WorldWideScience

Sample records for luminol-enhanced chemiluminescence plcl

  1. Study on Enhancement Principle and Stabilization for the Luminol-H2O2-HRP Chemiluminescence System.

    Directory of Open Access Journals (Sweden)

    Lihua Yang

    Full Text Available A luminol-H2O2-HRP chemiluminescence system with high relative luminescent intensity (RLU and long stabilization time was investigated. First, the comparative study on the enhancement effect of ten compounds as enhancers to the luminol-H2O2-HRP chemiluminescence system was carried out, and the results showed that 4-(imidazol-1-ylphenol (4-IMP, 4-iodophenol (4-IOP, 4-bromophenol (4-BOP and 4-hydroxy-4'-iodobiphenyl (HIOP had the best performance. Based on the experiment, the four enhancers were dissolved in acetone, acetonitrile, methanol, and dimethylformamide (DMF with various concentrations, the results indicated that 4-IMP, 4-IOP, 4-BOP and HIOP dissolved in DMF with the concentrations of 0.2%, 3.2%, 1.6% and 3.2% could get the highest RLU values. Subsequently, the influences of pH, ionic strength, HRP, 4-IMP, 4-IOP, 4-BOP, HIOP, H2O2 and luminol on the stabilization of the luminol-H2O2-HRP chemiluminescence system were studied, and we found that pH value, ionic strength, 4-IMP, 4-IOP, 4-BOP, HIOP, H2O2 and luminol have little influence on luminescent stabilization, while HRP has a great influence. In different ranges of HRP concentration, different enhancers should be selected. When the concentration is within the range of 0~6 ng/mL, 4-IMP should be selected. When the concentration of HRP ranges from 6 to 25 ng/mL, 4-IOP was the best choice. And when the concentration is within the range of 25~80 ng/mL, HIOP should be selected as the enhancer. Finally, the three well-performing chemiluminescent enhanced solutions (CESs have been further optimized according to the three enhancers (4-IMP, 4-IOP and HIOP in their utilized HRP concentration ranges.

  2. Enhancement effect of CdTe quantum dots-IgG bioconjugates on chemiluminescence of luminol-H2O2 system

    International Nuclear Information System (INIS)

    Kanwal, Shamsa; Traore, Zoumana; Zhao Chunfang; Su Xingguang

    2010-01-01

    In this paper we developed an entirely new and highly sensitive luminol-H 2 O 2 flow injection chemiluminescence system using the enhancement effect of CdTe quantum dots-IgG bioconjugates. Immunoglobulin G (IgG) as a kind of bio-molecule was conjugated to different sized CdTe semiconductor quantum dots (QDs). Using PL spectra and CL intensity profiles, it was found that chemiluminescence resonance energy transfer (CRET) was possibly occurring between CdTe-IgG bioconjugate and luminol. Under optimum conditions, increase of IgG concentration in CdTe-IgG bioconjugate resulted enhancing effect on CL intensity of luminol-H 2 O 2 system. Moreover quenching effects on CL intensity by addition of different proteases can construct turn off biosensor for these proteases with low detection limits and wide linear range. Furthermore, the effects of various organic and inorganic species on CdTe-IgG bioconjugates enhanced luminol-H 2 O 2 CL system were also studied in this paper.

  3. Automated determination of asulam by enhanced chemiluminescence using luminol/peroxidase system.

    Science.gov (United States)

    Sánchez, Francisco García; Díaz, Aurora Navas; Bracho, Visitación; Aguilar, Alfonso; Algarra, Manuel

    2009-01-01

    A flow injection system with chemiluminescence detection for the determination of asulam, enhancer of the system luminol-H(2)O(2)-horseradish peroxidase, is proposed. The method shows a moderate selectivity against other pesticides usually present in formulations of herbicides and in water. The procedure was applied to the determination of asulam in tap water samples and a recovery study was carried out in order to validate the method. The obtained results show acceptable recovery values (between 88.3 and 93.9%). The detection limit for asulam was 0.12 ng/mL. The precision of the method expressed as relative standard deviation was 1.55% (n = 8), at the 19 ng/mL level.

  4. Comparative study of ß-glucan induced respiratory burst measured by nitroblue tetrazolium assay and real-time luminol-enhanced chemiluminescence assay in common carp (Cyprinus carpio L.)

    DEFF Research Database (Denmark)

    Jiménez, Natalia Ivonne Vera; Pietretti, D.; Wiegertjes, G. F.

    2013-01-01

    kidney cells of carp. However, whereas the NBT assay was shown to detect the production of only superoxide anions, the real-time luminol-enhanced assay could detect the production of both superoxide anions and hydrogen peroxide. Only the chemiluminescence assay could reliably record the production of ROS......-point measurement based on the intracellular reduction of nitroblue tetrazolium (NBT) and a real-time luminol-enhanced assay based on the detection of native chemiluminescence. Both assays allowed for detection of dose-dependent changes in magnitude of the respiratory burst response induced by β-glucans in head...... on a real-time scale at frequent and continual time intervals for time course experiments, providing more detailed information on the respiratory burst response. The real-time chemiluminescence assay was used to measure respiratory burst activity in macrophage and neutrophilic granulocyte-enriched head...

  5. Effect of the luminol signal enhancer on the chemiluminescence intensity and kinetics

    International Nuclear Information System (INIS)

    Liang Yanli; Yu Fei; Yu Songcheng; Wu Yongjun; Zhang Hongquan; Qu Lingbo

    2012-01-01

    The novel p-phenol derivatives, 4-(1-imidazolyl)-phenol, 4-hydroxybiphenyl, 4-hydroxy-4′-iodobiphenyl were employed as highly potent signal enhancers of luminol-hydrogen peroxide (H 2 O 2 )-horseradish peroxidase (HRP) chemiluminescence (CL) system. The CL reaction conditions were optimized, and the enhancement characteristics of these enhancers were compared with each other. The employment of these molecules greatly affected important assay parameters. Practically, the use of a novel enhancer, even a slightly change of the structure (or concentration) of 4-substituted phenol derivative, could affect assay properties quite dramatically. Furthermore, the use of different enhancers in the luminol–H 2 O 2 –HRP system can affect not only the intensity of the CL signal, which is well known, but also its kinetics. The experiment data indicated that the stronger intensity was combined with a more rapid decrease of the CL signal. - Highlights: ► 4-IMP, 4-BIP and HIOP take on different signal enhancement and light kinetics. ► The employment of 4-BIP resulted in a significant improvement of the detection limit. ► The magnitude of the signal enhancement was about 2.5-fold in the same system.

  6. Highly luminescent S,N co-doped carbon quantum dots-sensitized chemiluminescence on luminol-H2 O2 system for the determination of ranitidine.

    Science.gov (United States)

    Chen, Jianqiu; Shu, Juan; Chen, Jiao; Cao, Zhiran; Xiao, An; Yan, Zhengyu

    2017-05-01

    S,N co-doped carbon quantum dots (N,S-CQDs) with super high quantum yield (79%) were prepared by the hydrothermal method and characterized by transmission electron microscopy, photoluminescence, UV-Vis spectroscopy and Fourier transformed infrared spectroscopy. N,S-CQDs can enhance the chemiluminescence intensity of a luminol-H 2 O 2 system. The possible mechanism of the luminol-H 2 O 2 -(N,S-CQDs) was illustrated by using chemiluminescence, photoluminescence and ultraviolet analysis. Ranitidine can quench the chemiluminescence intensity of a luminol-H 2 O 2 -N,S-CQDs system. So, a novel flow-injection chemiluminescence method was designed to determine ranitidine within a linear range of 0.5-50 μg ml -1 and a detection limit of 0.12 μg ml -1 . The method shows promising application prospects. Copyright © 2016 John Wiley & Sons, Ltd.

  7. The chemiluminescence of luminol in aqueous solutions, a pulse radiolytic study

    International Nuclear Information System (INIS)

    Lind, J.

    1980-01-01

    The mechanism of chemiluminescence was studied when the luminol radical and superoxide were generated simultaneously. Hydroperoxide was formed at the first reaction step with a pKa value between 11 and 12. The dissociated form was found to undergo a monomolecular reaction leading to light generation and having a rate constant > 2 x 10 5 s -1 . The protonated form had the rate constant of approx. 2000 s -1 and formed a product which absorbed around 390 nm without light emission. The reaction of the two-electron oxidation product of luminol, 5-aminophthalazine-1, 4 dione (azaquinone), with hydrogenperoxide was stoichiometrically equivalent to the recombination of superoxide with the luminol radical. The pulseradiolytic generation of the chlorinedioxide radical ClO 2 in aqueous solution of sodium chlorite is described, and the oxidation of luminol by ClO 2 in two steps is reported: 1. Radical adducts are formed. 2. The reaction of ClO 2 x radical with the adduct to form azaquinone. The chemiluminescent reaction between the azaquinone and hydrogenperoxide consists of a second order reaction between HO 2 and the azaquinone to form a hydroperoxide followed by a monomolecular rearrangement of the dissociated form of the latter. Its acidbase equilibrium has a pKa of 10.6. A nitrogencentered structure is ascribed to the hydroperoxide formed by cross-recombination of the luminolradical and superoxide while the reaction between HO 2 and azaquinone yields a carboncentered hydroperoxide. The existence of two different emitters is evidenced by the following observations. 1. A slight difference in chemiluminescence spectra. 2. The formation of an endproduct with pKa approx. 10.2 in the luminolradical superoxide system. 3. The formation of an endproduct which acts as an efficient radial scavenger in the luminol radical superoxide system. (G.B.)

  8. Enhancing and inhibiting effects of aromatic compounds on luminol-dimethylsulfoxide-OH(-) chemiluminescence and determination of intermediates in oxidative hair dyes by HPLC with chemiluminescence detection.

    Science.gov (United States)

    Zhou, Jian; Xu, Hong; Wan, Guo-Hui; Duan, Chun-Feng; Cui, Hua

    2004-10-08

    The effect of 36 aromatic compounds on the luminol-dimethylsulfoxide-OH(-) chemiluminescence (CL) was systematically studied. It was found that dihydroxybenzenes, and ortho- and para-substituted aminophenols and phenylenediamines inhibited the CL and phenols with three or more than three hydroxyls except phloroglucin tended to enhance the CL. The CL inhibition and enhancement was proposed to be dependent on whether superoxide anion radical (O(2)(-)) was competitively consumed by compounds in the CL system. Trihydroxybenzenes were capable of generating superoxide anion radical, leading to the CL enhancement, whereas dihydroxybenzenes were superoxide anion radical scavenger, causing the CL inhibition. Based on the inhibited CL, a novel method for the simultaneous determination of p-phenylenediamine, o-phenylenediamine, p-aminophenol, o-aminophenol, resorcinol and hydroquinone by high-performance liquid chromatography coupled with chemiluminescence detection was developed. The method has been successfully applied to determine intermediates in oxidative hair dyes and wastewater of shampooing after hair dyed.

  9. Development of luminol-N-hydroxyphthalimide chemiluminescence system for highly selective and sensitive detection of superoxide dismutase, uric acid and Co2.

    Science.gov (United States)

    Saqib, Muhammad; Qi, Liming; Hui, Pan; Nsabimana, Anaclet; Halawa, Mohamed Ibrahim; Zhang, Wei; Xu, Guobao

    2018-01-15

    N-hydroxyphthalimide (NHPI), a well known reagent in organic synthesis and biochemical applications, has been developed as a stable and efficient chemiluminescence coreactant for the first time. It reacts with luminol much faster than N-hydroxysuccinimide, eliminating the need of a prereaction coil used in N-hydroxysuccinimide system. Without using prereaction coil, the chemiluminescence peak intensities of luminol-NHPI system are about 102 and 26 times greater than that of luminol-N-hydroxysuccinimide system and classical luminol-hydrogen peroxide system, respectively. The luminol-NHPI system achieves the highly sensitive detection of luminol (LOD = 70pM) and NHPI (LOD = 910nM). Based on their excellent quenching efficiencies, superoxide dismutase and uric acid are sensitively detected with LODs of 3ng/mL and 10pM, respectively. Co 2+ is also detected a LOD of 30pM by its remarkable enhancing effect. Noteworthily, our method is at least 4 orders of magnitude more sensitive than previously reported uric acid detection methods, and can detect uric acid in human urine and Co 2+ in tap and lake water real samples with excellent recoveries in the range of 96.35-102.70%. This luminol-NHPI system can be an important candidate for biochemical, clinical and environmental analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. A turn-on chemiluminescence biosensor for selective and sensitive detection of adenosine based on HKUST-1 and QDs-luminol-aptamer conjugates.

    Science.gov (United States)

    Lin, Yanna; Dai, Yuxue; Sun, Yuanling; Ding, Chaofan; Sun, Weiyan; Zhu, Xiaodong; Liu, Hao; Luo, Chuannan

    2018-05-15

    In this work, HKUST-1 and QDs-luminol-aptamer conjugates were prepared. The QDs-luminol-aptamer conjugates can be adsorbed by graphene oxide through π-π conjugation. When the adenosine was added, the QDs-luminol-aptamer conjugates were released from magnetic graphene oxide (MGO), the chemiluminescent switch was turned on. It was reported that HKUST-1 can catalyze the chemiluminescence reaction of luminol-H 2 O 2 system in an alkaline medium, and improve the chemiluminescence resonance energy transfer (CRET) between chemiluminescence and QDs indirectly. Thus, the adenosine can be detected sensitively. Based on this phenomenon, the excellent platform for detection of adenosine was established. Under the optimized conditions, the linear detection range for adenosine was 1.0 × 10 -12 -2.2 × 10 -10 mol/L with a detection limit of 2.1 × 10 -13 mol/L. The proposed method was successfully used for adenosine detection in biological samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Long-term chemiluminescence signal is produced in the course of luminol oxidation catalyzed by enhancer-independent peroxidase purified from Jatropha curcas leaves.

    Science.gov (United States)

    Duan, Peipei; Cai, Feng; Luo, Yongting; Chen, Yangxi; Zou, Shujuan

    2015-09-01

    Isoenzyme c of horseradish peroxidase (HRP-C) is widely used in enzyme immunoassay combined with chemiluminescence (CL) detection. For this application, HRP-C activity measurement is usually based on luminol oxidation in the presence of hydrogen peroxide (H2O2). However, this catalysis reaction was enhancer dependent. In this study, we demonstrated that Jatropha curcas peroxidase (JcGP1) showed high efficiency in catalyzing luminol oxidation in the presence of H2O2. Compared with HRP-C, the JcGP1-induced reaction was enhancer independent, which made the enzyme-linked immunosorbent assay (ELISA) simpler. In addition, the JcGP1 catalyzed reaction showed a long-term stable CL signal. We optimized the conditions for JcGP1 catalysis and determined the favorable conditions as follows: 50 mM Tris buffer (pH 8.2) containing 10 mM H2 O2, 14 mM luminol and 0.75 M NaCl. The optimum catalysis temperature was 30°C. The detection limit of JcGP1 under optimum condition was 0.2 pM. Long-term stable CL signal combined with enhancer-independent property indicated that JcGP1 might be a valuable candidate peroxidase for clinical diagnosis and enzyme immunoassay with CL detection. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Electrogenerated chemiluminescence of luminol using low-cost electrodes

    International Nuclear Information System (INIS)

    Salgado, Guillermo; Navarrete, Jose; Bustos, Carlos; Sanchez, Cristian; Ugarte, Ricardo

    2006-01-01

    The purpose of the study was to observe eletrogenerated chemiluminescence (ECL) of luminol using different materials as electrodes such as wires, nails, coins, razor blades, etc. Based on the experimental observations and the mechanisms proposed in the literature, students should be capable of analyzing their results in order to understand the phenomena studied. Students could then elaborate a mechanism of action consistent with the experimental results which could rationalize the formation of intermediates in the reaction and the dependence of ECL on solution pH in addition to other points of interest. (author)

  13. A novel luminol chemiluminescent method catalyzed by silver/gold alloy nanoparticles for determination of anticancer drug flutamide.

    Science.gov (United States)

    Chaichi, Mohammad Javad; Azizi, Seyed Naser; Heidarpour, Maryam

    2013-12-01

    It was found that silver/gold alloy nanoparticles enhance the chemiluminescence (CL) of the luminol-H2O2 system in alkaline solution. The studies of UV-Vis spectra, CL spectra, effects of concentrations luminol, hydrogen peroxide and silver/gold alloy nanoparticles solutions were carried out to explore the CL enhancement mechanism. Flutamide was found to quench the CL signals of the luminol-H2O2 reaction catalyzed by silver/gold alloy nanoparticles, which made it applicable for the determination of flutamide. Under the optimum conditions, the CL intensity is proportional to the concentration of the flutamide in solution over the range 5.0 × 10(-7) to 1.0 × 10(-4)mol L(-1). Detection limit was obtained 1.2 × 10(-8)mol L(-1)and the relative standard deviation (RSD) γ5%. This work is introduced as a new method for the determination of flutamide in commercial tablets. Box-Behnken experimental design is applied to investigate and validate the CL measurement parameters. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Application of Box-Behnken design in the optimization of catalytic behavior of a new mixed chelate of copper (II) complex in chemiluminescence reaction of luminol

    International Nuclear Information System (INIS)

    Khajvand, Tahereh; Chaichi, Mohammad Javad; Nazari, OmLeila; Golchoubian, Hamid

    2011-01-01

    In this work, we observed an enhancement of chemiluminescence (CL) emission of luminol when a new mixed chelate of copper complex (N-(2-(2-aminoethylamino)ethyl)-1H-pyrrole-2-carboxamide-Cu(II)) was mixed with a solution containing luminol in methanol/water. The Box-Behnken design matrix and response surface methodology (RSM) have been applied to design the experiments to evaluate the interactive effects of the three most important operating variables-luminol (10 -4 -10 -2 M), fluorescein (10 -5 -10 -3 M) and hydrogen peroxide (1-3 M) concentrations on the CL emission of luminol. The total 15 experiments were conducted in the present study towards the construction of a quadratic model. Independent variables luminol and hydrogen peroxide have significant value P F less than 0.0500 indicate that model terms are significant for the CL emission of luminol. The regression equation coefficients were calculated and the data fitted to a second-order polynomial equation for CL emission of luminol. The new introduced inorganic catalyst of luminol CL reaction can be effect more than that of the common ones such as potassium hexacyanoferrate (III) and copper (II) acetate. - Research highlights: → In this study we introduce a new mixed chelate of copper complex as a catalyst of luminol chemiluminescence (CL) reaction. → The copper complex (N-(2-(2-aminoethylamino)ethyl)-1H-pyrrole-2-carboxamide-Cu(II)) catalyst luminol reaction more than that of copper acetate and potassium hexacyanoferrate (III). → The Box-Behnken design matrix and response surface methodology are used for prediction of CL intensity of luminol. → There are good correlation between experimental and expected CL intensity that predicted by the theoretical model. → Fluorescein used as a fluorescer in the luminol CL reaction in presence of the new catalyst.

  15. Luminol Chemiluminescence Catalyzed by Silver Nanoparticles for the Sensitive Determination of Penicillamine

    Directory of Open Access Journals (Sweden)

    Fakhr Eldin O. Suliman

    2018-01-01

    Full Text Available A sequential injection method for the determination of penicillamine (PA was developed based on quenching the chemiluminescence generated by oxidation of luminol by hydrogen peroxide in presence of silver nanoparticles (AgNPs. The chemiluminescence (CL of the reaction was found to greatly enhance in presence of AgNPs due to the increased catalyst surface area. The method was sensitive and found suitable for analysis of penicillamine in pharmaceutical preparations. Linear calibration curve is obtained in the range 0.2-1.0 mg mL-1 with a relative standard deviation less than 2%. A recovery percent of 102.3 ±0.2 was obtained with the tablets matrix indicating reasonable selectivity of the method for PA in tablets. The mechanism of quenching of the CL reaction was investigated by UV-Visible spectroscopy and transmission electron microscopy as well as by theoretical calculations using DFT-B3LYP method. The covalent attachment of PA to the AgNPs triggers aggregation of the particles thereby diminishing the surface significantly. The method was applied for the assay of PA in pharmaceutical preparations.

  16. Comparative study of β-glucan induced respiratory burst measured by nitroblue tetrazolium assay and real-time luminol-enhanced chemiluminescence assay in common carp (Cyprinus carpio L.).

    Science.gov (United States)

    Vera-Jimenez, N I; Pietretti, D; Wiegertjes, G F; Nielsen, M E

    2013-05-01

    The respiratory burst is an important feature of the immune system. The increase in cellular oxygen uptake that marks the initiation of the respiratory burst is followed by the production of reactive oxygen species (ROS) such as superoxide anion and hydrogen peroxide which plays a role in the clearance of pathogens and tissue regeneration processes. Therefore, the respiratory burst and associated ROS constitute important indicators of fish health status. This paper compares two methods for quantitation of ROS produced during the respiratory burst in common carp: the widely used, single-point measurement based on the intracellular reduction of nitroblue tetrazolium (NBT) and a real-time luminol-enhanced assay based on the detection of native chemiluminescence. Both assays allowed for detection of dose-dependent changes in magnitude of the respiratory burst response induced by β-glucans in head kidney cells of carp. However, whereas the NBT assay was shown to detect the production of only superoxide anions, the real-time luminol-enhanced assay could detect the production of both superoxide anions and hydrogen peroxide. Only the chemiluminescence assay could reliably record the production of ROS on a real-time scale at frequent and continual time intervals for time course experiments, providing more detailed information on the respiratory burst response. The real-time chemiluminescence assay was used to measure respiratory burst activity in macrophage and neutrophilic granulocyte-enriched head kidney cell fractions and total head kidney cell suspensions and proved to be a fast, reliable, automated multiwell microplate assay to quantitate fish health status modulated by β-glucans. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Flow-based determination of methionine in pharmaceutical formulations exploiting TGA-capped CdTe quantum dots for enhancing the luminol-KIO{sub 4} chemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Min, E-mail: mzhou8367@sina.com [Key Laboratory of Eco-Environment-Related Polymer Materials, Ministry of Education, Key Laboratory of Polymer Materials of Gansu Province, Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); Wang, Ailian [Key Laboratory of Eco-Environment-Related Polymer Materials, Ministry of Education, Key Laboratory of Polymer Materials of Gansu Province, Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); Jiuquan Enviromental Protection Bureau, Jiuquan 735000 (China); Li, Cong; Luo, Xiaowei; Ma, Yongjun [Key Laboratory of Eco-Environment-Related Polymer Materials, Ministry of Education, Key Laboratory of Polymer Materials of Gansu Province, Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China)

    2017-03-15

    A novel flow-injection chemiluminescence method (FI-CL) was established for the determination of methionine in this paper, based on its strong enhancement on CL intensity of the luminol-KIO{sub 4} system catalyzed by thioglycolic acid-capped CdTe quantum dots in alkaline media. Under the optimized conditions, the relative CL intensity was in proportion to methionine concentration in the range from 1.0×10{sup −8} to 1.0×10{sup −5} g mL{sup −1} with a detection limit of 6.6×10{sup −9} g mL{sup −1} (3σ). The relative standard deviation (RSD) of the CL intensity for 1.0×10{sup −6} g mL{sup −1} standard methionine solution was 0.97% (n=11). The proposed method was successfully applied to determine methionine in commercial pharmaceutical formulations with recoveries between 98.0% and 101.9%. The possible CL mechanism was discussed as well. - Graphical abstract: Methionine in commercial pharmaceutical formulations was determined by flow-injection chemiluminescence and the possible chemiluminescence mechanism was discussed as well.

  18. A novel chemiluminescence assay of organophosphorous pesticide quinalphos residue in vegetable with luminol detection

    Directory of Open Access Journals (Sweden)

    Yao Xin

    2010-06-01

    Full Text Available Abstract Background Organophosphorous pesticides are the most popular pesticides used in agriculture. As acetylcholinesterase inhibitors, organophosphorous pesticides are toxic organic chemicals. The control and detection of organophosphorous pesticide residue in food, water, and environment therefore plays a very important role in maintaining physical health. A sensitive, rapid, simple chemiluminescence(CL method has been developed for the determination of quinalphos based on the reaction of quinalphos with luminol-H2O2 in an alkaline medium. The method has been applied to detection of quinalphos in vegetable samples with satisfactory results. Results The CL method for the determination of organophosphorous pesticide quinalphos is based on the phenomenon that quinalphos can apparently enhance the CL intensity of the luminol-H2O2 system. The optimal conditions were: luminol concentration 5.0 × 10-4 mol/L, H2O2 concentration 0.05 mol/L.pH value 13. In order to restrain the interference from metal ions, 1.0 × 10-3 mol/L of EDTA was added to the luminol solution. The possible mechanism was proposed. Conclusion Under the optimum reaction conditions, CL was linear with the concentration of quinalphos in the range of 0.02 μg/mL -1.0 μg/mL and the detection limit was 0.0055 μg/mL (3σ. This method has been successfully applied to the detection of quinalphos in vegetable samples. According to the experimental data, the average recoveries for quinalphos in cherry tomato and green pepper 97.20% and 90.13%. Meanwhile, the possible mechanism was proposed.

  19. Effect of gold nanoparticle as a novel nanocatalyst on luminol-hydrazine chemiluminescence system and its analytical application

    International Nuclear Information System (INIS)

    Safavi, A.; Absalan, G.; Bamdad, F.

    2008-01-01

    In this work the catalytic role of unsupported gold nanoparticles on the luminol-hydrazine reaction is investigated. Gold nanoparticles catalyze the reaction of hydrazine and dissolved oxygen to generate hydrogen peroxide and also catalyze the oxidation of luminol by the produced hydrogen peroxide. The result is an intense chemiluminescence (CL) due to the excited 3-aminophthalate anion. In the absence of gold nanoparticles no detectable CL was observed by the reaction of luminol and hydrazine unless an external oxidant is present in the system. The size effect of gold nanoparticles on the CL intensity was investigated. The most intensive CL signals were obtained with 15-nm gold nanoparticles. UV-vis spectra and transmission electron microscopy studies were used to investigate the CL mechanism. The luminol and hydroxide ion concentration, gold nanoparticles size and flow rate were optimized. The proposed method was successfully applied to the determination of hydrazine in boiler feed water samples. Between 0.1 and 30 μM of hydrazine could be determined with a detection limit of 30 nM

  20. Flow Injection Photosensitized Chemiluminescence of Luminol with Cu(II-Rose Bengal: Mechanistic Approach and Vitamin A and C Determination

    Directory of Open Access Journals (Sweden)

    Muhammad Asgher

    2014-01-01

    Full Text Available Rose Bengal photosensitized flow injection chemiluminescence method is reported using luminol-Cu(II for the determination of vitamins A and C in pharmaceutical formulations. The reaction is based on the enhancement effect of analyte in the production of anion radicals of Rose Bengal (RB•− which rapidly interact with dissolved oxygen and generate superoxide anions radicals (O2•− and hydrogen peroxide (H2O2. Highly reactive hydroxyl radicals (•OH were produced via dismutation of H2O2 by catalyst (Cu2+. The generated superoxide anions radicals and hydroxyl radicals thus oxidize luminol in alkaline medium to generate strong chemiluminescence. The limit of detection (3s of the blank, n=6 of vitamins A and C and RB was found to be 0.008, 0.005, and 0.05 μg mL−1, respectively. The sample throughput of 70 h−1 for vitamins A and C and 30 h−1 for RB was found. Calibration curve was linear in the range of 0.05–15, 0.01–20, and 0.1–50 μg mL−1 for vitamins A and C and RB, respectively, with relative standard deviations (RSDs; n=3 in the range 1.6–3.6%. The method was successfully applied to pharmaceutical formulations and the results obtained were in good agreement with the labeled values.

  1. Luminol functionalized gold nanoparticles as colorimetric and chemiluminescent probes for visual, label free, highly sensitive and selective detection of minocycline

    Science.gov (United States)

    He, Yi; Peng, Rufang

    2014-11-01

    In this work, luminol functionalized gold nanoparticles (LuAuNPs) were used as colorimetric and chemiluminescent probes for visual, label free, sensitive and selective detection of minocycline (MC). The LuAuNPs were prepared by simple one-pot reduction of HAuCl4 with luminol, which exhibited a good chemiluminescence (CL) activity owing to the presence of luminol molecules on their surface and surface plasmon resonance absorption. In the absence of MC, the color of LuAuNPs was wine red and their size was relatively small (˜25 nm), which could react with silver nitrate, producing a strong CL emission. Upon the addition of MC at acidic buffer solutions, the electrostatic interaction between positively charged MC and negatively charged LuAuNPs caused the aggregation of LuAuNPs, generating a purple or blue color. Simultaneously, the aggregated LuAuNPs did not effectively react with silver nitrate, producing a weak CL emission. The signal change was linearly dependent on the logarithm of MC concentration in the range from 30 ng to 1.0 μg for colorimetric detection and from 10 ng to 1.0 μg for CL detection. With colorimetry, a detection limit of 22 ng was achieved, while the detection limit for CL detection modality was 9.7 ng.

  2. Luminol functionalized gold nanoparticles as colorimetric and chemiluminescent probes for visual, label free, highly sensitive and selective detection of minocycline

    International Nuclear Information System (INIS)

    He, Yi; Peng, Rufang

    2014-01-01

    In this work, luminol functionalized gold nanoparticles (LuAuNPs) were used as colorimetric and chemiluminescent probes for visual, label free, sensitive and selective detection of minocycline (MC). The LuAuNPs were prepared by simple one-pot reduction of HAuCl 4 with luminol, which exhibited a good chemiluminescence (CL) activity owing to the presence of luminol molecules on their surface and surface plasmon resonance absorption. In the absence of MC, the color of LuAuNPs was wine red and their size was relatively small (∼25 nm), which could react with silver nitrate, producing a strong CL emission. Upon the addition of MC at acidic buffer solutions, the electrostatic interaction between positively charged MC and negatively charged LuAuNPs caused the aggregation of LuAuNPs, generating a purple or blue color. Simultaneously, the aggregated LuAuNPs did not effectively react with silver nitrate, producing a weak CL emission. The signal change was linearly dependent on the logarithm of MC concentration in the range from 30 ng to 1.0 μg for colorimetric detection and from 10 ng to 1.0 μg for CL detection. With colorimetry, a detection limit of 22 ng was achieved, while the detection limit for CL detection modality was 9.7 ng. (paper)

  3. Self-Catalyzing Chemiluminescence of Luminol-Diazonium Ion and Its Application for Catalyst-Free Hydrogen Peroxide Detection and Rat Arthritis Imaging.

    Science.gov (United States)

    Zhao, Chunxin; Cui, Hongbo; Duan, Jing; Zhang, Shenghai; Lv, Jiagen

    2018-02-06

    We report the unique self-catalyzing chemiluminescence (CL) of luminol-diazonium ion (N 2 + -luminol) and its analytical potential. Visual CL emission was initially observed when N 2 + -luminol was subjected to alkaline aqueous H 2 O 2 without the aid of any catalysts. Further experimental investigations found peroxidase-like activity of N 2 + -luminol on the cleavage of H 2 O 2 into OH • radical. Together with other experimental evidence, the CL mechanism is suggested as the activation of N 2 + -luminol and its dediazotization product 3-hydroxyl luminol by OH • radical into corresponding intermediate radicals, and then further oxidation to excited-state 3-N 2 + -phthalic acid and 3-hydroxyphthalic acid, which finally produce 415 nm CL. The self-catalyzing CL of N 2 + -luminol provides us an opportunity to achieve the attractive catalyst-free CL detection of H 2 O 2 . Experiments demonstrated the 10 -8 M level detection sensitivity to H 2 O 2 as well as to glucose or uric acid if presubjected to glucose oxidase or uricase. With the exampled determination of serum glucose and uric acid, N 2 + -luminol shows its analytical potential for other analytes linking the production or consumption of H 2 O 2 . Under physiological condition, N 2 + -luminol exhibits highly selective and sensitive CL toward 1 O 2 among the common reactive oxygen species. This capacity supports the significant application of N 2 + -luminol for detecting 1 O 2 in live animals. By imaging the arthritis in LEW rats, N 2 + -luminol CL is demonstrated as a potential tool for mapping the inflammation-relevant biological events in a live body.

  4. Assay of picogram level isocarbophos residue on tangerines and oranges with luminol-albumin chemiluminescence system.

    Science.gov (United States)

    Chen, Donghua; Song, Zhenghua; Lv, Hairu

    2012-12-15

    A sensitive flow injection-chemiluminescence (FI-CL) method for the determination of isocarbophos (ICP) residue on tangerines and oranges was proposed. It was found that the CL intensity from luminol-albumin CL reaction could be obviously quenched in the presence of ICP and the decrease in CL intensity was proportional to the logarithm of ICP concentrations ranging from 1.0 to 1000 pmol L(-1), giving the limit of detection of 0.3 pmol L(-1) (3σ). The proposed procedure was successfully applied to the determination of ICP residue on tangerines and oranges with recoveries varying from 92.0 to 111.0% and RSDs less than 5.0%. The possible CL mechanism of luminol-albumin-ICP reaction was discussed, and ICP to albumin's binding constant (K(D)=1.00 × 10(6) L mol(-1)) and the number of binding sites (n=1.00) were given by the homemade FI-CL model. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Effect of the dimetilsulfoxido in the response chemiluminescent and the consumption of oxygen of neutrophils activated human

    International Nuclear Information System (INIS)

    Garcia, J.

    2001-01-01

    Dimethylsulfoxide (DMSO), a hydroxyl radical scavenger, exerted a dose dependent inhibition on the luminol and lucigenin-enhanced chemiluminescent responses of human neutrophils activated with soluble and particulate stimulants. DMSO inhibition of the luminol chemiluminescense induced by calcium ionophore A23187 was probably due to OH scavenging, whereas inhibition of the lucigenin chemiluminescence suggested DMSO negatively affects the NADPH-dependent membrane oxidase of neutrophils. In agreement with this, DMSO moderately inhibited O2 consumption in PMN suspensions stimulated with chemotactic peptide and opsonized zymosan-induced luminol chemiluminescense was observed only when added before or in conjunction with stimulants, whereas A23187-induced chemiluminescense was inhibited by DMSO regardless of time of addition. Washing of DMSO-treated PMN resulted in increased luminol enhanced chemiluminescense in response to chemotactic peptide and opsonized zymosan. This is consistent with the idea that DMSO may be interfering with activation of the membrane subunits of the oxidase by translocation and docking of the cytoplasmic, regulatory subunits. These data imply that DMSO inhibits neutrophil chemiluminescense both by OH scavenging and interfering with oxidase activation. Key words:Dimethylsulfoxide, chemiluminescent, luminol, lucigenin,neutrophils [es

  6. A new luminol chemiluminescence sensor for glucose based on pH-dependent graphene oxide.

    Science.gov (United States)

    Hao, Minjia; Liu, Na; Ma, Zhanfang

    2013-08-07

    In this study, graphene oxide (GO) was found to catalyze the luminol-O2 reaction, which yielded a novel chemiluminescence (CL). Remarkably, the CL emission could be tuned by modulating the pH of the GO dispersion. Transmission electron microscopy, CL spectra, electron spin resonance spectra studies were carried out to investigate the CL mechanism. The results indicate that the CL emission was attributed to the intrinsic catalytic effect of GO acting as the radical generation proliferators and electron transfer accelerators. Based on the GO catalyzed luminol-O2 system, we successfully developed a new CL sensor to detect glucose. Under the optimized conditions, glucose could be assayed in the range of 0.05 mM to 5 mM with a detection limit of 0.044 mM. For the detection of clinical serum samples, it is well consistent with the data determined by commercially available method in hospital, indicating that the new CL method provides a possible application for the detection of glucose in clinical diagnostics.

  7. Luminol-dependent chemiluminescence in antibody-sensitized neutrophils stimulated with protein A-bearing staphylococci.

    Science.gov (United States)

    Nishihara, S; Seki, K; Ikigai, H; Masuda, S

    1988-01-01

    When mouse polymorphonuclear leukocytes (PMNs) sensitized with rabbit antibody to mouse Ehrlich ascites tumor cells were stimulated by Staphylococcus aureus Cowan I cells, a conspicuous luminol-dependent chemiluminescence was observed in the absence of opsonin. The profile of the chemiluminescence (CL) response evoked by staphylococcal cells from antibody-sensitized PMNs had two peaks. An initial peak, observed within 1 min after stimulation, was sharp and high and a second peak, observed about 5 min after stimulation, was low and extended. The CL response of antibody-sensitized PMNs stimulated by S. aureus Cowan I cells was dose-dependently blocked by preincubation with soluble SpA. Cells of a mutant derived from S. aureus Cowan I strain with trace amounts of cell-bound SpA failed to stimulate the antibody-sensitized PMNs to generate the CL response. The antibody-sensitized PMNs were found to phagocytize SpA-bearing S. aureus cells even in the absence of opsonic serum. These results suggest that the observation presented here might provide a useful tool for the investigation of CL response of PMNs.

  8. СHANGES IN PARAMETERS OF LUMINOL-DEPENDENT AND LUCIGENIN-DEPENDENT CHEMILUMINESCENCE OF PERIPHERAL BLOOD NEUTROPHILS IN PATIENTS WITH BLADDER CANCER IN THE DISEASE DYNAMICS

    Directory of Open Access Journals (Sweden)

    L. M. Kurtasova

    2015-01-01

    Full Text Available The study deals with parameters of luminol-dependent and lucigenin-dependent chemiluminescence (CL of peripheral blood neutrophils from patients with bladder cancer (BC prior to surgical treatment. We examined sixty patients (45 to 55 years old with advanced bladder cancer (TNM prior to the operation, and forty-six patients at 10 days after surgical treatment. A control group consisted of 56 healthy donors. Luminol-dependent and lucigenin-dependent chemiluminescence of blood neutrophils was assessed according to De Sole et al. (1983. Chemiluminescence assays of peripheral blood neutrophils from the patients with bladder cancer revealed changes in production of reactive oxygen species (ROS, both for initial stage of oxidation reaction, and total level of active oxygen radicals. We have found disturbed values of primary-to-secondary ROS ratio in the cells. In the patients with bladder cancer, some changes in oxidative metabolism of the blood neutrophils have been registered. These alterations may play an important role in promotion of potential effector cell functions, thus, probably, affecting the whole-scale development of a cytopathic effect exerted by neutrophilic granulocytes. 

  9. Applications of chemiluminescence to bacterial analysis

    Science.gov (United States)

    Searle, N. D.

    1975-01-01

    Luminol chemiluminescence method for detecting bacteria was based on microbial activation of the oxidation of the luminol monoanion by hydrogen peroxide. Elimination of the prior lysing step, previously used in the chemiluminescence technique, was shown to improve considerably the reproducibility and accuracy of the method in addition to simplifying it. An inexpensive, portable photomultiplier detector was used to measure the maximum light intensity produced when the sample is added to the reagent. Studies of cooling tower water show that the luminol chemiluminescence technique can be used to monitor changes in viable cell population both under normal conditions and during chlorine treatment. Good correlation between chemiluminescence and plate counts was also obtained in the analysis of process water used in paper mills. This method showed good potential for monitoring the viable bacteria populations in activated sludge used in waste treatment plants to digest organic matter.

  10. MIL-53(Fe) MOF-mediated catalytic chemiluminescence for sensitive detection of glucose.

    Science.gov (United States)

    Yi, Xueling; Dong, Wenfei; Zhang, Xiaodan; Xie, Jianxin; Huang, Yuming

    2016-12-01

    Various analytical applications of metal-organic frameworks (MOFs) have been rapidly developed in the past few years. However, the employment of MOFs as catalysts in chemiluminescence (CL) analysis is rare. Here, for the first time, we found that MIL-53(Fe) MOFs could significantly enhance the CL of luminol in the presence of H 2 O 2 in an alkaline medium. The CL intensity in the luminol-H 2 O 2 -MIL-53(Fe) system was about 20 times higher than that in the luminol-H 2 O 2 system. Moreover, the XRD pattern of MIL-53(Fe) after CL reaction was almost the same as that of the original MIL-53(Fe), confirming the catalytic role of MIL-53(Fe) in the luminol-H 2 O 2 -MIL-53(Fe) system. The possible mechanism behind the enhancing phenomenon was discussed based on the results from the CL spectra, FL probe experiments, and active oxygen species measurements. By coupling with the glucose oxidase-based catalytic oxidation reaction, a sensitive and selective CL method was developed for the detection of glucose. There is a linear relationship between the logarithm of CL intensity and the logarithm of glucose concentration in the range from 0.1 to 10 μM, and a detection limit of 0.05 μM (S/N = 3) is obtained. The proposed method has been applied to the determination of glucose in human serum samples with satisfactory results. Graphical abstract MIL-53(Fe) MOFs are found to greatly enhance the chemiluminescence emission of the luminol-H 2 O 2 system, and this finding resulted in a new chemiluminescence method for biosensing of glucose when coupled with the glucose oxidase.

  11. Formation of Hydrogen Peroxide by Electrochemical Reduction of Molecular Oxygen using Luminol Chemiluminescence

    International Nuclear Information System (INIS)

    Rana, Sohail

    2005-01-01

    Formation of hydrogen peroxide by electrochemical reduction of molecular oxygen was examined by measuring luminol chemiluminescence and absorption spectrum using flow-injection method. Ferryl porphyrin is widely accepted as responsible species to stimulate the emission in hydrogen peroxide/ iron porphyrin/ luminol system. Emission was observed under cathodic potentials (0.05V at pH2.0 and -0.3V at pH11.0) by the electrochemical reduction of aerated electrolytes solution but emission was observed at anodic potentials. Iron porphyrin solution was added at down stream of the working electrode and was essential for the emission. Removal of the dissolved molecular oxygen resulted in the decrease of emission intensity by more than 70%. In order to examine the life time of reduced active species, delay tubes were introduced between working electrode Fe TMPyP inlet. Experimental results suggested the active species were stable for quite a long period. The emission was quenched considerably (>90%) when hydroperoxy was added at the down stream of working electrode whereas the Superoxide dismutase (SOD) had little effect and mannitol had no effect. The spectra at reduction potential under aerated condition were shifted to the longer wavelength (>430nm) compared to the original spectrum of Fe TMPyP (422nm), indicating that the ferryl species were mixed to some extent. These observations lead to the conclusion that hydrogen peroxide was produced first by electrochemical reduction of molecular oxygen which then converted Fe TMPyP into O=FeTMPyP to activate luminol. Comparing emission intensities with the reference experiments, the current efficiencies for the formation of hydrogen peroxide were estimated as about 30-65% in all over the pH range used. (author)

  12. Graphene-based chemiluminescence resonance energy transfer for homogeneous immunoassay.

    Science.gov (United States)

    Lee, Joon Seok; Joung, Hyou-Arm; Kim, Min-Gon; Park, Chan Beum

    2012-04-24

    We report on chemiluminescence resonance energy transfer (CRET) between graphene nanosheets and chemiluminescent donors. In contrast to fluorescence resonance energy transfer, CRET occurs via nonradiative dipole-dipole transfer of energy from a chemiluminescent donor to a suitable acceptor molecule without an external excitation source. We designed a graphene-based CRET platform for homogeneous immunoassay of C-reactive protein (CRP), a key marker for human inflammation and cardiovascular diseases, using a luminol/hydrogen peroxide chemiluminescence (CL) reaction catalyzed by horseradish peroxidase. According to our results, anti-CRP antibody conjugated to graphene nanosheets enabled the capture of CRP at the concentration above 1.6 ng mL(-1). In the CRET platform, graphene played a key role as an energy acceptor, which was more efficient than graphene oxide, while luminol served as a donor to graphene, triggering the CRET phenomenon between luminol and graphene. The graphene-based CRET platform was successfully applied to the detection of CRP in human serum samples in the range observed during acute inflammatory stress.

  13. Characterization of Tensile Mechanical Behavior of MSCs/PLCL Hybrid Layered Sheet

    Directory of Open Access Journals (Sweden)

    Azizah Intan Pangesty

    2016-06-01

    Full Text Available A layered construct was developed by combining a porous polymer sheet and a cell sheet as a tissue engineered vascular patch. The primary objective of this study is to investigate the influence of mesenchymal stem cells (MSCs sheet on the tensile mechanical properties of porous poly-(l-lactide-co-ε-caprolactone (PLCL sheet. The porous PLCL sheet was fabricated by the solid-liquid phase separation method and the following freeze-drying method. The MSCs sheet, prepared by the temperature-responsive dish, was then layered on the top of the PLCL sheet and cultured for 2 weeks. During the in vitro study, cellular properties such as cell infiltration, spreading and proliferation were evaluated. Tensile test of the layered construct was performed periodically to characterize the tensile mechanical behavior. The tensile properties were then correlated with the cellular properties to understand the effect of MSCs sheet on the variation of the mechanical behavior during the in vitro study. It was found that MSCs from the cell sheet were able to migrate into the PLCL sheet and actively proliferated into the porous structure then formed a new layer of MSCs on the opposite surface of the PLCL sheet. Mechanical evaluation revealed that the PLCL sheet with MSCs showed enhancement of tensile strength and strain energy density at the first week of culture which is characterized as the effect of MSCs proliferation and its infiltration into the porous structure of the PLCL sheet. New technique was presented to develop tissue engineered patch by combining MSCs sheet and porous PLCL sheet, and it is expected that the layered patch may prolong biomechanical stability when implanted in vivo.

  14. Fe3O4 and metal-organic framework MIL-101(Fe) composites catalyze luminol chemiluminescence for sensitively sensing hydrogen peroxide and glucose.

    Science.gov (United States)

    Qian Tang, Xue; Dan Zhang, Yi; Wei Jiang, Zhong; Mei Wang, Dong; Zhi Huang, Cheng; Fang Li, Yuan

    2018-03-01

    In this work, Fe 3 O 4 and metal-organic framework MIL-101(Fe) composites (Fe 3 O 4 /MIL-101(Fe)) was demonstrated to possess excellent catalytic property to directly catalyze luminol chemiluminescence without extra oxidants. We utilized Fe 3 O 4 /MIL-101(Fe) to develop a ultra-sensitive quantitative analytical method for H 2 O 2 and glucose. The possible mechanism of the chemiluminescence reaction had been investigated. Under optimal conditions, the relative chemiluminescence intensity was linearly proportional to the logarithm of H 2 O 2 concentration in the range of 5-150nM with a limit of detection of 3.7nM (signal-to-noise ratio = 3), and glucose could be linearly detected in the range from 5 to 100nM and the detection limit was 4.9nM (signal-to-noise ratio = 3). Furthermore, the present approach was successfully applied to quantitative determination of H 2 O 2 in medical disinfectant and glucose in human serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Optical fiber chemiluminescence sensor for iron (II) ion based on immobilized luminol

    International Nuclear Information System (INIS)

    Alipao, Arthur A.; Sevilla, Fortunato III.

    1999-01-01

    A chemiluminescence (CL) sensor for iron (II) was developed based on the catalytic action of the analyte on the CL reaction between luminol and oxygen. The reagents were immobilized on a cellulose membrane and set on a reaction cell which was coupled by means of an optical fiber to a spectrofluorometer. The concentration of iron(II) was quantified by measuring the intensity of the light generated from the CL reaction. The response of the sensor system was rapid and highly reproducible. Good sensitivity was displayed by the sensor system over the five orders of magnitude of iron(II) ion concentration. The calibration curve consisted of two portions: (1) a linear range at lower concentrations (7.5 x 10 -7 M to 1.0 x 10 -4 M) exhibiting a positive slope arising from a catalytic action, and (2) a linear range at higher concentrations (5.0 x 10 -2 M to 2.5 x 10 -4 M) wherein the slope is negative due to an inhibitory action of iron(II) on the CL reaction. The sensor system was highly selective for iron(II) ions. (Author)

  16. Effect of Human and Bovine Serum Albumin on kinetic Chemiluminescence of Mn (III-Tetrakis (4-Sulfonatophenyl Porphyrin-Luminol-Hydrogen Peroxide System

    Directory of Open Access Journals (Sweden)

    Sayed Yahya Kazemi

    2012-01-01

    Full Text Available The present work deals with an attempt to study the effect of human and bovine serum albumin on kinetic parameters of chemiluminescence of luminol-hydrogen peroxide system catalyzed by manganese tetrasulfonatophenyl porphyrin (MnTSPP. The investigated parameters involved pseudo-first-order rise and fall rate constant for the chemiluminescence burst, maximum level intensity, time to reach maximum intensity, total light yield, and values of the intensity at maximum CL which were evaluated by nonlinear least square program KINFIT. Because of interaction of metalloporphyrin with proteins, the CL parameters are drastically affected. The systems resulted in Stern-Volmer plots with values of 3.17×105 and 3.7×105M−1 in the quencher concentration range of 1.5×10−6 to 1.5×10−5 M for human serum albumin (HSA and bovine serum albumin (BSA, respectively.

  17. Development of mechanically expanded gelatin-AAc-PLLA/PLCL nanofibers for vascular tissue engineering by radiation-based techniques

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jin Oh; Jeong, Sung In; Seo, Da Eun; Park, Jong Seok; Gwon, Hui Jeong; Ahn, Sung Jun; Lim, Youn Mook [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Shin, Young Min [Dept. of Bioengineering, Division of Applied Chemical and Bio Engineering, Hanyang University, Seoul (Korea, Republic of)

    2015-12-15

    Vascular tissue engineering has been accessed to mimic the natural composition of the blood vessel containing inmate, media, and adventitia layers. We fabricated mechanically expanded PLLA/PLCL nanofibers using electrospinning and UTM. The pore size of the meshes was increased the gelatin immobilized AAc-PLLA/PLCL nanofibers (203.30±49.62 microns) than PLLA/PLCL nanofibers (59.99±8.66 microns) after mechanical expansion. To increase the cell adhesion and proliferation, we introduced carboxyl group, and gelatin was conjugated on them. The properties of the PLLA/PLCL nanofibers were analyzed with SEM, ATR-FTIR, TBO staining, and water contact angle measurement, general cell responses on the PLLA/PLCL nanofibers such as adhesion, proliferation, and infiltration were also investigated using smooth muscle cell (SMC). During the SMC culture, the initial viability of the cells was significantly increased on the gelatin immobilized AAc-PLLA/PLCL nanofibers, and infiltration of the cells was also enhanced on them. Therefore, gelatin immobilized AAc-PLLA/PLCL nanofibers and mechanically expanded meshes may be a good tool for vascular tissue engineering application.

  18. Poly(luminol) based sensor array for determination of dissolved chlorine in water

    Czech Academy of Sciences Publication Activity Database

    Szili, M.; Kašík, Ivan; Matějec, Vlastimil; Nagy, G.; Kovács, B.

    -, č. 192 (2014), s. 92-98 ISSN 0925-4005 Institutional support: RVO:67985882 Keywords : Chemiluminescence * Electropolymerization * Luminol Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 4.097, year: 2014

  19. Highly sensitive trivalent copper chelate–luminol chemiluminescence system for capillary electrophoresis chiral separation and determination of ofloxacin enantiomers in urine samples

    Directory of Open Access Journals (Sweden)

    Hao-Yue Xie

    2014-12-01

    Full Text Available A simple, fast and sensitive capillary electrophoresis (CE strategy combined with chemiluminescence (CL detection for analysis of ofloxacin (OF enantiomers was established in the present work. Sulfonated β-cyclodextrin (β-CD was used as the chiral additive being added into the running buffer of luminol–diperiodatocuprate (III (K5[Cu(HIO62], DPC chemiluminescence system. Under the optimum conditions, the proposed method was successfully applied to separation and analysis of OF enantiomers with the detection limits (S/N=3 of 8.0 nM and 7.0 nM for levofloxacin and dextrofloxacin, respectively. The linear ranges were both 0.010–100 μM. The method was utilized for analyzing OF in urine; the results obtained were satisfactory and recoveries were 89.5–110.8%, which demonstrated the reliability of this method. This approach can also be further extended to analyze different commercial OF medicines. Keywords: Ofloxacin, Chiral analysis, Sulfonated-β-CD, Capillary electrophoresis, Chemiluminescence

  20. Observation of chemiluminescence induced by hydrodynamic cavitation in microchannels.

    Science.gov (United States)

    Podbevsek, D; Colombet, D; Ledoux, G; Ayela, F

    2018-05-01

    We have performed hydrodynamic cavitation experiments with an aqueous luminol solution as the working fluid. Light emission, together with the high frequency noise which characterizes cavitation, was emitted by the two-phase flow, whereas no light emission from luminol was recorded in the single phase liquid flow. Light emission occurs downstream transparent microdiaphragms. The maximum level of the recorded signal was around 180 photons per second with flow rates of 380 µl/s, that corresponds to a real order of magnitude of the chemiluminescence of 75,000 photons per second. The yield of emitted photons increases linearly with the pressure drop, which is proportional to the square of the total flow rate. Chemiluminescence of luminol is a direct and a quantitative demonstration of the presence of OH hydroxyl radicals created by hydrodynamic cavitation. The presented method could be a key to optimize channel geometry for processes where radical production is essential. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Luminol, horseradish peroxidase, and glucose oxidase ternary functionalized graphene oxide for ultrasensitive glucose sensing.

    Science.gov (United States)

    Li, Fang; Ma, Wenjing; Liu, Jiachang; Wu, Xiang; Wang, Yan; He, Jianbo

    2018-01-01

    Luminol, horseradish peroxidase (HRP), and glucose oxidase (GOx) ternary functionalized graphene oxide (HRP/GOx-luminol-GO) with excellent chemiluminescence (CL) activity and specific enzymatic property was prepared via a simple and general strategy for the first time. In this approach, luminol functionalized GO (luminol-GO) was prepared by gently stirring GO with luminol. Then HRP and GOx were further co-immobilized onto the surface of luminol-GO by storing HRP and GOx with luminol-GO at 4 °C overnight, to form HRP/GOx-luminol-GO bionanocomposites. The synthesized HRP/GOx-luminol-GO could react with H 2 O 2 generated from GOx catalyzed glucose oxidization reaction, to produce strong CL emission in the presence of co-immobilized HRP. Thus, we developed an ultrasensitive, homogeneous, reagentless, selective, and simple CL sensing system for glucose detection. The resulting biosensors exhibited ultra-wide linear range from 5.0 nM to 5.0 mM, and an ultra-low detection limit of 1.2 nM, which was more than 3 orders of magnitude lower than previously reported methods. Furthermore, the sensing system was successfully applied for the detection of glucose in human blood samples.

  2. A chemiluminescent method for determination of lipid peroxidation

    International Nuclear Information System (INIS)

    Liang Xiaofeng; Hu Tianxi; Fan Xiaobing

    2003-01-01

    We established a chemiluminescent system for determination of lipid peroxidation and screening anti-oxidants. The lipid containing unsaturated fatly acids was injected into a galls tube. Luminol solution and the deionized water were added into it too. The glass tube was put into a preincubation box to incubate it for 0.5 h at 37 degree C. AAPH solution was injected into the tube for immediate measurement in a biochemiluminometer at 38-39 degree C. The pulses /6s(CP6s) were determined with T-2 program. Chemiluminescent dynamic and lipid peroxidation changes were observed continuously. Once the CL intensity of lipid peroxidation got peak, the antioxidant which has different concentration was added immediately in situ. A certain CL intensity (CP6s) was chosen as evaluation index to compare the activity of antioxidants. A luminol chemiluminescent system for determination of lipid peroxidation has been made. It was found that Vit. C, teapolyphenol, and glutathione have effects on scavenging lipid free radicals. The new method is quick, sensitive, and simple for determination of lipid peroxidation and screening antioxidants

  3. Quantitative Monitoring of Cefradine in Human Urine Using a Luminol/Sulfobutylether-β-Cyclodextrin Chemiluminescence System

    Science.gov (United States)

    Shen, M. X.; Tan, X. J.; Song, Zh. H.

    2018-05-01

    In this paper, a sensitive, rapid, and simple flow-injection chemiluminescence (FI-CL) technique is described for determining cefradine in human urine and capsule samples at the picogram level. The results show that cefradine within 0.1-100.0 nmol/L quantitatively quenches the CL intensity of the luminol/sulfo butylether-β-cyclodextrin (SBE-β-CD) system, with a relative correlation coefficient r of 0.9931. Subsequently, the possible mechanism for the quenching phenomenon is discussed in detail using the FI-CL and molecular docking methods. The proposed CL method, with a detection limit of 0.03 nmol/L (3σ) and relative standard deviations administration, the cefradine reaches a maximum value of 1.37 ± 0.02 mg/mL at 2.0 h in urine, and the total excretion is 4.41 ± 0.03 mg/mL within 8.0 h. The absorption rate constant ka, the elimination rate constant ke, and the half-life t1/2 are 0.670 ± 0.008 h-1, 0.744 ± 0.005 h-1, and 0.93 ± 0.05 h, respectively.

  4. Simultaneous determination of isoniazid and p-aminosalicylic acid by capillary electrophoresis using chemiluminescence detection.

    Science.gov (United States)

    Zhang, Xinfeng; Xuan, Yuelan; Sun, Aimin; Lv, Yi; Hou, Xiandeng

    2009-01-01

    It was found that isoniazid (ISO) or p-aminosalicylic acid (PAS) could enhance the chemiluminescence (CL) emission from Cu (II)-luminol-hydrogen peroxide system, and the increased chemiluminescence signals were proportional to their concentrations, respectively. Based on this phenomenon, a chemiluminescence method coupled to capillary electrophoresis (CE) was established for simultaneous determination of ISO and PAS. The CE conditions including running buffer and running voltage were investigated in detail. The effects of the pH of H(2)O(2) solution and the concentrations of luminol, H(2)O(2) and Cu (II) on the CL signal were also investigated carefully. Under the optimized conditions, the analysis could be accomplished within 10 min, with the limits of detection of 0.3 microg mL(-1) for ISO and 1.1 microg mL(-1) for PAS, corresponding to 7.2 and 26.4 pg per injection (24 nL), respectively. Finally, the method was validated by determining the two analytes in pharmaceutical preparation and spiked human serum samples. The results of pharmaceutical tablet analysis were in good agreement with the labeled amounts. The recoveries for ISO and PAS in human serum were in the range of 92-104% and 90-113%, respectively. Copyright 2008 John Wiley & Sons, Ltd.

  5. Enhanced luminol electrochemiluminescence triggered by an electrode functionalized with dendrimers modified with titanate nanotubes

    International Nuclear Information System (INIS)

    Lin, Yanyu; Yang, Yusheng; Dai, Hong; Xu, Guifang; Yang, Ting; Tong, Yuejin; Yang, Caiping; Chen, Guonan

    2013-01-01

    We have constructed a novel electro chemiluminescence (ECL) platform by functionalizing a poly(amidoamine) dendrimer (PAAD) with titanate nanotubes (TiNTs). The PAAD has an open spherical structure that possesses a high density of active groups and thus favors mass transport, while the TiNTs possess excellent electronic conductivity and thus can promote electron transfer on the surface of a glassy carbon electrode (GCE). A study on the intensity and stability of the ECL of luminol on the modified GCE revealed a substantial improvement compared to that of a bare GCE. The effects of the concentration of TiNTs, the pH value of the solution, and of electrochemical parameters on the intensity of the ECL of luminol were studied and resulted in a sensitive ECL sensor for hydrogen peroxide (H 2 O 2 ) that works in the concentration range of 1 nM to 0.9 μM. The scavenging effect of superoxide dismutase (SOD) on the H 2 O 2 electrode ECL was then exploited to design a biosensor for the determination of SOD in concentrations between 50 and 500 nM. (author)

  6. Detection of gamma irradiated pepper and papain by chemiluminescence

    International Nuclear Information System (INIS)

    Sattar, Abdus; Delincee, H.; Diehl, J.F.

    1987-01-01

    Chemiluminescence (CL) measurements of black pepper and of papain using luminol and lucigenin reactions were studied. Effects of grinding, irradiation (5-20 kGy) and particle size (750-140 μm) on CL of pepper, and of irradiation (10-30 kGy) on CL of papain, were investigated. All the tested treatments affected the luminescence response in both the luminol and lucigenin reactions; however, the pattern of changes in each case, was inconsistent. Optimum pepper size for maximum luminescence was 560 μm, and optimum irradiation doses were > 15 kGy for pepper and > 20 kGy for papain. Chemiluminescence may possibly be used as an indicator or irradiation treatment for pepper and papain at a dose of 10 kGy or higher, but further research is needed to establish the reliability of this method. (author)

  7. Quantitative Monitoring of Cefradine in Human Urine Using a Luminol/Sulfobutylether-β-Cyclodextrin Chemiluminescence System

    Science.gov (United States)

    Shen, M. X.; Tan, X. J.; Song, Zh. H.

    2018-05-01

    In this paper, a sensitive, rapid, and simple flow-injection chemiluminescence (FI-CL) technique is described for determining cefradine in human urine and capsule samples at the picogram level. The results show that cefradine within 0.1-100.0 nmol/L quantitatively quenches the CL intensity of the luminol/sulfo butylether-β-cyclodextrin (SBE-β-CD) system, with a relative correlation coefficient r of 0.9931. Subsequently, the possible mechanism for the quenching phenomenon is discussed in detail using the FI-CL and molecular docking methods. The proposed CL method, with a detection limit of 0.03 nmol/L (3σ) and relative standard deviations 3.0% (N = 7), is then implemented to monitor the excretion of cefradine in human urine. After orally administration, the cefradine reaches a maximum value of 1.37 ± 0.02 mg/mL at 2.0 h in urine, and the total excretion is 4.41 ± 0.03 mg/mL within 8.0 h. The absorption rate constant ka, the elimination rate constant ke, and the half-life t1/2 are 0.670 ± 0.008 h-1, 0.744 ± 0.005 h-1, and 0.93 ± 0.05 h, respectively.

  8. Enhanced Silver Nanoparticle Chemiluminescence Method for the Determination of Gemifloxacin Mesylate using Sequential Injection Analysis

    International Nuclear Information System (INIS)

    Alarfaj, N.A.; Aly, F.A.; Tamimi, A.A.

    2013-01-01

    A sequential injection analysis (SIA) with chemiluminescence detection has been proposed for the determination of the antibiotic gemifloxacin mesylate (GFX). The developed method is based on the enhancement effect of silver nanoparticles (Ag NPs) on the chemiluminescence (CL) signal of luminol-potassium ferricyanide reaction in alkaline medium. The introduction of gemifloxacin in this system produced a significant decrease in the CL intensity in presence of (Ag NPs). The optimum conditions for CL emission were investigated. Linear relationship between the decrease in CL intensity and concentration was obtained in the range 0.01-1000 ng mL-1, (r = 0.9997) with detection limit of 2.0 pg mL-1 and quantification limit of 0.01 pg mL-1. The relative standard deviation was 1.3 %. The proposed method was employed for the determination of gemifloxacin in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated, and no interference was found from these excipients. The obtained SIA results were statistically compared with those obtained from a reported method and did not show any significant difference at confidence level 95%. (author)

  9. Application of multi-step excitation schemes for detection of actinides and lanthanides in solutions by luminescence/chemiluminescence laser spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Izosimov, I. [Joint Institute for Nuclear Research, Joliot Curie 6, Dubna 141980 (Russian Federation)

    2016-07-01

    The use of laser radiation with tunable wavelength allows the selective excitation of actinide/lanthanide species with subsequent registration of luminescence/chemiluminescence for their detection. This work is devoted to applications of the time-resolved laser-induced luminescence spectroscopy and time-resolved laser-induced chemiluminescence spectroscopy for the detection of lanthanides and actinides. Results of the experiments on U, Eu, and Sm detection by TRLIF (Time Resolved Laser Induced Fluorescence) method in blood plasma and urine are presented. Data on luminol chemiluminescence in solutions containing Sm(III), U(IV), and Pu(IV) are analyzed. It is shown that appropriate selectivity of lanthanide/actinide detection can be reached when chemiluminescence is initiated by transitions within 4f- or 5f-electron shell of lanthanide/actinide ions corresponding to the visible spectral range. In this case chemiluminescence of chemiluminogen (luminol) arises when the ion of f element is excited by multi-quantum absorption of visible light. The multi-photon scheme of chemiluminescence excitation makes chemiluminescence not only a highly sensitive but also a highly selective tool for the detection of lanthanide/actinide species in solutions. (author)

  10. Zinc oxide nanoparticle-enhanced ultrasensitive chemiluminescence immunoassay for the carcinoma embryonic antigen

    International Nuclear Information System (INIS)

    Pal, Souvik; Bhand, Sunil

    2015-01-01

    An ultrasensitive enzyme-linked immunosorbent assay (ELISA) is reported for the determination of carcinoma embryonic antigen (CEA) in human serum. It was realized using a microplate reader using a 384-well plate. Monoclonal antibody (Ab) against CEA (1° Ab) acting as the capture probe was immobilized on zinc oxide nanoparticles (ZnO-NPs) in the form of self-assembled monolayers (SAMs). CEA captured by 1° Ab was quantified using a sandwich ELISA wherein a polyclonal second antibody against CEA (2° Ab) was used for detection and quantified using an HRP-labeled secondary antibody (3° Ab). The ZnO-NPs-CEA capture probe was deposited on the bottom of the wells in order to enhance capture of CEA. A 3-fold enhancement in the chemiluminescence (CL) signal of luminol is found (compared to a conventional ELISA). CEA can be quantified by this method in concentrations as low as 1 pg · mL −1 . The upper limit of detection is 20 ng · mL −1 . The use of ZnO-NPs also imparts improved thermal stability. When stored at 4 °C in phosphate-buffered saline of pH 7.4, the probe displays stability of up to 30 days. (author)

  11. Determination of hydrogen peroxide in water by chemiluminescence detection, (1). Flow injection type hydrogen peroxide detection system

    International Nuclear Information System (INIS)

    Yamashiro, Naoya; Uchida, Shunsuke; Satoh, Yoshiyuki; Morishima, Yusuke; Yokoyama, Hiroaki; Satoh, Tomonori; Sugama, Junichi; Yamada, Rie

    2004-01-01

    A flow injection type hydrogen peroxide detection system with a sub-ppb detection limit has been developed to determine hydrogen peroxide concentration in water sampled from a high temperature, high pressure hydrogen peroxide water loop. The hydrogen peroxide detector is based on luminol chemiluminescence spectroscopy. A small amount of sample water (20 μl) is mixed with a reagent mixture, an aqueous solution of luminol and Co 2+ catalyst, in a mixing cell which is installed just upstream from the detection cell. The optimum values for pH and the concentrations of luminol and Co 2+ ion have been determined to ensure a lower detectable limit and a higher reproducibility. The photocurrent detected by the detection system is expressed by a linear function of the hydrogen peroxide concentration in the region of lower concentration ([H 2 O 2 ] 2 O 2 ] in the region of higher concentration ([H 2 O 2 ] > 10 ppb). The luminous intensity of luminol chemiluminescence is the highest when pH of the reagent mixture is 11.0. Optimization of the major parameters gives the lowest detectable limit of 0.3 ppb. (author)

  12. A quantitative method for determining a representative detection limit of the forensic luminol test for latent bloodstains.

    Science.gov (United States)

    Cassidy, Brianna M; Lu, Zhenyu; Martin, Jennifer P; Tazik, Shawna K; Kellogg, Katie W; DeJong, Stephanie A; Belliveau, Elle O; Kilgore, Katherine E; Ervin, Samantha M; Meece-Rayle, Mackenzie; Abraham, Alyssa M; Myrick, Michael L; Morgan, Stephen L

    2017-09-01

    The luminol test has been used for over 60 years by forensic investigators for presumptive identification of blood and visualization of blood splatter patterns. Multiple studies have estimated the limit of detection (LD) for bloodstains when luminol is employed, with results ranging from 100× to 5,000,000× dilute. However, these studies typically have not identified and controlled important experimental variables which may affect the luminol LD for bloodstains. Without control of experimental parameters in the laboratory, variables which affect the potential of presumptive bloodstain test methods remain largely unknown, and comparisons required to establish new, more powerful detection methods are simply impossible. We have developed a quantitative method to determine the relationship between the amount of blood present and its reaction with luminol by measuring, under controlled conditions, the resulting chemiluminescent intensity with a video camera, combined with processing of the digital intensity data. The method resulted in an estimated LD for bloodstains on cotton fabric at ∼200,000× diluted blood with a specific luminol formulation. Although luminol is the focus of this study, the experimental protocol used could be modified to study effects of variables using other blood detection reagents. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Chemiluminescence measurements as an identification method for gamma-irradiated foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Boegl, W; Heide, L

    1985-01-01

    Samples of 19 different spices, milk powder, whole onions and frozen chicken were exposed to a Co-60 source with radiation doses up to 10/sup 4/ Gy. The subsequent reaction of the irradiated foodstuffs in a luminol solution resulted in light emission (chemiluminescence). This effect can be used as an indicator of radiation treatment.

  14. Chemiluminescence immunoassay for prostate-specific antigen

    International Nuclear Information System (INIS)

    Zhang Xuefeng; Liu Yibing; Jia Juanjuan; Xu Wenge; Li Ziying; Chen Yongli; Han Shiquan

    2008-01-01

    The chemiluminescence immunoassay (CLIA) for serum total prostate-specific antigen (T-PSA) was developed. The reaction of luminol with hydrogen peroxide was introduced into this chemiluminescence system. The detection limit is established as 0.12 μg/L (n=10, mean of zero standard + 2SD) and the analytical recovery of PSA is 83.8%-118.7%. The intra-assay and inter-assay CVs vary from 4.4%-5.0% and 6.2%-11.7%, respectively. The experimental correlation coefficient of dilution is found to be 0.999. Compared with immunoradiometric assay (IRMA) kits, the correlative equation is y=1.07x+0.68, and correlation coefficient r=0.97. The standard range for the method is 1.5-80 μg/L, and it presents good linearity. (authors)

  15. Biocompatibility Assessment of PLCL-Sericin Copolymer Membranes Using Wharton’s Jelly Mesenchymal Stem Cells

    Directory of Open Access Journals (Sweden)

    Kewalin Inthanon

    2016-01-01

    Full Text Available Stem cells based tissue engineering requires biocompatible materials, which allow the cells to adhere, expand, and differentiate in a large scale. An ideal biomaterial for clinical application should be free from mammalian products which cause immune reactivities and pathogen infections. We invented a novel biodegradable poly(L-lactic-co-ε-caprolactone-sericin (PLCL-SC copolymer membrane which was fabricated by electrospinning. Membranes with concentrations of 2.5 or 5% (w/v SC exhibited qualified texture characteristics with a noncytotoxic release profile. The hydrophilic properties of the membranes were 35–40% higher than those of a standard PLCL and commercial polystyrene (PS. The improved characteristics of the membranes were due to an addition of new functional amide groups, C=O, N–H, and C–N, onto their surfaces. Degradation of the membranes was controllable, depending on the content proportion of SC. Results of thermogram indicated the superior stability and crystallinity of the membranes. These membranes enhanced human Wharton’s jelly mesenchymal stem cells (hWJMSC proliferation by increasing cyclin A and also promoted cell adhesion by upregulating focal adhesion kinase (FAK. On the membranes, hWJMSC differentiated into a neuronal lineage with the occurrence of nestin. These data suggest that PLCL-SC electrospun membrane represents some properties which will be useful for tissue engineering and medical applications.

  16. Free radical scavenging activity of coenzyme Q measured by a chemiluminescent assay

    International Nuclear Information System (INIS)

    Battino, Maurizio; Ferri, Elida; Girotti, Stefano; Lenaz, Giorgio

    1991-01-01

    Involvement of coenzyme Q (CoQ) in anti-oxydant activities, in addition to its major redox role, has frequently been suggested in recent years. In order to elucidate if CoQ could really be engaged in scavenging free radicals produced endogenously in a biological system, an experimental system was developed in which beef heart mitochondria in the presence of a saturating NADH concentration and of rotenone produce free radicals. The presence of oxygen-reactive forms was easily detected by a luminol-dependent chemiluminescence process. The chemi-luminescence assay showed that short-chain CoQ homologues can act as pro-oxidants, enhancing free radical effects, while exogenous coenzyme Q 10 could scavenge free radicals, especially at very low concentration. In this system, exogenous CoQ 10 was more effective than α-tocopherol at the same concentration in scavenging free radicals. The molecular mechanism that leads to this activity is still unclear, but these results are of biochemical importance because they indicate that CoQ may act as an anti=oxidant in situations mimicking physiopathological conditions. This direct chemiluminescent method is promising for studies of biochemical processes which involve active oxygen species. (author). 24 refs.; 4 figs

  17. Evaluation of Antibacterial Enrofloxacin in Eggs by Matrix Solid Phase Dispersion-Flow Injection Chemiluminescence

    Directory of Open Access Journals (Sweden)

    Xiaocui Duan

    2014-01-01

    Full Text Available The study based on the chemiluminescence (CL reaction of potassium ferricyanide and luminol in sodium hydroxide medium, enrofloxacin (ENRO could dramatically enhance CL intensities and incorporated with matrix solid-phase dispersion (MSPD technique (Florisil used as dispersant, dichloromethane eluted the target compounds. A simple flow injection chemiluminescence (FL-CL method with MSPD technique for determination of ENRO in eggs was described. Under optimal conditions, the CL intensities were linearly related to ENRO concentration ranging from 4.0×10-8 g.L−1 to 5.0×10-5 g.L−1, with a correlation coefficient of 0.9989 and detection limit of 5.0×10-9 g.L−1. The relative standard deviation was 3.6% at an ENRO concentration of 2.0×10-6 g.L−1. Our testing technique can help ensure food safety, and thus, protect public health.

  18. An automatic enzyme immunoassay based on a chemiluminescent lateral flow immunosensor.

    Science.gov (United States)

    Joung, Hyou-Arm; Oh, Young Kyoung; Kim, Min-Gon

    2014-03-15

    Microfluidic integrated enzyme immunosorbent assay (EIA) sensors are efficient systems for point-of-care testing (POCT). However, such systems are not only relatively expensive but also require a complicated manufacturing process. Therefore, additional fluidic control systems are required for the implementation of EIAs in a lateral flow immunosensor (LFI) strip sensor. In this study, we describe a novel LFI for EIA, the use of which does not require additional steps such as mechanical fluidic control, washing, or injecting. The key concept relies on a delayed-release effect of chemiluminescence substrates (luminol enhancer and hydrogen peroxide generator) by an asymmetric polysulfone membrane (ASPM). When the ASPM was placed between the nitrocellulose (NC) membrane and the substrate pad, substrates encapsulated in the substrate pad were released after 5.3 ± 0.3 min. Using this delayed-release effect, we designed and implemented the chemiluminescent LFI-based automatic EIA system, which sequentially performed the immunoreaction, pH change, substrate release, hydrogen peroxide generation, and chemiluminescent reaction with only 1 sample injection. In a model study, implementation of the sensor was validated by measuring the high sensitivity C-reactive protein (hs-CRP) level in human serum. © 2013 Elsevier B.V. All rights reserved.

  19. Fiber-Optic Chemiluminescent Biosensors for Monitoring Aqueous Alcohols and Other Water Quality Parameters

    Science.gov (United States)

    Verostko, Charles E. (Inventor); Atwater, James E. (Inventor); Akse, James R. (Inventor); DeHart, Jeffrey L. (Inventor); Wheeler, Richard R. (Inventor)

    1998-01-01

    A "reagentless" chemiluminescent biosensor and method for the determination of hydrogen peroxide, ethanol and D-glucose in water is disclosed. An aqueous stream is basified by passing it through a solid phase base bed. Luminol is then dissolved in the basified effluent at a controlled rate. Oxidation of the luminol is catalyzed by the target chemical to produce emitted light. The intensity of the emitted light is detected as a measure of the target chemical concentration in the aqueous stream. The emitted light can be transmitted by a fiber optic bundle to a remote location from the aqueous stream for a remote reading of the target chemical concentration.

  20. Investigation of iron(III) reduction and trace metal interferences in the determination of dissolved iron in seawater using flow injection with luminol chemiluminescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Ussher, Simon J. [School of Earth, Ocean and Environmental Sciences (SEOES), University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom); Milne, Angela [School of Earth, Ocean and Environmental Sciences (SEOES), University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom); Department of Oceanography, Florida State University, Tallahassee, FL 32306-4320 (United States); Landing, William M. [Department of Oceanography, Florida State University, Tallahassee, FL 32306-4320 (United States); Attiq-ur-Rehman, Kakar [Department of Chemistry, University of Balochistan, Quetta (Pakistan); Seguret, Marie J.M.; Holland, Toby [School of Earth, Ocean and Environmental Sciences (SEOES), University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom); Achterberg, Eric P. [National Oceanography Centre, University of Southampton, European Way, Southampton SO14 3ZH (United Kingdom); Nabi, Abdul [Department of Chemistry, University of Balochistan, Quetta (Pakistan); Worsfold, Paul J., E-mail: pworsfold@plymouth.ac.uk [School of Earth, Ocean and Environmental Sciences (SEOES), University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2009-10-12

    A detailed investigation into the performance of two flow injection-chemiluminescence (FI-CL) manifolds (with and without a preconcentration column) for the determination of sub-nanomolar dissolved iron (Fe(II) + Fe(III)), following the reduction of Fe(III) by sulphite, in seawater is described. Kinetic experiments were conducted to examine the efficiency of reduction of inorganic Fe(III) with sulphite under different conditions and a rigorous study of the potential interference caused by other transition metals present in seawater was conducted. Using 100 {mu}M concentrations of sulphite a reduction time of 4 h was sufficient to quantitatively reduce Fe(III) in seawater. Under optimal conditions, cobalt(II) and vanadium(IV)/(III) were the major positive interferences and strategies for their removal are reported. Specifically, cobalt(II) was masked by the addition of dimethylglyoxime to the luminol solution and vanadium(IV) was removed by passing the sample through an 8-hydroxyquinoline column in a low pH carrier stream. Manganese(II) also interfered by suppression of the CL response but this was not significant at typical open ocean concentrations.

  1. Quantitation of immunoadsorbed flavoprotein oxidases by luminol-mediated chemiluminescence.

    Science.gov (United States)

    Hinkkanen, A; Maly, F E; Decker, K

    1983-04-01

    The detection of the flavoenzymes 6-hydroxy-L-nicotine oxidase and 6-hydroxy-D-nicotine oxidase at the sub-femtomol level was achieved by coupling the reaction of the immunoadsorbed proteins to the peroxidase-catalysed oxidation of luminol. The H2O2-producing oxidases retained their full activity when bound to the respective immobilized antibodies. This fact allowed the concentration of the enzymes from very dilute solutions and the quantitative assay of their activities in the microU range. Due to strict stereoselectivity and the absence of immunological cross-reactivity, the two flavoproteins could be determined in the same solution. This method was used to measure the 6-hydroxy-D-nicotine oxidase and 6-hydroxy-L-nicotine oxidase activities in Escherichia coli RR1 and different Arthrobacter strains cultured under non-inducing conditions. The same activity ratio of 6-hydroxy-L-nicotine oxidase/6-hydroxy-D-nicotine oxidase as in D L-nicotine-induced cells of A. oxidans was observed in non-induced wild type and in riboflavin-requiring (rf-) mutant cells of this aerob.

