradiotherapy as compared with that of FDG-PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Koyama, Hisanobu; Kishida, Yuji; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi

    2017-01-01

    To directly compare the capability of dynamic first-pass contrast-enhanced (CE-) perfusion area-detector CT (ADCT) and PET/CT for early prediction of treatment response, disease progression and overall survival of non-small cell carcinoma (NSCLC) patients treated with chemoradiotherapy. Fifty-three consecutive Stage IIIB NSCLC patients who had undergone PET/CT, dynamic first-pass CE-perfusion ADCT, chemoradiotherapy, and follow-up examination were enrolled in this study. They were divided into two groups: 1) complete or partial response (CR+PR) and 2) stable or progressive disease (SD+PD). Pulmonary arterial and systemic arterial perfusions and total perfusion were assessed at targeted lesions with the dual-input maximum slope method, permeability surface and distribution volume with the Patlak plot method, tumor perfusion with the single-input maximum slope method, and SUV max , and results were averaged to determine final values for each patient. Next, step-wise regression analysis was used to determine which indices were the most useful for predicting therapeutic effect. Finally, overall survival of responders and non-responders assessed by using the indices that had a significant effect on prediction of therapeutic outcome was statistically compared. The step-wise regression test showed that therapeutic effect (r 2 =0.63, p=0.01) was significantly affected by the following three factors in order of magnitude of impact: systemic arterial perfusion, total perfusion, and SUV max . Mean overall survival showed a significant difference for total perfusion (p=0.003) and systemic arterial perfusion (p=0.04). Dynamic first-pass CE-perfusion ADCT as well as PET/CT are useful for treatment response prediction in NSCLC patients treated with chemoradiotherapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Clinical evaluation of lung rest/stress perfusion scintigraphy in patients with severe emphysema

    International Nuclear Information System (INIS)

    Hadjikostova, Hr.

    1998-01-01

    Volume lung reduction surgery (LVRS) improves lung function and physical tolerance for selected patients with severe pulmonary emphysema by making conditions for developing of the vital parenchyma so far compressed by the emphysema blisters. The aim of this study was to establish the comparative functional information obtained from REST/STRESS lung perfusion tomoscintigraphies for identification of non functional lung tissue. Eleven patients (8 males and 3 females at age 41-60) were examined by two lung perfusions SPECT scintigraphies after intravenous application of 222 MBq 99m Tc-MAA: 1. after 30 min. lying rest and 2. 48 hours later after 6 min. walk test. Comparing the two scintigraphies the following changes in perfusion performance have been established at STRESS examination: increased at six patients (significant at three and slight also at three) and decreased at two. There was no difference between REST and STRESS examinations at 3 patients. Comparative REST/STRESS lung perfusion scintigraphy is important method for screening severe pulmonary patients for LVRS. (author)

  8. Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies

    International Nuclear Information System (INIS)

    Murase, Kenya; Nanjo, Takafumi; Ii, Satoshi; Miyazaki, Shohei; Hirata, Masaaki; Sugawara, Yoshifumi; Kudo, Masayuki; Sasaki, Kousuke; Mochizuki, Teruhito

    2005-01-01

    The purpose of this study was to investigate the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using multi-detector row CT (MDCT). Following the standard CT perfusion study protocol, continuous (cine) scans (1 s/rotation x 60 s) consisting of four 5 mm thick contiguous slices were performed using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. We generated the simulated images with tube currents of 50 mA, 100 mA and 150 mA by adding the corresponding noise to the raw scan data of the original image acquired above using a noise simulation tool. From the original and simulated images, we generated the functional images of cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) in seven patients with cerebrovascular disease, and compared the correlation coefficients (CCs) between the perfusion parameter values obtained from the original and simulated images. The coefficients of variation (CVs) in the white matter were also compared. The CC values deteriorated with decreasing tube current. There was a significant difference between 50 mA and 100 mA for all perfusion parameters. The CV values increased with decreasing tube current. There were significant differences between 50 mA and 100 mA and between 100 mA and 150 mA for CBF. For CBV and MTT, there was also a significant difference between 150 mA and 200 mA. This study will be useful for understanding the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using MDCT, and for selecting the tube current

  9. Relative preservation of peripheral lung function in smoking-related pulmonary emphysema: assessment with {sup 99m}Tc-MAA perfusion and dynamic {sup 133}Xe SPET

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Kazuyoshi; Kume, Norihiko; Matsunaga, Naofumi; Ogasawara, Nobuhiko; Motoyama, Kazumi; Hara, Akiko; Matsumoto, Tsuneo [Department of Radiology, Yamaguchi University School of Medicine, Ube, Yamaguchi (Japan)

    2000-07-01

    In this study the cross-sectional functional differences between the central and peripheral lung in smokers with pulmonary emphysema were evaluated by lung perfusion and dynamic xenon-133 single-photon emission tomography (SPET). The subjects were 81 patients with a long-term smoking history and relatively advanced emphysema, 17 non-smoker patients with non-obstructive lung diseases and six healthy non-smokers. Regional lung functional difference between the peripheral and central lung was assessed in the upper, middle and lower lung zones by technetium-99m macroaggregated albumin SPET and dynamic {sup 133}Xe SPET. The distribution of emphysematous changes was assessed by density-mask computed tomography (CT) images which depicted abnormally low attenuation areas (LAAs) of less than -960 Hounsfield units. Two hundred and eighty-eight (59.2%) lung zones of 63 (77.7%) patients with pulmonary emphysema showed relative preservation of lung function in the peripheral lung, with a curvilinear band of normal perfusion (a stripe sign) and a significantly faster {sup 133}Xe half-clearance time (T{sub 1/2}) than in central lung (P<0.0001). Of these lung zones, 256 (88.8%) showed central-dominant LAA distributions on density-mask CT images, but the remaining 32 zones did not show any regional preference in LAA distribution. Conversely, 117 (24.0%) lung zones of 19 (23.4%) patients showed periphery-dominant perfusion defects and LAA distributions, with significantly prolonged T{sub 1/2} in the peripheral lung area (P<0.0001). The remaining 81 lung zones of the patients with pulmonary emphysema and all the lung zones of the healthy subjects and patients with non-obstructive lung diseases did not show a stripe sign, and no differences were observed in T{sub 1/2} values and LAA distributions between the central and peripheral lung. Relative preservation of peripheral lung function seems to be a characteristic feature in smoking-related pulmonary emphysema, and may indicate a

  10. The diagnosis of renal perfusion abnormalities by sequential CT

    International Nuclear Information System (INIS)

    Treugut, H.; Andersson, I.; Hildell, J.; Nyman, U.; Weibull, H.

    1981-01-01

    Abnormalities of renal perfusion can be recognised more readily by sequential CT than by plain CT scan or after static enhancement with contrast medium. Haemodynamically significant stenoses of the renal arteries and total, or partial, infarcts can be diagnosed in this way. Intrarenal and capsular collaterals can be recognised by slow contrast accumulation in the infarcted area, or by the development of contrast in the sub-capsular portion of the cortex. Renal cortical necrosis is very well demonstrated by the absence of cortical perfusion; this is seen, for instance, in the DIC syndrome or during rejection after renal transplant. (orig.) [de

  11. Dynamic CT of portal hypertensive gastropathy: significance of transient gastric perfusion defect sign

    International Nuclear Information System (INIS)

    Kim, T.U.; Kim, S.; Woo, S.K.; Lee, J.W.; Lee, T.H.; Jeong, Y.J.; Heo, J.

    2008-01-01

    Aim: To evaluate the 'transient gastric perfusion defect' sign as a way of diagnosing portal hypertensive gastropathy (PHG) on multidetector computed tomography (CT). Materials and methods: Ninety-two consecutive patients with cirrhosis underwent three-phase CT and endoscopy. Endoscopy was performed within 3 days of the CT examination. As controls, 92 patients without clinical evidence of chronic liver diseases who underwent CT and endoscopy were enrolled; the findings at endoscopy were used as a reference standard for patients with PHG. Two radiologists who were unaware of the results of the endoscopy retrospectively interpreted the CT images. PHG was diagnosed on dynamic CT if the transient gastric perfusion defect sign was present. The transient gastric perfusion defect was defined as the presence of transient, segmental or subsegmental hypo-attenuating mucosa in the fundus or body of the stomach on hepatic arterial imaging that returned to normal attenuation on portal venous or equilibrium-phase imaging. The frequency of the transient gastric perfusion defect sign was compared between these two groups using Fisher's exact test. The frequency, sensitivity, specificity, positive predictive values, and negative predictive values of the transient gastric perfusion defect sign were also compared between patients with PHG and without PHG in the cirrhosis group. Results: Nine patients of 92 patients with cirrhosis were excluded because of previous procedure or motion artifact; the remaining 83 patients with cirrhosis were evaluated. In the cirrhosis group, 40 (48.1%) of 83 patients showed the transient gastric perfusion defect sign. In the control group, none of the 92 patients showed the transient gastric perfusion defect sign. In the cirrhotic group, the frequency of the transient gastric perfusion defect sign was significantly higher in the patients with PHG (75%, 36/48) than in patients without PHG (11.4%, 4/35). The sensitivity, specificity, positive predictive

  12. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi [Dept. of Radiology, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan)], e-mail: radokada@yamaguchi-u.ac.jp; Morikage, Noriyasu [Medical Bioregulation Dept. of Organ Regulatory Surgery, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan); Sano, Yuichi [Dept. of Radiology, Yamaguchi Univ. Hospital, Yamaguchi (Japan); Suga, Kazuyoshi [Dept. of Radiology, St Hills Hospital, Yamaguchi (Japan)

    2013-07-15

    Background: Dual-energy perfusion CT (DE{sub p}CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE{sub p}CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE{sub p}CT using a 64-slice dual-source CT. DE{sub p}CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V{sub 120}), 1-15 HU (V{sub 15}), 1-10 HU (V{sub 10}), and 1-5 HU (V{sub 5}). Each relative ratio per V{sub 120} was expressed as the %V{sub 15}, %V{sub 10}, and %V{sub 5}. Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V{sub 15}, V{sub 10}, V{sub 5}, %V{sub 15}, %V{sub 10}, and %V{sub 5} were also significantly higher than those without IPC (P = 0.001). %V{sub 5} had a better correlation with D-dimer (r = 0.30, P < 0.001) and RV/LV diameter ratio (r = 0.27, P < 0.001), and showed a higher AUC (0.73) than the other CT measurements. Conclusion: The volumetric evaluation by DE{sub p}CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE.

  13. Experimental study of CT perfusion in hepatitis, hepatic fibrosis and early stage of cirrhosis

    International Nuclear Information System (INIS)

    Guan Sheng; Zhao Weidong; Zhou Kangrong; Peng Weijun; Mao Jian; Tang Feng; Wang Yong; Cao Guang; Sun Fei

    2005-01-01

    Objective: To investigate the value of CT perfusion in the early diagnosis of hepatic diffuse disease. Methods: Fourteen male Wistar rats of control group and 14 of test group at stages of hepatitis, hepatic fibrosis, hepatic cirrhosis which were induced with diethylnitrosamine (DEN), were studied with CT perfusion respectively. CT perfusion data of different stages were compared and pathologic analysis were performed. Results: Density-time curves of CT perfusion were satisfactory and all perfusion data could be obtained. During the period of hepatitis developing into early stage of hepatic cirrhosis, hepatic artery flow (HAF) trended to increase in test group, mean transmit time (MTT) prolonged obviously, blood flow (BF) and volume (BV) declined. While in control group, HAF declined slightly, MTT, BV and BF increased. Statistic analysis showed the differences of HAF and MTT at different stages between control and test groups were significant (P<0.05 ); the differences of BV and BF between hepatitis and hepatic cirrhosis, hepatic fibrosis and early stage of hepatic cirrhosis in test group were significant (P<0.05), but no significant difference between hepatitis and hepatic fibrosis. The corresponding pathologic changes at stage of hepatitis was swelling of hepatic cells; sinusoids cap illarization and deposition of collagen in the extravascular Disse's spaces were the main changes relating to hepatic blood perfusion at stage of fibrosis and early stage of cirrhosis. Conclusion: The method of CT scan can reflect some changes of hepatic blood perfusion in rats with hepatitis, hepatic fibrosis and early stage of cirrhosis. The data of CT perfusion, especially the changes should be valuable for clinical early diagnosis, treatment and follow-up. (authors)

  14. Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients

    Energy Technology Data Exchange (ETDEWEB)

    Kaemena, Andreas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)], E-mail: andreas.kaemena@charite.de; Streitparth, Florian; Grieser, Christian; Lehmkuhl, Lukas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany); Jamil, Basil [Department of Radiotherapy, Charite-Medical University Berlin, Schumannstr. 20/21, D-10117 Berlin (Germany); Wojtal, Katarzyna; Ricke, Jens; Pech, Maciej [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)

    2007-10-15

    Purpose: To assess the influence of different temporal sampling rates on the accuracy of the results from cerebral perfusion CTs in patients with an acute ischemic stroke. Material and methods: Thirty consecutive patients with acute stroke symptoms received a dynamic perfusion CT (LightSpeed 16, GE). Forty millilitres of iomeprol (Imeron 400) were administered at an injection rate of 4 ml/s. After a scan delay of 7 s, two adjacent 10 mm slices at 80 kV and 190 mA were acquired in a cine mode technique with a cine duration of 49 s. Parametric maps for the blood flow (BF), blood volume (BV) and mean transit time (MTT) were calculated for temporal sampling intervals of 0.5, 1, 2, 3 and 4 s using GE's Perfusion 3 software package. In addition to the quantitative ROI data analysis, a visual perfusion map analysis was performed. Results: The perfusion analysis proved to be technically feasible with all patients. The calculated perfusion values revealed significant differences with regard to the BF, BV and MTT, depending on the employed temporal resolution. The perfusion contrast between ischemic lesions and healthy brain tissue decreased continuously at the lower temporal resolutions. The visual analysis revealed that ischemic lesions were best depicted with sampling intervals of 0.5 and 1 s. Conclusion: We recommend a temporal scan resolution of two images per second for the best detection and depiction of ischemic areas.

  15. Assessment of lobar perfusion in smokers according to the presence and severity of emphysema: preliminary experience with dual-energy CT angiography

    International Nuclear Information System (INIS)

    Pansini, Vittorio; Remy-Jardin, Martine; Faivre, Jean-Baptiste; Remy, Jacques; Schmidt, Bernhard; Dejardin-Bothelo, Alexis; Perez, Thierry; Delannoy, Valerie; Duhamel, Alain

    2009-01-01

    The purpose of the study was to assess pulmonary perfusion on a lobar level in smokers using dual-energy computed tomography (CT). Forty-seven smokers and ten non-smokers underwent a dual-energy multi-detector CT angiogram of the chest that allowed automatic quantification of emphysema and determination of the iodine content at the level of the microcirculation (i.e. ''perfusion imaging''). Emphysema was present in 37 smokers and absent in ten smokers. Smokers with an upper lobe predominance of emphysema (n = 8) had: (1) significantly lower attenuation enhancement values in the upper lobes compared with smokers without emphysema; (2) the lobes with the most severe emphysematous changes had a statistically significantly higher percentage of emphysema (p = 0.0001) and lower mean attenuation enhancement values (p = 0.0001) than the ipsilateral lobes with less severe emphysema, matching parenchymal destruction; (3) a correlation was found between the difference in percentage of emphysema between the upper and lower lobes and the difference in attenuation attenuation enhancement values in the corresponding lobes (p = 0.0355; r = -0.54). Regional alterations of lung perfusion can be depicted by dual-energy CT in smokers with predominant emphysema. (orig.)

  16. The effect of irradiation on lung function and perfusion in patients with lung cancer

    International Nuclear Information System (INIS)

    Abratt, Raymond P.; Willcox, Paul A.

    1995-01-01

    Purpose: To prospectively study the changes in lung function in patients with lung carcinoma treated with relatively high doses of irradiation. Methods and Materials: Lung function was assessed prior to and at 6 and 12 months following radiation therapy by a clinical dyspnea score, formal pulmonary function tests (lung volume spirometry and diffusion capacity) as well as an ipsilateral hemithorax lung perfusion scan. Changes in dyspnea score were evaluated by the chi-square and the Fishers exact test. Changes in formal lung function tests were compared with the t-test for dependent data and correlations with the t-test for independent data. Fifty-one patients were entered into the study. There were 42 evaluable patients at 6 months after irradiation and 22 evaluable patients at 12 months after irradiation. Results: A worsening of dyspnea score from 1 to 2, which is clinically acceptable, occurred in 50% or more of patients. However, a dyspnea score of 3, which is a serious complication, developed in only 5% of patients. The diffusion capacity (DLCO) decreased by 14% at 6 months and 12% at 12 months) (p < 0.0001). The forced vital capacity and total lung capacity decreased between 6% and 8% at 6 month and 12 months, which was statistically significant. The forced expiratory volume in 1 s decreased between 2 and 3% at 6 month and 12 months, which was not statistically significant. The ipsilateral hemithorax perfusion decreased by 17 and 20% at 6 and 12 months (p < 0.0001). There was no correlation between the initial hemithorax perfusion, or its decrease at follow up and the decrease in DLCO. Conclusion: Lung irradiation results in some loss of lung function in patients with lung cancer with a projected survival of 6 months or more. The pretreatment DLCO assessment should be useful in predicting clinical tolerance to irradiation

  17. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Y.; Hayashida, K.; Uehara, T.; Shimonagata, T.; Nishimura, T.; Osaka Univ., Suita

    1993-01-01

    15 cases of primary pulmonary hypertension were classified into two groups by patterns of perfusion lung scintigraphy. Perfusion scintigrams showed multiple, small, ill-defined defects (mottled + ve) pattern in eight cases, and the remaining seven cases had a normal (mottled - ve) pattern. The mean pulmonary arterial pressure in patients with a mottled pattern (54 ± 10 mmHg) was higher than in those with a normal pattern (42 ± 9 mmHg, p < 0.05). There were no significant differences between the two groups in right ventricular ejection fraction, partial pressures of oxygen in the arterial blood or alveolo-arterial oxygen difference. All the patients with a mottled pattern died within 2 years following the lung scintigraphy. There was a significant difference in the survival curves between the two groups. (author)

  18. A Simplified Whole-Organ CT Perfusion Technique with Biphasic Acquisition: Preliminary Investigation of Accuracy and Protocol Feasibility in Kidneys.

    Science.gov (United States)

    Yuan, XiaoDong; Zhang, Jing; Quan, ChangBin; Tian, Yuan; Li, Hong; Ao, GuoKun

    2016-04-01

    To determine the feasibility and accuracy of a protocol for calculating whole-organ renal perfusion (renal blood flow [RBF]) and regional perfusion on the basis of biphasic computed tomography (CT), with concurrent dynamic contrast material-enhanced (DCE) CT perfusion serving as the reference standard. This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Biphasic CT of the kidneys, including precontrast and arterial phase imaging, was integrated with a first-pass dynamic volume CT protocol and performed and analyzed in 23 patients suspected of having renal artery stenosis. The perfusion value derived from biphasic CT was calculated as CT number enhancement divided by the area under the arterial input function and compared with the DCE CT perfusion data by using the paired t test, correlation analysis, and Bland-Altman plots. Correlation analysis was made between the RBF and the extent of renal artery stenosis. All postprocessing was independently performed by two observers and then averaged as the final result. Mean ± standard deviation biphasic and DCE CT perfusion data for RBF were 425.62 mL/min ± 124.74 and 419.81 mL/min ± 121.13, respectively (P = .53), and for regional perfusion they were 271.15 mL/min per 100 mL ± 82.21 and 266.33 mL/min per 100 mL ± 74.40, respectively (P = .31). Good correlation and agreement were shown between biphasic and DCE CT perfusion for RBF (r = 0.93; ±10% variation from mean perfusion data [P < .001]) and for regional perfusion (r = 0.90; ±13% variation from mean perfusion data [P < .001]). The extent of renal artery stenosis was negatively correlated with RBF with biphasic CT perfusion (r = -0.81, P = .012). Biphasic CT perfusion is clinically feasible and provides perfusion data comparable to DCE CT perfusion data at both global and regional levels in the kidney. Online supplemental material is available for this article.

  19. Triphasic contrast injection improves evaluation of dual energy lung perfusion in pulmonary CT angiography

    International Nuclear Information System (INIS)

    Kerl, J. Matthias; Bauer, Ralf W.; Renker, Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Schell, Boris; Larson, Maya Christina; Kromen, Wolfgang; Jacobi, Volkmar

    2011-01-01

    Purpose: Lung perfusion analysis at dual energy CT (DECT) is sensitive to beam hardening artifacts from dense contrast material (CM). We compared two scan and four CM injection protocols in terms of severity of artifacts and attenuation levels in the thoracic vessels. Methods and materials: Data of 120 patients who had undergone dual source dual energy CT pulmonary angiography for suspected acute pulmonary embolism were evaluated. Group 1 (n = 30) was scanned in craniocaudal direction using 64 × 0.6 mm collimation; groups 2–4 (n = 30 each) were scanned in caudocranial direction using 14 × 1.2 mm collimation. In groups 1–3 biphasic injection protocols with different amounts of CM and NaCl were investigated. In group 4 a split-bolus protocol with an initial CM bolus of 50 ml followed by 30 ml of a 70%:30% NaCl/CM mixture and a 50 ml NaCl chaser bolus was used. CT density values in the subclavian vein (SV), superior vena cava (SVC), pulmonary artery tree (PA), and the descending aorta (DA) were measured. Artifacts arising from the SV and SVC on DE pulmonary iodine distribution map were rated on a scale from 1 to 5 (1 = fully diagnostic; 5 = non-diagnostic) by two blinded readers. Results: In protocol 4 mean attenuation in the SV (645 ± 158 HU) and SVC (389 ± 114 HU) were significantly lower compared to groups 1–3 (p < 0.002). Artifacts in group 4 (1.1 ± 0.4 and 1.5 ± 0.7 for the SV and SVC, respectively) were rated significantly less severe compared to group 1 (3.2 ± 1.0 and 3.0 ± 1.1), 2 (2.6 ± 1.1 and 2.3 ± 1.0) and 3 (1.9 ± 0.9 and 1.9 ± 0.7) (p < 0.01 for all), whereas no significant difference was found between groups 1 and 2 for the subclavian vein (p = 0.07). Attenuation in the PA was also significantly lower in group 4 (282 ± 116 HU) compared to group 1 (397 ± 137 HU), group 2 (376 ± 115 HU) and group 3 (311 ± 104 HU), but still on a diagnostic level. Conclusion: Split-bolus injection provides sufficient attenuation for pulmonary DECT

  20. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    %, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography....... MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...

  1. CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    International Nuclear Information System (INIS)

    Talakic, Emina; Schoellnast, Helmut; Schaffellner, Silvia; Kniepeiss, Daniela; Mueller, Helmut; Stauber, Rudolf; Quehenberger, Franz

    2017-01-01

    To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volume scanner as well as invasive measurement of HVPG. Different CT perfusion algorithms (maximum slope analysis and Patlak plot) were used to measure hepatic arterial flow (HAF), portal venous flow (PVF), hepatic perfusion index (HPI), splenic arterial flow (SAF), splenic blood volume (SBV) and splenic clearance (SCL). Hepatic and splenic perfusion parameters were correlated with HVPG, and sensitivity and specificity for detection of severe portal hypertension (≥12 mmHg) were calculated. The Spearman correlation coefficient was -0.53 (p < 0.05) between SAF and HVPG, and -0.68 (p < 0.01) between HVPG and SCL. Using a cut-off value of 125 ml/min/100 ml for SCL, sensitivity for detection of a HVPG of ≥12 mmHg was 94%, and specificity 100%. There was no significant correlation between hepatic perfusion parameters and HVPG. CT perfusion in patients with cirrhosis showed a strong correlation between SCL and HVPG and may be used for detection of severe portal hypertension. (orig.)

  2. CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    Energy Technology Data Exchange (ETDEWEB)

    Talakic, Emina; Schoellnast, Helmut [Medical University of Graz, Division of General Radiology, Department of Radiology, Graz (Austria); Schaffellner, Silvia; Kniepeiss, Daniela; Mueller, Helmut [Medical University of Graz, Department of Surgery, Division of Transplantation Surgery, Graz (Austria); Stauber, Rudolf [Medical University of Graz, Department of Internal Medicine, Division of Gastoenterology and Hepatology, Graz (Austria); Quehenberger, Franz [Medical University of Graz, Institute for Medical Informatics, Statistics and Documentation, Graz (Austria)

    2017-10-15

    To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volume scanner as well as invasive measurement of HVPG. Different CT perfusion algorithms (maximum slope analysis and Patlak plot) were used to measure hepatic arterial flow (HAF), portal venous flow (PVF), hepatic perfusion index (HPI), splenic arterial flow (SAF), splenic blood volume (SBV) and splenic clearance (SCL). Hepatic and splenic perfusion parameters were correlated with HVPG, and sensitivity and specificity for detection of severe portal hypertension (≥12 mmHg) were calculated. The Spearman correlation coefficient was -0.53 (p < 0.05) between SAF and HVPG, and -0.68 (p < 0.01) between HVPG and SCL. Using a cut-off value of 125 ml/min/100 ml for SCL, sensitivity for detection of a HVPG of ≥12 mmHg was 94%, and specificity 100%. There was no significant correlation between hepatic perfusion parameters and HVPG. CT perfusion in patients with cirrhosis showed a strong correlation between SCL and HVPG and may be used for detection of severe portal hypertension. (orig.)

  3. Functional Imaging: CT and MRI

    OpenAIRE

    van Beek, Edwin JR; Hoffman, Eric A

    2008-01-01

    Numerous imaging techniques permit evaluation of regional pulmonary function. Contrast-enhanced CT methods now allow assessment of vasculature and lung perfusion. Techniques using spirometric controlled MDCT allow for quantification of presence and distribution of parenchymal and airway pathology, Xenon gas can be employed to assess regional ventilation of the lungs and rapid bolus injections of iodinated contrast agent can provide quantitative measure of regional parenchymal perfusion. Advan...

  4. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Nishimura, Tsunehiko; Kumita, Shin-ichirou; Hayashida, Kohei; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Ohno, Akira

    1991-01-01

    Fifteen cases with primary pulmonary hypertension (PPH) were classified into two groups by using the perfusion lung scan pattern. Eight cases had multiple, small, ill-defined defects (mottled pattern), and remaining seven cases had no mottled pattern. These two groups were compared with mean pulmonary arterial pressure (mean PAP), right ventricular ejection fraction (RVEF), blood gas at room air (PaO 2 ), and alveolar-arterial O 2 difference (A-aDo 2 ). The cases with mottled pattern showed a significant increase in mean PAP. There were no significant differences in RVEF, PaO 2 , and A-aDo 2 , between the groups. The survival rate of the patients with mottled pattern was significantly lower than that without mottled pattern (p<0.05). We concluded that perfusion lung scan is very useful for evaluation of the prognosis in primary pulmonary hypertension. (author)

  5. Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis - initial results

    International Nuclear Information System (INIS)

    Eichinger, Monika; Puderbach, Michael; Zuna, Ivan; Kauczor, Hans-Ulrich; Fink, Christian; Gahr, Julie; Mueller, Frank-Michael; Ley, Sebastian; Plathow, Christian; Tuengerthal, Siegfried

    2006-01-01

    This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/α/ST: 600 ms/28 ms/180 /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/α: 0.8/1.9 ms/40 ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients. (orig.)

  6. Assessment of pancreatic adenocarcinoma: use of low-dose whole pancreatic CT perfusion and individualized dual-energy CT scanning

    International Nuclear Information System (INIS)

    Li, Hai-ou; Guo, Jun; Li, Xiao; Qi, Yao-dong; Wang, Xi-ming; Xu, Zhuo-dong; Liu, Cheng; Chen, Jiu-hong

    2015-01-01

    The objective of this study was to investigate the value of low-dose whole pancreatic computed tomography (CT) perfusion integrated with individualized dual-energy CT (DECT) scanning in the diagnosis of pancreatic adenocarcinoma. Twenty patients with pancreatic adenocarcinoma underwent pancreatic CT perfusion as well as individualized dual-phase DECT pancreatic scans. Perfusion characteristics of non-tumourous pancreatic parenchyma and pancreatic adenocarcinoma were analysed. Weighted-average 120 kVp images and the optimal monoenergetic images in dual phase were reconstructed and the contrast noise ratio (CNR) of pancreas-to-tumour were compared. There were significant difference on blood flow as well as blood volume between pancreatic adenocarcinoma and the non-tumourous pancreatic parenchyma (P < 0.05), whereas no difference on permeability (P > 0.05). CNRs of pancreas-to-tumour in individualized pancreatic phase were significantly higher than those in venous phase (P < 0.05), and CNRs of optimal monoenergetic images were higher than those on weighted-average 120 kVp images (P < 0.05) in both phase. Total effective radiation dose of CT examination was around 9.32–13.75 mSv. Low-dose whole pancreatic CT perfusion can provide functional information, and the individualized pancreatic phase DECT scan is the optimal method for detecting pancreatic adenocarcinomas. The integration of the two techniques has great value in clinical application.

  7. Graft downsizing during ex vivo lung perfusion: case report and technical notes.

    Science.gov (United States)

    Nosotti, M; Rosso, L; Mendogni, P; Tosi, D; Palleschi, A; Righi, I; Froio, S; Valenza, F; Santambrogio, L

    2014-09-01

    Among patients with respiratory insufficiency awaiting lung transplantation, small adult patients have a lower opportunity of receiving size-matched pulmonary grafts, because of the shortage of donors, particularly those of small size. Reducing the size of an oversized graft is one of the methods to increase the donor pool; similarly, ex vivo lung perfusion is an emerging technique aimed toward the same purpose. We describe how we combined the 2 techniques (lobar transplantation plus contralateral nonanatomic graft reduction during ex vivo lung perfusion) to overcome graft shortage in a clinical case. For the 1st time, this case report demonstrates that surgical manipulation during ex vivo lung perfusion does not affect the functional improvement in a lung previously judged to be not suitable for transplantation. The 6-month follow-up results are similar to those of standard bilateral lung transplantation. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. The uptake and metabolism of cystamine and taurine by isolated, ventilated and perfused rat and rabbit lungs

    International Nuclear Information System (INIS)

    Sharma, R.; Kodavanti, U.P.; Smith, L.L.; Mehendale, H.M.

    1991-01-01

    Cystamine has been reported to be taken up by the lung slices and metabolized to taurine via hypotaurine through enzymatic processes. The objective of these studies was to determine whether intact isolated, ventilated and perfused rat and rabbit lungs also posses similar characteristics. The lungs were isolated from male New Zealand white rabbits and S-D rats and perfused with 20 μM [ 14 C] cystamine (Sp. Act., 16.4 mCi/mmol) for 60 min and 30 min, respectively. Cystamine and its metabolites in lung as well as in perfusate were separated by TLC and quantitated using scintillation spectrometry. Similar experiments were also conducted with 20 μM taurine to investigate its fate in perfused lungs. Significant pulmonary uptake of cystamine and taurine occurred during perfusion. Cystamine was metabolized to [ 14 C] hypotaurine and [ 14 C] taurine. No further metabolism of taurine was evident in rat or rabbit lungs. Inclusion of 1 nM GSH did not significantly alter the ability of lungs to sequester cystamine, but the metabolism of hypotaurine to taurine was decreased. It was evident that cystamine was metabolized to taurine by perfused lungs in the same way as in lung slices

  9. Perfusion study in the pulmonary hilar region by SPECT

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Kawase, Yoshiro

    1990-01-01

    Alveoli in the hilar region comprise the peripheral area containing daughter branches from subsegmental or one more divisional peripheral bronchi. Pulmonary perfusion in hilar region was examined by SPECT (single photon emission CT) in ten normal volunteers. ROI (region of interest) in the axial images were set in the hilar region, the upper, middle and lower lung fields with 10.8 mm thickness. Counts/one pixel (C/P) were calculated in these ROI. There was a tendency of C/P increase from upper to lower lung field. And there were no significant differences in C/P increase between hilar region and other axial fields. In the chronic obstructive pulmonary diseases, however, ventilation studies in the previous reports using Xe dynamic CT or PET (positron emission tomography) showed differences between outer region and hilar region. This method will be expected to evaluate the pulmonary perfusion not only in the whole lung but in different lung areas, including the hilar region in the chronic obstructive pulmonary diseases. (author)

  10. Lung perfusion scintigraphy in the diagnosis of peripheral pulmonary stenosis in patients after repair of Fallot tetralogy

    International Nuclear Information System (INIS)

    Sabiniewicz, R.; Chojnicki, M.; Alszewicz-Baranowska, J.; Erecinski, J.; Romanowicz, G.; Lass, P.; Bandurski, T.

    2002-01-01

    The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy in 43 (49%) of patients. In 27 of them heart catheterisation has been performed. Angiography revealed stenosis of the lung artery branch in 15/43 (34.9%) patients with abnormal perfusion lung scan and in 4/44 (9%) in patients with normal perfusion lung scan. Intervention procedures were carried out on 10 patients. Lung perfusion scintigraphy may prove a valuable, non-invasive screening tool in the assessment of patients after TOF repair, although both false-negative and false positive results may happen. Therefore, it should play an auxiliary role together with other diagnostic modalities. (author)

  11. Mass preserving image registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2012-01-01

    This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated...... on four groups of data: 44 pairs of longitudinal inspiratory chest CT scans with small difference in lung volume; 44 pairs of longitudinal inspiratory chest CT scans with large difference in lung volume; 16 pairs of expiratory and inspiratory CT scans; and 5 pairs of images extracted at end exhale and end...

  12. Measurement of lung volume by lung perfusion scanning using SPECT and prediction of postoperative respiratory function

    International Nuclear Information System (INIS)

    Andou, Akio; Shimizu, Nobuyosi; Maruyama, Shuichiro

    1992-01-01

    Measurement of lung volume by lung perfusion scanning using single photon emission computed tomography (SPECT) and its usefulness for the prediction of respiratory function after lung resection were investigated. The lung volumes calculated in 5 patients by SPECT (threshold level 20%) using 99m Tc-macroaggregated albumin (MAA), related very closely to the actually measured lung volumes. This results prompted us to calculate the total lung volume and the volume of the lobe to be resected in 18 patients with lung cancer by SPECT. Based on the data obtained, postoperative respiratory function was predicted. The predicted values of forced vital capacity (FVC), forced expiratory volume (FEV 1.0 ), and maximum vital volume (MVV) showed closer correlations with the actually measured postoperative values (FVC, FEV 1.0 , MVV : r=0.944, r=0.917, r=0.795 respectively), than the values predicted by the ordinary lung perfusion scanning. This method facilitates more detailed evaluation of local lung function on a lobe-by-lobe basis, and can be applied clinically to predict postoperative respiratory function. (author)

  13. CT hepatic perfusion measurement: Comparison of three analytic methods

    International Nuclear Information System (INIS)

    Kanda, Tomonori; Yoshikawa, Takeshi; Ohno, Yoshiharu; Kanata, Naoki; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2012-01-01

    Objectives: To compare the efficacy of three analytic methods, maximum slope (MS), dual-input single-compartment model (CM) and deconvolution (DC), for CT measurements of hepatic perfusion and assess the effects of extra-hepatic systemic factors. Materials and methods: Eighty-eight patients who were suspected of having metastatic liver tumors underwent hepatic CT perfusion. The scans were performed at the hepatic hilum 7–77 s after administration of contrast material. Hepatic arterial and portal perfusions (HAP and HPP, ml/min/100 ml) and arterial perfusion fraction (APF, %) were calculated with the three methods, followed by correlation assessment. Partial correlation analysis was used to assess the effects on hepatic perfusion values by various factors such as age, sex, risk of cardiovascular diseases, arrival time of contrast material at abdominal aorta, transit time from abdominal aorta to hepatic parenchyma, and liver dysfunction. Results: Mean HAP of MS was significantly higher than DC. HPP of CM was significantly higher than MS and CM, and HPP of MS was significantly higher than DC. There was no significant difference in APF. HAP and APF showed significant and moderate correlations among the methods. HPP showed significant and moderate correlations between CM and DC, and poor correlation between MS and CM or DC. All methods showed weak correlations between HAP or APF and age or sex. Finally, MS showed weak correlations between HAP or HPP and arrival time or cardiovascular risks. Conclusions: Hepatic perfusion values arrived at with the three methods are not interchangeable. CM and DC are less susceptible to extra-hepatic systemic factors

  14. Concentration of (+/-)-propranolol in isolated, perfused lungs of rat.

    Science.gov (United States)

    Dollery, C T; Junod, A F

    1976-01-01

    1 The metabolism and the accumulation of (+/-)-propranolol have been studied in isolated lungs of the rat, perfused with an artificial medium. 2 Little or no metabolism took place during the perfusion periods (up to 10 minutes). 3 Accumulation was observed with high tissue/medium ratios for substrate concentrations of 0.2 muM to 1 mM; there was evidence for saturability, but no real plateau could be seen. The presence of two binding sites with different affinities was established. 4 Cold greatly inhibited the accumulation process at low substrate concentrations, but had no effect at 1 mM propranolol. 5 Inhibition of accumulation was measured in the presence of imipramine, desmethylimipramine, nortryptiline, chlorpromazine and of Na+-free medium. Cocaine, 5-hydroxytryptamine and noradrenaline had no effect. Lidocaine enhanced the accumulation process. Release of previously bound propranolol was accelerated in the presence of propranolol and imipramine, unaffected by a Na+-free medium and decreased by cold and by lidocaine. 6 Experiments on lung tissue slices yielded qualitatively similar results to those obtained with perfused lungs. Ouabain and KCN had no or little effect on propranolol accumulation. PMID:1276542

  15. Multimodality functional imaging of spontaneous canine tumors using 64CU-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    DEFF Research Database (Denmark)

    Hansen, Anders E; Kristensen, Annemarie T; Law, Ian

    2012-01-01

    To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated.......To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated....

  16. Regional distribution of perfusion and ventilation in hamartoangiomyomatosis of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Tominaga, Shigeru; Ohsaka, Tomohisa; Nanbu, Masashi; Toyoda, Keiko; Mori, Yutaka; Kawakami, Kenji; Inatomi, Keiko; Kira, Shiro

    1989-01-01

    We investigated regional distribution of perfusion and ventilation in three cases of hamartoangiomyomatosis (HAM) by /sup 133/Xe gas and /sup 99m/Tc-MAA. In two cases, /sup 133/Xe washout were dominantly delayed in middle lung field and in the third case, it was delayed in upper lung field. This distribution was different from the result in the other chronic obstructive pulmonary disease (COPD). In most cases of COPD, /sup 133/Xe washout was prominently delayed in the lower lung field. Distribution of pulmonary perfusion in HAM were consistent with that of ventilation as in COPD.

  17. Evaluation of mosaic pattern areas in HRCT with Min-IP reconstructions in patients with pulmonary hypertension: Could this evaluation replace lung perfusion scintigraphy?

    International Nuclear Information System (INIS)

    Rossi, A.; Attinà, D.; Borgonovi, A.; Buia, F.; De Luca, F.; Guidalotti, P.L.; Fughelli, P.; Galiè, N.; Zompatori, M.

    2012-01-01

    Purpose: The aim of this study is to evaluate a possible correlation between areas of lung attenuation, found in minimum intensity projection (Min-IP) reconstruction images performed with high resolution computed tomography without contrast medium (HRCT), and areas of lung perfusion alteration, found in lung perfusion scintigraphy (LPS). Materials and methods: Two independent radiologists, unaware of LPS results, evaluated retrospectively a group of 113 patients affected by pulmonary hypertension (HP) of different aetiology. These have been examined in a period of two years in our centre both by spiral computed tomography (CT) with and without contrast-medium and by LPS. The final diagnosis was determined on clinical data, right heart catheterisation and contrast enhanced CT in angiographic phase (CTPA). We reconstructed the Min-IP images of lung parenchyma in all the cases both in HRCT without contrast-medium, and in contrast enhanced CT in angiographic phase (CTPA) in axial, sagittal and coronal planes. The obtained images were qualitatively graded into three categories of pulmonary attenuation: homogeneous, inhomogeneous with non-segmental patchy defects, inhomogeneous with segmental defects. The same criteria of classification were used also for LPS images. In the group of patients with chronic thromboembolic pulmonary hypertension (CTEPH) we also compared the number of areas of lung attenuation found in Min-IP images in HRCT without contrast-medium, and their exact localization, with not perfused areas in LPS. Gold standard for the diagnosis of pulmonary embolism was spiral contrast enhanced CT in angiographic phase (CTPA). Results: In all cases we found exact correspondence between the Min-IP images in HRCT with and without contras agent. The attenuation pattern seen on Min-IP images was concordant with those of LPS in 96 out of 113 patients (85%). In the remaining 17 cases (15%) it was discordant: in 12 cases inhomogeneous in Min-IP images (7 with non

  18. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    Energy Technology Data Exchange (ETDEWEB)

    Bisdas, Sotirios [JWG University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nemitz, Ole; Becker, Hartmut; Donnerstag, Frank [Hannover Medical School, Department of Neuroradiology, Hannover (Germany); Berding, Georg [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Weissenborn, Karin; Ahl, Bjoern [Hannover Medical School, Department of Neurology, Hannover (Germany)

    2006-10-15

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [{sup 15}O]H{sub 2}O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  19. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    International Nuclear Information System (INIS)

    Bisdas, Sotirios; Nemitz, Ole; Becker, Hartmut; Donnerstag, Frank; Berding, Georg; Weissenborn, Karin; Ahl, Bjoern

    2006-01-01

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [ 15 O]H 2 O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  20. Beware Cold Agglutinins in Organ Donors! Ex Vivo Lung Perfusion From an Uncontrolled Donation After Circulatory-Determination-of-Death Donor With a Cold Agglutinin: A Case Report.

    Science.gov (United States)

    Venkataraman, A; Blackwell, J W; Funkhouser, W K; Birchard, K R; Beamer, S E; Simmons, W T; Randell, S H; Egan, T M

    2017-09-01

    We began to recover lungs from uncontrolled donation after circulatory determination of death to assess for transplant suitability by means of ex vivo lung perfusion (EVLP) and computerized tomographic (CT) scan. Our first case had a cold agglutinin with an interesting outcome. A 60-year-old man collapsed at home and was pronounced dead by Emergency Medical Services personnel. Next-of-kin consented to lung retrieval, and the decedent was ventilated and transported. Lungs were flushed with cold Perfadex, removed, and stored cold. The lungs did not flush well. Medical history revealed a recent hemolytic anemia and a known cold agglutinin. Warm nonventilated ischemia time was 51 minutes. O 2 -ventilated ischemia time was 141 minutes. Total cold ischemia time was 6.5 hours. At cannulation for EVLP, established clots were retrieved from both pulmonary arteries. At initiation of EVLP with Steen solution, tiny red aggregates were observed initially. With warming, the aggregates disappeared and the perfusate became red. After 1 hour, EVLP was stopped because of florid pulmonary edema. The lungs were cooled to 20°C; tiny red aggregates formed again in the perfusate. Ex vivo CT scan showed areas of pulmonary edema and a pyramidal right middle lobe opacity. Dissection showed multiple pulmonary emboli-the likely cause of death. However, histology showed agglutinated red blood cells in the microvasculature in pre- and post-EVLP biopsies, which may have contributed to inadequate parenchymal preservation. Organ donors with cold agglutinins may not be suitable owing to the impact of hypothermic preservation. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. CT myocardial perfusion imaging. Ready for prime time?

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P.; Celeng, Csilla [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Ashley River Tower, Heart and Vascular Center, Charleston, SC (United States)

    2018-03-15

    The detection of functional coronary artery stenosis with coronary CT angiography (CCTA) is suboptimal. Additional CT myocardial perfusion imaging (CT-MPI) may be helpful to identify patients with myocardial ischaemia in whom coronary revascularization therapy would be beneficial. CT-MPI adds incremental diagnostic and prognostic value over obstructive disease on CCTA. It allows for the quantitation of myocardial blood flow and calculation of coronary flow reserve and shows good correlation with {sup 15}O-H{sub 2}O positron emission tomography and invasive fractional flow reserve. In addition, patients prefer CCTA/CT-MPI over SPECT, MRI and invasive coronary angiography. CT-MPI is ready for clinical use for detecting myocardial ischaemia caused by obstructive disease. Nevertheless, the clinical utility of CT-MPI to identify ischaemia in patients with non-obstructive/microvascular disease still has to be established. (orig.)

  2. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  3. Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke : A Diagnostic Performance Study

    NARCIS (Netherlands)

    Smith, E. J.; Vonken, E. -J.; Meijer, F. J. A.; Dankbaar, J. W.; Horsch, A. D.; van Ginneken, B.; Velthuis, B.; van der Schaaf, I.; Prokop, M.

    2015-01-01

    BACKGROUND AND PURPOSE: Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the

  4. Renal versus splenic maximum slope based perfusion CT modelling in patients with portal-hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Michael A. [University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); Karolinska Institutet, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden); Brehmer, Katharina [Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden); Svensson, Anders; Aspelin, Peter; Brismar, Torkel B. [Karolinska Institutet, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden); Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden)

    2016-11-15

    To assess liver perfusion-CT (P-CT) parameters derived from peak-splenic (PSE) versus peak-renal enhancement (PRE) maximum slope-based modelling in different levels of portal-venous hypertension (PVH). Twenty-four patients (16 men; mean age 68 ± 10 years) who underwent dynamic P-CT for detection of hepatocellular carcinoma (HCC) were retrospectively divided into three groups: (1) without PVH (n = 8), (2) with PVH (n = 8), (3) with PVH and thrombosis (n = 8). Time to PSE and PRE and arterial liver perfusion (ALP), portal-venous liver perfusion (PLP) and hepatic perfusion-index (HPI) of the liver and HCC derived from PSE- versus PRE-based modelling were compared between the groups. Time to PSE was significantly longer in PVH groups 2 and 3 (P = 0.02), whereas PRE was similar in groups 1, 2 and 3 (P > 0.05). In group 1, liver and HCC perfusion parameters were similar for PSE- and PRE-based modelling (all P > 0.05), whereas significant differences were seen for PLP and HPI (liver only) in group 2 and ALP in group 3 (all P < 0.05). PSE is delayed in patients with PVH, resulting in a miscalculation of PSE-based P-CT parameters. Maximum slope-based P-CT might be improved by replacing PSE with PRE-modelling, whereas the difference between PSE and PRE might serve as a non-invasive biomarker of PVH. (orig.)

  5. Utilization of the organ care system as ex-vivo lung perfusion after cold storage transportation.

    Science.gov (United States)

    Mohite, P N; Maunz, O; Popov, A-F; Zych, B; Patil, N P; Simon, A R

    2015-11-01

    The Organ Care System (OCS) allows perfusion and ventilation of the donor lungs under physiological conditions. Ongoing trials to compare preservation with OCS Lung with standard cold storage do not include donor lungs with suboptimal gas exchange and donor lungs treated with OCS following cold storage transportation. We present a case of a 48-yr-old man who received such lungs after cold storage transportation treated with ex-vivo lung perfusion utilizing OCS. © The Author(s) 2015.

  6. Effects of smoking on lung uptake of 201Tl during exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua

    2004-01-01

    Objective: To investigate the influence of smoking on lung uptake of 201 Tl during myocardial perfusion imaging. Methods: Ninety-two healthy subjects, with normal 201 Tl myocardial perfusion imaging findings but no evidence of left ventricular hypertrophy and pulmonary disease, were divided into three groups, smoker, nonsmoker and quitted smoker groups. Exercise/delay 201 Tl myocardial perfusion imaging was performed on all subjects included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: Both the lung/heart ratios during exercise in smoker (0.40 ± 0.07, F=10.635, P 201 Tl lung/heart ratios in smokers are higher than in nonsmokers and this must be kept in mind when 201 Tl lung/heart ratios are used clinically, even in quitted smokers

  7. Relative preservation of peripheral lung function in smoking-related pulmonary emphysema: assessment with 99mTc-MAA perfusion and dynamic 133Xe SPET

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kume, Norihiko; Matsunaga, Naofumi; Ogasawara, Nobuhiko; Motoyama, Kazumi; Hara, Akiko; Matsumoto, Tsuneo

    2000-01-01

    In this study the cross-sectional functional differences between the central and peripheral lung in smokers with pulmonary emphysema were evaluated by lung perfusion and dynamic xenon-133 single-photon emission tomography (SPET). The subjects were 81 patients with a long-term smoking history and relatively advanced emphysema, 17 non-smoker patients with non-obstructive lung diseases and six healthy non-smokers. Regional lung functional difference between the peripheral and central lung was assessed in the upper, middle and lower lung zones by technetium-99m macroaggregated albumin SPET and dynamic 133 Xe SPET. The distribution of emphysematous changes was assessed by density-mask computed tomography (CT) images which depicted abnormally low attenuation areas (LAAs) of less than -960 Hounsfield units. Two hundred and eighty-eight (59.2%) lung zones of 63 (77.7%) patients with pulmonary emphysema showed relative preservation of lung function in the peripheral lung, with a curvilinear band of normal perfusion (a stripe sign) and a significantly faster 133 Xe half-clearance time (T 1/2 ) than in central lung (P 1/2 in the peripheral lung area (P 1/2 values and LAA distributions between the central and peripheral lung. Relative preservation of peripheral lung function seems to be a characteristic feature in smoking-related pulmonary emphysema, and may indicate a lower susceptibility of peripheral parenchyma to the development of this disease. (orig.)

  8. Lung cancer mimicking lung abscess formation on CT images

    OpenAIRE

    Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi

    2014-01-01

    Patient: Male, 64 Final Diagnosis: Lung pleomorphic carcinoma Symptoms: Cough • fever Medication: — Clinical Procedure: — Specialty: Oncology Objective: Unusual clinical course Background: The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resemble...

  9. 18FDG uptake associated with CT density on PET/CT in lungs with and without chronic interstitial lung diseases

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Okada, Ken; Taki, Yasuyuki; Goto, Ryoi; Kinomura, Shigeo; Fukuda, Hiroshi

    2009-01-01

    The dependent-density of computed tomography (CT) images of positron emission tomography (PET)/CT is sometimes difficult to distinguish from chronic interstitial lung disease (ILD) when it accompanies increased 18 F-fluorodeoxy-D-glucose ( 18 FDG) uptake. Though the possible utility of 18 FDG-PET for the diagnosis of active ILD has been reported, the clinical relevance of mild lung 18 FDG uptake in ILD cases without signs and symptoms suggesting acute progression has not been described. This study aimed to test relationships between 18 FDG uptake and lung density on CT using PET/CT in patients with normal lung as well as clinically stable chronic ILD. Thirty-six patients with normal lungs (controls) and 28 patients with chronic ILD (ILD cases) without acute exacerbation were retrospectively selected from 18 FDG PET/CT scans performed in examination of malignant neoplasms. Elliptical regions of interest (ROIs) were placed on the lung. The relationships between CT density and 18 FDG uptake between the control and ILD cases were tested. The CT density and 18 FDG uptake had a linear correlation in both the controls and the ILD cases without a difference in their regression slopes, and they were overlapped between the controls and the ILD cases with higher mean values in the ILD cases. Lung 18 FDG uptake was considered to reflect a gravity-dependent tissue density in the normal lung. Though the lung 18 FDG uptake as well as the CT density tended to be higher in chronic ILD patients, it may be difficult to distinguish them in normal dependent regions from those related to chronic ILD in some cases. (author)

  10. Lung ventilation-perfusion imbalance in pulmonary emphysema. Assessment with automated V/Q quotient SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Koike, Hiroaki; Iwanaga, Hideyuki; Tokuda, Osamu; Okada, Munemasa; Matsunaga, Naofumi

    2010-01-01

    Tc-99m-Technegas-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P<0.0001 and P<0.001, respectively), and a significant correlation was found between SD and A-aDO2 (P<0.0001). V/Q quotient SPECT appears to be more sensitive to detect emphysematous lungs compared with morphologic CT in patients with emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema. (author)

  11. To Find a Better Dosimetric Parameter in the Predicting of Radiation-Induced Lung Toxicity Individually: Ventilation, Perfusion or CT based.

    Science.gov (United States)

    Xiao, Lin-Lin; Yang, Guoren; Chen, Jinhu; Wang, Xiaohui; Wu, Qingwei; Huo, Zongwei; Yu, Qingxi; Yu, Jinming; Yuan, Shuanghu

    2017-03-15

    This study aimed to find a better dosimetric parameter in predicting of radiation-induced lung toxicity (RILT) in patients with non-small cell lung cancer (NSCLC) individually: ventilation(V), perfusion (Q) or computerized tomography (CT) based. V/Q single-photon emission computerized tomography (SPECT) was performed within 1 week prior to radiotherapy (RT). All V/Q imaging data was integrated into RT planning system, generating functional parameters based on V/Q SPECT. Fifty-seven NSCLC patients were enrolled in this prospective study. Fifteen (26.3%) patients underwent grade ≥2 RILT, the remaining forty-two (73.7%) patients didn't. Q-MLD, Q-V20, V-MLD, V-V20 of functional parameters correlated more significantly with the occurrence of RILT compared to V20, MLD of anatomical parameters (r = 0.630; r = 0.644; r = 0.617; r = 0.651 vs. r = 0.424; r = 0.520 p < 0.05, respectively). In patients with chronic obstructive pulmonary diseases (COPD), V functional parameters reflected significant advantage in predicting RILT; while in patients without COPD, Q functional parameters reflected significant advantage. Analogous results were existed in fractimal analysis of global pulmonary function test (PFT). In patients with central-type NSCLC, V parameters were better than Q parameters; while in patients with peripheral-type NSCLC, the results were inverse. Therefore, this study demonstrated that choosing a suitable dosimetric parameter individually can help us predict RILT accurately.

  12. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].

    Science.gov (United States)

    Parra-Bravo, José Rafael; Apolonio-Martínez, Adriana; Estrada-Loza, María de Jesús; Beirana-Palencia, Luisa Gracia; Ramírez-Portillo, César Iván

    2015-01-01

    The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusionductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  13. Reevaluation of lung perfusion scintigrams with 99mTc-macroaggregated albumin (Tc-MAA) as a tool of diagnostic procedures of chronic pulmonary emphysema

    International Nuclear Information System (INIS)

    Kitahara, Yoshinari; Maruyama, Masao; Takamoto, Masahiro; Tanaka, Yasushi; Harada, Susumu; Harada, Yasuko; Ishibashi, Tsuneo; Shinoda, Atsushi

    1991-01-01

    We performed scintiscanning with Tc-MAA lung perfusion in thirty cases of chronic pulmonary emphysema (CPE) and thirty cases of bronchial asthma. In the former group, all of the cases showed the definite emphysematous changes on computed tomography (CT). It seemed that the whole impression to scintigram could diagnose CPE almost correctly. As the most important abnormality in scintigrams of CPE was their filling defects, we examined the characteristics of the defect-lesions. The results were as follows: firstly, the main lesions extended to the lobar to half-lobar size; secondly, defects were multiple in general; and thirdly, the distribution of defects was diffuse. Whereas the lesion in the scintigram is nonspecific for diagnosis of CPE in contrast to CT, we conclude that perfusion scintigram is valuable to evaluate the severity of CPE. (author)

  14. Mosaic Pattern of Lung Attenuation on Chest CT in Patients with Pulmonary Hypertension

    Directory of Open Access Journals (Sweden)

    Kamonpun Ussavarungsi

    2015-09-01

    Full Text Available A mosaic pattern of lung attenuation on chest computed tomography (CT may be due to various etiologies. There is limited published data on CT results when used to evaluate pulmonary hypertension (PH. We retrospectively studied the frequency of mosaic pattern in patients with PH and the cause of the PH by diagnostic group, as well as the correlation between the mosaic pattern and the following: demographics, severity of the PH, main pulmonary artery (PA size, PA/aorta (PA/Ao ratio, pulmonary function tests (PFT, and ventilation perfusion scan results. Overall, 18% of the cohort had CT mosaic pattern (34/189. Mosaic pattern was present in 17/113 (15% in Group 1 pulmonary arterial hypertension, 5/13 (28% in Group 2 pulmonary venous hypertension and 8/50 (16% in Group 3 PH. Conversely, Group 4 chronic thromboembolic PH was more prevalent in 4/8 (50%. Main PA size, PA/Ao ratio, and segmental perfusion defect were positively associated with mosaic pattern. In contrast, factors such as age, gender, body mass index, functional class, hemodynamic data, and PFT values were not associated with mosaic pattern. Mosaic pattern is not specific as an isolated finding for distinguishing the subtype of PH.

  15. Diagnostic and clinical benefit of combined coronary calcium and perfusion assessment in patients undergoing PET/CT myocardial perfusion stress imaging.

    Science.gov (United States)

    Bybee, Kevin A; Lee, John; Markiewicz, Richard; Longmore, Ryan; McGhie, A Iain; O'Keefe, James H; Hsu, Bai-Ling; Kennedy, Kevin; Thompson, Randall C; Bateman, Timothy M

    2010-04-01

    A limitation of stress myocardial perfusion imaging (MPI) is the inability to detect non-obstructive coronary artery disease (CAD). One advantage of MPI with a hybrid CT device is the ability to obtain same-setting measurement of the coronary artery calcium score (CACS). Utilizing our single-center nuclear database, we identified 760 consecutive patients with: (1) no CAD history; (2) a normal clinically indicated Rb-82 PET/CT stress perfusion study; and (3) a same-setting CAC scan. 487 of 760 patients (64.1%) had subclinical CAD based on an abnormal CACS. Of those with CAC, the CACS was > or =100, > or =400, and > or =1000 in 47.0%, 22.4%, and 8.4% of patients, respectively. Less than half of the patients with CAC were receiving aspirin or statin medications prior to PET/CT imaging. Patients with CAC were more likely to be initiated or optimized on proven medical therapy for CAD immediately following PET/CT MPI compared to those without CAC. Subclinical CAD is common in patients without known CAD and normal myocardial perfusion assessed by hybrid PET/CT imaging. Identification of CAC influences subsequent physician prescribing patterns such that those with CAC are more likely to be treated with proven medical therapy for the treatment of CAD.

  16. Lung perfusion scintigraphy in congenital heart disease

    International Nuclear Information System (INIS)

    Sugimura, Hiroshi; Nagamachi, Shigeki; Hoshi, Hiroaki; Jinnouchi, Seishi; Oonishi, Takashi; Futami, Shigemi; Watanabe, Katsushi

    1990-01-01

    Lung perfusion scintigrams were reviewed retrospectively in 28 patients with congenital heart disease, whose ages ranged from the first year to 16 years with an average age of 5 years and 6 months. Seventy four MBq (2 mCi), 111 MBq (2 mCi), and 185 MBq (5 mCi) of Tc-99m macroaggregated albumin were iv injected in the age groups of 0-3, 4-11, and more than 11 years, respectively. Five minutes later, images were obtained in six projections. Abnormal findings on lung perfusion scintigrams were observed in 13 patients (46%). Of these patients, 8 (29%) had a partially decreased blood flow and 5 (17%) had a decreased blood flow in the unilateral lung. No significant difference in the occurrence of abnormal findings was observed among the age groups, although they tended to occur in younger patients. Sex, underlying conditions, and hemodynamics were also independent of scintigraphically abnormal findings. Even when classifying the patients as having either cyanotic or non-cyanotic heart disease, no significant difference in hemodynamics was observed between the group of abnormal findings and the group of normal findings. Pulmonary arteriography available in all patients failed to reveal abnormal findings, with the exception of pulmonary artery stenosis in 2 patients that corresponded to a decreased blood flow in the unilateral lung. Pulmonary artery stenosis seemed to be responsible for abnormal pulmonary blood flow, although other causes remained uncertain. (N.K.)

  17. Isoattenuating insulinomas at biphasic contrast-enhanced CT: frequency, clinicopathologic features and perfusion characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Sun, Hao; Wang, Xuan; He, Yong-lan; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2016-10-15

    We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 2014, 170 patients (66 male, 104 female) with endogenous hyperinsulinemic hypoglycemia underwent biphasic contrast-enhanced CT before surgery, and 129 of those patients also received preoperative whole-pancreas CT perfusion. A total of 181 tumours were proved histopathologically after surgery. Enhancement pattern and regional pancreatic perfusion characteristics were analyzed. Clinical features, tumour size and pathological grading were investigated. The frequency of isoattenuating tumours was 24.9 %. Tumour size and WHO grading was not significantly different between isoattenuating and hyperattenuating tumours. Tumour-free regions had identical blood flow (BF) regardless of their location (p = 0.35). Isoattenuating tumour-harbouring regions had lower BF compared with hyperattenuating tumour-harbouring regions; both showed higher BF compared with tumour-free neighbourhood regions (all p < 0.01). For patients with isoattenuating tumours, the overall hospital stay was longer (p < 0.01). A substantial subset of insulinomas were isoattenuating on biphasic CT. CT perfusion showed higher BF in tumour-harbouring regions compared to tumour-free regions, providing a clue for tumour regionalization. (orig.)

  18. Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Coenen, Adriaan; Lubbers, Marisa M.; Dedic, Admir; Chelu, Raluca G.; Geuns, Robert-Jan M. van; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands); Kurata, Akira; Kono, Atsushi; Dijkshoorn, Marcel L. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Rossi, Alexia [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Barts Health NHS Trust, NIHR Cardiovascular Biomedical Research Unit at Barts, William Harvey Research Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London and Department of Cardiology, London (United Kingdom)

    2017-06-15

    To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. (orig.)

  19. CT of malignant choroidal melanoma - morphology and perfusion characteristics

    International Nuclear Information System (INIS)

    Heller, M.; Hagemann, J.; Jend, H.H.; Guthoff, R.

    1982-01-01

    The computed tomographic morphology of malignant choroidal melanoma and its perfusion characteristics are described. Thirty-three static and serial CT examinations made on 29 patients with choroidal melanoma, three with pseudotumors of the macula and one with choroidal metastasis revealed the choroidal melanoma to be usually a hyperdense, markedly perfused tumor, while the non-contrast, diagnostically undifferentiable pseudotumors and the choroidal metastasis, revealed no significant change in density after the administration of contrast material. Density values or perfusion characteristics of choroidal melanoma that are outside of the normal range are a result of secondary changes within the immediate surroundings of the tumor, such as detachment of the retina, tumor-induced glaucoma, or tumor necrosis. (orig.)

  20. Emergency perfusion lung scan of pulmonary embolism

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Kabuto, Hiroko; Rikimaru, Shigeho

    1984-01-01

    Pulmonary embolism (PE) has been reported to be quite rare in Japan, and there have been few clinical studies on the nuclear diagnosis of PE with the exception of several case reports. However, we have experienced 12 acute PE, and 2 chronic PE in 5 years 2 months. In 33 emergency cases who were highly suspected to have PE, we could diagnose 12 cases of PE, and 19 cases of non-PE. However, the remaining 2 cases were equivocal because of underlying chronic lung disease. Using Kr-81m ventilation lung scan, V/Q mismatch was found in all of 10 cases. Usefulness of emergency perfusion lung scan in Japan should be stressed. (author)

  1. A potential to reduce pulmonary toxicity: The use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Christian, Judith A.; Partridge, Mike; Niotsikou, Elena; Cook, Gary; Parker, Michelle; Bedford, James L.; Brada, Michael

    2007-01-01

    Background and purpose: The study aimed to examine specific avoidance of functional lung (FL) defined by a single photon emission computerized tomography (SPECT) lung perfusion scan, using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3-DCRT) in patients with non-small cell lung cancer (NSCLC). Materials and methods: Patients with NSCLC underwent planning computerized tomography (CT) and lung perfusion SPECT scan in the treatment position using fiducial markers to allow co-registration in the treatment planning system. Radiotherapy (RT) volumes were delineated on the CT scan. FL was defined using co-registered SPECT images. Two inverse coplanar RT plans were generated for each patient: 4-field 3-DCRT and 5-field step-and-shoot IMRT. 3-DCRT plans were created using automated AutoPlan optimisation software, and IMRT plans were generated employing Pinnacle 3 treatment planning system (Philips Radiation Oncology Systems). All plans were prescribed to 64 Gy in 32 fractions using data for the 6 MV beam from an Elekta linear accelerator. The objectives for both plans were to minimize the volume of FL irradiated to 20 Gy (fV 20 ) and dose variation within the planning target volume (PTV). A spinal cord dose was constrained to 46 Gy. Volume of PTV receiving 90% of the prescribed dose (PTV 90 ), fV 20 , and functional mean lung dose (fMLD) were recorded. The PTV 90 /fV 20 ratio was used to account for variations in both measures, where a higher value represented a better plan. Results: Thirty-four RT plans of 17 patients with stage I-IIIB NSCLC suitable for radical RT were analysed. In 6 patients with stage I-II disease there was no improvement in PTV 90 , fV 20 , PTV/fV 20 ratio and fMLD using IMRT compared to 3-DCRT. In 11 patients with stage IIIA-B disease, the PTV was equally well covered with IMRT and 3-DCRT plans, with IMRT producing better PTV 90 /fV 20 ratio (mean ratio - 7.2 vs. 5.3, respectively, p = 0.001) and reduced f

  2. Role of dynamic CT perfusion study in evaluating various intracranial space-occupying lesions

    International Nuclear Information System (INIS)

    Kamble, Ravindra B; Jayakumar, Peruvumba N; Shivashankar, Ravishankar

    2015-01-01

    Differentiating intracranial mass lesions on CT scan is challenging. The purpose of our study was to determine the perfusion parameters in various intracranial space-occupying lesions (ICSOL), differentiate benign and malignant lesions, and differentiate between grades of gliomas. We performed CT perfusion (CTP) in 64 patients, with age ranging from 17 to 68 years, having space-occupying lesions in brain and calculated relative cerebral blood flow (rCBF) and relative cerebral blood volume (rCBV). We found significantly lower perfusion in low-grade gliomas as compared to high-grade tumors, lymphoma, and metastases. Similarly in infective lesions, TWT and abscesses showed significantly lower perfusion compared to TOT. In ring enhancing lesions, capsule of TWT showed significantly lower perfusion as compared to abscesses, TOT, and metastases. Thus, in conclusion, infective lesions can be differentiated from tumors like lymphomas, high-grade gliomas, or metastases based on perfusion parameters. The cut off value of rCBV 1.64 can be used to differentiate between low grade and high grade gliomas. However, depending only on perfusion parameters, differentiation between the tumors like lymphomas, high-grade gliomas, and metastases may not be possible

  3. Role of dynamic CT perfusion study in evaluating various intracranial space-occupying lesions

    Directory of Open Access Journals (Sweden)

    Ravindra B Kamble

    2015-01-01

    Full Text Available Aims: Differentiating intracranial mass lesions on CT scan is challenging. The purpose of our study was to determine the perfusion parameters in various intracranial space-occupying lesions (ICSOL, differentiate benign and malignant lesions, and differentiate between grades of gliomas. Materials and Methods: We performed CT perfusion (CTP in 64 patients, with age ranging from 17 to 68 years, having space-occupying lesions in brain and calculated relative cerebral blood flow (rCBF and relative cerebral blood volume (rCBV. Results: We found significantly lower perfusion in low-grade gliomas as compared to high-grade tumors, lymphoma, and metastases. Similarly in infective lesions, TWT and abscesses showed significantly lower perfusion compared to TOT. In ring enhancing lesions, capsule of TWT showed significantly lower perfusion as compared to abscesses, TOT, and metastases. Conclusion: Thus, in conclusion, infective lesions can be differentiated from tumors like lymphomas, high-grade gliomas, or metastases based on perfusion parameters. The cut off value of rCBV 1.64 can be used to differentiate between low grade and high grade gliomas. However, depending only on perfusion parameters, differentiation between the tumors like lymphomas, high-grade gliomas, and metastases may not be possible.

  4. Lung perfusion and ventilation scintigraphy in pre- and postoperative diagnostics

    International Nuclear Information System (INIS)

    Sandrock, D.; Munz, D.L.

    1998-01-01

    Lung perfusion (Tc-99m labeled albumin particles) and ventilation (Xe-133 gas) are used prior to thoracic surgery in order to evaluate changes in perfusion and ventilation due to the underlying diseases. Furthermore, perfusion scintigraphy allows combined with spirometry the prediction of the postinterventional vital capacity and the forced expiratory volume in 1 s. The correlation coefficient for this procedure compared with values measured postoperatively are in the range of 0.8. The method allows the assessment of operability in terms of postinterventional function. (orig.) [de

  5. Multimodality functional imaging of spontaneous canine tumors using 64Cu-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    International Nuclear Information System (INIS)

    Hansen, Anders E.; Kristensen, Annemarie T.; Law, Ian; McEvoy, Fintan J.; Kjær, Andreas; Engelholm, Svend A.

    2012-01-01

    Purpose: To compare the distribution and uptake of the hypoxia tracer 64 Cu-diacetyl-bis(N 4 -methylthiosemicarbazone) ( 64 Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition 64 Cu-ATSM distribution over time was evaluated. Methods and materials: Nine spontaneous cancer-bearing dogs were prospectively enrolled. FDG (1 h pi.) and 64 Cu-ATSM (3 and 24 h pi.) PET/CT were performed over three consecutive days. DCE-pCT was performed on day 2. Tumor uptake of FDG and 64 Cu-ATSM was assessed semi-quantitatively and the distribution of FDG, 64 Cu-ATSM and CT perfusion parameters correlated. Results: 64 Cu-ATSM distribution on scans performed 24 h apart displayed moderate to strong correlation; however, temporal changes were observed. The spatial distribution pattern of 64 Cu-ATSM between scans was moderately to strongly positively correlated to FDG, whereas the correlation of CT perfusion parameters to FDG and to 64 Cu-ATSM yielded more varying results. Conclusions: 64 Cu-ATSM uptake was positively correlated to FDG. 64 Cu-ATSM was found to be relatively stable between PET scans performed at different time points, important temporal changes were however observed in hypo-perfused regions. These findings potentially indicate that prolonged uptake periods for 64 Cu-ATSM imaging may be needed. Although a moderate to strong correlation between 64 Cu-ATSM and FDG PET/CT is observed, the two tracers provide different biological information with an overlapping spatial distribution.

  6. Radiation-Induced Reductions in Regional Lung Perfusion: 0.1-12 Year Data From a Prospective Clinical Study

    International Nuclear Information System (INIS)

    Zhang Junan; Ma Jinli; Zhou Sumin; Hubbs, Jessica L.; Wong, Terence Z.; Folz, Rodney J.; Evans, Elizabeth S.; Jaszczak, Ronald J.; Clough, Robert; Marks, Lawrence B.

    2010-01-01

    Purpose: To assess the time and regional dependence of radiation therapy (RT)-induced reductions in regional lung perfusion 0.1-12 years post-RT, as measured by single photon emission computed tomography (SPECT) lung perfusion. Materials/Methods: Between 1991 and 2005, 123 evaluable patients receiving RT for tumors in/around the thorax underwent SPECT lung perfusion scans before and serially post-RT (0.1-12 years). Registration of pre- and post-RT SPECT images with the treatment planning computed tomography, and hence the three-dimensional RT dose distribution, allowed changes in regional SPECT-defined perfusion to be related to regional RT dose. Post-RT follow-up scans were evaluated at multiple time points to determine the time course of RT-induced regional perfusion changes. Population dose response curves (DRC) for all patients at different time points, different regions, and subvolumes (e.g., whole lungs, cranial/caudal, ipsilateral/contralateral) were generated by combining data from multiple patients at similar follow-up times. Each DRC was fit to a linear model, and differences statistically analyzed. Results: In the overall groups, dose-dependent reductions in perfusion were seen at each time post-RT. The slope of the DRC increased over time up to 18 months post-RT, and plateaued thereafter. Regional differences in DRCs were only observed between the ipsilateral and contralateral lungs, and appeared due to tumor-associated changes in regional perfusion. Conclusions: Thoracic RT causes dose-dependent reductions in regional lung perfusion that progress up to ∼18 months post-RT and persists thereafter. Tumor shrinkage appears to confound the observed dose-response relations. There appears to be similar dose response for healthy parts of the lungs at different locations.

  7. Enhanced CT perfusion cut-off sign in midgut volvulus

    International Nuclear Information System (INIS)

    Henesch, Stephen M.; Jaramillo, Diego M.; Nance, Michael L.

    2006-01-01

    We present a case of malrotation with midgut volvulus in an infant in which we discovered a unique CT sign called the perfusion cut-off sign. We hope this case will help establish this crucial diagnosis in other cases. (orig.)

  8. Enhanced CT perfusion cut-off sign in midgut volvulus

    Energy Technology Data Exchange (ETDEWEB)

    Henesch, Stephen M.; Jaramillo, Diego M. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Nance, Michael L. [Children' s Hospital of Philadelphia, Department of Surgery, Philadelphia, PA (United States)

    2006-04-15

    We present a case of malrotation with midgut volvulus in an infant in which we discovered a unique CT sign called the perfusion cut-off sign. We hope this case will help establish this crucial diagnosis in other cases. (orig.)

  9. CT perfusion technique for assessment of early kidney allograft dysfunction: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Helck, A.; Notohamiprodjo, M.; Schoen, F.; Nikolaou, K.; Clevert, D.A.; Reiser, M.; Becker, C. [Ludwig-Maximilians-University of Munich, Department of Clinical Radiology, University Hospitals Grosshadern, Munich (Germany); Wessely, M.; Schoenermarck, U.; Fischereder, M. [Ludwig-Maximilians-University of Munich, Department of Internal Medicine IV, Nephrology, University Hospitals Grosshadern, Munich (Germany); Klotz, E. [Siemens Healthcare, Computed Tomography, Forchheim (Germany)

    2013-09-15

    To assess the benefit of quantitative computed tomography (CT) perfusion for differentiating acute tubular necrosis (ATN) and acute rejection (AR) in kidney allografts. Twenty-two patients with acute kidney allograft dysfunction caused by either AR (n = 6) or ATN (n = 16) were retrospectively included in the study. All patients initially underwent a multiphase CT angiography (CTA) protocol (12 phases, one phase every 3.5 s) covering the whole graft to exclude acute postoperative complications. Multiphase CT dataset and dedicated software were used to calculate renal blood flow. Renal biopsy or clinical course of disease served as the standard of reference. Mean effective radiation dose and mean amount of contrast media were calculated. Renal blood flow values were significantly lower (P = 0.001) in allografts undergoing AR (48.3 {+-} 21 ml/100 ml/min) compared with those with ATN (77.5 {+-} 21 ml/100 ml/min). No significant difference (P = 0.71) was observed regarding creatinine level with 5.65 {+-} 3.1 mg/dl in AR and 5.3 {+-} 1.9 mg/dl in ATN. The mean effective radiation dose of the CT perfusion protocol was 13.6 {+-} 5.2 mSv; the mean amount of contrast media applied was 34.5 {+-} 5.1 ml. All examinations were performed without complications. CT perfusion of kidney allografts may help to differentiate between ATN and rejection. (orig.)

  10. CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    Science.gov (United States)

    Talakić, Emina; Schaffellner, Silvia; Kniepeiss, Daniela; Mueller, Helmut; Stauber, Rudolf; Quehenberger, Franz; Schoellnast, Helmut

    2017-10-01

    To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volume scanner as well as invasive measurement of HVPG. Different CT perfusion algorithms (maximum slope analysis and Patlak plot) were used to measure hepatic arterial flow (HAF), portal venous flow (PVF), hepatic perfusion index (HPI), splenic arterial flow (SAF), splenic blood volume (SBV) and splenic clearance (SCL). Hepatic and splenic perfusion parameters were correlated with HVPG, and sensitivity and specificity for detection of severe portal hypertension (≥12 mmHg) were calculated. The Spearman correlation coefficient was -0.53 (p portal hypertension. • SAF and SCL are statistically significantly correlated with HVPG • SCL showed stronger correlation with HVPG than SAF • 125 ml/min/100 ml SCL-cut-off yielded 94 % sensitivity, 100 % specificity for severe PH • HAF, PVF and HPI showed no statistically significant correlation with HVPG.

  11. Multiphasic perfusion CT in acute middle cerebral artery ischemic stroke: prediction of final infarct volume and correlation with clinical outcome

    International Nuclear Information System (INIS)

    Yi, Chin A; Na, Dong Gyu; Ryoo, Jae Wook; Moon, Chan Hong; Byun, Hong Sik; Roh, Hong Gee; Moon, Won Jin; Lee, Kwang Ho; Lee, Soo Joo

    2002-01-01

    To assess the utility of multiphasic perfusion CT in the prediction of final infarct volume, and the relationship between lesion volume revealed by CT imaging and clinical outcome in acute ischemic stroke patients who have not undergone thrombolytic therapy. Thirty-five patients underwent multiphasic perfusion CT within six hours of stroke onset. After baseline unenhanced helical CT scanning, contrast-enhanced CT scans were obtained 20, 34, 48, and 62 secs after the injection of 90 mL contrast medium at a rate of 3 mL/sec. CT peak and total perfusion maps were obtained from serial CT images, and the initial lesion volumes revealed by CT were compared with final infarct volumes and clinical scores. Overall, the lesion volumes seen on CT peak perfusion maps correlated most strongly with final infarct volumes (R2=0.819, p<0.001, slope of regression line=1.016), but individual data showed that they were less than final infarct volume in 31.4% of patients. In those who showed early clinical improvement (n=6), final infarct volume tended to be overestimated by CT peak perfusion mapping and only on total perfusion maps was there significant correlation between lesion volume and final infarct volume (R2=0.854, p=0.008). The lesion volumes depicted by CT maps showed moderate correlation with baseline clinical scores and clinical outcomes (R=0.445-0.706, p≤0.007). CT peak perfusion maps demonstrate strong correlation between lesion volume and final infarct volume, and accurately predict final infarct volume in about two-thirds of the 35 patients. The lesion volume seen on CT maps shows moderate correlation with clinical outcome

  12. Ventilation-perfusion-lungscintigraphy using PET and {sup 68}Ga-labeled radiopharmaceuticals; Ventilations-Perfusions-Lungenszintigraphie mit der PET und {sup 68}Ga-markierten Radiopharmaka

    Energy Technology Data Exchange (ETDEWEB)

    Kotzerke, J. [Technische Univ. Dresden (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Technische Univ. Dresden (Germany). OncoRay - Zentrum fuer Innovationskompetenz Strahlenforschung in der Onkologie; Forschungszentrum Dresden-Rossendorf e.V. (FZR) (Germany). PET-Zentrum; Andreeff, M.; Wunderlich, G.; Zoephel, K. [Technische Univ. Dresden (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Wiggermann, P. [Technische Univ. Dresden (Germany). Inst. und Poliklinik fuer Diagnostische Radiologie

    2010-07-01

    Aim: Imaging of lung perfusion with positron emission tomography (PET) is already possible with {sup 68}Ga labeled denaturized albumin. The purpose of our study was to produce and test a {sup 68}Ga labeled aerosol (Galligas {sup registered}) for ventilation and {sup 68}Ga labeled albumin particles (microspheres) for perfusion imaging with PET. Patients, methods: Galligas was produced by simmering and burning generator eluted {sup 68}Ga solution (100 MBq/0.1ml) in an ordinary technegas generator. Fifteen patients with suspicion on pulmonary embolism underwent PET/CT (Biograph 16) after inhalation of Galligas and application of {sup 68}Ga labeled microspheres. A low dose CT was acquired for attenuation correction (AC). Images were reconstructed with and without AC. The inhaled activity was calculated compared to the activity injected. Results: Inhaled radioaerosol Galligas demonstrated typical distribution as known from {sup 99m}Tc-labeled technegas with homogeneous distribution in lung without hilar deposits. Attenuation corrected images resulted in artefacts in the lung base. Therefore, non-corrected images were used for making the results. Three out of fifteen patients showed a deficient perfusion whereas ventilation was normal corresponding to pulmonary embolism. Conclusion: Lung scintigraphy with PET is feasible. Galligas is simple to produce (analogously to technegas). {sup 68}Ga labeled microspheres are available. The method is applicable to daily routine and rendered clinically relevant informations. (orig.)

  13. Volume perfusion CT imaging of cerebral vasospasm: diagnostic performance of different perfusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Ahmed E. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Radiology, Tuebingen (Germany); Afat, Saif; Nikoubashman, Omid; Mueller, Marguerite; Wiesmann, Martin; Brockmann, Carolin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Schubert, Gerrit Alexander [RWTH Aachen University, Department of Neurosurgery, Aachen (Germany); Bier, Georg [Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Brockmann, Marc A. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); University Hospital Mainz, Department of Neuroradiology, Mainz (Germany)

    2016-08-15

    In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting <50 %, 2 - vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting < 50 %, 2 - vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm. (orig.)

  14. Interval lung cancer after a negative CT screening examination: CT findings and outcomes in National Lung Screening Trial participants

    International Nuclear Information System (INIS)

    Gierada, David S.; Pinsky, Paul F.; Duan, Fenghai; Garg, Kavita; Hart, Eric M.; Kazerooni, Ella A.; Nath, Hrudaya; Watts, Jubal R.; Aberle, Denise R.

    2017-01-01

    This study retrospectively analyses the screening CT examinations and outcomes of the National Lung Screening Trial (NLST) participants who had interval lung cancer diagnosed within 1 year after a negative CT screen and before the next annual screen. The screening CTs of all 44 participants diagnosed with interval lung cancer (cases) were matched with negative CT screens of participants who did not develop lung cancer (controls). A majority consensus process was used to classify each CT screen as positive or negative according to the NLST criteria and to estimate the likelihood that any abnormalities detected retrospectively were due to lung cancer. By retrospective review, 40/44 cases (91%) and 17/44 controls (39%) met the NLST criteria for a positive screen (P < 0.001). Cases had higher estimated likelihood of lung cancer (P < 0.001). Abnormalities included pulmonary nodules ≥4 mm (n = 16), mediastinal (n = 8) and hilar (n = 6) masses, and bronchial lesions (n = 6). Cancers were stage III or IV at diagnosis in 32/44 cases (73%); 37/44 patients (84%) died of lung cancer, compared to 225/649 (35%) for all screen-detected cancers (P < 0.0001). Most cases met the NLST criteria for a positive screen. Awareness of missed abnormalities and interpretation errors may aid lung cancer identification in CT screening. (orig.)

  15. Interval lung cancer after a negative CT screening examination: CT findings and outcomes in National Lung Screening Trial participants

    Energy Technology Data Exchange (ETDEWEB)

    Gierada, David S. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, Box 8131, St. Louis, MO (United States); Pinsky, Paul F. [National Cancer Institute, Bethesda, MD (United States); Duan, Fenghai [Brown University School of Public Health, Department of Biostatistics and Center for Statistical Sciences, Providence, RI (United States); Garg, Kavita [University of Colorado School of Medicine, Mail Stop F726, Box 6510, Aurora, CO (United States); Hart, Eric M. [Northwestern University, Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Kazerooni, Ella A. [University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Nath, Hrudaya; Watts, Jubal R. [University of Alabama at Birmingham School of Medicine, Department of Radiology-JTN370, Birmingham, AL (United States); Aberle, Denise R. [David Geffen School of Medicine at UCLA, Department of Radiological Sciences, Los Angeles, CA (United States)

    2017-08-15

    This study retrospectively analyses the screening CT examinations and outcomes of the National Lung Screening Trial (NLST) participants who had interval lung cancer diagnosed within 1 year after a negative CT screen and before the next annual screen. The screening CTs of all 44 participants diagnosed with interval lung cancer (cases) were matched with negative CT screens of participants who did not develop lung cancer (controls). A majority consensus process was used to classify each CT screen as positive or negative according to the NLST criteria and to estimate the likelihood that any abnormalities detected retrospectively were due to lung cancer. By retrospective review, 40/44 cases (91%) and 17/44 controls (39%) met the NLST criteria for a positive screen (P < 0.001). Cases had higher estimated likelihood of lung cancer (P < 0.001). Abnormalities included pulmonary nodules ≥4 mm (n = 16), mediastinal (n = 8) and hilar (n = 6) masses, and bronchial lesions (n = 6). Cancers were stage III or IV at diagnosis in 32/44 cases (73%); 37/44 patients (84%) died of lung cancer, compared to 225/649 (35%) for all screen-detected cancers (P < 0.0001). Most cases met the NLST criteria for a positive screen. Awareness of missed abnormalities and interpretation errors may aid lung cancer identification in CT screening. (orig.)

  16. Radiographic and radionuclide lung perfusion imaging in healthy calves and calves naturally infected with bovine respiratory syncytial virus

    International Nuclear Information System (INIS)

    Verhoeff, J.; Brom, W.E. van den; Ingh, T.S.G.A.M. van den

    1992-01-01

    Nine calves between three and 18 weeks old with serologically confirmed natural bovine respiratory syncytial virus infection were examined clinically, radiographically and by radionuclide lung perfusion imaging. The results were compared with those from seven healthy calves. The diseased calves were euthanased and examined pathologically, virologically and bacteriologically. The clinical signs indicated that the disease was in an acute stage. Radiography of the diseased animals revealed cysts, corresponding morphologically with bullous emphysema, and infiltrations roughly corresponding in distribution with atelectatic and, or, pneumonic areas. Radionuclide lung perfusion imaging revealed no perfusion shifts between the left and right lungs and a normal perfusion pattern in five of the nine diseased calves. The abnormalities in the perfusion patterns of three calves were probably caused by anatomical disorders such as cysts and pleural adhesions, but no cause of the abnormality could be found in one calf. These findings suggest that in calves infected with bovine respiratory syncytial virus, the normal perfusion pattern is maintained until anatomical disorders occur. The pathological examination and radiography revealed that the cranioventral lung fields were particularly poorly ventilated. This finding and the normal perfusion pattern indicate that these parts of the lungs are probably the sites where shuntings and perfusion-ventilation mismatchings occur

  17. First Danish experience with ex vivo lung perfusion of donor lungs before transplantation

    DEFF Research Database (Denmark)

    Henriksen, Ian Sune Iversen; Møller-Sørensen, Hasse; Møller, Christian Holdfold

    2014-01-01

    INTRODUCTION: The number of lung transplantations is limited by a general lack of donor organs. Ex vivo lung perfusion (EVLP) is a novel method to optimise and evaluate marginal donor lungs prior to transplantation. We describe our experiences with EVLP in Denmark during the first year after its...... introduction. MATERIAL AND METHODS: The study was conducted by prospective registration of donor offers and lung transplantations in Denmark from 1 May 2012 to 30 April 2013. Donor lungs without any contraindications were transplanted in the traditional manner. Taken for EVLP were donor lungs that were...... otherwise considered transplantable, but failed to meet the usual criteria due to possible contusions or because they were from donors with sepsis or unable to pass the oxygenation test. RESULTS: In the study period, seven of 33 Danish lung transplantations were made possible due to EVLP. One patient died...

  18. Assessment value of quantitative indexes of pancreatic CT perfusion scanning for malignant degree of pancreatic cancer

    Directory of Open Access Journals (Sweden)

    Jiang-Xia Lei

    2016-10-01

    Full Text Available Objective: To analyze the assessment value of the quantitative indexes of pancreatic CT perfusion scanning for malignant degree of pancreatic cancer. Methods: A total of 58 patients with space-occupying pancreatic lesions were divided into 20 patients with pancreatic cancer and 38 patients with benign pancreatic lesions after pancreatic CT perfusion. Patients with pancreatic cancer received palliative surgery, and the cancer tissue and para-carcinoma tissue specimens were collected during operation. The differences in pancreatic CT perfusion scanning parameter values and serum tumor marker levels were compared between patients with pancreatic cancer and patients with benign pancreatic lesions, mRNA expression levels of malignant molecules in pancreatic cancer tissue and para-carcinoma tissue were further determined, and the correlation between pancreatic CT perfusion scanning parameter values and malignant degree of pancreatic cancer was analyzed. Results: CT perfusion scanning BF, BV and Per values of patients with pancreatic cancer were lower than those of patients with benign pancreatic lesions; serum CA19-9, CEA, CA125 and CA242 levels were higher than those of patients with benign pancreatic lesions (P<0.05; mRNA expression levels of Bcl-2, Bcl-xL and survivin in pancreatic cancer tissue samples were higher than those in paracarcinoma tissue samples, and mRNA expression levels of P53 and Bax were lower than those in para-carcinoma tissue samples (P<0.05; CT perfusion scanning parameters BF, BV and Per values of patients with pancreatic cancer were negatively correlated with CA19-9, CEA, CA125 and CA242 levels in serum as well as mRNA expression levels of Bcl-2, Bcl-xL and survivin in pancreatic cancer tissue, and positively correlated with mRNA expression levels of P53 and Bax in pancreatic cancer tissue (P<0.05. Conclusions: Pancreatic CT perfusion scanning is a reliable way to judge the malignant degree of pancreatic cancer and plays a

  19. Systemic Air Embolism After CT-guided Lung Biopsy

    Science.gov (United States)

    2017-11-27

    Patients Who Underwent Percutaneous Lung Biopsy Under CT Guidance; Patients Who Presented Systemic Air Embolism After Percutaneous Lung Biopsy Under CT Guidance Depicted at the Time of the Procedure on a Whole Thoracic CT

  20. The correlation of CT perfusion imaging with microvessel density and vascular endothelial growth factor in hepatic alveolar echinococcosis

    International Nuclear Information System (INIS)

    Wang Jing; Ren Bo; Liu Wenya; Wen Hao; Qing Song; Xie Weidong; Sun Yajing; Wang Haitao

    2011-01-01

    Objective: To explore the correlation of CT perfusion imaging with microvessel density (MVD) and vascular endothelial growth factor (VEGF) in hepatic alveolar echinococcosis (HAE). Methods: Multi-slice spiral CT perfusion imaging was performed in 27 patients with HAE. Time-density curves(TDC) of the HAE peripheral area was drawn from the region of interest (ROI) with perfusion functional software. CT perfusion parameters including blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were calculated. MVD and VEGF expression of pathological specimens were examined by immunohistochemical staining with anti-CD34, anti-VEGF monoclonal antibody. The CT perfusion parameters, MVD and VEGF were compared in different types of TDC with t test. The correlation of CT perfusion parameters with MVD and VEGF were analyzed with Spearman test. Results: In this group, 21 cases which TDC lower than that of the liver were classified as type Ⅰ, the others 6 cases TDC higher than the liver were of type Ⅱ TDC. TDC perfusion parameters of the two types were as follows, BF: (111.7±27.6), (158.9±39.5) ml · 100 g -1 · min -1 , BV: (15.1±6.2) , (26.8±8.4) ml/100 g, MTT: (7.0±4.4), (7.7±3.1) s, PS: (51.7±17.3), (51.0±20.5) ml ·100 g -1 · min -1 . The significant differences of BF, BV and MVD [(20.5±5.4)/HP, (37.2±7.5)/HP, respectively] were found between two types (t=-7.897, -18.783, -5.223, P 0.05). The correlation was found between the MVD and BF and BV in the type Ⅱ TDC group (r=0.789 and 0.878, respectively) and no correlation was found between MVD and each CT perfusion parameters in the type Ⅰ TDC group (P>0.05). There was no correlation between the VEGF expression and CT perfusion parameters in two types of TDC (P>0.05). Conclusion: CT perfusion imaging with different type of TDC reflected different situation of angiogenesis in HAE peripheral area, which could be a potential technique to illustrate the

  1. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  2. Correlation between CT perfusion and vascular endothelial growth factor in neoplasm of head and neck

    International Nuclear Information System (INIS)

    Yang Zhiyun; Meng Quanfei; Xu Qiaolan; Li Shurong; Yan Chaogui; Xie Hongbo; Yang Xufeng; Peng Qian; Lai Yingrong

    2007-01-01

    Objective: To investigate the correlation between the CT perfusion and microvessel density (MVD), expression of vascular endothelial growth factor (VEGF) in neoplasm of head and neck. Methods: Eighty-eight lesions of head and neck were scanned by spiral CT. The largest axial surface of the mass was searched on unenhanced imaging, and at this level the dynamic contrast enhanced scan series was acquired. Time-density curves (TDC) were created from circular or oval regions of the interest drawn over the mass, target artery by Toshiba Xpress/SX spiral CT with perfusion functional software. The parameters were measured including: peak height (PH), peak time (PT), mean transit time (MTT), contrast enhancement ratio (RPH), and perfusion flow (PF). Histopathological slides of 35 masses were carefully prepared for the anti-CD34 and VEGF immunohistochemical staining and tumor microvessel density and calculation of VEGF expression scores. The parameters of CT perfusion were correlatively study with MVD and VEGF. Results: (1) The TDC of CT perfusion imaging could be classified into 3 types. The TDC of 53/77 (68.9%) malignant tumors presented the type with rapid ascending and rapid descending after injecting contrast. The TDC of 6/9 malignant lymphomas showed low platform curve o (2)The PF median of thyroid carcinoma was 82. 2(41.0,183.4)ml·min -1 ·100 g -1 . There was significantly difference in the parameters of CT perfusion among thyroid carcinoma and squamous cell cancer (Median 23.8 (7.0, 108.4) ml·min -1 ·100 g -1 ) and lymphomas (Median 24.5 (13.2, 78.6) ml·min -1 ·100 g -1 ). (3) MVD in benign tumors was (44.7±3.4), and in malignant tumors, it is (49.6±14.8). There was no significantly difference in MVD between benign and malignant tumors. High VEGF expression was found in 15 malignant tumors and 1 benign tumors, low VEGF expression was found in 9 malignant tumors and 10 benign tumors. (4)There were no significantly difference in VEGF expression and MVD. There

  3. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    International Nuclear Information System (INIS)

    Sinnatamby, R.; Antoun, N.A.; Freer, C.E.L.; Miles, K.A.; Hodges, J.R.

    1996-01-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using 99m Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  4. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sinnatamby, R. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Antoun, N.A. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Freer, C.E.L. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Miles, K.A. [Dept. of Nuclear Medicine, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Hodges, J.R. [Dept. of Neurology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom)

    1996-04-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using {sup 99m}Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  5. Dynamic CT perfusion imaging of the myocardium: a technical note on improvement of image quality.

    Directory of Open Access Journals (Sweden)

    Daniela Muenzel

    Full Text Available OBJECTIVE: To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI by using motion compensation and a spatio-temporal filter. METHODS: Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT. Data from two different patients-with and without myocardial perfusion defects-were evaluated to illustrate potential improvements for MPI (institutional review board approved. Three datasets for each patient were generated: (i original data (ii motion compensated data and (iii motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. RESULTS: The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. CONCLUSION: The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.

  6. CT perfusion for determination of pharmacologically mediated blood flow changes in an animal tumor model.

    Science.gov (United States)

    Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum

    2007-06-01

    To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible

  7. Evaluation of Tl-201 lung uptake and impairment of pulmonary perfusion on scintigraphies in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Koizumi, Tomonori; Kubo, Keishi

    2000-01-01

    Tl-201 lung uptake in 74 patients (85 lesions) and pulmonary perfusion in 105 patients were studied to evaluate clinical usefulness of Tl-201 lung uptake and perfusion lung scintigraphy in pulmonary tuberculosis, using a scintillation camera with a mini-computer system. As indices of Tl-201 lung uptake, lung (lesion) to upper mediastinum uptake ratio (L/M) and visual grading were used. L/M in pulmonary tuberculosis was 1.96±0.66, which was significantly larger than 1.04±0.24 in healthy controls and lower than that in heart diseases with left heart failure and idiopathic interstitial pneumonia, and showed no significant differences with that in acute pneumonia, pyothorax, primary lung cancer and malignant mediastinal tumor. L/M in pulmonary tuberculosis did not correlate with CRP, erythrocyte sedimentation rate, Gaffky number of sputum and body temperature. It correlated with the type of pulmonary tuberculosis according to the Gakken Classification reflecting the disease activity. It was larger in the exudative type, caseo-infiltrative one, disseminated one, one with cavity in infiltrative lesion than the fibro-caseous one. On perfusion lung scintigram, impairment of pulmonary perfusion larger than area of the entire unilateral lung was observed in 68 cases (64.8%). Area of hypoperfused lung field, which correlated with % vital capacity (r=0.60, p=0.0002) and PaO 2 (r=0.39,p=0.0024), was significantly larger in patients with silicosis and those with bilateral pleural involvements such as pleural callosity than in those with type III according to the Gakkai Classification. Most of the patients showed decreased pulmonary perfusion and Tl-201 accumulation of which grade reflects the disease activity in active tuberculous lesion. Patients with miliary tuberculosis and those with silicotuberculosis showed diffuse Tl-201 accumulation in the both lungs. Tl-201 lung scintigraphy seems to be useful for visualizing active tuberculous lesions, particularly the ones that

  8. Dependent lung opacity at thin-section CT: evaluation by spirometrically-gated CT of the influence of lung volume

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Sohn, Choon Hee; Choi, Pil Jo; Webb, W. Richard

    2002-01-01

    To evaluate the influence of lung volume on dependent lung opacity seen at thin-section CT. In thirteen healthy volunteers, thin-section CT scans were performed at three levels (upper, mid, and lower portion of the lung) and at different lung volumes (10, 30, 50, and 100% vital capacity), using spirometric gated CT. Using a three-point scale, two radiologists determined whether dependent opacity was present, and estimated its degree. Regional lung attenuation at a level 2 cm above the diaphragm was determined using semiautomatic segmentation, and the diameter of a branch of the right lower posterior basal segmental artery was measured at each different vital capacity. At all three anatomic levels, dependent opacity occurred significantly more often at lower vital capacities (10, 30%) than at 100% vital capacity (p = 0.001). Visually estimated dependent opacity was significantly related to regional lung attenuation (p < 0.0001), which in dependent areas progressively increased as vital capacity decreased (p < 0.0001). The presence of dependent opacity and regional lung attenuation of a dependent area correlated significantly with increased diameter of a segmental arterial branch (r = 0.493 and p = 0.0002; r = 0.486 and p 0.0003, respectively). Visual estimation and CT measurements of dependent opacity obtained by semiautomatic segmentation are significantly influenced by lung volume and are related to vascular diameter

  9. Whole brain CT perfusion deficits using 320-detector-row CT scanner in TIA patients are associated with ABCD2 score.

    Science.gov (United States)

    Mehta, Bijal K; Mustafa, Ghulam; McMurtray, Aaron; Masud, Mohammed W; Gunukula, Sameer K; Kamal, Haris; Kandel, Amit; Beltagy, Abdelrahman; Li, Ping

    2014-01-01

    Transient ischemic attacks (TIA) are cerebral ischemic events without infarction. The uses of CT perfusion (CTP) techniques such as cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT) and cerebral blood flow (CBF) provide real time data about ischemia. It has been shown that CTP changes occur in less sensitive CTP scanners in patients with TIA. Larger detector row CTP (whole brain perfusion studies) may show that CTP abnormalities are more prevalent than previously noted. It is also unclear if these changes are associated with TIA severity. To demonstrate that TIA patients are associated with perfusion deficits using whole brain 320-detector-row CT perfusion, and to determine an association between ABCD2 score and perfusion deficit using whole brain perfusion. We retrospectively reviewed all TIA patients for CTP deficits from 2008-2010. Perfusion imaging was reviewed at admission; and it was determined if a perfusion deficit was present along with vascular territory involved. Of 364 TIA patients, 62 patients had CTP deficits. The largest group of patients had MCA territory involved with 48 of 62 patients (77.42%). The most common perfusion abnormality was increased TTP with 46 patients (74.19%). The ABCD2 score was reviewed in association with perfusion deficit. Increased age >60, severe hypertension (>180/100 mmHg), patients with speech abnormalities, and duration of symptoms >10 min were associated with a perfusion deficit but history of diabetes or minimal/moderate hypertension (140/90-179/99 mmHg) was not. There was no association between motor deficit and perfusion abnormality. Perfusion deficits are found in TIA patients using whole brain CTP and associated with components of the ABCD2 score.

  10. Solitary pulmonary nodules: Comparison of dynamic first-pass contrast-enhanced perfusion area-detector CT, dynamic first-pass contrast-enhanced MR imaging, and FDG PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Seki, Shinichiro; Tsubakimoto, Maho; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2015-02-01

    To prospectively compare the capabilities of dynamic perfusion area-detector computed tomography (CT), dynamic magnetic resonance (MR) imaging, and positron emission tomography (PET) combined with CT (PET/CT) with use of fluorine 18 fluorodeoxyglucose (FDG) for the diagnosis of solitary pulmonary nodules. The institutional review board approved this study, and written informed consent was obtained from each subject. A total of 198 consecutive patients with 218 nodules prospectively underwent dynamic perfusion area-detector CT, dynamic MR imaging, FDG PET/CT, and microbacterial and/or pathologic examinations. Nodules were classified into three groups: malignant nodules (n = 133) and benign nodules with low (n = 53) or high (n = 32) biologic activity. Total perfusion was determined with dual-input maximum slope models at area-detector CT, maximum and slope of enhancement ratio at MR imaging, and maximum standardized uptake value (SUVmax) at PET/CT. Next, all indexes for malignant and benign nodules were compared with the Tukey honest significant difference test. Then, receiver operating characteristic analysis was performed for each index. Finally, sensitivity, specificity, and accuracy were compared with the McNemar test. All indexes showed significant differences between malignant nodules and benign nodules with low biologic activity (P Dynamic perfusion area-detector CT is more specific and accurate than dynamic MR imaging and FDG PET/CT in the diagnosis of solitary pulmonary nodules in routine clinical practice. © RSNA, 2014.

  11. Clinical application of lower extremity CTA and lower extremity perfusion CT as a method of diagnostic for lower extremity atherosclerotic obliterans

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Il Bong; Dong, Kyung Rae [Dept. Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Goo, Eun Hoe [Dept. Radiological Science, Cheongju University, Cheongju (Korea, Republic of)

    2016-11-15

    The purpose of this study was to assess clinical application of lower extremity CTA and lower extremity perfusion CT as a method of diagnostic for lower extremity atherosclerotic obliterans. From January to July 2016, 30 patients (mean age, 68) were studied with lower extremity CTA and lower extremity perfusion CT. 128 channel multi-detector row CT scans were acquired with a CT scanner (SOMATOM Definition Flash, Siemens medical solution, Germany) of lower extremity perfusion CT and lower extremity CTA. Acquired images were reconstructed with 3D workstation (Leonardo, Siemens, Germany). Site of lower extremity arterial occlusive and stenosis lesions were detected superficial femoral artery 36.6%, popliteal artery 23.4%, external iliac artery 16.7%, common femoral artery 13.3%, peroneal artery 10%. The mean total DLP comparison of lower extremity perfusion CT and lower extremity CTA, 650 mGy-cm and 675 mGy-cm, respectively. Lower extremity perfusion CT and lower extremity CTA were realized that were never be two examination that were exactly the same legions. Future through the development of lower extremity perfusion CT soft ware programs suggest possible clinical applications.