  2. Strong enhancement of the electrochemiluminescence of luminol by AuAg and PtAg alloy nanoclusters, and its sensitization by phenolic artificial oestrogens

    International Nuclear Information System (INIS)

    Wang, Ke; Tu, Yifeng; Wei, Xiuhua

    2014-01-01

    This paper reports on the synthesis of AuAg and PtAg alloy nanoclusters (NCs) and their enhancement effect on the electrochemiluminescence (ECL) of luminol. The conditions of synthesis were optimized, and the structure and properties of the NCs were characterized by X-ray diffraction, transmission electron microscopy, electrochemistry, and optical spectroscopy. The NCs are found to intensify (by up to 20 times) the ECL of luminol in solution of pH 8.5. This finding can largely extend the useful pH range of the ECL of luminol. The enhanced ECL is strongly affected by oxygen and hydrogen peroxide, and the mechanism of enhancement is attributed to the accelerated production of reactive oxygen species. The enhanced ECL is also affected by phenolic artificial estrogens, and this was used for their determination with detection limits as low as 700 pg L −1 (with AuAg) and 1.6 ng L −1 (with PtAg). The method was applied to the determination of such estrogens in egg samples using diethylstilbestrol as a reference substance. (author)

  3. TGF-β3 encapsulated PLCL scaffold by a supercritical CO2-HFIP co-solvent system for cartilage tissue engineering.

    Science.gov (United States)

    Kim, Su Hee; Kim, Soo Hyun; Jung, Youngmee

    2015-05-28

    Mimicking the native tissue microenvironment is critical for effective tissue regeneration. Mechanical cues and sustained biological cues are important factors, particularly in load-bearing tissues such as articular cartilage or bone. Carriers including hydrogels and nanoparticles have been investigated to achieve sustained release of protein drugs. However, it is difficult to apply such carriers alone as scaffolds for cartilage regeneration because of their weak mechanical properties, and they must be combined with other biomaterials that have adequate mechanical strength. In this study, we developed the multifunctional scaffold which has similar mechanical properties to those of native cartilage and encapsulates TGF-β3 for chondrogenesis. In our previous work, we confirmed that poly(lactide-co-caprolacton) (PLCL) did not foam when exposed to supercritical CO2 below 45°C. Here, we used a supercritical carbon dioxide (scCO2)-1,1,1,3,3,3-hexafluoro-2-propanol (HFIP) co-solvent system to facilitate processing under mild conditions because high temperature causes protein denaturation and decreases bioactivity of the protein. This processing made it possible to fabricate a TGF-β3 encapsulated elastic porous PLCL scaffold at 37°C. We investigated the tissue regeneration efficiency of the TGF-β3 encapsulated PLCL scaffold using human adipose-derived stem cells (ADSCs) in vitro and in vivo (Groups; i. PLCL scaffold+Fibrin gel+TGF-β3, ii. TGF-β3 encapsulated PLCL scaffold+Fibrin gel, iii. TGF-β3 encapsulated PLCL scaffold). We evaluated the chondrogenic abilities of the scaffolds at 4, 8, and 12weeks after subcutaneous implantation of the constructs in immune-deficient mice. Based on TGF-β3 release studies, we confirmed that TGF-β3 molecules were released by 8weeks and remained in the PLCL matrix. Explants of TGF-β3 encapsulated scaffolds by a co-solvent system exhibited distinct improvement in the compressive E-modulus and deposition of extracellular matrix

  4. Suitability of a PLCL fibrous scaffold for soft tissue engineering applications: A combined biological and mechanical characterisation.

    Science.gov (United States)

    Laurent, Cédric P; Vaquette, Cédryck; Liu, Xing; Schmitt, Jean-François; Rahouadj, Rachid

    2018-04-01

    Poly(lactide-co-ε-caprolactone) (PLCL) has been reported to be a good candidate for tissue engineering because of its good biocompatibility. Particularly, a braided PLCL scaffold (PLL/PCL ratio = 85/15) has been recently designed and partially validated for ligament tissue engineering. In the present study, we assessed the in vivo biocompatibility of acellular and cellularised scaffolds in a rat model. We then determined its in vitro biocompatibility using stem cells issued from both bone marrow and Wharton Jelly. From a biological point of view, the scaffold was shown to be suitable for tissue engineering in all these cases. Secondly, while the initial mechanical properties of this scaffold have been previously reported to be adapted to load-bearing applications, we studied the evolution in time of the mechanical properties of PLCL fibres due to hydrolytic degradation. Results for isolated PLCL fibres were extrapolated to the fibrous scaffold using a previously developed numerical model. It was shown that no accumulation of plastic strain was to be expected for a load-bearing application such as anterior cruciate ligament tissue engineering. However, PLCL fibres exhibited a non-expected brittle behaviour after two months. This may involve a potential risk of premature failure of the scaffold, unless tissue growth compensates this change in mechanical properties. This combined study emphasises the need to characterise the properties of biomaterials in a pluridisciplinary approach, since biological and mechanical characterisations led in this case to different conclusions concerning the suitability of this scaffold for load-bearing applications.

  5. A readout circuit dedicated for the detection of chemiluminescence using a silicon photomultiplier

    Science.gov (United States)

    Baszczyk, M.; Dorosz, P.; Mik, L.; Kucewicz, W.; Reczynski, W.; Sapor, M.

    2018-05-01

    A readout circuit dedicated for the detection of the chemiluminescence phenomenon using a silicon photomultiplier (SiPM) is presented. During chemiluminescence, light is generated as a result of chemical reaction. Chemiluminescence is used in many applications within medicine, chemistry, biology and biotechnology, and is one of the most important sensing techniques in biomedical science and clinical medicine. The front-end electronics consist of a preamplifier and a fast shaper—this produces pulses, the peaking time which is 3.6 ns for a single photon and the FWHM is 3.8 ns. The system has been optimised to measure chemiluminescence—it is sensitive at the level of single photons, it generates a low number of overlapping pulses and is accurate. Two methods of signal detection are analysed and compared: the counting of events and amplitude detection. The relationship between the chemiluminescence light intensity and the concentration of the chemical compound (luminol) is linear in the range of the tested concentrations and has strong linearity parameters and low prediction intervals.

  6. Development and application of a luminol-based nitrogen dioxide detector

    International Nuclear Information System (INIS)

    Wendel, G.J.

    1985-01-01

    An instrument for the continuous measurement of nitrogen dioxide (NO 2 ) at all atmospheric concentration ranges and conditions was developed. The detector is based on the chemiluminescent reaction between 5-amino-2,3-dihydro-1,4-phthalazinedione (luminol) and NO 2 in alkaline aqueous solution. Development included the optimization of the cell design and the solution composition. Sodium sulfite (Na 2 SO 3 ) and methanol (CH 3 OH) were added to the solution to improve sensitivity and specificity. The detector was favorably compared to two different instruments measuring NO 2 by NO + O 3 chemiluminescent and by a tunable diode laser absorption spectrometry system. The detector has demonstrated a detection limit of 30 parts-per-trillion by volume (ppt) and a frequency response of 0.3 Hz. The instrument was operated for two one-month periods on Bermuda. The purpose was to study air masses from the East Coast of the United States after transport over the ocean. Average daily values were 400 ppt with values as low as 100 ppt measured. Other field experiments involved monitoring of NO 2 in ambient air in the range of 1 to 60 parts-per-billion by volume

  7. A sensitive inhibition chemiluminescence method for the determination of 6-mercaptopurine in tablet and biological fluid using the reaction of luminol-Ag(III) complex in alkaline medium

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Hanwen, E-mail: hanwen@hbu.edu.cn [College of Chemistry and Environmental Science, Hebei University, Key Laboratory of Analytical Science and Technology of Hebei Province, Baoding 071002 (China); Wang, Ting; Liu, Xuyang; Chen, Peiyun [College of Chemistry and Environmental Science, Hebei University, Key Laboratory of Analytical Science and Technology of Hebei Province, Baoding 071002 (China)

    2013-02-15

    A sensitive inhibition chemiluminescence (CL) method for the determination of 6-mercaptopurine (6-MP) is developed. The mechanism of the CL reaction between Ag(III) complex {l_brace}[Ag(HIO{sub 6}){sub 2}]{sup 5-}{r_brace} and luminol in alkaline solution was proposed, along with the inhibition mechanism of 6-MP on the CL emission. The inhibition degree of CL emission was proportional to the logarithm of 6-MP concentration. The effects of the reaction conditions on CL emission and inhibition were examined. Under the optimized conditions, the detection limit (s/n=3) was 3.7 Multiplication-Sign 10{sup -10} g ml{sup -1}. The recoveries of 6-MP were in the range of 97.7-105% with the RSD of 2.1-3.4% (n=5) for tablet samples, 103-106% with the RSDs of 1.1-2.1% for spiked serum sample, and 97.2-101% with the RSD of 2.0-4.5% for spiked urine sample. The accuracy of this method for the tablet analysis was examined by comparing with the pharmacopoeia method. The proposed method was used for the determination of 6-MP at clinically relevant concentrations in real urine and serum samples with satisfactory results. - Highlights: Black-Right-Pointing-Pointer A sensitive inhibition chemiluminescence (CL) method for the determination of 6-MP is developed. Black-Right-Pointing-Pointer The inhibition mechanism of 6-MP on the CL emission was proposed. Black-Right-Pointing-Pointer The detection limit was 3.7 Multiplication-Sign 10{sup -10} g ml{sup -1}. Black-Right-Pointing-Pointer The accuracy was examined by comparing with the pharmacopoeia method.

  8. Enhanced anodic Ru(bpy)32+ electrogenerated chemiluminescence by polyphenols

    International Nuclear Information System (INIS)

    Lei Rong; Xu Xiao; Xu Da; Zhu Gang; Li Na; Liu Huwei; Li Kean

    2008-01-01

    Anodic Ru(bpy) 3 2+ electrogenerated chemiluminescence (ECL) can be enhanced by polyphenols in alkaline solution. Spin trapping-electron spin resonance (ESR) experiments verified that reactive oxygen species (ROS) were generated during the electrolysis of Ru(bpy) 3 2+ in alkaline solution, and oxidation of quercetin enhanced Ru(bpy) 3 2+ ECL at anodic potential by producing additional ROS. This ECL enhancement can be used to analyze real sample and evaluate antioxidant activity of polyphenols

  9. Chemiluminescence immunoassay for chloramphenicol

    International Nuclear Information System (INIS)

    Lin Si; Xu Wenge; Liu Yibing

    2007-06-01

    A simple, solid-phase chemiluminescence immunoassay (CLIA) for the measurement of Chloramphenicol(CAP) in foodstuffs is described. A rabbit anti-CAP IgG is passively adsorbed onto the walls of polypropylene plates. The labeled conjugant is horseradish peroxidase(HRP) conjugate of CAP. Luminol solution is used as the substrate of HRP. The light yield is inversely proportional to the concentration of CAP. The method has a similar sensitivity (0.05 ng/mL), specificity, precision, and accuracy to a conventional enzyme immunoassay (EIA). The intra-assay and inter-assay CVs of ten samples were <8 and <20%, respectively, and the analytical recovery of the method was 87% 100%. The experimental correlation coefficient of dilution was found to be 0.999 using milk supernatant as buffer. The assay range for the method was 0.1-10 ng/mL, and it displayed good linearity. (authors)

  10. Applications of capillary electrophoresis with chemiluminescence detection in clinical, environmental and food analysis. A review

    International Nuclear Information System (INIS)

    Lara, Francisco J.; Airado-Rodríguez, Diego; Moreno-González, David; Huertas-Pérez, José F.; García-Campaña, Ana M.

    2016-01-01

    This paper reviews the latest developments and analytical applications of chemiluminescence detection coupled to capillary electrophoresis (CE-CL). Different sections considering the most common CL systems have been included, such as the tris(2,2′-bipyridine)ruthenium(II) system, the luminol and acridinium derivative reactions, the peroxyoxalate CL or direct oxidations. Improvements in instrumental designs, new strategies for improving both resolution and sensitivity, and applications in different fields such as clinical, pharmaceutical, environmental and food analysis have been included. This review covers the literature from 2010 to 2015. - Highlights: • An up-to-date critical review about the evolution of CE-CL is presented. • Tris(2,2′-bipyridine)ruthenium(II) and luminol as the most used CL systems. • Instrumental designs and strategies for improving resolution and sensitivity. • Applications in clinical, pharmaceutical, environmental and food analysis.

  11. Irradiation monitoring of spices by chemiluminescence method

    International Nuclear Information System (INIS)

    Bhatti, K.A.; Khan, H.M.; Sattar, A.; Ahmad, A.

    2001-01-01

    Some spices (cumin, coriander, black pepper and red pepper), commonly used due to their specific aroma and nutritional value were studied using chemiluminescence (CL) method to test whether the food has been irradiated or not. The spices were ground to different mesh sizes and subjected to gamma ray doses of 2.5, 5.0, 7.5 and 10 Kgy. The effect of radiation doses and particle size on the CL response of irradiated and un-irradiated samples was checked using luminol and lucigenin sensitizers. The storage experiment was also performed for all spices with both the sensitizers in order to pick the suitable sensitizer for CL study. During this study Co-60 gamma ray source and Bio-orbit 1250 luminometer were used after precise calibration

  12. Gold nanorods-enhanced rhodamine B-permanganate chemiluminescence and its analytical application.

    Science.gov (United States)

    Hassanzadeh, Javad; Amjadi, Mohammad; Manzoori, Jamshid L; Sorouraddin, Mohammad Hossein

    2013-04-15

    A novel enhanced chemiluminescence system was developed by applying gold nanorods (Au NRs) as catalysts in rhodamine B-permanganate reaction. Au NRs with three different aspect ratios were synthesized by seed mediated growth method and characterized by UV-Vis spectra and transmission electron microscopy. It was demonstrated that Au NRs have much higher catalytic effect than spherical nanoparticles on rhodamine B-permanganate chemiluminescence reaction. Among various sizes of Au NRs, those with average aspect ratio of 3.0 were found to have the most remarkable catalytic activity. As an analytical application of the new chemiluminescence system, albumin as a model protein was quantified based on its interaction with NRs. Albumin binds to Au NRs active surfaces and inhibits their catalytic action and therefore decreases the intensity of chemiluminescence. This diminution effect is linearly related to the concentration of the human and bovine serum albumin over the ranges of 0.45-90 and 0.75-123 nmol L(-1), respectively with the corresponding limits of detection of 0.18 and 0.30 nmol L(-1). The method was successfully applied to the determination of albumin in human and bovine serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Determination of phenols by flow injection and liquid chromatography with on-line quinine-sensitized photo-oxidation and quenched luminol chemiluminescence detection

    International Nuclear Information System (INIS)

    Zhang Wei; Danielson, Neil D.

    2003-01-01

    An on-line quinine-sensitized photo-oxidation with quenched chemiluminescence (CL) detection method is developed for phenols using flow injection (FI) and liquid chromatography (LC). This detection method is based on the decrease of light emission from the luminol CL reaction due to the photo-oxidation of phenols that scavenge the photogenerated reactive oxygen species (e.g. singlet oxygen ( 1 O 2 ) and superoxide (O 2 · - )). On-line photo-oxidation is achieved using a coil photo-reactor made from fluoroethylene-propylene copolymer tubing (3048 mmx0.25 mm i.d.) coiled around a mercury UV lamp. A buffer of pH 7 and a concentration of 350 μM for quinine sulfate are determined optimum for the sensitized photo-oxidation. Using a carrier system flow rate of 60 μl/min, calibration curves taken by FI for 10 phenolic compounds in aqueous solutions showed this decreasing sensitivity order: 4-chlorophenol, phenol, 4-nitrophenol, 3-hydroxy-L-kynurenine, 2-nitrophenol, salicylate, 3-nitrophenol, catechol, 2,4-dinitrophenol, and 2,4-dichlorophenol. This detection method using two tandem coil photo-reactors is also applied for the LC separation of phenol, 4-nitrophenol and 4-chlorophenol on an octadecyl (C18) silica LC column using acetonitrile-H 2 O (40:60, v/v) as a mobile phase. The quenched CL detection limits (about 1 μM or 20 pmol) for phenol and 4-chlorophenol are comparable to those for UV detection at 254 nm. Some selectivity in the quenched CL detection is evident by no interference in the FI phenol response even when benzaldehyde and phenethanol concentrations are 8 and 15 times that of phenol

  14. Chemiluminescence response of whole blood and separated blood cells in cases of experimentally induced pancreatitis and MDTQ-DA-Trasylol-ascorbic acid therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, T.; Schuster, R.; Lauschke, G.; Trausch, M. (Medical Academy of Dresden (Germany). Department of Surgery); Albrecht, S. (Medical Academy of Dresden (Germany). Institute of Clinical Chemistry); Kopprasch, S.; Kuehne, H. (Medical Academy of Dresden (Germany). Institute of Pathological Biochemistry)

    1991-12-24

    The formation of reactive O{sub 2} species in the pancreas of pigs after induction of necrotizing or oedematous pancreatitis was studied by means of luminol- and lucigenin-sensitized chemiluminescence. The effect of 2,2-dimethyl-4-methanesulphonic acid-1,2-dihydroquinoline in combination with Trasylol and ascorbic acid was studied in vivo. This combined therapy leads to a reduction in the chemiluminescence response by 50-70% with prevention of pancreatogenic shock and multiple organ failure by improvement of the gluthathione status. A combination of radical traps, kallikrein inhibitors and natural antioxidative sub-stances is an efficient alternative therapy in cases of acute pancrea-titis. (author). 10 refs.; 5 figs.

  15. Electrochemiluminescence of luminol enhanced by the synergetic catalysis of hemin and silver nanoparticles for sensitive protein detection.

    Science.gov (United States)

    Jiang, Xinya; Chai, Yaqin; Wang, Haijun; Yuan, Ruo

    2014-04-15

    A novel and ultrasensitive electrochemiluminescence (ECL) immunosensor, which was based on the amplifying ECL of luminol by hemin-reduced graphene oxide (hemin-rGO) and Ag nanoparticles (AgNPs) decorated reduced graphene oxide (Ag-rGO), was constructed for the detection of carcinoembryonic antigen (CEA). For this proposed sandwich-type ECL immunosensor, Au nanoparticles electrodeposited (DpAu) onto hemin-rGO (DpAu/hemin-rGO) constructed the base of the immunosensor. DpAu had outstanding electrical conductivity to promote the electron transfer at the electrode interface and had good biocompatibility to load large amounts of primary antibody (Ab1), which provided an excellent platform for this immunosensor. Moreover, AgNPs and glucose oxidase (GOD) functionalized graphene labeled secondary antibody (Ag-rGO-Ab2-GOD) was designed as the signal probe for the sandwiched immunosensor. Not only did the hemin-rGO improve the electron transfer of the electrode surface, but hemin also further amplified the ECL signal of luminol in the presence of hydrogen peroxide (H2O2). With the aid of Ag-rGO-Ab2-GOD, enhanced signal was obtained by in situ generation of H2O2 and catalysis of AgNPs to ECL reaction of the luminol-H2O2 system. The as-prepared ECL immunosensor exhibited excellent analytical property for the detection of CEA in the range from 0.1 pg mL(-1) to 160 ng mL(-1) with a detection limit of 0.03 pg mL(-1) (SN(-1)=3). © 2013 Published by Elsevier B.V.

  16. Sequential Injection Determination of D-Glucose by Chemiluminescence Using an Open Tubular Immobilised Enzyme Reactor

    DEFF Research Database (Denmark)

    Liu, Xuezhu; Hansen, Elo Harald

    1996-01-01

    A sequential injection analysis system is described that incorporates a nylon tubular reactor containing immobilised glucose oxidase, allowing determination of D-glucose by means of subsequent luminol chemiluminescence detection of the hydrogen peroxide generated in the enzymatic reaction....... The operating parameters were optimised by fractional factorial screening and response surface modelling. The linear range of D-glucose determination was 30-600 mu M, With a detection limit of 15 mu M using a photodiode detector. The sampling frequency was 54 h(-1). Lower LOD (0.5 mu M D-glucose) could...

  17. Eco-friendly synthesis of gelatin-capped bimetallic Au-Ag nanoparticles for chemiluminescence detection of anticancer raloxifene hydrochloride.

    Science.gov (United States)

    Alarfaj, Nawal A; El-Tohamy, Maha F

    2016-09-01

    This study described the utility of green analytical chemistry in the synthesis of gelatin-capped silver, gold and bimetallic gold-silver nanoparticles (NPs). The preparation of nanoparticles was based on the reaction of silver nitrate or chlorauric acid with a 1.0 wt% aqueous gelatin solution at 50°C. The gelatin-capped silver, gold and bimetallic NPs were characterized using transmission electron microscopy, UV-vis, X-ray diffraction and Fourier transform infrared spectroscopy, and were used to enhance a sensitive sequential injection chemiluminescence luminol-potassium ferricyanide system for determination of the anticancer drug raloxifene hydrochloride. The developed method is eco-friendly and sensitive for chemiluminescence detection of the selected drug in its bulk powder, pharmaceutical injections and biosamples. After optimizing the conditions, a linear relationship in the range of 1.0 × 10(-9) to 1.0 × 10(-1)  mol/L was obtained with a limit of detection of 5.0 × 10(-10)  mol/L and a limit of quantification of 1.0 × 10(-9)  mol/L. Statistical treatment and method validation were performed based on ICH guidelines. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Luminol/CdTe quantum dots/sodium periodate system in conjunction with response-surface methodology for chemiluminometric determination of some tetracyclines

    International Nuclear Information System (INIS)

    Imani-Nabiyyi, Amin; Sorouraddin, Mohammad H.; Amjadi, Mohammad; Naseri, Abdolhossein

    2014-01-01

    A simple and sensitive chemiluminometric method is described for the determination of tetracycline (TC) and oxytetracycline (OTC) in their hydrochloride form on the basis of drastic enhancement of the chemiluminescence (CL) from the luminol/L-cysteine-capped CdTe quantum dots (QDs)/sodium periodate system, caused by the presence of TC and OTC hydrochloride. The method uses pH value at which tetracyclines have proven to be stable. Response surface methodology was exploited for optimizing the experimental conditions. The synthesized QDs were characterized by means of X-ray diffraction (XRD), transmission electron microscopy (TEM), UV–vis spectroscopy, and photoluminescence spectroscopy. A possible mechanism of the CL system was proposed based on the CL spectra and the effect of some specific radical-scavengers on the system. Under the optimum conditions linear dynamic ranges of 5.0×10 −8 –6.0×10 −6 mol L −1 and 5.0×10 −8 –8.0×10 −6 mol L −1 were observed for TC and OTC, respectively with corresponding detection limits of 2.2×10 −8 mol L −1 and 3.0×10 −8 mol L −1 . The precision (RSD%) for five replicate determinations of TC and OTC were respectively no more than 3.4% and 4.0%. The method was satisfactorily applied to the determination of TC.HCl and OTC.HCl in water samples, pharmaceutical formulations, and honey. - Highlights: • A simple, rapid, and sensitive method for determination of some tetracyclines. • Enhancement of CL of luminol/Cys-capped CdTe QDs/NaIO 4 with TC.HCl and OTC.HCl. • No need to chemical, photochemical, or any peculiar pretreatment of the samples. • Measuring the analytes in conditions at which they are stable. • Capable of measuring TCs in pharmaceutical, water, and honey samples

  19. Phagocytic and chemiluminescent responses of mouse peritoneal macrophages to living and killed Salmonella typhimurium and other bacteria

    International Nuclear Information System (INIS)

    Tomita, T.; Blumenstock, E.; Kanegasaki, S.

    1981-01-01

    In the presence of luminol, resident as well as thioglycolate-induced and immunized macrophages emitted chemiluminescence more efficiently when the cells were exposed to living Salmonella typhimurium than when they were exposed to the same bacterium killed by ultraviolet light or heat. This phenomenon was observed whether or not the bacterium was opsonized. The different response to living and killed bacteria was also found with Escherichia coli, Pseudomonas aeruginosa, Proteus morganii, and Enterobacter aerogenes, but not with Shigella sonnei, Klebsiella pneumoniae, and Propionibacterium acnes. The results suggest that macrophages respond better to living, motile bacteria than to nonmotile or killed bacteria. The experimental results obtained with motility mutants of S. typhimurium, E. coli, and P. aeruginosa confirm that macrophages exposed to the motile bacteria emit chemiluminescence more efficiently and ingest the motile bacteria at a much faster rate than the nonmotile bacteria

  20. Determination of sibutramine with a new sensor based on luminol electrochemiluminescence

    International Nuclear Information System (INIS)

    Wang Shaowei; Yu Jinghua; Wan Fuwei; Ge Shenguang; Yan Mei; Zhang Meng

    2011-01-01

    A flow injection electrochemiluminescence (FI-ECL) analysis method for the determination of sibutramine in the presence of luminol was studied under conventional cyclic voltammetry in alkaline Na 2 CO 3 -NaHCO 3 buffer solution (pH 8.0-12.0). This method is based on the enhanced ECL of luminol-sibutramine. Meanwhile, in order to overcome the drawbacks of conventional cells, a FI cell was designed, which is reusable and has a great improvement in sensitivity and selectivity for ECL analysis. Under the optimal experimental conditions, the enhanced ECL intensity was linearly related to the concentration of sibutramine in the range 1.0x10 -8 -1.0x10 -6 g mL -1 with a detection limit of 2.48x10 -9 g mL -1 and a correlation coefficient (R) of 0.9995. The relative standard deviation (RSD) for 1.0x10 -7 g mL -1 samples was 2.1% (n=11). The possible mechanism discussed. The proposed FI-ECL method has been successfully applied to the determination of sibutramine in diet pill samples. - Highlights: → An electrochemiluminescence (ECL) system was studied to determine sibutramine. → A flow injection cell was made to overcome the drawbacks of the conventional ones. → The system was based on the enhanced ECL of luminol-sibutramine. → The system can be satisfactorily applied to determine sibutramine in diet pills.

  1. Determination of sibutramine with a new sensor based on luminol electrochemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Wang Shaowei [Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China); Yu Jinghua, E-mail: wangshaowei119@hotmail.co [Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China); Wan Fuwei; Ge Shenguang; Yan Mei; Zhang Meng [Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022 (China)

    2011-07-15

    A flow injection electrochemiluminescence (FI-ECL) analysis method for the determination of sibutramine in the presence of luminol was studied under conventional cyclic voltammetry in alkaline Na{sub 2}CO{sub 3}-NaHCO{sub 3} buffer solution (pH 8.0-12.0). This method is based on the enhanced ECL of luminol-sibutramine. Meanwhile, in order to overcome the drawbacks of conventional cells, a FI cell was designed, which is reusable and has a great improvement in sensitivity and selectivity for ECL analysis. Under the optimal experimental conditions, the enhanced ECL intensity was linearly related to the concentration of sibutramine in the range 1.0x10{sup -8}-1.0x10{sup -6} g mL{sup -1} with a detection limit of 2.48x10{sup -9} g mL{sup -1} and a correlation coefficient (R) of 0.9995. The relative standard deviation (RSD) for 1.0x10{sup -7} g mL{sup -1} samples was 2.1% (n=11). The possible mechanism discussed. The proposed FI-ECL method has been successfully applied to the determination of sibutramine in diet pill samples. - Highlights: {yields} An electrochemiluminescence (ECL) system was studied to determine sibutramine. {yields} A flow injection cell was made to overcome the drawbacks of the conventional ones. {yields} The system was based on the enhanced ECL of luminol-sibutramine. {yields} The system can be satisfactorily applied to determine sibutramine in diet pills.

  2. A kinetic study of the enhancement of solution chemiluminescence of glyoxylic acid oxidation by manganese species.

    Science.gov (United States)

    Otamonga, Jean-Paul; Abdel-Mageed, Amal; Agater, Irena B; Jewsbury, Roger A

    2015-08-01

    In order to study the mechanism of the enhancement of solution chemiluminescence, the kinetics of the decay of the oxidant and the chemiluminescence emission were followed for oxidations by permanganate, manganese dioxide sol and Mn(3+) (aq) of glyoxylic acid, using stopped-flow spectrophotometry. Results are reported for the glyoxylic acid oxidized under pseudo first-order conditions and in an acidic medium at 25 °C. For permanganate under these conditions, the decay is sigmoidal, consistent with autocatalysis, and for manganese dioxide sol and Mn(3+) it is pseudo first order. The effects of the presence of aqueous formaldehyde and Mn(2+) were observed and a fit to a simple mechanism is discussed. It is concluded that chemiluminescent enhancement in these systems is best explained by reaction kinetics. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Phenylboronic acid immunoaffinity reactor coupled with flow injection chemiluminescence for determination of {alpha}-fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Wu Yafeng [Jiangsu Provincial Key Lab of Biomaterials and Biodevices, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210096 (China); Zhuang Yafeng [Department of Chemistry, Changzhou Institute of Technology, Changzhou 213022 (China); Liu Songqin [Jiangsu Provincial Key Lab of Biomaterials and Biodevices, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210096 (China)], E-mail: liusq@seu.edu.cn; He Lin [Department of Chemistry, North Carolina State University, Raleigh, NC 27695-8204 (United States)

    2008-12-23

    A reusable and sensitive immunoassay based on phenylboronic acid immunoaffinity reactor in combination with flow injection chemiluminescence (CL) for determination of glycoprotein was described. The reactor was fabricated by immobilizing 3-aminophenylboronic acid (APBA) on glass microbeads with {gamma}-glycidoxypropyltrimethoxysilane (GPMS) as linkage. The {alpha}-fetoprotein (AFP) could be easily immobilized on the APBA coated beads through sugar-boronic interaction. After an off-line incubation, the mixture of the analyte AFP with horseradish peroxidase-labeled AFP antibody (HRP-anti-AFP) was injected into the reactor. This led the trapping of free HRP-anti-AFP by the surface coated AFP on glass beads. The trapped HRP-anti-AFP was detected by chemiluminescence due to its sensitizing effect on the reaction of luminol and hydrogen peroxide. Under optimal conditions, the chemiluminescent signal was proportional to AFP concentration in the range of 10-100 ng mL{sup -1}. The whole assay process including regeneration of the reactor could be completed within 31 min. The proposed system showed acceptable detection and fabrication reproducibility, and the results obtained with the present method were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. The described method enabled a low-cost, time saving and was potential to detect the serum AFP level in clinical diagnosis.

  4. A competitive immunoassay for sensitive detection of small molecules chloramphenicol based on luminol functionalized silver nanoprobe.

    Science.gov (United States)

    Yu, Xiuxia; He, Yi; Jiang, Jie; Cui, Hua

    2014-02-17

    Chloramphenicol (CHL) as a broad-spectrum antibiotic has a broad action spectrum against Gram-positive and Gram-negative bacteria, as well as anaerobes. The use of CHL is strictly restricted in poultry because of its toxic effect. However, CHL is still illegally used in animal farming because of its accessibility and low cost. Therefore, sensitive methods are highly desired for the determination of CHL in foodstuffs. The immunoassays based on labeling as an important tool have been reported for the detection of CHL residues in food-producing animals. However, most of the labeling procedures require multi-step reactions and purifications and thus they are complicated and time-consuming. Recently, in our previous work, luminol functionalized silver nanoparticles have been successfully synthesized, which exhibits higher CL efficiency than luminol functionalized gold nanoparticles. In this work, the new luminol functionalized silver nanoparticles have been used for the labeling of small molecules CHL for the first time and a competitive chemiluminescent immunoassay has been developed for the detection of CHL. Owing to the amplification of silver nanoparticles, high sensitivity for CHL could be achieved with a low detection limit of 7.6×10(-9) g mL(-1) and a wide linear dynamic range of 1.0×10(-8)-1.0×10(-6) g mL(-1). This method has also been successfully applied to determine CHL in milk and honey samples with a good recoveries (92% and 102%, 99% and 107% respectively), indicating that the method is feasible for the determination of CHL in real milk and honey samples. The labeling procedure is simple, convenient and fast, superior to previously reported labeling procedures. The immunoassay is also simple, fast, sensitive and selective. It is of application potential for the determination of CHL in foodstuffs. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Determination of monoamine neurotransmitters and their metabolites in a mouse brain microdialysate by coupling high-performance liquid chromatography with gold nanoparticle-initiated chemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Li Na; Guo Jizhao; Liu Bo; Yu Yuqi [Department of Chemistry, University of Science and Technology of China (USTC), JinZhai Road No: 96, 230026 Hefei, Anhui (China); Cui Hua, E-mail: hcui@ustc.edu.cn [Department of Chemistry, University of Science and Technology of China (USTC), JinZhai Road No: 96, 230026 Hefei, Anhui (China); Mao Lanqun; Lin Yuqing [Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences (CAS), 100080 Beijing (China)

    2009-07-10

    Our previous work showed that gold nanoparticles could trigger chemiluminescence (CL) between luminol and AgNO{sub 3}. In the present work, the effect of some biologically important reductive compounds, including monoamine neurotransmitters and their metabolites, reductive amino acids, ascorbic acid, uric acid, and glutathione, on the novel CL reaction were investigated for analytical purpose. It was found that all of them could inhibit the CL from the luminol-AgNO{sub 3}-Au colloid system. Among them, monoamine neurotransmitters and their metabolites exhibited strong inhibition effect. Taking dopamine as a model compound, the CL mechanism was studied by measuring absorption spectra during the CL reaction and the reaction kinetics via stopped-flow technique. The CL inhibition mechanism is proposed to be due to that these tested compounds competed with luminol for AgNO{sub 3} to inhibit the formation of luminol radicals and to accelerate deposition of Ag atoms on surface of gold nanoparticles, leading to a decrease in CL intensity. Based on the inhibited CL, a novel method for simultaneous determination of monoamine neurotransmitters and their metabolites was developed by coupling high-performance liquid chromatography with this CL reaction. The new method was successfully applied to determine the compounds in a mouse brain microdialysate. Compared with the reported HPLC-CL methods, the proposed method is simple, fast, and could determine more analytes. Moreover, the limits of linear ranges for NE, E, and DA using the proposed method were one order of magnitude lower than the luminol system without gold nanoparticles.

  6. Determination of monoamine neurotransmitters and their metabolites in a mouse brain microdialysate by coupling high-performance liquid chromatography with gold nanoparticle-initiated chemiluminescence

    International Nuclear Information System (INIS)

    Li Na; Guo Jizhao; Liu Bo; Yu Yuqi; Cui Hua; Mao Lanqun; Lin Yuqing

    2009-01-01

    Our previous work showed that gold nanoparticles could trigger chemiluminescence (CL) between luminol and AgNO 3 . In the present work, the effect of some biologically important reductive compounds, including monoamine neurotransmitters and their metabolites, reductive amino acids, ascorbic acid, uric acid, and glutathione, on the novel CL reaction were investigated for analytical purpose. It was found that all of them could inhibit the CL from the luminol-AgNO 3 -Au colloid system. Among them, monoamine neurotransmitters and their metabolites exhibited strong inhibition effect. Taking dopamine as a model compound, the CL mechanism was studied by measuring absorption spectra during the CL reaction and the reaction kinetics via stopped-flow technique. The CL inhibition mechanism is proposed to be due to that these tested compounds competed with luminol for AgNO 3 to inhibit the formation of luminol radicals and to accelerate deposition of Ag atoms on surface of gold nanoparticles, leading to a decrease in CL intensity. Based on the inhibited CL, a novel method for simultaneous determination of monoamine neurotransmitters and their metabolites was developed by coupling high-performance liquid chromatography with this CL reaction. The new method was successfully applied to determine the compounds in a mouse brain microdialysate. Compared with the reported HPLC-CL methods, the proposed method is simple, fast, and could determine more analytes. Moreover, the limits of linear ranges for NE, E, and DA using the proposed method were one order of magnitude lower than the luminol system without gold nanoparticles.

  7. A sensitive chemiluminescent immunoassay to detect Chromotrope FB (Chr FB) in foods.

    Science.gov (United States)

    Xu, Kun; Long, Hao; Xing, Rongge; Yin, Yongmei; Eremin, Sergei A; Meng, Meng; Xi, Rimo

    2017-03-01

    Chromotrope FB (Chr FB) is a synthetic azo dye permitted for use in foods and medicines. An acceptable daily intake (ADI) of Chr FB was 0-0.5mg/kg in China. In this study, we synthesized a Chr FB hapten with an amino group to prepare its artificial immunogen. Polyclonal antibodies obtained from New Zealand rabbits were applied to develop an indirect competitive chemiluminescent immunoassay (icCLIA) to detect Chr FB in foods. A horseradish peroxidase (HRP)-luminol-H 2 O 2 system was used to yield CL signal with p-iodophenol as an enhancement reagent. The method showed good specificity towards Chr FB and could detect as low as 0.02ngmL -1 Chr FB in buffer, 0.07ngg -1 in yoghurt candy, 0.07ngg -1 in vitamin drink and 0.13ngg -1 in bread. Compared with HPLC method, the proposed method is more sensitive by two orders of magnitude. The accuracy and precision of this method are acceptable and comparable with HPLC method. Therefore, the proposed method could be used for rapid screening of Chr FB in the mentioned foodstuffs. Copyright © 2016. Published by Elsevier B.V.

  8. Luminol/CdTe quantum dots/sodium periodate system in conjunction with response-surface methodology for chemiluminometric determination of some tetracyclines

    Energy Technology Data Exchange (ETDEWEB)

    Imani-Nabiyyi, Amin; Sorouraddin, Mohammad H., E-mail: soruraddin@tabrizu.ac.ir; Amjadi, Mohammad; Naseri, Abdolhossein

    2014-07-01

    A simple and sensitive chemiluminometric method is described for the determination of tetracycline (TC) and oxytetracycline (OTC) in their hydrochloride form on the basis of drastic enhancement of the chemiluminescence (CL) from the luminol/L-cysteine-capped CdTe quantum dots (QDs)/sodium periodate system, caused by the presence of TC and OTC hydrochloride. The method uses pH value at which tetracyclines have proven to be stable. Response surface methodology was exploited for optimizing the experimental conditions. The synthesized QDs were characterized by means of X-ray diffraction (XRD), transmission electron microscopy (TEM), UV–vis spectroscopy, and photoluminescence spectroscopy. A possible mechanism of the CL system was proposed based on the CL spectra and the effect of some specific radical-scavengers on the system. Under the optimum conditions linear dynamic ranges of 5.0×10{sup −8}–6.0×10{sup −6} mol L{sup −1} and 5.0×10{sup −8}–8.0×10{sup −6} mol L{sup −1} were observed for TC and OTC, respectively with corresponding detection limits of 2.2×10{sup −8} mol L{sup −1} and 3.0×10{sup −8} mol L{sup −1}. The precision (RSD%) for five replicate determinations of TC and OTC were respectively no more than 3.4% and 4.0%. The method was satisfactorily applied to the determination of TC.HCl and OTC.HCl in water samples, pharmaceutical formulations, and honey. - Highlights: • A simple, rapid, and sensitive method for determination of some tetracyclines. • Enhancement of CL of luminol/Cys-capped CdTe QDs/NaIO{sub 4} with TC.HCl and OTC.HCl. • No need to chemical, photochemical, or any peculiar pretreatment of the samples. • Measuring the analytes in conditions at which they are stable. • Capable of measuring TCs in pharmaceutical, water, and honey samples.

  9. The importance of chain length for the polyphosphate enhancement of acidic potassium permanganate chemiluminescence.

    Science.gov (United States)

    Holland, Brendan J; Adcock, Jacqui L; Nesterenko, Pavel N; Peristyy, Anton; Stevenson, Paul G; Barnett, Neil W; Conlan, Xavier A; Francis, Paul S

    2014-09-09

    Sodium polyphosphate is commonly used to enhance chemiluminescence reactions with acidic potassium permanganate through a dual enhancement mechanism, but commercially available polyphosphates vary greatly in composition. We have examined the influence of polyphosphate composition and concentration on both the dual enhancement mechanism of chemiluminescence intensity and the stability of the reagent under analytically useful conditions. The average chain length (n) provides a convenient characterisation, but materials with similar values can exhibit markedly different distributions of phosphate oligomers. There is a minimum polyphosphate chain length (∼6) required for a large enhancement of the emission intensity, but no further advantage was obtained using polyphosphate materials with much longer average chain lengths. Providing there is a sufficient average chain length, the optimum concentration of polyphosphate is dependent on the analyte and in some cases, may be lower than the quantities previously used in routine detection. However, the concentration of polyphosphate should not be lowered in permanganate reagents that have been partially reduced to form high concentrations of the key manganese(III) co-reactant, as this intermediate needs to be stabilised to prevent formation of insoluble manganese(IV). Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay

    Science.gov (United States)

    Shi, Jing; Xu, Mingxia; Tang, Qinghui; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-02-01

    A novel flow injection chemiluminescence immunoassay for simple, sensitive and low-cost detection of diclofenac was established based on specific binding of antigen and antibody. Carboxylic resin beads used as solid phase carrier materials provided good biocompatibility and large surface-to-volume ratio for modifying more coating antigen. There was a competitive process between the diclofenac in solution and the immobilized coating antigen to react with the limited binding sites of the polyclonal antibody to form the immunocomplex. The second antibody labelled with horseradish peroxidase was introduced into the immunosensor and trapped by captured polyclonal antibody against diclofenac, which could effectively amplify chemiluminescence signals of luminol-PIP-H2O2. Under optimal conditions, the diclofenac could be detected quantitatively. The chemiluminescence intensity decreased linearly with the logarithm of the diclofenac concentration in the range of 0.1-100 ng mL- 1 with a detection limit of 0.05 ng mL- 1 at a signal-to-noise ratio of 3. The immunosensor exhibited high sensitivity, specificity and acceptable stability. This easy-operated and cost-effective analytical method could be valuable for the diclofenac determination in real water samples.

  11. A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.

    Science.gov (United States)

    Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying

    2014-08-15

    Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. An ultrasensitive chemiluminescence immunoassay for fumonisin B1 detection in cereals based on gold-coated magnetic nanoparticles.

    Science.gov (United States)

    Jie, Mingsha; Yu, Songcheng; Yu, Fei; Liu, Lie; He, Leiliang; Li, Yanqiang; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B; Wu, Yongjun

    2018-07-01

    In the present study, a novel highly sensitive magnetic enzyme chemiluminescence immunoassay (MECLIA) was developed to detect fumonisin B 1 (FB 1 ) in cereal samples. The gold-coated magnetic nanoparticles (Fe 3 O 4 @Au, GoldMag) were used as solid phase carrier to develop a competitive CLIA for detecting FB 1 , in which FB 1 in samples would compete with FB 1 -ovalbumin coated on the surface of Fe 3 O 4 @Au nanoparticles for binding with FB 1 antibodies. Successively, horseradish peroxidase labeled goat anti-rabbit IgG (HRP-IgG) was conjugated with FB 1 antibodies on the microplate. In substrate solution containing luminol and H 2 O 2 , HRP-IgG catalyzed luminol oxidation by H 2 O 2 , generating a high chemiluminescence signal. The FB 1 immune GoldMag particles were characterized by Fourier transform infrared spectroscopy, scanning electron microscope and zeta potential analysis, etc. RESULTS: The concentrations and the reaction times of these immunoreagents were optimized to improve the performances of this method. The established method could detect as low as 0.027 ng mL -1 FB 1 from 0.05 ng mL -1 to 25 ng mL -1 , demonstrating little cross-reaction (less than 2.4%) with other structurally related compounds. The average intrassay relative SD (RSD) (n = 6) was 3.4% and the average interassay RSD (n = 6) was 5.4%. This method was successfully applied for the determination of FB 1 in corn and wheat and gave recoveries of between 98-110% and 91-105%, respectively. The results of the present study suggest that the MECLIA approach has potential application for high-throughput fumonisin screening in cereals. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  13. Characterization of the response chemiluminescence of neutrophils human beings to the hemolysin Escherichia coli alpha

    International Nuclear Information System (INIS)

    Garcia, J.

    2000-01-01

    Escherichia coli alpha hemolysin (AH) evoked a luminol-amplified chemiluminescence (CL) response from human polymorphonuclear leukocytes (PMN). Analysis of kinetic parameters of the PMN CL response to AH established similarities with that of PMN to the calcium ionophore A23187. PMN CL responses to both AH and A23187 were equally decreased by preincubating PMN with A63612, a hidroxamic acid derivative and lipooxigenase inhibitor, showing that the CL response to both hemolysin and ionophore share a common mechanism, probably activation of leukotriene synthesis, due to calcium entry into the cells brought about by AH and A23187. In addition, the CL response of PMN to AH was lowered by the hydroxyl radical scavenger dimethyl sulfoxide, further suggesting arachidonate metabolism is involved in CL response. (Author) [es

  14. Preparation of enhanced hydrophobic poly(L-lactide-co-ε-caprolactone) films surface and its blood compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Il; Lim, Jin Ik; Jung, Youngmee; Mun, Cho Hay [Division of Life and Health Science, Biomaterials Research Center, Korea Institute of Science and Technology, Seoul (Korea, Republic of); Kim, Ji Heung, E-mail: kimjh@skku.edu [Department of Chemical Engineering, Polymer Technology Institute, Sungkyunkwan University, Suwon, Kyunggi (Korea, Republic of); Kim, Soo Hyun, E-mail: soohkim@kist.re.kr [Division of Life and Health Science, Biomaterials Research Center, Korea Institute of Science and Technology, Seoul (Korea, Republic of); KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul (Korea, Republic of)

    2013-07-01

    Hydrophobicity-enhanced poly(L-lactide-co-ε-caprolactone) (PLCL) (50:50) films were cast by using the solvent–nonsolvent casting method. PLCL (50:50) was synthesized by the well-known random copolymerization process and confirmed by {sup 1}H NMR analysis. The molecular weight of the synthesized PLCL was measured by gel permeation chromatography (GPC). Number-average (Mn), weight-average (Mw) molecular weights and polydispersity (Mw/Mn) were 7 × 10{sup 4}, 1.2 × 10{sup 5}, and 1.7, respectively. PLCL films were cast in vacuum condition with various nonsolvents and nonsolvent ratios. Tetrahydrofuran (THF) was used as the solvent and three different alcohols were used as the nonsolvent: methanol, ethanol, and isopropyl alcohol (IPA). Surface hydrophobicity was confirmed by water contact angle. The water contact angle was increased from 81° ± 2° to 107° ± 2°. Water contact angle was influenced by surface porosity and topography. The prepared film surfaces were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The change of crystalline property was characterized by X-ray diffraction (XRD). Platelet adhesion tests on the modified PLCL film surfaces were evaluated by platelet-rich plasma (PRP). The modified film surface exhibited enhanced hydrophobicity and reduced platelet adhesion ratio depending on the surface topography. One of the candidate products proposed as a potential blood compatible material showed a markedly reduced platelet adhesion property.

  15. Application of forensic luminol for blood detection in endodontic files

    Directory of Open Access Journals (Sweden)

    Rodrigo ARRUDA-VASCONCELOS

    Full Text Available Abstract Introduction Blood is a biological material with high potential of infectious transmission in dental environments, including herpes simplex, hepatitis and AIDS. Aim To investigate the efficacy of luminol in detecting blood in endodontic files before and after the sterilization process. Material and method Luminol was used to investigate the presence or absence of traces of blood tissue in 50 endodontic files, visible to naked eye or not, after performing endodontic treatment and after the cleaning/sterilization process. The results obtained were tabulated and statistically analyzed by using the Friedman’s test at a significance level of 5% (p<0.05. Result By naked eye, it was found that 31/50 files showed no trace of blood, 8/50 showed a slight presence of blood and 11/50 showed a considerable presence of blood after endodontic treatment. After the use of luminol, however, 16/50 endodontic files showed no trace of blood, 19/50 showed a slight presence of blood and 15/50 showed a considerable presence of blood. After the cleaning and sterilization process, no blood was detected in the files. Conclusion It was concluded that the luminol solution is effective in detecting blood tissue in endodontic files as well as in validating the cleaning/sterilization process.

  16. Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads

    International Nuclear Information System (INIS)

    Zhang Ruiq; Nakajima, Hizuru; Soh, Nobuaki; Nakano, Koji; Masadome, Takashi; Nagata, Kazumi; Sakamoto, Kazuhira; Imato, Toshihiko

    2007-01-01

    A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm

  17. Multifunctional reduced graphene oxide trigged chemiluminescence resonance energy transfer: Novel signal amplification strategy for photoelectrochemical immunoassay of squamous cell carcinoma antigen.

    Science.gov (United States)

    Zhang, Yan; Sun, Guoqiang; Yang, Hongmei; Yu, Jinghua; Yan, Mei; Song, Xianrang

    2016-05-15

    Herein, a photoelectrochemical (PEC) immunoassay is constructed for squamous cell carcinoma antigen (SCCA) detection using zinc oxide nanoflower-bismuth sulfide (Bi2S3) composites as photoactive materials and reduced graphene oxide (rGO) as signal labels. Horseradish peroxidase is used to block sites against nonspecific binding, and then participated in luminol-based chemiluminescence (CL) system. The induced CL emission is acted as an inner light source to excite photoactive materials, simplifying the instrument. A novel signal amplification strategy is stem from rGO because of the rGO acts as an energy acceptor, while luminol serves as a donor to rGO, triggering the CL resonance energy transfer phenomenon between luminol and rGO. Thus, the efficient CL emission to photoactive materials decreases. Furthermore, the signal amplification caused by rGO labeled signal antibodies is related to photogenerated electron-hole pairs: perfect matching of energy levels between rGO and Bi2S3 makes rGO a sink to capture photogenerated electrons from Bi2S3; the increased steric hindrance hinders the electron donor to the surface of Bi2S3 for reaction with the photogenerated holes. On the basis of the novel signal amplification strategy, the proposed immunosensor exhibits excellent analytical performance for PEC detection of SCCA, ranging from 0.8 pg mL(-1) to 80 ng mL(-1) with a low detection limit of 0.21 pg mL(-1). Meanwhile, the designed signal amplification strategy provides a general format for future development of PEC assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Paramecium caudatum as a source of nitric oxide: Chemiluminescent detection based on Bluestar® Forensic reagent connected with microdialysis.

    Science.gov (United States)

    Bancirova, Martina

    2017-11-01

    Nitric oxide (NO) chemistry inside the body is the most interesting part of its behavior. NO is involved in controlling blood pressure, and in transmitting nerve signals and a variety of other signaling processes. To explain the behavior of NO, it is necessary to determine its immediate concentration or observe time-dependent changes in its concentration. In Paramecium caudatum, NO is formed by calcium-dependent nNOS (NOS1)-like protein, which is distributed in the cytoplasm. NO synthesis affects the ciliary beat and consequent motility of cells and blocked NO synthesis reduces the ability of cells to move. The possibility of online coupling of microdialysis (of P. caudatum solution) with NO detection is demonstrated. Direct measurement of NO is carried out using dilute Bluestar ® Forensic reagent (luminol-H 2 O 2 system; one of the NO detections is based upon the chemiluminescent reaction between NO and the luminol-H 2 O 2 system, which is specifically reactive to NO). The effect of a nitric oxide synthase inhibitor, NG-nitro-l-arginine methyl ester was observed. NO production was inhibited and the movement of P. caudatum was restricted. These effects were time dependent and after a specific time were reversed. Copyright © 2017 John Wiley & Sons, Ltd.

  19. PLCL1 rs7595412 variation is not associated with hip bone size variation in postmenopausal Danish women

    Directory of Open Access Journals (Sweden)

    Karsdal Morten A

    2009-12-01

    Full Text Available Abstract Background Bone size (BS variation is under strong genetic control and plays an important role in determining bone strength and fracture risk. Recently, a genome-wide association study identified polymorphisms associated with hip BS variation in the PLCL1 (phospholipase c-like 1 locus. Carriers of the major A allele of the most significant polymorphism, rs7595412, have around 17% larger hip BS than non-carriers. We therefore hypothesized that this polymorphism may also influence postmenopausal complications. Methods The effects of rs7595412 on hip BS, bone mineral density (BMD, vertebral fractures, serum Crosslaps and osteocalcin levels were analyzed in 1,191 postmenopausal Danish women. Results This polymorphism had no influence on hip and spine BS as well as on femur and spine BMD. Women carrying at least one copy of the A allele had lower levels of serum osteocalcin as compared with those homozygous for the G allele (p = 0.03 whereas no effect on serum Crosslaps was detected. Furthermore, women homozygous for the A allele were more affected by vertebral fractures than those carrying at least one copy of the G allele (p = 0.04. Conclusions In postmenopausal women, our results suggest that the PLCL1 rs7595412 polymorphism has no obvious effect on hip BS or BMD but may be nominally associated with increased proportion of vertebral fracture and increased levels of osteocalcin.

  20. A multisyringe flow injection system with immobilized glucose oxidase based on homogeneous chemiluminescence detection

    International Nuclear Information System (INIS)

    Manera, Matias; Miro, Manuel; Estela, Jose Manuel; Cerda, Victor

    2004-01-01

    In this paper, enzyme containing reactors are for the first time implemented in the multisyringe flow injection analysis (MSFIA) technique interfaced with chemiluminescence detection for biochemical assays. The automated methodology is based on the on-line substrate conversion in an oxidase packed-bed reactor and the post-column chemiluminogenic catalysed-reaction of the generated oxidising species with an organic molecule (namely, 3-aminophthalhydrazide) in front of the photosensor module. Various catalysts in homogeneous phase are compared taking advantage of the benefits of the MSFIA concept. On one hand, mineral catalysts (namely, Co(II)) are assessed, on the other hand, minute and accurate volumes of soluble organic species (viz., horseradish peroxidase (HRP)) are readily handled without requiring further immobilization protocols. The potentials of the MSFIA-CL concept with immobilisation of the proper oxidase protein are demonstrated using glucose as a model of substrate. Despite the different pH and kinetic requirements for both the substrate conversion in the enzyme-reactor and the Co(II)/HRP-mediated luminol oxidation integrated in the flow system, the MSFIA approach warrants maximum yields owing to the independent optimisation of the physical and chemical parameters of the various reactions involved. Under the optimised configurations and experimental variables, dynamic working ranges from 2.5x10 -6 to 1.0x10 -3 mol l -1 glucose may be obtained for both detection schemes by proper photomultiplier gain selection. The detection and determination limits calculated at the 3σ and 10σ level were 8.6x10 -7 and 2.0x10 -6 mol l -1 glucose, respectively, for the Co(II)-luminol system, and 1.3x10 -6 and 2.3x10 -6 mol l -1 glucose, respectively, for the HRP-luminol procedure. The repeatability (n=10) at the 1.0x10 -5 mol l -1 level was slightly better for the Co(II)-catalysed reaction (2.5% versus 4.0%). The developed MSFIA-CL methodology was used for kinetic

  1. The alpha hemolysin of Escherichia Coli power the metabolism oxidative of neutrophils human beings in response to the peptide chemotactic FMLP: comparison with the ionophore of calcium A23187

    International Nuclear Information System (INIS)

    Garcia, J.

    2000-01-01

    The calcium ionophore ionomycin primes polymorphonuclear leukocytes (PMN) for increased superoxide production upon stimulation with the chemotactic peptide FMLP (Helman Finkel, T. et al J Biol Chem 1987; 262: 12589-12596) In this investigation we assessed the effect of PMN priming with either alpha hemolysin (AH) or the calcium ionophore A23187, both of which increase intracellular calcium, on the oxidative metabolism of PMN (as measured by chemiluminescence) in response to secondary stimulation with FMLP. Both A23187 and AH priming increased, the luminol-enhanced chemiluminescence in response to secondary stimulation with FMLP, indicating overstimulation of PMLP oxidative metabolism. Additional experiments using lucigenin as chemiluminescence enhancer showed that A23187, but not AH priming of PMN, increased superoxide release in a manner similar to that reported for ionomycin. These results are discussed in reference to infectious processes involving hemolytic E. coli (Author) [es

  2. Assessment of antioxidant activity of spray dried extracts of Psidium guajava leaves by DPPH and chemiluminescence inhibition in human neutrophils.

    Science.gov (United States)

    Fernandes, M R V; Azzolini, A E C S; Martinez, M L L; Souza, C R F; Lucisano-Valim, Y M; Oliveira, W P

    2014-01-01

    This work evaluated the physicochemical properties and antioxidant activity of spray dried extracts (SDE) from Psidium guajava L. leaves. Different drying carriers, namely, maltodextrin, colloidal silicon dioxide, Arabic gum, and β -cyclodextrin at concentrations of 40 and 80% relative to solids content, were added to drying composition. SDE were characterized through determination of the total phenolic, tannins, and flavonoid content. Antioxidant potential of the SDE was assessed by two assays: cellular test that measures the luminol-enhanced chemiluminescence (LumCL) produced by neutrophils stimulated with phorbol myristate acetate (PMA) and the DPPH radical scavenging (DPPH∗ method). In both assays the antioxidant activity of the SDE occurred in a concentration-dependent manner and showed no toxicity to the cells. Using the CLlum method, the IC50 ranged from 5.42 to 6.50 µg/mL. The IC50 of the SDE ranged from 7.96 to 8.11 µg/mL using the DPPH(•) method. Psidium guajava SDE presented significant antioxidant activity; thus they show high potential as an active phytopharmaceutical ingredient. Our findings in human neutrophils are pharmacologically relevant since they indicate that P. guajava SDE is a potential antioxidant and anti-inflammatory agent in human cells.

  3. Adaptation of a load-inject valve for a flow injection chemiluminescence system enabling dual-reagent injection enhances understanding of environmental Fenton chemistry

    International Nuclear Information System (INIS)

    Jones, Matthew R.; Nightingale, Philp D.; Turner, Suzanne M.; Liss, Peter S.

    2013-01-01

    Graphical abstract: -- Highlights: •Measurement of multiple components of Fenton chemistry; Fe(II) and H 2 O 2 . •Rapid, quasi-simultaneous analysis enables calculation of environmental kinetics. •Low, nano to pico-molar detection limits with dual analyte analysis. •Able to measure complex matrix samples – organically enriched seawater. •Low cost system with appreciable sensitivity compared to single analyte analysis. -- Abstract: Environmental Fenton chemistry has been poorly constrained within the marine environment at a multi-component level. A simple, unique, reconfiguration of a flow-injection analytical system combined with luminol chemiluminescence allows quasi-simultaneously the measurement, using a single load-inject valve and a single photon multiplier tube, of reduced iron, Fe(II), and hydrogen peroxide. The system enables rapid, every 22 s, measurements with good accuracy at environmentally relevant concentrations, less than 5% relative standard deviations on both a 5 nM Fe(II) standard and a 60 nM hydrogen peroxide standard. Limits of detection were as low as 40 pM Fe(II) and 100 pM hydrogen peroxide. The system showed excellent capability by measuring from within an organic rich seawater the photochemically induced production of Fe(II) and hydrogen peroxide and their subsequent cycling and Fenton like interactions

  4. Study on the luminescence behavior of sulfobutylether-β-cyclodextrin with risperidone and its analytical application.

    Science.gov (United States)

    Wu, Min; Chen, Donghua; Song, Zhenghua

    2012-10-01

    The interaction of sulfobutylether-β-cyclodextrin (SBE-β-CD) with risperidone (RISP) was first described with luminol-SBE-β-CD chemiluminescence (CL) system by flow injection analysis (FIA). In luminol-SBE-β-CD CL system, the 1:1 SBE-β-CD···luminol(*) complexation could enhance CL intensity of luminol and produce the effect of complexation enhancement of CL (CEC). It was found that RISP could quench the CL intensity of SBE-β-CD···luminol(*) and caused the effect of complexation enhancement of quenching (CEQ), the formation constant K(R-CD) 3.4×10(4) L mol(-1) and the stoichiometric ratio 1:1 of RISP···SBE-β-CD complex were obtained by the proposed CL model. Association degree α 0.036 of RISP···SBE-β-CD complex was also given by CL method. Based on the linear relationship to the decrement of luminol-SBE-β-CD-RISP CL intensity and the logarithm of RISP concentration, RISP also can be quantified in the linear range of 3.0-500.0 nmol L(-1) with a detection limit of 1.0 nmol L(-1) (3σ). The proposed method was successfully applied to monitoring excreted RISP in human urine. It was found that RISP reached its maximum after oral administration for 1.5 h with the total excretion of 14.26% within 8.5 h; the elimination rate constant k and half-life time t(1/2) were 0.474 and 1.5 h, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Application of chemiluminescence to the study of alpha, beta and gamma radiolysis of water

    International Nuclear Information System (INIS)

    Broudic, V.; Muzeau, B.; Jegou, C.; Bonnal, M.; Gavazzi, A.; Marques, C.

    2004-01-01

    In the frame of the French research program on the long-term behavior of spent nuclear fuel, experiments are conducted in ATALANTE to develop and validate models of spent fuel evolution in contact with an aqueous phase. One of the mechanisms that may govern intermediate or long-term alteration of the spent fuel matrix in a repository is the oxidizing dissolution by radiolysis products of water. Leaching experiments in de-aerated media requires the analysis of hydrogen peroxide, as a major product of water radiolysis, down to 10 -8 mol.L -1 . This work presents the results obtained using the chemiluminescence reaction of iso-luminol with H 2 O 2 , catalyzed by micro-peroxidase. Depending on the samples used, different types of radiolytic processes were studied: α radiolysis of water when leaching UO 2 pellets doped with alpha emitters, or γ radiolysis of water when leaching the same samples or spent fuel in a gamma field. Influences of operating conditions on the analytical results are discussed. (authors)

  6. Enhanced sensitivity of Cypridina luciferin analog (CLA) chemiluminescence for the detection of O2- with non ionic detergents

    NARCIS (Netherlands)

    Osman, A.M.; Laane, C.; Hilhorst, R.

    2000-01-01

    Superoxide anion-triggered chemiluminescence of Cypridina luciferin analogue (CLA), 2-methyl-6-phenyl-3,7-dohydroimidazo[1,2-]pyrazin-3-one, is enhanced by non-ionic detergents such as Tween 20, Triton X-100 and Tween 80. At the concentration of 0.6øv/v) the largest increase (2.7-fold) of CLA light

  7. DNA imaging and quantification using chemi-luminescent probes

    International Nuclear Information System (INIS)

    Dorner, G.; Redjdal, N.; Laniece, P.; Siebert, R.; Tricoire, H.; Valentin, L.

    1999-01-01

    During this interdisciplinary study we have developed an ultra sensitive and reliable imaging system of DNA labelled by chemiluminescence. Based on a liquid nitrogen cooled CCD, the system achieves sensitivities down to 10 fg/mm 2 labelled DNA over a surface area of 25 x 25 cm 2 with a sub-millimeter resolution. Commercially available chemi-luminescent - and enhancer molecules are compared and their reaction conditions optimized for best signal-to-noise ratios. Double labelling was performed to verify quantification with radioactive probes. (authors)

  8. In situ-synthesized cadmium sulfide nanowire photosensor with a parylene passivation layer for chemiluminescent immunoassays.

    Science.gov (United States)

    Im, Ju-Hee; Kim, Hong-Rae; An, Byoung-Gi; Chang, Young Wook; Kang, Min-Jung; Lee, Tae-Geol; Son, Jin Gyeng; Park, Jae-Gwan; Pyun, Jae-Chul

    2017-06-15

    The direct in situ synthesis of cadmium sulfide (CdS) nanowires (NWs) was presented by direct synthesis of CdS NWs on the gold surface of an interdigitated electrode (IDE). In this work, we investigated the effect of a strong oxidant on the surfaces of the CdS NWs using X-ray photoelectron spectroscopy, transmission electron microscopy, and time-of-flight secondary ion mass spectrometry. We also fabricated a parylene-C film as a surface passivation layer for in situ-synthesized CdS NW photosensors and investigated the influence of the parylene-C passivation layer on the photoresponse during the coating of parylene-C under vacuum using a quartz crystal microbalance and a photoanalyzer. Finally, we used the in situ-synthesized CdS NW photosensor with the parylene-C passivation layer to detect the chemiluminescence of horseradish peroxidase and luminol and applied it to medical detection of carcinoembryonic antigen. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Electrochemiluminescence quenching of luminol by CuS in situ grown on reduced graphene oxide for detection of N-terminal pro-brain natriuretic peptide.

    Science.gov (United States)

    Li, Xiaojian; Lu, Peng; Wu, Bin; Wang, Yaoguang; Wang, Huan; Du, Bin; Pang, Xuehui; Wei, Qin

    2018-07-30

    A novel electrochemiluminescence (ECL) signal-off strategy based on CuS in situ grown on reduced graphene oxide (CuS-rGO) quenching luminol/H 2 O 2 system was firstly proposed. Luminol was grafted on the surface of Au@Fe 3 O 4 -Cu 3 (PO 4 ) 2 nanoflowers (Luminol-Au@Fe 3 O 4 -Cu 3 (PO 4 ) 2 ) which exhibited excellent catalytic effect towards the reduction of H 2 O 2 to enhance the ECL intensity of luminol. Cu 3 (PO 4 ) 2 nanoflowers showed large surface area which can immobilize more Fe 3 O 4 and Au nanoparticles. The quenching mechanism of CuS-rGO was due to ECL resonance energy transfer (RET). The spectral overlap between fluorescence spectrum of Luminol-Au@Fe 3 O 4 -Cu 3 (PO 4 ) 2 and UV-vis absorption spectrum of CuS-rGO revealed that resonance energy transfer was possible. Au nanoparticles were immobilized on the surface of CuS-rGO to capture secondary antibodies. After a sandwich-type immunoreaction, a remarkable decrease of ECL signal was observed. Under the optimal conditions, the immunosensor showed excellent performance for N-terminal pro-brain natriuretic peptide (NT-proBNP) detection with a wide detection range from 0.5 pg mL -1 to 20 ng mL -1 and a low detection limit of 0.12 pg mL -1 (S/N = 3). The prepared NT-proBNP immunosensor displayed high sensitivity, excellent stability and good specificity. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Assessment of Antioxidant Activity of Spray Dried Extracts of Psidium guajava Leaves by DPPH and Chemiluminescence Inhibition in Human Neutrophils

    Directory of Open Access Journals (Sweden)

    M. R. V. Fernandes

    2014-01-01

    Full Text Available This work evaluated the physicochemical properties and antioxidant activity of spray dried extracts (SDE from Psidium guajava L. leaves. Different drying carriers, namely, maltodextrin, colloidal silicon dioxide, Arabic gum, and β-cyclodextrin at concentrations of 40 and 80% relative to solids content, were added to drying composition. SDE were characterized through determination of the total phenolic, tannins, and flavonoid content. Antioxidant potential of the SDE was assessed by two assays: cellular test that measures the luminol-enhanced chemiluminescence (LumCL produced by neutrophils stimulated with phorbol myristate acetate (PMA and the DPPH radical scavenging (DPPH* method. In both assays the antioxidant activity of the SDE occurred in a concentration-dependent manner and showed no toxicity to the cells. Using the CLlum method, the IC50 ranged from 5.42 to 6.50 µg/mL. The IC50 of the SDE ranged from 7.96 to 8.11 µg/mL using the DPPH• method. Psidium guajava SDE presented significant antioxidant activity; thus they show high potential as an active phytopharmaceutical ingredient. Our findings in human neutrophils are pharmacologically relevant since they indicate that P. guajava SDE is a potential antioxidant and anti-inflammatory agent in human cells.

  11. Improvement on simultaneous determination of chromium species in aqueous solution by ion chromatography and chemiluminescence detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Liao, Y.P.; Jons, O.

    1997-01-01

    A sensitive method for the simultaneous determination of chromium(III) and chromium(VI) was chromatography and chemiluminescence detection. Two Dionex ion-exchange guard columns in series, CG5 and AG7, were used to separate chromium(III) from chromium(VI). Chromium(VI) was reduced by potassium......, the stabilities of reductant and luminol solutions were studied. The linear range of the calibration curve for chromium(III) and chromium(VI) was 1-400 mu g l(-1). The detection limit was 0.12 mu g l(-1) for chromium(III) and 0.09 mu g l(-1) for chromium(VI), respectively. The precision at the 20 mu g l(-1) level...... was 1.4% for chromium(III) and 2.5% for chromium(VI), respectively. The accuracy of the chromium(III) determination was determined by analysis of the NIST standard reference material 1643c, Trace elements in water with the result 19.1 +/- 1.0 mu g Cr(III) l(-1) (certified value 19.0 +/- 0.6 mu g Cr...

  12. A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples.

    Science.gov (United States)

    Vakh, Christina; Evdokimova, Ekaterina; Pochivalov, Aleksei; Moskvin, Leonid; Bulatov, Andrey

    2017-12-15

    An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol - N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10 -8 ·molL -1 (0.01mgkg -1 ) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Dual-readout Immunochromatographic Assay by Utilizing MnO2 Nanoflowers as the Unique Colorimetric/Chemiluminescent Probe

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Hui; Lu, Quian; Wang, Wenwen; Song, Yang; Tu, Xinman; Zhu, Chengzhou; Smith, Jordan N.; Du, Dan; Fu, Zhifeng; Lin, Yuehe

    2018-04-17

    Manganese dioxide nanoflowers (MnO2 NFs) were synthesized and utilized as a dual readout probe to develop a novel immunochromatographic test strip (ITS) for detecting pesticide residues using chlorpyrifos as the model analyte. MnO2 NFs-labeled antibody for chlorpyrifos was employed as the signal tracer for conducting the ITS. After 10-min competitive immunoreaction, the tracer antibody was captured by the immobilized immunogen on test line in the test strip, resulting in the accumulation of MnO2 NFs. The accumulation of MnO2 NFs led to the appearance of brown color on the test line, which could be easily observed by the naked eye as a qualitative readout. Moreover, MnO2 NFs showed a remarkably enhancing effect on the luminol-H2O2 chemiluminescent (CL) system. Unlike peroxidase-like nanomaterials, the enhancing mechanism of MnO2 NFs was based on its oxidant activity to decompose H2O2 for forming reactive oxygen species. After initiating the CL system in the test zone, strong CL signal was collected as a quantitative readout to sensitively detect chlorpyrifos. Under optimal conditions, the linear range of chlorpyrifos was 0.1–50 ng/mL with a low detection limit of 0.033 ng/mL (S/N = 3). The reliability of the dual-readout ITS was successfully demonstrated by the application on traditional Chinese medicine and environmental water samples. Due to the simultaneous rapid-qualitative and sensitive-quantitative detection, the dual-readout protocol provides a promising strategy for rapid screening and field assay on various areas such as environmental monitoring, food safety and point-of-care testing.

  14. Imaging Reactive Oxygen Species in Arthritis

    Directory of Open Access Journals (Sweden)

    Wei-Tsung Chen

    2004-07-01

    Full Text Available Reactive oxygen species (ROS have been shown to play a role in the pathogenesis of arthritides. Luminol was used as the primary reporter of ROS and photons resulting from the chemiluminescence reaction were detected using a super-cooled CCD photon counting system. Luminol was injected intravenously into groups of animals with different models of arthritis. Imaging signal correlated well with the severity of arthritis in focal and pan-arthritis as determined by histological measurement of ROS by formazan. Measurements were highly reproducible, sensitive, and repeatable. In vivo chemiluminescence imaging is expected to become a useful modality to elucidate the role of ROS in the pathogenesis of arthritides and in determining therapeutic efficacy of protective therapies.

  15. Encapsulation of Hemin in Metal-Organic Frameworks for Catalyzing the Chemiluminescence Reaction of the H2O2-Luminol System and Detecting Glucose in the Neutral Condition.

    Science.gov (United States)

    Luo, Fenqiang; Lin, Yaolin; Zheng, Liyan; Lin, Xiaomei; Chi, Yuwu

    2015-06-03

    Novel metal-organic frameworks (MOFs) based solid catalysts have been synthesized by encapsulating Hemin into the HKUST-1 MOF materials. These have been first applied in the chemiluminescence field with outstanding performance. The functionalized MOFs not only maintain an excellent catalytic activity inheriting from Hemin but also can be cyclically utilized as solid mimic peroxidases in the neutral condition. The synthesized Hemin@HKUST-1 composites have been used to develop practical sensors for H2O2 and glucose with wide response ranges and low detection limits. It was envisioned that catalyst-functionalized MOFs for chemiluminescence sensing would have promising applications in green, selective, and sensitive detection of target analytes in the future.

  16. A novel chemiluminescence method for determination of bisphenol Abased on the carbon dot-enhanced HCO3−–H2O2 system

    International Nuclear Information System (INIS)

    Amjadi, Mohammad; Manzoori, Jamshid L.; Hallaj, Tooba

    2015-01-01

    A simple and sensitive chemiluminescence (CL) method on the basis of carbon dot (C-dot) enhanced HCO 3 − –H 2 O 2 system, is designed for the determination of bisphenol A (BPA). The very weak CL of the HCO 3 − –H 2 O 2 system is enhanced by a factor of ∼100 in the presence of C-dots. Possible mechanisms that lead to the effect were elucidated by recording fluorescence and CL spectra and studying the effect of some radical scavengers. This enhancement is inhibited by BPA in the concentration range from 1.0 to 100 µg L −1 . This is exploited for its trace determination with a detection limit (3 s) of 0.3 µg L −1 . The established method was applied to the determination of BPA in baby bottle and water samples with satisfactory results. - Highlights: • The effect of carbon dots on HCO 3 − –H 2 O 2 chemiluminescence reaction is studied. • Carbon dots greatly enhance the CL signal of this reaction (∼100 fold). • The new CL system was applied to determination of bisphenol A in real samples

  17. Enhanced chemiluminescence for trazodone trace analysis based on acidic permanganate oxidation in concurrent presence of rhodamine 6G.

    Science.gov (United States)

    Fujimori, Keiichi; Sakata, Yuta; Moriuchi-Kawakami, Takayo; Shibutani, Yasuhiko

    2017-11-01

    A new sensitized chemiluminescence method by acidic permanganate oxidation was developed for the sensitive determination of trazodone. A fluorescent dye as used rhodamine 6G to increase a chemiluminescence intensity. Under optimum conditions, the liner range of the calibration curve was obtained for 1-5000 nmol/L. The limit of detection was calculated from 3σ of a blank was 0.23 nmol/L. The coexistent ions and substances had no interference with the chemiluminescence measurement. The chemiluminescence spectra were measured to elucidate a possible mechanism for the system. The present method was satisfactorily used in the determination of the drugs in pharmaceutical samples and animal serums. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Electrospun Polyhydroxybutyrate and Poly(L-lactide-co-ε-caprolactone Composites as Nanofibrous Scaffolds

    Directory of Open Access Journals (Sweden)

    Donraporn Daranarong

    2014-01-01

    Full Text Available Electrospinning can produce nanofibrous scaffolds that mimic the architecture of the extracellular matrix and support cell attachment for tissue engineering applications. In this study, fibrous membranes of polyhydroxybutyrate (PHB with various loadings of poly(L-lactide-co-ε-caprolactone (PLCL were successfully prepared by electrospinning. In comparison to PLCL scaffolds, PLCL blends with PHB exhibited more irregular fibre diameter distributions and higher average fibre diameters but there were no significant differences in pore size. PLCL/PHB scaffolds were more hydrophilic (<120° with significantly reduced tensile strength (ca. 1 MPa compared to PLCL scaffolds (150.9±2.8∘ and 5.8±0.5 MPa. Increasing PLCL loading in PHB/PLCL scaffolds significantly increased the extension at break, (4–6-fold. PLCL/PHB scaffolds supported greater adhesion and proliferation of olfactory ensheathing cells (OECs than those exhibiting asynchronous growth on culture plates. Mitochondrial activity of cells cultivated on the electrospun blended membranes was enhanced compared to those grown on PLCL and PHB scaffolds (212, 179, and 153%, resp.. Analysis showed that PLCL/PHB nanofibrous membranes promoted cell cycle progression and reduced the onset of necrosis. Thus, electrospun PLCL/PHB composites promoted adhesion and proliferation of OECs when compared to their individual PLCL and PHB components suggesting potential in the repair and engineering of nerve tissue.

  19. The effects of dynamic and three-dimensional environments on chondrogenic differentiation of bone marrow stromal cells

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Youngmee; Kim, Sang-Heon; Kim, Soo Hyun [Biomaterials Research Center, Korea Institute of Science and Technology, PO Box 131, Cheonryang, Seoul, 130-650 (Korea, Republic of); Kim, Young Ha, E-mail: soohkim@kist.re.k [Department of Materials Science and Engineering, Gwangju Institute of Science and Technology, 261 Cheomdan-gwagiro, Buk-gu, Gwangju 500-712 (Korea, Republic of)

    2009-10-15

    Articular cartilage is subjected to complex loading, which plays a major role in its growth, development and maintenance. Previously, we found that mechanical stimuli enhanced the development and function of engineered cartilage tissues in elastic mechano-active poly(lactide-co-caprolactone) (PLCL) scaffolds. In addition, it is well known that the three-dimensional spatial organization of cells and extracellular matrices in hydrogels is crucial to chondrogenesis. This study was conducted to enhance the chondrogenic differentiation of bone marrow stromal cells (BMSCs) in the hybrid scaffolds of fibrin gels and PLCL scaffolds in dynamic environments by compression. A highly elastic scaffold was fabricated from very elastic PLCL with 85% porosity and a 300-500{mu}m pore size using a gel-pressing method. A mixture of rabbit BMSCs and fibrin gels was then seeded onto the PLCL scaffolds and subjected to continuous compressive deformation of 5% strain at 0.1 Hz for 10 days in a chondrogenic medium containing 10 ng ml{sup -1} TGF-beta{sub 1}. The BMSCs-seeded scaffold constructs were then implanted subcutaneously into nude mice. As a control, the cell-PLCL scaffold constructs were cultured under dynamic conditions or the cell-PLCL/fibrin hybrid scaffold constructs and the cell-PLCL scaffold constructs were cultured under static conditions for 10 days in vitro. The results revealed that cells adhered onto the hybrid scaffolds of fibrin gels and PLCL scaffolds cultured under dynamic conditions. In addition, the accumulation of the extracellular matrix of cell-scaffold constructs, which was increased through mechanical stimulation, showed that chondrogenic differentiation was sustained and enhanced significantly in the stimulated hybrid scaffold constructs. Overall, the results of this study indicate that the proper periodic application of dynamic compression and the three-dimensional environments of the hybrid scaffolds composed of fibrin gels and elastic PLCL can encourage

  20. Chemiluminescent Determination of Oxamyl in Drinking Water and Tomato Using Online Postcolumn UV Irradiation in a Chromatographic System.

    Science.gov (United States)

    Murillo Pulgarín, José A; García Bermejo, Luisa F; Durán, Armando Carrasquero

    2018-03-07

    High-performance liquid chromatography (HPLC) was used to separate oxamyl from other pesticides in drinking water and tomato paste. The eluate emerging from the column tail was mixed with an alkaline solution of Co 2+ in EDTA and irradiated with UV light to induce photolysis of the carbamate in order to obtain free radicals and other reactive species that oxidize luminol and produce chemiluminescence (CL) as a result. The intensity of the CL signal was monitored in the form of chromatographic peaks. Under the optimum operating conditions for the HPLC-UV-CL system, the analyte concentration was linearly related to peak area. The limit of detection as determined in accordance with the IUPAC criterion was 0.17 mg L -1 . Oxamyl was successfully extracted with recoveries of 88.7-103.1% from spiked tomato paste by using a simple QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) sample preparation approach. Similar recoveries were obtained from drinking water samples spiked with oxamyl concentrations above the LOD. The proposed method is a simple, fast, accurate choice for quantifying this pesticide.

  1. Determination of aminoglycoside antibiotics using an on-chip microfluidic device with chemiluminescence detection

    International Nuclear Information System (INIS)

    Sierra-Rodero, M.; Fernandez-Romero, J.M.; Gomez-Hens, A.

    2012-01-01

    We describe an on-chip microflow injection (μFI) approach for the determination of aminoglycoside antibiotics using chemiluminescence (CL) detection. The method is based on the inhibition of the Cu(II)-catalyzed CL reaction of luminol and hydrogen peroxide by the aminoglycosides due to the formation of a complex between the antibiotic and Cu(II). The main features of the method include small sample volumes and a fast response. Syringe pumps were used to insert the sample and the reagents into the microfluidic device. CL was collected using a fiber optic bundle connected to a luminescence detector. All instrumental, hydrodynamic and chemical variables involved in the system were optimized using neomycin as the aminoglycoside model. Inhibition is proportional to the concentration of the antibiotics. The dynamic ranges of the calibration graphs obtained for neomycin, streptomycin and amikacin are 0.3-3.3, 0.9-13.7, and 0.8-8.5 μmol L -1 , and the detection limits are 0.09, 0.28 and 0.24 μmol L -1 , respectively. The precision of the methods, expressed as relative standard deviation, is in the range from 0.8 to 5.0 %. The method was successfully applied to the determination of neomycin in water samples, with recoveries ranging from 80 to 120 %. (author)

  2. Chemiluminescence immunoassay based on dual signal amplification strategy of Au/mesoporous silica and multienzyme functionalized mesoporous silica

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jiehua, E-mail: linjiehua@qust.edu.cn [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China); Zhao Yue; Wei Zhijing; Wang Wei [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China)

    2011-11-15

    Highlights: > The increased amount of monoclonal antibody in Au/SiO{sub 2} led to a wider linear range. > Due to the increased HRP tags in HRP-Ab{sub 2}/SiO{sub 2}, signal amplification achieved. > A simple dual amplification immunoassay achieved with flow injection analysis. - Abstract: A chemiluminescent dual signal amplification strategy for the determination of {alpha}-fetoprotein (AFP) was proposed based on a sandwich immunoassay format. Monoclonal antibody of AFP immobilized on the gold nanoparticles doped mesoporous SiO{sub 2} (Au/SiO{sub 2}) were prepared and used as a primary antibody. Horseradish peroxidase (HRP) and HRP-labeled secondary antibody (Ab{sub 2}) co-immobilized into the mesoporous SiO{sub 2} nanoparticles (HRP-Ab{sub 2}/SiO{sub 2}) were used as the labeled immunological probe. Due to the high ratio surface areas and pore volumes of the mesoporous SiO{sub 2}, not only the amount of AFP monoclonal antibody but also the amount of the modified HRP and Ab{sub 2} in HRP-Ab{sub 2}/SiO{sub 2} were largely increased. Thus the chemiluminescent signal was amplified by using the system of luminol and H{sub 2}O{sub 2} under the catalysis of HRP. Under the optimal conditions, two linear ranges for AFP were obtained from 0.01 to 0.5 ng mL{sup -1} and 0.5 to 100 ng mL{sup -1} with a detection limit of 0.005 ng mL{sup -1} (3{sigma}). The fabricated signal amplification strategy showed an excellent promise for sensitive detection of AFP and other tumor markers.