  12. Measurement of ventilation- and perfusion-mediated cooling during laser ablation in ex vivo human lung tumors

    Energy Technology Data Exchange (ETDEWEB)

    Vietze, Andrea, E-mail: anvie@gmx.de [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany); Koch, Franziska, E-mail: franzi_koch@hotmail.com [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany); Laskowski, Ulrich, E-mail: ulrich.laskowski@klinikum-luedenscheid.de [Department of Vascular and Thoracic Surgery, Klinikum Luedenscheid, Paulmannshoeher Strasse 14, 58515 Luedenscheid (Germany); Linder, Albert, E-mail: albert.linder@klinikum-bremen-ost.de [Department of Thoracic Surgery, Klinikum Bremen-Ost, Zuericher Strasse 40, 28325 Bremen (Germany); Hosten, Norbert, E-mail: hosten@uni-greifswald.de [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany)

    2011-11-15

    Purpose: Perfusion-mediated tissue cooling has often been described in the literature for thermal ablation therapies of liver tumors. The objective of this study was to investigate the cooling effects of both perfusion and ventilation during laser ablation of lung malignancies. Materials and methods: An ex vivo lung model was used to maintain near physiological conditions for the specimens. Fourteen human lung lobes containing only primary lung tumors (non-small cell lung cancer) were used. Laser ablation was carried out using a Nd:YAG laser with a wavelength of 1064 nm and laser fibers with 30 mm diffusing tips. Continuous invasive temperature measurement in 10 mm distance from the laser fiber was performed. Laser power was increased at 2 W increments starting at 10 W up to a maximum power of 12-20 W until a temperature plateau around 60 deg. C was reached at one sensor. Ventilation and perfusion were discontinued for 6 min each to assess their effects on temperature development. Results: The experiments lead to 25 usable temperature profiles. A significant temperature increase was observed for both discontinued ventilation and perfusion. In 6 min without perfusion, the temperature rose about 5.5 deg. C (mean value, P < 0.05); without ventilation it increased about 7.0 deg. C (mean value, P < 0.05). Conclusion: Ventilation- and perfusion-mediated tissue cooling are significant influencing factors on temperature development during thermal ablation. They should be taken into account during the planning and preparation of minimally invasive lung tumor treatment in order to achieve complete ablation.

  13. SU-E-I-36: A KWIC and Dirty Look at Dose Savings and Perfusion Metrics in Simulated CT Neuro Perfusion Exams

    International Nuclear Information System (INIS)

    Hoffman, J; Martin, T; Young, S; McNitt-Gray, M; Wang, D

    2015-01-01

    Purpose: CT neuro perfusion scans are one of the highest dose exams. Methods to reduce dose include decreasing the number of projections acquired per gantry rotation, however conventional reconstruction of such scans leads to sampling artifacts. In this study we investigated a projection view-sharing reconstruction algorithm used in dynamic MRI – “K-space Weighted Image Contrast” (KWIC) – applied to simulated perfusion exams and evaluated dose savings and impacts on perfusion metrics. Methods: A FORBILD head phantom containing simulated time-varying objects was developed and a set of parallel-beam CT projection data was created. The simulated scans were 60 seconds long, 1152 projections per turn, with a rotation time of one second. No noise was simulated. 5mm, 10mm, and 50mm objects were modeled in the brain. A baseline, “full dose” simulation used all projections and reduced dose cases were simulated by downsampling the number of projections per turn from 1152 to 576 (50% dose), 288 (25% dose), and 144 (12.5% dose). KWIC was further evaluated at 72 projections per rotation (6.25%). One image per second was reconstructed using filtered backprojection (FBP) and KWIC. KWIC reconstructions utilized view cores of 36, 72, 144, and 288 views and 16, 8, 4, and 2 subapertures respectively. From the reconstructed images, time-to-peak (TTP), cerebral blood flow (CBF) and the FWHM of the perfusion curve were calculated and compared against reference values from the full-dose FBP data. Results: TTP, CBF, and the FWHM were unaffected by dose reduction (to 12.5%) and reconstruction method, however image quality was improved when using KWIC. Conclusion: This pilot study suggests that KWIC preserves image quality and perfusion metrics when under-sampling projections and that the unique contrast weighting of KWIC could provided substantial dose-savings for perfusion CT scans. Evaluation of KWIC in clinical CT data will be performed in the near future. R01 EB014922, NCI

  14. SU-E-I-36: A KWIC and Dirty Look at Dose Savings and Perfusion Metrics in Simulated CT Neuro Perfusion Exams

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, J; Martin, T; Young, S; McNitt-Gray, M; Wang, D [UCLA School of Medicine, Los Angeles, CA (United States)

    2015-06-15

    Purpose: CT neuro perfusion scans are one of the highest dose exams. Methods to reduce dose include decreasing the number of projections acquired per gantry rotation, however conventional reconstruction of such scans leads to sampling artifacts. In this study we investigated a projection view-sharing reconstruction algorithm used in dynamic MRI – “K-space Weighted Image Contrast” (KWIC) – applied to simulated perfusion exams and evaluated dose savings and impacts on perfusion metrics. Methods: A FORBILD head phantom containing simulated time-varying objects was developed and a set of parallel-beam CT projection data was created. The simulated scans were 60 seconds long, 1152 projections per turn, with a rotation time of one second. No noise was simulated. 5mm, 10mm, and 50mm objects were modeled in the brain. A baseline, “full dose” simulation used all projections and reduced dose cases were simulated by downsampling the number of projections per turn from 1152 to 576 (50% dose), 288 (25% dose), and 144 (12.5% dose). KWIC was further evaluated at 72 projections per rotation (6.25%). One image per second was reconstructed using filtered backprojection (FBP) and KWIC. KWIC reconstructions utilized view cores of 36, 72, 144, and 288 views and 16, 8, 4, and 2 subapertures respectively. From the reconstructed images, time-to-peak (TTP), cerebral blood flow (CBF) and the FWHM of the perfusion curve were calculated and compared against reference values from the full-dose FBP data. Results: TTP, CBF, and the FWHM were unaffected by dose reduction (to 12.5%) and reconstruction method, however image quality was improved when using KWIC. Conclusion: This pilot study suggests that KWIC preserves image quality and perfusion metrics when under-sampling projections and that the unique contrast weighting of KWIC could provided substantial dose-savings for perfusion CT scans. Evaluation of KWIC in clinical CT data will be performed in the near future. R01 EB014922, NCI

  15. Estimation of pulmonary hypertension in lung and valvular heart diseases by perfusion lung scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige [Shinshu Univ., Matsumoto, Nagano (Japan). School of Allied Medical Sciences; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hirosi; Koizumi, Tomonori; Kubo, Keisi; Sekiguchi, Morie; Yano, Kesato

    1999-06-01

    To estimate pulmonary hypertension, we measured postural differences in pulmonary blood flow for the lateral decubitus positions on perfusion lung scintigrams with Tc-99 m macro-aggregated albumin, applying the method devised by Tanaka et al (Eur J Nucl Med 17: 320-326, 1990). Utilizing a scintillation camera coupled to a minicomputer system, changes in the distribution of pulmonary blood flow caused by gravitational effects, namely, changes in the total count ratios for the right lung versus the left lung in the right and left lateral decubitus positions (R/L), were obtained for 44 patients with lung disease, 95 patients with valvular heart disease, and 23 normal subjects. Mean standard deviation in the R/L ratios was 3.09{+-}1.28 for the normal subjects, 1.97{+-}0.89 for the patients with lung disease, and 1.59{+-}0.59 for the patients with valvular heart disease. The R/L ratios correlated with mean pulmonary arterial pressure and cardio-thoracic ratios in the lung disease and valvular heart disease groups, with pulmonary arteriolar resistance in the former, and with pulmonary capillary wedge pressure in the latter. Defining pulmonary hypertension (>20 mmHg) as an R/L ratio of less than 1.81, which is the mean-1 standard deviation for normal subjects, the sensitivity and the specificity of the R/L ratio for the diagnosis of pulmonary hypertension were 62.9% and 76.2%, respectively, for the lung disease patients, and 80.3% and 61.8%, respectively, for the valvular heart disease patients. This method seems to be useful for the pathophysiologic evaluation of pulmonary perfusion in cases of lung disease and valvular heart disease. (author)

  16. Estimation of pulmonary hypertension in lung and valvular heart diseases by perfusion lung scintigraphy

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hirosi; Koizumi, Tomonori; Kubo, Keisi; Sekiguchi, Morie; Yano, Kesato

    1999-01-01

    To estimate pulmonary hypertension, we measured postural differences in pulmonary blood flow for the lateral decubitus positions on perfusion lung scintigrams with Tc-99 m macro-aggregated albumin, applying the method devised by Tanaka et al (Eur J Nucl Med 17: 320-326, 1990). Utilizing a scintillation camera coupled to a minicomputer system, changes in the distribution of pulmonary blood flow caused by gravitational effects, namely, changes in the total count ratios for the right lung versus the left lung in the right and left lateral decubitus positions (R/L), were obtained for 44 patients with lung disease, 95 patients with valvular heart disease, and 23 normal subjects. Mean standard deviation in the R/L ratios was 3.09±1.28 for the normal subjects, 1.97±0.89 for the patients with lung disease, and 1.59±0.59 for the patients with valvular heart disease. The R/L ratios correlated with mean pulmonary arterial pressure and cardio-thoracic ratios in the lung disease and valvular heart disease groups, with pulmonary arteriolar resistance in the former, and with pulmonary capillary wedge pressure in the latter. Defining pulmonary hypertension (>20 mmHg) as an R/L ratio of less than 1.81, which is the mean-1 standard deviation for normal subjects, the sensitivity and the specificity of the R/L ratio for the diagnosis of pulmonary hypertension were 62.9% and 76.2%, respectively, for the lung disease patients, and 80.3% and 61.8%, respectively, for the valvular heart disease patients. This method seems to be useful for the pathophysiologic evaluation of pulmonary perfusion in cases of lung disease and valvular heart disease. (author)

  17. Measurement of lung volumes : usefulness of spiral CT

    International Nuclear Information System (INIS)

    Kang, Ho Yeong; Kwak, Byung Kook; Lee, Sang Yoon; Kim, Soo Ran; Lee, Shin Hyung; Lee, Chang Joon; Park, In Won

    1996-01-01

    To evaluate the usefulness of spiral CT in the measurement of lung volumes. Fifteen healthy volunteers were studied by both spirometer and spiral CT at full inspiration and expiration in order to correlated their results, including total lung capacity (TLC), vital capacity (VC) and residual volume (RV). 3-D images were reconstructed from spiral CT, and we measured lung volumes at a corresponding CT window range ; their volumes were compared with the pulmonary function test (paired t-test). The window range corresponding to TLC was from -1000HU to -150HU (p=0.279, r=0.986), and for VC from -910HU to -800HU (p=0.366, r=0.954) in full-inspiratory CT. The optimal window range for RV in full-expiratory CT was from -1000HU to -450HU (p=0.757, r=0.777), and TLC-VC in full-inspiratory CT was also calculated (p=0.843, r=0.847). Spiral CT at full inspiration can used to lung volumes such as TLC, VC and RV

  18. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    Directory of Open Access Journals (Sweden)

    G. J. Pelgrim

    2016-01-01

    Full Text Available Technological advances in magnetic resonance imaging (MRI and computed tomography (CT, including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET. This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD, as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings.

  19. Commercial software upgrades may significantly alter Perfusion CT parameter values in colorectal cancer

    International Nuclear Information System (INIS)

    Goh, Vicky; Shastry, Manu; Endozo, Raymondo; Groves, Ashley M.; Engledow, Alec; Peck, Jacqui; Reston, Jonathan; Wellsted, David M.; Rodriguez-Justo, Manuel; Taylor, Stuart A.; Halligan, Steve

    2011-01-01

    To determine how commercial software platform upgrades impact on derived parameters for colorectal cancer. Following ethical approval, 30 patients with suspected colorectal cancer underwent Perfusion CT using integrated 64 detector PET/CT before surgery. Analysis was performed using software based on modified distributed parameter analysis (Perfusion software version 4; Perfusion 4.0), then repeated using the previous version (Perfusion software version 3; Perfusion 3.0). Tumour blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were determined for identical regions-of-interest. Slice-by-slice and 'whole tumour' variance was assessed by Bland-Altman analysis. Mean BF, BV and PS was 20.4%, 59.5%, and 106% higher, and MTT 14.3% shorter for Perfusion 4.0 than Perfusion 3.0. The mean difference (95% limits of agreement) were +13.5 (-44.9 to 72.0), +2.61 (-0.06 to 5.28), -1.23 (-6.83 to 4.36), and +14.2 (-4.43 to 32.8) for BF, BV, MTT and PS respectively. Within subject coefficient of variation was 36.6%, 38.0%, 27.4% and 60.6% for BF, BV, MTT and PS respectively indicating moderate to poor agreement. Software version upgrades of the same software platform may result in significantly different parameter values, requiring adjustments for cross-version comparison. (orig.)

  20. Arterio-venous anastomoses in mice affect perfusion measurements with dynamic contrast enhanced CT

    International Nuclear Information System (INIS)

    Gabra, Peter; Lee, Ting-Yim; Shen, Gang; Xuan, Jim

    2010-01-01

    Accurate measurement of perfusion with dynamic contrast enhanced CT requires an arterial input curve (AIC) uncontaminated by venous sources. Arterio-venous anastomoses (AVAs) are sources of contamination if contrast is injected intravenously. We seek to identify AVAs in mice and associated errors in perfusion measurements. Six transgenic mice with spontaneous prostate tumor were scanned with a micro-CT scanner (GE Healthcare (GE)) using a high resolution anatomical and a lower resolution perfusion protocol. For the anatomical protocol, a CT scan was performed during injection of an iodinated contrast agent (Hypaque) into a tail vein. Images covering the thoracic, abdominal and pelvic regions at an isotropic resolution of 175 µm were reconstructed and rendered in 3D to show the arterial and venous tree (Advantage Window, GE). For the perfusion protocol, each mouse was continuously scanned for 40 s and the contrast agent (Hypaque) was injected via a tail vein 5 s into scanning. Tumor images were reconstructed every second. Tumor blood flow (BF) and volume (BV) maps were calculated with CT perfusion software (GE) using AIC measured either from abdominal aorta (AA) or tail (caudal) artery (TA). In all mice, there was an AVA from the bifurcation of the inferior vena cava to the tail artery shunting venous blood and portion of the contrast agent injected into the tail vein into the TA. Contrast arrival time at the TA preceded that at the AA by 3.3 ± 0.5 s (P < 0.05). Mean tumor BV and BF values calculated with AA versus TA were 10.0 ± 1.8 versus 4.8 ± 2.1 ml (100 g) −1 (P < 0.05) and 108.8 ± 26.5 versus 33.0 ± 8.5 ml min −1 100 g −1 (P < 0.05), respectively. AVA in the murine pelvic region can result in inaccurate and more variable measurements of pelvic organ/tissue perfusion when the tail artery is used as the AIC

  1. Accuracy and feasibility of dynamic contrast-enhanced 3D MR imaging in the assessment of lung perfusion: comparison with Tc-99 MAA perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yilmaz, E.; Akkoclu, A.; Degirmenci, B.; Cooper, R.A.; Sengun, B.; Gulcu, A.; Osma, E.; Ucan, E.S.

    2005-01-01

    AIM: The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS: In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 deg ; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1 s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS: Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION: Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities

  2. Evaluation of portal hypertension: a comparison of the use of liver perfusion CT with wedge hepatic venous pressure and hepatic

    International Nuclear Information System (INIS)

    Chung, Dong Jin; Kim, Young Joong; Park, Yong Sung; Lee, Tae Hee; Kim, Chong Soo; Kang, Heung Keun

    2008-01-01

    We compared the hepatic perfusion indices obtained using hepatic perfusion CT with the wedge hepatic venous pressure (WHVP) and hepatic venous pressure gradient (HVPG) to determine the efficacy of the use of liver perfusion CT for the evaluation of portal hypertension. Thirty-five patients with liver cirrhosis underwent hepatic vein catheterization to measure WHVP and HVPG and underwent a liver perfusion CT examination. Arterial perfusion, portal perfusion, total perfusion and the hepatic perfusion index (HPI) were calculated by the methods described by Miles and Blomlely. The overall correlation coefficients (r) between the perfusion indices and WHVP and HVPG were calculated. An additional correlation coefficient of 23 alcoholic cirrhosis patients was calculated. Using Blomley's equation, HPI had a positive correlation with WHVP (r = .471; ρ < .05) and HVPG (r = .482; ρ < .05). For the alcoholic liver cirrhosis patients, HPI had a higher positive correlation with WHVP (r = .500; ρ < .05) and HVPG (r = .539; ρ < .05) than for the non-alcoholic cirrhosis patients. There was no statistical difference between the use of Miles' equation and Blomley's equation for the evaluation of portal hypertension. This preliminary study showed that HPI positively correlated with WHVP and HVPG, especially in alcoholic cirrhosis patients. Liver perfusion CT may be useful in the evaluation of portal hypertension

  3. A 4D Digital Phantom for Patient-Specific Simulation of Brain CT Perfusion Protocols

    NARCIS (Netherlands)

    Boom, R. van den; Manniesing, R.; Oei, M.T.H.; Woude, W.J. van der; Smit, E.J.; Laue, H.O.A.; Ginneken, B. van; Prokop, M.

    2014-01-01

    Purpose Optimizing CT brain perfusion protocols is a challenge because of the complex interaction between image acquisition, calculation of perfusion data and patient hemodynamics. Several digital phantoms have been developed to avoid unnecessary patient exposure or suboptimum choice of parameters.

  4. Liver perfusion CT during hepatic arteriography for the hepatocellular carcinoma: Dose reduction and quantitative evaluation for normal- and ultralow-dose protocol

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Shingo [Department of Radiology, Dokkyo Medical University Koshigaya Hospital, 2-1-50, Minami-Koshigaya, Koshigaya-shi, Saitama 343-8555 (Japan); Katada, Yoshiaki, E-mail: yoshiaki@dokkyomed.ac.jp [Department of Radiology, Dokkyo Medical University Koshigaya Hospital, 2-1-50, Minami-Koshigaya, Koshigaya-shi, Saitama 343-8555 (Japan); Gohkyu, Masaki; Nakajima, Masahiro; Kawabata, Hideyuki; Nozaki, Miwako [Department of Radiology, Dokkyo Medical University Koshigaya Hospital, 2-1-50, Minami-Koshigaya, Koshigaya-shi, Saitama 343-8555 (Japan)

    2012-12-15

    Objectives: The purpose of this study was to investigate whether substantial reduction of the computed tomography (CT) dose is possible in liver CT perfusion imaging by comparing the results of ultralow-dose CT perfusion imaging with those of conventional CT perfusion imaging the same patients and under the same conditions. Materials and methods: The study was composed following two parts: computer simulation and patients study. In computer simulation, noise was added to the images so that the standard deviation (SD) of the CT values in the liver parenchyma became various values using ImageJ. Time density curves (TDCs) were created from the simulated data, and the influence of difference in the SDs on the shapes of the TDCs was investigated. In the patient study, CT perfusion during intra-arterial injection was performed in 30 consecutive patients undergoing transcatheter arterial chemoembolization. CT perfusion images were acquired twice, at 100 mA (CTDI{sub vol}, 300 mGy) for normal and at 20 mA (CTDI{sub vol}, 60 mGy) for the ultralow radiation doses, under the same conditions. Results: No change was observed in the shape of the TDCs and peak values in the analysis of simulation images. A very good correlation was observed between the normal- and ultralow-dose CT images for all analyzed values (R{sup 2} = 0.9885 for blood flow, 0.9269 for blood volume, and 0.8424 for mean transit time). Conclusions: Our results demonstrated that there was no significant difference in the analysis results of perfusion CT between ultralow-dose CT performed using 20% of the conventional dose and normal-dose CT perfusion.

  5. Ex vivo lung perfusion in clinical lung transplantation--state of the art.

    Science.gov (United States)

    Andreasson, Anders S I; Dark, John H; Fisher, Andrew J

    2014-11-01

    Ex vivo lung perfusion (EVLP) has emerged as a new technique for assessing and potentially reconditioning human donor lungs previously unacceptable for clinical transplantation with the potential to dramatically push the limits of organ acceptability. With the recent introduction of portable EVLP, a new era in lung preservation may be upon us with the opportunity to also limit organ ischaemic times and potentially improve the outcome of donor lungs already deemed acceptable for transplantation. It took over half a century for the technique to evolve from basic theory to semi-automated circuits fit for clinical use that are now rapidly being adopted in transplant centres across the globe. With this field in constant evolution and many unanswered questions remaining, our review serves as an update on the state of the art of EVLP in clinical lung transplantation. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Lung perfusion and emphysema distribution affect the outcome of endobronchial valve therapy

    Directory of Open Access Journals (Sweden)

    Thomsen C

    2016-06-01

    Full Text Available Christian Thomsen,1 Dorothea Theilig,2 Dominik Herzog,1 Alexander Poellinger,2 Felix Doellinger,2 Nils Schreiter,3 Vera Schreiter,2 Dirk Schürmann,1 Bettina Temmesfeld-Wollbrueck,1 Stefan Hippenstiel,1 Norbert Suttorp,1 Ralf-Harto Hubner1 1Department of Internal Medicine/Infectious Diseases and Respiratory Medicine, 2Institute of Radiology, 3Institute of Nuclear Medicine, Charité – Universitätsmedizin Berlin, Berlin, Germany Abstract: The exclusion of collateral ventilation (CV and other factors affect the clinical success of endoscopic lung volume reduction (ELVR. However, despite its benefits, the outcome of ELVR remains difficult to predict. We investigated whether clinical success could be predicted by emphysema distribution assessed by computed tomography scan and baseline perfusion assessed by perfusion scintigraphy. Data from 57 patients with no CV in the target lobe (TL were retrospectively analyzed after ELVR with valves. Pulmonary function tests (PFT, St George’s Respiratory Questionnaire (SGRQ, and 6-minute walk tests (6MWT were performed on patients at baseline. The sample was grouped into high and low levels at the median of TL perfusion, ipsilateral nontarget lobe (INL perfusion, and heterogeneity index (HI. These groups were analyzed for association with changes in outcome parameters from baseline to 3 months follow-up. Compared to baseline, patients showed significant improvements in PFT, SGRQ, and 6MWT (all P≤0.001. TL perfusion was not associated with changes in the outcome. High INL perfusion was significantly associated with increases in 6MWT (P=0.014, and high HI was associated with increases in forced expiratory volume in 1 second (FEV1, (P=0.012. Likewise, there were significant correlations for INL perfusion and improvement of 6MWT (r=0.35, P=0.03 and for HI and improvement in FEV1 (r=0.45, P=0.001. This study reveals new attributes that associate with positive outcomes for patient selection prior to ELVR

  7. Segmentation of Lung Structures in CT

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau

    This thesis proposes and evaluates new algorithms for segmenting various lung structures in computed tomography (CT) images, namely the lungs, airway trees and vessel trees. The main objective of these algorithms is to facilitate a better platform for studying Chronic Obstructive Pulmonary Disease......, 200 randomly selected CT scans were manually evaluated by medical experts, and only negligible or minor errors were found in nine scans. The proposed algorithm has been used to study how changes in smoking behavior affect CT based emphysema quantification. The algorithms for segmenting the airway...

  8. Propofol attenuates oxidant-induced acute lung injury in an isolated perfused rabbit-lung model.

    Science.gov (United States)

    Yumoto, Masato; Nishida, Osamu; Nakamura, Fujio; Katsuya, Hirotada

    2005-01-01

    Reactive oxygen species have been strongly implicated in the pathogenesis of acute lung injury (ALI). Some animal studies suggest that free radical scavengers inhibit the onset of oxidant-induced ALI. Propofol (2,6-diisopropylphenol) is chemically similar to phenol-based free radical scavengers such as the endogenous antioxidant vitamin E. Both in vivo and in vitro studies have suggested that propofol has antioxidant potential. We hypothesized that propofol may attenuate ALI by acting as a free-radical scavenger. We investigated the effects of propofol on oxidant-induced ALI induced by purine and xanthine oxidase (XO), in isolated perfused rabbit lung, in two series of experiments. In series 1, we examined the relationship between the severity of ALI and the presence of hydrogen peroxide (H2O2). In series 2, we evaluated the effects of propofol on attenuating ALI and the dose dependence of these effects. The lungs were perfused for 90 min, and we evaluated the effects on the severity of ALI by monitoring the pulmonary capillary filtration coefficient (Kfc), pulmonary arterial pressure (Ppa), and the pulmonary capillary hydrostatic pressure (Ppc). In series 1, treatment with catalase (an H2O2 scavenger) prior to the addition of purine and XO resulted in complete prevention of ALI, suggesting that H2O2 may be involved closely in the pathogenesis of ALI. In series 2, pretreatment with propofol at concentrations in excess of 0.5 mM significantly inhibited the increases in the Kfc values, and that in excess of 0.75 mM significantly inhibited the increase in the Ppa values. Propofol attenuates oxidant-induced ALI in an isolated perfused rabbit lung model, probably due to its antioxidant action.

  9. Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Yinghua [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Chen, Guang-Hong [Department of Medical Physics and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Hacker, Timothy A.; Raval, Amish N. [Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Van Lysel, Michael S.; Speidel, Michael A., E-mail: speidel@wisc.edu [Department of Medical Physics and Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2014-07-15

    Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan was performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937

  10. Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method

    International Nuclear Information System (INIS)

    Tao, Yinghua; Chen, Guang-Hong; Hacker, Timothy A.; Raval, Amish N.; Van Lysel, Michael S.; Speidel, Michael A.

    2014-01-01

    Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan was performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937

  11. Lung ventilation-perfusion imbalance in pulmonary emphysema: assessment with automated V/Q quotient SPECT.

    Science.gov (United States)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Koike, Hiroaki; Iwanaga, Hideyuki; Tokuda, Osamu; Okada, Munemasa; Matsunaga, Naofumi

    2010-05-01

    Tc-99m-Technegas-MAA single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema.

  12. Studies on the correlation between pre-and post-operative perfusion scintigraphy and differential spirometry in operated lungs

    International Nuclear Information System (INIS)

    Kaseda, Shizuka; Ikeda, Takaaki; Sakai, Tadaaki; Tomaru, Hiroko; Ishihara, Tsuneo; Kikuchi, Keiichi.

    1982-01-01

    For the purpose of clarifying the relationship between the percentage of perfusion and that of vital capacity or oxygen uptake on the affected lung, perfusion scintigraphy using sup(99m)Tc-MAA and differential spirometry were performed in twenty patients including sixteen patients with lung cancer. Both examinations were performed before and after the operation. The results are as follows: (1) There is a significant correlation between the percentage of perfusion and that of vital capacity or oxygen uptake of the affected lung before and after the operation. (2) The estimation of the percentage of vital capacity or oxygen uptake of the affected lung is possible by combining the spirometry and sup(99m)Tc-MAA pulmonary scintigraphy. (author)

  13. Renal hemodynamic changes with aging: a preliminary study using CT perfusion in the healthy elderly.

    Science.gov (United States)

    Zhao, Hong; Gong, Jingshan; Wang, Yan; Zhang, Zuoquan; Qin, Peixin

    2010-01-01

    To investigate renal blood flow perfusion parameter changes associated with aging using multislice spiral computed tomography (CT). This prospective study was approved by the institute's ethics committee for clinical study and written informed consent was obtained from all subjects. Forty-two consecutive patients who underwent abdominal CT without obvious renal abnormality at plain scanning were enrolled in this study. The renal perfusion scan was carried out using 16-slice spiral CT. The Pearson correlation coefficient was used to examine the correlation between perfusion parameter changes with aging. In both the cortex and medulla, blood flow (BF) and blood volume (BV) were negatively correlated with age, while time-to-peak (TTP) value and mean transit time (MTT) showed a positive correlation with age. Changes in BF, TTP, and MTT were found to have a statistically significant correlation with age in both the cortex and medulla, while the correlation between BV and age showed no statistical significance. It is feasible to assess renal hemodynamics changes with aging in the elderly using the current clinically available CT perfusion imaging technology in vivo. It may be helpful in the management of aged patients to familiarize with the renal hemodynamics changes in clinical work-up. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Peritumoral brain edema in intracranial tumor evaluated by CT perfusion imaging

    International Nuclear Information System (INIS)

    Shi Yuxin; Xu Jianfeng

    2005-01-01

    Objective: To semi-quantitatively evaluate the cerebral perfusion in the peritumoral brain edema of cerebral tumors using CT perfusion imaging. Methods: Twenty-one patients with peritumoral brain edema (including pathologically confirmed meningiomas n=4, metastasis n=10, gliomas n=7) were examined by CT perfusion imaging. The regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), and mean transit time (MTT) were calculated for peritumoral brain edema and the contralateralwhite matter. The rCBF and rCBV were compared between peritumoral brain edema and the contralateral white matter. The mean ratios (edema/contralateral white matter) of rCBF and rCBV were compared among the three tumors. Results: The rCBF and rCBV of peritumoral brain edema were significantly lower than those of contralateral white matter in patients with meningiomas and metastasis (rCBF: t=2.92 and 3.82, P 0.05). The mean ratios (edema/contralateralwhite matter) of rCBF and rCBV were not significantly different between meningiomas and metastasis (t=0.23 and 0.73, P>0.05), but both of them were significantly lower than those of gliomas (t=3.05 and 3.37, P<0.01, 0.005). Conclusion: The rCBF and rCBV in peritumoral brain edema were significantly lower than those of contralateral white matter in patients with meningiomas and metastasis, while almost the same with or higher than those of contralateral white matter in patients with gliomas. CT perfusion can provide quantitative information of blood flow in peritumoral brain edema, and is useful in the diagnosis and follow-up of cerebral tumors. (authors)

  15. The evaluation of the degree of impairment of pulmonary perfusion in lung cancer patients treated by radiotherapy by the quantification of nonuniform distribution of lung perfusion scintigraphy SPECT

    International Nuclear Information System (INIS)

    Mitomo, Osamu; Tsunoda, Takashi; Kuwabara, Hidemasa

    2004-01-01

    By means of quantifying the nonuniform distribution of pulmonary perfusion in Lung Perfusion Scintigraphy SPECT (single photon emission tomography), which is called ''SPECT'' for short, we evaluated the degree of functional impairment of pulmonary perfusion in non-operated lung cancer patients treated by the radiotherapy. Sixty-eight patients with non-operated lung cancer treated with radiotherapy, and who either received or did not receive chemotherapy, from February, 1996 to August, 2002, were examined using SPECT within 6 weeks prior to, or within 2 weeks following radiotherapy. This group was called ''irradiated lung cancer patients''. Twenty-six patients, who were called ''follow-up irradiated lung cancer patients'', were reexamined within four weeks after radiotherapy. On the other hand, 323 patients without lung cancer, who were subdivided into four groups; pulmonary, cardiac, cardio-pulmonary, and non-cardiopulmonary. The SPECT was examined in the supine position after infusing Tc-99m-MAA, 185 MBq in a bolus, mainly into an antecubital vein with the patient's arm elevated. From reconstructed SPECT images, the volume of lung as a whole calculated at 10% of thresholds was assumed to be the ''Baseline Lung Perfusion Volume'' (BPV), and the functional volume rates were calculated in 10% threshold widths from 10% to 100% of the threshold. Assuming the total absolute differences in functional volume rate between each subject and the control to be the distribution index of the lung as a whole (D index), we quantified the degree of nonuniform distribution of the lung as a whole in each subject. In the same way, the distribution index of the left or right lung respectively was calculated as D l or D r index assuming the volume of left or right lung were calculated at 10% of the threshold as left or right BPV and calculating the functional volume rates of each lung in 10% threshold widths from 10% to 100% of the threshold. The D index of irradiated lung cancer

  16. Evaluation of portal hypertension: a comparison of the use of liver perfusion CT with wedge hepatic venous pressure and hepatic

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Dong Jin; Kim, Young Joong; Park, Yong Sung; Lee, Tae Hee [University of Konyang College of Medicine, Daejeon (Korea, Republic of); Kim, Chong Soo; Kang, Heung Keun [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2008-09-15

    We compared the hepatic perfusion indices obtained using hepatic perfusion CT with the wedge hepatic venous pressure (WHVP) and hepatic venous pressure gradient (HVPG) to determine the efficacy of the use of liver perfusion CT for the evaluation of portal hypertension. Thirty-five patients with liver cirrhosis underwent hepatic vein catheterization to measure WHVP and HVPG and underwent a liver perfusion CT examination. Arterial perfusion, portal perfusion, total perfusion and the hepatic perfusion index (HPI) were calculated by the methods described by Miles and Blomlely. The overall correlation coefficients (r) between the perfusion indices and WHVP and HVPG were calculated. An additional correlation coefficient of 23 alcoholic cirrhosis patients was calculated. Using Blomley's equation, HPI had a positive correlation with WHVP (r = .471; {rho} < .05) and HVPG (r = .482; {rho} < .05). For the alcoholic liver cirrhosis patients, HPI had a higher positive correlation with WHVP (r = .500; {rho} < .05) and HVPG (r = .539; {rho} < .05) than for the non-alcoholic cirrhosis patients. There was no statistical difference between the use of Miles' equation and Blomley's equation for the evaluation of portal hypertension. This preliminary study showed that HPI positively correlated with WHVP and HVPG, especially in alcoholic cirrhosis patients. Liver perfusion CT may be useful in the evaluation of portal hypertension.

  17. Active Oxygen Metabolites and Thromboxane in Phorbol Myristate Acetate Toxicity to the Isolated, Perfused Rat Lung.

    Science.gov (United States)

    Carpenter, Laurie Jean

    When administered intravenously or intratracheally to rats, rabbits and sheep, phorbol myristate acetate (PMA) produces changes in lung morphology and function are similar to those seen in humans with the adult respiratory distress syndrome (ARDS). Therefore, it is thought that information about the mechanism of ARDS development can be gained from experiments using PMA-treated animals. Currently, the mechanisms by which PMA causes pneumotoxicity are unknown. Results from other studies in rabbits and in isolated, perfused rabbit lungs suggest that PMA-induced lung injury is mediated by active oxygen species from neutrophils (PMN), whereas studies in sheep and rats suggest that PMN are not required for the toxic response. The role of PMN, active oxygen metabolites and thromboxane (TxA_2) in PMA-induced injury to isolated, perfused rat lungs (IPLs) was examined in this thesis. To determine whether PMN were required for PMA to produce toxicity to the IPL, lungs were perfused for 30 min with buffer containing various concentrations of PMA (in the presence or absence of PMN). When concentrations >=q57 ng/ml were added to medium devoid of added PMN, perfusion pressure and lung weight increased. When a concentration of PMA (14-28 ng/ml) that did not by itself cause lungs to accumulate fluid was added to the perfusion medium containing PMN (1 x 10 ^8), perfusion pressure increased, and lungs accumulated fluid. These results indicate that high concentrations of PMA produce lung injury which is independent of PMN, whereas injury induced by lower concentrations is PMN-dependent. To examine whether active oxygen species were involved in mediating lung injury induced by PMA and PMN, lungs were coperfused with the oxygen radical scavengers SOD and/or catalase. Coperfusion with either or both of these enzymes totally protected lungs against injury caused by PMN and PMA. These results suggest that active oxygen species (the hydroxyl radical in particular), mediate lung injury in

  18. Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

    International Nuclear Information System (INIS)

    Uemura, K.; Toyama, H.; Miyamoto, T.; Yoshikawa, K.; Mori, Y.

    2002-01-01

    Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images. Materials and Methods: Perfusion, ventilation and blood pool images with Tc 99m labeled radiopharmaceuticals and SPECT, tumor images with 11 C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11 C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively. Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was

  19. Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software

    Energy Technology Data Exchange (ETDEWEB)

    Ebersberger, Ullrich [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Marcus, Roy P.; Nikolaou, Konstantin; Bamberg, Fabian [University of Munich, Institute of Clinical Radiology, Munich (Germany); Schoepf, U.J.; Gray, J.C.; McQuiston, Andrew D. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Lo, Gladys G. [Hong Kong Sanatorium and Hospital, Department of Diagnostic and Interventional Radiology, Hong Kong (China); Wang, Yining [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Department of Radiology, Beijing (China); Blanke, Philipp [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University Hospital Freiburg, Department of Diagnostic Radiology, Freiburg (Germany); Geyer, Lucas L. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University of Munich, Institute of Clinical Radiology, Munich (Germany); Cho, Young Jun [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Konyang University College of Medicine, Department of Radiology, Daejeon (Korea, Republic of); Scheuering, Michael; Canstein, Christian [Siemens Healthcare, CT Division, Forchheim (Germany); Hoffmann, Ellen [Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany)

    2014-01-15

    To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 ± 11.2 and 16.5 ± 3.7 min respectively (P < 0.01). There was strong agreement between the two measures of interest (MBF, ICC = 0.91, and MBV, ICC = 0.88, both P < 0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P > 0.05. Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. (orig.)

  20. Correlation between the Quantifiable Parameters of Whole Solitary Pulmonary Nodules Perfusion Imaging Derived with Dynamic CT and Nodules Size

    Directory of Open Access Journals (Sweden)

    Shiyuan LIU

    2009-05-01

    Full Text Available Background and objective The solitary pulmonary nodules (SPNs is one of the most common findings on chest radiographs. The blood flow patterns of the biggest single SPNs level has been studied. This assessment may be only a limited sample of the entire region of interest (ROI and is unrepresentative of the SPNs as a volume. Ideally, SPNs volume perfusion should be measured. The aim of this study is to evaluate the correlation between the quantifiableparameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size. Methods Sixty-five patients with SPNs (diameter≤3 cm; 42 malignant; 12 active inflammatory; 11 benign underwent multi-location dynamic contrast material-enhanced serial CT scanning mode with stable table were performed; The mean values of valid sections were calculated, as the quantifiable parameters of volume SPNs perfusion imaging derived with16-slice spiral CT and 64-slice spiral CT. The correlation between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size were assessed by means of linear regression analysis. Results No significant correlations were found between the nodules size and each of the peak height (PHSPN (32.15 Hu±14.55 Hu,ratio of peak height of the SPN to that of the aorta (SPN-to-A ratio(13.20±6.18%, perfusion(PSPN (29.79±19.12 mLmin-1100 g-1 and mean transit time (12.95±6.53 s (r =0.081, P =0.419; r =0.089, P =0.487; r =0.167, P =0.077; r =0.023, P =0.880. Conclusion No significant correlations were found between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size.

  1. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  2. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli7938@chinaren.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com; Sun Fei [GE Healthcare (China)], E-mail: Fei.sun@med.ge.com

    2010-02-15

    Objective: To evaluate the effect of gravity and lung inflation on pulmonary perfusion heterogeneity in human lung using an arterial spin labeling (ASL) sequence called flow sensitive alternating inversion recovery (FAIR). Materials and methods: Magnetic resonance imaging of lung perfusion using arterial spin labeling sequence was performed in supine position in ten healthy volunteers on a 1.5 T whole body scanner (GE Healthcare). Five coronal slices at an interval of 3 cm from dorsal to ventral (labeled as P3, P6, P9, P12, P15, sequently) were obtained when the volunteers performed breath holding on end expiration and the relative pulmonary blood flow (rPBF) was measured. Then, another coronal perfusion-weighted image of P3 slice was obtained on end inspiration. Tagging efficiency of pulmonary parenchyma with IR ({delta}SI), rPBF and area of the P3 slice were analyzed. Results: (1) Along the direction of gravity, a gradient was visually perceived as a vertical increase in rPBF. There were significant statistic differences in rPBF between any two coronal planes except that between P12 and P15. In supine position, regression coefficients of right and left lung were -4.98 and -5.16, respectively. This means that rPBF decreased 4.98 (right) and 5.16 (left) for each centimeter above the dorsal. No statistical difference was seen between ROIs placed along iso-gravitational plane. (2) For a same slice, there were significant statistic differences in {delta}SI, rPBF and area at different respiratory phases (P < 0.05). Greater {delta}SI and more perfusion were observed on end expiration than on end inspiration. The area was larger on end inspiration than on end expiration. Conclusion: Both gravity and respiratory phase are important determinants of pulmonary perfusion heterogeneity. FAIR is sensitive to demonstrate gravity- and respiratory phase-dependent differences in lung perfusion. Positioning the patient so that the area of interest is down-gravity and asking patient

  3. Helical CT for secondary screening of lung cancer

    International Nuclear Information System (INIS)

    Mori, Kiyoshi; Onishi, Tsukasa; Tominaga, Keigo; Kishiro, Izumi; Yokoyama, Kohki.

    1995-01-01

    Helical CT was used on a trial basis for secondary screening of lung cancer, and its clinical usefulness is discussed in this report. The subjects of 157 patients with abnormal shadows on plain chest X-ray images were chosen between November 1993 and August 1994. Imaging parameters used for screening CT were as follows: 50 mA, 120 kV, a couch-top movement speed of 20 mm/s, and a beam width of 10 mm. The entire lung field was scanned during a single breath-hold. Reconstructed images were generated at 10-mm intervals by the 180deg interpolation method, and films were produced. Images of the entire lung field were made during a single breath-hold in all patients. Abnormal shadows were detected in 73 of 157 patients by screening CT. These 73 patients included 14 with lung cancer, 53 with benign lesions, one under observation, and five others. The average diameter of the tumors was 11.1 mm. The lung cancers detected all arose in the periphery, and were classified into stage I (10 patients), stage IIIA (3 patients), and stage IV with bone metastases (1 patient). Lung cancers in clinical stage I (3 patients) and stage IV (1 patient) were difficult to see on plain chest X-ray films. We conclude that screening CT is useful for early diagnosis of lung cancer because the entire lung field can be imaged during a single breath-hold. Therefore, helical CT can be expected to be useful in screening for lung cancer. (author)

  4. First Danish experience with ex vivo lung perfusion of donor lungs before transplantation

    DEFF Research Database (Denmark)

    Henriksen, Ian Sune Iversen; Møller-Sørensen, Hasse; Møller, Christian Holdfold

    2014-01-01

    INTRODUCTION: The number of lung transplantations is limited by a general lack of donor organs. Ex vivo lung perfusion (EVLP) is a novel method to optimise and evaluate marginal donor lungs prior to transplantation. We describe our experiences with EVLP in Denmark during the first year after its...... otherwise considered transplantable, but failed to meet the usual criteria due to possible contusions or because they were from donors with sepsis or unable to pass the oxygenation test. RESULTS: In the study period, seven of 33 Danish lung transplantations were made possible due to EVLP. One patient died......% improved oxygenation. The median time to extubation, time in intensive care unit and the admission period were 1, 7 and 39 days, respectively. CONCLUSION: In the first year after the introduction of EVLP in Denmark, seven pairs of donor lungs that previously would have been rejected have been transplanted...

  5. A new clinical tool for the quantification of myocardial CT perfusion imaging in patients with suspected Ischemic Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Muñoz, A.; Dux-Santoy Hurtado, L.; Rodriguez Palomares, J.L.; Piella Fenoy, G.

    2016-07-01

    In the clinical practice, the evaluation of myocardial perfusion by using Computed Tomography (CT) Imaging is usually performed visually or semi-quantitatively. The scarcity of quantitative perfusion data not always allows a proper diagnose of patients which are suspected of suffering from some diseases, such as Ischemic Heart Disease (IHD). In this work, a clinical tool for the automatic quantification of myocardial perfusion in patients with suspected IHD is proposed. Myocardial perfusion is assessed based on a combined diagnosis protocol (CT/CTP protocol) which involves the acquisition of two contrastenhanced CT images, one obtained at rest and another acquired under pharmacological stress. The clinical tool allows the automatic quantification of perfusion in different myocardial segments defined according to the 16-AHA-segmentation model of the left ventricle, by providing the mean of Hounsfield Units in those regions. Based on this analysis, the clinicians can compare the values at baseline and at hyperemia, and they can better determine hypoperfusion defects in patients with IHD. The validation of the clinical tool was performed by comparing automatic and manual perfusion measurements of 10 patients with suspected IHD who were previously assessed with Single Photon Emission Computed Tomography (SPECT) for perfusion analysis. A strong linear correlation was found between the automatic and manual results. Afterwards, perfusion defects obtained from CT/CTP protocol were compared to perfusion defects from SPECT, to assess the applicability of this clinical tool for the diagnosis of IHD. (Author)

  6. Counting the mismatches - lung ventilation/perfusion subtraction index

    International Nuclear Information System (INIS)

    Anderson, T.C.; Evans, S.G.; Larcos, G.; Farlow, D.C.

    1998-01-01

    Full text: There is potential for interobserver variability in interpretation of ventilation/perfusion (V/Q) scans. Objective quantification of V/Q mismatch could be useful. Thus, the aim of this study is to determine the validity of image subtraction in a group of 27 patients (11 men, 8 women; mean age 59.4 years [range 21-81 years])investigated by V/Q scans for suspected pulmonary emboli. A standard 6 view V/Q scan was obtained with two cobalt markers used on the anterior and posterior surfaces for image alignment. Ventilation images were normalised to the perfusion using an area of normal ventilation and perfusion. With the use of automated, and if required, manual alignment, perfusion images were subtracted from ventilation, with a median filter applied. A summed index of mismatch for each lung scan was calculated from the difference. This index was then retrospectively compared to the result reported by one of four experienced physicians. Two patients with chronic obstructive airways disease were excluded from analysis. We conclude that high probability V/Q scans can be differentiated from low probability studies using this index; further prospective investigation in a larger cohort is warranted

  7. Effect of Garlic on Perfusion Scintigraphy of Rabbit's Lungs ...

    African Journals Online (AJOL)

    Purpose: To study of the effect of garlic on rabbit's lungs, with the aid of perfusion scintigraphy, after experimentally-induced pulmonary embolism. Methods: Twelve adult rabbits were anesthetized. Prepared macroaggregated albumin- technetium 99m (99mTc-MAA) radiopharmaceutical was injected into the ear vein at a ...

  8. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    Science.gov (United States)

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  9. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  10. A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

    International Nuclear Information System (INIS)

    Rupcich, Franco; Badal, Andreu; Kyprianou, Iacovos; Schmidt, Taly Gilat

    2012-01-01

    Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360° through anthropomorphic voxelized female chest and head (0° and 30° tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI vol and multiplying by a physical CTDI vol measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30° relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are

  11. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    Energy Technology Data Exchange (ETDEWEB)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C. [University of Sheffield (United Kingdom); Ohno, Yoshiharu [Division of Functional and Diagnostic Imaging Research, Department of Radiology, KobeUniversity Graduate School of Medicine, Kobe, Hyogo (Japan); Schiebler, Mark [UW-Madison School of Medicine and Public Health, Madison, WI (United States); Wild, Jim M., E-mail: j.m.wild@sheffield.ac.uk [University of Sheffield (United Kingdom)

    2017-01-15

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  12. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    International Nuclear Information System (INIS)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C.; Ohno, Yoshiharu; Schiebler, Mark; Wild, Jim M.

    2017-01-01

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  13. Hepatic parenchymal perfusion abnormalities after pancreaticobiliary surgery. Evaluation with dynamic helical CT

    International Nuclear Information System (INIS)

    Mitsuzaki, K.; Yamashita, Y.; Ogata, I.; Nishiharu, T.; Urata, J.; Takahashi, M.

    1998-01-01

    Purpose: To evaluate perfusion abnormalities of the liver after pancreaticobiliary surgery. Material and Methods: We retrospectively evaluated 128 patients with pancreaticobiliary malignant tumors who had been examined both before and after surgery by means of helical CT of the liver. An infusion of 3 ml/s of 60% nonionic contrast material was followed by helical CT of the liver in a sequential arterial phase, portal venous phase, and equilibrium phase. Results: Of 128 patients, we followed 97. In 21 patients (22%) we found 47 lesions with perfusion abnormalities that were detected 1-33 months (mean 6.6 months) after the operation. All patients were asymptomatic. The shape of each perfusion abnormality was characterized as geographic (n=23, 47%), wedge-shaped (n=21, 45%), or round (n=3, 8%). The abnormalities were seen in the arterial phase in 46 lesions (98%), in the portal venous phase in 18 lesions (38%), and in the equilibrium phase in 1 lesion (0.2%). In all lesions, the size either decreased spontaneously, or it remained unchanged for more than one year. Conclusion: Perfusion abnormalities of the liver may occur in patients who undergo pancreaticobiliary surgery. These findings should not be confused with hypervascular metastases. (orig.)

  14. Hepatic parenchymal perfusion abnormalities after pancreaticobiliary surgery. Evaluation with dynamic helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsuzaki, K.; Yamashita, Y.; Ogata, I.; Nishiharu, T.; Urata, J.; Takahashi, M. [Kumamoto Univ., School of Medicine, Dept. of Radiology (Japan)

    1998-05-01

    Purpose: To evaluate perfusion abnormalities of the liver after pancreaticobiliary surgery. Material and Methods: We retrospectively evaluated 128 patients with pancreaticobiliary malignant tumors who had been examined both before and after surgery by means of helical CT of the liver. An infusion of 3 ml/s of 60% nonionic contrast material was followed by helical CT of the liver in a sequential arterial phase, portal venous phase, and equilibrium phase. Results: Of 128 patients, we followed 97. In 21 patients (22%) we found 47 lesions with perfusion abnormalities that were detected 1-33 months (mean 6.6 months) after the operation. All patients were asymptomatic. The shape of each perfusion abnormality was characterized as geographic (n=23, 47%), wedge-shaped (n=21, 45%), or round (n=3, 8%). The abnormalities were seen in the arterial phase in 46 lesions (98%), in the portal venous phase in 18 lesions (38%), and in the equilibrium phase in 1 lesion (0.2%). In all lesions, the size either decreased spontaneously, or it remained unchanged for more than one year. Conclusion: Perfusion abnormalities of the liver may occur in patients who undergo pancreaticobiliary surgery. These findings should not be confused with hypervascular metastases. (orig.).

  15. A porcine ex vivo lung perfusion model with maximal argon exposure to attenuate ischemia-reperfusion injury

    Directory of Open Access Journals (Sweden)

    An Martens

    2017-01-01

    Full Text Available Argon (Ar is a noble gas with known organoprotective effects in rodents and in vitro models. In a previous study we failed to find a postconditioning effect of Ar during ex vivo lung perfusion (EVLP on warm-ischemic injury in a porcine model. In this study, we further investigated a prolonged exposure to Ar to decrease cold ischemia-reperfusion injury after lung transplantation in a porcine model with EVLP assessment. Domestic pigs (n = 6/group were pre-conditioned for 6 hours with 21% O 2 and 79% N 2 (CONTR or 79% Ar (ARG. Subsequently, lungs were cold flushed and stored inflated on ice for 18 hours inflated with the same gas mixtures. Next, lungs were perfused for 4 hours on EVLP (acellular while ventilated with 12% O 2 and 88% N 2 (CONTR group or 88% Ar (ARG group. The perfusate was saturated with the same gas mixture but with the addition of CO 2 to an end-tidal CO 2 of 35-45 mmHg. The saturated perfusate was drained and lungs were perfused with whole blood for an additional 2 hours on EVLP. Evaluation at the end of EVLP did not show significant effects on physiologic parameters by prolonged exposure to Ar. Also wet-to-dry weight ratio did not improve in the ARG group. Although in other organ systems protective effects of Ar have been shown, we did not detect beneficial effects of a high concentration of Ar on cold pulmonary ischemia-reperfusion injury in a porcine lung model after prolonged exposure to Ar in this porcine model with EVLP assessment.

  16. Interleaving cerebral CT perfusion with neck CT angiography. Pt. I. Proof of concept and accuracy of cerebral perfusion values

    Energy Technology Data Exchange (ETDEWEB)

    Oei, Marcel T.H.; Meijer, Frederick J.A.; Woude, Willem-Jan van der; Smit, Ewoud J.; Ginneken, Bram van; Prokop, Mathias; Manniesing, Rashindra [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, P.O. Box 9101, Nijmegen (Netherlands)

    2017-06-15

    We present a novel One-Step-Stroke protocol for wide-detector CT scanners that interleaves cerebral CTP with volumetric neck CTA (vCTA). We evaluate whether the resulting time gap in CTP affects the accuracy of CTP values. Cerebral CTP maps were retrospectively obtained from 20 patients with suspicion of acute ischemic stroke and served as the reference standard. To simulate a 4 s gap for interleaving CTP with vCTA, we eliminated one acquisition at various time points of CTP starting from the bolus-arrival-time(BAT). Optimal timing of the vCTA was evaluated. At the time point with least errors, we evaluated elimination of a second time point (6 s gap). Mean absolute percentage errors of all perfusion values remained below 10 % in all patients when eliminating any one time point in the CTP sequence starting from the BAT. Acquiring the vCTA 2 s after reaching a threshold of 70HU resulted in the lowest errors (mean <3.0 %). Eliminating a second time point still resulted in mean errors <3.5 %. CBF/CBV showed no significant differences in perfusion values except MTT. However, the percentage errors were always below 10 % compared to the original protocol. Interleaving cerebral CTP with neck CTA is feasible with minor effects on the perfusion values. (orig.)

  17. Respiratory gated lung CT using 320-row area detector CT

    International Nuclear Information System (INIS)

    Sakamoto, Ryo; Noma, Satoshi; Higashino, Takanori

    2010-01-01

    Three hundred and twenty-row Area Detector CT (ADCT) has made it possible to scan whole lung field with prospective respiratory gated wide volume scan. We evaluated whether the respiratory gated wide volume scan enables to reduce motion induced artifacts in the lung area. Helical scan and respiratory gated wide volume scan were performed in 5 patients and 10 healthy volunteers under spontaneous breathing. Significant reduction of motion artifact and superior image quality were obtained in respiratory gated scan in comparison with helical scan. Respiratory gated wide volume scan is an unique method using ADCT, and is able to reduce motion artifacts in lung CT scans of patients unable to suspend respiration in clinical scenes. (author)

  18. A new application of Bull's eye analysis to lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yasui, Kotaro; Kohno, Yoshihiro; Akaki, Shiro; Hasegawa, Mari; Nakagawa, Tomio; Simizu, Mitsuharu; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao.

    1990-01-01

    Technetium-99m macroaggregated albumin lung perfusion scintigraphy was performed and evaluated semiquantitatively by Bull's eye analysis in 24, including 7 with central pulmonary carcinoma, 3 with hypersensitivity pneumonitis (HP), 3 with diffuse panbronchiolitis (DPB) and 11 normal subjects. First, whole lung field was divided into three regions by three concentric circles. And then radial axes were projected from the center to define 36 sectors, 10 degree each. The counts of each sector was calculated and Bull's eye image and circumferential profile curve were displayed. The patient's map was compared with the lower limit of normal (mean-2 SD), and the extent score (ES) and the severity score (SS) were calculated. The ES was 0.25±0.12 in pulmonary carcinoma (n=7), 0.08±0.07 in HP (n=3), 0.06±0.04 in DPB (n=3). The SS was 26.39±15.17 in pulmonary carcinoma, 4.75±5.57 in HP, 4.29±3.67 in DPB. In one case of central pulmonary carcinoma, segmental perfusion defect was evaluated semiquantitatively by Bull's eye image and circumferential profile curve. And in one case of HP, the change of regional pulmonary blood flow could be followed easily using extent and severity map. This new application of Bull's eye analysis to lung perfusion scintigraphy might be useful to evaluate regional pulmonary blood flow. (author)

  19. Association Between RT-Induced Changes in Lung Tissue Density and Global Lung Function

    International Nuclear Information System (INIS)

    Ma Jinli; Zhang Junan; Zhou Sumin; Hubbs, Jessica L.; Foltz, Rodney J.; Hollis, Donna R.; Light, Kim L.; Wong, Terence Z.; Kelsey, Christopher R.; Marks, Lawrence B.

    2009-01-01

    Purpose: To assess the association between radiotherapy (RT)-induced changes in computed tomography (CT)-defined lung tissue density and pulmonary function tests (PFTs). Methods and Materials: Patients undergoing incidental partial lung RT were prospectively assessed for global (PFTs) and regional (CT and single photon emission CT [SPECT]) lung function before and, serially, after RT. The percent reductions in the PFT and the average changes in lung density were compared (Pearson correlations) in the overall group and subgroups stratified according to various clinical factors. Comparisons were also made between the CT- and SPECT-based computations using the Mann-Whitney U test. Results: Between 1991 and 2004, 343 patients were enrolled in this study. Of these, 111 patients had a total of 203 concurrent post-RT evaluations of changes in lung density and PFTs available for the analyses, and 81 patients had a total of 141 concurrent post-RT SPECT images. The average increases in lung density were related to the percent reductions in the PFTs, albeit with modest correlation coefficients (range, 0.20-0.43). The analyses also indicated that the association between lung density and PFT changes is essentially equivalent to the corresponding association with SPECT-defined lung perfusion. Conclusion: We found a weak quantitative association between the degree of increase in lung density as defined by CT and the percent reduction in the PFTs.

  20. Region of interest-based versus whole-lung segmentation-based approach for MR lung perfusion quantification in 2-year-old children after congenital diaphragmatic hernia repair

    International Nuclear Information System (INIS)

    Weis, M.; Sommer, V.; Hagelstein, C.; Schoenberg, S.O.; Neff, K.W.; Zoellner, F.G.; Zahn, K.; Schaible, T.

    2016-01-01

    With a region of interest (ROI)-based approach 2-year-old children after congenital diaphragmatic hernia (CDH) show reduced MR lung perfusion values on the ipsilateral side compared to the contralateral. This study evaluates whether results can be reproduced by segmentation of whole-lung and whether there are differences between the ROI-based and whole-lung measurements. Using dynamic contrast-enhanced (DCE) MRI, pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT) were quantified in 30 children after CDH repair. Quantification results of an ROI-based (six cylindrical ROIs generated of five adjacent slices per lung-side) and a whole-lung segmentation approach were compared. In both approaches PBF and PBV were significantly reduced on the ipsilateral side (p always <0.0001). In ipsilateral lungs, PBF of the ROI-based and the whole-lung segmentation-based approach was equal (p=0.50). In contralateral lungs, the ROI-based approach significantly overestimated PBF in comparison to the whole-lung segmentation approach by approximately 9.5 % (p=0.0013). MR lung perfusion in 2-year-old children after CDH is significantly reduced ipsilaterally. In the contralateral lung, the ROI-based approach significantly overestimates perfusion, which can be explained by exclusion of the most ventral parts of the lung. Therefore whole-lung segmentation should be preferred. (orig.)

  1. Region of interest-based versus whole-lung segmentation-based approach for MR lung perfusion quantification in 2-year-old children after congenital diaphragmatic hernia repair

    Energy Technology Data Exchange (ETDEWEB)

    Weis, M.; Sommer, V.; Hagelstein, C.; Schoenberg, S.O.; Neff, K.W. [Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Zoellner, F.G. [Heidelberg University, Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Mannheim (Germany); Zahn, K. [University of Heidelberg, Department of Paediatric Surgery, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Schaible, T. [Heidelberg University, Department of Paediatrics, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany)

    2016-12-15

    With a region of interest (ROI)-based approach 2-year-old children after congenital diaphragmatic hernia (CDH) show reduced MR lung perfusion values on the ipsilateral side compared to the contralateral. This study evaluates whether results can be reproduced by segmentation of whole-lung and whether there are differences between the ROI-based and whole-lung measurements. Using dynamic contrast-enhanced (DCE) MRI, pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT) were quantified in 30 children after CDH repair. Quantification results of an ROI-based (six cylindrical ROIs generated of five adjacent slices per lung-side) and a whole-lung segmentation approach were compared. In both approaches PBF and PBV were significantly reduced on the ipsilateral side (p always <0.0001). In ipsilateral lungs, PBF of the ROI-based and the whole-lung segmentation-based approach was equal (p=0.50). In contralateral lungs, the ROI-based approach significantly overestimated PBF in comparison to the whole-lung segmentation approach by approximately 9.5 % (p=0.0013). MR lung perfusion in 2-year-old children after CDH is significantly reduced ipsilaterally. In the contralateral lung, the ROI-based approach significantly overestimates perfusion, which can be explained by exclusion of the most ventral parts of the lung. Therefore whole-lung segmentation should be preferred. (orig.)

  2. Pulmonary Perfusion Changes as Assessed by Contrast-Enhanced Dual-Energy Computed Tomography after Endoscopic Lung Volume Reduction by Coils.

    Science.gov (United States)

    Lador, Frédéric; Hachulla, Anne-Lise; Hohn, Olivia; Plojoux, Jérôme; Ronot, Maxime; Montet, Xavier; Soccal, Paola M

    2016-01-01

    Endoscopic lung volume reduction by coils (LVRC) is a recent treatment approach for severe emphysema. Furthermore, dual-energy computed tomography (DECT) now offers a combined assessment of lung morphology and pulmonary perfusion. The aim of our study was to assess the impact of LVRC on pulmonary perfusion with DECT. Seventeen patients (64.8 ± 6.7 years) underwent LVRC. DECT was performed prior to and after LVRC. For each patient, lung volumes and emphysema quantification were automatically calculated. Then, 6 regions of interest (ROIs) on the iodine perfusion map were drawn in the anterior, mid, and posterior right and left lungs at 4 defined levels. The ROI values were averaged to obtain lung perfusion as assessed by the lung's iodine concentration (CLung, μg·cm-3). The CLung values were normalized using the left atrial iodine concentration (CLA) to take into account differences between successive DECT scans. The 6-min walk distance (6MWD) improved significantly after the procedure (p = 0.0002). No lung volume changes were observed between successive DECT scans for any of the patients (p = 0.32), attesting the same suspended inspiration. After LVRC, the emphysema index was significantly reduced in the treated lung (p = 0.0014). Lung perfusion increased significantly adjacent to the treated areas (CLung/CLA from 3.4 ± 1.7 to 5.6 ± 2.2, p < 0.001) and in the ipsilateral untreated areas (from 4.1 ± 1.4 to 6.6 ± 1.7, p < 0.001), corresponding to a mean 65 and 61% increase in perfusion, respectively. No significant difference was observed in the contralateral upper and lower areas (from 4.4 ± 1.9 to 4.8 ± 2.1, p = 0.273, and from 4.9 ± 2.0 to 5.2 ± 1.7, p = 0.412, respectively). A significant correlation between increased 6MWD and increased perfusion was found (p = 0.0027, R2 = 0.3850). Quantitative analysis based on DECT acquisition revealed that LVRC results in a significant increase in perfusion in the coil-free areas adjacent to the treated ones, as

  3. Time and dose-related changes in lung perfusion after definitive radiotherapy for NSCLC

    DEFF Research Database (Denmark)

    Farr, Katherina P; Khalil, Azza A; Møller, Ditte S

    2018-01-01

    BACKGROUND AND PURPOSE: To examine radiation-induced changes in regional lung perfusion per dose level in 58 non-small-cell lung cancer (NSCLC) patients treated with intensity-modulated radiotherapy (IMRT). MATERIAL AND METHODS: NSCLC patients receiving chemo-radiotherapy (RT) of minimum 60 Gy we...

  4. Arterio-venous anastomoses in isolated, perfused rat lungs.

    Science.gov (United States)

    Conhaim, Robert L; Segal, Gilad S; Watson, Kal E

    2016-11-01

    Several studies have suggested that large-diameter (>25 μm) arterio-venous shunt pathways exist in the lungs of rats, dogs, and humans. We investigated the nature of these pathways by infusing specific-diameter fluorescent latex particles (4, 7, 15, 30, or 50 μm) into isolated, ventilated rat lungs perfused at constant pressure. All lungs received the same mass of latex (5 mg), which resulted in infused particle numbers that ranged from 1.7 × 10 7 4 μm particles to 7.5 × 10 4 50 μm particles. Particles were infused over 2 min. We used a flow cytometer to count particle appearances in venous effluent samples collected every 0.5 min for 12 min from the start of particle infusion. Cumulative percentages of infused particles that appeared in the samples averaged 3.17 ± 2.46% for 4 μm diameter particles, but ranged from 0.01% to 0.17% for larger particles. Appearances of 4 μm particles followed a rapid upslope beginning at 30 sec followed by a more gradual downslope that lasted for up to 12 min. All other particle diameters also began to appear at 30 sec, but followed highly irregular time courses. Infusion of 7 and 15 μm particles caused transient but significant perfusate flow reductions, while infusion of all other diameters caused insignificant reductions in flow. We conclude that small numbers of bypass vessels exist that can accommodate particle diameters of 7-to-50 μm. We further conclude that our 4 μm particle data are consistent with a well-developed network of serial and parallel perfusion pathways at the acinar level. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  5. The role of three dimensional functional lung imaging in radiation treatment planning: the functional dose-volume histogram

    International Nuclear Information System (INIS)

    Marks, Lawrence B.; Spencer, David P.; Sherouse, George W.; Bentel, Gunilla; Clough, Robert; Vann, Karen; Jaszczak, Ronald; Coleman, R. Edward; Prosnitz, Leonard R.

    1995-01-01

    Purpose: During thoracic irradiation (XRT), treatment fields are usually designed to minimize the volume of nontumor-containing lung included. Generally, functional heterogeneities within the lung are not considered. The three dimensional (3D) functional information provided by single photon emission computed tomography (SPECT) lung perfusion scans might be useful in designing beams that minimize incidental irradiation of functioning lung tissue. We herein review the pretreatment SPECT scans in 86 patients (56 with lung cancer) to determine which are likely to benefit from this technology. Methods and Materials: Prior to thoracic XRT, SPECT lung perfusion scans were obtained following the intravenous injection of ∼4 mCi of 99m Tc-labeled macro-aggregated albumin. The presence of areas of decreased perfusion, their location relative to the tumor, and the potential clinical usefulness of their recognition, were scored. Patients were grouped and compared (two-tailed chi-square) based on clinical factors. Conventional dose-volume histograms (DVHs) and functional DVHs (DV F Hs) are calculated based on the dose distribution throughout the computed tomography (CT)-defined lung and SPECT-defined perfused lung, respectively. Results: Among 56 lung cancer patients, decreases in perfusion were observed at the tumor, adjacent to the tumor, and separate from the tumor in 94%, 74%, and 42% of patients, respectively. Perfusion defects adjacent to the tumor were often large with centrally placed tumors. Hypoperfusion in regions separate from the tumor were statistically most common in patients with relatively poor pulmonary function and chronic obstructive pulmonary disease (COPD). Considering all SPECT defects adjacent to and separate from the tumor, corresponding CT abnormalities were seen in only ∼50% and 20% of patients, respectively, and were generally not as impressive. Following XRT, hypoperfusion at and separate from the tumor persisted, while defects adjacent to the

  6. Organotypic lung culture: A new model for studying ischemia and ex vivo perfusion in lung transplantation.

    Science.gov (United States)

    Baste, Jean-Marc; Gay, Arnaud; Smail, Hassiba; Noël, Romain; Bubenheim, Michael; Begueret, Hugues; Morin, Jean-Paul; Litzler, Pierre-Yves

    2015-01-01

    Donors after cardiac death (DCD) in lung transplantation is considered as a solution for organ shortage. However, it is characterized by warm ischemic period, which could be involved in severe Ischemia-Reperfusion lesion (IR) with early graft dysfunction. We describe a new hybrid model combining in vivo ischemia followed by in vitro reoxygenation using organ-specific culture. A hybrid model using in vivo ischemic period followed by in vitro lung slice reoxygenation was set up in rat to mimic DCD in lung transplantation with in vitro perfusion. Different markers (bioenergetics, oxidant stress assays, and histology) were measured to evaluate the viability of lung tissue after different ischemic times (I-0, I-1, I-2, I-4, I-15 hours) and reoxygenation times (R-0, R-1, R-4, R-24 hours). No differences were found in cell viability, ATP concentrations, extracellular LDH assays or histology, demonstrating extensive viability of up to 4 hours in lung tissue warm ischemia. We found oxidative stress mainly during the ischemic period with no burst at reoxygenation. Cytosolic anti-oxidant system was involved first (I-0,I-1,I-2) followed by mitochondrial anti-oxidant system for extensive ischemia (I-4). Histological features showed differences in this model of ischemia-reoxygenation between bronchial epithelium and lung parenchymal cells, with epithelium regeneration after 2 hours of warm ischemia and 24 hours of perfusion. The results of our hybrid model experiment suggest extensive lung viability of up to 4 hours ischemia. Our model could be an interesting tool to evaluate ex vivo reconditioning techniques after different in vivo lung insults.

  7. Quantitative CT characterization of pediatric lung development using routine clinical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Jill M.; Brody, Alan S.; Fleck, Robert J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Walkup, Laura L. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Pulmonary Medicine and Radiology, Cincinnati, OH (United States); Woods, Jason C. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Pulmonary Medicine and Radiology, Cincinnati, OH (United States)

    2016-12-15

    The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. We conducted a retrospective query of normal CT chest examinations in children ages 0-7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42 ± 27 months). Lung volume ranged 0.10-1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as -380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately -650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of -860 HU as age and lung volume increased. Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging. (orig.)

  8. Quantitative CT characterization of pediatric lung development using routine clinical imaging

    International Nuclear Information System (INIS)

    Stein, Jill M.; Brody, Alan S.; Fleck, Robert J.; Walkup, Laura L.; Woods, Jason C.

    2016-01-01

    The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. We conducted a retrospective query of normal CT chest examinations in children ages 0-7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42 ± 27 months). Lung volume ranged 0.10-1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as -380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately -650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of -860 HU as age and lung volume increased. Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging. (orig.)

  9. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    International Nuclear Information System (INIS)

    Bryant, Mark; Kauczor, Hans-Ulrich; Ley, Sebastian; Eberhardt, Ralf; Herth, Felix; Menezes, Ravi; Sedlaczek, Oliver; Ley-Zaporozhan, Julia

    2015-01-01

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  10. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Mark; Kauczor, Hans-Ulrich [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley, Sebastian [Chirurgische Klinik Dr. Rinecker, Department of Diagnostic and Interventional Radiology, Munich (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany); Eberhardt, Ralf; Herth, Felix [Thoraxklinik University of Heidelberg, Department of Pneumology and Critical Care Medicine, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Menezes, Ravi [University of Toronto, Medical Imaging, Toronto (Canada); Sedlaczek, Oliver [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley-Zaporozhan, Julia [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany)

    2015-01-15

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  11. Estimation of pulmonary hypertension of congenital heart diseases in children by lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Zheng Jinghao; Zhang Shantong; Zeng Jiye; Jia Hongli; Ji Zhiying; Chen Siyi

    1993-01-01

    The authors report that changes in the distribution of pulmonary perfusion caused by gravitation effect, namely, changes in the total count ratios of the right against the left lung between right and left lateral decubitus positions (rt/lt) could estimate pulmonary hypertension using lung perfusion scintigraphy with 99m Tc-labelled macroaggregated albumin. The results showed: rt/lt was inversely related to mean pulmonary arterial pressure. It is concluded that the method is simple, safe, reproducible, unaffected by cardiac structural abnormality and valuable as a noninvasive approach for the estimation of pulmonary hypertension

  12. Automated quantification of emphysema in CT studies of the lung

    International Nuclear Information System (INIS)

    Archer, D.C.; deKemp, R.A.; Coblentz, C.L.; Nahmias, C.

    1991-01-01

    Emphysema by definition is a pathologic diagnosis. Recently, in vivo quantification of emphysema from CT with point counting and with a GE 9800 CT scanner program called Density Mask has been described. These methods are laborious and time-consuming, making them unsuitable for screening. The propose of this paper is to create a screening test for emphysema. The authors developed a computer program that quantifies the amount of emphysema from standard CT-scans. The computer was programmed to recognize the lung edges on each section by identifying abrupt changes in CT numbers; grow regions within each lung to identify and separate the lungs from other structures; count regions of lung containing CT numbers measuring <-900 HU corresponding to areas of emphysema; and calculation the percentage of emphysema present from the volume of normal emphysematous lung. The programs were written in C and urn on a Sun 4/100 workstation

  13. CT Densitometry of the Lung in Healthy Nonsmokers with Normal Pulmonary Function

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Tack Sun; Chae, Eun Jin; Seo, Joon Beom; Jung, Young Ju; Oh, Yeon Mok; Lee, Sang Do [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2012-09-15

    To investigate the upper normal limit of low attenuation area in healthy nonsmokers. A total of 36 nonsmokers with normal pulmonary function test underwent a CT scan. Six thresholds (-980 --930 HU) on inspiration CT and two thresholds (-950 and -910 HU) on expiration CT were used for obtaining low attenuation area. The mean lung density was obtained on both inspiration CT and expiration CT. Descriptive statistics of low attenuation area and the mean lung density, evaluation of difference of low attenuation area and the mean lung density in both sex and age groups, analysis of the relationship between demographic information and CT parameters were performed. Upper normal limit for low attenuation area was 12.96% on inspiration CT (-950 HU) and 9.48% on expiration CT (-910 HU). Upper normal limit for the mean lung density was -837.58 HU on inspiration CT and 686.82 HU on expiration CT. Low attenuation area and the mean lung density showed no significant differences in both sex and age groups. Body mass index (BMI) was negatively correlated with low attenuation area on inspiration CT (-950 HU, r = -0.398, p = 0.016) and positively correlated with the mean lung density on inspiration CT (r 0.539, p = 0.001) and expiration CT (r = 0.432, p = 0.009). Age and body surface area were not correlated with low attenuation area or the mean lung density. Low attenuation area on CT densitometry of the lung could be found in healthy nonsmokers with normal pulmonary function, and showed negative association with BMI. Reference values, such as range and upper normal limit for low attenuation area in healthy subjects could be helpful in quantitative analysis and follow up of early emphysema, using CT densitometry of the lung.

  14. [CT-Screening for Lung Cancer - what is the Evidence?

    Science.gov (United States)

    Watermann, Iris; Reck, Martin

    2018-04-01

    In patients with lung cancer treatment opportunities and prognosis are correlated to the stage of disease with a chance for curative treatment in patients with early stage disease. Therefore, early detection of lung cancer is of paramount importance for improving the prognosis of lung cancer patients.The National Lung Screening Trial (NLST) has already shown that low-dose CT increases the number of identified early stage lung cancer patients and reduces lung cancer related mortality. Critically considered in terms of CT-screening are false-positive results, overdiagnosis and unessential invasive clarification. Preliminary results of relatively small European trials haven´t yet confirmed the results of the NLST-study.Until now Lung Cancer Screening by low dose CT-scan or other methods is neither approved nor available in Germany.To improve the efficacy of CT-Screening and to introduce early detection of lung cancer in standard practice, additional, complementing methods should be further evaluated. One option might be the supplementary analysis of biomarkers in liquid biopsies or exhaled breath condensates. In addition, defining the high-risk population is of great relevance to identify candidates who might benefit of early detection programs. © Georg Thieme Verlag KG Stuttgart · New York.

  15. TU-G-204-01: BEST IN PHYSICS (IMAGING): Dynamic CT Myocardial Perfusion Measurement and Its Comparison to Fractional Flow Reserve

    Energy Technology Data Exchange (ETDEWEB)

    Ziemer, B; Hubbard, L; Groves, E; Sadeghi, B; Javan, H; Lipinski, J; Molloi, S [University of California, Irvine, CA (United States)

    2015-06-15

    Purpose: To evaluate a first pass analysis (FPA) technique for CT perfusion measurement in a swine animal and its validation using fractional flow reserve (FFR) as a reference standard. Methods: Swine were placed under anesthesia and relevant physiologic parameters were continuously recorded. Intra-coronary adenosine was administered to induce maximum hyperemia. A pressure wire was advanced distal to the first diagonal branch of the left anterior descending (LAD) artery for FFR measurements and a balloon dilation catheter was inserted over the pressure wire into the proximal LAD to create varying levels of stenosis. Images were acquired with a 320-row wide volume CT scanner. Three main coronary perfusion beds were delineated in the myocardium using arteries extracted from CT angiography images using a minimum energy hypothesis. The integrated density in the perfusion bed was used to calculate perfusion using the FPA technique. The perfusion in the LAD bed over a range of stenosis severity was measured. The measured fractional perfusion was compared to FFR and linear regression was performed. Results: The measured fractional perfusion using the FPA technique (P-FPA) and FFR were related as P-FPA = 1.06FFR – 0.06 (r{sup 2} = 0.86). The perfusion measurements were calculated with only three to five total CT volume scans, which drastically reduces the radiation dose as compared with the existing techniques requiring 15–20 volume scans. Conclusion: The measured perfusion using the first pass analysis technique showed good correlation with FFR measurements as a reference standard. The technique for perfusion measurement can potentially make a substantial reduction in radiation dose as compared with the existing techniques.

  16. TU-G-204-01: BEST IN PHYSICS (IMAGING): Dynamic CT Myocardial Perfusion Measurement and Its Comparison to Fractional Flow Reserve

    International Nuclear Information System (INIS)

    Ziemer, B; Hubbard, L; Groves, E; Sadeghi, B; Javan, H; Lipinski, J; Molloi, S

    2015-01-01

    Purpose: To evaluate a first pass analysis (FPA) technique for CT perfusion measurement in a swine animal and its validation using fractional flow reserve (FFR) as a reference standard. Methods: Swine were placed under anesthesia and relevant physiologic parameters were continuously recorded. Intra-coronary adenosine was administered to induce maximum hyperemia. A pressure wire was advanced distal to the first diagonal branch of the left anterior descending (LAD) artery for FFR measurements and a balloon dilation catheter was inserted over the pressure wire into the proximal LAD to create varying levels of stenosis. Images were acquired with a 320-row wide volume CT scanner. Three main coronary perfusion beds were delineated in the myocardium using arteries extracted from CT angiography images using a minimum energy hypothesis. The integrated density in the perfusion bed was used to calculate perfusion using the FPA technique. The perfusion in the LAD bed over a range of stenosis severity was measured. The measured fractional perfusion was compared to FFR and linear regression was performed. Results: The measured fractional perfusion using the FPA technique (P-FPA) and FFR were related as P-FPA = 1.06FFR – 0.06 (r 2 = 0.86). The perfusion measurements were calculated with only three to five total CT volume scans, which drastically reduces the radiation dose as compared with the existing techniques requiring 15–20 volume scans. Conclusion: The measured perfusion using the first pass analysis technique showed good correlation with FFR measurements as a reference standard. The technique for perfusion measurement can potentially make a substantial reduction in radiation dose as compared with the existing techniques

  17. Pericardial Tamponade Following CT-Guided Lung Biopsy

    International Nuclear Information System (INIS)

    Mitchell, Michael J.; Montgomery, Mark; Reiter, Charles G.; Culp, William C.

    2008-01-01

    While not free from hazards, CT-guided biopsy of the lung is a safe procedure, with few major complications. Despite its safety record, however, potentially fatal complications do rarely occur. We report a case of pericardial tamponade following CT-guided lung biopsy. Rapid diagnosis and therapy allowed for complete patient recovery. Physicians who perform this procedure should be aware of the known complications and be prepared to treat them appropriately.

  18. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events

    DEFF Research Database (Denmark)

    Chen, Marcus Y.; Rochitte, Carlos E.; Arbab-Zadeh, Armin

    2017-01-01

    Purpose: To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial p...

  19. Analysis of perfusion defects by causes other than acute pulmonary thromboembolism on contrast-enhanced dual-energy CT in consecutive 537 patients

    International Nuclear Information System (INIS)

    Kim, Bo Hyun; Seo, Joon Beom; Chae, Eun Jin; Lee, Hyun Joo; Hwang, Hye Jeon; Lim, Chaehun

    2012-01-01

    Objective: To assess causes, incidence and patterns of perfusion defects (PDs) on dual-energy perfusion CT angiography (DECTA) in clinically suspected acute pulmonary thromboembolisms (PTE). Materials and methods: Consecutive 537 patients who underwent DECTA for suspicion of PTE were retrospectively reviewed. After excluding patients with possible PTE or unsatisfactory perfusion map quality, 299 patients with 1697 lobes were included. The DECTA (Somatom Definition, Siemens) was performed at 140 kV and 80 kV. Color-coded perfusion images were obtained with a lung PBV application of the workstation software (Syngo Dual Energy). The presence, incidence, three patterns of PDs (wedge-shaped, heterogeneous, and regionally homogeneous), pulmonary diseases, and the matchedness between the PD and the disease extent were studied. Results: 315 of 1697 lobes (18.6%) in 156 of 299 patients (81.3%) showed PDs. Among them, 51 (3%), 257 (15.1%), and 7 (0.4%) lobes had PDs due to vascular, nonvascular, and unidentifiable causes, respectively. Vascular causes include: pulmonary arterial (PA) hypertension (0.7%), extrinsic occlusion of PA by fibrosis (0.6%), PA hypoplasia (0.6%), vasculitis (0.5%), cancer mass compressing PA, venous occlusion, AVM, and pulmonary angiosarcoma. Most of PDs were wedge-shaped and well-matched. Nonvascular causes include: mosaic attenuation (4.1%), emphysema (3.2%), interstitial fibrosis (1.6%), bronchitis (1.4%), GGO (1.2%), cellular bronchiolitis (1%), bronchiectasis, airway obstruction, compensaroty lung hyperinflation, air trapping, cor-pulmonale, bronchopneumonia, physiologic decreased ventilation, and segmental bronchial atresia. Most of PDs showed heterogeneous pattern and were not matched. Conclusions: Various vascular and nonvascular diseases cause PDs on DECTA. Each disease shows different pattern of PD depending on pathophysiology and physiologic compensation.

  20. Studies on blood supply of liver metastasis with DSA, CT and portal vein perfusion CT during superior mesenteric arterial portography

    International Nuclear Information System (INIS)

    Li Zhigang; Shi Gaofeng; Huang Jingxiang; Li Shunzong; Liang Guoqing; Wang Hongguang; Han Pengyin; Wang Qi; Gu Tieshu

    2008-01-01

    Objective: To probe the blood supply of liver metastasis by celiac artery, proper hepatic artery DSA, portal vein perfusion CT during superior mesenteric arterial portography (PCTAP). Methods: One hundred patients with liver metastases were examined prospectively by plain CT scan, multiphase enhanced CT scan, celiac arteriography and proper hepatic arteriography. Of them, 56 patients were examined by PCTAP. All primary lesions were confirmed by operation and (or) pathology examination. In order to investigate the blood supply of metastasis lesions, the software of Photoshop was used to obtain the time-attenuation curves (TDC) of tumor center, tumor edge, portal vein and normal liver parenchyma adjacent to the tumor to calculate liver perfusion for DSA image analysis, while a deconvolution model from CT perfusion software was designed for the dual blood supply. Results: DSA findings: TDC of proper hepatic arteriography showed: the mean peak concentration (K value) in tumor centers was (67 ± 12)%, and it was (76 ± 15)% for peritumor tissue, (51 ± 10)% in normal liver parenchyma. TDC of celiac arteriogaphy showed that the contrast concentration of tumor centers and tumor edge increased fast in early stage, then maintained a slight upward plateau, in the meanwhile, the contrast concentration of normal liver parenchyma kept increasing slowly. PCTAP findings: tumors exhibited no enhancement during 30 s continued scans. Conclusion: The blood supply of liver metastasis mainly comes from hepatic artery, but barely from portal vein. (authors)

  1. A 4D digital phantom for patient-specific simulation of brain CT perfusion protocols.

    Science.gov (United States)

    van den Boom, Rieneke; Manniesing, Rashindra; Oei, Marcel T H; van der Woude, Willem-Jan; Smit, Ewoud J; Laue, Hendrik O A; van Ginneken, Bram; Prokop, Mathias

    2014-07-01

    Optimizing CT brain perfusion protocols is a challenge because of the complex interaction between image acquisition, calculation of perfusion data, and patient hemodynamics. Several digital phantoms have been developed to avoid unnecessary patient exposure or suboptimum choice of parameters. The authors expand this idea by using realistic noise patterns and measured tissue attenuation curves representing patient-specific hemodynamics. The purpose of this work is to validate that this approach can realistically simulate mean perfusion values and noise on perfusion data for individual patients. The proposed 4D digital phantom consists of three major components: (1) a definition of the spatial structure of various brain tissues within the phantom, (2) measured tissue attenuation curves, and (3) measured noise patterns. Tissue attenuation curves were measured in patient data using regions of interest in gray matter and white matter. By assigning the tissue attenuation curves to the corresponding tissue curves within the phantom, patient-specific CTP acquisitions were retrospectively simulated. Noise patterns were acquired by repeatedly scanning an anthropomorphic skull phantom at various exposure settings. The authors selected 20 consecutive patients that were scanned for suspected ischemic stroke and constructed patient-specific 4D digital phantoms using the individual patients' hemodynamics. The perfusion maps of the patient data were compared with the digital phantom data. Agreement between phantom- and patient-derived data was determined for mean perfusion values and for standard deviation in de perfusion data using intraclass correlation coefficients (ICCs) and a linear fit. ICCs ranged between 0.92 and 0.99 for mean perfusion values. ICCs for the standard deviation in perfusion maps were between 0.86 and 0.93. Linear fitting yielded slope values between 0.90 and 1.06. A patient-specific 4D digital phantom allows for realistic simulation of mean values and

  2. Comprehensive Assessment of Coronary Artery Disease by Using First-Pass Analysis Dynamic CT Perfusion: Validation in a Swine Model.

    Science.gov (United States)

    Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee

    2018-01-01

    Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (P FPA and P MSM ) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (P MICRO ), as follows: P FPA_COMBINED = 1.02 P MICRO_COMBINED + 0.11 (r = 0.96) and P MSM_COMBINED = 0.28 P MICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.

  3. Pulmonary perfusion ''without ventilation''

    International Nuclear Information System (INIS)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-01-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  4. High-resolution CT of the lungs: Anatomic-pathologic correlation

    International Nuclear Information System (INIS)

    Stein, M.G.; Webb, W.R.; Finkbeiner, W.; Gamsu, G.

    1986-01-01

    The interpretation of thin-section (1.5-mm), high-resolution CT scans of the lungs has been limited by lack of direct radiologic and pathologic correlation. The author scanned fresh inflated isolated lungs from ten healthy and five diseased subjects using thin-section, high-resolution techniques. The lungs were then fixed by inflation with endobronchial Formalin. Gough sections (1 mm thick) were obtained at the same levels as the CT scans. In healthy subjects, secondary lobules were identified by the presence of visible interlobular septa and central arterioles. In some patients with disease, septal thickening was visible. In patients with honeycombing cystic areas of destroyed lung were seen, along with areas of fibrosis. Emphysema was well evaluated. Thin-section, high-resolution CT can define lung architecture and may resolve mild changes of the interstitium

  5. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  6. CT findings of inoperable lung carcinoma

    International Nuclear Information System (INIS)

    Gay, S.B.; Black, W.C.

    1987-01-01

    CT is useful in the evaluation of patients with newly diagnosed or highly suspected lung cancer. The principal role of CT is to screen those patients with metastatic disease beyond the hili from an attempt at curative thoracotomy. While CT is regarded as very sensitive, it is not considered highly specific, and thus a surgical procedure is usually recommended for definitive diagnosis of most ''positive'' CT findings. However, the authors demonstrate a few characteristic CT findings that are highly predictive of unresectable metastatic disease. These CT findings include massive mediastinal lymphadenopathy, diffuse mediastinal infiltration, pericardial involvement, vascular encasement, and advanced chest wall invasion

  7. Three-dimensional whole-brain perfused blood volume imaging with multimodal CT for evaluation of acute ischaemic stroke

    International Nuclear Information System (INIS)

    Lu, J.; Zhang, M.; Cao, Y.; Ma, Q.; Chen, J.; Ji, X.; Li, K.

    2011-01-01

    Aim: To determine the diagnostic value of integrating three-dimensional perfused blood volume (3D PBV) with multimodal computed tomography (CT) [non-enhanced CT (NECT), CT perfusion (CTP), and CT angiography (CTA)] in acute ischaemic stroke. Materials and methods: NECT, CTP, and CTA were performed in 25 acute ischaemic stroke patients. The ischaemia detection rate of 3D PBV was compared with the results of baseline NECT and CTP. The correlation of ischaemic lesion volume between 3D PBV, CTP images, and follow-up NECT were analysed. Results: NECT demonstrated ischaemic signs in 12 of 25 patients with proven infarction. CTP maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and time to peak (TTP) all demonstrated perfusion deficits in 21 of 25 patients. However, 3D PBV demonstrated perfusion deficits in all of the 25 patients. Among the 25 patients, a strong correlation was found between PBV and the follow-up NECT infarct (r = 0.858). The correlation between CTP and the follow-up NECT infarct as following: CBF (r = 0.718), CBV (r = 0.785), and TTP (r = 0.569). In 14 thrombolytic patients, strong correlation was found between the ischaemic volume on 3D PBV and follow-up NECT (r = 0.798). Conclusion: In acute stroke patients, the combination of 3D PBV and multimodal CT (NECT, CTP, and CTA) can improve the detection rate of ischaemia and enable assessment of the full extent of ischaemia, which correlates well with follow-up NECT.

  8. CT image construction of a totally deflated lung using deformable model extrapolation

    International Nuclear Information System (INIS)

    Sadeghi Naini, Ali; Pierce, Greg; Lee, Ting-Yim

    2011-01-01

    Purpose: A novel technique is proposed to construct CT image of a totally deflated lung from a free-breathing 4D-CT image sequence acquired preoperatively. Such a constructed CT image is very useful in performing tumor ablative procedures such as lung brachytherapy. Tumor ablative procedures are frequently performed while the lung is totally deflated. Deflating the lung during such procedures renders preoperative images ineffective for targeting the tumor. Furthermore, the problem cannot be solved using intraoperative ultrasound (U.S.) images because U.S. images are very sensitive to small residual amount of air remaining in the deflated lung. One possible solution to address these issues is to register high quality preoperative CT images of the deflated lung with their corresponding low quality intraoperative U.S. images. However, given that such preoperative images correspond to an inflated lung, such CT images need to be processed to construct CT images pertaining to the lung's deflated state. Methods: To obtain the CT images of deflated lung, we present a novel image construction technique using extrapolated deformable registration to predict the deformation the lung undergoes during full deflation. The proposed construction technique involves estimating the lung's air volume in each preoperative image automatically in order to track the respiration phase of each 4D-CT image throughout a respiratory cycle; i.e., the technique does not need any external marker to form a respiratory signal in the process of curve fitting and extrapolation. The extrapolated deformation field is then applied on a preoperative reference image in order to construct the totally deflated lung's CT image. The technique was evaluated experimentally using ex vivo porcine lung. Results: The ex vivo lung experiments led to very encouraging results. In comparison with the CT image of the deflated lung we acquired for the purpose of validation, the constructed CT image was very similar. The

  9. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    International Nuclear Information System (INIS)

    San Millan Ruiz, Diego; Murphy, Kieran; Gailloud, Philippe

    2010-01-01

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  10. Lung cancer in patients with idiopathic pulmonary fibrosis: frequency and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong; Im, Jung Gi; Ahn, Joong Mo; Yeon, Kyung Mo [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1994-12-15

    The incidence of lung cancer in patients with idiopathic pulmonary fibrosis(lPF) is higher than that of general population. To evaluate the frequency and CT findings of lung cancer associated with idiopathic pulmonary fibrosis, we analyzed 19 patients with lung cancer associated with idiopathic pulmonary fibrosis. We analyzed retrospectively 19 patients with histologically confirmed lung cancer out of 208 patients diagnosed as IPF either by CT and clinical findings(n=188) or histologically(n=20). All 19 patients were male, aged 40-85 years (mean 66 years). Scanning techniques were conventional CT in 12 patients, HRCT in 1 patient and both conventional CT and HRCT in 6 patients. We analyzed the CT patterns of lung cancer and IPF, locations of the tumor and histologic types of lung cancer. The incidence of lung cancer in patients with idiopathic pulmonary fibrosis was 9.1%(19/208). In 11 of 19 patients, CT findings of lung cancer were ill-defined consolidation-like mass. Lung cancer was located mainly in lower lobes(right lower lobe; 10/19, left lower lobe; 5/19) and at the periphery(12/19). Histologically, squamous cell carcinoma was the most common cell type (11/19). The incidence of lung cancer in patients with idiopathic pulmonary fibrosis was much higher than that of general population. Typical CT findings of lung cancer were predominantly ill-defined consolidation like mass at the peripheral lung portion which is the location where the most advanced fibrosis occur.

  11. Lung cancer in patients with idiopathic pulmonary fibrosis: frequency and CT findings

    International Nuclear Information System (INIS)

    Lee, Hak Jong; Im, Jung Gi; Ahn, Joong Mo; Yeon, Kyung Mo

    1994-01-01

    The incidence of lung cancer in patients with idiopathic pulmonary fibrosis(lPF) is higher than that of general population. To evaluate the frequency and CT findings of lung cancer associated with idiopathic pulmonary fibrosis, we analyzed 19 patients with lung cancer associated with idiopathic pulmonary fibrosis. We analyzed retrospectively 19 patients with histologically confirmed lung cancer out of 208 patients diagnosed as IPF either by CT and clinical findings(n=188) or histologically(n=20). All 19 patients were male, aged 40-85 years (mean 66 years). Scanning techniques were conventional CT in 12 patients, HRCT in 1 patient and both conventional CT and HRCT in 6 patients. We analyzed the CT patterns of lung cancer and IPF, locations of the tumor and histologic types of lung cancer. The incidence of lung cancer in patients with idiopathic pulmonary fibrosis was 9.1%(19/208). In 11 of 19 patients, CT findings of lung cancer were ill-defined consolidation-like mass. Lung cancer was located mainly in lower lobes(right lower lobe; 10/19, left lower lobe; 5/19) and at the periphery(12/19). Histologically, squamous cell carcinoma was the most common cell type (11/19). The incidence of lung cancer in patients with idiopathic pulmonary fibrosis was much higher than that of general population. Typical CT findings of lung cancer were predominantly ill-defined consolidation like mass at the peripheral lung portion which is the location where the most advanced fibrosis occur

  12. [Lung scintigraphy].

    Science.gov (United States)

    Schümichen, Carl; Schmidt, Matthias; Krause, Thomas

    2018-06-01

    The S1 guideline for lung scintigraphy has been updated and extended in order to emphasize the advantages oft the method in detecting acute pulmonary embolism (PE) in the periphery oft the lung (subsegmental PE), in underlying subacute and chronic pulmonary disorders, as well as in detecting chronic LE (CTEPH). Method of choice is ventilation / perfusion (V/P) SPECT or V/P SPECT/CT with even higher specificity. Because of its high sensitivity, a threshold (V/P mismatch in at least one segment or two subsegments) is introduced to avoid overtreatment. In case of a change in the therapeutic approach (observation only instead of anticoaculation) the threshold can be omitted. New data concerning the clinical and therapeutical impact of subsegmental PE are included, the chapters open questions have been extented. Other indications for V/P SPECT (secondary diagnoses, abnormalities in pulmonary perfusion, prediction of postoperative lung function) are presented with new data. Schattauer GmbH.

  13. CT Perfusion evaluation of gastric cancer. Correlation with histologic type

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Ho; Joo, Ijin [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Kim, Se Hyung [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Han, Joon Koo [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2018-02-15

    To prospectively evaluate if the perfusion parameters of gastric cancer can provide information on histologic subtypes of gastric cancer. We performed preoperative perfusion CT (PCT) and curative gastrectomy in 46 patients. PCT data were analysed using a dedicated software program. Perfusion parameters were obtained by two independent radiologists and were compared according to histologic type using Kruskal-Wallis, Mann-Whitney U test and receiver operating characteristic analysis. To assess inter-reader agreement, we used intraclass correlation coefficient (ICC). Inter-reader agreement for perfusion parameters was moderate to substantial (ICC = 0.585-0.678). Permeability surface value of poorly cohesive carcinoma (PCC) was significantly higher than other histologic types (47.3 ml/100 g/min in PCC vs 26.5 ml/100 g/min in non-PCC, P < 0.001). Mean transit time (MTT) of PCC was also significantly longer than non-PCC (13.0 s in PCC vs 10.3 s in non-PCC, P = 0.032). The area under the curve to predict PCC was 0.891 (P < 0.001) for permeability surface and 0.697 (P = 0.015) for MTT. Obtaining perfusion parameters from PCT was feasible in gastric cancer patients and can aid in the preoperative imaging diagnosis of PCC-type gastric cancer as the permeability surface and MTT value of PCC type gastric cancer were significantly higher than those of non-PCC. (orig.)

  14. CT Perfusion evaluation of gastric cancer. Correlation with histologic type

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Joo, Ijin; Kim, Se Hyung; Han, Joon Koo

    2018-01-01

    To prospectively evaluate if the perfusion parameters of gastric cancer can provide information on histologic subtypes of gastric cancer. We performed preoperative perfusion CT (PCT) and curative gastrectomy in 46 patients. PCT data were analysed using a dedicated software program. Perfusion parameters were obtained by two independent radiologists and were compared according to histologic type using Kruskal-Wallis, Mann-Whitney U test and receiver operating characteristic analysis. To assess inter-reader agreement, we used intraclass correlation coefficient (ICC). Inter-reader agreement for perfusion parameters was moderate to substantial (ICC = 0.585-0.678). Permeability surface value of poorly cohesive carcinoma (PCC) was significantly higher than other histologic types (47.3 ml/100 g/min in PCC vs 26.5 ml/100 g/min in non-PCC, P < 0.001). Mean transit time (MTT) of PCC was also significantly longer than non-PCC (13.0 s in PCC vs 10.3 s in non-PCC, P = 0.032). The area under the curve to predict PCC was 0.891 (P < 0.001) for permeability surface and 0.697 (P = 0.015) for MTT. Obtaining perfusion parameters from PCT was feasible in gastric cancer patients and can aid in the preoperative imaging diagnosis of PCC-type gastric cancer as the permeability surface and MTT value of PCC type gastric cancer were significantly higher than those of non-PCC. (orig.)

  15. Value of PET-CT and PET-CT combined with lung VCAR software in the diagnosis of hilar area lymph nodes of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Yu Lijuan; Li Yingci; Wang Wenzhi; Wang Xin; Lu Pei'ou; Tian Mohan

    2012-01-01

    Objective: To explore the diagnostic value of PET-CT and PET-CT combined with lung volume computed assisted reading (Lung VCAR) software in hilar area lymph nodes. Methods: Preoperative whole body PET-CT imaging was performed in 49 patients who were highly suspicious of non-small cell lung cancer. PET-CT images of the hilar area lymph nodes and the PET-CT images of the hilar area lymph nodes from Lung VCAR software were evaluated by two experienced doctors, and then compared with the pathological diagnosis. Results: There was no significant difference between the CT values of benign and malignant lymph nodes (t=-1.40, P>0.05). But a significant difference was existed between the benign and malignant hilar lymph nodes with the density visual analysis, the lymph short diameter and the maximum of standardized uptake value (SUV max ) (χ 2 =30.37, 27.40, 20.06, all P<0.05). The sensibility,specificity and accuracy of PET-CT in diagnosis of the hilar area lymph nodes were 76.5%, 90.7%, 88.3% respectively, and the accuracy of the diagnosis was significantly higher than that of CT and PET alone (χ 2 =15.27, P<0.05) using the lymph short diameter ≥1 cm of CT, the density of lymph node is equal to (slightly lower than) the same layer vascular density and the lymph node SUV max ≥2.5 of PET as the diagnostic criteria. One hundred and three hilar area lymph nodes were diagnosed by PET-CT and four nodes were not hilar lymph nodes proved by the Lung VCAR software (3 hilar vascular uptake,1 bronchial cartilage). Conclusion: The methods of PET-CT lymph visual density analysis plus lymph node diameter and SUV max had a high diagnostic accuracy of non-small cell lung hilar lymph. For the PET-CT,the pulmonary vascular uptake was the main cause affecting the discrimination of hilar lymph nodes,while Lung VCAR software was helpful to diagnosis. (authors)

  16. Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model

    International Nuclear Information System (INIS)

    Sun Changjin; Li Chao; Lv Haibo

    2014-01-01

    The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3–127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2–53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7–124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2–62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14–47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice. (author)

  17. Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model.

    Science.gov (United States)

    Sun, Chang-Jin; Li, Chao; Lv, Hai-Bo; Zhao, Cong; Yu, Jin-Ming; Wang, Guang-Hui; Luo, Yun-Xiu; Li, Yan; Xiao, Mingyong; Yin, Jun; Lang, Jin-Yi

    2014-01-01

    The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3-127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2-53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7-124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2-62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14-47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice.

  18. Diagnostic accuracy of static CT perfusion for the detection of myocardial ischemia

    DEFF Research Database (Denmark)

    Sørgaard, Mathias Holm; Kofoed, Klaus Fuglsang; Linde, Jesper James

    2016-01-01

    : Systematic literature review and meta-analysis of studies examining the diagnostic accuracy of static CTP imaging alone or combined with coronary CT angiography (CTA) in comparison to single photon emission computed tomography (SPECT), magnetic resonance perfusion (MRP), and/or invasive coronary angiography...

  19. Assessment of perfusion pattern and extent of perfusion defect on dual-energy CT angiography: Correlation between the causes of pulmonary hypertension and vascular parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young [Dept. of Radiology, Chonbuk National University Medical School and Hospital, Research Institute of Clinical Medicine, Jeonju (Korea, Republic of); Seo, Joon Beom; Oh, Sang Young; Lee, Choong Wook; Lee, Sang Min [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Hwang, Hye Jeon [Dept. of Radiology, Hallym University College of Medicine, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Lee, Young Kyung [Dept. of Radiology, Seoul Medical Center, Seoul (Korea, Republic of)

    2014-04-15

    To assess perfusion patterns on a dual-energy pulmonary CT angiography (DECTA) of pulmonary hypertension (PHT) with variable causes and to assess whether the extent of perfusion defect can be used in the severity assessment of PHT. Between March 2007 and February 2011, DECTA scans of 62 consecutive patients (24 men, 38 women; mean age, 58.5 ± 17.3 [standard deviation] years; range, 19-87 years) with PHT were retrospectively included with following inclusion criteria; 1) absence of acute pulmonary thromboembolism, 2) maximal velocity of tricuspid regurgitation jet (TR Vmax) above 3 m/s on echocardiography performed within one week of the DECTA study. Perfusion patterns of iodine map were divided into normal (NL), diffuse heterogeneously decreased (DH), multifocal geographic and multiple peripheral wedging patterns. The extent of perfusion defects (PD), the diameter of main pulmonary artery (MPA) and the ratio of ascending aorta diameter/MPA (aortopulmonary ratio, APR) were measured. Pearson correlation analysis was performed between TR Vmax on echocardiography and CT imaging parameters. Common perfusion patterns of primary PHT were DH (n = 15) and NL (n = 12). The perfusion patterns of secondary PHT were variable. On the correlation analysis, in primary PHT, TR Vmax significantly correlated with PD, MPA and APR (r = 0.52, r = 0.40, r = -0.50, respectively, all p < 0.05). In secondary PHT, TR Vmax significantly correlated with PD and MPA (r = 0.38, r = 0.53, respectively, all p < 0.05). Different perfusion patterns are observed on DECTA of PHT according to the causes. PD and MPA are significantly correlated with the TR Vmax.