  3. Potential role of NADPH-oxidase in early steps of lead-induced oxidative burst in Vicia faba roots

    OpenAIRE

    Pourrut, Bertrand; Perchet, Geoffrey; Silvestre, Jérôme; Cecchi, Marie; Guiresse, Agnès Maritchù; Pinelli, Eric

    2008-01-01

    The mechanism of oxidative burst induced by lead in Vicia faba excised roots was investigated by luminol-dependent chemiluminescence. Results showed that lead triggered a rapid and dose-dependent increase in chemiluminescence production. In this study, specific inhibitors of putative reactive oxygen species (ROS) sources were used to determine the mechanism of lead-induced ROS generation. This generation was sensitive to dephenylene iodonium (DPI), quinacrine and imidazole, some inhibitors of ...

  4. Luminol-and lucigenin-amplified chemiluminescence with rat liver microsomes. Kinetics and influence of ascorbic acid, glutathione, dimethylsulfoxide, N-t-butyl-a-phenyl-nitrone, copper-ions and a copper complex, catalase, superoxide dismutase, hexobarbital and aniline.

    Science.gov (United States)

    Klinger, W; Karge, E; Kretzschmar, M; Rost, M; Schulze, H P; Dargel, R; Reinemann, C; Rein, H

    1996-07-01

    For the investigation of luminol (LM)-and lucigenin (LC)-amplified chemiluminescence (CL) in rat liver microsomes using both a liquid-scintillation counter (LKB/Wallac 1219 Rackbeta) and a Berthold luminometer (AutoLumat LB 953) optimal incubation mixtures and conditions and basic kinetics have been established. Whereas calibration curves for both LM- and LC-CL are performed with hydrogenperoxide (LC quantum yield is 6.25 fold higher as that of LM), distinct differences were revealed with microsomes, indicating that different reactive oxygen species (ROS) are determined: Both LM- and LC-CL follow the kinetics of enzymatic reactions in terms of dependence on protein and NADPH or NADH concentration, time course, temperature etc., but with differences. LM-CL does not work without addition of Fe2+, whereas LC-CL does. Both copper ions and copper bound in a complex abolish CL, LC-CL being much more sensitive. Isolated cytochrome P-450 (P450) and NADPH P450 reductase from liver of pheno-barbital treated rats alone proved to be inactive in LM-and LC-CL production, whereas te combination 1:1 without and with addition of lipid was highly active in both LM-and LC-CL. Ascorbic acid and glutathione as scavengers diminish both LM- and LC-CL in concentrations higher then 10(5). Dimethyl-sulfoxide (DMSO) was ineffective in LM-CL up to concentrations of 0.2 M, the very high concentration of 2 M diminished LM-CL only to 1/3. LC-CL was diminished starting at concentrations of 100 mM and at 2 M only 10% of maximum LC-CL was observed. The trap substance N-t-butyl-a-phenylnitrone (BNP) also diminished LC-CL more effectively than LM-CL. Clearcut differences were revealed by the addition of catalase and superoxide dismutase: both enzymes diminished LM-CL only, without any influence on LC-CL. Hexobarbital, a potent uncoupler of P450, enhances LM-CL fivefold, whereas LC-CL is barely influenced. Aniline (without uncoupling capability) decreased both LM-and LC-CL increasingly with increasing

  5. Chemiluminescence emission from irradiated polytetrafluoroethylene (PTFE)

    International Nuclear Information System (INIS)

    Zhong Xiaoguang; Sun Jiazhen; Yoshii, Fumio; Sasaki, Takashi; Makuuchi, Keizo

    2000-01-01

    PTFE is well known for its chemical and high temperature resistance and also for its high-energy radiation sensitivity. The present work deals with the radiation-induced emission of chemiluminescence from PTFE film, which is generally thought as a measure of radiation induced oxidation reaction in irradiated polymer. The observation that the much stronger chemiluminescence emission from PTFE than that from other polymeric system indicate the unusual high degree of radiation induced oxidation in PTFE. On the other hand the temperature and atmosphere effect during radiation on emission of chemiluminescence were also reported. (author)

  6. Multiple enhancement of luminol electrochemiluminescence using electrodes functionalized with titania nanotubes and platinum black: ultrasensitive determination of hydrogen peroxide, resveratrol, and dopamine

    International Nuclear Information System (INIS)

    Ming, Liang; Peng, Tingting; Tu, Yifeng

    2016-01-01

    We describe a substantial improvement of the electrochemiluminescence (ECL) of luminol which is widely used in flow injection analysis (FIA). It is based on synchronous dual sensitization of ECL by using titania nanotubes (TiNTs) and platinum black (PB). A piece of indium tin oxide (ITO) glass functionalized with TiNTs acts as the first working electrode, and a PB-modified platinum plate serves as the second one. By applying two constant potentials to the two electrodes, strong and consecutive ECL emission of luminol is obtained. The system works well in assays as shown for the successful quantitation of hydrogen peroxide (H 2 O 2 ), of the antioxidant resveratrol, and of the neutrotransmitter dopamine (DA) in spiked human serum samples. The detection limits for these three species (at a signal-to-noise ratio of 3) are as low as 66 pM (H 2 O 2 ), 22 nM (resveratrol), and 30 nM (DA). Recoveries in assays of DA in spiked serum range from 97.3 to 105.4 %. In our perception, the technique of dual sensitization represents a substantial improvement of the detection limits of ECL assays. (author)

  7. A low concentration of ethanol reduces the chemiluminescence of human granulocytes and monocytes but not the tumor necrosis factor alpha production by monocytes after endotoxin stimulation

    DEFF Research Database (Denmark)

    Parlesak, Alexandr; Diedrich, J. P.; Schäfer, Christian

    1998-01-01

    necrosis factor alpha (TNF-alpha) from Mphi. Further, the efficiency of ethanol to inactivate chemically generated ROS was tested. Significant stimulation of ROS release occurred at endotoxin concentrations of 1 ng/ml or higher in both PMNs and Mphi. Ethanol significantly suppressed the formation of ROS...... immunogens and to increase the susceptibility of alcohol abusers to infectious diseases. As endotoxemia is common in alcohol abusers, we investigated the effect of ethanol (21.7 mmol/liter) on the luminol-amplified chemiluminescence of PMNs and Mphi after endotoxin stimulation and the release of tumor...... identical (6 to 8 ng/ml) in both PMNs and Mphi, independent of the presence of ethanol. In contrast to ROS formation, ethanol had no effect on the amount of TNF-alpha produced by endotoxin-stimulated Mphi. Ethanol was shown to be unable to decrease the levels of chemically generated ROS under physiological...

  8. Regeneration of Achilles' tendon: the role of dynamic stimulation for enhanced cell proliferation and mechanical properties.

    Science.gov (United States)

    Lee, Jongman; Guarino, Vincenzo; Gloria, Antonio; Ambrosio, Luigi; Tae, Giyoong; Kim, Young Ha; Jung, Youngmee; Kim, Sang-Heon; Kim, Soo Hyun

    2010-01-01

    The tissue engineering of tendon was studied using highly elastic poly(L-lactide-co-epsilon-caprolactone) (PLCL) scaffolds and focusing on the effect of dynamic tensile stimulation. Tenocytes from rabbit Achilles tendon were seeded (1.0 x 10(6) cells/scaffold) onto porous PLCL scaffolds and cultured for periods of 2 weeks and 4 weeks. This was performed in a static system and also in a bioreactor equipped with tensile modulation which mimicked the environmental surroundings of tendons with respect to tensile extension. The degradation of the polymeric scaffolds during the culture was relatively slow. However, there was an indication that cells accelerated the degradation of PLCL scaffolds. The scaffold/cell adducts from the static culture exhibited inferior strength (at 2 weeks 350 kPa, 4 weeks 300 kPa) compared to the control without cells (at 2 weeks 460 kPa, 4 weeks 340 kPa), indicating that the cells contributed to the enhanced degradation. On the contrary, the corresponding values of the adducts from the dynamic culture (at 2 weeks 430 kPa, 4 weeks 370 kPa) were similar to, or higher than, those from the control. This could be explained by the increased quantity of cells and neo-tissues in the case of dynamic culture compensating for the loss in tensile strength. Compared with static and dynamic culture conditions, mechanical stimulation played a crucial role in the regeneration of tendon tissue. In the case of the dynamic culture system, cell proliferation was enhanced and secretion of collagen type I was increased, as evidenced by DNA assay and histological and immunofluorescence analysis. Thus, tendon regeneration, indicated by improved mechanical and biological properties, was demonstrated, confirming the effect of mechanical stimulation. It could be concluded that the dynamic tensile stimulation appeared to be an essential factor in tendon/ligament tissue engineering, and that elastic PLCL co-polymers could be very beneficial in this process.

  9. Investigation on a Sensitive Chemiluminescence System Based on Ni(IV Complex to Determine Two β2-Agonist Drugs in Urine and Swine Feed and Their Mechanism

    Directory of Open Access Journals (Sweden)

    Xiao Dong

    2018-04-01

    Full Text Available Veterinary drug residues, particularly traces of β2-agonists, can cause various kinds of harmful impact to the environment and public health. Here, a sensitive chemiluminescence (CL method incorporated with a flow injection analysis is developed for the determination of two β2-agonists [i.e., salbutamol (SAL and terbutaline (TEB]. The system is based on the CL reaction of Ni(IV complex with luminol in alkaline solutions, whereas SAL and TEB can significantly enhance CL intensities. Under optimum conditions, CL intensities are proportional to the SAL and TEB concentration in the range of 1.0 × 10−9 M to 5.0 × 10−7 M and 1.0 × 10−9 M to 1.0 × 10−7 M, respectively. The limits of detection (3σ are 1.0 × 10−11 M for TEB, and 1.3 × 10−11 for SAL respectively. Relative standard deviations (n = 11 are less than 2% for 5.0 × 10−8 M SAL and TEB. Possible reaction mechanisms for the CL system are suggested based on the CL system spectra, Ni(IV complex oxidation characteristics, and electron spin resonance (ESR techniques. The proposed method has been applied to the analysis of urine and swine feed samples with satisfactory results.

  10. Chemiluminescent Diagnostics of Free-Radical Processes in an Abiotic System and in Liver Cells in the Presence of Nanoparticles Based on Rare-Earth Elements nReVO4:Eu3+ (Re = Gd, Y, La) and CeO2

    Science.gov (United States)

    Averchenko, E. A.; Kavok, N. S.; Klochkov, V. K.; Malyukin, Yu. V.

    2014-11-01

    We have used luminol-dependent chemiluminescence with Fenton's reagent to study the effect of nanoparticles based on rare-earth elements of different sizes and shapes on free-radical processes in abiotic and biotic cell-free systems, and also in isolated cells in vitro. We have estimated the effects of rare-earth orthovanadate nanoparticles of spherical (GdYVO4:Eu3+, 1-2 nm), spindle-shaped (GdVO4:Eu3+, 25 ×8 nm), and rod-shaped (LaVO4:Eu3+, 57 × (6-8) nm) nanoparticles and spherical CeO2 nanoparticles (sizes 1-2 nm and 8-10 nm). We have shown that in contrast to the abiotic system, in which all types of nanoparticles exhibit antiradical activity, in the presence of biological material, extra-small spherical (1-2 nm) nanoparticles of both types exhibit pro-oxidant activity, and also enhance pro-oxidant induced oxidative stress (for the pro-oxidants hydrogen peroxide and tert-butyl hydroperoxide). The effect of rare-earth orthovanadate spindle and rod shaped nanoparticles in this system was neutral; a moderate antioxidant effect was exhibited by 8-10 nm CeO2 nanoparticles.

  11. Investigation of RuBPS-Ce(IV) chemiluminescence reaction and its application in determination of two diuretics

    Energy Technology Data Exchange (ETDEWEB)

    Xi Juan [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Ji Xinghu [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Zhang Shaohong [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Xiang Fan Vocational and Technical College, Xiangfan 441021 (China); Ai Xinping [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); He Zhike [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)]. E-mail: zhkhe@whu.edu.cn

    2005-06-13

    The chemiluminescence mechanism of tris-(4,7-diphenyl-1,10-phenanthrolinedisulfonic acid)ruthenium(II) (RuBPS)-Ce(IV) system and the effects of two diuretics, hydrochlorothiazide and furosemide, on its chemiluminescence intensity were investigated in detail. It was found that each of the two diuretics could enhance the chemiluminescence emission intensity of RuBPS-Ce(IV) system, based on which, they were sensitively detected by chemiluminescence analysis, respectively. Under the optimum experimental conditions, the linear range and detection limit of hydrochlorothiazide were 2.5 x 10{sup -3} to 6.0 x 10{sup -1} {mu}g ml{sup -1} and 1.0 x 10{sup -3} {mu}g ml{sup -1}, respectively; those of furosemide were 1.0 x 10{sup -2} to 4.0 {mu}g ml{sup -1} and 8.8 x 10{sup -3} {mu}g ml{sup -1}, respectively. The proposed method has been applied to analyze the pharmaceuticals with satisfied results.

  12. 40 CFR 1065.270 - Chemiluminescent detector.

    Science.gov (United States)

    2010-07-01

    ... Chemiluminescent detector. (a) Application. You may use a chemiluminescent detector (CLD) to measure NOX concentration in raw or diluted exhaust for batch or continuous sampling. We generally accept a CLD for NOX...) Component requirements. We recommend that you use a CLD that meets the specifications in Table 1 of § 1065...

  13. DNA imaging and quantification using chemi-luminescent probes; Imagerie et quantification d`ADN par chimiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Dorner, G; Redjdal, N; Laniece, P; Siebert, R; Tricoire, H; Valentin, L [Groupe I.P.B., Experimental Research Division, Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1999-11-01

    During this interdisciplinary study we have developed an ultra sensitive and reliable imaging system of DNA labelled by chemiluminescence. Based on a liquid nitrogen cooled CCD, the system achieves sensitivities down to 10 fg/mm{sup 2} labelled DNA over a surface area of 25 x 25 cm{sup 2} with a sub-millimeter resolution. Commercially available chemi-luminescent - and enhancer molecules are compared and their reaction conditions optimized for best signal-to-noise ratios. Double labelling was performed to verify quantification with radioactive probes. (authors) 1 fig.

  14. Rational design for enhancing inflammation-responsive in vivo chemiluminescence via nanophotonic energy relay to near-infrared AIE-active conjugated polymer.

    Science.gov (United States)

    Seo, Young Hun; Singh, Ajay; Cho, Hong-Jun; Kim, Youngsun; Heo, Jeongyun; Lim, Chang-Keun; Park, Soo Young; Jang, Woo-Dong; Kim, Sehoon

    2016-04-01

    H2O2-specific peroxalate chemiluminescence is recognized as a potential signal for sensitive in vivo imaging of inflammation but the effect of underlying peroxalate-emitter energetics on its efficiency has rarely been understood. Here we report a simple nanophotonic way of boosting near-infrared chemiluminescence with no need of complicated structural design and synthesis of an energetically favored emitter. The signal enhancement was attained from the construction of a nanoparticle imaging probe (∼26 nm in size) by dense nanointegration of multiple molecules possessing unique photonic features, i.e., i) a peroxalate as a chemical fuel generating electronic excitation energy in response to inflammatory H2O2, ii) a low-bandgap conjugated polymer as a bright near-infrared emitter showing aggregation-induced emission (AIE), and iii) an energy gap-bridging photonic molecule that relays the chemically generated excitation energy to the emitter for its efficient excitation. From static and kinetic spectroscopic studies, a green-emissive BODIPY dye has proven to be an efficient relay molecule to bridge the energy gap between the AIE polymer and the chemically generated excited intermediate of H2O2-reacted peroxalates. The energy-relayed nanointegration of AIE polymer and peroxalate in water showed a 50-times boosted sensing signal compared to their dissolved mixture in THF. Besides the high H2O2 detectability down to 10(-9) M, the boosted chemiluminescence presented a fairly high tissue penetration depth (>12 mm) in an ex vivo condition, which enabled deep imaging of inflammatory H2O2 in a hair-covered mouse model of peritonitis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Comparison of the performance of the borax buffer-based HRP-enhanced reagent and the 'Lumi-Phos 530' chemiluminescence systems in the detection of biotinylated DNA.

    Science.gov (United States)

    Cercek, B; Roby, K; Siaw, M

    1995-01-01

    A comparison of two chemiluminescence methods, the borax buffer-based HRP-enhanced reagent and Lumi-Phos 530, applied to the detection of a biotinylated 30-mer DNA slot blotted onto a nylon membrane, is presented. A streptavidin-HRP and streptavidin-ALP mediated detection system was used. The HRP-enhanced system is up to 15-fold greater with respect to the signal/background ratios than the Lumi-Phos 530 system at 0.5 microgram biotinylated DNA with at least a two-fold improvement in detection sensitivity for 0.5 ng biotinylated DNA.

  16. STIMULATION OF OXIDANT PRODUCTION IN ALVEOLAR MACROPHAGES BY POLLUTANT AND LATEX PARTICLES

    Science.gov (United States)

    Air pollutant dusts as well as chemically defined particles were examined for their activating effect on oxidant production (O2- and H2O2) in guinea pig alveolar macrophages (AM). Oxidant production was measured as chemiluminescence of albumin-bound luminol. All particles examine...

  17. The comparative performance of PMI estimation in skeletal remains by three methods (C-14, luminol test and OHI): analysis of 20 cases.

    Science.gov (United States)

    Cappella, Annalisa; Gibelli, Daniele; Muccino, Enrico; Scarpulla, Valentina; Cerutti, Elisa; Caruso, Valentina; Sguazza, Emanuela; Mazzarelli, Debora; Cattaneo, Cristina

    2015-01-27

    When estimating post-mortem interval (PMI) in forensic anthropology, the only method able to give an unambiguous result is the analysis of C-14, although the procedure is expensive. Other methods, such as luminol tests and histological analysis, can be performed as preliminary investigations and may allow the operators to gain a preliminary indication concerning PMI, but they lack scientific verification, although luminol testing has been somewhat more accredited in the past few years. Such methods in fact may provide some help as they are inexpensive and can give a fast response, especially in the phase of preliminary investigations. In this study, 20 court cases of human skeletonized remains were dated by the C-14 method. For two cases, results were chronologically set after the 1950s; for one case, the analysis was not possible technically. The remaining 17 cases showed an archaeological or historical collocation. The same bone samples were also screened with histological examination and with the luminol test. Results showed that only four cases gave a positivity to luminol and a high Oxford Histology Index (OHI) score at the same time: among these, two cases were dated as recent by the radiocarbon analysis. Thus, only two false-positive results were given by the combination of these methods and no false negatives. Thus, the combination of two qualitative methods (luminol test and microscopic analysis) may represent a promising solution to cases where many fragments need to be quickly tested.

  18. Measurement of hydroxyl radical production in ultrasonic aqueous solutions by a novel chemiluminescence method.

    Science.gov (United States)

    Hu, Yufei; Zhang, Zhujun; Yang, Chunyan

    2008-07-01

    Measurement methods for ultrasonic fields are important for reasons of safety. The investigation of an ultrasonic field can be performed by detecting the yield of hydroxyl radicals resulting from ultrasonic cavitations. In this paper, a novel method is introduced for detecting hydroxyl radicals by a chemiluminescence (CL) reaction of luminol-hydrogen peroxide (H2O2)-K5[Cu(HIO6)2](DPC). The yield of hydroxyl radicals is calculated directly by the relative CL intensity according to the corresponding concentration of H2O2. This proposed CL method makes it possible to perform an in-line and real-time assay of hydroxyl radicals in an ultrasonic aqueous solution. With flow injection (FI) technology, this novel CL reaction is sensitive enough to detect ultra trace amounts of H2O2 with a limit of detection (3sigma) of 4.1 x 10(-11) mol L(-1). The influences of ultrasonic output power and ultrasonic treatment time on the yield of hydroxyl radicals by an ultrasound generator were also studied. The results indicate that the amount of hydroxyl radicals increases with the increase of ultrasonic output power (< or = 15 W mL(-1)). There is a linear relationship between the time of ultrasonic treatment and the yield of H2O2. The ultrasonic field of an ultrasonic cleaning baths has been measured by calculating the yield of hydroxyl radicals.

  19. Dual-signal amplification strategy for ultrasensitive chemiluminescence detection of PDGF-BB in capillary electrophoresis.

    Science.gov (United States)

    Cao, Jun-Tao; Wang, Hui; Ren, Shu-Wei; Chen, Yong-Hong; Liu, Yan-Ming

    2015-12-01

    Many efforts have been made toward the achievement of high sensitivity in capillary electrophoresis coupled with chemiluminescence detection (CE-CL). This work describes a novel dual-signal amplification strategy for highly specific and ultrasensitive CL detection of human platelet-derived growth factor-BB (PDGF-BB) using both aptamer and horseradish peroxidase (HRP) modified gold nanoparticles (HRP-AuNPs-aptamer) as nanoprobes in CE. Both AuNPs and HRP in the nanoprobes could amplify the CL signals in the luminol-H2 O2 CL system, owing to the excellent catalytic behavior of AuNPs and HRP in the CL system. Meanwhile, the high affinity of aptamer modified on the AuNPs allows detection with high specificity. As proof-of-concept, the proposed method was employed to quantify the concentration of PDGF-BB from 0.50 to 250 fm with a detection limit of 0.21 fm. The applicability of the assay was further demonstrated in the analysis of PDGF-BB in human serum samples with acceptable accuracy and reliability. The result of this study exhibits distinct advantages, such as high sensitivity, good specificity, simplicity, and very small sample consumption. The good performances of the proposed strategy provide a powerful avenue for ultrasensitive detection of rare proteins in biological sample, showing great promise in biochemical analysis. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Strong enhancement of the chemiluminescence of the Cu(II)-H2O2 system on addition of carbon nitride quantum dots, and its application to the detection of H2O2 and glucose.

    Science.gov (United States)

    Hallaj, Tooba; Amjadi, Mohammad; Song, Zhenlun; Bagheri, Robabeh

    2017-12-19

    The authors report that carbon nitride quantum dots (CN QDs) exert a strong enhancing effect on the Cu(II)/H 2 O 2 chemiluminescent system. Chemiluminescence (CL) intensity is enhanced by CN QDs by a factor of ~75, while other carbon nanomaterials have a much weaker effect. The possible mechanism of the effect was evaluated by recording fluorescence and CL spectra and by examining the effect of various radical scavengers. Emitting species was found to be excited-state CN QDs that produce green CL peaking at 515 nm. The new CL system was applied to the sensitive detection of H 2 O 2 and glucose (via glucose oxidase-catalyzed formation of H 2 O 2 ) with detection limits (3σ) of 10 nM for H 2 O 2 and 100 nM for glucose. The probe was employed for glucose determination in human plasma samples with satisfactory results. Graphical abstract The effect of carbon nitride quantum dots (CN QDs) on Cu(II)-H 2 O 2 chemiluminescence reaction was studied and the new CL system was applied for sensitive detection of glucose based on the glucose oxidase (GOx)-catalyzed formation of H 2 O 2 .

  1. Capillary electrophoresis microchip coupled with on-line chemiluminescence detection

    International Nuclear Information System (INIS)

    Su Rongguo; Lin Jinming; Qu Feng; Chen Zhifeng; Gao Yunhua; Yamada, Masaaki

    2004-01-01

    In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis

  2. Advances in the use of acidic potassium permanganate as a chemiluminescence reagent: A review

    International Nuclear Information System (INIS)

    Adcock, Jacqui L.; Barnett, Neil W.; Barrow, Colin J.; Francis, Paul S.

    2014-01-01

    Graphical abstract: -- Highlights: •Analytical applications of acidic potassium permanganate chemiluminescence. •Discussion of emitting species and light-producing reaction pathways. •Influence of enhancers such as polyphosphates, formaldehyde and sulfite. •Clinical, forensic, food science, agricultural and environmental applications. -- Abstract: We review the analytical applications of acidic potassium permanganate chemiluminescence published since our previous comprehensive review in mid-2007 to early 2013. This includes a critical evaluation of evidence for the emitting species, the influence of additives such as polyphosphates, formaldehyde, sulfite, thiosulfate, lanthanide complexes and nanoparticles, the development of a generalized reaction mechanism, and the use of this chemistry in pharmaceutical, clinical, forensic, food science, agricultural and environmental applications

  3. Advances in the use of acidic potassium permanganate as a chemiluminescence reagent: A review

    Energy Technology Data Exchange (ETDEWEB)

    Adcock, Jacqui L.; Barnett, Neil W.; Barrow, Colin J.; Francis, Paul S., E-mail: psf@deakin.edu.au

    2014-01-07

    Graphical abstract: -- Highlights: •Analytical applications of acidic potassium permanganate chemiluminescence. •Discussion of emitting species and light-producing reaction pathways. •Influence of enhancers such as polyphosphates, formaldehyde and sulfite. •Clinical, forensic, food science, agricultural and environmental applications. -- Abstract: We review the analytical applications of acidic potassium permanganate chemiluminescence published since our previous comprehensive review in mid-2007 to early 2013. This includes a critical evaluation of evidence for the emitting species, the influence of additives such as polyphosphates, formaldehyde, sulfite, thiosulfate, lanthanide complexes and nanoparticles, the development of a generalized reaction mechanism, and the use of this chemistry in pharmaceutical, clinical, forensic, food science, agricultural and environmental applications.

  4. Detecção de manchas de sangue pelo luminol onde houve entintamento das paredes – estudo de caso

    Directory of Open Access Journals (Sweden)

    Geraldo Elias Miranda

    2016-04-01

    Full Text Available O luminol é um teste presuntivo para detecção de manchas de sangue, muito sensível, efetivo e seletivo. O objetivo deste trabalho é avaliar a eficácia do luminol na detecção de sangue após o entintamento das paredes em um local onde ocorreu um homicídio. Os peritos se dirigiram para a casa do suspeito e com o uso de uma espátula metálica retiraram parte do revestimento da parede do quarto e após nova aplicação do luminol observaram a mancha branco-azulada, intensa e de duração típica de sangue latente. Os fragmentos retirados da parede foram enviados para o laboratório de DNA que confirmou tratar-se de sangue da vítima. A aplicação dessa técnica no caso em questão encontrando manchas de sangue sob a pintura ajudou a perícia a traçar a dinâmica do evento, ficando mais clara a posição da vítima quando foi alvejada com tiros pelo seu agressor além de ligar aquele local à vítima. O luminol não é capaz de detectar sangue que está sob a tinta da parede. A deteção do sangue latente somente ocorre quando a camada de tinta é retirada.

  5. The Applications of Gold Nanoparticle-Initialed Chemiluminescence in Biomedical Detection

    Science.gov (United States)

    Liu, Zezhong; Zhao, Furong; Gao, Shandian; Shao, Junjun; Chang, Huiyun

    2016-10-01

    Chemiluminescence technique as a novel detection method has gained much attention in recent years owning to the merits of high sensitivity, wider linear ranges, and low background signal. Similarly, nanotechnology especially for gold nanoparticles has emerged as detection tools due to their unique physical and chemical properties. Recently, it has become increasingly popular to couple gold nanoparticles with chemiluminescence technique in biological agents' detection. In this review, we describe the superiority of both chemiluminescence and gold nanoparticles and conclude the different applications of gold nanoparticle-initialed chemiluminescence in biomedical detection.

  6. A rapid and simple chemiluminescence method for screening levels of inosine and hypoxanthine in non-traumatic chest pain patients.

    Science.gov (United States)

    Farthing, Don E; Sica, Domenic; Hindle, Michael; Edinboro, Les; Xi, Lei; Gehr, Todd W B; Gehr, Lynne; Farthing, Christine A; Larus, Terri L; Fakhry, Itaf; Karnes, H Thomas

    2011-01-01

    A rapid and simple chemiluminescence method was developed for detection of inosine and hypoxanthine in human plasma. The method utilized a microplate luminometer with direct injectors to automatically dispense reagents during sample analysis. Enzymatic conversions of inosine to hypoxanthine, followed by hypoxanthine to xanthine to uric acid, generated superoxide anion radicals as a useful metabolic by-product. The free radicals react with Pholasin(®) , a sensitive photoprotein used for chemiluminescence detection, to produce measurable blue-green light. The use of Pholasin(®) and a chemiluminescence signal enhancer, Adjuvant-K™, eliminated the need for plasma clean-up steps prior to analysis. The method used 20 μL of heparinized plasma, with complete analysis of total hypoxanthine levels (inosine is metabolized to hypoxanthine using purine nucleoside phosphorylase) in approximately 3.7 min. The rapid chemiluminescence method demonstrated the capability of differentiating total hypoxanthine levels between healthy individuals, and patients presenting with non-traumatic chest pain and potential acute cardiac ischemia. The results support the potential use of chemiluminescence methodology as a diagnostic tool to rapidly screen for elevated levels of inosine and hypoxanthine in human plasma, potential biomarkers of acute cardiac ischemia. Copyright © 2009 John Wiley & Sons, Ltd.

  7. Sensitive determination of 4-nitrophenol based on its enhancement of a peroxyoxalate chemiluminescence system containing graphene oxide quantum dots and fluorescein

    International Nuclear Information System (INIS)

    Chen, Donghua; Peng, Rulin; Zhou, Hong; Liu, Hui

    2016-01-01

    Graphene oxide quantum dots (GOQD) are capable of enhancing the green chemiluminescence (CL) of the system composed of bis (2,4,6-trichlorophenyl) oxalate, hydrogen peroxide and fluorescein (TCPO/H_2O_2/fluorescein). It was found that 4-nitrophenol (4-NP) causes a further enhancement of the system, and this was exploited to develop a CL detection scheme for 4-NP. The optimum reaction concentrations were established, and under these conditions the calibration plot is linear in the 1.0 to 300 pmol L"−"1 concentration range, with a 0.3 pmol L"−"1 detection limit (at 3σ).We assume that CL enhancement is due to energy transfer from GOQD to fluorescein which is promoted by the interaction of 4-NP with the GOQD. The method was applied to the determination of 4-NP in spiked tap water and river water and gave recoveries between 93.4 and 107.9 %, with relative standard deviations of <4.0 %. (author)

  8. Kinetics and selectivity of permanganate chemiluminescence: a study of hydroxyl and amino disubstituted benzene positional isomers.

    Science.gov (United States)

    Slezak, Teo; Smith, Zoe M; Adcock, Jacqui L; Hindson, Christopher M; Barnett, Neil W; Nesterenko, Pavel N; Francis, Paul S

    2011-11-30

    Examination of the chemiluminescence reactions of dihydroxybenzenes, aminophenols and phenylenediamines with acidic potassium permanganate has provided a new understanding of the relationships between analyte structure, reaction conditions, kinetics of the light-producing pathway and emission intensity, with broad implications for this widely utilised chemiluminescence detection system. Using a permanganate reagent prepared in a polyphosphate solution and adjusted to pH 2.5, large differences in the rate of reaction with different positional isomers were observed, with the meta-substituted forms reacting far slower and therefore exhibiting much lower chemiluminescence intensities in flow analysis systems. The preliminary partial reduction of permanganate to form significant concentrations of Mn(III) increased the rate of reaction with all analytes tested, resulting in comparable or (in the case of aminophenol and phenylenediamine) even greater emission intensities for the meta-isomers, demonstrating the opportunity to tune the selectivity of the reagent towards certain classes of compound or even specific positional isomers of the same compound. Using more acidic permanganate reagents, in which polyphosphates are not required, the discrepancy between the chemiluminescence intensities was still observed, but was less prominent due to the generally faster rates of reaction. The enhancement of these chemiluminescence reactions by on-line addition of formic acid or formaldehyde can in part also be attributed to the generation of significant pools of the key Mn(III) precursor to the emitting species. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Forensic Luminol Blood Test for Preventing Cross-contamination in Dentistry: An Evaluation of a Dental School Clinic.

    Science.gov (United States)

    Bortoluzzi, Marcelo Carlos; Cadore, Peterson; Gallon, Andrea; Imanishi, Soraia Almeida Watanabe

    2014-10-01

    More than 200 different diseases may be transmitted from exposure to blood in the dental setting. The aim of this study is to identify possible faults in the crosscontamination chain control in a dental school clinic searching for traces of blood in the clinical contact surfaces (CCS) through forensic luminol blood test. Traces of invisible blood where randomly searched in CCS of one dental school clinic. Forty eight surfaces areas in the CCS were tested and the presence of invisible and remnant blood was identified in 28 (58.3%) items. We suggest that the luminol method is suitable for identifying contamination with invisible blood traces and this method may be a useful tool to prevent cross-contamination in the dental care setting.

  10. Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital.

    Science.gov (United States)

    Tiwari, Aseem K; Pandey, Prashant K; Dara, Ravi C; Rawat, Ganesh S; Raina, Vimarsh; Bhargava, Richa

    2015-01-01

    Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. This study was designed to evaluate the performance of newly introduced VITROS(®) syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at -20°C, were used to evaluate the performance of VITROS(®) syphilis TPA assay based on enhanced chemiluminescence assay on VITROS(®) ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. VITROS(®) syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of endogenous interfering substances like free hemoglobin or fats. Performance of the VITROS(®) syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.

  11. Forensic Luminol Blood Test for Preventing Cross-contamination in Dentistry: An Evaluation of a Dental School Clinic

    Directory of Open Access Journals (Sweden)

    Marcelo Carlos Bortoluzzi

    2014-01-01

    Conclusions: We suggest that the luminol method is suitable for identifying contamination with invisible blood traces and this method may be a useful tool to prevent cross-contamination in the dental care setting.

  12. Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions

    Czech Academy of Sciences Publication Activity Database

    Sklenářová, H.; Voráčová, Ivona; Chocholouš, P.; Polášek, M.

    2017-01-01

    Roč. 184, APR (2017), s. 235-241 ISSN 0022-2313 Institutional support: RVO:68081715 Keywords : quantum dots * chemiluminescence * sequentialinjectionanalysis Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.686, year: 2016

  13. Fluorescence and chemiluminescence behavior of distyrylbenzene bearing two arms of dipicolylaminomethyl groups: Interactions with zinc ion and ATP

    Science.gov (United States)

    Motoyoshiya, Jiro; Wada, Jun-ya; Itoh, Keiko; Wakabayashi, Kazuaki; Maruyama, Takayuki; Ono, Kazuki; Fukasawa, Kota; Fujimoto, Tetsuya; Akaiwa, Yuji; Nonaka, Eiji

    2018-04-01

    The absorption and fluorescence spectral study of the distyrylbenzene bearing two arms of the dipicolylaminomethyl groups, the effective ligands for Zn2+, was studied in the presence of Zn2+ and ATP. Upon complexation of the distyrylbenzene with zinc ions in acetonitrile, enhancement of the fluorescence intensity was observed due to inhibition of intramolecular PET (photo-induced electron transfer) quenching, but no effect was found in aqueous media because the equilibrium laid to the free form of the ligands. In contrast, the addition of ATP disodium salt was effective to enhance the fluorescence intensity of the combination of the distyrylbenzne and Zn2+ in aqueous media. This assembly was applied to the peroxyoxalate chemiluminescence system and a significant increase in the intensity was observed, which provides a potential detection for ATP by chemiluminescence.

  14. Bio- and chemiluminescence imaging in analytical chemistry

    International Nuclear Information System (INIS)

    Roda, Aldo; Guardigli, Massimo; Pasini, Patrizia; Mirasoli, Mara; Michelini, Elisa; Musiani, Monica

    2005-01-01

    Bio- and chemiluminescence imaging techniques combine the high sensitivity of bio- and chemiluminescence detection with the ability of current light imaging devices to localize and quantify light emission down to the single-photon level. These techniques have been successfully exploited for the development of sensitive analytical methods relying on the evaluation of the spatial distribution of the light emitted from a target sample. In this paper, we report on recent applications of bio- and chemiluminescence imaging for in vitro and in vivo assays, including: quantitative assays performed in various analytical formats, such as microtiter plates, microarrays and miniaturized analytical devices, used in the pharmaceutical, clinical, diagnostic and environmental fields; luminescence imaging microscopy based on enzymatic, immunohistochemical and in situ hybridization reactions for the localization of metabolites, enzymes, antigens and gene sequences in cells and tissues; whole-body luminescence imaging in live animals for evaluating biological and pathological processes and for pharmacological studies

  15. Differential stimulation of luminol-enhanced chemiluminescence (CL) and arachidonic acid metabolism in rat peritoneal neutrophils

    Energy Technology Data Exchange (ETDEWEB)

    Sturm, R.J.; Adams, L.M.; Cullinan, C.A.; Berkenkopf, J.W.; Weichman, B.M.

    1986-03-05

    Phorbol 12-myristate, 13-acetate (PMA) induced the production of radical oxygen species (ROS) from rat peritoneal neutrophils as assessed by CL. ROS generation occurred in a time- (maximum at 13.5 min) and dose- (concentration range of 1.7-498 nM) related fashion. However, 166 nM PMA did not induce either cyclooxygenase (CO) or lipoxygenase (LPO) product formation by 20 min post-stimulation. Conversely, A23187, at concentrations between 0.1 and 10 ..mu..M, stimulated both pathways of arachidonic acid metabolism, but had little or no effect upon ROS production. When suboptimal concentrations of PMA (5.5 nM) and A23187 (0.1-1 ..mu..M) were coincubated with the neutrophils, a synergistic ROS response was elicited. However, arachidonic acid metabolism in the presence of PMA was unchanged relative to A12187 alone. Nordihydroguaiaretic acid (NDGA) inhibited both PMA-induced CL (IC/sub 50/ = 0.9 ..mu..M) and A23187-induced arachidonic acid metabolism (IC/sub 50/ = 1.7 ..mu..M and 6.0 ..mu..M for LPO and CO, respectively). The mixed LPO-CO inhibitor, BW755C, behaved in a qualitatively similar manner to NDGA, whereas the CO inhibitors, indomethacin, piroxicam and naproxen had no inhibitory effect on ROS generation at concentrations as high as 100 ..mu..M. These results suggest that NDGA and BW755C may inhibit CL and arachidonic acid metabolism by distinct mechanisms in rat neutrophils.

  16. Evaluation of enhanced chemiluminescence enzymeimmunoassay(CLEIA) in the determination of thyrotropin(TSH) using amerlite system

    International Nuclear Information System (INIS)

    Lee, Chae H.; Kim, Hwan k.; Kim, Jin Gyu

    1989-01-01

    The determination of thyrotropin(TSH) is useful in diagnosis of thyroid diseases. And the widely-used method for the determination of thyrotropin is radioimmunoassay so far because of its sensitivity. But its radiohazard and relatively short half-life of isotopes necessitates alternative methods. So many novel non-isotopic immunoassays are developed and now replacing RIA in routine laboratory measurements. We evaluated the enhanced chemiluminescence enzymeimmunoassay (Amerlite, Amersham International plc., U.K.) for the determination of serum TSH. We got good precision result with control sera. Within-assay and between-assay precision revealed less than 10%(C.V.) respectively. And comparision with CLEIA to RIA showed good correlation (y=0.648x + 0.170, r=0.978, y=value of CLEIA, x=values of RIA, n=35). We also got good correlation between singletons and duplicates result from 35 patients sera (y=0.967x + 0.0281, r=0.997, y=values of singletons, x=values of duplicates). We concluded that CLEIA is vary reliable and economic method for the determination of human TSH substitutive for RIA because of its precision and unnecessary duplicate measurements. (Author)

  17. Fe(III)-TAML activator: a potent peroxidase mimic for chemiluminescent determination of hydrogen peroxide.

    Science.gov (United States)

    Vdovenko, Marina M; Demiyanova, Alexandra S; Kopylov, Kirill E; Sakharov, Ivan Yu

    2014-07-01

    Efforts to replace native peroxidase with its low molecular weight alternatives have stimulated a search for peroxidase mimetics. Herein we describe the oxidation of luminol with hydrogen peroxide catalyzed by commercially available Fe(III)-TAML activator 1a, which was shown to be a more active catalyst than hemin. At Fe(III)-TAML activator 1a use in chemiluminescent assay for H2O2 determination the detection limit value (3σ) of 5×10(-8)M was similar to the detection limit obtained with horseradish peroxidase (1×10(-7)M) and significantly lower than that obtained in the presence of hemin (6×10(-7)M). The linear ranges (R(2)=0.98) of the assay were 6×10(-8)-1×10(-6)M and 6×10(-7)-1×10(-6)M H2O2 for Fe(III)-TAML 1a and hemin, respectively. The CV values for Fe(III)-TAML 1a-based assay measured within the working range varied from 1.0% to 3.7% (n=4), whereas in the case of hemin -5.0% to 9.7% (n=4). Moreover, the sensitivity of Fe(III)-TAML 1a-based method was 56 and 5 times higher than that of hemin- and HRP-based methods, respectively. The obtained results open good perspectives to apply Fe(III)-TAML activator 1a in CL analytical methods instead of hemin, a traditionally used peroxidase mimetic. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sklenářová, Hana, E-mail: sklenarova@faf.cuni.cz [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic); Voráčová, Ivona [Institute of Analytical Chemistry of the CAS, v. v. i., Brno (Czech Republic); Chocholouš, Petr; Polášek, Miroslav [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic)

    2017-04-15

    The effect of 0.01–100 µmol L{sup −1} Quantum Dots (QDs) with different emission wavelengths (520–640 nm) and different surface modifications (mercaptopropionic, mercaptoundecanoic, thioglycolic acids and mercaptoethylamine) on permanganate-induced and luminol–hydrogen peroxide chemiluminescence (CL) was studied in detail by a sequential injection technique using a spiral detection flow cell and a flow-batch detection cell operated in flow and stop-flow modes. In permanganate CL system no significant enhancement of the CL signal was observed while for the luminol–hydrogen peroxide CL substantial increase (>100% and >90% with the spiral detection cell in flow and stop-flow modes, respectively) was attained for CdTe QDs. Enhancement exceeding 120% was observed for QDs with emissions at 520, 575 and 603 nm (sizes of 2.8 nm, 3.3 nm and 3.6 nm) using the flow-batch detection cell in the stop-flow mode. Pronounced effect was noted for surface modifications while mercaptoethylamine was the most efficient in CL enhancement compared to mercaptopropionic acid the most commonly applied coating. Significant difference between results obtained in flow and flow-batch conditions based on the entire kinetics of the extremely fast CL reaction was discussed. The increase of the CL signal was always accompanied by reduced lifetime of the CL emission thus application of QDs in flow techniques should be always coupled with the study of the CL lifetime.

  19. Potentiation of the generation of reactive oxidants by human phagocytes during exposure to benoxaprofen and ultraviolet radiation in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.; Eftychis, H.A.

    1986-09-01

    The effects of ultraviolet (UV) radiation on the spontaneous membrane-associated oxidative metabolism of human polymorphonuclear leukocytes (PMNL) and mononuclear leukocytes (MNL), co-incubated in the presence and absence of the non-steroidal, anti-inflammatory drug (NSAID) benoxaprofen at various concentrations, were investigated in vitro. Assays of superoxide generation and luminol-enhanced chemiluminescence (CL) were used to detect the production of reactive oxidants by PMNL and MNL. The pro-oxidative effects of benoxaprofen and UV radiation alone and in combination are dependent on intact phagocyte membrane-associated oxidative metabolism. It is postulated that the pro-oxidative interactions which occur between human phagocytes, benoxaprofen and ultraviolet radiation cause the dermatological side-effects of benoxaprofen.

  20. Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital

    Directory of Open Access Journals (Sweden)

    Aseem K Tiwari

    2015-01-01

    Full Text Available Context: Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. Aims: This study was designed to evaluate the performance of newly introduced VITROS ® syphilis Treponema pallidum agglutination (TPA assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. Materials and Methods: A total of 108 random blood units collected from the donors (both voluntary and replacement donors and 28 known syphilis sero-reactive samples stored at −20°C, were used to evaluate the performance of VITROS ® syphilis TPA assay based on enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. Results: VITROS ® syphilis TPA showed 100% sensitivity and specificity with precision (20 days study of <10% co-efficient of variation. There was no cross-reactivity with other viral and auto-immune antibodies. No interference was observed from endogenous interfering substances like free hemoglobin or fats. Conclusions: Performance of the VITROS ® syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.

  1. High-performance liquid chromatographic assay of parabens in wash-off cosmetic products and foods using chemiluminescence detection

    International Nuclear Information System (INIS)

    Zhang Qunlin; Lian Mei; Liu Lijuan; Cui Hua

    2005-01-01

    A new method for the simultaneous determination of parabens including methylparaben, ethylparaben, propylparaben, and butylparaben by high-performance liquid chromatography (HPLC) coupled with chemiluminescence detection was developed. The procedure was based on the chemiluminescent enhancement by parabens of the cerium(IV)-rhodamine 6G system in the strong sulfuric acid medium. The good separation of parabens was carried out with an isocratic elution using a mixture of methanol and water (60:40, v/v) within 8.5 min. Under the optimized conditions, a linear working range extends three orders of magnitude with the relative standard deviations of intra- and inter-day precision below 4.5%, and the detection limits were 1.9 x 10 -9 , 2.7 x 10 -9 , 3.9 x 10 -9 , and 5.3 x 10 -9 g ml -1 for methylparaben, ethylparaben, propylparaben, and butylparaben, respectively. The chemiluminescence reaction was well compatible with the mobile phase of high-performance liquid chromatography. The proposed method has been successfully applied to the assay of parabens in wash-off cosmetic products and foods with the minimal sample preparation

  2. Estimating the yin-yang nature of Western herbs: a potential tool based on antioxidation-oxidation theory.

    Science.gov (United States)

    Gilca, Marilena; Gaman, Laura; Lixandru, Daniela; Stoian, Irina

    2014-01-01

    One of the biggest obstacles to progress in traditional Chinese medicine (TCM) development in Western countries is the difficulty of applying the traditional concepts to the Western medicinal plants, which are not traditionally described in ancient literature. During recent years, new advances in the field of understanding Yin/Yang aspects from a modern bioscientific point of view have led to the conclusion that antioxidationoxidation concepts might mirror a Yin-Yang relationship. This study was intended to integrate the Yin-Yang theory of the traditional Chinese medicine with modern antioxidation-oxidation theory, and to propose a biochemical tool based on redox parameters (e.g. antioxidant capacity, chemiluminescence-CL signal inducing capacity), usable for the classification of Western medicinal plants from Yin/Yang perspective. Trolox equivalent antioxidant capacity (TEAC) of six vegetal aqueous extracts (Symphitum officinalae (radix)-SYM, Inula helenium (radix)-INU, Calendula officinalis (flores)-CAL, Angelica arhanghelica (folium)ANG(F), Angelica arhanghelica (radix)-ANG(R), Ecbalium Elaterium (fruits)-ECB) and luminol-enhanced chemiluminescence of PMNL on addition of these vegetal extracts were measured. Percentages from the maximal or minimal values obtained were calculated for each extract (TEAC%, PMNL stimulation%, PMNL inhibition%, relative speed of action% (RSA%%)), specific Yin-Yang significance was assigned to each relative parameter. In the end, an integration of all the relative values was done, in order to find a global "Yin" or a "Yang" trait of each vegetal extract. TEAC decreased in the following order: SYM > INU > CAL >ANG(F) > ANG(R > ECB. Three vegetal extracts (SYM > INU > ECB) decreased the luminol-enhanced chemiluminescence of PMNL, two (ANG(R) > ANG(F)) increased it, while one (CAL) had a dual effect. After the integration of the percentages, CAL was found to have a global "Yang" trait, while the rest of the plants had a global "Yin

  3. Ultrasensitive chemiluminescence of tetracyclines in the presence of MCLA

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Wangsheng; Zhu, Chenyao [School of Public Health, Nanchang University, Nanchang 330006 (China); Liu, Hongcheng [Institute of Quality Standard and Testing Technology, Yunnan Academy of Agriculture Science, 650223 Kunming (China); Liu, Jing; Cai, Hongping [School of Public Health, Nanchang University, Nanchang 330006 (China); Cheng, Xianglei, E-mail: chengxlsd@163.com [School of Public Health, Nanchang University, Nanchang 330006 (China); Wei, Lijun, E-mail: weilj7681@163.com [School of Public Health, Nanchang University, Nanchang 330006 (China)

    2017-06-15

    In this article, five tetracyclines (TCs) showed ultrasensitive chemiluminescence (CL) based on the novel CL system of methoxylated Cypridina luciferin analogues (MCLA) and Ce(IV). It was found that the CL intensity of MCLA-Ce(IV) system was enhanced 30 times by adding 10 pmol chlortetracycline. Mechanisms of MCLA-Ce(IV)-TCs were investigated by CL spectra, radical scavengers and UV spectra. The results indicated that singlet oxygen, resulting from the reaction between Ce(IV) and TCs, was involved in the enhancement of CL phenomenon. This CL system coupling with flow injection analysis was developed for the determination of five common TCs. Linear ranged from 100 fmol to 20 pmol (r>0.999) with limit of detection of 20 to 50 fmol (S/N=3). The sensitivity of the present method is comparable to that of UPLC-MS/MS detection for TCs.

  4. Chemiluminescence behavior based on oxidation reaction of rhodamine B with cerium(IV) in sulfuric acid medium

    International Nuclear Information System (INIS)

    Ma Yongjun; Jin Xiaoyong; Zhou Min; Zhang Ziyu; Teng Xiulan; Chen Hui

    2003-01-01

    The chemiluminescence (CL) of the rhodamine B (RhB)-cerium(IV) system was investigated by flow-injection. Rhodamine B was suggested to be a suitable chemiluminescent reagent in acidic conditions. When the concentration of rhodamine B was 100 mg l -1 and cerium sulfate was 1.6 mmol l -1 in sulfuric acid, the chemiluminescent intensity was found to be highest by using 0.3 mol l -1 sulfuric acid as a carrier solution. The particular chemiluminescent system could tolerate such distinct acidic environments that it was utilized for detecting many compounds that are stable in acidic solutions. Furthermore, by virtue of IR, UV-Vis and luminescence spectroscopic measurements, the chemiluminescent behavior of rhodamine B was studied and a possible mechanism for this chemiluminescent reaction was proposed. The emitter was affirmed to be a radical species due to one of the oxidation products of RhB; the chemiluminescent emissive wavelength was about 425 nm

  5. Chemiluminescence behavior based on oxidation reaction of rhodamine B with cerium(IV) in sulfuric acid medium

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yongjun; Jin Xiaoyong; Zhou Min; Zhang Ziyu; Teng Xiulan; Chen Hui

    2003-08-18

    The chemiluminescence (CL) of the rhodamine B (RhB)-cerium(IV) system was investigated by flow-injection. Rhodamine B was suggested to be a suitable chemiluminescent reagent in acidic conditions. When the concentration of rhodamine B was 100 mg l{sup -1} and cerium sulfate was 1.6 mmol l{sup -1} in sulfuric acid, the chemiluminescent intensity was found to be highest by using 0.3 mol l{sup -1} sulfuric acid as a carrier solution. The particular chemiluminescent system could tolerate such distinct acidic environments that it was utilized for detecting many compounds that are stable in acidic solutions. Furthermore, by virtue of IR, UV-Vis and luminescence spectroscopic measurements, the chemiluminescent behavior of rhodamine B was studied and a possible mechanism for this chemiluminescent reaction was proposed. The emitter was affirmed to be a radical species due to one of the oxidation products of RhB; the chemiluminescent emissive wavelength was about 425 nm.

  6. Chemiluminescence of creatinine/H2O2/Co(2+) and its application for selective creatinine detection.

    Science.gov (United States)

    Hanif, Saima; John, Peter; Gao, Wenyue; Saqib, Muhammad; Qi, Liming; Xu, Guobao

    2016-01-15

    Creatinine is an important biomarker in clinical diagnosis and biomonitoring programs as well as urinary metabolomic/metabonomics research. Current methods are either nonselective, time consuming or require heavy and expensive instruments. In this study, chemiluminescence of creatinine with hydrogen peroxide has been reported for the first time, and its chemiluminescence is remarkably enhanced in the presence of cobalt ions. By utilizing these phenomena, we have developed a sensitive and selective chemiluminescence method for creatinine determination by coupling with flow injection analysis. The calibration curve is linear in the range of 1×10(-7)-3×10(-5)mol/L with a limit of detection (S/N=3) of 7.2×10(-8)mol/L, which is adequate for detecting creatinine in the clinically accepted range. The relative standard deviation for seven measurements of 3×10(-5)mol/L creatinine is 1.2%. The chemiluminescence method was then utilized to detect creatinine in human urine samples after simple dilution with water. It takes less than 1min each measurement and the recoveries for spiked urine samples were 100-103%. The interference study demonstrates that some common species in urine, such as amino acids, ascorbic acid and creatine, have negligible effects on creatinine detection. The present method does not use expensive instruments, enzymes and separation technique. This method has the advantages of sensitivity, selectivity, simplicity, rapidity, and low cost. It holds great promise for basic or comprehensive metabolic panel, drug screening, anti-dopping, and urinary metabolomic/metabonomics research. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. FEATURES OF CHEMILUMINESCENT ACTIVITY OF NEUTROPHILIC GRANULOCYTES IN PATIENTS WITH CHRONIC GASTRITIS, CHRONIC ATROPHIC GASTRITIS AND GASTRIC CANCER

    Directory of Open Access Journals (Sweden)

    O. V. Smirnova

    2017-01-01

    Full Text Available Chronic gastritis is the most common disease of gastro-intestinal tract. Precancerous potential is among most important epidemiological features of chronic gastritis. Immune system plays a distinct role in transformation from precancerous state to malignancy. In this context, the aim of our work was a study of spontaneous and induced chemiluminescence activity of neutrophilic granulocytes in patients with chronic superficial gastritis, chronic atrophic gastritis and gastric cancer. The work presents results of comprehensive laboratory examination of patients with chronic gastritis (CG (a total of 85 persons. 25 patients with chronic atrophic gastritis (CAG, and 50 patients with gastric cancer (GC at the age of 19 to 70 years were enrolled. Control group included 115 healthy donors without gastrointestinal complaints at the age of 19 to 67 years. The study was performed with venous blood samples taken from cubital vein into Vacutainer tubes with sodium heparin (5 U/mL prior to starting any pathogenic treatment. Evaluation of spontaneous and induced chemiluminescence was performed for 90 minutes at a 36-channel “CL 3606” chemiluminescence analyzer (Russia. In our study, patients with gastric cancer showed clear unidirectional changes in chemiluminescent activity of neutrophilic granulocytes (NG. When measuring spontaneous and induced NG chemiluminescence, we diagnosed a decreased phagocytic activity characterized by prolonged time-to-peak and area under the curve for spontaneous and induced CL, thus presuming longer activation time required in cases of reduced phagocytic function. The NG activity in patients with chronic gastritis is not impaired, but, similar changes of time-to-peak and area under were detected. Chemiluminescent activity of NG is increased in the group of CAG patients, and, considering similar changes in activation time and area under the curve, NG also produce greater amount of reactive oxygen species. Thus, for all H

  8. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Bü chel, Gabriel E.; Carney, Brandon; Shaffer, Travis M.; Tang, Jun; Austin, Christine; Arora, Manish; Zeglis, Brian M.; Grimm, Jan; Eppinger, Jö rg; Reiner, Thomas

    2016-01-01

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Near-Infrared Intraoperative Chemiluminescence Imaging

    KAUST Repository

    Büchel, Gabriel E.

    2016-08-03

    Intraoperative imaging technologies recently entered the operating room, and their implementation is revolutionizing how physicians plan, monitor, and perform surgical interventions. In this work, we present a novel surgical imaging reporter system: intraoperative chemiluminescence imaging (ICI). To this end, we have leveraged the ability of a chemiluminescent metal complex to generate near-infrared light upon exposure to an aqueous solution of Ce4+ in the presence of reducing tissue or blood components. An optical camera spatially resolves the resulting photon flux. We describe the construction and application of a prototype imaging setup, which achieves a detection limit as low as 6.9pmolcm-2 of the transition-metal-based ICI agent. As a proof of concept, we use ICI for the invivo detection of our transition metal tracer following both systemic and subdermal injections. The very high signal-to-noise ratios make ICI an interesting candidate for the development of new intraoperative imaging technologies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. A Novel Technique for Generating and Observing Chemiluminescence in a Biological Setting

    KAUST Repository

    Bü chel, Gabriel E.; Carney, Brandon; Tang, Jun; Zeglis, Brian M.; Eppinger, Jö rg; Reiner, Thomas

    2017-01-01

    not yet explored for intraoperative imaging: chemiluminescent imaging. This method employs a ruthenium-based chemiluminescent reporter along with a custom-built nebulizing system to produce ex vivo or in vivo images with high signal-to-noise ratios

  11. Ultra-sensitive chemiluminescent detection of Staphylococcus aureus based on competitive binding of Staphylococcus protein A-modified magnetic beads to immunoglobulin G

    International Nuclear Information System (INIS)

    Xiong, Jie; Wang, Wenwen; Zhou, Yali; Kong, Weijun; Wang, Zhenxing; Fu, Zhifeng

    2016-01-01

    Staphylococcus protein A (SPA) is a surface protein only expressed naturally in the cell walls of Staphylococcus aureus (S. aureus) and binds specifically to the Fc region of immunoglobulin G (IgG). This fact can be utilized for the detection of S. aureus. Specifically, SPA-modified magnetic beads, compete with S. aureus pathogens for binding to rabbit IgG that previously was labeled with horseradish peroxidase (HRP). The beads were then magnetically separated, and chemiluminescence (CL) was generated by adding the reagents luminol and H_2O_2. Under optimal conditions, the intensity of CL decreases with increasing concentration of S. aureus over a very wide linear range (10 to 1.0 × 10"9 cfu·mL"−"1), with a limit of detection of 6.0 cfu·mL"−"1 at an S/N ratio of 3. The assay (including binding reaction, magnetic separation, washing of beads and detection) is completed within 50 min which is faster than many reported methods. It can well distinguish S. aureus from other Gram-positive and Gram-negative bacteria. The magnetic beads have the beneficial effect of eliminating undesired matrix effects and of concentrating the sample. The method was applied to the analysis of urine, apple juice and glucose injection samples spiked with S. aureus, and recoveries ranged from 85 to 107 %. (author)

  12. 3D-printed and CNC milled flow-cells for chemiluminescence detection.

    Science.gov (United States)

    Spilstead, Kara B; Learey, Jessica J; Doeven, Egan H; Barbante, Gregory J; Mohr, Stephan; Barnett, Neil W; Terry, Jessica M; Hall, Robynne M; Francis, Paul S

    2014-08-01

    Herein we explore modern fabrication techniques for the development of chemiluminescence detection flow-cells with features not attainable using the traditional coiled tubing approach. This includes the first 3D-printed chemiluminescence flow-cells, and a milled flow-cell designed to split the analyte stream into two separate detection zones within the same polymer chip. The flow-cells are compared to conventional detection systems using flow injection analysis (FIA) and high performance liquid chromatography (HPLC), with the fast chemiluminescence reactions of an acidic potassium permanganate reagent with morphine and a series of adrenergic phenolic amines. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Chemiluminescence. Principles and applications in biology and medicine

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, A K

    1988-01-01

    Chemiluminescence, the emission of light caused by a chemical reaction, is a phenomenon used for many applications and of wide biological importance. It occurs in bacteria and insects (including glow-worms and fireflies), in many of the animals in the deep sea and even in human cells. The last 25 years have witnessed fast progress in the elucidation of the reactions and mechanisms underlying bioluminescence and light production by synthetic systems. Together with the development of highly sensitive light detectors, this has made available new biomedical methods and has given rise to new concepts concerning the biology and pathology of the cell. The book describes the occurrence, chemistry and measurement of chemiluminescence. It deals with the biological function and evolutionary significance, and looks at the many biomedical applications. The author describes the uses of chemiluminescence to measure enzymes, substrates and metabolites, to detect the changes of calcium concentration in living cells, to determine oxygen radicals or to replace the radioactive labels in immunoassays. Future applications in research and clinical laboratories are also discussed.

  14. Biological water quality monitoring using chemiluminescent and bioluminescent techniques

    Science.gov (United States)

    Thomas, R. R.

    1978-01-01

    Automated chemiluminescence and bioluminescence sensors were developed for the continuous monitoring of microbial levels in water supplies. The optimal chemical procedures were determined for the chemiluminescence system to achieve maximum sensitivity. By using hydrogen peroxide, reaction rate differentiation, ethylene diamine tetraacetic acid (EDTA), and carbon monoxide pretreatments, factors which cause interference were eliminated and specificity of the reaction for living and dead bacteria was greatly increased. By employing existing technology with some modifications, a sensitive and specific bioluminescent system was developed.

  15. Flow-injection chemiluminescence assay for ultra-trace determination of DNA using rhodamine B-Ce(IV)-DNA ternary system in sulfuric acid media

    International Nuclear Information System (INIS)

    Ma Yongjun; Zhou Min; Jin Xiaoyong; Zhang Ziyu; Teng Xiulan; Chen Hui

    2004-01-01

    A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0x10 -8 to 0.1 μg ml -1 for herring sperm DNA and 2.0x10 -6 to 0.2 μg ml -1 for calf thymus DNA with 3σ detection limits of 8.3x10 -9 μg ml -1 for herring sperm DNA and 3.5x10 -7 μg ml -1 for calf thymus DNA, respectively. The relative standard deviation for 1.0x10 -4 μg ml -1 herring sperm DNA was 0.99% and 2.0x10 -3 μg ml -1 for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper

  16. Flow-injection chemiluminescence assay for ultra-trace determination of DNA using rhodamine B-Ce(IV)-DNA ternary system in sulfuric acid media

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yongjun; Zhou Min; Jin Xiaoyong; Zhang Ziyu; Teng Xiulan; Chen Hui

    2004-01-09

    A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0x10{sup -8} to 0.1 {mu}g ml{sup -1} for herring sperm DNA and 2.0x10{sup -6} to 0.2 {mu}g ml{sup -1} for calf thymus DNA with 3{sigma} detection limits of 8.3x10{sup -9} {mu}g ml{sup -1} for herring sperm DNA and 3.5x10{sup -7} {mu}g ml{sup -1} for calf thymus DNA, respectively. The relative standard deviation for 1.0x10{sup -4} {mu}g ml{sup -1} herring sperm DNA was 0.99% and 2.0x10{sup -3} {mu}g ml{sup -1} for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper.

  17. Chemiluminescence determination of ultramicro DNA with a flow-injection method

    International Nuclear Information System (INIS)

    Chen Hui; Zhou Min; Jin Xiaoyong; Song Yumin; Zhang Ziyu; Ma Yongjun

    2002-01-01

    A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6x10 -5 to 0.26 μg ml -1 for calf thymus DNA and 5.0x10 -8 to 5.0x10 -5 μg ml -1 for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3σ) are 6.5x10 -6 μg ml -1 for calf thymus DNA and 4.3x10 -8 μg ml -1 for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed

  18. Determination of hyperin in seed of Cuscuta chinensis Lam. by enhanced chemiluminescence of CdTe quantum dots on calcein/K3Fe(CN)6 system.

    Science.gov (United States)

    Kang, Jing; Li, Xuwen; Geng, Jiayang; Han, Lu; Tang, Jieli; Jin, Yongri; Zhang, Yihua

    2012-10-15

    In this paper, 3-mercaptocarboxylic acid (MPA) modified CdTe quantum dots (QDs) were used as sensitizers, to enhance the chemiluminescence (CL) of the calcein/K(3)Fe(CN)(6) system. A new CL system of CdTe/calcein/K(3)Fe(CN)(6) was developed. The effects of reactant concentrations and the particle sizes of CdTe QDs on the CL emission were investigated in detail. The possible enhancement mechanism of the CL was also further investigated based on the photoluminescence (PL) and CL spectra. Polyphenols such as chlorogenic acid, quercetin, hyperin, catechin and kaempferol, were observed to inhibit the CL signal of the CdTe/calcein/K(3)Fe(CN)(6) system and determined by the proposed method. The proposed method was applied to the determination of hyperin in seed of Cuscuta chinensis Lam. and the results obtained were satisfactory. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Chemoluminescence measurement of 16 spices as a method to identify ionizing radiation treatment

    International Nuclear Information System (INIS)

    Heide, L.; Boegl, W.

    1984-09-01

    This report is based on a series of experiments conducted with 16 spices to find out whether the chemiluminescence intensity measurements of the reaction to luminol solution is appropriate as an indicator of treatment with ionizing radiation. For this purpose the optimum conditions of reaction were first assessed for each spice in order to determine the dependence of the chemiluminescence intensity on the radiation dose and storage time after irradiation. Only in garlic the irradiation was not able to be identified any more after 3 days of storage time. In most of the spices it is possible to take proof of radiation exposure even after storage times of more than 2 months. (orig./PW) [de

  20. Chemoluminescence measurement of 16 spices as a method to identify ionizing radiation treatment. Die Messung der Chemilumineszenz von 16 Gewuerzen als Nachweis einer Behandlung mit ionisierenden Strahlen

    Energy Technology Data Exchange (ETDEWEB)

    Heide, L; Boegl, W

    1984-09-01

    This report is based on a series of experiments conducted with 16 spices to find out whether the chemiluminescence intensity measurements of the reaction to luminol solution is appropriate as an indicator of treatment with ionizing radiation. For this purpose the optimum conditions of reaction were first assessed for each spice in order to determine the dependence of the chemiluminescence intensity on the radiation dose and storage time after irradiation. Only in garlic the irradiation was not able to be identified any more after 3 days of storage time. In most of the spices it is possible to take proof of radiation exposure even after storage times of more than 2 months.

  1. Determination of cyanide using a chemiluminescence system composed of permanganate, rhodamine B, and gold nanoparticles

    International Nuclear Information System (INIS)

    Amjadi, Mohammad; Hassanzadeh, Javad; Manzoori, Jamshid L.

    2014-01-01

    We describe a new chemiluminescence (CL) system based on the oxidation of rhodamine B (RhoB) with alkaline potassium permanganate in the presence of gold nanoparticles (Au-NPs) and anionic detergent sodium dodecyl sulfate. Free RhoB is weakly chemiluminescent when oxidized with permanganate at alkaline pH values. However, a remarkably strong enhancement of CL is observed in the presence of Au-NPs, probably due to a strong interaction between RhoB and the NPs. The possible mechanism was studied via recording the CL emission. It is also found that the intensity of CL gradually decreases in the presence of cyanide due to its interaction with the Au-NPs. The relation between the decreased CL intensity and cyanide concentration was exploited to develop a method for the determination of cyanide in the 0.01–0.5 μM concentration range, with a detection limit of 2.8 nM. The method was used to determine cyanide in spiked water, urine, and serum. (author)

  2. Antioxidant activity of Citrus paradisi seeds glyceric extract.

    Science.gov (United States)

    Giamperi, Laura; Fraternale, Daniele; Bucchini, Anahi; Ricci, Donata

    2004-03-01

    The antioxidant activity of Citrus paradisi (grapefruit) seeds glyceric extract dissolved in ethanol and in aqueous media was evaluated using three different methods: evaluation by DPPH assay, by 5-lipoxygenase assay and by luminol/xanthine/xanthine oxidase chemiluminescence assay. The total phenolic content was determined by the Prussian Blue method opportunely modified. The grapefruit seeds glyceric extract utilized as aqueous solutions demonstrated antioxidant properties better than those displayed by alcoholic solutions.

  3. Imaging and high-sensitivity quantification of chemiluminescent labeled DNA-blots

    International Nuclear Information System (INIS)

    Dorner, G.

    1997-01-01

    The present thesis has for objective the development of both, methods of DNA labeling by chemiluminescence (via the catalytic activity of the enzyme alkaline phosphatase - AP) and an appropriate imaging system. Offering a competitive alternative to the detection of classical radio-labels in molecular-biological experiments of the blotting type, this technique should permit the realization of quantitative studies of gene expression at ultra-high sensitivity necessary in particular for differential-screening experiments. To reach our aim. we separated the project into three different parts. In a first step an imager based on a liquid-nitrogen-cooled CCD coupled to a standard optics (50 mm/fl.2) has been installed and characterized. This system offers a sensitive area of up to 625 cm 2 , a spatial resolution of 0.3-1 mm (depending on the field of view) and a sensitivity sufficient to detect 10 fg/mm 2 labeled DNA. In a second part, the chemiluminescent light-generation process in solution has been investigated to optimize the parameters temperature. pH and concentration of the substrate as well as the enzyme. The substrate offering the highest light yield (CDP-Star in addition with the enhancer EMERALD II) allows quantification of AP down to 10 -15 M within a dynamic range of 10 4 in solution. Finally. preparation, immobilization and detection of AP-labeled DNA probes (via a biotin-streptavidin-biotin-AP bridge) on nylon membranes has been optimized. A linear relation between the light intensities and the amount of DNA was observed in a range of 10 fg/mm 2 - 100 pg/mm 2 . Hybridization of the probes to bacterial cloned target-DNA has been addressed after examination of the best hybridization conditions. Our protocol includes the treatment of a proteinase, which resulted in a significantly lower background on the filter. The results of our investigations suggest that the main conditions for a reliable differential-screening experiment are fulfilled when using

  4. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    International Nuclear Information System (INIS)

    Han, Dong-Wook; Lee, Jun Jae; Jung, Duk-Young; Park, Jong-Chul; Hyon, Suong-Hyu

    2009-01-01

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-ε-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  5. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong-Wook [Department of Nanomedical Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 609-735 (Korea, Republic of); Lee, Jun Jae [Division of Advanced Fibro-Science, Kyoto Institute of Technology, Kyoto 606-8585 (Japan); Jung, Duk-Young [Senior Products Industrial Center, Busan Techno-Park, Busan-617-030 (Korea, Republic of); Park, Jong-Chul [Cellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul 120-752 (Korea, Republic of); Hyon, Suong-Hyu, E-mail: nanohan@pusan.ac.k, E-mail: biogen@frontier.kyoto-u.ac.j [Department of Medical Simulation Engineering, Institute for Frontier Medical Sciences, Kyoto University, Kyoto 606-8507 (Japan)

    2009-08-15

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-epsilon-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  6. Chemiluminescence determination of ultramicro DNA with a flow-injection method

    Energy Technology Data Exchange (ETDEWEB)

    Chen Hui; Zhou Min; Jin Xiaoyong; Song Yumin; Zhang Ziyu; Ma Yongjun

    2002-02-12

    A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6x10{sup -5} to 0.26 {mu}g ml{sup -1} for calf thymus DNA and 5.0x10{sup -8} to 5.0x10{sup -5} {mu}g ml{sup -1} for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3{sigma}) are 6.5x10{sup -6} {mu}g ml{sup -1} for calf thymus DNA and 4.3x10{sup -8} {mu}g ml{sup -1} for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed.

  7. [Development and Application of Catalytic Tyrosine Modification].

    Science.gov (United States)

    Sato, Shinichi; Tsushima, Michihiko; Nakamura, Kosuke; Nakamura, Hiroyuki

    2018-01-01

     The chemical labeling of proteins with synthetic probes is a key technique used in chemical biology, protein-based therapy, and material science. Much of the chemical labeling of native proteins, however, depends on the labeling of lysine and cysteine residues. While those methods have significantly contributed to native protein labeling, alternative methods that can modify different amino acid residues are still required. Herein we report the development of a novel methodology of tyrosine labeling, inspired by the luminol chemiluminescence reaction. Tyrosine residues are often exposed on a protein's surface and are thus expected to be good targets for protein functionalization. In our studies so far, we have found that 1) hemin oxidatively activates luminol derivatives as a catalyst, 2) N-methyl luminol derivative specifically forms a covalent bond with a tyrosine residue among the 20 kinds of natural amino acid residues, and 3) the efficiency of tyrosine labeling with N-methyl luminol derivative is markedly improved by using horseradish peroxidase (HRP) as a catalyst. We were able to use molecular oxygen as an oxidant under HRP/NADH conditions. By using these methods, the functionalization of purified proteins was carried out. Because N-methyl luminol derivative is an excellent protein labeling reagent that responds to the activation of peroxidase, this new method is expected to open doors to such biological applications as the signal amplification of HRP-conjugated antibodies and the detection of protein association in combination with peroxidase-tag technology.

  8. Dendrimer-based biosensor for chemiluminescent detection of DNA hybridization

    International Nuclear Information System (INIS)

    Liu, P.; Hun, X.; Qing, H.

    2011-01-01

    We report on a highly sensitive chemiluminescent (CL) biosensor for the sequence-specific detection of DNA using a novel bio barcode DNA probe modified with gold nanoparticles that were covered with a dendrimer. The modified probe is composed of gold nanoparticles, a dendrimer, the CL reagent, and the DNA. The capture probe DNA was immobilized on magnetic beads covered with gold. It first hybridizes with the target DNA and then with one terminal end of the signal DNA on the barcoded DNA probe. CL was generated by adding H 2 O 2 and Co(II) ions as the catalyst. The immobilization of dendrimer onto the gold nanoparticles can significantly enhance sensitivity and gives a detection limit of 6 fmol L -1 of target DNA. (author)

  9. Determination of ethamsylate in pharmaceutical preparations based on an auto-oxidation chemiluminescence reaction.

    Science.gov (United States)

    Yang, Fengzhen; Zhang, Chao; Baeyens, Willy R G; Zhang, Xinrong

    2002-10-15

    Strong chemiluminescence emission has been observed by mixing alkaline hydrolytic products of ethamsylate with Tween 80 in acidic rhodamine 6G solution. This phenomenon has been utilized to design a flow-injection chemiluminescence method for the determination of ethamsylate in a pharmaceutical preparation. Under the optimum conditions, the proposed procedure has a linear range between 0.05 and 2.0 microg ml(-1), with a detection limit of 0.02 microg ml(-1) for ethamsylate. The method was applied to the determination of ethamsylate in pharmaceutical preparations. The possible mechanism of this chemiluminescence reaction was proposed. Copyright 2002 Elsevier Science B.V.

  10. Characteristic of peroxyoxalate-chemiluminescence intensity in the presence of Chlorpheniramine maleate and its analytical application

    International Nuclear Information System (INIS)

    Samadi-Maybodi, Abdolraouf; Akhoondi, Reza

    2011-01-01

    It has been shown that Chlorpheniramine maleate (CPM) increases chemiluminescence intensity of bis-(2,4,6-trichlorophenyl)oxalate (TCPO) with hydrogen peroxide in the presence of biphenylquinoxaline as a fluorophore. In this work, the effect of CPM on the intensity of chemiluminescence (CL) in the system of (TCPO-sodium salicylate-fluorophore-hydrogen peroxide) was investigated. The fall and rise rates constants were also studied. A pooled-intermediate model was used for determining the kinetics parameters of CL with and without CPM. Results indicated that addition of CMP to this system increases the fall rate constant and decreases the rise rate constant. Results also specified that there is a linear relationship between CPA concentration and chemiluminescence intensity in the range 0.66-21.5 μg/ml. Detection limit 0.18 μg/ml and the relative standard deviation (RSD) 2 O 2 - sodium salicylate- fluorescer) in the presence of chlorpheniramine maleate. → Results also introduced a reliable method for determination of chlorpheniramine using peroxyoxalte chemiluminescence system. → A pooled-intermediate model was used for determination the kinetics parameters of chemiluminescence with and without chlorpheniramine maleate. → Results also specified that there is a linear relationship between chlorpheniramine maleate concentration and chemiluminescence intensity.

  11. Elimination of hydrogen peroxide by Haemophilus somnus, a catalase-negative pathogen of cattle.

    OpenAIRE

    Sample, A K; Czuprynski, C J

    1991-01-01

    Haemophilus somnus is a catalase-negative, gram-negative pathogen of cattle which is refractory to killing by bovine neutrophils. In this report, we showed that H. somnus rapidly inhibited Luminol-dependent chemiluminescence of bovine neutrophils costimulated with opsonized zymosan or phorbol myristate acetate. We have postulated that this inhibition resulted in part from H. somnus preventing the accumulation of hydrogen peroxide (H2O2) during the oxidative burst. In support of this hypothesi...

  12. Flow-through solid-phase based optical sensor for the multisyringe flow injection trace determination of orthophosphate in waters with chemiluminescence detection

    International Nuclear Information System (INIS)

    Morais, Ines P.A.; Miro, Manuel; Manera, Matias; Estela, Jose Manuel; Cerda, Victor; Souto, M. Renata S.; Rangel, Antonio O.S.S.

    2004-01-01

    In this work, a novel flow-through solid-phase based chemiluminescence (CL) optical sensor is described for the trace determination of orthophosphate in waters exploiting the multisyringe flow injection analysis (MSFIA) concept with multicommutation. The proposed time-based injection flow system relies upon the in-line derivatisation of the analyte with ammonium molybdate in the presence of vanadate, and the transient immobilisation of the resulting heteropolyacid in a N-vinylpyrrolidone/divinylbenzene copolymer packed spiral shape flow-through cell located in front of the window of a photomultiplier tube. The simultaneous injection of well-defined slugs of luminol in alkaline medium and methanol solution towards the packed reactor is afterwards performed by proper switching of the solenoid valves. Then, the light emission from the luminol oxidation by the oxidant species retained onto the sorbent material is readily detected. At the same time, the generated molybdenum-blue compound is eluted by the minute amount of injected methanol, rendering the system prepared for a new measuring cycle. Therefore, the devised sensor enables the integration of the solid-phase CL reaction with elution and detection of the emitted light without the typical drawbacks of the molybdenum-blue based spectrophotometric procedures regarding the excess of molybdate anion, which causes high background signals due to its self-reduction. The noteworthy features of the developed CL-MSFIA system are the feasibility to accommodate reactions with different pH requirements and the ability to determine trace levels of orthophosphate in high silicate content samples (Si/P ratios up to 500). Under the optimised conditions, a dynamic linear range from 5 to 50 μg P l -1 for a 1.8 ml sample, repeatability better than 3.0% and a quantification limit of 4 μg P l -1 were attained. The flowing stream system handles 11 analysis h -1 and has been successfully applied to the determination of trace levels of

  13. Revelado de manchas latentes: efectividad del luminol y evaluación de su efecto sobre el estudio del DNA Development of latent stains: effectiveness of luminol and evaluation of its effect on DNA analysis

    OpenAIRE

    A. Castelló Ponce; M. Álvarez Seguí; M. Miquel Feucht; F.A. Verdú Pascual

    2002-01-01

    Con frecuencia, las ropas manchadas de sangre durante un acto violento son lavadas para tratar de eliminar los vestigios. El análisis del DNA mediante PCR ha dotado a la criminalística de la posibilidad de estudiar indicios mínimos que, con otros métodos, sería imposible analizar. Este tipo de muestra plantea una mayor dificultad en la detección de la mancha. En el presente trabajo se analiza la sensibilidad del luminol para encontrar manchas de sangre invisibles. Sobre estas manchas se inten...

  14. Luminol testing in detecting modern human skeletal remains: a test on different types of bone tissue and a caveat for PMI interpretation.

    Science.gov (United States)

    Caudullo, Giorgio; Caruso, Valentina; Cappella, Annalisa; Sguazza, Emanuela; Mazzarelli, Debora; Amadasi, Alberto; Cattaneo, Cristina

    2017-01-01

    When forensic pathologists and anthropologists have to deal with the evaluation of the post-mortem interval (PMI) in skeletal remains, luminol testing is frequently performed as a preliminary screening method. However, the repeatability of this test on the same bone, as well as comparative studies on different bones of the same individual, has never been performed. Therefore, with the aim of investigating the influence that different types of bones may exert on the response to the luminol test, the present study analysed three different skeletal elements (femoral diaphysis, vertebra and cranial vault), gathered from ten recent exhumed skeletons (all with a 20-year PMI). The analysis was performed twice on the same bone after 2 months: the analysis at time 0 concerned the whole bone, whereas the second concerned only a part of the same bone taken during the first test (which already had been broken). The overall results showed different responses, depending on the type of bone and on the integrity of the samples. Negative results at the first analysis (6.6% out of the total of samples) are consistent with what is reported in the literature, whilst at the second analysis, the increase of about 20% of false-negative results highlights that the luminol test ought to be performed with caution in case of broken bones or elements which are taphonomically altered. Results have thus proven that the exposition to environmental agents might result in haemoglobin (Hb) loss, as detected even after only 2 months. The study also focused on the crucial issue of the type of bone subjected to testing, remarking the suitability of the femoral diaphysis (100% of positive responses at the first analysis vs only 18% of false-negative results at the second test, corresponding to 5% of total false-negative results) as opposed to other bone elements that showed a low yield. In particular, the cranial vault gave poor results, with 40% of discrepancy between results from the two analyses

  15. Utilization of the human cell line HL-60 for chemiluminescence based detection of microorganisms and related substances

    DEFF Research Database (Denmark)

    Timm, Michael; Hansen, Erik W; Moesby, Lise

    2006-01-01

    species (ROS) when challenged with pyrogenic substances. In a luminol enhanced chemilumimetric assay the responsiveness of differentiated HL-60 cells is tested towards Salmonella typhimurium, Bacillus subtilis, Saccharomyces cerevisiae, Candida albicans, lipopolysaccharide (LPS) and lipoteichoic acid (LTA......). The results show a poor sensitivity to S. typhimurium but displays good sensitivity towards B. subtilis, LTA and LPS. Furthermore, the sensitivity towards the yeasts C. albicans and S. cerevisiae is considerably better than obtained in other in vitro cell systems. Overall these results indicate that the HL-60...... cell assay possibly could be evolved to a supplementary assay for the known pyrogenic detection assays. Furthermore, the utilization of the assay for pyrogenic examination of recombinant drugs derived from yeast expression systems would be relevant to examine....