  20. Assessment of perfusion pattern and extent of perfusion defect on dual-energy CT angiography: Correlation between the causes of pulmonary hypertension and vascular parameters

    International Nuclear Information System (INIS)

    Kim, Eun Young; Seo, Joon Beom; Oh, Sang Young; Lee, Choong Wook; Lee, Sang Min; Hwang, Hye Jeon; Lee, Young Kyung

    2014-01-01

    To assess perfusion patterns on a dual-energy pulmonary CT angiography (DECTA) of pulmonary hypertension (PHT) with variable causes and to assess whether the extent of perfusion defect can be used in the severity assessment of PHT. Between March 2007 and February 2011, DECTA scans of 62 consecutive patients (24 men, 38 women; mean age, 58.5 ± 17.3 [standard deviation] years; range, 19-87 years) with PHT were retrospectively included with following inclusion criteria; 1) absence of acute pulmonary thromboembolism, 2) maximal velocity of tricuspid regurgitation jet (TR Vmax) above 3 m/s on echocardiography performed within one week of the DECTA study. Perfusion patterns of iodine map were divided into normal (NL), diffuse heterogeneously decreased (DH), multifocal geographic and multiple peripheral wedging patterns. The extent of perfusion defects (PD), the diameter of main pulmonary artery (MPA) and the ratio of ascending aorta diameter/MPA (aortopulmonary ratio, APR) were measured. Pearson correlation analysis was performed between TR Vmax on echocardiography and CT imaging parameters. Common perfusion patterns of primary PHT were DH (n = 15) and NL (n = 12). The perfusion patterns of secondary PHT were variable. On the correlation analysis, in primary PHT, TR Vmax significantly correlated with PD, MPA and APR (r = 0.52, r = 0.40, r = -0.50, respectively, all p < 0.05). In secondary PHT, TR Vmax significantly correlated with PD and MPA (r = 0.38, r = 0.53, respectively, all p < 0.05). Different perfusion patterns are observed on DECTA of PHT according to the causes. PD and MPA are significantly correlated with the TR Vmax.

  1. SPECT/CT and pulmonary embolism

    DEFF Research Database (Denmark)

    Mortensen, Jann; Borgwardt, Henrik Gutte

    2014-01-01

    the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume......Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar...

  2. CT perfusion-guided patient selection for endovascular recanalization in acute ischemic stroke: a multicenter study.

    Science.gov (United States)

    Turk, Aquilla S; Magarick, Jordan Asher; Frei, Don; Fargen, Kyle Michael; Chaudry, Imran; Holmstedt, Christine A; Nicholas, Joyce; Mocco, J; Turner, Raymond D; Huddle, Daniel; Loy, David; Bellon, Richard; Dooley, Gwendolyn; Adams, Robert; Whaley, Michelle; Fanale, Chris; Jauch, Edward

    2013-11-01

    The treatment of acute ischemic stroke is traditionally centered on time criteria, although recent evidence suggests that physiologic neuroimaging may be useful. In a multicenter study we evaluated the use of CT perfusion, regardless of time from symptom onset, in patients selected for intra-arterial treatment of ischemic stroke. Three medical centers retrospectively assessed stroke patients with a National Institute of Health Stroke Scale of ≥ 8, regardless of time from symptom onset. CT perfusion maps were qualitatively assessed. Patients with defined salvageable penumbra underwent intra-arterial revascularization of their occlusion. Functional outcome using the modified Rankin Score (mRS) was recorded. Two hundred and forty-seven patients were selected to undergo intra-arterial treatment based on CT perfusion imaging. The median time from symptom onset to procedure was 6 h. Patients were divided into two groups for analysis: ≤ 8 h and >8 h from symptom onset to endovascular procedure. We found no difference in functional outcome between the two groups (42.8% and 41.9% achieved 90-day mRS ≤ 2, respectively (p=1.0), and 54.9% vs 55.4% (p=1.0) achieved 90-day mRS ≤ 3, respectively). Overall, 48 patients (19.4%) had hemorrhages, of which 20 (8.0%) were symptomatic, with no difference between the groups (p=1.0). In a multicenter study, we demonstrated similar rates of good functional outcome and intracranial hemorrhage in patients with ischemic stroke when endovascular treatment was performed based on CT perfusion selection rather than time-guided selection. Our findings suggest that physiologic imaging-guided patient selection rather than time for endovascular reperfusion in ischemic stroke may be effective and safe.

  3. How to choose PET-CT or CT in the diagnosis and staging of lung cancer. Practical experience in China

    International Nuclear Information System (INIS)

    Jiang, T.; Tao, X.; Liu, H.; Liu, S.; Zheng, X.

    2010-01-01

    How to use CT and PET-CT rationally to raise diagnosis, staging and prognostic assessment of lung cancer to a higher level at the best cost-effect ratio is a subject that Chinese clinicians and radiologists should face conscientiously. We review the rational application of CT and PET-CT in four aspects of lung cancer, including screening and detection, morphologic evaluation, haemodynamic or metabolic feature evaluation, and follow-up, staging and prognostic evaluation. As PET-CT is only available in class III-A hospitals today, CT is the most popular equipment in China. PET-CT is more valuable only in cases where CT presentation of lung cancer is atypical or difficult to determine, or in cases where the diagnosis of lung cancer has been initially confirmed, for which clinical staging and decision concerning on therapeutic regimens are needed. We also recommend the current strategies of CT and PET-CT managing of SPN in China. (orig.)

  4. Evaluation of pN factors in patients with primary lung cancer by using perfusion, inhalation and ventilation studies

    International Nuclear Information System (INIS)

    Tamai, Toyosato; Tanabe, Masatada; Satoh, Katashi

    1987-01-01

    The interpretation of scintigraphic patterns and the role of pathophysiological mechanisms in patients with primary lung cancer were investigated. To determine the relative roles of perfusion, inhalation and ventilation scintigraphy, the relationship between the count ratio of the affected side to the healthy side and the post-surgical histological lymph nodes factors were observed in this study. These scintigraphic count ratio's in patients with primary lung cancer did not reflect the pN factors except in the perfusion study in patients with hilar primary lung cancer. (author)

  5. Applications and interpretation of krypton 81m ventilation/technetium 99m macroaggregate perfusion lung scanning in childhood

    Science.gov (United States)

    Davies, Hugh Trevor Frimston

    Radionuclide ventilation perfusion lung scans now play an important part in the investigation of paediatric lung disease, providing a safe, noninvasive assessment of regional lung function in children with suspected pulmonary disease. In paediatric practice the most suitable radionuclides are Krypton 81m (Kr81m) and Technetium 99m (Tc99m), which are jointly used in the Kr81m ventilation/Tc99m macroaggregate perfusion lung scan (V/Q lung scan). The Kr81m ventilation scan involves a low radiation dose, requires little or no subject cooperation and because of the very short half life of Kr81m (13 seconds) the steady state image acquired during continuous inhalation of the radionuclide is considered to reflect regional distribution of ventilation. It is now the most important noninvasive method available for the investigation of the regional abnormalities of ventilation characteristic of many congenital and acquired paediatric respiratory diseases, such as diaphragmatic hernia, pulmonary sequestration, bronchopulmonary dysplasia, foreign body inhalation and bronchiectasis. It improves diagnostic accuracy, aids clinical decision making and is used to monitor the progress of disease and response to therapy. Theoretical analysis of the steady state Kr81m ventilation image suggests that it may only reflect regional ventilation when specific ventilation (ventilation per unit volume of lung) is within or below the normal adult range (1-3 L/L/min). At higher values such as those seen in neonates and infants (8-15 L/L/min) Kr81m activity may reflect regional lung volume rather than ventilation, a conclusion supported by the studies of Ciofetta et al. There is some controversy on this issue as animal studies have demonstrated that the Kr81m image reflects ventilation over a much wider range of specific ventilation (up to 13 L/L/min). A clinical study of sick infants and very young children is in agreement with this animal work and suggests that the steady state Kr81m image

  6. CT diagnosis of the primary lung cancer and usefulness of biopsy under CT

    International Nuclear Information System (INIS)

    Fujisawa, Hidefumi; Kushihashi, Tamio

    2011-01-01

    CT especially plays an important role in imaging diagnosis of lung cancer (LC) which gives quite multiple CT findings and this paper describes details to be noted for CT findings of individual lung lesion and cancer according to 5 classes below, together with usefulness of CT-guided biopsy and positron emission tomography (PET) usage. Explained are as follows: Important points in histopathology and CT findings from adenomatous hyperplasia (AH) to atypical AH (pre-invasive lesion); Differential CT diagnosis of benignity or malignancy of pulmonary nodes and tumors; Typical CT findings of LC of peripheral type of invasive or exclusive proliferative type, and pulmonary hillar type; Atypical CT findings of LC/having atypical inner structure such as presenting atypical calcification and atypical cavity/having atypical morphology such as presenting pneumonia-like finding, exhibiting regular or linear edge, and existing at atypical region like extrapleural lumen /having atypical progression rate such as showing rapid or slow doubling time of the volume and shrinking tentatively during the progress/of juvenile LC/and generated from background lung diseases such as interstitial pneumonia, tuberculosis, pneumoconiosis like asbestosis, pneumosilicosis, and pulmonary emphysema and bulla; and Regional ground glass opacity. As well, authors mention about the usefulness of CT-guided needle biopsy of the pulmonary lesion which enables to take the nodal specimen as small as <10 mm. Most frequent complication of the biopsy is pneumothorax (10-50%). How to use PET for LC examination is also commented with its usability and limitation. (T.T.)

  7. CT evaluation of complications of cryoablation treatment in lung cancer

    International Nuclear Information System (INIS)

    Zhu Caiqiao; Chen Yao; Zhang Zhitian; Su Jinzhan; Huang Zhen; Bao Kaikai

    2011-01-01

    Objective: To assess the complications of percutaneous targeted Argon-Helium cryoablation treatment in patients with lung cancer on CT. Methods: Ten patients with unresectable lung cancer were treated by cryotherapy under CT guidance with Argon-Helium cryoablation system. Dynamic contrast-enhanced CT was performed to assess changes before and after treatment, complications and treatment response. Results: Ice ball coverage immediately after surgery was satisfactory in all patients. There were a few complications including worsening hoarseness (1), small pneumothorax (1), and small amount of bleeding at the site of probe puncture (1). Conclusion: Percutaneous targeted Argon-Helium cryoablation guided by CT is an effective treatment for lung cancer without severe complications. (authors)

  8. Quantitative measurement of lung density with x-ray CT and positron CT, (2)

    International Nuclear Information System (INIS)

    Ito, Kengo; Ito, Masatoshi; Kubota, Kazuo

    1985-01-01

    Lung density was quantitatively measured on six diseased patients with X-ray CT (XCT) and Positron CT(PCT). The findings are as follows: In the silicosis, extravascular lung density was found to be remarkably increased compared to normals (0.29gcm -3 ), but blood volume was in normal range. In the post-irradiated lung cancers, extravascular lung density increased in the irradiated sites compared to the non-irradiated opposite sites, and blood volume varied in each case. In a patient with chronic heart failure, blood volume decreased (0.11mlcm -3 ) with increased extravascular lung density (0.23gcm -3 ). In the chronic obstructive pulmonary disease, both extravascular lung density and blood volume decreased (0.11gcm -3 and 0.10mlcm -3 respectively). Lung density measured with XCT was constantly lower than that with PCT in all cases. But changes in the values of lung density measured, correlated well with each other. In conclusion, the method presented here may clarify the etiology of the diffuse pulmonary diseases, and be used to differentiate and grade the diseases. (author)

  9. The dream of a one-stop-shop : Meta-analysis on myocardial perfusion CT

    NARCIS (Netherlands)

    Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A. M.; Schoepf, U. Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn

    2015-01-01

    Purpose: To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography

  10. Chronic thromboembolic pulmonary hypertension (CTEPH). Potential role of multidetector-row CT (MD-CT) and MR imaging in the diagnosis and differential diagnosis of the disease

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, G.; Brueggemann, K.; Bostel, T.; Dueber, C.; Kreitner, K.F. [Universitaetsmedizin Mainz (Germany). Dept. of Radiology; Mayer, E. [Kerckhoff Hospital, Bad Nauheim (Germany). Dept. of Thoracic Surgery

    2014-08-15

    Chronic thromboembolic pulmonary hypertension (CTEPH) can be defined as pulmonary hypertension (resting mean pulmonary arterial pressure of 25 mm Hg or more determined at right heart catheterization) with persistent pulmonary perfusion defects. It is a rare, but underdiagnosed disease with estimated incidences ranging from 0.5% to 3.8% of patients after an acute pulmonary embolism (PE), and in up to 10% of those with a history of recurrent PE. CTEPH is the only form of pulmonary hypertension that can be surgically treated leading to normalization of pulmonary hemodynamics and exercise capacity in the vast majority of patients. The challenges for imaging in patients with suspected CTEPH are fourfold: the imaging modality should have a high diagnostic accuracy with regard to the presence of CTEPH and allow for differential diagnosis. It should enable detection of patients suitable for PEA with great certainty, and allow for quantification of PH by measuring pulmonary hemodynamics (mPAP and PVR), and finally, it can be used for therapy monitoring. This overview tries to elucidate the potential role of ECG-gated multidetector CT pulmonary angiography (MD-CTPA) and MR imaging, and summarizes the most important results that have been achieved so far. Generally speaking, ECG-gated MD-CTPA is superior to MR in the assessment of parenchymal and vascular pathologies of the lung, and allows for the assessment of cardiac structures. The implementation of iodine maps as a surrogate for lung perfusion enables functional assessment of lung perfusion by CT. MR imaging is the reference standard for the assessment of right heart function and lung perfusion, the latter delineating typical wedge-shaped perfusion defects in patients with CTEPH. New developments show that with MR techniques, an estimation of hemodynamic parameters like mean pulmonary arterial pressure and pulmonary vascular resistance will be possible. CT and MR imaging should be considered as complementary

  11. Characterization of tumor heterogeneity using dynamic contrast enhanced CT and FDG-PET in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Elmpt, Wouter van; Das, Marco; Hüllner, Martin; Sharifi, Hoda; Zegers, Catharina M.L.; Reymen, Bart; Lambin, Philippe; Wildberger, Joachim E.; Troost, Esther G.C.; Veit-Haibach, Patrick; De Ruysscher, Dirk

    2013-01-01

    Purpose: Dynamic contrast-enhanced CT (DCE-CT) quantifies vasculature properties of tumors, whereas static FDG-PET/CT defines metabolic activity. Both imaging modalities are capable of showing intra-tumor heterogeneity. We investigated differences in vasculature properties within primary non-small cell lung cancer (NSCLC) tumors measured by DCE-CT and metabolic activity from FDG-PET/CT. Methods: Thirty three NSCLC patients were analyzed prior to treatment. FDG-PET/CT and DCE-CT were co-registered. The tumor was delineated and metabolic activity was segmented on the FDG-PET/CT in two regions: low (<50% maximum SUV) and high (⩾50% maximum SUV) metabolic uptake. Blood flow, blood volume and permeability were calculated using a maximum slope, deconvolution algorithm and a Patlak model. Correlations were assessed between perfusion parameters for the regions of interest. Results: DCE-CT provided additional information on vasculature and tumor heterogeneity that was not correlated to metabolic tumor activity. There was no significant difference between low and high metabolic active regions for any of the DCE-CT parameters. Furthermore, only moderate correlations between maximum SUV and DCE-CT parameters were observed. Conclusions: No direct correlation was observed between FDG-uptake and parameters extracted from DCE-CT. DCE-CT may provide complementary information to the characterization of primary NSCLC tumors over FDG-PET/CT imaging

  12. Comparison between CT perfusion and Tc-99m ECD SPECT in the assessment of cerebrovascular reserve: a case study

    International Nuclear Information System (INIS)

    Crouch, J.; Wood, C.; Campbell, A.; McCarthy, M.; Dunne, M.; Bynevelt, M.; Lenzo, N.

    2003-01-01

    Full text: Brain perfusion is sensitively assessed by cerebral SPECT imaging utilising perfusion agents such as Tc-99m HMPAO and Tc-99m ethyl cysteinate dimer (ECD). Positron emission tomography can accurately assess and quantify brain perfusion and MRI can also be used for perfusion assessment. Both MRI and PET however are currently limited by cost and availability. A new technique utilising CT with contrast has been developed to assess and quantitate cerebral perfusion. The technique utilises arterial input information and deconvolution analysis to develop quantifiable measures of perfusion and contrast transit. The technique has been validated for acute stroke assessment and is being assessed for other possible applications. We present a case study comparison of this technique with cerebral SPECT perfusion using Tc-99m ECD in the assessment of cerebrovasular reserve. In each case, the CT and SPECT studies were performed pre- and post-acetazolamide and the SPECT study was statistically compared with a normal database utilising an automated brain perfusion statistical analysis package (NeurostatT). We discuss the correlation found between techniques, their strengths, weaknesses and possible future roles. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  13. Detection of reactive oxygen species in isolated, perfused lungs by electron spin resonance spectroscopy

    Directory of Open Access Journals (Sweden)

    Schudt Christian

    2005-07-01

    Full Text Available Abstract Background The sources and measurement of reactive oxygen species (ROS in intact organs are largely unresolved. This may be related to methodological problems associated with the techniques currently employed for ROS detection. Electron spin resonance (ESR with spin trapping is a specific method for ROS detection, and may address some these technical problems. Methods We have established a protocol for the measurement of intravascular ROS release from isolated buffer-perfused and ventilated rabbit and mouse lungs, combining lung perfusion with the spin probe l-hydroxy-3-carboxy-2,2,5,5-tetramethylpyrrolidine (CPH and ESR spectroscopy. We then employed this technique to characterize hypoxia-dependent ROS release, with specific attention paid to NADPH oxidase-dependent superoxide formation as a possible vasoconstrictor pathway. Results While perfusing lungs with CPH over a range of inspired oxygen concentrations (1–21 %, the rate of CP• formation exhibited an oxygen-dependence, with a minimum at 2.5 % O2. Addition of superoxide dismutase (SOD to the buffer fluid illustrated that a minor proportion of this intravascular ROS leak was attributable to superoxide. Stimulation of the lungs by injection of phorbol-12-myristate-13-acetate (PMA into the pulmonary artery caused a rapid increase in CP• formation, concomitant with pulmonary vasoconstriction. Both the PMA-induced CPH oxidation and the vasoconstrictor response were largely suppressed by SOD. When the PMA challenge was performed at different oxygen concentrations, maximum superoxide liberation and pulmonary vasoconstriction occurred at 5 % O2. Using a NADPH oxidase inhibitor and NADPH-oxidase deficient mice, we illustrated that the PMA-induced superoxide release was attributable to the stimulation of NADPH oxidases. Conclusion The perfusion of isolated lungs with CPH is suitable for detection of intravascular ROS release by ESR spectroscopy. We employed this technique to

  14. 3D Interpolation Method for CT Images of the Lung

    Directory of Open Access Journals (Sweden)

    Noriaki Asada

    2003-06-01

    Full Text Available A 3-D image can be reconstructed from numerous CT images of the lung. The procedure reconstructs a solid from multiple cross section images, which are collected during pulsation of the heart. Thus the motion of the heart is a special factor that must be taken into consideration during reconstruction. The lung exhibits a repeating transformation synchronized to the beating of the heart as an elastic body. There are discontinuities among neighboring CT images due to the beating of the heart, if no special techniques are used in taking CT images. The 3-D heart image is reconstructed from numerous CT images in which both the heart and the lung are taken. Although the outline shape of the reconstructed 3-D heart is quite unnatural, the envelope of the 3-D unnatural heart is fit to the shape of the standard heart. The envelopes of the lung in the CT images are calculated after the section images of the best fitting standard heart are located at the same positions of the CT images. Thus the CT images are geometrically transformed to the optimal CT images fitting best to the standard heart. Since correct transformation of images is required, an Area oriented interpolation method proposed by us is used for interpolation of transformed images. An attempt to reconstruct a 3-D lung image by a series of such operations without discontinuity is shown. Additionally, the same geometrical transformation method to the original projection images is proposed as a more advanced method.

  15. CT quantification of lung and airways in normal Korean subjects

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Soo; Lee, Jeong Eun; Shin, Hye Soo [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of); Jin, Gong Yong; Li, Yuan Zhe [Dept. of Radiology, Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2017-08-01

    To measure and compare the quantitative parameters of the lungs and airways in Korean never-smokers and current or former smokers (“ever-smokers”). Never-smokers (n = 119) and ever-smokers (n = 45) who had normal spirometry and visually normal chest computed tomography (CT) results were retrospectively enrolled in this study. For quantitative CT analyses, the low attenuation area (LAA) of LAA{sub I-950}, LAA{sub E-856}, CT attenuation value at the 15th percentile, mean lung attenuation (MLA), bronchial wall thickness of inner perimeter of a 10 mm diameter airway (Pi10), total lung capacity (TLC{sub CT}), and functional residual capacity (FRC{sub CT}) were calculated based on inspiratory and expiratory CT images. To compare the results between groups according to age, sex, and smoking history, independent t test, one way ANOVA, correlation test, and simple and multiple regression analyses were performed. The values of attenuation parameters and volume on inspiratory and expiratory quantitative computed tomography (QCT) were significantly different between males and females (p < 0.001). The MLA and the 15th percentile value on inspiratory QCT were significantly lower in the ever-smoker group than in the never-smoker group (p < 0.05). On expiratory QCT, all lung attenuation parameters were significantly different according to the age range (p < 0.05). Pi10 in ever-smokers was significantly correlated with forced expiratory volume in 1 second/forced vital capacity (r = −0.455, p = 0.003). In simple and multivariate regression analyses, TLC{sub CT}, FRC{sub CT}, and age showed significant associations with lung attenuation (p < 0.05), and only TLC{sub CT} was significantly associated with inspiratory Pi10. In Korean subjects with normal spirometry and visually normal chest CT, there may be significant differences in QCT parameters according to sex, age, and smoking history.

  16. CT Perfusion for Early Response Evaluation of Radiofrequency Ablation of Focal Liver Lesions: First Experience

    Energy Technology Data Exchange (ETDEWEB)

    Marquez, Herman P., E-mail: hermanpaulo.marquezmasquiaran@usz.ch; Puippe, Gilbert; Mathew, Rishi Philip; Alkadhi, Hatem; Pfammatter, Thomas; Fischer, Michael A. [University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Institute of Diagnostic and Interventional Radiology (Switzerland)

    2017-01-15

    PurposeTo investigate the value of perfusion CT (P-CT) for early assessment of treatment response in patients undergoing radiofrequency ablation (RFA) of focal liver lesions.Methods and Materials20 consecutive patients (14 men; mean age 64 ± 14) undergoing P-CT within 24 h after RFA of liver metastases (n = 10) or HCC (n = 10) were retrospectively included. Two readers determined arterial liver perfusion (ALP, mL/min/100 mL), portal liver perfusion (PLP, mL/min/100 mL), and hepatic perfusion index (HPI, %) in all post-RFA lesions by placing a volume of interest in the necrotic central (CZ), the transition (TZ), and the surrounding parenchymal (PZ) zone. Patients were classified into complete responders (no residual tumor) and incomplete responders (residual/progressive tumor) using imaging follow-up with contrast-enhanced CT or MRI after a mean of 57 ± 30 days. Prediction of treatment response was evaluated using the area under the curve (AUC) from receiver operating characteristic analysis.ResultsMean ALP/PLP/HPI of both readers were 4.8/15.4/61.2 for the CZ, 9.9/16.8/66.3 for the TZ and 20.7/29.0/61.8 for the PZ. Interreader agreement of HPI was fair for the CZ (intraclass coefficient 0.713), good for the TZ (0.813), and excellent for the PZ (0.920). For both readers, there were significant differences in HPI of the CZ and TZ between responders and nonresponders (both, P < 0.05). HPI of the TZ showed the highest AUC (0.911) for prediction of residual tumor, suggesting a cut-off value of 76 %.ConclusionIncreased HPI of the transition zone assessed with P-CT after RFA might serve as an early quantitative biomarker for residual tumor in patients with focal liver lesions.

  17. TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps

    NARCIS (Netherlands)

    A. Mendrik (Adrienne); E.J.P.A. Vonken; B.T.J. van Ginneken (Berbke); J.R. Riordan (John ); H.W.A.M. de Jong (Hugo); T. van Seeters (Tom); E.J. Smit (Ewoud); M.A. Viergever (Max); M. Prokop (Mathias)

    2011-01-01

    textabstractCerebral computed tomography perfusion (CTP) scans are acquired to detect areas of abnormal perfusion in patients with cerebrovascular diseases. These 4D CTP scans consist of multiple sequential 3D CT scans over time. Therefore, to reduce radiation exposure to the patient, the amount of

  18. High resolution CT in diffuse lung disease

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.)

  19. High resolution CT in diffuse lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.).

  20. The diagnostic value of PET-CT on peripheral lung cancer

    International Nuclear Information System (INIS)

    Li Lebao; Peng Xiang; Ye Hui; Mo Yi; Xie Aimin

    2010-01-01

    Objective: To evaluate the value of PET-CT in the diagnosis of peripheral lung cancer. cancer proved pathology characteristics and standardized uptake value (SUV) of 70 patients with lung cancer proved by pathology were analyzed retrospectively. Results: Of the 70 cases, 32 cases were squamous carcinoma, 25 cases were adenocarcinoma, 8 cases were small cell lung cancer, 3 cases were adenosquamous carcinoma and 2 cases were megacell lung cancer. The average SUV of the lung cancer was 4.94±1.53. In the group of lung cancer, hypermetabolic lesions were found in 66 cases and the SUV was more than 2.5 while the SUV was less than 2.5 in 4 cases. Positive correlation was showed in the SUV and the size of tumors. Conclusions: The peripheral lung cancer has its special imaging appearances of PET-CT. PET-CT is an excellent modality in the diagnosis and differential diagnosis of preipheral lung cancer. The SUV combining with morphological findings sometimes may be helpful for the differential diagnosis. (authors)

  1. Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: acquisition technique, post-processing and initial results

    International Nuclear Information System (INIS)

    Kandel, Sonja; Kloeters, Christian; Meyer, Henning; Hein, Patrick; Rogalla, Patrik; Hilbig, Andreas

    2009-01-01

    The purpose of this study was to evaluate a whole-organ perfusion protocol of the pancreas in patients with primary pancreas carcinoma and to analyse perfusion differences between normal and diseased pancreatic tissue. Thirty patients with primary pancreatic malignancy were imaged on a 320-slice CT unit. Twenty-nine cancers were histologically proven. CT data acquisition was started manually after contrast-material injection (8 ml/s, 350 mg iodine/ml) and dynamic density measurements in the right ventricle. After image registration, perfusion was determined with the gradient-relationship technique and volume regions-of-interest were defined for perfusion measurements. Contrast time-density curves and perfusion maps were generated. Statistical analysis was performed using the Kolmogorov-Smirnov test for analysis of normal distribution and Kruskal-Wallis test (nonparametric ANOVA) with Bonferroni correction for multiple stacked comparisons. In all 30 patients the entire pancreas was imaged, and registration could be completed in all cases. Perfusion of pancreatic carcinomas was significantly lower than of normal pancreatic tissue (P < 0.001) and could be visualized on colored perfusion maps. The 320-slice CT allows complete dynamic visualization of the pancreas and enables calculation of whole-organ perfusion maps. Perfusion imaging carries the potential to improve detection of pancreatic cancers due to the perfusion differences. (orig.)

  2. CT features of lung cancer associated with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Kim, Jun Hyoung; Song, Koun Sik; Lee, Deok Hee; Kim, Jin Suh; Lim, Tae Hwan

    1996-01-01

    It is well known that the incidence of lung cancer is high in patients with idiopathic pulmonary fibrosis(IPF). We analyzed the CT features of lung cancer associated with IPF. Retrospective analyzed the CT features of lung cancer associated with IPF. Retrospective analysis was performed in 23 patients with lung cancer(24 lung cancers) associated with IPF. The diagnosis of IPF was made by clinical and CT findings, and lung cancer was confirmed pathologically. We divided the location of lung cancer by lobar distribution and central or peripheral lung zone, and measured the size of mass. We classified the mediastinal lymph node enlargement by American Thoracic Society (ATS) mapping scheme. We evaluated the CT pattern of IPF. The subjects consisted of 6 cases of small cell carcinoma and 18 cases of non-small cell lung cancer. Non-small cell lung cancers were located in the right upper lobe in 5 cases, left upper lobe in 6 cases, right middle lobe in 1 case, right lower lobe in 9 cases, and left lower lobe in 3 cases. Twenty cancers(85%) were located in the peripheral lung zone. Eighteen cancers(73%) were surrounded by fibrotic lung. The size of the mass ranged from 1 to 12 cm, and in 12 cases it was below 3cm in diameter. Mediastinal lymph nodes were enlarged in 22 cases(92%) and classified as N2 or N3 in 15 cases out of 18 non-small cell lung. The size of the mass ranged from 1 to 12 cm, and in 12 cases it was below 3 cm in diameter. Mediastinal lymph nodes were enlarged in 22 cases(92%) and classified as N2 or N3 in 15 cases out of 18 non-small cell lung cancers. CT patterns of underlying IPF were honey-combing in 18 patients(78%) and mixed honey-combing and ground-glass opacity in 5 patients(22%). The lung cancer associated with IPF shows variable cell types. Most of the lung cancers were located peripherally, surrounded by end-stage fibrosis, and were associated with mediastinal lymph node enlargement

  3. CT features of lung cancer associated with idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Hyoung; Song, Koun Sik; Lee, Deok Hee; Kim, Jin Suh; Lim, Tae Hwan [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-01-01

    It is well known that the incidence of lung cancer is high in patients with idiopathic pulmonary fibrosis(IPF). We analyzed the CT features of lung cancer associated with IPF. Retrospective analyzed the CT features of lung cancer associated with IPF. Retrospective analysis was performed in 23 patients with lung cancer(24 lung cancers) associated with IPF. The diagnosis of IPF was made by clinical and CT findings, and lung cancer was confirmed pathologically. We divided the location of lung cancer by lobar distribution and central or peripheral lung zone, and measured the size of mass. We classified the mediastinal lymph node enlargement by American Thoracic Society (ATS) mapping scheme. We evaluated the CT pattern of IPF. The subjects consisted of 6 cases of small cell carcinoma and 18 cases of non-small cell lung cancer. Non-small cell lung cancers were located in the right upper lobe in 5 cases, left upper lobe in 6 cases, right middle lobe in 1 case, right lower lobe in 9 cases, and left lower lobe in 3 cases. Twenty cancers(85%) were located in the peripheral lung zone. Eighteen cancers(73%) were surrounded by fibrotic lung. The size of the mass ranged from 1 to 12 cm, and in 12 cases it was below 3cm in diameter. Mediastinal lymph nodes were enlarged in 22 cases(92%) and classified as N2 or N3 in 15 cases out of 18 non-small cell lung. The size of the mass ranged from 1 to 12 cm, and in 12 cases it was below 3 cm in diameter. Mediastinal lymph nodes were enlarged in 22 cases(92%) and classified as N2 or N3 in 15 cases out of 18 non-small cell lung cancers. CT patterns of underlying IPF were honey-combing in 18 patients(78%) and mixed honey-combing and ground-glass opacity in 5 patients(22%). The lung cancer associated with IPF shows variable cell types. Most of the lung cancers were located peripherally, surrounded by end-stage fibrosis, and were associated with mediastinal lymph node enlargement.

  4. CT perfusion: the clinical application in the diagnosis of breast diseases

    International Nuclear Information System (INIS)

    Ye Zhaoxiang; Song Xiuyu; Xiao Jianyu

    2005-01-01

    Objective: To assess the CT perfusion characteristics of breast diseases. Methods: Twenty-two patients with fibroadenoma accompanied with cyst (n=1), other benign diseases (n=5), and carcinomas (n=16) underwent breast CT scan. CT perfusion was performed for breast with cine mode (0.5 s per rotation ) on a multislice CT scanner, 120 kV, 60 mA, 4 x 5 mm collimation. Contrast injection was done by using 50 ml nonionic contrast agent (300 mg I/ml ), at a flow rate of 4 ml/s with a power injector, 5 seconds delay, and data acquisition lasted for 50 seconds. These data were processed on a GE AW 4.1 workstation using perfusion 3 software package, and the mean BF, BV, MTT and PS were measured and statistically analyzed. Results: The mean BF, BV, MTT and PS in carcinoma were (33.55 ± 28.40) ml·min -1 ·100 g -1 , (5.60±3.08) ml/100 g, (15.37±6.41) s, (18.71±10.42) ml· min -1 ·100 g -1 . The mean BF, BV, MTT and PS in contralateral normal breast of carcinoma were (10.36 ± 9.44) ml·min -1 ·100 g -1 , (0.70±0.22) ml/100 g, (13.55 ± 7.27) s, (1.54±1.74) ml·min -1 ·100 g -1 . The mean BF, BV, and PS between carcinoma and normal breast were statistically significant (P 0.05). The mean BF, BV, MTT and PS in fibroadenoma were (62.57 ± 19.62) ml·min -1 ·100 g -1 , (7.37 ±1.30) ml/100 g, (11.24 ± 3.34) s, (27.63 ± 3.87) ml·min -1 ·100 g -1 . The mean PS between carcinoma and fibroadenoma was statistically significant (P 0.05). The mean BF, BV, MTT and PS in benign lesion were (7.65 ± 10.24) ml·min -1 ·100 g -1 , (1.23 ± 0.97) ml/100 g, (14.94 ± 10.68) s, (1.81 ± 1.72) ml·min -1 ·100 g -1 . The mean BF, BV, and PS between carcinoma and benign lesion were statistically significant (P 0.05). Conclusion: MSCT perfusion may reflect the features of breast diseases, and provide valuable hemodynamic message. These parameters have a value in diagnosis of breast diseases and are helpful for differential diagnosis. (authors)

  5. CT-quantified emphysema distribution is associated with lung function decline

    NARCIS (Netherlands)

    Hoesein, F.A.A.M.; Rikxoort, E.M. van; Ginneken, B. van; de Jong, P. A.; Prokop, M.; Lammers, J.W.; Zanen, P.

    2012-01-01

    Emphysema distribution is associated with COPD. It is however unknown whether CT-quantified emphysema distribution (upper/lower lobe) is associated with lung function decline in heavy (former) smokers.587 male participants underwent lung CT-scanning and pulmonary function testing at baseline and

  6. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    International Nuclear Information System (INIS)

    Hanson, Eric H.; Roach, Cayce J.; Ringdahl, Erik N.; Wynn, Brad L.; DeChancie, Sean M.; Mann, Nathan D.; Diamond, Alan S.; Orrison, William W.

    2011-01-01

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  7. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Eric H. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); Amigenics, Inc, Las Vegas, NV (United States); Roach, Cayce J. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); University of Nevada Las Vegas, School of Life Sciences, Las Vegas, NV (United States); Ringdahl, Erik N. [University of Nevada Las Vegas, Department of Psychology, Las Vegas, NV (United States); Wynn, Brad L. [Family Medicine Spokane, Spokane, WA (United States); DeChancie, Sean M.; Mann, Nathan D. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); Diamond, Alan S. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); Orrison, William W. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); University of Nevada School of Medicine, Department of Medical Education, Reno, NV (United States)

    2011-05-15

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  8. Automated lung volumetry from routine thoracic CT scans: how reliable is the result?

    Science.gov (United States)

    Haas, Matthias; Hamm, Bernd; Niehues, Stefan M

    2014-05-01

    Today, lung volumes can be easily calculated from chest computed tomography (CT) scans. Modern postprocessing workstations allow automated volume measurement of data sets acquired. However, there are challenges in the use of lung volume as an indicator of pulmonary disease when it is obtained from routine CT. Intra-individual variation and methodologic aspects have to be considered. Our goal was to assess the reliability of volumetric measurements in routine CT lung scans. Forty adult cancer patients whose lungs were unaffected by the disease underwent routine chest CT scans in 3-month intervals, resulting in a total number of 302 chest CT scans. Lung volume was calculated by automatic volumetry software. On average of 7.2 CT scans were successfully evaluable per patient (range 2-15). Intra-individual changes were assessed. In the set of patients investigated, lung volume was approximately normally distributed, with a mean of 5283 cm(3) (standard deviation = 947 cm(3), skewness = -0.34, and curtosis = 0.16). Between different scans in one and the same patient the median intra-individual standard deviation in lung volume was 853 cm(3) (16% of the mean lung volume). Automatic lung segmentation of routine chest CT scans allows a technically stable estimation of lung volume. However, substantial intra-individual variations have to be considered. A median intra-individual deviation of 16% in lung volume between different routine scans was found. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  9. SU-E-J-86: Lobar Lung Function Quantification by PET Galligas and CT Ventilation Imaging in Lung Cancer Patients

    International Nuclear Information System (INIS)

    Eslick, E; Kipritidis, J; Keall, P; Bailey, D; Bailey, E

    2014-01-01

    Purpose: The purpose of this study was to quantify the lobar lung function using the novel PET Galligas ([68Ga]-carbon nanoparticle) ventilation imaging and the investigational CT ventilation imaging in lung cancer patients pre-treatment. Methods: We present results on our first three lung cancer patients (2 male, mean age 78 years) as part of an ongoing ethics approved study. For each patient a PET Galligas ventilation (PET-V) image and a pair of breath hold CT images (end-exhale and end-inhale tidal volumes) were acquired using a Siemens Biograph PET CT. CT-ventilation (CT-V) images were created from the pair of CT images using deformable image registration (DIR) algorithms and the Hounsfield Unit (HU) ventilation metric. A comparison of ventilation quantification from each modality was done on the lobar level and the voxel level. A Bland-Altman plot was used to assess the difference in mean percentage contribution of each lobe to the total lung function between the two modalities. For each patient, a voxel-wise Spearmans correlation was calculated for the whole lungs between the two modalities. Results: The Bland-Altman plot demonstrated strong agreement between PET-V and CT-V for assessment of lobar function (r=0.99, p<0.001; range mean difference: −5.5 to 3.0). The correlation between PET-V and CT-V at the voxel level was moderate(r=0.60, p<0.001). Conclusion: This preliminary study on the three patients data sets demonstrated strong agreement between PET and CT ventilation imaging for the assessment of pre-treatment lung function at the lobar level. Agreement was only moderate at the level of voxel correlations. These results indicate that CT ventilation imaging has potential for assessing pre-treatment lobar lung function in lung cancer patients

  10. Quantitative myocardial perfusion from static cardiac and dynamic arterial CT

    Science.gov (United States)

    Bindschadler, Michael; Branch, Kelley R.; Alessio, Adam M.

    2018-05-01

    Quantitative myocardial blood flow (MBF) estimation by dynamic contrast enhanced cardiac computed tomography (CT) requires multi-frame acquisition of contrast transit through the blood pool and myocardium to inform the arterial input and tissue response functions. Both the input and the tissue response functions for the entire myocardium are sampled with each acquisition. However, the long breath holds and frequent sampling can result in significant motion artifacts and relatively high radiation dose. To address these limitations, we propose and evaluate a new static cardiac and dynamic arterial (SCDA) quantitative MBF approach where (1) the input function is well sampled using either prediction from pre-scan timing bolus data or measured from dynamic thin slice ‘bolus tracking’ acquisitions, and (2) the whole-heart tissue response data is limited to one contrast enhanced CT acquisition. A perfusion model uses the dynamic arterial input function to generate a family of possible myocardial contrast enhancement curves corresponding to a range of MBF values. Combined with the timing of the single whole-heart acquisition, these curves generate a lookup table relating myocardial contrast enhancement to quantitative MBF. We tested the SCDA approach in 28 patients that underwent a full dynamic CT protocol both at rest and vasodilator stress conditions. Using measured input function plus single (enhanced CT only) or plus double (enhanced and contrast free baseline CT’s) myocardial acquisitions yielded MBF estimates with root mean square (RMS) error of 1.2 ml/min/g and 0.35 ml/min/g, and radiation dose reductions of 90% and 83%, respectively. The prediction of the input function based on timing bolus data and the static acquisition had an RMS error compared to the measured input function of 26.0% which led to MBF estimation errors greater than threefold higher than using the measured input function. SCDA presents a new, simplified approach for quantitative

  11. Lung Dose Calculation With SPECT/CT for 90Yittrium Radioembolization of Liver Cancer

    International Nuclear Information System (INIS)

    Yu, Naichang; Srinivas, Shaym M.; DiFilippo, Frank P.; Shrikanthan, Sankaran; Levitin, Abraham; McLennan, Gordon; Spain, James; Xia, Ping; Wilkinson, Allan

    2013-01-01

    Purpose: To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ( 99m Tc-MAA) single photon emission CT (SPECT)/CT for 90 Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Methods and Materials: Images of 71 patients who had SPECT/CT and PS images of 99m Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. Results: The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. Conclusions: A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on 99m Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended

  12. TU-CD-BRA-08: Single-Energy Computed Tomography-Based Pulmonary Perfusion Imaging: Proof-Of-Principle in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, T; Boone, J [University of California Davis School of Medicine, Sacramento, CA (United States); Kent, M; Wisner, E [University of California Davis School of Veterinary Medicine, Davis, CA (United States); Fujita, Y [Tokai University, Isehara (Japan)

    2015-06-15

    Purpose: Pulmonary perfusion imaging has provided significant insights into pulmonary diseases, and can be useful in radiotherapy. The purpose of this study was to prospectively establish proof-of-principle in a canine model for single-energy CT-based perfusion imaging, which has the potential for widespread clinical implementation. Methods: Single-energy CT perfusion imaging is based on: (1) acquisition of inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast medium, (2) deformable image registration (DIR) of the two CT image data sets, and (3) subtraction of the pre-contrast image from post-contrast image, yielding a map of Hounsfield unit (HU) enhancement. These subtraction image data sets hypothetically represent perfused blood volume, a surrogate for perfusion. In an IACUC-approved clinical trial, we acquired pre- and post-contrast CT scans in the prone posture for six anesthetized, mechanically-ventilated dogs. The elastix algorithm was used for DIR. The registration accuracy was quantified using the target registration errors (TREs) for 50 pulmonary landmarks in each dog. The gradient of HU enhancement between gravity-dependent (ventral) and non-dependent (dorsal) regions was evaluated to quantify the known effect of gravity, i.e., greater perfusion in ventral regions. Results: The lung volume difference between the two scans was 4.3±3.5% on average (range 0.3%–10.1%). DIR demonstrated an average TRE of 0.7±1.0 mm. HU enhancement in lung parenchyma was 34±10 HU on average and varied considerably between individual dogs, indicating the need for improvement of the contrast injection protocol. HU enhancement in ventral (gravity-dependent) regions was found to be greater than in dorsal regions. A population average ventral-to-dorsal gradient of HU enhancement was strong (R{sup 2}=0.94) and statistically significant (p<0.01). Conclusion: This canine study demonstrated relatively accurate DIR and a strong ventral

  13. TU-CD-BRA-08: Single-Energy Computed Tomography-Based Pulmonary Perfusion Imaging: Proof-Of-Principle in a Canine Model

    International Nuclear Information System (INIS)

    Yamamoto, T; Boone, J; Kent, M; Wisner, E; Fujita, Y

    2015-01-01

    Purpose: Pulmonary perfusion imaging has provided significant insights into pulmonary diseases, and can be useful in radiotherapy. The purpose of this study was to prospectively establish proof-of-principle in a canine model for single-energy CT-based perfusion imaging, which has the potential for widespread clinical implementation. Methods: Single-energy CT perfusion imaging is based on: (1) acquisition of inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast medium, (2) deformable image registration (DIR) of the two CT image data sets, and (3) subtraction of the pre-contrast image from post-contrast image, yielding a map of Hounsfield unit (HU) enhancement. These subtraction image data sets hypothetically represent perfused blood volume, a surrogate for perfusion. In an IACUC-approved clinical trial, we acquired pre- and post-contrast CT scans in the prone posture for six anesthetized, mechanically-ventilated dogs. The elastix algorithm was used for DIR. The registration accuracy was quantified using the target registration errors (TREs) for 50 pulmonary landmarks in each dog. The gradient of HU enhancement between gravity-dependent (ventral) and non-dependent (dorsal) regions was evaluated to quantify the known effect of gravity, i.e., greater perfusion in ventral regions. Results: The lung volume difference between the two scans was 4.3±3.5% on average (range 0.3%–10.1%). DIR demonstrated an average TRE of 0.7±1.0 mm. HU enhancement in lung parenchyma was 34±10 HU on average and varied considerably between individual dogs, indicating the need for improvement of the contrast injection protocol. HU enhancement in ventral (gravity-dependent) regions was found to be greater than in dorsal regions. A population average ventral-to-dorsal gradient of HU enhancement was strong (R"2=0.94) and statistically significant (p<0.01). Conclusion: This canine study demonstrated relatively accurate DIR and a strong ventral

  14. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  15. Impact of CT perfusion imaging on the assessment of peripheral chronic pulmonary thromboembolism: clinical experience in 62 patients

    Energy Technology Data Exchange (ETDEWEB)

    Le Faivre, Julien; Khung, Suonita; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Duhamel, Alain [University of Lille, Department of Biostatistics, Lille (France); Lamblin, Nicolas [University of Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2016-11-15

    To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. (orig.)

  16. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    International Nuclear Information System (INIS)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva; Elsner, Andreas; Bolte, Matthias; Domik, Gitta; Hoff, Joerg van den

    2009-01-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  17. Low-dose CT: new tool for screening lung cancer?

    International Nuclear Information System (INIS)

    Diederich, S.; Wormanns, D.; Heindel, W.

    2001-01-01

    Lung cancer is the leading cause of death from malignant tumours as it is very common and has a poor prognosis at advanced tumour stages. Prognosis could be improved by treatment at early stages. As these stages are usually asymptomatic, a diagnostic test that would allow detection of early tumour stages in a population at risk could potentially reduce mortality from lung cancer. Previous approaches using chest radiography and sputum cytology in smokers have been disappointing. Fluorescent bronchoscopy and molecular markers are not yet applicable in clinical routine. Because of its high sensitivity for small pulmonary nodules, which are the most common manifestation of early lung cancer, CT appears suitable as a screening test. Low-dose examination parameters can and should be used for this purpose. From clinical practice it is well known that chest CT often demonstrates small pulmonary nodules, which do not represent lung cancer. Therefore, non-invasive diagnostic algorithms are required to avoid unnecessary biopsies in benign lesions. In preliminary studies of low-dose CT using algorithms based on size and density of detected nodules a large proportion of asymptomatic lung cancers and a large proportion of early, resectable tumour stages were found with a small proportion of invasive procedures for benign nodules. Before this technology can be recommended for broad application, however, further information is required regarding appropriate inclusion criteria (smoking habits, age groups) and screening intervals. Most importantly, further data are required to clarify whether lung cancer screening using low-dose CT can actually reduce mortality from lung cancer. (orig.)

  18. The 'fragmented' scintigraphic lung pattern in pulmonary lymphangitic carcinomatosis secondary to breast cancer.

    Science.gov (United States)

    Vattimo, A V; Burroni, L; Bertelli, P; Vella, A; Volterrani, D

    1998-01-01

    Pulmonary lymphangitic carcinomatosis (PLC) is an unusual presentation of diffuse infiltrative lung disease. In this report we present two cases secondary to breast cancer; the diagnosis was made by means of transbronchial lung biopsy or postmortem examination. The goal of this study was to analyze the scintigraphic pattern of pulmonary perfusion performed with technetium-99m macroaggregated albumin (99mTc-MAA) in the hope of achieving improved recognition of PLC and its subsequent diagnosis. Upon admission, both patients underwent routine clinical exams followed by chest X-rays. The second patient also underwent CT examination, and both were ultimately examined using pulmonary perfusion scintigraphy with 99mTc-MAA. In the various exams performed, the most reliable and easily identified diagnostic finding turned out to be a characteristic 'fragmented' lung pattern revealed with the perfusion lung scan. Unfortunately, in both cases the patients' conditions rapidly worsened and death occurred shortly following scintigraphy. We were able to conclude that the recognition of the mentioned fragmented scintigraphic lung pattern may be useful in suspected PLC, whereas the nonspecific clinical presentation of this pathology makes diagnosis extremely difficult, with the most significant results being achieved through a comparison of scintigraphic and high resolution CT data.

  19. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  20. CT perfusion mapping of hemodynamic disturbances associated to acute spontaneous intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Fainardi, Enrico; Borrelli, Massimo; Saletti, Andrea; Ceruti, Stefano; Tamarozzi, Riccardo; Schivalocchi, Roberta; Cavallo, Michele; Azzini, Cristiano; Chieregato, Arturo

    2008-01-01

    We sought to quantify perfusion changes associated to acute spontaneous intracerebral hemorrhage (SICH) by means of computed tomography perfusion (CTP) imaging. We studied 89 patients with supratentorial SICH at admission CT by using CTP scanning obtained within 24 h after symptom onset. Regional cerebral blood flow (rCBF), cerebral blood volume (rCBV) and mean transit time (rMTT) levels were measured in four different regions of interest manually outlined on CT scan: (1) hemorrhagic core; (2) perihematomal low-density area; (3) 1 cm rim of normal-appearing brain tissue surrounding the perilesional area; and (4) a mirrored area, including the clot and the perihematomal region, located in the non-lesioned contralateral hemisphere. rCBF, rCBV, and rMTT mean levels showed a centrifugal distribution with a gradual increase from the core to the periphery (p 20 ml) hematomas (p<0.01 and p <0.02, respectively). Multi-parametric CTP mapping of acute SICH indicates that perfusion values show a progressive improvement from the core to the periphery. In the first 24 h, perihemorrhagic region was hypoperfused with CTP values which were not suggestive of ischemic penumbra destined to survive but more likely indicative of edema formation. These findings also argue for a potential influence of early amounts of bleeding on perihematomal hemodynamic abnormalities. (orig.)

  1. Lung perfusion in hemorrhagic shock of rats. The effects of resuscitation with whole blood, saline or hes 6%

    Energy Technology Data Exchange (ETDEWEB)

    Turhanoglu, S.; Kaya, S.; Kararmaz, A.; Turhanoglu, A.D. [Dicle Univ., Diyarbakir (Turkey). Medical School

    2001-12-01

    This study was undertaken to determine the effects of various resuscitation regimens on lung perfusion following resuscitation from hemorrhagic shock. Fourty male Sprague-Dawley rats (250-300 g) were used. The rats were divided randomly into four groups (n=10 for each) and were sedated with intramuscular ketamine (100 mg/kg). We measured blood pressure, rectal temperature and lung perfusion using radioscintigraphy with a technetium colloid indicator. The systolic blood pressure was decreased 75% by removing blood via v. jugularis in the first three groups and group 4 was accepted as the control group, and blood volume was not diminished. Then the first three groups were resuscitated with autologous blood containing 125 units heparine/ml in group 1, saline in group 2, and hydroxyethyl starch (HES) 6% in group 3. After the correction of hypovolemia, all animals were injected 100 Bg (0.1 cc) technetium 99m macroaggregated albumin ({sup 99m}Tc MAA) via penil vein. After injection of {sup 99m}Tc MAA, 3 minutes fixed images were detected by a {gamma} camera in posterior position at 15 minutes and 5 hours. {sup 99m}Tc MMA ''wash out'' rate in lung was determined quantitatively at 5 hours. Compared to a control group, lung perfusion was decreased significantly in groups resuscitated with saline, and HES 6% while perfusion was restored with autologous blood. We conclude that heparinized autologous blood saved lung capillary circulation in hemorrhagic shock in rats. (author)

  2. Lung perfusion in hemorrhagic shock of rats. The effects of resuscitation with whole blood, saline or hes 6%

    International Nuclear Information System (INIS)

    Turhanoglu, S.; Kaya, S.; Kararmaz, A.; Turhanoglu, A.D.

    2001-01-01

    This study was undertaken to determine the effects of various resuscitation regimens on lung perfusion following resuscitation from hemorrhagic shock. Fourty male Sprague-Dawley rats (250-300 g) were used. The rats were divided randomly into four groups (n=10 for each) and were sedated with intramuscular ketamine (100 mg/kg). We measured blood pressure, rectal temperature and lung perfusion using radioscintigraphy with a technetium colloid indicator. The systolic blood pressure was decreased 75% by removing blood via v. jugularis in the first three groups and group 4 was accepted as the control group, and blood volume was not diminished. Then the first three groups were resuscitated with autologous blood containing 125 units heparine/ml in group 1, saline in group 2, and hydroxyethyl starch (HES) 6% in group 3. After the correction of hypovolemia, all animals were injected 100 Bg (0.1 cc) technetium 99m macroaggregated albumin ( 99m Tc MAA) via penil vein. After injection of 99m Tc MAA, 3 minutes fixed images were detected by a γ camera in posterior position at 15 minutes and 5 hours. 99m Tc MMA ''wash out'' rate in lung was determined quantitatively at 5 hours. Compared to a control group, lung perfusion was decreased significantly in groups resuscitated with saline, and HES 6% while perfusion was restored with autologous blood. We conclude that heparinized autologous blood saved lung capillary circulation in hemorrhagic shock in rats. (author)

  3. CT imaging of coexisting pulmonary tuberculosis and lung cancer

    International Nuclear Information System (INIS)

    Lv Yan; Xie Ruming; Zhou Xinhua; Zhou Zhen; Xu Jinping; He Wei; Guo Lifang; Ning Fenggang

    2013-01-01

    Objective: To study the CT characteristics of coexisting pulmonary tuberculosis and lung cancer. Methods: One hundred and four patients of coexisting pulmonary tuberculosis and lung cancer proved by histology, cytology or clinical underwent CT examination. All patients were divided into two groups, group Ⅰ were the patients with the lung cancer after tuberculosis or both found simultaneously (group Ⅰ a with peripheral lung cancer and group Ⅰ b with central lung cancer), group Ⅱ with tuberculosis during lung cancer chemotherapy (group Ⅱ a with peripheral lung cancer and group Ⅱ b with central lung cancer). Imaging characteristics of tuberculosis and lung cancer were compared. χ"2 test and t test were used for the statistical analysis. Results: Of 104 patients, there were 92 patients (88.5%) in group Ⅰ and 12 patients (11.5%) in group Ⅱ. Seventy patients (76.1%) of lung cancer and tuberculosis were located in the same lobe and 22 patients (23.9%) in the different lobes in group Ⅰ. There was no significant difference in distribution of tuberculosis between group Ⅰ and group Ⅱ (χ"2 = 4.302, P = 0.507). The fibrous stripes, nodules of calcification and pleural adhesion of tuberculosis were statistically significant between the two groups (χ"2 = 22.737, 15.193, 27.792, P < 0.05). There were 33 central lung cancers and 71 peripheral lung cancers. In group Ⅰ a (64 patients of peripheral lung cancers), 39 patients (60.9%) had typical manifestations and most of the lesions were ≥ 3 cm (n = 49, 76.6%), solid lesions showed variable enhancement. Conclusions: Secondary tuberculosis during lung cancer chemotherapy has the same CT characteristics with the common active tuberculosis. The morphology, enhancement pattern of lesion and follow-up are helpful for the diagnosis of lung cancer after tuberculosis. (authors)

  4. Image quality in CT perfusion imaging of the brain. The role of iodine concentration

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Matthias; Bueltmann, Eva; Bode-Schnurbus, Lucas; Koenen, Dirk; Mielke, Eckhart; Heuser, Lothar [Knappschaftskrankenhaus Langendreer, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Ruhr-University Bochum, Bochum (Germany)

    2007-01-15

    The purpose of this study was to evaluate the impact of various iodine contrast concentrations on image quality in computed tomography (CT) perfusion studies. Twenty-one patients with suspicion of cerebral ischemia underwent perfusion CT using two different iodine contrast concentrations: 11 patients received iomeprol 300 (iodine concentration: 300 mg/ml) while ten received the same volume of iomeprol 400 (iodine concentration: 400 mg/ml). Scan parameters were kept constant for both groups. Maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and time to peak (TTP) were calculated from two adjacent slices. Quantitative comparisons were based on measurements of the maximum enhancement [Hounsfield units (HU)] and signal-to-noise index (SNI) on CBF, CBV, and TTP images. Determinations of grey-to-white-matter delineation for each iodine concentration were performed by two blinded readers. Only data from the non-ischemic hemispheres were considered. Both maximum enhancement and SNI values were higher after iomeprol 400, resulting in significantly better image quality in areas of low perfusion. No noteworthy differences were found for normal values of CBF, CBV, and TTP. Qualitative assessment of grey/white matter contrast on CBF and CBV maps revealed better performance for iomeprol 400. For brain perfusion studies, highly concentrated contrast media such as iomeprol 400 is superior to iomeprol 300. (orig.)

  5. Detection of lung nodules with low-dose spiral CT: comparison with conventional dose CT

    International Nuclear Information System (INIS)

    Zhu Tianzhao; Tang Guangjian; Jiang Xuexiang

    2004-01-01

    Objective: To investigate the effect of reducing scan dose on the lung nodules detection rate by scanning a lung nodule model at low dose and conventional dose. Methods: The lung and the thoracic cage were simulated by using a cyst filled with water surrounded by a roll bandage. Flour, butter, and paraffin wax were mixed together by a certain ratio to simulate lung nodules of 10 mm and 5 mm in diameter with the CT values ranging from -10 to 50 HU. Conventional-dose scan (240 mA, 140 kV) and low-dose scan of three different levels (43 mA, 140 kV; 50 mA, 120 kV; 75 mA, 80 kV) together with three different pitches (1.0, 1.5, and 2.0) were performed. The images of the simulated nodules were combined with the CT images of a normal adult's upper, middle, and inferior lung. Three radiologists read the images and the number of the nodules they detected including both the real ones and the false-positive ones was calculated to investigate weather there was any difference among different doses, pitch groups, and different locations. Results: The detection rate of the 10 mm and 5 mm nodules was 100% and 89.6% respectively by the low-dose scan. There was no difference between low-dose and conventional-dose CT (χ 2 =0.6907, P>0.70). The detection rate of 5 mm nodules declined when large pitch was used. Conclusion: The detection rates of 10 mm and 5 mm nodules had no difference between low-dose CT and conventional-dose CT. As the pitch augmented, the detection rate for the nodules declined

  6. Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ferda, Jiri, E-mail: e-mail@fnplzen.cz [Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzen (Czech Republic); Ferdova, Eva; Mirka, Hynek; Baxa, Jan; Bednarova, Alena [Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzen (Czech Republic); Flohr, Thomas; Schmidt, Bernhard [Siemens Healthcare, Computed Tomography, 91301 Siemensstr. 1, Forchheim (Germany); Matejovic, Martin [1st Internal Department, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzen (Czech Republic); Kreuzberg, Boris [Radiodiagnostic Clinic, Charles University Teaching Hospital Plzen, Alej Svobody 80, 30640 Plzen (Czech Republic)

    2011-02-15

    Aim: The aim of the study is to present the feasibility of using dual-energy CT and the evaluation of iodine and air distribution in differentiation of pathological conditions. Material and method: We used the data of 50 CT examinations performed due to suspected pulmonary embolism with any pathological finding except consolidation of the parenchyma. The patients underwent CT angiography of the pulmonary arteries on a dual-source CT (DSCT), with the two tubes independently operated at 140 and 80 kV. By exploiting the dual-energy information, iodine distribution maps were obtained in addition to the conventional CT images which served as a marker of pulmonary perfusion. Minimum intensity projections (MinIP) were used as a marker of air content. Results: By comparing the iodine distribution maps and MinIP images, it was possible to differentiate between the following templates of lung parenchyma: A - normal iodine and air distribution; B - iodine content deficit with minimal or with no redistribution of air; C - reduced iodine content and increased content of air; D - deficit of iodine content and increased content of air; E - increased iodine content and normal content of air; F - increased iodine content and reduced content of air; G - reduced perfusion and reduced content of air. The type A (five cases) was typical for the pulmonary embolism with preserved normal conditions of perfusion and ventilation. Type B (18 cases) occurred in pulmonary embolism; type C was found in case of inflammation of small respiratory airways (five cases); emphysema was typical for type D (nine cases); increased perfusion was observed in the parenchyma preserved from emphysema or preserved from embolism in cases of emphysema or pulmonary embolism; type F occurred in pulmonary interstitial edema (four cases) both with pulmonary infection; finally type G was found in interstitial lung diseases (five cases). Conclusion: Imaging of the pulmonary circulation by means of dual-energy CT opens

  7. Dual-energy CT iodine maps as an alternative quantitative imaging biomarker to abdominal CT perfusion: determination of appropriate trigger delays for acquisition using bolus tracking.

    Science.gov (United States)

    Skornitzke, Stephan; Fritz, Franziska; Mayer, Philipp; Koell, Marco; Hansen, Jens; Pahn, Gregor; Hackert, Thilo; Kauczor, Hans-Ulrich; Stiller, Wolfram

    2018-05-01

    Quantitative evaluation of different bolus tracking trigger delays for acquisition of dual energy (DE) CT iodine maps as an alternative to CT perfusion. Prior to this retrospective analysis of prospectively acquired data, DECT perfusion sequences were dynamically acquired in 22 patients with pancreatic carcinoma using dual source CT at 80/140 kV p with tin filtration. After deformable motion-correction, perfusion maps of blood flow (BF) were calculated from 80 kV p image series of DECT, and iodine maps were calculated for each of the 34 DECT acquisitions per patient. BF and iodine concentrations were measured in healthy pancreatic tissue and carcinoma. To evaluate potential DECT acquisition triggered by bolus tracking, measured iodine concentrations from the 34 DECT acquisitions per patient corresponding to different trigger delays were assessed for correlation to BF and intergroup differences between tissue types depending on acquisition time. Average BF measured in healthy pancreatic tissue and carcinoma was 87.6 ± 28.4 and 38.6 ± 22.2 ml/100 ml min -1 , respectively. Correlation between iodine concentrations and BF was statistically significant for bolus tracking with trigger delay greater than 0 s (r max = 0.89; p alternative to CT perfusion measurements of BF. Advances in knowledge: After clinical validation, DECT iodine maps of pancreas acquired using bolus tracking with appropriate trigger delay as determined in this study could offer an alternative quantitative imaging biomarker providing functional information for tumor assessment at reduced patient radiation exposure compared to CT perfusion measurements of BF.

  8. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion.

    Science.gov (United States)

    Yang, Y X; Teo, S-K; Van Reeth, E; Tan, C H; Tham, I W K; Poh, C L

    2015-08-01

    Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors' proposed approach. A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  9. Has PET/CT a role in the characterization of indeterminate lung lesions on staging CT in colorectal cancer? A prospective study

    DEFF Research Database (Denmark)

    Jess, P.; Seiersen, M.; Ovesen, H.

    2014-01-01

    Purpose CT has been found superior to chest x-ray to detect lung malignances. However, indeterminate lung lesions (ILL) are found in 4-42% by using CT in staging colorectal cancer (CRC) patients. Our aim was to examine the frequency of ILL on staging CT and the rate of the ILL being malignant...... CT performed 6, 12, 18 and 24 months postoperatively. Results Twenty percent of the patients had ILL. Four of these patients (8.5%) had lung metastases detected median 9 months postoperatively, while 2 (4.3%) had other lung malignancies. One patient had TB. In patients with normal staging chest CT 10...... of the 185 patients (5.4%) developed lung metastases detected median 16 months postoperatively. This was significantly later than in patients with ILL (p lung metastases no significant difference was found between the groups (p = 0...

  10. Does Enhancement or Perfusion on Preprocedure CT Predict Outcomes After Embolization of Hepatocellular Carcinoma?

    Science.gov (United States)

    Borgheresi, Alessandra; Gonzalez-Aguirre, Adrian; Brown, Karen T; Getrajdman, George I; Erinjeri, Joseph P; Covey, Anne; Yarmohammadi, Hooman; Ziv, Etay; Sofocleous, Constantinos T; Boas, Franz Edward

    2018-03-27

    The objective of this study was to evaluate whether quantitative enhancement or perfusion measurements on preprocedure triphasic computed tomography (CT) can be used to predict response or overall survival after embolization of hepatocellular carcinoma. The institutional review board approved this retrospective review of 63 patients with hepatocellular carcinoma treated with particle embolization between March 2009 and December 2014. Quantitative enhancement and perfusion measurements were performed on the target tumor and the background liver on the triphasic CT performed before treatment. Microvascular invasion (MVI) and degree of differentiation were determined from a core biopsy specimen. Quantitative enhancement and perfusion values were then correlated with pathology (two-tailed t test), response to embolization on modified Response Evaluation Criteria In Solid Tumors (two-tailed t test), and overall survival after embolization (Cox proportional hazards model). Arterial enhancement did not predict immediate response or overall survival after embolization. The degree of differentiation or presence of MVI also did not predict immediate response or overall survival after embolization. However, high hepatic artery coefficient or low portal vein coefficient, both in the tumor (P = .011 and P = .004) and in the background liver (P = .015 and P = .009), were associated with worse survival. Hepatic artery coefficient, both in the tumor (P = .025) and in the background liver (P = .013), were independent predictors of survival in a multivariate model including the Child-Pugh score and the BCLC stage. Tumor and liver perfusion parameters estimated from preprocedure triphasic CT were predictive of survival after embolization. Arterial-phase enhancement and histology (degree of differentiation or MVI) did not predict immediate response or overall survival after particle embolization. Copyright © 2018 The Association of University Radiologists

  11. Whole-brain 320-detector row dynamic volume CT perfusion detected crossed cerebellar diaschisis after spontaneous intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Jun; Chen, Wei-jian; Wang, Mei-hao; Li, Jian-ce; Zhang, Qian; Xia, Neng-zhi; Yang, Yun-jun [Wenzhou Medical University, Department of Radiology, First Affiliated Hospital, Wenzhou (China); Wu, Gui-yun [Cleveland Clinics Foundation, Department of Nuclear Medicine, Imaging Institute, Cleveland, OH (United States); Cheng, Jing-liang; Zhang, Yong [Zhengzhou University, Department of Radiology, First Affiliated Hospital, Zhengzhou (China); Zhuge, Qichuan [Wenzhou Medical University, Department of Neurosurgery, First Affiliated Hospital, Wenzhou (China)

    2014-11-09

    The purpose of this study was to evaluate the value of 320-detector row CT used to detect crossed cerebellar diaschisis (CCD) in patients with unilateral supratentorial spontaneous intracerebral hemorrhage (SICH). We investigated 62 of 156 patients with unilateral supratentorial SICH using 320-detector row CT scanning. Regional cerebral blood flow (rCBF), cerebral blood volume (rCBV), mean transit time (rMTT), and time to peak (rTTP) levels were measured in different regions of interest (ROIs) that were manually outlined on computed tomography perfusion (CTP) for the cerebrum, including normal-appearing brain tissue that surrounded the perilesional low-density area (NA) and the perihematomal low-density area (PA) in all patients and the cerebellum (ipsilateral and contralateral) in CCD-positive patients. Of 62 cases, a total of 14 met the criteria for CCD due to cerebellar perfusion asymmetry on CTP maps. In the quantitative analysis, significant differences were found in the perfusion parameters between the contralateral and ipsilateral cerebellum in CCD-positive cases. No significant differences were found between the CCD-positive group and the CCD-negative group according to the hematoma volume, NIHSS scores, and cerebral perfusion abnormality (each P > 0.05). The correlation analysis of the degree of NA, PA perfusion abnormality, and the degree of CCD severity showed negative and significant linear correlations (R, -0.66∝-0.56; P < 0.05). 320-detector row CT is a robust and practicable method for the comprehensive primary imaging work-up of CCD in unilateral supratentorial SICH patients. (orig.)

  12. Whole-brain 320-detector row dynamic volume CT perfusion detected crossed cerebellar diaschisis after spontaneous intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Fu, Jun; Chen, Wei-jian; Wang, Mei-hao; Li, Jian-ce; Zhang, Qian; Xia, Neng-zhi; Yang, Yun-jun; Wu, Gui-yun; Cheng, Jing-liang; Zhang, Yong; Zhuge, Qichuan

    2015-01-01

    The purpose of this study was to evaluate the value of 320-detector row CT used to detect crossed cerebellar diaschisis (CCD) in patients with unilateral supratentorial spontaneous intracerebral hemorrhage (SICH). We investigated 62 of 156 patients with unilateral supratentorial SICH using 320-detector row CT scanning. Regional cerebral blood flow (rCBF), cerebral blood volume (rCBV), mean transit time (rMTT), and time to peak (rTTP) levels were measured in different regions of interest (ROIs) that were manually outlined on computed tomography perfusion (CTP) for the cerebrum, including normal-appearing brain tissue that surrounded the perilesional low-density area (NA) and the perihematomal low-density area (PA) in all patients and the cerebellum (ipsilateral and contralateral) in CCD-positive patients. Of 62 cases, a total of 14 met the criteria for CCD due to cerebellar perfusion asymmetry on CTP maps. In the quantitative analysis, significant differences were found in the perfusion parameters between the contralateral and ipsilateral cerebellum in CCD-positive cases. No significant differences were found between the CCD-positive group and the CCD-negative group according to the hematoma volume, NIHSS scores, and cerebral perfusion abnormality (each P > 0.05). The correlation analysis of the degree of NA, PA perfusion abnormality, and the degree of CCD severity showed negative and significant linear correlations (R, -0.66∝-0.56; P < 0.05). 320-detector row CT is a robust and practicable method for the comprehensive primary imaging work-up of CCD in unilateral supratentorial SICH patients. (orig.)

  13. First Danish experience with ex vivo lung perfusion of donor lungs before transplantation.

    Science.gov (United States)

    Henriksen, Ian Sune Iversen; Møller-Sørensen, Hasse; Møller, Christian Holdfold; Zemtsovski, Mikhail; Nilsson, Jens Christian; Seidelin, Casper Tobias; Perch, Michael; Iversen, Martin; Steinbrüchel, Daniel

    2014-03-01

    The number of lung transplantations is limited by a general lack of donor organs. Ex vivo lung perfusion (EVLP) is a novel method to optimise and evaluate marginal donor lungs prior to transplantation. We describe our experiences with EVLP in Denmark during the first year after its introduction. The study was conducted by prospective registration of donor offers and lung transplantations in Denmark from 1 May 2012 to 30 April 2013. Donor lungs without any contraindications were transplanted in the traditional manner. Taken for EVLP were donor lungs that were otherwise considered transplantable, but failed to meet the usual criteria due to possible contusions or because they were from donors with sepsis or unable to pass the oxygenation test. In the study period, seven of 33 Danish lung transplantations were made possible due to EVLP. One patient died of non-EVLP-related causes, but all other recipients were alive with normal graft function at the end of our registration period. All lungs showed an improved PaO2/FiO2 ratio from a median 23.1 kPa (8.8-38.9) within the donor to 58.8 kPa (34.9-76.5) (FiO2 = 1.0) after EVLP, which corresponds to a 155% improved oxygenation. The median time to extubation, time in intensive care unit and the admission period were 1, 7 and 39 days, respectively. In the first year after the introduction of EVLP in Denmark, seven pairs of donor lungs that previously would have been rejected have been transplanted as a result of their improved function. EVLP seems to be a safe way to increase the use of marginal donor lungs. no funding was granted for the present paper. not relevant.

  14. Hepatic perfusion disorders: a pictorial review of CT and MR imaging

    International Nuclear Information System (INIS)

    Yim, Nam Yeol; Jeong, Yong Yeon; Shin, Sang Soo; Song, Sang Gook; Lim, Hyo Soon; Heo, Suk Hee; Chang, Nam Kyu; Yoon, Woong; Kang, Heoung Keun; Lan, Shen Yu

    2005-01-01

    The liver has a unique dual blood supply through the portal vein and the hepatic artery. There are several communications between these two vessels under various conditions such as in hepatic tumors, trauma and liver cirrhosis, vascular compromise, among others. When vascular compromise occurs, this dual blood supply system can cause changes in the volume of blood flow in individual vessels or even in the direction of blood flow. With rapid image acquisition and increased resolution available in multislice CT and MR imaging, hepatic perfusion disorders are now more frequently encountered than in the past. Familiarity with imaging findings of these perfusion disorders will be helpful in characterizing focal hepatic lesions and will also help to avoid false positive diagnoses

  15. Hepatic perfusion disorders: a pictorial review of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Nam Yeol; Jeong, Yong Yeon; Shin, Sang Soo; Song, Sang Gook; Lim, Hyo Soon; Heo, Suk Hee; Chang, Nam Kyu; Yoon, Woong; Kang, Heoung Keun [Chonnam National University, Gwangju (Korea, Republic of); Lan, Shen Yu [Yan Bian Cancer Hospital, Peijing (China)

    2005-09-15

    The liver has a unique dual blood supply through the portal vein and the hepatic artery. There are several communications between these two vessels under various conditions such as in hepatic tumors, trauma and liver cirrhosis, vascular compromise, among others. When vascular compromise occurs, this dual blood supply system can cause changes in the volume of blood flow in individual vessels or even in the direction of blood flow. With rapid image acquisition and increased resolution available in multislice CT and MR imaging, hepatic perfusion disorders are now more frequently encountered than in the past. Familiarity with imaging findings of these perfusion disorders will be helpful in characterizing focal hepatic lesions and will also help to avoid false positive diagnoses.

  16. Ventilation and Perfusion Lung Scintigraphy of Allergen-Induced Airway Responses in Atopic Asthmatic Subjects

    Directory of Open Access Journals (Sweden)

    Krishnan Parameswaran

    2007-01-01

    Full Text Available BACKGROUND: Both ventilation (V and perfusion (Q of the lungs are altered in asthma, but their relationships with allergen-induced airway responses and gas exchange are not well described.

  17. Weight preserving image registration for monitoring disease progression in lung CT.

    Science.gov (United States)

    Gorbunova, Vladlena; Lol, Pechin; Ashraf, Haseem; Dirksen, Asger; Nielsen, Mads; de Bruijne, Marleen

    2008-01-01

    We present a new image registration based method for monitoring regional disease progression in longitudinal image studies of lung disease. A free-form image registration technique is used to match a baseline 3D CT lung scan onto a following scan. Areas with lower intensity in the following scan compared with intensities in the deformed baseline image indicate local loss of lung tissue that is associated with progression of emphysema. To account for differences in lung intensity owing to differences in the inspiration level in the two scans rather than disease progression, we propose to adjust the density of lung tissue with respect to local expansion or compression such that the total weight of the lungs is preserved during deformation. Our method provides a good estimation of regional destruction of lung tissue for subjects with a significant difference in inspiration level between CT scans and may result in a more sensitive measure of disease progression than standard quantitative CT measures.

  18. PET/CT for diagnostics and therapy stratification of lung cancer

    International Nuclear Information System (INIS)

    Kratochwil, C.; Haberkorn, U.; Giesel, F.L.

    2010-01-01

    With the introduction of positron emission tomography (PET) and more recently the hybrid systems PET/CT, the management of cancer patients in the treatment strategy has changed tremendously. The combination of PET with multidetector CT scanning enables the integration of metabolic and high resolution morphological image information. PET/CT is nowadays an established modality for tumor detection, characterization, staging and response monitoring. The increased installation of PET/CT systems worldwide and also the increased scientific publications underline the importance of this imaging modality. PET/CT is particular the imaging modality of choice in lung cancer staging and re-staging (T, N and M staging). The possible increased success of surgery in lung cancer patients and also the expected reduction in additional invasive diagnostics lead to benefits for both the individual patient and the healthcare system. In this review article PET and PET/CT is presented for diagnostic and therapeutic stratification in lung cancer. The fundamentals of glucose metabolism, staging, tumor recurrence and therapeutic monitoring are presented. (orig.) [de

  19. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  20. Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    International Nuclear Information System (INIS)

    Blomley, Martin J.K.; McBride, Alan; Mohammedtagi, Sima; Albrecht, Thomas; Harvey, Christopher J.; Jaeger, Rolf; Standfield, Nigel J.; Dawson, Peter

    1999-01-01

    Aim: To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measure renal perfusion, to produce colour renal perfusion maps and to predict surgical outcome in infrarenal aortic aneurysm assessment. Methods: We studied 21 patients being assessed for repair of infrarenal AAA. Prior to the spiral CT, a single level through the renal hili and aorta was scanned after the intravenous injection of 25 ml of contrast given at 10 ml/s. Ten 1 s duration scans were performed from 8 to 30 s after injection. Optimal timing for CT angiography can then be determined. Time-density curves were then drawn for both kidneys and aorta using regions of interest (ROIs) or pixel-by-pixel analysis. Renal cortical perfusion was measured using both ROI analysis and pseudocolour perfusion images. Following previous work, perfusion was calculated as the peak upslope of the tissue time density curve divided by peak aortic enhancement. Results: Cortical mean perfusion averaged 2.48 ml/min per ml (range 0.8-3.7 ml/min per ml n=34) and the values obtained agreed with literature expectations. Follow up in the 10 patients proceeding to AAA repair suggest low mean perfusion values and predict a raised postoperative creatinine (P<0.05) Conclusions: Additional functional data and imaging can be obtained from the initial timing scan of a CT study, without requiring a dedicated study

  1. CT imaging of myocardial perfusion and viability. Beyond structure and function

    Energy Technology Data Exchange (ETDEWEB)

    Schoepf, U. Joseph [Medical University of South Carolina, Charleston, SC (United States). Dept. of Radiology and Radiological Sciences; Bamberg, Fabian [Muenchen Univ. (Germany); Bastarrika, Gorka [Sunnybrook Health Sciences Centre, Toronto, ON (Canada). Cardiothoracic Imaging Division; Ruzsics, Balazs [Royal Liverpool and Broadgreen Univ., Liverpool (United Kingdom). Dept. of Cardiology; Vliegenthart, Rozemarijn (ed.) [University Medical Center Groningen (Netherlands). Center for Medical Imaging

    2014-06-01

    First publication to be devoted to the subject. Reviews an advanced, promising application in healthcare. Spans multiple medical disciplines. The rapid evolution in cardiac computed tomography during the past decade has improved spatial and temporal resolution to the extent that cardiac CT is now an accepted alternative for the non-invasive interrogation of the heart. Beyond the assessment of cardiac structure and ventricular function, recent research has identified yet another promising CT application for the comprehensive diagnosis of coronary heart disease, namely the assessment of myocardial perfusion and viability. In this book, the first to be devoted to this novel application of CT, leading experts from across the world present up-to-date information and consider future directions. After short sections outlining the state of the art in the traditional applications of CT to image structure and function, the full range of CT techniques that may be employed to evaluate the myocardial blood supply are discussed in detail. Similarly, diverse CT approaches for the assessment of myocardial viability are described, with careful consideration of the available experimental and clinical evidence and the role of quantitative imaging.

  2. Studies on diagnosis of lung emphysema by CT image using experimental models and clinical cases

    International Nuclear Information System (INIS)

    Nakatani, Seiki

    1998-01-01

    Since the detailed report between the degree of functional disorder in lung emphysema and the analysis of CT image is quite unknown, the present study was attempted to produce the experimental model of lung emphysema with various stages by the administration of papain to the focal lobe in canine lung. Using this model or clinical lung emphysema, the relationship between the degree of destruction of alveolar walls, clinical pulmonary functions and CT images was investigated. CT scan was performed at the level of 50% vital capacity in both experimental models and clinical subjects by using spirometric gating CT. CT density histogram was obtained from CT image which was produced by using the developed software for this purpose. Densitometric parameters, such as mean CT value, %LAA, the peak in the histogram and 5% tile were selected from CT image. Papain solution of 5 mg/kg body weight was cumulatively administered to the left lower lobe in canine lung, resulting in the destruction of lung alveolar walls in parallel to the increasing dosage of papain. There was a significant correlation between not only the increasing dosage of papain, but also %FEV 1.0 and CT densitometric parameters, indicating that the histological changes of alveolar walls and the lung function in lung emphysema could be estimated by analysis of CT image. These experimental and clinical studies suggest that the analysis of CT image can reflect the pathophysiological changes in the lung and be useful for precise clinical diagnosis of lung emphysema. (author)

  3. Diagnosis of malignant pleural effusion and lung cancer with CT

    International Nuclear Information System (INIS)

    Jakimovska, S.; Jakimovska, M.; Jovanovska, S.; Ilieva, S.

    2012-01-01

    Full text: Introduction: A pleural effusion is defined as an abnormal amount of fluid in the space between the layers of tissue (the pleura) that line the lungs. If cancer cells are present in this fluid (pleural cavity) it is called a malignant cancerous pleural effusion. Many benign and malignant disease can cause pleural effusion.The new onset of pleural effusion may herald the presence of a previously undiagnosed malignancy, or more typically, complicate the course of a known lung tumor. Malignant pleural effusions can lead lead to an initial diagnosis of lung cancer in patients.and it was the first symptom of lung cancer. Pleural deposits of tumor cause pleuritic pain. Purpose of this presentation is to show the role of CT in diagnosis of malignant pleural effusion and lung cancer. Material and methods: CT examinations of chest were made to 138 patients for 1 year (1/6/2011- 1/6/2012) with Siemens Somatom Emotion 16 CT Scanner. Patients were at age of 30 -81 years, 93 of them are male and 45 are female. Results: 56 (40.5%) of the patients had pleural effusion. From this group 21 37.5% had malignant pleural effusion and lung cancer. 17 (81%) of them are male, and 4 (19%) are female. 9 (43%) diagnosed lung cancer for first time. Conclusion: Pleural effusion more commonly occur in patient with advanced-stage tumor who frequently have metastases to other organs and long-term survival is uncommon in this group. CT diagnosed malignant pleural effusion and lung cancer and help to choice treatment for these patients

  4. Lung Dose Calculation With SPECT/CT for {sup 90}Yittrium Radioembolization of Liver Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Naichang, E-mail: yun@ccf.org [Department of Radiation Oncology, Cleveland Clinic, Cleveland, OH (United States); Srinivas, Shaym M.; DiFilippo, Frank P.; Shrikanthan, Sankaran [Department of Nuclear Medicine, Cleveland Clinic, Cleveland, OH (United States); Levitin, Abraham; McLennan, Gordon; Spain, James [Department of Interventional Radiology, Cleveland Clinic, Cleveland, OH (United States); Xia, Ping; Wilkinson, Allan [Department of Radiation Oncology, Cleveland Clinic, Cleveland, OH (United States)

    2013-03-01

    Purpose: To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ({sup 99m}Tc-MAA) single photon emission CT (SPECT)/CT for {sup 90}Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Methods and Materials: Images of 71 patients who had SPECT/CT and PS images of {sup 99m}Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. Results: The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. Conclusions: A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on {sup 99m}Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended.

  5. Lung dose calculation with SPECT/CT for ⁹⁰Yittrium radioembolization of liver cancer.

    Science.gov (United States)

    Yu, Naichang; Srinivas, Shaym M; Difilippo, Frank P; Shrikanthan, Sankaran; Levitin, Abraham; McLennan, Gordon; Spain, James; Xia, Ping; Wilkinson, Allan

    2013-03-01

    To propose a new method to estimate lung mean dose (LMD) using technetium-99m labeled macroaggregated albumin ((99m)Tc-MAA) single photon emission CT (SPECT)/CT for (90)Yttrium radioembolization of liver tumors and to compare the LMD estimated using SPECT/CT with clinical estimates of LMD using planar gamma scintigraphy (PS). Images of 71 patients who had SPECT/CT and PS images of (99m)Tc-MAA acquired before TheraSphere radioembolization of liver cancer were analyzed retrospectively. LMD was calculated from the PS-based lung shunt assuming a lung mass of 1 kg and 50 Gy per GBq of injected activity shunted to the lung. For the SPECT/CT-based estimate, the LMD was calculated with the activity concentration and lung volume derived from SPECT/CT. The effect of attenuation correction and the patient's breathing on the calculated LMD was studied with the SPECT/CT. With these effects correctly taken into account in a more rigorous fashion, we compared the LMD calculated with SPECT/CT with the LMD calculated with PS. The mean dose to the central region of the lung leads to a more accurate estimate of LMD. Inclusion of the lung region around the diaphragm in the calculation leads to an overestimate of LMD due to the misregistration of the liver activity to the lung from the patient's breathing. LMD calculated based on PS is a poor predictor of the actual LMD. For the subpopulation with large lung shunt, the mean overestimation from the PS method for the lung shunt was 170%. A new method of calculating the LMD for TheraSphere and SIR-Spheres radioembolization of liver cancer based on (99m)Tc-MAA SPECT/CT is presented. The new method provides a more accurate estimate of radiation risk to the lungs. For patients with a large lung shunt calculated from PS, a recalculation of LMD based on SPECT/CT is recommended. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. CT staging of lung cancer: the role of artificial pneumothorax

    International Nuclear Information System (INIS)

    Lee, Jin Seong; Im, Jung Gi; Han, Man Chung

    1991-01-01

    To determine the role of artificially induced pneumothorax in the evaluation of the chest wall and mediastinal invasion in patients with peripheral bronchogenic carcinoma. CT scans of 22 patients obtained after induced pneumothorax were evaluated. All patients had peripheral lung mass abutting the pleura on a routine CT scan. Room air of 200-400ml was introduced through intrathoracic negative pressure initially, followed by pressure injection through the 18 gauge long bevelled needle under fluoroscopic control. Conclusively, CT with artificial pneumothorax added more information than conventional CT in the evaluation of the chest wall or mediastinal invasion by lung cancer without notable risk

  7. Fusion of CT coronary angiography and whole-heart dynamic 3D cardiac MR perfusion: building a framework for comprehensive cardiac imaging.

    Science.gov (United States)

    von Spiczak, Jochen; Manka, Robert; Gotschy, Alexander; Oebel, Sabrina; Kozerke, Sebastian; Hamada, Sandra; Alkadhi, Hatem

    2018-04-01

    The purpose of this work was to develop a framework for 3D fusion of CT coronary angiography (CTCA) and whole-heart dynamic 3D cardiac magnetic resonance perfusion (3D-CMR-Perf) image data-correlating coronary artery stenoses to stress-induced myocardial perfusion deficits for the assessment of coronary artery disease (CAD). Twenty-three patients who underwent CTCA and 3D-CMR-Perf for various indications were included retrospectively. For CTCA, image quality and coronary diameter stenoses > 50% were documented. For 3D-CMR-Perf, image quality and stress-induced perfusion deficits were noted. A software framework was developed to allow for 3D image fusion of both datasets. Computation steps included: (1) fully automated segmentation of coronary arteries and heart contours from CT; (2) manual segmentation of the left ventricle in 3D-CMR-Perf images; (3) semi-automatic co-registration of CT/CMR datasets; (4) projection of the 3D-CMR-Perf values on the CT left ventricle. 3D fusion analysis was compared to separate inspection of CTCA and 3D-CMR-Perf data. CT and CMR scans resulted in an image quality being rated as good to excellent (mean scores 3.5 ± 0.5 and 3.7 ± 0.4, respectively, scale 1-4). 3D-fusion was feasible in all 23 patients, and perfusion deficits could be correlated to culprit coronary lesions in all but one case (22/23 = 96%). Compared to separate analysis of CT and CMR data, coronary supply territories of 3D-CMR-Perf perfusion deficits were refined in two cases (2/23 = 9%), and the relevance of stenoses in CTCA was re-judged in four cases (4/23 = 17%). In conclusion, 3D fusion of CTCA/3D-CMR-Perf facilitates anatomic correlation of coronary lesions and stress-induced myocardial perfusion deficits thereby helping to refine diagnostic assessment of CAD.

  8. Unilateral absence of lung perfusion resulting from endarteritis of the pulmonary artery

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Turini, T.L.

    This case shows endarteritis of left pulmonary artery in the angiographic study with absent perfusion of the left lung in the MAA 131 I scintigraphy. Considerations are made conderning the presumable diagnosis of infection by 'toxocara canis' larval form. The literature review don't point out a similar case. (author) [pt

  9. Lung Perfusion SPECT: Application in a Patient With Tetralogy of Fallot and Suspected Pulmonary Thromboemboli

    International Nuclear Information System (INIS)

    Ranji Amjad, Mina; Abbasi, Mehrshad; Farzanehfar, Saeed

    2015-01-01

    A 22-year-old woman presented with acute left-sided pleuritic chest pain and dyspnea 6 days after surgery for revision of the stenotic central aortopulmonary shunt. She had a history of tetralogy of Fallot (TOF), pulmonary valve stenosis, ventricular septal defect and major aortopulmonary collateral artery. Her Waterston shunt was placed when she was 5 years old and stented and re-dilated after stenosis. Acute pulmonary thromboemboli (PTE) was suspected and pulmonary perfusion scan was performed with 4 mCi 99m Technetium labeled macroaggregated albumin. The left lung was globally hypoperfused with evident uptake in the brain, renal parenchyma and thyroid. SPECT images revealed a segmental wedge-shaped peripheral defect in the posterior segment of the left upper lobe. The scan was interpreted as acute/chronic PTE or vascular abnormality. CT angiography excluded PTE; nevertheless the patient was treated with a therapeutic dose of heparin changed to warfarin and was discharged with improvement of the symptoms. Pulmonary artery angiography was not performed

  10. 4D CT and lung cancer surgical resectability: a technical innovation

    International Nuclear Information System (INIS)

    Troupis, John M.; Pasricha, Sundeep S.; Narayanan, Harish; Rybicki, Frank J.

    2014-01-01

    A 74-year-old man presents with a left upper lobe lung adenocarcinoma, which demonstrated a wide base intimately with the aortic arch. We utilised 4D CT technique with a wide field of view CT unit to preoperatively determine likely surgical resectability. We propose that 4D CT may be of use in further investigating lung cancer with likely invasion of adjacent structures.

  11. Evaluation of patients undergoing lung volume reduction surgery: Ancillary information available from computed tomography

    International Nuclear Information System (INIS)

    Cleverley, Joanne R.; Desai, Sujal R.; Wells, Athol U.; Koyama, Hiroshi; Eastick, Sian; Schmidt, Maria A.; Charrier, Clare L.; Gatehouse, Peter D.; Goldstraw, Peter; Pepper, John R.; Geddes, Duncan M.; Hansell, David M.

    2000-01-01

    AIM: A number of imaging techniques have been used for the pre-operative assessment of patients for lung volume reduction surgery (LVRS). We evaluated whether data currently acquired from perfusion scintigrams and cine MR of the diaphragm are obtainable from high resolution CT (HRCT) of the thorax. MATERIALS AND METHODS: Thirty patients taking part in a randomized controlled trial of LVRS against maximal medical therapy were evaluated. HRCT examinations (n= 30) were scored for (i) the extent and distribution of emphysema; (ii) the extent of normal pulmonary vasculature; and (iii) diaphragmatic contour, apparent defects and herniation. On scintigraphy, (n28), perfusion of the lower thirds of both lungs, as a proportion of total lung perfusion (LZ/T PERF ), was expressed as a percentage of predicted values (derived from 10 normal control subjects). On cine MR (n= 25) hemidiaphragmatic excursion and coordination were recorded. RESULTS: Extensive emphysema was present on HRCT (60% ± 13.2%). There was strong correlation between the extent of normal pulmonary vasculature on HRCT and on perfusion scanning (r s = 0.85, P< 0.00005). Hemidiaphragmatic incoordination on MR was weakly associated with hemidiaphragmatic eventration on HRCT (P0.04). CONCLUSION: The strong correlation between lung perfusion assessed by HRCT and lung perfusion on scintigraphy suggests that perfusion scintigraphy is superfluous in the pre-operative evaluation of patients with emphysema for LVRS. Cleverley, J.R. (2000)

  12. The value of perfusion CT in predicting the short-term response to synchronous radiochemotherapy for cervical squamous cancer

    International Nuclear Information System (INIS)

    Li, Xiang Sheng; Fan, Hong Xia; Zhu, Hong Xian; Song, Yun Long; Zhou, Chun Wu

    2012-01-01

    To determine the value of the perfusion parameters in predicting short-term tumour response to synchronous radiochemotherapy for cervical squamous carcinoma. Ninety-three patients with cervical squamous carcinoma later than stage IIB were included in this study. Perfusion CT was performed for all these patients who subsequently received the same synchronous radiochemotherapy. The patients were divided into responders and non-responders according to short-term response to treatment. Baseline perfusion parameters of the two groups were compared. The perfusion parameters that might affect treatment effect were analysed by using a multivariate multi-regression analysis. The responders group had higher baseline permeability-surface area product (PS) and blood volume (BV) values than the non-responders group (P 0.05). At multivariate multi-regression analysis, BV, PS and tumour size were significant factors in the prediction of treatment effect. Small tumours usually had high PS and BV values, and thus had a good treatment response. Perfusion CT can provide some helpful information for the prediction of the short-term effect. Synchronous radiochemotherapy may be more effective in cervical squamous carcinoma with higher baseline PS and BV. (orig.)

  13. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  14. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Y. X.; Van Reeth, E.; Poh, C. L., E-mail: clpoh@ntu.edu.sg [School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637459 (Singapore); Teo, S.-K. [Institute of High Performance Computing, Agency for Science, Technology and Research, Singapore 138632 (Singapore); Tan, C. H. [Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore 308433 (Singapore); Tham, I. W. K. [Department of Radiation Oncology, National University Cancer Institute, Singapore 119082 (Singapore)

    2015-08-15

    Purpose: Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors’ proposed approach. Methods: A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. Results: The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors’ proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. Conclusions: The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  15. Quantitative measurement of lung density with x-ray CT and positron CT, (2). Diseased subjects

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kengo; Ito, Masatoshi; Kubota, Kazuo

    1985-05-01

    Lung density was quantitatively measured on six diseased patients with X-ray CT (XCT) and Positron CT(PCT). The findings are as follows: In the silicosis, extravascular lung density was found to be remarkably increased compared to normals (0.29gcm/sup 3/), but blood volume was in normal range. In the post-irradiated lung cancers, extravascular lung density increased in the irradiated sites compared to the non-irradiated opposite sites, and blood volume varied in each case. In a patient with chronic heart failure, blood volume decreased (0.11mlcm/sup 3/) with increased extravascular lung density (0.23gcm/sup 3/). In the chronic obstructive pulmonary disease, both extravascular lung density and blood volume decreased (0.11gcm/sup 3/ and 0.10mlcm/sup 3/ respectively). Lung density measured with XCT was constantly lower than that with PCT in all cases. But changes in the values of lung density measured, correlated well with each other. In conclusion, the method presented here may clarify the etiology of the diffuse pulmonary diseases, and be used to differentiate and grade the diseases.

  16. Influence of lung CT changes in chronic obstructive pulmonary disease (COPD on the human lung microbiome.

    Directory of Open Access Journals (Sweden)

    Marion Engel

    Full Text Available Changes in microbial community composition in the lung of patients suffering from moderate to severe COPD have been well documented. However, knowledge about specific microbiome structures in the human lung associated with CT defined abnormalities is limited.Bacterial community composition derived from brush samples from lungs of 16 patients suffering from different CT defined subtypes of COPD and 9 healthy subjects was analyzed using a cultivation independent barcoding approach applying 454-pyrosequencing of 16S rRNA gene fragment amplicons.We could show that bacterial community composition in patients with changes in CT (either airway or emphysema type changes, designated as severe subtypes was different from community composition in lungs of patients without visible changes in CT as well as from healthy subjects (designated as mild COPD subtype and control group (PC1, Padj = 0.002. Higher abundance of Prevotella in samples from patients with mild COPD subtype and from controls and of Streptococcus in the severe subtype cases mainly contributed to the separation of bacterial communities of subjects. No significant effects of treatment with inhaled glucocorticoids on bacterial community composition were detected within COPD cases with and without abnormalities in CT in PCoA. Co-occurrence analysis suggests the presence of networks of co-occurring bacteria. Four communities of positively correlated bacteria were revealed. The microbial communities can clearly be distinguished by their associations with the CT defined disease phenotype.Our findings indicate that CT detectable structural changes in the lung of COPD patients, which we termed severe subtypes, are associated with alterations in bacterial communities, which may induce further changes in the interaction between microbes and host cells. This might result in a changed interplay with the host immune system.

  17. Influence of lung CT changes in chronic obstructive pulmonary disease (COPD) on the human lung microbiome.

    Science.gov (United States)

    Engel, Marion; Endesfelder, David; Schloter-Hai, Brigitte; Kublik, Susanne; Granitsiotis, Michael S; Boschetto, Piera; Stendardo, Mariarita; Barta, Imre; Dome, Balazs; Deleuze, Jean-François; Boland, Anne; Müller-Quernheim, Joachim; Prasse, Antje; Welte, Tobias; Hohlfeld, Jens; Subramanian, Deepak; Parr, David; Gut, Ivo Glynne; Greulich, Timm; Koczulla, Andreas Rembert; Nowinski, Adam; Gorecka, Dorota; Singh, Dave; Gupta, Sumit; Brightling, Christopher E; Hoffmann, Harald; Frankenberger, Marion; Hofer, Thomas P; Burggraf, Dorothe; Heiss-Neumann, Marion; Ziegler-Heitbrock, Loems; Schloter, Michael; Zu Castell, Wolfgang

    2017-01-01

    Changes in microbial community composition in the lung of patients suffering from moderate to severe COPD have been well documented. However, knowledge about specific microbiome structures in the human lung associated with CT defined abnormalities is limited. Bacterial community composition derived from brush samples from lungs of 16 patients suffering from different CT defined subtypes of COPD and 9 healthy subjects was analyzed using a cultivation independent barcoding approach applying 454-pyrosequencing of 16S rRNA gene fragment amplicons. We could show that bacterial community composition in patients with changes in CT (either airway or emphysema type changes, designated as severe subtypes) was different from community composition in lungs of patients without visible changes in CT as well as from healthy subjects (designated as mild COPD subtype and control group) (PC1, Padj = 0.002). Higher abundance of Prevotella in samples from patients with mild COPD subtype and from controls and of Streptococcus in the severe subtype cases mainly contributed to the separation of bacterial communities of subjects. No significant effects of treatment with inhaled glucocorticoids on bacterial community composition were detected within COPD cases with and without abnormalities in CT in PCoA. Co-occurrence analysis suggests the presence of networks of co-occurring bacteria. Four communities of positively correlated bacteria were revealed. The microbial communities can clearly be distinguished by their associations with the CT defined disease phenotype. Our findings indicate that CT detectable structural changes in the lung of COPD patients, which we termed severe subtypes, are associated with alterations in bacterial communities, which may induce further changes in the interaction between microbes and host cells. This might result in a changed interplay with the host immune system.

  18. Measurement of total lung capacity : a comparison of spiral CT and spirometry

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Park, Kyung Ju; Lee, Eh Hyung; Yune, Heun Young; Suh, Jung Ho; Choe, Kyu Ok; Lim, Tae Hwan; Chung, In Hyuk

    1996-01-01

    To determine the potential of spiral CT as a functional imaging modality of the lung aside from its proven value in morphological depiction. Spiral CT scan was performed in ten normal female and nine normal male adults (mean age: 39, height: 163 cm, weight: 62 kg ) after single full breath-holding. Three dimensional lung images were reconstructed(minimal threshold value: -1,000HU, maximal threshold values: -150, 250, -350, -450 HU) to obtain total lung volume(TLV) on a histogram. Total lung volume measured by spiral CT was compared with TLV obtained by spirometry. Mean TLV measured by spirometry was 5.62L and TLV measured by CT at maximal threshold values of -150, -250, -350, and -450 HU was 5.53, 5.33, 5.15, and 4.98L, respectively. Mean absolute differences between the modalities of 0.17L(3%), 0.32L(5.6%), 0.48L(8.5%), 0.65L(11.5%) were statistically significant(p<0.001). Linear regression coefficients between the modalities were 0.99, 0.97, 095, and 0.94 and no statistically significant differences in accuracy of threshold levels in the estimation of lung volume(r=0.99, standard error=0.034L in all) were seen. TLV measured by spiral CT closely approximated that measured by spirometry. Spiral CT may be useful as a means of evaluating lung function

  19. Scintigraphic and MR perfusion imaging in preoperative evaluation for lung volume reduction surgery. Pilot study results

    International Nuclear Information System (INIS)

    Johkoh, Takeshi; Mueller, N.L.; Kavanagh, P.V

    2000-01-01

    To compare MR perfusion imaging with perfusion scintigraphy in the evaluation of patients with pulmonary emphysema being considered for lung volume reduction surgery. Six patients with pulmonary emphysema and two normal individuals were evaluated by MR perfusion imaging, perfusion scintigraphy, and selective bilateral pulmonary angiography. MR images were obtained with an enhanced fast gradient recalled echo with three-dimensional Fourier transformation technique (efgre 3D) (6.3/1.3; flip angle, 30 deg C; field of view, 45-48 cm; matrix, 256 x 160). The presence or absence of perfusion defects in each segment was evaluated by two independent observers. Using angiography as the gold standard, the sensitivity, specificity, and accuracy of MR perfusion imaging in detecting focal perfusion abnormalities were 90%, 87%, and 89%, respectively, while those of perfusion scintigraphy were 71%, 76%, and 71%, respectively. The diagnostic accuracy of MR perfusion imaging was significantly higher than that of scintigraphy (p<0.001, McNemar test). There was good agreement between two observers for MR perfusion imaging (kappa statistic, 0.66) and only moderate agreement for perfusion scintigraphy (kappa statistic, 0.51). MR perfusion imaging is superior to perfusion scintigraphy in the evaluation of pulmonary parenchymal perfusion in patients with pulmonary emphysema. (author)

  20. CTA-enhanced perfusion CT: an original method to perform ultra-low-dose CTA-enhanced perfusion CT

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Elizabeth; Wintermark, Max [University of Virginia, Department of Radiology, Neuroradiology Division, Charlottesville, VA (United States)

    2014-11-15

    Utilizing CT angiography enhances image quality in PCT, thereby permitting acquisition at ultra-low dose. Dynamic CT acquisitions were obtained at 80 kVp with decreasing tube current-time product [milliamperes x seconds (mAs)] in patients suspected of ischemic stroke, with concurrent CTA of the cervical and intracranial arteries. By utilizing fast Fourier transformation, high spatial frequencies of CTA were combined with low spatial frequencies of PCT to create a virtual PCT dataset. The real and virtual PCT datasets with decreasing mAs were compared by assessing contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and noise and PCT values and by visual inspection of PCT parametric maps. Virtual PCT attained CNR and SNR three- to sevenfold superior to real PCT and noise reduction by a factor of 4-6 (p < 0.05). At 20 mAs, virtual PCT achieved diagnostic parametric maps, while the quality of real PCT maps was inadequate. At 10 mAs, both real and virtual PCT maps were nondiagnostic. Virtual PCT (but not real PCT) maps regained diagnostic quality at 10 mAs by applying 40 % adaptive statistical iterative reconstruction (ASIR) and improved further with 80 % ASIR. Our new method of creating virtual PCT by combining ultra-low-dose PCT with CTA information yields diagnostic perfusion parametric maps from PCT acquired at 20 or 10 mAs with 80 % ASIR. Effective dose is approximately 0.20 mSv, equivalent to two chest radiographs. (orig.)