  16. Laser-saturated fluorescence of nitric oxide and chemiluminescence measurements in premixed ethanol flames

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Carla S.T.; Barreta, Luiz G.; Sbampato, Maria E.; dos Santos, Alberto M. [Aerothermodynamic and Hypersonic Division, Institute of Advanced Studies - General Command of Aerospatial Technology, Rodovia dos Tamoios, km 5.5, 12228-001 Sao Jose dos Campos - SP (Brazil)

    2010-11-15

    In this study, nitric oxide laser-saturated fluorescence (LSF) measurements were acquired from premixed ethanol flames at atmospheric pressure in a burner. NO-LSF experimental profiles for fuel-rich premixed ethanol flames ({phi} = 1.34 and {phi} = 1.66) were determined through the excitation/detection scheme of the Q{sub 2}(26.5) rotational line in the A{sup 2}{sigma}{sup +} - X{sup 2}{pi} (0,0) vibronic band and {gamma}(0,1) emission band. A calibration procedure by NO doping into the flame was applied to establish the NO concentration profiles in these flames. Chemiluminescent emission measurements in the (0, 0) vibronic emission bands of the OH{sup *} (A{sup 2}{sigma}{sup +} - X{sup 2}{pi}) and CH{sup *}(A{sup 2}{delta} - X{sup 2}{pi}) radicals were also obtained with high spatial and spectral resolution for fuel-rich premixed ethanol flames to correlate them with NO concentrations. Experimental chemiluminescence profiles and the ratios of the integrated areas under emission spectra (A{sub CH*}/A{sub CH*}(max.) and A{sub CH*}/A{sub OH*}) were determined. The relationships between chemiluminescence and NO concentrations were established along the premixed ethanol flames. There was a strong connection between CH{sup *} radical chemiluminescence and NO formation and the prompt-NO was identified as the governing mechanism for NO production. The results suggest the optimum ratio of the chemiluminescence of two radicals (A{sub CH*}/A{sub OH*}) for NO diagnostic purposes. (author)

  17. A cascade amplification strategy based on rolling circle amplification and hydroxylamine amplified gold nanoparticles enables chemiluminescence detection of adenosine triphosphate.

    Science.gov (United States)

    Wang, Ping; Zhang, Tonghuan; Yang, Taoyi; Jin, Nan; Zhao, Yanjun; Fan, Aiping

    2014-08-07

    A highly sensitive and selective chemiluminescent (CL) biosensor for adenosine triphosphate (ATP) was developed by taking advantage of the ATP-dependent enzymatic reaction (ATP-DER), the powerful signal amplification capability of rolling circle amplification (RCA), and hydroxylamine-amplified gold nanoparticles (Au NPs). The strategy relies on the ability of ATP, a cofactor of T4 DNA ligase, to trigger the ligation-RCA reaction. In the presence of ATP, the T4 DNA ligase catalyzes the ligation reaction between the two ends of the padlock probe, producing a closed circular DNA template that initiates the RCA reaction with phi29 DNA polymerase and dNTP. Therein, many complementary copies of the circular template can be generated. The ATP-DER is eventually converted into a detectable CL signal after a series of processes, including gold probe hybridization, hydroxylamine amplification, and oxidative gold metal dissolution coupled with a simple and sensitive luminol CL reaction. The CL signal is directly proportional to the ATP level. The results showed that the detection limit of the assay is 100 pM of ATP, which compares favorably with those of other ATP detection techniques. In addition, by taking advantage of ATP-DER, the proposed CL sensing system exhibits extraordinary specificity towards ATP and could distinguish the target molecule ATP from its analogues. The proposed method provides a new and versatile platform for the design of novel DNA ligation reaction-based CL sensing systems for other cofactors. This novel ATP-DER based CL sensing system may find wide applications in clinical diagnosis as well as in environmental and biomedical fields.

  18. Determination of phenolic compounds using high-performance liquid chromatography with Ce4+-Tween 20 chemiluminescence detection

    International Nuclear Information System (INIS)

    Cui Hua; Zhou Jian; Xu Feng; Lai Chunze; Wan Guohui

    2004-01-01

    A novel method for the simultaneous determination of phenolic compounds such as salicylic acid, resorcinol, phloroglucinol, p-hydroxybenzoic acid, 2,4-dihydroxybenzoic acid, and m-nitrophenol by high-performance liquid chromatography (HPLC) coupled with chemiluminescence (CL) detection was developed. The procedure was based on the chemiluminescent enhancement by phenolic compounds of the cerium(IV)-Tween 20 system in a sulfuric acid medium. The separation was carried out with an isocratic elution or with a gradient elution using a mixture of methanol and 1.5% acetic acid. For six phenolic compounds, the detection limits (3σ) were in the range 1.40-5.02 ng/ml and the relative standard deviations (n=11) for the determination of 0.1 μg/ml compounds were in the range 1.9-2.9%. The CL reaction was well compatible with the mobile phase of HPLC, no baseline drift often occurred in HPLC-CL detection was observed with a gradient elution. The method has been successfully applied to the determination of salicylic acid and resorcinol in Dermatitis Clear Tincture and p-hydroxybenzoic acid in apple juices

  19. Enhancement of periodate-hydrogen peroxide chemiluminescence by nitrogen doped carbon dots and its application for the determination of pyrogallol and gallic acid.

    Science.gov (United States)

    Shah, Syed Niaz Ali; Li, Haifang; Lin, Jin-Ming

    2016-06-01

    A new sensitized chemiluminescence (CL) was developed to broaden the analytical application of KIO4-H2O2 system. The nitrogen doped carbon dots (N-CDs) dramatically boosted the CL intensity of KIO4-H2O2 system which was further enriched by basic medium. In light of EPR analysis, free radical scavenging studies and CL spectra the detail mechanism for the enhancement was conferred in the presence of N-CDs and NaOH. The results suggested that CL of KIO4-H2O2 system in the presence and absence of N-CDs and NaOH proceeds via radical pathway. The enhanced CL was used for the determination of pyrogallol and gallic acid in range of 1.0×10(-4)-1.0×10(-7)M with 4.6×10(-8) and 6.1×10(-8)M limit of detection respectively. The relative standard deviation (RSD) at a concentration of 10(-5) for gallic acid and pyrogallol was 1.4% and 2.3% respectively (n=11). The attained results unveil that the present method is sensitive, faster, simpler and less costly compared to other methods and could be applied to determine polyphenols in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Solid-state chemiluminescence assay for ultrasensitive detection of antimony using on-vial immobilization of CdSe quantum dots combined with liquid–liquid–liquid microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Costas-Mora, Isabel; Romero, Vanesa; Lavilla, Isela; Bendicho, Carlos, E-mail: bendicho@uvigo.es

    2013-07-25

    Graphical abstract: -- Highlights: •Solid-state chemiluminescence based on CdSe QDs was developed. •QDs immobilization in a vial was achieved in a simple and fast way. •Antimony detection was achieved by inhibition of the CdSe QDs/H{sub 2}O{sub 2} CL reaction. •LLLME allowed improving the selectivity and sensitivity of the CL assay. •The capping ligand played a critical role in the selectivity of the CL system. -- Abstract: On-vial immobilized CdSe quantum dots (QDs) are applied for the first time as chemiluminescent probes for the detection of trace metal ions. Among 17 metal ions tested, inhibition of the chemiluminescence when CdSe QDs are oxidized by H{sub 2}O{sub 2} was observed for Sb, Se and Cu. Liquid–liquid–liquid microextraction was implemented in order to improve the selectivity and sensitivity of the chemiluminescent assay. Factors influencing both the CdSe QDs/H{sub 2}O{sub 2} chemiluminescent system and microextraction process were optimized for ultrasensitive detection of Sb(III) and total Sb. In order to investigate the mechanism by which Sb ions inhibit the chemiluminescence of the CdSe QDs/H{sub 2}O{sub 2} system, atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), UV–vis absorption and fluorescence measurements were performed. The selection of the appropriate CdSe QDs capping ligand was found to be a critical issue. Immobilization of QDs caused the chemiluminescence signal to be enhanced by a factor of 100 as compared to experiments carried out with QDs dispersed in the bulk aqueous phase. Under optimized conditions, the detection limit was 6 ng L{sup −1} Sb and the repeatability expressed as relative standard deviation (N = 7) was about 1.3%. An enrichment factor of 95 was achieved within only 3 min of microextraction. Several water samples including drinking, spring, and river waters were analyzed. The proposed method was validated against CRM NWTM-27.2 fortified lake water, and a recovery study was

  1. Forensic Luminol Blood Test for Preventing Cross-contamination in Dentistry: An Evaluation of a Dental School Clinic

    OpenAIRE

    Marcelo Carlos Bortoluzzi; Peterson Cadore; Andrea Gallon; Soraia Almeida Watanabe Imanishi

    2014-01-01

    Background: More than 200 different diseases may be transmitted from exposure to blood in the dental setting. The aim of this study is to identify possible faults in the cross-contamination chain control in a dental school clinic searching for traces of blood in the clinical contact surfaces (CCS) through forensic luminol blood test. Methods: Traces of invisible blood where randomly searched in CCS of one dental school clinic. Results: Forty eight surfaces areas in the CCS were tes...

  2. Involvement of both protein kinase C and G proteins in superoxide production after IgE triggering in guinea pig eosinophils

    Directory of Open Access Journals (Sweden)

    Toshiya Aizawa

    1997-01-01

    Full Text Available To study the function and mechanism of eosinophils via the low affinity IgE receptor (FceRII, we examined the production of 02 metabolites by measuring the luminol-dependent chemiluminescence (LDCL response and the generation of cysteinyl leukotrienes. Eosinophils obtained from guinea pig peritoneal fluid sensitized with horse serum were purified. Luminol-dependent chemiluminescence was induced by stimulation with monoclonal anti-CD23 antibody, but not by mouse serum (controls. The mean (±SEM value of LDCL was 20.6±1.3X103 c.p.m. This reaction consisted of an initial rapid phase and a propagation phase and ended within lOmin. Guinea pig eosinophils were histochemically stained with monoclonal anti-CD23 antibody. The major product generated in the LDCL response was superoxide, as determined by the measurement of superoxide by cytochrome c reduction and the complete inhibitory effect of superoxide dismutase on the LDCL response. Pretreatment with either pertussis toxin or cholera toxin inhibited the LDCL reaction. Depletion of bivalent ions by EDTA inhibited this response and the protein kinase C inhibitor D-sphingosin inhibited both 1-oleoyl-2-acetyl-glycerol-induced and FcϵRII-mediated LDCL. These findings suggest that the NADPH-protein kinase C pathway may be involved in the FceRII-mediated LDCL response in guinea pig eosinophils.

  3. Antioxidant potential of six pine species.

    Science.gov (United States)

    Guri, Anilda; Kefalas, Panagiotis; Roussis, Vassilios

    2006-04-01

    The aim of the study was to evaluate the antioxidant efficacy of extracts obtained from six Pinus species (P. pinea, P. brutia, P. radiata, P. halepensis, P. attenuata, P. nigra) growing in natural forests in Southern Greece. Specimens of fresh, dry needles and pine bark were extracted and fractionated with a variety of organic solvents and the efficient concentration and their radical scavenging activity was evaluated by the Co(II)/EDTA induced luminol plateau chemiluminescence assay. Copyright 2006 John Wiley & Sons, Ltd.

  4. Screening test for rapid food safety evaluation by menadione-catalysed chemiluminescent assay.

    Science.gov (United States)

    Yamashoji, Shiro; Yoshikawa, Naoko; Kirihara, Masayuki; Tsuneyoshi, Toshihiro

    2013-06-15

    The chemiluminescent assay of menadione-catalysed H2O2 production by living mammalian cells was proposed to be useful for rapid food safety evaluation. The tested foods were extracted with water, ethanol and dimethylsulfoxide, and each extract was incubated with NIH3T3, Neuro-2a and HepG2 cells for 4h. Menadione-catalysed H2O2 production by living mammalian cells exposed to each extract was determined by the chemiluminescent assay requiring only 10 min, and the viability of the cells was estimated as percentage based on H2O2 production by intact cells. In this study the cytotoxicity of food was rated in order of inhibitory effect on H2O2 production by intact cells. The well known natural toxins such as Fusarium mycotoxin, tomato toxin tomatine, potato toxin solanine and marine toxins terodotoxin and brevetoxin could be detected by the above chemiluminescent assay. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. A competitive chemiluminescence enzyme immunoassay for rapid and sensitive determination of enrofloxacin

    Science.gov (United States)

    Yu, Fei; Wu, Yongjun; Yu, Songcheng; Zhang, Huili; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B.

    With alkaline phosphatase (ALP)-adamantane (AMPPD) system as the chemiluminescence (CL) detection system, a highly sensitive, specific and simple competitive chemiluminescence enzyme immunoassay (CLEIA) was developed for the measurement of enrofloxacin (ENR). The physicochemical parameters, such as the chemiluminescent assay mediums, the dilution buffer of ENR-McAb, the volume of dilution buffer, the monoclonal antibody concentration, the incubation time, and other relevant variables of the immunoassay have been optimized. Under the optimal conditions, the detection linear range of 350-1000 pg/mL and the detection limit of 0.24 ng/mL were provided by the proposed method. The relative standard deviations were less than 15% for both intra and inter-assay precision. This method has been successfully applied to determine ENR in spiked samples with the recovery of 103%-96%. It showed that CLEIA was a good potential method in the analysis of residues of veterinary drugs after treatment of related diseases.

  6. Flame structure of methane/oxygen shear coaxial jet with velocity ratio using high-speed imaging and OH*, CH* chemiluminescence

    Science.gov (United States)

    Shim, Myungbo; Noh, Kwanyoung; Yoon, Woongsup

    2018-06-01

    In this study, the effects of gaseous methane/oxygen injection velocity ratio on the shear coaxial jet flame structure are analyzed using high-speed imaging along with OH* and CH* chemiluminescence. The images show that, as the velocity ratio is increased, the visual flame length increases and wrinkles of the flame front are developed further downstream. The region near the equivalence ratio 1 condition in the flame could be identified by the maximum OH* position, and this region is located further downstream as the velocity ratio is increased. The dominant CH* chemiluminescence is found in the near-injector region. As the velocity ratio is decreased, the signal intensity is higher at the same downstream distance in each flame. From the results, as the velocity ratio is decreased, there is increased entrainment of the external jet, the mixing of the two jets is enhanced, the region near the stoichiometric mixture condition is located further upstream, and consequently, the flame length decreases.

  7. Antioxidant effects of herbal therapies used by patients with inflammatory bowel disease: an in vitro study.

    Science.gov (United States)

    Langmead, L; Dawson, C; Hawkins, C; Banna, N; Loo, S; Rampton, D S

    2002-02-01

    Herbal remedies used by patients for treatment of inflammatory bowel disease include slippery elm, fenugreek, devil's claw, Mexican yam, tormentil and wei tong ning, a traditional Chinese medicine. Reactive oxygen metabolites produced by inflamed colonic mucosa may be pathogenic. Aminosalicylates (5-ASA) are antioxidant and other such agents could be therapeutic. To assess the antioxidant effects of herbal remedies in cell-free oxidant-generating systems and inflamed human colorectal biopsies. Luminol-enhanced chemiluminescence in a xanthine/xanthine oxidase cell-free system was used to detect superoxide scavenging by herbs and 5-ASA, and fluorimetry to define peroxyl radical scavenging using a phycoerythrin degradation assay. Chemiluminescence was used to detect herbal effects on generation of oxygen radicals by mucosal biopsies from patients with active ulcerative colitis. Like 5-ASA, all herbs, except fenugreek, scavenged superoxide dose-dependently. All materials tested scavenged peroxyl dose-dependently. Oxygen radical release from biopsies was reduced after incubation in all herbs except Mexican yam, and by 5-ASA. All six herbal remedies have antioxidant effects. Fenugreek is not a superoxide scavenger, while Mexican yam did not inhibit radical generation by inflamed biopsies. Slippery elm, fenugreek, devil's claw, tormentil and wei tong ning merit formal evaluation as novel therapies in inflammatory bowel disease.

  8. Analysis of chemiluminescence measurements by grey-scale ICCD and colour digital cameras

    International Nuclear Information System (INIS)

    Migliorini, F; Maffi, S; De Iuliis, S; Zizak, G

    2014-01-01

    Spectral, grey-scale and colour chemiluminescence measurements of C 2 * and CH* radicals' emission are carried out on the flame front of a methane–air premixed flame at different equivalence ratios. To this purpose, properly spatially resolved optical equipment has been implemented in order to reduce the background emission from other burned gas regions. The grey-scale (ICCD + interference filters) and RGB colour (commercial digital camera) approaches have been compared in order to find a correspondence between the C 2 * and the green component, as well as the CH* and the blue component of the emission intensities. The C 2 */CH* chemiluminescence ratio has been investigated at different equivalence ratios and a good correlation has been obtained, showing the possibility of sensing the equivalence ratio in practical systems. The grey-scale and colour chemiluminescence analysis has then been applied to a meso-scale not premixed swirl combustor fuelled with a methane–air mixture and operating at 0.3 MPa. 2D results are presented and discussed in this work. (paper)

  9. Decreased activity of neutrophils in the presence of diferuloylmethane (curcumin) involves protein kinase C inhibition.

    Science.gov (United States)

    Jancinová, Viera; Perecko, Tomás; Nosál, Radomír; Kostálová, Daniela; Bauerová, Katarína; Drábiková, Katarína

    2009-06-10

    Diferuloylmethane (curcumin) has been shown to act beneficially in arthritis, particularly through downregulated expression of proinflammatory cytokines and collagenase as well as through the modulated activities of T lymphocytes and macrophages. In this study its impact on activated neutrophils was investigated both in vitro and in experimental arthritis. Formation of reactive oxygen species in neutrophils was recorded on the basis of luminol- or isoluminol-enhanced chemiluminescence. Phosphorylation of neutrophil protein kinases C alpha and beta II was assessed by Western blotting, using phosphospecific antibodies. Adjuvant arthritis was induced in Lewis rats by heat-killed Mycobacterium butyricum. Diferuloylmethane or methotrexate was administered over a period of 28 days after arthritis induction. Under in vitro conditions, diferuloylmethane (1-100 microM) reduced dose-dependently oxidant formation both at extra- and intracellular level and it effectively reduced protein kinase C activation. Adjuvant arthritis was accompanied by an increased number of neutrophils in blood and by a more pronounced spontaneous as well as PMA (phorbol myristate acetate) stimulated chemiluminescence. Whereas the arthritis-related alterations in neutrophil count and in spontaneous chemiluminescence were not modified by diferuloylmethane, the increased reactivity of neutrophils to PMA was less evident in diferuloylmethane-treated animals. The effects of diferuloylmethane were comparable with those of methotrexate. Diferuloylmethane was found to be a potent inhibitor of neutrophil functions both in vitro and in experimental arthritis. As neutrophils are considered to be cells with the greatest capacity to inflict damage within diseased joints, the observed effects could represent a further mechanism involved in the antirheumatic activity of diferuloylmethane.

  10. Quantum dots assisted photocatalysis for the chemiluminometric determination of chemical oxygen demand using a single interface flow system

    Energy Technology Data Exchange (ETDEWEB)

    Silvestre, Cristina I.C.; Frigerio, Christian [Requimte, Department of Chemistry, Faculty of Pharmacy, Porto University, Rua Anibal Cunha 164, 4099-030, Porto (Portugal); Santos, Joao L.M., E-mail: joaolms@ff.up.pt [Requimte, Department of Chemistry, Faculty of Pharmacy, Porto University, Rua Anibal Cunha 164, 4099-030, Porto (Portugal); Lima, Jose L.F.C. [Requimte, Department of Chemistry, Faculty of Pharmacy, Porto University, Rua Anibal Cunha 164, 4099-030, Porto (Portugal)

    2011-08-12

    Highlights: {yields} A novel flow method for the determination of chemical oxygen demand is proposed. {yields} CdTe nanocrystals are irradiated with UV light to generate strong oxidizing species. {yields} Reactive species promote a fast catalytic degradation of organic matter. {yields} Luminol is used as a chemiluminescence probe for indirect COD assessment. {yields} A single interface flow system was implemented to automate the assays. - Abstract: A novel flow method for the determination of chemical oxygen demand (COD) is proposed in this work. It relies on the combination of a fully automated single interface flow system, an on-line UV photocatalytic unit and quantum dot (QD) nanotechnology. The developed approach takes advantage of CdTe nanocrystals capacity to generate strong oxidizing species upon irradiation with UV light, which fostered a fast catalytic degradation of the organic compounds. Luminol was used as a chemiluminescence (CL) probe for indirect COD assessment, since it is easily oxidized by the QD generated species yielding a strong CL emission that is quenched in the presence of the organic matter. The proposed methodology allowed the determination of COD concentrations between 1 and 35 mg L{sup -1}, with good precision (R.S.D. < 1.1%, n = 3) and a sampling frequency of about 33 h{sup -1}. The procedure was applied to the determination of COD in wastewater certified reference materials and the obtained results showed an excellent agreement with the certified values.

  11. On-line monitoring of Glucose and penicillin by sequential injection analysis

    DEFF Research Database (Denmark)

    Min, R.W.; Nielsen, Jens Bredal; Villadsen, John

    1996-01-01

    and a detector. The glucose analyzer is based on an enzymatic reaction using glucose oxidase, which converts glucose to glucono-lactone with formation of hydrogen peroxide and subsequent detection of H2O2 by a chemiluminescence reaction involving luminol. The penicillin analysis is based on formation......A sequential injection analysis (SIA) system has been developed for on-line monitoring of glucose and penicillin during cultivations of the filamentous fungus Penicillium chrysogenum. The SIA system consists of a peristaltic pump, an injection valve, two piston pumps, two multi-position valves...

  12. An enhanced cerium(IV)-rhodamine 6G chemiluminescence system using guest-host interactions in a lab-on-a-chip platform for estimating the total phenolic content in food samples.

    Science.gov (United States)

    Al Haddabi, Buthaina; Al Lawati, Haider A J; Suliman, FakhrEldin O

    2016-04-01

    Two chemiluminescence-microfluidic (CL-MF) systems, e.g., Ce(IV)-rhodamine B (RB) and Ce(IV)-rhodamine 6G (R6G), for the determination of the total phenolic content in teas and some sweeteners were evaluated. The results indicated that the Ce(IV)-R6G system was more sensitive in comparison to the Ce(IV)-RB CL system. Therefore, a simple (CL-MF) method based on the CL of Ce(IV)-R6G was developed, and the sensitivity, selectivity and stability of this system were evaluated. Selected phenolic compounds (PCs), such as quercetin (QRC), catechin (CAT), rutin (RUT), gallic acid (GA), caffeic acid (CA) and syringic acid (SA), produced analytically useful chemiluminescence signals with low detection limits ranging from 0.35 nmol L(-1) for QRC to 11.31 nmol L(-1) for SA. The mixing sequence and the chip design were crucial, as the sensitivity and reproducibility could be substantially affected by these two factors. In addition, the anionic surfactant (i.e., sodium dodecyl sulfate (SDS)) can significantly enhance the CL signal intensity by as much as 300% for the QRC solution. Spectroscopic studies indicated that the enhancement was due to a strong guest-host interaction between the cationic R6G molecules and the anionic amphiphilic environment. Other parameters that could affect the CL intensities of the PCs were carefully optimized. Finally, the method was successfully applied to tea and sweetener samples. Six different tea samples exhibited total phenolic/antioxidant levels from 7.32 to 13.5 g per 100g of sample with respect to GA. Four different sweetener samples were also analyzed and exhibited total phenolic/antioxidant levels from 500.9 to 3422.9 mg kg(-1) with respect to GA. The method was selective, rapid and sensitive when used to estimate the total phenolic/antioxidant level, and the results were in good agreement with those reported for honey and tea samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Comparison of ultraviolet absorbance and NO-chemiluminescence for ozone measurement in wildfire plumes at the Mount Bachelor Observatory

    Science.gov (United States)

    Gao, Honglian; Jaffe, Daniel A.

    2017-10-01

    The goal of this paper is to evaluate the accuracy of the commonly used ozone (O3) instrument (the ultraviolet (UV) photometer) against a Federal Reference Method (Nitric Oxide -chemiluminescence) for ozone measurement in wildfire smoke plumes. We carried out simultaneous ozone measurement with two UV O3 photometers and one nitric oxide-chemiluminescence (NO-CL) ozone detectors during wildfire season (Aug. 1-Sept. 30) in 2015 at the Mount Bachelor Observatory (MBO, 2763 m above mean sea level, Oregon, USA). The UV O3 shows good agreement and excellent correlation to NO-CL O3, with linear regression slopes close to unity and R2 of 0.92 for 1-h average data and R2 of 0.93 for O3 daily maximum 8-h average (MDA8). During this two-month period we identified 35 wildfire events. Ozone enhancements in those wildfire plumes measured by NO-CL O3 and UV O3 monitors also show good agreement and excellent linear correlation, with a slope and R2 of 1.03 and 0.86 for O3 enhancements (ΔO3) and 1.00 and 0.98 for carbon monoxide (CO)-normalized ozone enhancement ratios (ΔO3/ΔCO), respectively. Overall, the UV O3 was found to have a positive bias of 4.7 ± 2.8 ppbv compared to the NO-CL O3. The O3 bias between NO-CL O3 and UV O3 is independent of wildfire plume tracers such as CO, particulate matter (PM1), aerosol scattering, and ultrafine particles. The results demonstrate that the UV O3 absorbance method is reliable, even in highly concentrated wildfire plumes.

  14. Projection model for flame chemiluminescence tomography based on lens imaging

    Science.gov (United States)

    Wan, Minggang; Zhuang, Jihui

    2018-04-01

    For flame chemiluminescence tomography (FCT) based on lens imaging, the projection model is essential because it formulates the mathematical relation between the flame projections captured by cameras and the chemiluminescence field, and, through this relation, the field is reconstructed. This work proposed the blurry-spot (BS) model, which takes more universal assumptions and has higher accuracy than the widely applied line-of-sight model. By combining the geometrical camera model and the thin-lens equation, the BS model takes into account perspective effect of the camera lens; by combining ray-tracing technique and Monte Carlo simulation, it also considers inhomogeneous distribution of captured radiance on the image plane. Performance of these two models in FCT was numerically compared, and results showed that using the BS model could lead to better reconstruction quality in wider application ranges.

  15. Numerical and Experimental Investigation of Computed Tomography of Chemiluminescence for Hydrogen-Air Premixed Laminar Flames

    Directory of Open Access Journals (Sweden)

    Liang Lv

    2016-01-01

    Full Text Available Computed tomography of chemiluminescence (CTC is a promising technique for combustion diagnostics, providing instantaneous 3D information of flame structures, especially in harsh circumstance. This work focuses on assessing the feasibility of CTC and investigating structures of hydrogen-air premixed laminar flames using CTC. A numerical phantom study was performed to assess the accuracy of the reconstruction algorithm. A well-designed burner was used to generate stable hydrogen-air premixed laminar flames. The OH⁎ chemiluminescence intensity field reconstructed from 37 views using CTC was compared to the OH⁎ chemiluminescence distributions recorded directly by a single ICCD camera from the side view. The flame structures in different flow velocities and equivalence ratios were analyzed using the reconstructions. The results show that the CTC technique can effectively indicate real distributions of the flame chemiluminescence. The height of the flame becomes larger with increasing flow velocities, whereas it decreases with increasing equivalence ratios (no larger than 1. The increasing flow velocities gradually lift the flame reaction zones. A critical cone angle of 4.76 degrees is obtained to avoid blow-off. These results set up a foundation for next studies and the methods can be further developed to reconstruct 3D structures of flames.

  16. Identification of irradiated spices with aid of scintillation counter

    International Nuclear Information System (INIS)

    Uusheimo, K.

    1989-08-01

    The aim off the work was to determine how one can identify gamma-irradiated spices with aid of a scintillation counter (LKB/Wallac 1219 RackBeta Spectral) by chemiluminescence measurements. Even though scintillation counters are more sensitive than real luminometers they have not been capable in identifying the irradiated spices after contact with photosensitizer like luminol, isoluminol and lucigenin presumably because the actual chemiluminescence reaction took place before the sample vial reached the measuring range. Whereas it was noticed that the identification of pure, dry allspice, black pepper, white peppar and cardemom was possible without any solutions when there were also present similar unirradiated spices. The identification was possible even after 23 weeks duration depending on the dose of the irradiation (10 kGy or 50 kGy) and the weight of the samples (1 g or 9 g). The duration of the investigation was 23 weeks

  17. Chemiluminescence in cryogenic matrices

    Science.gov (United States)

    Lotnik, S. V.; Kazakov, Valeri P.

    1989-04-01

    The literature data on chemiluminescence (CL) in cryogenic matrices have been classified and correlated for the first time. The role of studies on phosphorescence and CL at low temperatures in the development of cryochemistry is shown. The features of low-temperature CL in matrices of nitrogen and inert gases (fine structure of spectra, matrix effects) and the data on the mobility and reactivity of atoms and radicals at very low temperatures are examined. The trends in the development of studies on CL in cryogenic matrices, such as the search for systems involving polyatomic molecules and extending the forms of CL reactions, are followed. The reactions of active nitrogen with hydrocarbons that are accompanied by light emission and CL in the oxidation of carbenes at T >= 77 K are examined. The bibliography includes 112 references.

  18. Enhanced chemiluminescence of the luminol–KMnO4 system by CuO nanosheets and its application for determination of meropenem in water and human serum

    International Nuclear Information System (INIS)

    Khataee, A.R.; Fathinia, M.; Hasanzadeh, A.; Iranifam, M.; Moradkhannejhad, L.

    2014-01-01

    CuO nanosheets were synthesized by an easy and green sonochemical method. It was found that, CuO nanosheets could significantly catalyze the chemiluminescence (CL) reaction of luminol–KMnO 4 in an alkaline condition. Based on this finding, a new CL system (luminol–KMnO 4 –CuO nanosheets) combined with flow injection analysis has been developed for the determination of meropenem for the first time. Moreover, the CL intensity was enhanced when meropenem was presented in the reaction system. Under the optimum conditions, the enhanced CL intensity was proportional to the concentration of meropenem in the ranges of 0.005–6.00 mg L −1 , with a detection limit (3σ) of 0.0036 mg L −1 . The precision of the method was calculated by analyzing samples containing 1.0 mg L −1 meropenem (n=11) and the relative standard deviation (RSD) was 1.7%. Also, a total analysis time per sample was 30 s which confirmed the rapidity of the proposed assay. The practicality of the proposed CL system was evaluated by determining meropenem in spiked environmental water samples and human serum. A discussion on the possible CL reaction mechanism was also presented. - Highlights: • CuO nanosheets (NSs) were successfully prepared by a green sonochemical method. • CuO NSs were found to be an excellent enhancer for luminol−KMnO 4 CL system. • Meropenem was determined using a novel luminol−KMnO 4 −CuO NSs flow injection CL system. • The enhancement mechanism of meropenem on the CL emission was proposed. • Appropriate sensitivity and selectivity were notable features of the proposed method

  19. The oxidant-scavenging abilities in the oral cavity may be regulated by a collaboration among antioxidants in saliva, microorganisms, blood cells and polyphenols: a chemiluminescence-based study.

    Directory of Open Access Journals (Sweden)

    Isaac Ginsburg

    Full Text Available Saliva has become a central research issue in oral physiology and pathology. Over the evolution, the oral cavity has evolved the antioxidants uric acid, ascorbate reduced glutathione, plasma-derived albumin and antioxidants polyphenols from nutrients that are delivered to the oral cavity. However, blood cells extravasated from injured capillaries in gingival pathologies, or following tooth brushing and use of tooth picks, may attenuate the toxic activities of H2O2 generated by oral streptococci and by oxidants generated by activated phagocytes. Employing a highly sensitive luminol-dependent chemiluminescence, the DPPH radical and XTT assays to quantify oxidant-scavenging abilities (OSA, we show that saliva can strongly decompose both oxygen and nitrogen species. However, lipophilic antioxidant polyphenols in plants, which are poorly soluble in water and therefore not fully available as effective antioxidants, can nevertheless be solubilized either by small amounts of ethanol, whole saliva or also by salivary albumin and mucin. Plant-derived polyphenols can also act in collaboration with whole saliva, human red blood cells, platelets, and also with catalase-positive microorganisms to decompose reactive oxygen species (ROS. Furthermore, polyphenols from nutrient can avidly adhere to mucosal surfaces, are retained there for long periods and may function as a "slow-release devises" capable of affecting the redox status in the oral cavity. The OSA of saliva is due to the sum result of low molecular weight antioxidants, albumin, polyphenols from nutrients, blood elements and microbial antioxidants. Taken together, saliva and its antioxidants are considered regulators of the redox status in the oral cavity under physiological and pathological conditions.

  20. The Oxidant-Scavenging Abilities in the Oral Cavity May Be Regulated by a Collaboration among Antioxidants in Saliva, Microorganisms, Blood Cells and Polyphenols: A Chemiluminescence-Based Study

    Science.gov (United States)

    Ginsburg, Isaac; Kohen, Ron; Shalish, Miri; Varon, David; Shai, Ella; Koren, Erez

    2013-01-01

    Saliva has become a central research issue in oral physiology and pathology. Over the evolution, the oral cavity has evolved the antioxidants uric acid, ascorbate reduced glutathione, plasma-derived albumin and antioxidants polyphenols from nutrients that are delivered to the oral cavity. However, blood cells extravasated from injured capillaries in gingival pathologies, or following tooth brushing and use of tooth picks, may attenuate the toxic activities of H2O2 generated by oral streptococci and by oxidants generated by activated phagocytes. Employing a highly sensitive luminol-dependent chemiluminescence, the DPPH radical and XTT assays to quantify oxidant-scavenging abilities (OSA), we show that saliva can strongly decompose both oxygen and nitrogen species. However, lipophilic antioxidant polyphenols in plants, which are poorly soluble in water and therefore not fully available as effective antioxidants, can nevertheless be solubilized either by small amounts of ethanol, whole saliva or also by salivary albumin and mucin. Plant-derived polyphenols can also act in collaboration with whole saliva, human red blood cells, platelets, and also with catalase-positive microorganisms to decompose reactive oxygen species (ROS). Furthermore, polyphenols from nutrient can avidly adhere to mucosal surfaces, are retained there for long periods and may function as a “slow- release devises” capable of affecting the redox status in the oral cavity. The OSA of saliva is due to the sum result of low molecular weight antioxidants, albumin, polyphenols from nutrients, blood elements and microbial antioxidants. Taken together, saliva and its antioxidants are considered regulators of the redox status in the oral cavity under physiological and pathological conditions. PMID:23658797

  1. A sniffer-camera for imaging of ethanol vaporization from wine: the effect of wine glass shape.

    Science.gov (United States)

    Arakawa, Takahiro; Iitani, Kenta; Wang, Xin; Kajiro, Takumi; Toma, Koji; Yano, Kazuyoshi; Mitsubayashi, Kohji

    2015-04-21

    A two-dimensional imaging system (Sniffer-camera) for visualizing the concentration distribution of ethanol vapor emitting from wine in a wine glass has been developed. This system provides image information of ethanol vapor concentration using chemiluminescence (CL) from an enzyme-immobilized mesh. This system measures ethanol vapor concentration as CL intensities from luminol reactions induced by alcohol oxidase and a horseradish peroxidase (HRP)-luminol-hydrogen peroxide system. Conversion of ethanol distribution and concentration to two-dimensional CL was conducted using an enzyme-immobilized mesh containing an alcohol oxidase, horseradish peroxidase, and luminol solution. The temporal changes in CL were detected using an electron multiplier (EM)-CCD camera and analyzed. We selected three types of glasses-a wine glass, a cocktail glass, and a straight glass-to determine the differences in ethanol emission caused by the shape effects of the glass. The emission measurements of ethanol vapor from wine in each glass were successfully visualized, with pixel intensity reflecting ethanol concentration. Of note, a characteristic ring shape attributed to high alcohol concentration appeared near the rim of the wine glass containing 13 °C wine. Thus, the alcohol concentration in the center of the wine glass was comparatively lower. The Sniffer-camera was demonstrated to be sufficiently useful for non-destructive ethanol measurement for the assessment of food characteristics.

  2. Reaction of uranium (IV) with xenon difluoride by chemiluminescence, spectrophotometric, and spectrofluorimetric methods

    Energy Technology Data Exchange (ETDEWEB)

    Mamykin, A.V.; Kazakov, V.P.

    1988-07-01

    A study is made of the kinetics of the chemiluminescent reaction of oxidation of uranium (IV) by xenon difluoride in 1M HClO/sub 4/ U/sup 4 +/ + XeF/sub 2/ ..-->.. UO/sub 2//sup 2 +/ = h/eta/. The optical density D and the intensity of the photoluminescence of the solution I/sub PL/ were measured in parallel with recording of the luminescence intensity I/sub CL/. I/sub CL/ attains a maximum value some time after the beginning of the reaction, after which it decays exponentially. On the kinetic curves of the time dependence of D and I/sub PL/ an induction period is observed, the extent of which depends on concentrations of reagents and temperature of the solution. The maximum of I/sub CL/ coincides with the end of the induction period if the measurements are carried out under identical conditions. The rate of the reaction after the induction period is described by a first order equation in U/sup (IV)/. The rate constants of the reaction, obtained by chemiluminescence, spectrophotometric, and spectrofluorimetric methods, have close values 2.0 +- 0.4, 1.8 +- 0.3, and 2.1 +- 0.3 sec/sup /minus/1/ x 10/sup 2/, respectively. On the basis of the results obtained, we conclude that the stages of formation of UO/sub 2//sup 2 +/ and of chemiluminescence coincide, i.e., formation of the excited state (UD/sub 2//sup 2 +/) and of chemiluminescence coincide, i.e., formation of the excited state (UD/sub 2//sup 2 +/)* takes place during the reaction. It is proposed and experimentally verified that the reaction passes through an intermediate stage of formation of uranyl ion UO/sub 2//sup +/.

  3. Chemiluminescence evidence supporting the selective role of ligands in the permanganate oxidation of micropollutants.

    Science.gov (United States)

    Roderick, Mark S; Adcock, Jacqui L; Terry, Jessica M; Smith, Zoe M; Parry, Samuel; Linton, Stuart M; Thornton, Megan T; Barrow, Colin J; Francis, Paul S

    2013-10-10

    The selective increase in the oxidation rate of certain organic compounds with permanganate in the presence of environmental "ligands" and reduced species has been ascribed to the different reactivity of the target compounds toward Mn(III), which bears striking similarities to recent independent investigations into the use of permanganate as a chemiluminescence reagent. In spite of the importance of Mn(III) in the light-producing pathway, the dependence of the oxidation mechanism for any given compound on this intermediate could not be determined solely through the emission intensity. However, target compounds susceptible to single-electron oxidation by Mn(III) (such as bisphenol A and triclosan) can be easily distinguished by the dramatic increase in chemiluminescence intensity when a permanganate reagent containing high, stable concentrations of Mn(III) is used. The differences are accentuated under the low pH conditions that favor the chemiluminescence emission due to the greater reactivity of Mn(III) and the greater influence of complexing agents. This study supports the previously postulated selective role of ligands and reducing agents in permanganate oxidations and demonstrates a new approach to explore the chemistry of environmental manganese redox processes.

  4. A fluorescent and chemiluminescent difunctional mesoporous silica nanoparticle as a label for the ultrasensitive detection of cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Tao Liang [Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi' an 710062 (China); Song Chaojun; Sun Yuanjie [Department of Immunology, The Fourth Military Medical University, Xi' an 710032 (China); Li Xiaohua; Li Yunyun [Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi' an 710062 (China); Jin Boquan [Department of Immunology, The Fourth Military Medical University, Xi' an 710032 (China); Zhang Zhujun, E-mail: zhangzj@snnu.edu.cn [Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi' an 710062 (China); Yang Kun, E-mail: yangkunkun@fmmu.edu.cn [Department of Immunology, The Fourth Military Medical University, Xi' an 710032 (China)

    2013-01-25

    Highlights: Black-Right-Pointing-Pointer Difunctional amino mesoporous silica nanoparticles (FCMSN) were synthesized. Black-Right-Pointing-Pointer The fluorescence and chemiluminescence properties of the FCMSN were studied. Black-Right-Pointing-Pointer The NaIO{sub 4} oxidation method was used for modification of the FCMSN. Black-Right-Pointing-Pointer Liver cancer 7721 cell was detected. Black-Right-Pointing-Pointer The specificity affected by FCMSN's amino groups was studied. - Abstract: A new kind of ultrabright fluorescent and chemiluminescent difunctional mesoporous silica nanoparticle (FCMSN) is reported. A luminescent dye, Rhodamine 6G or tris(2,2 Prime -bipyridyl)dichlororuthenium(II) hexahydrate (Rubpy), is doped inside nanochannels of a silica matrix. The hydrophobic groups in the silica matrix avoid the leakage of dye from open channels. The amines groups on the surface of the FCMSN improve the modification performance of the nanoparticle. Because the nanochannels are isolated by a network skeleton of silica, fluorescence quenching based on the inner filter effect of the fluorescent dyes immobilized in nanochannels is weakened effectively. The Quantum Yield of obtained 90 nm silica particles was about 61%. Compared with the fluorescent core-shell nanoparticle, the chemiluminescence reagents can freely enter the nanoparticles to react with fluorescent dyes to create chemiluminescence. The results show that the FCMSN are both fluorescent labels and chemiluminescent labels. In biological applications, the NaIO{sub 4} oxidation method was proven to be superior to the glutaraldehyde method. The amount of amino could affect the specificity of the FCMSN. The fluorescence microscopy imaging demonstrated that the FCMSN is viable for biological applications.

  5. Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3

    Directory of Open Access Journals (Sweden)

    Qian-Yun Zhang

    2011-08-01

    Full Text Available Glypican-3 (GPC3 is reported as a great promising tumor marker for hepatocellular carcinoma (HCC diagnosis. Highly sensitive and accurate analysis of serum GPC3 (sGPC3, in combination with or instead of traditional HCC marker alpha-fetoprotein (AFP, is essential for early diagnosis of HCC. Biomaterial-functionalized magnetic particles have been utilized as solid supports with good biological compatibility for sensitive immunoassay. Here, the magnetic nanoparticles (MnPs and magnetic microparticles (MmPs with carboxyl groups were further modified with streptavidin, and applied for the development of chemiluminescence enzyme immunoassay (CLEIA. After comparing between MnPs- and MmPs-based CLEIA, MnPs-based CLEIA was proved to be a better method with less assay time, greater sensitivity, better linearity and longer chemiluminescence platform. MnPs-based CLEIA was applied for detection of sGPC3 in normal liver, hepatocirrhosis, secondary liver cancer and HCC serum samples. The results indicated that sGPC3 was effective in diagnosis of HCC with high performance. Keywords: Magnetic nanoparticle, Magnetic microparticle, Chemiluminescence enzyme immunoassay, Glypican-3, Hepatocellular carcinoma

  6. Tomographic reconstruction of OH* chemiluminescence in two interacting turbulent flames

    International Nuclear Information System (INIS)

    Worth, Nicholas A; Dawson, James R

    2013-01-01

    The tomographic reconstruction of OH* chemiluminescence was performed on two interacting turbulent premixed bluff-body stabilized flames under steady flow conditions and acoustic excitation. These measurements elucidate the complex three-dimensional (3D) vortex–flame interactions which have previously not been accessible. The experiment was performed using a single camera and intensifier, with multiple views acquired by repositioning the camera, permitting calculation of the mean and phase-averaged volumetric OH* distributions. The reconstructed flame structure and phase-averaged dynamics are compared with OH planar laser-induced fluorescence and flame surface density measurements for the first time. The volumetric data revealed that the large-scale vortex–flame structures formed along the shear layers of each flame collide when the two flames meet, resulting in complex 3D flame structures in between the two flames. With a fairly simple experimental setup, it is shown that the tomographic reconstruction of OH* chemiluminescence in forced flames is a powerful tool that can yield important physical insights into large-scale 3D flame dynamics that are important in combustion instability. (paper)

  7. Studies in the reaction dynamics of beam-gas chemiluminescent reactions

    International Nuclear Information System (INIS)

    Prisant, M.G.

    1984-01-01

    This thesis develops techniques for the analysis and interpretation of data obtained from beam-gas chemiluminescence experiments. These techniques are applied to experimental studies of atom transfer reactions of the type A + BC → AB + C. A procedure is developed for determining the product rotational alignment in the center-of-mass frame from polarization measurements of chemiluminescent atom-diatom exchange reactions under beam-gas conditions. Knowledge of a vector property of a reaction, such as product alignment, provides information on the disposition of angular momentum by a chemical reaction. Fluorescence polarization and hence product alignment are measured for two prototype reactions. The reaction of metastable calcium atoms with hydrogen-chloride gas yields highly aligned calcium-chloride product which exhibits little variation of alignment with vibrational state. The reaction of ground-state calcium with fluorine gas yields moderately aligned product which shows strong variation of alignment with vibration. A multi-surface direct-interaction model is developed to interpret product alignment and population data. The predictions of this model for the reaction of calcium with fluorine show reasonable agreement with experiment

  8. Chemiluminescence of curcumin and quenching effect of dimethyl sulfoxide on its peroxyoxalate system

    Energy Technology Data Exchange (ETDEWEB)

    Yari, Abdollah, E-mail: a.yari@ymail.co [Lorestan University, Department of Chemistry, Flakalaflak Street, 68178-17133 Khorramabad (Iran, Islamic Republic of); Saidikhah, Marzieh [Lorestan University, Department of Chemistry, Flakalaflak Street, 68178-17133 Khorramabad (Iran, Islamic Republic of)

    2010-04-15

    The chemiluminescence behavior of the reaction between bis(2,4,6-trichlorophenyl)oxalate (TCPO) and hydrogen peroxide, in the presence of curcumin as fluorophore, has been investigated. Experimental factors such as TCPO, sodium salicylate (SS), hydrogen peroxide and curcumin concentration were optimized. The chemiluminescence signal showed a linear decay while dimethyl sulfoxide (DMSO) was added to the peroxyoxalate (PO-CL) system. The reaction resulted in a Stern-Volmer plot with a K{sub q} value of 7.3x10{sup 4}. The evaluated lower and upper detection limits of measurable concentrations of DMSO are 3.50x10{sup -5} and 1.53x10{sup -4} M, respectively. The PO-CL parameters were estimated by computer fitting of the experimental CL intensity to proper models.

  9. Reagentless chemiluminescence-based fiber optic sensors for regenerative life support in space

    Science.gov (United States)

    Atwater, James E.; Akse, James R.; DeHart, Jeffrey; Wheeler, Richard R., Jr.

    1995-04-01

    The initial feasibility demonstration of a reagentless chemiluminescence based fiber optic sensor technology for use in advanced regenerative life support applications in space and planetary outposts is described. The primary constraints for extraterrestrial deployment of any technology are compatibility with microgravity and hypogravity environments; minimal size, weight, and power consumption; and minimal use of expendables due to the great expense and difficulty inherent to resupply logistics. In the current research, we report the integration of solid state flow through modules for the production of aqueous phase reagents into an integrated system for the detection of important analytes by chemiluminescence, with fiber optic light transmission. By minimizing the need for resupply expendables, the use of solid phase modules makes complex chemical detection schemes practical. For the proof of concept, hydrogen peroxide and glucose were chosen as analytes. The reaction is catalyzed by glucose oxidase, an immobilized enzyme. The aqueous phase chemistry required for sensor operation is implemented using solid phase modules which adjust the pH of the influent stream, catalyze the oxidation of analyte, and provide the controlled addition of the luminophore to the flowing aqueous stream. Precise control of the pH has proven essential for the long-term sustained release of the luminophore. Electrocatalysis is achieved using a controlled potential across gold mesh and gold foil electrodes which undergo periodic polarity reversals. The development and initial characterization of performance of the reagentless fiber optic chemiluminescence sensors are presented in this paper.

  10. Significance of isolated reactive treponemal chemiluminescence immunoassay results.

    Science.gov (United States)

    Hunter, Michael G; Robertson, Peter W; Post, Jeffrey J

    2013-05-01

    Isolated reactive serum treponemal chemiluminescence immunoassay (CIA) specimens cause clinical uncertainty. Sera were screened by CIA, and reactive samples underwent reflex testing with rapid plasma reagin (RPR), Treponema pallidum particle agglutination (TPPA), and fluorescent treponemal antibody absorption (FTA Abs) assays. Samples reactive only on the CIA were deemed "isolated" reactive CIA samples. We undertook detailed review of a subset of subjects with isolated reactive CIA specimens. Of 28 261 specimens, 1171 (4.1%) were reactive on CIA, of which 133 (11.3%) had isolated CIA reactivity. Most subjects (66 of 82 [80.5%]) with isolated reactive CIA specimens were from high-prevalence populations. We found evidence of CIA, TPPA, and FTA Abs seroreversion. The median chemiluminescent signal-to-cutoff ratio was similar for isolated reactive CIA sera and sera that were reactive on either FTA Abs or TPPA assays (2.19 vs 2.32; P = .15) but lower than for sera reactive on both FTA Abs and TPPA assays (12.37; P < .001) or for sera reactive on RPR assays (25.53; P < .001). A total of 11 of 20 patients (55%) with an isolated reactive CIA specimen who underwent medical record review had previous or subsequent evidence of syphilis infection. Isolated reactive CIA specimens may represent true T. pallidum infection and may be found after seroreversion of traditional treponemal assays.

  11. Differentiating between intra- and extracellular chemiluminescence in diluted whole-blood samples

    Czech Academy of Sciences Publication Activity Database

    Rájecký, Michal; Lojek, Antonín; Číž, Milan

    2012-01-01

    Roč. 34, č. 2 (2012), s. 136-142 ISSN 1751-5521 R&D Projects: GA MŠk(CZ) OC10044 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : chemiluminescence * isoluminol * whole blood Subject RIV: BO - Biophysics Impact factor: 1.293, year: 2012

  12. Chitosan oligosaccharides attenuates oxidative-stress related retinal degeneration in rats.

    Directory of Open Access Journals (Sweden)

    I-Mo Fang

    Full Text Available This study investigated the therapeutic potential and mechanisms of chitosan oligosaccharides (COS for oxidative stress-induced retinal diseases. Retinal oxidative damage was induced in Sprague-Dawley rats by intravitreal injection of paraquat (PQ. Low-dose (5 mg/kg or high-dose (10 mg/kg COS or PBS was intragastrically given for 14 days after PQ injection. Electroretinograms were performed to determine the functionality of the retinas. The surviving neurons in the retinal ganglion cell layer and retinal apoptosis were determined by counting Neu N-positive cells in whole-mounted retinas and TUNEL staining, respectively. The generation of reactive oxygen species (ROS was determined by lucigenin- and luminol-enhanced chemiluminescence. Retinal oxidative damages were assessed by staining with nitrotyrosine, acrolein, and 8-hydroxy-2'-deoxyguanosine (8-OHdG. Immunohistochemical studies were used to demonstrate the expression of nuclear factor-kappa B (NF-κB p65 in retinas. An in vitro study using RGC-5 cells was performed to verify the results. We demonstrated COS significantly enhanced the recovery of retinal function, preserved inner retinal thickness, and decreased retinal neurons loss in a dose-dependent manner. COS administration demonstrated anti-oxidative effects by reducing luminol- and lucigenin-dependent chemiluminenscense levels and activating superoxide dismutase and catalase, leading to decreased retinal apoptosis. COS markedly reduced retinal NF-κB p65. An in vitro study demonstrated COS increased IκB expression, attenuated the increase of p65 and thus decreased NF-κB/DNA binding activity in PQ-stimulated RGC-5 cells. In conclusion, COS attenuates oxidative stress-induced retinal damages, probably by decreasing free radicals, maintaining the activities of anti-oxidative enzymes, and inhibiting the activation of NF-κB.

  13. Fingerprint enhancement revisited and the effects of blood enhancement chemicals on subsequent profiler Plus fluorescent short tandem repeat DNA analysis of fresh and aged bloody fingerprints.

    Science.gov (United States)

    Frégeau, C J; Germain, O; Fourney, R M

    2000-03-01

    This study was aimed at determining the effect of seven blood enhancement reagents on the subsequent Profiler Plus fluorescent STR DNA analysis of fresh or aged bloody fingerprints deposited on various porous and nonporous surfaces. Amido Black, Crowle's Double Stain. 1,8-diazafluoren-9-one (DFO), Hungarian Red, leucomalachite green, luminol and ninhydrin were tested on linoleum, glass, metal, wood (pine, painted white), clothing (85% polyester/15% cotton, 65% polyester/35% cotton, and blue denim) and paper (Scott 2-ply and Xerox-grade). Preliminary experiments were designed to determine the optimal blood dilutions to use to ensure a DNA typing result following chemical enhancement. A 1:200 blood dilution deposited on linoleum and enhanced with Crowle's Double Stain generated enough DNA for one to two rounds of Profiler Plus PCR amplification. A comparative study of the DNA yields before and after treatment indicated that the quantity of DNA recovered from bloody fingerprints following enhancement was reduced by a factor of 2 to 12. Such a reduction in the DNA yields could potentially compromise DNA typing analysis in the case of small stains. The blood enhancement chemicals selected were also evaluated for their capability to reveal bloodmarks on the various porous and nonporous surfaces chosen in this study. Luminol. Amido Black and Crowle's Double Stain showed the highest sensitivity of all seven chemicals tested and revealed highly diluted (1:200) bloody fingerprints. Both luminol and Amido Black produced excellent results on both porous and nonporous surfaces, but Crowle's Double Stain failed to produce any results on porous substrates. Hungarian Red, DFO, leucomalachite green and ninhydrin showed lower sensitivities. Enhancement of bloodmarks using any of the chemicals selected, and short-term exposure to these same chemicals (i.e., less than 54 days), had no adverse effects on the PCR amplification of the nine STR systems surveyed (D3S 1358, HumvWA, Hum

  14. Off-line phase-averaged particle image velocimetry and OH chemiluminescence measurements using acoustic time series

    International Nuclear Information System (INIS)

    Fischer, A; Bake, F; Heinze, J; Willert, C; Diers, O; Röhle, I

    2009-01-01

    In order to analyze unsteady flow phenomena in combustion facilities two phase-sorting methods have been developed and investigated for the retrieval of phase-resolved data from (randomly) sampled 'single-shot' data such as PIV recordings or chemiluminescence imagery in a post-processing step. This is made possible by simultaneously recorded continuous time traces of reference data (e.g., pressure signal). Using this off-line method synchronous phase-locked PIV and OH chemiluminescence visualizations could be recovered from data obtained in two different combustion facilities. This paper also presents some of the theoretical background necessary for the application of two different phase-sorting algorithms

  15. Enhanced electrogenerated chemiluminescence of Ru(bpy){sub 3}{sup 2+}/TPrA (bpy=2,2'-bipyridine; TPrA=tri-n-propylamine) via oxygen quenching using melatonin

    Energy Technology Data Exchange (ETDEWEB)

    Witt, Maria D.; Roughton, Sarah; Isakson, Timothy J.; Richter, Mark M., E-mail: markrichter@missouristate.edu

    2016-03-15

    The effect on the electrogenerated chemiluminescence (ECL) of the Ru(bpy){sub 3}{sup 2+}/TPrA (bpy=2,2'-bipyridine; TPra=tri-n-propylamine) system when melatonin (N-acetyl-5-methoxytryptamine; MLT) and structurally related compounds (e.g., D- and L-Tryptophan (TRY), 7-Azatryptophan (7-AZA) and Serotonin (SER)) are present in aqueous buffered solution is reported. MLT, D- and L-TRY, SER and 7-AZA display weak intrinsic ECL when TPrA is used as an oxidative–reductive coreactant. However, micromolar concentrations of melatonin result in up to 2.5-fold enhancement of Ru(bpy){sub 3}{sup 2+}/TPrA ECL while the other analytes attenuate ECL between 2- and 1000-fold. Photoluminescence (PL) emission efficiencies do not change in the presence of melatonin unless the melatonin solution has undergone electrochemical bulk oxidation, at which point PL and ECL are nearly indistinguishable. Spectroscopic, electrochemical and spectroelectrochemical studies indicate that the mechanism involves oxygen scavenging by melatonin oxidation products. This scavenging prevents the quenching of the {sup *}Ru(bpy){sub 3}{sup 2+} excited states by dissolved oxygen in solution. Melatonin can be coupled with 30% by volume 2,2,2-trifluorethanol (TFE) or with the nonionic surfactant Triton X-100 (polyethylene glycol tert-octylphenyl ether) for even greater enhancement of Ru(bpy){sub 3}{sup 2+}/TPrA ECL.

  16. Negative interference by rheumatoid factor in alpha-fetoprotein chemiluminescent microparticle immunoassay.

    Science.gov (United States)

    Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong

    2017-01-01

    Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime

  17. Chemiluminescence from the reaction of Ba 3D with nitric oxide

    International Nuclear Information System (INIS)

    Johnson, S.A.; Solarz, R.W.; Dubrin, J.W.; Brotzmann, R.

    1977-01-01

    The reaction of laser excited Ba*( 3 D) states with nitric oxide is presented. BaO product is not detected, although the channel is thermodynamically open, and instead chemiluminescence is observed. Experiments which suggest that radiative recombination, Ba + NO → BaNO* → BaNO, is the observed reaction channel will also be presented

  18. Radiation effects on chemiluminescence of resting and immunologically activated alveolar macrophages

    International Nuclear Information System (INIS)

    Benichou, G.; Dormont, D.; Herodin, F.; Pasquier, C.; Hopital Saint Antoine, 75 - Paris

    1986-01-01

    In resting cells, for low radiation doses, a transient activation of chemiluminescence was observed, maximal at 3 Gy. At 10 Gy, CL returned to the control value; greater doses (above 30 Gy) induced a progressive diminution of the response which was abolished at 100 Gy. Activated alveolar macrophages showed a 30% decrease of the chemiluminescence at 10 Gy. The respiratory burst induced by opsonized zymosan was abolished at 30 Gy. IgG anti-MHC(IgGαB 1 ) activated specifically the GP S2 alveolar macrophages by alloantibody bipolar bridging; by contrast IgG which are directed against non-specific allogeneic determinants (IgG α B 3 ) or specific F(ab') 2 (F(ab') 2 αB 1 ) are unable to stimulate the cells. For all the tested doses, irradiation had no effect on this activation mechanism. The results with the three doses tested (3 Gy, 10 Gy, 30 Gy) are comparable to those using the positive control cells. The same results are obtained with the class II antigens and their specific IgG. (UK)

  19. β-Orcinol Metabolites from the Lichen Hypotrachyna revoluta

    Directory of Open Access Journals (Sweden)

    Panagiota Papadopoulou

    2007-05-01

    Full Text Available Four new β-orcinol metabolites, hypotrachynic acid (1, deoxystictic acid (2, cryptostictinolide (3 and 8 ́-methylconstictic acid (4 along with the metabolites 8 ́-methylstictic acid (5, 8 ́-methylmenegazziaic acid (6, stictic acid (7, 8 ́-ethylstictic acid (8 and atranorin (9, that have been previously described, were isolated for the first time from the tissue extracts of the lichen Hypotrachyna revoluta (Flörke Hale. The structures of the new metabolites were elucidated on the basis of extensive spectroscopic analyses. Radical scavenging activity (RSA of the metabolites isolated in adequate amounts, was evaluated using luminol chemiluminescence and comparison with Trolox®.

  20. A Novel Technique for Generating and Observing Chemiluminescence in a Biological Setting

    KAUST Repository

    Büchel, Gabriel E.

    2017-03-10

    Intraoperative imaging techniques have the potential to make surgical interventions safer and more effective; for these reasons, such techniques are quickly moving into the operating room. Here, we present a new approach that utilizes a technique not yet explored for intraoperative imaging: chemiluminescent imaging. This method employs a ruthenium-based chemiluminescent reporter along with a custom-built nebulizing system to produce ex vivo or in vivo images with high signal-to-noise ratios. The ruthenium-based reporter produces light following exposure to an aqueous oxidizing solution and re-reduction within the surrounding tissue. This method has allowed us to detect reporter concentrations as low as 6.9 pmol/cm(2). In this work, we present a visual guide to our proof-of-concept in vivo studies involving subdermal and intravenous injections in mice. The results suggest that this technology is a promising candidate for further preclinical research and might ultimately become a useful tool in the operating room.

  1. Molecularly imprinted polymer based on chemiluminescence imaging for the chiral recognition of dansyl-phenylalanine.

    Science.gov (United States)

    Wang, Li; Zhang, Zhujun; Huang, Lianggao

    2008-03-01

    A new molecularly imprinted polymer (MIP)-chemiluminescence (CL) imaging detection approach towards chiral recognition of dansyl-phenylalanine (Phe) is presented. The polymer microspheres were synthesized using precipitation polymerization with dansyl-L-Phe as template. Polymer microspheres were immobilized in microtiter plates (96 wells) using poly(vinyl alcohol) (PVA) as glue. The analyte was selectively adsorbed on the MIP microspheres. After washing, the bound fraction was quantified based on peroxyoxalate chemiluminescence (PO-CL) analysis. In the presence of dansyl-Phe, bis(2,4,6-trichlorophenyl)oxalate (TCPO) reacted with hydrogen peroxide (H2O2) to emit chemiluminescence. The signal was detected and quantified with a highly sensitive cooled charge-coupled device (CCD). Influencing factors were investigated and optimized in detail. Control experiments using capillary electrophoresis showed that there was no significant difference between the proposed method and the control method at a confidence level of 95%. The method can perform 96 independent measurements simultaneously in 30 min and the limits of detection (LODs) for dansyl-L-Phe and dansyl-D-Phe were 0.025 micromol L(-1) and 0.075 micromol L(-1) (3sigma), respectively. The relative standard deviation (RSD) for 11 parallel measurements of dansyl-L-Phe (0.78 micromol L(-1)) was 8%. The results show that MIP-based CL imaging can become a useful analytical technology for quick chiral recognition.

  2. Direct current-induced electrogenerated chemiluminescence of hydrated and chelated Tb(III) at aluminum cathodes

    International Nuclear Information System (INIS)

    Hakansson, M.; Jiang, Q.; Spehar, A.-M.; Suomi, J.; Kotiranta, M.; Kulmala, S.

    2005-01-01

    Cathodic DC polarization of oxide-covered aluminum produces electrogenerated chemiluminescence from hydrated and chelated Tb(III) ions in aqueous electrolyte solutions. At the moment of cathodic voltage onset, a strong cathodic flash is observed, which is attributed to a tunnel emission of hot electrons into the aqueous electrolyte solution and the successive chemical reactions with the luminophores. However, within a few milliseconds the insulating oxide film is damaged and finally dissolved due to (i) indiffusion of protons or alkali metal ions into the thin oxide film, (ii) subsequent hydrogen evolution at the aluminum/oxide interface and (iii) alkalization of the electrode surface induced by hydrogen evolution reaction. When the alkalization of the electrode surface has proceeded sufficiently, chemiluminescence is generated with increasing intensity. Aluminum metal, short-lived Al(II), Al(I) or atomic hydrogen and its conjugated base form, hydrated electron, can act as highly reducing species in addition to the less energetic heterogeneously transferred electrons from the aluminum electrode. Tb(III) added as a hydrated ion in the solution probably luminesces in the form of Tb(OH) 3 or Tb(OH) 4 - by direct redox reactions of the central ion whereas multidentate aromatic ligand chelated Tb(III) probably luminesces by ligand sensitized chemiluminescence mechanism in which ligand is first excited by one-electron redox reactions, which is followed by intramolecular energy transfer to the central ion which finally emits light

  3. Soot and chemiluminescence in diesel combustion of bio-derived, oxygenated and reference fuels

    NARCIS (Netherlands)

    Klein-Douwel, R.J.H.; Donkerbroek, A.J.; Vliet, A.P. van; Boot, M.D.; Somers, L.M.T.; Baert, R.S.G.; Dam, N.J.; Meulen, J.J. ter

    2009-01-01

    High-speed imaging, spectroscopy and thermodynamical characterization are applied to an optically accessible, heavy-duty diesel engine in order to compare sooting and chemiluminescence behaviour of bio-derived, oxygenated fuels and various reference fuels. The fuels concerned include the bio-derived

  4. Development and validation of the first assay method coupling liquid chromatography with chemiluminescence for the simultaneous determination of menadione and its thioether conjugates in rat plasma.

    Science.gov (United States)

    Elgawish, Mohamed Saleh; Shimomai, Chikako; Kishikawa, Naoya; Ohyama, Kaname; Wada, Mitsuhiro; Kuroda, Naotaka

    2013-09-16

    Menadione (2-methyl-1,4-naphthoquinone, MQ), a component of multivitamin drugs with antihemorrhagic, antineoplastic, and antimalarial activity, is frequently used to investigate quinone-induced cytotoxicity. The formation of MQ conjugates with glutathione (GSH) by Michael addition and subsequent biotransformation to yield N-acetyl-l-cysteine conjugates is believed to be an important detoxification process. However, the resulting conjugates, 2-methyl-3-(glutathione-S-yl)-1,4-naphthoquinone (MQ-GS) and 2-methyl-3-(N-acetyl-l-cysteine-S-yl)-1,4-naphthoquinone (MQ-NAC), retain the ability to redox cycle and to arylate cellular nucleophiles. Although the nephrotoxicity and hepatotoxicity of MQ-thiol conjugates have been reported in vitro, methods for their determination in vivo have yet to be published. Herein, a highly sensitive, simple, and selective HPLC-chemiluminescence (HPLC-CL) coupled method is reported, allowing for the first time the simultaneous determination of MQ, MQ-GS, and MQ-NAC in rat plasma after MQ administration. Our method exploits the unique redox characteristics of MQ, MQ-GS, and MQ-NAC to react with dithiothreitol (DTT) to liberate reactive oxygen species (ROS) which are detected by a CL assay using luminol as a CL probe. To verify the proposed mechanism, MQ-GS and MQ-NAC were synthetically prepared. Specimen preparation involved solid-phase extraction on an Oasis HLB cartridge followed by isocratic elution on an ODS column. No interference from endogenous substances was detected. Linearity was observed in the range of 5-120 nM for MQ-GS and MQ-NAC and 10-240 nM for MQ, with detection limits (S/N of 3) of 1.4, 0.8, and 128 fmol for MQ-GS, MQ-NAC, and MQ, respectively. The application of our method reported here is the first to extensively study the stability and reversibility of thiol-quinones.

  5. Detection of γ-irradiation of foods. Use of H2O2-stimulated and photostimulated chemiluminescence. Pt. 1

    International Nuclear Information System (INIS)

    Lewin, G.; Popov, I.N.; Schreiber, G.A.; Helle, N.

    1993-01-01

    Beside methods for unequivocal identification of irradiation treatment of food screening methods which do not always give a final answer are needed for an effective control. In this paper preliminary results are presented which were obtained by measurement of the H 2 O 2 -stimulated and photostimulated chemiluminescence of apples treated by ionising radiation. Appels were chosen as a model for fresh fruit and vegetables. It seems that the H 2 O 2 -stimulated chemiluminescence can be used to screen fruit and vegetables to detect irradiation treatment. (orig.) [de

  6. Phytochemical Characteristics, Free Radical Scavenging Activities, and Neuroprotection of Five Medicinal Plant Extracts

    Directory of Open Access Journals (Sweden)

    Chia Lin Chang

    2012-01-01

    Full Text Available The objective of this study was to determine phytochemical characteristics, chemiluminescence antioxidant capacities, and neuroprotective effects on PC12 cells for methanol extracts of Spatholobus suberectus, Uncaria rhynchophylla, Alpinia officinarum, Drynaria fortunei, and Crataegus pinnatifida. The C. pinnatifida extract (CPE afforded the greatest yield and total phenolic content. The S. suberectus extract (SSE yielded the greatest total flavonoid content. The U. rhynchophylla extract (URE produced the greatest total tannin content, and the A. officinarum extract (AOE produced the greatest total triterpenoid content. The D. fortunei extract, assayed using horseradish peroxidase-luminol-hydrogen peroxide (H2O2, and AOE using pyrogallol-luminol assay each exhibited better antioxidant activity than the L-ascorbic acid and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid did. The CPE, SSE, and URE presented neurogrowth effects and neuroprotective activities on H2O2-induced PC12 cell death at 0.5–5.0 μg/mL. The CPE represents a promising medicinal plant source for the treatment of H2O2-induced neurodegenerative disease, because of its useful phytochemical characteristics.

  7. Phytochemical Characteristics, Free Radical Scavenging Activities, and Neuroprotection of Five Medicinal Plant Extracts

    Science.gov (United States)

    Chang, Chia Lin; Lin, Che San; Lai, Guia Hung

    2012-01-01

    The objective of this study was to determine phytochemical characteristics, chemiluminescence antioxidant capacities, and neuroprotective effects on PC12 cells for methanol extracts of Spatholobus suberectus, Uncaria rhynchophylla, Alpinia officinarum, Drynaria fortunei, and Crataegus pinnatifida. The C. pinnatifida extract (CPE) afforded the greatest yield and total phenolic content. The S. suberectus extract (SSE) yielded the greatest total flavonoid content. The U. rhynchophylla extract (URE) produced the greatest total tannin content, and the A. officinarum extract (AOE) produced the greatest total triterpenoid content. The D. fortunei extract, assayed using horseradish peroxidase-luminol-hydrogen peroxide (H2O2), and AOE using pyrogallol-luminol assay each exhibited better antioxidant activity than the L-ascorbic acid and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid did. The CPE, SSE, and URE presented neurogrowth effects and neuroprotective activities on H2O2-induced PC12 cell death at 0.5–5.0 μg/mL. The CPE represents a promising medicinal plant source for the treatment of H2O2-induced neurodegenerative disease, because of its useful phytochemical characteristics. PMID:21845204

  8. Insights into the ninhydrin chemiluminescent reaction and its potential for micromolar determination of human serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, M. Rodriguez [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Av. Julian Claveria, 8 33006 Oviedo (Spain); Laino, R. Badia [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Av. Julian Claveria, 8 33006 Oviedo (Spain); Diaz-Garcia, M.E. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Av. Julian Claveria, 8 33006 Oviedo (Spain)]. E-mail: medg@uniovi.es

    2006-06-15

    The N-terminal region of human serum albumin (HSA) has an inherent affinity for Co(II) ions. On this basis a new continuous flow method for detection of HSA has been developed taking advantage of the strong quenching effect of the albumin in the ninhydrin-H{sub 2}O{sub 2}-Co(II) chemiluminescent system. The analytical potential of the system is compared with other conventional chemiluminescent reagents. The method gives linear responses from the detection limit (0.30 {mu}M HSA) up to 6.8 {mu}M. The repeatability of the method is good (RSD=7%), it is cheap and rapid to apply and does not require the use of insoluble or expensive reagents nor sophisticated equipment.

  9. Analyzer for measurement of nitrogen oxide concentration by ozone content reduction in gas using solid state chemiluminescent sensor

    Science.gov (United States)

    Chelibanov, V. P.; Ishanin, G. G.; Isaev, L. N.

    2014-05-01

    Role of nitrogen oxide in ambient air is described and analyzed. New method of nitrogen oxide concentration measurement in gas phase is suggested based on ozone concentration measurement with titration by nitrogen oxide. Research of chemiluminescent sensor composition is carried out on experimental stand. The sensor produced on the base of solid state non-activated chemiluminescent composition is applied as ozone sensor. Composition is put on the surface of polymer matrix with developed surface. Sensor compositions includes gallic acid with addition of rodamine-6G. Model of interaction process between sensor composition and ozone has been developed, main products appeared during reaction are identified. The product determining the speed of luminescense appearance is found. This product belongs to quinone class. Then new structure of chemiluminescent composition was suggested, with absence of activation period and with high stability of operation. Experimental model of gas analyzer was constructed and operation algorithm was developed. It was demonstrated that developed NO measuring instrument would be applied for monitoring purposes of ambient air. This work was partially financially supported by Government of Russian Federation, Grant 074-U01

  10. Photoactivation by visible light of CdTe quantum dots for inline generation of reactive oxygen species in an automated multipumping flow system

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, David S.M.; Frigerio, Christian; Santos, Joao L.M. [Requimte, Department of Chemical Sciences, Laboratory of Applied Chemistry, Faculty of Pharmacy, University of Porto, Rua de Jorge Viterbo Ferreira no. 228, 4050-313 Porto (Portugal); Prior, Joao A.V., E-mail: joaoavp@ff.up.pt [Requimte, Department of Chemical Sciences, Laboratory of Applied Chemistry, Faculty of Pharmacy, University of Porto, Rua de Jorge Viterbo Ferreira no. 228, 4050-313 Porto (Portugal)

    2012-07-20

    Highlights: Black-Right-Pointing-Pointer CdTe quantum dots generate free radical species upon exposure to visible radiation. Black-Right-Pointing-Pointer A high power visible LED lamp was used as photoirradiation element. Black-Right-Pointing-Pointer The laboratory-made LED photocatalytic unit was implemented inline in a MPFS. Black-Right-Pointing-Pointer Free radical species oxidize luminol producing a strong chemiluminescence emission. Black-Right-Pointing-Pointer Epinephrine scavenges free radical species quenching chemiluminescence emission. - Abstract: Quantum dots (QD) are semiconductor nanocrystals able to generate free radical species upon exposure to an electromagnetic radiation, usually in the ultraviolet wavelength range. In this work, CdTe QD were used as highly reactive oxygen species (ROS) generators for the control of pharmaceutical formulations containing epinephrine. The developed approach was based on the chemiluminometric monitoring of the quenching effect of epinephrine on the oxidation of luminol by the produced ROS. Due to the relatively low energy band-gap of this chalcogenide a high power visible light emitting diode (LED) lamp was used as photoirradiation element and assembled in a laboratory-made photocatalytic unit. Owing to the very short lifetime of ROS and to ensure both reproducible generation and time-controlled reaction implementation and development, all reactional processes were implemented inline by using an automated multipumping micro-flow system. A linear working range for epinephrine concentration of up to 2.28 Multiplication-Sign 10{sup -6} mol L{sup -1} (r = 0.9953; n = 5) was verified. The determination rate was about 79 determinations per hour and the detection limit was about 8.69 Multiplication-Sign 10{sup -8} mol L{sup -1}. The results obtained in the analysis of epinephrine pharmaceutical formulations by using the proposed methodology were in good agreement with those furnished by the reference procedure, with

  11. Estimation of tritium activity in bioassay samples having chemiluminescence

    International Nuclear Information System (INIS)

    Dwivedi, R.K.; Manu, Kumar; Kumar, Vinay; Soni, Ashish; Kaushik, A.K.; Tiwari, S.K.; Gupta, Ashok

    2008-01-01

    Tritium is recognized as major internal dose contributor in PHWR type of reactors. Estimation of internal dose due to tritium is carried out by analyzing urine samples in liquid scintillation analyzer (LSA). Presence of residual biochemical species in urine samples of some individuals under medical administration shows significant amount of chemiluminescence. If appropriate care is not taken the results obtained by liquid scintillation counter may be mistaken as genuine uptake of tritium. The distillation method described in this paper is used at RAPS-3 and 4 to assess correct tritium uptake. (author)

  12. Flame Structure and Chemiluminescence Emissions of Inverse Diffusion Flames under Sinusoidally Driven Plasma Discharges

    Directory of Open Access Journals (Sweden)

    Maria Grazia De Giorgi

    2017-03-01

    Full Text Available Reduction of nitric oxides (NOx in aircraft engines and in gas turbines by lean combustion is of great interest in the design of novel combustion systems. However, the stabilization of the flame under lean conditions is a main issue. In this context, the present work investigates the effects of sinusoidal dielectric barrier discharge (DBD on a lean inverse diffusive methane/air flame in a Bunsen-type burner under different actuation conditions. The flame appearance was investigated with fixed methane loading (mass flux, but with varying inner airflow rate. High-speed flame imaging was done by using an intensified (charge-coupled device CCD camera equipped with different optical filters in order to selectively record signals from the chemiluminescent species OH*, CH*, or CO2* to evaluate the flame behavior in presence of plasma actuation. The electrical power consumption was less than 33 W. It was evident that the plasma flame enhancement was significantly influenced by the plasma discharges, particularly at high inner airflow rates. The flame structure changes drastically when the dissipated plasma power increases. The flame area decreases due to the enhancement of mixing and chemical reactions that lead to a more anchored flame on the quartz exit with a reduction of the flame length.

  13. A highly sensitive NADH sensor based on a mycelium-like nanocomposite using graphene oxide and multi-walled carbon nanotubes to co-immobilize poly(luminol) and poly(neutral red) hybrid films.

    Science.gov (United States)

    Chiang Lin, Kuo; Yu Lai, Szu; Ming Chen, Shen

    2014-08-21

    Hybridization of poly(luminol) (PLM) and poly(neutral red) (PNR) has been successfully performed and further enhanced by a conductive and steric hybrid nanotemplate using graphene oxide (GO) and multi-walled carbon nanotubes (MWCNTs). The morphology of the PLM-PNR-MWCNT-GO mycelium-like nanocomposite is studied by SEM and AFM and it is found to be electroactive, pH-dependent, and stable in the electrochemical system. It shows electrocatalytic activity towards NADH with a high current response and low overpotential. Using amperometry, it has been shown to have a high sensitivity of 288.9 μA mM(-1) cm(-2) to NADH (Eapp. = +0.1 V). Linearity is estimated in a concentration range of 1.33 × 10(-8) to 1.95 × 10(-4) M with a detection limit of 1.33 × 10(-8) M (S/N = 3). Particularly, it also shows another linear range of 2.08 × 10(-4) to 5.81 × 10(-4) M with a sensitivity of 151.3 μA mM(-1) cm(-2). The hybridization and activity of PLM and PNR can be effectively enhanced by MWCNTs and GO, resulting in an active hybrid nanocomposite for determination of NADH.

  14. Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Yang Zhanjun [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); College of Chemistry and Engineering, Yangzhou University, 88 South University Avenue, Yangzhou 225002 (China); Zong Chen [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Ju Huangxian, E-mail: hxju@nju.edu.cn [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Yan Feng, E-mail: yanfeng2007@sohu.com [Jiangsu Institute of Cancer Prevention and Cure, Nanjing 210009 (China)

    2011-11-07

    Highlights: {yields} A novel capillary immune microreactor was proposed for highly efficient flow-through chemiluminescent immunoassay. {yields} The microreactor was prepared by functionalizing capillary inner wall with streptavidin for capture of biotinylated antibody. {yields} The proposed immunoassay method showed wide dynamic range, good reproducibility, stability and practicality. {yields} The microreactor was low-cost and disposable, and possessed several advantages over the conventional immunoreactors. - Abstract: A streptavidin functionalized capillary immune microreactor was designed for highly efficient flow-through chemiluminescent (CL) immunoassay. The functionalized capillary could be used as both a support for highly efficient immobilization of antibody and a flow cell for flow-through immunoassay. The functionalized inner wall and the capture process were characterized using scanning electron microscopy. Compared to conventional packed tube or thin-layer cell immunoreactor, the proposed microreactor showed remarkable properties such as lower cost, simpler fabrication, better practicality and wider dynamic range for fast CL immunoassay with good reproducibility and stability. Using {alpha}-fetoprotein as model analyte, the highly efficient CL flow-through immunoassay system showed a linear range of 3 orders of magnitude from 0.5 to 200 ng mL{sup -1} and a low detection limit of 0.1 ng mL{sup -1}. The capillary immune microreactor could make up the shortcoming of conventional CL immunoreactors and provided a promising alternative for highly efficient flow-injection immunoassay.

  15. Microspot-based ELISA in microfluidics: chemiluminescence and colorimetry detection using integrated thin-film hydrogenated amorphous silicon photodiodes.