  1. Correlation of pulmonary perfusion volume analysis with pulmonary function in emphysema

    International Nuclear Information System (INIS)

    Kaneta, Tomohiro; Yamazaki, Tetsuro; Takai, Yoshihiro; Takahashi, Shoki; Yamada, Shogo; Maruoka, Shin; Abe, Yoetsu

    2000-01-01

    Pulmonary perfusion single photon emission tomography with 99m Tc MAA was performed on 13 pulmonary emphysema patients and 6 controls. We calculated perfusion volume with lower 10%, 20%, 30%, 40% and 50% of the highest counts/boxels in the lung cut-off. And perfusion index (PI) was defined as follows; PI=((A% cut-off volume)-(B% cut-off volume))/(A% cut-off volume); A and B take 10 to 50, A 1 , FEV 1 %, VC, VC%, FVC, FVC%, PaO 2 and PaCO 2 ) was examined. There were significant correlation between every PI and FEV 1 or FEV 1 % (p 1 (r=0.680) and FEV 1 % (r=0.830). And the PI showed an increasing tendency along with the rise of the emphysema severity. The PI may have the clinical utility of the evaluation of pulmonary function. Moreover, we showed the lung CT painted the area where the uptake counts/boxels was more than 10% and less than 40% of the highest counts/boxels. This makes it easy to understand the severe emphysematous area. (author)

  2. Weight preserving image registration for monitoring disease progression in lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Lo, Pechin Chien Pau; Haseem, Ashraf

    2008-01-01

    We present a new image registration based method for monitoring regional disease progression in longitudinal image studies of lung disease. A free-form image registration technique is used to match a baseline 3D CT lung scan onto a following scan. Areas with lower intensity in the following scan...... the density of lung tissue with respect to local expansion or compression such that the total weight of the lungs is preserved during deformation. Our method provides a good estimation of regional destruction of lung tissue for subjects with a significant difference in inspiration level between CT scans...

  3. Lung cancer screening with low-dose CT

    International Nuclear Information System (INIS)

    Diederich, S.; Wormanns, D.; Heindel, W.

    2003-01-01

    Screening for lung cancer is hoped to reduce mortality from this common tumour, which is characterised by a dismal overall survival, relatively well defined risk groups (mainly heavy cigarette smokers and workers exposed to asbestos) and a lack of early symptoms. In the past studies using sputum cytology and chest radiography have failed to demonstrate any reduction in lung cancer mortality through screening. One of the reasons is probably the relatively poor sensitivity of both these tests in early tumours. Low radiation dose computed tomography (CT) has been shown to have a much higher sensitivity for small pulmonary nodules, which are believed to be the most common presentation of early lung cancer. As, however, small pulmonary nodules are common and most are not malignant, non-invasive diagnostic algorithms are required to correctly classify the detected lesions and avoid invasive procedures in benign nodules. Nodule density, size and the demonstration of growth at follow-up have been shown to be useful in this respect and may in the future be supplemented by contrast-enhanced CT and positron emission tomography. Based on these diagnostic algorithms preliminary studies of low-dose CT in heavy smokers have demonstrated a high proportion of asymptomatic, early, resectable cancers with good survival. As, however, several biases could explain these findings in the absence of the ultimate goal of cancer screening, i.e. mortality reduction, most researchers believe that randomised controlled trials including several 10000 subjects are required to demonstrate a possible mortality reduction. Only then general recommendations to screen individuals at risk of lung cancer with low-dose CT should be made. It can be hoped that international cooperation will succeed in providing results as early as possible

  4. A method for smoothing segmented lung boundary in chest CT images

    Science.gov (United States)

    Yim, Yeny; Hong, Helen

    2007-03-01

    To segment low density lung regions in chest CT images, most of methods use the difference in gray-level value of pixels. However, radiodense pulmonary vessels and pleural nodules that contact with the surrounding anatomy are often excluded from the segmentation result. To smooth lung boundary segmented by gray-level processing in chest CT images, we propose a new method using scan line search. Our method consists of three main steps. First, lung boundary is extracted by our automatic segmentation method. Second, segmented lung contour is smoothed in each axial CT slice. We propose a scan line search to track the points on lung contour and find rapidly changing curvature efficiently. Finally, to provide consistent appearance between lung contours in adjacent axial slices, 2D closing in coronal plane is applied within pre-defined subvolume. Our method has been applied for performance evaluation with the aspects of visual inspection, accuracy and processing time. The results of our method show that the smoothness of lung contour was considerably increased by compensating for pulmonary vessels and pleural nodules.

  5. Dynamic CT Perfusion Imaging for the Detection of Crossed Cerebellar Diaschisis in Acute Ischemic Stroke

    International Nuclear Information System (INIS)

    Jeon, Young Wook; Kim, Seo Hyun; Lee, Ji Young; Whang, Kum; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub; Brain Reserch Group

    2012-01-01

    Although the detection of crossed cerebellar diaschisis (CCD) by means of different imaging modalities is well described, little is known about its diagnosis by computed tomography perfusion (CTP) imaging. We investigated the detection rate of CCD by CTP imaging and the factors related to CCD on CTP images in patients with acute ischemic stroke. CT perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time-to-peak (TTP) obtained from 81 consecutive patients affected by an acute ischemic stroke were retrospectively reviewed. Whole-brain perfusion maps were obtained with a multichannel CT scanner using the toggling-table technique. The criteria for CCD was a unilateral supratentorial ischemic lesion and an accompanying decrease in perfusion of the contralateral cerebellar hemisphere on the basis of CTP maps by visual inspection without a set threshold. Maps were quantitatively analyzed in CCD positive cases. The criteria for CCD were fulfilled in 25 of the 81 cases (31%). Detection rates per CTP map were as follows: MTT (31%) > TTP (21%) > CBF (9%) > CBV (6%). Supratentorial ischemic volume, degree of perfusion reduction, and infratentorial asymmetry index correlated strongly (R, 0.555-0.870) and significantly (p < 0.05) with each other in CCD-positive cases. It is possible to detect CCD on all four of the CTP-based maps. Of these maps, MTT is most sensitive in detecting CCD. Our data indicate that CTP imaging is a valid tool for the diagnosis of CCD in patients affected by an acute hemispheric stroke.

  6. CT evaluation of cavitary lung lesions: focused on lung cancer, tuberculosis and abscess

    International Nuclear Information System (INIS)

    Lee, Young Rahn; Kim, Myung Gyu; Kang, Eun Young; Suh, Won Hyuck

    1992-01-01

    Differential diagnosis of cavitary lung lesions is frequently problematic. We studied 35 patients with cavitary lung lesions, consisting of lung cancer (17 patients), pulmonary tuberculosis (11 patients), and lung abscess (7 patients). We analysed CT scans in terms of irregularities of the cavity wall, maximum wall thickness, the presence of air-fluid level, location of the cavity within the mass, number of cavities within the mass, size of the cavity and the presence of calcification within the mass. Cancer cavity showed irregular inner (100%) and outer margins (100%), and thick wall (mean, 1.94 cm), eccentrical location (94%) and multiplicity within a mass (38%). Tuberculous cavity showed smooth inner (56%) and irregular outer margins (75%), thin wall (mean 0.96 cm), central location (62%), and multiplicity in one patient (36%). Abscess cavity showed irregular inner (57%) and outer margins (91%), relatively thin wall (mean 1.0 cm), central location (57%), and air-fluid level (86%). CT scan could differentiate malignant lesions from benign condition such as tuberculosis and lung abscess by observing characteristics of the cavities

  7. CT evaluation of cavitary lung lesions: focused on lung cancer, tuberculosis and abscess

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Rahn; Kim, Myung Gyu; Kang, Eun Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1992-11-15

    Differential diagnosis of cavitary lung lesions is frequently problematic. We studied 35 patients with cavitary lung lesions, consisting of lung cancer (17 patients), pulmonary tuberculosis (11 patients), and lung abscess (7 patients). We analysed CT scans in terms of irregularities of the cavity wall, maximum wall thickness, the presence of air-fluid level, location of the cavity within the mass, number of cavities within the mass, size of the cavity and the presence of calcification within the mass. Cancer cavity showed irregular inner (100%) and outer margins (100%), and thick wall (mean, 1.94 cm), eccentrical location (94%) and multiplicity within a mass (38%). Tuberculous cavity showed smooth inner (56%) and irregular outer margins (75%), thin wall (mean 0.96 cm), central location (62%), and multiplicity in one patient (36%). Abscess cavity showed irregular inner (57%) and outer margins (91%), relatively thin wall (mean 1.0 cm), central location (57%), and air-fluid level (86%). CT scan could differentiate malignant lesions from benign condition such as tuberculosis and lung abscess by observing characteristics of the cavities.

  8. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  9. Ex vivo lung perfusion to improve donor lung function and increase the number of organs available for transplantation.

    Science.gov (United States)

    Valenza, Franco; Rosso, Lorenzo; Coppola, Silvia; Froio, Sara; Palleschi, Alessandro; Tosi, Davide; Mendogni, Paolo; Salice, Valentina; Ruggeri, Giulia M; Fumagalli, Jacopo; Villa, Alessandro; Nosotti, Mario; Santambrogio, Luigi; Gattinoni, Luciano

    2014-06-01

    This paper describes the initial clinical experience of ex vivo lung perfusion (EVLP) at the Fondazione Ca' Granda in Milan between January 2011 and May 2013. EVLP was considered if donor PaO2 /FiO2 was below 300 mmHg or if lung function was doubtful. Donors with massive lung contusion, aspiration, purulent secretions, pneumonia, or sepsis were excluded. EVLP was run with a low-flow, open atrium and low hematocrit technique. Thirty-five lung transplants from brain death donors were performed, seven of which after EVLP. EVLP donors were older (54 ± 9 years vs. 40 ± 15 years, EVLP versus Standard, P donor organs and resulted in successful transplants with lungs that would have otherwise been rejected (ClinicalTrials.gov number: NCT01967953). © 2014 The Authors. Transplant International published by John Wiley & Sons Ltd on behalf of Steunstichting ESOT.

  10. Elevation of the correlation between cerebral blood volume and permeability surface from CT perfusion images with glioma grade

    International Nuclear Information System (INIS)

    Ding Bei; Ling Huawei; Zhang Huan; Song Qi; Dong Haipeng; Chen Kemin

    2007-01-01

    Objective: To evaluate the correlation between cerebral blood volume and permeability surface by using multislice CT perfusion imaging with glioma grade. Methods: Ninteen patients with gliomas underwent conventional MR and multislice CT perfusion imaging preoperatively. These patients were divided into low grade and high grade groups which were correspond to WHO II grade gliomas and WHO III or IV grade gliomas respectively. CT data were transferred to on-line working station and processed to obtain time-signal curves, color perfusion maps and calculated perfusion parameters, including cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTF) and permeability surfaces (PS) in tumoral parenchyma. Kruskal-Wallis test and correlation of CBV and PS was assessed by using SPSS 11.0 software. Results: The median of CBV and PS in low-grade and high-grade glioma were 2.7, 6.5 ml/100 g; 0.389, 12.810 ml·100 g -1 ·min -1 respectively, corresponding t value were 12.907 13.500 with P<0.05. Pearson correlations between CBV and PS were as follows: in low-grade group, r=-0.058, in high-grade group, r=0.648. Conclusion: Both CBV and PS have obvious correlation with glioma grade. The correlation between CBV and PS in low-grade glioma was weaker, probably because of the focal high vascularity in oligodendroglioma. (authors)

  11. Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion.

    Science.gov (United States)

    Skornitzke, S; Fritz, F; Klauss, M; Pahn, G; Hansen, J; Hirsch, J; Grenacher, L; Kauczor, H-U; Stiller, W

    2015-02-01

    To compare six different scenarios for correcting for breathing motion in abdominal dual-energy CT (DECT) perfusion measurements. Rigid [RRComm(80 kVp)] and non-rigid [NRComm(80 kVp)] registration of commercially available CT perfusion software, custom non-rigid registration [NRCustom(80 kVp], demons algorithm) and a control group [CG(80 kVp)] without motion correction were evaluated using 80 kVp images. Additionally, NRCustom was applied to dual-energy (DE)-blended [NRCustom(DE)] and virtual non-contrast [NRCustom(VNC)] images, yielding six evaluated scenarios. After motion correction, perfusion maps were calculated using a combined maximum slope/Patlak model. For qualitative evaluation, three blinded radiologists independently rated motion correction quality and resulting perfusion maps on a four-point scale (4 = best, 1 = worst). For quantitative evaluation, relative changes in metric values, R(2) and residuals of perfusion model fits were calculated. For motion-corrected images, mean ratings differed significantly [NRCustom(80 kVp) and NRCustom(DE), 3.3; NRComm(80 kVp), 3.1; NRCustom(VNC), 2.9; RRComm(80 kVp), 2.7; CG(80 kVp), 2.7; all p VNC), 22.8%; RRComm(80 kVp), 0.6%; CG(80 kVp), 0%]. Regarding perfusion maps, NRCustom(80 kVp) and NRCustom(DE) were rated highest [NRCustom(80 kVp), 3.1; NRCustom(DE), 3.0; NRComm(80 kVp), 2.8; NRCustom(VNC), 2.6; CG(80 kVp), 2.5; RRComm(80 kVp), 2.4] and had significantly higher R(2) and lower residuals. Correlation between qualitative and quantitative evaluation was low to moderate. Non-rigid motion correction improves spatial alignment of the target region and fit of CT perfusion models. Using DE-blended and DE-VNC images for deformable registration offers no significant improvement. Non-rigid algorithms improve the quality of abdominal CT perfusion measurements but do not benefit from DECT post processing.

  12. Differential diagnosis between pulmonary tuberculosis and lung abscess by contrast enhanced CT

    International Nuclear Information System (INIS)

    Kanauchi, Tetsu; Hoshi, Toshiko; Konno, Miyuki; Hando, Yumiko

    2001-01-01

    The contrast enhanced CT findings in 14 patients with active tuberculosis and 26 patients with lung abscess were retrospectively analyzed. Reflecting the difference of pathogenesis between tuberculosis and abscess, the findings are widely different. The findings suggesting pulmonary tuberculosis rather than lung abscess were as follows; multiple and irregular necrotic areas, positive CT angiogram sign, no marginal enhancement surrounding necrosis. Contrast enhanced CT may help to distinguish pulmonary tuberculosis from lung abscess, especially in cases of caseous pneumonia showing broad consolidations or mass-like shadows. (author)

  13. MRI and CT lung biomarkers: Towards an in vivo understanding of lung biomechanics.

    Science.gov (United States)

    Young, Heather M; Eddy, Rachel L; Parraga, Grace

    2017-09-29

    The biomechanical properties of the lung are necessarily dependent on its structure and function, both of which are complex and change over time and space. This makes in vivo evaluation of lung biomechanics and a deep understanding of lung biomarkers, very challenging. In patients and animal models of lung disease, in vivo evaluations of lung structure and function are typically made at the mouth and include spirometry, multiple-breath gas washout tests and the forced oscillation technique. These techniques, and the biomarkers they provide, incorporate the properties of the whole organ system including the parenchyma, large and small airways, mouth, diaphragm and intercostal muscles. Unfortunately, these well-established measurements mask regional differences, limiting their ability to probe the lung's gross and micro-biomechanical properties which vary widely throughout the organ and its subcompartments. Pulmonary imaging has the advantage in providing regional, non-invasive measurements of healthy and diseased lung, in vivo. Here we summarize well-established and emerging lung imaging tools and biomarkers and how they may be used to generate lung biomechanical measurements. We review well-established and emerging lung anatomical, microstructural and functional imaging biomarkers generated using synchrotron x-ray tomographic-microscopy (SRXTM), micro-x-ray computed-tomography (micro-CT), clinical CT as well as magnetic resonance imaging (MRI). Pulmonary imaging provides measurements of lung structure, function and biomechanics with high spatial and temporal resolution. Imaging biomarkers that reflect the biomechanical properties of the lung are now being validated to provide a deeper understanding of the lung that cannot be achieved using measurements made at the mouth. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  15. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  16. Histogram Analysis of CT Perfusion of Hepatocellular Carcinoma for Predicting Response to Transarterial Radioembolization: Value of Tumor Heterogeneity Assessment.

    Science.gov (United States)

    Reiner, Caecilia S; Gordic, Sonja; Puippe, Gilbert; Morsbach, Fabian; Wurnig, Moritz; Schaefer, Niklaus; Veit-Haibach, Patrick; Pfammatter, Thomas; Alkadhi, Hatem

    2016-03-01

    To evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE). Sixteen patients (15 male; mean age 65 years; age range 47-80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters' ability to discriminate responders from non-responders. According to mRECIST, 8 patients (50%) were responders and 8 (50%) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min(-1) 100 mL(-1)); p 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min(-1) 100 mL(-1), therapy response could be predicted with a sensitivity of 88% (7/8) and specificity of 75% (6/8). Voxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.

  17. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    International Nuclear Information System (INIS)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio; Takeuchi, Yoshihito.

    1998-01-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  18. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio [Aichi Cancer Center, Nagoya (Japan); Takeuchi, Yoshihito

    1998-02-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  19. Characterization of the relation between CT technical parameters and accuracy of quantification of lung attenuation on quantitative chest CT.

    Science.gov (United States)

    Trotta, Brian M; Stolin, Alexander V; Williams, Mark B; Gay, Spencer B; Brody, Alan S; Altes, Talissa A

    2007-06-01

    The purpose of this study was to assess the compromise between CT technical parameters and the accuracy of CT quantification of lung attenuation. Materials that simulate water (0 H), healthy lung (-650 H), borderline emphysematous lung (-820 H), and severely emphysematous lung (-1,000 H) were placed at both the base and the apex of the lung of an anthropomorphic phantom and outside the phantom. Transaxial CT images through the samples were obtained while the effective tube current was varied from 440 to 10 mAs, kilovoltage from 140 to 80 kVp, and slice thickness from 0.625 to 10 mm. Mean +/- SD attenuation within the samples and the standard quantitative chest CT measurements, the percentage of pixels with attenuation less than -910 H and 15th percentile of attenuation, were computed. Outside the phantom, variations in CT parameters produced less than 2.0% error in all measurements. Within the anthropomorphic phantom at 30 mAs, error in measurements was much larger, ranging from zero to 200%. Below approximately 80 mAs, mean attenuation became increasingly biased. The effects were most pronounced at the apex of the lungs. Mean attenuation of the borderline emphysematous sample of apex decreased 55 H as the tube current was decreased from 300 to 30 mAs. Both the 15th percentile of attenuation and percentage of pixels with less than -910 H attenuation were more sensitive to variations in effective tube current than was mean attenuation. For example, the -820 H sample should have 0% of pixels less than -910 H, which was true at 400 mA. At 30 mA in the lung apex, however, the measurement was highly inaccurate, 51% of pixels being below this value. Decreased kilovoltage and slice thickness had analogous, but lesser, effects. The accuracy of quantitative chest CT is determined by the CT acquisition parameters. There can be significant decreases in accuracy at less than 80 mAs for thin slices in an anthropomorphic phantom, the most pronounced effects occurring in the lung

  20. Quantitative evaluation of emphysematous changes in the lung by computed tomography (CT)

    International Nuclear Information System (INIS)

    Kitahara, Yoshinari; Hirayama, Takanobu; Hiratsuka, Toshihiko; Tanaka, Yasushi; Takamoto, Masahiro; Ishibashi, Tsuneo; Shinoda, Atsushi

    1987-01-01

    The present studies were undertaken to quantitatively evaluate emphysematous changes in the lung by CT scan. CT scans were made at inspiration and expiration at three levels (base, mid thorax and apex). Low density lesion ratio (LL %) was measured as the proportion of the area under -950 Housfield Unit in each lung field at expiration. Each value of LL % was determined in 6 lung fields (both lung fields at three levels). The LL % was calculated from the mean of these six values. The results suggest that LL % of the emphysematous lungs shows significant elevation of the values compared with those of normal lungs and lungs with bronchial asthma. (author)

  1. Effects of isoproterenol on distribution of perfusion in embolized dog lungs

    International Nuclear Information System (INIS)

    Shepard, J.W. Jr.; Hauer, D.; Sgroi, V.; Moser, K.M.

    1979-01-01

    In 19 mechanically ventilated, anesthetized dogs, autologous venous thrombi were formed in the inferior vena cava and subsequently released. Serial perfusion lung scintigrams revealed the postembolic distribution of pulmonary blood flow before, during, and after the infusion of isoproterenol at 2.2 μg/min. Isoproterenol failed to restore perfusion to embolically occluded regions. When reperfusion occurred it was attributable to clot resolution. Gas exchange and hemodynamic measurements obtained in seven thromboembolized animals showed no scan evidence of reperfusion during the isoproterenol infusion. After embolization, cardiac output increased from 1.7 to 2.6 liter/min (p 2 from 38.0 to 45.3 mm Hg (p 2 to 50.7 mm Hg, along with a decrease in pulmonary vascular resistance from the postembolic mean of 448 to 246 dynes.sec.cm -5 (p < 0.05). Perfusion defects following acute pulmonary thromboembolization are not altered by the infusion of the potent pulmonary vasodilator, isoproterenol. Infusion of this drug following thromboembolization may have potential therapeutic benefit by reducing pulmonary vascular resistance, increasing cardiac output, and elevating the mixed-venous oxygen tension

  2. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  3. Lung scintigraphy in differential diagnosis of peripheral lung cancer and community-acquired pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Krivonogov, Nikolay G., E-mail: kng@cardio-tomsk.ru [Research Institute of Cardiology, Kievskaya Street 111a, Tomsk, 634012 (Russian Federation); Efimova, Nataliya Y., E-mail: efimova@cardio-tomsk.ru; Zavadovsky, Konstantin W.; Lishmanov, Yuri B. [Research Institute of Cardiology, Kievskaya Street 111a, Tomsk, 634012 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.

  4. Lung scintigraphy in differential diagnosis of peripheral lung cancer and community-acquired pneumonia

    Science.gov (United States)

    Krivonogov, Nikolay G.; Efimova, Nataliya Y.; Zavadovsky, Konstantin W.; Lishmanov, Yuri B.

    2016-08-01

    Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.

  5. Comparative reading support system for lung cancer CT screening

    International Nuclear Information System (INIS)

    Kubo, Mitsuru; Saita, Shinsuke; Kawata, Yoshiki; Niki, Noboru; Suzuki, Hidenobu; Ohmatsu, Hironobu; Eguchi, Kenji; Kaneko, Masahiro; Moriyama, Noriyuki

    2010-01-01

    The comparative reading is performed using current and past images of the same case obtained from lung cancer CT screening. The result of this is useful for the early detection of lung cancer. Our paper describes the efficiency improvement of comparative reading using 10 mm slice thickness CT images by developing the system consists of slice registration method, pulmonary nodule registration method, and quantitative evaluation method of pulmonary nodule's degree of change. The proposed system is applied to CT images scanned for 1107 times of 85 cases with 198 pulmonary nodules and is evaluated by comparing it with the reading result of the doctors. We show the effectiveness of the system. (author)

  6. Respiratory lung motion analysis using a nonlinear motion correction technique for respiratory-gated lung perfusion SPECT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Haneishi, Hideaki; Iwanaga, Hideyuki; Suga, Kazuyoshi

    2007-01-01

    This study evaluated the respiratory motion of lungs using a nonlinear motion correction technique for respiratory-gated single photon emission computed tomography (SPECT) images. The motion correction technique corrects the respiratory motion of the lungs nonlinearly between two-phase images obtained by respiratory-gated SPECT. The displacement vectors resulting from respiration can be computed at every location of the lungs. Respiratory lung motion analysis is carried out by calculating the mean value of the body axis component of the displacement vector in each of the 12 small regions into which the lungs were divided. In order to enable inter-patient comparison, the 12 mean values were normalized by the length of the lung region along the direction of the body axis. This method was applied to 25 Technetium (Tc)-99m-macroaggregated albumin (MAA) perfusion SPECT images, and motion analysis results were compared with the diagnostic results. It was confirmed that the respiratory lung motion reflects the ventilation function. A statistically significant difference in the amount of the respiratory lung motion was observed between the obstructive pulmonary diseases and other conditions, based on an unpaired Student's t test (P<0.0001). A difference in the motion between normal lungs and lungs with a ventilation obstruction was detected by the proposed method. This method is effective for evaluating obstructive pulmonary diseases such as pulmonary emphysema and diffuse panbronchiolitis. (author)

  7. The Danish randomized lung cancer CT screening trial

    DEFF Research Database (Denmark)

    Pedersen, Jesper H; Ashraf, Haseem; Dirksen, Asger

    2009-01-01

    INTRODUCTION: Lung cancer screening with low dose computed tomography (CT) has not yet been evaluated in randomized clinical trials, although several are underway. METHODS: In The Danish Lung Cancer Screening Trial, 4104 smokers and previous smokers from 2004 to 2006 were randomized to either...... lung cancer. Ten of these had stage I disease. Eleven of 17 lung cancers at baseline were treated surgically, eight of these by video assisted thoracic surgery resection. CONCLUSIONS: Screening may facilitate minimal invasive treatment and can be performed with a relatively low rate of false......-positive screen results compared with previous studies on lung cancer screening....

  8. Non-contrast-enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRI.

    Science.gov (United States)

    Bauman, Grzegorz; Puderbach, Michael; Deimling, Michael; Jellus, Vladimir; Chefd'hotel, Christophe; Dinkel, Julien; Hintze, Christian; Kauczor, Hans-Ulrich; Schad, Lothar R

    2009-09-01

    Assessment of regional lung perfusion and ventilation has significant clinical value for the diagnosis and follow-up of pulmonary diseases. In this work a new method of non-contrast-enhanced functional lung MRI (not dependent on intravenous or inhalative contrast agents) is proposed. A two-dimensional (2D) true fast imaging with steady precession (TrueFISP) pulse sequence (TR/TE = 1.9 ms/0.8 ms, acquisition time [TA] = 112 ms/image) was implemented on a 1.5T whole-body MR scanner. The imaging protocol comprised sets of 198 lung images acquired with an imaging rate of 3.33 images/s in coronal and sagittal view. No electrocardiogram (ECG) or respiratory triggering was used. A nonrigid image registration algorithm was applied to compensate for respiratory motion. Rapid data acquisition allowed observing intensity changes in corresponding lung areas with respect to the cardiac and respiratory frequencies. After a Fourier analysis along the time domain, two spectral lines corresponding to both frequencies were used to calculate the perfusion- and ventilation-weighted images. The described method was applied in preliminary studies on volunteers and patients showing clinical relevance to obtain non-contrast-enhanced perfusion and ventilation data.

  9. WE-B-207-00: CT Lung Cancer Screening Part 1

    International Nuclear Information System (INIS)

    2015-01-01

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Under the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan

  10. WE-B-207-00: CT Lung Cancer Screening Part 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Under the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan

  11. Automated interpretation of PET/CT images in patients with lung cancer

    DEFF Research Database (Denmark)

    Gutte, Henrik; Jakobsson, David; Olofsson, Fredrik

    2007-01-01

    cancer. METHODS: A total of 87 patients who underwent PET/CT examinations due to suspected lung cancer comprised the training group. The test group consisted of PET/CT images from 49 patients suspected with lung cancer. The consensus interpretations by two experienced physicians were used as the 'gold...... method measured as the area under the receiver operating characteristic curve, was 0.97 in the test group, with an accuracy of 92%. The sensitivity was 86% at a specificity of 100%. CONCLUSIONS: A completely automated method using artificial neural networks can be used to detect lung cancer......PURPOSE: To develop a completely automated method based on image processing techniques and artificial neural networks for the interpretation of combined [(18)F]fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) images for the diagnosis and staging of lung...

  12. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    International Nuclear Information System (INIS)

    Lim, Kun Young; Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi; Seo, Joon Beom

    2006-01-01

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images (ρ < 0.01). Agreement was fair between two observers (κ = 0.38, ρ < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens

  13. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kun Young [National Cancer Center, Goyang (Korea, Republic of); Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi [Seoul National University Hospital and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Seo, Joon Beom [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2006-05-15

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images ({rho} < 0.01). Agreement was fair between two observers ({kappa} = 0.38, {rho} < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens.

  14. CT-guided percutaneous conformal cryoablation for lung carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yueyong, Xiao; Bin, Wu; Xiao, Zhang; Hongjun, Li; Da, Yu; Jie, Li; Jun, Li [Department of Radiology, PLA General Hospital, Beijing (China)

    2010-02-15

    Objective: To investigate the safety, efficacy and feasibility of CT-guided percutaneous conformal cryoablation for lung cancer. Methods: The inclusion criteria were: (1) Poor respiratory function and aged patients who can not bear the thoracic surgical operation. (2) Peripheral lung cancer involving the pleura and chest wall which can not be resected. (3) Residual tumor after other comprehensive treatment. (4) Focal lung cancer but the patient refused surgical resection. The exclusion criteria were: (1) Multifocal lesions. (2) Lesion close to mediastinum with possible risk of vessel injury. (3) Severe impairment of pulmonary functions, the maximum voluntary ventilation is less than 39%. (4) Repeated cough or dyspnea, can not cooperate with the procedure. (5) Poor systemic conditions, cachexia or bleeding. Totally, 76 lung carcinoma lesions on 66 patients were treated by CT-guided percutaneous conformal cryoablation using 17 G cryoprobes. The maximum diameters of the tumors ranged from 1.5 cm to 1.6 cm. For the tumors with the maximum diameter less than 3.0 cm, they were treated by double-needle clamping cryoablation. For those with the maximum diameter between 3.0 and 5.0 cm, they were treated by multiple-needle conformal cryoablation. For those with the maximum diameter larger than 5.0 cm, they were treated with multiple-needle conformal cyroablation, with the needle distance less than 1.5 cm. All the patients were followed-up 6 to 24 months after the procedure using contrast-enhanced CT to evaluate the tumor size and enhancement. Results: For 18 cases with the maximum diameters less than 3.0 cm, CT scan during the procedure showed that the frozen areas extended beyond the edge of the lesions more than 1.0 cm, the lesion attenuated, narrow-band-like encircled translucency around the lesions and 'target sign' with ground-glass density of the peripheral lung tissue. There was no enhancement during the first 1 st, 3 rd month follow-up, only fibrosis scar in 6 th

  15. CT-guided percutaneous conformal cryoablation for lung carcinoma

    International Nuclear Information System (INIS)

    Xiao Yueyong; Wu Bin; Zhang Xiao; Li Hongjun; Yu Da; Li Jie; Li Jun

    2010-01-01

    Objective: To investigate the safety, efficacy and feasibility of CT-guided percutaneous conformal cryoablation for lung cancer. Methods: The inclusion criteria were: (1) Poor respiratory function and aged patients who can not bear the thoracic surgical operation. (2) Peripheral lung cancer involving the pleura and chest wall which can not be resected. (3) Residual tumor after other comprehensive treatment. (4) Focal lung cancer but the patient refused surgical resection. The exclusion criteria were: (1) Multifocal lesions. (2) Lesion close to mediastinum with possible risk of vessel injury. (3) Severe impairment of pulmonary functions, the maximum voluntary ventilation is less than 39%. (4) Repeated cough or dyspnea, can not cooperate with the procedure. (5) Poor systemic conditions, cachexia or bleeding. Totally, 76 lung carcinoma lesions on 66 patients were treated by CT-guided percutaneous conformal cryoablation using 17 G cryoprobes. The maximum diameters of the tumors ranged from 1.5 cm to 1.6 cm. For the tumors with the maximum diameter less than 3.0 cm, they were treated by double-needle clamping cryoablation. For those with the maximum diameter between 3.0 and 5.0 cm, they were treated by multiple-needle conformal cryoablation. For those with the maximum diameter larger than 5.0 cm, they were treated with multiple-needle conformal cyroablation, with the needle distance less than 1.5 cm. All the patients were followed-up 6 to 24 months after the procedure using contrast-enhanced CT to evaluate the tumor size and enhancement. Results: For 18 cases with the maximum diameters less than 3.0 cm, CT scan during the procedure showed that the frozen areas extended beyond the edge of the lesions more than 1.0 cm, the lesion attenuated, narrow-band-like encircled translucency around the lesions and 'target sign' with ground-glass density of the peripheral lung tissue. There was no enhancement during the first 1 st, 3 rd month follow-up, only fibrosis scar in 6 th

  16. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  17. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  18. Brain Perfusion Changes in Intracerebral Hemorrhage

    International Nuclear Information System (INIS)

    Mititelu, R.; Mazilu, C.; Ghita, S.; Rimbu, A.; Marinescu, G.; Codorean, I.; Bajenaru, O.

    2006-01-01

    Full text: Purpose: Despite the latest advances in medical treatment and neuro critical care, patients suffering spontaneous intracerebral hemorrhage (SICH) still have a very poor prognosis, with a greater mortality and larger neurological deficits at the survivors than for ischemic stroke. Many authors have shown that there are many mechanisms involved in the pathology of SICH: edema, ischemia, inflammation, apoptosis. All of these factors are affecting brain tissue surrounding hematoma and are responsible of the progressive neurological deterioration; most of these damages are not revealed by anatomical imaging techniques. The aim of our study was to asses the role of brain perfusion SPECT in demonstrating perfusion changes in SICH patients. Method: 17 SICH pts were studied. All pts underwent same day CT and brain SPECT with 99mTcHMPAO, 24h-5d from onset of stroke. Results: 14/17 pts showed a larger perfusion defect than expected after CT. In 2 pts hematoma diameter was comparable on CT and SPECT; 1pt had quasinormal aspect of SPECT study. In pts with larger defects, SPECT revealed a large cold spot with similar size compared with CT, and a surrounding hypo perfused area. 6/17 pts revealed cortical hyper perfusion adjacent to hypo perfused area and corresponding to a normal-appearing brain tissue on CT. In 3 pts we found crossed cerebellar diaskisis.In 2 pts we found cortical hypo perfused area in the contralateral cortex, with normal appearing brain tissue on CT. Conclusions: Brain perfusion SPECT revealed different types of perfusion changes in the brain tissue surrounding hematoma. These areas contain viable brain tissue that may be a target for future ne uroprotective strategies. Further studies are definitely required to demonstrate prognostic significance of these changes, but we can conclude that brain perfusion SPECT can play an important role in SICH, by early demonstrating functional changes responsible of clinical deterioration, thus allowing prompt

  19. Study of regional lung ventilation and perfusion by xenon 133

    International Nuclear Information System (INIS)

    Lombard, Yves.

    1976-01-01

    The present work consists of a regional lung exploration after injection of xenon 133, dissolved in physiological serum, followed a few minutes later by that of 99m Tc-labelled serumalbumin microspheres. The aim is three fold: first of all to study perfusion and ventilation by xenon 133, next to compare the results obtained after xenon 133 and 99 m Tc-labelled microsphere injection, lastly to establish the value of the technique and its routine application. This examination has not solved all problems of lung exploration by xenon 133. For example we deliberately kept to intraveinous injection of the gas dissolved in physiological serum, leaving aside the breathing test. Xenon 133 scintigraphy in our opinion will not tend to replace 99m Tc-labelled microsphere scintigraphy, which has irreplaceable morphological qualities, but will serve as an excellent complement. The basic advantage of xenon 133 is the regional ventilation estimate it provides allowing any anomaly of the lung parenchyma to be located immediately or conversely the functional value of the healthy lung to be established with a view to a surgical removal of a diseased zone [fr

  20. Activation of rho is involved in the mechanism of hydrogen-peroxide-induced lung edema in isolated perfused rabbit lung.

    Science.gov (United States)

    Chiba, Y; Ishii, Y; Kitamura, S; Sugiyama, Y

    2001-09-01

    Acute lung injury is attributed primarily to increased vascular permeability caused by reactive oxygen species derived from neutrophils, such as hydrogen peroxide (H2O2). Increased permeability is accompanied by the contraction and cytoskeleton reorganization of endothelial cells, resulting in intercellular gap formation. The Rho family of Ras-like GTPases is implicated in the regulation of the cytoskeleton and cell contraction. We examined the role of Rho in H2O2-induced pulmonary edema with the use of isolated perfused rabbit lungs. To our knowledge, this is the first study to examine the role of Rho in increased vascular permeability induced by H2O2 in perfused lungs. Vascular permeability was evaluated on the basis of the capillary filtration coefficient (Kfc, ml/min/cm H2O/100 g). We found that H2O2 (300 microM) increased lung weight, Kfc, and pulmonary capillary pressure. These effects of H2O2 were abolished by treatment with Y-27632 (50 microM), an inhibitor of the Rho effector p160 ROCK. In contrast, the muscular relaxant papaverine inhibited the H2O2-induced rise in pulmonary capillary pressure, but did not suppress the increases in lung weight and Kfc. These findings indicate that H2O2 causes pulmonary edema by elevating hydrostatic pressure and increasing vascular permeability. Y-27632 inhibited the formation of pulmonary edema by blocking both of these H2O2-induced effects. Our results suggest that Rho-related pathways have a part in the mechanism of H2O2-induced pulmonary edema. Copyright 2001 Academic Press.

  1. Emphysema quantification and lung volumetry in chest X-ray equivalent ultralow dose CT - Intra-individual comparison with standard dose CT.

    Science.gov (United States)

    Messerli, Michael; Ottilinger, Thorsten; Warschkow, René; Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Bauer, Ralf W

    2017-06-01

    To determine whether ultralow dose chest CT with tin filtration can be used for emphysema quantification and lung volumetry and to assess differences in emphysema measurements and lung volume between standard dose and ultralow dose CT scans using advanced modeled iterative reconstruction (ADMIRE). 84 consecutive patients from a prospective, IRB-approved single-center study were included and underwent clinically indicated standard dose chest CT (1.7±0.6mSv) and additional single-energy ultralow dose CT (0.14±0.01mSv) at 100kV and fixed tube current at 70mAs with tin filtration in the same session. Forty of the 84 patients (48%) had no emphysema, 44 (52%) had emphysema. One radiologist performed fully automated software-based pulmonary emphysema quantification and lung volumetry of standard and ultralow dose CT with different levels of ADMIRE. Friedman test and Wilcoxon rank sum test were used for multiple comparison of emphysema and lung volume. Lung volumes were compared using the concordance correlation coefficient. The median low-attenuation areas (LAA) using filtered back projection (FBP) in standard dose was 4.4% and decreased to 2.6%, 2.1% and 1.8% using ADMIRE 3, 4, and 5, respectively. The median values of LAA in ultralow dose CT were 5.7%, 4.1% and 2.4% for ADMIRE 3, 4, and 5, respectively. There was no statistically significant difference between LAA in standard dose CT using FBP and ultralow dose using ADMIRE 4 (p=0.358) as well as in standard dose CT using ADMIRE 3 and ultralow dose using ADMIRE 5 (p=0.966). In comparison with standard dose FBP the concordance correlation coefficients of lung volumetry were 1.000, 0.999, and 0.999 for ADMIRE 3, 4, and 5 in standard dose, and 0.972 for ADMIRE 3, 4 and 5 in ultralow dose CT. Ultralow dose CT at chest X-ray equivalent dose levels allows for lung volumetry as well as detection and quantification of emphysema. However, longitudinal emphysema analyses should be performed with the same scan protocol and

  2. PET/CT in therapy evaluation of patients with lung cancer

    DEFF Research Database (Denmark)

    Langer, Natasha Hemicke; Christensen, Tine Nøhr; Langer, Seppo W

    2014-01-01

    FDG-PET/CT is a well documented and widespread used imaging modality for the diagnosis and staging of patient with lung cancer. FDG-PET/CT is increasingly used for the assessment of treatment effects during and after chemotherapy. However, PET is not an accepted surrogate end-point for assessment...... of response rate in clinical trials. The aim of this review is to present current evidence on the use of PET in response evaluation of patients with lung cancer and to introduce the pearls and pitfalls of the PET-technology relating to response assessment. Based on this and relating to validation criteria......, including stable technology, standardization, reproducibility and broad availability, the review discusses why, despite numerous studies on response assessment indicating a possible role for FDG-PET/CT, PET still has no place in guidelines relating to response evaluation in lung cancer....

  3. High resolution CT of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Harumi (Kyoto Univ. (Japan). Faculty of Medicine)

    1991-02-01

    The emergence of computed tomography (CT) in the early 1970s has greatly contributed to diagnostic radiology. The brain was the first organ examined with CT, followed by the abdomen. For the chest, CT has also come into use shortly after the introduction in the examination of the thoracic cavity and mediastinum. CT techniques were, however, of limited significance in the evaluation of pulmonary diseases, especially diffuse pulmonary diseases. High-resolution CT (HRCT) has been introduced in clinical investigations of the lung field. This article is designed to present chest radiographic and conventional tomographic interpretations and to introduce findings of HRCT corresponding to the same shadows, with a summation of the significance of HRCT and issues of diagnostic imaging. Materials outlined are tuberculosis, pneumoconiosis, bronchopneumonia, mycoplasma pneumonia, lymphangitic carcinomatosis, sarcoidosis, diffuse panbronchiolitis, interstitial pneumonia, and pulmonary emphysema. Finally, an overview of basic investigations evolved from HRCT is given. (N.K.) 140 refs.

  4. CT myocardial perfusion imaging: current status and future perspectives.

    Science.gov (United States)

    Yang, Dong Hyun; Kim, Young-Hak

    2017-07-01

    Computed tomography myocardial perfusion (CTP) combined with coronary computed tomography angiography (CCTA) may constitute a "1-stop shop" for the noninvasive diagnosis of hemodynamically significant coronary stenosis during a single CT examination. CTP shows high diagnostic performance and provides incremental value over CCTA for the detection of hemodynamically significant coronary stenosis in patients with a high Agatston calcium score or coronary artery stents. Future studies should determine the optimal protocol and clinical value of CTP for guiding revascularization strategy and prognostication. In this article, we review the current status and future perspectives of CTP, focusing on technical considerations, clinical applications, and future research topics.

  5. CT diagnosis of pleural dissemination without pleural effusion in primary lung cancer

    International Nuclear Information System (INIS)

    Murayama, Sadayuki; Murakami, Junji; Yoshimitsu, Kengo; Torii, Yoshikuni; Masuda, Kouji; Ishida, Teruyoshi.

    1996-01-01

    We retrospectively reviewed the CT scans of 25 primary lung cancers with disseminated pleural nodules or minimal malignant pleural effusion that were not recognized preparatively. Special attention was devoted to abutting interlobar fissures, thick major fissures, and disseminated nodules on the chest wall, the diaphragm, and in the interlobar fissures. Among 10 primary tumors abutting interlobar fissures, nine (90%) had at least one of these findings. Among 15 primary lung tumors which did not abut interlobar fissures, four (27%) had at least one of these findings. We conclude that CT is a useful modality for detecting the pleural dissemination of primary lung cancers when primary lung cancers abut interlobar fissures even if no pleural effusion is detectable on CT. (author)

  6. Fractal analysis in radiological and nuclear medicine perfusion imaging: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Michallek, Florian; Dewey, Marc [Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Charite - Universitaetsmedizin Berlin, Medical School, Department of Radiology, Berlin (Germany)

    2014-01-15

    To provide an overview of recent research in fractal analysis of tissue perfusion imaging, using standard radiological and nuclear medicine imaging techniques including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and single-photon emission computed tomography (SPECT) and to discuss implications for different fields of application. A systematic review of fractal analysis for tissue perfusion imaging was performed by searching the databases MEDLINE (via PubMed), EMBASE (via Ovid) and ISI Web of Science. Thirty-seven eligible studies were identified. Fractal analysis was performed on perfusion imaging of tumours, lung, myocardium, kidney, skeletal muscle and cerebral diseases. Clinically, different aspects of tumour perfusion and cerebral diseases were successfully evaluated including detection and classification. In physiological settings, it was shown that perfusion under different conditions and in various organs can be properly described using fractal analysis. Fractal analysis is a suitable method for quantifying heterogeneity from radiological and nuclear medicine perfusion images under a variety of conditions and in different organs. Further research is required to exploit physiologically proven fractal behaviour in the clinical setting. (orig.)

  7. Fractal analysis in radiological and nuclear medicine perfusion imaging: a systematic review

    International Nuclear Information System (INIS)

    Michallek, Florian; Dewey, Marc

    2014-01-01

    To provide an overview of recent research in fractal analysis of tissue perfusion imaging, using standard radiological and nuclear medicine imaging techniques including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and single-photon emission computed tomography (SPECT) and to discuss implications for different fields of application. A systematic review of fractal analysis for tissue perfusion imaging was performed by searching the databases MEDLINE (via PubMed), EMBASE (via Ovid) and ISI Web of Science. Thirty-seven eligible studies were identified. Fractal analysis was performed on perfusion imaging of tumours, lung, myocardium, kidney, skeletal muscle and cerebral diseases. Clinically, different aspects of tumour perfusion and cerebral diseases were successfully evaluated including detection and classification. In physiological settings, it was shown that perfusion under different conditions and in various organs can be properly described using fractal analysis. Fractal analysis is a suitable method for quantifying heterogeneity from radiological and nuclear medicine perfusion images under a variety of conditions and in different organs. Further research is required to exploit physiologically proven fractal behaviour in the clinical setting. (orig.)

  8. Transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma located in the subphrenic region of liver

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    2000-01-01

    The purpose of this study is to evaluate the feasibility of transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma (HCC, 15 lesions) located in the subphrenic region and untreatable by ultrasonography-guided PEIT. The HCC was localized on Lipiodol CT image with a graduated grid system. We advanced a PEIT needle in a stepwise fashion, perpendicularly to the major axis of body through the lung with intermittent localization scans to position the tip of the needle in the lesion. Ethanol was injected with monitoring scans obtained after incremental volumes of injection, until perfusion was judged to be complete. A total of 20 CT-PEIT sessions were performed. The average number of needles passed from skin to liver in each CT-PEIT session was 2.7, the average volume of ethanol injected was 11.7 ml, and the average time required was 53.6 minutes. Complete perfusion of the lesion by ethanol was achieved in all lesions with only a single or double CT-PEIT procedure without severe complications. Local recurrence was detected in 3 to 15 followed up lesions for 14 months on average. In conclusion, transpulmonary CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC located in the subphrenic region. (author)

  9. Hepatic arterial perfusion increases in the early stage of severe acute pancreatitis patients: Evaluation by perfusion computed tomography

    International Nuclear Information System (INIS)

    Koyasu, Sho; Isoda, Hiroyoshi; Tsuji, Yoshihisa; Yamamoto, Hiroshi; Matsueda, Kazuhiro; Watanabe, Yuji; Chiba, Tsutomu; Togashi, Kaori

    2012-01-01

    Purpose: Although hepatic perfusion abnormalities have been reported in patients with acute pancreatitis, hepatic perfusion with severe acute pancreatitis (SAP) has not been quantitatively evaluated in humans. Therefore, we investigated hepatic perfusion in patients with SAP using perfusion CT. Materials and methods: Hepatic perfusion CT was performed in 67 patients with SAP within 3 days after symptom onset. The patients were diagnosed as having SAP according to the Atlanta criteria. Fifteen cases were established as a control group. Perfusion CT was obtained for 54 s beginning with a bolus injection of 40 ml of contrast agent (600–630 mgI/kg) at a flow rate of 4 ml/s. Perfusion data were analyzed by the dual-input maximum slope method to obtain hepatic arterial perfusion (HAP) and hepatic portal perfusion (HPP). Finally, we compared HAP and HPP in SAP patients with those in the control group, respectively. Results: Average HAP was significantly higher in SAP patients than in the control group (75.1 ± 38.0 vs. 38.2 ± 9.0 ml/min/100 ml; p < 0.001). There was no significant difference in average HPP between SAP patients and the control group (206.7 ± 54.9 vs. 204.4 ± 38.5 ml/min/100 ml; p = 0.92). Conclusion: Using quantitative analysis on perfusion CT, we first demonstrated an increase of HAP in the right hepatic lobe in SAP patients.

  10. Mass Preserving Registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Lo, Pechin Chien Pau; Loeve, Martin

    2009-01-01

    intensities due to differences in inspiration level, we propose to adjust the intensity of lung tissue according to the local expansion or compression. An image registration method without intensity adjustment is compared to the proposed method. Both approaches are evaluated on a set of 10 pairs of expiration...... and inspiration CT scans of children with cystic fibrosis lung disease. The proposed method with mass preserving adjustment results in significantly better alignment of the vessel trees. Analysis of local volume change for regions with trapped air compared to normally ventilated regions revealed larger...

  11. Cyclooxygenase-2-dependent bronchoconstriction in perfused rat lungs exposed to endotoxin.

    OpenAIRE

    Uhlig, S.; Nüsing, R.; von Bethmann, A.; Featherstone, R. L.; Klein, T.; Brasch, F.; Müller, K. M.; Ullrich, V.; Wendel, A.

    1996-01-01

    BACKGROUND: Lipopolysaccharides (LPS), widely used to study the mechanisms of gram-negative sepsis, increase airway resistance by constriction of terminal bronchioles. The role of the cyclooxygenase (COX) isoenzymes and their prostanoid metabolites in this process was studied. MATERIALS AND METHODS: Pulmonary resistance, the release of thromboxane (TX) and the expression of COX-2 mRNA were measured in isolated blood-free perfused rat lungs exposed to LPS. RESULTS: LPS induced the release of T...

  12. MRI of pulmonary perfusion; MRT der Lungenperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany); Risse, F.; Semmler, W. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Medizinische Physik in der Radiologie, Heidelberg (Germany); Schoenberg, S.O.; Reiser, M.F. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Kauczor, H.-U. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany)

    2006-04-15

    Lung perfusion is a crucial prerequisite for effective gas exchange. Quantification of pulmonary perfusion is important for diagnostic considerations and treatment planning in various diseases of the lungs. Besides disorders of pulmonary vessels such as acute pulmonary embolism and pulmonary hypertension, these also include diseases of the respiratory tract and lung tissue as well as pulmonary tumors. This contribution presents the possibilities and technical requirements of MRI for diagnostic work-up of pulmonary perfusion. (orig.) [German] Die Perfusion der Lunge ist eine entscheidende Voraussetzung fuer einen effektiven Gasaustausch. Die Bestimmung der Lungenperfusion ist bei verschiedenen Erkrankungen der Lunge fuer Diagnostik und Therapieplanung bedeutsam. Hierzu zaehlen neben Erkrankungen der Lungengefaesse wie akute Lungenembolie und pulmonale Hypertension ebenso Erkrankungen der Atemwege, des Lungengeruests und Lungentumoren. In diesem Beitrag werden die Moeglichkeiten und technischen Voraussetzungen der MRT zur Diagnostik der Lungenperfusion dargestellt. (orig.)

  13. Estimation of Lung Ventilation

    Science.gov (United States)

    Ding, Kai; Cao, Kunlin; Du, Kaifang; Amelon, Ryan; Christensen, Gary E.; Raghavan, Madhavan; Reinhardt, Joseph M.

    Since the primary function of the lung is gas exchange, ventilation can be interpreted as an index of lung function in addition to perfusion. Injury and disease processes can alter lung function on a global and/or a local level. MDCT can be used to acquire multiple static breath-hold CT images of the lung taken at different lung volumes, or with proper respiratory control, 4DCT images of the lung reconstructed at different respiratory phases. Image registration can be applied to this data to estimate a deformation field that transforms the lung from one volume configuration to the other. This deformation field can be analyzed to estimate local lung tissue expansion, calculate voxel-by-voxel intensity change, and make biomechanical measurements. The physiologic significance of the registration-based measures of respiratory function can be established by comparing to more conventional measurements, such as nuclear medicine or contrast wash-in/wash-out studies with CT or MR. An important emerging application of these methods is the detection of pulmonary function change in subjects undergoing radiation therapy (RT) for lung cancer. During RT, treatment is commonly limited to sub-therapeutic doses due to unintended toxicity to normal lung tissue. Measurement of pulmonary function may be useful as a planning tool during RT planning, may be useful for tracking the progression of toxicity to nearby normal tissue during RT, and can be used to evaluate the effectiveness of a treatment post-therapy. This chapter reviews the basic measures to estimate regional ventilation from image registration of CT images, the comparison of them to the existing golden standard and the application in radiation therapy.