    Science.gov (United States)

    Novo, Pedro; Prazeres, Duarte Miguel França; Chu, Virginia; Conde, João Pedro

    2011-12-07

    Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.

  16. Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index.

    Science.gov (United States)

    Nalewajko-Sieliwoniuk, Edyta; Iwanowicz, Magdalena; Kalinowski, Sławomir; Kojło, Anatol

    2016-03-10

    In this work, we present a novel chemiluminescence (CL) method based on direct-injection detector (DID) integrated with the multi-pumping flow system (MPFS) to chemiluminescence determination of the total polyphenol index. In this flow system, the sample and the reagents are injected directly into the cone-shaped detection cell placed in front of the photomultiplier window. Such construction of the detection chamber allows for fast measurement of the CL signal in stopped-flow conditions immediately after mixing the reagents. The proposed DID-CL-MPFS method is based on the chemiluminescence of nanocolloidal manganese(IV)-hexametaphosphate-ethanol system. The application of ethanol as a sensitizer, eliminated the use of carcinogenic formaldehyde. Under the optimized experimental conditions, the chemiluminescence intensities are proportional to the concentration of gallic acid in the range from 5 to 350 ng mL(-1). The DID-CL-MPFS method offers a number of advantages, including low limit of detection (0.80 ng mL(-1)), high precision (RSD = 3.3%) and high sample throughput (144 samples h(-1)) as well as low consumption of reagents, energy and low waste generation. The proposed method has been successfully applied to determine the total polyphenol index (expressed as gallic acid equivalent) in a variety of plant-derived food samples (wine, tea, coffee, fruit and vegetable juices, herbs, spices). Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

    Science.gov (United States)

    Dunham, A. J.; Barkley, R. M.; Sievers, R. E.; Clarkson, T. W. (Principal Investigator)

    1995-01-01

    An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

  18. l-Tyrosine Contained in Dietary Supplement by Chemiluminescence Reaction of an Iron-Phthalocyanine Complex

    Directory of Open Access Journals (Sweden)

    Takao Ohtomo

    2012-01-01

    Full Text Available The chemiluminescence (CL signal immediately appeared when a hydrogen peroxide solution was injected into an iron-phthalocyanine tetrasulfonic acid (Fe-PTS aqueous solution. Moreover, the CL intensity of Fe-PTS decreased by adding L-tyrosine. Based on these results, the determination of trace amounts of L-tyrosine was developed using the quenching-chemiluminescence. The calibration curve of L-tyrosine was obtained in the concentration range of 2.0×10−7 M to 2.0×10−5 M. Moreover, the relative standard deviation (RSD was 1.63 % (=5 for 2.0×10−6 M L-tyrosine, and its detection limits (3σ were 1.81×10−7 M. The spike and recovery experiments for L-tyrosine were performed using a soft drink. Furthermore, the determination of L-tyrosine was applied to supplements containing various kinds of amino acids. Each satisfactory relative recovery was obtained at 98 to 102%.

  19. Selective Detection of Neurotransmitters by Fluorescence and Chemiluminescence Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ziqiang Wang; Edward S. Yeung

    2001-08-06

    In recent years, luminescence imaging has been widely employed in neurochemical analysis. It has a number of advantages for the study of neuronal and other biological cells: (1) a particular molecular species or cellular constituent can be selectively visualized in the presence of a large excess of other species in a heterogeneous environment; (2) low concentration detection limits can be achieved because of the inherent sensitivity associated with fluorescence and chemiluminescence; (3) low excitation intensities can be used so that long-term observation can be realized while the viability of the specimen is preserved; and (4) excellent spatial resolution can be obtained with the light microscope so subcellular compartments can be identified. With good sensitivity, temporal and spatial resolution, the flux of ions and molecules and the distribution and dynamics of intracellular species can be measured in real time with specific luminescence probes, substrates, or with native fluorescence. A noninvasive detection scheme based on glutamate dehydrogenase (GDH) enzymatic assay combined with microscopy was developed to measure the glutamate release in cultured cells from the central nervous system (CNS). The enzyme reaction is very specific and sensitive. The detection limit with CCD imaging is down to {micro}M levels of glutamate with reasonable response time. They also found that chemiluminescence associated with the ATP-dependent reaction between luciferase and luciferin can be used to image ATP at levels down to 10 nM in the millisecond time scale. Similar imaging experiments should be feasible in a broad spectrum of biological systems.

  20. The synthesis and chemiluminescence of a stable 1,2-dioxetane : an organic chemistry laboratory experiment

    NARCIS (Netherlands)

    Meijer, E.W.; Wynberg, H.

    1982-01-01

    An expt. for the synthesis of adamantylideneadamantane-1,2-dioxetane illustrating the concepts of the singlet O reaction and chemiluminescence, is described. All intermediates and products can be identified by undergraduate students using routine spectroscopic anal. [on SciFinder (R)

  1. Permanganate-bromide-silver nanoparticles as a new chemiluminescence system and its application to captopril determination.

    Science.gov (United States)

    Amjadi, Mohammad; Manzoori, Jamshid L; Hassanzadeh, Javad; Sorouraddin, Mohammad H

    2013-10-15

    A novel chemiluminescence (CL) system based on the oxidation of bromide by permanganate in sulfuric acid medium is introduced. The enhancing effect of silver nanoparticles (NPs), synthesized by chemical reduction method, on this reaction was studied. It was demonstrated that spherical silver nanoparticles with average size of 18 nm had a most remarkable catalytic effect on this reaction. CL emission wavelengths and UV-vis spectra were used to characterize the system and propose a possible mechanism. Furthermore, it was found that captopril inhibits the action of NPs and decreases the intensity of CL. Based on this phenomenon, a new CL method was developed for the determination of captopril in the 3.0 × 10(-10) to 1.0 × 10(-7) mol L(-1) concentration range with a detection limit (3s) of 0.12 nmol L(-1). The method was successfully applied to the determination of captopril in pharmaceutical formulations, human urine and serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Inhibition of chemiluminescence by carvedilol in the cell-free system, whole human blood and blood cells

    Czech Academy of Sciences Publication Activity Database

    Nosál, R.; Jančinová, V.; Číž, Milan; Drábiková, K.; Lojek, Antonín; Fábryová, V.

    2005-01-01

    Roč. 65, č. 1 (2005), s. 55-64 ISSN 0036-5513 Institutional research plan: CEZ:AV0Z50040507 Keywords : blood platelets * carvedilol * chemiluminescence Subject RIV: BO - Biophysics Impact factor: 0.946, year: 2005

  3. Flow injection chemiluminescence determination of lercanidipine based on N-chlorosuccinimide-eosin Y post-chemiluminescence reaction.

    Science.gov (United States)

    Wang, Guowei; Zhao, Fang; Gao, Ying

    2014-12-01

    A novel post-chemiluminescence (PCL) reaction was discovered when lercanidipine was injected into the CL reaction mixture of N-chlorosuccinimide with alkaline eosin Y in the presence of cetyltrimethylammonium bromide (CTAB), where eosin Y was used as the CL reagent and CTAB as the surfactant. Based on this observation, a simple and highly sensitive PCL method combined with a flow injection (FI) technique was developed for the assay of lercanidipine. Under optimum conditions, the CL signal was linearly related to the concentration of lercanidipine in the range 7.0 × 10(-10) to 3.0 × 10(-6)  g/mL with a detection limit of 2.3 × 10(-10) g/mL (3σ). The relative standard deviation (RSD) was 2.1% for 1.0 × 10(-8) g/mL lercanidipine (n = 13). The proposed method had been applied to the estimation of lercanidipine in tablets and human serum samples with satisfactory results. The possible CL mechanism is also discussed briefly. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Determination of vitamin C in drugs using of an optimized novel TCPO–Amplex red–gold/silver alloy nanoparticles–H2O2 chemiluminescence method by the Box–Behnken design

    International Nuclear Information System (INIS)

    Chaichi, M.J.; Alijanpour, S.O.

    2013-01-01

    Response surface methodology (RSM), based on a Box–Behnken design (BBD) was used to optimize three of the most important operating variables (concentrations of TCPO, Amplex red and pH effect) at peroxyoxalate-chemiluminescence (PO-CL) system. For the first time Amplex red (AR) was introduced as a new fluorescent emitter for predicting the reaction mechanism of PO-CL by means of the fluorescence property of its oxidation product. In optimum conditions, it was found that Au/Ag alloy nanoparticles (NPs) could enhance the CL intensity and the method sensitivity toward the evaluation of trace amount of vitamin C. Based on the antioxidant property of vitamin C noticeably the CL signal of the bis-(2,4,6-trichlorophenyl)oxalate–AR–NPs–hydrogen peroxide–sodium salicylate system was quenched in a low basic medium. A simple, rapid and sensitive CL method for the determination of vitamin C has been developed. The results showed a linear relationship between vitamin C concentration and PO-CL intensity in the range of 0.082–82.7 μg/mL. Detection limit of 0.012 μg/mL and the relative standard deviation (RSD)<4% was obtained. - Highlights: ► The Box-Behnken design was used to optimize peroxyoxalate-chemiluminescence system. ► Amplex red is as new fluorescent emitters for peroxyoxalate chemiluminescence. ► It is introduce a method for determination of vitamin C. ► Detection limit of vitamin C was obtained about 0.012 μg/mL.

  5. Combustion stratification study of partially premixed combustion using Fourier transform analysis of OH* chemiluminescence images

    KAUST Repository

    Izadi Najafabadi, Mohammad

    2017-11-06

    A relatively high level of stratification (qualitatively: lack of homogeneity) is one of the main advantages of partially premixed combustion over the homogeneous charge compression ignition concept. Stratification can smooth the heat release rate and improve the controllability of combustion. In order to compare stratification levels of different partially premixed combustion strategies or other combustion concepts, an objective and meaningful definition of “stratification level” is required. Such a definition is currently lacking; qualitative/quantitative definitions in the literature cannot properly distinguish various levels of stratification. The main purpose of this study is to objectively define combustion stratification (not to be confused with fuel stratification) based on high-speed OH* chemiluminescence imaging, which is assumed to provide spatial information regarding heat release. Stratification essentially being equivalent to spatial structure, we base our definition on two-dimensional Fourier transforms of photographs of OH* chemiluminescence. A light-duty optical diesel engine has been used to perform the OH* bandpass imaging on. Four experimental points are evaluated, with injection timings in the homogeneous regime as well as in the stratified partially premixed combustion regime. Two-dimensional Fourier transforms translate these chemiluminescence images into a range of spatial frequencies. The frequency information is used to define combustion stratification, using a novel normalization procedure. The results indicate that this new definition, based on Fourier analysis of OH* bandpass images, overcomes the drawbacks of previous definitions used in the literature and is a promising method to compare the level of combustion stratification between different experiments.

  6. Label-free genotyping of cytochrome P450 2D6*10 using ligation-mediated strand displacement amplification with DNAzyme-based chemiluminescence detection.

    Science.gov (United States)

    Wang, Hong-Qi; Wu, Zhan; Zhang, Yan; Tang, Li-Juan; Yu, Ru-Qin; Jiang, Jian-Hui

    2012-01-13

    Genotyping of cytochrome P450 monooxygenase 2D6*10 (CYP2D6*10) plays an important role in pharmacogenomics, especially in clinical drug therapy of Asian populations. This work reported a novel label-free technique for genotyping of CYP2D6*10 based on ligation-mediated strand displacement amplification (SDA) with DNAzyme-based chemiluminescence detection. Discrimination of single-base mismatch is firstly accomplished using DNA ligase to generate a ligation product. The ligated product then initiates a SDA reaction to produce aptamer sequences against hemin, which can be probed by chemiluminescence detection. The proposed strategy is used for the assay of CYP2D6*10 target and the genomic DNA. The results reveal that the proposed technique displays chemiluminescence responses in linear correlation to the concentrations of DNA target within the range from 1 pM to 1 nM. A detection limit of 0.1 pM and a signal-to-background ratio of 57 are achieved. Besides such high sensitivity, the proposed CYP2D6*10 genotyping strategy also offers superb selectivity, great robustness, low cost and simplified operations due to its label-free, homogeneous, and chemiluminescence-based detection format. These advantages suggest this technique may hold considerable potential for clinical CYP2D6*10 genotyping and association studies. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. A simple and sensitive immunoassay for the determination of human chorionic gonadotropin by graphene-based chemiluminescence resonance energy transfer.

    Science.gov (United States)

    Lei, Jiuqian; Jing, Tao; Zhou, Tingting; Zhou, Yusun; Wu, Wei; Mei, Surong; Zhou, Yikai

    2014-04-15

    In this study, we report a strategy of chemiluminescence resonance energy transfer (CRET) using graphene as an efficient long-range energy acceptor. Magnetic nanoparticles were also used in CRET for simple magnetic separation and immobilization of horseradish peroxidase (HRP)-labeled anti-HCG antibody. In the design of CRET system, the sandwich-type immunocomplex was formed between human chorionic gonadotropin (HCG, antigen) and two different antibodies bridged the magnetic nanoparticles and graphene (acceptors), which led to the occurrence of CRET from chemiluminescence light source to graphene. After optimizing the experimental conditions, the quenching of chemiluminescence signal depended linearly on the concentration of HCG in the range of 0.1 mIU mL(-1)-10 mIU mL(-1) and the detection limit was 0.06 mIU mL(-1). The proposed method was successfully applied for the determination of HCG levels in saliva and serum samples, and the results were in good agreement with the plate ELISA with colorimetric detection. It could also be developed for detection of other antigen-antibody immune complexes by using the corresponding antigens and respective antibodies. © 2013 Published by Elsevier B.V.

  8. Evaluation and Comparison of Chemiluminescence and UV Photometric Methods for Measuring Ozone Concentrations in Ambient Air

    Science.gov (United States)

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O3) that may be p...

  9. Radiosensitivity of the developing central nervous system: an important question in radiation protection

    International Nuclear Information System (INIS)

    Perez, Maria del R.; Gisone, Pablo A.; Dubner, Diana L.; Robello, Elizabeth; Michelin, Severino C.

    2004-01-01

    The high radiosensitivity of the human developing brain has been demonstrated by epidemiological data . The maximal incidence of microcephaly and mental retardation in the Hiroshima and Nagasaki cohort was observed among survivors exposed between 8 and 15 weeks of gestation. Experimental studies indicate that this period corresponds to gestational days (g.d.) 14-18 in the rat. Apoptosis, the typical mode of radiation-induced cell death in developing Central Nervous System (CNS), is closely related with the oxidative status. Enhanced radiation-induced generation of reactive oxygen and nitrogen species (ROS/RNS) has been observed after low-dose radiation exposure, leading to the amplification of signal transduction and further molecular and cellular radiation-responses. This study is an attempt to address the participation of ROS/RNS in the early radiation-induced apoptosis of neural cortical precursors. Cortical cells obtained from Wistar rat fetuses at 17 g.d. were irradiated with a dose of 2 Gy at a dose-rate of 0.3 Gy/minute. Nitric oxide (NO) content estimated by measuring the stable products NO 2 and NO 3 released to the culture medium, has shown a time-dependent accumulation from 30 min post-irradiation (pi). ROS/RNS content was determined by luminol-dependent chemiluminescence. A significant decrease of chemiluminescence was evident 30 min pi, reaching basal levels at 120 min, followed by an important augmentation by 4 hs after irradiation. The early decrease in ROS/RNS was not observed in samples irradiated in the presence of L-NAME, an inhibitor of nitric oxide synthase. Incubations with superoxide dismutase (SOD) and catalase (CAT) decreased significantly the chemiluminescence in irradiated samples. Apoptotic cell death, already evident from 4 hs pi., was significantly increased in irradiated cells after incubation with L-NAME. We conclude that ROS/RNS play a pivotal role in the early signaling pathway leading to a radiation-induced cell death of cortical

  10. Tape Cassette Bacteria Detection System

    Science.gov (United States)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  11. Determination of thiram in natural waters using flow-injection with cerium(IV)-quinine chemiluminescence system.

    Science.gov (United States)

    Waseem, Amir; Yaqoob, Mohammad; Nabi, Abdul

    2010-01-01

    A simple and rapid flow-injection chemiluminescence method has been developed for the determination of dithiocarbamate fungicide thiram based on the chemiluminescence reaction of thiram with ceric sulfate and quinine in aqueous sulfuric acid. The present method allowed the determination of thiram in the concentration range of 7.5-2500 ng/mL and the detection limit (signal-to-noise ratio = 3) was 7.5 ng/mL with sample throughput of 120/h. The relative standard deviation was 2.5% for 10 replicate analyses of 500 ng/mL thiram. The effects of foreign species including various anions and cations present in water at environmentally relevant concentrations and some pesticides were also investigated. The proposed method was applied to determine thiram in spiked natural waters using octadecyl bonded phase silica (C(18)) cartridges for solid-phase extraction. The recoveries were in the range 99 +/- 1 to 104 +/- 1%. Copyright (c) 2009 John Wiley & Sons, Ltd.

  12. Flow-injection chemiluminescent determination of estrogen benzoate using the tris(1,10-phenanthroline) ruthenium(II)-permanganate system.

    Science.gov (United States)

    Ma, Yan; Cao, Wei; Qiao, Shuang; Liu, Wenwen; Yang, Jinghe

    2011-01-01

    Chemiluminescence (CL) detection for the determination of estrogen benzoate, using the reaction of tris(1,10-phenanthroline)ruthenium(II)-Na(2)SO(3)-permanganate, is described. This method is based on the CL reaction of estrogen benzoate (EB) with acidic potassium permanganate and tris(1,10-phenanthroline)ruthenium(II). The CL intensity is greatly enhanced when Na(2)SO(3) is added. After optimization of the different experimental parameters, a calibration graph for estrogen benzoate is linear in the range 0.05-10 µg/mL. The 3 s limit of detection is 0.024 µg/mL and the relative standard deviation was 1.3% for 1.0 µg/mL estrogen benzoate (n = 11). This proposed method was successfully applied to commercial injection samples and emulsion cosmetics. The mechanism of CL reaction was also studied. Copyright © 2011 John Wiley & Sons, Ltd.

  13. Electrospun Poly(L-Lactide-co-ε-Caprolactone/Polyethylene Oxide/Hydroxyapaite Nanofibrous Membrane for Guided Bone Regeneration

    Directory of Open Access Journals (Sweden)

    Gang Wang

    2010-01-01

    Full Text Available A series of poly(L-lactide-co-ε-caprolactone/polyethylene oxide/hydroxyapaite (PLCL/PEO/HA composite fibrous membranes were prepared by elecrospinning technology for guided bone regeneration. The morphology, water permeability and mechanical properties of the membranes were investigated. The HA nanocrystals can be well distributed in the PLCL/PEO matrix. And the diameter of composite nanofiber is larger than that of pure PLCL. The fibers with uniform size and large diameter were obtained when the contents of PEO and HA were 0.4% and 0.03%, respectively. In this condition, the obtained membrane presents the best water permeability. Furthermore, the nanofibrous membrane with largest tensile strength was obtained when the contents of PEO and HA were 0.5% and 0.03%, respectively.

  14. Ester oxidation on an aluminum surface using chemiluminescence

    Science.gov (United States)

    Jones, William R., Jr.; Meador, Michael A.; Morales, Wilfredo

    1986-01-01

    The oxidation characteristics of a pure ester (trimethyolpropane triheptanoate) were studied by using a chemiluminescence technique. Tests were run in a thin film microoxidation apparatus with an aluminum alloy catalyst. Conditions included a pure oxygen atmosphere and a temperature range of 176 to 206 C. Results indicated that oxidation of the ester (containing .001 M diphenylanthracene as an intensifier) was accompanied by emission of light. The maximum intensity of light emission was a function of the amount of ester, the concentration of intensifier, and the test temperature. The induction period, or the time to reach one-half of maximum intensity was inversely proportional to test temperature. Decreases in light emission at the later stages of a test were caused by depletion of the intensifier.

  15. Cathodic electrogenerated chemiluminescence of aromatic Tb(III) chelates at polystyrene-graphite composite electrodes

    International Nuclear Information System (INIS)

    Salminen, Kalle; Grönroos, Päivi; Tuomi, Sami; Kulmala, Sakari

    2017-01-01

    Tb(III) chelates exhibit intense hot electron-induced electrogenerated chemiluminescence during cathodic polarization of metal/polystyrene-graphite (M/PG) electrodes in fully aqueous solutions. The M/PG working electrode provides a sensitive means for the determination of aromatic Tb(III) chelates at nanomolar concentration levels with a linear log-log calibration curve spanning more than five orders of magnitude. The charge transport and other properties of these novel electrodes were studied by electrochemiluminescence measurements and cyclic voltammetry. The present composite electrodes can by utilized both under pulse polarization and DC polarization unlike oxide-coated metal electrodes which do not tolerate cathodic DC polarization. The present cost-effective electrodes could be utilized e.g. in immunoassays where polystyrene is extensively used as a solid phase for various bioaffinity assays by using electrochemiluminescent Tb(III) chelates or e.g. Ru(bpy) 3 2+ as labels. - Highlights: • Generation of hydrated electrons at Polystyrene-graphite electrodes. • The insulating polystyrene layer on the outer electrode surface seems necessary. • Hydrated electrons are able to produce chemiluminescence. • Strongest signal and lowest std. dev. achieved at same graphite weight fraction.

  16. Luminol-based electrochemiluminescent biosensors for highly sensitive medical diagnosis and rapid antioxidant detection

    Science.gov (United States)

    Tamiya, Eiichi; Inoue, Yuki; Saito, Masato

    2018-03-01

    We present a review of luminol-based electrochemiluminescence (ECL) biosensors that perform enzymatic reactions and bioanalysis using antioxidant molecules by controlling the spatiotemporal production of a luminescent substrate, catalase activity, and glycated albumin (GA). The ECL intensity depends on the antioxidant capacity because radicals are neutralized by the antioxidants, which suppresses the luminescence. The antioxidant capacities of 22 types beverages were evaluated by comparison with a standard curve of Trolox. The time necessary for the ECL measurement of the antioxidant capacity is only 2 min with screen-printed electrodes and a portable ECL measurement system. Our system was also used to monitor reactive oxygen species released from neutrophils, which play an important role in the immune system, defending against viral and bacterial infections. The quenching of ECL imaging by catalase reaction localized in the multichamber electrode using the electrogenerated substrate was examined as a potential candidate for a sensitive reporting system. The substrate was successfully generated at applied potentials between -1 and -0.4 V in multichamber electrodes and the substrate confinement within the chamber was observed within 60 s of generation. The microchamber electrode system demonstrated a detection limit of 90 fM catalase. We also demonstrated a detection limit of 0.1 µM GA in human serum albumin, which is an improvement of about 70 times over colorimetric methods.

  17. Anti-inflammatory activity of 3-thiazolyl coumarins

    International Nuclear Information System (INIS)

    Salar, U.; Khan, M.; Bakhtawar, A.; Kanwal, A.; Jabeen, A.; Faheem, A.

    2017-01-01

    3-Thiazolyl coumarins 1-33 along with coumarin scaffold (IC50 = 5.2 +- 0.2 mu g/mL) were evaluated for in vitro antiinflammatory activity. Activity of compounds was investigated by looking their influence on oxidative burst activity of zymosan stimulated whole blood phagocytes by using a luminol enhanced chemiluminescence technique. Ibuprofen was used as standard drug (IC50 = 54.2 +- 9.2 mu M). Four 3-thiazolyl coumarin derivatives 9 (IC50 = 31.0 +- 2.5 mu g/mL), 13 (IC50 = 27.1 +- 4.2 mu g/mL), 18 (IC50 = 5.6 +- 2.6 mu g/mL), and 29 (IC50 = 1.9 +- 1.0 mu g/mL) out of thirty-three demonstrated antiinflammatory activity as compared to the standard ibuprofen (IC50 = 11.2 +- 1.9 mu g/mL). Especially, compound 29 showed many folds better activity as compared to coumarin and standard ibuprofen. Structure-activity relationship was also established. It is worth-mentioning that active analogs 9, 13, 18, and 29 were found to be non-toxic on NIH-3T3 mouse fibroblast cell line. (author)

  18. Determination of vitamin C in drugs using of an optimized novel TCPO-Amplex red-gold/silver alloy nanoparticles-H{sub 2}O{sub 2} chemiluminescence method by the Box-Behnken design

    Energy Technology Data Exchange (ETDEWEB)

    Chaichi, M.J., E-mail: jchaichi@yahoo.com [Faculty of Chemistry, University of Mazandaran, Babolsar (Iran, Islamic Republic of); Alijanpour, S.O. [Faculty of Chemistry, University of Mazandaran, Babolsar (Iran, Islamic Republic of)

    2013-02-15

    Response surface methodology (RSM), based on a Box-Behnken design (BBD) was used to optimize three of the most important operating variables (concentrations of TCPO, Amplex red and pH effect) at peroxyoxalate-chemiluminescence (PO-CL) system. For the first time Amplex red (AR) was introduced as a new fluorescent emitter for predicting the reaction mechanism of PO-CL by means of the fluorescence property of its oxidation product. In optimum conditions, it was found that Au/Ag alloy nanoparticles (NPs) could enhance the CL intensity and the method sensitivity toward the evaluation of trace amount of vitamin C. Based on the antioxidant property of vitamin C noticeably the CL signal of the bis-(2,4,6-trichlorophenyl)oxalate-AR-NPs-hydrogen peroxide-sodium salicylate system was quenched in a low basic medium. A simple, rapid and sensitive CL method for the determination of vitamin C has been developed. The results showed a linear relationship between vitamin C concentration and PO-CL intensity in the range of 0.082-82.7 {mu}g/mL. Detection limit of 0.012 {mu}g/mL and the relative standard deviation (RSD)<4% was obtained. - Highlights: Black-Right-Pointing-Pointer The Box-Behnken design was used to optimize peroxyoxalate-chemiluminescence system. Black-Right-Pointing-Pointer Amplex red is as new fluorescent emitters for peroxyoxalate chemiluminescence. Black-Right-Pointing-Pointer It is introduce a method for determination of vitamin C. Black-Right-Pointing-Pointer Detection limit of vitamin C was obtained about 0.012 {mu}g/mL.

  19. Sensitive chemiluminescence immunoassay for staphylococcal enterotoxin C1 based on the use of dye-encapsulated mesoporous silica nanoparticles

    International Nuclear Information System (INIS)

    Tao, Liang; Zhang, Chunmei; Sun, Yuanjie; Jin, Boquan; Yang, Kun; Li, Xiaohua; Zhang, Zhujun; Zhang, Jinpeng; Yan, Kuocheng

    2016-01-01

    A chemiluminescent immunoassay for the staphylococcal enterotoxin C1 (SEC1) based on the use of dye-encapsulated mesoporous silica nanoparticles (m-SiNPs) as a label is described. The dyes are retained in the m-SiNPs via strong hydrophobic interactions. The assay comprises the following steps: (a) Microplates coated with antibody against SEC1 are filled with sample upon which the SEC antigen will be bound to the surface; (b) following a washing step, secondary antibody linked to m-SiNPs (that were covalently labeled with rhodamine 6G and fluorescein) were added to form the sandwich complex; (c) after another washing step, bis(2,4,6-trichlorophenyl) oxalate, H_2O_2 and imidazole are added to generate chemiluminescence whose intensity is proportional to the number of m-SiNPs and thus to the number of antigen (SEC) molecules. It is found that the use of functionalized m-SiNPs strongly amplifies the signal. Enterotoxin SEC1 can be detected by this method in the 0.025 to 2 ng⋅mL"-"1 concentration range, the detection limit is 19 pg⋅mL"-"1 (at 3σ), and the relative standard deviation (for 11 parallel measurements at a 1 ng⋅mL"-"1 level) is 4.6 %. The use of an automated chemiluminescence analyzer further improves detection. (author)

  20. Fabrication and preliminary study of a biomimetic tri-layer tubular graft based on fibers and fiber yarns for vascular tissue engineering.

    Science.gov (United States)

    Wu, Tong; Zhang, Jialing; Wang, Yuanfei; Li, Dandan; Sun, Binbin; El-Hamshary, Hany; Yin, Meng; Mo, Xiumei

    2018-01-01

    Designing a biomimetic and functional tissue-engineered vascular graft has been urgently needed for repairing and regenerating defected vascular tissues. Utilizing a multi-layered vascular scaffold is commonly considered an effective way, because multi-layered scaffolds can easily simulate the structure and function of natural blood vessels. Herein, we developed a novel tri-layer tubular graft consisted of Poly(L-lactide-co-caprolactone)/collagen (PLCL/COL) fibers and Poly(lactide-co-glycolide)/silk fibroin (PLGA/SF) yarns via a three-step electrospinning method. The tri-layer vascular graft consisted of PLCL/COL aligned fibers in inner layer, PLGA/SF yarns in middle layer, and PLCL/COL random fibers in outer layer. Each layer possessed tensile mechanical strength and elongation, and the entire tubular structure provided tensile and compressive supports. Furthermore, the human umbilical vein endothelial cells (HUVECs) and smooth muscle cells (SMCs) proliferated well on the materials. Fluorescence staining images demonstrated that the axially aligned PLCL/COL fibers prearranged endothelium morphology in lumen and the circumferential oriented PLGA/SF yarns regulated SMCs organization along the single yarns. The outside PLCL/COL random fibers performed as the fixed layer to hold the entire tubular structure. The in vivo results showed that the tri-layer vascular graft supported cell infiltration, scaffold biodegradation and abundant collagen production after subcutaneous implantation for 10weeks, revealing the optimal biocompatibility and tissue regenerative capability of the tri-layer graft. Therefore, the specially designed tri-layer vascular graft will be beneficial to vascular reconstruction. Copyright © 2017. Published by Elsevier B.V.

  1. Application of UV-Vis spectrophotometric and chemiluminescent methods for the evaluation of the antioxidant action of curcumin

    Czech Academy of Sciences Publication Activity Database

    Stanchev, Stancho; Pencheva, I.; Konstantinov, S.; Obreshkova, D.; Hadjimitova, V.

    2012-01-01

    Roč. 77, č. 8 (2012), s. 1063-1069 ISSN 0352-5139 Institutional research plan: CEZ:AV0Z40550506 Keywords : curcumin * antioxidant * UV-Vis spectrophotometry * DNA complexation * chemiluminescence Subject RIV: CC - Organic Chemistry Impact factor: 0.912, year: 2012

  2. An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads.

    Science.gov (United States)

    Tao, Xiaoqi; Jiang, Haiyang; Yu, Xuezhi; Zhu, Jinghui; Wang, Xia; Wang, Zhanhui; Niu, Lanlan; Wu, Xiaoping; Shen, Jianzhong

    2013-05-01

    A competitive, direct, chemiluminescent immunoassay based on a magnetic beads (MBs) separation and gold nanoparticles (AuNPs) labelling technique to detect chloramphenicol (CAP) has been developed. Horseradish peroxidase (HRP)-labelled anti-CAP monoclonal antibody conjugated with AuNPs and antigen-immobilized MBs were prepared. After optimization parameters of immunocomplex MBs, the IC50 values of chemiluminescence magnetic nanoparticles immunoassay (CL-MBs-nano-immunoassay) were 0.017 µg L(-1) for extract method I and 0.17 µg L(-1) for extract method II. The immunoassay with two extract methods was applied to detect CAP in milk. Comparison of these two extract methods showed that extract method I was advantageous in better sensitivity, in which the sensitivity was 10 times compared to that of extract method II, while extract method II was superior in simple operation, suitable for high throughout screen. The recoveries were 86.7-98.0% (extract method I) and 80.0-103.0% (extract method II), and the coefficients of variation (CVs) were all recovery with both extract methods and high correlation with traditional ELISA kit in milk system confirmed that the immunomagnetic assay based on AuNPs exhibited promising potential in rapid field screening for trace CAP analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  3. Chemiluminescence ELISA for the detection of oxidative DNA base damage using anti-8-hydroxy-2'-deoxyguanosine antibody. Application to the detection of irradiated foods

    International Nuclear Information System (INIS)

    Kikuchi, Masahiro; Funayama, Tomoo; Sakashita, Tetsuya; Satoh, Katsuya; Narumi, Issay; Kobayashi, Yashihiko; Gunawardane, Chaminda R.; Alam, Md. Khorshed; Dzomir, A. Zainuri Mohd.; Pitipanaarachchi, Ramya C.; Hamada, Nobuyuki; Wada, Seiichi

    2007-01-01

    Since ionizing radiation is used for sterilizing or lowering the microbial content of foods as a means of reducing food losses and securing food safety, the development of versatile detection methods of irradiated foods is necessary for appropriate management. In an effort to distinguish between irradiated and non-irradiated food, a method based on the detection of oxidative DNA base damage using the chemiluminescence enzyme-linked immunosorbent assay (ELISA) with anti-8-hydroxy-2'-deoxyguanosine antibody was developed. In the course of optimizing the reaction conditions for the ELISA, a 30-mer synthetic oligonucleotide containing 8-hydroxyguanine (8-oxoG) was used. Under the optimized conditions, the correlation between chemiluminescence intensity and 8-oxoG content in oligonucleotides was obtained. It was shown that this chemiluminescence ELISA method could be applied to chicken, beef and pork that were irradiated with over 3 kGy. Twenty milligrams of a loaf of meat was sufficient to distinguish between irradiated and non-irradiated meat by this method. (author)

  4. Measurements of essential oil extract and antioxidant in Syrian Myrtus communis L. leaves using photo chemiluminescence assay

    International Nuclear Information System (INIS)

    Zayzafoon, G.; Odeh, A.; Mahzia, Y.

    2012-01-01

    The essential oil extracts and antioxidant measurements of Syrian Myrtus communis L. leaves as hydrophilic and hydrophobic existence species have been carried out. The plant leaves as a source of antioxidants was tested by the influence of its aqueous and essential oil extracts on the yield of photo chemiluminescence, PCL solution applying very sensitive and reliable method. By means of a photo chemiluminescence assay, it was possible to assess the total antioxidants capacity of hydrophilic and hydrophobic species existence in Syrian Myrtus communis L. leaves. It has been found that, the integral antioxidant capacity measurements value of Syrian Myrtus communis L. leaves was found in Kurdaha site which has a value of 465.67 1.18 nmol TE/g DM (total Trolox equivalent /gram of Dry material) . The following three mainly chemical species were found in the essential oil extracts: -Pinene, Cineole and Limonene. (author)

  5. Application of Box–Behnken design in the optimization of new peroxyoxalate–H2O2 chemiluminescence system using furan derivatives as blue activators

    International Nuclear Information System (INIS)

    Chaichi, M.J.; Azizi, S.N.; Alijanpour, O.; Heidarpour, M.; Qandalee, M.

    2013-01-01

    The non-commercially synthesized and purified furan derivatives are of great interest as fluorescent emitters for peroxyoxalate chemiluminescence (PO-CL). The reaction of oxalic ester such as bis-(2,4,6-trichloro-phenyl) oxalate (TCPO) with H 2 O 2 can lead to the excitation of an appropriate activator via the formation of a 1,2-dioxetanedione intermediate. In this study, two furan derivatives were used as activators which produce a blue light in the chemiluminescence systems. In the following, the Box–Behnken design matrix and response surface methodology (RSM) have been applied to design the experiments to study the relationship between the chemiluminescence intensities and the three most important operating variables such as sodium salicylate (5×10 −4 –5×10 −3 M), furan (10 −5 –10 −3 M) and hydrogen peroxide (10 −3 –10 −1 M) concentrations, and also to evaluate the interactive effects of these variables on the CL emission of TCPO system. Totally 15 experiments were conducted in the present study towards the construction of a quadratic model. Independent variables of sodium salicylate, hydrogen peroxide and furan concentration have the significance value of p=0.05, in both the systems, which explicitly shows the importance of these variables in the CL emission of TCPO. Values of Prob>F less than 0.0001 indicated that the model terms are significant for the CL emission of TCPO. Moreover, the regression equation coefficients were calculated and the data fitted to a second-order polynomial equation for CL emission of TCPO. -- Highlights: ► Furan derivatives are used as activators for peroxyoxalate chemiluminescence. ► The activators produce a blue light in the chemiluminescence system. ► The Box–Behnken design matrix and response surface methodology (RSM) is used. ► The most important variables are sodium salicylate, furan and hydrogen peroxide. ► The data are fitted to a second-order polynomial equation for CL emission of TCPO

  6. Simplex optimization of the variables influencing the determination of pefloxacin by time-resolved chemiluminescence

    Science.gov (United States)

    Murillo Pulgarín, José A.; Alañón Molina, Aurelia; Jiménez García, Elisa

    2018-03-01

    A new chemiluminescence (CL) detection system combined with flow injection analysis (FIA) for the determination of Pefloxacin is proposed. The determination is based on an energy transfer from Pefloxacin to terbium (III). The metal ion enhances the weak CL signal produced by the KMnO4/H2SO3/Pefloxacin system. A modified simplex method was used to optimize chemical and instrumental variables. The influence of the interaction of the permanganate, Tb (III), sodium sulphite and sulphuric acid concentrations, flow rate and injected sample volume was thoroughly investigated by using a modified simplex optimization procedure. The results revealed a strong direct relationship between flow rate and CL intensity throughout the studied range that was confirmed by a gamma test. The response factor for the CL emission intensity was used to assess performance in order to identify the optimum conditions for maximization of the response. Under such conditions, the CL response was proportional to the Pefloxacin concentration over a wide range. The detection limit as calculated according to Clayton's criterion 13.7 μg L- 1. The analyte was successfully determined in milk samples with an average recovery of 100.6 ± 9.8%.

  7. The application of automatic chemiluminescence machine in rapid immune detection

    International Nuclear Information System (INIS)

    Lin Aizhen; Li Xuanwei; Chen Binhong; Li Zhenqian; Chen Zhaoxuan

    2004-01-01

    Objective: To provide high-quality, rapid and dependable result for clinical practice, and give satisfactory service to patients of different economical status by supplementation with other labeling immune examination. With an innovative attitude, we carried out efficient technical reform on ACS180 automatic chemiluminescence machine, making it possible for patients to complete the whole process including examination, check-out, diagnosis and getting drugs. The reported will be issued within an hour, thus a rapid immune detection service was established in out-patients department. Methods: 1. ACS-180 automatic chemiluminescence machine is used based on the principle of chemiluminescence immune methods. 2. The reagents are provided by Ciba-Comig Company of USA, composed of anti acridinium ester antibody of liquid phase and particulate antigen of solid phase wrapped in magnetic powder. 3. Calibration and quality control: high and low concentration are set for each calibration fluid with attached standard curve. Product for quality controlling includes three concentration of low, moderate and high. Results: 1. rapid machine detection for sample: serum is replaced with plasma coagulated by heparin, and comparison among series of methods using serum or plasma suggest no significant difference exists. 2. The problem about fasting detection: chemiluminescence machine measure optical density directly, with the results hardly being influenced by turbidity. But attention should be paid to the treatment of lipid turbid samples. 3. Other innovations: (1) direct placement of sample tube on machine: a cushion is placed on sample plate to transfer sample to machine directly after centrifugation, saving time and reducing the accident in sample transference. (2) for HCG quantification in blood and urine, 'gold criteria' is used firstly in screening to determine approximately the dilution range, with an advantage of saving time and reagent as well as accuracy. (3) we design a

  8. Conglutinin exhibits a complement-dependent enhancement of the respiratory burst of phagocytes stimulated by E. coli

    DEFF Research Database (Denmark)

    Friis, P; Svehag, S E; Andersen, Ove

    1991-01-01

    . Conglutinin enhances, in a dose-dependent manner, the respiratory burst of spleen cells stimulated with serum-opsonized Escherichia coli. The enhancement was only demonstrable in the presence of a functional complement system. The conglutinin-mediated enhancement of the respiratory burst was inhibited......Conglutinin is a mammalian C-type lectin which shows anti-bacterial activity when tested in vivo and in vitro. This study concerns the effect of conglutinin on the respiratory burst of murine spleen cells, using a chemiluminescence assay for measurement of generated reactive oxygen metabolites...

  9. Enhanced visible-light-induced photocatalytic activity of α-Fe2O3 adsorbing redox enzymes

    Directory of Open Access Journals (Sweden)

    Kai Kamada

    2015-03-01

    Full Text Available We report fabrication of hybrid photocatalyst composed of an n-type semiconductor (α-Fe2O3 and a redox enzyme (horseradish peroxidase; HRP, and its performance for oxidation of luminol in an aqueous solution. The hybrid photocatalyst is simply formed via physical adsorption of HRP to an α-Fe2O3 sintered body. Under visible light irradiation, the bare α-Fe2O3 with a narrow bandgap photocatalytically oxidizes luminol along with blue emission that can be used as an indicator of the photocatalytic performance. The blue emission is largely strengthened after the adsorption of HRP, demonstrating that the presence of enzyme improves apparent photocatalytic activity of α-Fe2O3. The favorable effect is derived from synergistic oxidation of luminol by the biocatalysts (HRP as well as by the photocatalyst (α-Fe2O3. In this paper, influence of excitation wavelength, adsorption amount of HRP, and reaction temperature on the overall photocatalytic activity are elucidated, and then a reaction mechanism of the proposed novel hybrid photocatalyst is discussed in detail.

  10. Simultaneous determination of chromium(III) and chromium(VI) in aqueous solutions by ion chromatography and chemiluminescence detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jøns, O; Nielsen, B

    1992-01-01

    A method for the simultaneous determination of chromium(iii) and chromium(vi) in a flow system based on chemiluminescence was developed. A Dionex cation-exchange guard column was used to separate chromium(iii) from chromium(vi), and chromium(vi) was reduced by potassium sulfite, whereupon both...

  11. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer

    Directory of Open Access Journals (Sweden)

    Xiaoling Fu

    2018-03-01

    Full Text Available The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA was presented for the clinical determination and analysis of human epididymis protein 4 (HE4 in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0–1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA, with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum. Keywords: Chemiluminescence immunoassay, Magnetic particles, Human epididymis protein 4

  12. Luminescent chemical waves in the Cu(II)-catalyzed oscillatory oxidation of SCN- ions with hydrogen peroxide.

    Science.gov (United States)

    Pekala, Katarzyna; Jurczakowski, Rafał; Lewera, Adam; Orlik, Marek

    2007-05-10

    The oscillatory oxidation of thiocyanate ions with hydrogen peroxide, catalyzed by Cu2+ ions in alkaline media, was so far observed as occurring simultaneously in the entire space of the batch or flow reactor. We performed this reaction for the first time in the thin-layer reactor and observed the spatiotemporal course of the above process, in the presence of luminol as the chemiluminescent indicator. A series of luminescent patterns periodically starting from the random reaction center and spreading throughout the entire solution layer was reported. For a batch-stirred system, the bursts of luminescence were found to correlate with the steep decreases of the oscillating Pt electrode potential. These novel results open possibilities for further experimental and theoretical investigations of those spatiotemporal patterns, including studies of the mechanism of this chemically complex process.

  13. Sensitive and selective determination of fluvoxamine maleate using a sensitive chemiluminescence system based on the alkaline permanganate-Rhodamine B-gold nanoparticles reaction.

    Science.gov (United States)

    Hassanzadeh, Javad; Amjadi, Mohammad

    2015-06-01

    A high-yield chemiluminescence (CL) system based on the alkaline permanganate-Rhodamine B reaction was developed for the sensitive determination of fluvoxamine maleate (Flu). Rhodamine B is oxidized by alkaline KMnO4 and a weak CL emission is produced. It was demonstrated that gold nanoparticles greatly enhance this CL emission due to their interaction with Rhodamine B molecules. It is also observed that sodium dodecyl sulfate, an anionic surfactant, can strongly increase this enhancement. In addition, it was demonstrated that a notable decrease in the CL intensity is observed in the presence of Flu. This may be related to Flu oxidation with KMnO4 . There is a linear relationship between the decrease in CL intensity and the Flu concentration over a range of 2-300 µg/L. A new simple, rapid and sensitive CL method was developed for the determination of Flu with a detection limit (3s) of 1.35 µg/L. The proposed method was used for the determination of Flu in pharmaceutical and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Effect of desensitizing agents on dentin permeability.

    Science.gov (United States)

    Ishihata, Hiroshi; Kanehira, Masafumi; Nagai, Tomoko; Finger, Werner J; Shimauchi, Hidetoshi; Komatsu, Masashi

    2009-06-01

    To investigate the in vitro efficacy of two dentin desensitizing products at reducing liquid permeability through human dentin discs. The tested hypothesis was that the products, in spite of different chemical mechanisms were not different at reducing or eliminating flow through dentin discs. Dentin slices (1 mm thick) were prepared from 16 extracted human third molars and their permeability was indirectly recorded in a split chamber model, using a chemiluminescence technique, after EDTA treatment (control), after soaking with albumin, and after desensitizer application. Two products were studied: MS Coat, a self-curing resin-containing oxalate product, and Gluma Desensitizer, a glutaraldehyde/HEMA-based agent without initiator. The dentin slices were mounted between an upper chamber, filled with an aqueous solution of 1% potassium ferricyanide and 0.3% hydrogen peroxide, and a lower chamber filled with 1% sodium hydroxide solution and 0.02% luminol. The upper solution was pressurized, and upon contact with the luminol solution a photochemical signal was generated and recorded as a measure of permeability throughout two consecutive pressurizing cycles at 2.5 and 13 kPa (26 and 133 cm H2O), respectively. The permeability of the control and albumin-soaked samples was similarly high. After application of the desensitizing agents, dentin permeability was reduced to virtually zero at both pressure levels (P < 0.001).

  15. Fructose and tagatose protect against oxidative cell injury by iron chelation.

    Science.gov (United States)

    Valeri, F; Boess, F; Wolf, A; Göldlin, C; Boelsterli, U A

    1997-01-01

    To further investigate the mechanism by which fructose affords protection against oxidative cell injury, cultured rat hepatocytes were exposed to cocaine (300 microM) or nitrofurantoin (400 microM). Both drugs elicited massively increased lactate dehydrogenase release. The addition of the ketohexoses D-fructose (metabolized via glycolysis) or D-tagatose (poor glycolytic substrate) significantly attenuated cocaine- and nitrofurantoin-induced cell injury, although both fructose and tagatose caused a rapid depletion of ATP and compromised the cellular energy charge. Furthermore, fructose, tagatose, and sorbose all inhibited in a concentration-dependent manner (0-16 mM) luminolenhanced chemiluminescence (CL) in cell homogenates, indicating that these compounds inhibit the iron-dependent reactive oxygen species (ROS)-mediated peroxidation of luminol. Indeed, both Fe2+ and Fe3+ further increased cocaine-stimulated CL, which was markedly quenched following addition of the ketohexoses. The iron-independent formation of superoxide anion radicals (acetylated cytochrome c reduction) induced by the prooxidant drugs remained unaffected by fructose or tagatose. The iron-chelator deferoxamine similarly protected against prooxidant-induced cell injury. In contrast, the nonchelating aldohexoses D-glucose and D-galactose did not inhibit luminol CL nor did they protect against oxidative cell injury. These data indicate that ketohexoses can effectively protect against prooxidant-induced cell injury, independent of their glycolytic metabolism, by suppressing the iron-catalyzed formation of ROS.

  16. Egg-Citing! Isolation of Protoporphyrin IX from Brown Eggshells and Its Detection by Optical Spectroscopy and Chemiluminescence

    Science.gov (United States)

    Dean, Michelle L.; Miller, Tyson A.; Bruckner, Christian

    2011-01-01

    A simple and cost-effective laboratory experiment is described that extracts protoporphyrin IX from brown eggshells. The porphyrin is characterized by UV-vis and fluorescence spectroscopy. A chemiluminescence reaction (peroxyoxalate ester fragmentation) is performed that emits light in the UV region. When the porphyrin extract is added as a fluor…

  17. A multipumping flow system for in vitro screening of peroxynitrite scavengers.

    Science.gov (United States)

    Ribeiro, Marta F T; Dias, Ana C B; Santos, João L M; Fernandes, Eduarda; Lima, José L F C; Zagatto, Elias A G

    2007-09-01

    Peroxynitrite anion is a reactive nitrogen species formed in vivo by the rapid, controlled diffusion reaction between nitric oxide and superoxide radicals. By reacting with several biological molecules, peroxynitrite may cause important cellular and tissue deleterious effects, which have been associated with many diseases. In this work, an automated flow-based procedure for the in vitro generation of peroxynitrite and subsequent screening of the scavenging activity of selected compounds is developed. This procedure involves a multipumping flow system (MPFS) and exploits the ability of compounds such as lipoic acid, dihydrolipoic acid, cysteine, reduced glutathione, oxidized glutathione, sulindac, and sulindac sulfone to inhibit the chemiluminescent reaction of luminol with peroxynitrite under physiological simulated conditions. Peroxynitrite was generated in the MPFS by the online reaction of acidified hydrogen peroxide with nitrite, followed by a subsequent stabilization by merging with a sodium hydroxide solution to rapidly quench the developing reaction. The pulsed flow and the timed synchronized insertion of sample and reagent solutions provided by the MPFS ensure the establishment of the reaction zone only inside the flow cell, thus allowing maximum chemiluminescence emission detection. The results obtained for the assayed compounds show that, with the exception of oxidized glutathione, all are highly potent scavengers of peroxynitrite at the studied concentrations.

  18. The research and preparation of a novel nano biodegradable polymer external reinforcement

    International Nuclear Information System (INIS)

    Zhang Xiangman; Chen Bin; Fu Weiguo; Fang Zhengdong; Liu Zhenjie; Lu Weifeng; Shi Zhengyu; Chen Lili; Chen Tao

    2011-01-01

    The use of current drug-loaded vascular scaffolds is limited in sustained drug release and stability studies in clinical and preclinical trials. We found that poly(L-glutamic acid)-b-poly(propylene oxide)-b-poly(L-glutamic acid) (PLGA-b-PPO-b-PLGA) triblock copolymers can deliver multiple poorly water-soluble drugs (e.g., Paclitaxel) at clinically relevant doses. In this study, we synthesized a new drug-loaded vascular external graft with electrospun nanofibrous scaffolds [poly(L-lactide-co-ε-caprolactone) (PLCL):fibrinogen; 2:1 (w/w)] and drug-loaded PLGA-b-PPO-b-PLGA micelles. Cell proliferation and viability assay results showed that beagle smooth muscle cells grew well on the surface of vascular graft-coated micelles at a percentages of 10% (w/w) GPG:PLCL-fibrinogen. This study demonstrates that micelle-coated electrospun PLCL-fibrinogen vascular scaffolds have potential applications in vascular tissue engineering.

  19. Application of Box–Behnken design in the optimization of new peroxyoxalate–H{sub 2}O{sub 2} chemiluminescence system using furan derivatives as blue activators

    Energy Technology Data Exchange (ETDEWEB)

    Chaichi, M.J., E-mail: jchaichi@yahoo.com [Faculty of Chemistry, Mazandaran University, Babolsar (Iran, Islamic Republic of); Azizi, S.N.; Alijanpour, O.; Heidarpour, M. [Faculty of Chemistry, Mazandaran University, Babolsar (Iran, Islamic Republic of); Qandalee, M. [Department of Biology, Garmsar Branch, Islamic Azad University, Garmsar (Iran, Islamic Republic of)

    2013-06-15

    The non-commercially synthesized and purified furan derivatives are of great interest as fluorescent emitters for peroxyoxalate chemiluminescence (PO-CL). The reaction of oxalic ester such as bis-(2,4,6-trichloro-phenyl) oxalate (TCPO) with H{sub 2}O{sub 2} can lead to the excitation of an appropriate activator via the formation of a 1,2-dioxetanedione intermediate. In this study, two furan derivatives were used as activators which produce a blue light in the chemiluminescence systems. In the following, the Box–Behnken design matrix and response surface methodology (RSM) have been applied to design the experiments to study the relationship between the chemiluminescence intensities and the three most important operating variables such as sodium salicylate (5×10{sup −4}–5×10{sup −3} M), furan (10{sup −5}–10{sup −3} M) and hydrogen peroxide (10{sup −3}–10{sup −1} M) concentrations, and also to evaluate the interactive effects of these variables on the CL emission of TCPO system. Totally 15 experiments were conducted in the present study towards the construction of a quadratic model. Independent variables of sodium salicylate, hydrogen peroxide and furan concentration have the significance value of p=0.05, in both the systems, which explicitly shows the importance of these variables in the CL emission of TCPO. Values of Prob>F less than 0.0001 indicated that the model terms are significant for the CL emission of TCPO. Moreover, the regression equation coefficients were calculated and the data fitted to a second-order polynomial equation for CL emission of TCPO. -- Highlights: ► Furan derivatives are used as activators for peroxyoxalate chemiluminescence. ► The activators produce a blue light in the chemiluminescence system. ► The Box–Behnken design matrix and response surface methodology (RSM) is used. ► The most important variables are sodium salicylate, furan and hydrogen peroxide. ► The data are fitted to a second-order polynomial

  20. Chemiluminescent determination of vanadium(IV) using a cinchomeronic hydrazide-H2O2 system and flow injection analysis

    International Nuclear Information System (INIS)

    Pradana Perez, J.A.; Alegria, J.S. Durand; Hernando, P. Fernandez; Sierra, A. Narros

    2005-01-01

    This paper proposes a new chemiluminescent flow injection analysis (FIA) method for the determination of vanadium(IV) ions in aqueous media. The method is based on the chemiluminescent reaction that occurs between cinchomeronic hydrazide (CH) and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. The chemical and physical variables involved in the flow injection system are optimised using a modified simplex method. Vanadium ions can be detected in the 0.08 and 1.00 μg mL -1 range; the detection limit for a signal-to-noise ratio of 3 is 0.08 μg mL -1 . Great variations in the quantum yield were observed when cobalt(II), chromium(III), copper(II) and/or nickel(II) were present in the reaction medium. The proposed method is selective and simple, and can be successfully used to analyse water samples without the need for separation or preconcentration processes

  1. Radiation-induced apoptosis of neural precursors cell cultures: early modulation of the response mediated by reactive oxygen and nitrogen species (ROS/RNS)

    Energy Technology Data Exchange (ETDEWEB)

    Gisone, P.; Dubner, D.; Robello, E.; Michelin, S.; Perez, M. R.

    2004-07-01

    Apoptosis, the typical mode of radiation-induced cell death in developing Central Nervous System (CNS), is closely related with the oxidative status. Enhanced radiation-induced generation of ROS/RNS has been observed after exposures to low radiation doses leading to cellular amplification of signal transduction and further molecular and cellular radiation-responses. Moreover Nitric oxide (NO) and hydroxyl radical are implicated in dopaminergic neurotoxicity in different parading. This study is an attempt to address the participation of radiation-induced free radicals production, the contribution of endogenous NO generation, and the excitonic pathway, in the radiation-induced apoptosis of neural cortical precursors. Cortical cells obtained from at 17 gestational day (gd) were irradiated with doses from 0,2 Gy to 2 Gy at a dose-rate of 0.3 Gy/m. A significant decrease of Luminol-dependent Chemiluminescence was evident 30 m after irradiation reaching basal levels at 120 m follow for a tendency to increasing values Incubations with Superoxide Dismatuse (SOD) decreased significantly the chemiluminescence in irradiated samples NO content estimated by measuring the stable products NO{sub 2} and NO{sub 3} released to the culture medium in the same period, has shown a time-dependent accumulation from 1 h post-irradiation. the apoptosis, determined 24 h post-irradiation by flow cytometry, morphology and DNA fragmentation revealed a dose-effect relationship with significant differences from 0.4 Gy. The samples pre-treated with 10 mM of N-acetyl cysteine (NAC) a precursor of intracellular GSH synthesis, shown a significant decrease of the apoptosis. Apoptosis was significantly increased in irradiated cells after inhibition of nitric oxide synthase (NOS) byL-NAME. We conclude that ROS/RNS play a pivotal role in the early signaling pathways leading to a radiation-induced cell death. (Author) 40 refs.

  2. Radiation-induced apoptosis of neural precursors cell cultures: early modulation of the response mediated by reactive oxygen and nitrogen species (ROS/RNS)

    International Nuclear Information System (INIS)

    Gisone, P.; Dubner, D.; Robello, E.; Michelin, S.; Perez, M. R.

    2004-01-01

    Apoptosis, the typical mode of radiation-induced cell death in developing Central Nervous System (CNS), is closely related with the oxidative status. Enhanced radiation-induced generation of ROS/RNS has been observed after exposures to low radiation doses leading to cellular amplification of signal transduction and further molecular and cellular radiation-responses. Moreover Nitric oxide (NO) and hydroxyl radical are implicated in dopaminergic neurotoxicity in different parading. This study is an attempt to address the participation of radiation-induced free radicals production, the contribution of endogenous NO generation, and the excitonic pathway, in the radiation-induced apoptosis of neural cortical precursors. Cortical cells obtained from at 17 gestational day (gd) were irradiated with doses from 0,2 Gy to 2 Gy at a dose-rate of 0.3 Gy/m. A significant decrease of Luminol-dependent Chemiluminescence was evident 30 m after irradiation reaching basal levels at 120 m follow for a tendency to increasing values Incubations with Superoxide Dismatuse (SOD) decreased significantly the chemiluminescence in irradiated samples NO content estimated by measuring the stable products NO 2 and NO 3 released to the culture medium in the same period, has shown a time-dependent accumulation from 1 h post-irradiation. the apoptosis, determined 24 h post-irradiation by flow cytometry, morphology and DNA fragmentation revealed a dose-effect relationship with significant differences from 0.4 Gy. The samples pre-treated with 10 mM of N-acetyl cysteine (NAC) a precursor of intracellular GSH synthesis, shown a significant decrease of the apoptosis. Apoptosis was significantly increased in irradiated cells after inhibition of nitric oxide synthase (NOS) byL-NAME. We conclude that ROS/RNS play a pivotal role in the early signaling pathways leading to a radiation-induced cell death. (Author) 40 refs

  3. Glucose impairs aspirin inhibition in platelets through a NAD(P)H oxidase signaling pathway.

    Science.gov (United States)

    Kobzar, Gennadi; Mardla, Vilja; Samel, Nigulas

    2017-07-01

    Hyperglycemia has been suggested to play a role in the increased platelet resistance to antiplatelet therapy in patients with diabetes mellitus. Exposure to high glucose impairs platelet inhibition by aspirin. It has been found that antioxidant agents reduce the effect of glucose, confirming the involvement of reactive oxygen species (ROS) in the effect of glucose. The aim of the study was to examine the mechanism of ROS increase by high glucose in aspirin-treated platelets. Platelet aggregation was measured by the optical method, and the production of ROS was detected using luminol-dependent horseradish peroxidase-enhanced chemiluminescence. We found that glucose did not affect ADP-induced platelet aggregation. However, it reduced the effect of aspirin on platelet aggregation, which was accompanied by an increase in ROS generation. The inhibition of NAD(P)H oxidase (NOX) prevented the glucose effect and ROS generation. The same result was recorded after the inhibition of p38 mitogen-activated protein kinases (p38 MAPK), phospholipase A 2 (PLA 2 ) or 12-lipoxygenase (12-LOX). The inhibition of TxA 2 receptor did not decrease the effect of glucose indicating that the effect was not caused by activation of TxA 2 receptors. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF

    Science.gov (United States)

    Wu, Yi; Modica, Vincent; Yu, Xilong; Li, Fei; Grisch, Frédéric

    2018-01-01

    The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.

  5. Effects of Non-Equilibrium Plasmas on Low-Pressure, Premixed Flames. Part 1: CH* Chemiluminescence, Temperature, and OH

    Science.gov (United States)

    2018-01-16

    Adamovich, Jeffrey A. Sutton1 Department of Mechanical and Aerospace Engineering , Ohio State University Abstract In this paper, we... chemistry . Qualitative imaging of CH* chemiluminescence indicates that during plasma discharge, the luminous flame zone is shifted upstream towards...Sutton Department of Mechanical and Aerospace Engineering , Ohio State University 1. Introduction In recent years, considerable interest has

  6. Effects of poly(L-lactide-ε-caprolactone) and magnesium hydroxide additives on physico-mechanical properties and degradation of poly(L-lactic acid).

    Science.gov (United States)

    Kang, Eun Young; Lih, Eugene; Kim, Ik Hwan; Joung, Yoon Ki; Han, Dong Keun

    2016-01-01

    Biodegradable poly(L-lactic acid) (PLLA) is one of the most widely used polymer in biomedical devices, but it still has limitations such as inherent brittleness and acidic degradation products. In this work, PLLA blends with poly(L-lactide-ε-caprolactone) (PLCL) and Mg(OH)2 were prepared by the thermal processing to improve their physico-mechanical and thermal properties. In addition, the neutralizing effect of Mg(OH)2 was evaluated by degradation study. The elongation of PLLA remarkably increased from 3 to 164.4 % and the glass transition temperature (Tg) of PLLA was slightly reduced from 61 to 52 °C by adding PLCL additive. Mg(OH)2 in polymeric matrix not only improved the molecular weight reduction and mechanical strength of PLLA, but also neutralized the acidic byproducts generated during polyester degradation. Therefore, the results demonstrated that the presence of PLCL and Mg(OH)2 additives in PLLA matrix could prevent the thermal decomposition and control degradation behavior of polyester.

  7. Chemiluminescence of graphene quantum dots and its application to the determination of uric acid

    International Nuclear Information System (INIS)

    Amjadi, Mohammad; Manzoori, Jamshid L.; Hallaj, Tooba

    2014-01-01

    We report on the chemiluminescence (CL) of graphene quantum dots (GQDs) induced by direct chemical oxidation. GQDs were prepared by a simple carbonization method and characterized by X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy and Raman spectroscopy. It was found that Ce(IV) could oxidize GQDs to produce a relatively intense CL emission. The mechanism of CL generation was investigated based on the fluorescence and CL emission spectra. It was attributed to the radiative recombination of oxidant-injected holes and thermally excited electrons in the GQDs. In order to show the analytical application potential of GQDs-Ce(IV) CL system, it was applied to the determination of uric acid. Under the optimized conditions, the proposed CL system exhibited excellent analytical performance for determination of uric acid in the range of 1.0×10 −6 M–5.0×10 −4 M with a limit of detection of 5.0×10 −7 M. The method was applied to the determination of uric acid in human plasma and urine samples, with satisfactory results. - Highlights: • Chemiluminescence of graphene quantum dots by direct oxidation was studied. • Intense CL is produced by reaction of graphene quantum dots with Ce(IV). • The new CL system was applied to determination of uric acid in plasma and urine

  8. Chemiluminescence of graphene quantum dots and its application to the determination of uric acid

    Energy Technology Data Exchange (ETDEWEB)

    Amjadi, Mohammad, E-mail: amjadi@tabrizu.ac.ir; Manzoori, Jamshid L.; Hallaj, Tooba

    2014-09-15

    We report on the chemiluminescence (CL) of graphene quantum dots (GQDs) induced by direct chemical oxidation. GQDs were prepared by a simple carbonization method and characterized by X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy and Raman spectroscopy. It was found that Ce(IV) could oxidize GQDs to produce a relatively intense CL emission. The mechanism of CL generation was investigated based on the fluorescence and CL emission spectra. It was attributed to the radiative recombination of oxidant-injected holes and thermally excited electrons in the GQDs. In order to show the analytical application potential of GQDs-Ce(IV) CL system, it was applied to the determination of uric acid. Under the optimized conditions, the proposed CL system exhibited excellent analytical performance for determination of uric acid in the range of 1.0×10{sup −6} M–5.0×10{sup −4} M with a limit of detection of 5.0×10{sup −7} M. The method was applied to the determination of uric acid in human plasma and urine samples, with satisfactory results. - Highlights: • Chemiluminescence of graphene quantum dots by direct oxidation was studied. • Intense CL is produced by reaction of graphene quantum dots with Ce(IV). • The new CL system was applied to determination of uric acid in plasma and urine.

  9. Microplate-reader method for the rapid analysis of copper in natural waters with chemiluminescence detection

    Directory of Open Access Journals (Sweden)

    Axel eDurand

    2013-01-01

    Full Text Available We have developed a method for the determination of copper in natural waters at nanomolar levels. The use of a microplate-reader minimises sample processing time (~ 25 sec per sample, reagent consumption (~ 120 μL per sample and sample volume (~ 700 μL. Copper is detected by chemiluminescence. This technique is based on the formation of a complex between copper and 1,10-phenanthroline and the subsequent emission of light during the oxidation of the complex by hydrogen peroxide. Samples are acidified to pH 1.7 and then introduced directly into a 24-well plate. Reagents are added during data acquisition via two reagent injectors. When trace metal clean protocols are employed, the reproducibility is generally less then 7% on blanks and the detection limit is 0.7 nM for seawater and 0.4 nM for freshwater. More than 100 samples per hour can be analyzed with this technique, which is simple, robust, and amenable to at-sea analysis. Seawater samples from Storm Bay in Tasmania illustrate the utility of the method for environmental science. Indeed other trace metals for which optical detection methods exist (e.g. chemiluminescence, fluorescence and absorbance could be adapted to the microplate-reader.

  10. Sonochemical fabrication of 8-hydroxyquinoline aluminum (Alq3) nanoflowers with high electrogenerated chemiluminescence.

    Science.gov (United States)

    Mao, Chang-Jie; Wang, Dan-Chen; Pan, Hong-Cheng; Zhu, Jun-Jie

    2011-03-01

    Well-defined Alq(3) nanoflowers were fabricated via a facile and fast sonochemical route. X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), field-emission scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and shape of the as-prepared product. The results showed that the resulting Alq(3) was composed of nanobelts with thickness about 50 nm, average widths of 200 nm, and length up to 10 μm. The Alq(3) nanoflowers exhibited good electrogenerated chemiluminescence behavior. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Flow-injection system for automated dissolution testing of isoniazid tablets with chemiluminescence detection.

    Science.gov (United States)

    Li, B; Zhang, Z; Liu, W

    2001-05-30

    A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.

  12. The antioxidants curcumin and quercetin inhibit inflammatory processes associated with arthritis.

    Science.gov (United States)

    Jackson, J K; Higo, T; Hunter, W L; Burt, H M

    2006-04-01

    Curcumin and quercetin are antioxidant molecules with anti-proliferative, anti-inflammatory and immunosuppressive activities. The objective of this study was to investigate the inhibitory activity of these agents using four assays of inflammatory aspects of arthritis. Crystal-induced neutrophil activation was measured by luminol-dependent chemiluminescence. Synoviocyte proliferation was measured by an MTS assay using HIG-82 rabbit synoviocytes in cell culture. Chondrocyte (cultured primary cells) expression of the matrix metalloproteinases collagenase and stromelysin was measured by Northern Blot analysis. Angiogenesis was measured using the chorioallantoic membrane of the chick embryo. Both agents inhibited neutrophil activation, synoviocyte proliferation and angiogenesis. Curcumin strongly inhibited collagenase and stromelysin expression at micromolar concentrations whereas quercetin had no effect in this assay. These studies suggest that curcumin and to a lesser extent quercetin may offer therapeutic potential for the treatment of crystal-induced arthritis or rheumatoid arthritis.

  13. Determination of neurotransmitters and their metabolites using one- and two-dimensional liquid chromatography with acidic potassium permanganate chemiluminescence detection.

    Science.gov (United States)

    Holland, Brendan J; Conlan, Xavier A; Stevenson, Paul G; Tye, Susannah; Reker, Ashlie; Barnett, Neil W; Adcock, Jacqui L; Francis, Paul S

    2014-09-01

    High-performance liquid chromatography with chemiluminescence detection based on the reaction with acidic potassium permanganate and formaldehyde was explored for the determination of neurotransmitters and their metabolites. The neurotransmitters norepinephrine and dopamine were quantified in the left and right hemispheres of rat hippocampus, nucleus accumbens and prefrontal cortex, and the metabolites vanillylmandelic acid, 3,4-dihydrophenylacetic acid, 5-hydroxyindole-3-acetic acid and homovanillic acid were identified in human urine. Under optimised chemiluminescence reagent conditions, the limits of detection for these analytes ranged from 2.5 × 10(-8) to 2.5 × 10(-7) M. For the determination of neurotransmitter metabolites in urine, a two-dimensional high-performance liquid chromatography (2D-HPLC) separation operated in heart-cutting mode was developed to overcome the peak capacity limitations of the one-dimensional separation. This approach provided the greater separation power of 2D-HPLC with analysis times comparable to conventional one-dimensional separations.

  14. In Vivo Host Response and Degradation of Copolymer Scaffolds Functionalized with Nanodiamonds and Bone Morphogenetic Protein 2.

    Science.gov (United States)

    Suliman, Salwa; Sun, Yang; Pedersen, Torbjorn O; Xue, Ying; Nickel, Joachim; Waag, Thilo; Finne-Wistrand, Anna; Steinmüller-Nethl, Doris; Krueger, Anke; Costea, Daniela E; Mustafa, Kamal

    2016-03-01

    The aim is to evaluate the effect of modifying poly[(l-lactide)-co-(ε-caprolactone)] scaffolds (PLCL) with nanodiamonds (nDP) or with nDP+physisorbed BMP-2 (nDP+BMP-2) on in vivo host tissue response and degradation. The scaffolds are implanted subcutaneously in Balb/c mice and retrieved after 1, 8, and 27 weeks. Molecular weight analysis shows that modified scaffolds degrade faster than the unmodified. Gene analysis at week 1 shows highest expression of proinflammatory markers around nDP scaffolds; although the presence of inflammatory cells and foreign body giant cells is more prominent around the PLCL. Tissue regeneration markers are highly expressed in the nDP+BMP-2 scaffolds at week 8. A fibrous capsule is detectable by week 8, thinnest around nDP scaffolds and at week 27 thickest around PLCL scaffolds. mRNA levels of ALP, COL1α2, and ANGPT1 are significantly upregulating in the nDP+BMP-2 scaffolds at week 1 with ectopic bone seen at week 8. Even when almost 90% of the scaffold is degraded at week 27, nDP are observable at implantation areas without adverse effects. In conclusion, modifying PLCL scaffolds with nDP does not aggravate the host response and physisorbed BMP-2 delivery attenuates inflammation while lowering the dose of BMP-2 to a relatively safe and economical level. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A High Sensitivity Micro Format Chemiluminescence Enzyme Inhibition Assay for Determination of Hg(II

    Directory of Open Access Journals (Sweden)

    Kanchanmala Deshpande

    2010-06-01

    Full Text Available A highly sensitive and specific enzyme inhibition assay based on alcohol oxidase (AlOx and horseradish peroxidase (HRP for determination of mercury Hg(II in water samples has been presented. This article describes the optimization and miniaturization of an enzymatic assay using a chemiluminescence reaction. The analytical performance and detection limit for determination of Hg(II was optimized in 96 well plates and further extended to 384 well plates with a 10-fold reduction in assay volume. Inhibition of the enzyme activity by dissolved Hg(II was found to be linear in the range 5–500 pg.mL−1 with 3% CVin inter-batch assay. Due to miniaturization of assay in 384 well plates, Hg(II was measurable as low as 1 pg.mL−1 within15 min. About 10-fold more specificity of the developed assay for Hg(II analysis was confirmed by challenging with interfering divalent metal ions such as cadmium Cd(II and lead Pb(II. Using the proposed assay we could successfully demonstrate that in a composite mixture of Hg(II, Cd(II and Pb(II, inhibition by each metal ion is significantly enhanced in the presence of the others. Applicability of the proposed assay for the determination of the Hg(II in spiked drinking and sea water resulted in recoveries ranging from 100–110.52%.

  16. On methods for the detection of reactive oxygen species generation by human spermatozoa: analysis of the cellular responses to catechol oestrogen, lipid aldehyde, menadione and arachidonic acid.

    Science.gov (United States)

    Aitken, R J; Smith, T B; Lord, T; Kuczera, L; Koppers, A J; Naumovski, N; Connaughton, H; Baker, M A; De Iuliis, G N

    2013-03-01

    Oxidative stress is known to have a major impact on human sperm function and, as a result, there is a need to develop sensitive methods for measuring reactive oxygen species (ROS) generation by these cells. A variety of techniques have been developed for this purpose including chemiluminescence (luminol and lucigenin), flow cytometry (MitoSOX Red, dihydroethidium, 4,5-diaminofluorescein diacetate and 2',7'-dichlorodihydrofluorescein diacetate) and spectrophotometry (nitroblue tetrazolium). The relative sensitivity of these assays and their comparative ability to detect ROS generated in different subcellular compartments of human spermatozoa, have not previously been investigated. To address this issue, we have compared the performance of these assays when ROS generation was triggered with a variety of reagents including 2-hydroxyestradiol, menadione, 4-hydroxynonenal and arachidonic acid. The results revealed that menadione predominantly induced release of ROS into the extracellular space where these metabolites could be readily detected by luminol-peroxidase and, to a lesser extent, 2',7'-dichlorodihydrofluorescein. However, such sensitivity to extracellular ROS meant that these assays were particularly vulnerable to interference by leucocytes. The remaining reagents predominantly elicited ROS generation by the sperm mitochondria and could be optimally detected by MitoSOX Red and DHE. Examination of spontaneous ROS generation by defective human spermatozoa revealed that MitoSOX Red was the most effective indicator of oxidative stress, thereby emphasizing the general importance of mitochondrial dysregulation in the aetiology of defective sperm function. © 2013 American Society of Andrology and European Academy of Andrology.

  17. Detection of pyrrolizidine alkaloids using flow analysis with both acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence

    International Nuclear Information System (INIS)

    Gorman, Bree A.; Barnett, Neil W.; Bos, Richard

    2005-01-01

    For the first time, analytically useful chemiluminescence was elicited from the reactions of the pyrrolizidine alkaloids. Heliotrine, retronecine, supinine, monocrotaline and echinatine N-oxide yielded chemiluminescence upon reaction with tris(2,2'-bipyridyl)ruthenium(II) whilst lasiocarpine, its N-oxide and supinine elicited light upon reaction with acidic potassium permanganate. Detection limits for heliotrine were 1.25 x 10 -7 M and 9 x 10 -9 M for tris(2,2'-bipyridyl)ruthenium(III) perchlorate with flow injection analysis (FIA) and the silica-immobilised reagent (4-[4-(dichloromethylsilanyl)-butyl]-4'-methyl-2,2'-bipyridine)bis (2,2'-bipyridyl)ruthenium(II) with sequential injection analysis (SIA), respectively. Lasiocarpine was detectable at 1.4 x 10 -7 M using acidic potassium permanganate with FIA. Additionally, the silica-immobilised reagent was optimised with respect to the oxidant (ammonium ceric nitrate) concentration and the aspiration times which afforded a detection limit for codeine of 5 x 10 -10 M using SIA

  18. Integrated luminometer for the determination of trace metals in seawater using fluorescence, phosphorescence and chemiluminescence detection

    OpenAIRE

    Worsfold, P. J.; Achterberg, E. P.; Bowie, A. R.; Cannizzaro, V.; Charles, S.; Costa, J. M.; Dubois, F.; Pereiro, R.; San Vicente, B.; Sanz-Medel, A.; Vandeloise, R.; Donckt, E. Vander; Wollast, P.; Yunus, S.

    2002-01-01

    The paper describes an integrated luminometer able to perform fluorescence (FL), room temperature phosphorescence (RTP) and chemiluminescence (CL) measurements on seawater samples. The technical details of the instrumentation are presented together with flow injection (FI) manifolds for the determination of cadmium and zinc (by FL), lead (RTP) and cobalt (CL). The analytical figures of merit are given for each mainfold and results are presented for the determination of the four trace metals i...

  19. Radiation-Induced Graft Polymerization of Vinyl Monomers with Anion Groups onto MWNT Supports and Their Application as Electrogenerated Chemiluminescence (ECL Biosensors

    Directory of Open Access Journals (Sweden)

    Ji-Hye Park

    2014-01-01

    Full Text Available Vinyl polymer-grafted multiwalled carbon nanotube (MWNT supports with anion groups were prepared for use as biosensor supports by radiation-induced graft polymerization (RIGP of the vinyl monomers acryloyl diphosphoric acid (ADPA, acrylic acid (AA, sodium styrenesulfonate (NaSS, and methacrylic acid (MA onto the surface of MWNTs. The electrogenerated chemiluminescence sensors based on a glass carbon electrode (ECL-GCE and a screen printed electrode (ECL-SPE were fabricated by immobilization of Ru(bpy3 2+ complex after coating of vinyl polymer-grafted MWNT inks on the surface of the GCE and SPE without any polymer binders in order to obtain high electrogenerated chemiluminescence intensity. For detection of alcohol concentration, alcohol dehydrogenase (ADH was immobilized onto an ECL-GCE sensor prepared by poly(NaSS-g-MWNT supports. The prepared biosensor based on ADH is suitable for the detection of ethanol concentration in commercial drinks.

  20. Development and validation of a direct sandwich chemiluminescence immunoassay for measuring DNA adducts of benzo[a]pyrene and other polycyclic aromatic hydrocarbons

    DEFF Research Database (Denmark)

    Georgiadis, Panagiotis; Kovács, Katalin; Kaila, Stella

    2012-01-01

    We have developed and validated a sandwich chemiluminescence immunoassay (SCIA) which measures polycyclic aromatic hydrocarbon (PAH)-DNA adducts combining high throughput and adequate sensitivity, appropriate for evaluation of adduct levels in human population studies. Fragmented DNA is incubated...

  1. The determination of psilocin and psilocybin in hallucinogenic mushrooms by HPLC utilizing a dual reagent acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection system.

    Science.gov (United States)

    Anastos, Nicole; Lewis, Simon W; Barnett, Neil W; Sims, D Noel

    2006-01-01

    This paper describes a procedure for the determination of psilocin and psilocybin in mushroom extracts using high-performance liquid chromatography with postcolumn chemiluminescence detection. A number of extraction methods for psilocin and psilocybin in hallucinogenic mushrooms were investigated, with a simple methanolic extraction being found to be most effective. Psilocin and psilocybin were extracted from a variety of hallucinogenic mushrooms using methanol. The analytes were separated on a C12 column using a (95:5% v/v) methanol:10 mM ammonium formate, pH 3.5 mobile phase with a run time of 5 min. Detection was realized through a dual reagent chemiluminescence detection system of acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II). The chemiluminescence detection system gave improved detectability when compared with UV absorption at 269 nm, with detection limits of 1.2 x 10(-8) and 3.5 x 10(-9) mol/L being obtained for psilocin and psilocybin, respectively. The procedure was applied to the determination of psilocin and psilocybin in three Australian species of hallucinogenic mushroom.

  2. Chemiluminescence behavior of the carbon dots and the reduced state carbon dots

    Energy Technology Data Exchange (ETDEWEB)

    Teng, Ping [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Xie, Jianxin [College of Resources and Environment, Yuxi Normal University, Yuxi, Yunnan 653100 (China); Long, Yijuan; Huang, Xiaoxiao; Zhu, Rui; Wang, Xiliang; Liang, Liping [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Huang, Yuming, E-mail: ymhuang@swu.edu.cn [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Zheng, Huzhi, E-mail: zhenghz@swu.edu.cn [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China)

    2014-02-15

    Potassium permanganate (KMnO{sub 4}) can react with two different carbon nanoparticles, i.e., carbon dots (CDs) and reduced state carbon dots (r-CDs), in a strong acid medium to generate chemiluminescence (CL). Furthermore, the different CL intensities and CL behaviors due to the different surface groups on these two kinds of carbon nanoparticles were confirmed. CL spectra, fluorescence spectra, UV–vis absorption spectra, and electron paramagnanetic resonance spectra were applied to investigate the CL mechanism. The main reaction pathways were proposed as follows: for the CL reaction between CDs and KMnO{sub 4}, the excited states of CDs (CDs{sup ⁎}) and Mn(II) (Mn(II){sup ⁎}) emerged as KMnO{sub 4} could inject holes into CDs, then, the CDs{sup ⁎} and Mn(II){sup ⁎} acted as luminophors to yield CL; in the r-CDs-KMnO{sub 4} system, r-CDs were oxidized by KMnO{sub 4} directly, and CDs{sup ⁎} and Mn(II){sup ⁎} were produced, at the same time, CL occurred. What is more interesting is that the CL intensity of the r-CD system is stronger than that of the CD system, which confirms that functional groups have strong effect on the CL behavior. It inspired us that new carbon nanoparticles with excellent luminous performance can be designed by tuning their surface groups. -- Highlights: • Carbon dots (CDs) and reduced state carbon dots (r-CDs) can react with potassium permanganate (KMnO{sub 4}) in a strong acid to generate chemiluminescence (CL). • With different surface groups, the CL intensity of r-CDs-KMnO{sub 4} system is different from that of CDs-KMnO{sub 4} system. • The CL mechanisms of the two systems were investigated.

  3. Detection of food irradiation with luminescence methods

    International Nuclear Information System (INIS)

    Anderle, H.

    1997-06-01

    Food irradiation is applied as method for the preservation of foods, the prevention of food spoilage and the inhibition of food-borne pathogens. Doses exceeding 10 kGy (10 kJ/kg) are not recommended by the WHO. The different legislation requires methods for the detection and the closimetry of irradiated foods. Among the physical methods based on the radiation-induced changes in inorganic, nonhygroscopic crystalline solids are thermoluminescence (TL), photostimulated luminescence (PSL) and lyoluminescence (LL) measurement. The luminescence methods were tested on natural minerals. Pure quartz, feldspars, calcite, aragonite and dolomite of known origin were irradiated, read out and analyzed to determine the influence of luminescence-activators and deactivators. Carbonate minerals show an orange-red TL easily detectable by blue-sensitive photomultiplier tubes. TIL-inactive carbonate samples may be identified by a lyoluminescence method using the reaction of trapped irradiation-generated charge carriers with the solvent during crystal-lattice breakup. The fine-ground mineral is dissolved in an alkaline complexing agent/chemiluminescence sensitizer/chemiluminescence catalyst (EDTA/luminol/hemin) reagent mixture. The TL and PSL of quartz is too weak to contribute a significant part for the corresponding signals in polymineral dust. Alkali and soda feldspar show intense TL and PSL. The temperature maxima in the TL glow curves allow a clear distinction. PSL does not give this additional information, it suffers from bleaching by ambient light and requires light-protection. Grain disinfestated with low irradiation doses (500 Gy) may not identified by both TL and PSL measurement. The natural TL of feldspar particles may be overlap with the irradiation-induced TL of other minerals. As a routine method, irradiated spices are identified with TL measurement. The dust particles have to be enriched by heavy-liquid flotation and centrifugation. The PSL method allows a clear

  4. Neutrophil Leukocyte: Combustive Microbicidal Action and Chemiluminescence

    Directory of Open Access Journals (Sweden)

    Robert C. Allen

    2015-01-01

    Full Text Available Neutrophil leukocytes protect against a varied and complex array of microbes by providing microbicidal action that is simple, potent, and focused. Neutrophils provide such action via redox reactions that change the frontier orbitals of oxygen (O2 facilitating combustion. The spin conservation rules define the symmetry barrier that prevents direct reaction of diradical O2 with nonradical molecules, explaining why combustion is not spontaneous. In burning, the spin barrier is overcome when energy causes homolytic bond cleavage producing radicals capable of reacting with diradical O2 to yield oxygenated radical products that further participate in reactive propagation. Neutrophil mediated combustion is by a different pathway. Changing the spin quantum state of O2 removes the symmetry restriction to reaction. Electronically excited singlet molecular oxygen (O2*1 is a potent electrophilic reactant with a finite lifetime that restricts its radius of reactivity and focuses combustive action on the target microbe. The resulting exergonic dioxygenation reactions produce electronically excited carbonyls that relax by light emission, that is, chemiluminescence. This overview of neutrophil combustive microbicidal action takes the perspectives of spin conservation and bosonic-fermionic frontier orbital considerations. The necessary principles of particle physics and quantum mechanics are developed and integrated into a fundamental explanation of neutrophil microbicidal metabolism.

  5. Evaluation of silicon-chemiluminescence monitoring as a novel method for atomic fluorine determination and end point detection in plasma etch systems

    NARCIS (Netherlands)

    Zijlstra, P.A.; Beenakker, C.I.M.

    1981-01-01

    Optical methods for the detection of atomic fluorine in plasma etch systems are discussed and an experimental comparison is made between detection by optical emission and by a novel method based on the chemiluminescence from solid silicon in the presence of atomic fluorine. Although both methods

  6. Determination of ethanol using permanganate-CdS quantum dot chemiluminescence system.

    Science.gov (United States)

    Abolhasani, Jafar; Hassanzadeh, Javad

    2015-08-01

    A novel and highly sensitive chemiluminescence (CL) method for the determination of ethanol was developed based on the CdS quantum dots (QDs)-permanganate system. It was found that KMnO4 could directly oxidize CdS QDs in acidic media resulting in relatively high CL emission. A possible mechanism was proposed for this reaction based on UV/Vis absorption, fluorescence and the generated CL emission spectra. However, it was observed that ethanol had a remarkable inhibition effect on this system. This effect was exploited in the determination of ethanol within the concentration range 12-300 µg/L, with detection at 4.3 µg/L. In order to evaluate the capability of presented method, it was satisfactorily utilized in the determination of alcohol in real samples. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Possibility of determination of the level of antioxidants in human body using spectroscopic methods

    International Nuclear Information System (INIS)

    Timofeeva, E; Gorbunova, E

    2016-01-01

    In this work, the processes of antioxidant defence against aggressive free radicals in human body were investigated theoretically; and the existing methods of diagnosis of oxidative stress and disturbance of antioxidant activity were reviewed. Also, the kinetics of free radical reactions in the oxidation of luminol and interaction antioxidants (such as chlorophyll in the multicomponent system of plant's leaves and ubiquinone) with the UV radiation were investigated experimentally by spectroscopic method. The results showed that this method is effective for recording the luminescence of antioxidants, free radicals, chemiluminescent reactions and fluorescence. In addition these results reveal new opportunities for the study of the antioxidant activity and antioxidant balance in a multicomponent system by allocating features of the individual components in spectral composition. A creation of quality control method for drugs, that are required for oxidative stress diagnosis, is a promising direction in the development of given work. (paper)

  8. Superoxide scavenging activity of pirfenidone-iron complex

    International Nuclear Information System (INIS)

    Mitani, Yoshihiro; Sato, Keizo; Muramoto, Yosuke; Karakawa, Tomohiro; Kitamado, Masataka; Iwanaga, Tatsuya; Nabeshima, Tetsuji; Maruyama, Kumiko; Nakagawa, Kazuko; Ishida, Kazuhiko; Sasamoto, Kazumi

    2008-01-01

    Pirfenidone (PFD) is focused on a new anti-fibrotic drug, which can minimize lung fibrosis etc. We evaluated the superoxide (O 2 ·- ) scavenging activities of PFD and the PFD-iron complex by electron spin resonance (ESR) spectroscopy, luminol-dependent chemiluminescence assay, and cytochrome c reduction assay. Firstly, we confirmed that the PFD-iron complex was formed by mixing iron chloride with threefold molar PFD, and the complex was stable in distillated water and ethanol. Secondary, the PFD-iron complex reduced the amount of O 2 ·- produced by xanthine oxidase/hypoxanthine without inhibiting the enzyme activity. Thirdly, it also reduced the amount of O 2 ·- released from phorbor ester-stimulated human neutrophils. PFD alone showed few such effects. These results suggest the possibility that the O 2 ·- scavenging effect of the PFD-iron complex contributes to the anti-fibrotic action of PFD used for treating idiopathic pulmonary fibrosis

  9. Detection of pyrrolizidine alkaloids using flow analysis with both acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Gorman, Bree A. [School of Biological and Chemical Sciences, Deakin University, Geelong, Vic. 3217 (Australia); Barnett, Neil W. [School of Biological and Chemical Sciences, Deakin University, Geelong, Vic. 3217 (Australia)]. E-mail: barnie@deakin.edu.au; Bos, Richard [School of Biological and Chemical Sciences, Deakin University, Geelong, Vic. 3217 (Australia)

    2005-06-13

    For the first time, analytically useful chemiluminescence was elicited from the reactions of the pyrrolizidine alkaloids. Heliotrine, retronecine, supinine, monocrotaline and echinatine N-oxide yielded chemiluminescence upon reaction with tris(2,2'-bipyridyl)ruthenium(II) whilst lasiocarpine, its N-oxide and supinine elicited light upon reaction with acidic potassium permanganate. Detection limits for heliotrine were 1.25 x 10{sup -7} M and 9 x 10{sup -9} M for tris(2,2'-bipyridyl)ruthenium(III) perchlorate with flow injection analysis (FIA) and the silica-immobilised reagent (4-[4-(dichloromethylsilanyl)-butyl]-4'-methyl-2,2'-bipyridine)bis (2,2'-bipyridyl)ruthenium(II) with sequential injection analysis (SIA), respectively. Lasiocarpine was detectable at 1.4 x 10{sup -7} M using acidic potassium permanganate with FIA. Additionally, the silica-immobilised reagent was optimised with respect to the oxidant (ammonium ceric nitrate) concentration and the aspiration times which afforded a detection limit for codeine of 5 x 10{sup -10} M using SIA.

  10. Chemiluminescence-based multivariate sensing of local equivalence ratios in premixed atmospheric methane-air flames

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, Markandey M.; Krishnan, Sundar R.; Srinivasan, Kalyan K.; Yueh, Fang-Yu; Singh, Jagdish P.

    2011-09-07

    Chemiluminescence emissions from OH*, CH*, C2, and CO2 formed within the reaction zone of premixed flames depend upon the fuel-air equivalence ratio in the burning mixture. In the present paper, a new partial least square regression (PLS-R) based multivariate sensing methodology is investigated and compared with an OH*/CH* intensity ratio-based calibration model for sensing equivalence ratio in atmospheric methane-air premixed flames. Five replications of spectral data at nine different equivalence ratios ranging from 0.73 to 1.48 were used in the calibration of both models. During model development, the PLS-R model was initially validated with the calibration data set using the leave-one-out cross validation technique. Since the PLS-R model used the entire raw spectral intensities, it did not need the nonlinear background subtraction of CO2 emission that is required for typical OH*/CH* intensity ratio calibrations. An unbiased spectral data set (not used in the PLS-R model development), for 28 different equivalence ratio conditions ranging from 0.71 to 1.67, was used to predict equivalence ratios using the PLS-R and the intensity ratio calibration models. It was found that the equivalence ratios predicted with the PLS-R based multivariate calibration model matched the experimentally measured equivalence ratios within 7%; whereas, the OH*/CH* intensity ratio calibration grossly underpredicted equivalence ratios in comparison to measured equivalence ratios, especially under rich conditions ( > 1.2). The practical implications of the chemiluminescence-based multivariate equivalence ratio sensing methodology are also discussed.

  11. Suitability of thermoluminescence, chemiluminescence, ESR and viscosity measurements as detection method for the irradiation of medicinal herbs

    International Nuclear Information System (INIS)

    Schuettler, C.; Gebhardt, G.; Stock, A.; Helle, N.; Boegl, K.W.

    1993-01-01

    Chemiluminescence, electron spin resonance, thermoluminescence and viscosity measurements have been investigated for their suitability as detection method for the irradiation of the medicinal herbs anise seeds (anisi fructus), valerian roots (valerianae radix), redberry leaves (uvae ursi folium), birch leaves (betulae folium), greek hay seeds (foenugraeci semen), cayenne pepper (capsici fructus acer), black-aldertee bark (frangulae cortex), fennel fruits (feoniculi fructus), rose hip shells (cynosbati fructus), coltsfoot (farfarae folium), acorus roots (calami rhizoma), chamomile flowers (matricariae flos), caraway (carvi fructus), lavender flowers (lavandulae flos), linseed (lini semen), lime tree flowers (tiliae flos), St. Mary's thistle fruit (cardui mariae herba), lemon balm (melissae folium), java tea (orthosiphonis folium), peppermint (menthae piperitae folium), sage leaves (salviae folium), scouring rush (equiseti herba), senna leaves (sennae folium), plantain herbs (plantaginis lanceolata herba), thyme herbs (thymi herba), juniper berries (juniperi fructus), hawthorne herbs (crataegi folium), wheat starch (amylum tritici) and wormwood (absinthii herba). Depending on the herbs, the methods used were more or less suitable. Chemiluminescence measurements showed the smallest differences between untreated and irradiated samples whereas thermoluminescence measurements on isolated minerals from the vegetable drugs gave better results. In some herbs radiation-specific radicals could be identified by ESR spectroscopy. Viscosity measurement is suitable for some herbs as fast and inexpensive method for screening. (orig.) [de

  12. Can irradiation of spices be detected by chemiluminescence?

    International Nuclear Information System (INIS)

    Delincee, H.

    1987-01-01

    Chemiluminescence (CL) has been reported as a reliable identification measure for radiation processed spices. Luminescence intensities, however, vary considerably from one spice to another. Even for one spice from various producers, different results have been obtained. One of the main drawbacks of CL is its poor reproducibility. Attempts to reduce the variability have so far been unsuccessful. Since the CL response is frequently a non-monotone function of dose, the applied radiation dose cannot be estimated unequivocally. Attempts to establish an internal standard were not successful. A further hindrance for dose estimation is the fading of luminescence with storage time. In the case of juniper berries 50-78% of the irradiated samples could be identified correctly, depending on selection criteria. With marjoram, however, only one out of five samples could be identified. Variations in the radiation conditions did not change CL. However, an increase in CL was also noted in some experiments with fumigated spices. The CL measurement as a single tool for identifying radiation processed spices seems at the moment not to fulfil the requirements of reliable detection. A combination of methods may eventually allow identification of irradiated spices. (orig./MG) [de

  13. Can irradiation of spices be detected by chemiluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Delincee, H

    1987-01-01

    Chemiluminescence (CL) has been reported as a reliable identification measure for radiation processed spices. Luminescence intensities, however, vary considerably from one spice to another. Even for one spice from various producers, different results have been obtained. One of the main drawbacks of CL is its poor reproducibility. Attempts to reduce the variability have so far been unsuccessful. Since the CL response is frequently a non-monotone function of dose, the applied radiation dose cannot be estimated unequivocally. Attempts to establish an internal standard were not successful. A further hindrance for dose estimation is the fading of luminescence with storage time. In the case of juniper berries 50-78% of the irradiated samples could be identified correctly, depending on selection criteria. With marjoram, however, only one out of five samples could be identified. Variations in the radiation conditions did not change CL. However, an increase in CL was also noted in some experiments with fumigated spices. The CL measurement as a single tool for identifying radiation processed spices seems at the moment not to fulfil the requirements of reliable detection. A combination of methods may eventually allow identification of irradiated spices.

  14. A sensitive and selective chemiluminescence sensor for the determination of dopamine based on silanized magnetic graphene oxide-molecularly imprinted polymer.

    Science.gov (United States)

    Duan, Huimin; Li, Leilei; Wang, Xiaojiao; Wang, Yanhui; Li, Jianbo; Luo, Chuannan

    2015-03-15

    Based on silanized magnetic graphene oxide-molecularly imprinted polymer (Si-MG-MIP), a sensitive and selective chemiluminescence sensor for dopamine measurement was developed. Si-MG-MIP, in which silanes was introduced to improve the mass transfer, graphene oxide was employed to improve absorption capacity, Fe3O4 nanoparticles were applied for separation easily and molecularly imprinted polymer was used to improve selectivity, demonstrated the advantages of the sensor. All the composites were confirmed by SEM, TEM, XRD and FTIR. Under the optimal conditions of chemiluminescence, dopamine could be assayed in the range of 8.0-200.0 ng/mL with a correlation coefficient of linear regression of 0.9970. The detection limit was 1.5 ng/mL (3δ) and the precision for 11 replicate detections of 80.0 ng/mL dopamine was 3.4% (RSD). When the sensor was applied in determining dopamine in actual samples, recovery ranged from 94% to 110%, which revealed that the results were satisfactory. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. A novel chemiluminescence system with diperiodatonickelate (IV) for the determination of adrenaline

    Science.gov (United States)

    Yang, Chunyan; Chen, Fubin; Chang, Ziqiang; Sun, Yonghua; Zhang, Zhujun

    2014-03-01

    A novel chemiluminescence (CL) system with diperiodatonickelate (IV) (DPN) was developed for the determination of adrenaline for the first time. The possible CL emission mechanism was briefly discussed by comparing the fluorescence emission spectra with CL spectra. Under the optimum conditions, the relative CL intensity was linear over the concentration of AD ranging from 1.0 × 10-7 to 1.0 × 10-5 g mL-1 with a detection limit of 4.0 × 10-8 g mL-1 (3σ). And the relative standard deviation was 3.7% for 2.0 × 10-6 g mL-1 AD (n = 11). The developed method has been successfully applied to the determination of AD in pharmaceutical preparations.

  16. The effect of lipid peroxidation products on reactive oxygen species formation and nitric oxide production in lipopolysaccharide-stimulated RAW 264.7 macrophages.

    Science.gov (United States)

    Ambrozova, Gabriela; Pekarova, Michaela; Lojek, Antonin

    2011-02-01

    Lipid peroxidation induced by oxidants leads to the formation of highly reactive metabolites. These can affect various immune functions, including reactive oxygen species (ROS) and nitric oxide (NO) production. The aim of the present study was to investigate the effects of lipid peroxidation products (LPPs) - acrolein, 4-hydroxynonenal, and malondialdehyde - on ROS and NO production in RAW 264.7 macrophages and to compare these effects with the cytotoxic properties of LPPs. Macrophages were stimulated with lipopolysaccharide (0.1 μg/ml) and treated with selected LPPs (concentration range: 0.1-100 μM). ATP test, luminol-enhanced chemiluminescence, Griess reaction, Western blotting analysis, amperometric and total peroxyl radical-trapping antioxidant parameter assay were used for determining the LPPs cytotoxicity, ROS and NO production, inducible nitric oxide synthase expression, NO scavenging, and antioxidant properties of LPPs, respectively. Our study shows that the cytotoxic action of acrolein and 4-hydroxynonenal works in a dose- and time-dependent manner. Further, our results imply that acrolein, 4-hydroxynonenal, and malondialdehyde can inhibit, to a different degree, ROS and NO production in stimulated macrophages, partially independently of their toxic effect. Also, changes in enzymatic pathways (especially NADPH-oxidase and nitric oxide synthase inhibition) and NO scavenging properties are included in the downregulation of reactive species formation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Chemiluminescence determination of streptomycin in pharmaceutical preparation and its application to pharmacokinetic study by a flow injection analysis assembly

    Science.gov (United States)

    Du, Bin; Li, Hongyan; Jin, Jianwen; Wang, Tiantian; Li, Yang; Shen, Guopeng; Li, Xiaotian

    2013-11-01

    A novel and rapid method for the determination of streptomycin has been established by chemiluminescence (CL) based on significant intensity enhancement of streptomycin on the weak CL of N-bromosuccinimide (NBS) and eosin in alkaline medium. The method is simple, rapid and effective to determine streptomycin in the range of 8.0 × 10-9-1.0 × 10-6 g mL-1 with a determination limit of 2.25 × 10-9 g mL-1. The relative standard deviation is 1.95% for the determination of 2.0 × 10-7 g mL-1 streptomycin (n = 11). The pharmacokinetics of streptomycin in plasma of rat coincides with the two-compartment open model. The T1/2α, T1/2β, CL/F, AUC(0-t), MRT, Tmax and Cmax were 18.83 ± 1.24 min, 82.14 ± 3.07 min, 0.0026 ± 0.0011 L kg-1 min-1, 36044.50 ± 105.02 mg min-1 L-1, 92.29 ± 8.21 min, 21.63 ± 1.26 min and 375.61 ± 8.50 μg mL-1, respectively. There was no significant difference between the results obtained by CL and HPLC. The FI-CL method can be used to determine streptomycin in pharmaceutical preparation and biological samples. The established method is simple, rapid and sensitive without expensive instruments. The possible enhancement mechanism was also investigated.

  18. Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system

    Directory of Open Access Journals (Sweden)

    Li-Juan Wang

    2011-02-01

    Full Text Available A novel flow injection chemiluminescence (CL method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4, and Na2SO3 in acid media. The CL intensity of KMnO4-Na2SO3 was greatly enhaneed in the presence of loxoprofen and naproxen. The mechanism of the CL reaction was studied by the kinetic proecss and UV-vis absorption and the conditions were optimized. Under optimized conditions, the CL intensity was linear with loxoprofen and naproxen concentration in the range of 7.0 × 10−8 – 1.0 × 10−5 g/mL and 2.0 × 10−7 – 4.0 × 10−6 g/mL with the detection limit of 2.0 × 10−8 g/mL and 3.0 × 10−8 g/mL (S/N = 3, respectively. Thc relative standard deviations were 2.39% and 1.37% for 5.0 × 10−7 g/mL naproxen and 5.0 × 10−7 g/mL loxoprofen (n = 10, respectively. The proposed method was satisfactorily applied to thc determination of loxoprofen and naproxen in pharmaceutical preparations. Keywords: chemiluminescence, KMnO4, loxoprofen, naproxen

  19. Development of nanobody-based flow injection chemiluminescence immunoassay for sensitive detection of human prealbumin.

    Science.gov (United States)

    Ma, Lei; Sun, Yanyan; Kang, Xuejun; Wan, Yakun

    2014-11-15

    Nanobodies, derived from camelid heavy-chain antibodies, have novel and impactful applications in clinical diagnostics. Our objective is to develop a nanobody-based chemiluminescence immunoassay for sensitive detection of human prealbumin (PA). In this context, a phage display nanobody library is constructed via immunizing dromedary camel with human prealbumin. Three nanobodies have been identified by five successive bio-panning steps. Based on their high expression level and good affinity, two out of three are chosen for further study. Magnetic beads (MBs) were functionalized with PEI by acylamide bond formed between the carboxyl group on the surface of the MB. Then, an anti-PA nanobody (Nb1) can be effectively immobilized onto the surface of the functionalized MB using glutaradehyde as the link. The modified MBs with Nb1 can specifically capture the target PA and reacted with silica nanoparticles with co-immobilized HRP and anti-PA nanobody (Nb2). The concentration of PA was detected by flow injection chemiluminescence. When using MB/PEI as the carrier of anti-PA Nb1, the CL signal significantly increased to 4-fold compared with the signal using MB without PEI modification. The CL signal was further amplified to 5-fold when Si/Nb2 was used as the signal probe. Under optimized conditions, the present immunoassay exhibited a wide quantitative range from 0.05 to 1000 μg L(-1) with a detection limit of 0.01 μg L(-1). The sensitivity of the proposed immunoassay offers great promises in providing a sensitive, specific, time saving, and potential method for detecting PA in clinical settings. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. High-sensitivity chemiluminescence immunoassays for detection of growth hormone doping in sports.

    Science.gov (United States)

    Bidlingmaier, Martin; Suhr, Jennifer; Ernst, Andrea; Wu, Zida; Keller, Alexandra; Strasburger, Christian J; Bergmann, Andreas

    2009-03-01

    Recombinant human growth hormone (rhGH) is abused in sports, but adequate routine doping tests are lacking. Analysis of serum hGH isoform composition has been shown to be effective in detecting rhGH doping. We developed and validated selective immunoassays for isoform analysis with potential utility for screening and confirmation in doping tests. Monoclonal antibodies with preference for pituitary hGH (phGH) or rhGH were used to establish 2 pairs of sandwich-type chemiluminescence assays with differential recognition of rhGH (recA and recB) and phGH (pitA and pitB). We analyzed specimens from volunteers before and after administration of rhGH and calculated ratios between the respective rec- and pit-assay results. Functional sensitivities were <0.05 microg/L, with intra- and interassay imprecision < or =8.4% and < or =13.7%, respectively. In 2 independent cohorts of healthy subjects, rec/pit ratios (median range) were 0.84 (0.09-1.32)/0.81 (0.27-1.21) (recA/pitA) and 0.68 (0.08-1.20)/0.80 (0.25-1.36) (recB/pitB), with no sex difference. In 20 recreational athletes, ratios (median SD) increased after a single injection of rhGH, reaching 350% (73%) (recA/pitA) and 400% (93%) (recB/pitB) of baseline ratios. At a moderate dose (0.033 mg/kg), mean recA/pitA and recB/pitB ratios remained significantly increased for 18 h (men) and 26 h (women). After high-dose rhGH (0.083 mg/kg), mean rec/pit ratios remained increased for 32 h (recA/pitA) and 34 h (recB/pitB) in men and were still increased after 36 h in women. Using sensitive chemiluminescence assays with preferential recognition of phGH or rhGH, detection of a single injection of rhGH was possible for up to 36 h.

  1. Evaluation of poly(lactic-co-glycolic acid) and poly(DL-lactide-co-ε-caprolactone) electrospun fibers for the treatment of HSV-2 infection

    Energy Technology Data Exchange (ETDEWEB)

    Aniagyei, Stella E.; Sims, Lee B. [Department of Bioengineering, University of Louisville, Louisville, KY 40202 (United States); Malik, Danial A. [Department of Pharmacology and Toxicology, University of Louisville, Louisville, KY 40202 (United States); Tyo, Kevin M. [Department of Pharmacology and Toxicology, University of Louisville, Louisville, KY 40202 (United States); Center for Predictive Medicine, University of Louisville, Louisville, KY 40202 (United States); Curry, Keegan C. [Department of Bioengineering, University of Louisville, Louisville, KY 40202 (United States); Kim, Woihwan [Department of Medicine, University of Louisville, Louisville, KY 40202 (United States); Hodge, Daniel A. [Department of Bioengineering, University of Louisville, Louisville, KY 40202 (United States); Duan, Jinghua [Department of Bioengineering, University of Louisville, Louisville, KY 40202 (United States); Center for Predictive Medicine, University of Louisville, Louisville, KY 40202 (United States); Steinbach-Rankins, Jill M., E-mail: jill.steinbach@louisville.edu [Department of Bioengineering, University of Louisville, Louisville, KY 40202 (United States); Department of Pharmacology and Toxicology, University of Louisville, Louisville, KY 40202 (United States); Department of Microbiology and Immunology, University of Louisville, Louisville, KY 40202 (United States); Center for Predictive Medicine, University of Louisville, Louisville, KY 40202 (United States)

    2017-03-01

    More diverse multipurpose prevention technologies are urgently needed to provide localized, topical pre-exposure prophylaxis against sexually transmitted infections (STIs). In this work, we established the foundation for a multipurpose platform, in the form of polymeric electrospun fibers (EFs), to physicochemically treat herpes simplex virus 2 (HSV-2) infection. To initiate this study, we fabricated different formulations of poly(lactic-co-glycolic acid) (PLGA) and poly(DL-lactide-co-ε-caprolactone) (PLCL) EFs that encapsulate Acyclovir (ACV), to treat HSV-2 infection in vitro. Our goals were to assess the release and efficacy differences provided by these two different biodegradable polymers, and to determine how differing concentrations of ACV affected fiber efficacy against HSV-2 infection and the safety of each platform in vitro. Each formulation of PLGA and PLCL EFs exhibited high encapsulation efficiency of ACV, sustained-delivery of ACV through one month, and in vitro biocompatibility at the highest doses of EFs tested. Additionally, all EF formulations provided complete and efficacious protection against HSV-2 infection in vitro, regardless of the timeframe of collected fiber eluates tested. This work demonstrates the potential for PLGA and PLCL EFs as delivery platforms against HSV-2, and indicates that these delivery vehicles may be expanded upon to provide protection against other sexually transmitted infections. - Highlights: • PLGA and PLCL EFs exhibit sustained-delivery of ACV through one month. • EFs exhibit high ACV encapsulation efficiency and in vitro biocompatibility. • EFs serve as both physical and chemical barriers to HSV-2 infection. • Potent in vitro efficacy is provided against HSV-2 infection for all formulations. • HSV-2 protection is independent of administration times within one month.

  2. Evaluation of poly(lactic-co-glycolic acid) and poly(DL-lactide-co-ε-caprolactone) electrospun fibers for the treatment of HSV-2 infection

    International Nuclear Information System (INIS)

    Aniagyei, Stella E.; Sims, Lee B.; Malik, Danial A.; Tyo, Kevin M.; Curry, Keegan C.; Kim, Woihwan; Hodge, Daniel A.; Duan, Jinghua; Steinbach-Rankins, Jill M.

    2017-01-01

    More diverse multipurpose prevention technologies are urgently needed to provide localized, topical pre-exposure prophylaxis against sexually transmitted infections (STIs). In this work, we established the foundation for a multipurpose platform, in the form of polymeric electrospun fibers (EFs), to physicochemically treat herpes simplex virus 2 (HSV-2) infection. To initiate this study, we fabricated different formulations of poly(lactic-co-glycolic acid) (PLGA) and poly(DL-lactide-co-ε-caprolactone) (PLCL) EFs that encapsulate Acyclovir (ACV), to treat HSV-2 infection in vitro. Our goals were to assess the release and efficacy differences provided by these two different biodegradable polymers, and to determine how differing concentrations of ACV affected fiber efficacy against HSV-2 infection and the safety of each platform in vitro. Each formulation of PLGA and PLCL EFs exhibited high encapsulation efficiency of ACV, sustained-delivery of ACV through one month, and in vitro biocompatibility at the highest doses of EFs tested. Additionally, all EF formulations provided complete and efficacious protection against HSV-2 infection in vitro, regardless of the timeframe of collected fiber eluates tested. This work demonstrates the potential for PLGA and PLCL EFs as delivery platforms against HSV-2, and indicates that these delivery vehicles may be expanded upon to provide protection against other sexually transmitted infections. - Highlights: • PLGA and PLCL EFs exhibit sustained-delivery of ACV through one month. • EFs exhibit high ACV encapsulation efficiency and in vitro biocompatibility. • EFs serve as both physical and chemical barriers to HSV-2 infection. • Potent in vitro efficacy is provided against HSV-2 infection for all formulations. • HSV-2 protection is independent of administration times within one month.

  3. Biofunctionalization of aqueous dispersed, alumina membrane-templated polymer nanorods for use in enzymatic chemiluminescence assays.

    Science.gov (United States)

    Mark, Sonny S; Stolper, Samuel I; Baratti, Carla; Park, Jason Y; Kricka, Larry J

    2008-09-01

    The noncovalent immobilization of alkaline phosphatase (ALP) onto aqueous dispersed nylon 6 nanorods ( approximately 310 nm mean diameter; approximately 6 microm mean length) prepared by anodic aluminum oxide (AAO) membrane templating was studied. Using multi-stacked layer-by-layer (LBL) assembly with the cationic quaternary ammonium polymer Sapphire II , the amount of ALP enzyme loaded onto the polymer nanostructures was found to be 115+/-7 microg mg(-1) nanorod. The biofunctionalized nanorods were also characterized for their chemiluminescent activity with the dioxetane substrate, CSPD . The results indicate that the kinetic parameters, K(m) and V(max), for the catalytic activity of the nanostructure-bound ALP enzyme are different from those of soluble ('free') ALP. While the K(m) value was measured to be 156 microM for free ALP, the apparent K(m) value determined for the LBL-immobilized ALP is approximately 20% lower (122 microM). Furthermore, despite the relatively high enzyme loading capacity of the nanorods, the specific activity of the bound ALP enzyme was found to be almost nine times lower than that measured for free ALP. Finally, additional experiments revealed that the catalytic activities of both free ALP and nanorod-conjugated ALP are affected similarly by changes in pH, with optimal performance levels occurring under conditions of pH 9.5. To the best of our knowledge, this study represents the first report examining the preparation of aqueous dispersed, AAO-templated polymer nanorods for potential application as enzyme scaffolds in chemiluminescent-based assay systems.

  4. Hot electron-induced time-resolved electrogenerated chemiluminescence of a europium(III) label in fully aqueous solutions

    International Nuclear Information System (INIS)

    Jiang, Q.; Hakansson, M.; Spehar, A.-M.; Ahonen, J.; Ala-Kleme, T.; Kulmala, S.

    2006-01-01

    Time-resolved electrogenerated chemiluminescence of multidentate phenolic Eu(III) chelates were studied in aqueous solution. 2,6-bis[N,N-bis(carboxymethyl)-aminomethyl]-4-benzoylphenol forms a photoluminescent and electrochemiluminescent Eu(III) chelate, whereas 2,6-bis[N,N-bis(carboxymethyl)-aminomethyl]-4-methyl phenol-chelated Eu(III) turned out to be not luminescent at all. The importance of the redox properties of both the ground and the excited states of the ligands and the central ion is shown. The former chelate shows relatively weak ECL at an oxide-covered aluminum electrode but the ECL intensity can be strongly enhanced by the addition of peroxodisulfate ions. In the presence of 1 mM peroxodisulfate ions the ECL lifetime of this chelate is 0.94 ms, thus easily allowing time-resolved detection of the chelate. This chelate can be conjugated to antibodies by thioureido linkage and used as an electrochemiluminescent label in immunoassays as a marker which displays long-lived luminescence in the red end of the optical spectrum. The present ECL is mainly based on the ligand sensitized redox excitation of the chelate by analogous pathways to those known from the studies of aromatic Tb(III) chelates but the energy transfer from the emission centers of the aluminum oxide film can also have minor contribution to the excitation of the label

  5. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    Science.gov (United States)

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  6. Visible light assisted photodegradation of halocarbons on the dye modified TiO{sub 2} surface using visible light

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, Debabrata; Dasgupta, Shimanti [Chemistry Section, Central Mechanical Engineering Research Institute, Durgapur 713209 (India); N Rao, Nageswar [Wastewater Technology Division, National Environmental Engineering Research Institute, Nagpur 400020 (India)

    2006-05-05

    Visible light assisted photodegradation of various halocarbons, viz. chloro-phenols, trichloroethylene, 1,2-dichloroethane and 1,4-dichlorobenzene, has been achieved on the surface of dye-modified TiO{sub 2} semiconductor. Thionine, eosinY, rhodamineB, methyleneblue, nileblueA and safranineO were used for the modification of TiO{sub 2} semiconductor photocatalyst. After 5h of irradiation with a 150W Xenon lamp, over 55-72% degradation of pollutants has been achieved. A working mechanism involving excitation of surface adsorbed dye, followed by charge injection into the TiO{sub 2} conduction band and formation of reactive {sup *}O{sub 2}{sup -}/{sup *}HO{sub 2} radicals, is proposed for the degradation of the enlisted organics to carbon dioxide. Efficacy of the photocatalytic system towards halocarbon degradation has been discussed in regard to excited state redox properties of the dyes selected for this study. Formation of {sup *}O{sub 2}{sup -} radical has been substantiated by using a chemiluminescent probe luminol. (author)

  7. Development of a Capillary-driven, Microfluidic, Nucleic Acid Biosensor

    Directory of Open Access Journals (Sweden)

    Fei HE

    2011-12-01

    Full Text Available An ideal point-of-care device would incorporate the simplicity and reliability of a lateral flow assay with a microfluidic device. Our system consists of self-priming microfluidics with sealed conjugate pads of reagent delivery and an absorbent pad for additional fluid draw. Using poly (methyl methacrylate (PMMA as a substrate, we have developed a single-step surface modification method which allows strong capillary flow within a sealed microchannel. Conjugate pads within the device held trapped complex consisting of the magnetic beads and nucleic-acid-probe-conjugated horseradish peroxidase (HRP. Magnetic beads were released when sample entered the chamber and hybridized with the complex. The complex was immobilized over a magnet while a luminol co-reactant stream containing H2O2 was merged with the channel. A plate reader was able to quantify the chemiluminescence signal. This new format of biosensor will allow for a smaller and more sensitive biosensor, as well as commercial-scale manufacturing and low materials cost.

  8. Sonochemical cleaning efficiencies in dental instruments

    Science.gov (United States)

    Tiong, T. Joyce; Walmsley, A. Damien; Price, Gareth J.

    2012-05-01

    Ultrasound has been widely used for cleaning purposes in a variety of situations, including in dental practice. Cleaning is achieved through a combination of acoustically driven streaming effects and sonochemical effects arising from the production of inertial cavitation in a liquid. In our work, various dental instruments used for endodontic (root canal) treatment have been evaluated for their efficiency in producing sonochemical effects in an in-vitro cleaning environment. The areas where cavitation was produced were mapped by monitoring chemiluminescence from luminol solutions and this was correlated with their cleaning efficiencies - assessed by the ability to bleach a dye, to form an emulsion by mixing immiscible components and also to remove ink from a glass surface. The results showed good correlation (Pearson's coefficient > 0.9) between the cavitation and cleaning efficiencies, suggesting that the former plays an important role in cleaning. The methods developed and the results will be beneficial in endodontics research in order to optimise future root canal instruments and treatments.

  9. Sample Handling and Chemical Kinetics in an Acoustically Levitated Drop Microreactor

    Science.gov (United States)

    2009-01-01

    Accurate measurement of enzyme kinetics is an essential part of understanding the mechanisms of biochemical reactions. The typical means of studying such systems use stirred cuvettes, stopped-flow apparatus, microfluidic systems, or other small sample containers. These methods may prove to be problematic if reactants or products adsorb to or react with the container’s surface. As an alternative approach, we have developed an acoustically-levitated drop reactor eventually intended to study enzyme-catalyzed reaction kinetics related to free radical and oxidative stress chemistry. Microliter-scale droplet generation, reactant introduction, maintenance, and fluid removal are all important aspects in conducting reactions in a levitated drop. A three capillary bundle system has been developed to address these needs. We report kinetic measurements for both luminol chemiluminescence and the reaction of pyruvate with nicotinamide adenine dinucleotide, catalyzed by lactate dehydrogenase, to demonstrate the feasibility of using a levitated drop in conjunction with the developed capillary sample handling system as a microreactor. PMID:19769373

  10. Determination of fluvoxamine maleate in human urine and human serum using alkaline KMnO4 -rhodamine B chemiluminescence.

    Science.gov (United States)

    Yang, Dongqin; He, Yanyan; Chen, Funan

    2017-09-01

    The flow-injection chemiluminescence (FI-CL) behavior of a gold nanocluster (Au NC)-enhanced rhodamine B-KMnO 4 system was studied under alkaline conditions for the first time. In the present study, the as-prepared bovine serum albumin-stabilized Au NCs showed excellent stability and reproducibility. The addition of trace levels of fluvoxamine maleate (Flu) led to an obvious decline in CL intensity in the rhodamine B-KMnO 4 -Au NCs system, which could be used for quantitative detection of Flu. Under optimized conditions, the proposed CL system exhibited a favorable analytical performance for Flu determination in the range 2 to 100 μg ml -1 . The detection limit for Flu measurement was 0.021 μg ml -1 . Moreover, this newly developed system revealed outstanding selectivity for Flu detection when compared with a multitude of other species, such as the usual ions, uric acid and a section of hydroxy compounds. Additionally, CL spectra, UV-visible spectroscopes and fluorescence spectra were measured in order to determine the possible reaction mechanism. This approach could be used to detect Flu in human urine and human serum samples with the desired recoveries and could have promising application under physiological conditions. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Recent advances in chemiluminescence detection coupled with capillary electrophoresis and microchip capillary electrophoresis.

    Science.gov (United States)

    Liu, Yuxuan; Huang, Xiangyi; Ren, Jicun

    2016-01-01

    CE is an ideal analytical method for extremely volume-limited biological microenvironments. However, the small injection volume makes it a challenge to achieve highly sensitive detection. Chemiluminescence (CL) detection is characterized by providing low background with excellent sensitivity because of requiring no light source. The coupling of CL with CE and MCE has become a powerful analytical method. So far, this method has been widely applied to chemical analysis, bioassay, drug analysis, and environment analysis. In this review, we first introduce some developments for CE-CL and MCE-CL systems, and then put the emphasis on the applications in the last 10 years. Finally, we discuss the future prospects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Chemiluminescence determination of tetracyclines using Fenton system in the presence europium(III) ions

    International Nuclear Information System (INIS)

    Kaczmarek, Malgorzata; Lis, Stefan

    2009-01-01

    A new simple chemiluminescent method for the determination of chlortetracycline (Chlor-TC), oxytetracycline (Oxy-TC) and doxycycline (Doxy-TC) is described. This method is based on the europium(III) emission as a result of the energy transfer process from the excited product of the tetracyclines oxidation to the uncomplexed Eu(III). Under the optimum conditions, calibration graphs were obtained for 4 x 10 -7 to 2 x 10 -5 mol L -1 of Chlor-TC; 2 x 10 -7 to 2 x 10 -5 mol L -1 of Oxy-TC and 1 x 10 -7 to 3 x 10 -5 mol L -1 of Doxy-TC. The method was successfully applied to the determination of these drugs in pharmaceutical and veterinary formulation and honey.

  13. Comparative study of B-glucan induced respiratory burst measured by nitroblue tetrazolium assay and real-time luminol-enhanced chemiluminescence assay in common carp (Cyrpinus carpio L.)

    NARCIS (Netherlands)

    Vera-Jimenez, N.I.; Pietretti, D.; Wiegertjes, G.F.; Nielsen, M.E.

    2013-01-01

    The respiratory burst is an important feature of the immune system. The increase in cellular oxygen uptake that marks the initiation of the respiratory burst is followed by the production of reactive oxygen species (ROS) such as superoxide anion and hydrogen peroxide which plays a role in the

  14. A preliminary study of ester oxidation on an aluminum surface using chemiluminescence

    Science.gov (United States)

    Jones, William R., Jr.; Meador, Michael A.; Morales, Wilfredo

    1987-01-01

    The oxidation characteristics of a pure ester (trimethyolpropane triheptanoate) were studied by using a chemiluminescence technique. Tests were run in a thin-film micro-oxidation apparatus with an aluminum alloy catalyst. Conditions included a pure oxygen atmosphere and a temperature range of 176 to 206 C. Results indicated that oxidation of the ester (containing 10 to the minus 3rd power M diphenylanthracene as an intensifier) was accompanied by emission of light. The maximum intensity of light emission (I sub max) was a function of the amount of ester, the concentration of intensifier, and the test temperature. The induction period or the time to reach one-half of maximum intensity (t sub 1/2) was an inverse function of test temperature. Decreases in light emission at the later stages of a test were caused by depletion of the intensifier.

  15. Characterization of Diesel and Gasoline Compression Ignition Combustion in a Rapid Compression-Expansion Machine using OH* Chemiluminescence Imaging

    Science.gov (United States)

    Krishnan, Sundar Rajan; Srinivasan, Kalyan Kumar; Stegmeir, Matthew

    2015-11-01

    Direct-injection compression ignition combustion of diesel and gasoline were studied in a rapid compression-expansion machine (RCEM) using high-speed OH* chemiluminescence imaging. The RCEM (bore = 84 mm, stroke = 110-250 mm) was used to simulate engine-like operating conditions at the start of fuel injection. The fuels were supplied by a high-pressure fuel cart with an air-over-fuel pressure amplification system capable of providing fuel injection pressures up to 2000 bar. A production diesel fuel injector was modified to provide a single fuel spray for both diesel and gasoline operation. Time-resolved combustion pressure in the RCEM was measured using a Kistler piezoelectric pressure transducer mounted on the cylinder head and the instantaneous piston displacement was measured using an inductive linear displacement sensor (0.05 mm resolution). Time-resolved, line-of-sight OH* chemiluminescence images were obtained using a Phantom V611 CMOS camera (20.9 kHz @ 512 x 512 pixel resolution, ~ 48 μs time resolution) coupled with a short wave pass filter (cut-off ~ 348 nm). The instantaneous OH* distributions, which indicate high temperature flame regions within the combustion chamber, were used to discern the characteristic differences between diesel and gasoline compression ignition combustion. The authors gratefully acknowledge facilities support for the present work from the Energy Institute at Mississippi State University.

  16. Identification of gamma-irradiated foodstuffs by chemiluminescence measurements in Taiwan

    Science.gov (United States)

    Ma, Ming-Shia Chang; Chen, Li-Hsiang; Tsai, Zei-Tsan; Fu, Ying-Kai

    In order to establish chemiluminescence (CL) measurements as an identification method for γ-irradiated foodstuffs in Taiwan, ten agricultural products including wheat flour, rice, ginger, potatoes, garlic, onions, red beans, mung beans, soy beans, xanthoxylon seeds and Japanese star anises have been tested to compare CL intensities between untreated samples and samples subject to a 10 kGy γ-irradiation dose. Amongst them, wheat flour is the most eligible product to be identified by CL measurements. The CL intensities of un-irradiated and irradiated flour have shown large differences associated with a significant dose-effect relationship. Effects of three different protein contents of flour, unsieved and sieved (100-200 mesh), the reproducibility and the storage experiment on CL intensities at various doses were investigated in this study. In addition, the white bulb part of onions has shown some CL in irradiated samples. The CL data obtained from the other eight agricultural products have shown large fluctuations and cannot be used to differentiate between irradiated and un-irradiated samples.

  17. Identification of gamma-irradiated foodstuffs by chemiluminescence measurements in Taiwan

    International Nuclear Information System (INIS)

    Mingshia Chang Ma; Lihsiang Chen; Zeitsan Tsai; Yingkai Fu

    1992-01-01

    In order to establish chemiluminescence (CL) measurements as an identification method for γ-irradiated foodstuffs in Taiwan, ten agricultural products including wheat flour, rice, ginger, potatoes, garlic, onions, red beans, mung beans, soy beans, xanthoxylon seeds and Japanese star anises have been tested to compare CL intensities between untreated samples and samples subject to a 10 kGy γ-irradiation dose. Amongst them, wheat flour is the most eligible product to be identified by CL measurements. The CL intensities of un-irradiated and irradiated flour have shown large differences associated with a significant dose-effect relationship. Effects of three different protein contents of flour, unsieved and sieved (100-200 mesh), the reproducibility and the storage experiment on CL intensities at various doses were investigated in this study. In addition, the white bulb part of onions has shown some CL in irradiated samples. The CL data obtained from the other eight agricultural products have shown large fluctuations and cannot be used to differentiate between irradiated and un-irradiated samples. (Author)

  18. Optimization and development of a high-performance liquid chromatography-based one-site immunometric assay with chemiluminescence detection

    International Nuclear Information System (INIS)

    Oates, Matthew R.; Clarke, William; Zimlich, Alden; Hage, David S.

    2002-01-01

    Various practical and theoretical considerations were examined in the creation and optimization of a high-performance liquid chromatography (HPLC)-based one-site immunometric assay. This method used an HPLC analyte analog column and post-column chemiluminescence detection. The specific analyte chosen as the model for this study was L-thyroxine (also known as T 4 ). In this technique, a sample containing thyroxine was first combined with an excess of anti-T 4 antibody Fab fragments that had earlier been conjugated with chemiluminescent acridinium ester labels. After incubation, the mixture was injected onto a column that contained immobilized T 4 . The amount of thyroxine in the original sample was then determined by measuring the labeled Fab fragments that appeared in the non-retained fraction, or the decrease in excess Fab fragments that were bound to and later eluted from the column. Items considered in creating this assay included the preparation of acridinium ester-labeled Fab fragments, the detection of these fragments with a post-column reactor, and the creation of a suitable immobilized analog column for capturing excess labeled Fab fragments. The final method could measure T 4 in standards at clinically-relevant concentrations and provided a response within 1.5 min of sample injection, following a 20-45 min incubation with the labeled Fab fragments. Possible applications of this method include its use in clinical chemistry and the screening of proteomic or combinatorial libraries

  19. Chemiluminescence determination of tetracyclines using Fenton system in the presence europium(III) ions

    Energy Technology Data Exchange (ETDEWEB)

    Kaczmarek, Malgorzata [Department of Rare Earths, Faculty of Chemistry, Adam Mickiewicz University, Grunwaldzka 6, 60 - 780 Poznan (Poland); Lis, Stefan [Department of Rare Earths, Faculty of Chemistry, Adam Mickiewicz University, Grunwaldzka 6, 60 - 780 Poznan (Poland)

    2009-04-20

    A new simple chemiluminescent method for the determination of chlortetracycline (Chlor-TC), oxytetracycline (Oxy-TC) and doxycycline (Doxy-TC) is described. This method is based on the europium(III) emission as a result of the energy transfer process from the excited product of the tetracyclines oxidation to the uncomplexed Eu(III). Under the optimum conditions, calibration graphs were obtained for 4 x 10{sup -7} to 2 x 10{sup -5} mol L{sup -1} of Chlor-TC; 2 x 10{sup -7} to 2 x 10{sup -5} mol L{sup -1} of Oxy-TC and 1 x 10{sup -7} to 3 x 10{sup -5} mol L{sup -1} of Doxy-TC. The method was successfully applied to the determination of these drugs in pharmaceutical and veterinary formulation and honey.

  20. Molecular imprinting-chemiluminescence determination of trimethoprim using trimethoprim-imprinted polymer as recognition material.

    Science.gov (United States)

    He, Yunhua; Lu, Jiuru; Liu, Mei; Du, Jianxiu

    2005-07-01

    A new molecular imprinting-chemiluminescence method for the determination of trimethoprim was developed, in which trimethoprim-imprinted polymer was used as the molecular recognition material and the CL reaction of trimethoprim with potassium permanganate in acidic medium was used as the detection system. The CL intensity responds linearly to the concentration of trimethoprim within the 5.0 x 10(-8)-5.0 x 10(-6) g mL(-1) range (r= 0.9983) with a detection limit of 2 x 10(-8) g mL(-1). The relative standard deviation for the determination of 1.0 x 10(-7) g mL(-1) trimethoprim solutions is 4.8% (n= 9). The method has been applied to the determination of trimethoprim in pharmaceutical preparations and body fluids, and satisfactory results were obtained.

  1. A chemiluminescence reagent free method for the determination of captopril in medicine and urine samples by using trivalent silver

    Directory of Open Access Journals (Sweden)

    Zhaofu Fu

    2017-08-01

    Full Text Available A novel flow-injection chemiluminescence (FI-CL method free of CL reagent was developed for the determination of captopril based on its enhancing effect on the CL derived from diperiodatoargentate(III-sulfuric acid system. Compared with the conventional CL system, the CL system based on trivalent silver was characterized of good selectivity for the absence of CL reagent. The CL mechanism was discussed through CL spectra and UV–vis absorption spectra. The conditions of the FI-CL system were investigated and optimized. Under the optimal conditions, the relative CL intensity was linear with the captopril concentration in the range of 0.3–15.0 μg/mL. The detection limit for captopril was 0.05 μg/mL, and the relative standard deviation (n=11 was 2.0% for 5.0 μg/mL captopril. The proposed method was applied to the analysis of captopril in tablet and human urine with the recoveries of 83.1%–112.5%, and the relative standard deviations of 0.5%–4.4%. The results obtained by the proposed method agreed well with those obtained from HPLC method. The proposed method is fast, convenient, and cost-effective for the determination of captopril in medicine and biological samples.

  2. Highly sensitive chemiluminescent point mutation detection by circular strand-displacement amplification reaction.

    Science.gov (United States)

    Shi, Chao; Ge, Yujie; Gu, Hongxi; Ma, Cuiping

    2011-08-15

    Single nucleotide polymorphism (SNP) genotyping is attracting extensive attentions owing to its direct connections with human diseases including cancers. Here, we have developed a highly sensitive chemiluminescence biosensor based on circular strand-displacement amplification and the separation by magnetic beads reducing the background signal for point mutation detection at room temperature. This method took advantage of both the T4 DNA ligase recognizing single-base mismatch with high selectivity and the strand-displacement reaction of polymerase to perform signal amplification. The detection limit of this method was 1.3 × 10(-16)M, which showed better sensitivity than that of most of those reported detection methods of SNP. Additionally, the magnetic beads as carrier of immobility was not only to reduce the background signal, but also may have potential apply in high through-put screening of SNP detection in human genome. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Electrogenerated chemiluminescence quenching of Ru(bpy){sub 3} {sup 2+} (bpy=2,2 Prime -bipyridine) in the presence of acetaminophen, salicylic acid and their metabolites

    Energy Technology Data Exchange (ETDEWEB)

    Haslag, Catherine S. [Department of Chemistry, Missouri State University, Springfield, Missouri 65897 (United States); Richter, Mark M., E-mail: MarkRichter@missouristate.edu [Department of Chemistry, Missouri State University, Springfield, Missouri 65897 (United States)

    2012-03-15

    Quenching of Ru(bpy) {sub 3}{sup 2+} (bpy=2,2 Prime -bipyridine) coreactant electrogenerated chemiluminescence (ECL) has been observed in the presence of acetaminophen, salicylic acid and related complexes. However, no quenching is observed with the acetylsalicylic acid. In most instances, quenching is observed with 100-fold excess of quencher (compared to ECL luminophore) with complete quenching observed between 10,000 and 100,000 fold excess. Fluorescence and UV-vis experiments coupled with bulk electrolysis support the formation of benzoquinone products upon electrochemical oxidation. The mechanism of quenching may involve the interaction of the electrochemically generated benzoquinone species with (i) the {sup Low-Asterisk }Ru(bpy){sub 3}{sup 2+} excited state or (ii) highly energetic coreactant radicals. - Highlights: Black-Right-Pointing-Triangle Efficient quenching of the electrogenerated chemiluminescence is observed. Black-Right-Pointing-Triangle Acetaminophen, salicylic acid and related compounds can be detected. Black-Right-Pointing-Triangle The mechanism of quenching involves benzoquinones formed upon electrolysis.

  4. Comparison of comprehensive two-dimensional gas chromatography coupled with sulfur-chemiluminescence detector to standard methods for speciation of sulfur-containing compounds in middle distillates.

    Science.gov (United States)

    Ruiz-Guerrero, Rosario; Vendeuvre, Colombe; Thiébaut, Didier; Bertoncini, Fabrice; Espinat, Didier

    2006-10-01

    The monitoring of total sulfur content and speciation of individual sulfur-containing compounds in middle distillates is required for efficient catalyst selection and for a better understanding of the kinetics of the reactions involved in hydrotreament processes. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GCxGC) hyphenated to sulfur chemiluminescence detection (SCD) has recently evolved as a powerful tool for improving characterization and identification of sulfur compounds. The aim of this paper is to compare quantitatively GCxGC-SCD and various other methods commonly employed in the petroleum industry, such as X-ray fluorescence, conventional GC-SCD, and high-resolution mass spectrometry, for total sulfur content determination and speciation analysis. Different samples of middle distillates have been analyzed to demonstrate the high potential and important advantages of GCxGC-SCD for innovative and quantitative analysis of sulfur-containing compounds. More accurate and detailed results for benzothiophenes and dibenzothiophenes are presented, showing that GCxGC-SCD should become, in the future, an essential tool for sulfur speciation analysis.

  5. The effect of supportive E. coli mastitis treatment on PMN chemiluminescence and subpopulations of T lymphocytes.

    Science.gov (United States)

    Markiewicz, H; Krumrych, W; Gehrke, M

    2013-01-01

    The aim of this field study was to assess the impact of a single i.m. injection of lysozyme dimer and flunixin meglumine in combination with intramammary and systemic antibiotic on chemiluminescence of PMN (polymorphonuclear leucocytes) and subpopulations of lymphocyte T in blood of cows with E. coli mastitis. Examinations were performed on 30 dairy cows affected with naturally occurring acute form of E. coli mastitis. Cows were randomly divided into three groups according to the method of treatment. The first group was treated with approved intramammary antibiotic product, the same antibiotic in i.m. injection and one injection of flunixin meglumine on the first day of therapy. Next group was treated with the same antibiotic and additionally one injection of lysozyme dimer on the first day of therapy. The third one was treated only with an antibiotic and served as a control group. Blood samples were taken before treatment and on days 3 and 7. In samples haematology indices were determined, spontaneous and opsonised zymosan stimulated CL and PMA measurements were performed and the subpopulations of T lymphocyte (CD2(+), CD4(+), CD8(+)) were assayed in whole blood. There was no effect of the applied supportive treatment on the value of morphological blood indices. A significant influence of the time of sample collection on the level of CL and dynamics of lymphocytes T subpopulation was demonstrated. A single injection of flunixin meglumine or lysozyme dimer on the day of the beginning of treatment of E. coli mastitis, does not affect the level of neutrophil chemiluminescence and the percentage of T lymphocytes in the blood of mastitic cows in the analysed period of time.

  6. Optimization of condition for conjugation of enrofloxacin to enzymes in chemiluminescence enzyme immunoassay

    Science.gov (United States)

    Yu, Songcheng; Yu, Fei; Zhang, Hongquan; Qu, Lingbo; Wu, Yongjun

    2014-06-01

    In this study, in order to find out a proper method for conjugation of enrofloxacin to label enzymes, two methods were compared and carbodiimide condensation was proved to be better. The results showed that the binding ratio of enrofloxacin and alkaline phosphatase (ALP) was 8:1 and that of enrofloxacin and horseradish peroxidase (HRP) was 5:1. This indicated that conjugate synthesized by carbodiimide condensation was fit for chemiluminescence enzyme immunoassay (CLEIA). Furthermore, data revealed that dialysis time was an important parameter for conjugation and 6 days was best. Buffer to dilute conjugate had little effect on CLEIA. The storage condition for conjugates was also studied and it was shown that the conjugate was stable at 4 °C with no additive up to 30 days. These data were valuable for establishing CLEIA to quantify enrofloxacin.

  7. Flow injection gas chromatography with sulfur chemiluminescence detection for the analysis of total sulfur in complex hydrocarbon matrixes.

    Science.gov (United States)

    Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim

    2018-01-01

    A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  9. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  10. Measurements in international units of antibody to hepatitis B surface antigen(anti-HBs) after immunization with a yeast-derived, subtype adr hepatitis B vaccine are considerably different between chemiluminescent immunoassay (CLIA) and chemiluminescent enzyme immunoassay (CLEIA).

    Science.gov (United States)

    Ogata, Norio

    2006-04-01

    The worldwide consensus of the minimum protective anti-HBs level against HBV infection is 10 mIU/mL on assays standardized by the World Health Organization (WHO) reference preparations. To investigate whether this value could be applied to recipients of yeast-derived recombinant HB vaccine containing the major surface protein of subtype adr (Bimmugen, Astellas Pharmaceutical, Tokyo), we compared anti-HBs measurements between chemiluminescent immunoassay (CLIA) (Architect Ausab, Abbott Japan, Tokyo) and chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse Forte, Fujirebio, Tokyo) in given serum samples obtained from the vaccinees. The vaccine and the two assay methods are currently in a wide use in Japan. The study included 300 medical students who completed a standard vaccination course (0, 1 and 6 months). Serum samples obtained 1 month or 13 months after completing the vaccination were simultaneously tested for anti-HBs by CLIA and CLEIA. In 147 samples with quantifiable values on both CLIA and CLEIA (10 to 1000 mIU/mL) the geometric mean titer on CLEIA (225.0 mIU/mL) was significantly higher than that on CLIA (94.5 mIU/mL) (p < 0.0001). Of 26 subjects with CLIA measurements below 10 mIU/mL, 15 samples (57.7%) showed CLEIA measurements more than 10 mIU/mL. Thus, in the subtype adr-vaccinees CLEIA demonstrated considerably high serum anti-HBs measurements compared to CLIA and discordance in determining critical anti-HBs level of 10 mIU/mL was observed in more than half the samples. This suggests that the minimum HBV-protective anti HBs titer of 10 mIU/mL is difficult to be introduced to Japan where subtype adr-HB vaccines or -HBV infection are prevalent, unless characteristics of assay methods are carefully evaluated.

  11. Electro chemiluminescence Biosensor Based on Thioglycolic Acid-Capped Cd Se QDs for Sensing Glucose

    International Nuclear Information System (INIS)

    Jung, E. Y.; Ye, J. H.; Choi, S. H.; Jung, S. H.

    2016-01-01

    In order to detect low level glucose concentration, an electro chemiluminescence (ECL) biosensor based on TGA-capped Cd Se quantum dots (QDs) was fabricated by the immobilization of Cd Se QDs after modifying the surface of a glassy carbon electrode (GCE) with 4-amino thiophenol diazonium salts by the electrochemical method. For the detection of glucose concentration, glucose oxidase (GOD) was immobilized onto the fabricated Cd Se QDs-modified electrode. The fabricated ECL biosensor based on TGA-capped Cd Se QDs was characterized using a scanning electron microscope (SEM), UV-vis spectrophotometry, transmission electron microscopy (TEM), a fluorescence spectrometer (PL), and cyclic voltammetry (CV). The fabricated ECL biosensor based on TGA-capped Cd Se QDs is suitable for the detection of glucose concentrations in real human blood samples.

  12. Sensitized chemiluminescence of 2-phenyl-4,5-di(2-furyl)-1H-imidazole/K₃Fe(CN)₆/propyl gallate system combining with solid-phase extraction for the determination of propyl gallate in edible oil.

    Science.gov (United States)

    Kang, Jing; Han, Lu; Chen, Zhonglin; Shen, Jimin; Nan, Jun; Zhang, Yihua

    2014-09-15

    In this paper, a novel chemiluminescence (CL) method has been developed for the determination of propyl gallate (PG). The proposed method was based on the enhancing effect of PG on the CL signal of 2-phenyl-4,5-di(2-furyl)-1H-imidazole (PDFI) and K3Fe(CN)6 reaction in an alkaline solution. Under the optimum conditions, the enhanced CL intensity was linearly related to the concentration of PG. The linear range of the calibration curve was 0.05-8 μg/mL, and the corresponding detection limit (3σ) was 0.036 μg/mL. The relative standard deviation for determining 1.0 μg/mL PG was 2.8% (n=11). The proposed method has been successfully applied to the determination of PG in edible oil. The edible oil samples were prepared by the solid-phase extraction (SPE) with a C18 column served as the stationary phase. Furthermore, the possible CL mechanism was also discussed briefly based on the photoluminescence (PL) and CL spectra. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Expression of IL-17A concentration and effector functions of peripheral blood neutrophils in food allergy hypersensitivity patients.

    Science.gov (United States)

    Żbikowska-Gotz, Magdalena; Pałgan, Krzysztof; Gawrońska-Ukleja, Ewa; Kuźmiński, Andrzej; Przybyszewski, Michał; Socha, Ewa; Bartuzi, Zbigniew

    2016-03-01

    Lymphocytes Th17 and other types of immune system cells produce IL17. By induction of cytokines and chemokines, the IL17 cytokine is involved in mechanisms of allergic reaction with participation of neutrophil granulocytes. It affects activation, recruitment, and migration of neutrophils to the tissues, regulating inflammatory reaction intensity. Excited neutrophils secrete inter alia elastase and reactive oxygen species (ROS)--significant mediators of inflammation process responsible for tissues damage.The aim of the study was to evaluate the concentrations of serum interleukin 17A, serum neutrophil elastase, and ROS production by neutrophils in patients with food allergy.The study included 30 patients with food allergy diagnosed based on interview, clinical symptoms, positive SPT, placebo controlled double-blind oral provocation trial, and the presence of asIgE in blood serum against selected food allergens using fluoro-immuno-enzymatic method FEIA UNICap 100. The control group consisted of 10 healthy volunteers. The concentrations of IL17A were determined in all patients using ELISA method with eBioscience kits, and elastase using BenderMed Systems kits. Chemiluminescence of non-stimulated neutrophils was evaluated using luminol-dependent kinetic method for 40 min on Luminoskan (Labsystems luminometer).The results of serum IL-17A concentrations and the values of chemiluminescence obtained by non-activated neutrophils, as well as elastase concentrations, were higher in patients with food allergic hypersensitivity compared to healthy volunteers.This study demonstrates a significance of IL-17A and activated neutrophil granulocytes in the course of diseases with food allergic hypersensitivity. © The Author(s) 2015.

  14. Interferences of commercial NO2 instruments in the urban atmosphere and in a smog chamber

    Directory of Open Access Journals (Sweden)

    J. Kleffmann

    2012-01-01

    Full Text Available Reliable measurements of atmospheric trace gases are necessary for both, a better understanding of the chemical processes occurring in the atmosphere, and for the validation of model predictions. Nitrogen dioxide (NO2 is a toxic gas and is thus a regulated air pollutant. Besides, it is of major importance for the oxidation capacity of the atmosphere and plays a pivotal role in the formation of ozone and acid precipitation. Detection of NO2 is a difficult task since many of the different commercial techniques used are affected by interferences. The chemiluminescence instruments that are used for indirect NO2 detection in monitoring networks and smog chambers use either molybdenum or photolytic converters and are affected by either positive (NOy or negative interferences (radical formation in the photolytic converter. Erroneous conclusions on NO2 can be drawn if these interferences are not taken into consideration. In the present study, NO2 measurements in the urban atmosphere, in a road traffic tunnel and in a smog-chamber using different commercial techniques, i.e. chemiluminescence instruments with molybdenum or photolytic converters, a Luminol based instrument and a new NO2-LOPAP, were compared with spectroscopic techniques, i.e. DOAS and FTIR. Interferences of the different instruments observed during atmospheric measurements were partly characterised in more detail in the smog chamber experiments. Whereas all the commercial instruments showed strong interferences, excellent agreement was obtained between a new NO2-LOPAP instrument and the FTIR technique for the measurements performed in the smog chamber.

  15. Application of a Newly Developed High-Sensitivity HBsAg Chemiluminescent Enzyme Immunoassay for Hepatitis B Patients with HBsAg Seroclearance

    OpenAIRE

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-01-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstr...

  16. Usage of liquid scintillation counting for detecting the chemiluminescence of cells and its application in medicine

    International Nuclear Information System (INIS)

    Li Tianxing; Liang Qizhong; Zou Xiaowei; Yang Zhaohen; Huang Yong; Li Huaqiang

    1995-01-01

    The liquid scintillator counting-chemiluminescence (LSC-CL) of mono-photon radiance is a sensitive, handy and high-autoanalytic technique. Through measuring basic CL, dependent CL and maximum phagocytic CL of polymorphonuclear (PMN), we studied best factor levels of the method with orthogonal design [L 9 (3 4 )]. The results showed the peak forms changed markedly (inter-group P -4 M). PMN-CL in blood was measured during acute attack of the old patients with chronic bronchitis and the children with pneumonia bronchial. It was suggested that PMN phagocytosis decreased. So the dynamic analysis of maximum phagocytic CL would help us with the deep going clinical researches of the mechanisms of anti-inflammation and injuring by the oxygen free radicals

  17. Hypericin from St. John’s Wort (hypericum perforatum) as a novel natural fluorophore for chemiluminescence reaction of bis (2,4,6-trichlorophenyl) oxalate–H2O2–imidazole and quenching effect of some natural lipophilic hydrogen peroxide scavengers

    International Nuclear Information System (INIS)

    Kazemi, Sayed Yahya; Abedirad, Seyed Mohammad; Zali, Seyed Hassan; Amiri, Mohadeseh

    2012-01-01

    Hypericin (HYP) molecule is a natural photoactive pigment, which plays a role as an effective photoreceptor in some plants of the Hypericum species (the most common of which is Saint John’s Wort) and some insect species. The present work deals with the first attempt to the study of peroxyoxalate chemiluminescence (POCL) system in the presense of HYP as a natural fluorophore. Reaction of bis (2,4,6-trichlorophenyl) oxalate(TCPO)–H 2 O 2 –imidazole can transfer energy to a HYP via formation of dioxetane through the chemically initiated electron exchange luminescence (CIEEL) mechanism and can emits a very intense red light. The effects of HYP, hydrogen peroxide, TCPO and imidazole concentrations on kinetic chemiluminescence parameters were also studied. These parameters including rise and fall rate constant for the chemiluminescence burst, theoretical and experimental maximum intensity, theoretical and experimental time to reach maximum intensity and total light yield emission were evaluated by using a pooled intermediate model for a non-linear least-squares curve fitting program, KINFIT. Moreover, quenching effect of two lipophilic natural antioxidant, Quercetin and β-carotene on it system was also investigated. The measurable concentration range of 7×10 −6 M to 7.5×10 −5 M of antioxidants were evaluated from the proper Stern–Volmer plots with satisfactory RSD% and corresponding detection limits of 2.2×10 −6 and 3.7×10 −6 for β-carotene and quercetin respectively. - Highlights: ► Red fluorophores may therefore chemiluminescence more intensely than other commonly chemiluminophores and emits light in longer wavelengths. ► Hypericin from St. John’s wort (hypericum perforatum) as natural red fluorophore for peroxyoxalate chemiluminescence was introduced. ► Quenching effect of two antioxidant, quercetin and β-carotene on it system was also investigated. ► The non linear least-squares curve fitting program KINFIT was applied to study of CL

  18. Directly oxidized chemiluminescence of 2-substituted-4,5-di(2-furyl)-1H -imidazole by acidic potassium permanganate and its analytical application for determination of albumin.

    Science.gov (United States)

    Kang, Jing; Zhang, Yumin; Huang, Zhongxiu; Han, Lu; Tang, Jieli; Wang, Shuaijun; Zhang, Yihua

    2011-07-01

    In the paper, 2,4,5-tri(2-furyl)-1H-imidazole (TFI) and 2-phenyl-4,5-di(2-furyl)-1H-imidazole (PDFI), were chosen to investigate chemiluminescence (CL) properties of 2-substituted-4,5-di(2-furyl)-1H-imidazoles. The directly oxidized CL of analytes by potassium permanganate (KMnO(4)) was in detail studied. The KMnO(4) could directly oxidize TFI/PDFI to produce strong CL emission in acidic solution. The effects of experimental conditions were investigated. Under the optimal conditions, the effect of albumin on the TFI/PDFI-KMnO(4) system was investigated. It was found that the addition of albumin into the system could induce enhancement of CL signal, and the enhanced CL intensity is linearly related to the logarithm of concentration of albumin. Based on this study, a novel CL method has been developed for the determination of albumin with high sensitivity and good selectivity. The method was applied to the determination of albumin in human serum samples, and the results were in agreement with those obtained by the bromcresol green (BCG) method. The relative errors for the analytical results were from -5.8% to 4.2%. These new phenomena would further enable people to exploit more CL analytical application of the heterocyclic imidazole derivatives. © Springer Science+Business Media, LLC 2011

  19. The investigation of photo-induced chemiluminescence on Co2+-doped TiO2 nanoparticles and its analytical application.

    Science.gov (United States)

    Li, Guixin; Nan, Hongyan; Zheng, Xingwang

    2009-07-01

    A novel space- and time-resolved photo-induced chemiluminescence (PICL) analytical method was developed based on the photocatalysis of the Co2+-doped TiO2 nanoparticles. The PICL reaction procedure under the photocatalysis of Co2+-doped TiO2 nanoparticles was investigated using cyclic voltammetry and potentiometry. Meanwhile, the effect of the electrical double layer outside the Co2+-doped TiO2 nanoparticles on the PICL was investigated by contrasting with the Co2+-doped TiO2-SiO2 core-shell nanoparticles. Significantly, the CL intensity increased apparently and the time of the CL was prolonged in the presence of procaterol hydrochloride because the mechanism of the enhanced PICL reaction may be modified. The route of the PICL was changed due to the participation of the procaterol hydrochloride enriched at the surface of the Co2+-doped TiO2-SiO2 in the PICL reaction, which prolonged the time of the CL reaction and resulted in the long-term PICL. The analytical characteristics of the proposed in-situ PICL method were investigated using the procaterol hydrochloride as the model analyte. The investigation results showed that this new PICL analytical method offered higher sensitivity to the analysis of the procaterol hydrochloride and the PICL intensity was linear with the concentration of the procaterol hydrochloride in the range from ca. 2.0 x 10(-10) to 1.0 x 10(-8) g mL(-1).

  20. DNA origami nanorobot fiber optic genosensor to TMV.

    Science.gov (United States)

    Torelli, Emanuela; Manzano, Marisa; Srivastava, Sachin K; Marks, Robert S

    2018-01-15

    In the quest of greater sensitivity and specificity of diagnostic systems, one continually searches for alternative DNA hybridization methods, enabling greater versatility and where possible field-enabled detection of target analytes. We present, herein, a hybrid molecular self-assembled scaffolded DNA origami entity, intimately immobilized via capture probes linked to aminopropyltriethoxysilane, onto a glass optical fiber end-face transducer, thus producing a novel biosensor. Immobilized DNA nanorobots with a switchable flap can then be actuated by a specific target DNA present in a sample, by exposing a hemin/G-quadruplex DNAzyme, which then catalyzes the generation of chemiluminescence, once the specific fiber probes are immersed in a luminol-based solution. Integrating organic nanorobots to inorganic fiber optics creates a hybrid system that we demonstrate as a proof-of-principle can be utilized in specific DNA sequence detection. This system has potential applications in a wide range of fields, including point-of-care diagnostics or cellular in vivo biosensing when using ultrathin fiber optic probes for research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. [The criterion prognostic significance of examinations of chemiluminescence of oral fluid under impact of chemical pollutants of manufacture of rubber and rubber technical production].

    Science.gov (United States)

    Galiullina, E F; Valiev, A v; Kamilov, R F; Shakirov, D F; Buliakov, P T

    2013-12-01

    The article presents the results of studies concerning the effect of unfavorable factors of chemical nature on fluid of oral cavity among workers of the Ufa plant of elastomer materials, articles and structures. It is established that in persons contacting with chemical pollutants of manufacture of rubber and rubber technical production the indicators of chemiluminescence of saliva fluid are significantly expressed and depend on professional standing.

  2. Novel assay of antibacterial components in manuka honey using lucigenin-chemiluminescence-HPLC

    International Nuclear Information System (INIS)

    Karasawa, Koji; Haraya, Shiomi; Okubo, Sachie; Arakawa, Hidetoshi

    2017-01-01

    Five components (hydrogen peroxide, methylglyoxal, dihydroxyacetone, fructose and glucose) of New Zealand manuka honey (Leptospermum scoparium) were analyzed using lucigenin chemiluminescence high-performance liquid chromatography (lucigenin-CL-HPLC). We focused on active oxygen species produced from the components in order to easily detect these five components contained in manuka honey. H_2O_2 and O_2"− generated from these components were identified by lucigenin-CL and electron spin resonance (ESR), and the bactericidal effect of ROS was confirmed using E. coli. The previously reported assays for Manuka honey components have low specificities and require complicated preprocessing methods. As our results, the detection and identification of these components were possible within 30 min in lucigenin-CL-HPLC system, without any special treatment. It is considered that lucigenin-CL-HPLC is useful for the quality control and the analysis of various honey. - Highlights: • Antibacterial components in manuka honey by HPLC with lucigenin-CL. • Five antibacterial compounds measured via generation of reactive oxygen species. • Simple, sensitive and useful for quality control and analysis of antibacterial honey.

  3. Electrochemistry and electrogenerated chemiluminescence of films of silicon nanoparticles in aqueous solution

    International Nuclear Information System (INIS)

    Bae, Yoonjung; Lee, Doh C; Rhogojina, Elena V; Jurbergs, David C; Korgel, Brian A; Bard, Allen J

    2006-01-01

    Films of octadecyl-capped Si nanoparticles (NPs) (diameter, 3.4 ± 0.7 nm) prepared by drop-coating on indium tin oxide (ITO) showed electrogenerated chemiluminescence (ECL) for both cathodic and anodic potential sweeps in KOH solutions containing peroxydisulfate. The redox potentials of the Si NPs can be estimated as approximately -0.9 and +0.95 V (versus Ag|AgCl) based on the anodic potential for the onset of ECL minus the ECL peak energy. The ECL exhibits a relatively broad spectrum (FWHM = 160 nm) with a peak wavelength of ∼670 nm (1.85 eV), similar to the photoluminescence spectra. In electrochemical studies in KOH solution in the absence of peroxydisulfate, an anodic current peak appears at about -1 V (versus Ag|AgCl) following a scan to negative potentials. A similar peak has been observed during the etching of a bulk single crystal Si electrode in alkaline aqueous solution. Unpassivated surface sites of Si NPs seem to be etched at potentials negative of the anodic oxidation peak

  4. Prospective validation of an automated chemiluminescence-based assay of renin and aldosterone for the work-up of arterial hypertension.

    Science.gov (United States)

    Rossi, Gian Paolo; Ceolotto, Giulio; Rossitto, Giacomo; Seccia, Teresa Maria; Maiolino, Giuseppe; Berton, Chiara; Basso, Daniela; Plebani, Mario

    2016-09-01

    The availability of simple and accurate assays of plasma active renin (DRC) and aldosterone concentration (PAC) can improve the detection of secondary forms of arterial hypertension. Thus, we investigated the performance of an automated chemiluminescent assay for DRC and PAC in referred hypertensive patients. We prospectively recruited 260 consecutive hypertensive patients referred to an ESH Center for Hypertension. After exclusion of six protocol violations, 254 patients were analyzed: 67.3% had primary hypertension, 17.3% an aldosterone producing adenoma (APA), 11.4% idiopathic hyperaldosteronism (IHA), 2.4% renovascular hypertension (RVH), 0.8% familial hyperaldosteronism type 1 (FH-1), 0.4% apparent mineralocorticoid excess (AME), 0.4% a renin-producing tumor, and 3.9% were adrenalectomized APA patients. Bland-Altman plots and Deming regression were used to analyze results. The diagnostic accuracy (area under the curve, AUC of the ROC) of the DRC-based aldosterone-renin ratio (ARRCL) was compared with that of the PRA-based ARR (ARRRIA) using as reference the conclusive diagnosis of APA. At Bland-Altman plot, the DRC and PAC assay showed no bias as compared to the PRA and PAC assay. A tight relation was found between the DRC and the PRA values (concordance correlation coefficient=0.92, pAPA identification the AUC of the ARRCL was higher than that of the ARRRIA [0.974 (95% CI 0.940-0.991) vs. 0.894 (95% CI 0.841-0.933), p=0.02]. This rapid automated chemiluminescent DRC/PAC assay performed better than validated PRA/PAC radioimmunoassays for the identification of APA in referred hypertensive patients.

  5. New electrochemiluminescence catalyst: Cu2O semiconductor crystal and the enhanced activity of octahedra synthesized by iodide ions coordination

    DEFF Research Database (Denmark)

    Zhang, Ling; Qi, Liming; Gao, Wenyue

    2017-01-01

    Cuprous oxide (Cu2O) crystals are usually used as the photocatalysts of water splittings and carbon monoxide oxidations. Herein, we report the new catalytic properties of Cu2O to the electrochemilumenescence (ECL) reactions of luminol and oxygen. Adjusting the shape of Cu2O microcrystals from cub...

  6. Development of a method for the characterization of the oxidation stability of domestic heating oil and domestic heating oil with alternative components using chemiluminescence; Entwicklung einer Analysemethode zur Charakterisierung der Oxidationsstabilitaet von Heizoel EL und Heizoel EL A mittels Chemilumineszenz

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Winfried; Lukito, Jayadi; Schloss, Heide vom [Oel-Waerme-Institut gGmbH (OWI), Aachen-Herzogenrath (Germany)

    2013-04-15

    The project's aim was to develop a process that serves to determine the oxidation stability of heating oil - FAME-/ heating oil - vegetable oil-blends clearly. Due to a directed energy input by means of the process of chemiluminescence, statements about the storage stability and the thermal stability of blends can be made. During the process the ageing of blend components and of the heating oil are taken into consideration. As a result, ageing processes and products of pure heating oil as well as biogenic components can be determined. It was shown that the process is applicable to blends up to an admixture of at least 20 % (V/V) of biogenic components, whereby blends with higher admixture shares can be analyzed as well. According to DIN SPEC 51603 - 6 'Heating Oil Alternative' the admixture of FAME is limited to 20 %(V/V) and the admixture of vegetable oil to 5 % (V/V) because of the distillation range. On the basis of these investigations it could be shown how oxidation products influence the signal process of the chemiluminescence radiation and how they can be correlated by a measurable physical value. Moreover, a new evaluation criterion has been developed. By means of this criterion a good reproducibility - regarding the determination of the oxidation stability according to the chemiluminescence methodology for non-aged fuels - can be achieved. The fuel characteristic decrease in the stability of the tested fuels can be represented only partially by the chemiluminescence process, as the measured values are subject to fluctuations. (orig.)

  7. Effect of therapeutic plasma concentrations of non-steroidal anti-inflammatory drugs on the production of reactive oxygen species by activated rat neutrophils

    Directory of Open Access Journals (Sweden)

    Paino I.M.M.

    2005-01-01

    Full Text Available The release of reactive oxygen specie (ROS by activated neutrophil is involved in both the antimicrobial and deleterious effects in chronic inflammation. The objective of the present investigation was to determine the effect of therapeutic plasma concentrations of non-steroidal anti-inflammatory drugs (NSAIDs on the production of ROS by stimulated rat neutrophils. Diclofenac (3.6 µM, indomethacin (12 µM, naproxen (160 µM, piroxicam (13 µM, and tenoxicam (30 µM were incubated at 37ºC in PBS (10 mM, pH 7.4, for 30 min with rat neutrophils (1 x 10(6 cells/ml stimulated by phorbol-12-myristate-13-acetate (100 nM. The ROS production was measured by luminol and lucigenin-dependent chemiluminescence. Except for naproxen, NSAIDs reduced ROS production: 58 ± 2% diclofenac, 90 ± 2% indomethacin, 33 ± 3% piroxicam, and 45 ± 6% tenoxicam (N = 6. For the lucigenin assay, naproxen, piroxicam and tenoxicam were ineffective. For indomethacin the inhibition was 52 ± 5% and diclofenac showed amplification in the light emission of 181 ± 60% (N = 6. Using the myeloperoxidase (MPO/H2O2/luminol system, the effects of NSAIDs on MPO activity were also screened. We found that NSAIDs inhibited both the peroxidation and chlorinating activity of MPO as follows: diclofenac (36 ± 10, 45 ± 3%, indomethacin (97 ± 2, 100 ± 1%, naproxen (56 ± 8, 76 ± 3%, piroxicam (77 ± 5, 99 ± 1%, and tenoxicam (90 ± 2, 100 ± 1%, respectively (N = 3. These results show that therapeutic levels of NSAIDs are able to suppress the oxygen-dependent antimicrobial or oxidative functions of neutrophils by inhibiting the generation of hypochlorous acid.