  14. Pulmonary perfusion ''without ventilation''

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-12-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  15. Acute tumor vascular effects following fractionated radiotherapy in human lung cancer: In vivo whole tumor assessment using volumetric perfusion computed tomography

    International Nuclear Information System (INIS)

    Ng, Q.-S.; Goh, Vicky; Milner, Jessica; Padhani, Anwar R.; Saunders, Michele I.; Hoskin, Peter J.

    2007-01-01

    Purpose: To quantitatively assess the in vivo acute vascular effects of fractionated radiotherapy for human non-small-cell lung cancer using volumetric perfusion computed tomography (CT). Methods and Materials: Sixteen patients with advanced non-small-cell lung cancer, undergoing palliative radiotherapy delivering 27 Gy in 6 fractions over 3 weeks, were scanned before treatment, and after the second (9 Gy), fourth (18 Gy), and sixth (27 Gy) radiation fraction. Using 16-detector CT, multiple sequential volumetric acquisitions were acquired after intravenous contrast agent injection. Measurements of vascular blood volume and permeability for the whole tumor volume were obtained. Vascular changes at the tumor periphery and center were also measured. Results: At baseline, lung tumor vascularity was spatially heterogeneous with the tumor rim showing a higher vascular blood volume and permeability than the center. After the second, fourth, and sixth fractions of radiotherapy, vascular blood volume increased by 31.6% (paired t test, p = 0.10), 49.3% (p = 0.034), and 44.6% (p = 0.0012) respectively at the tumor rim, and 16.4% (p = 0.29), 19.9% (p = 0.029), and 4.0% (p = 0.0050) respectively at the center of the tumor. After the second, fourth, and sixth fractions of radiotherapy, vessel permeability increased by 18.4% (p = 0.022), 44.8% (p = 0.0048), and 20.5% (p = 0.25) at the tumor rim. The increase in permeability at the tumor center was not significant after radiotherapy. Conclusion: Fractionated radiotherapy increases tumor vascular blood volume and permeability in human non-small-cell lung cancer. We have established the spatial distribution of vascular changes after radiotherapy; greater vascular changes were demonstrated at the tumor rim compared with the center

  16. Effective avoidance of a functional spect-perfused lung using intensity modulated radiotherapy (IMRT) for non-small cell lung cancer (NSCLC): An update of a planning study

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Singh, Shalini; Christian, Judith A.; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; Bedford, James L.; Brada, Michael

    2009-01-01

    IMRT and 3-dimensional conformal radiotherapy (3-DCRT) plans of 25 patients with non-small cell lung (NSCLC) were compared in terms of planning target volume (PTV) coverage and sparing of functional lung (FL) defined by a SPECT perfusion scan. IMRT resulted in significant reduction of functional V 20 and mean lung dose in stage III patients with inhomogeneous hypoperfusion. If the dose to FL is shown to be the determinant of lung toxicity, IMRT would allow for effective dose escalation by specific avoidance of functional lung.

  17. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    International Nuclear Information System (INIS)

    Lutterbey, G.; Grohe, C.; Gieseke, J.; Falkenhausen, M. von; Morakkabati, N.; Wattjes, M.P.; Manka, R.; Trog, D.; Schild, H.H.

    2007-01-01

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  18. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    Energy Technology Data Exchange (ETDEWEB)

    Lutterbey, G. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)]. E-mail: goetz.lutterbey@ukb.uni-bonn.de; Grohe, C. [Department of Internal Medicine, University of Bonn (Germany); Gieseke, J. [PHILIPS Medical Systems, Best (Netherlands); Falkenhausen, M. von [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Morakkabati, N. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Wattjes, M.P. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Manka, R. [Department of Internal Medicine, University of Bonn (Germany); Trog, D. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Schild, H.H. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)

    2007-02-15

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  19. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent

    International Nuclear Information System (INIS)

    Fink, Christian; Ley, Sebastian; Puderbach, Michael; Plathow, Christian; Kauczor, Hans-Ulrich; Bock, Michael

    2004-01-01

    The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 ; voxel size: 1.3 x 2.5 x 4.0 mm 3 ; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 ; voxel size: 0.8 x 1.0 x 1.6 mm 3 ) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21±8 vs. 13±3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer. (orig.)

  20. CT quantification of lung and airways in normal Korean subjects

    International Nuclear Information System (INIS)

    Kim, Song Soo; Lee, Jeong Eun; Shin, Hye Soo; Jin, Gong Yong; Li, Yuan Zhe

    2017-01-01

    To measure and compare the quantitative parameters of the lungs and airways in Korean never-smokers and current or former smokers (“ever-smokers”). Never-smokers (n = 119) and ever-smokers (n = 45) who had normal spirometry and visually normal chest computed tomography (CT) results were retrospectively enrolled in this study. For quantitative CT analyses, the low attenuation area (LAA) of LAA_I_-_9_5_0, LAA_E_-_8_5_6, CT attenuation value at the 15th percentile, mean lung attenuation (MLA), bronchial wall thickness of inner perimeter of a 10 mm diameter airway (Pi10), total lung capacity (TLC_C_T), and functional residual capacity (FRC_C_T) were calculated based on inspiratory and expiratory CT images. To compare the results between groups according to age, sex, and smoking history, independent t test, one way ANOVA, correlation test, and simple and multiple regression analyses were performed. The values of attenuation parameters and volume on inspiratory and expiratory quantitative computed tomography (QCT) were significantly different between males and females (p < 0.001). The MLA and the 15th percentile value on inspiratory QCT were significantly lower in the ever-smoker group than in the never-smoker group (p < 0.05). On expiratory QCT, all lung attenuation parameters were significantly different according to the age range (p < 0.05). Pi10 in ever-smokers was significantly correlated with forced expiratory volume in 1 second/forced vital capacity (r = −0.455, p = 0.003). In simple and multivariate regression analyses, TLC_C_T, FRC_C_T, and age showed significant associations with lung attenuation (p < 0.05), and only TLC_C_T was significantly associated with inspiratory Pi10. In Korean subjects with normal spirometry and visually normal chest CT, there may be significant differences in QCT parameters according to sex, age, and smoking history

  1. CT findings of small bowel metastases from primary lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Wook; Ha, Hyun Kwon; Kim, Ah Young; Kim, Gab Choul; Kim, Tae Kyoung; Kim, Pyo Nyun; Lee, Moon Gyu [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2002-11-01

    To evaluate the CT findings of small bowel metastases from primary lung cancer. Of the 1468 patients with primary lung cancer between 1990 and 2000, 13 patients who had metastasis to the small intestine were collected. Of these 13 patients, nine who underwent CT scan were included for analysis. The pathologic diagnoses of primary lung cancer in these nine patients were squamous cell carcinoma in six, adenocarcinoma in two, and large cell carcinoma in one. CT scans were analyzed with regard to the site and patterns (intraluminal mass/bowel wall thickening/bowel implants) of metastatic masses, and the presence or absence of complication such as intussusception, obstruction, or perforation of the small bowel. The medical records of the patients were also reviewed retrospectively for evaluation of presenting abdominal symptom and time interval of metastases from initial diagnosis of lung cancer. Metastatic lesions were distributed throughout the small intestine: the duodenum in five, the jejunum in four, the ileum in six, and both jejunum and ileum in one patient. The size of metastatic masses of small bowel ranged from 1.3 cm to 5.0 cm (mean size, 2.6 cm) On CT, the small bowel was involved with intraluminal masses (mean size, 3.4 cm) in eight patients, diffuse wall thickening (mean thickness, 1.6 cm) in five, and bowel implants (mean size, 2.2 cm) in two. Complications occurred in seven patients, including intussusceptions without obstruction in two patients and with obstruction in two, obstruction without intussusceptions in two, and bowel perforation in one. Of 9 patients, 6 had at least one symptom referable to the small bowel including abdominal pain in 4, anemia in 3, vomiting in 1, and jaundice in 1. Lung cancer and small bowel lesions were detected simultaneously in four patients and the time interval of metastases from initial diagnosis of lung cancer ranged from 10 days to 30 months (median interval, 54 days) in patients. CT helps in defining the extent and

  2. CT findings of small bowel metastases from primary lung cancer

    International Nuclear Information System (INIS)

    Kim, Jae Wook; Ha, Hyun Kwon; Kim, Ah Young; Kim, Gab Choul; Kim, Tae Kyoung; Kim, Pyo Nyun; Lee, Moon Gyu

    2002-01-01

    To evaluate the CT findings of small bowel metastases from primary lung cancer. Of the 1468 patients with primary lung cancer between 1990 and 2000, 13 patients who had metastasis to the small intestine were collected. Of these 13 patients, nine who underwent CT scan were included for analysis. The pathologic diagnoses of primary lung cancer in these nine patients were squamous cell carcinoma in six, adenocarcinoma in two, and large cell carcinoma in one. CT scans were analyzed with regard to the site and patterns (intraluminal mass/bowel wall thickening/bowel implants) of metastatic masses, and the presence or absence of complication such as intussusception, obstruction, or perforation of the small bowel. The medical records of the patients were also reviewed retrospectively for evaluation of presenting abdominal symptom and time interval of metastases from initial diagnosis of lung cancer. Metastatic lesions were distributed throughout the small intestine: the duodenum in five, the jejunum in four, the ileum in six, and both jejunum and ileum in one patient. The size of metastatic masses of small bowel ranged from 1.3 cm to 5.0 cm (mean size, 2.6 cm) On CT, the small bowel was involved with intraluminal masses (mean size, 3.4 cm) in eight patients, diffuse wall thickening (mean thickness, 1.6 cm) in five, and bowel implants (mean size, 2.2 cm) in two. Complications occurred in seven patients, including intussusceptions without obstruction in two patients and with obstruction in two, obstruction without intussusceptions in two, and bowel perforation in one. Of 9 patients, 6 had at least one symptom referable to the small bowel including abdominal pain in 4, anemia in 3, vomiting in 1, and jaundice in 1. Lung cancer and small bowel lesions were detected simultaneously in four patients and the time interval of metastases from initial diagnosis of lung cancer ranged from 10 days to 30 months (median interval, 54 days) in patients. CT helps in defining the extent and

  3. WE-B-207-02: CT Lung Cancer Screening and the Medical Physicist: A Dosimetry Summary of CT Participants in the National Lung Cancer Screening Trial (NLST)

    International Nuclear Information System (INIS)

    Lee, C.

    2015-01-01

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Under the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan

  4. WE-B-207-02: CT Lung Cancer Screening and the Medical Physicist: A Dosimetry Summary of CT Participants in the National Lung Cancer Screening Trial (NLST)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. [National Cancer Institute (United States)

    2015-06-15

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Under the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan

  5. Assessment of airway lesion in obstructive lung diseases by CT

    International Nuclear Information System (INIS)

    Niimi, Akio; Matsumoto, Hisako; Ueda, Tetsuya; Mishima, Michiaki

    2002-01-01

    Airway lesion in obstructive pulmonary diseases, such as asthma or chronic obstructive pulmonary disease (COPD), has recently been assessed quantitatively. Especially in asthma, wall thickening of central airways, and its relation to the severity of disease or airflow obstruction has been clarified. Pathophysiologic importance of peripheral airway lesion has also been highlighted by pathologic or physiologic studies. However, direct evaluation of peripheral airway lesion is beyond resolutional limitation of CT. To assess airway trapping, an indirect CT finding of peripheral airway disease, by quantitative and semiquantitative measures and compare them with clinical indices such as pulmonary function, airway responsiveness, or airway inflammation. Patients with stable asthma (n=20) were studied. HRCT at 3 levels of both lungs were scanned. Low attenuation area (LAA)% and mean lung density were quantitatively assessed by an automatic method. Distribution of mosaic pattern was visually scored semiquantitatively. LAA% and mean lung density at full expiratory phase correlated with the degree of airflow obstruction. Mosaic score at full inspiratory phase correlated with the severity of disease and airflow obstruction. Expiratory/inspiratory ratio of mean lung density was also associated with airway responsiveness or residual volume/total lung capacity (RV/TLC). These CT findings may be useful as markers of asthma pathophysiology. (author)

  6. Longitudinal micro-CT as an outcome measure of interstitial lung disease in TNF-transgenic mice.

    Directory of Open Access Journals (Sweden)

    Richard D Bell

    Full Text Available Rheumatoid arthritis associated interstitial lung disease (RA-ILD is a debilitating condition with poor survival prognosis. High resolution computed tomography (CT is a common clinical tool to diagnose RA-ILD, and is increasingly being adopted in pre-clinical studies. However, murine models recapitulating RA-ILD are lacking, and CT outcomes for inflammatory lung disease have yet to be formally validated. To address this, we validate μCT outcomes for ILD in the tumor necrosis factor transgenic (TNF-Tg mouse model of RA.Cross sectional μCT was performed on cohorts of male TNF-Tg mice and their WT littermates at 3, 4, 5.5 and 12 months of age (n = 4-6. Lung μCT outcomes measures were determined by segmentation of the μCT datasets to generate Aerated and Tissue volumes. After each scan, lungs were obtained for histopathology and 3 sections stained with hematoxylin and eosin. Automated histomorphometry was performed to quantify the tissue area (nuclei, cytoplasm, and extracellular matrix and aerated area (white space within the tissue sections. Spearman's correlation coefficients were used to evaluate the extent of association between μCT imaging and histopathology endpoints.TNF-Tg mice had significantly greater tissue volume, total lung volume and mean intensity at all timepoints compared to age matched WT littermates. Histomorphometry also demonstrated a significant increase in tissue area at 3, 4, and 5.5 months of age in TNF-Tg mice. Lung tissue volume was correlated with lung tissue area (ρ = 0.81, p<0.0001, and normalize lung aerated volume was correlated with normalized lung air area (ρ = 0.73, p<0.0001.We have validated in vivo μCT as a quantitative biomarker of ILD in mice. Further, development of longitudinal measures is critical for dissecting pathologic progression of ILD, and μCT is a useful non-invasive method to study lung inflammation in the TNF-Tg mouse model.

  7. The contribution of CT-guided transthoracic lung biopsy to the diagnosis of organising pneumonia.

    Science.gov (United States)

    Metzger, F; Pernet, D; Manzoni, P; Ranfaing, E; Dalphin, J-C

    2010-09-01

    Organising pneumonia is a pulmonary disease with variable clinical and radiological features and with many differential diagnoses. Diagnosis is based on histology obtained by either transbronchial or surgical lung biopsy but these techniques have several disadvantages. The aim of this study was to evaluate the diagnostic yield of CT-guided transthoracic lung biopsy in organising pneumonia and to compare it to the usual diagnostic tools. Six cases of organising pneumonia diagnosed with CT-guided lung biopsy are reported and discussed. The role of CT-guided lung biopsy in the diagnosis of organising pneumonia was also reviewed in the literature. CT-guided transthoracic lung biopsies provided a higher rate of adequate samples than transbronchial biopsies (92-100% versus 77-86%). The samples were larger, which reduced the risks of misdiagnosis and increased the diagnostic yield (88-97% versus 26-55% in pulmonary nodules and 42-100% versus 66-75% in diffuse pulmonary disease). Complications were rare and generally not serious. CT-guided transthoracic lung biopsy may be considered in place of transbronchial biopsy in the diagnosis of organising pneumonia. Surgical lung biopsy remains the gold standard method for diagnosis. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  8. Relations between CT perfusion parameters and degree of hepatic ischemia reperfusion injury in a rabbit model

    International Nuclear Information System (INIS)

    Guo Chengwei; Shen Sandi; Yi Xianlin; Zhang Zhonglin; Liu Zaiyi; Liang Changhong

    2011-01-01

    Objective: To observe the changes of hepatic CT perfusion parameters and their correlation with serum aspartate transaminase (AST), alanine transaminase (ALT) and alkaline phosphatase (ALP) in a rabbit hepatic ischemia reperfusion injury (IRI) model. Methods: Hepatic IRI was produced in rabbits by inducing left liver lobe ischemia (60 min) followed by 6 h, 12 h and 24 h reperfusion (6 rabbits were used for each reperfusion interval). Additional 6 rabbits were served as sham-operated controls. All the rabbits were scanned with a dynamic iCT protocol. Blood samples were taken from the superior mesenteric vein to measure the levels of serum amylase (ALT, AST, and ALP) in various groups, and liver samples were taken for histological examinations after scanning. One-way analysis of variance (ANOVA) was used to determine differences between groups. The correlations of CT perfusion parameters with serum levels were analyzed using Pearson correlation coefficient. Results: Heterogeneity of CT perfusion patterns appeared in the 6 h groups, which presented as low enhanced area [(25.1±9.3) ml · min -1 · 100 mg -1 ]. In reduced perfusion regions of IRI group, HAP of 12 h IRI group [(19.5± 13.6) ml · min -1 · 100 mg -1 ], 24 h IRI group (8.0±2.7) ml · min -1 · 100 mg -1 ], HPP of 6 h IRI group [(10.8±5.5) ml · min -1 · 100 mg -1 ], 12 h IRI group [(14.4±5.2) ml · min -1 · 100 mg -1 ] , 24 h IRI group [(7.8±3.3) ml · min -1 · 100 mg -1 ] and TLP of 6 h IRI group [(35.9±14.0) ml · min -1 · 100 mg -1 ], 12 h IRI group [(33.9±16.1) ml · min -1 · 100 mg -1 ], 24 h IRI group [(16.0± 5.5) ml · min -1 · 100 mg -1 ] were lower than those of sham group [HAP (21.2±10.5) ml · min -1 · 100 mg -1 , HPP (63.5±24.0) ml · min -1 · 100 mg -1 , TLP (81.4±24.8) ml · min -1 · 100 mg -1 ] (F=8.376, 25.950, 16.925, P<0.01). However, HPI of 6 h IRI group [(65.9±3.9)%], 12 h IRI group [(54.2±16.7)%], and 24 h IRI group [(48.9±10.0)%] were higher compared to sham

  9. Histogram Analysis of CT Perfusion of Hepatocellular Carcinoma for Predicting Response to Transarterial Radioembolization: Value of Tumor Heterogeneity Assessment

    International Nuclear Information System (INIS)

    Reiner, Caecilia S.; Gordic, Sonja; Puippe, Gilbert; Morsbach, Fabian; Wurnig, Moritz; Schaefer, Niklaus; Veit-Haibach, Patrick; Pfammatter, Thomas; Alkadhi, Hatem

    2016-01-01

    PurposeTo evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE).Materials and MethodsSixteen patients (15 male; mean age 65 years; age range 47–80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters’ ability to discriminate responders from non-responders.ResultsAccording to mRECIST, 8 patients (50 %) were responders and 8 (50 %) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min −1  100 mL −1 ); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min −1  100 mL −1 ; p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min −1  100 mL −1 , therapy response could be predicted with a sensitivity of 88 % (7/8) and specificity of 75 % (6/8).ConclusionVoxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE

  10. Methods of in-vivo mouse lung micro-CT

    Science.gov (United States)

    Recheis, Wolfgang A.; Nixon, Earl; Thiesse, Jacqueline; McLennan, Geoffrey; Ross, Alan; Hoffman, Eric

    2005-04-01

    Micro-CT will have a profound influence on the accumulation of anatomical and physiological phenotypic changes in natural and transgenetic mouse models. Longitudinal studies will be greatly facilitated, allowing for a more complete and accurate description of events if in-vivo studies are accomplished. The purpose of the ongoing project is to establish a feasible and reproducible setup for in-vivo mouse lung micro-computed tomography (μCT). We seek to use in-vivo respiratory-gated μCT to follow mouse models of lung disease with subsequent recovery of the mouse. Methodologies for optimizing scanning parameters and gating for the in-vivo mouse lung are presented. A Scireq flexiVent ventilated the gas-anesthetized mice at 60 breaths/minute, 30 cm H20 PEEP, 30 ml/kg tidal volume and provided a respiratory signal to gate a Skyscan 1076 μCT. Physiologic monitoring allowed the control of vital functions and quality of anesthesia, e.g. via ECG monitoring. In contrary to longer exposure times with ex-vivo scans, scan times for in-vivo were reduced using 35μm pixel size, 158ms exposure time and 18μm pixel size, 316ms exposure time to reduce motion artifacts. Gating via spontaneous breathing was also tested. Optimal contrast resolution was achieved at 50kVp, 200μA, applying an aluminum filter (0.5mm). There were minimal non-cardiac related motion artifacts. Both 35μm and 1μm voxel size images were suitable for evaluation of the airway lumen and parenchymal density. Total scan times were 30 and 65 minutes respectively. The mice recovered following scanning protocols. In-vivo lung scanning with recovery of the mouse delivered reasonable image quality for longitudinal studies, e.g. mouse asthma models. After examining 10 mice, we conclude μCT is a feasible tool evaluating mouse models of lung pathology in longitudinal studies with increasing anatomic detail available for evaluation as one moves from in-vivo to ex-vivo studies. Further developments include automated

  11. Two methods for isolating the lung area of a CT scan for density information

    International Nuclear Information System (INIS)

    Hedlund, L.W.; Anderson, R.F.; Goulding, P.L.; Beck, J.W.; Effmann, E.L.; Putman, C.E.

    1982-01-01

    Extracting density information from irregularly shaped tissue areas of CT scans requires automated methods when many scans are involved. We describe two computer methods that automatically isolate the lung area of a CT scan. Each starts from a single, operator specified point in the lung. The first method follows the steep density gradient boundary between lung and adjacent tissues; this tracking method is useful for estimating the overall density and total area of lung in a scan because all pixels within the lung area are available for statistical sampling. The second method finds all contiguous pixels of lung that are within the CT number range of air to water and are not a part of strong density gradient edges; this method is useful for estimating density and area of the lung parenchyma. Structures within the lung area that are surrounded by strong density gradient edges, such as large blood vessels, airways and nodules, are excluded from the lung sample while lung areas with diffuse borders, such as an area of mild or moderate edema, are retained. Both methods were tested on scans from an animal model of pulmonary edema and were found to be effective in isolating normal and diseased lungs. These methods are also suitable for isolating other organ areas of CT scans that are bounded by density gradient edges

  12. Resolution enhancement of lung 4D-CT via group-sparsity

    International Nuclear Information System (INIS)

    Bhavsar, Arnav; Wu, Guorong; Shen, Dinggang; Lian, Jun

    2013-01-01

    Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as

  13. MRI methods for pulmonary ventilation and perfusion imaging; Methoden der MRT zur Ventilations- und Perfusionsbildgebung der Lunge

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Bauman, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin - Radiologische Physik, Basel (Switzerland)

    2016-02-15

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O{sub 2}-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [German] Die separate Beurteilung von Atemmechanik, Gasaustauschprozessen und Lungenzirkulation ist wesentlich fuer die Diagnose und Therapie von Lungenerkrankungen. Klinische Lungenfunktionstests sind aufgrund ihrer zumeist nur globalen Aussage oft nicht hinreichend spezifisch in der Differenzialdiagnostik oder eingeschraenkt sensitiv bei der

  14. Dynamic Chest Image Analysis: Model-Based Perfusion Analysis in Dynamic Pulmonary Imaging

    Directory of Open Access Journals (Sweden)

    Kiuru Aaro

    2003-01-01

    Full Text Available The "Dynamic Chest Image Analysis" project aims to develop model-based computer analysis and visualization methods for showing focal and general abnormalities of lung ventilation and perfusion based on a sequence of digital chest fluoroscopy frames collected with the dynamic pulmonary imaging technique. We have proposed and evaluated a multiresolutional method with an explicit ventilation model for ventilation analysis. This paper presents a new model-based method for pulmonary perfusion analysis. According to perfusion properties, we first devise a novel mathematical function to form a perfusion model. A simple yet accurate approach is further introduced to extract cardiac systolic and diastolic phases from the heart, so that this cardiac information may be utilized to accelerate the perfusion analysis and improve its sensitivity in detecting pulmonary perfusion abnormalities. This makes perfusion analysis not only fast but also robust in computation; consequently, perfusion analysis becomes computationally feasible without using contrast media. Our clinical case studies with 52 patients show that this technique is effective for pulmonary embolism even without using contrast media, demonstrating consistent correlations with computed tomography (CT and nuclear medicine (NM studies. This fluoroscopical examination takes only about 2 seconds for perfusion study with only low radiation dose to patient, involving no preparation, no radioactive isotopes, and no contrast media.

  15. Optimization of CT image reconstruction algorithms for the lung tissue research consortium (LTRC)

    Science.gov (United States)

    McCollough, Cynthia; Zhang, Jie; Bruesewitz, Michael; Bartholmai, Brian

    2006-03-01

    To create a repository of clinical data, CT images and tissue samples and to more clearly understand the pathogenetic features of pulmonary fibrosis and emphysema, the National Heart, Lung, and Blood Institute (NHLBI) launched a cooperative effort known as the Lung Tissue Resource Consortium (LTRC). The CT images for the LTRC effort must contain accurate CT numbers in order to characterize tissues, and must have high-spatial resolution to show fine anatomic structures. This study was performed to optimize the CT image reconstruction algorithms to achieve these criteria. Quantitative analyses of phantom and clinical images were conducted. The ACR CT accreditation phantom containing five regions of distinct CT attenuations (CT numbers of approximately -1000 HU, -80 HU, 0 HU, 130 HU and 900 HU), and a high-contrast spatial resolution test pattern, was scanned using CT systems from two manufacturers (General Electric (GE) Healthcare and Siemens Medical Solutions). Phantom images were reconstructed using all relevant reconstruction algorithms. Mean CT numbers and image noise (standard deviation) were measured and compared for the five materials. Clinical high-resolution chest CT images acquired on a GE CT system for a patient with diffuse lung disease were reconstructed using BONE and STANDARD algorithms and evaluated by a thoracic radiologist in terms of image quality and disease extent. The clinical BONE images were processed with a 3 x 3 x 3 median filter to simulate a thicker slice reconstructed in smoother algorithms, which have traditionally been proven to provide an accurate estimation of emphysema extent in the lungs. Using a threshold technique, the volume of emphysema (defined as the percentage of lung voxels having a CT number lower than -950 HU) was computed for the STANDARD, BONE, and BONE filtered. The CT numbers measured in the ACR CT Phantom images were accurate for all reconstruction kernels for both manufacturers. As expected, visual evaluation of the

  16. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  17. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W.; Klotz, E.; Ditt, H.

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs eff. , using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue. (orig.)

  18. Clinical value of 99Tcm-octreotide SPECT/CT in diagnostics of lung cancer

    International Nuclear Information System (INIS)

    Liu Xiaofang; Li Mei; Liu Yong; Li Ran; Xu Jie; Sun yongchang; Dai Haojie

    2012-01-01

    Objective: To evaluate the clinical value of 99 Tc m -Octreotide SPECT-CT in the diagnosis of lung cancer. Methods: Sixty-five consecutive patients with suspected lung cancer received intravenous injection of 740 MBq 99 Tc m -Octreotide and additional SPECT images of the chest were performed at 4h post injection. The SPECT/CT images were interpreted separately. The tumor uptake of 99 Tc m -Octreotide was visually determined and then measured and expressed as the activity ratio of tumor to normal tissues (T/N). The differences between lung cancer and benign lung lesion and between SCLC and NSCLC, and between adenocarcinoma and squamous carcinoma were studied by statistical analysis. Moreover, the receiver operating characteristic ROC curves were plotted and the predicted probabilities and areas under the curve were calculated. Results: Fifty-one patients and fourteen patients in 65 cases were diagnosed as lung cancer and benign lung lesion by histopathological analysis, respectively. The sensitivity, specificity, positive predictive value and negative predictive value of 99 Tc m -Octreotide SPECT/CT in diagnosis of lung cancer were 92.2%, 85.7%, 95.9% and 75%, respectively. The area under ROC curve was 0.889 (P 99 Tc m -Octreotide SPECT/CT could play an important role in the diagnosis of lung cancer, and it may be useful for identifying SCLC and NSCLC. (authors)

  19. Heterogeneity of pulmonary perfusion as a mechanistic image-based phenotype in emphysema susceptible smokers.

    Science.gov (United States)

    Alford, Sara K; van Beek, Edwin J R; McLennan, Geoffrey; Hoffman, Eric A

    2010-04-20

    Recent evidence suggests that endothelial dysfunction and pathology of pulmonary vascular responses may serve as a precursor to smoking-associated emphysema. Although it is known that emphysematous destruction leads to vasculature changes, less is known about early regional vascular dysfunction which may contribute to and precede emphysematous changes. We sought to test the hypothesis, via multidetector row CT (MDCT) perfusion imaging, that smokers showing early signs of emphysema susceptibility have a greater heterogeneity in regional perfusion parameters than emphysema-free smokers and persons who had never smoked (NS). Assuming that all smokers have a consistent inflammatory response, increased perfusion heterogeneity in emphysema-susceptible smokers would be consistent with the notion that these subjects may have the inability to block hypoxic vasoconstriction in patchy, small regions of inflammation. Dynamic ECG-gated MDCT perfusion scans with a central bolus injection of contrast were acquired in 17 NS, 12 smokers with normal CT imaging studies (SNI), and 12 smokers with subtle CT findings of centrilobular emphysema (SCE). All subjects had normal spirometry. Quantitative image analysis determined regional perfusion parameters, pulmonary blood flow (PBF), and mean transit time (MTT). Mean and coefficient of variation were calculated, and statistical differences were assessed with one-way ANOVA. MDCT-based MTT and PBF measurements demonstrate globally increased heterogeneity in SCE subjects compared with NS and SNI subjects but demonstrate similarity between NS and SNI subjects. These findings demonstrate a functional lung-imaging measure that provides a more mechanistically oriented phenotype that differentiates smokers with and without evidence of emphysema susceptibility.

  20. Evaluation of optimal scan duration and end time in cerebral CT perfusion study

    International Nuclear Information System (INIS)

    Hirata, Masaaki; Sugawara, Yoshifumi; Miki, Hitoshi; Mochizuki, Teruhito; Murase, Kenya

    2005-01-01

    The purpose of this study was to evaluate the optimal end time of scanning and the influence of varying the number of source images adopted for calculation of the parameter values in computerized tomography (CT) perfusion. Nineteen CT perfusion studies in 14 patients with cerebrovascular disease were retrospectively analyzed. CT perfusion scanning was performed using continuous scans of 1 sec/rotation x 60 sec with 5-mm-thick sections. To determine the appropriate end time of scanning, the time-density curves (TDCs) of the anterior cerebral artery (ACA), superior sagittal sinus (SSS), and basal ganglia were analyzed. The functional maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) were retrospectively generated from various numbers (30, 35, 40, 45, 50, 55, and 60) of source images. Defining the values calculated from the number of source images equal to the end time of the first pass as standard values, the percentage difference between the standard values and the values generated from various numbers of sources were evaluated. The TDCs of SSS showed the latest end time of the first pass (mean, 38.6±5.2 sec; range, 32 to 48 sec). Therefore, the values calculated from the number of source images equal to the end time of the first pass of SSS were defined as standard values. Increase and decrease of the number of source images for calculation resulted in increase of the percentage difference in every parameter value. The percentage differences ranged up to 49.6% for CBF, 48.0% for CBV, and 20.0% for MTT. Scanning until the end time of the first pass of SSS is necessary and sufficient for reliable measurement. Variable scan time based on the TDC of the SSS may be of better utility than use of fixed scan time. Further, the radiation dose could be minimized in many cases by reducing the scan time. (author)

  1. Quantitative assessment of smoking-induced emphysema progression in longitudinal CT screening for lung cancer

    Science.gov (United States)

    Suzuki, H.; Mizuguchi, R.; Matsuhiro, M.; Kawata, Y.; Niki, N.; Nakano, Y.; Ohmatsu, H.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, M.; Moriyama, N.

    2015-03-01

    Computed tomography has been used for assessing structural abnormalities associated with emphysema. It is important to develop a robust CT based imaging biomarker that would allow quantification of emphysema progression in early stage. This paper presents effect of smoking on emphysema progression using annual changes of low attenuation volume (LAV) by each lung lobe acquired from low-dose CT images in longitudinal screening for lung cancer. The percentage of LAV (LAV%) was measured after applying CT value threshold method and small noise reduction. Progression of emphysema was assessed by statistical analysis of the annual changes represented by linear regression of LAV%. This method was applied to 215 participants in lung cancer CT screening for five years (18 nonsmokers, 85 past smokers, and 112 current smokers). The results showed that LAV% is useful to classify current smokers with rapid progression of emphysema (0.2%/year, pemphysema in CT screening for lung cancer.

  2. Resectable stage III lung cancer: CT, surgical, and pathologic correlation

    International Nuclear Information System (INIS)

    Scott, I.R.; Muller, N.L.; Miller, R.R.; Evans, K.G.; Nelems, B.

    1987-01-01

    Patients with stage IIIa lung cancer have improved survival following surgery. The authors reviewed the CT, surgical, and pathologic findings in 26 patients with completely resected stage IIIa lung cancer. These include examples of the different subsets of stage IIIa disease. CT correctly predicted chest-wall invasion in only two of ten patients, pericardial involvement in one of three, and tumor extension to within 2 cm of the carina in one of three patients. It detected mediastinal nodal disease in eight of 11 patients. CT is of limited value in assessing chest-wall or pericardial extension; however, such extension does not preclude complete resection. Ipsilateral nodal involvement also doses not preclude surgery

  3. Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

    Science.gov (United States)

    Bretas, Elisa Almeida Sathler; Torres, Ulysses S; Torres, Lucas Rios; Bekhor, Daniel; Saito Filho, Celso Fernando; Racy, Douglas Jorge; Faggioni, Lorenzo; D'Ippolito, Giuseppe

    2017-10-01

    To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages. This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics. Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters. At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.

  4. Direct assessment of lung function in COPD using CT densitometric measures

    International Nuclear Information System (INIS)

    Gu, Suicheng; Leader, Joseph; Gur, David; Pu, Jiantao; Zheng, Bin; Chen, Qihang; Sciurba, Frank; Kminski, Naftali

    2014-01-01

    To investigate whether lung function in patients with chronic obstructive pulmonary disease (COPD) can be directly predicted using CT densitometric measures and assess the underlying prediction errors as compared with the traditional spirometry-based measures. A total of 600 CT examinations were collected from a COPD study. In addition to the entire lung volume, the extent of emphysema depicted in each CT examination was quantified using density mask analysis (densitometry). The partial least square regression was used for constructing the prediction model, where a repeated random split-sample validation was employed. For each split, we randomly selected 400 CT exams for training (regression) purpose and the remaining 200 exams for assessing performance in prediction of lung function (e.g., FEV1 and FEV1/FVC) and disease severity. The absolute and percentage errors as well as their standard deviations were computed. The averaged percentage errors in prediction of FEV1, FEV1/FVC%, TLC, RV/TLC% and DLco% predicted were 33%, 17%, 9%, 18% and 23%, respectively. When classifying the exams in terms of disease severity grades using the CT measures, 37% of the subjects were correctly classified with no error and 83% of the exams were either correctly classified or classified into immediate neighboring categories. The linear weighted kappa and quadratic weighted kappa were 0.54 (moderate agreement) and 0.72 (substantial agreement), respectively. Despite the existence of certain prediction errors in quantitative assessment of lung function, the CT densitometric measures could be used to relatively reliably classify disease severity grade of COPD patients in terms of GOLD. (paper)

  5. Information for the diagnosis of broncho-pulmonary diseases obtained by the combined use of perfusion lung scintigraphy and selective bronchial arteriography

    International Nuclear Information System (INIS)

    Wouamba Foning, Michel.

    1976-01-01

    Our study is limited to perfusion lung scintigraphy and deals with the following in turn: - radioisotopes and their conditioning, - detection and recording equipment, - results and limits of the method. The tracers used here were radioiodine-labelled human albumin macro-aggregates and more especially technetium-labelled microspheres. Scintigraphy, which visualizes or charts the local distribution of radioactive indicators, is carried out with two kinds of apparatus, scanners and scintillation cameras. The information acquired may be accurately analysed at the same time owing to modern data processing systems. The interpretation of radiotracer lung transit curves made by several authors is not very useful for our work, consequently we have kept to the analysis of images obtained by the Anger camera or similar instruments. The Anger scintillation camera seems to be well suited to isotopic lung exploration providing morphological and functional data simultaneously. Perfusion lung scintigraphy, which reflects the quality of lung circulation at the capillary level, appears to be a valuable asset in the diagnostic approach to certain chest X-ray images. The technique is fast, painless, neat, harmless and almost never contra-indicated. However like other techniques it cannot solve every problem on its own. Under these conditions, we must admit, on weighing up the results of this study, that perfusion lung scintigraphy had to be followed in most cases by selective bronchial arteriography [fr

  6. Pulmonary O2 transfer during pulsatile and non-pulsatile perfusion.

    Science.gov (United States)

    Hauge, A; Nicolaysen, G

    1980-07-01

    The importance of the perfusion pattern for the oxygen transfer has been examined in isolated rabbit lungs perfused with plasma at constant volume inflow. The lungs were ventilated with constant tidal volume and constant end-expiratory pressure. Following a standardized rise in FIO2 the rate of rise in pulmonary venous PO2 (delta PO2/delta t) was measured during alternately pulsatile and non-pulsatile perfusion in normal lungs and in lungs made edematous by elevation of left atrial pressure. In normal lungs there was no difference in delta PO2/delta t when the two modes of perfusion were compared. In edematous lungs delta PO/delta t was statistically higher during pulsatile perfusion, indicating a beneficial effect of flow- and pressure pulsations, e.g. a better distribution of V/Q ratios throughout the lungs. In a separate series of expts. the advancement of a high O2 front through the airways was measured, and the two perfusion patterns compared. Since no difference was found, we suggest that the phenomenon of "cardiogenic gas mixing" in the airways in vivo is a result of a direct action of the heart on the lungs rather than arterial pulsations.

  7. CT findings of adenocarcinoma of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, T. J.; Kim, S. J.; Lee, D. Y.; Ahn, C. M [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-03-01

    To evaluate CT findings of primary adenocarcinoma of the lung and to assess distant metastasis at the time of diagnosis. CT findings of 150 patients with adenocarcinoma, confirmed by histopathologic methods, were classified as central or peripheral lesion and pattern analysis of typical findings noted in this cancer was carried out. Intra and extrathoracic metastases of adenocarcinoma were also investigated. Of 150 cases of adenocarcinoma of the lung, 121 were found to be of the peripheral type and 29 were of the central type. These peripheral lesions comprised 105 nodules, 11 consolidations, four cavities and one linear lesion, while the central lesions consisted of 19 cases of atelectasis and tens of branchial wall thickening. lung to lung(nine cases), lymphangitic(five cases), and pleural metastasis(16 cases) were presented as intrathoracic metastasis, while bone(17), brain,(six), liver(two) and adrenal metastasis(one case)were presented as extrathoracic metastasis. The most common radiologic finding of adenocarcinoma is a peripheral single mass or nodule but consolidation, cavity or tubular lesions, as well as atelectasis or bronchial wall thickening alone can be presented as unusual findings of adenocarcinoma. As a consequence, it is in many cases difficult to differentially diagnose. Distant metastasis was also noted in many cases of early T-stage lesion, so to successfully manage the patient, careful evaluation of the metastasis is essential.

  8. CT findings of adenocarcinoma of the lung

    International Nuclear Information System (INIS)

    Jeon, T. J.; Kim, S. J.; Lee, D. Y.; Ahn, C. M

    1996-01-01

    To evaluate CT findings of primary adenocarcinoma of the lung and to assess distant metastasis at the time of diagnosis. CT findings of 150 patients with adenocarcinoma, confirmed by histopathologic methods, were classified as central or peripheral lesion and pattern analysis of typical findings noted in this cancer was carried out. Intra and extrathoracic metastases of adenocarcinoma were also investigated. Of 150 cases of adenocarcinoma of the lung, 121 were found to be of the peripheral type and 29 were of the central type. These peripheral lesions comprised 105 nodules, 11 consolidations, four cavities and one linear lesion, while the central lesions consisted of 19 cases of atelectasis and tens of branchial wall thickening. lung to lung(nine cases), lymphangitic(five cases), and pleural metastasis(16 cases) were presented as intrathoracic metastasis, while bone(17), brain,(six), liver(two) and adrenal metastasis(one case)were presented as extrathoracic metastasis. The most common radiologic finding of adenocarcinoma is a peripheral single mass or nodule but consolidation, cavity or tubular lesions, as well as atelectasis or bronchial wall thickening alone can be presented as unusual findings of adenocarcinoma. As a consequence, it is in many cases difficult to differentially diagnose. Distant metastasis was also noted in many cases of early T-stage lesion, so to successfully manage the patient, careful evaluation of the metastasis is essential

  9. Low dose CT in early lung cancer diagnosis: prevalence data

    International Nuclear Information System (INIS)

    Cardinale, Luciano; Cortese, Giancarlo; Ferraris, Fabrizio; Perotto, Fabio; Fava, Cesare; Borasio, Piero; Dogliotti, Luigi; Novello, Silvia; Scagliotti, Giorgio

    2005-01-01

    Purpose. Lung cancer has a high mortality rate and its prognosis largely depends on early detection. We report the prevalence data of the study on early detection of lung cancer with low-dose spiral CT underway at our hospital. Materials and methods. Since the beginning of 2001, 519 asymptomatic volunteers have undergone annual blood tests, sputum tests, urinalyses and low-dose spiral CT. The inclusion criteria were age (55 years old), a history of cigarette smoking and a negative history for previous neoplastic disease. The diagnostic workup varied depending on the size and CT features of the nodules detected. Results. At baseline, the CT scan detected nodules> 5 mm in 22% of subjects; the nodules were single in 42 and multiple in 71. In 53% of cases the findings were completely negative, while in 122 (23.4%) nodules with a diameter [it

  10. Adaptive statistical iterative reconstruction improves image quality without affecting perfusion CT quantitation in primary colorectal cancer

    Directory of Open Access Journals (Sweden)

    D. Prezzi

    Full Text Available Objectives: To determine the effect of Adaptive Statistical Iterative Reconstruction (ASIR on perfusion CT (pCT parameter quantitation and image quality in primary colorectal cancer. Methods: Prospective observational study. Following institutional review board approval and informed consent, 32 patients with colorectal adenocarcinoma underwent pCT (100 kV, 150 mA, 120 s acquisition, axial mode. Tumour regional blood flow (BF, blood volume (BV, mean transit time (MTT and permeability surface area product (PS were determined using identical regions-of-interests for ASIR percentages of 0%, 20%, 40%, 60%, 80% and 100%. Image noise, contrast-to-noise ratio (CNR and pCT parameters were assessed across ASIR percentages. Coefficients of variation (CV, repeated measures analysis of variance (rANOVA and Spearman’ rank order correlation were performed with statistical significance at 5%. Results: With increasing ASIR percentages, image noise decreased by 33% while CNR increased by 61%; peak tumour CNR was greater than 1.5 with 60% ASIR and above. Mean BF, BV, MTT and PS differed by less than 1.8%, 2.9%, 2.5% and 2.6% across ASIR percentages. CV were 4.9%, 4.2%, 3.3% and 7.9%; rANOVA P values: 0.85, 0.62, 0.02 and 0.81 respectively. Conclusions: ASIR improves image noise and CNR without altering pCT parameters substantially. Keywords: Perfusion imaging, Multidetector computed tomography, Colorectal neoplasms, Computer-assisted image processing, Radiation dosage

  11. Vertebral uptake of Tc-99m macroaggregated albumin (MAA) with SPECT/CT occurring in superior vena cava obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma [Dept. of Nuclear Madicine, Royal Victoria Hospital, Montreal (Canada)

    2016-09-15

    A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.

  12. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  13. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  14. Myocardial perfusion imaging and coronary calcium scoring with a two-slice SPECT/CT system: can the attenuation map be calculated from the calcium scoring CT scan?

    Energy Technology Data Exchange (ETDEWEB)

    Wenning, Christian; Rahbar, Kambiz; Schober, Otmar; Stegger, Lars [University of Muenster, Department of Nuclear Medicine, Muenster (Germany); Vrachimis, Alexis; Schaefers, Michael [University of Muenster, Department of Nuclear Medicine, Muenster (Germany); University of Muenster, European Institute for Molecular Imaging, Muenster (Germany)

    2013-07-15

    Coronary artery calcium scoring can complement myocardial perfusion imaging (MPI). The purpose of this study was to evaluate the feasibility and accuracy of using the CalciumScore-CT derived from a combined SPECT/CT device also for SPECT attenuation correction (AC). The study group comprised 99 patients who underwent both post-stress and rest MPI using a two-slice SPECT/CT system. For AC, one of the two scans was accompanied by a CalciumScore-CT scan (CalciumScore-CTAC) and the other by a conventional spiral CT (AttenCorr-CT) scan (AttenCorr-CTAC). In 48 patients the CalciumScore-CT scan was acquired with the post-stress scan and the AttenCorr-CT scan with the rest scan, and in 51 patients the order was reversed. The accuracy of the images based on AC was determined qualitatively by consensus reading with respect to the clinical diagnoses as well as quantitatively by comparing the perfusion summed stress scores (SSS) and the summed rest scores (SRS) between attenuation-corrected and uncorrected images. In comparison to the uncorrected images CalciumScore-CTAC led to regional inaccuracies in 14 of 51 of studies (27.5 %) versus 12 of 48 studies (25 %) with AttenCorr-CTAC for the stress studies and in 5 of 48 (10 %) versus 1 of 51 (2 %) for the rest studies, respectively. This led to intermediate and definite changes in the final diagnosis (ischaemia and/or scarring) in 12 % of the studies (12 of 99) and in 7 % of the studies (7 of 99) with CalciumScore-CTAC and in 9 % of the studies (9 of 99) and 4 % of the studies (4 of 99) with AttenCorr-CTAC. Differences in SSS and SRS with respect to the uncorrected images were greater for the CalciumScore-CTAC images than for the AttenCorr-CTAC images ({Delta}SSS 4.5 {+-} 5.6 and 2.1 {+-} 4.4, p = 0.023; {Delta}SRS 4.2 {+-} 4.9 and 1.6 {+-} 3.2, p = 0.004, respectively). Using the same CT scan for calcium scoring and SPECT AC is feasible. Image interpretation must, however, include uncorrected images since CT-based AC relatively

  15. Detection of pulmonary fat embolism with dual-energy CT: an experimental study in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chun Xiang; Zhou, Chang Sheng; Zhao, Yan E.; Han, Zong Hong; Qi, Li; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Mangold, Stefanie; Ball, B.D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-04-15

    To evaluate the use of dual-energy CT imaging of the lung perfused blood volume (PBV) for the detection of pulmonary fat embolism (PFE). Dual-energy CT was performed in 24 rabbits before and 1 hour, 1 day, 4 days and 7 days after artificial induction of PFE via the right ear vein. CT pulmonary angiography (CTPA) and lung PBV images were evaluated by two radiologists, who recorded the presence, number, and location of PFE on a per-lobe basis. Sensitivity, specificity, and accuracy of CTPA and lung PBV for detecting PFE were calculated using histopathological evaluation as the reference standard. A total of 144 lung lobes in 24 rabbits were evaluated and 70 fat emboli were detected on histopathological analysis. The overall sensitivity, specificity and accuracy were 25.4 %, 98.6 %, and 62.5 % for CTPA, and 82.6 %, 76.0 %, and 79.2 % for lung PBV. Higher sensitivity (p < 0.001) and accuracy (p < 0.01), but lower specificity (p < 0.001), were found for lung PBV compared with CTPA. Dual-energy CT can detect PFE earlier than CTPA (all p < 0.01). Dual-energy CT provided higher sensitivity and accuracy in the detection of PFE as well as earlier detection compared with conventional CTPA in this animal model study. (orig.)

  16. WE-D-207-00: CT Lung Cancer Screening and the Medical Physicist: Moving Forward

    International Nuclear Information System (INIS)

    2015-01-01

    In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in

  17. Perfusion CT assessment of the colon and rectum: Feasibility of quantification of bowel wall perfusion and vascularization

    International Nuclear Information System (INIS)

    Khan, Sairah; Goh, Vicky; Tam, Emily; Wellsted, David; Halligan, Steve

    2012-01-01

    The aim was to determine the feasibility of vascular quantification of the bowel wall for different anatomical segments of the colorectum. Following institutional ethical approval and informed consent, 39 patients with colorectal cancer underwent perfusion CT. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface area product (PS) were assessed for different segments of the colorectum: ascending, transverse, descending colon, sigmoid, or rectum, that were distant from the tumor, and which were proven normal on contemporary colonoscopy, and subsequent imaging and clinical follow up. Mean (SD) for BF, BV, MTT and PS for the different anatomical colorectal segments were obtained and compared using a pooled t-test. Significance was at 5%. Assessment was not possible in 9 of 39 (23%) patients as the bowel wall was ≤5 mm precluding quantitative analysis. Forty-four segments were evaluated in the remaining 30 patients. Mean BF was higher in the proximal than distal colon: 24.0 versus 17.8 mL/min/100 g tissue; p = 0.009; BV, MTT and PS were not significantly different; BV: 3.46 versus 3.15 mL/100 g tissue, p = 0.45; MTT: 15.1 versus 18.3 s; p = 0.10; PS: 6.84 versus 8.97 mL/min/100 tissue, p = 0.13, respectively. In conclusion, assessment of bowel wall perfusion may fail in 23% of patients. The colorectum demonstrates segmental differences in perfusion.

  18. Clinical application of percutaneous needling lung abscess drairnage under CT guidance

    International Nuclear Information System (INIS)

    Hu Xiaokun; Wang Mingyou; Li Chenjun; Lv Dongfang; Li Xiaodong; Yu Zhaocun

    2004-01-01

    Objective: To discuss the clinical application of drainage for lung abscess by needle puncture under CT guidance. Methods: 18 cases of lung abscess were drainaged by needle puncture under CT guidance, including direct aspiration by puncture needle 1-3 times (n=8) and retaining drainage tube continuously (n=10). Results: 17 cases with this procedure were succeeded possessing success rate of 94.7%(17/18). The patients were followed up for 11-35 days with symptom relieving better obviously and the focus shrinkage or disappeared (n=16), the curative rate reached 88.9%(16/18). The main complication was pneumothorax with capacities of 30%(n=1). Conclusions: The curative course of lung abscess can be shortened greatly by percutaneous needling drainage under CT guidance with mild trauma. The procedure is simple with high successful rate and less complication. (authors)

  19. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. The role of perfusion lung scanning and diffusion capacity for early diagnosis of micro circulatory disturbances in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Petrova, D.; Shoshlov, P.; Hadjikostova, H.

    2002-01-01

    The development of chronic obstructive pulmonary disease (COPD) and the frequent inflammatory exacerbations with development of respiratory failure lead to changes in the micro circulatory and an increased risk of lung thrombotic and thromboembolic complication. The aim of the study was to establish the possibility of the perfusion lung scanning and diffusion capacity for early diagnosis of pulmonary micro circulatory disturbances in COPD with mild and moderate respiratory failure. 59 COPD patients were investigated. The data presented significant segmental disorders. Only in 5 (8.47%) of them the perfusion lung scintigrams were normal. In 23 of the patients, single-breath diffusing capacity (DICO) and its two components: membranous component (Dm) and capillary blood component (Vc) were determined. DICO was lower especially Vc the mean sign of micro circulatory disorders. A relationship between the degree of hypoxaemia and the changes found in the perfusion scintigraphy was found. Changes in the pulmonary lung scanning and in the diffusion capacity in COPD with mild respiratory failure seem to be an early diagnostic test. The early anticoagulant and desaggregant prevention may decrease the risk of thrombotic complications in the development of the disease. (authors)