  8. Real time imaging of live cell ATP leaking or release events by chemiluminescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yun [Iowa State Univ., Ames, IA (United States)

    2008-12-18

    The purpose of this research was to expand the chemiluminescence microscopy applications in live bacterial/mammalian cell imaging and to improve the detection sensitivity for ATP leaking or release events. We first demonstrated that chemiluminescence (CL) imaging can be used to interrogate single bacterial cells. While using a luminometer allows detecting ATP from cell lysate extracted from at least 10 bacterial cells, all previous cell CL detection never reached this sensitivity of single bacteria level. We approached this goal with a different strategy from before: instead of breaking bacterial cell membrane and trying to capture the transiently diluted ATP with the firefly luciferase CL assay, we introduced the firefly luciferase enzyme into bacteria using the modern genetic techniques and placed the CL reaction substrate D-luciferin outside the cells. By damaging the cell membrane with various antibacterial drugs including antibiotics such as Penicillins and bacteriophages, the D-luciferin molecules diffused inside the cell and initiated the reaction that produces CL light. As firefly luciferases are large protein molecules which are retained within the cells before the total rupture and intracellular ATP concentration is high at the millmolar level, the CL reaction of firefly luciferase, ATP and D-luciferin can be kept for a relatively long time within the cells acting as a reaction container to generate enough photons for detection by the extremely sensitive intensified charge coupled device (ICCD) camera. The result was inspiring as various single bacterium lysis and leakage events were monitored with 10-s temporal resolution movies. We also found a new way of enhancing diffusion D-luciferin into cells by dehydrating the bacteria. Then we started with this novel single bacterial CL imaging technique, and applied it for quantifying gene expression levels from individual bacterial cells. Previous published result in single cell gene expression quantification

  9. Development of a reagentless electrochemiluminescent electrode for flow injection analysis using copolymerised luminol/aniline on nano-TiO2 functionalised indium-tin oxide glass.

    Science.gov (United States)

    Liu, Chao; Wei, Xiuhua; Tu, Yifeng

    2013-07-15

    In this study, a nano-structured copolymer of luminol/aniline (PLA) was deposited onto nano-TiO2-functionalised indium tin oxide (ITO)-coated glass by electrochemical polymerisation using cyclic voltammetry (CV). The resulting reagentless electrochemiluminescent (ECL) electrode (ECLode) can be used for flow injection analysis (FIA). The properties of the ECLode were characterised by CV, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The ECLode has high background ECL emission as well as excellent stability and reproducibility, and yielding sensitive response towards target analytes. The ECL emissions of the ECLode were 50 times higher than PLA/ITO, and 500 times higher than polyluminol (PL)/ITO. The ECLode showed sensitive responses to reactive oxygen species (ROSs), permitting its application for determination of antioxidants by quenching. Under optimised conditions, an absolute detection limit of 69.9 pg was obtained for resveratrol, comparable to the highest levels of sensitivity achieved by other methods. Thus, the gross antioxidant content of red wine was determined, with satisfactory recoveries between 87.6% and 108.3%. These results suggest a bright future for the use of the ECLode for single-channel FIA due to its high sensitivity, accuracy and reproducibility. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Chemiluminescence measurement of cinnamon-, curry-, red pepper- and milk powder as a method to identify ionizing radiation treatment. Die Messung der Chemilumineszenz von Zimt-, Curry-, Paprika- und Milchpulver als Nachweis einer Behandlung mit ionisierenden Strahlen

    Energy Technology Data Exchange (ETDEWEB)

    Boegl, W; Heide, L

    1983-11-01

    The findings may be summarized as follows: significant differences in the dose response relationship of the different foodstuffs were found; the chemiluminescence intensity of different foodstuffs irradiated at equal dose levels may vary considerably; in some cases there might be evidence of radiation treatment even 2 months afterwards; after heating, the irradiated foodstuffs showed reduced chemiluminescence intensity. In some cases it is, however, possible to identify previous irradiation of a foodstuff; if irradiated foodstuffs are treated with water vapor, the radicals will react with the water so as to preclude the identification of previous irradiation; UV-irradiation will result in a drastic increase in luminescence intensity, at least in some cases and air oxidation may also increase the luminescence intensity, especially in fatty foodstuffs.

  11. Extra-weak chemiluminescence produced by autoxidation of kampo extract preparations stored in heat-stressed conditions.

    Science.gov (United States)

    Sato, H; Hirayama, H; Yamamoto, T; Ishizawa, F; Mizugaki, M

    1998-06-01

    The purpose of this study was to evaluate the usefulness of extra-weak chemiluminescence (CL) measurement as a rapid method to estimate the stability of Kampo extract preparations. It was found that the Kampo drugs that emit little CL were stable, while those with higher CL were comparatively unstable with regard to the various stability markers, including change of coloration (browning), contents of specific ingredients, high molecular compounds, amino acids and sugars under various conditions of heat storage. Excellent correlation existed between the CL of Kampo drugs and the coloration (delta E* (ab)) and the other above-mentioned evaluation markers. From this investigation, it was deduced that the CL of Kampo drugs originates in the early stage of the Maillard reaction and reflects the stability of the preparations, and that CL is useful for estimating the stability of Kampo drugs.

  12. Decoupling peroxyacetyl nitrate from ozone in Chinese outflows observed at Gosan Climate Observatory

    Science.gov (United States)

    Han, Jihyun; Lee, Meehye; Shang, Xiaona; Lee, Gangwoong; Emmons, Louisa K.

    2017-09-01

    We measured peroxyacetyl nitrate (PAN) and other reactive species such as O3, NO2, CO, and SO2 with aerosols including mass, organic carbon (OC), and elemental carbon (EC) in PM2. 5 and K+ in PM1. 0 at Gosan Climate Observatory in Korea (33.17° N, 126.10° E) during 19 October-6 November 2010. PAN was determined through fast gas chromatography with luminol chemiluminescence detection at 425 nm every 2 min. The PAN mixing ratios ranged from 0.1 (detection limit) to 2.4 ppbv with a mean of 0.6 ppbv. For all measurements, PAN was unusually better correlated with PM2. 5 (Pearson correlation coefficient, γ = 0.79) than with O3 (γ = 0.67). In particular, the O3 level was highly elevated with SO2 at midnight, along with a typical midday peak when air was transported rapidly from the Beijing areas. The PAN enhancement was most noticeable during the occurrence of haze under stagnant conditions. In Chinese outflows slowly transported over the Yellow Sea, PAN gradually increased up to 2.4 ppbv at night, in excellent correlation with a concentration increase in PM2. 5 OC and EC, PM2. 5 mass, and PM1. 0 K+. The high K+ concentration and OC / EC ratio indicated that the air mass was impacted by biomass combustion. This study highlights PAN decoupling with O3 in Chinese outflows and suggests PAN as a useful indicator for diagnosing continental outflows and assessing their perturbation of regional air quality in northeast Asia.

  13. Novel and versatile solid-state chemiluminescence sensor based on TiO2-Ru(bpy)32+ nanoparticles for pharmaceutical drugs detection

    Science.gov (United States)

    Al-Hetlani, Entesar; Amin, Mohamed O.; Madkour, Metwally

    2018-02-01

    This work describes a novel and versatile solid-state chemiluminescence sensor for analyte detection using TiO2-Ru(bpy)32+-Ce(IV). Herein, we report the synthesis, characterization, optimization and application of a new type of hybrid nanoparticles (NPs). Mesoporous TiO2-Ru(bpy)32+ NPs were prepared using a modified sol-gel method by incorporating Ru(bpy)32+ into the initial reaction mixture at various concentrations. The resultant bright orange precipitate was characterized via transmission electron microscopy, N2 sorpometry, inductively coupled plasma-optical emission spectrometer (ICP-OES), Raman and UV-Vis spectroscopy techniques. The concentration of Ru(bpy)32+ complex in the NPs was quantified using ICP-OES, and its chemiluminescence (CL) response was measured and compared with the same concentration in the liquid phase using oxalate as model analyte. The results showed that this type of hybrid material exhibited a higher CL signal compared with the liquid phase due to the enlarged surface area of the hybrid NPs ( 149.6 m2/g). The amount of TiO2-Ru(bpy)32+ NPs and the effect of the analyte flow rate were also investigated to optimize the CL signal. The optimized system was further used to detect oxalate and two pharmaceutical drugs, namely, imipramine and promazine. The linear range for both drugs was 1-100 pm with limits of detection (LOD) of 0.1 and 0.5 pm, respectively. This approach is considered to be simple, low cost and facile and can be applied to a wide range of analytes.

  14. Novel and versatile solid-state chemiluminescence sensor based on TiO2-Ru(bpy32+ nanoparticles for pharmaceutical drugs detection

    Directory of Open Access Journals (Sweden)

    Al-Hetlani Entesar

    2018-02-01

    Full Text Available This work describes a novel and versatile solid-state chemiluminescence sensor for analyte detection using TiO2-Ru(bpy32+-Ce(IV. Herein, we report the synthesis, characterization, optimization and application of a new type of hybrid nanoparticles (NPs. Mesoporous TiO2-Ru(bpy32+ NPs were prepared using a modified sol-gel method by incorporating Ru(bpy32+ into the initial reaction mixture at various concentrations. The resultant bright orange precipitate was characterized via transmission electron microscopy, N2 sorpometry, inductively coupled plasma-optical emission spectrometer (ICP-OES, Raman and UV-Vis spectroscopy techniques. The concentration of Ru(bpy32+ complex in the NPs was quantified using ICP-OES, and its chemiluminescence (CL response was measured and compared with the same concentration in the liquid phase using oxalate as model analyte. The results showed that this type of hybrid material exhibited a higher CL signal compared with the liquid phase due to the enlarged surface area of the hybrid NPs (~149.6 m2/g. The amount of TiO2-Ru(bpy32+ NPs and the effect of the analyte flow rate were also investigated to optimize the CL signal. The optimized system was further used to detect oxalate and two pharmaceutical drugs, namely, imipramine and promazine. The linear range for both drugs was 1–100 pm with limits of detection (LOD of 0.1 and 0.5 pm, respectively. This approach is considered to be simple, low cost and facile and can be applied to a wide range of analytes.

  15. Potassium permanganate-glutaraldehyde chemiluminescence system catalyzed by gold nanoprisms toward selective determination of fluoride.

    Science.gov (United States)

    Abolhasani, Jafar; Hassanzadeh, Javad; Ghorbani-Kalhor, Ebrahim

    2016-02-01

    Gold and silver nanoparticles (NPs) are shown to exert a positive effect on the chemiluminescence (CL) reaction of permanganate aldehydes. Interestingly, between various shapes examined, Au nanoprisms have the highest beneficial effect. This effect is even more notable in the presence of sodium dodecyl sulfate (SDS) surfactant. UV-vis spectra and transmission electron microscopy were used to characterize the NP shapes and sizes. Furthermore, it was observed that iron(III) ions can slightly increase CL emission of this system. This intensification is very effective in the presence of fluoride ions (F(-)). These observations form the basis of the method for the high sensitive determination of F(-) in the 6-1200 nmol L(-1) concentration range, with a detection limit of 2.1 nmol L(-1). The proposed method has good precision and was satisfactorily used in the selective determination of low concentrations of fluoride ion in real samples. Copyright © 2015 John Wiley & Sons, Ltd.

  16. New method for monitoring nitric oxide in vivo using microdialysis sampling and chemiluminescence reaction

    Science.gov (United States)

    Yao, Dachun; Evmiridis, Nick P.; Zhou, Yikai; Xu, Shunqing; Zhou, Huarong

    2001-09-01

    A new method employing a combination of micro dialysis sampling and chemiluminescence reaction was developed to monitor nitric oxide (NO) in vivo. A special probe was designed with an interference-free membrane to achieve a very high selectivity for NO. High sensitivity was achieved by optimizing the working system and improving the NO sampling time. This system was used in vivo to monitor blood and brain tissue in rats and rabbits. We have established that this system is sensitive enough to detect variations in NO production in difference physiological state. The system can detect NO in the linear range of 5nM-1(mu) M, with a detection limit of 1nM, and real NO concentrations in our experimental animals were found to be in the range of 1-5 nM or even less. Finally, the effects of body temperature, NO donors, Viagra, NO activators, NO cofactors, NO interference were investigated carefully in different physiological situations.

  17. Internal Light Source-Driven Photoelectrochemical 3D-rGO/Cellulose Device Based on Cascade DNA Amplification Strategy Integrating Target Analog Chain and DNA Mimic Enzyme.

    Science.gov (United States)

    Lan, Feifei; Liang, Linlin; Zhang, Yan; Li, Li; Ren, Na; Yan, Mei; Ge, Shenguang; Yu, Jinghua

    2017-11-01

    In this work, a chemiluminescence-driven collapsible greeting card-like photoelectrochemical lab-on-paper device (GPECD) with hollow channel was demonstrated, in which target-triggering cascade DNA amplification strategy was ingeniously introduced. The GPECD had the functions of reagents storage and signal collection, and the change of configuration could control fluidic path, reaction time and alterations in electrical connectivity. In addition, three-dimentional reduced graphene oxide affixed Au flower was in situ grown on paper cellulose fiber for achieving excellent conductivity and biocompatibility. The cascade DNA amplification strategy referred to the cyclic formation of target analog chain and its trigger action to hybridization chain reaction (HCR), leading to the formation of numerous hemin/G-quadruplex DNA mimic enzyme with the presence of hemin. Subjected to the catalysis of hemin/G-quadruplex, the strong chemiluminiscence of luminol-H 2 O 2 system was obtained, which then was used as internal light source to excite photoactive materials realizing the simplification of instrument. In this analyzing process, thrombin served as proof-of-concept, and the concentration of target was converted into the DNA signal output by the specific recognition of aptamer-protein and target analog chain recycling. The target analog chain was produced in quantity with the presence of target, which further triggered abundant HCR and introduced hemin/G-quadruplex into the system. The photocurrent signal was obtained after the nitrogen-doped carbon dots sensitized ZnO was stimulated by chemiluminescence. The proposed GPECD exhibited excellent specificity and sensitivity toward thrombin with a detection limit of 16.7 fM. This judiciously engineered GPECD paved a luciferous way for detecting other protein with trace amounts in bioanalysis and clinical biomedicine.

  18. Dual-peak electrogenerated chemiluminescence of carbon dots for iron ions detection.

    Science.gov (United States)

    Zhang, Pengjia; Xue, Zhenjie; Luo, Dan; Yu, Wei; Guo, Zhihui; Wang, Tie

    2014-06-17

    Carbon dots (CDs) have rigorously been investigated on their unique fluorescent properties but rarely their electrogenerated chemiluminescence (ECL) behavior. We are here to report a dual-peak ECL system of CDs, one at -2.84 V (ECL-1) and the other at -1.71 V (ECL-2) during the cyclic sweep between -3.0 and 3.0 V at scan rate of 0.2 V s(-1) in 0.1 M tetrabutyl ammonium bromide (TBAB) ethanol solution, which is more efficiency to distinguish metallic ions than single-peak ECL. The electron transfer reaction between individual electrochemically reduced nanocrystal species and coreactants led to ECL-1, in which the electron injected to the conduction band of CDs in the cathodic process. Ion annihilation reactions induced direct formation of exciplexes that produced another ECL signal, ECL-2. ECL-1 showed higher sensitivity to the surrounding environment than ECL-2 and thus was used for ECL detection of metallic ions. Herein, we can serve as an internal standard method to detect iron ions. A linear relationship of the intensity ratio R of ECL-1 and ECL-2 to iron ions was observed in the concentration extending from 5 × 10(-6) to 8 × 10(-5) M with a detection limit of 7 × 10(-7) M.

  19. Automated 3D-Printed Unibody Immunoarray for Chemiluminescence Detection of Cancer Biomarker Proteins

    Science.gov (United States)

    Tang, C. K.; Vaze, A.; Rusling, J. F.

    2017-01-01

    A low cost three-dimensional (3D) printed clear plastic microfluidic device was fabricated for fast, low cost automated protein detection. The unibody device features three reagent reservoirs, an efficient 3D network for passive mixing, and an optically transparent detection chamber housing a glass capture antibody array for measuring chemiluminescence output with a CCD camera. Sandwich type assays were built onto the glass arrays using a multi-labeled detection antibody-polyHRP (HRP = horseradish peroxidase). Total assay time was ~30 min in a complete automated assay employing a programmable syringe pump so that the protocol required minimal operator intervention. The device was used for multiplexed detection of prostate cancer biomarker proteins prostate specific antigen (PSA) and platelet factor 4 (PF-4). Detection limits of 0.5 pg mL−1 were achieved for these proteins in diluted serum with log dynamic ranges of four orders of magnitude. Good accuracy vs ELISA was validated by analyzing human serum samples. This prototype device holds good promise for further development as a point-of-care cancer diagnostics tool. PMID:28067370

  20. Novel assay of antibacterial components in manuka honey using lucigenin-chemiluminescence-HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Karasawa, Koji, E-mail: koji180@pharm.showa-u.ac.jp; Haraya, Shiomi; Okubo, Sachie; Arakawa, Hidetoshi

    2017-02-15

    Five components (hydrogen peroxide, methylglyoxal, dihydroxyacetone, fructose and glucose) of New Zealand manuka honey (Leptospermum scoparium) were analyzed using lucigenin chemiluminescence high-performance liquid chromatography (lucigenin-CL-HPLC). We focused on active oxygen species produced from the components in order to easily detect these five components contained in manuka honey. H{sub 2}O{sub 2} and O{sub 2}{sup −} generated from these components were identified by lucigenin-CL and electron spin resonance (ESR), and the bactericidal effect of ROS was confirmed using E. coli. The previously reported assays for Manuka honey components have low specificities and require complicated preprocessing methods. As our results, the detection and identification of these components were possible within 30 min in lucigenin-CL-HPLC system, without any special treatment. It is considered that lucigenin-CL-HPLC is useful for the quality control and the analysis of various honey. - Highlights: • Antibacterial components in manuka honey by HPLC with lucigenin-CL. • Five antibacterial compounds measured via generation of reactive oxygen species. • Simple, sensitive and useful for quality control and analysis of antibacterial honey.

  1. A signal-on electrogenerated chemiluminescent biosensor for lead ion based on DNAzyme

    International Nuclear Information System (INIS)

    Ma Fen; Sun Bo; Qi Honglan; Zhang Hongge; Gao Qiang; Zhang Chengxiao

    2011-01-01

    A highly reproducible and sensitive signal-on electrogenerated chemiluminescence (ECL) biosensor based on the DNAzyme for the determination of lead ion was developed. The ECL biosensor was fabricated by covalently coupling 5'-amino-DNAzyme-tagged with ruthenium bis (2,2'-bipyridine) (2,2'-bipyridine-4,4'-dicarboxylic acid)-ethylenediamine (Ru1-17E') onto the surface of graphite electrode modified with 4-aminobenzoic acid, and then a DNA substrate with a ribonucleotide adenosine hybridized with Ru1-17E' on the electrode. Upon binding of Pb 2+ to the Ru1-17E' to form a complex which catalyzed the cleavage of the DNA substrate, the double-stranded DNA was dissociated and thus led to a high ECL signal. The signal linearly increases with the concentration of Pb 2+ in the range from 5.0 to 80 pM with a detection limit of 1.4 pM and a relative standard derivation of 2.3%. This work demonstrates that using DNAzyme tagged with ruthenium complex as an ECL probe and covalently coupling method for the fabrication of the ECL biosensor with high sensitivity, good stability and significant regeneration ability is promising approach.

  2. Transfusion transmittable infections - Seroprevalence among blood donors in a tertiary care hospital of Delhi

    Directory of Open Access Journals (Sweden)

    Sangeeta Pathak

    2013-01-01

    Full Text Available Context: Transfusion transmittable infections (TTI continue to be a major threat to safe transfusion practices. Blood is one of the major sources of transmission of infectious diseases viz. human immunodeficiency virus (HIV, hepatitis B virus (HBV, hepatitis C virus (HCV, syphilis, malaria, and many other infections in India. Screening assays for the infectious diseases with excellent sensitivity and specificity helps to enhance the safety of the blood transfusions reducing the diagnostic window period as much as possible. Aims: The present study was designed to determine the seroprevalence of TTIs viz., HIV, HCV, and HBV, among the blood donors in Max Super Specialty Hospital, New Delhi, India based on dual testing strategy using high sensitive screening assays such as enhanced chemiluminescence assay and nucleic acid testing (NAT. Materials and Methods: A total of 41207 blood units collected from the donors (both voluntary and replacement donors were screened for the TTI s, viz., anti HIV 1 and 2 antibody, anti HCV antibody, anti HBcore antibody, and HBsAg by enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system. NAT was performed using Roche Cobas ® TaqScreen MPX assay, which can detect simultaneously HIV 1 (groups M and O, HIV-2, HCV, and HBV on Roche Cobas ® s201 system. Results: The seroprevalence of HIV, HBsAg, anti HBcore antibody, and HCV based on enhanced chemiluminescence assay was found to be 0.25, 0.2, 7.06, and 0.7%, respectively. A total number of 6587 samples from July 2010 to December 2010 were tested on NAT, of which 3 samples were reactive for HBV in NAT; this was missed by enhanced chemiluminescence assay. Conclusions: Based on the seroprevalence study of infectious diseases viz., HIV, HBV, and HCV, we conclude that screening of blood and blood components by dual testing strategy using high sensitivity serological assay like enhanced chemiluminescence technology and NAT helps in detecting the

  3. Performance evaluation of a novel chemiluminescence assay for detection of anti-GBM antibodies: an international multicenter study.

    Science.gov (United States)

    Mahler, Michael; Radice, Antonella; Sinico, Renato A; Damoiseaux, Jan; Seaman, Andrea; Buckmelter, Kristen; Vizjak, Alenka; Buchner, Carol; Binder, Walter L; Fritzler, Marvin J; Cui, Zhao

    2012-01-01

    Autoantibodies to the non-collagen region (NC1) of the alpha-3 subunit of collagen IV represent a serological hallmark in the diagnosis of Goodpasture's syndrome (GPS). The objective of our study was to carefully analyze the performance characteristics of a novel anti-glomerular basement membrane (GBM) chemiluminescence immunoassay (CIA). Sera from patients with GPS (n = 90) were collected from four clinical centers. Samples from different disease groups (n = 397) and healthy individuals (n = 400) were used as controls. All samples were tested for anti-GBM antibodies by a rapid, random access CIA (QUANTA Flash™ GBM). Most of the samples were also tested using other methods including different commercial anti-GBM IgG assays and research assays for anti-GBM IgA and IgM. The sensitivity and specificity of the novel CIA was 95.6% [95% confidence interval (CI) 89.0-98.8%] and 99.6% (95% CI 98.9-99.9%), respectively. Receiver operating characteristic analysis showed good discrimination between GPS patients and controls. The area under the curve was 0.98 (CI 0.96-1.0). The three anti-GBM antibody-positive samples from the control group were from two healthy individuals and one human immunodeficiency virus (HIV)-infected patient. All three individuals had low levels of anti-GBM antibodies [20, 24 and 25 chemiluminescent unit (CU), cutoff 20 CU]. When the results of the new CIA were compared to other methods, good agreement was observed: 95.8% (kappa = 0.92) versus EliA™ GBM, 97.4% (kappa = 0.95) versus both BINDAZYME™ Anti-GBM and QUANTA Lite® GBM. Anti-GBM IgA was detectable in low concentrations in patients with GPS and was associated with anti-GBM IgG but was less useful in discriminating GPS patients and controls. No discrimination was found for anti-GBM IgM. The novel QUANTA Flash™ GBM CIA demonstrated good sensitivity and specificity and had good agreement with other methods. Our data confirm that ∼5% of patients with GPS do not have detectable levels of

  4. Synthesis, Photophysics, Electrochemistry and Electrogenerated Chemiluminescence of a Homologous Set of BODIPY-Appended Bipyridine Derivatives.

    Science.gov (United States)

    Rosenthal, Joel; Nepomnyashchii, Alexander B; Kozhukh, Julia; Bard, Allen J; Lippard, Stephen J

    2011-09-15

    Two new 2,2'-bipyridine (bpy) based ligands with ancillary BODIPY chromophores attached at the 4 and 4'-positions were prepared and characterized, which vary in the substitution pattern about the BODIPY periphery by either excluding (BB1) or including (BB2) a β-alkyl substituent. Both absorb strongly throughout the visible region and are strongly emissive. The basic photophysics and electrochemical properties of BB1 and BB2 are comparable to those of the BODIPY monomers on which they are based. The solid-state structures and electronic structure calculations both indicate that there is negligible electronic communication between the BODIPY moieties and the intervening bpy spacers. Electrogenerated chemiluminescence spectra of the two Bpy-BODIPY derivatives are similar to their recorded fluorescence profiles and are strongly influenced by substituents on the BODIPY chromophores. These 2,2'-bipyridine derivatives represent a new set of ligands that should find utility in applications including light-harvesting, photocatalysis, and molecular electronics.

  5. Flow injection chemiluminescent determination of N-nitrosodimethylamine using photogenerated tris(2,2'-bipyridyl) ruthenium (III)

    International Nuclear Information System (INIS)

    Perez-Ruiz, Tomas; Martinez-Lozano, Carmen; Tomas, Virginia; Martin, Jesus

    2005-01-01

    A flow injection configuration was developed and evaluated for the chemiluminescent determination of N-nitrosodimethylamine. The method is based on the on-line cleavage of the N-NO bond of the nitrosamine by irradiation with ultraviolet light. The dimethylamine generated was subsequently reacted with tris(2,2'-bipyridyl) ruthenium (III), which was generated through the on-line photo-oxidation of tris(2,2'-bipyridyl) ruthenium (II) with peroxydisulfate. After selecting the best operating parameters, the emitted light showed a linear relationship with the concentration of N-nitrosodimethylamine between 1.5 and 148 ng ml -1 , with a detection limit of 0.29 ng ml -1 . The repeatability was 1.6% expressed as relative standard deviation (n = 10) and the reproducibility, studied on five consecutive days, was 3.2%. The sample throughput was 50 injections per hour. The method was applied to studying the recoveries of N-nitrosodimethylamine in water and different cured meat products

  6. Low level chemiluminescence measurement of the binding of 8-methoxypsoralen to proteins and lymphocytic surfaces

    International Nuclear Information System (INIS)

    Lange, B.

    1980-01-01

    Photochemotherapy with 8-methoxypsoralen (8-MOP) and longwave ultraviolet light is beneficial in such different disorders like psoriasis, lichen planus, and mykosis fungoides. In contrast to a widely accepted hypothesis 8-MOP does not solely bind to nucleic acid, but also to certain proteins. The mechanism of this binding as well as the precise binding area are unknown. Therefore the UV-provoked reactions of 8-MOP with a lipid mixture, a glucosaminoglycan solution, a protein solution, and lymphocyte suspensions, respectively were investigated using low level chemiluminescence (LLCL). It was found an 8-MOP concentration-dependent decrease of LLCL intensity in the lymphocyte suspensions (10 3 to 10 4 cells/μl). This effect is result of the diminution of the photoactive 8-MOP content of the solution. 8-MOP binds quickly and in the course of a free radical reaction to lymphocytic surfaces and coincidentally loses its potency to start LLCL-detectable free radical chain responses. (author)

  7. Clinical significance of quantitative analysis of thyroid peroxidase antibody (TPOAb) with chemiluminescence enzyme immunoassay

    International Nuclear Information System (INIS)

    Zhu Cuiying; Wang Qing; Huang Gang

    2004-01-01

    Objective: The only method of laboratory diagnosis for autoimmune thyroid diseases used to be serum TGA and TMA detections. Morerecently, quantitative analysis of TPOAb has been introduced. To assess the relative sensitivity of these tests , positive rates detected with the respective tests were compared. Methods: Serum TGA, TMA (with RIA) and TPOAb (with chemiluminescence enzyme immunoassay) were simultaneously detected in 998 cases of thyroid diseases (hyperthyroidism 307, Hashimoto's disease 193, simple goiter 498). For complementary sake, fine needle aspiration cytology was obtained in a number of cases including all the patients with Hashimoto's disease. Results: Positive detection rate of TPOAb in three groups of patients (hyperthyroidism, Hashimoto's, simple goiter) was 81.76%, 96.89 % and 42.97% respectively. With TMA, the positive rate was only 54.72%, 65.80%, 22.09% respectively. About one third more cases would be detected with the newer method. Conclusion: For the laboratory detection of auto immune thyroid diseases, quantitative analysis of TPOAb is much wore sensitive than the conventional TMA detection. (authors)

  8. Plasma treatment of paper for protein immobilization on paper-based chemiluminescence immunodevice.

    Science.gov (United States)

    Zhao, Mei; Li, Huifang; Liu, Wei; Guo, Yumei; Chu, Weiru

    2016-05-15

    A novel protein immobilization method based on plasma treatment of paper on the low-cost paper-based immunodevice was established in this work. By using a benchtop plasma cleaner, the paper microzone was treated by oxygen plasma treatment for 4 min and then the antibody can be directly immobilized on the paper surface. Aldehyde group was produced after the plasma treatment, which can be verified from the fourier transform infrared spectroscopy (FT-IR) spectra and x-ray photoelectron spectroscopy (XPS) spectra. By linked to aldehyde group, the antibody can be immobilized on the paper surface without any other pretreatment. A paper-based immunodevice was introduced here through this antibody immobilization method. With sandwich chemiluminescence (CL) immunoassay method, the paper-based immunodevice was successfully performed for carcinoembryonic antigen (CEA) detection in human serum with a linear range of 0.1-80.0 ng/mL. The detection limit was 0.03 ng/mL, which was 30 times lower than the clinical CEA level. Comparing to the other protein immobilization methods on paper-based device, this strategy was faster and simpler and had potential applications in point-of-care testing, public health and environmental monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. An in-fiber integrated optofluidic device based on an optical fiber with an inner core.

    Science.gov (United States)

    Yang, Xinghua; Yuan, Tingting; Teng, Pingping; Kong, Depeng; Liu, Chunlan; Li, Entao; Zhao, Enming; Tong, Chengguo; Yuan, Libo

    2014-06-21

    A new kind of optofluidic in-fiber integrated device based on a specially designed hollow optical fiber with an inner core is designed. The inlets and outlets are built by etching the surface of the optical fiber without damaging the inner core. A reaction region between the end of the fiber and a solid point obtained after melting is constructed. By injecting samples into the fiber, the liquids can form steady microflows and react in the region. Simultaneously, the emission from the chemiluminescence reaction can be detected from the remote end of the optical fiber through evanescent field coupling. The concentration of ascorbic acid (AA or vitamin C, Vc) is determined by the emission intensity of the reaction of Vc, H2O2, luminol, and K3Fe(CN)6 in the optical fiber. A linear sensing range of 0.1-3.0 mmol L(-1) for Vc is obtained. The emission intensity can be determined within 2 s at a total flow rate of 150 μL min(-1). Significantly, this work presents information for the in-fiber integrated optofluidic devices without spatial optical coupling.

  10. Design of a sensitive aptasensor based on magnetic microbeads-assisted strand displacement amplification and target recycling.

    Science.gov (United States)

    Li, Ying; Ji, Xiaoting; Song, Weiling; Guo, Yingshu

    2013-04-03

    A cross-circular amplification system for sensitive detection of adenosine triphosphate (ATP) in cancer cells was developed based on aptamer-target interaction, magnetic microbeads (MBs)-assisted strand displacement amplification and target recycling. Here we described a new recognition probe possessing two parts, the ATP aptamer and the extension part. The recognition probe was firstly immobilized on the surface of MBs and hybridized with its complementary sequence to form a duplex. When combined with ATP, the probe changed its conformation, revealing the extension part in single-strand form, which further served as a toehold for subsequent target recycling. The released complementary sequence of the probe acted as the catalyst of the MB-assisted strand displacement reaction. Incorporated with target recycling, a large amount of biotin-tagged MB complexes were formed to stimulate the generation of chemiluminescence (CL) signal in the presence of luminol and H2O2 by incorporating with streptavidin-HRP, reaching a detection limit of ATP as low as 6.1×10(-10)M. Moreover, sample assays of ATP in Ramos Burkitt's lymphoma B cells were performed, which confirmed the reliability and practicality of the protocol. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Branched nanotrees with immobilized acetylcholine esterase for nanobiosensor applications

    Energy Technology Data Exchange (ETDEWEB)

    Risveden, Klas; Bhand, Sunil; Danielsson, Bengt [Department of Pure and Applied Biochemistry, Center for Chemistry and Chemical Engineering, Lund University, PO Box 124, SE-22100 Lund (Sweden); Dick, Kimberly A; Samuelson, Lars [Solid State Physics, Lund University, Box 118, S-22100 Lund (Sweden); Rydberg, Patrik, E-mail: Kimberly.Dick@ftf.lth.se [Department of Medicinal Chemistry, Faculty of Pharmaceutical Sciences, University of Copenhagen, Universitetsparken 2, DK-2100 Copenhagen (Denmark)

    2010-02-05

    A novel lab-on-a-chip nanotree enzyme reactor is demonstrated for the detection of acetylcholine. The reactors are intended for use in the RISFET (regional ion sensitive field effect transistor) nanosensor, and are constructed from gold-tipped branched nanorod structures grown on SiN{sub x}-covered wafers. Two different reactors are shown: one with simple, one-dimensional nanorods and one with branched nanorod structures (nanotrees). Significantly higher enzymatic activity is found for the nanotree reactors than for the nanorod reactors, most likely due to the increased gold surface area and thereby higher enzyme binding capacity. A theoretical calculation is included to show how the enzyme kinetics and hence the sensitivity can be influenced and increased by the control of electrical fields in relation to the active sites of enzymes in an electronic biosensor. The possible effects of electrical fields employed in the RISFET on the function of acetylcholine esterase is investigated using quantum chemical methods, which show that the small electric field strengths used are unlikely to affect enzyme kinetics. Acetylcholine esterase activity is determined using choline oxidase and peroxidase by measuring the amount of choline formed using the chemiluminescent luminol reaction.

  12. Universal chemiluminescence flow-through device based on directed self-assembly of solid-state organic chromophores on layered double hydroxide matrix.

    Science.gov (United States)

    Wang, Zhihua; Teng, Xu; Lu, Chao

    2013-02-19

    In this work, a universal chemiluminescence (CL) flow-through device suitable for various CL resonance energy transfer (CRET) systems has been successfully fabricated. Highly efficient CRET in solid-state photoactive organic molecules can be achieved by assembling them on the surface of layered double hydroxides (LDHs). We attribute these observations to the suppression of the intermolecular π-π stacking interactions among aromatic rings and the improvement of molecular orientation and planarity in the LDH matrix, enabling a remarkable increase in fluorescence lifetime and quantum yield of organic molecules. Under optimal conditions, using peroxynitrous acid-fluorescein dianion (FLUD) as a model CRET system, trace FLUD (10 μM) was assembled on the surface of LDHs. Peroxynitrous acid/nitrite could be assayed in the range of 1.0-500 μM, and the detection limit for peroxynitrous acid/nitrite (S/N = 3) was 0.6 μM. This CL flow-through device exhibited operational stability, high reproducibility, and long lifetime. While LDHs were immobilized in a flow-through device in the absence of FLUD, the detection limit for peroxynitrous acid/nitrite was 100 μM. On the other hand, FLUD at the same concentration can not enhance the CL intensity of peroxynitrous acid system. This fabricated CL flow-through column has been successfully applied to determine nitrite in sausage samples with recoveries of 98-102%. These satisfactory results demonstrated that our studies pave a novel way toward flow-through column-based CRET using solid-state organic molecules as acceptors for signal amplification.

  13. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer.

    Science.gov (United States)

    Fu, Xiaoling; Liu, Yangyang; Qiu, Ruiyun; Foda, Mohamed F; Zhang, Yong; Wang, Tao; Li, Jinshan

    2018-03-01

    The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA) was presented for the clinical determination and analysis of human epididymis protein 4 (HE4) in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0-1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA), with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum.

  14. [Establishment of chemiluminescent enzyme immunoassay for detecting antibodies against foot-and-mouth disease virus serotype O in swine].

    Science.gov (United States)

    Cui, Chen; Huang, Ligang; Li, Jing; Zou, Xingqi; Zhu, Yuanyuan; Xie, Lei; Zhao, Qizu; Yang, Limin; Liu, Wenjun

    2016-11-25

    Recombinant structural protein VP1 of foot-and-mouth disease virus serotype O was expressed in Escherichia coli and then purified using Nickel affinity chromatography. A chemiluminescent enzyme immunoassay (CLEIA) method was established using the purified recombinant protein as coating antigen to detect antibody of foot-and-mouth disease virus serotype O in swine. The specificity of VP1-CLEIA method is 100%. The coefficients of variation in the plate and between plates are 1.10%-6.70% and 0.66%-4.80%, respectively. Comparing with the commercial indirect ELISA kit or liquid phase block ELISA kit, the calculated coincidence rate is 93.50% or 94.00%. The high specificity and stability suggested this detection method can be used to monitor the antibody level of foot-and-mouth disease virus serotype O in swine.

  15. Thermoluminescence and chemiluminescence measurement as routine screening method for identification of irradiated spices. Studies to establish limiting values for differentiation of irradiated and non-irradiated samples. Thermolumineszenz- und Chemilumineszenzmessungen als Routine-Methoden zur Identifizierung strahlenbehandelter Gewuerze. Untersuchungen zur Festlegung von Grenzwerten fuer die Unterscheidung bestrahlter von unbestrahlten Proben

    Energy Technology Data Exchange (ETDEWEB)

    Heide, L; Albrich, S; Mentele, E; Boegl, W

    1987-04-01

    The reported experiments with non-irradiated and ..gamma..-irradiated spices of different origin were conducted to determine the variation in chemiluminescence and thermoluminescence intensity for each individual spice. 29 spices from 7 to 10 different manufacturers have been examined, taking into account the influence of storage time. In order to evaluate the methods, the results are represented in diagrams and tables enabling light emission limits to be given for differentiation between irradiated and non-irradiated samples. The final section of this report contains a conclusive evaluation of the present state of chemiluminescence and thermoluminescence analysis for the detection of irradiated spices.

  16. Live Candida albicans Suppresses Production of Reactive Oxygen Species in Phagocytes▿ †

    Science.gov (United States)

    Wellington, Melanie; Dolan, Kristy; Krysan, Damian J.

    2009-01-01

    Production of reactive oxygen species (ROS) is an important aspect of phagocyte-mediated host responses. Since phagocytes play a crucial role in the host response to Candida albicans, we examined the ability of Candida to modulate phagocyte ROS production. ROS production was measured in the murine macrophage cell line J774 and in primary phagocytes using luminol-enhanced chemiluminescence. J774 cells, murine polymorphonuclear leukocytes (PMN), human monocytes, and human PMN treated with live C. albicans produced significantly less ROS than phagocytes treated with heat-killed C. albicans. Live C. albicans also suppressed ROS production in murine bone marrow-derived macrophages from C57BL/6 mice, but not from BALB/c mice. Live C. albicans also suppressed ROS in response to external stimuli. C. albicans and Candida glabrata suppressed ROS production by phagocytes, whereas Saccharomyces cerevisiae stimulated ROS production. The cell wall is the initial point of contact between Candida and phagocytes, but isolated cell walls from both heat-killed and live C. albicans stimulated ROS production. Heat-killed C. albicans has increased surface exposure of 1,3-β-glucan, a cell wall component that can stimulate phagocytes. To determine whether surface 1,3-β-glucan exposure accounted for the difference in ROS production, live C. albicans cells were treated with a sublethal dose of caspofungin to increase surface 1,3-β-glucan exposure. Caspofungin-treated C. albicans was fully able to suppress ROS production, indicating that suppression of ROS overrides stimulatory signals from 1,3-β-glucan. These studies indicate that live C. albicans actively suppresses ROS production in phagocytes in vitro, which may represent an important immune evasion mechanism. PMID:18981256

  17. Determination of itopride hydrochloride by high-performance liquid chromatography with Ru(bpy)3(2+) electrogenerated chemiluminescence detection.

    Science.gov (United States)

    Sun, Yonghua; Zhang, Zhujun; Xi, Zhijun; Shi, Zuolong; Tian, Wei

    2009-08-26

    In this work, a stable electrogenerated chemiluminescence (ECL) detector was developed. The detector was prepared by packing cation-exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)(3)(2+) can be compensated by adding a small amount of Ru(bpy)(3)(2+) into solution phase. Coupled with high-performance liquid chromatography separation, the detector has been used for determination of itopride hydrochloride in human serum. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of itopride hydrochloride in the range of 1.0 x 10(-8) g mL(-1) to 1.0 x 10(-6) g mL(-1) and the detection limit was 3 x 10(-9) g mL(-1) (S/N=3). The as-prepared ECL detector displayed good sensitivity and stability.

  18. Chemiluminescence generation and detection in a capillary-driven microfluidic chip

    Science.gov (United States)

    Ramon, Charlotte; Temiz, Yuksel; Delamarche, Emmanuel

    2017-02-01

    The use of microfluidic technology represents a strong opportunity for providing sensitive, low-cost and rapid diagnosis at the point-of-care and such a technology might therefore support better, faster and more efficient diagnosis and treatment of patients at home and in healthcare settings both in developed and developing countries. In this work, we consider luminescence-based assays as an alternative to well-established fluorescence-based systems because luminescence does not require a light source or expensive optical components and is therefore a promising detection method for point-of-care applications. Here, we show a proof-of-concept of chemiluminescence (CL) generation and detection in a capillary-driven microfluidic chip for potential immunoassay applications. We employed a commercial acridan-based reaction, which is catalyzed by horseradish peroxidase (HRP). We investigated CL generation under flow conditions using a simplified immunoassay model where HRP is used instead of the complete sandwich immunocomplex. First, CL signals were generated in a capillary microfluidic chip by immobilizing HRP on a polydimethylsiloxane (PDMS) sealing layer using stencil deposition and flowing CL substrate through the hydrophilic channels. CL signals were detected using a compact (only 5×5×2.5 cm3) and custom-designed scanner, which was assembled for less than $30 and comprised a 128×1 photodiode array, a mini stepper motor, an Arduino microcontroller, and a 3D-printed housing. In addition, microfluidic chips having specific 30-μm-deep structures were fabricated and used to immobilize ensembles of 4.50 μm beads functionalized with HRP so as to generate high CL signals from capillary-driven chips.

  19. A fast and precise chemiluminescence ozone detector for eddy flux and airborne application

    Directory of Open Access Journals (Sweden)

    A. Zahn

    2012-02-01

    Full Text Available A commercially available dry chemiluminescence (CI instrument for fast and precise measurement of ozone (O3 is specified. The sensitivity is ~9000 counts s−1 per ppbv of ozone. Its precision is entirely determined by the number of photons reaching the detector (being a photomultiplier, i.e. is quantum-noise limited. The relative precision (ΔO3/O3 in % thus follows Poisson statistics and scales with the square root of the measurement frequency f and with the inverse O3 mixing ratio: ΔO3/O3f0.5 · O3−0.5. At typical O3 mixing ratios between 10 and 100 ppbv (and 1 bar, the precision is 0.3–1.0% at f = 10 Hz. The maximum measurement frequency is 50 Hz. The mechanical and electronic set-up as well as the instrument performance is described. Recommendations on the adequate inlet tube configuration (inlet tube length, sampling flow and on the way of calibration at stationary ground-based platforms and onboard aircraft are given.

  20. A simple and sensitive flow injection method based on the catalytic activity of CdS quantum dots in an acidic permanganate chemiluminescence system for determination of formaldehyde in water and wastewater.

    Science.gov (United States)

    Khataee, Alireza; Lotfi, Roya; Hasanzadeh, Aliyeh; Iranifam, Mortaza

    2016-04-01

    A simple and sensitive flow injection chemiluminescence (CL) method in which CdS quantum dots (QDs) enhanced the CL intensity of a KMnO4-formaldehyde (HCHO) reaction was offered for the determination of HCHO. This CL system was based on the catalytic activity of CdS QDs and their participation in the CL resonance energy transfer (CRET) phenomenon. A possible mechanism for the supplied CL system was proposed using the kinetic curves of the CL systems and the spectra of CL, photoluminescence (PL) and ultraviolet-visible (UV-Vis). The emanated CL intensity of the KMnO4-CdS QDs system was amplified in the presence of a trace level of HCHO. Based on this enhancement effect, a simple and sensitive flow injection CL method was suggested for the determination of HCHO concentration in environmental water and wastewater samples. Under selected optimized experimental conditions, the increased CL intensity was proportional to the HCHO concentration in the range of 0.03-4.5 μg L(-1) and 4.5-10.0 μg L(-1). The detection limits (3σ) were 0.0003 μg L(-1) and 1.2 μg L(-1). The relative standard deviations (RSD%) for eleven replicate determinations of 4.0 μg L(-1) HCHO were 2.2%. Furthermore, the feasibility of the developed method was investigated via the determination of HCHO concentration in environmental water and wastewater samples.

  1. The Use of Flow-Injection Analysis with Chemiluminescence Detection of Aqueous Ferrous Iron in Waters Containing High Concentrations of Organic Compounds

    Directory of Open Access Journals (Sweden)

    Carrick M. Eggleston

    2009-06-01

    Full Text Available An evaluation of flow-injection analysis with chemiluminescence detection (FIA-CL to quantify Fe2+(aq in freshwaters was performed. Iron-coordinating and/or iron-reducing compounds, dissolved organic matter (DOM, and samples from two natural water systems were used to amend standard solutions of Fe2+(aq. Slopes of the response curves from ferrous iron standards (1 – 100 nM were compared to the response curves of iron standards containing the amendments. Results suggest that FIA-CL is not suitable for systems containing ascorbate, hydroxylamine, cysteine or DOM. Little or no change in sensitivity occurred in solutions of oxalate and glycine or in natural waters with little organic matter.

  2. Layered double hydroxide-enhanced luminescence in a Fenton-like system for selective sensing of cobalt in Hela cells

    Science.gov (United States)

    Yu, Mei; Yuan, Zhiqin; Lu, Chao

    2017-09-01

    This work presented a facile and eco-friendly method for the determination of cobalt ions (Co(II)) in living cells based on layered double hydroxides (Mg-Al CO3-LDHs) enhanced chemiluminescence (CL) emission of a Co(II)-hydrogen peroxide-sodium hydroxide system. The enhanced CL emission was attributed to the large specific surface area of Mg-Al CO3-LDHs, which facilitates the generation of an excited-stated intermediate. The proposed method displayed high selectivity toward Co(II) over other metal ions. Under the optimal conditions, the increased CL intensity showed a linear response versus Co(II) concentration in the range of 5.0-1000 nM with a detection limit of 3.7 nM (S/N = 3). The relative standard deviation for nine repeated measurements of 100 nM Co(II) was 3.2%. Furthermore, the proposed method was successfully applied to detect Co(II) in living cell samples, and the results were agreed with those obtained by the standard ICP-MS method.

  3. Chemiluminescence from an oxidation reaction of rhodamine B with cerium(IV) in a reversed micellar medium of cetyltrimethylammonium chloride in 1-hexanol-cyclohexane/water.

    Science.gov (United States)

    Hasanin, Tamer H A; Tsunemine, Yusuke; Tsukahara, Satoshi; Okamoto, Yasuaki; Fujiwara, Terufumi

    2011-01-01

    The chemiluminescence (CL) emission, observed when rhodamine B (RB) in 1-hexanol-cyclohexane was mixed with cerium(IV) sulfate in sulfuric acid dispersed in a reversed micellar medium of cetyltrimethylammonium chloride (CTAC) in 1-hexanol-cyclohexane/water, was investigated using a flow-injection system. The CL emission from the oxidation reaction of RB with Ce(IV) was found to be stronger in the CTAC reversed micellar solution compared with an aqueous solution. Bearing on the enhancement effect of the CTAC reverse micelles on the RB-Ce(IV) CL, several studies including stopped-flow, fluorescence and electron spin resonance (ESR) spectrometries were performed. Rapid spectral changes of an intermediate in the RB-Ce(IV) reaction in the aqueous and reversed micellar solutions were successfully observed using a stopped-flow method. The effect of the experimental variables, i.e., oxidant concentration, sulfuric acid concentration, the mole fraction of 1-hexanol, water-to-surfactant molar concentration ratio, flow rate, upon the CL intensity was evaluated. Under the experimental conditions optimized for a flow-injection determination of RB based on the new reversed micellar-mediated CL reaction with Ce(IV), a detection limit of 0.08 µmol dm(-3) RB was achieved, and a linear calibration graph was obtained with a dynamic range from 0.5 to 20 µmol dm(-3). The relative standard deviation (n = 6) obtained at an RB concentration of 3 µmol dm(-3) was 3%.

  4. Electrogenerated chemiluminescence of tris(2,2' bipyridine)ruthenium(II) using common biological buffers as co-reactant, pH buffer and supporting electrolyte.

    Science.gov (United States)

    Kebede, Noah; Francis, Paul S; Barbante, Gregory J; Hogan, Conor F

    2015-11-07

    A series of aliphatic tertiary amines (HEPES, POPSO, EPPS and BIS-TRIS) commonly used to buffer the pH in biological experiments, were examined as alternative, non-toxic co-reactants for the electrogenerated chemiluminescence (ECL) of tris(2,2'-bipyridine)ruthenium(ii) ([Ru(bpy)3](2+)). These were found to be very attractive as "multi-tasking" reagents, serving not only as co-reactants, but also fulfiling the roles of pH buffer and supporting electrolyte within an aqueous environment; thus significantly simplifying the overall ECL analysis. Sub-nanomolar detection limits were obtained for [Ru(bpy)3](2+) in the presence of BIS-TRIS, making this species an valuable option for co-reactant ECL-based bioanalytical applications.

  5. Quenching the chemiluminescence of acridinium ester by graphene oxide for label-free and homogeneous DNA detection.

    Science.gov (United States)

    He, Yi; Huang, Guangming; Cui, Hua

    2013-11-13

    It was found that graphene oxide (GO) could effectively quench the chemiluminescence (CL) emission from a acridinium ester (AE)-hydrogen peroxide system. By taking advantage of this quenching effect, as a proof of concept, a label-free and homogeneous DNA assay was developed for the detection of Mycobacterium tuberculosis DNA. In the absence of target DNA, both probe DNA and AE were absorbed on the surface of GO, producing a weak CL emission owing to the CL quenching effect of GO. However, in the presence of target DNA, a double-stranded structure of DNA was generated, leading to the release of the oligonucleotide from the GO surface. AE favors binding with double-stranded DNA, which will be released from the GO surface; thus, the quenching effect of GO will be no longer effective and a strong CL signal can be observed. This assay can detect M. tuberculosis DNA with a detection limit of 0.65 nM. This sensitivity is lower than that of previously reported electrochemical detection.

  6. Determination of volatile nitrosamines in grilled lamb and vegetables using comprehensive gas chromatography - nitrogen chemiluminescence detection.

    Science.gov (United States)

    Kocak, D; Ozel, M Z; Gogus, F; Hamilton, J F; Lewis, A C

    2012-12-15

    The grilling of meat may generate dangerous levels of mutagenic and carcinogenic nitrosamines (NAs). Meat and vegetable samples underwent a two-step solid-phase extraction before analysis by comprehensive gas chromatography with a nitrogen chemiluminescence detection system (GCxGC-NCD). The GCxGC-NCD method showed high selectivity, sensitivity and equimolarity in its response to six specific NAs. NA contamination of charcoal-grilled lamb at various stages of cooking and with various fat contents and also charcoal-grilled vegetables were investigated. The grilling of lamb on unready charcoal resulted in the formation of considerable quantities of NAs. Grilling lamb on properly prepared, ready charcoal resulted in an increase in total concentrations of six NAs from 0 to 4.51 μg kg(-1) over a period of 16 min. Increasing the fat content of the grilled lamb from 5% to 20% caused a modest increase in total concentrations of the six investigated NAs from 4.51 to 5.30 μg kg(-1). Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Electrospun gelatin/sodium bicarbonate and poly(lactide-co-ε-caprolactone)/sodium bicarbonate nanofibers as drug delivery systems.

    Science.gov (United States)

    Sang, Qingqing; Williams, Gareth R; Wu, Huanling; Liu, Kailin; Li, Heyu; Zhu, Li-Min

    2017-12-01

    In this work, we report electrospun nanofibers made of model hydrophobic (poly(lactide-co-ε-caprolactone); PLCL) and hydrophilic (gelatin) polymers. We explored the effect on drug release of the incorporation of sodium bicarbonate (SB) into these fibers, using the potent antibacterial agent ciprofloxacin as a model drug. The fibers prepared are smooth and have relatively uniform diameters lying between ca. 600 and 850nm. The presence of ciprofloxacin in the fibers was confirmed using IR spectroscopy. X-ray diffraction showed the drug to be incorporated into the fibers in the amorphous form. In vitro drug release studies revealed that, as expected, more rapid drug release was seen with gelatin fibers than those made of PLCL, and a greater final release percentage was obtained. The inclusion of SB in the gelatin fibers imparts them with pH sensitivity: gelatin/SB fibers showed faster release at pH5 than pH7.4, while fibers without SB gave the same release profiles at both pHs. The PLCL fibers have no pH sensitivity, even when SB was included, as a result of their hydrophobic structure precluding the ingress of solvent. In vitro cell culture studies showed that all the fibers are able to promote cell proliferation. The ciprofloxacin loaded fibers are effective in inhibiting Escherichia coli and Staphylococcus aureus growth in antibacterial tests. Thus, the gelatin-based fibers can be used as pH-responsive drug delivery systems, with potential applications for instance in the treatment of tumor resection sites. Should these become infected, the pH would drop, resulting in ciprofloxacin being released and the infection halted. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  8. A charged aerosol detector/chemiluminescent nitrogen detector/liquid chromatography/mass spectrometry system for regular and fragment compound analysis in drug discovery.

    Science.gov (United States)

    Jiang, Yutao; Hascall, Daniel; Li, Delia; Pease, Joseph H

    2015-09-11

    In this paper, we introduce a high throughput LCMS/UV/CAD/CLND system that improves upon previously reported systems by increasing both the quantitation accuracy and the range of compounds amenable to testing, in particular, low molecular weight "fragment" compounds. This system consists of a charged aerosol detector (CAD) and chemiluminescent nitrogen detector (CLND) added to a LCMS/UV system. Our results show that the addition of CAD and CLND to LCMS/UV is more reliable for concentration determination for a wider range of compounds than either detector alone. Our setup also allows for the parallel analysis of each sample by all four detectors and so does not significantly increase run time per sample. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Electrochemiluminescence and chemiluminescence of a carboxylic acid derivative of ruthenium(II) tris-(2,2'-bipyridine) chelate synthesized for labeling purposes

    International Nuclear Information System (INIS)

    Jiang Qinghong; Sun Shiguo; Hakansson, Markus; Langel, Kaarina; Ylinen, Tiina; Suomi, Johanna; Kulmala, Sakari

    2006-01-01

    Synthesis, purification and characterization of [4-ethoxycarbonyl-4'-carboxy-2,2'-bipyridine]bis(2,2'-bipyridine) ruthenium(II) hexafluorophosphate is described. This complex is shown to be electrochemiluminescent in aqueous solution during cathodic pulse polarization of thin insulating film-coated electrodes. Electrochemiluminescence (ECL) lifetime of the complex was observed to be ca. 40 μs at oxide-coated n-silicon electrodes; thus time-resolved detection is also possible. The ECL emission maximum of this carboxylate derivative is somewhat red-shifted when compared with an unmodified Ru(bpy) 3 2+ . Because the present complex can be easily covalently coupled with antibodies and oligonucleotides it is usable as an electrochemiluminescent label in various bioaffinity assays. The present chelates also produce strong chemiluminescence during dissolution of metallic magnesium in aqueous solution

  10. Heterogeneity of neutrophil antibodies in patients with primary Sjögren's syndrome.

    Science.gov (United States)

    Lamour, A; Le Corre, R; Pennec, Y L; Cartron, J; Youinou, P

    1995-11-01

    Our aims were to determine the prevalence of neutrophil antibodies in patients with primary Sjögren's syndrome (pSS), identify their target antigen(s), and evaluate their functional significance. Neutrophil antibodies were detected using an indirect immunofluorescence (IIIF) test and an enzyme-linked immunosorbent assay (ELISA), using recombinant human Fc-gamma receptor (Fc gamma RIIIb) as a capture agent. Luminol-dependent chemiluminescence was then measured by an established technique. Antibodies to neutrophils were detected in 30 of 66 patients (45%) and categorized on the basis of positivity for the two assays: IIF+/ELISA+ (group A: five patients), IIF+/ELISA- (group B: five patients), and IFF-/ELISA+ (group C: 20 patients). All positive sera contained antibodies directed to the neutrophil specific Fc gamma RIIIb, and none of them bound to NAnull neutrophils. The titer of neutrophil-reactive antibodies (groups A and B) showed no correlation with the neutrophil count, but these autoantibodies did reduce the cell ability to generate a respiratory burst. Thus, neutrophil antibodies are common in patients with pSS. Their main target appears to be Fc gamma RIII, and this may partly account for the dysfunction in Fc gamma R-mediated clearance by the reticuloendothelial system reported in these patients.

  11. Oxidative response of neutrophils to platelet-activating factor is altered during acute ruminal acidosis induced by oligofructose in heifers.

    Science.gov (United States)

    Concha, Claudia; Carretta, María Daniella; Alarcón, Pablo; Conejeros, Ivan; Gallardo, Diego; Hidalgo, Alejandra Isabel; Tadich, Nestor; Cáceres, Dante Daniel; Hidalgo, María Angélica; Burgos, Rafael Agustín

    2014-01-01

    Reactive oxygen species (ROS) production is one of the main mechanisms used to kill microbes during innate immune response. D-lactic acid, which is augmented during acute ruminal acidosis, reduces platelet activating factor (PAF)-induced ROS production and L-selectin shedding in bovine neutrophils in vitro. This study was conducted to investigate whether acute ruminal acidosis induced by acute oligofructose overload in heifers interferes with ROS production and L-selectin shedding in blood neutrophils. Blood neutrophils and plasma were obtained by jugular venipuncture, while ruminal samples were collected using rumenocentesis. Lactic acid from plasma and ruminal samples was measured by HPLC. PAF-induced ROS production and L-selectin shedding were measured in vitro in bovine neutrophils by a luminol chemiluminescence assay and flow cytometry, respectively. A significant increase in ruminal and plasma lactic acid was recorded in these animals. Specifically, a decrease in PAF-induced ROS production was observed 8 h after oligofructose overload, and this was sustained until 48 h post oligofructose overload. A reduction in PAF-induced L-selectin shedding was observed at 16 h and 32 h post oligofructose overload. Overall, the results indicated that neutrophil PAF responses were altered in heifers with ruminal acidosis, suggesting a potential dysfunction of the innate immune response.

  12. Soil emissions of nitric oxide in a seasonally dry tropical forest of Mexico

    Science.gov (United States)

    Davidson, Eric A.; Vitousek, Peter M.; Riley, Ralph; Matson, Pamela A.; Garcia-Mendez, Georgina; Maass, J. M.

    1991-01-01

    Soil emissions of NO were measured at the Chamela Biological Station, Mexico, using soil covers and a field apparatus of NO detection based on CrO3 conversion of NO to NO2 and detection of NO2 by chemiluminescence with Luminol. Mean NO fluxes from forest soils ranged from 0.14 to 0.52 ng NO-N/sq cm/hr during the dry season and from 0.73 to 1.27 ng NO-N/sq cm/hr during the wet season. A fertilized floodplain pasture exhibited higher fluxes, but an unfertilized upland pasture, which represents the fastest growing land use in the region, had flux rates similar to the forest sites. Wetting experiments at the end of the dry season caused large pulses of NO flux, equaling 10 percent to 20 percent of the estimated annual NO emissions of 0.5-1.0 kg N/ha from the forest sites. Absence of a forest canopy during the dry season and the first wet season rain probably results in substantial NO(x) export from the forest system that may be important to regional atmospheric chemical processes. Wetting experiments during the wet season and a natural rain event had little or no stimulatory effect on NO flux rates.

  13. Chemical Constituents with Free-Radical-Scavenging Activities from the Stem of Microcos paniculata

    Directory of Open Access Journals (Sweden)

    Yu Chen

    2010-08-01

    Full Text Available The free-radical-scavenging activities of various solvent extracts of Microcos paniculata were evaluated through in vitro model systems, such as 1,1-diphenyl-2-picrylhydrazyl (DPPH, 2,2'-azino-bis-(3-ethylbenzothiazoline-6-sulfonate (ABTS and Co (II EDTA-induced luminol chemiluminescence by flow injection. In all three of these systems the ethyl acetate (EtOAc extract showed the highest free-radical-scavenging activity compared with the other three (n-BuOH, water and petroleum ether extracts. Free-radical-scavenging assay-guided chromatographic separation of the EtOAc extract, using a normal-phase and reverse-phase silica gel column chromatography yielded five compounds: a new triterpene named methyl 3b-O-p-hydroxy-E-cinnamoyloxy-2a,23-dihydroxyolean-12-en-28-oate (1, whose spectral data are presented for the first time, together with four known compounds, epicatechin (2, 3-trans-feruloyl maslinic acid (3, maslinic acid (4 and sucrose (5. All of the compounds were isolated from Microcos paniculata for the first time. The compounds were identified by spectroscopic methods. Among them, compound 2 displayed significant free-radical-scavenging activity which is similar to that of standard antioxidant ascorbic acid (VC and therefore may be a promising natural antioxidant.

  14. Aluminum induces lipid peroxidation and aggregation of human blood platelets

    Directory of Open Access Journals (Sweden)

    T.J.C. Neiva

    1997-05-01

    Full Text Available Aluminum (Al3+ intoxication is thought to play a major role in the development of Alzheimer's disease and in certain pathologic manifestations arising from long-term hemodialysis. Although the metal does not present redox capacity, it can stimulate tissue lipid peroxidation in animal models. Furthermore, in vitro studies have revealed that the fluoroaluminate complex induces diacylglycerol formation, 43-kDa protein phosphorylation and aggregation. Based on these observations, we postulated that Al3+-induced blood platelet aggregation was mediated by lipid peroxidation. Using chemiluminescence (CL of luminol as an index of total lipid peroxidation capacity, we established a correlation between lipid peroxidation capacity and platelet aggregation. Al3+ (20-100 µM stimulated CL production by human blood platelets as well as their aggregation. Incubation of the platelets with the antioxidants nor-dihydroguaiaretic acid (NDGA (100 µM and n-propyl gallate (NPG (100 µM, inhibitors of the lipoxygenase pathway, completely prevented CL and platelet aggregation. Acetyl salicylic acid (ASA (100 µM, an inhibitor of the cyclooxygenase pathway, was a weaker inhibitor of both events. These findings suggest that Al3+ stimulates lipid peroxidation and the lipoxygenase pathway in human blood platelets thereby causing their aggregation

  15. Antioxidant effects of cultured wild ginseng root extracts on the male reproductive function of boars and guinea pigs.

    Science.gov (United States)

    Yun, Suk Jun; Bae, Gui-Seck; Park, Jae Hawn; Song, Tae Ho; Choi, Ahreum; Ryu, Buom-Yong; Pang, Myung-Geol; Kim, Eun Joong; Yoon, Minjung; Chang, Moon Baek

    2016-07-01

    The main objective of this study was to investigate the effects of cultured wild ginseng root extracts (cWGRE) on the sperm of boars and the reproductive system of guinea pigs. Firstly, semen collected from boars (n=10) were incubated in 38°C for 1h with xanthine and xanthine oxidase to generate ROS. The cWGRE was added to the sperm culture system to test its antioxidant effect on the boar sperm. The amount of Reactive Oxygen Species (ROS) was measured by a chemiluminescence assay using luminol. The results indicated that the addition of cWGRE to boar sperm culture inhibited xanthine and xanthine oxidase-induced ROS concentrations. Treatment with cWGRE also had a positive effect on maintaining sperm motility. Effects of cWGRE administration on vitamin C-deficient guinea pigs were further investigated. Hartley guinea pigs (n=25) at 8 weeks of age were randomly divided into five groups. With the exception of the positive control group, each group was fed vitamin C-deficient feed for 21days (d). Respective groups were also orally administered cWGRE, ginseng extract, or mixed ginsenosides for 21 days. In comparison to the control group, oral administration of cWGRE reduced (Pproduction. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Synthesis, electrochemistry, and electrogenerated chemiluminescence of two BODIPY-appended bipyridine homologues.

    Science.gov (United States)

    Qi, Honglan; Teesdale, Justin J; Pupillo, Rachel C; Rosenthal, Joel; Bard, Allen J

    2013-09-11

    Two new 2,2'-bipyridine (bpy) derivatives containing ancillary BODIPY chromophores attached at the 5- and 5'-positions (BB3) or 6- and 6'-positions (BB4) were prepared and characterized. In this work, the basic photophysics, electrochemistry, and electrogenerated chemiluminescence (ECL) of BB3 and BB4 are compared with those previously reported for a related bpy-BODIPY derivative (BB2) (J. Phys. Chem. C 2011, 115, 17993-18001). Cyclic voltammetry revealed that BB3 and BB4 display reversible 2e(-) oxidation and reduction waves, which consist of two closely spaced (50-70 mV) 1e(-) events. This redox behavior is consistent with the frontier molecular orbitals calculated for BB3 and BB4 and indicates that the 2,2'-bipyridine spacer of each bpy-BODIPY homologue does not facilitate efficient electronic communication between the tethered indacene units. In the presence of a coreactant such as tri-n-propylamine (TPA) or benzoyl peroxide (BPO), BB3 and BB4 exhibit strong ECL and produce spectra that are very similar to their corresponding photoluminescence profiles. The ECL signal obtained under annihilation conditions, however, is significantly different and is characterized by two distinct bands. One of these bands is centered at ∼570 nm and is attributed to emission via an S- or T-route. The second band occurs at longer wavelengths and is centered around ∼740 nm. The shape and concentration dependence of this long-wavelength ECL signal is not indicative of emission from an excimer or aggregate, but rather it suggests that a new emissive species is formed from the bpy-BODIPY luminophores during the annihilation process.

  17. Synthesis, Electrochemistry and Electrogenerated Chemiluminesce of two BODIPY-Appended Bipyridine Homologues

    Science.gov (United States)

    Qi, Honglan; Teesdale, Justin J.; Pupillo, Rachel C.

    2014-01-01

    Two new 2,2’-bipyridine (bpy) derivatives containing ancillary BODIPY chromophores attached at the 5- and 5’-positions (BB3) or 6- and 6’-positions (BB4) were prepared and characterized. In this work, the basic photophysics, electrochemistry and electrogenerated chemiluminescence (ECL) of BB3 and BB4 are compared with those previously reported for a related bpy-BODIPY derivative (BB2) (J. Phys. Chem. C 2011, 115, 17993–18001). Cyclic voltammetry revealed that BB3 and BB4 display reversible 2e− oxidation and reduction waves, which consist of two closely spaced (50 – 70 mV) 1e− events. This redox behavior is consistent with the frontier molecular orbitals calculated for BB3 and BB4 and indicates that the 2,2’-bipyridine spacer of each bpy- BODIPY homologue does not facilitate efficient electronic communication between the tethered indacene units. In the presence of a coreactant such as tri-n-propylamine (TPA) or benzoyl peroxide (BPO), BB3 and BB4 exhibit strong ECL and produce spectra that are very similar to their corresponding photoluminescence profiles. The ECL signal obtained under annihilation conditions, however, is significantly different and is characterized by two distinct bands. One of these bands is centered at ~570 nm and is attributed to emission via an S- or T-route. The second band, occurs at longer wavelengths and is centered around ~740 nm. The shape and concentration dependence of this long-wavelength ECL signal is not indicative of emission from an excimer or aggregate, but rather is suggests that a new emissive species is formed from the bpy-BODIPY luminophores during the annihilation process. PMID:23980850

  18. Application of a Chemiluminescence Detector for the Measurement of Total Oxides of Nitrogen and Ammonia in the Atmosphere

    Science.gov (United States)

    Hodgeson, J. A.; Bell, J. P.; Rehme, K. A.; Krost, K. J.; Stevens, R. K.

    1971-01-01

    By means of the thermal conversion of nitrogen dioxide to the nitric oxide, the chemiluminescent nitric oxide monitor, based on the nitric oxide plus ozone reaction, may be used for monitoring nitrogen dioxide plus nitric oxide (NO(x)). Under conditions previously described, ammonia is also converted to nitric oxide and therefore interferes. A metal surface, gold wool or stainless steel, operated at two different temperatures has been used to convert only nitrogen dioxide or nitrogen dioxide plus ammonia. Quantitative conversion of nitrogen dioxide to nitric oxide has been obtained at temperatures as low as 200 C. Conversion of ammonia is effected at temperatures of 300 C or higher. By the addition of a converter the basic nitric oxide monitor may be used for measuring NO(x) or NO(x) plus ammonia. As an alternate mode, for a fixed high temperature, a specific scrubber is described for removing NH3 without affecting NO2 concentrations.

  19. Decoupling peroxyacetyl nitrate from ozone in Chinese outflows observed at Gosan Climate Observatory

    Directory of Open Access Journals (Sweden)

    J. Han

    2017-09-01

    Full Text Available We measured peroxyacetyl nitrate (PAN and other reactive species such as O3, NO2, CO, and SO2 with aerosols including mass, organic carbon (OC, and elemental carbon (EC in PM2. 5 and K+ in PM1. 0 at Gosan Climate Observatory in Korea (33.17° N, 126.10° E during 19 October–6 November 2010. PAN was determined through fast gas chromatography with luminol chemiluminescence detection at 425 nm every 2 min. The PAN mixing ratios ranged from 0.1 (detection limit to 2.4 ppbv with a mean of 0.6 ppbv. For all measurements, PAN was unusually better correlated with PM2. 5 (Pearson correlation coefficient, γ =  0.79 than with O3 (γ =  0.67. In particular, the O3 level was highly elevated with SO2 at midnight, along with a typical midday peak when air was transported rapidly from the Beijing areas. The PAN enhancement was most noticeable during the occurrence of haze under stagnant conditions. In Chinese outflows slowly transported over the Yellow Sea, PAN gradually increased up to 2.4 ppbv at night, in excellent correlation with a concentration increase in PM2. 5 OC and EC, PM2. 5 mass, and PM1. 0 K+. The high K+ concentration and OC ∕ EC ratio indicated that the air mass was impacted by biomass combustion. This study highlights PAN decoupling with O3 in Chinese outflows and suggests PAN as a useful indicator for diagnosing continental outflows and assessing their perturbation of regional air quality in northeast Asia.

  20. Serum dosage of CPK-MB in dogs with ST deviation by chemiluminescence

    Directory of Open Access Journals (Sweden)

    André L.F. Santos

    2014-12-01

    Full Text Available Abstract: Although frequently in humans, hypoxic and ischemic heart diseases are poorly documented in dogs, with only few reports of acute myocardial infarction (AMI in this species. Some electrocardiographic findings might suggest myocardium hypoxia/ischemia, like ST segment elevation or depression, but there are no studies showing whether deviations in ST segment are associated to myocardial injury and serum increase of creatine phosphokinase (CPK-MB. In order to investigate possible myocardial cells injury in poor perfusion conditions, 38 dogs were studied, 20 with normal electrocardiogram and 18 with ST segment elevation or depression, recorded in lead II, at a paper speed of 50 mm/sec and N sensibility (1mV=1cm. Serum measurement of creatine phosphokinase isoenzyme MB (CPK-MB in normal dogs (group 1 determined control values (in ng/mL, which were compared to those obtained from dogs with deviation (group 2, which allowed confirmation or not of myocardial injury. CPK-MB mean values obtained from dogs in groups 1 and 2 were 0.540ng/ml (SD±0.890ng/mL and 0.440ng/mL (SD±1.106, respectively. At a significance level of 5%, the relation of CPK-MB with age, mass and total creatine phosphokinase (CPK-T was not significant in groups 1 and 2. CPK-MB showed no difference, at 5% level, between groups 1 and 2. In conclusion, it is possible to use the human chemiluminescent immunometric assay kit in canine species and that hypoxia/ischemia revealed by ST segment deviation does not mean significant myocardium injury.

  1. DNA tetrahedral scaffolds-based platform for the construction of electrochemiluminescence biosensor.

    Science.gov (United States)

    Feng, Qiu-Mei; Zhou, Zhen; Li, Mei-Xing; Zhao, Wei; Xu, Jing-Juan; Chen, Hong-Yuan

    2017-04-15

    Proximal metallic nanoparticles (NPs) could quench the electrochemiluminescence (ECL) emission of semiconductor quantum dots (QDs) due to Förster energy transfer (FRET), but at a certain distance, the coupling of light-emission with surface plasmon resonance (SPR) result in enhanced ECL. Thus, the modification strategies and distances control between QDs and metallic NPs are critical for the ECL intensity of QDs. In this strategy, a SPR enhanced ECL sensor based on DNA tetrahedral scaffolds modified platform was reported for the detection of telomerase activity. Due to the rigid three-dimensional structure, DNA tetrahedral scaffolds grafting on the electrode surface could accurately modulate the distance between CdS QDs and luminol labelled gold nanoparticles (L-Au NPs), meanwhile provide an enhanced spatial dimension and accessibility for the assembly of multiple L-Au NPs. The ECL intensities of both CdS QDs (-1.25V vs. SCE) and luminol (+0.33V vs. SCE) gradually increased along with the formation of multiple L-Au NPs at the vertex of DNA tetrahedral scaffolds induced by telomerase, bringing in a dual-potential ECL analysis. The proposed method showed high sensitivity for the identification of telomerase and was successfully applied for the differentiation of cancer cells from normal cells. This work suggests that DNA tetrahedral scaffolds could serve as an excellent choice for the construction of SPR-ECL system. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Solid-phase receptor-based assay for the detection of cyclic imines by chemiluminescence, fluorescence, or colorimetry.

    Science.gov (United States)

    Rodríguez, Laura P; Vilariño, Natalia; Molgó, Jordi; Aráoz, Rómulo; Antelo, Alvaro; Vieytes, Mercedes R; Botana, Luis M

    2011-08-01

    The spirolides and gymnodimines are marine phycotoxins included in the group of cyclic imines. The toxicity of these compounds to humans is still unknown, although their toxicity by intraperitoneal injection in rodents is very high. A receptor-based method was developed using the competition of the 13-desmethyl spirolide C with biotin-labeled α-bungarotoxin for binding to nicotinic acetylcholine receptors and the immobilization of the α-bungarotoxin-receptor complex on streptavidin-coated surfaces. The quantification of the immobilized receptor can be achieved using a specific antibody. Finally, after the addition of a secondary antibody labeled with horseradish peroxidase, three alternative substrates of this enzyme generate a chemiluminescent, fluorescent, or colorimetric signal. The assay performs well in shellfish extracts and the detection range is 5-150 nM of 13-desmethyl spirolide C in shellfish extracts, which is at least 5 times more sensitive than the existing fluorescence polarization assay. This assay can also detect gymnodimine, although with 10 times lower sensitivity than the spirolide. The detection of cyclic imines with microplate assays would be useful for screening purposes in order to reduce the number of samples to be processed by bioassays or analytical methods.

  3. Straightforward single-calibrant quantification of seized designer drugs by liquid chromatography-chemiluminescence nitrogen detection.

    Science.gov (United States)

    Rasanen, Ilpo; Kyber, Marianne; Szilvay, Ilmari; Rintatalo, Janne; Ojanperä, Ilkka

    2014-04-01

    Sixty-one different psychoactive substances were quantified by liquid chromatography-chemiluminescence nitrogen detection (LC-CLND) in 177 samples, using a single secondary standard (caffeine), in a trial concerning the quantitative purity assessment of drug-related material seized by the police in 2011-2012 and customs in 2011-2013 in Finland. The substances found were predominantly substituted phenethylamines, cathinones, tryptamines and synthetic cannabinoids, which were identified by appropriate methods prior to submitting the samples for quantification by LC-CLND. The equimolarity and expanded uncertainty of measurement by LC-CLND were on average 95% and 13%, respectively, based on 16 different substances. The median (mean) purity of stimulant/hallucinogenic drug samples seized at the border was 92.9% (87.6%) and in the street 82.0% (64.5%). The corresponding figures for powdery synthetic cannabinoid samples seized at the border and in the street were 99.0% (96.8%) and 90.0% (92.2%), respectively. There was generally only one active drug to be quantified in each sample. Seized herbal samples contained 0.15-9.2% of between one and three components. LC-CLND was found to be suitable for quantification of the nitrogen-containing drugs encountered in the study, showing sufficient N-equimolarity for both stimulant/hallucinogenic drugs and synthetic cannabinoids. The technique possesses great potential as a standard technique in forensic laboratories. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. A sensitive chemiluminescence enzyme immunoassay based on molecularly imprinted polymers solid-phase extraction of parathion.

    Science.gov (United States)

    Chen, Ge; Jin, Maojun; Du, Pengfei; Zhang, Chan; Cui, Xueyan; Zhang, Yudan; She, Yongxin; Shao, Hua; Jin, Fen; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2017-08-01

    The chemiluminescence enzyme immunoassay (CLEIA) method responds differently to various sample matrices because of the matrix effect. In this work, the CLEIA method was coupled with molecularly imprinted polymers (MIPs) synthesized by precipitation polymerization to study the matrix effect. The sample recoveries ranged from 72.62% to 121.89%, with a relative standard deviation (RSD) of 3.74-18.14%.The ratio of the sample matrix-matched standard curve slope rate to the solvent standard curve slope was 1.21, 1.12, 1.17, and 0.85 for apple, rice, orange and cabbage in samples pretreated with the mixture of PSA and C 18 . However, the ratio of sample (apple, rice, orange, and cabbage) matrix-matched standard-MIPs curve slope rate to the solvent standard curve was 1.05, 0.92, 1.09, and 1.05 in samples pretreated with MIPs, respectively. The results demonstrated that the matrices of the samples greatly interfered with the detection of parathion residues by CLEIA. The MIPs bound specifically to the parathion in the samples and eliminated the matrix interference effect. Therefore, the CLEIA method have successfully applied MIPs in sample pretreatment to eliminate matrix interference effects and provided a new sensitive assay for agro-products. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Comparison of enzyme-linked immunosorbent assay and rapid chemiluminescent analyser in the detection of myeloperoxidase and proteinase 3 autoantibodies.

    Science.gov (United States)

    Pucar, Phillippa A; Hawkins, Carolyn A; Randall, Katrina L; Li, Candice; McNaughton, Euan; Cook, Matthew C

    2017-06-01

    Antibodies to myeloperoxidase (MPO) and proteinase 3 (PR3) are vital in the diagnosis and management of ANCA-associated vasculitis. A chemiluminescent immunoassay (CLIA; Quanta Flash) provides MPO and PR3 antibody results in 30 minutes, which is much faster than enzyme-linked immunosorbent assay (ELISA). We compared the performance of ELISA (Orgentec) and CLIA (Quanta Flash) for MPO and PR3 antibody quantitation on 303 samples, comprising 196 consecutive samples received in a single diagnostic laboratory over a 3 month period, and 107 samples collected from 42 known vasculitis patients over a 40 month period. We observed a correlation between both methods using spearman correlation coefficients (MPO, r s  = 0.63, p assays) and disease relapse (correlation for both MPO and PR3 antibody quantitation r s  = 0.84, p = 0.03 and r s  = 0.78, p ELISA for measurement of MPO and PR3 antibodies. Copyright © 2017. Published by Elsevier B.V.

  6. Electrogenerated chemiluminescence of a cationic cyclometalated iridium complex–Nafion modified electrode in neutral aqueous solution

    International Nuclear Information System (INIS)

    Dong, YongPing; Ni, ZiYue; Zhang, Jing; Tong, BiHai; Chu, XiangFeng

    2013-01-01

    Electrogenerated chemiluminescence (ECL) of a cationic cyclometalated iridium complex, [(pqcm) 2 Ir(bpy)](PF 6 ) (1, pqcmH=2-phenyl-quinoline-4-carboxylic acid methyl ester, bpy=2,2′-bipyridine), was investigated at a bare glassy carbon electrode in CH 3 CN solution and 4 ECL peaks were observed. Then, the ECL of the iridium complex was studied in neutral phosphate buffer solution (PBS) by immobilizing it on a glassy carbon electrode. Two closely located ECL peaks were obtained at 1.07 and 1.40 V when the potential was scanned from −3.00 V to 2.20 V, while only one broad ECL peak located around −2.0 V was obtained when the potential was scanned from 2.20 V to −3.00 V. In the presence of oxalate, one ECL peak located around 1.22 V could be obtained except the broad ECL peak located at −2.00 V. The ECL peak at positive potential range was enhanced more than one magnitude in the presence of Nafion and was nearly 5-times higher than that of Ru(bpy) 3 2+ –Nafion modified electrode, suggesting that the synthesized iridium complex has great application potential in ECL detection. The ECL spectra of iridium complex were identical to its photoluminescence spectrum, indicating the same metal-to-ligand charge transfer (MLCT) excited states. The mechanisms of ECL were proposed based on the experimental results. The present ECL sensor gave a linear response for the oxalate concentration from 1.0×10 −6 to 1.0×10 −4 mol L −1 with a detection limit (S/N=3) of 9.1×10 −7 mol L −1 . -- Graphical abstract: Electrochemiluminescence (ECL) of immobilized novel cationic cyclometalated iridium complex in neutral phosphate buffer solution is reported for the first time. The intensity of iridium complex ECL is 5-times higher than that of Ru(bpy) 3 2+ ECL. Highlights: ► Cationic cyclometalated iridium complex was modified on a bare electrode. ► Electrochemiluminescence (ECL) of the modified electrode was studied. ► The ECL intensity is higher than that of Ru

  7. Determination of organic peroxides by liquid chromatography with on-line post-column ultraviolet irradiation and peroxyoxalate chemiluminescence detection.

    Science.gov (United States)

    Wada, Mitsuhiro; Inoue, Keiyu; Thara, Ayuko; Kishikawa, Naoya; Nakashima, Kenichiro; Kuroda, Naotaka

    2003-02-14

    A HPLC method was developed for the simultaneous determination of organic peroxides and hydrogen peroxide with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Organic peroxides [i.e., benzoyl peroxide (BP), tert.-butyl hydroperoxide (BHP), tert.-butyl perbenzoate (BPB), cumene hydroperoxide (CHP)] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide, which was determined by PO-CL detection. The conditions for UV irradiation and PO-CL detection were optimized by a flow injection analysis (FIA) system. Generation of hydrogen peroxide from peroxides with on-line UV irradiation also was confirmed by the FIA system by incorporating an enzyme column reactor immobilized with catalase. The separation of four organic peroxides and hydrogen peroxide by HPLC was accomplished isocratically on an ODS column within 30 min. The detection limits (signal-to-noise ratio=3) were 1.1 microM for hydrogen peroxide, 6.8 microM for BP, 31.3 microM for BHP, 7.5 microM for BPB and 1.3 microM for CHP. The proposed method was applied to the determination of BP in wheat flour.

  8. Determination of vitamin K homologues by high-performance liquid chromatography with on-line photoreactor and peroxyoxalate chemiluminescence detection

    International Nuclear Information System (INIS)

    Ahmed, Sameh; Kishikawa, Naoya; Nakashima, Kenichiro; Kuroda, Naotaka

    2007-01-01

    A sensitive and highly selective high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K homologues including phylloquinone (PK), menaquinone-4 (MK-4) and menaquinone-7 (MK-7) in human plasma using post-column peroxyoxalate chemiluminescence (PO-CL) detection following on-line ultraviolet (UV) irradiation. The method was based on ultraviolet irradiation (254 nm, 15 W) of vitamin K to produce hydrogen peroxide and a fluorescent product at the same time, which can be determined with PO-CL detection. The separation of vitamin K by HPLC was accomplished isocratically on an ODS column within 35 min. The method involves the use of 2-methyl-3-pentadecyl-1,4-naphthoquinone as an internal standard. The detection limits (signal-to-noise ratio = 3) were 32, 38 and 85 fmol for PK, MK-4 and MK-7, respectively. The recoveries of PK, MK-4 and MK-7 were greater than 82% and the inter- and intra-assay R.S.D. values were 1.9-5.4%. The sensitivity and selectivity of this method were sufficient for clinical and nutritional applications

  9. Effect of solvents on the enzyme mediated degradation of copolymers

    International Nuclear Information System (INIS)

    Banerjee, Aditi; Chatterjee, Kaushik; Madras, Giridhar

    2015-01-01

    The biodegradation of polycaprolactone (PCL), polylactic acid (PLA), polyglycolide (PGA) and their copolymers, poly (lactide-co-glycolide) and poly (D, L-lactide-co-caprolactone) (PLCL) was investigated. The influence of different solvents on the degradation of these polymers at 37 °C in the presence of two different lipases namely Novozym 435 and the free lipase of porcine pancreas was investigated. The rate coefficients for the polymer degradation and enzyme deactivation were determined using continuous distribution kinetics. Among the homopolymers, the degradation of PGA was nearly an order of magnitude lower than that for PCL and PLA. The overall rate coefficients of the copolymers were higher than their respective homopolymers. Thus, PLCL degraded faster than either PCL or PLA. The degradation was highly dependent on the viscosity of the solvent used with the highest degradation observed in acetone. The degradation of the polymers in acetone was nearly twice that observed in dimethyl sulfoxide indicating that the degradation decreases with increase in the solvent viscosity. The degradation of the polymers in water-solvent mixtures indicated an optimal water content of 2.5 wt% of water. (paper)

  10. Efficiency of a solid-phase chemiluminescence immunoassay for detection of antinuclear and cytoplasmic autoantibodies compared with gold standard immunoprecipitation.

    Science.gov (United States)

    Gelpí, Carmen; Pérez, Elena; Roldan, Cristina

    2014-09-01

    The aim of this study was to compare the degree of agreement of a novel Zenit RA chemiluminescent immunoassay (CLIA) from A. Menarini Diagnostics (Florence, Italy) and the gold standard immunoprecipitation assay to screen for the presence of specific anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his)tRNA-Synthetase) and anti-Scl-70(Topo I) antibodies. We studied 114 sera, 98 from patients with well-defined autoimmune connective tissue diseases and 16 from blood donor volunteers. All samples were fully characterized using the new chemiluminescent immunoassay and immunoprecipitation. In addition, all the samples were analyzed by indirect immunofluorescence (IIF) and anti-Scl-70(Topo I) antibodies were analyzed by immunoblot (IB) assay. Discrepant samples were analyzed using a commercial dot blot technique (Recomline from Mikrogen). The simple Kappa coefficient was used to measure the level of agreement between the results of Zenit RA CLIA and the gold standard. The Kappa agreement between Zenit RA CLIA and gold standard immunoprecipitation, as well as IB and IIFassays for the presence of anti-Scl-70(Topo I)(0.948) was excellent. The concordance between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-U1snRNP (0.883), anti-Ro/SS-A (0.878), anti-Jo-1((his)tRNA-Synthetase) (0.791) and anti-Sm (0.786) was good, and excellent when the cut-off was raised to 14 U/ml (arbitrary units/ml). Between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-La/SS-B, the Kappa agreement had a value of 0.689, but this improved to 0.775 when the cut-off was raised to14 U/ml. Precision was good based on the evaluation of replicate samples. Inter-assay coefficient variation was lower than 3.4 % (CV in %) in all the kits and <1.2 % (CV in  %) for intra-assay measurements. Our findings show that Zenit RA CLIA was specific and sensitive to detect anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his

  11. Sol-gel-immobilized Tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor for high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Choi, Han Nim; Cho, Sung-Hee; Park, Yu-Jin; Lee, Dai Woon; Lee, Won-Yong

    2005-01-01

    The sol-gel-immobilized Tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy) 3 2+ ] electrogenerated chemiluminescence (ECL) sensor was applied to the reversed-phase high-performance liquid chromatography (HPLC) determination of phenothiazine derivatives (promazine, chlorpromazine, triflupromazine, thioridazine, and trifluoperazine) and erythromycin in human urine samples. In this method, Ru(bpy) 3 2+ was immobilized in sol-gel-derived titania (TiO 2 )-Nafion nanocomposite films coated on a dual platinum electrode. This method eliminates an extra pump needed for the delivery of Ru(bpy) 3 2+ reagent into a reaction/observation zone in front of photomultiplier tube because the immobilized-Ru(bpy) 3 2+ is recycled on the electrode surface by an applied potential at +1.3 V versus Ag/AgCl (3 M NaCl) reference electrode. The resulting analytical performances such as detection limit, working range, sensitivity, and measurement precision were slightly worse than those obtained with the conventional post-column Ru(bpy) 3 2+ addition approach. The lack of significant interferences and the low detection limits for phenothiazine derivatives and erythromycin indicate that the proposed HPLC-Ru(bpy) 3 2+ ECL detection method is suitable for the determination of those compounds in biological fluids

  12. [Fundamental evaluation of apolipoprotein B-48 by chemiluminescence enzyme immunoassay--identification of apolipoprotein B-48 with immunoblotting].

    Science.gov (United States)

    Sato, Itsuko; Fujioka, Yoshio; Hayashi, Fujio; Mukai, Masahiko; Kawano, Seiji; Ishikawa, Yuichi; Yamashita, Shizuya; Kumagai, Shunichi

    2007-06-01

    Apolipoprotein B-48 (apo B-48) is a constituent of chylomicrons and chylomicron remnants, and its fasting concentration has been reported to be a marker of postprandial hyperlipidemia, which is thought to be a risk factor of atherosclerosis. We evaluated the serum apo B-48 concentrations by chemiluminescence enzyme immunoassay (CLEIA), which was recently introduced as Lumipulse f fully automated immunosaasy analyzer by Fujirebio Inc (Tokyo, Japan), and performed immunoblotting on agarose gel electrophoresis with anti-apo B-48 antibody. Apo B-48 assay was intra-assay reproducible (CVs: 1.9-3.1%) and inter-assay reproducible (CVs: 2.2-4.4%). The assay range for apo B-48 was from 0.2 to 40.0 microg/ml. The effects of interfering substances such as free/conjugated birirubin, hemoglobin, Intrafat, ascorbic acid and rheumatoid factor were negligible. For storage, it was preferable to freeze, and to avoid frozen-thaw process as much as possible. Anti-apo B-48 antibody was reactive over a wide range from origin to the position of very-low-density lipoproteins in immunoblotting after agarose gel electrophoresis. Apo B-48 measurement by CLEIA was feasible to clinical use for the assessment of lipoprotein metabolism.

  13. Flow injection determination of diclofenac sodium based on its sensitizing effect on the chemiluminescent reaction of acidic potassium permanganate-formaldehyde.

    Science.gov (United States)

    Song, Jingjing; Sun, Pulv; Ji, Zhongling; Li, Jianguo

    2015-02-01

    A sensitive and simple chemiluminescent (CL) method for the determination of diclofenac sodium has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between formaldehyde and acidic potassium permanganate. A calibration curve is constructed for diclofenac sodium under optimized experimental parameters over the range 0.040-5.0 µg/mL and the limit of detection is 0.020 µg/mL (3σ). The inter-assay relative standard deviation for 0.040 µg/mL diclofenac sodium (n = 11) is 2.0%. This method is rapid, sensitive, simple, and shows good selectivity and reproducibility. The proposed method has been successfully applied to the determination of the studied diclofenac sodium in pharmaceutical preparations with satisfactory results. Furthermore, the possible mechanism for the CL reaction has been discussed in detail on the basis of UV and CL spectra. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Development of a PCR/LDR/flow-through hybridization assay using a capillary tube, probe DNA-immobilized magnetic beads and chemiluminescence detection.

    Science.gov (United States)

    Hommatsu, Manami; Okahashi, Hisamitsu; Ohta, Keisuke; Tamai, Yusuke; Tsukagoshi, Kazuhiko; Hashimoto, Masahiko

    2013-01-01

    A polymerase chain reaction (PCR)/ligase detection reaction (LDR)/flow-through hybridization assay using chemiluminescence (CL) detection was developed for analyzing point mutations in gene fragments with high diagnostic value for colorectal cancers. A flow-through hybridization format using a capillary tube, in which probe DNA-immobilized magnetic beads were packed, provided accelerated hybridization kinetics of target DNA (i.e. LDR product) to the probe DNA. Simple fluid manipulations enabled both allele-specific hybridization and the removal of non-specifically bound DNA in the wash step. Furthermore, the use of CL detection greatly simplified the detection scheme, since CL does not require a light source for excitation of the fluorescent dye tags on the LDR products. Preliminary results demonstrated that this analytical system could detect both homozygous and heterozygous mutations, without the expensive instrumentation and cumbersome procedures required by conventional DNA microarray-based methods.

  15. Electrogenerated chemiluminescence: An oxidative-reductive mechanism between quinolone antibiotics and tris(2,2'-bipyridyl)ruthenium(II)

    International Nuclear Information System (INIS)

    Burkhead, Matthew S.; Wang, Heeyoung; Fallet, Marcel; Gross, Erin M.

    2008-01-01

    The cyclic voltammetry and electrogenerated chemiluminescent (ECL) reactions of a series of quinolone and fluoroquinolone antibiotics were investigated in a flow injection analysis (FIA) system. 7-Piperazinyl fluoroquinolone antibiotics were found to participate as a coreactant in an oxidative-reductive ECL mechanism with tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy) 3 2+ ) as the luminescent reagent. The reaction mechanism was investigated in order to understand and optimize the processes leading to light emission. The optimal conditions included a solution pH ∼7 at a flow rate of 3.0 mL min -1 with no added organic modifier and application of 1.2 V vs. a Pt quasi-reference electrode (QRE). Fluoroquinolones containing a tertiary distal nitrogen on the piperazine ring, such as enrofloxacin and ofloxacin, reacted to produce more intense ECL than those with a secondary nitrogen, such as ciprofloxacin and norfloxacin. The method linear range, precision, detection limits, and sensitivity for the detection of enrofloxacin and ciprofloxacin were compared to that of tripropylamine. The method was applied to the determination of the ciprofloxacin content in a pharmaceutical preparation. The assay is discussed in terms of its analytical figures of merit, ease of use, speed, accuracy and application to pharmaceutical samples

  16. Simultaneous determination of amiodarone and its metabolite desethylamiodarone by high-performance liquid chromatography with chemiluminescent detection

    International Nuclear Information System (INIS)

    Perez-Ruiz, Tomas; Martinez-Lozano, Carmen; Garcia-Martinez, Maria Dolores

    2008-01-01

    A novel method was developed for the determination of amiodarone and desethylamiodarone by high-performance liquid chromatography (HPLC) coupled with chemiluminescent (CL) detection. The procedure is based on the post-column photolysis of the analytes into photoproducts which are active in the tris(2,2'-bipyridyl)ruthenium(III) [Ru(bpy) 3 3+ ] CL system. Ru(bpy) 3 3+ was on-line generated by photo-oxidation of the Ru(II) complex in the presence of peroxydisulfate. The separation was carried out on a Mediterranea C 18 column with isocratic elution using a mixture of methanol and 0.017 mol L -1 ammonium sulfate buffer of pH 6.8. Under the optimum conditions, analytical curves, based on standard solutions, were linear over the range 0.1-50 μg mL -1 for amiodarone and 0.5-25 μg mL -1 for desethylamiodarone. The detection limits of amiodarone and desethylamiodarone were 0.02 and 0.11 μg mL -1 , respectively. Intra- and inter-day precision values of 0.9% relative standard deviation (R.S.D.) (n = 10) and 1.6% R.S.D. (n = 15), respectively, were obtained. The method was applied successfully to the determination of these compounds in serum and pharmaceutical formulations

  17. Evaluation of a magnetic particles-based chemiluminescence enzyme immunoassay for Golgi protein 73 in human serum.

    Science.gov (United States)

    Liu, Xiangyi; Wan, Xiaohua; Lu, Sheng; Zhang, Lijun; Yu, Shaohua; Lu, Xinxin

    2015-05-20

    Golgi protein 73 (GP73) is regarded as a potential serum biomarker for early diagnosis of hepatocellular carcinoma (HCC). We developed a rapid magnetic particles-based chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of serum GP73. Fluorescein isothiocyanate (FITC) and alkaline phosphatase (ALP) were used to label 2 different monoclonal antibodies to GP73. Serum GP73 was captured with labeled antibodies and formed a sandwiched immunoreaction. The magnetic particles (MPs) coated with anti-FITC antibody were used as a means of separation of the GP73 protein from other serum proteins. After adding the enzyme substrate solution, the relative light unit (RLU) was measured. A MPs-CLEIA for serum GP73 was established and evaluated. The RLU was directly proportional to the concentration of GP73. The method linearity was 5-600 μg/l. Limit of the blank was 2.19 μg/l. The intra- and inter-assay imprecision was 73-0.89), and the sensitivity and specificity, with cut-off value of 115.6 μg/l, were 75.4% and 92.1%, respectively. The proposed method demonstrates an acceptable performance for quantifying serum GP73. This assay could be appropriate for routine use in clinical laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. A new approach for bisphenol A detection employing fluorosurfactant-capped gold nanoparticle-amplified chemiluminescence from cobalt(II) and peroxymonocarbonate.

    Science.gov (United States)

    Pan, Feng; Liu, Lin; Dong, Shichao; Lu, Chao

    2014-07-15

    In this work, we utilized the nonionic fluorosurfactant-capped gold nanoparticles (GNPs) as a novel chemiluminescence (CL) probe for the determination of trace bisphenol A. Bisphenol A can induce a sharp decrease in CL intensity from the GNP-Co(2+)-peroxymonocarbonate (HCO4(-)) system. Under the selected experimental conditions, a linear relationship was obtained between the CL intensity and the logarithm of concentration of bisphenol A in the range of 0.05-50 μM (R(2) = 0.9936), and the detection limit at a signal-to-noise ratio of 3 for bisphenol A was 10 nM. The applicability of the proposed method has been validated by determining bisphenol A in real polycarbonate samples with satisfactory results. The recoveries for bisphenol A in spiked samples were found to be between 94.4% and 105.0%. The relative standard deviation (RSD) for 12 repeated measurements of 0.5 μM bisphenol A was 2.2%. The proposed method described herein was simple, selective and obviated the need of extensive sample pretreatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Antifatigue and Antioxidant Activity of Alcoholic Extract from Saussurea involucrata

    Directory of Open Access Journals (Sweden)

    Jang-Chang Lee

    2011-10-01

    Full Text Available Fatigue is a noticeable and highly prevalent symptom in tense, industriously, and economically affluent modern society. Therefore, new antifatigue agents to smooth the fatigue feature are an energetic topic. The total ethanol extract (ESI of Saussurea involucrata Kar et Kir., known as Tian-Shan snow lotus, was evaluated for antifatigue activity in ICR mice with mice forced swimming test and the determination of the contents of blood lactic acid and serum urea nitrogen. ESI (0.05, 0.15, 0.25 g/kg was administered orally to mice for 4 weeks. The average swimming times to exhaustion of the ESI-treated ICR mice (0.15, 0.25 g/kg were prolonged by 132% and 180% (p<0.001 with a lessening of fatigue compared with that of the control group. Analysis of biochemical parameters showed that levels of serum urea nitrogen and blood lactic acid of experimental groups were also decreased significantly (p<0.001 compared with that of the control group. The antioxidant activity of ESI was investigated by the 2,2-diphenyl-1-picrylhydrazyl (DPPH free radical-scavenging assay and the hydrogen peroxide-induced luminol chemiluminescence assay and the results indicated that ESI exerts DPPH scavenging ability and reducing power. These results provide scientific evidence that S. involucrata may have been potential as an antifatigue agent.

  20. A Highly Sensitive Chemiluminometric Assay for Real-Time Detection of Biological Hydrogen Peroxide Formation.

    Science.gov (United States)

    Zhu, Hong; Jia, Zhenquan; Trush, Michael A; Li, Y Robert

    2016-05-01

    Hydrogen peroxide (H 2 O 2 ) is a major reactive oxygen species (ROS) produced by various cellular sources, especially mitochondria. At high levels, H 2 O 2 causes oxidative stress, leading to cell injury, whereas at low concentrations, this ROS acts as an important second messenger to participate in cellular redox signaling. Detection and measurement of the levels or rates of production of cellular H 2 O 2 are instrumental in studying the biological effects of this major ROS. While a number of assays have been developed over the past decades for detecting and/or quantifying biological H 2 O 2 formation, none has been shown to be perfect. Perhaps there is no perfect assay for sensitively and accurately quantifying H 2 O 2 as well as other ROS in cells, wherein numerous potential reactants are present to interfere with the reliable measurement of the specific ROS. In this context, each assay has its own advantages and intrinsic limitations. This article describes a highly sensitive assay for real-time detection of H 2 O 2 formation in cultured cells and isolated mitochondria. This assay is based on the luminol/horseradish peroxidase-dependent chemiluminescence that is inhibitable by catalase. The article discusses the usefulness and shortcomings of this chemiluminometric assay in detecting biological H 2 O 2 formation induced by beta-lapachone redox cycling with both cells and isolated mitochondria.

  1. An aptasensor for staphylococcus aureus based on nicking enzyme amplification reaction and rolling circle amplification.

    Science.gov (United States)

    Xu, Jingguo; Guo, Jia; Maina, Sarah Wanjiku; Yang, Yumeng; Hu, Yimin; Li, Xuanxuan; Qiu, Jiarong; Xin, Zhihong

    2018-05-15

    An ultra-sensitive aptamer-based biosensor for the detection of staphylococcus aureus was established by adopting the nicking enzyme amplification reaction (NEAR) and the rolling circle amplification (RCA) technologies. Aptamer-probe (AP), containing an aptamer and a probe sequence, was developed to act as the recognition unit of the biosensor, which was specifically bound to S. aureus. The probe was released from AP and initiated into the subsequent DNA amplification reactions where S. aureus was present, converting the detection of S. aureus to the investigation of probe oligonucleotide. The RCA amplification products contained a G-quadruplex motif and formed a three dimensional structure in presence of hemin. The G4/hemin complex showed horseradish peroxidase (HRP)-mimic activity and catalyzed the chemiluminescence reaction of luminol mediated by H 2 O 2 . The results showed that the established biosensor could detect S. aureus specifically with a good linear correlation at 5-10 4  CFU/mL. The signal values based on NEAR-RCA two-step cycle were boosted acutely, much higher than that relied on one-cycle magnification. The limit of detection (LoD) was determined to be as low as 5 CFU/mL. The established aptasensor exhibited a good discrimination of living against dead S. aureus, and can be applied to detect S. aureus in the food industry. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Auroral nitric oxide concentration and infrared emission

    Science.gov (United States)

    Reidy, W. P.; Degges, T. C.; Hurd, A. G.; Stair, A. T., Jr.; Ulwick, J. C.

    1982-05-01

    Rocket-borne measurements of infrared auroral emission by nitric oxide are analyzed. Four rocket flights provided opportunities to measure 5.3- and 2.7-micron NO emission by means of infrared fixed band radiometers and CVF spectrometers, narrow band photometers, and incident energy spectra on various occasions. Analysis of infrared emission profiles and electron flux data indicates the NO density to be significantly enhanced with respect to midlatitude values. NO emission in the fundamental 5.3-micron band is attributed to resonance excitation by warm earth radiation, collisional excitation primarily by O atoms and chemiluminescence from the reaction of N with O2; with an energy efficiency of 0.015. The overtone band emission at 2.7 microns is accounted for by chemiluminescence produced with an energy efficiency of 0.0054. Total photon yield for the chemiluminescence reaction is estimated to range from 1.2 to 2.4 vibrational quanta per NO molecule.

  3. Cyclic mechanical stretch enhances BMP9-induced osteogenic differentiation of mesenchymal stem cells.

    Science.gov (United States)

    Song, Yang; Tang, Yinhong; Song, Jinlin; Lei, Mingxing; Liang, Panpan; Fu, Tiwei; Su, Xudong; Zhou, Pengfei; Yang, Li; Huang, Enyi

    2018-04-01

    The purpose of this study was to investigate whether mechanical stretch can enhance the bone morphogenetic protein 9 (BMP9)-induced osteogenic differentiation in MSCs. Recombinant adenoviruses were used to overexpress the BMP9 in C3H10T1/2 MSCs. Cells were seeded onto six-well BioFlex collagen I-coated plates and subjected to cyclic mechanical stretch [6% elongation at 60 cycles/minute (1 Hz)] in a Flexercell FX-4000 strain unit for up to 12 hours. Immunostaining and confocal microscope were used to detect cytoskeleton organization. Cell cycle progression was checked by flow cytometry. Alkaline phosphatase activity was measured with a Chemiluminescence Assay Kit and was quantified with a histochemical staining assay. Matrix mineralization was examined by Alizarin Red S Staining. Mechanical stretch induces cytoskeleton reorganization and inhibits cell proliferation by preventing cells entry into S phase of the cell cycle. Although mechanical stretch alone does not induce the osteogenic differentiation of C3H10T1/2 MSCs, co-stimulation with mechanical stretch and BMP9 enhances alkaline phosphatase activity. The expression of key lineage-specific regulators (e.g., osteocalcin (OCN), SRY-related HMG-box 9, and runt-related transcription factor 2) is also increased after the co-stimulation, compared to the mechanical stretch stimulation along. Furthermore, mechanical stretch augments the BMP9-mediated bone matrix mineralization of C3H10T1/2 MSCs. Our results suggest that mechanical stretch enhances BMP9-induced osteoblastic lineage specification in C3H10T1/2 MSCs.

  4. Calibration and LOD/LOQ estimation of a chemiluminescent hybridization assay for residual DNA in recombinant protein drugs expressed in E. coli using a four-parameter logistic model.

    Science.gov (United States)

    Lee, K R; Dipaolo, B; Ji, X

    2000-06-01

    Calibration is the process of fitting a model based on reference data points (x, y), then using the model to estimate an unknown x based on a new measured response, y. In DNA assay, x is the concentration, and y is the measured signal volume. A four-parameter logistic model was used frequently for calibration of immunoassay when the response is optical density for enzyme-linked immunosorbent assay (ELISA) or adjusted radioactivity count for radioimmunoassay (RIA). Here, it is shown that the same model or a linearized version of the curve are equally useful for the calibration of a chemiluminescent hybridization assay for residual DNA in recombinant protein drugs and calculation of performance measures of the assay.

  5. Electrogenerated chemiluminescence detection for deoxyribonucleic acid hybridization based on gold nanoparticles carrying multiple probes

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Chengxiao; Li Yan; Qi Honglan

    2006-01-01

    A novel sensitive electrogenerated chemiluminescence (ECL) method for the detection deoxyribonucleic acid (DNA) hybridization based on gold nanoparticles carrying multiple probes was developed. Ruthenium bis(2,2'-bipyridine)(2,2'-bipyridine-4,4'-dicarboxylic acid)-N-hydroxysuccinimide ester (Ru(bpy) 2 (dcbpy)NHS) was used as a ECL label and gold nanoparticle as a carrier. Probe single strand DNA (ss-DNA) was self-assembled at the 3'-terminal with a thiol group to the surface of gold nanoparticle and covalently labeled at the 5'-terminal of a phosphate group with Ru(bpy) 2 (dcbpy)NHS and the resulting conjugate (Ru(bpy) 2 (dcbpy)NHS)-ss-DNA-Au, was taken as a ECL probe. When target analyte ss-DNA was immobilized on a gold electrode by self-assembled monolayer technique and then hybridized with the ECL probe to form a double-stranded DNA (ds-DNA), a strong ECL response was electrochemically generated. The ECL intensity was linearly related to the concentration of the complementary sequence (target ss-DNA) in the range from 1.0 x 10 -11 to 1.0 x 10 -8 mol L -1 , and the linear regression equation was S = 57301 + 4579.6 lg C (unit of C is mol L -1 ). A detection limit of 5.0 x 10 -12 mol L -1 for target ss-DNA was achieved. The ECL signal generated from many reporters of ECL probe prepared is greatly amplified, compared to the convention scheme which is based on one reporter per hybridization event

  6. A novel "dual-potential" electrochemiluminescence aptasensor array using CdS quantum dots and luminol-gold nanoparticles as labels for simultaneous detection of malachite green and chloramphenicol.

    Science.gov (United States)

    Feng, Xiaobin; Gan, Ning; Zhang, Huairong; Yan, Qing; Li, Tianhua; Cao, Yuting; Hu, Futao; Yu, Hongwei; Jiang, Qianli

    2015-12-15

    A novel type of "dual-potential" electrochemiluminescence (ECL) aptasensor array was fabricated on a homemade screen-printed carbon electrode (SPCE) for simultaneous detection of malachite green (MG) and chloramphenicol (CAP) in one single assay. The SPCE substrate consisted of a common Ag/AgCl reference electrode, carbon counter electrode and two carbon working electrodes (WE1 and WE2). In the system, CdS quantum dots (QDs) were modified on WE1 as cathode ECL emitters and luminol-gold nanoparticles (L-Au NPs) were modified on WE2 as anode ECL emitters. Then the MG aptamer complementary strand (MG cDNA) and CAP aptamer complementary strand (CAP cDNA) were attached on CdS QDs and L-Au NPs, respectively. The cDNA would hybridize with corresponding aptamer that was respectively tagged with cyanine dye (Cy5) (as quenchers of CdS QDs) and chlorogenic acid (CA) (as quenchers of l-Au NPs) using poly(ethylenimine) (PEI) as a bridging agent. PEI could lead to a large number of quenchers on the aptamer, which increased the quenching efficiency. Upon MG and CAP adding, the targets could induce strand release due to the highly affinity of analytes toward aptamers. Meanwhile, it could release the Cy5 and CA, which recovered cathode ECL of CdS QDs and anode ECL of L-Au NPs simultaneously. This "dual-potential" ECL strategy could be used to detect MG and CAP with the linear ranges of 0.1-100 nM and 0.2-150 nM, with detection limits of 0.03 nM and 0.07 nM (at 3sB), respectively. More importantly, this designed method was successfully applied to determine MG and CAP in real fish samples and held great potential in the food analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Development of a wireless, self-sustaining damage detection sensor system based on chemiluminescence for structural health monitoring

    Science.gov (United States)

    Kuang, K. S. C.

    2014-03-01

    A novel application of chemiluminescence resulting from the chemical reaction in a glow-stick as sensors for structural health monitoring is demonstrated here. By detecting the presence of light emitting from these glow-sticks, it is possible to develop a low-cost sensing device with the potential to provide early warning of damage in a variety of engineering applications such as monitoring of cracks or damage in concrete shear walls, detecting of ground settlement, soil liquefaction, slope instability, liquefaction-related damage of underground structure and others. In addition, this paper demonstrates the ease of incorporating wireless capability to the sensor device and the possibility of making the sensor system self-sustaining by means of a renewable power source for the wireless module. A significant advantage of the system compared to previous work on the use of plastic optical fibre (POF) for damage detection is that here the system does not require an electrically-powered light source. Here, the sensing device, embedded in a cement host, is shown to be capable of detecting damage. A series of specimens with embedded glow-sticks have been investigated and an assessment of their damage detection capability will be reported. The specimens were loaded under flexure and the sensor responses were transmitted via a wireless connection.

  8. Electrogenerated chemiluminescence: An oxidative-reductive mechanism between quinolone antibiotics and tris(2,2'-bipyridyl)ruthenium(II)

    Energy Technology Data Exchange (ETDEWEB)

    Burkhead, Matthew S.; Wang, Heeyoung; Fallet, Marcel [Department of Chemistry, Creighton University, Omaha, NE 68178 (United States); Gross, Erin M. [Department of Chemistry, Creighton University, Omaha, NE 68178 (United States)], E-mail: eringross@creighton.edu

    2008-04-21

    The cyclic voltammetry and electrogenerated chemiluminescent (ECL) reactions of a series of quinolone and fluoroquinolone antibiotics were investigated in a flow injection analysis (FIA) system. 7-Piperazinyl fluoroquinolone antibiotics were found to participate as a coreactant in an oxidative-reductive ECL mechanism with tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy){sub 3}{sup 2+}) as the luminescent reagent. The reaction mechanism was investigated in order to understand and optimize the processes leading to light emission. The optimal conditions included a solution pH {approx}7 at a flow rate of 3.0 mL min{sup -1} with no added organic modifier and application of 1.2 V vs. a Pt quasi-reference electrode (QRE). Fluoroquinolones containing a tertiary distal nitrogen on the piperazine ring, such as enrofloxacin and ofloxacin, reacted to produce more intense ECL than those with a secondary nitrogen, such as ciprofloxacin and norfloxacin. The method linear range, precision, detection limits, and sensitivity for the detection of enrofloxacin and ciprofloxacin were compared to that of tripropylamine. The method was applied to the determination of the ciprofloxacin content in a pharmaceutical preparation. The assay is discussed in terms of its analytical figures of merit, ease of use, speed, accuracy and application to pharmaceutical samples.

  9. Study on the interaction of catalase with pesticides by flow injection chemiluminescence and molecular docking.

    Science.gov (United States)

    Tan, Xijuan; Wang, Zhuming; Chen, Donghua; Luo, Kai; Xiong, Xunyu; Song, Zhenghua

    2014-08-01

    The interaction mechanisms of catalase (CAT) with pesticides (including organophosphates: disulfoton, isofenphos-methyl, malathion, isocarbophos, dimethoate, dipterex, methamidophos and acephate; carbamates: carbaryl and methomyl; pyrethroids: fenvalerate and deltamethrin) were first investigated by flow injection (FI) chemiluminescence (CL) analysis and molecular docking. By homemade FI-CL model of lg[(I0-I)/I]=lgK+nlg[D], it was found that the binding processes of pesticides to CAT were spontaneous with the apparent binding constants K of 10(3)-10(5) L mol(-1) and the numbers of binding sites about 1.0. The binding abilities of pesticides to CAT followed the order: fenvalerate>deltamethrin>disulfoton>isofenphos-methyl>carbaryl>malathion>isocarbophos>dimethoate>dipterex>acephate>methomyl>methamidophos, which was generally similar to the order of determination sensitivity of pesticides. The thermodynamic parameters revealed that CAT bound with hydrophobic pesticides by hydrophobic interaction force, and with hydrophilic pesticides by hydrogen bond and van der Waals force. The pesticides to CAT molecular docking study showed that pesticides could enter into the cavity locating among the four subdomains of CAT, giving the specific amino acid residues and hydrogen bonds involved in CAT-pesticides interaction. It was also found that the lgK values of pesticides to CAT increased regularly with increasing lgP, Mr, MR and MV, suggesting that the hydrophobicity and steric property of pesticide played essential roles in its binding to CAT. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Dog cloning with in vivo matured oocytes obtained using electric chemiluminescence immunoassay-predicted ovulation method.

    Science.gov (United States)

    Lee, Seunghoon; Zhao, Minghui; No, Jingu; Nam, Yoonseok; Im, Gi-Sun; Hur, Tai-Young

    2017-01-01

    Radioactive immunoassay (RIA) is a traditional serum hormone assay method, but the application of the method in reproductive studies is limited by the associated radioactivity. The aim of present study was to evaluate the reliability of RIA and to compare its canine serum progesterone concentration determination accuracy to that of the electric chemiluminescence immunoassay (ECLI). In vivo matured oocytes were utilized for canine somatic cell nuclear transfer (SCNT), and serum progesterone levels were assessed to accurately determine ovulation and oocyte maturation. Canine serum progesterone concentrations during both proestrus and estrus were analyzed by RIA and ECLI to determine the ovulation day. Although both methods detected similar progesterone levels before ovulation, the mean progesterone concentration determined using ECLI was significantly higher than of RIA three days before ovulation. Following ovulation, oocytes were collected by surgery, and a lower percentage of mature oocytes were observed using ECLI (39%) as compared to RIA (67%) if 4-8ng/ml of progesterone were used for determination of ovulation. A high percentage of mature oocytes was observed using ECLI when 6-15 ng/mL of progesterone was used for ovulation determination. To determine whether ECLI could be used for canine cloning, six canines were selected as oocyte donors, and two puppies were obtained after SCNT and embryo transfer. In conclusion, compared to the traditional RIA method, the ECLI method is a safe and reliable method for canine cloning.

  11. Ultra-sensitive chemiluminescence imaging DNA hybridization method in the detection of mosquito-borne viruses and parasites.

    Science.gov (United States)

    Zhang, Yingjie; Liu, Qiqi; Zhou, Biao; Wang, Xiaobo; Chen, Suhong; Wang, Shengqi

    2017-01-25

    Mosquito-borne viruses (MBVs) and parasites (MBPs) are transmitted through hematophagous arthropods-mosquitoes to homoiothermous vertebrates. This study aims at developing a detection method to monitor the spread of mosquito-borne diseases to new areas and diagnose the infections caused by MBVs and MBPs. In this assay, an ultra-sensitive chemiluminescence (CL) detection method was developed and used to simultaneously detect 19 common MBVs and MBPs. In vitro transcript RNA, virus-like particles (VLPs), and plasmids were established as positive or limit of detection (LOD) reference materials. MBVs and MBPs could be genotyped with high sensitivity and specificity. The cut-off values of probes were calculated. The absolute LODs of this strategy to detect serially diluted in vitro transcribed RNAs of MBVs and serially diluted plasmids of MBPs were 10 2 -10 3 copies/μl and 10 1 -10 2 copies/μl, respectively. Further, the LOD of detecting a strain of pre-quantified JEV was 10 1.8 -10 0.8 PFU/ml, fitted well in a linear regression model (coefficient of determination = 0.9678). Ultra-sensitive CL imaging DNA hybridization was developed and could simultaneously detect various MBVs and MBPs. The method described here has the potential to provide considerable labor savings due to its ability to screen for 19 mosquito-borne pathogens simultaneously.

  12. Chemiluminescence analyzer of NOx as a high-throughput screening tool in selective catalytic reduction of NO

    International Nuclear Information System (INIS)

    Oh, Kwang Seok; Woo, Seong Ihl

    2011-01-01

    A chemiluminescence-based analyzer of NO x gas species has been applied for high-throughput screening of a library of catalytic materials. The applicability of the commercial NO x analyzer as a rapid screening tool was evaluated using selective catalytic reduction of NO gas. A library of 60 binary alloys composed of Pt and Co, Zr, La, Ce, Fe or W on Al 2 O 3 substrate was tested for the efficiency of NO x removal using a home-built 64-channel parallel and sequential tubular reactor. The NO x concentrations measured by the NO x analyzer agreed well with the results obtained using micro gas chromatography for a reference catalyst consisting of 1 wt% Pt on γ-Al 2 O 3 . Most alloys showed high efficiency at 275 °C, which is typical of Pt-based catalysts for selective catalytic reduction of NO. The screening with NO x analyzer allowed to select Pt-Ce (X) (X=1–3) and Pt–Fe (2) as the optimal catalysts for NO x removal: 73% NO x conversion was achieved with the Pt–Fe (2) alloy, which was much better than the results for the reference catalyst and the other library alloys. This study demonstrates a sequential high-throughput method of practical evaluation of catalysts for the selective reduction of NO.

  13. Modulation of neutrophil and monocyte function by recombinant human granulocyte macrophage colony-stimulating factor in patients with lymphoma

    DEFF Research Database (Denmark)

    Kharazmi, A; Nielsen, H; Hovgaard, D

    1991-01-01

    by up to 43-fold. rhGM-CSF treatment did not affect degranulation of the neutrophils as measured by release of vitamin B12 binding protein. Degree of modulation of neutrophil and monocyte function by rhGM-CSF was independent of rhGM-CSF dosages administered. These data suggest that phagocytic defence...... and chemiluminescence responses to f-Met-Leu-Phe, zymosan activated serum (ZAS) and opsonized zymosan (OZ) were determined. It was observed that chemotactic response of neutrophils to f-Met-Leu-Phe and ZAS was reduced, whereas the chemiluminescence response of both cell types to f-Met-Leu-Phe and zymosan was enhanced...

  14. A Simple and Rapid Flow-Injection Chemiluminescence Method for the Determination of Noscapine with Ru(phen)32+-Ce(4) System

    International Nuclear Information System (INIS)

    Rezaei, B.; Mokhtari, A.; Khayamian, T.

    2007-01-01

    A new flow injection chemiluminescence (CL) system was used for the determination of noscapine. This technique is based on the reduction effect of noscapine on the Ru(phen) 3 3+ , which is produced by reaction between Ru(phen) 3 2+ and acidic Ce(4) solutions, and this rapid reduction produces strong CL. Calibration plots were linear over the range of 3.0x10 -7 -2.0x10 -6 mol L -1 and 2.0x10 -6 -2.0x10 -4 mol L -1 . The CL intensity was so high, that it is able to produce a detection limit of 6.6x10 -8 M noscapine (3σ). The relative standard deviation of 2.0x10 -6 M noscapine was 1.0% (n=10). The proposed method was successfully applied for the flow injection determination of noscapine in cough and Tonin syrup samples. The results of real sample analyses show good recovery percentages (97.3-102.4%). The minimum sampling rate was 100 samples per hour

  15. Dual Delivery of BMP-2 and bFGF from a New Nano-Composite Scaffold, Loaded with Vascular Stents for Large-Size Mandibular Defect Regeneration

    Directory of Open Access Journals (Sweden)

    Hang Zhao

    2013-06-01

    Full Text Available The aim of this study was to investigate the feasibility and advantages of the dual delivery of bone morphogenetic protein-2 (BMP-2 and basic fibroblast growth factor (bFGF from nano-composite scaffolds (PLGA/PCL/nHA loaded with vascular stents (PLCL/Col/nHA for large bone defect regeneration in rabbit mandibles. Thirty-six large bone defects were repaired in rabbits using engineering bone composed of allogeneic bone marrow mesenchymal stem cells (BMSCs, bFGF, BMP-2 and scaffolds composed of PLGA/PCL/nHA loaded with PLCL/Col/nHA. The experiments were divided into six groups: BMSCs/bFGF/BMP-2/scaffold, BMSCs/BMP-2/scaffold, BMSCs/bFGF/scaffold, BMSCs/scaffold, scaffold alone and no treatment. Sodium alginate hydrogel was used as the carrier for BMP-2 and bFGF and its features, including gelling, degradation and controlled release properties, was detected by the determination of gelation and degradation time coupled with a controlled release study of bovine serum albumin (BSA. AlamarBlue assay and alkaline phosphatase (ALP activity were used to evaluate the proliferation and osteogenic differentiation of BMSCs in different groups. X-ray and histological examinations of the samples were performed after 4 and 12 weeks post-implantation to clarify new bone formation in the mandible defects. The results verified that the use of sodium alginate hydrogel as a controlled release carrier has good sustained release ability, and the combined application of bFGF and BMP-2 could significantly promote the proliferation and osteogenic differentiation of BMSCs (p < 0.05 or p < 0.01. In addition, X-ray and histological examinations of the samples exhibited that the dual release group had significantly higher bone formation than the other groups. The above results indicate that the delivery of both growth factors could enhance new bone formation and vascularization compared with delivery of BMP-2 or bFGF alone, and may supply a promising way of repairing large

  16. Fluorosurfactant-capped gold nanoparticles-enhanced chemiluminescence from hydrogen peroxide-hydroxide and hydrogen peroxide-bicarbonate in presence of cobalt(II)

    Science.gov (United States)

    Li, Jinge; Li, Qianqian; Lu, Chao; Zhao, Lixia; Lin, Jin-Ming

    2011-02-01

    Nonionic fluorosurfactant (FSN)-capped gold nanoparticles (GNPs) remain excellently stable at a wider pH range and high ionic strength, which is useful to investigate some CL systems involved in high salt and a strict pH range. In this study, we utilized FSN-capped GNPs of different sizes to distinguish the emitting species from H 2O 2-Co 2+-NaOH and H 2O 2-Co 2+-NaHCO 3 systems. When the pH of FSN-capped gold colloidal solution was adjusted to 10.2 by dropwise addition of 0.05 M NaOH, the CL intensity of H 2O 2-Co 2+-NaHCO 3 system was enhanced 6-fold or 60-fold respectively in the presence of FSN-capped 14 nm or 69 nm GNPs with comparison to H 2O 2-Co 2+-NaOH. The variation of CL spectra and UV-vis spectra, as well as the quenching effect of reactive oxygen species scavengers were studied in detail to understand the CL enhancement mechanisms of FSN-capped GNPs on the two systems. For H 2O 2-Co 2+-NaOH system, the gold(I) complexes intermediate and singlet oxygen dimol species were proposed as the emitting species. The excited states of the carbon dioxide dimers and singlet oxygen dimol species were considered responsible for the light emission of H 2O 2-Co 2+-NaHCO 3 system. To our knowledge, this work is the first time to study the two CL systems simultaneously using nanoparticles.

  17. A UPLC-MS/MS method for analysis of vancomycin in human cerebrospinal fluid and comparison with the chemiluminescence immunoassay.

    Science.gov (United States)

    Mei, Shenghui; Wang, Jiaqing; Zhu, Leting; Chen, Ruiling; Li, Xingang; Chen, Kai; Chen, Guangqiang; Zhou, Jianxin; Wang, Qiang; Zhao, Zhigang

    2017-08-01

    Vancomycin (VCM) is clinically used in treating patients with postoperative intracranial infections. The cerebrospinal fluid (CSF) concentration of VCM varies greatly among patients. To guide the dosage regimens, monitoring of VCM in CSF is needed. However a method for analysis of VCM in human CSF is lacking. An ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for analysis of VCM in human CSF, and the agreement of UPLC-MS/MS and chemiluminescence immunoassay (CLIA) in the analysis of CSF VCM was evaluated. The ion transitions were m/z 725.5 > 144.1 for VCM and m/z 455.2 > 308.2 for methotrexate (internal standard). The agreement between UPLC-MS/MS and CLIA was evaluated by Bland-Altman plot in 179 samples. The calibration range of the UPLC-MS/MS method was 1-400 mg/L. The inaccuracy and imprecision were -0.69-10.80% and  0.98). The 95% limit of agreement of the ratio of CLIA to UPLC-MS/MS was 61.66-107.40%. Further studies are warranted to confirm the results. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Comparative assessment of quality of immunoradiometric assay (IRMA) and chemiluminescence immunometric assay (CHEIMA) for estimation of thyroid stimulating hormone (TSH)

    International Nuclear Information System (INIS)

    Sajid, K.M.

    2009-01-01

    Biological substances like hormones, vitamins and enzymes are found in minute quantities in blood. Their estimation requires very sensitive and specific methods. The most modern method for estimation of thyroid stimulating hormone in serum is non-isotopic enzyme enhanced chemiluminescence immunometric method. In our laboratory immunoradiometric assay is in routine for the last many years. Recently interest has grown to establish non-isotopic techniques in laboratories of PAEC. However, the main requirement to adopt the new procedures is to compare their results, cost and other benefits with the existing method. Immunoassay laboratory of MINAR, therefore, conducted a study to compare the two methods. A total of 173 (males: 34 females: 139 age: between 1 and 65 years) cases of clinically confirmed thyroid status were included in the study. Serum samples of these cases were analyzed by two methods and results were compared by plotting precision profiles, correlation plots and calculating sensitivities and specificities of the methods. As the results in all the samples were not normally distributed Wilcoxon rank sum test was applied to compare the analytical results of two methods. The comparison shows that the results obtained in two methods are not completely similar (p=0.0003293), although analysis of samples in groups shows that some similarity exists between the results of hypo and hyperthyroid patients (p<=0.156 and p<=0.6138). This shows that results obtained in these two methods could sometimes disagree in final diagnosis. Although TSH-CHEIMA is analytically more sensitive than TSH-IRMA the clinical sensitivities and specificities of two methods are not significantly different. TSH-CHEIMA test completes in almost 2 hours whereas TSH-IRMA takes about 6 hours to complete. Comparison of costs shows that TSH-CHIEMA is almost 5 times more expensive than TSH-IRMA. We conclude that the two methods could sometimes disagree but the two techniques have almost same

  19. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    Science.gov (United States)

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  20. Correlation Between Metabolic Syndrome, Periodontitis and Reactive Oxygen Species Production. A Pilot Study.

    Science.gov (United States)

    Patini, Romeo; Gallenzi, Patrizia; Spagnuolo, Gianrico; Cordaro, Massimo; Cantiani, Monica; Amalfitano, Adriana; Arcovito, Alessandro; Callà, Cinzia; Mingrone, Gertrude; Nocca, Giuseppina

    2017-01-01

    Metabolic syndrome (MetS) is associated with an increased risk of periodontitis even if the mechanism is unknown. Since both MetS and periodontitis are characterized by an alteration of inflammation status, the aim of this pilot study was to determine if differences in ROS metabolism of phagocytes isolated from (A) patients with MetS, (B) patients with both MetS and mild periodontitis, (C) healthy subjects and (D) normal weight subjects with mild periodontitis, were present. ROS metabolism was studied by a Chemiluminescence (CL) technique: the system was made up of luminol (100 nmol/L) and cells (1 × 10 5 ) in the presence or absence of stimulus constituted by opsonized zymosan (0.5 mg). The final volume (1.0 mL) was obtained using modified KRP buffer. ROS production was measured at 25°C for 2 h, using an LB 953 luminometer (Berthold, EG & G Co, Germany). All the experiments were performed in triplicate. All results are mean ± standard deviation (SD). The group of means was compared by the analysis of variance "(ANOVA)". A value of p < 0.05 was considered significant. Results showed that basal ROS production (both from PMNs and from PBMs) of groups A, B and D was increased with respect to that obtained from group C ( p <0.05). These results are congruent with literature data, although the actual clinical relevance of the phenomenon remains to be evaluated.

  1. fMLP-Induced IL-8 Release Is Dependent on NADPH Oxidase in Human Neutrophils

    Directory of Open Access Journals (Sweden)

    María A. Hidalgo

    2015-01-01

    Full Text Available N-Formyl-methionyl-leucyl-phenylalanine (fMLP and platelet-activating factor (PAF induce similar intracellular signalling profiles; but only fMLP induces interleukin-8 (IL-8 release and nicotinamide adenine dinucleotide phosphate reduced (NADPH oxidase activity in neutrophils. Because the role of ROS on IL-8 release in neutrophils is until now controversial, we assessed if NADPH oxidase is involved in the IL-8 secretions and PI3K/Akt, MAPK, and NF-κB pathways activity induced by fMLP. Neutrophils were obtained from healthy volunteers. IL-8 was measured by ELISA, IL-8 mRNA by qPCR, and ROS production by luminol-amplified chemiluminescence, reduction of ferricytochrome c, and FACS. Intracellular pH changes were detected by spectrofluorescence. ERK1/2, p38 MAPK, and Akt phosphorylation were analysed by immunoblotting and NF-κB was analysed by immunocytochemistry. Hydroxy-3-methoxyaceto-phenone (HMAP, diphenyleneiodonium (DPI, and siRNA Nox2 reduced the ROS and IL-8 release in neutrophils treated with fMLP. HMAP, DPI, and amiloride (a Na+/H+ exchanger inhibitor inhibited the Akt phosphorylation and did not affect the p38 MAPK and ERK1/2 activity. DPI and HMAP reduced NF-κB translocation induced by fMLP. We showed that IL-8 release induced by fMLP is dependent on NADPH oxidase, and ROS could play a redundant role in cell signalling, ultimately activating the PI3K/Akt and NF-κB pathways in neutrophils.

  2. LC-DAD-MS (ESI+) analysis and antioxidant capacity of crocus sativus petal extracts.

    Science.gov (United States)

    Termentzi, Aikaterini; Kokkalou, Eugene

    2008-04-01

    In this study, various fractions isolated from the petals of Crocus sativus were assessed at first for their phenolic content both qualitatively and quantitatively and secondly for their antioxidant activity. The phytochemical analysis was carried out by LC-DAD-MS (ESI (+)) whereas the antioxidant potential was evaluated by applying two methodologies, the DPPH. radical scavenging activity test and the Co(II)-induced luminol chemiluminescence procedure. According to data obtained from these antioxidant tests, the diethyl ether, ethyl acetate and aqueous fractions demonstrated the strongest antioxidant capacity. Interestingly, the major constituents identified in these fractions correspond to kaempferol, quercetin, naringenin and some flavanone and flavanol derivatives glycosylated and esterified with phenylpropanoic acids. In addition, the presence of some nitrogen-containing substances, as well as other phenolics and phenylpropanoic derivatives was also traced. The identification and structural elucidation of all substances isolated in this study was achieved by both comparing available literature data and by proposed fragmentation mechanisms based on evaluating the LC-DAD-MS (ESI (+)) experimental data. The quantitative analysis data obtained thus far have shown that Crocus sativus petals are a rich source of flavonoids. Such a fact suggests that the good antioxidant capacity detected in the various fractions of Crocus sativus petals could be attributed to the presence of flavonoids, since it is already known that these molecules exert antioxidant capability. The latter, along with the use of Crocus sativus in food and pharmaceutical industry is discussed.

  3. (±)-2-Chloropropionic acid elevates reactive oxygen species formation in human neutrophil granulocytes

    International Nuclear Information System (INIS)

    Aam, B.B.; Fonnum, F.

    2006-01-01

    (±)-2-Chloropropionic acid (2-CPA) is a neurotoxic compound which kills cerebellar granule cells in vivo, and makes cerebellar granule cells in vitro produce reactive oxygen species (ROS). We have studied the effect of 2-CPA on ROS formation in human neutrophil granulocytes in vitro. We found an increased formation of ROS after 2-CPA exposure using three different methods; the fluorescent probe DCFH-DA and the chemiluminescent probes lucigenin and luminol. Four different inhibitors of ROS formation were tested on the cells in combination with 2-CPA to characterize the signalling pathways. The spin-trap s-PBN, the ERK1/2 inhibitor U0126 and the antioxidant Vitamin E inhibited the 2-CPA-induced ROS formation completely, while the mitochondrial transition permeability pore blocker cyclosporine A inhibited the ROS formation partly. We also found that 2-CPA induced an increased nitric oxide production in the cells by using the Griess reagent. The level of reduced glutathione, measured with the DTNB assay, was decreased after exposure to high concentrations of 2-CPA. Western blotting analysis showed that 2-CPA exposure led to an elevated phosphorylation of ERK MAP kinase. This phosphorylation was inhibited by U0126. Based on these experiments it seems like the mechanisms for 2-CPA induced toxicity involves ROS formation and is similar in neutrophil granulocytes as earlier shown in cerebellar granule cells. This also implies that 2-CPA may be immunotoxic

  4. Tailored biodegradable triblock copolymer coatings obtained by MAPLE: a parametric study

    Science.gov (United States)

    Brajnicov, S.; Neacsu, P.; Moldovan, A.; Marascu, V.; Bonciu, A.; Ion, R.; Dinca, V.; Cimpean, A.; Dinescu, M.

    2017-11-01

    Biocompatible and biodegradable coatings with controllable and tailored chemical and physical characteristics (i.e. morphology and roughness) are of great interest in bone related research applications. Within this research direction, in this work, a series of novel biodegradable coatings based on triblock copolymers poly(lactide- co-caprolactone)-block-poly(ethylene-glycol)-block-poly(lactide- co-caprolactone) (PLCL-PEG-PLCL) were obtained by matrix-assisted pulsed laser evaporation (MAPLE) and their morphological characteristics and roughness were modulated by varying target composition and laser fluence. The coatings were used for preliminary in vitro testing with MC3T3-E1 pre-osteoblasts. It was found that for a specific range of fluences, the main functional groups in the MAPLE-deposited thin films, as determined by Fourier transform infrared spectroscopy, are similar to the molecular structures of the initial material. Depending on the deposition parameters, significant changes in morphologies, i.e. material accumulation in the form of droplets, wrinkles, or carpet-like structures were revealed by atomic force microscopy (AFM) and scanning electron microscopy. The optimized coating characteristics were further correlated to MC3T3-E1 pre-osteoblasts response. The ability to control the morphology and to maintain unaltered the chemistry of the deposited material through MAPLE is an important step in creating functional bio-interfaces in the field of biomedical research and tissue engineering.

  5. Suitability of thermoluminescence, chemiluminescence, ESR and viscosity measurements as detection method for the irradiation of medicinal herbs; Eignung von Thermolumineszenz-, Chemilumineszenz-, ESR- und Viskositaetsmessungen zur Identifizierung strahlenbehandelter Arzneidrogen

    Energy Technology Data Exchange (ETDEWEB)

    Schuettler, C.; Gebhardt, G.; Stock, A.; Helle, N.; Boegl, K.W.

    1993-12-31

    Chemiluminescence, electron spin resonance, thermoluminescence and viscosity measurements have been investigated for their suitability as detection method for the irradiation of the medicinal herbs anise seeds (anisi fructus), valerian roots (valerianae radix), redberry leaves (uvae ursi folium), birch leaves (betulae folium), greek hay seeds (foenugraeci semen), cayenne pepper (capsici fructus acer), black-aldertee bark (frangulae cortex), fennel fruits (feoniculi fructus), rose hip shells (cynosbati fructus), coltsfoot (farfarae folium), acorus roots (calami rhizoma), chamomile flowers (matricariae flos), caraway (carvi fructus), lavender flowers (lavandulae flos), linseed (lini semen), lime tree flowers (tiliae flos), St. Mary`s thistle fruit (cardui mariae herba), lemon balm (melissae folium), java tea (orthosiphonis folium), peppermint (menthae piperitae folium), sage leaves (salviae folium), scouring rush (equiseti herba), senna leaves (sennae folium), plantain herbs (plantaginis lanceolata herba), thyme herbs (thymi herba), juniper berries (juniperi fructus), hawthorne herbs (crataegi folium), wheat starch (amylum tritici) and wormwood (absinthii herba). Depending on the herbs, the methods used were more or less suitable. Chemiluminescence measurements showed the smallest differences between untreated and irradiated samples whereas thermoluminescence measurements on isolated minerals from the vegetable drugs gave better results. In some herbs radiation-specific radicals could be identified by ESR spectroscopy. Viscosity measurement is suitable for some herbs as fast and inexpensive method for screening. (orig.) [Deutsch] Die Eignung von Chemilumineszenz-, ESR-, Thermolumineszenz- und Viskositaetsmessungen als Nachweismethode fuer die Behandlung von Arzneidrogen mit ionisierenden Strahlen wurde an Anis, Baldrianwurzel, Baerentraubenblaettern, Birkenblaettern, Bockshornsamen, Cayennepfeffer, Faulbaumrinde, Fenchel, Hagebuttenschalen, Huflattichblaettern

  6. Phage-Mediated Competitive Chemiluminescent Immunoassay for Detecting Cry1Ab Toxin by Using an Anti-Idiotypic Camel Nanobody.

    Science.gov (United States)

    Qiu, Yulou; Li, Pan; Dong, Sa; Zhang, Xiaoshuai; Yang, Qianru; Wang, Yulong; Ge, Jing; Hammock, Bruce D; Zhang, Cunzheng; Liu, Xianjin

    2018-01-31

    Cry toxins have been widely used in genetically modified organisms for pest control, raising public concern regarding their effects on the natural environment and food safety. In this work, a phage-mediated competitive chemiluminescent immunoassay (c-CLIA) was developed for determination of Cry1Ab toxin using anti-idiotypic camel nanobodies. By extracting RNA from camels' peripheral blood lymphocytes, a naive phage-displayed nanobody library was established. Using anti-Cry1Ab toxin monoclonal antibodies (mAbs) against the library for anti-idiotypic antibody screening, four anti-idiotypic nanobodies were selected and confirmed to be specific for anti-Cry1Ab mAb binding. Thereafter, a c-CLIA was developed for detection of Cry1Ab toxin based on anti-idiotypic camel nanobodies and employed for sample testing. The results revealed a half-inhibition concentration of developed assay to be 42.68 ± 2.54 ng/mL, in the linear range of 10.49-307.1 ng/mL. The established method is highly specific for Cry1Ab recognition, with negligible cross-reactivity for other Cry toxins. For spiked cereal samples, the recoveries of Cry1Ab toxin ranged from 77.4% to 127%, with coefficient of variation of less than 9%. This study demonstrated that the competitive format based on phage-displayed anti-idiotypic nanobodies can provide an alternative strategy for Cry toxin detection.

  7. A new chemiluminescence method for determination of dicyandiamide based on the N-bromosuccinimide–merbromin–cetyltrimethylammonium bromide system

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Hua; Tang, Yuhai, E-mail: tyh57@mail.xjtu.edu.cn; Zhang, Guangbin; Wang, Zhongcheng; Gao, Ruixia

    2015-01-15

    A novel and highly sensitive chemiluminescence (CL) method for the determination of dicyandiamide (DCD) has been developed based on the new CL system of N-bromosuccinimide–merbromin–cetyltrimethylammonium bromide in alkaline solution. Experiment conditions were optimized using central composite design-response surface methodology. Under the optimal conditions, the relative CL intensity was linear with the concentration of DCD ranging from 5.0×10{sup −8} g mL{sup −1} to 3.0×10{sup −6} g mL{sup −1}. The detection limit, at the signal-to-noise ratio of 3, was 3.0×10{sup −9} g mL{sup −1}. The relative standard deviation was 1.9% for 11 repeated determinations of 1.0×10{sup −6} g mL{sup −1} DCD. The proposed method was successfully applied to the analyses of DCD in tap water and milk products. And the recoveries were in the range of 87.0–102.3% with relative standard deviation values of 1.2–2.9%. Moreover, the minimum sampling rate was 120 samples h{sup −1}. The possible mechanism of the CL reaction was also discussed. - Highlights: • A novel NBS–merbromin–CTAB–dicyandiamide CL system was proposed. • A CL method for detection of dicyandiamide was developed. • Chemical parameters were optimized using central composite design. • The proposed method is simple, rapid, sensitive, and low-cost.

  8. Wortmannin as Targeted Therapeutic Agent for the Treatment of ...

    African Journals Online (AJOL)

    (7 mg/kg) in DMSO daily intraperitoneally whereas the animals in control groups received an equal volume of DMSO for 21 days after the cancer attained palpable stage. Western blot analysis was carried out using enhanced chemiluminescence reagent while Protean IEF cell unit was used for 1-D electrophoresis. Results: ...

  9. One-step enrichment and chemiluminescence detection of sodium dodecyl benzene sulfonate in river water using Mg-Al-carbonate layered double hydroxides.

    Science.gov (United States)

    Guan, Weijiang; Zhou, Wenjuan; Han, Dongmei; Zhang, Mengchun; Lu, Chao; Lin, Jin-Ming

    2014-03-01

    In this work, Mg-Al CO3-layered double hydroxides (LDHs) were used as adsorbent materials for sodium dodecyl benzene sulfonate (SDBS) in aqueous solutions, the enriched SDBS can be directly detected by IO4(-)-H2O2 chemiluminescence (CL) system. The commonly existing cations cannot be enriched by Mg-Al CO3-LDHs due to the structurally positively charged layers of LDHs, while other adsorbed anionic interferents had no effect on the IO4(-)-H2O2 CL reaction. The corresponding linear regression equation was established in the range of 0.1-10 μM for SDBS. The detection limit at a signal-to-noise (S/N) ratio of 3 for SDBS was 0.08 μM. The relative standard deviation (RSD) for nine repeated measurements of 0.5 μM SDBS was 2.6%. This proposed method has been successfully applied to the determination of SDBS in river water samples. To the best of our knowledge, we have first time coupled the high enrichment capacity of LDHs towards anions with CL detection for analytes. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Tandem sulfur chemiluminescence and flame ionization detection with planar microfluidic devices for the characterization of sulfur compounds in hydrocarbon matrices.

    Science.gov (United States)

    Luong, J; Gras, R; Shellie, R A; Cortes, H J

    2013-07-05

    The detection of sulfur compounds in different hydrocarbon matrices, from light hydrocarbon feedstocks to medium synthetic crude oil feeds provides meaningful information for optimization of refining processes as well as demonstration of compliance with petroleum product specifications. With the incorporation of planar microfluidic devices in a novel chromatographic configuration, sulfur compounds from hydrogen sulfide to alkyl dibenzothiophenes and heavier distributions of sulfur compounds over a wide range of matrices spanning across a boiling point range of more than 650°C can be characterized, using one single analytical configuration in less than 25min. In tandem with a sulfur chemiluminescence detector for sulfur analysis is a flame ionization detector. The flame ionization detector can be used to establish the boiling point range of the sulfur compounds in various hydrocarbon fractions for elemental specific simulated distillation analysis as well as profiling the hydrocarbon matrices for process optimization. Repeatability of less than 3% RSD (n=20) over a range of 0.5-1000 parts per million (v/v) was obtained with a limit of detection of 50 parts per billion and a linear range of 0.5-1000 parts per million with a correlation co-efficient of 0.998. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Beta-1,3-1,6-glucan modulate the non-specific immune response to enhance the survival in the Vibrio alginolyticus infection of Taiwan abalone (Haliotis diversicolor supertexta).

    Science.gov (United States)

    Wu, Yu-Sheng; Tseng, Tzu-Yu; Nan, Fan-Hua

    2016-07-01

    This research aims to investigate the non-specific immune response of Taiwan abalone (Haliotis diversicolor supertexta) which was treated with the beta-1,3-1,6-glucan to be observed in the survival impact after the Vibrio alginolyticus infection. The non-specific immune and physiological response of superoxide anion radical (O2(-)), phenoloxidase (PO), phagocytic index (PI), phagocytic rate (PR) and lucigenin-chemiluminescence for reactive oxygen intermediates (ROIs) were enhanced via in-vitro experiment. In the in-vivo experiment, the observed data presented that the haemolymph lysate supernatant (HLS), superoxide dismutase (SOD), glutamate oxalacetate transaminase (GOT) and glutamate pyruvate transaminase (GPT) were not significant enhanced, but the total haemocyte count (THC), O2(-), PO, phagocytic index (PI), phagocytic ratio (PR) and other parameters of immune were significantly promoted after treated with beta-1,3-1,6-glucan. In the challenge experiment, the survival rates of abalone in the 40 and 80 μl/ml groups of beta-1,3-1,6-glucan were observed from 6.67% up to 33.33% and 36.67% after injection with Vibrio alginolyticus, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Gravitational field-flow fractionation integrated with chemiluminescence detection for a self-standing point-of-care compact device in bioanalysis.

    Science.gov (United States)

    Casolari, S; Roda, B; Mirasoli, M; Zangheri, M; Patrono, D; Reschiglian, P; Roda, A

    2013-01-07

    A "Point-Of-Care-Testing" (POCT) system relies on portable and simply operated self-standing analytical devices. To fulfill diagnostic requirements, the POCT system should provide highly sensitive simultaneous detection of several biomarkers of the pathology of interest (multiplexing) in a short assay time. One of the main unsolved issues in POCT device development is the integration of pre-analytical sample preparation procedures in the miniaturized device. In this work, an integrated POCT system based on gravitational field-flow fractionation (GrFFF) and chemiluminescence (CL) detection is presented for the on-line sample pre-analytical treatment and/or clean-up and analysis of biological fluids. As a proof of principle for the new GrFFF-CL POCT system, the automatic on-line analysis of plasma alkaline phosphatase activity, a biomarker of obstructive liver diseases and bone disorders, starting from whole blood samples was developed. The GrFFF-CL POCT system was able to give quantitative results on blood samples from control and patients with low sample volume (0.5 μL) and reagent consumption, short analysis time (10 minutes), high reproducibility and with a linear range of 50-1400 IU L(-1). The system can be easily applied to on-line prepare plasma from whole blood for other clinical biomarkers and for other assay formats, based on immunoassay or DNA hybridization.

  13. Chemiluminescence of carbon dots induced by diperiodato-nicklate (IV) in alkaline solution and its application to a quenchometric flow-injection assays of paracetamole, L-cysteine and glutathione

    International Nuclear Information System (INIS)

    Dong, Yajuan; Su, Ming; Chen, Peiyun; Sun, Hanwen

    2015-01-01

    Aqueous solutions of carbon dots (C-dots) were prepared by microwave-assisted thermal carbonization of poly(ethylene glycol). They were investigated by transmission electron microscopy, absorption and fluorescence spectra. It is shown that diperiodato-nicklate(IV), a strong oxidant, induces the chemiluminescence (CL) of C-dots in strongly alkaline solution without use of an additional reagent. A mechanism for this reaction is suggested. It is also found that the CL of the system is quenched by paracetamole, L-cysteine and glutathione. Under the optimized conditions, the calibration plot is linear with a correlation coefficient (r) of >0.995. The limits of detection are 90, 8, and 60 µg L -1 for paracetamole, L-cysteine, and glutathione, respectively. Spiked urine and serum samples were analyzed and gave recoveries in the range from 84.38 to 116.0 %, with an RSD of 1.2–2.7 %. (author)

  14. Ultrasound-mediated drug delivery by gas bubbles generated from a chemical reaction.

    Science.gov (United States)

    Lee, Sungmun; Al-Kaabi, Leena; Mawart, Aurélie; Khandoker, Ahsan; Alsafar, Habiba; Jelinek, Herbert F; Khalaf, Kinda; Park, Ji-Ho; Kim, Yeu-Chun

    2018-02-01

    Highly echogenic and ultrasound-responsive microbubbles such as nitrogen and perfluorocarbons have been exploited as ultrasound-mediated drug carriers. Here, we propose an innovative method for drug delivery using microbubbles generated from a chemical reaction. In a novel drug delivery system, luminol encapsulated in folate-conjugated bovine serum albumin nanoparticles (Fol-BSAN) can generate nitrogen gas (N 2 ) by chemical reaction when it reacts with hydrogen peroxide (H 2 O 2 ), one of reactive oxygen species (ROS). ROS plays an important role in the initiation and progression of cancer and elevated ROS have been observed in cancer cells both in vitro and in vivo. High-intensity focussed ultrasound (HIFU) is used to burst the N 2 microbubbles, causing site-specific delivery of anticancer drugs such as methotrexate. In this research, the drug delivery system was optimised by using water-soluble luminol and Mobil Composition of Matter-41 (MCM-41), a mesoporous material, so that the delivery system was sensitive to micromolar concentrations of H 2 O 2 . HIFU increased the drug release from Fol-BSAN by 52.9 ± 2.9% in 10 minutes. The cytotoxicity of methotrexate was enhanced when methotrexate is delivered to MDA-MB-231, a metastatic human breast cancer cell line, using Fol-BSAN with HIFU. We anticipate numerous applications of chemically generated microbubbles for ultrasound-mediated drug delivery.

  15. Aligned poly(L-lactic-co-e-caprolactone) electrospun microfibers and knitted structure: a novel composite scaffold for ligament tissue engineering.

    Science.gov (United States)

    Vaquette, Cédryck; Kahn, Cyril; Frochot, Céline; Nouvel, Cécile; Six, Jean-Luc; De Isla, Natalia; Luo, Li-Hua; Cooper-White, Justin; Rahouadj, Rachid; Wang, Xiong

    2010-09-15

    We developed a novel technique involving knitting and electrospinning to fabricate a composite scaffold for ligament tissue engineering. Knitted structures were coated with poly(L-lactic-co-e-caprolactone) (PLCL) and then placed onto a rotating cylinder and a PLCL solution was electrospun onto the structure. Highly aligned 2-microm-diameter microfibers covered the space between the stitches and adhered to the knitted scaffolds. The stress-strain tensile curves exhibited an initial toe region similar to the tensile behavior of ligaments. Composite scaffolds had an elastic modulus (150 +/- 14 MPa) similar to the modulus of human ligaments. Biological evaluation showed that cells proliferated on the composite scaffolds and they spontaneously orientated along the direction of microfiber alignment. The microfiber architecture also induced a high level of extracellular matrix secretion, which was characterized by immunostaining. We found that cells produced collagen type I and type III, two main components found in ligaments. After 14 days of culture, collagen type III started to form a fibrous network. We fabricated a composite scaffold having the mechanical properties of the knitted structure and the morphological properties of the aligned microfibers. It is difficult to seed a highly macroporous structure with cells, however the technique we developed enabled an easy cell seeding due to presence of the microfiber layer. Therefore, these scaffolds presented attractive properties for a future use in bioreactors for ligament tissue engineering. (c) 2010 Wiley Periodicals, Inc.

  16. Selective determination of semi-volatile thiophene compounds in water by molecularly imprinted polymer thin films with direct headspace gas chromatography sulfur chemiluminescence detection.

    Science.gov (United States)

    Hijazi, Hassan Y; Bottaro, Christina S

    2018-02-26

    Water-compatible molecularly imprinted polymer (MIP) thin films are coupled with headspace gas chromatography sulfur chemiluminescence detection (HS-GC-SCD) to create a new approach for the determination of trace concentrations of thiophene compounds in water samples. Thiophene compounds are persistent, typically petrogenic, organic pollutants of concern due to their potential for biomagnification and bioaccumulation, mutagenicity, and carcinogenicity in terrestrial and aquatic fauna. Identification and quantitation in water, particularly following oil spills, is a priority. Following adsorption of the thiophenes to the MIPs, the MIP-bound analytes are analyzed directly by HS-GC-SCD, with minimal sample manipulation and virtually no organic solvent. Calibration curves of spiked seawater were linear from 5 μg L -1 to 100 μg L -1 and limits of detection (LOD) were in the range of 0.24-0.82 μg L -1 . Low matrix effects were observed in the analysis of thiophene compounds in seawater making the method suitable for use in fresh and saline waters without modification. Acceptable reproducibility was obtained for analysis of thiophene compounds from spiked seawater samples at RSDs ≤7.0% (n = 3).

  17. Comparative antioxidant activity of cultivated and wild Vaccinium species investigated by EPR, human neutrophil burst and COMET assay.

    Science.gov (United States)

    Braga, P C; Antonacci, R; Wang, Y Y; Lattuada, N; Dal Sasso, M; Marabini, L; Fibiani, M; Lo Scalzo, R

    2013-01-01

    The Vaccinium (V.) spp. berries are considered a source of antioxidants, mainly belonging to polyphenols, specifically flavonoids and anthocyanins. Wild genotypes generally contain more antioxidants than cultivated counterparts. So, seven different antioxidants assays on extracts from cultivated and wild Vaccinium berries were performed, to evaluate their difference in terms of bioactivity on oxidative protection and minimum dosage to have a significant action. Four cell-free antioxidant assays (ABTS radical scavenging and electronic paramagnetic resonance using Fremy's salt, superoxide anion and hydroxyl radical), and three assays on human cells (two luminol amplified chemiluminescence, LACL, one on DNA damage, COMET) were used to measure the effects of cultivated blueberry (V. corymbosum) and wild bilberry (V. myrtillus) on the differently induced oxidative stress. Concentrations vs activity patterns were obtained by successive dilutions of extracts in order to identify both EC50 and minimum significant activity (MSA). All the assays (except for the hydroxyl radical scavenging) showed a good relationship mainly with anthocyanin and polyphenol content and the significant greater activity of wild Vaccinium extracts. In fact, LACL data gave an EC50 of 11.8 and an MSA of 5.2 g were calculated as fresh weight dosage in cultivated berries, compared with lower doses in wild berries, EC50 of 5.7 g and MSA of 3.4 g. Wild Vaccinium extracts averaged 3.04 and 2.40 fold more activity than cultivated extracts by EC50 and MSA, respectively. COMET assay confirmed the stronger action on DNA protection in wild samples.

  18. The exploitation of inflammation in photodynamic therapy of pleural cancer (Conference Presentation)

    Science.gov (United States)

    Davis, Richard W.; Miller, Joann; Houser, Cassandra L.; Klampatsa, Astero; Jenkins, Tim; Cengel, Keith A.; Albelda, Steven M.; Busch, Theresa M.

    2017-02-01

    The onset of inflammation is a well-known physiology in tumors treated with photodynamic therapy (PDT). After PDT, the release of danger signals causes an influx of neutrophils, activation of dendritic cells, and an eventual initiation of the adaptive immune response. However, inflammation also lies at a crucial fulcrum for treatment outcome, as it can stimulate the expression of resistance factors. Therefore, effective treatment with PDT requires an understanding of the holistic contribution of inflammation. Within, we outline two means of studying tumor inflammation in the setting of PDT. Experiments are conducted in murine models of mesothelioma, including those that incorporate surgery prior to PDT or pleural propagation of the disease. First, we use a chemiluminescent agent, luminol, to detect the influx of neutrophils by in vivo molecular imaging. This longitudinal approach allows for the repeated non-invasive monitoring of PDT-induced neutrophil influx. Data clearly identify protocol-specific differences in tumor-associated neutrophil activity. Second, we describe the application of cone-beam CT to detect the fibrosis associated with murine orthotropic mesothelioma models. This approach incorporates novel methods in image segmentation to accurately identify diffuse disease in the thoracic cavity. These studies lay the foundation for future research to correlate long-term response with local PDT-induced inflammation. Such methods in monitoring of inflammation or tumor burden will enable characterization of the consequences of combinatorial therapy (e.g., intraoperative PDT). Resulting data will guide the selection of pharmacological agents or molecular imaging techniques that respectively exploit inflammation for therapeutic or monitoring purposes.

  19. Synthesis and evaluation of the potential deleterious effects of ZnO nanomaterials (nanoneedles and nanoflowers) on blood components, including albumin, erythrocytes and human isolated primary neutrophils

    Energy Technology Data Exchange (ETDEWEB)

    Pastrello, Bruna [São Paulo State University (UNESP), Department of Chemistry, Faculty of Sciences (Brazil); Paracatu, Luana Chiquetto [São Paulo State University (UNESP), Department of Clinical Analysis, School of Pharmaceutical Sciences (Brazil); Carvalho Bertozo, Luiza de [São Paulo State University (UNESP), Department of Chemistry, Faculty of Sciences (Brazil); Paino, Iêda Maria Martinez [University of São Paulo (USP), Nanomedicine and Nanotoxicology Group, Physics Institute of São Carlos (IFSC) (Brazil); Lisboa-Filho, Paulo Noronha [São Paulo State University (UNESP), Department of Physics, Faculty of Sciences (Brazil); Ximenes, Valdecir Farias, E-mail: vfximenes@fc.unesp.br [São Paulo State University (UNESP), Department of Chemistry, Faculty of Sciences (Brazil)

    2016-07-15

    The application of zinc oxide (ZnO) nanoparticles in biomaterials has increased significantly in the recent years. Here, we aimed to study the potential deleterious effects of ZnO on blood components, including human serum albumin (HSA), erythrocytes and human isolated primary neutrophils. To test the influence of the morphology of the nanomaterials, ZnO nanoneedles (ZnO-nn) and nanoflowers (ZnO-nf) were synthesized. The zeta potential and mean size of ZnO-nf and ZnO-nn suspensions in phosphate-buffered saline were −10.73 mV and 3.81 nm and −5.27 mV and 18.26 nm, respectively. The incubation of ZnO with HSA did not cause its denaturation as verified by the absence of significant alterations in the intrinsic and extrinsic fluorescence and in the circular dichroism spectrum of the protein. The capacity of HSA as a drug carrier was not affected as verified by employing site I and II fluorescent markers. Neither type of ZnO was able to provoke the activation of neutrophils, as verified by lucigenin- and luminol-dependent chemiluminescence and by the extracellular release of hydrogen peroxide. ZnO-nf, but not ZnO-nn, induced the haemolysis of erythrocytes. In conclusion, our results reinforce the concept that ZnO nanomaterials are relatively safe for usage in biomaterials. A potential exception is the capacity of ZnO-nf to promote the lysis of erythrocytes, a discovery that shows the importance of the morphology in the toxicity of nanoparticles.

  20. [Change of blood antioxidant capacity of experimental animals during nutritional correction under oxidative stress].

    Science.gov (United States)

    Basov, A A; Bykov, I M

    2013-01-01

    The effect of nutritional correction (a diet high in foods with antioxidant content) on blood parameters in laboratory animals with metabolic disorders associated with oxidative stress has been studied. In experimental models of laboratory animals (male rabbits weighing 3.5-4.0 kg, n = 40) with purulent septic diseases it has been demonstrated that the use of nutritive correction (replacement of 100 g of the cereal mixture through day on a mixture of cabbage 50 g, carrots 50 g, beet 25 g, apple 25 g, kiwi 10 g and garnet 10 g per 1 rabbit) is not inferior to its efficiency of glutathione use (2 g per day). The use of these antioxidants in laboratory animals significantly reduced the phenomenon of oxidative stress on the 5th day: blood antioxidant capacity significantly increased by 14.9 and 26.6%, and the area of the flash of luminol-dependent H2O2-induced chemiluminescence of blood plasma reduced by 44.2 and 48.6% in the experimental groups receiving respectively nutritive correction and glutathione. The low-molecula level of blood antioxidant capacity was restored and the balance of the activity of superoxide dismutase (decrease) and catalase (increase) was achieved on the 10th day of the experiment. These figures significantly (p < 0.05) differed from than in the group of animals receiving no antioxidant correction. The latter studied parameters of prooxidant-antioxidant system reached values comparable with those in intact animals (n = 10) only on the 30th day, confirming the advisability of appointing a complex antioxidant therapy.